ML080910071

From kanterella
Jump to navigation Jump to search

Technical Specifications for Amendment No. 195 Nuclear Instrumentation System Permissive Setpoints
ML080910071
Person / Time
Site: Kewaunee Dominion icon.png
Issue date: 03/28/2008
From:
NRC/NRR/ADRO/DORL/LPLIII-1
To:
Milano, P , NRR/DLPM, 415-1457
Shared Package
ML080510411 List:
References
TAC MD5843
Download: ML080910071 (2)


Text

6. Reactor Trip Interlocks Protective instru mentation-settings for-reactor-trip-interlocks-shall -be-as follows: -

A. Prior to exceeding 12.2% of RATED POWER, the low pressurizer pressure trip, high pressurizer level trip, the low reactor coolant flow trips (for both loops), and the turbine trip-reactor trip are made functional.

B. Prior to exceeding 10% of RATED POWER, the single loop loss-of-flow trip is made functional.

7. Other Trips A. Undervoltage > 75% of normal voltage B. Turbine trip C. Manual trip D. Safety injection trip (Refer to Table TS 3.5-1 for trip settings)

Amendment No. 195 TS 2.3-4

TABLE TS 3.5-2 INSTRUMENT OPERATION CONDITIONS FOR REACTOR TRIP NOTES (1) One additional channel may be taken out of service for zero power physics testing.

(2) Deleted (3) When a block condition exists, maintain normal operation.

(4) Underfrequency on the 4-kV buses trips the Reactor Coolant Pump breakers, which in turn trips the reactor when power is above P-7.

Permissive/Interlock Channels Coincidence Setting Limit P-6 Intermediate Range Nuclear Instrument 1 of 2 > 10s% RATED POWER Power Range Nuclear Instrument 3 of 4 < 12.2% RATED POWER P-7 AND i Turbine Impulse Pressure 2 of 2 < 12.2% RATED POWER (a)

P-8  ! Power Range Nuclear Instrument 3 of 4 <10% RATED POWER P-8 Power Range Nuclear Instrument 2 of 4 <7.8% RATEDIPOWER P-1IOoe ag ula ntumn f478 AE! OE (a)Setting Limit is converted to an equivalent turbine impulse pressure Amen dment No. 195 Page 4 of 4