Surry 1 & 2 - MCR and ESGR Chilled Water Piping Replacement We have reviewed the Surry RAI response you provided via letter dated May 31, 2007 (Serial No. 07-0381), and need two additional pieces of information not provided.

1. In response to RAI #1, the licensee discussed the assumed equipment impacts to a loss of switchgear room cooling as failure of various electrical busses. However, the licensee did not identify the assumed impacts to a loss of control room cooling. The licensee stated that no alternate cooling was modeled (item D), so if control room cooling from the chillers is lost, does the PRA model simply assume core damage? If not, what is modeled as the plant impact?
2. In response to RAI #1, the licensee identified the acceptance criteria for chilled water and room coolers. However, it is not clear if the PRA model includes only the five chillers in the scope of the TS, or if the nonsafety chillers are also considered. The licensee stated that no alternate cooling was modeled (item D), which would imply that other chillers or cooling methods are not credited. A clarification as to the specific scope of the chilled water and MCR/ESGR cooling system PRA models, both for initiating events and mitigation, is requested.

Siva P. Lingam Project Manager (NRR/DORL/LPL2-1)

North Anna and Surry Nuclear Stations Location: O8-D5 Mail Stop: O8-G9 Telephone: 301-415-1564 Fax: 301-415-1222 E-mail address: spl@nrc.gov CC:

Andrew Howe Mail Envelope Properties (46656D83.481 : 13 : 35786)

Subject:

Surry 1 & 2 - MCR and ESGR Chilled Water Piping Replacement Creation Date 6/5/2007 10:04:51 AM From:

Siva Lingam Created By:

SPL@nrc.gov Recipients Action Date & Time Dom.com Transferred 6/5/2007 10:05:25 AM gary.D.Miller (gary.D.Miller@Dom.com) nrc.gov OWGWPO04.HQGWDO01 Delivered 6/5/2007 10:04:58 AM AJH1 CC (Andrew Howe)

Opened 6/5/2007 10:21:33 AM Post Office Delivered Route Dom.com

OWGWPO04.HQGWDO01 6/5/2007 10:04:58 AM nrc.gov Files Size Date & Time MESSAGE 2035 6/5/2007 10:04:51 AM Options Auto Delete:

No Expiration Date:

None Notify Recipients:

Yes Priority:

Standard ReplyRequested:

No Return Notification:

None Concealed

Subject:

No Security:

Standard To Be Delivered:

Immediate Status Tracking:

Delivered & Opened