ML071940314
| ML071940314 | |
| Person / Time | |
|---|---|
| Site: | San Onofre |
| Issue date: | 06/28/2007 |
| From: | Southern California Edison Co |
| To: | Office of Nuclear Reactor Regulation |
| References | |
| AMD 212/204 B06-006 | |
| Download: ML071940314 (48) | |
Text
SONGS UNIT 2 SINGLE-SIDED Operating License & Technical Specification/Licensee Controlled Specification AMD 212/204 B06-006 Revise Unit 2 Operating License by removing pages and inserting the enclosed pages.
The revised pages are identified by the captioned amendment number and/or dates and contain marginal/lines indicating the areas of change. Please direct any questions regarding filing of information to: (949) 368-6972 or email CDM Controlled Manuals Desk.
REMOVE:
INSERT:
VOLUME 1 VOLUME 1 BEHIND: List of Effective Pages - "Blue Tab" BEHIND: List of Effective Pages - "Blue Tab" List of Effective Pages - Pages 1-12 4/8/07 List of Effective Pages - Pages 1-12 6/21/07 BEHIND: Facility Operating License "Blue Tab" BEHIND: Facility Operating License "Blue Tab" Facility Operating License Page 2 AMD 211 Facility Operating License Page 2 AMD 212 Page 3 AMD 211 Page 3 AMD 212 BEHIND: 3.7 Plant Systems "Blue Tab" BEHIND: 3.7 Plant Systems "Blue Tab" Page 3.7-1 AMD 127 Page 3.7-1 AMD 212 Page 3.7-3 AMD 127 Page 3.7-3 AMD 212 Page 3.7-4 AMD 163 Page 3.7-4 AMD 212 VOLUME 3 VOLUME 3 BEHIND: B 3.7 "Blue Tab" BEHIND: B 3.7 "Blue Tab" Page B 3.7-1 Page B 3.7-3 AMD 127 8/13/01 Paqe B 3.7-1 AMD 212 6/21/07 AMD 127 8/18/98 Page B 3.7-3 AMD 212 6/21/07 Page B 3.7-4 AMD 127 No Date Page B 3.7-4 AMD 212 6/21/07 Page B 3.7-5 AMD 127 No Date Page B 3.7-5 AMD 212 6/21/07 Page B 3.7-6 AMD 127 No Date Page B 3.7-6 AMD 212 6/21/07 Filing Instructions Reviewed & Approved:
~A 0~7 Signature/NRA Date Signature/C"bM Processor
[late" Page 1 of 1 kjiLý,
APPENDIX A TO LICENSE NO.
NPF-1O SAN ONOFRE UNIT 2 TECHNICAL SPECIFICATIONS (NUREG-0741)
LIST OF EFFECTIVE PAGES Page No.
Volume Amendment/Date Page No.
Volume Amendment/Date LOEP-1 LOEP-2 LOEP-3 LOEP-4 LOEP-4a LOEP-5 LOEP-6 LOEP-7 LOEP-8 LOEP-9 LOEP-1O LOEP-11 LOEP-12 iiiii iv v
vi vii viii 1.1-2 1.1-2 1.1-3 1.1-4 1,1-5 1.1-6 1.1-7 1.2-1 1.2-2 1.2-3 1.3-1 1.3-2 1.3-3 1.3-4 1.3-5 1.3-6 1.3-7 1.3-8 1.3-9 1.3-10 1.3-11 1.3-12 1.3-13 1.4-i 1.4-2.
1.4-3 1.4-4 212 208 212 211 168 207 200 197 208 204 212 211 193 127 208 208 197 127 208 208 127 127 188 204 203 200 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 06/21/07 01/25/07 06/21/07 04/04/07 12/21/06 11/18/05 07/19/05 12/05/06 09/19/06 06/21/07 041/05/07 03/07/07 2.0-1 2.0-2 3.0-1 3.0-2 3.0-3 3.0-4 3.0-5 3.1-1 3.1-2 3.1-3 3.1-4
.3.1-5 3.1-6 3.1-7 3.1-8 3.1-9 3.1-10 3.1-11 3.1-12 3.1-13 3.1-14 3.1-15 3.1-16 3.1-17 3.1-18 3.1-19 3.1-20 3.1-21 3.1-22 3.1-23 3.1-24 3.1-25 3.1-26 3.1-27 3.1-28 3.1-29 3.2-1 3.2-2 3.2-3 3.2-4 3.2-5 3.2-6 3.2-7 3.2-8 3.2-9 3.2-10 3.2-11 3.2-12 11
.1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 207 207 127 127 127 186 127 200 200 200 127 127 127 200 200 127 127 127 200 127 200 200 200 127 127 127 127 163 175 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 200 127 127 127 Page I of 12 Amendment 212 06/21/07
APPENDIX A TO LICENSE NO.
NPF-1O SAN ONOFRE UNIT 2 TECHNICAL SPECIFICATIONS (NUREG-0741)
LIST OF EFFECTIVE PAGES Page No.
Volume Amendment/Date Page No.
Volume Amendment/Date 3.3-1 3.3-2 3.3-3 3.3-4 3.3-5 3.3-6 3.3-7 3.3-8 3.3-9 3.3-10 3.3-11 3.3-12 3.3-13 3.3-14 3.3-15 3.3-16 3.3-17 3.3-18 3.3-19 3.3-20 3.3-21 3.3-22 3.3-23 3.3-24 3.3-25 3.3-26 3.3-27 3.3-28 3.3-29 3.3-30 3.3-31 3.3-32 3.3-33 3.3-34 3.3-35 3.3-36 3.3-37 3.3-38 3.3-39 3.3-40 3.3-41 3.3-42 3.3-43 3.3-44 3.3-45 3.3-46 3.3-47 3.3-48 3.3-49 127 127 127 127 127 147
.133 150 150 127 127 133 147 127 127 133 127 127 127 133 127 157 157 157 157 127 127 127 133 127 127 127 127 196 132 132 132 132 132 175 160 208 208 127 194 194 194 127 127 3.3-50 3.3-51 3.3-52 3.4-1 3.4-2 3.4-3 3.4-4 3.4-5 3.4-6 3.4-7 3.4-8 3.4-9 3.4-10 3.4-11 3.4-12 3.4-13 3.4-14 3.4-15 3.4-16 3.4-17 3.4-18 3.4-19 3.4-20 3.4-21 3.4-22 3.4-23 3.4-24 3.4-25 3.4-26 3.4-27 3.4-28 3.4-29 3.4-30 3.4-31 3.4-32 3.4-33 3.4-34 3.4-35 3.4-36 3.4-37 3.4-38 3.4-39 3.4-40 3.4-41 3.4-42 3.4-43 3.4-44 3.4-45 127 175 127 149 149 149 127 203 203 203 203 203 203 203 203 127 197 127 175 175 203 175 127 17.5 203 175 175 175 161 155 156 156 203 203 127 203 143 203 127 204 204 127 127 127 127 127 127 127 01/25/07 01/25/07 Page 2 of 12 Amendment 208 01/25/07
APPENDIX A TO LICENSE NO.
NPF-1O SAN ONOFRE UNIT 2 TECHNICAL SPECIFICATIONS (NUREG-0741)
LIST OF EFFECTIVE PAGES Page No.
Volume Amendment/Date Page No.
Volume Amendment/Date 3.4-46 3.4-47 3.4-48 3.4-49 3.4-50 3.4-51 3.4-52 3.5-1 3.5-2 3.5-3 3.5-4 3.5-5 3.5-6 3.5-7 3.5 -8 3.5-9 3.5-10 3.5-11 3.6-1 3.6-2 3.6-3 3.6-4.
3.6-5 3.6-6 3.6-7 3.6-8 3.6-9:
3.6-10 3.6-11 3.6-12 3.6-13 3.6-14 3.6-15 3.6-16 3.6-17 3.6-18 3.6-19 3.6-20 3.6-21 3.6-22 3.6-23 3.6-24 3.6-25 3.6-26 3.7-1 3.7-2 3.7-3 3.7-4 3.7-5 127 127 127 127 127 204 204 139 135 127 139 127 190 127 127 127 127 127 127 144 127 127 127 144 127 127 127 127 127 165 201 201 127 127 127 171 127 127 127 127 159 159 127 127 212 127 212 212 127 3.7-6 3.7-7 3.7-8 3.7-9 3.7-10 3.7-11 3.7-12 3.7-13 3.7-14 3.7-15 3.7-16 3.7-17 3.7-18 3.7-19 3.7-19a 3.7-19b 3.7-19c 3.7-20 3.7-21 3.7-22 3.7-23 3.7-24 3.7-25 3.7-26 3.7-27 3.7-28 3.7-29 3.7-30 3.7-31 3.7-32 3.7-33 3.7-34 3.7-35 3.8-1 3.8-2 3.8-3 3.8-4 3.8-5 3.8-6 3.8-7 3.8-8 3.8-9 3.8-10 3.8-11
'3.8-12 3.8-13 3.8-14 3.8-15 3.8-16 127 127 127 127 127 164 127 127 191 147 162 127 127 127 129 129 129 127 127 181 127 181 177 177 208 208 127 127 127 131 131 131 127 141 141 127 127 179 211 158 179 158 158 158 158 169 179 158 127
.01/25/07 01/25/07.
Page 3 of 12 Amendment 212 06/21/07
APPENDIX A TO LICENSE NO.
NPF-1O SAN ONOFRE UNIT 2-TECHNICAL SPECIFICATIONS (NUREG-0741)
LIST OF EFFECTIVE PAGES Page No.
Volume Amendment/Date Page No.
Volume Amendment/Date 3.8-17 3.8-18 3.8-19 3.8-20 3.8-21 3.8-22 3.8-23 3.8-24 3.8-25 3.8-26 3.8-27 3.8-28 3.8-29 3.8-30 3.8-31 3.8-32 3.8-33 3.8-34 3.8-35 3.8-36 3.8-37 3.8-38 3.8-39 3.8-40 3.8-41 3.9-1 3.9-2.
3.9-3 3*9-4 3.9-5 3.9-6 3.9-6a 3.9-7 3.9-8 3.9-9
- 3.
9-9a 3.9-10 4.0-1 4.0-2 4.0-3 4.0-4 4.0-5 5.0-1 5.0-2 5.0-3 5.0-4 5.0-5 5.0-6 5.0-7 127 175 127 211 211 127 127 127 1227 127 175 127 127 127 127 127 127 127 127 175 127 127 127 175 127 127 175 127 193 127 175 175 153 153 175 153 134 199 127 127 131 131 207 207 207 207 207 184 127 5.0-8 5.0-9 5.0-20 5.0-11 5.0-12 5.0-13 5.0-14 5.0-15 5.0-15a 5.0-16 5.0-17 5.0-18 5.0-19 5.0-20 5.0-20a 5.0-20b 5.0-21 5.0-22 5.0-23 5.0-24 5.0-25 5.0-26 5.0-27 5.0-27a 5.0-28 5.0-29 5.0-30 5.0-31 207 178 127 170 178 204 204 206 206 204 208 204 204 204 198 144 127 127 195 127 127 200 203 203 204 204 197 207 Page 4 of 12 Amendment 211 04/04/07
APPENDIX A TO LICENSE NO.
NPF-1O SAN ONOFRE UNIT 2 TECHNICAL SPECIFICATIONS (NUREG-0741)
LIST OF EFFECTIVE PAGES Page No.
Bibliographic Data Sheet Appendix B Unit 2 Environmental Protection Plan 1-1 2-1 2-2 3-1 3-2 4-I 4-2 Appendix C Anti Trust Conditions Appendix C 2
3 Vol ume 1
1 1
1 1
1 1
1 1
" 1 1
1 1
1*
Amendment/Date dated February 17, 1982 dated February 17, 1982 dated February 17, 1982 dated February 17, 1982 dated February 17, 1982 dated February 17, 1982ý dated February 17, 1982 168 168 dated February 17, 1982 dated dated dated February February February 17.,
17, 17, 1982 1982 1982 Page 4a of 12 Amendment 168
APPENDIX A TO LICENSE NO. NPF-10 SAN ONOFRE UNIT 2 TECHNICAL SPECIFICATIONS (NUREG-0741)
LIST OF EFFECTIVE PAGES Page No.
Volume Amendment/Date Page No.
Volume Amendment/Date 2.0-1 2.0-2 2.0-3 2.0-3a 2.0-4 2.0-5 2.0-6 2.0-7 2.0-8 2.0-9 3.0-1 3.0-2 3.0-3 3.0-4 3.0-5 3.0-6 3.0-7 3.0-8 3.0-9 3.0-10 3.0-11 3.0-12 3.0-13 3.0-14 3.0-15 3.1-1 3.1-2 3.1-3 3.1-4 3.1-5 3.1-6 3.1-7 3.1-8 3.1-9 3.1-10 3.1-11 3.1-12 3.1-13 3.1-14 3.1-15 3.1-16 3.1-17 3.1-18 3.1-19 3.1-20 3.1-21 3.1-22 3.1-23 3.1-24 3.1-25 3.1-26 192 127 207 192 207 207 127 127 207 207 127 127 127 207 127 127 127 127 127 127 127 127 186 186 186 200 200 200 200 07/19/04 12/21/06 07/19/04 12/21/06 12/21/06 12/2 12/2 1/06 1/06 12/21/06 12 /01/98 10/25/02 05/08/02 05/08/02 11./18/05.
11/18/05 1 /18/05 11/18/05 3.1-27 3.1-28 3.1-29 3.1-30 3.1-31 3.1-32 3.1-33 3.1-34 3.1-35 3.1-36 3.1-37 3.1-38 3.1-39 3.1-40 3.1-41 3.1-42 3.1-43 3.1-43a 3.1-44 3.1-45 3 1-46 3.1-47 3.1-48 3.1-49 3.1-50 3.1-51 3.1-52 3.1-53 3.1-54 3.1-55 3.1-56 3.1-57 3.1-58 3.1-58a 3.1-58b 3.1-59 3.1-60 3.1-61 3.1-62 3.1-63 3.1-63a 3.1-64 3.1-65
- 3. 1-66 3.1-67 3.1-68 3.1-69 3.1-70 3.1-71 3.1-72 127 200 200 200 127 127 127 127 127 127 200 200 127 127 127 127 200 200 200 127 200 127 127 127 127 127 127 127 127 127 127 127 127 127 127 200 127 127 175 175 175 127 127 127 127 127 127 127 127 127 11/18/05 11/18/05 11/18/05 05/02/97 05/02/97 11/18/05 11/18/05 11/18/05 11/18/05 11/18/05 11/0183/0 08/03/0 1 08/03 /0 1
08/03/0 1 08/03/01 08/03/01 08/03/01 08/03/0 1 11/18/05 11/05/96 05/03/00 12/20/00 05/21/02 12/20/00 Deleted Deleted 200 11/18/05 200 11/18/05 200 11/18/05 200 11/18/05 Del eted Deleted 127 127 200 11/18/05 127 200 11/18/05 127 127 01/03/02 127 127 01/03/02 127 05/30/97 127 127 127 05/02/97 127 07/29/99 Page 5 of 12 Amendment 207 12/21/06
APPENDIX A TO LICENSE NO.
NPF-10 SAN ONOFRE UNIT 2 TECHNICAL SPECIFICATIONS (NUREG-0741)
LIST OF EFFECTIVE PAGES PaQe No.
Volume Amendment/Date Page No.
Volume Amendment/Date 3.1-73 3.1-74 3.1-75 3.1-76 3.1-77 3.1-78 3.1-79 3.1-80 3.2-1 3.2-2 3.2-3 3.2-4 3.2-5 3.2-6 3.2-7 3.2-8 3.2-9 3.2-10 3.2-11 3.2-12 3.2-13 3.2-14 3.2-15 3.2-16 3.2-17 3.2-18 3.2-19 3.2-20 3.2-21 3.2-22 3.2-23 3.2-24 3.2-25 3.2-26 3.2-27 3.2-28 3.2-29 3.2-30 3.2-31 3.2-32 3.2-33 3.2-34 3.2-35 3.2-36 3.2-37 3.2-38 3.2-39 3.2-40 3.2-41 3.3-1 127 127 127 127 127 127 127 127 127 127 127 192 127 127 127 127 127 127 127 192 127 127 127 127 127 127 192 127 127 127 127 127 127 127 127 127 192 200 127 127 127 127 127 127 127 192 127 127 127 127 05/29/97 05/29/97 07/19/04 07/19/04 3.3-2 3.3-3 3.3-4 3.3-5 3.3-6 3.3-7 3.3-8 3.3-9 3.3-10 3.3-11 3.3-12 3.3-13 3.3-14 3.3-15 3.3-16 3.3-17 3.3-18 3.3-19 3.3-20
- 3.3-21 3.3-22 3.3-23 3.3-24 3.3-25 3.3-26 3.3-26a 3.3-27 3.3-28 3.3-29 3.3-30 3.3-31 3.3-32 3.3-33 3.3-34 3.3-35 3.3-36 3.3-37 3.3-37a 3.3-38 3.3-39 3.3-40 3.3-41 3.3-42 3.3-43 3.3-44 3.3-45 3.3-46 3.3-47 3.3-48 3.3-49 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127
- 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 188 188 127 127 127 127 127 127 127 127 127 127 127 127 07/17/97 03/12/99 07/17/97 09/16/03 03/12/99 03/12/99 03/12/99 03/12/99 12/30/96 12/30/96.
12/30/96 05/29/97 05/02/97 03/12/99 03/12/99 03/12/99 03/12/99 03/12/99 09/16/03 07/17/97 09/25/98 09/25/98 12/30/96 12/30/96 12/30/96 12/30/96 09/18/98 09/18/98 07/19/04 07/19/04 11/18/05 07/19/04 Page 6 of 12 Amendment 200 11/18/05
APPENDIX A TO LICENSE NO.
NPF-1O SAN ONOFRE UNIT 2 TECHNICAL SPECIFICATIONS (NUREG-0741)
LIST OF EFFECTIVE PAGES Page No.
Vol ume Amendment/Date Page No.
Volume Amendment/Date 3.3-50 3.3-51 3.3-52 3.3-53 3.3-54 3.3-55 3.3-56 3.3-57 3.3-58 3.3-59 3.3-60 3.3-61 3.3-62 3.3-63 3.3-64 3.3-65 3.3-66 3.3-67 3.3-68 3.3-69 3.3-70 3.3-71 3.3-72 3.3-73 3.3-74 3.3-75 3.3-76 3.3-77 3.3-78 3.3-79 3.3-80 3.3-81 3.3-82 3.3-83 3.3-84 3.3-85 3.3-86 3.3-87 3.3-88 3.3-89 3.3-90 3.3-91 3.3-92 3.3-93 3.3-94 3.3-95 3.3-96 3.3-97 3.3-98 3.3-99 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 09/18/98 02/11/02 07/17/97 09/18/98 09/18/98 09/18/98 07/.17/97 12/30/96 12/30/96 12/30/96 05./28/97 12/30/96 07/17/97 3.3-100 3.3-101 3.3-102 3.3-103 3.3-103a 3.3-103b 3.3-103c 3.3-104 3.3-105 3.3-106 3.3-107 3.3-108 3.3-109
- 3.
3-110
- 3.
3-111
- 3.
3-112
- 3.
3-113 3.3-114
- 3.
3-115
- 3.
3-116
- 3.
3-117
- 3.
3-118 3.3-119 3.3-120 3.3-121 3.3-122 3.3-123 3.3-124 3.3-125 3.3-126 3.3-127 3.3-128 3.3-129 3.3-130
- 3.
3-131 3.3-132 3.3-133 3.3-134 3.3-135 3.3-136 3.3-137 3.3-138 3.3-139 3.3-140 3.3-141 3.3-142 3.3-143 3.3-144 3.3-145
- 3.
3-146 197 127 127 127 188 157 188 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 174 127 127 127 127 127 127 127 127 127 127 127 127 07/19/05 10/06/99 10/06/99 10/06/99 09/16/03 12/30/96 12/30/96 12/30/96 12/30/96 05/28/97 05/28/97 05/28/97 09/06/00 09/06/00 05/29/97 07/13/99 12/14/00 05/28/997 06/09/00 05/28/97 05/28/97 05/28/997 05/28/97 05/28/97 05/28/97 05/28/97 05/28/97 06/27/97 03/19/98 02/24/99 07/17/97 10/06/99 10/06/99 10/06/99 07/18/01 10/06/99 Page 7 of 12 Amendment 197 07/19/05
APPENDIX A TO LICENSE NO.
NPF-1O SAN ONOFRE UNIT 2 TECHNICAL SPECIFICATIONS (NUREG-0741)
LIST'OF EFFECTIVE PAGES Page No.
Vol ume Amendment/Date Page No.
Volume Amendment/Date 3.3-147 3.3-148 3.3-149 3.3-150 3.3-151 3.3-152 3.3-153 3.3-154 3.3-155 3.3-156 3.3-157 3.3-158 3.3-159 3.3-160 3.3-161 3.3-162 3.3-163 3.3-164 3.3-165 3.3-166 3.3.167 3.3-168 3.3-169 3.3-170 3.3-171 3.3-172 3.3-173 3.3-174 3.3-175 3.3-176 3.3-177 3.3-178 3.3-179 3.3-180 3.3-181 3.3-182 3.3-183 3.3-184 3.3-185 3.4-1 3.4-2 3.4-3 3.4-4 3.4-5 3.4-6 3.4-7 3.4-8 3.4-9 3.4-10 3.4-11 127 175 175 127 127 208 208 208 208 208 208 127 127 127 127 127 130 127 127 194 127 127 127 127 194 194 127 127 127 127 127 127 127 127 127 175 175 175 175 127 127 127 127 127 127 127 127 203 127 127 06/27/97 12/20/00 12/20/00 08/20/01 06/27/97 12/05/06 12/05/06 12/05/06 12/05/06 12/05/06 12/05/06 12/17/98 06/08/00 06/23/99 05/30/97 05/30/97 05/30/97 05/30/97 05/30/97 04/25/05 05/30/97 12/02/99 05/30/97 04/25/05 04/25/05 05/30/97.
05/30/97 03/06/06 10/30/98 10/30/98 04/24/01 04/24/01 07/29/96 12/20/00 12/20/00 12/20/00 12/20/00 02/24/99 02/24/99 02/24/99 3.4-12 3.4-13 3.4-14 3.4-15 3.4-16 3.4-17 3.4-18 3.4-19 3.4-20 3.4-21 3.4-22 3.4-23 3.4-24 3.4-25 3.4-26 3.4-27 3.4-28 3.4-29 3.4-30 3.4-31 3.4-32 3.4-33 3.4-34 3.4-35 3.4-36 3.4-37 3.4-38 3.4-38a 3.4-39 3.4-40 3.4-41 3.4-42 3.4-43 3.4-44 3.4-45 3.4-46 3.4-47 3.4-48 3.4-49 3.4-50 3.4-51 3.4-52 3.4-53 3.4-54 3.4-55 3.4-56 3.4-57 3.4-58 3.4-59 3.4-60 127 127 127 203 203 197 197 127 197 197 127 127 204 127 127 127 204-175 175 127 204 127 175 175 127 175 175 175 204 175 127 127 175 175 175 127 155 161 127 127 156 156 156 156 203 203 203 203 203 203 07/19/05 07/19/05 07/19/05 07/19/05 12/20/00 12/20/00 12/20/00 12/20/00 1,2/20/00 0,7/15/05 04/03/06 12/20/00 12/20/00 04/03/06 12/20/00 05/30/00 05/30/00 05/15/02 05/30/00 05/30/00 03/22/01 03/22/01 03/22/01 04/27/05 Page 8 of 12 Amendment 208 12/05/06
APPENDIX A TO LICENSE NO.
NPF-1O SAN ONOFRE UNIT 2 TECHNICAL SPECIFICATIONS (NUREG-0741)
LIST OF EFFECTIVE PAGES Page No.
Volume Amendment/Date Page No.
Volume Amendment/Date 3.4-61 3.4-62 3.4-63 3.4-64 3.4-65 3.4-66 3.4-67 3.4-68 3.4-69 3.4-70 3.4-71 3.4-72 3.4-73 3.4-74 3.4-75 3.4-76 3.4-77 3.4-78 3.4-79 3.4-80 3.4-81 3.4-82 3.4-83 3.4-84 3.4-85 3.4-86 3.4-87 3.4-88 3.4-89 3.4-90 3.4-91 3.4-92 3.4-93 3.4-94 3.4-95 3.4-96 3.4-97 3.4-98 3.4-99 3.4-100 3.5-1 3.5-2 3.5-3 3.5-4 3.5-5 3.5-6 3.5-7 3.5-8 3.5-9 3.5-10 3.5-10a 203 203 203 203 203 203 203 203 203 127 204 204 204 204 204 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 204 204 204 204 204 204 204 204 127 127 127 127 127 127 127 197 127 127 197 09/06/00 09/06/00 3.5-11 3.5-12 3.5-13 3.5-14 3.5-15 3.5-16 3.5-17 3.5-18 3.5-19 3.5-20 3.5-20a 3.5-21 3.5-22 3.5-23 3.5-24 3.5-25 3.5-26 3.5-27 3.5-28 3.5-29 3.5-30 3.5-31 3.5-32 3.5-33 3.5-34 3.6-1 3.6-2 3.6-3 3.6-4 3.6-5 3.6-6 3.6-7 3.6-8 3.6-9 3.6-10 3.6-11 3.6-12 3.6-13 3.6-14 3.6-15 3.6-16 3.6-17 3.6-18 3.6-19 3.6-20 3.6-21 3.6-22 3.6-23 3.6-24
- 3. 6-24a 3.6-25 127 127 127 127 127 197 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 182 127 127 127 182 127 127 127 127 127 127 127 127 127 127 127
.127 127 127 127 127 201 201 201 127 03/03/00 03/03/00 03/03/00 03/03/00 03/03/00 07/19/05 03/03/00 03/14/02 03/14/02 07/17/01 03/03/00 12/01/98 04/29/03 12/01/98 04/29/03 12/01/98 02/11/02 12/01/98 04/29/03 07/29/99 04/29/03 06/09/00 04/29/03 10/24/01 12/12/05 12/12/05 12/12/05 04/29/03 05/13/02 05/13/02 05/05/03 05/30/97 07/15/98 07/19/05 07/15/98 07/15/98 07/19/05 Page 9,of 12 Amendment 204 09/19/06
APPENDIX A TO-LICENSE NO.
NPF-1O SAN ONOFRE UNIT 2 TECHNICAL SPECIFICATIONS (NUREG-0741)
LIST OF EFFECTIVE PAGES PaQe No.
Volume Amendment!Date Page No.
Volume Amendment/Date B 3.6-26 3
127 04/29/03 B 3.7-20 3
127 06/02/04 B 3.6-27 3
182 07/11/02 B 3.7-21 3
127 06/02/04 B 3.6-28 3
182 02/11/02 B 3.7-22 3
127 06/02/04 B 3.6-29 3
127 B 3.7-23 3
127 07/29/99 B 3.6-30 3
127 04/29/03 B 3.7-24 3
127 12/14/00 B 3.6-31 3
182 05/02/02 B 3.7-25 3
127 B 3.6-32 3
127 B 3.7-26 3
127 02/28/01 B 3.6-33 3
127 B 3.7-27 3
127 02/28/01 B 3.6-34 3
127 B 3.7-28 3
127 03/03/00 B 3.6-35 3
182 02/11/02 B 3.7-29 3
127 03/03/00 B 3.6-36 3
182 02111/02 B 3.7-30 3
127 03/03/00 B 3.6-37 3
197 07/19/05 B 3.7-31 3
191 11/25/03 B 3.6-38 3
197 07/19/05 B 3.7-32 3
191 11/25/03 B 3.6-39 3
127 10/06/00 B 3.7-33 3
191 11/25/03 B 3.6-40 3
127 10/06/00 B 3.7-34 3
127 03/03/00 B 3.6-41 3
127 10/06/00 B 3.7-35 3
127 07/31/00 B 3.6-42 3
127 04/29/03 B 3.7-36 3
127 0:7/,3-1/00 B 3.6-43 3
127 B 3.7-37 3
127 08/13/01 B 3.6-44 3
127
.B 3.7-38 3
127 08/01/01 B 3.6-45 3
127 B 3.7-39:
3 127 06/23/99 B 3.6-46 3
127 B 3.7-40.
3 127 B 3.6-47 3
127 B 3.7-41 3
127 04/03/06 B 3.6.-48 3
159 10/29/99 B 3.7-42 3
127 B 3.6-49 3
159 10/29/99 B 3.7-43 3
127 B 3,6-50 3
159 10/29/99 B 3.7-43a 3
127 05/29/97 B 3.6-51 3
159 10/29/99 B 3.7-43b 3
127 B 3.6-52 3
159 10/29/99 B 3.7-43c 3
129 B 3.6-53 3
159 10/06/00 B 3.7-43d 3
129 08/09/96 B 3.6-54 3
159 10/06/00 B 3.7-43e 3
129 B 3 6-55 3
159 10/29/99 B 3.7-43f 3
129 B 3.6-56 3
159 10/29/99 B 3.7-43g 3
129 B 3.6-57 3
159 10/29/99 B 3.7-43h 3
129 B 3.7-1 3
212 06/21/07 B 3.7-43i 3
129 B 3.7-2 3
127 08/18/98 B 3.7-43j 3
129 B 3.7-3 3
212 06/21/07 B 3.7-44 3
127 B 3.7-4 3
212 06/21/07 B 3.7-45 3
127 B 3.7-5 3
212 06/21/07 B 3.7-46 3
127 B 3.7-6 3
212 06/21/07 B 3.7-47 3
127.05/30/97 B 3.7-7 3
127 04/16/99 B 3.7-48 3
127 B 3.7-8 3
127 06/23/99 B 3.7-49 3
127 10/17/01 B 3.7-9 3
127 B 3.7-50 3
197 03/07/07 B 3.7-10 3
127 B 3.7-50a 3
197 03107./07 B 3.7-11 3
127 B 3.7-51 3
127 04/08/07 B 3.7-12 3
127 B 3.7-52 3
127 10/17/01 B 3.7-13 3
127 B 3.7-53 3
127 04/12/01 B 3.7-14 3
127 04/16/99 B 3.7-54 3
127 04/12/01 B 3.7-15 3
127 B 3.7-55 3
127 03/07/07 B 3.7-16 3
127 B 3.7-55a 3
127 03/07107 B 3.7-17 3
127 06/02/04 B 3.7-56 3
127 06/28/99 B 3.7-18 3
127 B 3.7-57 3
127 04/25/05 B 3.7-19 3
127 B 3.7-58 3
127 01/13/99 Page 10 of 12 Amendment 212 06/21/07
APPENDIX A TO LICENSE NO.
NPF-1O SAN ONOFRE UNIT 2 TECHNICAL SPECIFICATIONS (NUREG-0741)
LIST OF EFFECTIVE PAGES Page No.
Volume Amendment/Date Page No.
Volume Amendment/Date 3.7-59 3.7-60 3.7-61 3.7-62 3.7-62a 3.7-63 3.7-64 3.7-65 3.7-66 3.7-67 3.7-68 3.7-69 3.7-70 3.7-71 3.7-72 3.7-73 3.7-74 3.7-75 3.7-76 3.7-77 3.7-78 3.7-79 3.8-1 3.8-2 3.8-3 3.8-4 3.8-5 3.8-6 3.8-7 3.8-7a 3.8-8 3.8-9 3.8-10 3.8-11 3.8-12 3.8-13 3.8-14 3.8-15 3.8-16 3.8-17 3.8-18 3.8-19 3.8-20 3.8-21 3.8-22 3.8-23 3.8-24 3.8-25 3.8-26 3.8-27 3.8-28 128 127 128 128 128 208 208 208 208 208 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 127 197 127 127 127 197 127 127 127 127 127 127 127 211 127 127 127 127 127 127 127 127 127 127 02/05/01 08/06/03 09/16/03 02/05/01 02/05/0 1 12/05/06 12/05/06 12/05/06 12/05/06 12/05/06 06/23/99 10/13/98 10/13/98 04/29/03 04/29/03 04/29/03 05/13/02 10/06/99 10/06/999 10/066/99 10/066/99 10/066/99 10/06/99 07/19/05 12/10/99 10/06/-99 10/06/99 07/19/05 10/06/99 10/06/99 10/06/99 10/06/99 10/06/99 06/18/001 06/18/001 04/05/07 06/18/001 06/18/001 06/18/001 06/18/001 06/18/001 06/18/001 06/18/001 06/18/001 06/18/001 06/18/001 3.8-29 3.8-29a 3.8-29b 3.8-29c 3.8-29d 3.8-29e 3.8-29f 3.8-30 3.8-31 3.8-32 3.8-33 3.8-34 3.8-35 3.8-36 3.8-37 3.8-38 3.8-39 3.8-40 3.8-41 3.8-42 3.8-43 3.8-44 3.8-45 3.8-46 3.8-47 3.8-47a 3.8-48 3.8-49 3.8-50 3.8-51 3.8-52 3.8-53 3.8-54 3.8-55 3.8.55a 3.8-56 3.8-57 3.8-58 3.8-59 3.8-60 3.8-61 3.8-62 3.8-63 3.8-64 3.8-65 3.8-66 3.8-67 3.8-68 3.8-69 3.8-70 3
3 3
3 3
3 3
3 3
3 3
3 3
3 3
3 3
3 3
3 3
3 3
3 3
3 3
3
.3 3
3 3
3 3
3 3
3 3
3 3
3 3
3 3
3 3
3 33 3
127 169 169 169 169 169 169 127 127 127 127 175 175 211 127 211 211 127 211 127 127 127 127-127 127 127 127 127 127 127 127 127 127 127 127 127 127 175 175 127 127 127 127 127 127 127 127 127 127 127 06/18/01 06/18/01 06/18/01 06/18/01 06/18/01 06/18/01 06/18/01 12/20/00 12/20/00 04/05/07 01/21/98 04/05/07 04/.05/07 01/21/98 04/05/07 03/25/02 03/25/02 05/03/00 01/22/99 01/22/99 0-1/22/99 01/22/99 08/05/98 08/30/04 08/05/98 12/20/00 12/20/00 07/31/00 Page 11 of 12 Amendment 211 04/05/07
APPENDIX A TO LICENSE NO.
NPF-1O SAN ONOFRE UNIT 2 TECHNICAL SPECIFICATIONS (NUREG-0741)
LIST OF EFFECTIVE PAGES Page No.
Volume Amendment/Date Page No.
Volume Amendment/Date 3.8-71 3.8-72 3.8-73 3.8-74 3.8-75 3.8-76 3.8-77 3.8-78 3.8-79 3.8-80 3.8-81 3.8-82 3.8-83 3.8-84 3.8-85 3.8-86 3.8-87 3.9-1 3.9-2 3.9-3 3.9-4 3.9-5 3.9-6 3.9-7 3.9-8 3.9-9 3.9-10 3.9-11 3.9-12 3.9-13 3.9-13a 3.9-14 3.9-15 3.9-16 3.9-17 3.9-17a 3.9-18 3.9-19 3.9-20 3.9-21 3.9-22 3.9-23 3.9-24 3.9-24a 3.9-25 3.9-26 3.9-27 127 127 175 175 127 127 127 127 127 127 127 127 127 127 127 175 175 127 127 175 127 127 175 127 127 127 193 127 127 193 193 127 127 127 127 127 175 175 127 127 127 127 175 175 127 127 127 12/20/00 12/20/00 01/11/07 12/20/00 12/20/00 12/20/00 12/20/00 12/01/ 98.
02/18/05 10/10/97 10/10/97 02/18/05 02/18/05 10/10/97 10/10/97 07/15/05 04/03/06 07/15/05 12/20/00 05/30/97 07/15/05 04/03/06 12/20/00 12/20/00 05/30/97 10/13/98 10/13/98 Page 12 of 12 Amendment 193 03/07/07 SAN ONOFRE UNIT 2 FACILITY OPERATING LICENSE LIST OF EFFECTIVE PAGES Facility Operating License Page No.
Amendment No.
1 185 2
209 3
212 4
185 5
185 6
185 7
185 8
205 9
185 (3)
SCE, pursuant to the Act and 10 CFR Part 70, to receive, possess, and use at any time special nuclear material as reactor fuel, in accordance with the limitations for storage and amounts required for reactor operation, as described in the Final Safety Analysis Report, as supplemented and amended; (4)
SCE, pursuant to the Act and 10 CFR Parts 30, 40, and 70, to reoeive, possess, and use at any time any byproduct, source and special nuclear material as sealed neutron sources for reactor startup, sealed sources for reactor instrumentation and radiation monitoring equipment calibration, and as fission detectors in amounts as required; (5)
SCE, pursuant to the Act and 10 CFR Parts. 30, 40, and 70, to.
receive, possess, and use in amounts as required any byproduct, source or special nuclear material without restriction to chemical or physical form, for sample analysis or instrument calibration or associated with radioactive apparatus or components; and (6)
SCE, pursuant to the Act and 10 CFR Parts 30, 40, and 70, to possess, but not separate, such byproduct and special nuclear materials as may be produced by the operation of San Onofre Nuclear Generating Station, Units I and 2 and by the decommissioning of San Onofre Nuclear Generating Station-Unit 1.
C.
This license shall be deemed to contain and is subject to the conditions specified in the Commission's regulations set forth in 10 CFR Chapter I and is subject to all applicable provisions of the Act and to the rules, regulations and orders of the Commission now or hereafter in effect; and is subject to the additional conditions specified or incorporated below:
(1)
Maximum Power Level Southern California Edison Company (SCE) is authorized to operate the facility at reactor core power levels not in excess of full power (3438 megawatts thermal).
(2)
Technical Specifications The Technical Specifications contained in Appendix A and the Environmental Protection Plan contained in Appendix B, as revised through Amendment No.
212, are hereby incorporated in the license.
Southern California Edison Company shall operate the facility in accordance with the Technical Specifications and the Environmental Protection Plan.
Amendment No.
212
MSSVs 3.7.1 3.7 PLANT SYSTEMS 3.7.1 Main Steam Safety Valves (MSSVs)
LCO
3.7.1 APPLICABILITY
The MSSVs shall be OPERABLE as specified in Table 3.7.1-1 and Table 3.7.1-2.
MODES 1, 2, and 3.
ACTIONS
NOTE--------------------------------
Separate Condition entry is allowed for each MSSV.
CONDITION REQUIRED ACTION COMPLETION TIME A.
Two to seven required A.1 Reduce power to less 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> MSSVs per SG than or equal to the inoperable.
applicable % RTP listed in Table 3.7.1-1.
AND A.2 Reduce the Linear 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> Power Level High trip setpoint in accordance with Table 3.7.1-1.
B. Required Action and B..1 Be in MODE 3.
6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> associated Completion Time not met.
AND OR B.2 Be in MODE 4.
12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> Eight or more required MSSVs per SG inoperapl e.
SAN ONOFRE--UNIT 2 3.7-1 Amendment No. 212 1
MSSVs 3.7.1 Table 3.7.1-1 (page I of 1)
Maximum Allowable Power Level versus Inoperable MSSVs MAXIMUM MAXIMUMALLOWABLE NUMBER OF INOPERABLE MAXIMUM ALLOWA LER MSSVs PER STEAM GENERATOR LEVEL HIGH TRIP
(% RTP)(%
RTP) 2 95 95 3
56 56 4
46 46 5 to 7 MODE 3 Not applicable SAN ONOFRE--UNIT 2 3.7-3 Amendment No. 212 1
MSSVs 3.7.1 Table 3.7.1-2 (page 1 of Main Steam Safety Valves (Lift 1)
Settings)
VALVE NUMBER LIFT SETTING*
Steam Generator Steam Generator (psig)
- 1
- 2 2PSV-8401 2PSV-8410 1085 2PSV-8402 2PSV-8411 1092 2PSV-8403 2PSV-8412 1099 2PSV-8404 2PSV-8413 1106 2PSV-8405 2PSV-8414 1113 2PSV-8406 2PSV-8415 1120 2PSV-8407 2PSV-8416 1127 2PSV-8408 2PSV-8417 1134 2PSV-8409 2PSV-8418 1140 The lift setting pressure shall correspond to ambient conditions of the valve at nominal operating temperature and pressure.
Each MSSV has an as-found tolerance of +2%/-3%.
Following testing according to Technical Specification 5.5.2.10, MSSVs will be set within +/-l% of the specified lift setpoint.
SAN ONOFRE--UNIT 2 3.7-4 Amendment No. 212 1
MSSVs B 3.7.1 B 3.7 PLANT SYSTEMS B 3.7.1 Main Steam Safety Valves (MSSVs)
BASES BACKGROUND The primary purpose of the MSSVs is to provide overpressure protection for the secondary system.
The MSSVs also provide protection against overpressurizing the reactor coolant pressure boundary by providing a heat sink for the removal of energy from the Reactor Coolant System (RCS) if the preferred heat sink, provided by the Condenser and Circulating Water System, is not available.
Nine MSSVs are located on each main steam header, outside containment, upstream of the main steam isolation valves.
As described in UFSAR Section 10.3.2 (Ref.
1), the MSSVs must have sufficient capacity to limit the secondary system pressure to
- 110% of the design pressure.
This meets the requirements of Section III of the ASME Code (Ref. 2).
The ASME requirement that MSSVs lift settings should be within 1% of the specified setpoint reflects two separate objectives:
the objective to maintain lift setpoints within the bounds of the Safety Analysis and an objective to minimize the number of valves which operate to mitigate an event by staggering the valve setpoints.
This second requirement to stagger setpoints reflects good engineering design, but not safety requirements.
The objective to stagger valve setpoints constrains the less restrictive Safety Analysis requirement as a condition of Operability.
The radiological release assumptions used in the Steam Generator Tube Rupture dose assessment bound the source terms which are based on a low MSSV setpoint of 1100 psia with 15% MSSV blowdown, and considering the appropriate setpoint tolerance.
(continued)
SAN ONOFRE--UNIT 2 B 3.7-1 Amendment No.
212 06/21/07
MSSVs B 3.7.1 BASES (continued)
LCO This LCO requires all MSSVs to be OPERABLE in compliance with Reference 2, even though this is not a requirement of the DBA analysis.
This is because operation with more than one MSSV inoperable per steam generator requires limitations on allowable THERMAL POWER (to meet Reference 2 requirements) and adjustment to Reactor Protection System trip setpoints.
These limitations are according to those shown in Table 3.7.1-1, Required Action A.1, and Required Action A.2.
An MSSV is considered inoperable if it fails to open upon demand.
The OPERABILITY of the MSSVs is defined as the ability to open in accordance with Lift Settings specified in Table 3.7.1-2, relieve Steam Generator overpressure, and reseat when pressure has been reduced.
The OPERABILITY of the MSSVs is determined by periodic surveillance testing in accordance with the inservice testing program.
The Lift Settings specified in Table 3.7.1-2 correspond to ambient conditions of the valve at nominal operating temperature and pressure.
This LCO provides assurance that the MSSVs will perform their designed safety function to mitigate the consequences of accidents that could result in a challenge to the Reactor Coolant Pressure Boundary.
APPLICABILITY In MODE 1, the accident analysis requires a minimum of five MSSVs per Steam Generator which is limiting and bounds all lower MODES.
In MODES 2 and 3, both the ASME Code and the accident analysis require only one MSSV per. Steam Generator to provide overpressure protection.
In MODES 4 and 5, there are no credible transients requiring the MSSVs.
The Steam Generators are not normally used for heat removal in MODES 5 and 6, and thus cannot be overpressurized; there is no requirement for the MSSVs to be OPERABLE in these MODES.
(continued)
SAN ONOFRE--UNIT 2 B 3.7-3 Amendment No. 212 06/21/07
MSSVs B 3.7.1 BASES (continued)
ACTIONS The ACTIONS table is modified by a Note indicating that separate Condition entry is allowed for each MSSV.
A.1 With two to seven MSSVs per steam generator (SG) inoperable reduce power so that the available MSSV relieving capacity meets Reference 2 requirements for the applicable THERMAL POWER.
Operation with less than all nine MSSVs OPERABLE for each Steam Generator is permissible, if THERMAL POWER is limited to the relief capacity of the remaining MSSVs.
This is accomplished by restricting THERMAL POWER so that the energy transfer to the most limiting Steam Generator is not greater than the available relief capacity in that Steam Generator.
Operation at or below the allowable power will ensure the design overpressure limits will not be exceeded.
The 4-hour Completion Time for Required Action A.1 is a reasonable time period to reduce power level and is based on the low probability of an event occurring in this period that would require activation of the MSSVs.
A.2 With two to four MSSVs per SG inoperable, the ceiling on the Linear Power Level-High trip setpoint is reduced.
The reduced reactor trip allowable values are based on a detailed analysis of the Loss of Condenser Vacuum with a Concurrent Single Failure event (Ref.
3).
This analysis considered the concerns identified in NRC Information Notice 94-60 (Ref.
6).
With five to seven MSSVs per SG*inoperable, the plant must be taken to MODE 3 (per Action A.1),
where the Linear Power Level-High trip is not required.
(continued)
SAN ONOFRE--UNIT 2 B 3.7-4 Amendment No. 212 06/21/07
MSSVs B 3.7.1 BASES (continued)
ACTIONS A.2 (continued)
The operator should limit the maximum steady state power level to some value below this setpoint to avoid an inadvertent overpower trip.
The Completion Time of 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> for Required Action A.2 is based on the time required to perform the power reduction, operating experience in resetting all channels of a protective function, and on the low probability of the occurrence of a transient that could result in steam generator overpressure during this period.
B.1 and B.2 If the MSSVs cannot be restored to OPERABLE status in the associated Completion Time, or if one or more Steam Generators have eight or more inoperable MSSVs per SG, the unit must be placed in a MODE in which the LCO does not apply.
To achieve this status, the unit must be placed in at least MODE 3 within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />, and in MODE 4 within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.
The allowed Completion Times are reasonable, based on operating experience, to reach the required unit conditions from full power conditions in an orderlymanner and without challenging unit systems.
SURVEILLANCE SR 3.7.1.1 REQUIREMENTS This SR verifies the OPERABILITY of the MSSVs by the verification of each MSSV lift setpoints in accordance with the inservice testing program.
The ASME Code,Section XI (Ref.
4), requires that safety and relief valve tests be performed in accordance with ASME OM Code, 1998 Edition through 2000 Addenda, Appendix l-Inservice Testing of Pressure Relief Devices in Light-Water Reactor Nuclear Power Plants (Ref.
5).
(continued)
SAN ONOFRE--UNIT 2 B 3.7-5 Amendment No.
212 06/21/07
MSSVs B 3.7.1 BASES (continued)
SURVEILLANCE SR 3.7.1.1 (continued)
REQUIREMENTS According to Reference 5, the following tests are required for MSSVs:
- a.
Visual'examination;
- b.
Seat tightness determination;
- c.
Setpoint pressure determination (lift setting); and
- d.
Compliance with owner's seat tightness criteria.
This SR is modified by a Note that allows entry into and operation in MODE 3 prior to performing the SR.
This is to allow testing of the MSSVs at hot conditions.
The MSSVs may be either bench tested or tested in situ at hot conditions using an assist device to simulate lift pressure.
If the MSSVs are not tested at hot conditions, the lift setting pressure shall be corrected to ambient conditions of the valve at operating temperature and pressure.
REFERENCES
- 1.
- UFSAR, Section 10.3.2.
- 2.
- ASME, Boiler and Pressure Vessel Code,Section III, Article NC-7000, Class 2 Components.
- 3.
- UFSAR, Section 15.2.
- 4.
- ASME, Boiler and Pressure Vessel Code,Section XI, Article IWV-3500.
- 5.
ASME OM Code, 1998 Edition through 2000 Addenda, Appendix l-Inservice Testing of Pressure Relief, Devices in Light-Water Reactor Nuclear Power Plants.
- 6.
SAN ONOFRE--UNIT-2 B 3.7-6 Amendment No.
212 06/21/07
SONGS UNIT 3 SINGLE-SIDED Operating License & Technical Specification/Licensee Controlled Specification AMD 212/204 B06-006 Revise Unit 3 Operating License by removing pages and inserting the enclosed pages.
The revised pages are identified by the captioned amendment number and/or dates and contain marginal/lines indicating the areas of change. Please direct any questions regarding filing of information to: (949) 368-6972or email CDM Controlled Manuals Desk.
REMOVE:
INSERT:
VOLUME 1 VOLUME 1 BEHIND: List of Effective Pages - "Blue Tab" BEHIND: List of Effective Pages - "Blue Tab" List of Effective Pages-Pages 1-12 4/8/07 List of Effective Pages - Pages 1-12 6/21/07 BEHIND: Facility Operating License "Blue Tab" BEHIND: Facility Operating License "Blue Tab" Facility Operating License Page 2 AMD 203 Facility Operating License Page 2 AMD 204 Page 3 AMD 203 Page 3 AMD 204 BEHIND: 3.7 Plant Systems "Blue Tab" BEHIND: 3.7 Plant Systems "Blue Tab" Page 3.7-1 AMD 116 Page 3.7-1 AMD 204 Page 3.7-3 AMD 116 Page 3.7-3 AMD 204 Page 3.7-4 AMD 154 Page 3.7-4 AMD 204 VOLUME 3 VOLUME 3 Page B 3.7-1 AMD 116 8/13/01 Page B 3.7-1 AMD 204 6/21/07 Page B 3.7-3 AMD 116 8/18/98 Page B 3.7-3 AMD 204 6/21/07 age B 3.7-4 AMD 116 No Date Page B 3.7-4 AMD 204 6/21/07 Page B 3.7-5 AMD 116 No Date Page B 3.7-5 AMD 204 6/21/07 Page B 3.7-6 AMD 116 No Date Page B 3.7-6 AMD 204 6/21/07 Filing Instructions Reviewed & Approved:
'YA MJV (e.f2ll /o Signature/NRA Date Sigriature/C-DM Processor Make
/
Page 1 of 1
APPENDIX A TO LICENSE NO. NPF-15 SAN ONOFRE UNIT 3 TECHNICAL SPECIFICATIONS (NUREG-0952)
LIST OF EFFECTIVE PAGES Page No.
Volume Amendment/Date Page No.
Volume Amendment/Date LOEP-I LOEP-2 LOEP-3 LOEP-4 LOEP-4a LOEP-5 LOEP-6 LOEP-7 LOEP-8 LOEP-9 LOEP-10 LOEP-11 LOEP-12 ii iii iv v
vi vii viii 1.1-1 1.1-2 1.1-3 1.1-4 1.*1-5 1.1-6 1.1-7 1.2-1 1.2-2 1.2-3 1.3-1 1.3-2 1.3-3 1.3-4 1.3-5 1.3-6 1.3-7 1.3-8 1.3-9 1.3-10 1.3-11 1.3-12 1.3-13 1.4-1 1.4-2 1.4-3 1.4-4 204 200 204 203 159 199 191 188 200 196 204 203 184 116 200 200 188 116 200 200 116 116 179 196 195 191 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 06/21/07 01/25/07 06/21/07 04/04/07 12/21/06 11/18/05 07/19/05 12/05/06 09/19/06 06/21/07 04/05/07 03/07/07 2.0-1 2.0-2 3.0-1 3.0-2 3.0-3 3.0-4 3.0-5 3.1-1 3.1-2 3.1-3 3.1-4 3.1-5 3.1-6 3.1-7 3.1-8 3.1-9 3.1-10 3.1-11 3.1-12 3.1-13 3.1-14 3.1-15 3.1-16 3.1-17 3.1-18 3.1-19 3.1-20 3.1-21 3.1-22 3.1-23 3.1-24 3.1-25 3.1-26 3.1-27 3.1-28 3.1-29 3.2-1 3.2-2 3.2-3 3.2-4 3.2-5 3.2-6 3.2-7 3.2-8 3.2-9 3.2-10 3.2-11 3.2-12 199 199 116 116 116 177 116 191 191 191 116 116 116 191 191 116 116 126 191 116 191 191 191 116 116 116 116 154 166 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 191 116 116 116 Page 1 of 12 Amendment 204 06/21/07
APPENDIX A TO LICENSE NO.
NPF-15 SAN ONOFRE UNIT 3 TECHNICAL SPECIFICATIONS (NUREG-0952)
LIST OF EFFECTIVE PAGES Page No.
Volume Amendment/Date Page No.
Volume Amendment/Date 3.3-1 1
116 3.3-50 1
116 3.3-2 1
116 3.3-51 1
166 3.3-3 1
116 3.3-52 1
116 3.3-4 1
116 3.4-1 1
141 3.3-5 1
116 3.4-2 1
141 3.3-6 1
139 3.4-3 1
141 3.3-7 1
122 3.4-4 1
116 3.3-8 1
142 3.4-5 1
195 3.3-9 1
142 3.4-6 1
195 3.3-10 1
116 3.4-7 1
195 3.3-11 1
116 3.4-8 1
195 3.3-12 1
122 3.4-9 1
195 3.3-13 1
139 3.4-10 1
195 3.3-14 1
116 3.4-11 1
195 3.3-15 1
116 3.4-12 1
195 3.3-16 1
122 3.4-13 1
116 3.3-17 1
116 3.4-14 1
188 3.3-18 1
116 3.4-15 1
116 3.3-19 1
116 3.4-16 1
166 3.3-20 1
122 3.4-17 1
.166 3.3-21 1
116 3.4-18 1
195 3.3-22 1
148 3.4-19 1
166 3.3-23 1
148 3.4-20 1
116 3.3-24 1
148 3.4-21 1
166 3'3-25 1
148 3.4-22 1
195 3.3-26 1
116 3.4-23 1
166 3.3-27 1
116 3.4-24 1
166 3.3-28 1
116 3.4-25 1
166 3.3-29 1
122 3.4-26 1
152 3.3-30 1
116 3.4-27 1
146 3.3-31 1
116 3.4-28 1
147 3.3-32 1
116 3%,4-,29, 1
147 3.3-33 1
116 3.4-30 1
195 3.3-34 1
187 3.4-31 1
195 3.3-35 1
121 3.4-32 1
116 3.3-36 1
121 3.4-33 1
195 3.3-37 1
121 3.4-34 1
134 3.3-38 1
121 3.4-35 1
195 3.3-39 1
121 3.4-36 1
116 3.3-40 1
166 3.4-37 1
196 3.3-41 1
151 3.4-38 1
196 3.3-42 1
200 01/25/07 3.4-39 1
116 3.3-43 1
200 01/25/07 3.4-40 1
116 3.3-44 1
116 3.4-41 1
116 3.3-45 1
185 3.4-42 1
116 3.3-46 1
185 3.4-43 1
116 3.3-47 1
185 3.4-44 1
116 3.3-48 1
116 3.4-45 1
116 3.3-49 1
116 Page 2 of 12 Amendment 200 01/25/07
APPENDIX A TO LICENSE NO.
NPF-15 SAN ONOFRE UNIT 3 TECHNICAL SPECIFICATIONS (NUREG-0952)
LIST OF EFFECTIVE PAGES Page No.
Volume Amendment/Date Page No.
Volume Amendment/Date 3.4-46 3.4-47 3.4-48 3.4-49 3.4-50 3.4-51 3.4-52 3.5-1 3.5-2 3.5-3 3.5-4 3.5-5 3.5-6 3.5-7.
3.5-8 3.5-9 3.5-10 3.5-11 3.6-1 3.6-2 3.6-3 3.6-4 3.6-5 3.6-6 3.6-7 3.6-8 3.6,-9 3.6-10 3.6-11 3.6-12 3.6-13 3.6-14 3.6-15 3.6-16 3.6-17 3.6-18 3.6-19 3.6-20 3.6-21 3.6-22 3.6-23 3.6-24 3.6-25 3.6-26 3.7-1 3.7-2 3.7-3 3.7-4 3.7-5 11 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1
.1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 I*
1 1
1 1
1 1
1 116 116 116 116 116 196 196 131 124 116 131 116 181 116 116 116 116 116 116 135 116 116 116 135 116 116 116 116 116 156 192 192 116 116 116 162 116 116 116 116 150 150 116 116 204 116 204 204 116 3.7-6 3.7-7 3.7-8 3.7-9 3.7-10 3.7-11 3.7-12 3.7-13 3.7-14 3.7-15 3.7-16 3.7-17 3.7-18 3.7-19 3.7-19a 3.7-19b 3.7-19c 3.7-20 3.7-21 3.7-22 3.7-23 3.7-24 3.7-25 3.7-26, 3.7-27 3.7-28 3.7-29 3.7-30 3.7-31 3.7-32 3.7-33 3.7-34 3.7-35 3.8-1 3.8-2 3.8-3 3.8-4 3.8-5 3.8-6 3.8-7 3.8-8 3.8-9 3.8-10 3.8-11 3.8-12 3.8-13 3.8-14 3.8-15 3.8-16 116 116 116 116 116 155 116 116 182 139 153 116 116 116 118 118 118 116 116 172 116 172 168 168 200 200 116 116 116 120 120 120 116 133 133 116 149 170 203 149 170 149 149 149 149 160 170 149 116 01/25/07 01/25/07 Page 3 of 12 Amendment 204 06/21/07
APPENDIX A TO LICENSE NO.
NPF-15 SAN ONOFRE UNIT 3 TECHNICAL SPECIFICATIONS (NUREG-0952)
LIST OF EFFECTIVE PAGES Page No.
Volume Amendment/Date Page No.
Volume Amendment/Date 3.8-17 3.8-18 3.8-19 3.8-20 3.8-21 3.8-22 3.8-23 3.8-24 3.8-25 3.8-26 3.8-27 3.8-28 3.8-29 3.8-30 3.8-31 3.8-32 3.8-33 3.8-34 3.8-35 3.8-36 3.8-37 3.8-38 3.8-39 3.8-40 3.8-41 3.9-1 3.9-2 3.9-3 3.9-4 3.9-5 3.9-6 3.9-6a 3.9-7 3.9-8 3.9-9 3.9-9a 3.9-10 4.0-1 4.0-2 4.0-3 4.0-4 4.0-5 5.0-1 5.0-2 5.0-3 5.0-4 5.0-5 5.0-6 5.0-7 116 166 116 203 203 116 116 116 116 116 166 116 116 116 116 116 116 116 116 166 116 116 116 166 116 116 166 116 184 116 166 166 144 144 166 144 123 190 116 116 120 120 199 199 199 199 199 175 116 5.0-8 5.0-9 5.0-10 5.0-11 5.0-12 5.0-13 5.0-14 5.0-15 5.0-15a 5.0-16 5.0-17 5.0-18 5.0-19 5.0-20 5.0-20a 5.0-20b 5.0-21 5.0-22 5.0-23 5.0-24 5.0-25 5.0-26 5.0-27 5.0-27a 5.0-28 5.0-29 5.0-30 5.0-31 199 169 116 161 169 196 196 198 198 196 200 196 196 196 189 135 116 116 186 116 116 191 195 195 196 196 188 199 Page 4 of 12 Amendment 203 04/04/07
APPENDIX A TO LICENSE NO.
NPF-15 SAN ONOFRE UNIT 3 TECHNICAL SPECIFICATIONS (NUREG-0952)
LIST OF EFFECTIVE PAGES Paqe No.
Bibliographic Data Sheet Appendix B Environmental Protection Plan Vol ume Amendment/Date 1-1 2-1 2-2 3-1 3-2 4-1 4-2 Appendix C Page 2 Page '.3 1
1 1
1 1
1 1
1 1
1 dated dated dated dated dated dated Nov.
15, Nov.
15, Nov.
15, Nov.
15, Nov.
15, Nov.
15, 159 159 Nov.
15, Nov.
15, Nov.
15, Nov.
15, 1982 1982 1982 1982 1982 1982 1982 1982 1982 1982 dated dated dated dated Page 4a of 12 Amendment 159
APPENDIX A TO LICENSE NO.
NPF-15 SAN ONOFRE UNIT 3 TECHNICAL SPECIFICATIONS (NUREG-0952)
LIST OF EFFECTIVE PAGES Page No.
Volume Amendment/Date Page No.
Volume Amendment/Date B 2.0-1 2
183 07/19/04 B 3.1-27 2
116 B 2.0-2 2
116 B 3.1-28 2
191 11/18/05 B 2.0-3 2
199 12/21/06 B 3.IN29 2
191 11/18/05 B 2.0-3a 2
183 07/19/04 B 3.1-30 2
191 11/18/05 B 2.0-4 2
199 12/21/06 B 3.1-31 2
116 B 2.0-5 2
199 12/21/06 B 3.1-32 2
116 05/02/97 B 2.0-6 2
116 B 3.1-33 2
116 B 2.0-7 2
116 B 3.1-34 2
116 05/02/97 B 2.0-8 2
199 12/21/06 B 3.1-35 2
116 B 2.0-9 2
199 12/21/06 B 3.1-36 2
116 B 3.0-1 2
116 B 3.1-37 2
191 11/18/05 B 3.0-2 2
116 B 3.1-38 2-191 11/18/05 B 3.0-3 2
116 B 3.1-39 2
116 B 3.0-4 2
- 199, 12/21/06 B 3.1-40 2
116 B 3.0-5 2
116 B 3.1-41 2
116 B 3.0-6 2
116 B 3.1-42 2
116 B 3.0-7 2
116 B 3.1-43 2
191 1i/18/05 B 3.0-8 2
116 B 3.1-43a 2
191 11/18/05 B 3.0-9 2
116 B 3.1-44 2
191 11/18/05 B 3.0-10 2
116 B 3.1-45 2
116 B 3.0-11 2
116 B 3.1-46 2
191 11/18/05 B 3.0-12 2
116 12/01/98 B 3.1-47 2
116 B 3.0-13 2
177 10/25/02 B 3.1-48 2
116 B 3.0-14 2
177 05/08/02 B 3.1-49 2
116 B 3.0-15 2
177 05/08/02 B 3.1-50 2
116 B 3:.1i1' 2
191 11/18/05 B 3.1-51 2
116 B 3.1-2 2
191 11/18/05 B 3.1-52 2
116 B 3.1-3 2
191 11/18/05 B 3.1-53 2
116 B 3.1-4 2
191 11/18/05 B 3.1-54 2
116 08/03/01 B 3.1-5 2
Deleted B 3.1-55 2
116 08/03/01 B 3.1-6 2
Deleted B 3.1-56 2
116 08/03/01 B 3.1-7 2
191 11/18/05 B 3.1-57 2
116 08/03/01 B 3.1-8 2
191 11/18/05 B 3.1-58 2
116 08/03/01 B 3.1-9 2
191 11/18/05 B 3.1-58a 2
116 08/03/01 B 3.1-10 2
191 11/18/05 B 3.1-58b 2
116 08/03/01 B 3.1-11 2
Deleted B 3.1-59 2
191 11/18/05 B 3.1-12 2
Deleted B 3.1-60 2
116 11/05/96 B 3.1-13 2
116 B 3.1-61 2
116 05/03/00 B 3.1-14 2
116 B 3.1-62 2
166 12/20/00 B 3.1-15 2
191 11/18/05 B 3.1-63 2
166 05/21/02 B 3.1-16 2
116 B 3.1-63a 2
166 12/20/00 B 3.1-17 2
191 11/18/05 B 3.1-64 2
116 B 3.1-18 2
116 B 3.1-65 2
116 B 3.1-19 2
116 01/03/02 B 3.1-66 2
116 B 3.1-20 2
116 B 3.1-67 2
116 B 3.1-21 2
116 01/03/02 B 3.1-68 2
116 B 3.1-22 2
116 05/30/97 B 3.1-69 2
116 B 3.1-23 2
116 B 3.1-70 2
116 B 3.1-24 2
116 B 3.1-71 2
116 B 3.1-25 2
116 05/02/97 B 3.1-72 2
116 B 3.1-26 2
116 07/29/99 Page 5 of 12 Amendment 199 12/21/06
APPENDIX A TO LICENSE NO.
NPF-15 SAN ONOFRE UNIT 3 TECHNICAL SPECIFICATIONS (NUREG-0952)
LIST OF EFFECTIVE PAGES Page No.
Volume Amendment/Date Page No.
Volume Amendment/Date 3.1-73 3.1-74 3.1-75 3.1-76 3.1-77 3.1-78 3.1-79 3.1-80 3.2-1 3.2-2 3.2-3 3.2-4 3.2-5 3.2-6 3.2-7 3.2-8 3.2-9 3.2-10 3.2-11 3.2-12 3.2-13 3.2-14 3.2-15 3.2-16 3.2-17 3,
- 2-18 3.2-19 3.2-20 3.2-21 3.2-22 3.2-23 3.2-24 3.2-25 3.2-26 3.2-27 3.2-28 3.2-29 3.2-30 3.2-31 3.2-32 3.2-33 3.2-34 3.2-35 3.2-36 3.2-37 3.2-38 3.2-39 3.2-40 3.2-41 3.3-1 116 116 116 116 116 116 116 116 116 116 116 183 116 116 116 116 116 116 116 183 116 116 116 116 116 116 183 116 116 116 116 116 116 116 116 116 183 191 116 116 116 116 116 116 116 183 116 116 116 116 05/29/97 05/29/97 07/19/04 07/19/04 07/19/04 07/19/04 11/18/05 07/19/04 B
B B
B B
B B
B B
B B
B B
B B
B B
B B
B B
B B
B B
B B
B B
B B
B B
B B
B B
B B
B B
B B
B B
B B
B B
B 3.3-2 3.3-3 3.3-4 3.3-5 3.3-6 3.3-7 3.3-8 3.3-9 3.3-10 3.3-11 3.3-12 3.3-13 3.3-14 3.3-15 3.3-16 3.3-17 3.3-18 3.3-19 3.3-20 3.3-21 3.3-22 3.3-23 3.3-24 3.3-25 3.3-26 3.3-26a 3.3-27 3.3-28 3.3-29 3.3-30 3.3-31 3.3-32 3.3-33 3.3-34 3.3-35 3.3-36 3.3-37 3.3-37a 3.3-38 3.3-39 3.3-40 3.3-41 3.3-42 3.3-43 3.3-44 3.3-45 3.3-46 3.3-47 3.3-48 3.3-49 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 179 179 116 116 116 116 116 116 116 116 116 116 116 116 07/17/97 03/12/99
.07/17/97 09/16/03 03/12/99
.03/12/99 03/12/99
- 03/12/99 12/30/96 12/30/96 12/30/96 05/29/97 05/02/97 03/12/99 03/12/99 03/12/99 03/12/99 03/12/99 09/16/03 07/17/97 12/09/98 12/09/98 12/30/96 12/30/96 12/30/96 12/30/96 09/18/98 09/18/98 Page 6 of 12 Amendment 191 11/18/05
APPENDIX A TO LICENSE NO.
NPF-15 SAN ONOFRE UNIT 3 TECHNICAL SPECIFICATIONS (NUREG-0952)
LIST OF EFFECTIVE PAGES Paqe No.
Volume Amendment/Date Page No.
Volume Amendment!Date 3.3-50 3.3-51 3.3-51a 3.3-52 3.3-53 3.3-54 3.3-55 3.3-56 3.3-57 3.3-58 3.3-59 3.3-60 3.3-61 3.3-62 3.3-63 3.3-64 3.3-65 3.3-66 3.3-67 3.3-68 3.3-69 3.3-70 3.3-71 3.3-72 3.3-73 3.3-75 3.3-76 3.3-77 3.3-78 3.3-79 3.3-80 3.3-81 3.3-82 3.3-83 3.3-84 3.3-85 3.3-86 3.3-87 3.3-88 3.3-89 3.3-90 3.3-91 3.3-92 3.3-93 3.3-94 3.3-95 3.3-96 3.3-97 3.3-98 3.3-99 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 09/18/98 02/11/02 09/18/98 07/17/97 09/18/98 09/18/98 09/18/98 07/17/97 12/30/96 12/30/96 12/30/96 05/28/97 12/30/96 07/17/97 02/24/99 07/17/97 10/06/99 10/06/99 10/06/99 07/18/01 10/06/99 B
B B
B B
B B
B B
B B
B B
B B
B B
B B
B B
B B
B B
B B
B B
B B
B B
B B
B B
B B
B B
B B
B B
B B
B B
B 3.3-100 3.3-101 3.3-102 3.3-103 3.3-103a 3.3-103b 3.3-103c 3.3-104 3.3-105
- 3. 3-106 3.3-107 3.3-108
- 3. 3-109 3.3-110 3.3-111 3.3-112 3.3-113 3.3-114 3.3-115 3.3-116 3.3-117 3.3-118 3.3-119 3.3-120 3.3-121 3.3-122 3.3-123 3.3-124 3.3-125 3.3-126 3.3-127 3.3-128 3.3-129 3.3-130 3.3-131 3.3-132 3.3-133 3.3-134 3.3-135 3.3-136 3.3-137 3.3-138 3.3-139 3.3-140 3.3-141 3.3-142 3.3-143 3.3-144 3.3-145 3.3-146 188 116 116 116 179 148 179 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 165 116 116 116 116 116 116 116 116 116 116 116 116 07/19/05 10/06/99 10/06/99 10/06/99 09/16/03 12/30/96 12/30/96 12/30/96 12/30/96 05/28/97
- 05/28/97 05/28/97 09/06/00 09/06/00 05/29/97 07/13/99 12/14/00 05/28/97 06/09/00 05/28/97 05/28/97 05/28/97 05/28/97 05/28/97 05/28/97 05/28/97 05/28/97 06/27/97 03/19/98 Page 7 of 12 Amendment 188 07/19/05
APPENDIX A TO LICENSE NO.
NPF-15 SAN ONOFRE UNIT 3 TECHNICAL SPECIFICATIONS (NUREG-0952)
LIST OF EFFECTIVE PAGES Page No.
Volume Amendment/Date Page No.
Volume Amendment/Date 3.3-147 3.3-148 3.3-149 3.3-150 3.3-151 3.3-152 3.3-153 3.3-154 3.3-155 3.3-156 3.3-157 3.3-158 3.3-159 3.3-160 3.3-161 3.3-162 3.3-163 3.3-164 3.3-165 3.3-166 3.3-167 3.3-168 3.3-169 3.3-170 3.3-171 3.3-=.172 3.3-173 3.3-174 3.3-175 3.3-176 3.3-177 3.3-178 3.3-179 3.3-180 3.3-181 3.3-'182 3.3-183 3.3-184 3.3-185 3.4-1 3.4-2 3.4-3 3.4-4 3.4-5 3.4-6 3.4-7 3.4-8 3.4-9 3.4-10 3.4-11 116 166 166 116 116 200 200 200 200 200 200 116 116 116 116 116 119 116 116 185 116 116 116 116 185 185 116 116 116 116 116 116 116 116 116 166 166 166 166 116 116 116 116 116 116 116 116 195 116 116 06/27/97 12/20/00 12/20/00 08/20/01 06/27/97 12/05/06 12/05/06 12/05/06 12/05/06 12/05/06 12/05/06 12/17/98 06/08/00 06/23/99 05/30/97 05/30/97 05/30/97 05/30/97 05/30/97 04/25/05 05/30/97 12/02/99 05/30/97 04/25/05 04/25/05 05/30/97 05/30/97 03/06/06 10/30/98 10/30/98 04/24/01 04/24/01 07/29/96 12/20/00 12/20/00 12/20/00 12/20/00 02/24/99 02/24/99 02/24/99 3.4-12 3.4-13 3.4-14 3.4-15 3.4-16 3.4-17 3.4-18 3.4-19 3.4-20 3.4-21 3.4-22 3.4-23 3.4-24 3.4-25 3.4-26 3.4-27 3.4-28 3.4-29 3.4-30 3.4-31 3.4-32 3.4-33 3.4-34 3.4-35 3.4-36&
3.4-37 3.4-38' 3.4-38a 3.4-39 3.4-40 3.4-41 3.4-42 3.4-43 3.4-44 3.4-45 3.4-46 3.4-47 3.4-48 3.4-49 3.4-50 3.4-51 3.4-52 3.4-53 3.4-54 3.4-55 3.4-56 3.4-57 3.4-58 3.4-59 3.4-60 3
3 3
3 3
3 3
3 3
3 3
3 3
3 3
3 3
3 3
3 3
3 3
3 3
'3
.3 3
3
.3 3
3 3
3 3
3 3
3 3
3 3
3 3
3 3
3 3
3 33 116 116 116 195 195 188 188 116 188 188 116 116 196 116 116 116 196 166 166 116 196 116 166 166 116 166 166 166 196 166 116 116 166 166 166 116 146 152 116 116 147 147 147 147 195 195 195 195 195 195 07/19/05 07/19/05 07/19/05 07/19/05 i12/20/00 12/20/00 12/20/00
.12/20/00 12/20/00 07/15/05 04/03/06 12/20/00 12/20/00 04/03/06 12/20/00 05/30/00 05/30/00 05/15/02 05/30/00 05/30/00 03/22/01 03/22/01 03/22/01 04/27/05 Page 8 of 12 Amendment 200 12/05/06
APPENDIX A TO LICENSE NO. NPF-15 SAN ONOFRE UNIT 3 TECHNICAL SPECIFICATIONS (NUREG-0952)
LIST OF EFFECTIVE PAGES Page No.
Volume Amendment/Date Page No.
Volume Amendment/Date B 3.4-61 3
195 B 3.5-11 3
116 03/03/00 B 3.4-62 3
195 B 3.5-12 3
116 03/03/00 B 3.4-63 3
195 B 3.5-13 3
116 03/03/00 B 3.4-64 3
195 B 3.5-14 3
116 03/03/00 B 3.4-65 3
195 B 3.5-15 3
116 03/03/00 B 3.4-66 3
195 B 3.5-16 3
188 07/19/05 B 3.4-67 3
195 B 3.5-17 3
116 03/03/00 B 3.4-68 3
195 B 3.5-18 3
116 03/14/02 B 3.4-69 3
195 B 3.5-19 3
116 03/14/02 B 3.4-70 3
116 B 3.5-20 3
116 07/17/01 B 3.4-71 3
196 B 3.5-20a 3
116 03/03/00 B 3.4-72 3
196 B 3.5-21 3
116 B 3.4-73 3
196 B 3.5-22 3
116 B 3.4-74 3
196 B 3.5-23 3
116 B 3.4-75 3
196 B 3.5-24 3
116 B 3.4-76 3
116 B 3.5-25 3
116 B 3.4-77 3
116 B 3.5-26 3
116 B 3.4-78 3
116 B 3.5-27 3
116 B 3.4-79 3
116 B 3.5-28 3
116 B 3.4-80 3
116 09/06/00 B 3.5-29 3
116 B 3.4-81 3
116 09/06/00 B3.5-30 3
116 B 3.4-82 3
116 B 3.5-31 3
116 B 3.4-83 3
116 B 3.5-32 3
116 B 3.4-84 3
116 B 3.5-33 3
116 B 3.4-85 3
116 B 3.5-34 3
116 B 3.4-86 3
116 B 3.6-1 3
116 12/01/98 B 3.4-87 3
116 B 3.6-2 3
173 08/06/03 B 3.4-88 3
116 05/13/02 B 3.6-3' 3
116 08/06/03 B 3.4-89 3
116 05/13/02 B 3.6-4 3
116 04/29/03 B 3.4-90 3
116 B 3.6-5 3
116 12/01/98 B 3.4-91 3
116 B 3.6-6 3
173 02/11/02 B 3.4-92 3
116 B 3.6-7 3
116 B 3.4-93 3
196 B 3.6-8 3
116 B 3.4-94 3
196 B 3.6-9 3
116 B 3.4-95 3
196 B 3.6-10 3
116 B 3.4-96 3
196 B 3.6-11 3
116 12/01/98 B 3.4-97 3
196 B 3.6-12 3
116 04/29/03 B 3.4-98 3
196 B 3.6-13 3
116 07/29/99 B 3.4-99 3
196 B 3.6-14 3
116 B 3.4-100 3
196 B 3.6-15 3
116 B 3.5-1 3
116 B 3.6-16 3
116 04/29/03 B 3.5-2 3
116 B 3.6-17 3
116 B 3.5-3 3
116 B 3.6-18 3
116 06/09/00 B 3.5-4 3
116 05/05/03 B 3.6-19 3
116 B 3.5-5 3
116 05/30/97 B 3.6-20 3
116 B 3.5-6 3
116 B 3.6-21 3
116 04/29/03 B 3.5-7 3
116 07/15/98 B 3.6-22 3
116 10/24/01 B 3.5-8 3
188 07/19/05 B 3.6-23 3
192 12/12/05 B 3.5-9 3
116 07/15/98 B 3.6-24 3
192 12/12/05 B 3.5-10 3
116 07/15/98 B 3.6-24a 3
192 12/12/05 B 3.5-10a 3
188 07/19/05 B 3.6-25 3
116 04/29/03 Page 9 of 12 Amendment 196 09/19/06
APPENDIX A TO LICENSE NO.
NPF-15 SAN ONOFRE UNIT 3 TECHNICAL SPECIFICATIONS (NUREG-0952)
LIST OF EFFECTIVE PAGES Page No.
Volume Amendment/Date Page No.
Volume Amendment/Date 3.6-26 3.6-27 3.6-28 3.6-29 3.6-30 3.6-31 3.6-32 3.6-33 3.6-34 3.6-35 3.6-36 3.6-37 3.6-38 3.6-39 3.6-40 3.6-41 3.6-42 3.6-43 3.6-44 3.6-45 3.6-46 3.6-47 3.6-48 3.6-49 3.6-50 3.6-51 3.6-52 3.6-53 3.6-54 3.6-55 3.6-56 3.6-57 3.7-1 3.7-2 3.7-3 3.7-4 3.7-5 3.7-6 3.7-7 3.7-8 3.7-9 3.7-10 3.7-11 3.7-12 3.7-13 3.7-14 3.7-15 3.7-16 3.7-17 3.7-18 3.7-19 116 173 173 116 116 173 116 116 116 173 173 188 188 116 116 116 116 116 116 116 116 116 150 150 150 150 150 150 150 150 150 150 204 116 204 204 204 204 116 116 116 116 116 116 116 116 116 116 116 116 116 04/29/03 07/11/02 02/11/02 04/29/03 05/02/02 02/11/02 02/11/02 07/19/05 07/19/05 10/06/00 10/06/00 10/06/00 04/29/03 10/29/99 10/29/99 10/29/99 10/29/99 10/29/99 10/06/0.0 10/06/00 10/29/99 10/29/99 10/29/99 06/21/07 08/18/98 06/21/07 06/21/07 06/21/07 06/21/07 04/16/99 06/23/99 3.7-20 3.7-21 3.7-22 3.7-23 3.7-24 3.7-25 3.7-26 3.7-27 3.7-28 3.7-29 3.7-30 3.7-31 3.7-32 3.7-33 3.7-34 3.7-35 3.7-36 3.7-37 3.7-38 3.7-39 3.7-40 3.7-41 3.7-42 3.7-43 3.7-43a 3.7-43b 3.7-43c 3.7-43d 3.7-43e 3.7-43f 3.7-43g 3.7-43h 3.7-43i 3.7-43j 3.7-44 3.7-45 3.7-46 3.7-47 3.7-48 3.7-49 3.7-50 3.7-50a 3.7-51 3.7-52 3.7-53 3.7-54 3.7-55 3.7-55a 3.7-56 3.7-57 3.7-58 116 116 116 116 116 116 116 116 116 116 116 182 182 182 116 116 116 116 116 116 116 116 116 116 116 116 118 118 118 118 118 118 118 118 116 116 116 116 116 116 188 188 116 116 116 116 116 116 116 116 116 06/02/04 06/02/04 06/02/04 01/05/01 12/14/00 02/28/01 02/28/01 03/03/00 03/03/00 03/03/00 11/25/03 11/25/03 11/25/03 03/03/00 03/02/01 07/31/00 08/13/01 08/01/01 06/23/99 04/03/06 05/29/97 07/29/96 05/30/97 10/17/01 03/07/07 03/07/07 04/08/07 10/17/01 04/12/01 04/12/01 03/07/07 03/07/07 06/28/99 04/25/05 03/19/98 04/16/99 06/02/04 Page 10 of 12 Amendment 204 06/21/07
APPENDIX A TO LICENSE NO. NPF-15 SAN ONOFRE UNIT 3 TECHNICAL SPECIFICATIONS (NUREG-0952)
LIST OF EFFECTIVE PAGES Page No.
Volume Amendment/Date Page No.
Volume Amendment/Date 3.7-59 3.7-60 3.7-61 3.7-62 3.7-62a 3.7-63 3.7-64 3.7-65 3.7-66 3.7-67 3.7-68 3.7-69 3.7-70 3.7-71 3.7-72 3.7-73 3.7-74 3.7-75 3.7-76 3,7-77 3.7-78 3-7-79 3'.8-1 3.8-2 3.8-3 3-.8-4 3.8-3.8-6 3.8-7 3.8-7a 3.8-8 3.8-9 3.8-10 3.8-11 3.8-12 3.8-13 3.8-14 3.8-15 3.8-16 3.8-17 3.8-18 3.8-19 3.8-20 3.8-21 3.8-22 3.8-23 3.8-24 3.8-25 3.8-26 3.8-27 3.8-28 3
3 3
3 3
3 3
3 3
3 3
3 3
3 3
3 3
3 3
3 3
3 3
3 3
3 3
3 3
3 3
3 3
3 3
3 3
3 3
3 3
3 3
3 3
3 3
3 3
33 117 116 117 117 117 200 200 200 200 200 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 188 116 116 116 188 116 116 116 116 116 116 116 203 116 116 116 116 116 116 116 116 116 116 02/05/01 10/17/01 09/16/03 02/05/01 02/05/01 12/05/06 12/05/06 12/05/06 12/05/06 12/05/06 10/13/98 10/13/98 10/13/98 04/29/03 04/29/03 04/29/03 05/13/02 10/06/99 10/06/99
.10/06/99 10/06/99 10/06/99 10/06/99 07/19/05 12/10/99 10/06/99 10/06/99 07/19/05 10/06/99 10/06/99 10/06/99 10/06/99 10/06/99 06/18/01 06/18/01 04/05/07 06/18/01 06/18/01 06/18/01 06/18/01 06/18/01 06/18/01 06/18/01 06/18/01 06/18/01 06/18/01 3.8-29 3.8-29a 3.8-29b 3.8-29c 3-8-29d 3.8-29e 3.8-29f 3.8-30 3.8-31 3.8-32 3.8-33 3.8-34 3.8-35 3.8-36 3.8-37 3.8-38 3.8-39 3.8-40 3.8-41 3.8-42 3.8-43 3.8-44 3.8-45 3.8-46 3.8-47 3.8-47a 3.8-48 3.8-49 3.8-50 3.8-51 3.8-52 3.8-53 3.8-54 3.8-55 3.8-55a 3.8-56 3.8-57 3.8-58 3.8-59 3.8-60 3.8-61 3.8-62 3.8-63 3.8-64 3.8-65 3.8-66 3.8-67 3.8-68 3.8-69 3.8-70 3.8-71 116 160 160 160 160 160 160 116 116 116 116 166 166 203 116 203 203 116 203 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 116 166 166 116 116 116 116 116 116 116 116 116 116 116 116 06/18/01 06/18/01 06/18/01 06/18/01 06/18/01 06/18/01 06/18/01 12/20/00 12/20/00 04/05/07 01/2-1/98 04/05/07 04/05/07 01/21/98 04/05/07 03/25/02 03/25/02 05/03/00 I01/22/99 01/22/99 01/22/99 01/22/99 08/05/98 08/30/04 08/05/98 12/20/00 12/20/00 07/31/00 Page 11 of 12 Amendment 203 04/05/07
APPENDIX A TO LICENSE NO.
NPF-15 SAN ONOFRE UNIT 3 TECHNICAL SPECIFICATIONS (NUREG-0952)
LIST OF EFFECTIVE PAGES Page No.
Volume Amendment/Date Page No.
Volume Amendment/Date 3.8-72 3.8-73 3.8-74 3.8-75 3.8-76 3.8-77 3.8-78 3.8-79 3.8-80 3.8-81 3.8-82 3.8-83 3.8-84 3.8-85 3.8-86 3.8-87 3.9-1 3.9-2 3.9-3 3.9-4 3.9-5 3.9-6 3.9-7 3.9-8 3.9-9 3.9-10 3.9-11 3.9-12 3.9-13 3.9-13a 3.9-14 3.9-15 3.9-16 3.9-17a 3.9-17a 3.9-18 3.9-19 3.9-20 3.9-21 3.9-22 3.9-23 3.9-24 3.9-24a 3.9-25 3.9-26 3.9-27 116 166 166 116 116 116 116 116 116 116 116 116 116 116 166 166 116 116 166 116 116 166 116 116 116 184 116 116 184 184 116 116 116 116 116 166 166 116 116 116 116 166 166 116 116 116 12/20/00 12/20/00 01/11/07 12/20/00 12/20/00 12/20/00 12/20/00 12/01/98 02/18/05 10/10/97 10/10/97 02/18/05 02/18/05 10/10/97 10/10/97 07/15/05 04/03/06 07/15/05 12/20/00 05/30/97 07/15/05 04/03/06 12/20/00 12/20/00 05/30/97 10/13/98 10/13/98 Page 12 of 12 Amendment 184 03/07/07 SAN ONOFRE UNIT 3 FACILITY OPERATING LICENSE LIST OF EFFECTIVE PAGES Facility Operating License Page No.
Amendment No.
I 2
.3 4
5 6
7 8
176 201 204 176.
176 176 197 176 (3)
SCE, pursuant to the Act and 10 CFR Part 70, to receive, possess, and use at any time special nuclear material as reactor fuel, in accordance with the limitations for storage and amounts required for reactor operation, as described in the Final Safety Analysis Report, as supplemented and amended; (4)
SCE, pursuant to the Act and 10 CFR Parts 30, 40, and 70, to receive, possess, and use at any time any byproduct, source and special nuclear materials as sealed neutron sources for reactor startup, sealed sources for reactor instrumentation and radiation monitoring equipment calibration, and as fission detectors in amounts as required; (5)
SCE, pursuant to the Act and 10 CFR Parts 30, 40, and 70 to receive, possess, and use in amounts as required any byproduct, source or special nuclear material without restriction to.chemical or physical form, for sample analysis or instrument calibration or associated with radioactive apparatus or components; and (6)
SCE, pursuant to the Act and 10 CFR Parts 30, 40, and 70, to possess, but not separate, such byproduct and special nuclear materials as may be produced by the operation of San Onofre Nuclear Generating Station, Units 1 and 3 and by the decommissioning of San Onofre Nuclear Generating Station Unit 1.
C.
This license shall be deemed to contain and is subject to the conditions specified in the Commission's regulations set forth in 10 CFR Chapter I and is subject to all applicable provisions of the Act and to the rules, regulations and orders of the Commission now or hereafter in effect; and is subject to the additional conditions specified or incorporated below:
(1) Maximum Power Level Southern California Edison Company (SCE) is authorized to operate the facility at reactor core power levels not in excess of full power (3438 megawatts thermal).
(2)
Technical Specifications The Technical Specifications contained in Appendix A and the Environmental Protection Plan contained in Appendix B, as revised through Amendment No.
204, are hereby incorporated in -the license.
Southern California Edison Company shall operate the facility in accordance with the Technical Specifications and the Environmental Protection Plan.
Amendment No. 204
MSSVs 3.7.1 3.7 PLANT SYSTEMS 3.7.1 Main Steam Safety Valves (MSSVs)
LCO
3.7.1 APPLICABILITY
The MSSVs shall be OPERABLE as specified in Table 3.7.1-1 and Table 3.7.1-2.
MODES 1, 2, and 3.
ACTIONS
NOTE Separate Condition entry is allowed for each MSSV.
CONDITION REQUIRED ACTION COMPLETION TIME A.
Two to seven required A.1 Reduce power to less 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> MSSVs per SG than or equal to the inoperable.
applicable % RTP listed in Table 3.7.1-1.
AND A.2 Reduce the Linear 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> Power Level High trip setpoint in accordance with Table 3.7.1-1.
B. Required Action and B.1 Be in MODE 3.
6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> associated Completion Time not met.
AND OR B.2 Be in MODE 4.
12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> Eight or more required MSSVs per SG inoperable.
SAN ONOFRE--UNIT 3 3.7-1 Amendment No. 204
MSSVs 3.7.1 Table 3.7.1-1 (page 1 of 1)
Maximum Allowable Power Level versus Inoperable MSSVs MAXIMUM MAXIMUM ALLOWABLE NUMBER OF INOPERABLE ALLOWABLE POWER LINEAR POWER MSSVs PER STEAM GENERATOR LEVEL HIGH TRIP
-RIP)
(%RTP) 2 95 95 3
56 56 4
46 46 5 to 7 MODE 3 Not applicable SAN ONOFRE--UNIT 3 3.7-3 Amendment No. 204 1
MSSVs 3.7.1 Table 3.7.1-2 (page 1 of 1)
Main Steam Safety Valves (Lift Settings)
VALVE NUMBER LIFT SETTING*
Steam Generator Steam Generator (psig)
- 1
- 2 3PSV-8401 3PSV-8410 1085 3PSV-8402 3PSV-8411 1092 3PSV-8403 3PSV-8412 1099 3PSV-8404 3PSV-8413 1106 3PSV-8405 3PSV-8414 1113 3PSV-8406 3PSV-8415 1120 3PSV-8407 3PSV-8416 1127 3PSV-8408 3PSV-8417 1134 3PSV-8409 3PSV-8418 1140 The lift setting pressure shall correspond to ambient conditions of the valve at nominal operating temperature and pressure.
Each MSSV has an as-found tolerance of +2%/-3%.
Following testing according to Technical Specification 5.5.2.10, MSSVs will be set within +/-1% of the specified lift setpoint.
SAN ONOFRE--UNIT 3 3.7-4 Amendment No. 204 1
MSSVs B 3.7.1 B 3.7 PLANT SYSTEMS B 3.7.1 Main Steam Safety Valves (MSSVs)
BASES BACKGROUND The primary purpose of the MSSVs is to provide overpressure protection for the secondary system.
The MSSVs also provide protection against overpressurizing the reactor coolant pressure boundary by providing a heat sink for the removal of energy from the Reactor Coolant System (RCS) if the preferred heat sink, provided by the Condenser and Circulating Water System, is not available.
Nine MSSVs are located on each main steam header, outside containment, upstream of the main steam isolation valves.
As described in UFSAR Section 10.3.2 (Ref.
1), the MSSVs must have sufficient capacity to limit the secondary system pressure to
- 110% of the design pressure.
This meets the requirements of Section III of the ASME Code (Ref. 2).
The ASME requirement that MSSVs lift settings should be within 1% of the specified setpoint reflects two separate objectives:
the objective to maintain lift setpoints within the bounds of the Safety Analysis and an objective to minimize the number of valves which operate to mitigate an event by staggering the valve setpoints.
This second requirement to stagger setpoints reflects good engineering design, but not safety requirements.
The objective to stagger valve setpoints constrains the less restrictive Safety Analysis requirement as a condition of Operability.
The radiological release assumptions used in the Steam Generator Tube Rupture dose assessment bound the source terms which are based on a low MSSV setpoint of 1100 psia with 15% MSSV blowdown, and considering the appropriate setpoint tolerance.
(continued)
Amendment No. 204 06/21/07 SAN ONOFRE--UNIT 3 B 3.7-1
MSSVs B 3.7.1 BASES (continued)
LCO This LCO requires all MSSVs to be OPERABLE in compliance with Reference 2, even though this is not a requirement of the DBA analysis.
This is because operation with more than one MSSV inoperable per steam generator requires limitations on allowable THERMAL POWER (to meet Reference 2 requirements) and adjustment to Reactor Protection System trip setpoints.
These limitations are according to those shown in Table 3.7.1-1, Required Action A.1, and Required Ac ion A.2. An-MSSV is-cdisidered-ino-perable if it fails to open upon demand.
The OPERABILITY of the MSSVs is defined as the ability to open in accordance with Lift Settings specified in Table 3.7.1-2, relieve Steam Generator overpressure, and reseat when pressure has been reduced.
The OPERABILITY of the MSSVs is determined by periodic surveillance testing in accordance with the inservice testing program.
The Lift Settings specified in Table 3.7.1-2 correspond to ambient conditions of the valve at nominal operating temperature and pressure.
This LCO provides assurance that the MSSVs will perform their designed safety function to mitigate the consequences of accidents that could result in a challenge to the Reactor Coolant Pressure Boundary.
APPLICABILITY In MODE 1, the accident analysis requires a minimum of five MSSVs per Steam Generator which is limiting and bounds all lower MODES.
In MODES 2 and 3, both the ASME Code and the accident analysis require only one MSSV per Steam Generator to provide overpressure protection.
In MODES 4 and 5, there are no credible transients requiring the MSSVs.
The Steam Generators are not normally used for heat removal in MODES 5 and 6, and thus cannot be overpressurized; there is no requirement for the MSSVs to be OPERABLE in these MODES.
(continued)
SAN ONOFRE--UNIT 3 B 3.7-3 Amendment No.
204 06/21/07 1
MSSVs B 3.7.1 BASES (continued)
ACTIONS The ACTIONS table is modified by a Note indicating that separate Condition entry is allowed for each MSSV.
A.1 With two to seven MSSVs per steam generator (SG) inoperable reduce power so that the available MSSV relieving capacity meets Reference 2 requirements for the applicable THERMAL POWER.
Operation with less than all nine MSSVs OPERABLE for each Steam Generator is permissible, if THERMAL POWER is limited to the relief capacity of the remaining MSSVs.
This is accomplished by restricting THERMAL POWER so that the energy transfer to the most limiting Steam Generator is not greater than the available relief capacity in that Steam Generator.
Operation at or below the allowable power will ensure the design overpressure limits will not be exceeded.
The 4-hour Completion Time for Required Action A.1 is a reasonable time period to reduce power level and is based on the low probability of an event occurring in this period that would require activation of the MSSVs.
A.2 With two to four MSSVs per SG inoperable, the ceiling on the Linear Power Level-High trip setpoint is reduced.
The reduced reactor trip allowable values are based on a detailed analysis of the Loss of Condenser Vacuum with a Concurrept Single Failure event (Ref. 3).
This anaysis considered the concerns identified in NRC Information Notice 94-60 (Ref. 6).
With five to seven MSSVs per SG inoperable, the plant must be taken to MODE 3 (per Action A.1), where the linear Power Level-High trip is not required.
(continued)
SAN ONOFRE--UNIT 3 B 3,7 Amendment No.
204 06/21/07 1
MSSVs B 3.7.1 BASES (continued)
ACTIONS A.2 (continued)
The operator should limit the maximum steady state power level to some value below this setpoint to avoid an inadvertent overpower trip.
The Completion Time of 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> for Required Action A.2 is based on the time required to perform the power reduction, operating experience in resetting all channels of a protective function, and on the low probability of the occurrence of a transient that could result in steam generator overpressure during this period.
B.1 and B.2 If the MSSVs cannot be restored to OPERABLE status in the associated Completion Time, or if one or more Steam Generators have eight or more inoperable MSSVs per SG, the unit must be placed in a MODE in which the LCO does not apply.
To achieve this status, the unit must be placed in at least MODE 3 within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />, and in MODE 4 within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.
The allowed Completion Times are reasonable, based on operating experience, to reach the required unit conditions from full power conditions in an orderly manner and without challenging unit systems.
SURVEILLANCE SR 3.7.1.1 REQUIREMENTS This SR verifies the OPERABILITY of the MSSVs by the verification of each MSSV lift setpoints in accordance with the inservice testing program.
The ASME Code,Section XI (Ref. 4), requires that safety and relief valve tests be performed in accordance with ASME OM Code, 1998 Edition through 2000 Addenda, Appendix l-Inservice Testing of Pressure Relief Devices in Light-Water Reactor Nuclear Power Plants (Ref. 5).
(continued)
SAN ONOFRE--UNIT 3 B 3.7-5 Amendment No. 204 06/21/07
MSSVs B 3.7.1 BASES (continued)
SURVEILLANCE SR 3.7.1.1 (continued)
REQUIREMENTS According to Reference 5, the following tests are required for MSSVs:
- a.
Visual examination;
- b.
Seat tightness determination;
- c.
Setpoint pressure determination (lift setting); and
- d.
Compliance with owner's seat tightness criteria.
This SR is modified by a Note that allows entry into and operation in MODE 3 prior to performing the SR.
This is to allow testing of the MSSVs at hot conditions.
The MSSVs may be either bench tested or tested in situ at hot conditions using an assist device to simulate lift pressure.
If the MSSVs are not tested at hot conditions, the lift setting pressure shall be corrected to ambient conditions of the valve at operating temperature and pressure.
REFERENCES
- 1. UFSAR, Section 10.3.2.
- 2.
ASME, Boiler and Pressure Vessel Code,Section III, Article NC-7000, Class 2 Components.
- 3.
UFSAR, Section 15.2.
- 4.
ASME, Boiler and Pressure Vessel Code,Section XI, Article IWV-3500.
- 5.
ASME OM Code, 1998 Edition through 2000 Addenda, Appendix l-Inservice Testing of Pressure Relief Devices inLight-Water Reactor Nuclear Power Plants.
- 6.
SAN ONOFRE--UNIT 3 B 3.7-6 Amendment No.
204 06/21/07 1