Unit 2 Cycle 14 (U2C14) - 12-Month Steam Generator (SG) Inspection Report
ML073450555
Person / Time
Site: Sequoyah 
Issue date: 12/04/2007
From: James Smith
Tennessee Valley Authority
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
U2C14
Download: ML073450555 (90)


Text

December 4, 2007 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555 Gentlemen:

In the Matter of

)

Docket No. 50-328 Tennessee Valley Authority (TVA)

)

SEQUOYAH NUCLEAR PLANT (SQN) - UNIT 2 CYCLE 14 (U2C14) MONTH STEAM GENERATOR (SG) INSPECTION REPORT In accordance with the requirements of SQN Unit 2 Technical Specification 4.4.5.5.b, TVA is submitting the 12-month report that includes the results of inservice inspections performed on Unit 2 SGs during the U2C14 refueling outage.

There are no commitments contained in this letter.

Please direct questions concerning this issue to me at (423) 843-7170 or J. W. Proffitt at (423) 843-6651.

Sincerely, Original signed by James D. Proffitt for:

James D. Smith Manager, Site Licensing and Industry Affairs Enclosure cc: See page 2

U.S. Nuclear Regulatory Commission Page 2 December 4, 2007 cc (Enclosure):

Mr. Brendan Moroney, Senior Project Manager U.S. Nuclear Regulatory Commission Mail Stop 08G-9a One White Flint North 11555 Rockville Pike Rockville, Maryland 20852-2739

Tennessee Valley Authority Sequoyah Nuclear Plant Unit 2 Cycle 14 Refueling Outage December 2006 12 Month Steam Generator Inspection Report Prepared by:

Verified by:

Approved by:

1 of 88

Table 2 AVB Wear 2 of 88 In accordance with Technical Specification 4.5.5.5, this report documents the results of the Unit 2 Cycle 14 steam generator (SG) tube inservice inspection. The following list includes the examinations that were performed and the extent the tubes were tested.

100-percent Full-length bobbin examination in all 4 SGs.

100-percent hot leg top of tubesheet (HTS) RPC examination in all 4 SGs using a plus point probe +2/-8 (Ref. WCAP-14797) 100-percent of low Row U-bends using a mid range magnetic biased ZETEC

+Point Row 1-4 U-Bend probe 100-percent Row 5 through 8 U-Bend using a MHI probe (or +Point) in all SGs.

100-percent freespan dings greater than or equal to 2 volts (Cycle 13) from HTS to H07 using the +Pt probe 100-percent TSPs H01 to C07 dented greater than or equal to 2 volts (Cycle 13) using the +Pt probe 100-percent of AVB locations with dents with a +Pt probe (Ref. Corp PER 03-000055-000).

100-percent of MBM with dings with a +Pt probe (Ref. Corp PER 03-000023-000).

100-percent of all free-span dents or dings in the U-bend region (any voltage) using the +Pt probe (Ref. Corp. PER 03-000055-000).

100-percent DSIs greater than 1v and less than 2 volts with a +Pt probe during the inspection to add margin for out of ordinary DSI voltage growth.

Westinghouse position supports +Point exams for 1.6 volts and greater, TVA tested 1 volt and greater during U2C12, U2C13, and U2C14.

100 -percent DSIs greater than or equal to 2 volts with a + Pt probe. If + Pt probe detected the indication the tube was plugged.

All identified OXPs were plus point examined.

All new cold leg indications at tube support plate intersections were plus point probe examined.

35,723 examinations were performed during the SQN Unit 2 Cycle 14 Steam Generator Inservice Inspection.

Attached are tables listing location and percent of wall-thickness penetration or eddy current voltage associated with each indication by mechanism and the status of the tube (plugged or in service).

Condition monitoring and operational assessments were performed for each damage mechanism. Performance criteria were met for both the last cycle and the full cycle 15 operation. No tubes exceeded in situ pressure test screening criteria.

Sludge lancing and foreign object search and retrieval was performed on all 4 SGs.

Table 2 AVB Wear 3 of 88 TABLE 1 Nomenclature AVB - Anti-Vibration Bar CA - Crack angle, the circumferential extent of a circumferential crack in degrees CATWSL - Strutural limit crack angle for a 100-percent through wall circumferential crack in degrees C01 - First cold leg tube support plate intersection C02 - Second cold leg tube support plate intersection C03 - Third cold leg tube support plate intersection C04 - Fourth cold leg tube support plate intersection C05 - Fifth cold leg tube support plate intersection C06 - Sixth cold leg tube support plate intersection C07 - Seventh cold tube support plate intersection CTE - Cold leg tube end. (Primary side cold leg face of tubesheet)

CTS - Cold leg top-of-tubesheet. (Secondary side cold leg face of tubesheet)

C/L - Cold Leg H01 - First hot leg tube support plate intersection H02 - Second hot leg tube support plate intersection H03 - Third hot leg tube support plate intersection H04 - Fourth hot leg tube support plate intersection H05 - Fifth hot leg tube support plate intersection H06 - Sixth hot leg tube support plate intersection H07 - Seventh hot leg tube support plate intersection HTE - Hot leg tube end. (Primary side hot leg face of tubesheet)

HTS - Hot leg top-of-tubesheet. (Secondary side cold leg face of tubesheet)

LSTR - Structural length for a 100-percent through-wall axaul crack in inches MHI - Mitsubishi Heavy Industry Array probe ODSCC - Outside Diameter Stress Corrosion Cracking PWSCC - Primary Water Stress Corrosion Cracking RFO - Refuel Outage RPC - Literally Rotating Pancake Coil eddy current probe. This term is also used to describe eddy current probes in which the coil face contacts the tube wall while rotating and being pulled through the tube axially such that the examination path is helical.

SAI - Single Axial Indication SCI - Single Circumferential Indication SG - Steam Generator SVI - Single Volumetric Indication SQN - Sequoyah Nuclear Plant Stab - Tube was stabilized TBP - To-Be-Plugged Analysts determined tube should be plugged (Majority of these were analysis of Axial ODSCC at TSPs bobbin vs +Pt comparison)

TSP - Tube Support Plate TTS - Top of Tubesheet

Table 2 AVB Wear 4 of 88 The indications below were characterized as Anti-Vibration Bar Wear which were detected by bobbin coil. The associated maximum depth and voltage are included.

These indications are plugged at 40-percent through wall (TW) or greater.

SG ROW COL LOCATION

% TW VOLTS CHARACTERIZATION RESOLUTION 1

19 38 AV3+.00 22 0.28 AVB WEAR In Service <40%TW 1

19 38 AV2+.00 35 0.62 AVB WEAR In Service <40%TW 1

27 29 AV3+.11 22 0.44 AVB WEAR In Service <40%TW 1

27 31 AV3+.00 21 0.42 AVB WEAR In Service <40%TW 1

27 31 AV2+.46 19 0.38 AVB WEAR In Service <40%TW 1

32 64 AV2+.09 25 0.64 AVB WEAR In Service <40%TW 1

32 64 AV3+.18 20 0.45 AVB WEAR In Service <40%TW 1

32 64 AV4+.15 16 0.34 AVB WEAR In Service <40%TW 1

36 66 AV3+.06 17 0.38 AVB WEAR In Service <40%TW 1

37 62 AV2+.12 19 0.31 AVB WEAR In Service <40%TW 1

37 62 AV4-.09 19 0.3 AVB WEAR In Service <40%TW 1

37 62 AV3+.00 42 1.25 AVB WEAR PLUGGED 1

39 45 AV2+.00 20 0.35 AVB WEAR In Service <40%TW 2

17 28 AV1+.21 17 0.29 AVB WEAR In Service <40%TW 2

17 28 AV3-.35 31 0.76 AVB WEAR In Service <40%TW 2

17 28 AV2-.23 15 0.24 AVB WEAR In Service <40%TW 2

17 64 AV1+.00 17 0.21 AVB WEAR In Service <40%TW 2

17 64 AV2+.00 21 0.3 AVB WEAR In Service <40%TW 2

17 64 AV3+.00 22 0.32 AVB WEAR In Service <40%TW 2

18 42 AV2+.26 17 0.25 AVB WEAR In Service <40%TW 2

18 72 AV3+.00 15 0.18 AVB WEAR In Service <40%TW 2

19 28 AV1-.42 19 0.35 AVB WEAR In Service <40%TW 2

19 74 AV2-.06 15 0.2 AVB WEAR In Service <40%TW 2

22 41 AV2+.09 24 0.4 AVB WEAR In Service <40%TW 2

23 69 AV3+.09 29 0.55 AVB WEAR In Service <40%TW 2

23 69 AV2+.12 30 0.51 AVB WEAR In Service <40%TW 2

24 61 AV4+.00 16 0.26 AVB WEAR In Service <40%TW 2

24 61 AV2+.30 36 1.01 AVB WEAR In Service <40%TW 2

24 63 AV2+.00 30 0.6 AVB WEAR In Service <40%TW 2

24 64 AV3+.16 24 0.41 AVB WEAR In Service <40%TW 2

24 64 AV1-.11 18 0.28 AVB WEAR In Service <40%TW 2

24 64 AV4+.19 17 0.25 AVB WEAR In Service <40%TW 2

24 64 AV2-.12 23 0.4 AVB WEAR In Service <40%TW 2

24 71 AV3+.00 21 0.32 AVB WEAR In Service <40%TW 2

26 70 AV3+.15 32 0.63 AVB WEAR In Service <40%TW 2

27 43 AV3+.03 25 0.44 AVB WEAR In Service <40%TW 2

27 65 AV1-.22 17 0.26 AVB WEAR In Service <40%TW 2

27 65 AV2-.43 31 0.65 AVB WEAR In Service <40%TW 2

27 65 AV3+.00 38 1.05 AVB WEAR In Service <40%TW 2

29 39 AV2+.55 28 0.49 AVB WEAR In Service <40%TW 2

29 39 AV3-.47 18 0.25 AVB WEAR In Service <40%TW 2

32 46 AV2+.08 6

0.09 AVB WEAR In Service <40%TW 2

32 56 AV3+.00 31 0.66 AVB WEAR In Service <40%TW 2

32 56 AV1+.00 29 0.57 AVB WEAR In Service <40%TW 2

32 56 AV2+.00 30 0.62 AVB WEAR In Service <40%TW 2

32 62 AV3-.21 23 0.31 AVB WEAR In Service <40%TW 2

32 62 AV2+.27 21 0.32 AVB WEAR In Service <40%TW 2

33 62 AV3+.37 19 0.24 AVB WEAR In Service <40%TW 2

33 77 AV3+.12 25 0.32 AVB WEAR In Service <40%TW 2

38 43 AV3+.06 14 0.23 AVB WEAR In Service <40%TW

Table 2 AVB Wear 5 of 88 SG ROW COL LOCATION

% TW VOLTS CHARACTERIZATION RESOLUTION 2

38 46 AV4+.16 20 0.36 AVB WEAR In Service <40%TW 2

38 46 AV3+.11 20 0.37 AVB WEAR In Service <40%TW 2

39 49 AV3+.00 16 0.26 AVB WEAR In Service <40%TW 2

39 49 AV4+.00 15 0.24 AVB WEAR In Service <40%TW 3

18 30 AV2-.20 19 0.38 AVB WEAR In Service <40%TW 3

19 64 AV2+.00 22 0.4 AVB WEAR In Service <40%TW 3

19 64 AV3-.06 25 0.51 AVB WEAR In Service <40%TW 3

23 55 AV3+.18 23 0.32 AVB WEAR In Service <40%TW 3

23 55 AV4+.00 18 0.21 AVB WEAR In Service <40%TW 3

23 55 AV2+.24 15 0.18 AVB WEAR In Service <40%TW 3

28 45 AV1+.00 19 0.35 AVB WEAR In Service <40%TW 3

28 45 AV2+.00 21 0.43 AVB WEAR In Service <40%TW 3

28 45 AV3+.00 19 0.38 AVB WEAR In Service <40%TW 3

32 40 AV3+.00 18 0.31 AVB WEAR In Service <40%TW 3

33 61 AV2+.09 27 0.44 AVB WEAR In Service <40%TW 3

33 61 AV3+.10 21 0.3 AVB WEAR In Service <40%TW 3

34 42 AV4+.00 15 0.28 AVB WEAR In Service <40%TW 3

34 42 AV3+.00 19 0.42 AVB WEAR In Service <40%TW 3

35 39 AV2+.00 15 0.29 AVB WEAR In Service <40%TW 3

35 39 AV1+.00 21 0.43 AVB WEAR In Service <40%TW 3

35 39 AV3+.00 16 0.31 AVB WEAR In Service <40%TW 3

38 40 AV3+.00 17 0.37 AVB WEAR In Service <40%TW 3

38 40 AV4+.00 19 0.42 AVB WEAR In Service <40%TW 3

40 56 AV2-.03 22 0.31 AVB WEAR In Service <40%TW 4

29 67 AV3+.00 34 0.9 AVB WEAR In Service <40%TW 4

29 67 AV2+.00 18 0.32 AVB WEAR In Service <40%TW 4

29 67 AV4+.00 20 0.36 AVB WEAR In Service <40%TW 4

29 67 AV1+.00 19 0.36 AVB WEAR In Service <40%TW 4

32 41 AV3+.20 10 0.13 AVB WEAR In Service <40%TW 4

32 41 AV2+.22 16 0.24 AVB WEAR In Service <40%TW 4

35 55 AV2+.00 19 0.3 AVB WEAR In Service <40%TW 4

35 55 AV1+.41 25 0.46 AVB WEAR In Service <40%TW 4

38 44 AV3+.00 25 0.42 AVB WEAR In Service <40%TW 4

38 47 AV4+.00 24 0.42 AVB WEAR In Service <40%TW 4

38 47 AV3+.00 24 0.41 AVB WEAR In Service <40%TW 4

38 49 AV4+.00 18 0.26 AVB WEAR In Service <40%TW 4

38 49 AV3+.00 25 0.44 AVB WEAR In Service <40%TW 4

38 52 AV4-.12 24 0.41 AVB WEAR In Service <40%TW 4

38 52 AV3+.00 22 0.36 AVB WEAR In Service <40%TW 4

38 65 AV2+.00 15 0.25 AVB WEAR In Service <40%TW 4

38 65 AV1-.03 15 0.25 AVB WEAR In Service <40%TW

Table 3 Cold Leg Thinning 6 of 88 The indications below are Cold Leg Thinning indications. These indications are detected with bobbin coil. The associated voltage and maximum depth are listed. These indications are plugged at 40-percent through wall or greater. Plus point examinations are performed on new cold leg tube support plate intersection indications to confirm that the indication is not crack-like. In addition, old Cold Leg Thinning indications which have changed significantly are examined with a plus point probe. The plus point call VOL indicates a volumetric wall loss of the tube.

SG ROW COL LOCATION INDIC VOLTAGE CHARACTERIZATION RESOLUTION 1

1 1

C01-.06 20 0.35 C/L THINNING In Service <40%TW 1

5 1

C01+.15 29 0.91 C/L THINNING In Service <40%TW 1

7 1

C01+.03 5

0.55 C/L THINNING In Service <40%TW 1

7 1

C01+.25 VOL 0.22 C/L THINNING

+Pt Confirmation 1

10 3

C01+.11 17 0.49 C/L THINNING In Service <40%TW 1

10 3

C01+.28 VOL 0.41 C/L THINNING

+Pt Confirmation 1

11 2

C01+.03 1

0.51 C/L THINNING In Service <40%TW 1

11 2

C01+.29 VOL 0.31 C/L THINNING

+Pt Confirmation 1

11 4

C01-.14 11 0.53 C/L THINNING In Service <40%TW 1

11 4

C01+.06 VOL 0.32 C/L THINNING

+Pt Confirmation 1

16 91 C01+.06 25 0.23 C/L THINNING In Service <40%TW 1

16 91 C01+.11 VOL 0.23 C/L THINNING

+Pt Confirmation 1

17 4

C01+.00

<20 0.23 C/L THINNING In Service <40%TW 1

17 4

C01+.15 VOL 0.19 C/L THINNING

+Pt Confirmation 1

29 84 C01+.09 1

0.67 C/L THINNING In Service <40%TW 1

30 83 C01+.15 34 1.55 C/L THINNING In Service <40%TW 1

31 79 C01-.17

<20 0.46 C/L THINNING In Service <40%TW 1

31 82 C01+.12 1

1.26 C/L THINNING In Service <40%TW 1

34 19 C01+.14 24 1.48 C/L THINNING In Service <40%TW 1

34 79 C03-.09 16 0.66 C/L THINNING In Service <40%TW 1

38 70 C01-.21 16 0.56 C/L THINNING In Service <40%TW 1

42 30 C01+.20

<20 0.65 C/L THINNING In Service <40%TW 1

42 62 C01-.21 16 0.72 C/L THINNING In Service <40%TW 1

43 31 C01+.10 16 1.09 C/L THINNING In Service <40%TW 1

43 32 C01-.08 14 1.19 C/L THINNING In Service <40%TW 1

43 62 C01-.15 10 0.69 C/L THINNING In Service <40%TW 1

44 35 C01-.18 20 0.52 C/L THINNING In Service <40%TW 1

44 36 C01+.13 33 0.68 C/L THINNING In Service <40%TW 1

44 36 C02-.26 35 0.36 C/L THINNING In Service <40%TW 1

44 37 C02-.18 1

0.58 C/L THINNING In Service <40%TW 1

44 37 C02+.01 VOL 0.16 C/L THINNING

+Pt Confirmation 1

44 39 C02-.20 20 1.42 C/L THINNING In Service <40%TW 1

44 45 C02+.05 22 1.30 C/L THINNING In Service <40%TW 1

44 58 C01-.18 11 1.96 C/L THINNING In Service <40%TW 1

44 59 C01-.24

<20 0.48 C/L THINNING In Service <40%TW 1

44 61 C01-.24 23 0.43 C/L THINNING In Service <40%TW 1

45 39 C01+.28

<20 0.61 C/L THINNING In Service <40%TW 1

45 41 C02-.28 18 0.55 C/L THINNING In Service <40%TW 1

45 55 C01-.24

<20 0.28 C/L THINNING In Service <40%TW 1

46 43 C02-.26 17 0.52 C/L THINNING In Service <40%TW 1

46 44 C02-.23 8

0.42 C/L THINNING In Service <40%TW 1

46 50 C01+.21 22 0.96 C/L THINNING In Service <40%TW 1

46 51 C02+.00 1

0.83 C/L THINNING In Service <40%TW 1

46 51 C02+.18 VOL 0.47 C/L THINNING

+Pt Confirmation 1

46 52 C02+.03

<20 0.99 C/L THINNING In Service <40%TW 1

46 53 C01-.21 7

0.84 C/L THINNING In Service <40%TW 2

5 3

C01-.11 1

0.60 C/L THINNING In Service <40%TW

Table 3 Cold Leg Thinning 7 of 88 2

5 3

C01+.02 VOL 0.21 C/L THINNING

+Pt Confirmation 2

5 93 C01-.03 29 0.73 C/L THINNING In Service <40%TW 2

6 94 C01-.28 7

0.64 C/L THINNING In Service <40%TW 2

7 4

C01-.25 15 0.52 C/L THINNING In Service <40%TW 2

7 92 C01-.14 13 0.75 C/L THINNING In Service <40%TW 2

7 94 C01-.17 12 1.19 C/L THINNING In Service <40%TW 2

9 93 C01-.17 1

0.63 C/L THINNING In Service <40%TW 2

9 93 C01-.03 VOL 0.28 C/L THINNING

+Pt Confirmation 2

10 92 C01-.15 8

0.98 C/L THINNING In Service <40%TW 2

11 4

C01-.27 20 0.68 C/L THINNING In Service <40%TW 2

12 4

C01-.18 1

0.71 C/L THINNING In Service <40%TW 2

12 4

C01-.05 VOL 0.17 C/L THINNING

+Pt Confirmation 2

19 6

C01-.03 12 1.25 C/L THINNING In Service <40%TW 2

24 8

C01-.21 28 1.47 C/L THINNING In Service <40%TW 2

24 9

C01+.06 24 0.82 C/L THINNING In Service <40%TW 2

27 85 C01-.17 19 0.49 C/L THINNING In Service <40%TW 2

28 11 C01-.22 25 1.61 C/L THINNING In Service <40%TW 2

28 12 C02-.24 28 1.25 C/L THINNING In Service <40%TW 2

30 16 C02+.17 31 0.45 C/L THINNING In Service <40%TW 2

31 80 C02+.12 1

0.43 C/L THINNING In Service <40%TW 2

32 17 C03-.20 1

0.70 C/L THINNING In Service <40%TW 2

33 16 C02-.12

<20 0.57 C/L THINNING In Service <40%TW 2

33 16 C02+.01 VOL 0.28 C/L THINNING

+Pt Confirmation 2

33 16 C03-.06 58 1.57 C/L THINNING PLUGGED 2

33 16 C03+.00 VOL 0.79 C/L THINNING

+Pt Confirmation 2

33 19 C01-.23 1

1.06 C/L THINNING In Service <40%TW 2

33 19 C01-.08 VOL 0.11 C/L THINNING

+Pt Confirmation 2

33 71 C02-.18

<20 0.32 C/L THINNING In Service <40%TW 2

33 71 C02-.13 VOL 0.25 C/L THINNING

+Pt Confirmation 2

33 74 C02-.12 15 0.83 C/L THINNING In Service <40%TW 2

33 78 C02-.15 34 1.48 C/L THINNING In Service <40%TW 2

34 78 C02-.15 23 0.88 C/L THINNING In Service <40%TW 2

36 18 C01+.14 28 1.76 C/L THINNING In Service <40%TW 2

36 20 C01-.15 26 2.30 C/L THINNING In Service <40%TW 2

36 22 C01-.20

<20 0.45 C/L THINNING In Service <40%TW 2

36 76 C02-.12 38 1.64 C/L THINNING In Service <40%TW 2

38 21 C01-.26 5

0.59 C/L THINNING In Service <40%TW 2

38 22 C03+.00 14 0.68 C/L THINNING In Service <40%TW 2

38 24 C01+.14 32 1.08 C/L THINNING In Service <40%TW 2

38 73 C02-.15 26 0.61 C/L THINNING In Service <40%TW 2

38 74 C02+.24 11 0.72 C/L THINNING In Service <40%TW 2

39 70 C02+.00 35 0.77 C/L THINNING In Service <40%TW 2

39 73 C02+.06 19 0.56 C/L THINNING In Service <40%TW 2

40 24 C01-.09 36 1.45 C/L THINNING In Service <40%TW 2

40 24 C02-.23 21 0.81 C/L THINNING In Service <40%TW 2

40 25 C01+.12 16 0.44 C/L THINNING In Service <40%TW 2

40 25 C01+.22 VOL 0.19 C/L THINNING

+Pt Confirmation 2

40 27 C01-.17 18 0.90 C/L THINNING In Service <40%TW 2

40 67 C02+.18 4

0.93 C/L THINNING In Service <40%TW 2

40 68 C02-.03 30 0.69 C/L THINNING In Service <40%TW 2

40 71 C03-.18 17 0.42 C/L THINNING In Service <40%TW 2

41 26 C02-.32 7

0.71 C/L THINNING In Service <40%TW 2

41 26 C02-.15 VOL 0.29 C/L THINNING

+Pt Confirmation 2

41 29 C01-.06 30 0.64 C/L THINNING In Service <40%TW 2

41 36 C02-.26 6

0.67 C/L THINNING In Service <40%TW 2

41 69 C01+.24 2

0.68 C/L THINNING In Service <40%TW 2

42 28 C01-.26 15 0.56 C/L THINNING In Service <40%TW

Table 3 Cold Leg Thinning 8 of 88 2

42 29 C01+.14 14 0.96 C/L THINNING In Service <40%TW 2

42 36 C01-.26 26 0.64 C/L THINNING In Service <40%TW 2

42 64 C01+.21 19 1.89 C/L THINNING In Service <40%TW 2

42 65 C01+.28 1

0.81 C/L THINNING In Service <40%TW 2

42 65 C01+.31 VOL 0.27 C/L THINNING

+Pt Confirmation 2

42 66 C01+.09 18 0.63 C/L THINNING In Service <40%TW 2

42 67 C01+.22 2

0.53 C/L THINNING In Service <40%TW 2

43 32 C01+.18 34 2.30 C/L THINNING In Service <40%TW 2

43 57 C02+.30 13 0.53 C/L THINNING In Service <40%TW 2

43 58 C02+.27

<20 0.36 C/L THINNING In Service <40%TW 2

43 62 C01+.22

<20 0.70 C/L THINNING In Service <40%TW 2

43 63 C01+.00 37 0.54 C/L THINNING In Service <40%TW 2

44 39 C02-.20 25 1.06 C/L THINNING In Service <40%TW 2

45 37 C02+.23

<20 0.63 C/L THINNING In Service <40%TW 2

45 40 C01-.09 29 0.95 C/L THINNING In Service <40%TW 2

45 43 C01-.29 34 0.51 C/L THINNING In Service <40%TW 2

45 46 C01-.26 6

0.48 C/L THINNING In Service <40%TW 2

45 59 C02-.19 34 1.51 C/L THINNING In Service <40%TW 2

45 59 C02-.05 VOL 0.40 C/L THINNING

+Pt Confirmation 2

45 59 C02+.37 VOL 0.09 C/L THINNING

+Pt Confirmation 2

46 48 C01+.06 12 0.84 C/L THINNING In Service <40%TW 2

46 53 C01+.24 38 0.33 C/L THINNING In Service <40%TW 3

2 1

C01-.06 31 0.36 C/L THINNING In Service <40%TW 3

2 1

C01-.06 VOL 0.28 C/L THINNING

+Pt Confirmation 3

5 1

C01+.06 31 0.80 C/L THINNING In Service <40%TW 3

7 1

C01+.03 31 1.26 C/L THINNING In Service <40%TW 3

7 1

C01+.06 VOL 0.72 C/L THINNING

+Pt Confirmation 3

7 2

C02+.06 1

0.59 C/L THINNING In Service <40%TW 3

10 2

C01+.14 10 1.11 C/L THINNING In Service <40%TW 3

11 90 C01-.21

<20 0.36 C/L THINNING In Service <40%TW 3

11 92 C01-.06 26 1.04 C/L THINNING In Service <40%TW 3

12 3

C01+.06

<20 0.38 C/L THINNING In Service <40%TW 3

17 91 C01-.06 6

0.41 C/L THINNING In Service <40%TW 3

17 91 C01+.03 VOL 0.16 C/L THINNING

+Pt Confirmation 3

24 87 C01-.18 48 1.67 C/L THINNING PLUGGED 3

24 87 C01-.09 VOL 0.59 C/L THINNING

+Pt Confirmation 3

25 9

C01+.03

<20 0.47 C/L THINNING In Service <40%TW 3

27 84 C01-.18 37 1.34 C/L THINNING In Service <40%TW 3

29 83 C01-.06

<20 0.74 C/L THINNING In Service <40%TW 3

30 83 C01-.18 14 1.35 C/L THINNING In Service <40%TW 3

30 83 C02+.03

<20 0.20 C/L THINNING In Service <40%TW 3

31 82 C01+.00 43 1.98 C/L THINNING PLUGGED 3

31 82 C01+.05 VOL 0.58 C/L THINNING

+Pt Confirmation 3

33 78 C01-.09 19 0.79 C/L THINNING In Service <40%TW 3

33 79 C01+.00 38 2.13 C/L THINNING In Service <40%TW 3

34 16 C01-.20 20 0.61 C/L THINNING In Service <40%TW 3

34 16 C02-.26 14 0.49 C/L THINNING In Service <40%TW 3

34 78 C01+.09 11 0.23 C/L THINNING In Service <40%TW 3

35 17 C01-.03

<20 0.44 C/L THINNING In Service <40%TW 3

35 17 C01-.06 VOL 0.38 C/L THINNING

+Pt Confirmation 3

35 17 C02-.11 22 0.48 C/L THINNING In Service <40%TW 3

35 78 C01+.18 1

1.35 C/L THINNING In Service <40%TW 3

36 19 C02+.15

<20 0.27 C/L THINNING In Service <40%TW 3

36 19 C02+.08 VOL 0.18 C/L THINNING

+Pt Confirmation 3

36 74 C01-.12 19 0.62 C/L THINNING In Service <40%TW 3

36 74 C01+.21 21 1.01 C/L THINNING In Service <40%TW 3

36 76 C01-.09 19 0.36 C/L THINNING In Service <40%TW

Table 3 Cold Leg Thinning 9 of 88 3

36 76 C01-.03 VOL 0.20 C/L THINNING

+Pt Confirmation 3

38 74 C01-.06 31 1.10 C/L THINNING In Service <40%TW 3

38 74 C01+.07 VOL 0.55 C/L THINNING

+Pt Confirmation 3

39 68 C01+.09 28 0.83 C/L THINNING In Service <40%TW 3

39 71 C01+.06

<20 0.19 C/L THINNING In Service <40%TW 3

39 71 C01+.39 VOL 0.22 C/L THINNING

+Pt Confirmation 3

39 73 C01-.09 1

0.74 C/L THINNING In Service <40%TW 3

39 73 C01-.02 VOL 0.27 C/L THINNING

+Pt Confirmation 3

40 26 C02-.20 25 0.91 C/L THINNING In Service <40%TW 3

42 28 C01-.03

<20 0.27 C/L THINNING In Service <40%TW 3

42 34 C01+.03

<20 0.27 C/L THINNING In Service <40%TW 3

42 60 C01-.15 17 0.38 C/L THINNING In Service <40%TW 3

43 30 C01-.08

<20 0.81 C/L THINNING In Service <40%TW 3

43 62 C01+.12 8

0.98 C/L THINNING In Service <40%TW 3

44 33 C01+.11 1

0.68 C/L THINNING In Service <40%TW 3

44 34 C02-.14 40 1.87 C/L THINNING PLUGGED 3

44 34 C02+.01 VOL 1.03 C/L THINNING

+Pt Confirmation 3

44 56 C01+.12 9

0.65 C/L THINNING In Service <40%TW 3

44 57 C01-.18 17 0.88 C/L THINNING In Service <40%TW 3

44 60 C01-.12 33 0.51 C/L THINNING In Service <40%TW 3

44 60 C01+.26 VOL 0.44 C/L THINNING

+Pt Confirmation 3

45 40 C03-.26 13 0.51 C/L THINNING In Service <40%TW 3

45 52 C01-.12 16 1.53 C/L THINNING In Service <40%TW 3

45 53 C01+.11 1

0.72 C/L THINNING In Service <40%TW 3

45 58 C01-.12 36 1.01 C/L THINNING In Service <40%TW 3

46 41 C02-.35 34 0.59 C/L THINNING In Service <40%TW 4

6 2

C01-.34

<20 0.29 C/L THINNING In Service <40%TW 4

7 94 C01-.20 18 0.92 C/L THINNING In Service <40%TW 4

11 3

C01-.31 10 1.02 C/L THINNING In Service <40%TW 4

17 91 C01-.08 1

0.69 C/L THINNING In Service <40%TW 4

18 88 C01-.03 3

0.57 C/L THINNING In Service <40%TW 4

19 7

C01-.32

<20 0.65 C/L THINNING In Service <40%TW 4

27 11 C01-.35

<20 0.64 C/L THINNING In Service <40%TW 4

30 15 C01-.28

<20 0.66 C/L THINNING In Service <40%TW 4

31 13 C01-.23 18 2.32 C/L THINNING In Service <40%TW 4

34 76 C02+.28 18 0.69 C/L THINNING In Service <40%TW 4

34 79 C04-.23 1

0.57 C/L THINNING In Service <40%TW 4

37 19 C01-.11 4

0.81 C/L THINNING In Service <40%TW 4

39 22 C02-.14 33 1.15 C/L THINNING In Service <40%TW 4

39 31 C02-.23 14 0.40 C/L THINNING In Service <40%TW 4

39 71 C02+.06

<20 0.42 C/L THINNING In Service <40%TW 4

40 63 C02+.00

<20 0.61 C/L THINNING In Service <40%TW 4

40 71 C02-.18 35 1.47 C/L THINNING In Service <40%TW 4

41 30 C02-.28 15 0.52 C/L THINNING In Service <40%TW 4

41 34 C02-.28 1

0.59 C/L THINNING In Service <40%TW 4

41 58 C02-.14 39 1.33 C/L THINNING In Service <40%TW 4

41 62 C02-.17 28 2.58 C/L THINNING In Service <40%TW 4

41 67 C01-.26

<20 0.54 C/L THINNING In Service <40%TW 4

42 44 C02-.26 24 0.71 C/L THINNING In Service <40%TW 4

43 35 C02+.03 1

0.89 C/L THINNING In Service <40%TW 4

43 47 C02-.29 26 0.32 C/L THINNING In Service <40%TW 4

43 54 C02-.14 27 1.38 C/L THINNING In Service <40%TW 4

44 34 C02-.25 33 2.03 C/L THINNING In Service <40%TW 4

44 38 C02-.25 16 0.82 C/L THINNING In Service <40%TW 4

44 39 C02-.20 1

0.74 C/L THINNING In Service <40%TW 4

44 39 C02-.02 VOL 0.39 C/L THINNING

+Pt Confirmation 4

44 47 C02-.32

<20 0.35 C/L THINNING In Service <40%TW

Table 3 Cold Leg Thinning 10 of 88 4

45 36 C02+.06 1

0.54 C/L THINNING In Service <40%TW 4

45 41 C02-.34

<20 0.27 C/L THINNING In Service <40%TW 4

45 42 C02-.14 25 0.93 C/L THINNING In Service <40%TW 4

45 44 C02-.20 15 0.56 C/L THINNING In Service <40%TW 4

45 45 C02-.29 26 1.50 C/L THINNING In Service <40%TW 4

45 50 C02-.18 34 0.59 C/L THINNING In Service <40%TW 4

45 54 C02+.08 23 0.55 C/L THINNING In Service <40%TW 4

45 55 C01-.22 15 0.40 C/L THINNING In Service <40%TW 4

45 57 C02-.11 39 2.02 C/L THINNING In Service <40%TW 4

46 53 C02+.25 33 0.92 C/L THINNING In Service <40%TW

Table 4 ODSCC Freespan Axial 11 of 88 The indications below are axial (SAI) outside diameter stress corrosion cracking (ODSCC). The SG2R8C2 H01 was dented and therefore detected by the plus point examination. SG3R31C61 was detected by bobbin and confirmed with plus point probe examination. These plus point indications are plugged on detection.

SG ROW COL LOCATION

% TW VOLTS CHARACTERIZATION RESOLUTION 2

8 2

H01+.49 SAI 0.17 ODSCC FREESPAN AXIAL PLUGGED 3

31 61 HTS+47.63 SAI 0.32 ODSCC FREESPAN AXIAL PLUGGED 3

31 61 HTS+47.70 DFI 0.33 ODSCC FREESPAN AXIAL PLUGGED

Table 5 ODSCC Top of Tubesheet Axial 12 of 88 The indications below are axial (SAI) outside diameter stress corrosion cracking (ODSCC) detected by the plus point examinations performed at the hot leg top of the tubesheet (HTS). These indications are plugged on detection.

SG ROW COL LOCATION INDIC VOLTAGE CHARACTERIZATION RESOLUTION 3

26 42 HTS-.07 SAI 0.09 ODSCC HTS AXIAL PLUGGED 4

22 28 HTS-.08 SAI 0.37 ODSCC HTS AXIAL PLUGGED 4

26 33 HTS-.10 SAI 0.22 ODSCC HTS AXIAL PLUGGED

Table 6 ODSCC Top of Tubesheet Circumferential 13 of 88 The indications below are circumferential (SCI) outside diameter stress corrosion cracking (ODSCC) at the hot leg top of the tubesheet. These indications are detected by the plus point examination and are plugged on detection.

SG ROW COL LOCATION INDIC VOLTAGE CHARACTERIZATION RESOLUTION 2

13 67 HTS-.17 SCI 0.17 ODSCC HTS CIRC PLUGGED 2

15 38 HTS+.05 SCI 0.16 ODSCC HTS CIRC PLUGGED 3

11 28 HTS-.01 SCI 0.2 ODSCC HTS CIRC PLUGGED 4

8 71 HTS+.00 SCI 0.25 ODSCC HTS CIRC PLUGGED

Table 7 ODSCC Tube Support Plate Axial 14 of 88 The following indications are axial outside diameter stress corrosion cracking (ODSCC) indications at the tube support plates (TSP). The eddy current call DSI is a bobbin coil call and the call SAI is a plus point probe call. If the bobbin voltage is less than 2 volts, the indication may remain in service via the ODSCC Generic Letter 95-05 Alternate Plugging Criteria (APC). Plus point exams are required for indication 2 volts and greater. At Sequoyah, plus point exams are performed on all indications greater than or equal to 1 volt and the indication is profiled for further analysis. Based on this profile, the indication may be plugged to prevent extreme voltage growth. The details of the ODSCC indications were reported in the required 90-Day Report. The tubes marked Plugged Preventively are the tubes with indications that were determined to have potential for extreme growth.

SG ROW COL LOCATION INDIC VOLTAGE CHARACTERIZATION RESOLUTION 1

2 8

H02+.00 DSI 0.62 ODSCC TSP AXIAL In Service via APC 1

2 10 H01+.09 DSI 0.78 ODSCC TSP AXIAL In Service via APC 1

2 12 H02+.00 DSI 0.6 ODSCC TSP AXIAL In Service via APC 1

2 12 H03-.09 DSI 0.3 ODSCC TSP AXIAL In Service via APC 1

2 13 H01+.00 DSI 0.39 ODSCC TSP AXIAL In Service via APC 1

2 18 H01+.06 DSI 0.33 ODSCC TSP AXIAL In Service via APC 1

3 1

H05+.03 DSI 0.58 ODSCC TSP AXIAL In Service via APC 1

3 15 H01+.09 DSI 1.57 ODSCC TSP AXIAL In Service via APC 1

3 15 H01+.20 SAI 0.15 ODSCC TSP AXIAL In Service via APC 1

3 15 H05+.15 DSI 0.7 ODSCC TSP AXIAL In Service via APC 1

3 16 H01-.06 DSI 0.76 ODSCC TSP AXIAL In Service via APC 1

3 16 H02+.09 DSI 2.36 ODSCC TSP AXIAL PLUGGED 1

3 16 H02+.30 SAI 0.24 ODSCC TSP AXIAL PLUGGED 1

3 16 H02+.31 SAI 0.8 ODSCC TSP AXIAL PLUGGED 1

3 20 H02-.12 DSI 0.4 ODSCC TSP AXIAL In Service via APC 1

3 25 H02+.00 DSI 0.76 ODSCC TSP AXIAL In Service via APC 1

3 25 H02+.19 SAI 0.18 ODSCC TSP AXIAL In Service via APC 1

3 26 H01+.03 DSI 0.68 ODSCC TSP AXIAL In Service via APC 1

3 26 H01+.17 SAI 0.08 ODSCC TSP AXIAL In Service via APC 1

3 27 H01+.00 DSI 0.6 ODSCC TSP AXIAL In Service via APC 1

3 34 H01+.00 DSI 1.03 ODSCC TSP AXIAL In Service via APC 1

3 42 H01+.03 DSI 0.36 ODSCC TSP AXIAL In Service via APC 1

3 46 H01+.03 DSI 1.08 ODSCC TSP AXIAL In Service via APC 1

3 46 H01+.21 SAI 0.36 ODSCC TSP AXIAL In Service via APC 1

3 46 H01+.28 SAI 0.37 ODSCC TSP AXIAL In Service via APC 1

3 46 H02+.12 DSI 0.58 ODSCC TSP AXIAL In Service via APC 1

3 47 H01-.03 DSI 0.5 ODSCC TSP AXIAL In Service via APC 1

3 47 H01+.05 SAI 0.11 ODSCC TSP AXIAL In Service via APC 1

3 47 H02-.03 DSI 0.3 ODSCC TSP AXIAL In Service via APC 1

3 52 H01-.03 DSI 0.53 ODSCC TSP AXIAL In Service via APC 1

3 70 H04+.00 DSI 0.45 ODSCC TSP AXIAL In Service via APC 1

4 6

H02-.03 DSI 0.8 ODSCC TSP AXIAL In Service via APC 1

4 7

H01+.00 DSI 0.8 ODSCC TSP AXIAL In Service via APC 1

4 7

H02+.00 DSI 0.76 ODSCC TSP AXIAL In Service via APC 1

4 8

H01+.00 DSI 0.62 ODSCC TSP AXIAL In Service via APC 1

4 9

H03+.00 DSI 0.41 ODSCC TSP AXIAL In Service via APC 1

4 9

H03+.24 SAI 0.14 ODSCC TSP AXIAL In Service via APC 1

4 11 H01+.00 DSI 0.86 ODSCC TSP AXIAL In Service via APC 1

4 15 H01-.15 DSI 0.94 ODSCC TSP AXIAL In Service via APC 1

4 32 H01-.03 DSI 0.58 ODSCC TSP AXIAL In Service via APC 1

4 40 H02-.06 DSI 0.63 ODSCC TSP AXIAL In Service via APC 1

4 78 H02-.09 DSI 0.48 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 15 of 88 1

4 81 H02-.21 DSI 1.09 ODSCC TSP AXIAL In Service via APC 1

4 81 H02-.02 SAI 0.44 ODSCC TSP AXIAL In Service via APC 1

4 81 H02+.18 SAI 0.22 ODSCC TSP AXIAL In Service via APC 1

5 3

H03+.00 DSI 0.79 ODSCC TSP AXIAL In Service via APC 1

5 7

H01+.03 DSI 0.42 ODSCC TSP AXIAL In Service via APC 1

5 7

H02-.09 DSI 0.44 ODSCC TSP AXIAL In Service via APC 1

5 11 H01+.06 DSI 0.41 ODSCC TSP AXIAL In Service via APC 1

5 13 H02+.00 DSI 0.37 ODSCC TSP AXIAL In Service via APC 1

5 17 H02+.00 DSI 0.46 ODSCC TSP AXIAL In Service via APC 1

5 24 H03-.12 DSI 0.43 ODSCC TSP AXIAL In Service via APC 1

5 26 H01+.03 DSI 0.47 ODSCC TSP AXIAL In Service via APC 1

5 26 H02+.00 DSI 0.71 ODSCC TSP AXIAL In Service via APC 1

5 31 H02-.06 DSI 0.65 ODSCC TSP AXIAL In Service via APC 1

5 32 H01+.00 DSI 0.55 ODSCC TSP AXIAL In Service via APC 1

5 32 H01-.02 SAI 0.15 ODSCC TSP AXIAL In Service via APC 1

5 32 H02-.03 DSI 0.54 ODSCC TSP AXIAL In Service via APC 1

5 33 H01+.00 DSI 0.65 ODSCC TSP AXIAL In Service via APC 1

5 35 H01-.03 DSI 0.8 ODSCC TSP AXIAL In Service via APC 1

5 35 H01+.13 SAI 0.11 ODSCC TSP AXIAL In Service via APC 1

5 35 H03+.06 DSI 0.6 ODSCC TSP AXIAL In Service via APC 1

5 35 H03-.06 SAI 0.11 ODSCC TSP AXIAL In Service via APC 1

5 36 H02+.00 DSI 0.42 ODSCC TSP AXIAL In Service via APC 1

5 43 H02-.06 DSI 0.47 ODSCC TSP AXIAL In Service via APC 1

5 46 H01-.03 DSI 0.9 ODSCC TSP AXIAL In Service via APC 1

5 50 H02+.00 DSI 0.48 ODSCC TSP AXIAL In Service via APC 1

5 50 H02+.11 SAI 0.18 ODSCC TSP AXIAL In Service via APC 1

5 51 H01+.00 DSI 0.32 ODSCC TSP AXIAL In Service via APC 1

5 54 H03-.06 DSI 0.83 ODSCC TSP AXIAL In Service via APC 1

5 72 H02-.03 DSI 0.63 ODSCC TSP AXIAL In Service via APC 1

5 72 H02+.27 SAI 0.14 ODSCC TSP AXIAL In Service via APC 1

5 72 H03-.09 DSI 0.71 ODSCC TSP AXIAL In Service via APC 1

5 72 H03-.11 SAI 0.16 ODSCC TSP AXIAL In Service via APC 1

5 80 H02-.03 DSI 0.67 ODSCC TSP AXIAL In Service via APC 1

5 81 H03+.00 DSI 0.34 ODSCC TSP AXIAL In Service via APC 1

6 2

H01+.09 DSI 0.68 ODSCC TSP AXIAL In Service via APC 1

6 2

H01+.27 SAI 0.3 ODSCC TSP AXIAL In Service via APC 1

6 2

H02-.06 DSI 0.96 ODSCC TSP AXIAL In Service via APC 1

6 2

H03+.03 DSI 1

ODSCC TSP AXIAL In Service via APC 1

6 2

H03+.17 SAI 0.24 ODSCC TSP AXIAL In Service via APC 1

6 3

H01+.00 DSI 0.57 ODSCC TSP AXIAL In Service via APC 1

6 4

H01+.00 DSI 0.72 ODSCC TSP AXIAL In Service via APC 1

6 9

H01+.00 DSI 0.55 ODSCC TSP AXIAL In Service via APC 1

6 14 H01+.03 DSI 0.82 ODSCC TSP AXIAL In Service via APC 1

6 14 H01+.07 SAI 0.1 ODSCC TSP AXIAL In Service via APC 1

6 15 H01+.09 DSI 0.82 ODSCC TSP AXIAL In Service via APC 1

6 15 H01-.15 SAI 0.15 ODSCC TSP AXIAL In Service via APC 1

6 15 H02-.03 DSI 0.66 ODSCC TSP AXIAL In Service via APC 1

6 19 H03+.00 DSI 1

ODSCC TSP AXIAL In Service via APC 1

6 19 H03-.01 SAI 0.15 ODSCC TSP AXIAL In Service via APC 1

6 19 H03+.05 SAI 0.13 ODSCC TSP AXIAL In Service via APC 1

6 21 H01-.12 DSI 1.08 ODSCC TSP AXIAL In Service via APC 1

6 21 H01-.07 SAI 0.53 ODSCC TSP AXIAL In Service via APC 1

6 24 H01+.00 DSI 0.29 ODSCC TSP AXIAL In Service via APC 1

6 24 H03+.00 DSI 0.22 ODSCC TSP AXIAL In Service via APC 1

6 26 H01+.00 DSI 0.47 ODSCC TSP AXIAL In Service via APC 1

6 27 H02+.00 DSI 0.4 ODSCC TSP AXIAL In Service via APC 1

6 29 H01-.09 DSI 0.48 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 16 of 88 1

6 35 H01+.03 DSI 0.32 ODSCC TSP AXIAL In Service via APC 1

6 38 H01-.06 DSI 0.29 ODSCC TSP AXIAL In Service via APC 1

6 45 H01+.00 DSI 0.49 ODSCC TSP AXIAL In Service via APC 1

6 54 H02+.03 DSI 0.67 ODSCC TSP AXIAL In Service via APC 1

6 73 C04+.09 DSI 0.36 ODSCC TSP AXIAL In Service via APC 1

6 91 H02-.03 DSI 0.8 ODSCC TSP AXIAL In Service via APC 1

6 93 H02-.03 DSI 0.81 ODSCC TSP AXIAL In Service via APC 1

6 94 H03+.00 DSI 0.82 ODSCC TSP AXIAL In Service via APC 1

7 3

H05+.00 DSI 0.43 ODSCC TSP AXIAL In Service via APC 1

7 10 H02+.03 DSI 0.35 ODSCC TSP AXIAL In Service via APC 1

7 20 H01+.00 DSI 0.5 ODSCC TSP AXIAL In Service via APC 1

8 3

H01+.00 DSI 0.8 ODSCC TSP AXIAL In Service via APC 1

8 3

H01+.23 SAI 0.14 ODSCC TSP AXIAL In Service via APC 1

8 3

H02+.00 DSI 1.29 ODSCC TSP AXIAL In Service via APC 1

8 3

H02+.00 SAI 0.13 ODSCC TSP AXIAL In Service via APC 1

8 3

H02+.23 SAI 0.14 ODSCC TSP AXIAL In Service via APC 1

8 3

H02+.34 SAI 0.23 ODSCC TSP AXIAL In Service via APC 1

8 3

H03+.00 DSI 0.92 ODSCC TSP AXIAL In Service via APC 1

8 4

H02-.03 DSI 1.15 ODSCC TSP AXIAL In Service via APC 1

8 6

H01-.03 DSI 0.73 ODSCC TSP AXIAL In Service via APC 1

8 6

H01-.07 SAI 0.27 ODSCC TSP AXIAL In Service via APC 1

8 6

H01+.03 SAI 0.16 ODSCC TSP AXIAL In Service via APC 1

8 6

H01+.12 SAI 0.23 ODSCC TSP AXIAL In Service via APC 1

8 12 H01+.00 DSI 0.94 ODSCC TSP AXIAL In Service via APC 1

8 21 H02-.03 DSI 0.62 ODSCC TSP AXIAL In Service via APC 1

8 21 H04+.00 DSI 0.34 ODSCC TSP AXIAL In Service via APC 1

8 33 H01+.00 DSI 0.34 ODSCC TSP AXIAL In Service via APC 1

8 63 H04+.00 DSI 0.27 ODSCC TSP AXIAL In Service via APC 1

9 19 H01-.03 DSI 0.69 ODSCC TSP AXIAL In Service via APC 1

9 25 H02+.09 DSI 0.57 ODSCC TSP AXIAL In Service via APC 1

9 28 H04+.00 DSI 0.37 ODSCC TSP AXIAL In Service via APC 1

9 30 H02+.03 DSI 0.87 ODSCC TSP AXIAL In Service via APC 1

9 32 H01+.00 DSI 0.42 ODSCC TSP AXIAL In Service via APC 1

9 34 H04-.06 DSI 0.68 ODSCC TSP AXIAL In Service via APC 1

9 39 H01+.12 DSI 0.87 ODSCC TSP AXIAL In Service via APC 1

9 41 H02-.03 DSI 0.83 ODSCC TSP AXIAL In Service via APC 1

9 43 H03+.03 DSI 0.62 ODSCC TSP AXIAL In Service via APC 1

9 92 H01+.00 DSI 1.49 ODSCC TSP AXIAL In Service via APC 1

9 92 H01+.26 SAI 0.17 ODSCC TSP AXIAL In Service via APC 1

10 3

H06+.06 DSI 0.97 ODSCC TSP AXIAL In Service via APC 1

10 34 H01+.14 DSI 0.54 ODSCC TSP AXIAL In Service via APC 1

10 37 H01+.00 DSI 0.96 ODSCC TSP AXIAL In Service via APC 1

10 70 H01-.03 DSI 0.54 ODSCC TSP AXIAL In Service via APC 1

10 70 H03-.03 DSI 1.1 ODSCC TSP AXIAL In Service via APC 1

10 75 H01-.03 DSI 0.68 ODSCC TSP AXIAL In Service via APC 1

10 75 H02+.09 DSI 1.06 ODSCC TSP AXIAL In Service via APC 1

10 75 H06-.15 DSI 0.65 ODSCC TSP AXIAL In Service via APC 1

10 77 H01-.03 DSI 0.7 ODSCC TSP AXIAL In Service via APC 1

10 77 H02-.06 DSI 0.58 ODSCC TSP AXIAL In Service via APC 1

10 77 H02+.11 SAI 0.2 ODSCC TSP AXIAL In Service via APC 1

10 77 H04-.09 DSI 1.38 ODSCC TSP AXIAL In Service via APC 1

10 77 H04+.03 SAI 0.15 ODSCC TSP AXIAL In Service via APC 1

10 77 H04+.25 SAI 0.13 ODSCC TSP AXIAL In Service via APC 1

10 78 H02-.15 DSI 0.62 ODSCC TSP AXIAL In Service via APC 1

10 84 H02-.06 DSI 0.69 ODSCC TSP AXIAL In Service via APC 1

11 3

H05+.09 DSI 0.49 ODSCC TSP AXIAL In Service via APC 1

11 3

H06+.03 DSI 0.93 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 17 of 88 1

11 4

H06+.06 DSI 0.69 ODSCC TSP AXIAL In Service via APC 1

11 58 H02+.06 DSI 0.96 ODSCC TSP AXIAL In Service via APC 1

11 61 H02+.03 DSI 0.51 ODSCC TSP AXIAL In Service via APC 1

11 72 H01-.15 DSI 1.91 ODSCC TSP AXIAL PLUGGED-Preventive 1

11 72 H01+.24 SAI 1.61 ODSCC TSP AXIAL PLUGGED-Preventive 1

11 88 H04+.03 DSI 0.25 ODSCC TSP AXIAL In Service via APC 1

11 93 H02-.03 DSI 1.06 ODSCC TSP AXIAL In Service via APC 1

11 93 H02+.29 SAI 0.21 ODSCC TSP AXIAL In Service via APC 1

12 3

H01+.00 DSI 0.48 ODSCC TSP AXIAL In Service via APC 1

12 3

H05-.06 DSI 1.26 ODSCC TSP AXIAL In Service via APC 1

12 3

H06+.06 DSI 0.8 ODSCC TSP AXIAL In Service via APC 1

12 5

H06+.09 DSI 0.39 ODSCC TSP AXIAL In Service via APC 1

12 6

H04+.08 DSI 0.29 ODSCC TSP AXIAL In Service via APC 1

12 10 H01+.14 DSI 0.4 ODSCC TSP AXIAL In Service via APC 1

12 44 H02+.08 DSI 0.29 ODSCC TSP AXIAL In Service via APC 1

12 46 H02+.00 DSI 0.64 ODSCC TSP AXIAL In Service via APC 1

12 48 H02-.12 DSI 0.26 ODSCC TSP AXIAL In Service via APC 1

13 9

H01+.06 DSI 0.78 ODSCC TSP AXIAL In Service via APC 1

13 42 H07+.05 DSI 0.41 ODSCC TSP AXIAL In Service via APC 1

13 54 H03+.24 DSI 0.82 ODSCC TSP AXIAL In Service via APC 1

13 62 H05-.06 DSI 0.32 ODSCC TSP AXIAL In Service via APC 1

13 62 H06-.12 DSI 0.34 ODSCC TSP AXIAL In Service via APC 1

13 89 H02-.09 DSI 0.64 ODSCC TSP AXIAL In Service via APC 1

14 4

H01+.08 DSI 0.51 ODSCC TSP AXIAL In Service via APC 1

14 5

H01+.22 DSI 0.86 ODSCC TSP AXIAL In Service via APC 1

14 5

H02+.03 DSI 1.03 ODSCC TSP AXIAL In Service via APC 1

15 5

H02-.20 DSI 0.83 ODSCC TSP AXIAL In Service via APC 1

15 14 H03+.06 DSI 0.1 ODSCC TSP AXIAL In Service via APC 1

15 18 H01-.06 DSI 0.96 ODSCC TSP AXIAL In Service via APC 1

15 18 H01-.09 SAI 0.16 ODSCC TSP AXIAL In Service via APC 1

15 31 H01+.06 DSI 1.71 ODSCC TSP AXIAL In Service via APC 1

15 31 H01+.16 SAI 0.22 ODSCC TSP AXIAL In Service via APC 1

16 29 H02+.06 DSI 1.08 ODSCC TSP AXIAL In Service via APC 1

16 30 H01+.06 DSI 0.38 ODSCC TSP AXIAL In Service via APC 1

16 86 H04-.06 DSI 0.62 ODSCC TSP AXIAL In Service via APC 1

17 4

H01+.22 DSI 1.44 ODSCC TSP AXIAL In Service via APC 1

17 4

H01+.28 SAI 0.46 ODSCC TSP AXIAL In Service via APC 1

17 4

H01+.31 SAI 0.42 ODSCC TSP AXIAL In Service via APC 1

17 4

H02+.11 DSI 0.5 ODSCC TSP AXIAL In Service via APC 1

17 4

H03+.06 DSI 1.41 ODSCC TSP AXIAL In Service via APC 1

17 4

H03+.24 SAI 0.16 ODSCC TSP AXIAL In Service via APC 1

17 4

H03+.27 SAI 0.15 ODSCC TSP AXIAL In Service via APC 1

17 4

H04+.20 DSI 1.08 ODSCC TSP AXIAL In Service via APC 1

17 4

H04+.00 SAI 0.17 ODSCC TSP AXIAL In Service via APC 1

17 4

H06+.11 DSI 0.55 ODSCC TSP AXIAL In Service via APC 1

17 16 H01+.11 DSI 0.48 ODSCC TSP AXIAL In Service via APC 1

17 20 H01+.00 DSI 0.61 ODSCC TSP AXIAL In Service via APC 1

17 21 H02+.08 DSI 0.21 ODSCC TSP AXIAL In Service via APC 1

17 24 H01+.03 DSI 0.47 ODSCC TSP AXIAL In Service via APC 1

17 33 H02-.14 DSI 1.33 ODSCC TSP AXIAL In Service via APC 1

17 33 H02-.08 SAI 0.13 ODSCC TSP AXIAL In Service via APC 1

17 33 H02-.07 SAI 0.13 ODSCC TSP AXIAL In Service via APC 1

17 33 H02-.05 SAI 0.13 ODSCC TSP AXIAL In Service via APC 1

17 33 H02+.23 SAI 0.15 ODSCC TSP AXIAL In Service via APC 1

17 82 H05-.09 DSI 0.18 ODSCC TSP AXIAL In Service via APC 1

18 7

H03+.08 DSI 0.45 ODSCC TSP AXIAL In Service via APC 1

18 8

H02+.12 DSI 0.65 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 18 of 88 1

18 17 H01+.06 DSI 0.44 ODSCC TSP AXIAL In Service via APC 1

18 19 H02+.20 DSI 1.24 ODSCC TSP AXIAL In Service via APC 1

18 21 H02+.06 DSI 0.15 ODSCC TSP AXIAL In Service via APC 1

18 57 H01+.00 DSI 0.39 ODSCC TSP AXIAL In Service via APC 1

18 82 H02-.06 DSI 0.28 ODSCC TSP AXIAL In Service via APC 1

18 89 H05+.06 DSI 0.76 ODSCC TSP AXIAL In Service via APC 1

19 8

H02+.08 DSI 0.84 ODSCC TSP AXIAL In Service via APC 1

19 8

H05+.14 DSI 0.4 ODSCC TSP AXIAL In Service via APC 1

19 45 H01+.07 DSI 0.49 ODSCC TSP AXIAL In Service via APC 1

19 45 H02+.07 DSI 0.52 ODSCC TSP AXIAL In Service via APC 1

19 51 H01-.03 DSI 0.88 ODSCC TSP AXIAL In Service via APC 1

19 66 H01+.03 DSI 0.85 ODSCC TSP AXIAL In Service via APC 1

19 68 H02-.03 DSI 0.28 ODSCC TSP AXIAL In Service via APC 1

19 74 H02+.00 DSI 0.27 ODSCC TSP AXIAL In Service via APC 1

19 77 H02-.15 DSI 0.86 ODSCC TSP AXIAL In Service via APC 1

19 77 H03-.09 DSI 0.34 ODSCC TSP AXIAL In Service via APC 1

20 9

H02+.06 DSI 0.73 ODSCC TSP AXIAL In Service via APC 1

20 32 H01+.03 DSI 0.35 ODSCC TSP AXIAL In Service via APC 1

20 32 H02+.08 DSI 0.45 ODSCC TSP AXIAL In Service via APC 1

20 51 H01-.09 DSI 0.81 ODSCC TSP AXIAL In Service via APC 1

20 51 H01+.07 SAI 0.18 ODSCC TSP AXIAL In Service via APC 1

20 58 H01+.06 DSI 0.58 ODSCC TSP AXIAL In Service via APC 1

20 65 H02-.18 DSI 1.22 ODSCC TSP AXIAL In Service via APC 1

20 65 H02+.02 SAI 0.41 ODSCC TSP AXIAL In Service via APC 1

20 65 H02+.27 SAI 0.32 ODSCC TSP AXIAL In Service via APC 1

20 67 H01+.03 DSI 0.42 ODSCC TSP AXIAL In Service via APC 1

21 7

H01+.03 DSI 0.97 ODSCC TSP AXIAL In Service via APC 1

21 7

H02+.00 DSI 0.65 ODSCC TSP AXIAL In Service via APC 1

21 8

H01+.17 DSI 0.94 ODSCC TSP AXIAL In Service via APC 1

21 8

H02+.00 DSI 1.01 ODSCC TSP AXIAL In Service via APC 1

21 8

H02+.10 SAI 0.14 ODSCC TSP AXIAL In Service via APC 1

21 8

H02+.12 SAI 0.19 ODSCC TSP AXIAL In Service via APC 1

21 8

H02+.14 SAI 0.16 ODSCC TSP AXIAL In Service via APC 1

21 71 H02-.12 DSI 0.73 ODSCC TSP AXIAL In Service via APC 1

21 73 H01+.03 DSI 0.45 ODSCC TSP AXIAL In Service via APC 1

21 76 H03-.03 DSI 0.25 ODSCC TSP AXIAL In Service via APC 1

21 78 H02-.06 DSI 0.68 ODSCC TSP AXIAL In Service via APC 1

21 83 H02+.03 DSI 0.42 ODSCC TSP AXIAL In Service via APC 1

21 87 H02-.03 DSI 1.23 ODSCC TSP AXIAL In Service via APC 1

21 87 H02+.17 SAI 0.24 ODSCC TSP AXIAL In Service via APC 1

21 87 H02+.18 SAI 0.13 ODSCC TSP AXIAL In Service via APC 1

21 88 H02-.06 DSI 0.8 ODSCC TSP AXIAL In Service via APC 1

22 9

H01+.06 DSI 0.73 ODSCC TSP AXIAL In Service via APC 1

22 10 H02+.08 DSI 0.86 ODSCC TSP AXIAL In Service via APC 1

22 11 H03+.08 DSI 0.71 ODSCC TSP AXIAL In Service via APC 1

22 19 H01+.06 DSI 0.6 ODSCC TSP AXIAL In Service via APC 1

22 21 H01+.06 DSI 0.41 ODSCC TSP AXIAL In Service via APC 1

22 25 H01+.06 DSI 1.2 ODSCC TSP AXIAL In Service via APC 1

22 28 H01+.08 DSI 0.46 ODSCC TSP AXIAL In Service via APC 1

22 31 H01+.06 DSI 0.3 ODSCC TSP AXIAL In Service via APC 1

22 33 H02+.08 DSI 0.83 ODSCC TSP AXIAL In Service via APC 1

22 33 H02+.04 SAI 0.11 ODSCC TSP AXIAL In Service via APC 1

22 33 H02+.20 SAI 0.18 ODSCC TSP AXIAL In Service via APC 1

22 46 H04+.08 DSI 0.22 ODSCC TSP AXIAL In Service via APC 1

22 47 H02+.02 DSI 0.24 ODSCC TSP AXIAL In Service via APC 1

22 48 H01+.00 DSI 1.49 ODSCC TSP AXIAL In Service via APC 1

22 48 H01+.14 SAI 0.17 ODSCC TSP AXIAL In Service via APC 1

22 48 H01+.21 SAI 0.22 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 19 of 88 1

22 48 H01+.23 SAI 0.17 ODSCC TSP AXIAL In Service via APC 1

22 50 H02-.20 DSI 0.75 ODSCC TSP AXIAL In Service via APC 1

22 67 H01+.18 DSI 0.66 ODSCC TSP AXIAL In Service via APC 1

22 68 H02+.03 DSI 0.34 ODSCC TSP AXIAL In Service via APC 1

22 72 H02-.03 DSI 0.51 ODSCC TSP AXIAL In Service via APC 1

23 7

H01+.00 DSI 1.47 ODSCC TSP AXIAL In Service via APC 1

23 7

H01+.28 SAI 0.12 ODSCC TSP AXIAL In Service via APC 1

23 9

H01+.06 DSI 0.26 ODSCC TSP AXIAL In Service via APC 1

23 9

H02+.06 DSI 0.5 ODSCC TSP AXIAL In Service via APC 1

23 11 H02+.14 DSI 0.61 ODSCC TSP AXIAL In Service via APC 1

23 15 H01+.06 DSI 0.49 ODSCC TSP AXIAL In Service via APC 1

23 20 H02+.08 DSI 0.51 ODSCC TSP AXIAL In Service via APC 1

23 31 H01+.17 DSI 0.47 ODSCC TSP AXIAL In Service via APC 1

23 32 H04+.03 DSI 0.33 ODSCC TSP AXIAL In Service via APC 1

23 64 H03+.00 DSI 0.32 ODSCC TSP AXIAL In Service via APC 1

24 9

H01+.08 DSI 0.73 ODSCC TSP AXIAL In Service via APC 1

24 15 H01+.08 DSI 0.44 ODSCC TSP AXIAL In Service via APC 1

24 15 H01+.13 SAI 0.13 ODSCC TSP AXIAL In Service via APC 1

24 17 H02+.06 DSI 0.75 ODSCC TSP AXIAL In Service via APC 1

24 21 H01-.06 DSI 0.41 ODSCC TSP AXIAL In Service via APC 1

24 21 H02+.14 DSI 1.15 ODSCC TSP AXIAL In Service via APC 1

24 21 H02-.02 SAI 0.15 ODSCC TSP AXIAL In Service via APC 1

24 21 H03+.00 DSI 0.8 ODSCC TSP AXIAL In Service via APC 1

24 21 H04+.09 DSI 0.31 ODSCC TSP AXIAL In Service via APC 1

24 22 H01+.11 DSI 0.5 ODSCC TSP AXIAL In Service via APC 1

24 25 H01+.11 DSI 0.46 ODSCC TSP AXIAL In Service via APC 1

24 29 H01+.06 DSI 0.78 ODSCC TSP AXIAL In Service via APC 1

24 29 H02+.06 DSI 0.69 ODSCC TSP AXIAL In Service via APC 1

24 34 H01+.06 DSI 0.54 ODSCC TSP AXIAL In Service via APC 1

24 46 H01+.05 DSI 0.51 ODSCC TSP AXIAL In Service via APC 1

24 60 H01+.03 DSI 0.81 ODSCC TSP AXIAL In Service via APC 1

24 73 H03-.03 DSI 0.58 ODSCC TSP AXIAL In Service via APC 1

25 8

H01+.06 DSI 0.82 ODSCC TSP AXIAL In Service via APC 1

25 14 H02+.08 DSI 0.53 ODSCC TSP AXIAL In Service via APC 1

25 25 H01+.06 DSI 0.77 ODSCC TSP AXIAL In Service via APC 1

25 32 H01+.06 DSI 0.32 ODSCC TSP AXIAL In Service via APC 1

25 37 H01+.08 DSI 0.67 ODSCC TSP AXIAL In Service via APC 1

25 38 H02+.14 DSI 0.93 ODSCC TSP AXIAL In Service via APC 1

25 42 H02-.08 DSI 1.48 ODSCC TSP AXIAL PLUGGED-Preventive 1

25 42 H02+.15 SAI 1.17 ODSCC TSP AXIAL PLUGGED-Preventive 1

25 77 H02+.00 DSI 0.55 ODSCC TSP AXIAL In Service via APC 1

26 11 H01+.11 DSI 0.43 ODSCC TSP AXIAL In Service via APC 1

26 17 H01+.14 DSI 0.65 ODSCC TSP AXIAL In Service via APC 1

26 20 H02+.17 DSI 0.45 ODSCC TSP AXIAL In Service via APC 1

26 25 H04+.06 DSI 0.18 ODSCC TSP AXIAL In Service via APC 1

26 30 H02+.08 DSI 0.6 ODSCC TSP AXIAL In Service via APC 1

26 54 H01-.03 DSI 1.09 ODSCC TSP AXIAL In Service via APC 1

26 54 H01+.12 SAI 0.1 ODSCC TSP AXIAL In Service via APC 1

26 63 C03+.12 DSI 0.33 ODSCC TSP AXIAL In Service via APC 1

26 64 H01+.03 DSI 1.05 ODSCC TSP AXIAL In Service via APC 1

26 64 H01+.19 SAI 0.18 ODSCC TSP AXIAL In Service via APC 1

26 64 H01+.22 SAI 0.12 ODSCC TSP AXIAL In Service via APC 1

26 64 H01+.23 SAI 0.08 ODSCC TSP AXIAL In Service via APC 1

26 68 H03-.03 DSI 0.47 ODSCC TSP AXIAL In Service via APC 1

26 86 H03-.12 DSI 0.39 ODSCC TSP AXIAL In Service via APC 1

27 16 H02+.03 DSI 0.49 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 20 of 88 1

27 18 H01-.05 DSI 0.35 ODSCC TSP AXIAL In Service via APC 1

27 18 H02+.08 DSI 0.79 ODSCC TSP AXIAL In Service via APC 1

27 19 H03+.03 DSI 0.46 ODSCC TSP AXIAL In Service via APC 1

27 21 H02+.03 DSI 0.19 ODSCC TSP AXIAL In Service via APC 1

27 24 H02+.08 DSI 0.39 ODSCC TSP AXIAL In Service via APC 1

27 31 H03+.14 DSI 0.72 ODSCC TSP AXIAL In Service via APC 1

27 48 H01-.06 DSI 1.05 ODSCC TSP AXIAL In Service via APC 1

27 48 H01+.14 SAI 0.11 ODSCC TSP AXIAL In Service via APC 1

27 48 H01+.20 SAI 0.1 ODSCC TSP AXIAL In Service via APC 1

27 48 H01+.24 SAI 0.11 ODSCC TSP AXIAL In Service via APC 1

27 48 H02-.03 DSI 1.38 ODSCC TSP AXIAL In Service via APC 1

27 48 H02+.14 SAI 0.24 ODSCC TSP AXIAL In Service via APC 1

27 48 H02+.15 SAI 0.14 ODSCC TSP AXIAL In Service via APC 1

27 48 H02+.16 SAI 0.14 ODSCC TSP AXIAL In Service via APC 1

27 52 H01-.11 DSI 1.23 ODSCC TSP AXIAL In Service via APC 1

27 52 H01+.09 SAI 0.11 ODSCC TSP AXIAL In Service via APC 1

27 52 H01+.12 SAI 0.42 ODSCC TSP AXIAL In Service via APC 1

27 58 H01+.00 DSI 0.44 ODSCC TSP AXIAL In Service via APC 1

27 60 H01-.03 DSI 1.09 ODSCC TSP AXIAL In Service via APC 1

27 60 H01+.11 SAI 0.41 ODSCC TSP AXIAL In Service via APC 1

27 82 H02+.00 DSI 0.65 ODSCC TSP AXIAL In Service via APC 1

28 10 H02+.06 DSI 0.69 ODSCC TSP AXIAL In Service via APC 1

28 11 H01+.03 DSI 0.67 ODSCC TSP AXIAL In Service via APC 1

28 12 H01+.03 DSI 0.85 ODSCC TSP AXIAL In Service via APC 1

28 16 H01+.08 DSI 0.54 ODSCC TSP AXIAL In Service via APC 1

28 17 H04+.11 DSI 0.76 ODSCC TSP AXIAL In Service via APC 1

28 21 H03+.06 DSI 0.26 ODSCC TSP AXIAL In Service via APC 1

28 26 H02+.03 DSI 0.31 ODSCC TSP AXIAL In Service via APC 1

28 27 H02+.03 DSI 0.6 ODSCC TSP AXIAL In Service via APC 1

28 28 H04+.06 DSI 0.48 ODSCC TSP AXIAL In Service via APC 1

28 28 H06+.12 DSI 0.22 ODSCC TSP AXIAL In Service via APC 1

28 31 H02+.08 DSI 0.72 ODSCC TSP AXIAL In Service via APC 1

28 43 H02+.03 DSI 1.35 ODSCC TSP AXIAL In Service via APC 1

28 43 H02+.08 SAI 0.11 ODSCC TSP AXIAL In Service via APC 1

28 43 H02+.28 SAI 0.33 ODSCC TSP AXIAL In Service via APC 1

28 43 H02+.29 SAI 0.22 ODSCC TSP AXIAL In Service via APC 1

28 45 H02+.00 DSI 1.08 ODSCC TSP AXIAL In Service via APC 1

28 45 H02+.17 SAI 0.12 ODSCC TSP AXIAL In Service via APC 1

28 45 H02+.18 SAI 0.14 ODSCC TSP AXIAL In Service via APC 1

28 46 H02+.00 DSI 0.81 ODSCC TSP AXIAL In Service via APC 1

28 46 H02+.03 SAI 0.13 ODSCC TSP AXIAL In Service via APC 1

28 46 H06+.23 DSI 0.89 ODSCC TSP AXIAL In Service via APC 1

28 50 H02-.03 DSI 1.44 ODSCC TSP AXIAL In Service via APC 1

28 50 H02+.16 SAI 0.22 ODSCC TSP AXIAL In Service via APC 1

28 50 H02+.17 SAI 0.27 ODSCC TSP AXIAL In Service via APC 1

28 56 H02-.09 DSI 0.73 ODSCC TSP AXIAL In Service via APC 1

28 77 H02-.03 DSI 0.69 ODSCC TSP AXIAL In Service via APC 1

28 79 H01-.06 DSI 0.44 ODSCC TSP AXIAL In Service via APC 1

28 79 H02+.00 DSI 0.26 ODSCC TSP AXIAL In Service via APC 1

29 50 H02+.00 DSI 0.67 ODSCC TSP AXIAL In Service via APC 1

29 52 H02+.05 DSI 1.36 ODSCC TSP AXIAL In Service via APC 1

29 52 H02+.15 SAI 0.26 ODSCC TSP AXIAL In Service via APC 1

29 52 H02+.27 SAI 0.31 ODSCC TSP AXIAL In Service via APC 1

29 55 H02-.03 DSI 0.52 ODSCC TSP AXIAL In Service via APC 1

29 56 H03-.03 DSI 0.73 ODSCC TSP AXIAL In Service via APC 1

30 24 H06+.06 DSI 0.44 ODSCC TSP AXIAL In Service via APC 1

30 41 H02-.08 DSI 0.69 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 21 of 88 1

30 49 H02+.00 DSI 0.68 ODSCC TSP AXIAL In Service via APC 1

30 50 H01-.06 DSI 0.47 ODSCC TSP AXIAL In Service via APC 1

30 50 H03+.00 DSI 0.67 ODSCC TSP AXIAL In Service via APC 1

30 62 H02-.06 DSI 0.25 ODSCC TSP AXIAL In Service via APC 1

30 75 H03+.06 DSI 0.41 ODSCC TSP AXIAL In Service via APC 1

30 82 H01+.00 DSI 0.59 ODSCC TSP AXIAL In Service via APC 1

30 82 H02-.06 DSI 0.92 ODSCC TSP AXIAL In Service via APC 1

30 82 H03-.09 DSI 0.46 ODSCC TSP AXIAL In Service via APC 1

31 19 H02+.06 DSI 0.57 ODSCC TSP AXIAL In Service via APC 1

31 19 H03+.03 DSI 0.55 ODSCC TSP AXIAL In Service via APC 1

31 33 H02+.02 DSI 0.37 ODSCC TSP AXIAL In Service via APC 1

31 54 H02-.03 DSI 1.08 ODSCC TSP AXIAL In Service via APC 1

31 54 H02+.04 SAI 0.2 ODSCC TSP AXIAL In Service via APC 1

31 56 H04-.03 DSI 0.26 ODSCC TSP AXIAL In Service via APC 1

31 59 H04-.06 DSI 0.28 ODSCC TSP AXIAL In Service via APC 1

31 62 H03+.00 DSI 0.41 ODSCC TSP AXIAL In Service via APC 1

31 64 H03-.06 DSI 0.42 ODSCC TSP AXIAL In Service via APC 1

31 70 H04-.09 DSI 0.49 ODSCC TSP AXIAL In Service via APC 1

32 17 H02+.23 DSI 1.43 ODSCC TSP AXIAL In Service via APC 1

32 17 H02+.16 SAI 0.2 ODSCC TSP AXIAL In Service via APC 1

32 40 H03+.13 DSI 0.61 ODSCC TSP AXIAL In Service via APC 1

32 42 H01+.07 DSI 0.75 ODSCC TSP AXIAL In Service via APC 1

32 42 H02+.03 DSI 0.67 ODSCC TSP AXIAL In Service via APC 1

32 44 H04+.08 DSI 0.62 ODSCC TSP AXIAL In Service via APC 1

32 48 H02+.05 DSI 0.37 ODSCC TSP AXIAL In Service via APC 1

32 49 H01+.03 DSI 0.32 ODSCC TSP AXIAL In Service via APC 1

32 52 H02+.00 DSI 0.88 ODSCC TSP AXIAL In Service via APC 1

32 53 H01+.13 DSI 0.86 ODSCC TSP AXIAL In Service via APC 1

32 53 H03-.05 DSI 0.96 ODSCC TSP AXIAL In Service via APC 1

32 54 H02-.03 DSI 0.84 ODSCC TSP AXIAL In Service via APC 1

32 54 H02+.04 SAI 0.17 ODSCC TSP AXIAL In Service via APC 1

32 59 H03+.00 DSI 0.65 ODSCC TSP AXIAL In Service via APC 1

32 63 H03+.00 DSI 0.52 ODSCC TSP AXIAL In Service via APC 1

32 65 H04-.06 DSI 0.51 ODSCC TSP AXIAL In Service via APC 1

32 68 H01-.06 DSI 2

ODSCC TSP AXIAL PLUGGED 1

32 68 H01+.30 SAI 1.11 ODSCC TSP AXIAL PLUGGED 1

32 71 H03+.00 DSI 0.58 ODSCC TSP AXIAL In Service via APC 1

32 73 H02-.03 DSI 0.63 ODSCC TSP AXIAL In Service via APC 1

32 74 H03-.03 DSI 1.21 ODSCC TSP AXIAL In Service via APC 1

32 77 H05-.09 DSI 0.34 ODSCC TSP AXIAL In Service via APC 1

32 79 H01-.03 DSI 0.51 ODSCC TSP AXIAL In Service via APC 1

33 17 H03+.23 DSI 1.02 ODSCC TSP AXIAL In Service via APC 1

33 17 H03+.00 SAI 0.1 ODSCC TSP AXIAL In Service via APC 1

33 17 H03+.18 SAI 0.14 ODSCC TSP AXIAL In Service via APC 1

33 27 H04+.09 DSI 0.5 ODSCC TSP AXIAL In Service via APC 1

33 42 H02+.03 DSI 0.32 ODSCC TSP AXIAL In Service via APC 1

33 43 H01+.08 DSI 0.44 ODSCC TSP AXIAL In Service via APC 1

33 50 H02+.08 DSI 0.93 ODSCC TSP AXIAL In Service via APC 1

33 67 H03-.15 DSI 0.44 ODSCC TSP AXIAL In Service via APC 1

33 67 H04-.03 DSI 0.53 ODSCC TSP AXIAL In Service via APC 1

33 71 H02-.06 DSI 0.76 ODSCC TSP AXIAL In Service via APC 1

33 72 H02-.12 DSI 0.39 ODSCC TSP AXIAL In Service via APC 1

33 75 H05+.06 DSI 0.4 ODSCC TSP AXIAL In Service via APC 1

34 22 H02-.03 DSI 0.78 ODSCC TSP AXIAL In Service via APC 1

34 28 H01+.03 DSI 0.36 ODSCC TSP AXIAL In Service via APC 1

34 30 H03+.00 DSI 0.33 ODSCC TSP AXIAL In Service via APC 1

34 74 H04-.03 DSI 0.35 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 22 of 88 1

35 17 H02+.03 DSI 1.16 ODSCC TSP AXIAL In Service via APC 1

35 17 H02+.22 SAI 0.08 ODSCC TSP AXIAL In Service via APC 1

35 17 H02+.30 SAI 0.29 ODSCC TSP AXIAL In Service via APC 1

35 17 H02+.31 SAI 0.12 ODSCC TSP AXIAL In Service via APC 1

35 17 H03+.28 DSI 0.96 ODSCC TSP AXIAL In Service via APC 1

35 17 H06+.06 DSI 0.43 ODSCC TSP AXIAL In Service via APC 1

35 19 H01+.06 DSI 1.1 ODSCC TSP AXIAL In Service via APC 1

35 19 H01-.01 SAI 0.25 ODSCC TSP AXIAL In Service via APC 1

35 19 H03-.06 DSI 0.82 ODSCC TSP AXIAL In Service via APC 1

35 19 H04+.09 DSI 0.49 ODSCC TSP AXIAL In Service via APC 1

35 21 H01+.11 DSI 0.5 ODSCC TSP AXIAL In Service via APC 1

35 21 H02+.08 DSI 0.67 ODSCC TSP AXIAL In Service via APC 1

35 21 H04+.03 DSI 0.45 ODSCC TSP AXIAL In Service via APC 1

35 22 H01+.08 DSI 0.91 ODSCC TSP AXIAL In Service via APC 1

35 22 H02+.03 DSI 0.5 ODSCC TSP AXIAL In Service via APC 1

35 22 H03+.03 DSI 0.94 ODSCC TSP AXIAL In Service via APC 1

35 23 H01+.17 DSI 1.28 ODSCC TSP AXIAL In Service via APC 1

35 23 H01+.21 SAI 0.48 ODSCC TSP AXIAL In Service via APC 1

35 23 H01+.27 SAI 0.41 ODSCC TSP AXIAL In Service via APC 1

35 30 H01-.03 DSI 1.01 ODSCC TSP AXIAL In Service via APC 1

35 30 H01-.04 SAI 0.18 ODSCC TSP AXIAL In Service via APC 1

35 30 H01+.17 SAI 0.29 ODSCC TSP AXIAL In Service via APC 1

35 30 H02+.05 DSI 0.79 ODSCC TSP AXIAL In Service via APC 1

35 30 H03+.00 DSI 0.36 ODSCC TSP AXIAL In Service via APC 1

35 32 H01+.05 DSI 0.53 ODSCC TSP AXIAL In Service via APC 1

35 32 H03+.05 DSI 0.27 ODSCC TSP AXIAL In Service via APC 1

35 33 H02+.10 DSI 0.85 ODSCC TSP AXIAL In Service via APC 1

35 33 H03+.05 DSI 0.56 ODSCC TSP AXIAL In Service via APC 1

35 42 H02+.00 DSI 1.55 ODSCC TSP AXIAL In Service via APC 1

35 42 H02+.10 SAI 0.15 ODSCC TSP AXIAL In Service via APC 1

35 44 H06+.08 DSI 0.23 ODSCC TSP AXIAL In Service via APC 1

35 47 H02+.08 DSI 0.58 ODSCC TSP AXIAL In Service via APC 1

36 25 H04+.06 DSI 0.78 ODSCC TSP AXIAL In Service via APC 1

36 35 H04+.05 DSI 0.63 ODSCC TSP AXIAL In Service via APC 1

36 42 H02-.03 DSI 0.44 ODSCC TSP AXIAL In Service via APC 1

36 47 H02+.13 DSI 0.56 ODSCC TSP AXIAL In Service via APC 1

36 54 H02+.03 DSI 0.39 ODSCC TSP AXIAL In Service via APC 1

36 62 H02-.03 DSI 0.86 ODSCC TSP AXIAL In Service via APC 1

36 62 H03-.06 DSI 0.72 ODSCC TSP AXIAL In Service via APC 1

36 62 H04+.12 DSI 0.71 ODSCC TSP AXIAL In Service via APC 1

37 32 H05+.03 DSI 0.15 ODSCC TSP AXIAL In Service via APC 1

37 40 H01+.03 DSI 0.74 ODSCC TSP AXIAL In Service via APC 1

37 60 H05+.06 DSI 0.24 ODSCC TSP AXIAL In Service via APC 1

37 61 H02-.03 DSI 1.12 ODSCC TSP AXIAL In Service via APC 1

37 61 H02+.05 SAI 0.66 ODSCC TSP AXIAL In Service via APC 1

37 61 H03-.03 DSI 0.49 ODSCC TSP AXIAL In Service via APC 1

38 24 H02-.17 DSI 0.7 ODSCC TSP AXIAL In Service via APC 1

38 40 H01+.10 DSI 0.78 ODSCC TSP AXIAL In Service via APC 1

38 46 H04+.03 DSI 0.52 ODSCC TSP AXIAL In Service via APC 1

38 51 H02+.10 DSI 0.43 ODSCC TSP AXIAL In Service via APC 1

38 63 H02-.06 DSI 0.8 ODSCC TSP AXIAL In Service via APC 1

38 64 H03+.03 DSI 0.47 ODSCC TSP AXIAL In Service via APC 1

38 65 H02-.06 DSI 0.49 ODSCC TSP AXIAL In Service via APC 1

38 65 H04-.09 DSI 0.7 ODSCC TSP AXIAL In Service via APC 1

39 27 H04+.11 DSI 0.52 ODSCC TSP AXIAL In Service via APC 1

39 30 H03+.00 DSI 0.33 ODSCC TSP AXIAL In Service via APC 1

39 30 H05+.00 DSI 0.47 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 23 of 88 1

39 36 H05+.08 DSI 0.69 ODSCC TSP AXIAL In Service via APC 1

39 40 H01+.10 DSI 0.53 ODSCC TSP AXIAL In Service via APC 1

39 46 H01+.05 DSI 0.85 ODSCC TSP AXIAL In Service via APC 1

39 55 C04+.09 DSI 0.21 ODSCC TSP AXIAL In Service via APC 1

40 24 H01+.20 DSI 0.85 ODSCC TSP AXIAL In Service via APC 1

40 24 H01+.00 SAI 0.17 ODSCC TSP AXIAL In Service via APC 1

40 24 H01+.33 SAI 0.46 ODSCC TSP AXIAL In Service via APC 1

40 24 H02+.03 DSI 0.8 ODSCC TSP AXIAL In Service via APC 1

40 25 H01+.03 DSI 0.66 ODSCC TSP AXIAL In Service via APC 1

40 25 H02+.03 DSI 0.74 ODSCC TSP AXIAL In Service via APC 1

40 25 H04+.11 DSI 0.54 ODSCC TSP AXIAL In Service via APC 1

40 26 H01+.12 DSI 0.56 ODSCC TSP AXIAL In Service via APC 1

40 26 H04+.09 DSI 0.61 ODSCC TSP AXIAL In Service via APC 1

40 26 H05+.09 DSI 0.43 ODSCC TSP AXIAL In Service via APC 1

40 27 H02+.06 DSI 0.51 ODSCC TSP AXIAL In Service via APC 1

40 36 H03+.00 DSI 0.6 ODSCC TSP AXIAL In Service via APC 1

40 51 H03-.03 DSI 0.75 ODSCC TSP AXIAL In Service via APC 1

40 70 H03-.09 DSI 0.6 ODSCC TSP AXIAL In Service via APC 1

41 37 H02+.13 DSI 1.15 ODSCC TSP AXIAL In Service via APC 1

42 40 H01+.05 DSI 0.34 ODSCC TSP AXIAL In Service via APC 1

42 40 H02+.03 DSI 0.95 ODSCC TSP AXIAL In Service via APC 1

42 40 H07-.13 DSI 0.39 ODSCC TSP AXIAL In Service via APC 1

42 49 H02+.05 DSI 0.86 ODSCC TSP AXIAL In Service via APC 1

42 62 H01-.03 DSI 0.62 ODSCC TSP AXIAL In Service via APC 1

43 38 H01+.10 DSI 1.15 ODSCC TSP AXIAL In Service via APC 1

43 46 H04+.11 DSI 0.6 ODSCC TSP AXIAL In Service via APC 1

43 59 H01-.09 DSI 1.09 ODSCC TSP AXIAL In Service via APC 1

43 59 H01+.16 SAI 0.1 ODSCC TSP AXIAL In Service via APC 1

44 37 H02-.03 DSI 1.5 ODSCC TSP AXIAL In Service via APC 1

44 40 H02+.10 DSI 0.55 ODSCC TSP AXIAL In Service via APC 1

44 42 H02+.08 DSI 0.87 ODSCC TSP AXIAL In Service via APC 1

44 45 H02+.03 DSI 0.99 ODSCC TSP AXIAL In Service via APC 1

44 50 H02+.05 DSI 0.71 ODSCC TSP AXIAL In Service via APC 1

44 56 H03-.03 DSI 0.99 ODSCC TSP AXIAL In Service via APC 1

44 57 H01-.06 DSI 1.01 ODSCC TSP AXIAL In Service via APC 1

45 37 H02+.03 DSI 0.67 ODSCC TSP AXIAL In Service via APC 1

45 39 H01+.20 DSI 0.58 ODSCC TSP AXIAL In Service via APC 1

45 39 H06+.13 DSI 1.07 ODSCC TSP AXIAL In Service via APC 1

45 44 H03+.08 DSI 1.52 ODSCC TSP AXIAL In Service via APC 1

45 47 H02+.13 DSI 0.46 ODSCC TSP AXIAL In Service via APC 1

45 47 H03+.13 DSI 0.85 ODSCC TSP AXIAL In Service via APC 1

45 47 H04+.11 DSI 0.75 ODSCC TSP AXIAL In Service via APC 1

45 49 H02+.10 DSI 0.68 ODSCC TSP AXIAL In Service via APC 1

45 51 H02+.08 DSI 1.07 ODSCC TSP AXIAL In Service via APC 1

45 51 H02+.21 SAI 0.1 ODSCC TSP AXIAL In Service via APC 1

45 51 H02+.23 SAI 0.11 ODSCC TSP AXIAL In Service via APC 1

45 55 H03-.12 DSI 0.33 ODSCC TSP AXIAL In Service via APC 1

46 41 H03+.15 DSI 0.67 ODSCC TSP AXIAL In Service via APC 1

46 50 H03+.05 DSI 0.87 ODSCC TSP AXIAL In Service via APC 2

1 76 H01-.06 DSI 0.79 ODSCC TSP AXIAL In Service via APC 2

2 2

H02+.00 DSI 0.6 ODSCC TSP AXIAL In Service via APC 2

2 2

H02+.20 SAI 0.15 ODSCC TSP AXIAL In Service via APC 2

2 2

H05+.03 DSI 0.25 ODSCC TSP AXIAL In Service via APC 2

2 14 H02+.06 DSI 0.47 ODSCC TSP AXIAL In Service via APC 2

2 22 H02+.03 DSI 0.38 ODSCC TSP AXIAL In Service via APC 2

2 30 H02+.00 DSI 0.4 ODSCC TSP AXIAL In Service via APC 2

2 37 H02+.09 DSI 0.55 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 24 of 88 2

2 42 H01+.00 DSI 0.41 ODSCC TSP AXIAL In Service via APC 2

2 43 H02+.11 DSI 0.98 ODSCC TSP AXIAL In Service via APC 2

2 43 H02+.20 SAI 0.24 ODSCC TSP AXIAL In Service via APC 2

2 45 H02-.03 DSI 1.08 ODSCC TSP AXIAL In Service via APC 2

2 46 H02+.22 DSI 0.67 ODSCC TSP AXIAL In Service via APC 2

2 47 H05+.00 DSI 0.43 ODSCC TSP AXIAL In Service via APC 2

2 48 H01-.03 DSI 0.45 ODSCC TSP AXIAL In Service via APC 2

2 49 H01+.06 DSI 0.25 ODSCC TSP AXIAL In Service via APC 2

2 49 H02-.06 DSI 0.5 ODSCC TSP AXIAL In Service via APC 2

2 50 H02-.06 DSI 0.68 ODSCC TSP AXIAL In Service via APC 2

2 55 H01+.00 DSI 0.48 ODSCC TSP AXIAL In Service via APC 2

2 55 H02+.00 DSI 0.85 ODSCC TSP AXIAL In Service via APC 2

2 58 H01-.03 DSI 1.17 ODSCC TSP AXIAL In Service via APC 2

2 58 H01+.10 SAI 0.13 ODSCC TSP AXIAL In Service via APC 2

2 58 H01+.30 SAI 0.19 ODSCC TSP AXIAL In Service via APC 2

2 58 H02+.00 DSI 1.61 ODSCC TSP AXIAL In Service via APC 2

2 58 H02+.08 SAI 0.14 ODSCC TSP AXIAL In Service via APC 2

2 58 H02+.13 SAI 0.12 ODSCC TSP AXIAL In Service via APC 2

2 58 H02+.28 SAI 0.33 ODSCC TSP AXIAL In Service via APC 2

2 61 H02+.00 DSI 1.32 ODSCC TSP AXIAL In Service via APC 2

2 61 H02+.02 SAI 0.11 ODSCC TSP AXIAL In Service via APC 2

2 61 H02+.20 SAI 0.13 ODSCC TSP AXIAL In Service via APC 2

2 61 H02+.24 SAI 0.15 ODSCC TSP AXIAL In Service via APC 2

2 62 H02+.00 DSI 0.7 ODSCC TSP AXIAL In Service via APC 2

2 63 H04+.00 DSI 0.6 ODSCC TSP AXIAL In Service via APC 2

2 66 H02+.00 DSI 1.15 ODSCC TSP AXIAL In Service via APC 2

2 70 H02-.03 DSI 0.69 ODSCC TSP AXIAL In Service via APC 2

2 73 H01-.12 DSI 0.67 ODSCC TSP AXIAL In Service via APC 2

2 73 H02+.00 DSI 0.85 ODSCC TSP AXIAL In Service via APC 2

2 76 H02-.15 DSI 0.87 ODSCC TSP AXIAL In Service via APC 2

2 77 H01-.06 DSI 0.28 ODSCC TSP AXIAL In Service via APC 2

2 82 H04-.12 DSI 1.45 ODSCC TSP AXIAL In Service via APC 2

2 82 H04+.05 SAI 0.12 ODSCC TSP AXIAL In Service via APC 2

2 82 H04+.20 SAI 0.13 ODSCC TSP AXIAL In Service via APC 2

2 83 H01-.15 DSI 0.68 ODSCC TSP AXIAL In Service via APC 2

2 83 H04+.06 DSI 0.91 ODSCC TSP AXIAL In Service via APC 2

2 84 H01+.03 DSI 0.57 ODSCC TSP AXIAL In Service via APC 2

2 85 H01-.09 DSI 0.98 ODSCC TSP AXIAL In Service via APC 2

2 85 H02+.00 DSI 0.94 ODSCC TSP AXIAL In Service via APC 2

2 85 H04-.03 DSI 0.52 ODSCC TSP AXIAL In Service via APC 2

2 87 H01+.03 DSI 1.2 ODSCC TSP AXIAL In Service via APC 2

2 87 H01+.19 SAI 0.16 ODSCC TSP AXIAL In Service via APC 2

2 87 H01+.27 SAI 0.16 ODSCC TSP AXIAL In Service via APC 2

2 88 H01-.06 DSI 0.87 ODSCC TSP AXIAL In Service via APC 2

2 88 H02-.03 DSI 1.19 ODSCC TSP AXIAL In Service via APC 2

2 88 H02+.10 SAI 0.1 ODSCC TSP AXIAL In Service via APC 2

2 88 H02+.21 SAI 0.39 ODSCC TSP AXIAL In Service via APC 2

2 88 H03+.00 DSI 0.38 ODSCC TSP AXIAL In Service via APC 2

2 88 H06+.03 DSI 0.69 ODSCC TSP AXIAL In Service via APC 2

2 90 H01+.09 DSI 0.33 ODSCC TSP AXIAL In Service via APC 2

2 94 H01-.06 DSI 0.62 ODSCC TSP AXIAL In Service via APC 2

2 94 H02-.06 DSI 0.81 ODSCC TSP AXIAL In Service via APC 2

3 5

H02-.03 DSI 0.66 ODSCC TSP AXIAL In Service via APC 2

3 5

H03+.20 DSI 1.61 ODSCC TSP AXIAL PLUGGED 2

3 5

H03+.30 SAI 0.19 ODSCC TSP AXIAL PLUGGED 2

3 5

H04-.06 DSI 0.69 ODSCC TSP AXIAL In Service via APC 2

3 12 H04+.03 DSI 0.21 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 25 of 88 2

3 16 H02-.09 DSI 0.41 ODSCC TSP AXIAL In Service via APC 2

3 17 H02-.06 DSI 0.27 ODSCC TSP AXIAL In Service via APC 2

3 30 H02-.06 DSI 0.63 ODSCC TSP AXIAL In Service via APC 2

3 31 H01+.06 DSI 0.38 ODSCC TSP AXIAL In Service via APC 2

3 31 H02-.03 DSI 0.44 ODSCC TSP AXIAL In Service via APC 2

3 37 H02-.03 DSI 1.03 ODSCC TSP AXIAL In Service via APC 2

3 38 H05+.00 DSI 0.17 ODSCC TSP AXIAL In Service via APC 2

3 42 H02+.00 DSI 1.73 ODSCC TSP AXIAL In Service via APC 2

3 42 H02+.19 SAI 0.1 ODSCC TSP AXIAL In Service via APC 2

3 42 H02+.22 SAI 0.27 ODSCC TSP AXIAL In Service via APC 2

3 42 H04+.00 DSI 0.6 ODSCC TSP AXIAL In Service via APC 2

3 49 H02-.12 DSI 0.73 ODSCC TSP AXIAL In Service via APC 2

3 51 H02-.03 DSI 1.15 ODSCC TSP AXIAL In Service via APC 2

3 61 H02+.00 DSI 1.02 ODSCC TSP AXIAL In Service via APC 2

3 61 H02+.11 SAI 0.14 ODSCC TSP AXIAL In Service via APC 2

3 61 H02+.34 SAI 0.16 ODSCC TSP AXIAL In Service via APC 2

3 62 H02-.03 DSI 0.33 ODSCC TSP AXIAL In Service via APC 2

3 72 H01+.03 DSI 0.82 ODSCC TSP AXIAL In Service via APC 2

3 72 H03+.00 DSI 0.8 ODSCC TSP AXIAL In Service via APC 2

3 76 H02+.15 DSI 0.82 ODSCC TSP AXIAL In Service via APC 2

3 88 H02+.09 DSI 0.59 ODSCC TSP AXIAL In Service via APC 2

3 92 H01+.09 DSI 0.38 ODSCC TSP AXIAL In Service via APC 2

4 1

H02-.03 DSI 0.45 ODSCC TSP AXIAL In Service via APC 2

4 1

H04-.06 DSI 0.44 ODSCC TSP AXIAL In Service via APC 2

4 22 H02+.09 DSI 0.27 ODSCC TSP AXIAL In Service via APC 2

4 26 H02+.06 DSI 0.95 ODSCC TSP AXIAL In Service via APC 2

4 27 H02+.03 DSI 0.7 ODSCC TSP AXIAL In Service via APC 2

4 29 H04+.00 DSI 0.3 ODSCC TSP AXIAL In Service via APC 2

4 36 H01-.03 DSI 1.13 ODSCC TSP AXIAL In Service via APC 2

4 36 H01+.11 SAI 0.25 ODSCC TSP AXIAL In Service via APC 2

4 36 H01+.28 SAI 0.13 ODSCC TSP AXIAL In Service via APC 2

4 45 H02+.00 DSI 0.92 ODSCC TSP AXIAL In Service via APC 2

4 50 H01+.03 DSI 0.83 ODSCC TSP AXIAL In Service via APC 2

4 50 H02+.03 DSI 0.3 ODSCC TSP AXIAL In Service via APC 2

4 54 H02-.12 DSI 0.82 ODSCC TSP AXIAL In Service via APC 2

4 56 H02+.14 DSI 1.08 ODSCC TSP AXIAL In Service via APC 2

4 56 H02+.09 SAI 0.15 ODSCC TSP AXIAL In Service via APC 2

4 56 H02+.23 SAI 0.13 ODSCC TSP AXIAL In Service via APC 2

4 57 H01-.09 DSI 0.47 ODSCC TSP AXIAL In Service via APC 2

4 57 H04+.00 DSI 0.25 ODSCC TSP AXIAL In Service via APC 2

4 59 H01-.06 DSI 1.12 ODSCC TSP AXIAL In Service via APC 2

4 59 H01+.00 SAI 0.12 ODSCC TSP AXIAL In Service via APC 2

4 59 H01+.23 SAI 0.18 ODSCC TSP AXIAL In Service via APC 2

4 59 H02+.00 DSI 1.36 ODSCC TSP AXIAL In Service via APC 2

4 59 H02-.08 SAI 0.1 ODSCC TSP AXIAL In Service via APC 2

4 61 H04+.00 DSI 0.78 ODSCC TSP AXIAL In Service via APC 2

4 64 H01+.00 DSI 0.72 ODSCC TSP AXIAL In Service via APC 2

4 91 H01+.00 DSI 1.3 ODSCC TSP AXIAL In Service via APC 2

4 91 H01+.16 SAI 0.1 ODSCC TSP AXIAL In Service via APC 2

4 92 H03-.06 DSI 0.41 ODSCC TSP AXIAL In Service via APC 2

4 92 H04+.00 DSI 0.46 ODSCC TSP AXIAL In Service via APC 2

4 92 H05+.03 DSI 0.62 ODSCC TSP AXIAL In Service via APC 2

4 94 H01-.09 DSI 0.51 ODSCC TSP AXIAL In Service via APC 2

4 94 H02-.06 DSI 0.97 ODSCC TSP AXIAL In Service via APC 2

4 94 H02+.29 SAI 0.23 ODSCC TSP AXIAL In Service via APC 2

4 94 H02+.32 SAI 0.24 ODSCC TSP AXIAL In Service via APC 2

5 1

H02-.06 DSI 0.56 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 26 of 88 2

5 5

H04+.00 DSI 0.59 ODSCC TSP AXIAL In Service via APC 2

5 6

H02+.00 DSI 0.75 ODSCC TSP AXIAL In Service via APC 2

5 27 H01-.03 DSI 0.39 ODSCC TSP AXIAL In Service via APC 2

5 28 C04-.09 DSI 0.35 ODSCC TSP AXIAL In Service via APC 2

5 59 H02+.00 DSI 0.53 ODSCC TSP AXIAL In Service via APC 2

5 60 H01+.00 DSI 0.68 ODSCC TSP AXIAL In Service via APC 2

5 60 H04-.03 DSI 0.43 ODSCC TSP AXIAL In Service via APC 2

5 65 H01+.06 DSI 0.5 ODSCC TSP AXIAL In Service via APC 2

5 65 H02+.00 DSI 0.76 ODSCC TSP AXIAL In Service via APC 2

5 65 H02+.18 SAI 0.12 ODSCC TSP AXIAL In Service via APC 2

5 66 H02-.09 DSI 0.48 ODSCC TSP AXIAL In Service via APC 2

5 91 H01-.03 DSI 1.04 ODSCC TSP AXIAL In Service via APC 2

5 91 H01+.23 SAI 0.26 ODSCC TSP AXIAL In Service via APC 2

5 92 H01+.06 DSI 0.93 ODSCC TSP AXIAL In Service via APC 2

5 93 H01+.00 DSI 0.93 ODSCC TSP AXIAL In Service via APC 2

5 94 C04+.00 DSI 0.57 ODSCC TSP AXIAL In Service via APC 2

5 94 H01-.09 DSI 0.63 ODSCC TSP AXIAL In Service via APC 2

6 1

H02-.03 DSI 0.85 ODSCC TSP AXIAL In Service via APC 2

6 3

H02+.00 DSI 0.64 ODSCC TSP AXIAL In Service via APC 2

6 4

H01+.00 DSI 0.36 ODSCC TSP AXIAL In Service via APC 2

6 13 H04+.00 DSI 0.34 ODSCC TSP AXIAL In Service via APC 2

6 16 H02+.00 DSI 0.47 ODSCC TSP AXIAL In Service via APC 2

6 24 H02+.06 DSI 0.32 ODSCC TSP AXIAL In Service via APC 2

6 38 H02-.09 DSI 0.72 ODSCC TSP AXIAL In Service via APC 2

6 39 H02-.03 DSI 0.93 ODSCC TSP AXIAL In Service via APC 2

6 40 H01+.03 DSI 0.75 ODSCC TSP AXIAL In Service via APC 2

6 43 H02-.14 DSI 1.48 ODSCC TSP AXIAL In Service via APC 2

6 43 H02+.01 SAI 0.21 ODSCC TSP AXIAL In Service via APC 2

6 48 H01-.12 DSI 0.73 ODSCC TSP AXIAL In Service via APC 2

6 55 C02+.00 DSI 0.25 ODSCC TSP AXIAL In Service via APC 2

6 57 H02-.09 DSI 0.55 ODSCC TSP AXIAL In Service via APC 2

6 68 H06+.00 DSI 0.37 ODSCC TSP AXIAL In Service via APC 2

6 70 H02-.06 DSI 0.37 ODSCC TSP AXIAL In Service via APC 2

6 84 H02+.00 DSI 0.87 ODSCC TSP AXIAL In Service via APC 2

6 90 H02-.03 DSI 0.4 ODSCC TSP AXIAL In Service via APC 2

6 90 H04+.00 DSI 0.45 ODSCC TSP AXIAL In Service via APC 2

6 94 H01+.00 DSI 0.66 ODSCC TSP AXIAL In Service via APC 2

7 1

H05-.03 DSI 0.5 ODSCC TSP AXIAL In Service via APC 2

7 2

H04-.03 DSI 0.86 ODSCC TSP AXIAL In Service via APC 2

7 4

H01+.03 DSI 0.7 ODSCC TSP AXIAL In Service via APC 2

7 4

H02+.06 DSI 0.92 ODSCC TSP AXIAL In Service via APC 2

7 7

H04+.03 DSI 0.72 ODSCC TSP AXIAL In Service via APC 2

7 9

H02-.06 DSI 0.43 ODSCC TSP AXIAL In Service via APC 2

7 9

H04-.06 DSI 0.61 ODSCC TSP AXIAL In Service via APC 2

7 10 H02+.00 DSI 0.52 ODSCC TSP AXIAL In Service via APC 2

7 10 H02+.34 SAI 0.12 ODSCC TSP AXIAL In Service via APC 2

7 12 H04-.03 DSI 0.48 ODSCC TSP AXIAL In Service via APC 2

7 13 H01-.09 DSI 0.53 ODSCC TSP AXIAL In Service via APC 2

7 13 H02-.03 DSI 0.57 ODSCC TSP AXIAL In Service via APC 2

7 17 H01+.06 DSI 0.53 ODSCC TSP AXIAL In Service via APC 2

7 17 H01+.00 SAI 0.21 ODSCC TSP AXIAL In Service via APC 2

7 17 H01+.24 SAI 0.1 ODSCC TSP AXIAL In Service via APC 2

7 20 H05+.14 DSI 1.59 ODSCC TSP AXIAL PLUGGED 2

7 20 H05+.24 SAI 0.17 ODSCC TSP AXIAL PLUGGED 2

7 21 H01-.03 DSI 0.48 ODSCC TSP AXIAL In Service via APC 2

7 21 H04+.00 DSI 0.37 ODSCC TSP AXIAL In Service via APC 2

7 21 H04+.05 SAI 0.11 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 27 of 88 2

7 27 H01+.00 DSI 0.61 ODSCC TSP AXIAL In Service via APC 2

7 27 H01+.20 SAI 0.32 ODSCC TSP AXIAL In Service via APC 2

7 32 H03+.00 DSI 0.82 ODSCC TSP AXIAL In Service via APC 2

7 32 H03+.10 SAI 0.21 ODSCC TSP AXIAL In Service via APC 2

7 38 H02+.03 DSI 0.23 ODSCC TSP AXIAL In Service via APC 2

7 42 H04+.00 DSI 0.12 ODSCC TSP AXIAL In Service via APC 2

7 43 H02-.03 DSI 0.67 ODSCC TSP AXIAL In Service via APC 2

7 44 H01+.00 DSI 0.94 ODSCC TSP AXIAL In Service via APC 2

7 44 H01+.16 SAI 0.12 ODSCC TSP AXIAL In Service via APC 2

7 57 H02+.00 DSI 1.07 ODSCC TSP AXIAL In Service via APC 2

7 58 H01-.03 DSI 0.78 ODSCC TSP AXIAL In Service via APC 2

7 67 H02-.03 DSI 0.38 ODSCC TSP AXIAL In Service via APC 2

7 68 H01-.06 DSI 0.62 ODSCC TSP AXIAL In Service via APC 2

7 68 H02-.03 DSI 0.51 ODSCC TSP AXIAL In Service via APC 2

7 71 H02-.03 DSI 0.37 ODSCC TSP AXIAL In Service via APC 2

7 72 H01-.06 DSI 0.62 ODSCC TSP AXIAL In Service via APC 2

7 89 H02+.00 DSI 0.81 ODSCC TSP AXIAL In Service via APC 2

7 89 H02+.18 SAI 0.12 ODSCC TSP AXIAL In Service via APC 2

7 91 H01+.00 DSI 0.3 ODSCC TSP AXIAL In Service via APC 2

8 3

H01+.17 DSI 1.07 ODSCC TSP AXIAL In Service via APC 2

8 3

H01+.11 SAI 0.14 ODSCC TSP AXIAL In Service via APC 2

8 3

H01+.20 SAI 0.16 ODSCC TSP AXIAL In Service via APC 2

8 11 H02+.00 DSI 0.27 ODSCC TSP AXIAL In Service via APC 2

8 13 H02+.03 DSI 0.43 ODSCC TSP AXIAL In Service via APC 2

8 34 H03-.03 DSI 0.21 ODSCC TSP AXIAL In Service via APC 2

8 38 H02+.00 DSI 0.71 ODSCC TSP AXIAL In Service via APC 2

8 42 H02+.03 DSI 0.28 ODSCC TSP AXIAL In Service via APC 2

8 44 H01+.00 DSI 1.17 ODSCC TSP AXIAL In Service via APC 2

8 44 H01+.07 SAI 0.08 ODSCC TSP AXIAL In Service via APC 2

8 44 H01+.12 SAI 0.19 ODSCC TSP AXIAL In Service via APC 2

8 45 H02-.03 DSI 0.71 ODSCC TSP AXIAL In Service via APC 2

8 47 H02+.00 DSI 0.67 ODSCC TSP AXIAL In Service via APC 2

8 51 H01+.00 DSI 0.89 ODSCC TSP AXIAL In Service via APC 2

8 51 H02+.03 DSI 0.56 ODSCC TSP AXIAL In Service via APC 2

8 60 H01-.06 DSI 0.49 ODSCC TSP AXIAL In Service via APC 2

8 61 H02+.00 DSI 0.86 ODSCC TSP AXIAL In Service via APC 2

8 62 H07+.11 DSI 0.14 ODSCC TSP AXIAL In Service via APC 2

8 64 H02-.03 DSI 0.58 ODSCC TSP AXIAL In Service via APC 2

8 68 H02+.00 DSI 0.38 ODSCC TSP AXIAL In Service via APC 2

8 69 H01+.00 DSI 0.58 ODSCC TSP AXIAL In Service via APC 2

8 70 H03+.00 DSI 0.53 ODSCC TSP AXIAL In Service via APC 2

8 71 H01+.00 DSI 0.62 ODSCC TSP AXIAL In Service via APC 2

8 90 H01+.03 DSI 0.55 ODSCC TSP AXIAL In Service via APC 2

8 90 H02-.06 DSI 0.37 ODSCC TSP AXIAL In Service via APC 2

8 91 H01-.03 DSI 0.57 ODSCC TSP AXIAL In Service via APC 2

9 14 H02+.03 DSI 0.42 ODSCC TSP AXIAL In Service via APC 2

9 22 H02-.14 DSI 0.58 ODSCC TSP AXIAL In Service via APC 2

9 23 H02-.06 DSI 0.41 ODSCC TSP AXIAL In Service via APC 2

9 29 H04-.06 DSI 0.31 ODSCC TSP AXIAL In Service via APC 2

9 32 H01-.06 DSI 0.6 ODSCC TSP AXIAL In Service via APC 2

9 33 H01-.03 DSI 1.26 ODSCC TSP AXIAL In Service via APC 2

9 33 H01+.08 SAI 0.17 ODSCC TSP AXIAL In Service via APC 2

9 33 H01+.19 SAI 0.11 ODSCC TSP AXIAL In Service via APC 2

9 36 H02+.00 DSI 0.48 ODSCC TSP AXIAL In Service via APC 2

9 40 H02+.00 DSI 0.58 ODSCC TSP AXIAL In Service via APC 2

9 41 H02-.03 DSI 0.3 ODSCC TSP AXIAL In Service via APC 2

9 41 H02-.19 SAI 0.14 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 28 of 88 2

9 41 H02+.03 SAI 0.13 ODSCC TSP AXIAL In Service via APC 2

9 41 H05+.00 DSI 0.67 ODSCC TSP AXIAL In Service via APC 2

9 48 H02-.03 DSI 0.67 ODSCC TSP AXIAL In Service via APC 2

9 50 H04-.06 DSI 0.31 ODSCC TSP AXIAL In Service via APC 2

9 57 H02-.03 DSI 0.72 ODSCC TSP AXIAL In Service via APC 2

9 69 H02+.06 DSI 0.4 ODSCC TSP AXIAL In Service via APC 2

9 72 H01+.03 DSI 0.3 ODSCC TSP AXIAL In Service via APC 2

9 72 H02-.11 DSI 0.59 ODSCC TSP AXIAL In Service via APC 2

9 91 H01+.03 DSI 1.34 ODSCC TSP AXIAL In Service via APC 2

9 91 H01+.15 SAI 0.13 ODSCC TSP AXIAL In Service via APC 2

10 4

H02+.00 DSI 0.77 ODSCC TSP AXIAL In Service via APC 2

10 18 C05+.14 DSI 1.3 ODSCC TSP AXIAL In Service via APC 2

10 31 H01+.06 DSI 0.78 ODSCC TSP AXIAL In Service via APC 2

10 31 H02-.14 DSI 1.23 ODSCC TSP AXIAL In Service via APC 2

10 31 H02+.01 SAI 0.11 ODSCC TSP AXIAL In Service via APC 2

10 31 H02+.12 SAI 0.1 ODSCC TSP AXIAL In Service via APC 2

10 31 H02+.15 SAI 0.16 ODSCC TSP AXIAL In Service via APC 2

10 31 H04+.09 DSI 0.48 ODSCC TSP AXIAL In Service via APC 2

10 32 H05+.09 DSI 0.5 ODSCC TSP AXIAL In Service via APC 2

10 89 H02+.03 DSI 0.66 ODSCC TSP AXIAL In Service via APC 2

10 89 H02+.22 SAI 0.18 ODSCC TSP AXIAL In Service via APC 2

11 21 H01+.09 DSI 0.94 ODSCC TSP AXIAL In Service via APC 2

11 25 H01+.09 DSI 0.42 ODSCC TSP AXIAL In Service via APC 2

11 25 H02+.12 DSI 0.39 ODSCC TSP AXIAL In Service via APC 2

11 57 H01-.03 DSI 0.69 ODSCC TSP AXIAL In Service via APC 2

11 63 H02-.03 DSI 0.32 ODSCC TSP AXIAL In Service via APC 2

11 65 H02+.09 DSI 0.7 ODSCC TSP AXIAL In Service via APC 2

11 67 H02-.06 DSI 1.68 ODSCC TSP AXIAL In Service via APC 2

11 67 H02+.16 SAI 0.08 ODSCC TSP AXIAL In Service via APC 2

11 75 H02-.03 DSI 0.84 ODSCC TSP AXIAL In Service via APC 2

11 88 H02+.00 DSI 0.57 ODSCC TSP AXIAL In Service via APC 2

11 91 C01-.12 DSI 0.2 ODSCC TSP AXIAL In Service via APC 2

12 6

H02+.09 DSI 1.17 ODSCC TSP AXIAL In Service via APC 2

12 44 H02+.08 DSI 0.82 ODSCC TSP AXIAL In Service via APC 2

12 51 C03+.03 DSI 0.32 ODSCC TSP AXIAL In Service via APC 2

12 59 H01-.03 DSI 0.43 ODSCC TSP AXIAL In Service via APC 2

12 59 H02-.06 DSI 0.55 ODSCC TSP AXIAL In Service via APC 2

12 60 C02+.06 DSI 0.29 ODSCC TSP AXIAL In Service via APC 2

12 85 H02-.09 DSI 0.57 ODSCC TSP AXIAL In Service via APC 2

12 90 H02+.12 DSI 0.67 ODSCC TSP AXIAL In Service via APC 2

13 21 H02+.06 DSI 0.37 ODSCC TSP AXIAL In Service via APC 2

13 68 H01+.00 DSI 0.91 ODSCC TSP AXIAL In Service via APC 2

13 68 H02-.03 DSI 0.53 ODSCC TSP AXIAL In Service via APC 2

13 89 H01+.00 DSI 0.68 ODSCC TSP AXIAL In Service via APC 2

14 11 H02+.03 DSI 0.47 ODSCC TSP AXIAL In Service via APC 2

14 18 H02+.06 DSI 0.34 ODSCC TSP AXIAL In Service via APC 2

14 84 H01+.00 DSI 0.78 ODSCC TSP AXIAL In Service via APC 2

14 86 H01+.03 DSI 0.99 ODSCC TSP AXIAL In Service via APC 2

14 86 H01+.19 SAI 0.47 ODSCC TSP AXIAL In Service via APC 2

14 90 H01+.06 DSI 0.46 ODSCC TSP AXIAL In Service via APC 2

14 90 H01+.12 SAI 0.17 ODSCC TSP AXIAL In Service via APC 2

14 90 H01+.16 SAI 0.19 ODSCC TSP AXIAL In Service via APC 2

15 5

H01-.03 DSI 1.08 ODSCC TSP AXIAL In Service via APC 2

15 5

H01+.23 SAI 0.21 ODSCC TSP AXIAL In Service via APC 2

15 5

H01+.24 SAI 0.26 ODSCC TSP AXIAL In Service via APC 2

15 5

H01+.28 SAI 0.23 ODSCC TSP AXIAL In Service via APC 2

15 32 H04+.06 DSI 0.56 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 29 of 88 2

15 36 H01+.06 DSI 0.76 ODSCC TSP AXIAL In Service via APC 2

15 40 H02-.14 DSI 1.16 ODSCC TSP AXIAL In Service via APC 2

15 40 H02+.09 SAI 0.17 ODSCC TSP AXIAL In Service via APC 2

15 40 H02+.32 SAI 0.28 ODSCC TSP AXIAL In Service via APC 2

15 49 H01-.06 DSI 0.61 ODSCC TSP AXIAL In Service via APC 2

15 49 H02-.06 DSI 0.86 ODSCC TSP AXIAL In Service via APC 2

15 87 H01-.03 DSI 0.76 ODSCC TSP AXIAL In Service via APC 2

15 87 H02-.06 DSI 0.5 ODSCC TSP AXIAL In Service via APC 2

15 87 H02+.20 SAI 0.26 ODSCC TSP AXIAL In Service via APC 2

15 89 H01+.00 DSI 1.38 ODSCC TSP AXIAL In Service via APC 2

15 89 H01+.06 SAI 0.13 ODSCC TSP AXIAL In Service via APC 2

15 89 H01+.09 SAI 0.13 ODSCC TSP AXIAL In Service via APC 2

15 89 H01+.21 SAI 0.19 ODSCC TSP AXIAL In Service via APC 2

15 89 H01+.23 SAI 0.22 ODSCC TSP AXIAL In Service via APC 2

15 89 H01+.25 SAI 0.17 ODSCC TSP AXIAL In Service via APC 2

15 89 H01+.36 SAI 0.35 ODSCC TSP AXIAL In Service via APC 2

16 11 H02+.03 DSI 0.74 ODSCC TSP AXIAL In Service via APC 2

16 33 H03+.06 DSI 0.4 ODSCC TSP AXIAL In Service via APC 2

16 41 C02+.00 DSI 0.29 ODSCC TSP AXIAL In Service via APC 2

16 48 H05-.21 DSI 0.4 ODSCC TSP AXIAL In Service via APC 2

16 48 H05-.06 SAI 0.11 ODSCC TSP AXIAL In Service via APC 2

16 60 H01-.03 DSI 0.78 ODSCC TSP AXIAL In Service via APC 2

16 80 H03+.03 DSI 0.34 ODSCC TSP AXIAL In Service via APC 2

17 41 H01+.08 DSI 0.62 ODSCC TSP AXIAL In Service via APC 2

17 49 H01-.06 DSI 0.4 ODSCC TSP AXIAL In Service via APC 2

17 77 C04+.18 DSI 0.37 ODSCC TSP AXIAL In Service via APC 2

17 86 H03+.03 DSI 0.44 ODSCC TSP AXIAL In Service via APC 2

18 7

H02+.18 DSI 1.61 ODSCC TSP AXIAL In Service via APC 2

18 7

H02+.16 SAI 0.09 ODSCC TSP AXIAL In Service via APC 2

18 7

H02+.28 SAI 0.13 ODSCC TSP AXIAL In Service via APC 2

18 11 H01+.31 DSI 1.5 ODSCC TSP AXIAL In Service via APC 2

18 11 H01+.16 SAI 0.14 ODSCC TSP AXIAL In Service via APC 2

18 11 H01+.35 SAI 0.18 ODSCC TSP AXIAL In Service via APC 2

18 14 H02+.12 DSI 0.52 ODSCC TSP AXIAL In Service via APC 2

18 22 H01-.06 DSI 0.6 ODSCC TSP AXIAL In Service via APC 2

18 56 H02-.06 DSI 0.76 ODSCC TSP AXIAL In Service via APC 2

19 15 H02+.03 DSI 0.41 ODSCC TSP AXIAL In Service via APC 2

19 22 H01+.06 DSI 0.44 ODSCC TSP AXIAL In Service via APC 2

19 22 H02+.03 DSI 0.68 ODSCC TSP AXIAL In Service via APC 2

19 61 H01+.00 DSI 0.57 ODSCC TSP AXIAL In Service via APC 2

19 63 H02+.00 DSI 0.56 ODSCC TSP AXIAL In Service via APC 2

19 68 H02-.09 DSI 0.18 ODSCC TSP AXIAL In Service via APC 2

19 69 H01-.06 DSI 0.61 ODSCC TSP AXIAL In Service via APC 2

19 70 H02+.00 DSI 0.2 ODSCC TSP AXIAL In Service via APC 2

20 10 H03-.03 DSI 0.3 ODSCC TSP AXIAL In Service via APC 2

20 22 H03+.06 DSI 0.32 ODSCC TSP AXIAL In Service via APC 2

20 33 H04+.09 DSI 0.31 ODSCC TSP AXIAL In Service via APC 2

20 43 H05+.03 DSI 0.82 ODSCC TSP AXIAL In Service via APC 2

20 44 H02+.09 DSI 0.44 ODSCC TSP AXIAL In Service via APC 2

20 49 H01-.06 DSI 0.72 ODSCC TSP AXIAL In Service via APC 2

20 49 H02+.00 DSI 0.89 ODSCC TSP AXIAL In Service via APC 2

20 52 H01+.03 DSI 1.09 ODSCC TSP AXIAL In Service via APC 2

20 52 H01+.31 SAI 0.39 ODSCC TSP AXIAL In Service via APC 2

20 56 H02-.03 DSI 0.84 ODSCC TSP AXIAL In Service via APC 2

20 57 H01-.03 DSI 0.59 ODSCC TSP AXIAL In Service via APC 2

20 58 H01-.09 DSI 0.74 ODSCC TSP AXIAL In Service via APC 2

20 62 H01-.03 DSI 0.67 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 30 of 88 2

20 64 H05+.03 DSI 0.5 ODSCC TSP AXIAL In Service via APC 2

20 65 H01-.09 DSI 0.5 ODSCC TSP AXIAL In Service via APC 2

20 89 H02+.00 DSI 0.39 ODSCC TSP AXIAL In Service via APC 2

21 9

H02+.03 DSI 1.04 ODSCC TSP AXIAL In Service via APC 2

21 20 H02+.06 DSI 0.46 ODSCC TSP AXIAL In Service via APC 2

21 20 H02+.23 SAI 0.14 ODSCC TSP AXIAL In Service via APC 2

21 20 H02+.31 SAI 0.19 ODSCC TSP AXIAL In Service via APC 2

21 61 H01+.06 DSI 0.62 ODSCC TSP AXIAL In Service via APC 2

21 64 H01-.12 DSI 0.4 ODSCC TSP AXIAL In Service via APC 2

21 69 H01-.03 DSI 0.48 ODSCC TSP AXIAL In Service via APC 2

21 69 H01+.13 SAI 0.3 ODSCC TSP AXIAL In Service via APC 2

21 69 H01+.15 SAI 0.12 ODSCC TSP AXIAL In Service via APC 2

21 87 H01+.03 DSI 0.42 ODSCC TSP AXIAL In Service via APC 2

22 30 H02+.09 DSI 0.68 ODSCC TSP AXIAL In Service via APC 2

22 34 H01+.06 DSI 0.52 ODSCC TSP AXIAL In Service via APC 2

22 36 H04+.00 DSI 0.57 ODSCC TSP AXIAL In Service via APC 2

22 37 H05+.06 DSI 0.44 ODSCC TSP AXIAL In Service via APC 2

22 58 H01+.18 DSI 1.4 ODSCC TSP AXIAL In Service via APC 2

22 58 H01+.24 SAI 0.16 ODSCC TSP AXIAL In Service via APC 2

22 58 H01+.37 SAI 0.36 ODSCC TSP AXIAL In Service via APC 2

22 68 H02-.03 DSI 0.33 ODSCC TSP AXIAL In Service via APC 2

22 69 H01-.03 DSI 0.66 ODSCC TSP AXIAL In Service via APC 2

22 73 H04-.03 DSI 0.78 ODSCC TSP AXIAL In Service via APC 2

23 17 H02+.06 DSI 0.66 ODSCC TSP AXIAL In Service via APC 2

23 22 H02+.12 DSI 0.92 ODSCC TSP AXIAL In Service via APC 2

23 44 H01+.17 DSI 1.32 ODSCC TSP AXIAL In Service via APC 2

23 44 H01+.09 SAI 0.18 ODSCC TSP AXIAL In Service via APC 2

23 44 H05+.00 DSI 0.66 ODSCC TSP AXIAL In Service via APC 2

23 49 H01+.03 DSI 1.44 ODSCC TSP AXIAL In Service via APC 2

23 49 H01+.28 SAI 0.29 ODSCC TSP AXIAL In Service via APC 2

23 49 H01+.35 SAI 0.46 ODSCC TSP AXIAL In Service via APC 2

23 55 H01+.00 DSI 0.47 ODSCC TSP AXIAL In Service via APC 2

23 70 H03-.09 DSI 0.56 ODSCC TSP AXIAL In Service via APC 2

23 72 H02-.03 DSI 0.19 ODSCC TSP AXIAL In Service via APC 2

23 73 H02-.06 DSI 1.43 ODSCC TSP AXIAL In Service via APC 2

23 73 H02+.11 SAI 0.17 ODSCC TSP AXIAL In Service via APC 2

23 73 H02+.26 SAI 0.11 ODSCC TSP AXIAL In Service via APC 2

23 74 H03-.06 DSI 0.32 ODSCC TSP AXIAL In Service via APC 2

23 85 H01-.09 DSI 0.34 ODSCC TSP AXIAL In Service via APC 2

23 85 H02+.00 DSI 0.34 ODSCC TSP AXIAL In Service via APC 2

23 86 H02+.12 DSI 0.98 ODSCC TSP AXIAL In Service via APC 2

24 37 H02+.09 DSI 0.77 ODSCC TSP AXIAL In Service via APC 2

24 37 H04+.23 DSI 1.14 ODSCC TSP AXIAL In Service via APC 2

24 37 H04+.35 SAI 0.24 ODSCC TSP AXIAL In Service via APC 2

24 38 H02-.14 DSI 1.5 ODSCC TSP AXIAL In Service via APC 2

24 38 H02+.34 SAI 0.21 ODSCC TSP AXIAL In Service via APC 2

24 43 H02+.23 DSI 1.03 ODSCC TSP AXIAL In Service via APC 2

24 43 H02+.32 SAI 0.23 ODSCC TSP AXIAL In Service via APC 2

24 43 H02+.35 SAI 0.26 ODSCC TSP AXIAL In Service via APC 2

24 50 H01-.09 DSI 0.69 ODSCC TSP AXIAL In Service via APC 2

24 60 H02-.03 DSI 0.88 ODSCC TSP AXIAL In Service via APC 2

24 60 H02+.21 SAI 0.14 ODSCC TSP AXIAL In Service via APC 2

24 87 H01-.03 DSI 0.98 ODSCC TSP AXIAL In Service via APC 2

24 87 H04+.00 DSI 0.36 ODSCC TSP AXIAL In Service via APC 2

25 9

H07-.06 DSI 0.57 ODSCC TSP AXIAL In Service via APC 2

25 22 H02+.09 DSI 1.09 ODSCC TSP AXIAL In Service via APC 2

25 22 H02+.00 SAI 0.1 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 31 of 88 2

25 22 H02+.14 SAI 0.16 ODSCC TSP AXIAL In Service via APC 2

25 22 H02+.26 SAI 0.14 ODSCC TSP AXIAL In Service via APC 2

25 43 H02+.00 DSI 0.5 ODSCC TSP AXIAL In Service via APC 2

25 56 H03+.13 DSI 1

ODSCC TSP AXIAL In Service via APC 2

25 56 H03+.30 SAI 0.43 ODSCC TSP AXIAL In Service via APC 2

25 66 H03+.00 DSI 0.74 ODSCC TSP AXIAL In Service via APC 2

25 68 H03-.09 DSI 0.42 ODSCC TSP AXIAL In Service via APC 2

25 72 H02+.00 DSI 0.63 ODSCC TSP AXIAL In Service via APC 2

25 72 H04+.06 DSI 0.54 ODSCC TSP AXIAL In Service via APC 2

26 11 C04-.06 DSI 0.31 ODSCC TSP AXIAL In Service via APC 2

26 17 H02+.09 DSI 0.74 ODSCC TSP AXIAL In Service via APC 2

26 17 H02+.09 SAI 0.09 ODSCC TSP AXIAL In Service via APC 2

26 18 H01+.29 DSI 0.99 ODSCC TSP AXIAL In Service via APC 2

26 59 H01-.03 DSI 1.1 ODSCC TSP AXIAL In Service via APC 2

26 59 H01+.08 SAI 0.14 ODSCC TSP AXIAL In Service via APC 2

26 59 H01+.29 SAI 0.41 ODSCC TSP AXIAL In Service via APC 2

26 59 H01+.32 SAI 0.49 ODSCC TSP AXIAL In Service via APC 2

26 59 H02+.00 DSI 0.68 ODSCC TSP AXIAL In Service via APC 2

26 59 H03-.03 DSI 0.46 ODSCC TSP AXIAL In Service via APC 2

27 53 H02+.00 DSI 0.95 ODSCC TSP AXIAL In Service via APC 2

27 68 H01+.00 DSI 0.86 ODSCC TSP AXIAL In Service via APC 2

27 68 H02+.00 DSI 0.74 ODSCC TSP AXIAL In Service via APC 2

27 84 H01+.00 DSI 0.96 ODSCC TSP AXIAL In Service via APC 2

27 84 H02-.03 DSI 0.9 ODSCC TSP AXIAL In Service via APC 2

28 12 H02+.09 DSI 0.64 ODSCC TSP AXIAL In Service via APC 2

28 17 H02+.06 DSI 0.98 ODSCC TSP AXIAL In Service via APC 2

28 60 H02-.03 DSI 0.66 ODSCC TSP AXIAL In Service via APC 2

28 60 H02+.33 SAI 0.23 ODSCC TSP AXIAL In Service via APC 2

28 66 H03+.00 DSI 0.56 ODSCC TSP AXIAL In Service via APC 2

28 69 H02-.03 DSI 0.54 ODSCC TSP AXIAL In Service via APC 2

28 73 H03-.06 DSI 0.89 ODSCC TSP AXIAL In Service via APC 2

28 79 H02+.00 DSI 0.83 ODSCC TSP AXIAL In Service via APC 2

29 16 H01+.26 DSI 1.26 ODSCC TSP AXIAL In Service via APC 2

29 16 H01+.20 SAI 0.1 ODSCC TSP AXIAL In Service via APC 2

29 16 H02+.12 DSI 0.8 ODSCC TSP AXIAL In Service via APC 2

29 17 H02+.03 DSI 0.99 ODSCC TSP AXIAL In Service via APC 2

29 20 H02+.09 DSI 0.85 ODSCC TSP AXIAL In Service via APC 2

29 21 H02+.06 DSI 0.89 ODSCC TSP AXIAL In Service via APC 2

29 45 H02+.06 DSI 0.21 ODSCC TSP AXIAL In Service via APC 2

29 61 H02+.00 DSI 0.65 ODSCC TSP AXIAL In Service via APC 2

29 61 H02+.36 SAI 0.18 ODSCC TSP AXIAL In Service via APC 2

29 61 H03+.06 DSI 0.45 ODSCC TSP AXIAL In Service via APC 2

29 67 H01+.03 DSI 0.59 ODSCC TSP AXIAL In Service via APC 2

29 79 H01+.03 DSI 0.28 ODSCC TSP AXIAL In Service via APC 2

29 79 H02-.06 DSI 0.34 ODSCC TSP AXIAL In Service via APC 2

30 16 H02+.09 DSI 0.89 ODSCC TSP AXIAL In Service via APC 2

30 17 H02+.09 DSI 0.45 ODSCC TSP AXIAL In Service via APC 2

30 19 H04+.00 DSI 0.74 ODSCC TSP AXIAL In Service via APC 2

30 20 H01+.14 DSI 1.05 ODSCC TSP AXIAL In Service via APC 2

30 20 H01+.23 SAI 0.13 ODSCC TSP AXIAL In Service via APC 2

30 20 H01+.24 SAI 0.28 ODSCC TSP AXIAL In Service via APC 2

30 21 H02+.06 DSI 0.84 ODSCC TSP AXIAL In Service via APC 2

30 22 H02+.09 DSI 1.18 ODSCC TSP AXIAL In Service via APC 2

30 46 C02+.06 DSI 0.2 ODSCC TSP AXIAL In Service via APC 2

30 54 H01+.12 DSI 1.39 ODSCC TSP AXIAL In Service via APC 2

30 54 H01+.22 SAI 0.27 ODSCC TSP AXIAL In Service via APC 2

30 54 H01+.32 SAI 0.47 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 32 of 88 2

30 55 H01+.15 DSI 1.5 ODSCC TSP AXIAL In Service via APC 2

30 55 H01+.35 SAI 0.43 ODSCC TSP AXIAL In Service via APC 2

30 55 H05+.00 DSI 0.41 ODSCC TSP AXIAL In Service via APC 2

30 68 H02-.03 DSI 1.47 ODSCC TSP AXIAL In Service via APC 2

30 68 H02+.06 SAI 0.19 ODSCC TSP AXIAL In Service via APC 2

30 68 H02+.30 SAI 0.15 ODSCC TSP AXIAL In Service via APC 2

30 68 H02+.36 SAI 0.19 ODSCC TSP AXIAL In Service via APC 2

30 70 H01-.03 DSI 0.36 ODSCC TSP AXIAL In Service via APC 2

30 74 H02-.03 DSI 1.52 ODSCC TSP AXIAL In Service via APC 2

30 74 H02+.21 SAI 0.24 ODSCC TSP AXIAL In Service via APC 2

30 74 H02+.26 SAI 0.13 ODSCC TSP AXIAL In Service via APC 2

30 74 H02+.29 SAI 0.13 ODSCC TSP AXIAL In Service via APC 2

30 76 H02-.03 DSI 1.12 ODSCC TSP AXIAL In Service via APC 2

30 77 H02+.00 DSI 0.63 ODSCC TSP AXIAL In Service via APC 2

30 77 H03+.00 DSI 0.74 ODSCC TSP AXIAL In Service via APC 2

30 79 H02-.03 DSI 0.89 ODSCC TSP AXIAL In Service via APC 2

30 81 H01+.00 DSI 1.2 ODSCC TSP AXIAL In Service via APC 2

30 81 H01+.03 SAI 0.31 ODSCC TSP AXIAL In Service via APC 2

30 81 H01+.22 SAI 0.28 ODSCC TSP AXIAL In Service via APC 2

30 81 H04-.03 DSI 0.93 ODSCC TSP AXIAL In Service via APC 2

30 82 H02+.03 DSI 0.53 ODSCC TSP AXIAL In Service via APC 2

30 83 H01-.09 DSI 0.81 ODSCC TSP AXIAL In Service via APC 2

30 83 H02-.03 DSI 0.59 ODSCC TSP AXIAL In Service via APC 2

31 25 H02+.06 DSI 0.47 ODSCC TSP AXIAL In Service via APC 2

31 38 H04+.00 DSI 0.41 ODSCC TSP AXIAL In Service via APC 2

31 39 H02+.06 DSI 0.34 ODSCC TSP AXIAL In Service via APC 2

31 47 H02-.03 DSI 0.61 ODSCC TSP AXIAL In Service via APC 2

31 48 H01-.06 DSI 0.41 ODSCC TSP AXIAL In Service via APC 2

31 66 H02+.00 DSI 0.58 ODSCC TSP AXIAL In Service via APC 2

31 67 H02+.03 DSI 0.61 ODSCC TSP AXIAL In Service via APC 2

31 67 H03+.06 DSI 0.45 ODSCC TSP AXIAL In Service via APC 2

31 70 H01+.00 DSI 1.29 ODSCC TSP AXIAL In Service via APC 2

31 70 H01+.19 SAI 0.23 ODSCC TSP AXIAL In Service via APC 2

31 70 H01+.36 SAI 0.36 ODSCC TSP AXIAL In Service via APC 2

31 70 H02-.12 DSI 0.78 ODSCC TSP AXIAL In Service via APC 2

31 74 H01-.03 DSI 0.34 ODSCC TSP AXIAL In Service via APC 2

31 74 H02-.03 DSI 0.7 ODSCC TSP AXIAL In Service via APC 2

32 17 H05+.09 DSI 1.17 ODSCC TSP AXIAL In Service via APC 2

32 19 C01-.23 DSI 0.35 ODSCC TSP AXIAL In Service via APC 2

32 20 H01+.14 DSI 1.81 ODSCC TSP AXIAL In Service via APC 2

32 20 H01+.08 SAI 0.25 ODSCC TSP AXIAL In Service via APC 2

32 20 H01+.25 SAI 0.26 ODSCC TSP AXIAL In Service via APC 2

32 20 H01+.31 SAI 0.26 ODSCC TSP AXIAL In Service via APC 2

32 20 H02+.00 DSI 1.35 ODSCC TSP AXIAL In Service via APC 2

32 20 H02+.09 SAI 0.12 ODSCC TSP AXIAL In Service via APC 2

32 20 H02+.31 SAI 0.15 ODSCC TSP AXIAL In Service via APC 2

32 20 H02+.32 SAI 0.15 ODSCC TSP AXIAL In Service via APC 2

32 20 H02+.34 SAI 0.17 ODSCC TSP AXIAL In Service via APC 2

32 21 H02+.09 DSI 0.59 ODSCC TSP AXIAL In Service via APC 2

32 21 H02+.23 SAI 0.1 ODSCC TSP AXIAL In Service via APC 2

32 23 H02+.09 DSI 0.69 ODSCC TSP AXIAL In Service via APC 2

32 26 H01+.06 DSI 0.55 ODSCC TSP AXIAL In Service via APC 2

32 32 H01+.00 DSI 0.46 ODSCC TSP AXIAL In Service via APC 2

32 32 H01+.11 SAI 0.17 ODSCC TSP AXIAL In Service via APC 2

32 32 H01+.31 SAI 0.16 ODSCC TSP AXIAL In Service via APC 2

32 61 H02-.06 DSI 0.7 ODSCC TSP AXIAL In Service via APC 2

32 63 H01-.06 DSI 0.3 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 33 of 88 2

33 31 H02-.09 DSI 1.71 ODSCC TSP AXIAL In Service via APC 2

33 31 H02+.13 SAI 0.15 ODSCC TSP AXIAL In Service via APC 2

33 31 H02+.14 SAI 0.09 ODSCC TSP AXIAL In Service via APC 2

33 31 H02+.15 SAI 0.17 ODSCC TSP AXIAL In Service via APC 2

33 50 H07+.09 DSI 0.2 ODSCC TSP AXIAL In Service via APC 2

34 72 H01-.03 DSI 0.23 ODSCC TSP AXIAL In Service via APC 2

34 73 H01+.03 DSI 0.36 ODSCC TSP AXIAL In Service via APC 2

35 42 H02+.00 DSI 0.24 ODSCC TSP AXIAL In Service via APC 2

35 44 H02+.00 DSI 0.65 ODSCC TSP AXIAL In Service via APC 2

35 45 H02+.06 DSI 0.42 ODSCC TSP AXIAL In Service via APC 2

35 58 H04+.06 DSI 0.59 ODSCC TSP AXIAL In Service via APC 2

35 59 H02-.03 DSI 0.42 ODSCC TSP AXIAL In Service via APC 2

35 61 H03+.00 DSI 0.54 ODSCC TSP AXIAL In Service via APC 2

35 72 H03-.03 DSI 0.39 ODSCC TSP AXIAL In Service via APC 2

35 75 H01+.06 DSI 0.18 ODSCC TSP AXIAL In Service via APC 2

36 33 H02+.06 DSI 0.68 ODSCC TSP AXIAL In Service via APC 2

36 42 H01+.12 DSI 0.3 ODSCC TSP AXIAL In Service via APC 2

36 42 H02+.15 DSI 0.7 ODSCC TSP AXIAL In Service via APC 2

36 63 H02-.06 DSI 0.37 ODSCC TSP AXIAL In Service via APC 2

36 64 H01+.06 DSI 0.93 ODSCC TSP AXIAL In Service via APC 2

36 71 H01+.06 DSI 1.28 ODSCC TSP AXIAL In Service via APC 2

36 71 H01+.23 SAI 0.22 ODSCC TSP AXIAL In Service via APC 2

36 71 H01+.26 SAI 0.2 ODSCC TSP AXIAL In Service via APC 2

36 71 H01+.27 SAI 0.11 ODSCC TSP AXIAL In Service via APC 2

36 71 H02+.00 DSI 0.8 ODSCC TSP AXIAL In Service via APC 2

36 71 H02+.28 SAI 0.12 ODSCC TSP AXIAL In Service via APC 2

36 74 H02-.03 DSI 0.59 ODSCC TSP AXIAL In Service via APC 2

36 75 H02+.00 DSI 0.89 ODSCC TSP AXIAL In Service via APC 2

37 20 H01+.12 DSI 1.11 ODSCC TSP AXIAL In Service via APC 2

37 20 H01+.06 SAI 0.09 ODSCC TSP AXIAL In Service via APC 2

37 20 H01+.15 SAI 0.19 ODSCC TSP AXIAL In Service via APC 2

37 20 H01+.29 SAI 0.22 ODSCC TSP AXIAL In Service via APC 2

37 23 C01-.29 DSI 0.52 ODSCC TSP AXIAL In Service via APC 2

37 26 H02+.11 DSI 0.44 ODSCC TSP AXIAL In Service via APC 2

37 55 H02+.00 DSI 0.78 ODSCC TSP AXIAL In Service via APC 2

37 66 H01-.09 DSI 0.31 ODSCC TSP AXIAL In Service via APC 2

38 25 H02+.03 DSI 0.44 ODSCC TSP AXIAL In Service via APC 2

38 26 H01+.11 DSI 0.71 ODSCC TSP AXIAL In Service via APC 2

38 28 H02+.06 DSI 0.35 ODSCC TSP AXIAL In Service via APC 2

38 32 H02+.14 DSI 0.69 ODSCC TSP AXIAL In Service via APC 2

38 33 H02+.23 DSI 1.11 ODSCC TSP AXIAL In Service via APC 2

38 33 H03+.12 DSI 0.5 ODSCC TSP AXIAL In Service via APC 2

38 33 H04+.06 DSI 0.64 ODSCC TSP AXIAL In Service via APC 2

38 45 H02-.13 DSI 1.41 ODSCC TSP AXIAL In Service via APC 2

38 45 H02+.01 SAI 0.15 ODSCC TSP AXIAL In Service via APC 2

38 45 H02+.02 SAI 0.3 ODSCC TSP AXIAL In Service via APC 2

38 45 H02+.22 SAI 0.15 ODSCC TSP AXIAL In Service via APC 2

38 45 H03+.05 DSI 0.79 ODSCC TSP AXIAL In Service via APC 2

38 49 H02+.06 DSI 0.83 ODSCC TSP AXIAL In Service via APC 2

38 53 H02+.00 DSI 0.39 ODSCC TSP AXIAL In Service via APC 2

38 59 H02+.03 DSI 0.44 ODSCC TSP AXIAL In Service via APC 2

38 66 H01-.03 DSI 0.39 ODSCC TSP AXIAL In Service via APC 2

38 74 H04-.03 DSI 0.56 ODSCC TSP AXIAL In Service via APC 2

39 25 H01+.06 DSI 0.39 ODSCC TSP AXIAL In Service via APC 2

39 25 H02+.03 DSI 0.66 ODSCC TSP AXIAL In Service via APC 2

39 31 H02+.09 DSI 0.49 ODSCC TSP AXIAL In Service via APC 2

39 37 H02+.06 DSI 0.55 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 34 of 88 2

39 38 H02+.11 DSI 1.1 ODSCC TSP AXIAL In Service via APC 2

39 38 H02+.31 SAI 0.11 ODSCC TSP AXIAL In Service via APC 2

39 40 H02+.06 DSI 0.25 ODSCC TSP AXIAL In Service via APC 2

39 55 H02-.03 DSI 0.81 ODSCC TSP AXIAL In Service via APC 2

39 58 H04+.03 DSI 0.63 ODSCC TSP AXIAL In Service via APC 2

39 59 H02-.03 DSI 0.46 ODSCC TSP AXIAL In Service via APC 2

39 62 H02-.06 DSI 0.92 ODSCC TSP AXIAL In Service via APC 2

39 70 H02-.06 DSI 0.44 ODSCC TSP AXIAL In Service via APC 2

40 29 H02+.09 DSI 0.59 ODSCC TSP AXIAL In Service via APC 2

40 29 H02+.09 SAI 0.16 ODSCC TSP AXIAL In Service via APC 2

40 31 H02+.03 DSI 0.23 ODSCC TSP AXIAL In Service via APC 2

40 37 H02+.06 DSI 0.53 ODSCC TSP AXIAL In Service via APC 2

40 40 H03+.14 DSI 0.76 ODSCC TSP AXIAL In Service via APC 2

40 41 H03-.11 DSI 0.83 ODSCC TSP AXIAL In Service via APC 2

40 42 C02+.03 DSI 0.18 ODSCC TSP AXIAL In Service via APC 2

40 48 H05+.03 DSI 0.41 ODSCC TSP AXIAL In Service via APC 2

40 55 C02+.06 DSI 0.17 ODSCC TSP AXIAL In Service via APC 2

40 57 H02+.00 DSI 0.46 ODSCC TSP AXIAL In Service via APC 2

40 60 H02-.12 DSI 0.43 ODSCC TSP AXIAL In Service via APC 2

40 64 H01-.09 DSI 0.46 ODSCC TSP AXIAL In Service via APC 2

41 34 H02+.06 DSI 1.37 ODSCC TSP AXIAL In Service via APC 2

41 37 H02+.11 DSI 0.96 ODSCC TSP AXIAL In Service via APC 2

41 37 H04+.08 DSI 0.32 ODSCC TSP AXIAL In Service via APC 2

41 39 H02+.09 DSI 0.26 ODSCC TSP AXIAL In Service via APC 2

41 41 H04+.14 DSI 0.86 ODSCC TSP AXIAL In Service via APC 2

41 41 H04+.31 SAI 0.16 ODSCC TSP AXIAL In Service via APC 2

41 43 H02+.00 DSI 1.02 ODSCC TSP AXIAL In Service via APC 2

41 43 H02+.21 SAI 0.18 ODSCC TSP AXIAL In Service via APC 2

41 43 H03+.06 DSI 0.62 ODSCC TSP AXIAL In Service via APC 2

41 50 H01+.22 DSI 0.88 ODSCC TSP AXIAL In Service via APC 2

41 50 H02+.14 DSI 0.61 ODSCC TSP AXIAL In Service via APC 2

41 54 H01-.03 DSI 0.35 ODSCC TSP AXIAL In Service via APC 2

41 54 H02+.00 DSI 0.82 ODSCC TSP AXIAL In Service via APC 2

41 54 H03+.03 DSI 0.82 ODSCC TSP AXIAL In Service via APC 2

41 55 H03+.00 DSI 0.71 ODSCC TSP AXIAL In Service via APC 2

41 67 H01-.03 DSI 0.53 ODSCC TSP AXIAL In Service via APC 2

41 69 H01+.03 DSI 0.6 ODSCC TSP AXIAL In Service via APC 2

42 34 H02+.09 DSI 0.65 ODSCC TSP AXIAL In Service via APC 2

42 37 H05+.09 DSI 0.39 ODSCC TSP AXIAL In Service via APC 2

42 43 H03+.11 DSI 0.5 ODSCC TSP AXIAL In Service via APC 2

42 50 H02-.06 DSI 0.63 ODSCC TSP AXIAL In Service via APC 2

42 51 H02+.06 DSI 0.36 ODSCC TSP AXIAL In Service via APC 2

42 61 H01+.18 DSI 0.92 ODSCC TSP AXIAL In Service via APC 2

42 66 H06-.06 DSI 1.56 ODSCC TSP AXIAL In Service via APC 2

42 67 H06+.06 DSI 1.57 ODSCC TSP AXIAL In Service via APC 2

43 38 H02+.06 DSI 0.7 ODSCC TSP AXIAL In Service via APC 2

43 43 H02-.06 DSI 1

ODSCC TSP AXIAL In Service via APC 2

43 43 H02+.19 SAI 0.23 ODSCC TSP AXIAL In Service via APC 2

43 43 H03+.06 DSI 0.29 ODSCC TSP AXIAL In Service via APC 2

43 44 H03+.06 DSI 0.63 ODSCC TSP AXIAL In Service via APC 2

43 47 H02+.06 DSI 0.42 ODSCC TSP AXIAL In Service via APC 2

43 49 H02+.00 DSI 0.34 ODSCC TSP AXIAL In Service via APC 2

43 50 H01+.31 DSI 0.9 ODSCC TSP AXIAL In Service via APC 2

43 50 H02+.06 DSI 0.46 ODSCC TSP AXIAL In Service via APC 2

43 52 H01+.31 DSI 0.69 ODSCC TSP AXIAL In Service via APC 2

43 52 H01+.33 SAI 0.1 ODSCC TSP AXIAL In Service via APC 2

43 52 H01+.34 SAI 0.23 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 35 of 88 2

43 52 H02+.09 DSI 0.28 ODSCC TSP AXIAL In Service via APC 2

43 52 H02+.01 SAI 0.19 ODSCC TSP AXIAL In Service via APC 2

43 52 H03+.17 DSI 0.2 ODSCC TSP AXIAL In Service via APC 2

43 53 H04+.03 DSI 0.5 ODSCC TSP AXIAL In Service via APC 2

43 54 H04+.00 DSI 0.69 ODSCC TSP AXIAL In Service via APC 2

43 65 C01-.09 DSI 0.48 ODSCC TSP AXIAL In Service via APC 2

44 39 H02+.06 DSI 0.53 ODSCC TSP AXIAL In Service via APC 2

44 40 C01+.37 DSI 0.46 ODSCC TSP AXIAL In Service via APC 2

44 44 H02+.06 DSI 0.97 ODSCC TSP AXIAL In Service via APC 2

44 45 H02+.09 DSI 0.31 ODSCC TSP AXIAL In Service via APC 2

44 52 H02+.08 DSI 1.55 ODSCC TSP AXIAL In Service via APC 2

44 52 H02+.06 SAI 0.12 ODSCC TSP AXIAL In Service via APC 2

44 52 H02+.11 SAI 0.15 ODSCC TSP AXIAL In Service via APC 2

44 52 H02+.25 SAI 0.07 ODSCC TSP AXIAL In Service via APC 2

45 39 H03+.09 DSI 0.3 ODSCC TSP AXIAL In Service via APC 2

45 39 H04+.03 DSI 0.42 ODSCC TSP AXIAL In Service via APC 2

45 42 H02+.00 DSI 0.46 ODSCC TSP AXIAL In Service via APC 2

45 48 H02+.09 DSI 0.45 ODSCC TSP AXIAL In Service via APC 2

45 49 H03+.06 DSI 0.28 ODSCC TSP AXIAL In Service via APC 2

45 51 H02+.03 DSI 0.94 ODSCC TSP AXIAL In Service via APC 2

45 52 H01-.06 DSI 0.28 ODSCC TSP AXIAL In Service via APC 2

45 52 H02+.00 DSI 0.63 ODSCC TSP AXIAL In Service via APC 2

45 54 H02+.00 DSI 0.61 ODSCC TSP AXIAL In Service via APC 2

45 54 H02+.18 SAI 0.17 ODSCC TSP AXIAL In Service via APC 2

45 54 H02+.21 SAI 0.18 ODSCC TSP AXIAL In Service via APC 2

45 55 C01-.22 DSI 0.29 ODSCC TSP AXIAL In Service via APC 2

45 56 C01-.19 DSI 0.45 ODSCC TSP AXIAL In Service via APC 2

46 50 H02+.00 DSI 0.23 ODSCC TSP AXIAL In Service via APC 3

1 74 C01-.06 DSI 2.17 ODSCC TSP AXIAL In Service via APC 3

1 76 H03+.18 DSI 0.63 ODSCC TSP AXIAL In Service via APC 3

1 79 H02-.12 DSI 0.76 ODSCC TSP AXIAL In Service via APC 3

1 79 H03+.15 DSI 1.47 ODSCC TSP AXIAL In Service via APC 3

1 82 C01-.03 DSI 0.45 ODSCC TSP AXIAL In Service via APC 3

1 84 H03-.06 DSI 0.96 ODSCC TSP AXIAL In Service via APC 3

2 16 H01+.00 DSI 0.44 ODSCC TSP AXIAL In Service via APC 3

2 25 H02-.09 DSI 0.54 ODSCC TSP AXIAL In Service via APC 3

2 25 H03-.02 DSI 0.46 ODSCC TSP AXIAL In Service via APC 3

2 31 H01+.12 DSI 0.43 ODSCC TSP AXIAL In Service via APC 3

2 31 H03+.01 DSI 0.62 ODSCC TSP AXIAL In Service via APC 3

2 32 H01+.00 DSI 0.41 ODSCC TSP AXIAL In Service via APC 3

2 33 H01+.12 DSI 0.46 ODSCC TSP AXIAL In Service via APC 3

2 35 H01-.06 DSI 1

ODSCC TSP AXIAL In Service via APC 3

2 35 H01+.18 SAI 0.1 ODSCC TSP AXIAL In Service via APC 3

2 38 H02+.01 DSI 0.22 ODSCC TSP AXIAL In Service via APC 3

2 38 H04+.03 DSI 0.26 ODSCC TSP AXIAL In Service via APC 3

2 39 H02+.01 DSI 0.79 ODSCC TSP AXIAL In Service via APC 3

2 58 C01+.12 DSI 0.49 ODSCC TSP AXIAL In Service via APC 3

2 73 H02-.06 DSI 0.46 ODSCC TSP AXIAL In Service via APC 3

2 79 H01-.03 DSI 0.77 ODSCC TSP AXIAL In Service via APC 3

3 1

H01+.21 DSI 0.75 ODSCC TSP AXIAL In Service via APC 3

3 1

H02-.03 DSI 0.64 ODSCC TSP AXIAL In Service via APC 3

3 2

H01+.00 DSI 0.81 ODSCC TSP AXIAL In Service via APC 3

3 2

H03+.00 DSI 0.87 ODSCC TSP AXIAL In Service via APC 3

3 5

H01-.03 DSI 1.38 ODSCC TSP AXIAL In Service via APC 3

3 5

H01+.06 SAI 0.3 ODSCC TSP AXIAL In Service via APC 3

3 5

H05+.03 DSI 0.8 ODSCC TSP AXIAL In Service via APC 3

3 10 H01+.09 DSI 1.65 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 36 of 88 3

3 10 H01+.29 SAI 0.53 ODSCC TSP AXIAL In Service via APC 3

3 16 H03+.12 DSI 0.72 ODSCC TSP AXIAL In Service via APC 3

3 19 H01+.24 DSI 0.58 ODSCC TSP AXIAL In Service via APC 3

3 23 H01+.06 DSI 0.88 ODSCC TSP AXIAL In Service via APC 3

3 24 H02+.03 DSI 0.5 ODSCC TSP AXIAL In Service via APC 3

3 29 H01+.03 DSI 1.45 ODSCC TSP AXIAL In Service via APC 3

3 29 H01+.26 SAI 0.25 ODSCC TSP AXIAL In Service via APC 3

3 34 H01+.00 DSI 1.02 ODSCC TSP AXIAL In Service via APC 3

3 34 H05-.06 DSI 0.82 ODSCC TSP AXIAL In Service via APC 3

3 49 H02-.03 DSI 0.54 ODSCC TSP AXIAL In Service via APC 3

3 51 H02+.03 DSI 0.44 ODSCC TSP AXIAL In Service via APC 3

3 94 H02+.12 DSI 0.82 ODSCC TSP AXIAL In Service via APC 3

3 94 H04-.06 DSI 0.46 ODSCC TSP AXIAL In Service via APC 3

4 25 H02+.00 DSI 1.06 ODSCC TSP AXIAL In Service via APC 3

4 25 H02+.23 SAI 0.12 ODSCC TSP AXIAL In Service via APC 3

4 26 H01-.15 DSI 0.54 ODSCC TSP AXIAL In Service via APC 3

4 27 H01-.05 DSI 0.34 ODSCC TSP AXIAL In Service via APC 3

4 34 H01-.03 DSI 0.91 ODSCC TSP AXIAL In Service via APC 3

4 39 H01+.15 DSI 0.32 ODSCC TSP AXIAL In Service via APC 3

4 46 H01-.08 DSI 0.54 ODSCC TSP AXIAL In Service via APC 3

4 48 H01+.03 DSI 0.5 ODSCC TSP AXIAL In Service via APC 3

4 50 H01-.09 DSI 0.61 ODSCC TSP AXIAL In Service via APC 3

4 50 H05-.03 DSI 0.23 ODSCC TSP AXIAL In Service via APC 3

4 51 H01-.03 DSI 0.94 ODSCC TSP AXIAL In Service via APC 3

4 55 H01+.03 DSI 0.25 ODSCC TSP AXIAL In Service via APC 3

4 55 H02+.00 DSI 1.01 ODSCC TSP AXIAL In Service via APC 3

4 55 H02+.32 SAI 0.27 ODSCC TSP AXIAL In Service via APC 3

4 60 H02-.03 DSI 1.19 ODSCC TSP AXIAL In Service via APC 3

4 60 H02+.22 SAI 0.23 ODSCC TSP AXIAL In Service via APC 3

4 60 H02+.23 SAI 0.13 ODSCC TSP AXIAL In Service via APC 3

5 1

H01-.03 DSI 1.22 ODSCC TSP AXIAL In Service via APC 3

5 1

H01+.35 SAI 0.13 ODSCC TSP AXIAL In Service via APC 3

5 1

H02-.03 DSI 1.52 ODSCC TSP AXIAL In Service via APC 3

5 4

H01+.00 DSI 1.08 ODSCC TSP AXIAL In Service via APC 3

5 4

H01+.25 SAI 0.73 ODSCC TSP AXIAL In Service via APC 3

5 4

H01+.29 SAI 0.18 ODSCC TSP AXIAL In Service via APC 3

5 4

H02+.06 DSI 0.26 ODSCC TSP AXIAL In Service via APC 3

5 4

H03+.00 DSI 0.87 ODSCC TSP AXIAL In Service via APC 3

5 5

H02+.03 DSI 1.08 ODSCC TSP AXIAL In Service via APC 3

5 5

H03+.03 DSI 0.49 ODSCC TSP AXIAL In Service via APC 3

5 10 H01+.03 DSI 0.89 ODSCC TSP AXIAL In Service via APC 3

5 12 H01+.00 DSI 0.85 ODSCC TSP AXIAL In Service via APC 3

5 17 H02+.00 DSI 0.73 ODSCC TSP AXIAL In Service via APC 3

5 18 H01-.06 DSI 0.31 ODSCC TSP AXIAL In Service via APC 3

5 22 H01-.03 DSI 1.06 ODSCC TSP AXIAL In Service via APC 3

5 22 H01+.13 SAI 0.12 ODSCC TSP AXIAL In Service via APC 3

5 22 H01+.14 SAI 0.1 ODSCC TSP AXIAL In Service via APC 3

5 85 C01-.03 DSI 0.15 ODSCC TSP AXIAL In Service via APC 3

6 1

H01-.06 DSI 0.89 ODSCC TSP AXIAL In Service via APC 3

6 5

H01+.12 DSI 0.52 ODSCC TSP AXIAL In Service via APC 3

6 10 H01+.00 DSI 1.25 ODSCC TSP AXIAL In Service via APC 3

6 10 H01+.20 SAI 0.16 ODSCC TSP AXIAL In Service via APC 3

6 11 H01+.03 DSI 0.41 ODSCC TSP AXIAL In Service via APC 3

6 30 H01+.06 DSI 1.22 ODSCC TSP AXIAL In Service via APC 3

6 30 H01+.01 SAI 0.23 ODSCC TSP AXIAL In Service via APC 3

6 30 H01+.22 SAI 0.19 ODSCC TSP AXIAL In Service via APC 3

6 30 H01+.31 SAI 0.12 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 37 of 88 3

6 37 H02-.03 DSI 0.74 ODSCC TSP AXIAL In Service via APC 3

6 38 H01+.00 DSI 1.15 ODSCC TSP AXIAL In Service via APC 3

6 38 H01+.26 SAI 0.21 ODSCC TSP AXIAL In Service via APC 3

6 38 H02+.06 DSI 0.38 ODSCC TSP AXIAL In Service via APC 3

6 38 H03+.00 DSI 0.59 ODSCC TSP AXIAL In Service via APC 3

6 40 H05-.06 DSI 0.4 ODSCC TSP AXIAL In Service via APC 3

6 50 H01+.06 DSI 0.45 ODSCC TSP AXIAL In Service via APC 3

6 77 H02-.06 DSI 0.29 ODSCC TSP AXIAL In Service via APC 3

6 79 H02+.00 DSI 0.37 ODSCC TSP AXIAL In Service via APC 3

6 79 H03-.03 DSI 0.41 ODSCC TSP AXIAL In Service via APC 3

7 1

H02+.00 DSI 1.11 ODSCC TSP AXIAL In Service via APC 3

7 14 H01+.00 DSI 1.12 ODSCC TSP AXIAL In Service via APC 3

7 14 H01+.21 SAI 0.22 ODSCC TSP AXIAL In Service via APC 3

7 14 H02-.06 DSI 0.69 ODSCC TSP AXIAL In Service via APC 3

7 24 H02+.03 DSI 0.97 ODSCC TSP AXIAL In Service via APC 3

7 25 H01+.00 DSI 0.88 ODSCC TSP AXIAL In Service via APC 3

7 25 H02+.00 DSI 0.68 ODSCC TSP AXIAL In Service via APC 3

7 29 H01+.03 DSI 0.85 ODSCC TSP AXIAL In Service via APC 3

7 29 H01+.15 SAI 0.15 ODSCC TSP AXIAL In Service via APC 3

7 29 H01+.21 SAI 0.14 ODSCC TSP AXIAL In Service via APC 3

7 29 H01+.24 SAI 0.12 ODSCC TSP AXIAL In Service via APC 3

7 35 H03+.00 DSI 0.66 ODSCC TSP AXIAL In Service via APC 3

7 38 H02+.00 DSI 0.44 ODSCC TSP AXIAL In Service via APC 3

7 42 H04-.06 DSI 0.95 ODSCC TSP AXIAL In Service via APC 3

7 56 H01-.12 DSI 0.62 ODSCC TSP AXIAL In Service via APC 3

7 56 H02+.18 DSI 1.01 ODSCC TSP AXIAL In Service via APC 3

7 58 H02+.06 DSI 0.52 ODSCC TSP AXIAL In Service via APC 3

7 58 H02+.30 SAI 0.27 ODSCC TSP AXIAL In Service via APC 3

7 60 H01-.12 DSI 0.72 ODSCC TSP AXIAL In Service via APC 3

7 61 H01+.06 DSI 0.56 ODSCC TSP AXIAL In Service via APC 3

7 64 H01-.08 DSI 0.82 ODSCC TSP AXIAL In Service via APC 3

7 70 H01-.05 DSI 0.76 ODSCC TSP AXIAL In Service via APC 3

7 71 H01+.02 DSI 0.89 ODSCC TSP AXIAL In Service via APC 3

7 71 H02+.01 DSI 1.52 ODSCC TSP AXIAL In Service via APC 3

7 71 H02+.24 SAI 0.3 ODSCC TSP AXIAL In Service via APC 3

7 71 H02+.28 SAI 0.26 ODSCC TSP AXIAL In Service via APC 3

7 71 H03+.01 DSI 0.47 ODSCC TSP AXIAL In Service via APC 3

7 72 H01+.02 DSI 0.63 ODSCC TSP AXIAL In Service via APC 3

7 72 H02+.00 DSI 1.16 ODSCC TSP AXIAL In Service via APC 3

7 73 H02-.02 DSI 0.33 ODSCC TSP AXIAL In Service via APC 3

7 81 H06-.09 DSI 0.34 ODSCC TSP AXIAL In Service via APC 3

7 91 H02-.05 DSI 0.9 ODSCC TSP AXIAL In Service via APC 3

7 92 H01-.11 DSI 0.46 ODSCC TSP AXIAL In Service via APC 3

7 92 H03+.05 DSI 0.88 ODSCC TSP AXIAL In Service via APC 3

7 93 H01-.03 DSI 0.63 ODSCC TSP AXIAL In Service via APC 3

7 93 H02+.00 DSI 1.45 ODSCC TSP AXIAL In Service via APC 3

7 93 H02+.12 SAI 0.25 ODSCC TSP AXIAL In Service via APC 3

7 93 H03-.08 DSI 0.46 ODSCC TSP AXIAL In Service via APC 3

7 94 H03-.06 DSI 0.56 ODSCC TSP AXIAL In Service via APC 3

8 6

H03-.03 DSI 0.44 ODSCC TSP AXIAL In Service via APC 3

8 7

H03+.03 DSI 1.01 ODSCC TSP AXIAL In Service via APC 3

8 7

H03+.23 SAI 0.33 ODSCC TSP AXIAL In Service via APC 3

8 15 H02+.03 DSI 0.56 ODSCC TSP AXIAL In Service via APC 3

8 18 H03+.00 DSI 0.78 ODSCC TSP AXIAL In Service via APC 3

8 18 H05+.00 DSI 0.9 ODSCC TSP AXIAL In Service via APC 3

8 22 H03+.03 DSI 0.77 ODSCC TSP AXIAL In Service via APC 3

8 24 H03+.00 DSI 0.56 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 38 of 88 3

8 28 H01-.03 DSI 0.79 ODSCC TSP AXIAL In Service via APC 3

8 49 H01+.06 DSI 0.81 ODSCC TSP AXIAL In Service via APC 3

8 49 H01+.14 SAI 0.12 ODSCC TSP AXIAL In Service via APC 3

8 50 H01-.03 DSI 0.47 ODSCC TSP AXIAL In Service via APC 3

8 51 H01-.15 DSI 0.5 ODSCC TSP AXIAL In Service via APC 3

8 52 H01-.21 DSI 0.76 ODSCC TSP AXIAL In Service via APC 3

8 55 H02-.03 DSI 0.3 ODSCC TSP AXIAL In Service via APC 3

8 57 H04-.06 DSI 0.39 ODSCC TSP AXIAL In Service via APC 3

8 59 H01-.09 DSI 0.72 ODSCC TSP AXIAL In Service via APC 3

8 63 H01-.03 DSI 0.76 ODSCC TSP AXIAL In Service via APC 3

8 63 H02-.15 DSI 1.07 ODSCC TSP AXIAL In Service via APC 3

8 63 H02+.11 SAI 0.2 ODSCC TSP AXIAL In Service via APC 3

8 63 H02+.17 SAI 0.23 ODSCC TSP AXIAL In Service via APC 3

8 64 H01-.09 DSI 0.71 ODSCC TSP AXIAL In Service via APC 3

8 67 H02-.06 DSI 0.66 ODSCC TSP AXIAL In Service via APC 3

8 69 H01-.03 DSI 1.02 ODSCC TSP AXIAL In Service via APC 3

8 69 H01+.15 SAI 0.19 ODSCC TSP AXIAL In Service via APC 3

8 70 H03-.06 DSI 0.81 ODSCC TSP AXIAL In Service via APC 3

8 70 H05+.20 DSI 0.41 ODSCC TSP AXIAL In Service via APC 3

9 4

H01+.00 DSI 0.7 ODSCC TSP AXIAL In Service via APC 3

9 4

H01+.26 SAI 0.19 ODSCC TSP AXIAL In Service via APC 3

9 5

H01+.03 DSI 1.01 ODSCC TSP AXIAL In Service via APC 3

9 5

H01+.21 SAI 0.2 ODSCC TSP AXIAL In Service via APC 3

9 6

H01+.15 DSI 0.24 ODSCC TSP AXIAL In Service via APC 3

9 7

H01+.00 DSI 0.82 ODSCC TSP AXIAL In Service via APC 3

9 8

H01-.03 DSI 1.24 ODSCC TSP AXIAL In Service via APC 3

9 8

H01+.30 SAI 0.17 ODSCC TSP AXIAL In Service via APC 3

9 10 H03+.03 DSI 0.37 ODSCC TSP AXIAL In Service via APC 3

9 11 H01+.00 DSI 1.21 ODSCC TSP AXIAL In Service via APC 3

9 11 H01+.30 SAI 0.18 ODSCC TSP AXIAL In Service via APC 3

9 12 H01-.06 DSI 0.9 ODSCC TSP AXIAL In Service via APC 3

9 13 H02+.00 DSI 0.88 ODSCC TSP AXIAL In Service via APC 3

9 13 H05-.03 DSI 0.94 ODSCC TSP AXIAL In Service via APC 3

9 14 H01-.03 DSI 1.06 ODSCC TSP AXIAL In Service via APC 3

9 14 H01+.16 SAI 0.16 ODSCC TSP AXIAL In Service via APC 3

9 14 H01+.24 SAI 0.11 ODSCC TSP AXIAL In Service via APC 3

9 14 H01+.28 SAI 0.32 ODSCC TSP AXIAL In Service via APC 3

9 15 H03-.03 DSI 0.97 ODSCC TSP AXIAL In Service via APC 3

9 16 H01+.00 DSI 0.91 ODSCC TSP AXIAL In Service via APC 3

9 20 H02-.06 DSI 0.82 ODSCC TSP AXIAL In Service via APC 3

9 21 H02+.03 DSI 1.05 ODSCC TSP AXIAL In Service via APC 3

9 21 H02+.15 SAI 0.13 ODSCC TSP AXIAL In Service via APC 3

9 21 H02+.22 SAI 0.14 ODSCC TSP AXIAL In Service via APC 3

9 23 H03-.03 DSI 1.06 ODSCC TSP AXIAL In Service via APC 3

9 23 H03+.06 SAI 0.1 ODSCC TSP AXIAL In Service via APC 3

9 40 H02-.06 DSI 0.41 ODSCC TSP AXIAL In Service via APC 3

9 41 H01+.06 DSI 0.94 ODSCC TSP AXIAL In Service via APC 3

9 48 H01+.03 DSI 1.6 ODSCC TSP AXIAL In Service via APC 3

9 48 H01+.13 SAI 0.15 ODSCC TSP AXIAL In Service via APC 3

9 48 H01+.25 SAI 0.49 ODSCC TSP AXIAL In Service via APC 3

9 48 H01+.32 SAI 0.5 ODSCC TSP AXIAL In Service via APC 3

9 48 H02-.11 DSI 0.99 ODSCC TSP AXIAL In Service via APC 3

9 48 H02-.06 DSI 0.82 ODSCC TSP AXIAL In Service via APC 3

9 50 H01+.06 DSI 0.82 ODSCC TSP AXIAL In Service via APC 3

9 51 H01+.11 DSI 1.22 ODSCC TSP AXIAL In Service via APC 3

9 51 H01+.23 SAI 0.19 ODSCC TSP AXIAL In Service via APC 3

9 52 H01-.18 DSI 0.23 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 39 of 88 3

10 5

H01+.17 DSI 0.97 ODSCC TSP AXIAL In Service via APC 3

10 6

H03+.28 DSI 0.64 ODSCC TSP AXIAL In Service via APC 3

10 14 H01-.03 DSI 0.78 ODSCC TSP AXIAL In Service via APC 3

10 42 C03+.06 DSI 0.37 ODSCC TSP AXIAL In Service via APC 3

11 5

H03+.00 DSI 0.56 ODSCC TSP AXIAL In Service via APC 3

11 6

H01+.03 DSI 0.77 ODSCC TSP AXIAL In Service via APC 3

11 11 H01+.14 DSI 1.03 ODSCC TSP AXIAL In Service via APC 3

11 11 H01-.10 SAI 0.21 ODSCC TSP AXIAL In Service via APC 3

11 11 H01+.27 SAI 0.22 ODSCC TSP AXIAL In Service via APC 3

11 11 H01+.32 SAI 0.46 ODSCC TSP AXIAL In Service via APC 3

11 16 H03+.03 DSI 0.63 ODSCC TSP AXIAL In Service via APC 3

11 16 H06+.06 DSI 0.4 ODSCC TSP AXIAL In Service via APC 3

11 17 H02+.09 DSI 1.3 ODSCC TSP AXIAL In Service via APC 3

11 17 H02+.10 SAI 0.13 ODSCC TSP AXIAL In Service via APC 3

11 17 H02+.19 SAI 0.19 ODSCC TSP AXIAL In Service via APC 3

11 19 H02+.06 DSI 1.35 ODSCC TSP AXIAL In Service via APC 3

11 27 H01+.03 DSI 0.6 ODSCC TSP AXIAL In Service via APC 3

11 36 H01+.09 DSI 1.66 ODSCC TSP AXIAL In Service via APC 3

11 36 H01+.29 SAI 0.27 ODSCC TSP AXIAL In Service via APC 3

11 37 H01+.12 DSI 1.38 ODSCC TSP AXIAL In Service via APC 3

11 37 H01-.13 SAI 0.13 ODSCC TSP AXIAL In Service via APC 3

11 37 H01+.23 SAI 0.26 ODSCC TSP AXIAL In Service via APC 3

11 37 H01+.24 SAI 0.15 ODSCC TSP AXIAL In Service via APC 3

11 46 H02+.03 DSI 1.08 ODSCC TSP AXIAL In Service via APC 3

11 46 H02+.12 SAI 0.1 ODSCC TSP AXIAL In Service via APC 3

12 22 H02+.11 DSI 0.78 ODSCC TSP AXIAL In Service via APC 3

12 27 H01+.00 DSI 0.5 ODSCC TSP AXIAL In Service via APC 3

12 35 H01+.03 DSI 1.07 ODSCC TSP AXIAL In Service via APC 3

12 35 H01+.28 SAI 0.28 ODSCC TSP AXIAL In Service via APC 3

12 35 H02+.03 DSI 0.54 ODSCC TSP AXIAL In Service via APC 3

12 35 H03+.12 DSI 0.83 ODSCC TSP AXIAL In Service via APC 3

12 38 H01+.09 DSI 0.87 ODSCC TSP AXIAL In Service via APC 3

12 58 H05+.00 DSI 0.65 ODSCC TSP AXIAL In Service via APC 3

13 3

H01+.12 DSI 1.07 ODSCC TSP AXIAL In Service via APC 3

13 3

H01+.03 SAI 0.07 ODSCC TSP AXIAL In Service via APC 3

13 3

H01+.07 SAI 0.12 ODSCC TSP AXIAL In Service via APC 3

13 3

H01+.18 SAI 0.1 ODSCC TSP AXIAL In Service via APC 3

13 3

H01+.19 SAI 0.19 ODSCC TSP AXIAL In Service via APC 3

13 3

H02+.03 DSI 0.51 ODSCC TSP AXIAL In Service via APC 3

13 5

H03+.06 DSI 0.32 ODSCC TSP AXIAL In Service via APC 3

13 7

H01+.06 DSI 0.85 ODSCC TSP AXIAL In Service via APC 3

13 9

H01+.09 DSI 0.55 ODSCC TSP AXIAL In Service via APC 3

13 10 H02+.11 DSI 0.49 ODSCC TSP AXIAL In Service via APC 3

13 17 H02+.00 DSI 0.6 ODSCC TSP AXIAL In Service via APC 3

13 24 H01+.05 DSI 1.29 ODSCC TSP AXIAL In Service via APC 3

13 24 H01-.02 SAI 0.16 ODSCC TSP AXIAL In Service via APC 3

13 24 H01+.21 SAI 0.14 ODSCC TSP AXIAL In Service via APC 3

13 24 H02+.06 DSI 0.7 ODSCC TSP AXIAL In Service via APC 3

13 29 H01+.00 DSI 0.78 ODSCC TSP AXIAL In Service via APC 3

13 29 H02-.06 DSI 1.05 ODSCC TSP AXIAL In Service via APC 3

13 29 H02+.24 SAI 0.22 ODSCC TSP AXIAL In Service via APC 3

13 30 H01+.06 DSI 1.08 ODSCC TSP AXIAL In Service via APC 3

13 36 H01+.03 DSI 1.19 ODSCC TSP AXIAL In Service via APC 3

13 36 H01+.14 SAI 0.1 ODSCC TSP AXIAL In Service via APC 3

13 44 H02+.00 DSI 1.05 ODSCC TSP AXIAL In Service via APC 3

13 53 H01-.03 DSI 1.02 ODSCC TSP AXIAL In Service via APC 3

13 54 H01+.06 DSI 0.61 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 40 of 88 3

14 3

H03+.06 DSI 0.41 ODSCC TSP AXIAL In Service via APC 3

14 4

H01+.08 DSI 0.71 ODSCC TSP AXIAL In Service via APC 3

14 6

H03+.06 DSI 0.8 ODSCC TSP AXIAL In Service via APC 3

14 11 H03+.06 DSI 0.35 ODSCC TSP AXIAL In Service via APC 3

14 14 H01+.14 DSI 0.64 ODSCC TSP AXIAL In Service via APC 3

14 16 H05+.11 DSI 0.96 ODSCC TSP AXIAL In Service via APC 3

14 18 H01+.03 DSI 1.12 ODSCC TSP AXIAL In Service via APC 3

14 18 H01+.09 SAI 0.1 ODSCC TSP AXIAL In Service via APC 3

14 18 H01+.18 SAI 0.13 ODSCC TSP AXIAL In Service via APC 3

14 18 H04+.11 DSI 0.28 ODSCC TSP AXIAL In Service via APC 3

14 20 H02+.03 DSI 0.84 ODSCC TSP AXIAL In Service via APC 3

14 21 H02+.00 DSI 0.74 ODSCC TSP AXIAL In Service via APC 3

14 26 H06+.06 DSI 0.86 ODSCC TSP AXIAL In Service via APC 3

14 39 H01-.09 DSI 1.87 ODSCC TSP AXIAL In Service via APC 3

14 39 H01-.10 SAI 0.16 ODSCC TSP AXIAL In Service via APC 3

14 39 H01-.08 SAI 0.18 ODSCC TSP AXIAL In Service via APC 3

14 39 H01+.00 SAI 0.21 ODSCC TSP AXIAL In Service via APC 3

14 39 H01+.04 SAI 0.19 ODSCC TSP AXIAL In Service via APC 3

14 39 H01+.23 SAI 0.42 ODSCC TSP AXIAL In Service via APC 3

14 39 H01+.26 SAI 0.25 ODSCC TSP AXIAL In Service via APC 3

14 39 H01+.29 SAI 0.35 ODSCC TSP AXIAL In Service via APC 3

14 39 H03+.03 DSI 0.84 ODSCC TSP AXIAL In Service via APC 3

14 39 H04-.03 DSI 0.82 ODSCC TSP AXIAL In Service via APC 3

14 41 H01+.11 DSI 0.58 ODSCC TSP AXIAL In Service via APC 3

14 41 H02+.12 DSI 0.46 ODSCC TSP AXIAL In Service via APC 3

14 52 H01+.03 DSI 0.83 ODSCC TSP AXIAL In Service via APC 3

14 79 H02+.00 DSI 0.42 ODSCC TSP AXIAL In Service via APC 3

15 3

H01+.15 DSI 1.21 ODSCC TSP AXIAL In Service via APC 3

15 3

H01+.23 SAI 0.15 ODSCC TSP AXIAL In Service via APC 3

15 3

H01+.34 SAI 0.3 ODSCC TSP AXIAL In Service via APC 3

15 3

H02+.03 DSI 1.09 ODSCC TSP AXIAL In Service via APC 3

15 3

H02-.07 SAI 0.15 ODSCC TSP AXIAL In Service via APC 3

15 3

H03+.00 DSI 0.97 ODSCC TSP AXIAL In Service via APC 3

15 6

H01+.08 DSI 0.97 ODSCC TSP AXIAL In Service via APC 3

15 6

H02-.06 DSI 0.76 ODSCC TSP AXIAL In Service via APC 3

15 15 H01+.09 DSI 0.84 ODSCC TSP AXIAL In Service via APC 3

15 16 H01+.00 DSI 1.04 ODSCC TSP AXIAL In Service via APC 3

15 16 H01+.24 SAI 0.1 ODSCC TSP AXIAL In Service via APC 3

15 16 H01+.27 SAI 0.32 ODSCC TSP AXIAL In Service via APC 3

15 18 H02+.00 DSI 1.44 ODSCC TSP AXIAL In Service via APC 3

15 18 H02+.13 SAI 0.13 ODSCC TSP AXIAL In Service via APC 3

15 26 H01+.05 DSI 0.93 ODSCC TSP AXIAL In Service via APC 3

15 29 H02+.03 DSI 0.84 ODSCC TSP AXIAL In Service via APC 3

15 30 H01+.09 DSI 0.99 ODSCC TSP AXIAL In Service via APC 3

15 33 H03+.03 DSI 0.64 ODSCC TSP AXIAL In Service via APC 3

15 33 H04-.09 DSI 0.43 ODSCC TSP AXIAL In Service via APC 3

15 36 H02+.03 DSI 0.29 ODSCC TSP AXIAL In Service via APC 3

15 37 H01+.03 DSI 0.9 ODSCC TSP AXIAL In Service via APC 3

15 39 H01+.00 DSI 0.6 ODSCC TSP AXIAL In Service via APC 3

15 43 H01+.00 DSI 0.34 ODSCC TSP AXIAL In Service via APC 3

15 43 H02+.09 DSI 0.42 ODSCC TSP AXIAL In Service via APC 3

15 71 H05+.06 DSI 0.36 ODSCC TSP AXIAL In Service via APC 3

16 4

H01+.00 DSI 1.81 ODSCC TSP AXIAL In Service via APC 3

16 4

H01+.36 SAI 0.21 ODSCC TSP AXIAL In Service via APC 3

16 4

H02+.08 DSI 0.88 ODSCC TSP AXIAL In Service via APC 3

16 5

H04+.00 DSI 0.39 ODSCC TSP AXIAL In Service via APC 3

16 21 H01+.06 DSI 1.24 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 41 of 88 3

16 21 H01+.27 SAI 0.16 ODSCC TSP AXIAL In Service via APC 3

16 21 H02+.03 DSI 0.71 ODSCC TSP AXIAL In Service via APC 3

16 22 H01+.08 DSI 0.76 ODSCC TSP AXIAL In Service via APC 3

16 24 H01+.03 DSI 0.53 ODSCC TSP AXIAL In Service via APC 3

16 40 H01+.00 DSI 0.99 ODSCC TSP AXIAL In Service via APC 3

16 41 H01+.09 DSI 0.67 ODSCC TSP AXIAL In Service via APC 3

16 54 H01-.06 DSI 1

ODSCC TSP AXIAL In Service via APC 3

16 54 H01+.10 SAI 0.11 ODSCC TSP AXIAL In Service via APC 3

17 6

H02+.00 DSI 0.85 ODSCC TSP AXIAL In Service via APC 3

17 11 H01+.23 DSI 0.72 ODSCC TSP AXIAL In Service via APC 3

17 12 H01+.22 DSI 0.75 ODSCC TSP AXIAL In Service via APC 3

17 13 H01+.11 DSI 0.64 ODSCC TSP AXIAL In Service via APC 3

17 20 H01+.16 DSI 0.63 ODSCC TSP AXIAL In Service via APC 3

17 22 H01+.11 DSI 1.01 ODSCC TSP AXIAL In Service via APC 3

17 22 H01+.21 SAI 0.2 ODSCC TSP AXIAL In Service via APC 3

17 37 H01+.09 DSI 0.89 ODSCC TSP AXIAL In Service via APC 3

17 39 H02+.06 DSI 0.44 ODSCC TSP AXIAL In Service via APC 3

17 40 H01+.00 DSI 1.26 ODSCC TSP AXIAL In Service via APC 3

17 40 H01+.13 SAI 0.15 ODSCC TSP AXIAL In Service via APC 3

17 47 H01-.03 DSI 0.95 ODSCC TSP AXIAL In Service via APC 3

17 50 H01-.06 DSI 0.6 ODSCC TSP AXIAL In Service via APC 3

17 53 H01+.03 DSI 1.24 ODSCC TSP AXIAL In Service via APC 3

17 53 H01+.24 SAI 0.09 ODSCC TSP AXIAL In Service via APC 3

17 82 H05+.00 DSI 0.38 ODSCC TSP AXIAL In Service via APC 3

17 87 H01+.03 DSI 0.34 ODSCC TSP AXIAL In Service via APC 3

17 87 H04-.15 DSI 0.52 ODSCC TSP AXIAL In Service via APC 3

18 8

H01+.03 DSI 0.41 ODSCC TSP AXIAL In Service via APC 3

18 18 H01+.06 DSI 0.93 ODSCC TSP AXIAL In Service via APC 3

18 21 H01+.09 DSI 0.84 ODSCC TSP AXIAL In Service via APC 3

18 35 H01+.03 DSI 1.26 ODSCC TSP AXIAL In Service via APC 3

18 35 H01+.33 SAI 0.35 ODSCC TSP AXIAL In Service via APC 3

18 35 H01+.34 SAI 0.11 ODSCC TSP AXIAL In Service via APC 3

18 37 H01+.09 DSI 1.02 ODSCC TSP AXIAL In Service via APC 3

18 37 H01+.08 SAI 0.11 ODSCC TSP AXIAL In Service via APC 3

18 37 H01+.30 SAI 0.36 ODSCC TSP AXIAL In Service via APC 3

18 37 H02-.06 DSI 0.86 ODSCC TSP AXIAL In Service via APC 3

18 38 H01+.09 DSI 1.03 ODSCC TSP AXIAL In Service via APC 3

18 38 H01+.15 SAI 0.17 ODSCC TSP AXIAL In Service via APC 3

18 38 H01+.25 SAI 0.31 ODSCC TSP AXIAL In Service via APC 3

18 38 H01+.36 SAI 0.37 ODSCC TSP AXIAL In Service via APC 3

18 45 H01+.09 DSI 0.49 ODSCC TSP AXIAL In Service via APC 3

18 45 H03+.09 DSI 0.28 ODSCC TSP AXIAL In Service via APC 3

18 53 H05-.03 DSI 0.46 ODSCC TSP AXIAL In Service via APC 3

18 81 H03+.06 DSI 0.31 ODSCC TSP AXIAL In Service via APC 3

18 89 H01+.00 DSI 0.31 ODSCC TSP AXIAL In Service via APC 3

19 6

H01+.06 DSI 0.36 ODSCC TSP AXIAL In Service via APC 3

19 10 H01+.08 DSI 0.71 ODSCC TSP AXIAL In Service via APC 3

19 12 H02-.20 DSI 0.89 ODSCC TSP AXIAL In Service via APC 3

19 13 H01+.11 DSI 1.01 ODSCC TSP AXIAL In Service via APC 3

19 13 H01-.10 SAI 0.23 ODSCC TSP AXIAL In Service via APC 3

19 13 H01+.15 SAI 0.21 ODSCC TSP AXIAL In Service via APC 3

19 13 H01+.20 SAI 0.34 ODSCC TSP AXIAL In Service via APC 3

19 13 H01+.25 SAI 0.11 ODSCC TSP AXIAL In Service via APC 3

19 13 H01+.27 SAI 0.2 ODSCC TSP AXIAL In Service via APC 3

19 13 H01+.36 SAI 0.3 ODSCC TSP AXIAL In Service via APC 3

19 13 H03+.09 DSI 0.89 ODSCC TSP AXIAL In Service via APC 3

19 17 H01+.12 DSI 0.6 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 42 of 88 3

19 22 H01+.08 DSI 0.92 ODSCC TSP AXIAL In Service via APC 3

19 22 H02+.06 DSI 0.45 ODSCC TSP AXIAL In Service via APC 3

19 37 H01+.09 DSI 1.07 ODSCC TSP AXIAL In Service via APC 3

19 37 H01+.24 SAI 0.1 ODSCC TSP AXIAL In Service via APC 3

19 37 H01+.25 SAI 0.11 ODSCC TSP AXIAL In Service via APC 3

19 39 H01+.14 DSI 0.58 ODSCC TSP AXIAL In Service via APC 3

19 69 H07-.09 DSI 0.24 ODSCC TSP AXIAL In Service via APC 3

20 6

H01+.09 DSI 0.7 ODSCC TSP AXIAL In Service via APC 3

20 12 H01+.17 DSI 1.42 ODSCC TSP AXIAL In Service via APC 3

20 12 H01+.30 SAI 0.15 ODSCC TSP AXIAL In Service via APC 3

20 12 H01+.31 SAI 0.4 ODSCC TSP AXIAL In Service via APC 3

20 12 H01+.34 SAI 0.35 ODSCC TSP AXIAL In Service via APC 3

20 19 H01+.03 DSI 1.34 ODSCC TSP AXIAL In Service via APC 3

20 19 H01+.23 SAI 0.12 ODSCC TSP AXIAL In Service via APC 3

20 19 H01+.25 SAI 0.28 ODSCC TSP AXIAL In Service via APC 3

20 19 H01+.30 SAI 0.1 ODSCC TSP AXIAL In Service via APC 3

20 19 H01+.31 SAI 0.16 ODSCC TSP AXIAL In Service via APC 3

20 26 H02+.06 DSI 1.04 ODSCC TSP AXIAL In Service via APC 3

20 26 H02-.15 SAI 0.09 ODSCC TSP AXIAL In Service via APC 3

20 26 H02+.06 SAI 0.15 ODSCC TSP AXIAL In Service via APC 3

20 28 H01+.17 DSI 1.51 ODSCC TSP AXIAL In Service via APC 3

20 28 H01+.21 SAI 0.18 ODSCC TSP AXIAL In Service via APC 3

20 28 H01+.28 SAI 0.21 ODSCC TSP AXIAL In Service via APC 3

20 29 H01+.00 DSI 1.82 ODSCC TSP AXIAL In Service via APC 3

20 29 H01+.20 SAI 0.12 ODSCC TSP AXIAL In Service via APC 3

20 29 H01+.28 SAI 0.16 ODSCC TSP AXIAL In Service via APC 3

20 29 H01+.29 SAI 0.23 ODSCC TSP AXIAL In Service via APC 3

20 29 H01+.31 SAI 0.45 ODSCC TSP AXIAL In Service via APC 3

20 30 H01+.14 DSI 1

ODSCC TSP AXIAL In Service via APC 3

20 30 H01+.21 SAI 0.25 ODSCC TSP AXIAL In Service via APC 3

20 30 H01+.24 SAI 0.28 ODSCC TSP AXIAL In Service via APC 3

20 30 H01+.27 SAI 0.26 ODSCC TSP AXIAL In Service via APC 3

20 31 H01+.12 DSI 1.31 ODSCC TSP AXIAL In Service via APC 3

20 31 H01+.22 SAI 0.37 ODSCC TSP AXIAL In Service via APC 3

20 31 H01+.23 SAI 0.22 ODSCC TSP AXIAL In Service via APC 3

20 31 H01+.24 SAI 0.18 ODSCC TSP AXIAL In Service via APC 3

20 31 H03+.15 DSI 0.35 ODSCC TSP AXIAL In Service via APC 3

20 32 H01+.12 DSI 1.93 ODSCC TSP AXIAL In Service via APC 3

20 32 H01+.20 SAI 0.27 ODSCC TSP AXIAL In Service via APC 3

20 32 H01+.25 SAI 0.42 ODSCC TSP AXIAL In Service via APC 3

20 32 H01+.28 SAI 0.13 ODSCC TSP AXIAL In Service via APC 3

20 35 H01+.12 DSI 0.46 ODSCC TSP AXIAL In Service via APC 3

20 35 H02+.03 DSI 1.86 ODSCC TSP AXIAL In Service via APC 3

20 35 H02-.11 SAI 0.12 ODSCC TSP AXIAL In Service via APC 3

20 35 H02+.24 SAI 0.54 ODSCC TSP AXIAL In Service via APC 3

20 35 H02+.35 SAI 0.3 ODSCC TSP AXIAL In Service via APC 3

20 35 H03+.00 DSI 0.72 ODSCC TSP AXIAL In Service via APC 3

20 37 H01+.12 DSI 0.96 ODSCC TSP AXIAL In Service via APC 3

20 39 H01-.03 DSI 1.3 ODSCC TSP AXIAL In Service via APC 3

20 39 H01-.04 SAI 0.21 ODSCC TSP AXIAL In Service via APC 3

20 39 H01+.07 SAI 0.35 ODSCC TSP AXIAL In Service via APC 3

20 39 H01+.23 SAI 0.16 ODSCC TSP AXIAL In Service via APC 3

20 47 H01+.11 DSI 1.29 ODSCC TSP AXIAL In Service via APC 3

20 47 H01+.31 SAI 0.15 ODSCC TSP AXIAL In Service via APC 3

20 50 H02-.15 DSI 0.35 ODSCC TSP AXIAL In Service via APC 3

20 71 H03+.03 DSI 0.38 ODSCC TSP AXIAL In Service via APC 3

20 79 H02-.03 DSI 0.34 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 43 of 88 3

20 80 H03+.00 DSI 0.94 ODSCC TSP AXIAL In Service via APC 3

20 80 H06+.00 DSI 0.51 ODSCC TSP AXIAL In Service via APC 3

20 85 H03+.00 DSI 0.3 ODSCC TSP AXIAL In Service via APC 3

20 86 H01+.00 DSI 1.07 ODSCC TSP AXIAL In Service via APC 3

20 88 H01-.06 DSI 0.42 ODSCC TSP AXIAL In Service via APC 3

20 89 H01+.03 DSI 0.56 ODSCC TSP AXIAL In Service via APC 3

21 15 H02+.03 DSI 0.46 ODSCC TSP AXIAL In Service via APC 3

21 20 H02+.06 DSI 0.7 ODSCC TSP AXIAL In Service via APC 3

21 24 H01+.00 DSI 1.41 ODSCC TSP AXIAL In Service via APC 3

21 24 H01+.25 SAI 0.25 ODSCC TSP AXIAL In Service via APC 3

21 24 H01+.31 SAI 0.53 ODSCC TSP AXIAL In Service via APC 3

21 41 H01+.00 DSI 0.33 ODSCC TSP AXIAL In Service via APC 3

21 81 H02-.06 DSI 0.72 ODSCC TSP AXIAL In Service via APC 3

21 81 H03+.00 DSI 0.32 ODSCC TSP AXIAL In Service via APC 3

21 84 H04+.00 DSI 0.48 ODSCC TSP AXIAL In Service via APC 3

21 88 H01+.03 DSI 0.27 ODSCC TSP AXIAL In Service via APC 3

21 89 H03-.03 DSI 0.94 ODSCC TSP AXIAL In Service via APC 3

22 7

H01+.06 DSI 0.51 ODSCC TSP AXIAL In Service via APC 3

22 7

H01+.06 DSI 0.47 ODSCC TSP AXIAL In Service via APC 3

22 21 H01+.12 DSI 0.47 ODSCC TSP AXIAL In Service via APC 3

22 23 H01+.09 DSI 0.41 ODSCC TSP AXIAL In Service via APC 3

22 26 H02+.06 DSI 1.05 ODSCC TSP AXIAL In Service via APC 3

22 28 H02+.00 DSI 1.48 ODSCC TSP AXIAL In Service via APC 3

22 28 H02+.13 SAI 0.1 ODSCC TSP AXIAL In Service via APC 3

22 29 H01+.09 DSI 0.91 ODSCC TSP AXIAL In Service via APC 3

22 38 H01+.18 DSI 0.86 ODSCC TSP AXIAL In Service via APC 3

22 40 H01-.09 DSI 0.69 ODSCC TSP AXIAL In Service via APC 3

22 52 H01+.00 DSI 1.23 ODSCC TSP AXIAL In Service via APC 3

22 52 H01+.30 SAI 0.13 ODSCC TSP AXIAL In Service via APC 3

22 61 H03-.06 DSI 0.65 ODSCC TSP AXIAL In Service via APC 3

22 68 H02+.03 DSI 0.67 ODSCC TSP AXIAL In Service via APC 3

23 13 H01+.11 DSI 1.57 ODSCC TSP AXIAL In Service via APC 3

23 13 H01+.21 SAI 0.09 ODSCC TSP AXIAL In Service via APC 3

23 13 H01+.29 SAI 0.15 ODSCC TSP AXIAL In Service via APC 3

23 13 H01+.33 SAI 0.59 ODSCC TSP AXIAL In Service via APC 3

23 14 H03+.08 DSI 0.76 ODSCC TSP AXIAL In Service via APC 3

23 22 H01+.27 DSI 0.73 ODSCC TSP AXIAL In Service via APC 3

23 26 H02-.21 DSI 1.39 ODSCC TSP AXIAL In Service via APC 3

23 26 H02+.20 SAI 0.07 ODSCC TSP AXIAL In Service via APC 3

23 26 H02+.29 SAI 0.12 ODSCC TSP AXIAL In Service via APC 3

23 30 H01+.06 DSI 1.25 ODSCC TSP AXIAL In Service via APC 3

23 30 H01+.23 SAI 0.16 ODSCC TSP AXIAL In Service via APC 3

23 30 H01+.24 SAI 0.19 ODSCC TSP AXIAL In Service via APC 3

23 30 H01+.28 SAI 0.1 ODSCC TSP AXIAL In Service via APC 3

23 30 H01+.30 SAI 0.42 ODSCC TSP AXIAL In Service via APC 3

23 38 H01+.03 DSI 1.54 ODSCC TSP AXIAL In Service via APC 3

23 38 H01+.31 SAI 0.57 ODSCC TSP AXIAL In Service via APC 3

23 44 H01-.06 DSI 0.4 ODSCC TSP AXIAL In Service via APC 3

23 51 H04-.15 DSI 2.01 ODSCC TSP AXIAL PLUGGED 3

23 51 H04+.30 SAI 1.01 ODSCC TSP AXIAL PLUGGED 3

23 60 H02-.03 DSI 0.45 ODSCC TSP AXIAL In Service via APC 3

23 75 H03+.00 DSI 0.43 ODSCC TSP AXIAL In Service via APC 3

24 10 H01+.06 DSI 0.88 ODSCC TSP AXIAL In Service via APC 3

24 12 H01+.11 DSI 1.58 ODSCC TSP AXIAL In Service via APC 3

24 12 H01+.22 SAI 0.1 ODSCC TSP AXIAL In Service via APC 3

24 12 H01+.23 SAI 0.1 ODSCC TSP AXIAL In Service via APC 3

24 12 H01+.28 SAI 0.31 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 44 of 88 3

24 12 H01+.29 SAI 0.37 ODSCC TSP AXIAL In Service via APC 3

24 12 H01+.30 SAI 0.11 ODSCC TSP AXIAL In Service via APC 3

24 12 H02+.03 DSI 0.5 ODSCC TSP AXIAL In Service via APC 3

24 13 H02+.09 DSI 0.59 ODSCC TSP AXIAL In Service via APC 3

24 16 H01+.11 DSI 1.28 ODSCC TSP AXIAL In Service via APC 3

24 16 H01+.32 SAI 0.39 ODSCC TSP AXIAL In Service via APC 3

24 16 H01+.33 SAI 0.22 ODSCC TSP AXIAL In Service via APC 3

24 16 H02+.03 DSI 0.69 ODSCC TSP AXIAL In Service via APC 3

24 19 H01+.06 DSI 0.97 ODSCC TSP AXIAL In Service via APC 3

24 21 H03+.12 DSI 0.81 ODSCC TSP AXIAL In Service via APC 3

24 21 H05+.00 DSI 1.26 ODSCC TSP AXIAL In Service via APC 3

24 23 H02+.12 DSI 0.43 ODSCC TSP AXIAL In Service via APC 3

24 23 H03-.03 DSI 0.85 ODSCC TSP AXIAL In Service via APC 3

24 25 H01+.09 DSI 0.96 ODSCC TSP AXIAL In Service via APC 3

24 29 H01+.00 DSI 1.64 ODSCC TSP AXIAL In Service via APC 3

24 29 H01+.10 SAI 0.06 ODSCC TSP AXIAL In Service via APC 3

24 29 H01+.22 SAI 0.38 ODSCC TSP AXIAL In Service via APC 3

24 29 H01+.25 SAI 0.15 ODSCC TSP AXIAL In Service via APC 3

24 35 H01+.00 DSI 0.8 ODSCC TSP AXIAL In Service via APC 3

25 8

H01+.12 DSI 1.94 ODSCC TSP AXIAL In Service via APC 3

25 8

H01+.29 SAI 0.11 ODSCC TSP AXIAL In Service via APC 3

25 8

H01+.30 SAI 0.07 ODSCC TSP AXIAL In Service via APC 3

25 8

H01+.31 SAI 0.27 ODSCC TSP AXIAL In Service via APC 3

25 8

H01+.32 SAI 0.13 ODSCC TSP AXIAL In Service via APC 3

25 14 H04+.09 DSI 0.9 ODSCC TSP AXIAL In Service via APC 3

25 18 H01+.06 DSI 1.22 ODSCC TSP AXIAL In Service via APC 3

25 18 H01+.25 SAI 0.24 ODSCC TSP AXIAL In Service via APC 3

25 18 H01+.26 SAI 0.53 ODSCC TSP AXIAL In Service via APC 3

25 21 H01+.14 DSI 0.32 ODSCC TSP AXIAL In Service via APC 3

25 24 H01+.00 DSI 0.77 ODSCC TSP AXIAL In Service via APC 3

25 24 H02+.08 DSI 0.77 ODSCC TSP AXIAL In Service via APC 3

25 26 H02+.06 DSI 1.19 ODSCC TSP AXIAL In Service via APC 3

25 26 H02+.29 SAI 0.24 ODSCC TSP AXIAL In Service via APC 3

25 35 H01+.17 DSI 0.54 ODSCC TSP AXIAL In Service via APC 3

25 49 H01-.06 DSI 0.82 ODSCC TSP AXIAL In Service via APC 3

25 52 H02-.06 DSI 0.51 ODSCC TSP AXIAL In Service via APC 3

25 72 H02+.00 DSI 0.32 ODSCC TSP AXIAL In Service via APC 3

25 81 H02+.03 DSI 0.55 ODSCC TSP AXIAL In Service via APC 3

26 9

H01+.14 DSI 1.23 ODSCC TSP AXIAL In Service via APC 3

26 9

H01+.35 SAI 0.23 ODSCC TSP AXIAL In Service via APC 3

26 12 H01+.00 DSI 0.28 ODSCC TSP AXIAL In Service via APC 3

26 14 H01+.03 DSI 1.9 ODSCC TSP AXIAL In Service via APC 3

26 14 H01+.26 SAI 0.32 ODSCC TSP AXIAL In Service via APC 3

26 14 H01+.28 SAI 0.09 ODSCC TSP AXIAL In Service via APC 3

26 14 H01+.30 SAI 0.13 ODSCC TSP AXIAL In Service via APC 3

26 14 H01+.34 SAI 0.1 ODSCC TSP AXIAL In Service via APC 3

26 16 H02+.08 DSI 1.02 ODSCC TSP AXIAL In Service via APC 3

26 17 H02+.03 DSI 1.01 ODSCC TSP AXIAL In Service via APC 3

26 17 H02+.03 SAI 0.12 ODSCC TSP AXIAL In Service via APC 3

26 17 H02+.17 SAI 0.18 ODSCC TSP AXIAL In Service via APC 3

26 17 H02+.26 SAI 0.11 ODSCC TSP AXIAL In Service via APC 3

26 20 H02+.11 DSI 0.79 ODSCC TSP AXIAL In Service via APC 3

26 22 H04+.09 DSI 0.56 ODSCC TSP AXIAL In Service via APC 3

26 22 H05+.09 DSI 0.84 ODSCC TSP AXIAL In Service via APC 3

26 22 H06+.06 DSI 0.68 ODSCC TSP AXIAL In Service via APC 3

26 23 H01+.23 DSI 0.87 ODSCC TSP AXIAL In Service via APC 3

26 24 H01+.06 DSI 0.42 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 45 of 88 3

26 25 H02+.06 DSI 1.06 ODSCC TSP AXIAL In Service via APC 3

26 25 H02+.32 SAI 0.2 ODSCC TSP AXIAL In Service via APC 3

26 27 H01+.03 DSI 0.51 ODSCC TSP AXIAL In Service via APC 3

26 28 H01+.03 DSI 1.81 ODSCC TSP AXIAL In Service via APC 3

26 28 H01+.18 SAI 0.1 ODSCC TSP AXIAL In Service via APC 3

26 28 H01+.29 SAI 0.15 ODSCC TSP AXIAL In Service via APC 3

26 28 H01+.30 SAI 0.24 ODSCC TSP AXIAL In Service via APC 3

26 29 H01-.09 DSI 0.64 ODSCC TSP AXIAL In Service via APC 3

26 29 H03-.09 DSI 1.35 ODSCC TSP AXIAL In Service via APC 3

26 29 H03-.06 SAI 0.09 ODSCC TSP AXIAL In Service via APC 3

26 29 H03-.03 SAI 0.12 ODSCC TSP AXIAL In Service via APC 3

26 29 H03+.26 SAI 0.1 ODSCC TSP AXIAL In Service via APC 3

26 30 H02+.00 DSI 0.48 ODSCC TSP AXIAL In Service via APC 3

26 35 H01+.03 DSI 1.22 ODSCC TSP AXIAL In Service via APC 3

26 35 H01+.27 SAI 0.4 ODSCC TSP AXIAL In Service via APC 3

26 81 H02-.09 DSI 1.15 ODSCC TSP AXIAL In Service via APC 3

26 81 H02+.09 SAI 0.11 ODSCC TSP AXIAL In Service via APC 3

27 15 H01+.03 DSI 0.87 ODSCC TSP AXIAL In Service via APC 3

27 16 H01+.08 DSI 2.04 ODSCC TSP AXIAL PLUGGED 3

27 16 H01+.24 SAI 0.14 ODSCC TSP AXIAL PLUGGED 3

27 16 H01+.28 SAI 0.14 ODSCC TSP AXIAL PLUGGED 3

27 16 H02+.06 DSI 1.14 ODSCC TSP AXIAL In Service via APC 3

27 16 H02+.03 SAI 0.11 ODSCC TSP AXIAL In Service via APC 3

27 16 H02+.31 SAI 0.15 ODSCC TSP AXIAL In Service via APC 3

27 18 H01+.08 DSI 0.79 ODSCC TSP AXIAL In Service via APC 3

27 18 H03+.14 DSI 0.46 ODSCC TSP AXIAL In Service via APC 3

27 24 H02+.11 DSI 0.68 ODSCC TSP AXIAL In Service via APC 3

27 26 H01+.08 DSI 0.61 ODSCC TSP AXIAL In Service via APC 3

27 26 H02+.03 DSI 1.31 ODSCC TSP AXIAL In Service via APC 3

27 26 H02+.11 SAI 0.1 ODSCC TSP AXIAL In Service via APC 3

27 26 H02+.12 SAI 0.15 ODSCC TSP AXIAL In Service via APC 3

27 26 H02+.30 SAI 0.12 ODSCC TSP AXIAL In Service via APC 3

27 26 H02+.32 SAI 0.34 ODSCC TSP AXIAL In Service via APC 3

27 27 H01+.23 DSI 0.74 ODSCC TSP AXIAL In Service via APC 3

27 29 H01+.12 DSI 0.57 ODSCC TSP AXIAL In Service via APC 3

27 29 H02+.06 DSI 0.36 ODSCC TSP AXIAL In Service via APC 3

27 30 H02+.06 DSI 1.29 ODSCC TSP AXIAL In Service via APC 3

27 30 H02+.18 SAI 0.15 ODSCC TSP AXIAL In Service via APC 3

27 30 H02+.22 SAI 0.2 ODSCC TSP AXIAL In Service via APC 3

27 30 H02+.35 SAI 0.21 ODSCC TSP AXIAL In Service via APC 3

27 35 H01+.03 DSI 1.05 ODSCC TSP AXIAL In Service via APC 3

27 35 H01+.23 SAI 0.15 ODSCC TSP AXIAL In Service via APC 3

27 35 H01+.34 SAI 0.35 ODSCC TSP AXIAL In Service via APC 3

27 36 H02+.00 DSI 0.69 ODSCC TSP AXIAL In Service via APC 3

27 60 H02+.03 DSI 0.65 ODSCC TSP AXIAL In Service via APC 3

27 63 H02+.00 DSI 0.62 ODSCC TSP AXIAL In Service via APC 3

27 63 H03-.03 DSI 0.99 ODSCC TSP AXIAL In Service via APC 3

27 67 H02-.03 DSI 0.2 ODSCC TSP AXIAL In Service via APC 3

27 68 H02-.03 DSI 0.37 ODSCC TSP AXIAL In Service via APC 3

27 68 H05+.00 DSI 0.18 ODSCC TSP AXIAL In Service via APC 3

27 69 H04-.09 DSI 0.7 ODSCC TSP AXIAL In Service via APC 3

27 79 H02+.00 DSI 0.68 ODSCC TSP AXIAL In Service via APC 3

27 79 H06+.00 DSI 0.33 ODSCC TSP AXIAL In Service via APC 3

27 85 H02+.00 DSI 0.14 ODSCC TSP AXIAL In Service via APC 3

28 14 H01+.08 DSI 0.51 ODSCC TSP AXIAL In Service via APC 3

28 14 H01+.13 SAI 0.12 ODSCC TSP AXIAL In Service via APC 3

28 26 H01+.00 DSI 1.64 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 46 of 88 3

28 26 H01+.13 SAI 0.22 ODSCC TSP AXIAL In Service via APC 3

28 26 H01+.17 SAI 0.26 ODSCC TSP AXIAL In Service via APC 3

28 27 H03+.09 DSI 0.82 ODSCC TSP AXIAL In Service via APC 3

28 84 H01+.00 DSI 0.77 ODSCC TSP AXIAL In Service via APC 3

29 14 H01+.03 DSI 1.17 ODSCC TSP AXIAL In Service via APC 3

29 14 H01-.06 SAI 0.09 ODSCC TSP AXIAL In Service via APC 3

29 14 H01+.05 SAI 0.12 ODSCC TSP AXIAL In Service via APC 3

29 14 H01+.16 SAI 0.08 ODSCC TSP AXIAL In Service via APC 3

29 14 H01+.20 SAI 0.09 ODSCC TSP AXIAL In Service via APC 3

29 14 H01+.24 SAI 0.12 ODSCC TSP AXIAL In Service via APC 3

29 23 H05+.06 DSI 0.33 ODSCC TSP AXIAL In Service via APC 3

29 35 H01+.09 DSI 0.66 ODSCC TSP AXIAL In Service via APC 3

29 50 H03-.03 DSI 0.57 ODSCC TSP AXIAL In Service via APC 3

29 79 C03+.15 DSI 0.23 ODSCC TSP AXIAL In Service via APC 3

30 18 H01+.28 DSI 0.4 ODSCC TSP AXIAL In Service via APC 3

30 21 H01+.03 DSI 0.6 ODSCC TSP AXIAL In Service via APC 3

30 23 H01+.23 DSI 1.56 ODSCC TSP AXIAL In Service via APC 3

30 23 H01+.21 SAI 0.49 ODSCC TSP AXIAL In Service via APC 3

30 23 H01+.22 SAI 0.19 ODSCC TSP AXIAL In Service via APC 3

30 23 H01+.27 SAI 0.63 ODSCC TSP AXIAL In Service via APC 3

30 42 H02+.06 DSI 0.48 ODSCC TSP AXIAL In Service via APC 3

30 42 H03+.00 DSI 0.63 ODSCC TSP AXIAL In Service via APC 3

30 46 H02+.00 DSI 1.3 ODSCC TSP AXIAL In Service via APC 3

30 46 H02+.20 SAI 0.18 ODSCC TSP AXIAL In Service via APC 3

30 46 H03+.09 DSI 0.79 ODSCC TSP AXIAL In Service via APC 3

30 50 H01-.06 DSI 1.05 ODSCC TSP AXIAL In Service via APC 3

30 50 H01+.31 SAI 0.34 ODSCC TSP AXIAL In Service via APC 3

30 50 H03-.03 DSI 0.29 ODSCC TSP AXIAL In Service via APC 3

30 59 H06+.00 DSI 0.41 ODSCC TSP AXIAL In Service via APC 3

31 14 H03+.03 DSI 1.17 ODSCC TSP AXIAL In Service via APC 3

31 20 H01-.03 DSI 0.56 ODSCC TSP AXIAL In Service via APC 3

31 25 H02+.09 DSI 0.47 ODSCC TSP AXIAL In Service via APC 3

31 26 H02+.06 DSI 0.48 ODSCC TSP AXIAL In Service via APC 3

31 26 H03+.06 DSI 0.68 ODSCC TSP AXIAL In Service via APC 3

31 28 H01+.00 DSI 1.85 ODSCC TSP AXIAL In Service via APC 3

31 28 H01+.05 SAI 0.19 ODSCC TSP AXIAL In Service via APC 3

31 28 H01+.24 SAI 0.29 ODSCC TSP AXIAL In Service via APC 3

31 28 H01+.26 SAI 0.13 ODSCC TSP AXIAL In Service via APC 3

31 28 H04-.22 DSI 0.96 ODSCC TSP AXIAL In Service via APC 3

31 30 H01+.00 DSI 0.76 ODSCC TSP AXIAL In Service via APC 3

31 32 H02+.09 DSI 1.15 ODSCC TSP AXIAL In Service via APC 3

31 32 H02+.22 SAI 0.11 ODSCC TSP AXIAL In Service via APC 3

31 42 H02+.03 DSI 0.46 ODSCC TSP AXIAL In Service via APC 3

31 65 H02+.00 DSI 0.84 ODSCC TSP AXIAL In Service via APC 3

31 76 H01+.00 DSI 0.96 ODSCC TSP AXIAL In Service via APC 3

31 76 H02+.00 DSI 0.63 ODSCC TSP AXIAL In Service via APC 3

32 20 H01+.00 DSI 0.4 ODSCC TSP AXIAL In Service via APC 3

32 21 H01+.09 DSI 0.49 ODSCC TSP AXIAL In Service via APC 3

32 23 H01+.00 DSI 1.99 ODSCC TSP AXIAL In Service via APC 3

32 23 H01+.28 SAI 0.37 ODSCC TSP AXIAL In Service via APC 3

32 25 H02+.14 DSI 0.55 ODSCC TSP AXIAL In Service via APC 3

32 29 H01+.09 DSI 0.95 ODSCC TSP AXIAL In Service via APC 3

32 33 H02+.09 DSI 1.29 ODSCC TSP AXIAL In Service via APC 3

32 33 H02+.19 SAI 0.15 ODSCC TSP AXIAL In Service via APC 3

32 33 H02+.30 SAI 0.15 ODSCC TSP AXIAL In Service via APC 3

32 34 H02+.17 DSI 0.61 ODSCC TSP AXIAL In Service via APC 3

32 34 H03+.00 DSI 1.34 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 47 of 88 3

32 34 H03+.15 SAI 0.14 ODSCC TSP AXIAL In Service via APC 3

32 42 H02+.00 DSI 1.05 ODSCC TSP AXIAL In Service via APC 3

32 42 H02+.30 SAI 0.24 ODSCC TSP AXIAL In Service via APC 3

32 48 H02+.00 DSI 0.29 ODSCC TSP AXIAL In Service via APC 3

32 54 H01+.15 DSI 0.82 ODSCC TSP AXIAL In Service via APC 3

32 54 H02-.06 DSI 0.63 ODSCC TSP AXIAL In Service via APC 3

32 57 H03-.12 DSI 0.46 ODSCC TSP AXIAL In Service via APC 3

32 76 H03-.06 DSI 0.3 ODSCC TSP AXIAL In Service via APC 3

32 76 H03+.08 SAI 0.1 ODSCC TSP AXIAL In Service via APC 3

32 77 H01+.00 DSI 0.51 ODSCC TSP AXIAL In Service via APC 3

32 78 H01+.03 DSI 0.7 ODSCC TSP AXIAL In Service via APC 3

33 25 H04+.06 DSI 0.95 ODSCC TSP AXIAL In Service via APC 3

33 27 H01+.18 DSI 0.82 ODSCC TSP AXIAL In Service via APC 3

33 31 H03+.09 DSI 0.4 ODSCC TSP AXIAL In Service via APC 3

33 36 H02+.03 DSI 1.12 ODSCC TSP AXIAL In Service via APC 3

33 36 H02+.13 SAI 0.19 ODSCC TSP AXIAL In Service via APC 3

33 36 H02+.15 SAI 0.09 ODSCC TSP AXIAL In Service via APC 3

33 36 H02+.20 SAI 0.11 ODSCC TSP AXIAL In Service via APC 3

33 36 H03+.00 DSI 0.75 ODSCC TSP AXIAL In Service via APC 3

33 40 H01+.03 DSI 1.07 ODSCC TSP AXIAL In Service via APC 3

33 40 H01+.15 SAI 0.28 ODSCC TSP AXIAL In Service via APC 3

33 44 H01+.09 DSI 0.39 ODSCC TSP AXIAL In Service via APC 3

33 45 H02+.17 DSI 0.62 ODSCC TSP AXIAL In Service via APC 3

33 49 H01+.06 DSI 0.57 ODSCC TSP AXIAL In Service via APC 3

33 49 H02+.09 DSI 0.56 ODSCC TSP AXIAL In Service via APC 3

33 49 H02+.04 SAI 0.12 ODSCC TSP AXIAL In Service via APC 3

33 49 H03+.12 DSI 0.64 ODSCC TSP AXIAL In Service via APC 3

33 67 H04-.03 DSI 0.69 ODSCC TSP AXIAL In Service via APC 3

33 70 H02-.03 DSI 0.7 ODSCC TSP AXIAL In Service via APC 3

34 19 H02+.03 DSI 0.84 ODSCC TSP AXIAL In Service via APC 3

34 19 H03+.03 DSI 0.63 ODSCC TSP AXIAL In Service via APC 3

34 22 H01+.03 DSI 1.77 ODSCC TSP AXIAL In Service via APC 3

34 22 H01+.19 SAI 0.3 ODSCC TSP AXIAL In Service via APC 3

34 22 H01+.21 SAI 0.08 ODSCC TSP AXIAL In Service via APC 3

34 22 H01+.23 SAI 0.19 ODSCC TSP AXIAL In Service via APC 3

34 22 H01+.24 SAI 0.25 ODSCC TSP AXIAL In Service via APC 3

34 22 H01+.26 SAI 0.2 ODSCC TSP AXIAL In Service via APC 3

34 25 H01+.00 DSI 1.44 ODSCC TSP AXIAL In Service via APC 3

34 25 H01+.12 SAI 0.25 ODSCC TSP AXIAL In Service via APC 3

34 25 H01+.34 SAI 0.32 ODSCC TSP AXIAL In Service via APC 3

34 25 H03+.17 DSI 0.48 ODSCC TSP AXIAL In Service via APC 3

34 25 H04+.06 DSI 0.61 ODSCC TSP AXIAL In Service via APC 3

34 26 H01+.08 DSI 2.15 ODSCC TSP AXIAL PLUGGED 3

34 26 H01+.20 SAI 0.8 ODSCC TSP AXIAL PLUGGED 3

34 26 H01+.28 SAI 0.17 ODSCC TSP AXIAL PLUGGED 3

34 26 H01+.29 SAI 0.13 ODSCC TSP AXIAL PLUGGED 3

34 27 H03+.03 DSI 0.94 ODSCC TSP AXIAL In Service via APC 3

34 28 H04+.03 DSI 0.4 ODSCC TSP AXIAL In Service via APC 3

34 29 H01+.00 DSI 0.61 ODSCC TSP AXIAL In Service via APC 3

34 30 H01+.06 DSI 2.04 ODSCC TSP AXIAL PLUGGED 3

34 30 H01+.32 SAI 0.13 ODSCC TSP AXIAL PLUGGED 3

34 36 H03+.06 DSI 0.67 ODSCC TSP AXIAL In Service via APC 3

34 51 H02+.06 DSI 0.83 ODSCC TSP AXIAL In Service via APC 3

34 60 H04-.06 DSI 0.42 ODSCC TSP AXIAL In Service via APC 3

34 61 H01+.15 DSI 0.66 ODSCC TSP AXIAL In Service via APC 3

34 61 H03-.03 DSI 0.66 ODSCC TSP AXIAL In Service via APC 3

34 61 H04-.09 DSI 0.48 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 48 of 88 3

34 61 H04+.30 SAI 0.14 ODSCC TSP AXIAL In Service via APC 3

34 72 H01-.06 DSI 0.2 ODSCC TSP AXIAL In Service via APC 3

34 72 H02+.00 DSI 1.32 ODSCC TSP AXIAL In Service via APC 3

34 72 H02+.12 SAI 0.2 ODSCC TSP AXIAL In Service via APC 3

34 72 H02+.22 SAI 0.52 ODSCC TSP AXIAL In Service via APC 3

35 21 H01+.12 DSI 1.35 ODSCC TSP AXIAL In Service via APC 3

35 21 H01+.16 SAI 0.36 ODSCC TSP AXIAL In Service via APC 3

35 21 H01+.24 SAI 0.5 ODSCC TSP AXIAL In Service via APC 3

35 23 H01+.12 DSI 0.44 ODSCC TSP AXIAL In Service via APC 3

35 24 H03+.08 DSI 0.31 ODSCC TSP AXIAL In Service via APC 3

35 27 H01+.09 DSI 0.47 ODSCC TSP AXIAL In Service via APC 3

35 44 H03+.12 DSI 0.68 ODSCC TSP AXIAL In Service via APC 3

35 47 H02+.03 DSI 0.94 ODSCC TSP AXIAL In Service via APC 3

35 47 H03+.11 DSI 0.71 ODSCC TSP AXIAL In Service via APC 3

35 47 H04+.14 DSI 0.3 ODSCC TSP AXIAL In Service via APC 3

35 55 H02-.09 DSI 0.76 ODSCC TSP AXIAL In Service via APC 3

35 58 H02+.06 DSI 1.15 ODSCC TSP AXIAL In Service via APC 3

35 58 H02+.02 SAI 0.17 ODSCC TSP AXIAL In Service via APC 3

35 58 H02+.25 SAI 0.21 ODSCC TSP AXIAL In Service via APC 3

35 58 H05-.18 DSI 0.43 ODSCC TSP AXIAL In Service via APC 3

36 21 C02-.21 DSI 0.41 ODSCC TSP AXIAL In Service via APC 3

36 24 H01+.03 DSI 1.41 ODSCC TSP AXIAL In Service via APC 3

36 24 H01+.18 SAI 0.21 ODSCC TSP AXIAL In Service via APC 3

36 24 H01+.21 SAI 0.15 ODSCC TSP AXIAL In Service via APC 3

36 25 H02+.03 DSI 1.36 ODSCC TSP AXIAL In Service via APC 3

36 31 H03+.06 DSI 0.94 ODSCC TSP AXIAL In Service via APC 3

36 31 H05+.12 DSI 1.12 ODSCC TSP AXIAL In Service via APC 3

36 33 H03+.06 DSI 1.2 ODSCC TSP AXIAL In Service via APC 3

36 38 H02+.06 DSI 0.88 ODSCC TSP AXIAL In Service via APC 3

36 40 H04+.06 DSI 0.7 ODSCC TSP AXIAL In Service via APC 3

36 42 H04+.09 DSI 0.97 ODSCC TSP AXIAL In Service via APC 3

36 48 H02+.11 DSI 0.32 ODSCC TSP AXIAL In Service via APC 3

36 53 H03+.03 DSI 1.07 ODSCC TSP AXIAL In Service via APC 3

36 68 H02+.00 DSI 0.21 ODSCC TSP AXIAL In Service via APC 3

37 21 C01+.23 DSI 0.25 ODSCC TSP AXIAL In Service via APC 3

37 23 H01-.06 DSI 0.58 ODSCC TSP AXIAL In Service via APC 3

37 26 H02+.03 DSI 1.05 ODSCC TSP AXIAL In Service via APC 3

37 26 H02+.12 SAI 0.1 ODSCC TSP AXIAL In Service via APC 3

37 27 H02+.06 DSI 0.56 ODSCC TSP AXIAL In Service via APC 3

37 28 H02+.00 DSI 1.27 ODSCC TSP AXIAL In Service via APC 3

37 28 H02+.18 SAI 0.13 ODSCC TSP AXIAL In Service via APC 3

37 31 H01+.09 DSI 1.04 ODSCC TSP AXIAL In Service via APC 3

37 31 H01-.18 SAI 0.12 ODSCC TSP AXIAL In Service via APC 3

37 31 H03+.03 DSI 0.89 ODSCC TSP AXIAL In Service via APC 3

37 42 H03+.09 DSI 0.93 ODSCC TSP AXIAL In Service via APC 3

37 66 H04-.09 DSI 0.49 ODSCC TSP AXIAL In Service via APC 3

37 67 H02-.09 DSI 0.56 ODSCC TSP AXIAL In Service via APC 3

37 68 H02-.03 DSI 0.44 ODSCC TSP AXIAL In Service via APC 3

38 22 H01+.16 DSI 2.27 ODSCC TSP AXIAL PLUGGED 3

38 22 H01+.11 SAI 0.09 ODSCC TSP AXIAL PLUGGED 3

38 22 H01+.21 SAI 0.16 ODSCC TSP AXIAL PLUGGED 3

38 22 H01+.29 SAI 0.33 ODSCC TSP AXIAL PLUGGED 3

38 22 H01+.34 SAI 0.15 ODSCC TSP AXIAL PLUGGED 3

38 22 H01+.37 SAI 0.59 ODSCC TSP AXIAL PLUGGED 3

38 25 H01+.20 DSI 0.49 ODSCC TSP AXIAL In Service via APC 3

38 25 H03+.15 DSI 0.9 ODSCC TSP AXIAL In Service via APC 3

38 29 H01+.09 DSI 0.8 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 49 of 88 3

38 29 H02+.06 DSI 0.41 ODSCC TSP AXIAL In Service via APC 3

38 32 H06+.06 DSI 0.7 ODSCC TSP AXIAL In Service via APC 3

38 36 H02+.03 DSI 0.68 ODSCC TSP AXIAL In Service via APC 3

38 40 H03+.06 DSI 1.19 ODSCC TSP AXIAL In Service via APC 3

38 40 H03+.32 SAI 0.26 ODSCC TSP AXIAL In Service via APC 3

38 42 H03+.06 DSI 0.9 ODSCC TSP AXIAL In Service via APC 3

38 44 H03+.12 DSI 0.87 ODSCC TSP AXIAL In Service via APC 3

38 46 H02+.09 DSI 0.57 ODSCC TSP AXIAL In Service via APC 3

38 46 H02-.01 SAI 0.09 ODSCC TSP AXIAL In Service via APC 3

38 46 H02+.05 SAI 0.11 ODSCC TSP AXIAL In Service via APC 3

38 58 H02-.06 DSI 1.71 ODSCC TSP AXIAL In Service via APC 3

38 58 H03+.03 DSI 0.58 ODSCC TSP AXIAL In Service via APC 3

38 58 H04+.00 DSI 0.25 ODSCC TSP AXIAL In Service via APC 3

38 58 H05+.00 DSI 0.45 ODSCC TSP AXIAL In Service via APC 3

39 26 H01-.06 DSI 1.02 ODSCC TSP AXIAL In Service via APC 3

39 26 H01+.33 SAI 0.45 ODSCC TSP AXIAL In Service via APC 3

39 26 H01+.34 SAI 0.2 ODSCC TSP AXIAL In Service via APC 3

39 26 H02-.03 DSI 1.17 ODSCC TSP AXIAL In Service via APC 3

39 26 H02+.15 SAI 0.15 ODSCC TSP AXIAL In Service via APC 3

39 26 H03+.09 DSI 0.89 ODSCC TSP AXIAL In Service via APC 3

39 48 H02+.14 DSI 0.55 ODSCC TSP AXIAL In Service via APC 3

39 68 H04+.00 DSI 0.41 ODSCC TSP AXIAL In Service via APC 3

39 71 H02-.03 DSI 0.86 ODSCC TSP AXIAL In Service via APC 3

40 24 H02+.00 DSI 1.03 ODSCC TSP AXIAL In Service via APC 3

40 24 H02+.33 SAI 0.26 ODSCC TSP AXIAL In Service via APC 3

40 24 H03+.06 DSI 0.51 ODSCC TSP AXIAL In Service via APC 3

40 25 H01+.06 DSI 0.73 ODSCC TSP AXIAL In Service via APC 3

40 25 H02+.06 DSI 1.19 ODSCC TSP AXIAL In Service via APC 3

40 25 H02+.26 SAI 0.12 ODSCC TSP AXIAL In Service via APC 3

40 25 H03+.03 DSI 0.79 ODSCC TSP AXIAL In Service via APC 3

40 41 H03+.06 DSI 0.42 ODSCC TSP AXIAL In Service via APC 3

40 43 H02-.17 DSI 0.56 ODSCC TSP AXIAL In Service via APC 3

40 62 H03-.03 DSI 0.4 ODSCC TSP AXIAL In Service via APC 3

40 67 H02-.06 DSI 0.46 ODSCC TSP AXIAL In Service via APC 3

40 69 H02-.12 DSI 0.46 ODSCC TSP AXIAL In Service via APC 3

41 30 H01+.06 DSI 0.86 ODSCC TSP AXIAL In Service via APC 3

41 30 H03+.06 DSI 0.52 ODSCC TSP AXIAL In Service via APC 3

41 33 H02+.06 DSI 0.33 ODSCC TSP AXIAL In Service via APC 3

41 36 H04+.06 DSI 0.51 ODSCC TSP AXIAL In Service via APC 3

41 39 H02+.06 DSI 0.86 ODSCC TSP AXIAL In Service via APC 3

41 68 H02+.00 DSI 0.55 ODSCC TSP AXIAL In Service via APC 3

42 33 H01+.03 DSI 0.85 ODSCC TSP AXIAL In Service via APC 3

42 43 H04+.12 DSI 0.64 ODSCC TSP AXIAL In Service via APC 3

42 53 H07-.14 DSI 1.53 ODSCC TSP AXIAL PLUGGED 3

42 53 H07+.01 SAI 0.11 ODSCC TSP AXIAL PLUGGED 3

42 63 H01+.00 DSI 0.36 ODSCC TSP AXIAL In Service via APC 3

43 36 H01+.12 DSI 1.33 ODSCC TSP AXIAL In Service via APC 3

43 36 H01+.18 SAI 0.26 ODSCC TSP AXIAL In Service via APC 3

43 36 H01+.27 SAI 0.09 ODSCC TSP AXIAL In Service via APC 3

43 36 H01+.32 SAI 0.17 ODSCC TSP AXIAL In Service via APC 3

43 44 H04+.12 DSI 0.65 ODSCC TSP AXIAL In Service via APC 3

43 47 H05+.09 DSI 0.6 ODSCC TSP AXIAL In Service via APC 3

43 50 H04+.11 DSI 0.87 ODSCC TSP AXIAL In Service via APC 3

43 59 H01-.06 DSI 0.74 ODSCC TSP AXIAL In Service via APC 3

44 33 H01+.09 DSI 1.32 ODSCC TSP AXIAL In Service via APC 3

44 33 H01+.30 SAI 0.13 ODSCC TSP AXIAL In Service via APC 3

44 33 H01+.32 SAI 0.23 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 50 of 88 3

44 52 H02+.08 DSI 1.01 ODSCC TSP AXIAL In Service via APC 3

44 52 H02+.10 SAI 0.25 ODSCC TSP AXIAL In Service via APC 3

44 52 H02+.13 SAI 0.14 ODSCC TSP AXIAL In Service via APC 3

44 52 H02+.31 SAI 0.18 ODSCC TSP AXIAL In Service via APC 3

44 58 H01+.03 DSI 1.46 ODSCC TSP AXIAL In Service via APC 3

44 58 H01+.09 SAI 0.17 ODSCC TSP AXIAL In Service via APC 3

44 58 H01+.11 SAI 0.16 ODSCC TSP AXIAL In Service via APC 3

44 58 H01+.14 SAI 0.28 ODSCC TSP AXIAL In Service via APC 3

44 58 H02-.09 DSI 0.43 ODSCC TSP AXIAL In Service via APC 3

44 58 H02+.23 SAI 0.17 ODSCC TSP AXIAL In Service via APC 3

44 58 H03-.06 DSI 0.19 ODSCC TSP AXIAL In Service via APC 3

44 58 H03-.07 SAI 0.1 ODSCC TSP AXIAL In Service via APC 3

44 58 H03+.07 SAI 0.13 ODSCC TSP AXIAL In Service via APC 3

44 59 H01+.09 DSI 1.03 ODSCC TSP AXIAL In Service via APC 3

44 59 H01+.35 SAI 0.15 ODSCC TSP AXIAL In Service via APC 3

44 59 H02-.03 DSI 1.91 ODSCC TSP AXIAL In Service via APC 3

44 59 H02+.19 SAI 0.07 ODSCC TSP AXIAL In Service via APC 3

45 39 C04-.09 DSI 0.72 ODSCC TSP AXIAL In Service via APC 3

45 42 H02+.03 DSI 0.67 ODSCC TSP AXIAL In Service via APC 3

45 53 C03-.06 DSI 0.25 ODSCC TSP AXIAL In Service via APC 3

46 52 H01+.11 DSI 0.75 ODSCC TSP AXIAL In Service via APC 3

46 52 H02+.17 DSI 0.35 ODSCC TSP AXIAL In Service via APC 3

46 52 H03+.09 DSI 0.54 ODSCC TSP AXIAL In Service via APC 4

1 82 H01+.17 DSI 0.85 ODSCC TSP AXIAL In Service via APC 4

1 85 H01+.20 DSI 1.33 ODSCC TSP AXIAL In Service via APC 4

2 9

C04+.00 DSI 0.29 ODSCC TSP AXIAL In Service via APC 4

2 9

H03+.03 DSI 0.93 ODSCC TSP AXIAL In Service via APC 4

2 14 H03-.11 DSI 0.51 ODSCC TSP AXIAL In Service via APC 4

2 15 H02+.00 DSI 0.73 ODSCC TSP AXIAL In Service via APC 4

2 15 H03+.03 DSI 0.91 ODSCC TSP AXIAL In Service via APC 4

2 25 H01-.06 DSI 0.83 ODSCC TSP AXIAL In Service via APC 4

2 38 H02+.14 DSI 0.61 ODSCC TSP AXIAL In Service via APC 4

2 38 H03+.06 DSI 0.92 ODSCC TSP AXIAL In Service via APC 4

2 47 H01+.00 DSI 0.67 ODSCC TSP AXIAL In Service via APC 4

2 53 H01+.06 DSI 0.86 ODSCC TSP AXIAL In Service via APC 4

2 53 H02+.15 DSI 1.05 ODSCC TSP AXIAL In Service via APC 4

2 53 H02+.21 SAI 0.23 ODSCC TSP AXIAL In Service via APC 4

2 53 H02+.27 SAI 0.25 ODSCC TSP AXIAL In Service via APC 4

2 54 H02-.03 DSI 0.45 ODSCC TSP AXIAL In Service via APC 4

2 54 H05-.09 DSI 0.48 ODSCC TSP AXIAL In Service via APC 4

2 55 H01+.03 DSI 1.26 ODSCC TSP AXIAL In Service via APC 4

2 55 H01+.14 SAI 0.29 ODSCC TSP AXIAL In Service via APC 4

2 55 H01+.25 SAI 0.39 ODSCC TSP AXIAL In Service via APC 4

2 56 H03+.15 DSI 0.57 ODSCC TSP AXIAL In Service via APC 4

2 57 H01+.12 DSI 0.56 ODSCC TSP AXIAL In Service via APC 4

2 57 H03+.26 DSI 0.67 ODSCC TSP AXIAL In Service via APC 4

2 58 H01+.00 DSI 0.43 ODSCC TSP AXIAL In Service via APC 4

2 64 H02+.03 DSI 0.8 ODSCC TSP AXIAL In Service via APC 4

2 67 H01+.06 DSI 1.48 ODSCC TSP AXIAL In Service via APC 4

2 67 H01+.20 SAI 0.4 ODSCC TSP AXIAL In Service via APC 4

2 67 H01+.30 SAI 0.51 ODSCC TSP AXIAL In Service via APC 4

2 72 H02+.00 DSI 0.98 ODSCC TSP AXIAL In Service via APC 4

2 74 H01-.15 DSI 0.68 ODSCC TSP AXIAL In Service via APC 4

2 74 H02-.15 DSI 1.17 ODSCC TSP AXIAL In Service via APC 4

2 74 H02+.04 SAI 0.27 ODSCC TSP AXIAL In Service via APC 4

2 74 H02+.11 SAI 0.44 ODSCC TSP AXIAL In Service via APC 4

2 75 H01-.03 DSI 0.52 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 51 of 88 4

2 76 H01+.09 DSI 1.63 ODSCC TSP AXIAL In Service via APC 4

2 76 H01+.14 SAI 0.62 ODSCC TSP AXIAL In Service via APC 4

2 76 H01+.27 SAI 0.52 ODSCC TSP AXIAL In Service via APC 4

2 76 H01+.28 SAI 0.48 ODSCC TSP AXIAL In Service via APC 4

2 84 H01+.15 DSI 0.37 ODSCC TSP AXIAL In Service via APC 4

2 84 H02-.03 DSI 0.25 ODSCC TSP AXIAL In Service via APC 4

2 85 H01-.06 DSI 0.46 ODSCC TSP AXIAL In Service via APC 4

2 85 H02+.03 DSI 0.58 ODSCC TSP AXIAL In Service via APC 4

2 86 H02+.00 DSI 0.88 ODSCC TSP AXIAL In Service via APC 4

2 88 H03-.03 DSI 0.72 ODSCC TSP AXIAL In Service via APC 4

2 90 H01-.06 DSI 0.75 ODSCC TSP AXIAL In Service via APC 4

2 92 H01+.00 DSI 0.58 ODSCC TSP AXIAL In Service via APC 4

2 94 H01+.00 DSI 0.52 ODSCC TSP AXIAL In Service via APC 4

3 16 H02+.09 DSI 0.63 ODSCC TSP AXIAL In Service via APC 4

3 16 H04-.17 DSI 0.59 ODSCC TSP AXIAL In Service via APC 4

3 18 H01+.06 DSI 0.58 ODSCC TSP AXIAL In Service via APC 4

3 18 H02-.03 DSI 1.05 ODSCC TSP AXIAL In Service via APC 4

3 18 H02+.00 SAI 0.69 ODSCC TSP AXIAL In Service via APC 4

3 19 H02+.06 DSI 0.35 ODSCC TSP AXIAL In Service via APC 4

3 21 H02+.14 DSI 0.77 ODSCC TSP AXIAL In Service via APC 4

3 22 H02-.09 DSI 0.71 ODSCC TSP AXIAL In Service via APC 4

3 25 H01+.12 DSI 0.88 ODSCC TSP AXIAL In Service via APC 4

3 25 H02-.14 DSI 0.96 ODSCC TSP AXIAL In Service via APC 4

3 25 H03+.06 DSI 0.78 ODSCC TSP AXIAL In Service via APC 4

3 28 H03+.00 DSI 0.99 ODSCC TSP AXIAL In Service via APC 4

3 30 H01+.00 DSI 0.51 ODSCC TSP AXIAL In Service via APC 4

3 34 H02+.00 DSI 0.41 ODSCC TSP AXIAL In Service via APC 4

3 35 C03-.03 DSI 0.39 ODSCC TSP AXIAL In Service via APC 4

3 43 H01+.00 DSI 1.26 ODSCC TSP AXIAL PLUGGED-Preventive 4

3 43 H01+.30 SAI 0.97 ODSCC TSP AXIAL PLUGGED-Preventive 4

3 71 H01-.06 DSI 1.23 ODSCC TSP AXIAL In Service via APC 4

3 71 H01+.20 SAI 0.58 ODSCC TSP AXIAL In Service via APC 4

3 71 H02+.09 DSI 0.41 ODSCC TSP AXIAL In Service via APC 4

3 81 H02+.00 DSI 0.66 ODSCC TSP AXIAL In Service via APC 4

3 87 H01+.00 DSI 0.51 ODSCC TSP AXIAL In Service via APC 4

3 87 H02+.00 DSI 0.96 ODSCC TSP AXIAL In Service via APC 4

3 88 H01+.00 DSI 0.94 ODSCC TSP AXIAL In Service via APC 4

3 88 H02+.00 DSI 0.92 ODSCC TSP AXIAL In Service via APC 4

3 89 H02+.00 DSI 1.06 ODSCC TSP AXIAL In Service via APC 4

3 90 H01-.03 DSI 0.8 ODSCC TSP AXIAL In Service via APC 4

3 90 H02+.00 DSI 0.66 ODSCC TSP AXIAL In Service via APC 4

3 91 H01+.00 DSI 0.93 ODSCC TSP AXIAL In Service via APC 4

3 92 H01+.00 DSI 0.78 ODSCC TSP AXIAL In Service via APC 4

3 93 H02+.00 DSI 1.03 ODSCC TSP AXIAL In Service via APC 4

3 94 H01+.00 DSI 1.05 ODSCC TSP AXIAL In Service via APC 4

4 3

H02+.03 DSI 0.62 ODSCC TSP AXIAL In Service via APC 4

4 8

H03-.03 DSI 0.51 ODSCC TSP AXIAL In Service via APC 4

4 8

H05-.06 DSI 0.62 ODSCC TSP AXIAL In Service via APC 4

4 8

H06-.03 DSI 0.5 ODSCC TSP AXIAL In Service via APC 4

4 12 H02+.06 DSI 0.61 ODSCC TSP AXIAL In Service via APC 4

4 13 H02+.14 DSI 0.69 ODSCC TSP AXIAL In Service via APC 4

4 13 H02+.23 SAI 0.31 ODSCC TSP AXIAL In Service via APC 4

4 13 H03-.17 DSI 0.57 ODSCC TSP AXIAL In Service via APC 4

4 14 H03-.03 DSI 0.29 ODSCC TSP AXIAL In Service via APC 4

4 14 H06-.06 DSI 0.48 ODSCC TSP AXIAL In Service via APC 4

4 18 H01-.11 DSI 0.68 ODSCC TSP AXIAL In Service via APC 4

4 19 H02+.06 DSI 0.66 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 52 of 88 4

4 22 H02+.09 DSI 0.34 ODSCC TSP AXIAL In Service via APC 4

4 23 H01+.14 DSI 1.04 ODSCC TSP AXIAL In Service via APC 4

4 23 H01+.30 SAI 0.26 ODSCC TSP AXIAL In Service via APC 4

4 25 H01+.00 DSI 0.85 ODSCC TSP AXIAL In Service via APC 4

4 27 H01-.03 DSI 0.46 ODSCC TSP AXIAL In Service via APC 4

4 27 H03+.00 DSI 0.59 ODSCC TSP AXIAL In Service via APC 4

4 28 H01+.00 DSI 0.73 ODSCC TSP AXIAL In Service via APC 4

4 28 H04-.03 DSI 0.55 ODSCC TSP AXIAL In Service via APC 4

4 28 H06+.03 DSI 0.36 ODSCC TSP AXIAL In Service via APC 4

4 30 H03+.03 DSI 0.5 ODSCC TSP AXIAL In Service via APC 4

4 40 H01+.00 DSI 1.18 ODSCC TSP AXIAL In Service via APC 4

4 40 H01+.23 SAI 0.66 ODSCC TSP AXIAL In Service via APC 4

4 41 H01-.08 DSI 0.52 ODSCC TSP AXIAL In Service via APC 4

4 47 H02+.00 DSI 0.69 ODSCC TSP AXIAL In Service via APC 4

4 74 H03-.03 DSI 0.89 ODSCC TSP AXIAL In Service via APC 4

4 77 H01+.00 DSI 0.56 ODSCC TSP AXIAL In Service via APC 4

4 78 H01+.03 DSI 0.55 ODSCC TSP AXIAL In Service via APC 4

4 78 H02-.03 DSI 0.42 ODSCC TSP AXIAL In Service via APC 4

4 80 H04+.03 DSI 0.85 ODSCC TSP AXIAL In Service via APC 4

4 82 H01+.06 DSI 1.51 ODSCC TSP AXIAL In Service via APC 4

4 82 H01+.19 SAI 0.26 ODSCC TSP AXIAL In Service via APC 4

4 82 H01+.22 SAI 0.39 ODSCC TSP AXIAL In Service via APC 4

4 82 H02-.03 DSI 0.86 ODSCC TSP AXIAL In Service via APC 4

4 84 H02-.06 DSI 0.66 ODSCC TSP AXIAL In Service via APC 4

4 86 H03+.03 DSI 1.02 ODSCC TSP AXIAL In Service via APC 4

4 86 H03+.09 SAI 0.19 ODSCC TSP AXIAL In Service via APC 4

4 87 H01+.17 DSI 1.16 ODSCC TSP AXIAL In Service via APC 4

4 87 H01+.02 SAI 0.19 ODSCC TSP AXIAL In Service via APC 4

4 87 H01+.21 SAI 0.29 ODSCC TSP AXIAL In Service via APC 4

4 87 H01+.30 SAI 0.2 ODSCC TSP AXIAL In Service via APC 4

4 87 H03-.06 DSI 0.86 ODSCC TSP AXIAL In Service via APC 4

4 87 H05-.03 DSI 0.59 ODSCC TSP AXIAL In Service via APC 4

4 88 H02+.06 DSI 0.96 ODSCC TSP AXIAL In Service via APC 4

4 88 H03-.03 DSI 0.58 ODSCC TSP AXIAL In Service via APC 4

4 89 H03+.06 DSI 1.13 ODSCC TSP AXIAL In Service via APC 4

4 89 H03+.19 SAI 0.22 ODSCC TSP AXIAL In Service via APC 4

4 90 H01+.17 DSI 1.22 ODSCC TSP AXIAL In Service via APC 4

4 90 H01+.14 SAI 0.14 ODSCC TSP AXIAL In Service via APC 4

4 90 H01+.28 SAI 0.11 ODSCC TSP AXIAL In Service via APC 4

4 90 H01+.32 SAI 0.2 ODSCC TSP AXIAL In Service via APC 4

4 90 H02+.00 DSI 1.11 ODSCC TSP AXIAL In Service via APC 4

4 90 H03+.00 DSI 0.79 ODSCC TSP AXIAL In Service via APC 4

4 90 H06+.00 DSI 0.54 ODSCC TSP AXIAL In Service via APC 4

4 91 H01+.06 DSI 0.46 ODSCC TSP AXIAL In Service via APC 4

4 91 H02+.00 DSI 0.87 ODSCC TSP AXIAL In Service via APC 4

4 92 H03+.06 DSI 1.11 ODSCC TSP AXIAL In Service via APC 4

4 92 H03+.25 SAI 0.15 ODSCC TSP AXIAL In Service via APC 4

4 93 H02+.17 DSI 0.78 ODSCC TSP AXIAL In Service via APC 4

4 94 H01-.03 DSI 1.33 ODSCC TSP AXIAL In Service via APC 4

4 94 H01+.17 SAI 0.16 ODSCC TSP AXIAL In Service via APC 4

4 94 H01+.26 SAI 0.13 ODSCC TSP AXIAL In Service via APC 4

5 1

H01-.09 DSI 0.24 ODSCC TSP AXIAL In Service via APC 4

5 1

H02-.03 DSI 0.49 ODSCC TSP AXIAL In Service via APC 4

5 1

H05-.03 DSI 0.49 ODSCC TSP AXIAL In Service via APC 4

5 26 H01-.03 DSI 0.46 ODSCC TSP AXIAL In Service via APC 4

5 28 H01-.03 DSI 1.28 ODSCC TSP AXIAL In Service via APC 4

5 28 H01+.22 SAI 0.23 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 53 of 88 4

5 28 H01+.24 SAI 0.38 ODSCC TSP AXIAL In Service via APC 4

5 28 H02-.20 DSI 0.55 ODSCC TSP AXIAL In Service via APC 4

5 29 H01+.06 DSI 0.48 ODSCC TSP AXIAL In Service via APC 4

5 29 H02+.03 DSI 0.48 ODSCC TSP AXIAL In Service via APC 4

5 29 H04-.14 DSI 0.36 ODSCC TSP AXIAL In Service via APC 4

5 30 H01-.03 DSI 1.15 ODSCC TSP AXIAL In Service via APC 4

5 30 H01-.01 SAI 0.21 ODSCC TSP AXIAL In Service via APC 4

5 30 H01+.20 SAI 0.29 ODSCC TSP AXIAL In Service via APC 4

5 30 H01+.21 SAI 0.25 ODSCC TSP AXIAL In Service via APC 4

5 32 H03+.00 DSI 0.63 ODSCC TSP AXIAL In Service via APC 4

5 33 H01+.09 DSI 0.9 ODSCC TSP AXIAL In Service via APC 4

5 34 H01-.08 DSI 1.33 ODSCC TSP AXIAL In Service via APC 4

5 34 H01+.18 SAI 0.85 ODSCC TSP AXIAL In Service via APC 4

5 35 H01-.09 DSI 1.14 ODSCC TSP AXIAL In Service via APC 4

5 35 H01+.21 SAI 0.35 ODSCC TSP AXIAL In Service via APC 4

5 35 H01+.27 SAI 0.46 ODSCC TSP AXIAL In Service via APC 4

5 36 H01+.06 DSI 0.49 ODSCC TSP AXIAL In Service via APC 4

5 37 H01-.03 DSI 0.58 ODSCC TSP AXIAL In Service via APC 4

5 37 H02+.00 DSI 0.35 ODSCC TSP AXIAL In Service via APC 4

5 38 H01+.00 DSI 1.21 ODSCC TSP AXIAL In Service via APC 4

5 38 H01+.10 SAI 0.22 ODSCC TSP AXIAL In Service via APC 4

5 38 H01+.23 SAI 0.18 ODSCC TSP AXIAL In Service via APC 4

5 39 H01+.03 DSI 1.37 ODSCC TSP AXIAL In Service via APC 4

5 39 H01+.26 SAI 0.16 ODSCC TSP AXIAL In Service via APC 4

5 39 H01+.36 SAI 0.3 ODSCC TSP AXIAL In Service via APC 4

5 41 H01+.06 DSI 0.58 ODSCC TSP AXIAL In Service via APC 4

5 42 H01+.00 DSI 1.44 ODSCC TSP AXIAL In Service via APC 4

5 42 H01+.10 SAI 0.24 ODSCC TSP AXIAL In Service via APC 4

5 42 H01+.16 SAI 0.08 ODSCC TSP AXIAL In Service via APC 4

5 42 H01+.17 SAI 0.2 ODSCC TSP AXIAL In Service via APC 4

5 43 H01-.11 DSI 0.83 ODSCC TSP AXIAL In Service via APC 4

5 43 H02+.00 DSI 1.06 ODSCC TSP AXIAL In Service via APC 4

5 43 H02+.24 SAI 0.24 ODSCC TSP AXIAL In Service via APC 4

5 43 H03+.00 DSI 0.71 ODSCC TSP AXIAL In Service via APC 4

5 44 H01-.09 DSI 0.76 ODSCC TSP AXIAL In Service via APC 4

5 46 H01+.03 DSI 0.49 ODSCC TSP AXIAL In Service via APC 4

5 46 H03+.09 DSI 0.37 ODSCC TSP AXIAL In Service via APC 4

5 47 H01-.03 DSI 0.79 ODSCC TSP AXIAL In Service via APC 4

5 53 H01+.00 DSI 0.73 ODSCC TSP AXIAL In Service via APC 4

5 63 H01+.03 DSI 0.72 ODSCC TSP AXIAL In Service via APC 4

5 69 H01+.00 DSI 0.49 ODSCC TSP AXIAL In Service via APC 4

5 71 H01+.03 DSI 1.31 ODSCC TSP AXIAL In Service via APC 4

5 71 H01+.06 SAI 0.18 ODSCC TSP AXIAL In Service via APC 4

5 71 H01+.19 SAI 0.13 ODSCC TSP AXIAL In Service via APC 4

5 71 H01+.26 SAI 0.19 ODSCC TSP AXIAL In Service via APC 4

5 72 H01+.06 DSI 0.73 ODSCC TSP AXIAL In Service via APC 4

5 73 H01+.06 DSI 0.71 ODSCC TSP AXIAL In Service via APC 4

5 74 H01-.14 DSI 0.83 ODSCC TSP AXIAL In Service via APC 4

5 75 H03+.03 DSI 0.51 ODSCC TSP AXIAL In Service via APC 4

5 76 H01-.11 DSI 0.64 ODSCC TSP AXIAL In Service via APC 4

5 77 H01+.00 DSI 0.77 ODSCC TSP AXIAL In Service via APC 4

5 78 H02-.09 DSI 0.88 ODSCC TSP AXIAL In Service via APC 4

5 79 H01+.06 DSI 0.71 ODSCC TSP AXIAL In Service via APC 4

5 80 H01+.03 DSI 1.43 ODSCC TSP AXIAL In Service via APC 4

5 80 H01+.03 SAI 0.21 ODSCC TSP AXIAL In Service via APC 4

5 80 H01+.23 SAI 0.13 ODSCC TSP AXIAL In Service via APC 4

5 80 H01+.29 SAI 0.16 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 54 of 88 4

5 82 H01+.17 DSI 0.77 ODSCC TSP AXIAL In Service via APC 4

5 83 H01+.06 DSI 1.05 ODSCC TSP AXIAL In Service via APC 4

5 83 H01+.14 SAI 0.35 ODSCC TSP AXIAL In Service via APC 4

5 83 H01+.23 SAI 0.22 ODSCC TSP AXIAL In Service via APC 4

5 87 H04-.11 DSI 0.24 ODSCC TSP AXIAL In Service via APC 4

5 88 H02+.00 DSI 1.26 ODSCC TSP AXIAL In Service via APC 4

5 89 H01-.11 DSI 1.39 ODSCC TSP AXIAL In Service via APC 4

5 89 H01+.10 SAI 0.33 ODSCC TSP AXIAL In Service via APC 4

5 89 H01+.26 SAI 0.18 ODSCC TSP AXIAL In Service via APC 4

5 91 H01+.00 DSI 1.24 ODSCC TSP AXIAL In Service via APC 4

5 91 H01+.10 SAI 0.26 ODSCC TSP AXIAL In Service via APC 4

5 91 H03+.03 DSI 0.64 ODSCC TSP AXIAL In Service via APC 4

5 92 H01+.06 DSI 0.92 ODSCC TSP AXIAL In Service via APC 4

5 92 H03+.06 DSI 0.56 ODSCC TSP AXIAL In Service via APC 4

5 93 H01+.09 DSI 1.03 ODSCC TSP AXIAL In Service via APC 4

5 93 H01+.26 SAI 0.43 ODSCC TSP AXIAL In Service via APC 4

5 93 H01+.34 SAI 0.35 ODSCC TSP AXIAL In Service via APC 4

6 2

H02-.03 DSI 0.69 ODSCC TSP AXIAL In Service via APC 4

6 8

H01+.00 DSI 0.35 ODSCC TSP AXIAL In Service via APC 4

6 18 H03-.06 DSI 1.12 ODSCC TSP AXIAL PLUGGED-Preventive 4

6 18 H03+.26 SAI 0.85 ODSCC TSP AXIAL PLUGGED-Preventive 4

6 23 H02+.00 DSI 1.01 ODSCC TSP AXIAL In Service via APC 4

6 23 H02+.15 SAI 0.07 ODSCC TSP AXIAL In Service via APC 4

6 23 H02+.32 SAI 0.15 ODSCC TSP AXIAL In Service via APC 4

6 24 H01+.00 DSI 0.56 ODSCC TSP AXIAL In Service via APC 4

6 25 H02-.12 DSI 0.55 ODSCC TSP AXIAL In Service via APC 4

6 28 H01-.03 DSI 0.88 ODSCC TSP AXIAL In Service via APC 4

6 30 H01+.00 DSI 0.5 ODSCC TSP AXIAL In Service via APC 4

6 32 H02+.09 DSI 0.31 ODSCC TSP AXIAL In Service via APC 4

6 38 H02+.00 DSI 0.61 ODSCC TSP AXIAL In Service via APC 4

6 39 H02+.03 DSI 0.85 ODSCC TSP AXIAL In Service via APC 4

6 42 H01-.03 DSI 0.88 ODSCC TSP AXIAL In Service via APC 4

6 45 H01+.06 DSI 0.81 ODSCC TSP AXIAL In Service via APC 4

6 47 H01-.03 DSI 0.41 ODSCC TSP AXIAL In Service via APC 4

6 66 H01+.00 DSI 0.89 ODSCC TSP AXIAL In Service via APC 4

6 68 H01-.03 DSI 0.72 ODSCC TSP AXIAL In Service via APC 4

6 69 H01-.09 DSI 0.33 ODSCC TSP AXIAL In Service via APC 4

6 72 H01-.06 DSI 0.87 ODSCC TSP AXIAL In Service via APC 4

6 73 H01+.00 DSI 0.65 ODSCC TSP AXIAL In Service via APC 4

6 74 H01+.06 DSI 1.09 ODSCC TSP AXIAL In Service via APC 4

6 74 H01+.20 SAI 0.57 ODSCC TSP AXIAL In Service via APC 4

6 75 H01+.09 DSI 1

ODSCC TSP AXIAL In Service via APC 4

6 75 H01+.23 SAI 0.17 ODSCC TSP AXIAL In Service via APC 4

6 76 H01-.03 DSI 0.79 ODSCC TSP AXIAL In Service via APC 4

6 78 H01+.03 DSI 0.77 ODSCC TSP AXIAL In Service via APC 4

6 80 H01+.00 DSI 1.12 ODSCC TSP AXIAL In Service via APC 4

6 80 H01+.18 SAI 0.15 ODSCC TSP AXIAL In Service via APC 4

6 81 H02+.00 DSI 0.86 ODSCC TSP AXIAL In Service via APC 4

6 84 H01+.14 DSI 0.51 ODSCC TSP AXIAL In Service via APC 4

6 87 H02+.00 DSI 0.95 ODSCC TSP AXIAL In Service via APC 4

6 87 H03+.00 DSI 0.52 ODSCC TSP AXIAL In Service via APC 4

6 88 H01+.03 DSI 1.19 ODSCC TSP AXIAL In Service via APC 4

6 88 H01+.21 SAI 0.17 ODSCC TSP AXIAL In Service via APC 4

6 88 H02-.03 DSI 0.68 ODSCC TSP AXIAL In Service via APC 4

6 90 H01+.14 DSI 0.97 ODSCC TSP AXIAL In Service via APC 4

6 90 H02+.00 DSI 0.7 ODSCC TSP AXIAL In Service via APC 4

6 90 H03-.03 DSI 0.78 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 55 of 88 4

6 90 H04+.00 DSI 0.84 ODSCC TSP AXIAL In Service via APC 4

6 91 H01-.03 DSI 1.09 ODSCC TSP AXIAL In Service via APC 4

6 91 H01+.30 SAI 0.55 ODSCC TSP AXIAL In Service via APC 4

6 91 H02-.06 DSI 0.89 ODSCC TSP AXIAL In Service via APC 4

6 92 H01+.03 DSI 0.58 ODSCC TSP AXIAL In Service via APC 4

6 94 H03-.03 DSI 0.55 ODSCC TSP AXIAL In Service via APC 4

7 18 H02-.03 DSI 0.81 ODSCC TSP AXIAL In Service via APC 4

7 22 H02-.03 DSI 0.92 ODSCC TSP AXIAL In Service via APC 4

7 33 H03+.00 DSI 0.27 ODSCC TSP AXIAL In Service via APC 4

7 46 H01+.00 DSI 0.8 ODSCC TSP AXIAL In Service via APC 4

7 47 H01+.06 DSI 0.48 ODSCC TSP AXIAL In Service via APC 4

7 48 H01-.03 DSI 1.85 ODSCC TSP AXIAL In Service via APC 4

7 48 H01+.27 SAI 0.32 ODSCC TSP AXIAL In Service via APC 4

7 48 H01+.28 SAI 0.66 ODSCC TSP AXIAL In Service via APC 4

7 54 H01+.00 DSI 1.2 ODSCC TSP AXIAL In Service via APC 4

7 55 H01+.00 DSI 1.59 ODSCC TSP AXIAL In Service via APC 4

7 55 H01+.15 SAI 0.61 ODSCC TSP AXIAL In Service via APC 4

7 55 H01+.28 SAI 0.2 ODSCC TSP AXIAL In Service via APC 4

7 55 H01+.33 SAI 0.6 ODSCC TSP AXIAL In Service via APC 4

7 56 H01-.11 DSI 0.82 ODSCC TSP AXIAL In Service via APC 4

7 57 H01+.00 DSI 0.79 ODSCC TSP AXIAL In Service via APC 4

7 58 H01-.09 DSI 1.23 ODSCC TSP AXIAL In Service via APC 4

7 58 H01+.18 SAI 0.67 ODSCC TSP AXIAL In Service via APC 4

7 59 H01+.03 DSI 1.1 ODSCC TSP AXIAL In Service via APC 4

7 59 H01+.15 SAI 0.12 ODSCC TSP AXIAL In Service via APC 4

7 59 H01+.23 SAI 0.29 ODSCC TSP AXIAL In Service via APC 4

7 61 H03-.06 DSI 0.7 ODSCC TSP AXIAL In Service via APC 4

7 61 H03+.15 SAI 0.26 ODSCC TSP AXIAL In Service via APC 4

7 62 H01-.06 DSI 0.37 ODSCC TSP AXIAL In Service via APC 4

7 64 H01+.03 DSI 0.51 ODSCC TSP AXIAL In Service via APC 4

7 68 H01+.00 DSI 0.48 ODSCC TSP AXIAL In Service via APC 4

8 2

H02+.00 DSI 1.05 ODSCC TSP AXIAL In Service via APC 4

8 2

H02+.19 SAI 0.2 ODSCC TSP AXIAL In Service via APC 4

8 2

H02+.22 SAI 0.16 ODSCC TSP AXIAL In Service via APC 4

8 2

H02+.33 SAI 0.16 ODSCC TSP AXIAL In Service via APC 4

8 4

H02-.03 DSI 0.55 ODSCC TSP AXIAL In Service via APC 4

8 4

H02+.07 SAI 0.13 ODSCC TSP AXIAL In Service via APC 4

8 4

H02+.13 SAI 0.1 ODSCC TSP AXIAL In Service via APC 4

8 4

H02+.23 SAI 0.07 ODSCC TSP AXIAL In Service via APC 4

8 5

H02+.12 DSI 0.7 ODSCC TSP AXIAL In Service via APC 4

8 8

H02-.09 DSI 0.39 ODSCC TSP AXIAL In Service via APC 4

8 12 H01+.14 DSI 0.59 ODSCC TSP AXIAL In Service via APC 4

8 12 H03+.00 DSI 0.8 ODSCC TSP AXIAL In Service via APC 4

8 13 H01+.00 DSI 0.52 ODSCC TSP AXIAL In Service via APC 4

8 13 H05-.09 DSI 0.4 ODSCC TSP AXIAL In Service via APC 4

8 16 H03+.00 DSI 0.36 ODSCC TSP AXIAL In Service via APC 4

8 17 H02+.17 DSI 0.99 ODSCC TSP AXIAL In Service via APC 4

8 19 H01-.03 DSI 0.77 ODSCC TSP AXIAL In Service via APC 4

8 21 H02-.14 DSI 0.81 ODSCC TSP AXIAL In Service via APC 4

8 25 H01+.09 DSI 0.54 ODSCC TSP AXIAL In Service via APC 4

8 25 H04-.06 DSI 0.45 ODSCC TSP AXIAL In Service via APC 4

8 25 H04+.05 SAI 0.13 ODSCC TSP AXIAL In Service via APC 4

8 27 H01-.15 DSI 0.7 ODSCC TSP AXIAL In Service via APC 4

8 27 H02+.18 DSI 0.51 ODSCC TSP AXIAL In Service via APC 4

8 27 H03-.24 DSI 0.82 ODSCC TSP AXIAL In Service via APC 4

8 28 H01-.03 DSI 0.83 ODSCC TSP AXIAL In Service via APC 4

8 29 H01+.06 DSI 0.84 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 56 of 88 4

8 29 H02-.03 DSI 0.56 ODSCC TSP AXIAL In Service via APC 4

8 30 H01+.00 DSI 0.6 ODSCC TSP AXIAL In Service via APC 4

8 31 H01+.09 DSI 0.95 ODSCC TSP AXIAL In Service via APC 4

8 31 H03+.03 DSI 0.68 ODSCC TSP AXIAL In Service via APC 4

8 33 H01+.00 DSI 0.57 ODSCC TSP AXIAL In Service via APC 4

8 34 H01+.09 DSI 1.66 ODSCC TSP AXIAL In Service via APC 4

8 34 H01+.05 SAI 0.32 ODSCC TSP AXIAL In Service via APC 4

8 34 H01+.29 SAI 0.56 ODSCC TSP AXIAL In Service via APC 4

8 34 H01+.30 SAI 0.34 ODSCC TSP AXIAL In Service via APC 4

8 35 H01-.08 DSI 0.62 ODSCC TSP AXIAL In Service via APC 4

8 35 H04-.14 DSI 0.33 ODSCC TSP AXIAL In Service via APC 4

8 36 H01-.23 DSI 0.76 ODSCC TSP AXIAL In Service via APC 4

8 36 H02-.03 DSI 0.32 ODSCC TSP AXIAL In Service via APC 4

8 37 H01+.06 DSI 2.06 ODSCC TSP AXIAL PLUGGED 4

8 37 H01+.22 SAI 0.22 ODSCC TSP AXIAL PLUGGED 4

8 37 H01+.27 SAI 0.13 ODSCC TSP AXIAL PLUGGED 4

8 37 H01+.33 SAI 0.39 ODSCC TSP AXIAL PLUGGED 4

8 38 H01-.06 DSI 0.7 ODSCC TSP AXIAL In Service via APC 4

8 39 H01+.00 DSI 1.03 ODSCC TSP AXIAL In Service via APC 4

8 39 H01-.04 SAI 0.35 ODSCC TSP AXIAL In Service via APC 4

8 39 H01+.20 SAI 0.52 ODSCC TSP AXIAL In Service via APC 4

8 39 H03+.00 DSI 0.38 ODSCC TSP AXIAL In Service via APC 4

8 40 H01+.08 DSI 0.4 ODSCC TSP AXIAL In Service via APC 4

8 41 H01+.06 DSI 1.43 ODSCC TSP AXIAL In Service via APC 4

8 41 H01+.19 SAI 0.46 ODSCC TSP AXIAL In Service via APC 4

8 41 H04-.17 DSI 0.51 ODSCC TSP AXIAL In Service via APC 4

8 42 H01+.06 DSI 1.05 ODSCC TSP AXIAL In Service via APC 4

8 42 H01+.03 SAI 0.13 ODSCC TSP AXIAL In Service via APC 4

8 42 H01+.07 SAI 0.07 ODSCC TSP AXIAL In Service via APC 4

8 42 H01+.09 SAI 0.14 ODSCC TSP AXIAL In Service via APC 4

8 42 H01+.19 SAI 0.4 ODSCC TSP AXIAL In Service via APC 4

8 42 H03+.00 DSI 0.66 ODSCC TSP AXIAL In Service via APC 4

8 43 H01-.03 DSI 0.25 ODSCC TSP AXIAL In Service via APC 4

8 43 H04-.08 DSI 0.69 ODSCC TSP AXIAL In Service via APC 4

8 44 H02-.03 DSI 0.4 ODSCC TSP AXIAL In Service via APC 4

8 44 H03+.00 DSI 0.4 ODSCC TSP AXIAL In Service via APC 4

8 45 H01-.09 DSI 0.57 ODSCC TSP AXIAL In Service via APC 4

8 47 H01-.12 DSI 0.33 ODSCC TSP AXIAL In Service via APC 4

8 48 H01+.00 DSI 0.96 ODSCC TSP AXIAL In Service via APC 4

8 50 H01+.03 DSI 1

ODSCC TSP AXIAL In Service via APC 4

8 50 H01+.18 SAI 0.21 ODSCC TSP AXIAL In Service via APC 4

8 50 H01+.20 SAI 0.27 ODSCC TSP AXIAL In Service via APC 4

8 52 H01-.14 DSI 1.28 ODSCC TSP AXIAL In Service via APC 4

8 52 H01+.11 SAI 0.17 ODSCC TSP AXIAL In Service via APC 4

8 52 H01+.16 SAI 0.29 ODSCC TSP AXIAL In Service via APC 4

8 52 H01+.21 SAI 0.42 ODSCC TSP AXIAL In Service via APC 4

8 55 H01+.03 DSI 0.83 ODSCC TSP AXIAL In Service via APC 4

8 56 H01+.03 DSI 0.79 ODSCC TSP AXIAL In Service via APC 4

8 58 H01-.09 DSI 0.59 ODSCC TSP AXIAL In Service via APC 4

8 59 H01-.06 DSI 1.24 ODSCC TSP AXIAL In Service via APC 4

8 59 H01+.02 SAI 0.19 ODSCC TSP AXIAL In Service via APC 4

8 59 H01+.12 SAI 0.45 ODSCC TSP AXIAL In Service via APC 4

8 59 H01+.14 SAI 0.29 ODSCC TSP AXIAL In Service via APC 4

8 60 H01-.09 DSI 1.54 ODSCC TSP AXIAL In Service via APC 4

8 60 H01+.08 SAI 0.25 ODSCC TSP AXIAL In Service via APC 4

8 60 H01+.11 SAI 0.41 ODSCC TSP AXIAL In Service via APC 4

8 60 H01+.12 SAI 0.13 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 57 of 88 4

8 62 H01+.06 DSI 0.43 ODSCC TSP AXIAL In Service via APC 4

8 67 H03+.03 DSI 0.64 ODSCC TSP AXIAL In Service via APC 4

8 70 H01+.03 DSI 0.66 ODSCC TSP AXIAL In Service via APC 4

8 71 H01+.03 DSI 0.98 ODSCC TSP AXIAL In Service via APC 4

8 71 H04-.09 DSI 0.56 ODSCC TSP AXIAL In Service via APC 4

8 73 H03+.06 DSI 1

ODSCC TSP AXIAL In Service via APC 4

8 73 H03+.22 SAI 0.35 ODSCC TSP AXIAL In Service via APC 4

8 76 H03+.00 DSI 0.52 ODSCC TSP AXIAL In Service via APC 4

8 77 H02+.09 DSI 1.31 ODSCC TSP AXIAL In Service via APC 4

8 78 H01+.09 DSI 0.94 ODSCC TSP AXIAL In Service via APC 4

8 78 H03-.14 DSI 0.61 ODSCC TSP AXIAL In Service via APC 4

8 79 H05-.03 DSI 0.24 ODSCC TSP AXIAL In Service via APC 4

8 80 H01+.00 DSI 0.88 ODSCC TSP AXIAL In Service via APC 4

8 80 H02-.23 DSI 0.73 ODSCC TSP AXIAL In Service via APC 4

8 81 H01-.03 DSI 0.81 ODSCC TSP AXIAL In Service via APC 4

8 81 H02+.09 DSI 0.65 ODSCC TSP AXIAL In Service via APC 4

8 82 H01+.03 DSI 1.06 ODSCC TSP AXIAL In Service via APC 4

8 82 H01+.02 SAI 0.13 ODSCC TSP AXIAL In Service via APC 4

8 82 H01+.26 SAI 0.21 ODSCC TSP AXIAL In Service via APC 4

8 83 H01-.14 DSI 1.65 ODSCC TSP AXIAL In Service via APC 4

8 83 H01+.18 SAI 0.47 ODSCC TSP AXIAL In Service via APC 4

8 83 H01+.21 SAI 0.48 ODSCC TSP AXIAL In Service via APC 4

8 84 H02-.06 DSI 0.64 ODSCC TSP AXIAL In Service via APC 4

8 85 H01+.03 DSI 1.35 ODSCC TSP AXIAL In Service via APC 4

8 85 H01+.04 SAI 0.23 ODSCC TSP AXIAL In Service via APC 4

8 85 H01+.25 SAI 0.51 ODSCC TSP AXIAL In Service via APC 4

8 85 H02+.09 DSI 1.79 ODSCC TSP AXIAL In Service via APC 4

8 85 H02+.08 SAI 0.48 ODSCC TSP AXIAL In Service via APC 4

8 85 H02+.28 SAI 0.49 ODSCC TSP AXIAL In Service via APC 4

8 86 H01+.00 DSI 0.76 ODSCC TSP AXIAL In Service via APC 4

8 89 H01+.09 DSI 1.08 ODSCC TSP AXIAL In Service via APC 4

8 89 H01+.14 SAI 0.27 ODSCC TSP AXIAL In Service via APC 4

8 89 H01+.20 SAI 0.37 ODSCC TSP AXIAL In Service via APC 4

8 89 H02+.00 DSI 0.93 ODSCC TSP AXIAL In Service via APC 4

8 89 H03+.00 DSI 0.85 ODSCC TSP AXIAL In Service via APC 4

8 90 H02+.03 DSI 0.87 ODSCC TSP AXIAL In Service via APC 4

8 91 H02-.09 DSI 0.7 ODSCC TSP AXIAL In Service via APC 4

8 91 H03+.03 DSI 0.97 ODSCC TSP AXIAL In Service via APC 4

8 92 H01+.06 DSI 1.76 ODSCC TSP AXIAL In Service via APC 4

8 92 H01+.26 SAI 0.59 ODSCC TSP AXIAL In Service via APC 4

8 92 H02+.03 DSI 1.29 ODSCC TSP AXIAL In Service via APC 4

8 92 H02+.30 SAI 0.36 ODSCC TSP AXIAL In Service via APC 4

8 92 H02+.33 SAI 0.18 ODSCC TSP AXIAL In Service via APC 4

8 92 H03+.00 DSI 0.63 ODSCC TSP AXIAL In Service via APC 4

8 92 H04-.06 DSI 0.75 ODSCC TSP AXIAL In Service via APC 4

8 93 H03+.14 DSI 0.61 ODSCC TSP AXIAL In Service via APC 4

9 2

H02+.00 DSI 1.21 ODSCC TSP AXIAL In Service via APC 4

9 2

H02+.03 SAI 0.12 ODSCC TSP AXIAL In Service via APC 4

9 10 H02-.09 DSI 0.38 ODSCC TSP AXIAL In Service via APC 4

9 11 H01+.06 DSI 0.55 ODSCC TSP AXIAL In Service via APC 4

9 11 H03+.00 DSI 0.5 ODSCC TSP AXIAL In Service via APC 4

9 12 H01+.00 DSI 0.43 ODSCC TSP AXIAL In Service via APC 4

9 13 H01+.11 DSI 0.41 ODSCC TSP AXIAL In Service via APC 4

9 15 H01+.06 DSI 0.36 ODSCC TSP AXIAL In Service via APC 4

9 15 H06-.03 DSI 0.32 ODSCC TSP AXIAL In Service via APC 4

9 16 H02-.06 DSI 0.46 ODSCC TSP AXIAL In Service via APC 4

9 18 H02+.03 DSI 0.47 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 58 of 88 4

9 19 H02+.09 DSI 0.81 ODSCC TSP AXIAL In Service via APC 4

9 21 H02+.11 DSI 0.95 ODSCC TSP AXIAL In Service via APC 4

9 22 H02+.00 DSI 1.28 ODSCC TSP AXIAL In Service via APC 4

9 22 H02+.30 SAI 0.14 ODSCC TSP AXIAL In Service via APC 4

9 22 H02+.33 SAI 0.26 ODSCC TSP AXIAL In Service via APC 4

9 23 H01-.26 DSI 0.97 ODSCC TSP AXIAL In Service via APC 4

9 23 H02-.06 DSI 0.88 ODSCC TSP AXIAL In Service via APC 4

9 24 H01-.06 DSI 0.89 ODSCC TSP AXIAL In Service via APC 4

9 25 H01+.06 DSI 0.47 ODSCC TSP AXIAL In Service via APC 4

9 28 H02-.17 DSI 0.81 ODSCC TSP AXIAL In Service via APC 4

9 29 H01-.03 DSI 0.68 ODSCC TSP AXIAL In Service via APC 4

9 30 H01+.03 DSI 1.3 ODSCC TSP AXIAL In Service via APC 4

9 30 H01+.29 SAI 0.83 ODSCC TSP AXIAL In Service via APC 4

9 30 H01+.34 SAI 0.46 ODSCC TSP AXIAL In Service via APC 4

9 31 H01-.06 DSI 0.41 ODSCC TSP AXIAL In Service via APC 4

9 33 H01-.11 DSI 0.72 ODSCC TSP AXIAL In Service via APC 4

9 33 H02+.00 DSI 0.23 ODSCC TSP AXIAL In Service via APC 4

9 34 H01-.20 DSI 0.47 ODSCC TSP AXIAL In Service via APC 4

9 35 H01-.17 DSI 1.42 ODSCC TSP AXIAL In Service via APC 4

9 35 H01+.16 SAI 0.46 ODSCC TSP AXIAL In Service via APC 4

9 36 H01-.03 DSI 0.49 ODSCC TSP AXIAL In Service via APC 4

9 36 H02-.14 DSI 0.68 ODSCC TSP AXIAL In Service via APC 4

9 37 H01+.11 DSI 0.7 ODSCC TSP AXIAL In Service via APC 4

9 37 H02-.17 DSI 0.71 ODSCC TSP AXIAL In Service via APC 4

9 38 H01-.06 DSI 1.53 ODSCC TSP AXIAL In Service via APC 4

9 38 H01+.06 SAI 0.39 ODSCC TSP AXIAL In Service via APC 4

9 38 H01+.09 SAI 0.12 ODSCC TSP AXIAL In Service via APC 4

9 38 H01+.15 SAI 0.36 ODSCC TSP AXIAL In Service via APC 4

9 39 H01+.08 DSI 0.62 ODSCC TSP AXIAL In Service via APC 4

9 40 H02+.03 DSI 0.62 ODSCC TSP AXIAL In Service via APC 4

9 42 H01+.08 DSI 1.65 ODSCC TSP AXIAL In Service via APC 4

9 42 H01+.15 SAI 0.3 ODSCC TSP AXIAL In Service via APC 4

9 42 H01+.20 SAI 0.29 ODSCC TSP AXIAL In Service via APC 4

9 42 H01+.25 SAI 0.17 ODSCC TSP AXIAL In Service via APC 4

9 42 H01+.26 SAI 0.2 ODSCC TSP AXIAL In Service via APC 4

9 43 H01+.00 DSI 1.17 ODSCC TSP AXIAL In Service via APC 4

9 43 H01+.15 SAI 0.26 ODSCC TSP AXIAL In Service via APC 4

9 43 H01+.24 SAI 0.22 ODSCC TSP AXIAL In Service via APC 4

9 43 H01+.26 SAI 0.32 ODSCC TSP AXIAL In Service via APC 4

9 43 H02-.17 DSI 0.64 ODSCC TSP AXIAL In Service via APC 4

9 44 H01+.06 DSI 1.16 ODSCC TSP AXIAL In Service via APC 4

9 44 H01+.22 SAI 0.22 ODSCC TSP AXIAL In Service via APC 4

9 44 H01+.24 SAI 0.41 ODSCC TSP AXIAL In Service via APC 4

9 44 H01+.27 SAI 0.22 ODSCC TSP AXIAL In Service via APC 4

9 46 H01+.00 DSI 3.62 ODSCC TSP AXIAL PLUGGED 4

9 46 H01+.17 SAI 0.23 ODSCC TSP AXIAL PLUGGED 4

9 46 H01+.30 SAI 0.18 ODSCC TSP AXIAL PLUGGED 4

9 46 H01+.31 SAI 2.53 ODSCC TSP AXIAL PLUGGED 4

9 46 H03-.09 DSI 0.84 ODSCC TSP AXIAL In Service via APC 4

9 46 H04-.03 DSI 0.19 ODSCC TSP AXIAL In Service via APC 4

9 46 H06+.00 DSI 0.18 ODSCC TSP AXIAL In Service via APC 4

9 47 H01-.12 DSI 0.66 ODSCC TSP AXIAL In Service via APC 4

9 47 H03+.00 DSI 0.54 ODSCC TSP AXIAL In Service via APC 4

9 48 H01-.23 DSI 1.19 ODSCC TSP AXIAL In Service via APC 4

9 48 H01-.05 SAI 0.23 ODSCC TSP AXIAL In Service via APC 4

9 48 H01+.33 SAI 0.16 ODSCC TSP AXIAL In Service via APC 4

9 48 H01+.34 SAI 0.46 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 59 of 88 4

9 48 H03-.03 DSI 0.71 ODSCC TSP AXIAL In Service via APC 4

9 50 H01-.06 DSI 0.42 ODSCC TSP AXIAL In Service via APC 4

9 52 H01-.06 DSI 0.41 ODSCC TSP AXIAL In Service via APC 4

9 53 H01-.03 DSI 1.02 ODSCC TSP AXIAL In Service via APC 4

9 53 H01+.17 SAI 0.35 ODSCC TSP AXIAL In Service via APC 4

9 53 H01+.25 SAI 0.19 ODSCC TSP AXIAL In Service via APC 4

9 57 H01-.03 DSI 1.25 ODSCC TSP AXIAL In Service via APC 4

9 57 H01+.06 SAI 0.13 ODSCC TSP AXIAL In Service via APC 4

9 57 H01+.08 SAI 0.26 ODSCC TSP AXIAL In Service via APC 4

9 57 H01+.17 SAI 0.21 ODSCC TSP AXIAL In Service via APC 4

9 61 H01+.06 DSI 0.69 ODSCC TSP AXIAL In Service via APC 4

9 63 H01-.14 DSI 0.78 ODSCC TSP AXIAL In Service via APC 4

9 64 H03-.06 DSI 0.65 ODSCC TSP AXIAL In Service via APC 4

9 70 H01+.03 DSI 0.87 ODSCC TSP AXIAL In Service via APC 4

9 73 H01+.03 DSI 0.9 ODSCC TSP AXIAL In Service via APC 4

9 74 H04-.03 DSI 0.39 ODSCC TSP AXIAL In Service via APC 4

9 74 H05-.03 DSI 0.44 ODSCC TSP AXIAL In Service via APC 4

9 77 C04-.08 DSI 0.38 ODSCC TSP AXIAL In Service via APC 4

9 83 H01-.03 DSI 0.65 ODSCC TSP AXIAL In Service via APC 4

9 89 H01-.09 DSI 0.61 ODSCC TSP AXIAL In Service via APC 4

9 89 H02+.00 DSI 1.12 ODSCC TSP AXIAL In Service via APC 4

9 93 H02+.00 DSI 0.72 ODSCC TSP AXIAL In Service via APC 4

10 3

H02+.12 DSI 0.77 ODSCC TSP AXIAL In Service via APC 4

10 12 H02+.11 DSI 1.05 ODSCC TSP AXIAL In Service via APC 4

10 12 H02+.29 SAI 0.15 ODSCC TSP AXIAL In Service via APC 4

10 20 H02+.14 DSI 0.74 ODSCC TSP AXIAL In Service via APC 4

10 29 H01+.11 DSI 0.27 ODSCC TSP AXIAL In Service via APC 4

10 31 H01+.08 DSI 0.6 ODSCC TSP AXIAL In Service via APC 4

10 35 H01-.11 DSI 0.95 ODSCC TSP AXIAL In Service via APC 4

10 36 H01+.00 DSI 0.42 ODSCC TSP AXIAL In Service via APC 4

10 42 H01+.06 DSI 0.61 ODSCC TSP AXIAL In Service via APC 4

10 42 H03+.08 DSI 0.59 ODSCC TSP AXIAL In Service via APC 4

10 52 H01+.00 DSI 0.91 ODSCC TSP AXIAL In Service via APC 4

10 68 H03+.00 DSI 0.76 ODSCC TSP AXIAL In Service via APC 4

11 42 H01+.08 DSI 0.69 ODSCC TSP AXIAL In Service via APC 4

11 68 H07+.11 DSI 0.38 ODSCC TSP AXIAL In Service via APC 4

11 69 H03+.00 DSI 0.33 ODSCC TSP AXIAL In Service via APC 4

11 69 H04-.03 DSI 0.4 ODSCC TSP AXIAL In Service via APC 4

11 75 H02-.06 DSI 0.97 ODSCC TSP AXIAL In Service via APC 4

11 84 H04-.08 DSI 0.47 ODSCC TSP AXIAL In Service via APC 4

12 2

H02+.12 DSI 1.13 ODSCC TSP AXIAL In Service via APC 4

12 2

H02+.10 SAI 0.21 ODSCC TSP AXIAL In Service via APC 4

12 10 H03+.06 DSI 0.76 ODSCC TSP AXIAL In Service via APC 4

12 11 H03+.11 DSI 0.32 ODSCC TSP AXIAL In Service via APC 4

12 15 H04+.17 DSI 0.37 ODSCC TSP AXIAL In Service via APC 4

12 18 H02+.14 DSI 0.95 ODSCC TSP AXIAL In Service via APC 4

12 21 H01+.06 DSI 1.78 ODSCC TSP AXIAL PLUGGED-Preventive 4

12 21 H01+.06 SAI 0.45 ODSCC TSP AXIAL PLUGGED-Preventive 4

12 21 H01+.34 SAI 1.34 ODSCC TSP AXIAL PLUGGED-Preventive 4

12 21 H02+.00 DSI 1.02 ODSCC TSP AXIAL In Service via APC 4

12 21 H02+.03 SAI 0.23 ODSCC TSP AXIAL In Service via APC 4

12 21 H02+.12 SAI 0.16 ODSCC TSP AXIAL In Service via APC 4

12 21 H02+.20 SAI 0.17 ODSCC TSP AXIAL In Service via APC 4

12 23 H01+.08 DSI 0.87 ODSCC TSP AXIAL In Service via APC 4

12 24 H01+.25 DSI 1.11 ODSCC TSP AXIAL In Service via APC 4

12 24 H01+.32 SAI 0.3 ODSCC TSP AXIAL In Service via APC 4

12 24 H01+.33 SAI 0.22 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 60 of 88 4

12 24 H02+.30 DSI 0.55 ODSCC TSP AXIAL In Service via APC 4

12 25 H03-.08 DSI 0.59 ODSCC TSP AXIAL In Service via APC 4

12 26 H01+.17 DSI 0.65 ODSCC TSP AXIAL In Service via APC 4

12 26 H02+.06 DSI 0.46 ODSCC TSP AXIAL In Service via APC 4

12 27 H01+.11 DSI 0.55 ODSCC TSP AXIAL In Service via APC 4

12 30 H01+.19 DSI 0.86 ODSCC TSP AXIAL In Service via APC 4

12 31 H03+.08 DSI 0.65 ODSCC TSP AXIAL In Service via APC 4

12 32 H01+.06 DSI 1.37 ODSCC TSP AXIAL In Service via APC 4

12 32 H01+.13 SAI 0.13 ODSCC TSP AXIAL In Service via APC 4

12 32 H01+.19 SAI 0.18 ODSCC TSP AXIAL In Service via APC 4

12 32 H01+.24 SAI 0.36 ODSCC TSP AXIAL In Service via APC 4

12 32 H01+.25 SAI 0.25 ODSCC TSP AXIAL In Service via APC 4

12 33 H04+.22 DSI 1.13 ODSCC TSP AXIAL In Service via APC 4

12 33 H04+.31 SAI 0.7 ODSCC TSP AXIAL In Service via APC 4

12 34 H02-.11 DSI 1.56 ODSCC TSP AXIAL In Service via APC 4

12 34 H02+.37 SAI 0.94 ODSCC TSP AXIAL In Service via APC 4

12 35 H01+.11 DSI 0.84 ODSCC TSP AXIAL In Service via APC 4

12 36 H01+.11 DSI 0.7 ODSCC TSP AXIAL In Service via APC 4

12 36 H02+.20 DSI 0.42 ODSCC TSP AXIAL In Service via APC 4

12 37 H02-.14 DSI 0.98 ODSCC TSP AXIAL In Service via APC 4

12 38 H01+.00 DSI 0.52 ODSCC TSP AXIAL In Service via APC 4

12 38 H05+.14 DSI 0.82 ODSCC TSP AXIAL In Service via APC 4

12 39 H01+.03 DSI 0.48 ODSCC TSP AXIAL In Service via APC 4

12 39 H04+.06 DSI 0.35 ODSCC TSP AXIAL In Service via APC 4

12 39 H06+.03 DSI 0.73 ODSCC TSP AXIAL In Service via APC 4

12 40 H01+.08 DSI 0.78 ODSCC TSP AXIAL In Service via APC 4

12 41 H01+.06 DSI 0.97 ODSCC TSP AXIAL In Service via APC 4

12 41 H03+.11 DSI 0.52 ODSCC TSP AXIAL In Service via APC 4

12 42 H01+.08 DSI 0.53 ODSCC TSP AXIAL In Service via APC 4

12 43 H01+.20 DSI 1.48 ODSCC TSP AXIAL In Service via APC 4

12 43 H01+.05 SAI 0.25 ODSCC TSP AXIAL In Service via APC 4

12 43 H01+.34 SAI 0.89 ODSCC TSP AXIAL In Service via APC 4

12 43 H03+.14 DSI 0.62 ODSCC TSP AXIAL In Service via APC 4

12 44 H01+.14 DSI 0.86 ODSCC TSP AXIAL In Service via APC 4

12 59 H01+.00 DSI 0.85 ODSCC TSP AXIAL In Service via APC 4

12 59 H05+.15 DSI 0.51 ODSCC TSP AXIAL In Service via APC 4

12 61 H01+.00 DSI 1.09 ODSCC TSP AXIAL In Service via APC 4

12 61 H01+.09 SAI 0.1 ODSCC TSP AXIAL In Service via APC 4

12 61 H01+.14 SAI 0.19 ODSCC TSP AXIAL In Service via APC 4

12 62 H01-.17 DSI 0.97 ODSCC TSP AXIAL In Service via APC 4

12 63 H01+.00 DSI 1.07 ODSCC TSP AXIAL In Service via APC 4

12 63 H01-.05 SAI 0.15 ODSCC TSP AXIAL In Service via APC 4

12 63 H01+.00 SAI 0.11 ODSCC TSP AXIAL In Service via APC 4

12 63 H01+.01 SAI 0.1 ODSCC TSP AXIAL In Service via APC 4

12 71 H01-.06 DSI 0.85 ODSCC TSP AXIAL In Service via APC 4

12 74 H01-.14 DSI 0.77 ODSCC TSP AXIAL In Service via APC 4

12 74 H02-.06 DSI 0.25 ODSCC TSP AXIAL In Service via APC 4

12 75 H01-.20 DSI 0.82 ODSCC TSP AXIAL In Service via APC 4

12 75 H02-.03 DSI 0.45 ODSCC TSP AXIAL In Service via APC 4

12 76 H01-.20 DSI 1.39 ODSCC TSP AXIAL In Service via APC 4

12 76 H01+.18 SAI 0.72 ODSCC TSP AXIAL In Service via APC 4

12 76 H05-.03 DSI 0.63 ODSCC TSP AXIAL In Service via APC 4

12 81 H01-.03 DSI 0.75 ODSCC TSP AXIAL In Service via APC 4

12 81 H03-.12 DSI 0.71 ODSCC TSP AXIAL In Service via APC 4

12 82 H01-.03 DSI 0.87 ODSCC TSP AXIAL In Service via APC 4

12 83 H01-.06 DSI 1.42 ODSCC TSP AXIAL In Service via APC 4

12 83 H01+.09 SAI 0.22 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 61 of 88 4

12 83 H01+.12 SAI 0.58 ODSCC TSP AXIAL In Service via APC 4

12 85 H01-.15 DSI 0.78 ODSCC TSP AXIAL In Service via APC 4

13 14 H02+.20 DSI 0.55 ODSCC TSP AXIAL In Service via APC 4

13 15 H01+.22 DSI 0.9 ODSCC TSP AXIAL In Service via APC 4

13 15 H02-.14 DSI 0.89 ODSCC TSP AXIAL In Service via APC 4

13 15 H02+.22 DSI 0.74 ODSCC TSP AXIAL In Service via APC 4

13 17 H01-.17 DSI 0.69 ODSCC TSP AXIAL In Service via APC 4

13 17 H01+.25 DSI 0.66 ODSCC TSP AXIAL In Service via APC 4

13 17 H02-.14 DSI 0.78 ODSCC TSP AXIAL In Service via APC 4

13 17 H02+.28 DSI 1.03 ODSCC TSP AXIAL In Service via APC 4

13 17 H02-.09 SAI 0.12 ODSCC TSP AXIAL In Service via APC 4

13 17 H02+.32 SAI 0.23 ODSCC TSP AXIAL In Service via APC 4

13 17 H02+.33 SAI 0.24 ODSCC TSP AXIAL In Service via APC 4

13 17 H02+.37 SAI 0.3 ODSCC TSP AXIAL In Service via APC 4

13 17 H03+.06 DSI 0.28 ODSCC TSP AXIAL In Service via APC 4

13 29 H02-.03 DSI 0.52 ODSCC TSP AXIAL In Service via APC 4

13 30 H02-.14 DSI 0.88 ODSCC TSP AXIAL In Service via APC 4

13 31 H02-.14 DSI 0.44 ODSCC TSP AXIAL In Service via APC 4

13 33 H01+.14 DSI 0.46 ODSCC TSP AXIAL In Service via APC 4

13 34 H01+.11 DSI 1.03 ODSCC TSP AXIAL In Service via APC 4

13 34 H01+.33 SAI 0.37 ODSCC TSP AXIAL In Service via APC 4

13 35 H02+.11 DSI 0.77 ODSCC TSP AXIAL In Service via APC 4

13 36 H02+.00 DSI 0.22 ODSCC TSP AXIAL In Service via APC 4

13 39 H02+.19 DSI 0.55 ODSCC TSP AXIAL In Service via APC 4

13 41 H03+.20 DSI 1.45 ODSCC TSP AXIAL In Service via APC 4

13 41 H03+.25 SAI 0.3 ODSCC TSP AXIAL In Service via APC 4

13 41 H03+.26 SAI 0.21 ODSCC TSP AXIAL In Service via APC 4

13 42 H01+.06 DSI 0.95 ODSCC TSP AXIAL In Service via APC 4

13 43 H03+.08 DSI 0.38 ODSCC TSP AXIAL In Service via APC 4

13 44 H01+.06 DSI 0.69 ODSCC TSP AXIAL In Service via APC 4

13 44 H02+.14 DSI 0.38 ODSCC TSP AXIAL In Service via APC 4

13 45 H01+.06 DSI 0.91 ODSCC TSP AXIAL In Service via APC 4

13 46 H01+.11 DSI 0.46 ODSCC TSP AXIAL In Service via APC 4

13 46 H03-.03 DSI 0.31 ODSCC TSP AXIAL In Service via APC 4

13 47 H01+.00 DSI 0.88 ODSCC TSP AXIAL In Service via APC 4

13 47 H04-.08 DSI 0.49 ODSCC TSP AXIAL In Service via APC 4

13 48 H01-.06 DSI 1.74 ODSCC TSP AXIAL In Service via APC 4

13 48 H01+.22 SAI 0.39 ODSCC TSP AXIAL In Service via APC 4

13 48 H01+.26 SAI 0.68 ODSCC TSP AXIAL In Service via APC 4

13 48 H04-.03 DSI 0.47 ODSCC TSP AXIAL In Service via APC 4

13 49 H01-.03 DSI 1.33 ODSCC TSP AXIAL In Service via APC 4

13 49 H01+.17 SAI 0.29 ODSCC TSP AXIAL In Service via APC 4

13 49 H01+.25 SAI 0.19 ODSCC TSP AXIAL In Service via APC 4

13 49 H03-.09 DSI 0.4 ODSCC TSP AXIAL In Service via APC 4

13 50 H03-.20 DSI 0.9 ODSCC TSP AXIAL In Service via APC 4

13 51 H01-.03 DSI 0.49 ODSCC TSP AXIAL In Service via APC 4

13 52 H01+.03 DSI 0.72 ODSCC TSP AXIAL In Service via APC 4

13 53 H01+.00 DSI 1.11 ODSCC TSP AXIAL In Service via APC 4

13 53 H01+.17 SAI 0.34 ODSCC TSP AXIAL In Service via APC 4

13 53 H01+.25 SAI 0.36 ODSCC TSP AXIAL In Service via APC 4

13 54 H01+.00 DSI 0.78 ODSCC TSP AXIAL In Service via APC 4

13 57 H01-.06 DSI 0.73 ODSCC TSP AXIAL In Service via APC 4

13 57 H05-.15 DSI 0.58 ODSCC TSP AXIAL In Service via APC 4

13 59 H02+.00 DSI 0.48 ODSCC TSP AXIAL In Service via APC 4

13 62 H01+.06 DSI 0.47 ODSCC TSP AXIAL In Service via APC 4

13 68 H02-.03 DSI 0.54 ODSCC TSP AXIAL In Service via APC 4

13 70 H01-.14 DSI 0.57 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 62 of 88 4

13 77 H01-.23 DSI 0.56 ODSCC TSP AXIAL In Service via APC 4

13 81 H03-.03 DSI 0.67 ODSCC TSP AXIAL In Service via APC 4

13 82 H02-.14 DSI 0.58 ODSCC TSP AXIAL In Service via APC 4

13 84 H01+.09 DSI 1.97 ODSCC TSP AXIAL In Service via APC 4

13 84 H02+.00 DSI 1.38 ODSCC TSP AXIAL In Service via APC 4

13 86 H01+.08 DSI 1.22 ODSCC TSP AXIAL In Service via APC 4

13 86 H01-.11 SAI 0.13 ODSCC TSP AXIAL In Service via APC 4

14 13 H02+.00 DSI 0.2 ODSCC TSP AXIAL In Service via APC 4

14 22 H01+.08 DSI 1.48 ODSCC TSP AXIAL In Service via APC 4

14 22 H01+.18 SAI 0.49 ODSCC TSP AXIAL In Service via APC 4

14 22 H02-.06 DSI 0.77 ODSCC TSP AXIAL In Service via APC 4

14 24 H01+.14 DSI 0.93 ODSCC TSP AXIAL In Service via APC 4

14 57 H01-.06 DSI 1.57 ODSCC TSP AXIAL In Service via APC 4

14 57 H01+.12 SAI 0.35 ODSCC TSP AXIAL In Service via APC 4

14 57 H01+.15 SAI 0.36 ODSCC TSP AXIAL In Service via APC 4

14 57 H01+.19 SAI 0.34 ODSCC TSP AXIAL In Service via APC 4

14 59 H01+.09 DSI 1.06 ODSCC TSP AXIAL In Service via APC 4

14 59 H01+.22 SAI 0.3 ODSCC TSP AXIAL In Service via APC 4

14 59 H01+.24 SAI 0.26 ODSCC TSP AXIAL In Service via APC 4

14 59 H01+.26 SAI 0.12 ODSCC TSP AXIAL In Service via APC 4

14 60 H01-.03 DSI 0.6 ODSCC TSP AXIAL In Service via APC 4

14 75 H02-.11 DSI 0.7 ODSCC TSP AXIAL In Service via APC 4

14 77 H01+.03 DSI 1.53 ODSCC TSP AXIAL In Service via APC 4

14 77 H01-.06 SAI 0.2 ODSCC TSP AXIAL In Service via APC 4

14 77 H02+.00 DSI 0.63 ODSCC TSP AXIAL In Service via APC 4

14 77 H02+.15 SAI 0.2 ODSCC TSP AXIAL In Service via APC 4

14 77 H02+.35 SAI 0.31 ODSCC TSP AXIAL In Service via APC 4

14 79 H02-.23 DSI 0.68 ODSCC TSP AXIAL In Service via APC 4

14 81 H02-.06 DSI 0.56 ODSCC TSP AXIAL In Service via APC 4

14 82 H01-.03 DSI 1.48 ODSCC TSP AXIAL In Service via APC 4

14 82 H01-.03 SAI 0.23 ODSCC TSP AXIAL In Service via APC 4

14 83 H01-.06 DSI 1.28 ODSCC TSP AXIAL In Service via APC 4

14 83 H01+.15 SAI 0.14 ODSCC TSP AXIAL In Service via APC 4

14 83 H01+.23 SAI 0.31 ODSCC TSP AXIAL In Service via APC 4

14 85 H01+.00 DSI 0.43 ODSCC TSP AXIAL In Service via APC 4

14 86 H01-.03 DSI 1.29 ODSCC TSP AXIAL In Service via APC 4

14 86 H01+.21 SAI 0.14 ODSCC TSP AXIAL In Service via APC 4

14 86 H01+.24 SAI 0.27 ODSCC TSP AXIAL In Service via APC 4

14 86 H02+.06 DSI 1.15 ODSCC TSP AXIAL In Service via APC 4

14 86 H02+.19 SAI 0.12 ODSCC TSP AXIAL In Service via APC 4

14 86 H04-.06 DSI 0.89 ODSCC TSP AXIAL In Service via APC 4

14 88 H01-.03 DSI 1.38 ODSCC TSP AXIAL In Service via APC 4

14 88 H01+.01 SAI 0.17 ODSCC TSP AXIAL In Service via APC 4

14 88 H01+.32 SAI 0.34 ODSCC TSP AXIAL In Service via APC 4

14 88 H03+.03 DSI 0.66 ODSCC TSP AXIAL In Service via APC 4

14 89 H01+.00 DSI 1.2 ODSCC TSP AXIAL In Service via APC 4

14 89 H01+.06 SAI 0.26 ODSCC TSP AXIAL In Service via APC 4

14 90 H01+.20 DSI 1.21 ODSCC TSP AXIAL In Service via APC 4

14 90 H01+.27 SAI 0.37 ODSCC TSP AXIAL In Service via APC 4

14 90 H02+.20 DSI 0.99 ODSCC TSP AXIAL In Service via APC 4

14 91 H01-.03 DSI 0.69 ODSCC TSP AXIAL In Service via APC 4

14 92 H01+.00 DSI 1.58 ODSCC TSP AXIAL In Service via APC 4

14 92 H01+.21 SAI 0.15 ODSCC TSP AXIAL In Service via APC 4

14 92 H01+.29 SAI 0.26 ODSCC TSP AXIAL In Service via APC 4

15 4

H02+.06 DSI 0.57 ODSCC TSP AXIAL In Service via APC 4

15 22 C05-.03 DSI 0.31 ODSCC TSP AXIAL In Service via APC 4

15 48 H01-.03 DSI 1.19 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 63 of 88 4

15 48 H01+.11 SAI 0.17 ODSCC TSP AXIAL In Service via APC 4

15 48 H01+.20 SAI 0.35 ODSCC TSP AXIAL In Service via APC 4

15 48 H03+.06 DSI 0.5 ODSCC TSP AXIAL In Service via APC 4

15 49 H01-.12 DSI 0.85 ODSCC TSP AXIAL In Service via APC 4

15 49 H03-.09 DSI 2.11 ODSCC TSP AXIAL PLUGGED 4

15 49 H03+.11 SAI 0.3 ODSCC TSP AXIAL PLUGGED 4

15 49 H04-.15 DSI 0.5 ODSCC TSP AXIAL In Service via APC 4

15 49 H05+.00 DSI 0.23 ODSCC TSP AXIAL In Service via APC 4

15 50 H01-.08 DSI 0.93 ODSCC TSP AXIAL In Service via APC 4

15 50 H02+.06 DSI 0.47 ODSCC TSP AXIAL In Service via APC 4

15 51 H01-.06 DSI 1.05 ODSCC TSP AXIAL In Service via APC 4

15 51 H01+.04 SAI 0.26 ODSCC TSP AXIAL In Service via APC 4

15 51 H01+.17 SAI 0.13 ODSCC TSP AXIAL In Service via APC 4

15 51 H01+.30 SAI 0.18 ODSCC TSP AXIAL In Service via APC 4

15 52 H01-.03 DSI 1.72 ODSCC TSP AXIAL In Service via APC 4

15 52 H01+.11 SAI 0.23 ODSCC TSP AXIAL In Service via APC 4

15 52 H01+.24 SAI 0.38 ODSCC TSP AXIAL In Service via APC 4

15 53 H01+.00 DSI 1.29 ODSCC TSP AXIAL In Service via APC 4

15 53 H01+.07 SAI 0.19 ODSCC TSP AXIAL In Service via APC 4

15 53 H01+.16 SAI 0.4 ODSCC TSP AXIAL In Service via APC 4

15 53 H01+.20 SAI 0.16 ODSCC TSP AXIAL In Service via APC 4

15 53 H01+.25 SAI 0.24 ODSCC TSP AXIAL In Service via APC 4

15 54 H01+.00 DSI 0.97 ODSCC TSP AXIAL In Service via APC 4

15 54 H02+.08 DSI 0.44 ODSCC TSP AXIAL In Service via APC 4

15 61 H01+.00 DSI 0.68 ODSCC TSP AXIAL In Service via APC 4

15 62 H01-.11 DSI 0.7 ODSCC TSP AXIAL In Service via APC 4

15 63 H01+.03 DSI 0.67 ODSCC TSP AXIAL In Service via APC 4

15 63 H05-.03 DSI 0.71 ODSCC TSP AXIAL In Service via APC 4

15 64 H01+.14 DSI 0.8 ODSCC TSP AXIAL In Service via APC 4

15 65 H01+.03 DSI 0.63 ODSCC TSP AXIAL In Service via APC 4

15 65 H03-.08 DSI 0.63 ODSCC TSP AXIAL In Service via APC 4

15 65 H05-.03 DSI 0.71 ODSCC TSP AXIAL In Service via APC 4

15 66 H01-.06 DSI 0.34 ODSCC TSP AXIAL In Service via APC 4

15 67 H01+.09 DSI 0.75 ODSCC TSP AXIAL In Service via APC 4

15 69 H01+.00 DSI 0.58 ODSCC TSP AXIAL In Service via APC 4

16 23 H05+.23 DSI 0.72 ODSCC TSP AXIAL In Service via APC 4

16 35 H01+.14 DSI 0.39 ODSCC TSP AXIAL In Service via APC 4

16 43 H01+.06 DSI 0.45 ODSCC TSP AXIAL In Service via APC 4

16 45 H01+.03 DSI 0.44 ODSCC TSP AXIAL In Service via APC 4

16 50 H01-.03 DSI 0.89 ODSCC TSP AXIAL In Service via APC 4

16 59 H01-.09 DSI 0.99 ODSCC TSP AXIAL In Service via APC 4

16 61 H01-.06 DSI 0.82 ODSCC TSP AXIAL In Service via APC 4

16 80 H03-.03 DSI 0.72 ODSCC TSP AXIAL In Service via APC 4

16 83 H01+.06 DSI 0.73 ODSCC TSP AXIAL In Service via APC 4

16 89 H01-.03 DSI 1.33 ODSCC TSP AXIAL In Service via APC 4

16 89 H01+.28 SAI 0.13 ODSCC TSP AXIAL In Service via APC 4

16 91 H01+.00 DSI 1.03 ODSCC TSP AXIAL In Service via APC 4

17 9

H02+.20 DSI 0.37 ODSCC TSP AXIAL In Service via APC 4

17 13 H02+.20 DSI 0.74 ODSCC TSP AXIAL In Service via APC 4

17 15 H02+.03 DSI 0.86 ODSCC TSP AXIAL In Service via APC 4

17 15 H02+.04 SAI 0.13 ODSCC TSP AXIAL In Service via APC 4

17 15 H02+.31 SAI 0.31 ODSCC TSP AXIAL In Service via APC 4

17 21 H01+.14 DSI 1.35 ODSCC TSP AXIAL In Service via APC 4

17 21 H01+.13 SAI 0.12 ODSCC TSP AXIAL In Service via APC 4

17 21 H01+.22 SAI 0.15 ODSCC TSP AXIAL In Service via APC 4

17 21 H01+.24 SAI 0.25 ODSCC TSP AXIAL In Service via APC 4

17 21 H01+.25 SAI 0.11 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 64 of 88 4

17 21 H04+.11 DSI 0.83 ODSCC TSP AXIAL In Service via APC 4

17 26 H02-.15 DSI 0.92 ODSCC TSP AXIAL In Service via APC 4

17 26 H02+.23 DSI 1.24 ODSCC TSP AXIAL In Service via APC 4

17 26 H02-.09 SAI 0.14 ODSCC TSP AXIAL In Service via APC 4

17 26 H02+.20 SAI 0.33 ODSCC TSP AXIAL In Service via APC 4

17 26 H02+.29 SAI 0.28 ODSCC TSP AXIAL In Service via APC 4

17 27 H01+.06 DSI 1.55 ODSCC TSP AXIAL In Service via APC 4

17 27 H01+.13 SAI 0.19 ODSCC TSP AXIAL In Service via APC 4

17 27 H01+.16 SAI 0.25 ODSCC TSP AXIAL In Service via APC 4

17 27 H01+.17 SAI 0.13 ODSCC TSP AXIAL In Service via APC 4

17 27 H01+.24 SAI 0.3 ODSCC TSP AXIAL In Service via APC 4

17 27 H03-.09 DSI 0.22 ODSCC TSP AXIAL In Service via APC 4

17 29 H01+.08 DSI 0.65 ODSCC TSP AXIAL In Service via APC 4

17 30 H01+.06 DSI 0.47 ODSCC TSP AXIAL In Service via APC 4

17 30 H02-.08 DSI 0.71 ODSCC TSP AXIAL In Service via APC 4

17 31 H04-.06 DSI 0.66 ODSCC TSP AXIAL In Service via APC 4

17 32 H01+.11 DSI 0.45 ODSCC TSP AXIAL In Service via APC 4

17 55 H01+.00 DSI 0.68 ODSCC TSP AXIAL In Service via APC 4

17 55 H05-.06 DSI 0.57 ODSCC TSP AXIAL In Service via APC 4

17 56 H01-.06 DSI 0.91 ODSCC TSP AXIAL In Service via APC 4

17 56 H02+.00 DSI 0.45 ODSCC TSP AXIAL In Service via APC 4

17 57 H01-.09 DSI 0.73 ODSCC TSP AXIAL In Service via APC 4

17 58 H01-.03 DSI 0.62 ODSCC TSP AXIAL In Service via APC 4

17 58 H03-.06 DSI 0.85 ODSCC TSP AXIAL In Service via APC 4

17 61 H01-.03 DSI 0.88 ODSCC TSP AXIAL In Service via APC 4

17 62 H01+.00 DSI 0.64 ODSCC TSP AXIAL In Service via APC 4

17 72 H01-.03 DSI 0.79 ODSCC TSP AXIAL In Service via APC 4

17 75 H01-.03 DSI 0.73 ODSCC TSP AXIAL In Service via APC 4

17 76 H01-.06 DSI 0.6 ODSCC TSP AXIAL In Service via APC 4

17 78 H01+.03 DSI 0.44 ODSCC TSP AXIAL In Service via APC 4

17 80 H01-.14 DSI 0.38 ODSCC TSP AXIAL In Service via APC 4

17 81 H01+.06 DSI 0.7 ODSCC TSP AXIAL In Service via APC 4

17 81 H01+.18 SAI 0.26 ODSCC TSP AXIAL In Service via APC 4

17 82 H01-.03 DSI 1.51 ODSCC TSP AXIAL In Service via APC 4

17 82 H01+.08 SAI 0.6 ODSCC TSP AXIAL In Service via APC 4

17 82 H01+.12 SAI 0.17 ODSCC TSP AXIAL In Service via APC 4

17 82 H01+.28 SAI 0.21 ODSCC TSP AXIAL In Service via APC 4

17 83 H01+.00 DSI 0.45 ODSCC TSP AXIAL In Service via APC 4

17 84 H01+.00 DSI 0.81 ODSCC TSP AXIAL In Service via APC 4

17 85 H01-.03 DSI 0.5 ODSCC TSP AXIAL In Service via APC 4

17 87 H01-.03 DSI 1.61 ODSCC TSP AXIAL In Service via APC 4

17 87 H01+.25 SAI 0.38 ODSCC TSP AXIAL In Service via APC 4

17 87 H01+.30 SAI 0.57 ODSCC TSP AXIAL In Service via APC 4

17 88 H02-.06 DSI 0.42 ODSCC TSP AXIAL In Service via APC 4

17 91 H01+.00 DSI 0.77 ODSCC TSP AXIAL In Service via APC 4

18 11 H04+.08 DSI 0.26 ODSCC TSP AXIAL In Service via APC 4

18 13 C05+.03 DSI 0.54 ODSCC TSP AXIAL In Service via APC 4

18 14 H02-.11 DSI 0.97 ODSCC TSP AXIAL In Service via APC 4

18 14 H02+.25 DSI 1.22 ODSCC TSP AXIAL In Service via APC 4

18 14 H02-.04 SAI 0.31 ODSCC TSP AXIAL In Service via APC 4

18 14 H02-.03 SAI 0.16 ODSCC TSP AXIAL In Service via APC 4

18 14 H02+.34 SAI 0.35 ODSCC TSP AXIAL In Service via APC 4

18 15 H01+.03 DSI 0.42 ODSCC TSP AXIAL In Service via APC 4

18 15 H02+.06 DSI 0.26 ODSCC TSP AXIAL In Service via APC 4

18 15 H03+.03 DSI 0.24 ODSCC TSP AXIAL In Service via APC 4

18 15 H04+.20 DSI 0.27 ODSCC TSP AXIAL In Service via APC 4

18 16 H05+.00 DSI 0.37 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 65 of 88 4

18 21 H01+.11 DSI 0.73 ODSCC TSP AXIAL In Service via APC 4

18 21 H02+.17 DSI 0.41 ODSCC TSP AXIAL In Service via APC 4

18 24 H02+.14 DSI 0.42 ODSCC TSP AXIAL In Service via APC 4

18 25 H01+.08 DSI 0.47 ODSCC TSP AXIAL In Service via APC 4

18 29 H01+.17 DSI 0.43 ODSCC TSP AXIAL In Service via APC 4

18 32 H03+.08 DSI 0.46 ODSCC TSP AXIAL In Service via APC 4

18 33 H01-.11 DSI 0.64 ODSCC TSP AXIAL In Service via APC 4

18 33 H02+.20 DSI 0.68 ODSCC TSP AXIAL In Service via APC 4

18 33 H05+.03 DSI 0.53 ODSCC TSP AXIAL In Service via APC 4

18 36 H01+.03 DSI 0.49 ODSCC TSP AXIAL In Service via APC 4

18 36 H03+.03 DSI 0.41 ODSCC TSP AXIAL In Service via APC 4

18 38 H03+.06 DSI 0.32 ODSCC TSP AXIAL In Service via APC 4

18 40 H01+.11 DSI 0.51 ODSCC TSP AXIAL In Service via APC 4

18 40 H05+.11 DSI 0.26 ODSCC TSP AXIAL In Service via APC 4

18 41 H01+.00 DSI 0.42 ODSCC TSP AXIAL In Service via APC 4

18 42 H04+.06 DSI 0.37 ODSCC TSP AXIAL In Service via APC 4

18 46 H01+.06 DSI 0.73 ODSCC TSP AXIAL In Service via APC 4

18 48 H01-.06 DSI 0.41 ODSCC TSP AXIAL In Service via APC 4

18 49 H01-.15 DSI 0.93 ODSCC TSP AXIAL In Service via APC 4

18 50 H01-.06 DSI 0.83 ODSCC TSP AXIAL In Service via APC 4

18 51 H05-.03 DSI 0.46 ODSCC TSP AXIAL In Service via APC 4

18 57 H01-.06 DSI 1.05 ODSCC TSP AXIAL In Service via APC 4

18 57 H01+.00 SAI 0.17 ODSCC TSP AXIAL In Service via APC 4

18 57 H02+.00 DSI 0.81 ODSCC TSP AXIAL In Service via APC 4

18 58 H01+.00 DSI 1.25 ODSCC TSP AXIAL In Service via APC 4

18 58 H01+.06 SAI 0.16 ODSCC TSP AXIAL In Service via APC 4

18 58 H01+.25 SAI 0.19 ODSCC TSP AXIAL In Service via APC 4

18 59 H01-.06 DSI 1.05 ODSCC TSP AXIAL In Service via APC 4

18 59 H01+.05 SAI 0.15 ODSCC TSP AXIAL In Service via APC 4

18 59 H01+.10 SAI 0.18 ODSCC TSP AXIAL In Service via APC 4

18 61 H01-.06 DSI 1.06 ODSCC TSP AXIAL In Service via APC 4

18 61 H01+.01 SAI 0.16 ODSCC TSP AXIAL In Service via APC 4

18 62 H01-.06 DSI 1.19 ODSCC TSP AXIAL In Service via APC 4

18 62 H01+.07 SAI 0.15 ODSCC TSP AXIAL In Service via APC 4

18 64 H01+.00 DSI 0.69 ODSCC TSP AXIAL In Service via APC 4

18 67 H01+.17 DSI 0.99 ODSCC TSP AXIAL In Service via APC 4

18 69 H02+.00 DSI 0.65 ODSCC TSP AXIAL In Service via APC 4

19 8

H01+.09 DSI 0.31 ODSCC TSP AXIAL In Service via APC 4

19 12 H01-.03 DSI 0.31 ODSCC TSP AXIAL In Service via APC 4

19 29 H01+.08 DSI 0.56 ODSCC TSP AXIAL In Service via APC 4

19 29 H01+.09 SAI 0.17 ODSCC TSP AXIAL In Service via APC 4

19 34 H01-.11 DSI 0.5 ODSCC TSP AXIAL In Service via APC 4

19 35 H01+.00 DSI 0.64 ODSCC TSP AXIAL In Service via APC 4

19 37 H01+.08 DSI 0.42 ODSCC TSP AXIAL In Service via APC 4

19 42 H01+.11 DSI 0.63 ODSCC TSP AXIAL In Service via APC 4

19 43 H02-.11 DSI 0.95 ODSCC TSP AXIAL In Service via APC 4

19 50 H01-.03 DSI 0.43 ODSCC TSP AXIAL In Service via APC 4

19 51 H01-.09 DSI 1.37 ODSCC TSP AXIAL In Service via APC 4

19 51 H01+.17 SAI 0.24 ODSCC TSP AXIAL In Service via APC 4

19 53 H04-.06 DSI 0.36 ODSCC TSP AXIAL In Service via APC 4

19 56 H01-.03 DSI 0.66 ODSCC TSP AXIAL In Service via APC 4

19 56 H01+.00 SAI 0.14 ODSCC TSP AXIAL In Service via APC 4

19 58 H07+.00 DSI 0.22 ODSCC TSP AXIAL In Service via APC 4

19 63 H01+.03 DSI 1.01 ODSCC TSP AXIAL In Service via APC 4

19 63 H01+.12 SAI 0.2 ODSCC TSP AXIAL In Service via APC 4

19 71 H01-.06 DSI 0.8 ODSCC TSP AXIAL In Service via APC 4

19 72 H02+.20 DSI 0.94 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 66 of 88 4

19 75 H01-.03 DSI 0.97 ODSCC TSP AXIAL In Service via APC 4

19 75 H02-.09 DSI 0.68 ODSCC TSP AXIAL In Service via APC 4

19 76 H02-.03 DSI 0.6 ODSCC TSP AXIAL In Service via APC 4

19 77 H01+.00 DSI 1.12 ODSCC TSP AXIAL In Service via APC 4

19 77 H02-.20 DSI 0.61 ODSCC TSP AXIAL In Service via APC 4

19 84 H01+.00 DSI 1.31 ODSCC TSP AXIAL In Service via APC 4

19 84 H01-.01 SAI 0.19 ODSCC TSP AXIAL In Service via APC 4

19 84 H01+.15 SAI 0.15 ODSCC TSP AXIAL In Service via APC 4

19 87 H03-.18 DSI 0.38 ODSCC TSP AXIAL In Service via APC 4

19 89 H01-.03 DSI 0.78 ODSCC TSP AXIAL In Service via APC 4

19 90 H02+.00 DSI 0.58 ODSCC TSP AXIAL In Service via APC 4

20 12 H02+.11 DSI 0.5 ODSCC TSP AXIAL In Service via APC 4

20 15 H02+.03 DSI 1.59 ODSCC TSP AXIAL In Service via APC 4

20 15 H02+.33 SAI 0.46 ODSCC TSP AXIAL In Service via APC 4

20 17 H06+.09 DSI 0.25 ODSCC TSP AXIAL In Service via APC 4

20 19 H02+.06 DSI 0.26 ODSCC TSP AXIAL In Service via APC 4

20 20 H04+.08 DSI 0.37 ODSCC TSP AXIAL In Service via APC 4

20 25 H01+.09 DSI 1.62 ODSCC TSP AXIAL In Service via APC 4

20 25 H01+.05 SAI 0.19 ODSCC TSP AXIAL In Service via APC 4

20 25 H01+.19 SAI 0.22 ODSCC TSP AXIAL In Service via APC 4

20 25 H01+.26 SAI 0.4 ODSCC TSP AXIAL In Service via APC 4

20 25 H01+.33 SAI 0.35 ODSCC TSP AXIAL In Service via APC 4

20 25 H02+.06 DSI 0.61 ODSCC TSP AXIAL In Service via APC 4

20 26 H02+.06 DSI 0.72 ODSCC TSP AXIAL In Service via APC 4

20 27 H06+.06 DSI 0.54 ODSCC TSP AXIAL In Service via APC 4

20 29 H02+.22 DSI 0.8 ODSCC TSP AXIAL In Service via APC 4

20 29 H04-.03 DSI 0.55 ODSCC TSP AXIAL In Service via APC 4

20 30 H02+.00 DSI 1.63 ODSCC TSP AXIAL In Service via APC 4

20 30 H02+.36 SAI 0.58 ODSCC TSP AXIAL In Service via APC 4

20 30 H02+.37 SAI 0.25 ODSCC TSP AXIAL In Service via APC 4

20 31 H01+.22 DSI 0.67 ODSCC TSP AXIAL In Service via APC 4

20 31 H03+.06 DSI 0.37 ODSCC TSP AXIAL In Service via APC 4

20 31 H05-.08 DSI 0.22 ODSCC TSP AXIAL In Service via APC 4

20 32 H01+.11 DSI 1.19 ODSCC TSP AXIAL In Service via APC 4

20 32 H01+.10 SAI 0.15 ODSCC TSP AXIAL In Service via APC 4

20 32 H01+.15 SAI 0.23 ODSCC TSP AXIAL In Service via APC 4

20 32 H01+.16 SAI 0.3 ODSCC TSP AXIAL In Service via APC 4

20 32 H01+.20 SAI 0.26 ODSCC TSP AXIAL In Service via APC 4

20 34 H01+.14 DSI 0.69 ODSCC TSP AXIAL In Service via APC 4

20 34 H02+.17 DSI 0.87 ODSCC TSP AXIAL In Service via APC 4

20 36 H02-.06 DSI 0.28 ODSCC TSP AXIAL In Service via APC 4

20 37 H01+.06 DSI 1.12 ODSCC TSP AXIAL In Service via APC 4

20 37 H01+.05 SAI 0.17 ODSCC TSP AXIAL In Service via APC 4

20 37 H01+.18 SAI 0.23 ODSCC TSP AXIAL In Service via APC 4

20 37 H01+.26 SAI 0.23 ODSCC TSP AXIAL In Service via APC 4

20 37 H04+.00 DSI 0.37 ODSCC TSP AXIAL In Service via APC 4

20 38 H06+.00 DSI 0.34 ODSCC TSP AXIAL In Service via APC 4

20 39 H01+.17 DSI 1.05 ODSCC TSP AXIAL In Service via APC 4

20 39 H01+.05 SAI 0.15 ODSCC TSP AXIAL In Service via APC 4

20 39 H01+.11 SAI 0.15 ODSCC TSP AXIAL In Service via APC 4

20 39 H01+.30 SAI 0.27 ODSCC TSP AXIAL In Service via APC 4

20 39 H03+.03 DSI 0.39 ODSCC TSP AXIAL In Service via APC 4

20 40 H01+.17 DSI 1.86 ODSCC TSP AXIAL In Service via APC 4

20 40 H01+.28 SAI 0.41 ODSCC TSP AXIAL In Service via APC 4

20 40 H01+.33 SAI 0.77 ODSCC TSP AXIAL In Service via APC 4

20 40 H05+.09 DSI 0.68 ODSCC TSP AXIAL In Service via APC 4

20 44 H02+.08 DSI 0.48 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 67 of 88 4

20 44 H03+.00 DSI 0.77 ODSCC TSP AXIAL In Service via APC 4

20 46 H01+.11 DSI 0.61 ODSCC TSP AXIAL In Service via APC 4

20 46 H02-.14 DSI 1.23 ODSCC TSP AXIAL In Service via APC 4

20 46 H02+.31 DSI 0.87 ODSCC TSP AXIAL In Service via APC 4

20 46 H02+.00 SAI 0.25 ODSCC TSP AXIAL In Service via APC 4

20 46 H02+.16 SAI 0.2 ODSCC TSP AXIAL In Service via APC 4

20 46 H02+.29 SAI 0.28 ODSCC TSP AXIAL In Service via APC 4

20 46 H02+.31 SAI 0.23 ODSCC TSP AXIAL In Service via APC 4

20 46 H03+.08 DSI 0.64 ODSCC TSP AXIAL In Service via APC 4

20 46 H06+.06 DSI 0.49 ODSCC TSP AXIAL In Service via APC 4

20 47 H01+.00 DSI 0.42 ODSCC TSP AXIAL In Service via APC 4

20 47 H02+.06 DSI 0.51 ODSCC TSP AXIAL In Service via APC 4

20 47 H03+.08 DSI 0.39 ODSCC TSP AXIAL In Service via APC 4

20 48 H01+.03 DSI 1.6 ODSCC TSP AXIAL In Service via APC 4

20 48 H01+.02 SAI 0.2 ODSCC TSP AXIAL In Service via APC 4

20 48 H01+.23 SAI 0.47 ODSCC TSP AXIAL In Service via APC 4

20 48 H01+.35 SAI 0.16 ODSCC TSP AXIAL In Service via APC 4

20 48 H02-.23 DSI 0.92 ODSCC TSP AXIAL In Service via APC 4

20 49 H01-.06 DSI 0.43 ODSCC TSP AXIAL In Service via APC 4

20 49 H02-.03 DSI 0.83 ODSCC TSP AXIAL In Service via APC 4

20 49 H02+.14 SAI 0.14 ODSCC TSP AXIAL In Service via APC 4

20 49 H02+.29 SAI 0.19 ODSCC TSP AXIAL In Service via APC 4

20 49 H03+.12 DSI 0.94 ODSCC TSP AXIAL In Service via APC 4

20 50 H01+.09 DSI 1.06 ODSCC TSP AXIAL In Service via APC 4

20 50 H01+.16 SAI 0.18 ODSCC TSP AXIAL In Service via APC 4

20 51 H01+.00 DSI 1.09 ODSCC TSP AXIAL In Service via APC 4

20 51 H01-.04 SAI 0.28 ODSCC TSP AXIAL In Service via APC 4

20 51 H01+.01 SAI 0.14 ODSCC TSP AXIAL In Service via APC 4

20 51 H01+.05 SAI 0.2 ODSCC TSP AXIAL In Service via APC 4

20 51 H03-.03 DSI 0.36 ODSCC TSP AXIAL In Service via APC 4

20 51 H04-.15 DSI 0.41 ODSCC TSP AXIAL In Service via APC 4

20 52 H01-.03 DSI 1.21 ODSCC TSP AXIAL In Service via APC 4

20 52 H01+.18 SAI 0.27 ODSCC TSP AXIAL In Service via APC 4

20 52 H01+.20 SAI 0.34 ODSCC TSP AXIAL In Service via APC 4

20 52 H01+.21 SAI 0.27 ODSCC TSP AXIAL In Service via APC 4

20 53 H02+.03 DSI 0.47 ODSCC TSP AXIAL In Service via APC 4

20 53 H03-.15 DSI 0.52 ODSCC TSP AXIAL In Service via APC 4

20 54 H01+.00 DSI 0.8 ODSCC TSP AXIAL In Service via APC 4

20 55 H02-.18 DSI 0.84 ODSCC TSP AXIAL In Service via APC 4

20 56 H01+.17 DSI 0.83 ODSCC TSP AXIAL In Service via APC 4

20 56 H03-.03 DSI 0.37 ODSCC TSP AXIAL In Service via APC 4

20 57 H01-.12 DSI 0.95 ODSCC TSP AXIAL In Service via APC 4

20 57 H01-.03 SAI 0.23 ODSCC TSP AXIAL In Service via APC 4

20 57 H01-.01 SAI 0.23 ODSCC TSP AXIAL In Service via APC 4

20 57 H01+.23 SAI 0.14 ODSCC TSP AXIAL In Service via APC 4

20 57 H01+.24 SAI 0.23 ODSCC TSP AXIAL In Service via APC 4

20 57 H02+.06 DSI 0.49 ODSCC TSP AXIAL In Service via APC 4

20 58 H01+.03 DSI 1.11 ODSCC TSP AXIAL In Service via APC 4

20 58 H01+.28 SAI 0.46 ODSCC TSP AXIAL In Service via APC 4

20 58 H02+.25 DSI 0.92 ODSCC TSP AXIAL In Service via APC 4

20 58 H06+.00 DSI 0.29 ODSCC TSP AXIAL In Service via APC 4

20 59 H01-.06 DSI 0.7 ODSCC TSP AXIAL In Service via APC 4

20 59 H04+.03 DSI 0.62 ODSCC TSP AXIAL In Service via APC 4

20 59 H05-.06 DSI 0.25 ODSCC TSP AXIAL In Service via APC 4

20 60 H01+.06 DSI 1.49 ODSCC TSP AXIAL In Service via APC 4

20 60 H01-.11 SAI 0.14 ODSCC TSP AXIAL In Service via APC 4

20 60 H01+.20 SAI 0.29 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 68 of 88 4

20 60 H03+.00 DSI 0.53 ODSCC TSP AXIAL In Service via APC 4

20 60 H03+.08 SAI 0.13 ODSCC TSP AXIAL In Service via APC 4

20 61 H01+.00 DSI 0.72 ODSCC TSP AXIAL In Service via APC 4

20 62 H01-.22 DSI 0.58 ODSCC TSP AXIAL In Service via APC 4

20 63 H01-.03 DSI 0.97 ODSCC TSP AXIAL In Service via APC 4

20 64 H01-.03 DSI 0.61 ODSCC TSP AXIAL In Service via APC 4

20 64 H02-.14 DSI 0.94 ODSCC TSP AXIAL In Service via APC 4

20 65 H01-.03 DSI 0.65 ODSCC TSP AXIAL In Service via APC 4

20 66 H02-.03 DSI 0.19 ODSCC TSP AXIAL In Service via APC 4

20 68 H01+.03 DSI 0.85 ODSCC TSP AXIAL In Service via APC 4

20 69 H01-.03 DSI 1.8 ODSCC TSP AXIAL In Service via APC 4

20 69 H01+.22 SAI 0.44 ODSCC TSP AXIAL In Service via APC 4

20 69 H01+.23 SAI 0.27 ODSCC TSP AXIAL In Service via APC 4

20 69 H01+.25 SAI 0.46 ODSCC TSP AXIAL In Service via APC 4

20 69 H02+.00 DSI 0.28 ODSCC TSP AXIAL In Service via APC 4

20 70 H02+.00 DSI 1.15 ODSCC TSP AXIAL In Service via APC 4

20 70 H02+.14 SAI 0.21 ODSCC TSP AXIAL In Service via APC 4

20 70 H02+.23 SAI 0.52 ODSCC TSP AXIAL In Service via APC 4

21 12 H01+.11 DSI 0.52 ODSCC TSP AXIAL In Service via APC 4

21 15 H06+.00 DSI 0.51 ODSCC TSP AXIAL In Service via APC 4

21 19 C05-.03 DSI 0.66 ODSCC TSP AXIAL In Service via APC 4

21 21 H02+.28 DSI 0.98 ODSCC TSP AXIAL In Service via APC 4

21 39 H01+.20 DSI 1.03 ODSCC TSP AXIAL In Service via APC 4

21 39 H01+.18 SAI 0.17 ODSCC TSP AXIAL In Service via APC 4

21 39 H01+.26 SAI 0.4 ODSCC TSP AXIAL In Service via APC 4

21 43 H01+.17 DSI 0.29 ODSCC TSP AXIAL In Service via APC 4

21 44 H01+.08 DSI 0.31 ODSCC TSP AXIAL In Service via APC 4

21 45 H01+.06 DSI 0.7 ODSCC TSP AXIAL In Service via APC 4

21 48 H01-.06 DSI 0.7 ODSCC TSP AXIAL In Service via APC 4

21 48 H02-.23 DSI 1.03 ODSCC TSP AXIAL In Service via APC 4

21 48 H02-.16 SAI 0.24 ODSCC TSP AXIAL In Service via APC 4

21 48 H02-.15 SAI 0.24 ODSCC TSP AXIAL In Service via APC 4

21 48 H03+.00 DSI 0.4 ODSCC TSP AXIAL In Service via APC 4

21 51 H01-.03 DSI 1.01 ODSCC TSP AXIAL In Service via APC 4

21 51 H01+.03 SAI 0.2 ODSCC TSP AXIAL In Service via APC 4

21 51 H01+.27 SAI 0.32 ODSCC TSP AXIAL In Service via APC 4

21 51 H02-.09 DSI 0.74 ODSCC TSP AXIAL In Service via APC 4

21 85 H01+.03 DSI 0.35 ODSCC TSP AXIAL In Service via APC 4

21 87 H01+.06 DSI 0.88 ODSCC TSP AXIAL In Service via APC 4

21 88 H01-.03 DSI 1.02 ODSCC TSP AXIAL In Service via APC 4

21 89 H01-.03 DSI 0.96 ODSCC TSP AXIAL In Service via APC 4

22 8

H02+.12 DSI 0.59 ODSCC TSP AXIAL In Service via APC 4

22 17 C04-.08 DSI 0.47 ODSCC TSP AXIAL In Service via APC 4

22 17 C05-.17 DSI 0.62 ODSCC TSP AXIAL In Service via APC 4

22 17 H06+.11 DSI 0.45 ODSCC TSP AXIAL In Service via APC 4

22 18 H02+.16 DSI 0.8 ODSCC TSP AXIAL In Service via APC 4

22 23 H02+.00 DSI 0.59 ODSCC TSP AXIAL In Service via APC 4

22 24 H03+.08 DSI 0.46 ODSCC TSP AXIAL In Service via APC 4

22 25 H02+.14 DSI 0.78 ODSCC TSP AXIAL In Service via APC 4

22 25 H03+.00 DSI 0.95 ODSCC TSP AXIAL In Service via APC 4

22 33 H01+.17 DSI 1.26 ODSCC TSP AXIAL In Service via APC 4

22 33 H01-.07 SAI 0.23 ODSCC TSP AXIAL In Service via APC 4

22 33 H01+.28 SAI 0.43 ODSCC TSP AXIAL In Service via APC 4

22 33 H02-.11 DSI 1.58 ODSCC TSP AXIAL In Service via APC 4

22 33 H02+.36 SAI 0.43 ODSCC TSP AXIAL In Service via APC 4

22 37 H02+.06 DSI 0.41 ODSCC TSP AXIAL In Service via APC 4

22 41 H01+.14 DSI 1.21 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 69 of 88 4

22 41 H01+.16 SAI 0.14 ODSCC TSP AXIAL In Service via APC 4

22 41 H01+.23 SAI 0.28 ODSCC TSP AXIAL In Service via APC 4

22 41 H02-.14 DSI 1.1 ODSCC TSP AXIAL In Service via APC 4

22 41 H02+.23 SAI 0.21 ODSCC TSP AXIAL In Service via APC 4

22 41 H02+.35 SAI 0.28 ODSCC TSP AXIAL In Service via APC 4

22 41 H02+.37 SAI 0.33 ODSCC TSP AXIAL In Service via APC 4

22 41 H04+.08 DSI 0.48 ODSCC TSP AXIAL In Service via APC 4

22 45 H01+.00 DSI 0.37 ODSCC TSP AXIAL In Service via APC 4

22 46 H01+.00 DSI 0.46 ODSCC TSP AXIAL In Service via APC 4

22 46 H02+.06 DSI 0.62 ODSCC TSP AXIAL In Service via APC 4

22 46 H03+.03 DSI 0.64 ODSCC TSP AXIAL In Service via APC 4

22 47 H02+.22 DSI 1.09 ODSCC TSP AXIAL In Service via APC 4

22 47 H02+.19 SAI 0.18 ODSCC TSP AXIAL In Service via APC 4

22 47 H02+.34 SAI 0.74 ODSCC TSP AXIAL In Service via APC 4

22 59 H01-.15 DSI 0.85 ODSCC TSP AXIAL In Service via APC 4

22 59 H02+.00 DSI 0.73 ODSCC TSP AXIAL In Service via APC 4

22 65 H01-.17 DSI 0.91 ODSCC TSP AXIAL In Service via APC 4

22 67 H02+.00 DSI 0.71 ODSCC TSP AXIAL In Service via APC 4

22 67 H02-.08 SAI 0.12 ODSCC TSP AXIAL In Service via APC 4

22 68 H01-.11 DSI 0.93 ODSCC TSP AXIAL In Service via APC 4

22 70 H01-.06 DSI 4.74 ODSCC TSP AXIAL PULL/PLUGGED 4

22 70 H01-.05 SAI 0.54 ODSCC TSP AXIAL PULL/PLUGGED 4

22 70 H01+.02 SAI 0.23 ODSCC TSP AXIAL PULL/PLUGGED 4

22 70 H01+.09 SAI 0.43 ODSCC TSP AXIAL PULL/PLUGGED 4

22 70 H01+.24 SAI 1.98 ODSCC TSP AXIAL PULL/PLUGGED 4

22 70 H01+.27 SAI 1.82 ODSCC TSP AXIAL PULL/PLUGGED 4

22 70 H01+.32 SAI 0.28 ODSCC TSP AXIAL PULL/PLUGGED 4

22 70 H02-.11 DSI 0.66 ODSCC TSP AXIAL PULL/PLUGGED 4

22 70 H02+.17 SAI 0.09 ODSCC TSP AXIAL PULL/PLUGGED 4

22 70 H02+.33 SAI 0.24 ODSCC TSP AXIAL PULL/PLUGGED 4

22 70 H03+.14 DSI 0.4 ODSCC TSP AXIAL PLUGGED 4

22 70 H03+.18 SAI 0.14 ODSCC TSP AXIAL PLUGGED 4

22 71 H03+.00 DSI 0.7 ODSCC TSP AXIAL In Service via APC 4

23 12 H01+.11 DSI 0.71 ODSCC TSP AXIAL In Service via APC 4

23 12 H01+.22 SAI 0.19 ODSCC TSP AXIAL In Service via APC 4

23 14 C05+.00 DSI 0.66 ODSCC TSP AXIAL In Service via APC 4

23 40 H01+.03 DSI 0.28 ODSCC TSP AXIAL In Service via APC 4

23 41 H01+.14 DSI 0.48 ODSCC TSP AXIAL In Service via APC 4

23 42 H01+.08 DSI 0.46 ODSCC TSP AXIAL In Service via APC 4

23 43 H02+.03 DSI 0.35 ODSCC TSP AXIAL In Service via APC 4

23 44 H03+.06 DSI 0.4 ODSCC TSP AXIAL In Service via APC 4

23 45 H01+.06 DSI 0.52 ODSCC TSP AXIAL In Service via APC 4

23 45 H03+.11 DSI 0.36 ODSCC TSP AXIAL In Service via APC 4

23 54 H01+.03 DSI 1.75 ODSCC TSP AXIAL In Service via APC 4

23 54 H01+.08 SAI 0.18 ODSCC TSP AXIAL In Service via APC 4

23 54 H01+.23 SAI 0.15 ODSCC TSP AXIAL In Service via APC 4

23 54 H02-.09 DSI 0.62 ODSCC TSP AXIAL In Service via APC 4

23 56 H02-.17 DSI 0.52 ODSCC TSP AXIAL In Service via APC 4

23 60 H01+.00 DSI 1.11 ODSCC TSP AXIAL In Service via APC 4

23 60 H01+.16 SAI 0.19 ODSCC TSP AXIAL In Service via APC 4

23 60 H01+.25 SAI 0.14 ODSCC TSP AXIAL In Service via APC 4

23 60 H01+.34 SAI 0.1 ODSCC TSP AXIAL In Service via APC 4

23 60 H02+.03 DSI 0.74 ODSCC TSP AXIAL In Service via APC 4

23 61 H02+.03 DSI 0.34 ODSCC TSP AXIAL In Service via APC 4

23 63 H01-.20 DSI 1.26 ODSCC TSP AXIAL In Service via APC 4

23 63 H01-.04 SAI 0.31 ODSCC TSP AXIAL In Service via APC 4

23 63 H01+.27 SAI 0.21 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 70 of 88 4

23 63 H01+.33 SAI 0.48 ODSCC TSP AXIAL In Service via APC 4

23 63 H02-.06 DSI 0.32 ODSCC TSP AXIAL In Service via APC 4

23 64 H01-.06 DSI 1.05 ODSCC TSP AXIAL In Service via APC 4

23 64 H01+.05 SAI 0.23 ODSCC TSP AXIAL In Service via APC 4

23 64 H01+.08 SAI 0.31 ODSCC TSP AXIAL In Service via APC 4

23 64 H01+.21 SAI 0.46 ODSCC TSP AXIAL In Service via APC 4

23 65 H02-.03 DSI 1.08 ODSCC TSP AXIAL In Service via APC 4

23 65 H02+.13 SAI 0.39 ODSCC TSP AXIAL In Service via APC 4

23 65 H02+.27 SAI 0.36 ODSCC TSP AXIAL In Service via APC 4

23 66 H01+.00 DSI 1.06 ODSCC TSP AXIAL In Service via APC 4

23 66 H01+.04 SAI 0.2 ODSCC TSP AXIAL In Service via APC 4

23 66 H01+.28 SAI 0.65 ODSCC TSP AXIAL In Service via APC 4

23 66 H02-.20 DSI 0.66 ODSCC TSP AXIAL In Service via APC 4

23 67 H02-.06 DSI 0.68 ODSCC TSP AXIAL In Service via APC 4

23 68 H01+.06 DSI 0.78 ODSCC TSP AXIAL In Service via APC 4

23 69 H01+.12 DSI 0.78 ODSCC TSP AXIAL In Service via APC 4

23 69 H02+.18 DSI 0.7 ODSCC TSP AXIAL In Service via APC 4

23 70 H01-.03 DSI 1.27 ODSCC TSP AXIAL In Service via APC 4

23 70 H01+.21 SAI 0.63 ODSCC TSP AXIAL In Service via APC 4

23 70 H02+.00 DSI 0.77 ODSCC TSP AXIAL In Service via APC 4

23 71 H01-.03 DSI 0.84 ODSCC TSP AXIAL In Service via APC 4

23 71 H02-.09 DSI 0.78 ODSCC TSP AXIAL In Service via APC 4

23 72 H01+.00 DSI 1.02 ODSCC TSP AXIAL In Service via APC 4

23 72 H01-.18 SAI 0.23 ODSCC TSP AXIAL In Service via APC 4

23 72 H01+.23 SAI 0.15 ODSCC TSP AXIAL In Service via APC 4

23 73 H01+.15 DSI 0.93 ODSCC TSP AXIAL In Service via APC 4

23 73 H02-.09 DSI 1.1 ODSCC TSP AXIAL In Service via APC 4

23 73 H02+.34 SAI 0.66 ODSCC TSP AXIAL In Service via APC 4

23 73 H06+.00 DSI 0.34 ODSCC TSP AXIAL In Service via APC 4

23 74 H01+.00 DSI 0.97 ODSCC TSP AXIAL In Service via APC 4

23 75 H01-.03 DSI 1.1 ODSCC TSP AXIAL In Service via APC 4

23 75 H01+.02 SAI 0.2 ODSCC TSP AXIAL In Service via APC 4

23 75 H02-.18 DSI 0.86 ODSCC TSP AXIAL In Service via APC 4

23 75 H03-.06 DSI 1.1 ODSCC TSP AXIAL In Service via APC 4

23 86 H01+.00 DSI 0.83 ODSCC TSP AXIAL In Service via APC 4

23 86 H03+.00 DSI 0.54 ODSCC TSP AXIAL In Service via APC 4

23 87 H01-.06 DSI 1.69 ODSCC TSP AXIAL In Service via APC 4

23 87 H01+.13 SAI 0.26 ODSCC TSP AXIAL In Service via APC 4

24 15 C05+.00 DSI 0.47 ODSCC TSP AXIAL In Service via APC 4

24 46 H01+.08 DSI 0.78 ODSCC TSP AXIAL In Service via APC 4

24 52 H02+.20 DSI 0.69 ODSCC TSP AXIAL In Service via APC 4

24 62 H02-.03 DSI 0.46 ODSCC TSP AXIAL In Service via APC 4

25 21 H01-.03 DSI 0.75 ODSCC TSP AXIAL In Service via APC 4

25 22 H02+.11 DSI 0.77 ODSCC TSP AXIAL In Service via APC 4

25 40 H01+.03 DSI 1.92 ODSCC TSP AXIAL In Service via APC 4

25 40 H01+.25 SAI 0.59 ODSCC TSP AXIAL In Service via APC 4

25 40 H01+.26 SAI 0.27 ODSCC TSP AXIAL In Service via APC 4

25 40 H02-.03 DSI 0.74 ODSCC TSP AXIAL In Service via APC 4

25 41 H01+.14 DSI 1.01 ODSCC TSP AXIAL In Service via APC 4

25 41 H01+.26 SAI 0.15 ODSCC TSP AXIAL In Service via APC 4

25 41 H02+.14 DSI 0.4 ODSCC TSP AXIAL In Service via APC 4

25 42 H01-.03 DSI 1.62 ODSCC TSP AXIAL In Service via APC 4

25 42 H01+.34 SAI 0.39 ODSCC TSP AXIAL In Service via APC 4

25 43 H01+.08 DSI 1.26 ODSCC TSP AXIAL In Service via APC 4

25 43 H01+.24 SAI 0.29 ODSCC TSP AXIAL In Service via APC 4

25 46 C05-.03 DSI 0.34 ODSCC TSP AXIAL In Service via APC 4

25 47 H05+.03 DSI 0.23 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 71 of 88 4

25 49 H02-.06 DSI 1.45 ODSCC TSP AXIAL In Service via APC 4

25 49 H02+.26 SAI 0.27 ODSCC TSP AXIAL In Service via APC 4

25 49 H02+.33 SAI 0.35 ODSCC TSP AXIAL In Service via APC 4

25 51 H01-.03 DSI 0.74 ODSCC TSP AXIAL In Service via APC 4

25 53 H01-.15 DSI 1.1 ODSCC TSP AXIAL In Service via APC 4

25 53 H01-.05 SAI 0.39 ODSCC TSP AXIAL In Service via APC 4

25 53 H01+.21 SAI 0.23 ODSCC TSP AXIAL In Service via APC 4

25 53 H01+.33 SAI 0.3 ODSCC TSP AXIAL In Service via APC 4

25 53 H02+.00 DSI 0.44 ODSCC TSP AXIAL In Service via APC 4

25 57 H01-.15 DSI 1.02 ODSCC TSP AXIAL In Service via APC 4

25 57 H01-.01 SAI 0.24 ODSCC TSP AXIAL In Service via APC 4

25 57 H02-.06 DSI 0.87 ODSCC TSP AXIAL In Service via APC 4

25 57 H04-.15 DSI 0.45 ODSCC TSP AXIAL In Service via APC 4

25 58 H01-.03 DSI 0.71 ODSCC TSP AXIAL In Service via APC 4

25 58 H02+.20 DSI 0.9 ODSCC TSP AXIAL In Service via APC 4

25 59 H01-.06 DSI 0.46 ODSCC TSP AXIAL In Service via APC 4

25 60 H01-.14 DSI 1.11 ODSCC TSP AXIAL In Service via APC 4

25 60 H01+.30 SAI 0.12 ODSCC TSP AXIAL In Service via APC 4

25 60 H01+.33 SAI 0.39 ODSCC TSP AXIAL In Service via APC 4

25 60 H02-.11 DSI 0.41 ODSCC TSP AXIAL In Service via APC 4

25 67 H04-.09 DSI 0.38 ODSCC TSP AXIAL In Service via APC 4

25 75 H02-.15 DSI 0.64 ODSCC TSP AXIAL In Service via APC 4

25 75 H05+.00 DSI 0.47 ODSCC TSP AXIAL In Service via APC 4

25 80 H01+.00 DSI 0.69 ODSCC TSP AXIAL In Service via APC 4

25 80 H01+.13 SAI 0.18 ODSCC TSP AXIAL In Service via APC 4

25 80 H02-.06 DSI 1.07 ODSCC TSP AXIAL In Service via APC 4

25 83 H01+.00 DSI 0.79 ODSCC TSP AXIAL In Service via APC 4

25 85 H01+.00 DSI 0.55 ODSCC TSP AXIAL In Service via APC 4

26 14 H02-.17 DSI 0.83 ODSCC TSP AXIAL In Service via APC 4

26 14 H03+.17 DSI 0.79 ODSCC TSP AXIAL In Service via APC 4

26 19 H02+.19 DSI 0.96 ODSCC TSP AXIAL In Service via APC 4

26 19 H03+.16 DSI 0.68 ODSCC TSP AXIAL In Service via APC 4

26 20 H02+.00 DSI 0.47 ODSCC TSP AXIAL In Service via APC 4

26 20 H04+.11 DSI 0.43 ODSCC TSP AXIAL In Service via APC 4

26 21 H03+.11 DSI 0.42 ODSCC TSP AXIAL In Service via APC 4

26 24 H02+.17 DSI 0.51 ODSCC TSP AXIAL In Service via APC 4

26 27 H03+.09 DSI 0.45 ODSCC TSP AXIAL In Service via APC 4

26 27 H04+.03 DSI 0.4 ODSCC TSP AXIAL In Service via APC 4

26 27 H06+.03 DSI 0.34 ODSCC TSP AXIAL In Service via APC 4

26 29 H02+.14 DSI 0.49 ODSCC TSP AXIAL In Service via APC 4

26 31 H03+.08 DSI 0.48 ODSCC TSP AXIAL In Service via APC 4

26 31 H06+.00 DSI 0.24 ODSCC TSP AXIAL In Service via APC 4

26 33 H02-.18 DSI 0.85 ODSCC TSP AXIAL In Service via APC 4

26 35 H01+.14 DSI 0.92 ODSCC TSP AXIAL In Service via APC 4

26 36 H01-.08 DSI 0.74 ODSCC TSP AXIAL In Service via APC 4

26 47 H03+.06 DSI 0.19 ODSCC TSP AXIAL In Service via APC 4

26 48 H01-.06 DSI 0.35 ODSCC TSP AXIAL In Service via APC 4

26 51 H01-.03 DSI 0.47 ODSCC TSP AXIAL In Service via APC 4

26 57 H07+.00 DSI 0.21 ODSCC TSP AXIAL In Service via APC 4

26 62 H01+.00 DSI 0.69 ODSCC TSP AXIAL In Service via APC 4

26 64 H01-.14 DSI 0.49 ODSCC TSP AXIAL In Service via APC 4

26 65 H02+.00 DSI 0.83 ODSCC TSP AXIAL In Service via APC 4

26 66 H02+.00 DSI 0.69 ODSCC TSP AXIAL In Service via APC 4

26 68 H01+.06 DSI 1.5 ODSCC TSP AXIAL In Service via APC 4

26 68 H01+.25 SAI 0.31 ODSCC TSP AXIAL In Service via APC 4

26 68 H01+.33 SAI 0.53 ODSCC TSP AXIAL In Service via APC 4

26 69 H01+.00 DSI 1.01 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 72 of 88 4

26 69 H01+.19 SAI 0.23 ODSCC TSP AXIAL In Service via APC 4

26 71 H01+.03 DSI 0.71 ODSCC TSP AXIAL In Service via APC 4

26 71 H03+.00 DSI 0.44 ODSCC TSP AXIAL In Service via APC 4

26 72 H01-.06 DSI 0.53 ODSCC TSP AXIAL In Service via APC 4

26 73 H02-.15 DSI 1.26 ODSCC TSP AXIAL In Service via APC 4

26 73 H02-.12 SAI 0.07 ODSCC TSP AXIAL In Service via APC 4

26 73 H02-.02 SAI 0.17 ODSCC TSP AXIAL In Service via APC 4

26 73 H02+.20 SAI 0.24 ODSCC TSP AXIAL In Service via APC 4

26 83 H02+.00 DSI 0.73 ODSCC TSP AXIAL In Service via APC 4

26 85 H01-.03 DSI 0.63 ODSCC TSP AXIAL In Service via APC 4

27 14 H02+.20 DSI 0.72 ODSCC TSP AXIAL In Service via APC 4

27 14 H02+.21 SAI 0.17 ODSCC TSP AXIAL In Service via APC 4

27 15 H02+.11 DSI 1.18 ODSCC TSP AXIAL In Service via APC 4

27 15 H02+.26 SAI 0.28 ODSCC TSP AXIAL In Service via APC 4

27 17 H02+.08 DSI 0.45 ODSCC TSP AXIAL In Service via APC 4

27 18 H02+.05 DSI 0.51 ODSCC TSP AXIAL In Service via APC 4

27 20 H01+.00 DSI 0.46 ODSCC TSP AXIAL In Service via APC 4

27 21 H03+.08 DSI 0.49 ODSCC TSP AXIAL In Service via APC 4

27 22 H04+.00 DSI 0.37 ODSCC TSP AXIAL In Service via APC 4

27 27 H02+.17 DSI 0.91 ODSCC TSP AXIAL In Service via APC 4

27 45 H01+.17 DSI 0.95 ODSCC TSP AXIAL In Service via APC 4

27 46 H01+.08 DSI 0.91 ODSCC TSP AXIAL In Service via APC 4

27 48 H01-.03 DSI 0.99 ODSCC TSP AXIAL In Service via APC 4

27 51 H02+.03 DSI 0.48 ODSCC TSP AXIAL In Service via APC 4

27 53 H01+.00 DSI 0.49 ODSCC TSP AXIAL In Service via APC 4

27 55 H01+.00 DSI 0.5 ODSCC TSP AXIAL In Service via APC 4

27 61 H01+.00 DSI 0.14 ODSCC TSP AXIAL In Service via APC 4

27 62 H01+.00 DSI 0.6 ODSCC TSP AXIAL In Service via APC 4

27 63 H01-.09 DSI 0.99 ODSCC TSP AXIAL In Service via APC 4

27 63 H02-.06 DSI 0.95 ODSCC TSP AXIAL In Service via APC 4

27 63 H03-.06 DSI 0.34 ODSCC TSP AXIAL In Service via APC 4

27 65 H01-.18 DSI 0.58 ODSCC TSP AXIAL In Service via APC 4

27 65 H02-.12 DSI 0.5 ODSCC TSP AXIAL In Service via APC 4

27 65 H03-.06 DSI 0.38 ODSCC TSP AXIAL In Service via APC 4

27 66 H02+.06 DSI 0.58 ODSCC TSP AXIAL In Service via APC 4

27 66 H04+.00 DSI 0.33 ODSCC TSP AXIAL In Service via APC 4

27 67 H02-.09 DSI 0.51 ODSCC TSP AXIAL In Service via APC 4

27 69 H01+.03 DSI 0.81 ODSCC TSP AXIAL In Service via APC 4

27 71 H01+.00 DSI 1.7 ODSCC TSP AXIAL In Service via APC 4

27 71 H01+.04 SAI 0.3 ODSCC TSP AXIAL In Service via APC 4

27 71 H01+.14 SAI 0.31 ODSCC TSP AXIAL In Service via APC 4

27 71 H01+.21 SAI 0.54 ODSCC TSP AXIAL In Service via APC 4

27 72 H02-.11 DSI 0.58 ODSCC TSP AXIAL In Service via APC 4

27 72 H03+.00 DSI 0.69 ODSCC TSP AXIAL In Service via APC 4

27 73 H02+.12 DSI 1.99 ODSCC TSP AXIAL In Service via APC 4

27 73 H02+.08 SAI 0.47 ODSCC TSP AXIAL In Service via APC 4

27 73 H02+.37 SAI 0.41 ODSCC TSP AXIAL In Service via APC 4

27 73 H03-.09 DSI 0.77 ODSCC TSP AXIAL In Service via APC 4

27 74 C05+.06 DSI 0.23 ODSCC TSP AXIAL In Service via APC 4

27 74 H01+.00 DSI 1.13 ODSCC TSP AXIAL In Service via APC 4

27 74 H01+.06 SAI 0.19 ODSCC TSP AXIAL In Service via APC 4

27 74 H01+.19 SAI 0.32 ODSCC TSP AXIAL In Service via APC 4

27 74 H02-.03 DSI 0.97 ODSCC TSP AXIAL In Service via APC 4

27 74 H03+.00 DSI 0.32 ODSCC TSP AXIAL In Service via APC 4

27 75 H01+.03 DSI 1.27 ODSCC TSP AXIAL In Service via APC 4

27 75 H01+.11 SAI 0.15 ODSCC TSP AXIAL In Service via APC 4

27 75 H01+.21 SAI 0.11 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 73 of 88 4

27 75 H01+.22 SAI 0.2 ODSCC TSP AXIAL In Service via APC 4

27 75 H02+.09 DSI 0.84 ODSCC TSP AXIAL In Service via APC 4

27 75 H03-.06 DSI 0.59 ODSCC TSP AXIAL In Service via APC 4

27 76 H01-.17 DSI 1.46 ODSCC TSP AXIAL In Service via APC 4

27 76 H02+.00 DSI 0.31 ODSCC TSP AXIAL In Service via APC 4

27 76 H05-.14 DSI 0.5 ODSCC TSP AXIAL In Service via APC 4

27 77 H01-.03 DSI 0.99 ODSCC TSP AXIAL In Service via APC 4

27 77 H02+.00 DSI 0.72 ODSCC TSP AXIAL In Service via APC 4

27 77 H03+.06 DSI 1.01 ODSCC TSP AXIAL In Service via APC 4

27 77 H03-.03 SAI 0.13 ODSCC TSP AXIAL In Service via APC 4

27 77 H03+.17 SAI 0.21 ODSCC TSP AXIAL In Service via APC 4

27 77 H03+.18 SAI 0.11 ODSCC TSP AXIAL In Service via APC 4

27 77 H03+.24 SAI 0.21 ODSCC TSP AXIAL In Service via APC 4

27 77 H03+.27 SAI 0.15 ODSCC TSP AXIAL In Service via APC 4

27 77 H04+.03 DSI 0.6 ODSCC TSP AXIAL In Service via APC 4

27 78 H01+.03 DSI 0.81 ODSCC TSP AXIAL In Service via APC 4

27 78 H02+.11 DSI 1.13 ODSCC TSP AXIAL In Service via APC 4

27 78 H02+.29 SAI 0.52 ODSCC TSP AXIAL In Service via APC 4

27 79 H01+.00 DSI 1.27 ODSCC TSP AXIAL In Service via APC 4

27 79 H01-.06 SAI 0.13 ODSCC TSP AXIAL In Service via APC 4

27 79 H02+.00 DSI 1.01 ODSCC TSP AXIAL In Service via APC 4

27 79 H02+.02 SAI 0.15 ODSCC TSP AXIAL In Service via APC 4

27 79 H02+.12 SAI 0.18 ODSCC TSP AXIAL In Service via APC 4

27 80 H02-.06 DSI 0.66 ODSCC TSP AXIAL In Service via APC 4

27 80 H03-.03 DSI 0.99 ODSCC TSP AXIAL In Service via APC 4

27 81 H02-.06 DSI 1.28 ODSCC TSP AXIAL In Service via APC 4

27 81 H03-.03 DSI 0.91 ODSCC TSP AXIAL In Service via APC 4

27 82 H03-.06 DSI 0.9 ODSCC TSP AXIAL In Service via APC 4

27 82 H05+.03 DSI 0.88 ODSCC TSP AXIAL In Service via APC 4

27 83 H02-.03 DSI 0.88 ODSCC TSP AXIAL In Service via APC 4

27 83 H03-.09 DSI 0.87 ODSCC TSP AXIAL In Service via APC 4

27 83 H04+.00 DSI 0.49 ODSCC TSP AXIAL In Service via APC 4

27 84 H01-.11 DSI 0.31 ODSCC TSP AXIAL In Service via APC 4

27 84 H02+.03 DSI 1.17 ODSCC TSP AXIAL In Service via APC 4

27 84 H02+.04 SAI 0.12 ODSCC TSP AXIAL In Service via APC 4

27 85 H05+.03 DSI 0.59 ODSCC TSP AXIAL In Service via APC 4

28 15 C07-.06 DSI 0.44 ODSCC TSP AXIAL In Service via APC 4

28 20 H01+.03 DSI 0.51 ODSCC TSP AXIAL In Service via APC 4

28 24 H04-.14 DSI 0.64 ODSCC TSP AXIAL In Service via APC 4

28 24 H06+.00 DSI 0.22 ODSCC TSP AXIAL In Service via APC 4

28 28 H04+.00 DSI 0.63 ODSCC TSP AXIAL In Service via APC 4

28 33 H03+.00 DSI 0.37 ODSCC TSP AXIAL In Service via APC 4

28 35 H02+.14 DSI 1.15 ODSCC TSP AXIAL In Service via APC 4

28 35 H02+.29 SAI 0.22 ODSCC TSP AXIAL In Service via APC 4

28 35 H02+.30 SAI 0.25 ODSCC TSP AXIAL In Service via APC 4

28 40 H02+.11 DSI 0.47 ODSCC TSP AXIAL In Service via APC 4

28 45 H01+.08 DSI 0.58 ODSCC TSP AXIAL In Service via APC 4

28 47 H02+.11 DSI 0.46 ODSCC TSP AXIAL In Service via APC 4

28 48 H01-.03 DSI 1.22 ODSCC TSP AXIAL In Service via APC 4

28 48 H01-.12 SAI 0.19 ODSCC TSP AXIAL In Service via APC 4

28 48 H01+.07 SAI 0.13 ODSCC TSP AXIAL In Service via APC 4

28 48 H01+.22 SAI 0.24 ODSCC TSP AXIAL In Service via APC 4

28 48 H01+.33 SAI 0.34 ODSCC TSP AXIAL In Service via APC 4

28 48 H03-.03 DSI 0.79 ODSCC TSP AXIAL In Service via APC 4

28 52 H02+.11 DSI 0.36 ODSCC TSP AXIAL In Service via APC 4

28 62 H02+.00 DSI 0.65 ODSCC TSP AXIAL In Service via APC 4

28 63 H01+.03 DSI 0.73 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 74 of 88 4

28 63 H02+.00 DSI 0.76 ODSCC TSP AXIAL In Service via APC 4

28 63 H03+.00 DSI 0.61 ODSCC TSP AXIAL In Service via APC 4

28 64 H02-.06 DSI 0.66 ODSCC TSP AXIAL In Service via APC 4

28 65 H01-.09 DSI 0.97 ODSCC TSP AXIAL In Service via APC 4

28 66 H02-.06 DSI 0.89 ODSCC TSP AXIAL In Service via APC 4

28 66 H03-.19 DSI 0.59 ODSCC TSP AXIAL In Service via APC 4

28 67 H01+.03 DSI 1.59 ODSCC TSP AXIAL In Service via APC 4

28 67 H01+.15 SAI 0.19 ODSCC TSP AXIAL In Service via APC 4

28 67 H01+.19 SAI 0.21 ODSCC TSP AXIAL In Service via APC 4

28 67 H01+.22 SAI 0.11 ODSCC TSP AXIAL In Service via APC 4

28 68 H01-.17 DSI 1.02 ODSCC TSP AXIAL In Service via APC 4

28 68 H01+.03 SAI 0.15 ODSCC TSP AXIAL In Service via APC 4

28 68 H01+.20 SAI 0.33 ODSCC TSP AXIAL In Service via APC 4

28 68 H02+.00 DSI 0.5 ODSCC TSP AXIAL In Service via APC 4

28 68 H05-.08 DSI 0.59 ODSCC TSP AXIAL In Service via APC 4

28 70 H01+.03 DSI 0.56 ODSCC TSP AXIAL In Service via APC 4

28 70 H02+.17 DSI 0.82 ODSCC TSP AXIAL In Service via APC 4

28 71 H01-.09 DSI 1.02 ODSCC TSP AXIAL In Service via APC 4

28 71 H01+.14 SAI 0.21 ODSCC TSP AXIAL In Service via APC 4

28 71 H01+.20 SAI 0.12 ODSCC TSP AXIAL In Service via APC 4

28 71 H02-.03 DSI 1.27 ODSCC TSP AXIAL In Service via APC 4

28 71 H02-.03 SAI 0.18 ODSCC TSP AXIAL In Service via APC 4

28 71 H02+.18 SAI 0.14 ODSCC TSP AXIAL In Service via APC 4

28 71 H02+.28 SAI 0.16 ODSCC TSP AXIAL In Service via APC 4

28 72 H01+.00 DSI 1.06 ODSCC TSP AXIAL In Service via APC 4

28 72 H01+.09 SAI 0.19 ODSCC TSP AXIAL In Service via APC 4

28 72 H01+.24 SAI 0.16 ODSCC TSP AXIAL In Service via APC 4

28 72 H02+.14 DSI 0.98 ODSCC TSP AXIAL In Service via APC 4

28 72 H03+.00 DSI 0.71 ODSCC TSP AXIAL In Service via APC 4

28 73 H01-.12 DSI 0.85 ODSCC TSP AXIAL In Service via APC 4

28 74 H02+.00 DSI 0.36 ODSCC TSP AXIAL In Service via APC 4

28 74 H03+.11 DSI 1.16 ODSCC TSP AXIAL In Service via APC 4

28 74 H03+.06 SAI 0.23 ODSCC TSP AXIAL In Service via APC 4

28 74 H03+.34 SAI 0.44 ODSCC TSP AXIAL In Service via APC 4

28 74 H05-.03 DSI 0.69 ODSCC TSP AXIAL In Service via APC 4

28 75 H01-.03 DSI 1.08 ODSCC TSP AXIAL In Service via APC 4

28 75 H01+.02 SAI 0.21 ODSCC TSP AXIAL In Service via APC 4

28 75 H02+.09 DSI 1.08 ODSCC TSP AXIAL In Service via APC 4

28 75 H02+.15 SAI 0.26 ODSCC TSP AXIAL In Service via APC 4

28 75 H02+.21 SAI 0.2 ODSCC TSP AXIAL In Service via APC 4

28 75 H02+.33 SAI 0.19 ODSCC TSP AXIAL In Service via APC 4

28 76 H01-.06 DSI 0.39 ODSCC TSP AXIAL In Service via APC 4

28 76 H02+.06 DSI 0.49 ODSCC TSP AXIAL In Service via APC 4

28 77 H01-.03 DSI 1.05 ODSCC TSP AXIAL In Service via APC 4

28 77 H01+.07 SAI 0.22 ODSCC TSP AXIAL In Service via APC 4

28 77 H01+.15 SAI 0.15 ODSCC TSP AXIAL In Service via APC 4

28 77 H02-.03 DSI 0.52 ODSCC TSP AXIAL In Service via APC 4

28 78 H01+.00 DSI 0.93 ODSCC TSP AXIAL In Service via APC 4

28 78 H02+.06 DSI 0.45 ODSCC TSP AXIAL In Service via APC 4

28 79 H02+.00 DSI 0.95 ODSCC TSP AXIAL In Service via APC 4

28 79 H03+.03 DSI 0.52 ODSCC TSP AXIAL In Service via APC 4

28 79 H04-.09 DSI 0.59 ODSCC TSP AXIAL In Service via APC 4

28 80 H02+.11 DSI 0.56 ODSCC TSP AXIAL In Service via APC 4

28 80 H03-.03 DSI 0.89 ODSCC TSP AXIAL In Service via APC 4

28 81 H01-.03 DSI 0.39 ODSCC TSP AXIAL In Service via APC 4

28 81 H02-.03 DSI 0.94 ODSCC TSP AXIAL In Service via APC 4

28 81 H03-.03 DSI 0.76 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 75 of 88 4

28 81 H05+.06 DSI 0.52 ODSCC TSP AXIAL In Service via APC 4

28 82 H02+.06 DSI 1.06 ODSCC TSP AXIAL In Service via APC 4

28 82 H02+.27 SAI 0.16 ODSCC TSP AXIAL In Service via APC 4

28 83 H02-.03 DSI 0.9 ODSCC TSP AXIAL In Service via APC 4

28 84 H01-.06 DSI 0.38 ODSCC TSP AXIAL In Service via APC 4

29 14 H01-.03 DSI 0.37 ODSCC TSP AXIAL In Service via APC 4

29 18 H07+.03 DSI 0.96 ODSCC TSP AXIAL In Service via APC 4

29 19 H06+.17 DSI 0.47 ODSCC TSP AXIAL In Service via APC 4

29 27 H02+.00 DSI 0.5 ODSCC TSP AXIAL In Service via APC 4

29 27 H07+.03 DSI 0.31 ODSCC TSP AXIAL In Service via APC 4

29 28 H02+.03 DSI 0.53 ODSCC TSP AXIAL In Service via APC 4

29 30 H02-.06 DSI 1.39 ODSCC TSP AXIAL In Service via APC 4

29 30 H02+.14 SAI 0.59 ODSCC TSP AXIAL In Service via APC 4

29 30 H02+.37 SAI 0.35 ODSCC TSP AXIAL In Service via APC 4

29 35 H01+.11 DSI 0.48 ODSCC TSP AXIAL In Service via APC 4

29 35 H02+.06 DSI 0.31 ODSCC TSP AXIAL In Service via APC 4

29 38 H01+.08 DSI 0.68 ODSCC TSP AXIAL In Service via APC 4

29 38 H02+.08 DSI 0.48 ODSCC TSP AXIAL In Service via APC 4

29 42 H02-.03 DSI 0.96 ODSCC TSP AXIAL In Service via APC 4

29 43 H01+.17 DSI 0.88 ODSCC TSP AXIAL In Service via APC 4

29 46 H02+.06 DSI 0.29 ODSCC TSP AXIAL In Service via APC 4

29 47 H01+.17 DSI 0.78 ODSCC TSP AXIAL In Service via APC 4

29 48 C06+.03 DSI 0.39 ODSCC TSP AXIAL In Service via APC 4

29 48 H01+.00 DSI 1.04 ODSCC TSP AXIAL In Service via APC 4

29 48 H01+.13 SAI 0.15 ODSCC TSP AXIAL In Service via APC 4

29 50 H01-.03 DSI 0.78 ODSCC TSP AXIAL In Service via APC 4

29 50 H02+.12 DSI 0.94 ODSCC TSP AXIAL In Service via APC 4

29 51 H01+.00 DSI 0.92 ODSCC TSP AXIAL In Service via APC 4

29 56 H02-.06 DSI 0.78 ODSCC TSP AXIAL In Service via APC 4

29 57 H01+.00 DSI 0.51 ODSCC TSP AXIAL In Service via APC 4

29 58 H01-.08 DSI 1.15 ODSCC TSP AXIAL In Service via APC 4

29 58 H01+.10 SAI 0.22 ODSCC TSP AXIAL In Service via APC 4

29 59 H06-.12 DSI 0.43 ODSCC TSP AXIAL In Service via APC 4

29 63 H01+.00 DSI 0.49 ODSCC TSP AXIAL In Service via APC 4

29 71 H05+.03 DSI 0.16 ODSCC TSP AXIAL In Service via APC 4

29 73 H03-.03 DSI 0.82 ODSCC TSP AXIAL In Service via APC 4

29 76 C05+.08 DSI 0.25 ODSCC TSP AXIAL In Service via APC 4

30 14 C01-.31 DSI 0.35 ODSCC TSP AXIAL In Service via APC 4

30 17 H03+.06 DSI 0.31 ODSCC TSP AXIAL In Service via APC 4

30 18 H02+.14 DSI 0.47 ODSCC TSP AXIAL In Service via APC 4

30 21 H02+.17 DSI 0.92 ODSCC TSP AXIAL In Service via APC 4

30 25 H02+.14 DSI 0.5 ODSCC TSP AXIAL In Service via APC 4

30 28 H04+.00 DSI 0.14 ODSCC TSP AXIAL In Service via APC 4

30 54 H01-.03 DSI 0.51 ODSCC TSP AXIAL In Service via APC 4

30 54 H02+.00 DSI 0.46 ODSCC TSP AXIAL In Service via APC 4

30 71 H01-.03 DSI 0.6 ODSCC TSP AXIAL In Service via APC 4

30 74 C04+.03 DSI 0.37 ODSCC TSP AXIAL In Service via APC 4

30 76 C05+.03 DSI 0.33 ODSCC TSP AXIAL In Service via APC 4

30 76 C06+.00 DSI 0.45 ODSCC TSP AXIAL In Service via APC 4

30 77 H01+.00 DSI 1.21 ODSCC TSP AXIAL In Service via APC 4

30 80 H06-.06 DSI 0.45 ODSCC TSP AXIAL In Service via APC 4

30 81 H02-.06 DSI 0.4 ODSCC TSP AXIAL In Service via APC 4

31 34 H02-.03 DSI 0.49 ODSCC TSP AXIAL In Service via APC 4

31 39 H01+.03 DSI 0.61 ODSCC TSP AXIAL In Service via APC 4

31 40 H02+.06 DSI 0.65 ODSCC TSP AXIAL In Service via APC 4

31 40 H04-.03 DSI 0.64 ODSCC TSP AXIAL In Service via APC 4

31 51 H06-.03 DSI 0.37 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 76 of 88 4

31 54 H01-.03 DSI 0.54 ODSCC TSP AXIAL In Service via APC 4

31 55 H02+.00 DSI 0.81 ODSCC TSP AXIAL In Service via APC 4

31 58 H02+.06 DSI 0.95 ODSCC TSP AXIAL In Service via APC 4

31 58 H03+.00 DSI 1.63 ODSCC TSP AXIAL In Service via APC 4

31 58 H03+.14 SAI 0.23 ODSCC TSP AXIAL In Service via APC 4

31 58 H03+.18 SAI 0.18 ODSCC TSP AXIAL In Service via APC 4

31 58 H03+.27 SAI 0.3 ODSCC TSP AXIAL In Service via APC 4

31 59 H02+.06 DSI 0.55 ODSCC TSP AXIAL In Service via APC 4

31 59 H07-.15 DSI 0.47 ODSCC TSP AXIAL In Service via APC 4

31 71 H01-.03 DSI 1.04 ODSCC TSP AXIAL In Service via APC 4

31 71 H01+.08 SAI 0.29 ODSCC TSP AXIAL In Service via APC 4

31 71 H01+.15 SAI 0.12 ODSCC TSP AXIAL In Service via APC 4

31 71 H01+.21 SAI 0.15 ODSCC TSP AXIAL In Service via APC 4

31 71 H02+.00 DSI 1.12 ODSCC TSP AXIAL In Service via APC 4

31 71 H02+.17 SAI 0.17 ODSCC TSP AXIAL In Service via APC 4

31 71 H02+.27 SAI 0.33 ODSCC TSP AXIAL In Service via APC 4

31 71 H03-.12 DSI 0.39 ODSCC TSP AXIAL In Service via APC 4

31 72 H01+.00 DSI 0.91 ODSCC TSP AXIAL In Service via APC 4

31 72 H02-.06 DSI 1.05 ODSCC TSP AXIAL In Service via APC 4

31 72 H02+.28 SAI 0.19 ODSCC TSP AXIAL In Service via APC 4

31 72 H02+.29 SAI 0.17 ODSCC TSP AXIAL In Service via APC 4

31 72 H03-.03 DSI 0.72 ODSCC TSP AXIAL In Service via APC 4

31 76 H03+.00 DSI 0.75 ODSCC TSP AXIAL In Service via APC 4

32 20 H02+.06 DSI 0.49 ODSCC TSP AXIAL In Service via APC 4

32 39 H01+.17 DSI 0.47 ODSCC TSP AXIAL In Service via APC 4

32 44 H04+.00 DSI 1.17 ODSCC TSP AXIAL In Service via APC 4

32 44 H04+.01 SAI 0.25 ODSCC TSP AXIAL In Service via APC 4

32 49 H01+.06 DSI 0.47 ODSCC TSP AXIAL In Service via APC 4

32 49 H02+.14 DSI 0.54 ODSCC TSP AXIAL In Service via APC 4

32 61 H02-.06 DSI 0.76 ODSCC TSP AXIAL In Service via APC 4

32 61 H02+.25 SAI 0.2 ODSCC TSP AXIAL In Service via APC 4

32 62 H01+.03 DSI 1.35 ODSCC TSP AXIAL In Service via APC 4

32 62 H01+.15 SAI 0.19 ODSCC TSP AXIAL In Service via APC 4

32 62 H01+.19 SAI 0.16 ODSCC TSP AXIAL In Service via APC 4

32 62 H01+.20 SAI 0.21 ODSCC TSP AXIAL In Service via APC 4

32 62 H02+.06 DSI 1.01 ODSCC TSP AXIAL In Service via APC 4

32 62 H02+.05 SAI 0.22 ODSCC TSP AXIAL In Service via APC 4

32 62 H02+.08 SAI 0.21 ODSCC TSP AXIAL In Service via APC 4

32 62 H02+.24 SAI 0.26 ODSCC TSP AXIAL In Service via APC 4

32 63 H02+.03 DSI 0.98 ODSCC TSP AXIAL In Service via APC 4

32 63 H04-.06 DSI 0.65 ODSCC TSP AXIAL In Service via APC 4

32 64 H01+.00 DSI 0.49 ODSCC TSP AXIAL In Service via APC 4

32 64 H02+.11 DSI 1.1 ODSCC TSP AXIAL In Service via APC 4

32 64 H02+.08 SAI 0.12 ODSCC TSP AXIAL In Service via APC 4

32 64 H02+.29 SAI 0.18 ODSCC TSP AXIAL In Service via APC 4

32 64 H02+.33 SAI 0.25 ODSCC TSP AXIAL In Service via APC 4

32 64 H02+.35 SAI 0.16 ODSCC TSP AXIAL In Service via APC 4

32 65 H01-.09 DSI 0.48 ODSCC TSP AXIAL In Service via APC 4

32 65 H02+.00 DSI 0.62 ODSCC TSP AXIAL In Service via APC 4

32 65 H03-.03 DSI 0.29 ODSCC TSP AXIAL In Service via APC 4

32 66 H01-.16 DSI 0.69 ODSCC TSP AXIAL In Service via APC 4

32 66 H03+.14 DSI 1.17 ODSCC TSP AXIAL In Service via APC 4

32 66 H03+.08 SAI 0.27 ODSCC TSP AXIAL In Service via APC 4

32 66 H03+.09 SAI 0.18 ODSCC TSP AXIAL In Service via APC 4

32 67 H02+.00 DSI 1.35 ODSCC TSP AXIAL In Service via APC 4

32 67 H02+.30 SAI 0.29 ODSCC TSP AXIAL In Service via APC 4

32 67 H03+.00 DSI 0.62 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 77 of 88 4

32 68 H02-.03 DSI 0.64 ODSCC TSP AXIAL In Service via APC 4

32 69 H01-.09 DSI 0.82 ODSCC TSP AXIAL In Service via APC 4

32 69 H02+.06 DSI 0.49 ODSCC TSP AXIAL In Service via APC 4

32 70 H01+.00 DSI 0.49 ODSCC TSP AXIAL In Service via APC 4

32 70 H02+.06 DSI 0.81 ODSCC TSP AXIAL In Service via APC 4

32 70 H03+.03 DSI 0.42 ODSCC TSP AXIAL In Service via APC 4

32 70 H04-.06 DSI 0.56 ODSCC TSP AXIAL In Service via APC 4

32 71 H01+.03 DSI 0.47 ODSCC TSP AXIAL In Service via APC 4

32 71 H03+.00 DSI 0.56 ODSCC TSP AXIAL In Service via APC 4

32 73 H01-.03 DSI 0.59 ODSCC TSP AXIAL In Service via APC 4

32 74 H01-.03 DSI 0.49 ODSCC TSP AXIAL In Service via APC 4

32 75 H02+.00 DSI 0.56 ODSCC TSP AXIAL In Service via APC 4

32 75 H04-.09 DSI 0.76 ODSCC TSP AXIAL In Service via APC 4

32 77 H03+.00 DSI 1.06 ODSCC TSP AXIAL In Service via APC 4

32 77 H04-.03 DSI 0.72 ODSCC TSP AXIAL In Service via APC 4

33 45 H01+.20 DSI 0.7 ODSCC TSP AXIAL In Service via APC 4

33 51 H02+.15 DSI 0.79 ODSCC TSP AXIAL In Service via APC 4

33 54 H01+.00 DSI 0.37 ODSCC TSP AXIAL In Service via APC 4

33 55 H01+.00 DSI 0.64 ODSCC TSP AXIAL In Service via APC 4

33 56 H01-.03 DSI 0.93 ODSCC TSP AXIAL In Service via APC 4

33 59 H02-.09 DSI 0.51 ODSCC TSP AXIAL In Service via APC 4

33 65 H02+.00 DSI 0.95 ODSCC TSP AXIAL In Service via APC 4

33 67 H02+.00 DSI 0.92 ODSCC TSP AXIAL In Service via APC 4

33 68 H01+.00 DSI 0.71 ODSCC TSP AXIAL In Service via APC 4

34 24 H04+.06 DSI 0.6 ODSCC TSP AXIAL In Service via APC 4

34 25 H02+.08 DSI 0.85 ODSCC TSP AXIAL In Service via APC 4

34 28 H01+.19 DSI 0.74 ODSCC TSP AXIAL In Service via APC 4

34 30 H02+.14 DSI 0.52 ODSCC TSP AXIAL In Service via APC 4

34 32 H02+.14 DSI 0.49 ODSCC TSP AXIAL In Service via APC 4

34 33 H02+.00 DSI 0.65 ODSCC TSP AXIAL In Service via APC 4

34 33 H03+.00 DSI 0.33 ODSCC TSP AXIAL In Service via APC 4

34 43 H01+.12 DSI 0.53 ODSCC TSP AXIAL In Service via APC 4

34 44 H02-.12 DSI 0.78 ODSCC TSP AXIAL In Service via APC 4

34 47 H01+.20 DSI 0.86 ODSCC TSP AXIAL In Service via APC 4

34 47 H03+.15 DSI 0.61 ODSCC TSP AXIAL In Service via APC 4

34 47 H04+.17 DSI 0.73 ODSCC TSP AXIAL In Service via APC 4

34 47 H04+.25 SAI 0.22 ODSCC TSP AXIAL In Service via APC 4

34 48 H01+.06 DSI 0.36 ODSCC TSP AXIAL In Service via APC 4

34 49 H02+.12 DSI 0.55 ODSCC TSP AXIAL In Service via APC 4

34 50 H03-.03 DSI 1.04 ODSCC TSP AXIAL In Service via APC 4

34 50 H03+.07 SAI 0.17 ODSCC TSP AXIAL In Service via APC 4

34 50 H03+.24 SAI 0.11 ODSCC TSP AXIAL In Service via APC 4

34 50 H03+.27 SAI 0.36 ODSCC TSP AXIAL In Service via APC 4

34 50 H04+.09 DSI 0.57 ODSCC TSP AXIAL In Service via APC 4

34 55 H03-.09 DSI 0.47 ODSCC TSP AXIAL In Service via APC 4

34 56 H01+.00 DSI 0.5 ODSCC TSP AXIAL In Service via APC 4

34 58 H02+.06 DSI 0.86 ODSCC TSP AXIAL In Service via APC 4

34 59 H02+.00 DSI 0.45 ODSCC TSP AXIAL In Service via APC 4

34 64 H02-.14 DSI 0.66 ODSCC TSP AXIAL In Service via APC 4

34 65 H01-.06 DSI 0.87 ODSCC TSP AXIAL In Service via APC 4

34 65 H02+.06 DSI 0.8 ODSCC TSP AXIAL In Service via APC 4

34 65 H03+.03 DSI 0.58 ODSCC TSP AXIAL In Service via APC 4

34 66 H01+.08 DSI 0.71 ODSCC TSP AXIAL In Service via APC 4

34 68 H02-.08 DSI 0.52 ODSCC TSP AXIAL In Service via APC 4

34 69 H02+.00 DSI 0.49 ODSCC TSP AXIAL In Service via APC 4

34 69 H03-.03 DSI 0.41 ODSCC TSP AXIAL In Service via APC 4

34 70 H03-.06 DSI 0.43 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 78 of 88 4

34 71 H02+.00 DSI 0.93 ODSCC TSP AXIAL In Service via APC 4

34 72 H01+.20 DSI 0.78 ODSCC TSP AXIAL In Service via APC 4

34 77 H03+.00 DSI 0.74 ODSCC TSP AXIAL In Service via APC 4

34 78 H03-.08 DSI 0.83 ODSCC TSP AXIAL In Service via APC 4

35 20 H03+.11 DSI 0.72 ODSCC TSP AXIAL In Service via APC 4

35 33 H03+.11 DSI 0.29 ODSCC TSP AXIAL In Service via APC 4

35 35 H02+.03 DSI 0.38 ODSCC TSP AXIAL In Service via APC 4

35 38 H03+.06 DSI 0.51 ODSCC TSP AXIAL In Service via APC 4

35 43 H04+.03 DSI 0.25 ODSCC TSP AXIAL In Service via APC 4

35 46 H06+.09 DSI 0.41 ODSCC TSP AXIAL In Service via APC 4

35 62 H02-.03 DSI 0.5 ODSCC TSP AXIAL In Service via APC 4

35 65 C03+.03 DSI 0.24 ODSCC TSP AXIAL In Service via APC 4

35 65 H03-.09 DSI 0.33 ODSCC TSP AXIAL In Service via APC 4

35 66 H02+.17 DSI 0.65 ODSCC TSP AXIAL In Service via APC 4

35 69 C06+.00 DSI 0.29 ODSCC TSP AXIAL In Service via APC 4

35 69 H01-.06 DSI 0.31 ODSCC TSP AXIAL In Service via APC 4

35 69 H02-.06 DSI 1.19 ODSCC TSP AXIAL In Service via APC 4

35 71 H01-.06 DSI 1.09 ODSCC TSP AXIAL In Service via APC 4

35 71 H01+.29 SAI 0.2 ODSCC TSP AXIAL In Service via APC 4

35 72 H02+.03 DSI 0.4 ODSCC TSP AXIAL In Service via APC 4

35 73 H01-.12 DSI 0.57 ODSCC TSP AXIAL In Service via APC 4

35 73 H02+.00 DSI 0.96 ODSCC TSP AXIAL In Service via APC 4

35 74 H04+.00 DSI 0.42 ODSCC TSP AXIAL In Service via APC 4

36 24 H04+.08 DSI 0.7 ODSCC TSP AXIAL In Service via APC 4

36 26 H04+.03 DSI 0.35 ODSCC TSP AXIAL In Service via APC 4

36 36 H04-.06 DSI 0.55 ODSCC TSP AXIAL In Service via APC 4

36 47 H01+.09 DSI 0.45 ODSCC TSP AXIAL In Service via APC 4

36 48 H02-.06 DSI 0.53 ODSCC TSP AXIAL In Service via APC 4

36 52 H01+.12 DSI 0.34 ODSCC TSP AXIAL In Service via APC 4

36 52 H02+.23 DSI 0.65 ODSCC TSP AXIAL In Service via APC 4

36 52 H03+.03 DSI 0.3 ODSCC TSP AXIAL In Service via APC 4

36 54 H04+.03 DSI 0.31 ODSCC TSP AXIAL In Service via APC 4

36 56 H02+.08 DSI 0.81 ODSCC TSP AXIAL In Service via APC 4

36 57 H02+.12 DSI 0.56 ODSCC TSP AXIAL In Service via APC 4

36 57 H03+.00 DSI 0.49 ODSCC TSP AXIAL In Service via APC 4

36 59 H01-.03 DSI 0.42 ODSCC TSP AXIAL In Service via APC 4

36 60 H02-.06 DSI 0.54 ODSCC TSP AXIAL In Service via APC 4

36 60 H03+.03 DSI 0.34 ODSCC TSP AXIAL In Service via APC 4

36 62 H02+.00 DSI 1.17 ODSCC TSP AXIAL In Service via APC 4

36 62 H02+.04 SAI 0.49 ODSCC TSP AXIAL In Service via APC 4

36 64 H02+.17 DSI 0.67 ODSCC TSP AXIAL In Service via APC 4

36 65 H01+.00 DSI 0.93 ODSCC TSP AXIAL In Service via APC 4

36 65 H02-.06 DSI 0.7 ODSCC TSP AXIAL In Service via APC 4

36 67 H06-.09 DSI 0.24 ODSCC TSP AXIAL In Service via APC 4

36 68 H02-.03 DSI 0.62 ODSCC TSP AXIAL In Service via APC 4

36 71 H01-.06 DSI 0.92 ODSCC TSP AXIAL In Service via APC 4

36 72 H01+.06 DSI 0.5 ODSCC TSP AXIAL In Service via APC 4

37 35 H02+.11 DSI 0.42 ODSCC TSP AXIAL In Service via APC 4

37 45 H02+.12 DSI 0.46 ODSCC TSP AXIAL In Service via APC 4

37 45 H03+.06 DSI 0.78 ODSCC TSP AXIAL In Service via APC 4

37 46 C06+.00 DSI 0.38 ODSCC TSP AXIAL In Service via APC 4

37 51 H02+.12 DSI 0.42 ODSCC TSP AXIAL In Service via APC 4

37 62 H04-.06 DSI 0.33 ODSCC TSP AXIAL In Service via APC 4

37 63 H01+.00 DSI 0.64 ODSCC TSP AXIAL In Service via APC 4

37 63 H03+.00 DSI 0.23 ODSCC TSP AXIAL In Service via APC 4

37 65 H02-.03 DSI 0.5 ODSCC TSP AXIAL In Service via APC 4

37 67 C05+.12 DSI 0.46 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 79 of 88 4

37 67 H01+.12 DSI 0.97 ODSCC TSP AXIAL In Service via APC 4

37 71 H01-.03 DSI 0.4 ODSCC TSP AXIAL In Service via APC 4

37 72 H01+.03 DSI 0.59 ODSCC TSP AXIAL In Service via APC 4

37 73 H02-.06 DSI 0.59 ODSCC TSP AXIAL In Service via APC 4

38 21 H01+.08 DSI 0.45 ODSCC TSP AXIAL In Service via APC 4

38 24 H03+.11 DSI 0.42 ODSCC TSP AXIAL In Service via APC 4

38 25 H02+.08 DSI 0.54 ODSCC TSP AXIAL In Service via APC 4

38 25 H05+.03 DSI 0.29 ODSCC TSP AXIAL In Service via APC 4

38 26 H02+.06 DSI 0.45 ODSCC TSP AXIAL In Service via APC 4

38 26 H04+.00 DSI 0.22 ODSCC TSP AXIAL In Service via APC 4

38 27 H01+.06 DSI 0.45 ODSCC TSP AXIAL In Service via APC 4

38 27 H01+.07 SAI 0.21 ODSCC TSP AXIAL In Service via APC 4

38 30 H02+.14 DSI 0.62 ODSCC TSP AXIAL In Service via APC 4

38 32 H02+.14 DSI 0.5 ODSCC TSP AXIAL In Service via APC 4

38 34 H02+.11 DSI 0.78 ODSCC TSP AXIAL In Service via APC 4

38 38 H04+.08 DSI 0.29 ODSCC TSP AXIAL In Service via APC 4

38 49 H02+.09 DSI 0.52 ODSCC TSP AXIAL In Service via APC 4

38 55 H02-.18 DSI 0.61 ODSCC TSP AXIAL In Service via APC 4

38 57 H02-.21 DSI 0.85 ODSCC TSP AXIAL In Service via APC 4

38 62 H04+.00 DSI 0.29 ODSCC TSP AXIAL In Service via APC 4

38 71 H03+.00 DSI 0.51 ODSCC TSP AXIAL In Service via APC 4

38 71 H03+.27 SAI 0.19 ODSCC TSP AXIAL In Service via APC 4

38 72 H02-.06 DSI 0.92 ODSCC TSP AXIAL In Service via APC 4

38 74 H03-.03 DSI 0.6 ODSCC TSP AXIAL In Service via APC 4

38 74 H04-.06 DSI 0.31 ODSCC TSP AXIAL In Service via APC 4

39 22 H01-.12 DSI 0.39 ODSCC TSP AXIAL In Service via APC 4

39 27 H03+.08 DSI 0.48 ODSCC TSP AXIAL In Service via APC 4

39 37 H03+.08 DSI 0.49 ODSCC TSP AXIAL In Service via APC 4

39 38 C05+.09 DSI 0.48 ODSCC TSP AXIAL In Service via APC 4

39 41 H03+.14 DSI 0.47 ODSCC TSP AXIAL In Service via APC 4

39 41 H04+.03 DSI 0.28 ODSCC TSP AXIAL In Service via APC 4

39 42 H03-.03 DSI 0.51 ODSCC TSP AXIAL In Service via APC 4

39 42 H04+.00 DSI 0.29 ODSCC TSP AXIAL In Service via APC 4

39 45 H02+.23 DSI 0.51 ODSCC TSP AXIAL In Service via APC 4

39 45 H03+.12 DSI 0.43 ODSCC TSP AXIAL In Service via APC 4

39 47 H02+.14 DSI 0.3 ODSCC TSP AXIAL In Service via APC 4

39 47 H03+.09 DSI 0.64 ODSCC TSP AXIAL In Service via APC 4

39 49 H02+.17 DSI 0.8 ODSCC TSP AXIAL In Service via APC 4

39 50 H02+.12 DSI 0.44 ODSCC TSP AXIAL In Service via APC 4

39 64 H02+.00 DSI 0.66 ODSCC TSP AXIAL In Service via APC 4

39 66 H01+.00 DSI 0.27 ODSCC TSP AXIAL In Service via APC 4

39 67 H02-.09 DSI 0.3 ODSCC TSP AXIAL In Service via APC 4

39 68 H03+.11 DSI 0.61 ODSCC TSP AXIAL In Service via APC 4

39 70 H03-.17 DSI 0.65 ODSCC TSP AXIAL In Service via APC 4

40 29 H03+.06 DSI 0.31 ODSCC TSP AXIAL In Service via APC 4

40 33 H02+.17 DSI 0.46 ODSCC TSP AXIAL In Service via APC 4

40 57 H01+.03 DSI 0.81 ODSCC TSP AXIAL In Service via APC 4

40 59 C03+.06 DSI 0.34 ODSCC TSP AXIAL In Service via APC 4

40 67 H01-.06 DSI 0.65 ODSCC TSP AXIAL In Service via APC 4

40 69 H02-.03 DSI 0.41 ODSCC TSP AXIAL In Service via APC 4

40 71 H03-.03 DSI 0.54 ODSCC TSP AXIAL In Service via APC 4

41 37 H03+.11 DSI 0.47 ODSCC TSP AXIAL In Service via APC 4

41 52 H01+.09 DSI 0.52 ODSCC TSP AXIAL In Service via APC 4

41 52 H02+.12 DSI 0.73 ODSCC TSP AXIAL In Service via APC 4

41 57 H01+.06 DSI 0.66 ODSCC TSP AXIAL In Service via APC 4

41 58 H01+.00 DSI 0.39 ODSCC TSP AXIAL In Service via APC 4

41 58 H02+.00 DSI 0.65 ODSCC TSP AXIAL In Service via APC

Table 7 ODSCC Tube Support Plate Axial 80 of 88 4

41 65 C02-.14 DSI 0.28 ODSCC TSP AXIAL In Service via APC 4

42 38 H02+.08 DSI 0.5 ODSCC TSP AXIAL In Service via APC 4

43 44 C05+.06 DSI 0.32 ODSCC TSP AXIAL In Service via APC 4

43 53 C02-.20 DSI 0.35 ODSCC TSP AXIAL In Service via APC 4

43 65 H01-.03 DSI 0.31 ODSCC TSP AXIAL In Service via APC 4

45 48 C01-.37 DSI 0.24 ODSCC TSP AXIAL In Service via APC 4

45 49 C01-.37 DSI 0.22 ODSCC TSP AXIAL In Service via APC 4

45 51 H04-.09 DSI 0.49 ODSCC TSP AXIAL In Service via APC 4

45 52 H04+.15 DSI 0.46 ODSCC TSP AXIAL In Service via APC

Table 8 ODSCC Tube Support Plate Circumferential 81 of 88 The following indication is circumferential outside diameter stress corrosion cracking (ODSCC) at the tube support plates (TSP). This tube support plate intersection had two large dents. The stresses associated with the dents created circumferential cracking.

These indications are detected by the plus point examination and are plugged on detection.

SG ROW COL LOCATION INDIC VOLTAGE CHARACTERIZATION RESOLUTION 1

45 39 H07-.25 SCI 0.5 ODSCC TSP CIRC PLUG/STAB

Table 9 OD Volumetric 82 of 88 The following indication was an OD Volumetric above the hot leg top-or-tubesheet. This indication was 0.37 volts and therefore in accordance with the EPRI In-Situ Pressure Test Guidelines did not require In-Situ Pressure testing because a 0.37 volt indication has at less a 95-percent probability of maintaining a safety factor greater than 3 against burst at normal operating pressure differential. It is also well below the In-Situ pressure test voltage threshold and therefore maintains a greater than 95-percent probability of not leaking at Main Steam Line Break pressure differential.

SG ROW COL LOCATION INDIC VOLTAGE CHARACTERIZATION RESOLUTION 2

12 65 HTS+7.66 SVI 0.37 Volumetric PLUGGED

Table 10 PWSCC Top of Tubesheet Axial 83 of 88 The indications below are axial (SAI) primary water stress corrosion cracking (PWSCC) below the top of the tubesheet. These indications were discussed in the 90 day Report.

These indications are detected by the plus point examination and are plugged on detection.

SG ROW COL LOCATION INDIC VOLTS CHARACTERIZATION RESOLUTION 4

4 25 HTS-10.64 SAI 3.04 PWSCC HTS AXIAL PLUGGED 4

4 25 HTS-8.13 SAI 0.95 PWSCC HTS AXIAL PLUGGED

Table 11 PWSCC Top of Tubesheet Circumferential 84 of 88 The indications below are circumferential (SCI) primary water stress corrosion cracking (PWSCC) at the top of the tubesheet. These indications are detected by the plus point examination and are plugged on detection.

SG ROW COL LOCATION INDIC VOLTS CHARACTERIZATION RESOLUTION 2

20 70 HTS-.11 SCI 0.41 PWSCC HTS CIRC PLUGGED

Table 12 PWSCC Tube Support Plate Axial 85 of 88 The indications below are axial (SAI) primary water stress corrosion cracking (PWSCC) at tube support plate intersections. These indications are detected by the plus point examination and are plugged on detection. The below locations were dented.

SG3R12C4 indications length was less than the LSTR and therefore an In-Situ proof test was not required in accordance with the EPRI In-Situ Pressure Test Guidelines. The other indications are below the 0.5 volt in-situ pressure screening voltage and therefore, maintain a greater than 95-percent probability of maintaining a safety factor of three against burst during normal operation.

SG ROW COL LOCATION INDIC VOLTS CHARACTERIZATION RESOLUTION 1

29 78 H05+.19 SAI 0.41 PWSCC TSP AXIAL PLUGGED 3

12 4

H01-.25 SAI 0.53 PWSCC TSP AXIAL PLUGGED 3

24 86 H07-.02 SAI 0.37 PWSCC TSP AXIAL PLUGGED

Table 13 PWSCC Tube Support Plate Circumferential 86 of 88 The indications below are circumferential (SCI) primary water stress corrosion cracking (PWSCC) tube support plate intersections. These indications are detected by the plus point examination and are plugged on detection. The below location was dented. The below indications CA was below the CATWSL and therefore a proof test was not required in accordance with the EPRI In-Situ Pressure Test Guidelines.

SG ROW COL LOCATION INDIC VOLTS CHARACTERIZATION RESOLUTION 3

12 56 H07+.03 SCI 1.49 PWSCC TSP CIRC PLUGGED 3

12 56 H07+.03 SCI 0.85 PWSCC TSP CIRC PLUGGED

Table 14 PWSCC U-bend Axial 87 of 88 The indications below are axial (SAI) primary water stress corrosion cracking (PWSCC) in the U-bend region. These indications are detected by the plus point examination and are plugged on detection. This indications length was less than the LSTR and therefore an In-Situ proof test was not required in accordance with the EPRI In-Situ Pressure Test Guidelines.

SG ROW COL LOCATION INDIC VOLTS CHARACTERIZATION RESOLUTION 1

1 52 H07+3.94 SAI 1.86 PWSCC UBEND AXIAL PLUGGED

Table 15 PWSCC U-Bend Circumferential 88 of 88 The indications below are circumferential (SCI) primary water stress corrosion cracking (PWSCC) in the U-bend region. These indications are detected by the plus point examination and are plugged on detection. The below indications CA was below the CATWSL and therefore a proof test was not required in accordance with the EPRI In-Situ Pressure Test Guidelines.

SG ROW COL LOCATION INDIC VOLTS CHARACTERIZATION RESOLUTION 2

3 94 H07+18.72 SCI 0.77 PWSCC UBEND CIRC PLUGGED 2

3 94 H07+16.23 SCI 0.54 PWSCC UBEND CIRC PLUGGED 2

4 53 H07+22.26 SCI 0.61 PWSCC UBEND CIRC PLUGGED