ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT DUKE ENERGY CORPORATION CATAWBA NUCLEAR STATION Units 1 and 2 2006

i TABLE OF CONTENTS 1.0 Executive Summary.

1-1 2.0 Introduction 2-1 2.1 Site Description and Sample Locations 2-1 2.2 Scope and Requirements of the REMP 2-1 2.3 Statistical and Calculational Methodology.

2-2 2.3.1 Estimation of the Mean Value.

2-2 2.3.2 Lower Level of Detection and Minimum Detectable Activity 2-3 2.3.3 Trend Identification.

2-3 3.0 Interpretation of Results.

3-1 3.1 Airborne Radioiodine and Particulates 3-2 3.2 Drinking Water.

3-4 3.3 Surface Water.

3-6 3.4 Ground Water.

3-8 3.5 Milk.

3-9 3.6 Broadleaf Vegetation.

3-10 3.7 Food Products.

3-12 3.8 Fish.

3-13 3.9 Shoreline Sediment.

3-16 3.10 Direct Gamma Radiation.

3-18 3.11 Land Use Census 3-20 4.0 Evaluation of Dose.

4-1 4.1 Dose from Environmental Measurements.

4-1 4.2 Estimated Dose from Releases.

4-1 4.3 Comparison of Doses.

4-2 5.0 Quality Assurance 5-1 5.1 Sample Collection 5-1 5.2 Sample Analysis 5-1 5.3 Dosimetry Analysis.

5-1 5.4 Laboratory Equipment Quality Assurance.

5-1 5.4.1 Daily Quality Control 5-1 5.4.2 Calibration Verification.

5-1 5.4.3 Batch Processing 5-2 5.5 Duke Energy Intercomparison Program 5-2 5.6 Duke Energy Audits.

5-2 5.7 U.S. Nuclear Regulatory Commission Inspections 5-2 5.8 State of South Carolina Intercomparison Program 5-2 5.9 TLD Intercomparison Program.

5-2 5.9.1 Nuclear Technology Services Intercomparison Program 5-2 5.9.2 State of North Carolina Intercomparison Program 5-3 5.9.3 Internal Crosscheck (Duke Energy).

5-3 6.0 References 6-1

ii Appendices Appendix A: Environmental Sampling and Analysis Procedures A-1 I.

Change of Sampling Procedures A-2 II. Description of Analysis Procedures.

A-2 III. Change of Analysis Procedures.

A-3 IV. Sampling and Analysis Procedures A-3 A.1 Airborne Particulate and Radioiodine A-3 A.2 Drinking Water A-3 A.3 Surface Water A-4 A.4 Ground Water.

A-4 A.5 Milk A-4 A.6 Broadleaf Vegetation A-4 A.7 Food Products.

A-5 A.8 Fish A-5 A.9 Shoreline Sediment.

A-5 A.10 Direct Gamma Radiation (TLD)

A-5 A.11 Annual Land Use Census A-6 V.

Global Positioning System (GPS) Analysis.

A-6 Appendix B: Radiological Env. Monitoring Program - Summary of Results B-1 Air Particulate.

B-2 Air Radioiodine.

B-3 Drinking Water.

B-4 Surface Water.

B-5 Ground Water.

B-6 Milk.

B-7 Broadleaf Vegetation B-8 Food Products.

B-9 Fish.

B-10 Shoreline Sediment.

B-11 Direct Gamma Radiation (TLD)

B-12 Appendix C: Sampling Deviations and Unavailable Analyses C-1 C.1 Sampling Deviations C-2 C.2 Unavailable Analyses C-3 Appendix D: Analytical Deviations.

D-1 Appendix E: Radiological Environmental Monitoring Program Results E-1 LIST OF FIGURES 2.1-1 Sampling Locations Map (One Mile Radius) 2-4 2.1-2 Sampling Locations Map (Ten Mile Radius) 2-5 3.1 Concentration of Gross Beta in Air Particulate.

3-2 3.2 Concentration of Tritium in Drinking Water 3-5 3.3 Concentration of Tritium in Surface Water.

3-6 3.6 Concentration of Cs-137 in Broadleaf Vegetation 3-10 3.8-1 Concentration of Co-58 in Fish.

3-14 3.8-2 Concentration of Co-60 in Fish.

3-14 3.9-1 Concentration of Co-58 in Shoreline Sediment.

3-16 3.9-2 Concentration of Co-60 in Shoreline Sediment.

3-17 3.10 Direct Gamma Radiation (TLD) Results 3-18 3.11 2006 Land Use Census Map 3-21

iii LIST OF TABLES 2.1-A Radiological Monitoring Program Sampling Locations 2-6 2.1-B Radiological Monitoring Program Sampling Locations (TLD Sites) 2-7 2.2-A Reporting Levels for Radioactivity Concentrations in Environmental Samples 2-8 2.2-B REMP Analysis Frequency 2-8 2.2-C Maximum Values for the Lower Limits of Detection.

2-9 3.1-A Mean Concentration of Gross Beta in Air Particulate.

3-3 3.1-B Mean Concentration of Air Radioiodine (I-131).

3-3 3.2 Mean Concentrations of Radionuclides in Drinking Water.

3-5 3.3 Mean Concentrations of Radionuclides in Surface Water.

3-7 3.5 Mean Concentration of Radionuclides in Milk.

3-9 3.6 Mean Concentration of Radionuclides in Broadleaf Vegetation.

3-11 3.7 Mean Concentration of Radionuclides in Food Products 3-12 3.8 Mean Concentrations of Radionuclides in Fish.

3-15 3.9 Mean Concentrations of Radionuclides in Shoreline Sediment.

3-17 3.10 Direct Gamma Radiation (TLD) Results 3-19 3.11 Land Use Census Results.

3-20 4.1-A 2006 Environmental and Effluent Dose Comparison.

4-3 4.1-B Maximum Individual Dose for 2006 based on Environmental Measurements for Catawba Nuclear Station 4-6 5.0-A 2006 Cross-Check Results for EnRad Laboratories 5-4 5.0-B 2006 Environmental Dosimeter Cross-Check Results.

5-10 LIST OF ACRONYMS USED IN THIS TEXT (in alphabetical order)

BW BiWeekly C

Control CNS Catawba Nuclear Station DEHNR Department of Environmental Health and Natural Resources DHEC Department of Health and Environmental Control EPA Environmental Protection Agency GI-LLI Gastrointestinal - Lower Large Intestine GPS Global Positioning System LLD Lower Limit of Detection M

Monthly MDA Minimum Detectable Activity mrem Millirem NIST National Institute of Standards and Technology NRC Nuclear Regulatory Commission ODCM Offsite Dose Calculation Manual pCi/kg picocurie per kilogram pCi/l picocurie per liter pCi/m3 picocurie per cubic meter PIP Problem Investigation Process Q

Quarterly REMP Radiological Environmental Monitoring Program SA Semiannually SLCs Selected Licensee Commitments SM Semimonthly TECH SPECs Technical Specifications TLD Thermoluminescent Dosimeter

µCi/ml microcurie per milliliter UFSAR Updated Final Safety Analysis Report W

Weekly

Section 1 - Page 1 1.0 EXECUTIVE

SUMMARY

This Annual Radiological Environmental Operating Report describes the Catawba Nuclear Station Radiological Environmental Monitoring Program (REMP), and the program results for the calendar year 2006.

Included are the identification of sampling locations, descriptions of environmental sampling and analysis procedures, comparisons of present environmental radioactivity levels and pre-operational environmental data, comparisons of doses calculated from environmental measurements and effluent data, analysis of trends in environmental radiological data as potentially affected by station operations, and a summary of environmental radiological sampling results. Quality assurance practices, sampling deviations, unavailable samples, and program changes are also discussed.

Sampling activities were conducted as prescribed by Selected Licensee Commitments (SLCs). Required analyses were performed and detection capabilities were met for all collected samples as required by SLCs. Eight-hundred eighty-seven samples were analyzed comprising 1,199 test results in order to compile data for the 2006 report. Based on the annual land use census, the current number of sampling sites for Catawba Nuclear Station is sufficient.

Concentrations observed in the environment in 2006 for station related radionuclides were generally within the ranges of concentrations observed in the past. Inspection of data showed that radioactivity concentrations in surface water, drinking water, shoreline sediment, and fish are higher than the activities reported for samples collected prior to the operation of the station. Measured concentrations were not higher than expected, and all positively identified measurements were within limits as specified in SLCs.

Additionally, environmental radiological monitoring data is consistent with effluents introduced into the environment by plant operations. The total body dose estimated to the maximum exposed member of the public as calculated by environmental sampling data, excluding TLD results, was 3.82E-01 mrem for 2006. It is therefore concluded that station operations has had no significant radiological impact on the health and safety of the public or the environment.

Shoreline Sediment sampling

Section 2 - Page 1

2.0 INTRODUCTION

2.1 SITE DESCRIPTION AND SAMPLE LOCATIONS Duke Energy Corporation's Catawba Nuclear Station is a two-unit facility located on the shore of Lake Wylie in York County, South Carolina. Each of the two essentially identical units employs a pressurized water reactor nuclear steam supply system furnished by Westinghouse Electric Corporation. Each generating unit is designed to produce a net electrical output of approximately 1145 MWe. Units 1 and 2 achieved initial criticality on January 7, 1985, and May 8, 1986, respectively.

Condenser cooling is accomplished utilizing a closed system incorporating cooling towers, instead of using lake water directly. Liquid effluents are released into Lake Wylie via the station discharge canal and are not accompanied by the large additional dilution water flow associated with once-through condenser cooling. This design results in greater radionuclide concentrations in the discharge canal given comparable liquid effluent source terms.

Figures 2.1-1 and 2.1-2 are maps depicting the Thermoluminescent Dosimeter (TLD) monitoring locations and the sampling locations. The location numbers shown on these maps correspond to those listed in Tables 2.1-A and 2.1-B. Figure 2.1-1 comprises all sample locations within a one mile radius of CNS. Figure 2.1-2 comprises all sample locations within a 10 mile radius of CNS.

2.2 SCOPE AND REQUIREMENTS OF THE REMP An environmental monitoring program has been in effect at Catawba Nuclear Station since 1981, four years prior to operation of Unit 1 in 1985. The preoperational program provides data on the existing environmental radioactivity levels for the site and vicinity which may be used to determine whether increases in environmental levels are attributable to the station.

The operational program provides surveillance and backup support of detailed effluent monitoring which is necessary to evaluate the significance, if any, of the contributions to the existing environmental radioactivity levels that result from station operation.

This monitoring program is based on NRC guidance as reflected in the Selected Licensee Commitments Manual, with regard to sample media, sampling locations, sampling frequency and analytical sensitivity requirements. Indicator and control locations were established for comparison purposes to distinguish radioactivity of station origin from natural or other man-made environmental radioactivity. The environmental monitoring program also verifies projected and anticipated radionuclide concentrations in the environment and related exposures from releases of radionuclides from Catawba Nuclear Station. This program satisfies the requirements of Section IV.B.2 of Appendix I to 10CFR50 and provides surveillance of all appropriate critical exposure pathways to man and protects vital interests of

Section 2 - Page 2 the company, public and state and federal agencies concerned with the environment.

Reporting levels for activity found in environmental samples are listed in Table 2.2-A.

Table 2.2-B lists the REMP analysis and frequency schedule.

The Annual Land Use Census, required by Selected Licensee Commitments, is performed to ensure that changes in the use of areas at or beyond the site boundary are identified and that modifications to the REMP are made if required by changes in land use. This census satisfies the requirements of Section IV.B.3 of Appendix I to 10CFR50. Results are shown in Table 3.11.

Participation in an interlaboratory comparison program as required by Selected Licensee Commitments provides for independent checks on the precision and accuracy of measurements of radioactive material in REMP sample matrices. Such checks are performed as part of the quality assurance program for environmental monitoring in order to demonstrate that the results are valid for the purposes of Section IV.B.2 of Appendix I to 10CFR50. A summary of the results obtained as part of this comparison program are in Section 5 of this annual report.

2.3 STATISTICAL AND CALCULATIONAL METHODOLOGY 2.3.1 ESTIMATION OF THE MEAN VALUE There was one (1) basic statistical calculation performed on the raw data resulting from the environmental sample analysis program. The calculation involved the determination of the mean value for the indicator and the control samples for each sample medium. The mean is a widely used statistic. This value was used in the reduction of the data generated by the sampling and analysis of the various media in the REMP. The following equation was used to estimate the mean (Reference 6.8):

x

=

N N

i ix

=1 Where:

x = estimate of the mean, i = individual sample, N = total number of samples with a net activity (or concentration),

i = net activity (or concentration) for sample i.

NOTE: Net activity (or concentration)" is the activity (or concentration) determined to be present in the sample. No "Minimum Detectable Activity", "Lower Limit of Detection", "Less Than Level", or negative activities or concentrations are included in the calculation of the mean.

Section 2 - Page 3 2.3.2 LOWER LEVEL OF DETECTION AND MINIMUM DETECTABLE ACTIVITY The Lower Level of Detection (LLD), and Minimum Detectable Activity (MDA) are used throughout the REMP.

LLD - The LLD, as defined in the Selected Licensee Commitments Manual is the smallest concentration of radioactive material in a sample that will yield a net count, above the system background, that will be detected with 95% probability with only 5%

probability of falsely concluding that a blank observation represents a "real" signal.

The LLD is an a priori lower limit of detection. The actual LLD is dependent upon the standard deviation of the background counting rate, the counting efficiency, the sample size (mass or volume), the radiochemical yield and the radioactive decay of the sample between sample collection and counting. The "required" LLD's for each sample medium and selected radionuclides are given in the Selected Licensee Commitments and are listed in Table 2.2-C.

MDA - The MDA may be thought of as an "actual" LLD for a particular sample measurement remembering that the MDA is calculated using a sample background instead of a system background.

2.3.3 TREND IDENTIFICATION One of the purposes of an environmental monitoring program is to determine if there is a buildup of radionuclides in the environment due to the operation of the nuclear station. Visual inspection of tabular or graphical presentations of data (including preoperational) is used to determine if a trend exists. A decrease in a particular radionuclide's concentration in an environmental medium does not indicate that reactor operations are removing radioactivity from the environment but that reactor operations are not adding that radionuclide to the environment in quantities exceeding the preoperational level and that the normal removal processes (radioactive decay, deposition, resuspension, etc.) are influencing the concentration.

Substantial increases or decreases in the amount of a particular radionuclide's release from the nuclear plant will greatly affect the resulting environmental levels; therefore, a knowledge of the release of a radionuclide from the nuclear plant is necessary to completely interpret the trends, or lack of trends, determined from the environmental data. Factors that may affect environmental levels of radionuclides include prevailing weather conditions (periods of drought, solar cycles or heavier than normal precipitation), construction in or around either the nuclear plant or the sampling location, and addition or deletion of other sources of radioactive materials (such as the Chernobyl accident). Some of these factors may be obvious while others are sometimes unknown. Therefore, how trends are identified will include some judgment by plant personnel.

Section 2 - Page 4 Figure 2.1-1

Section 2 - Page 5 Figure 2.1-2

Section 2 - Page 6 TABLE 2.1-A CATAWBA RADIOLOGICAL MONITORING PROGRAM SAMPLING LOCATIONS Table 2.1-B Codes W

Weekly SM Semimonthly BW BiWeekly Q

Quarterly M

Monthly SA Semiannually C

Control Site Location Description*

Air Rad. &

Part.

Surface Water Drinking Water Shoreline Sediment Food Products (a)

Fish Milk Broad Leaf Veg. (b)

Ground Water 200 Site Boundary (0.63 mi NNE)

W M

201 Site Boundary (0.53 mi NE)

W M

205 Site Boundary (0.23 mi SW)

W 208 Discharge Canal (0.45 mi S)

M SA SA 210 Ebenezer Access (2.31 mi SE)

SA 211 Wylie Dam (4.06 mi ESE)

M 212 Tega Cay (3.32 mi E)

W 214 Rock Hill Water Supply (7.30 mi SSE)

M 215 C River Pointe - Hwy 49 (4.21 mi NNE)

M SA 216 C Hwy 49 Bridge (4.19 mi NNE)

SA 218 C Belmont Water Supply (13.5 mi NNE)

M 221 C Dairy (14.5 mi NW)

SM 222 Site Boundary (0.70 mi N)

M 226 Site Boundary (0.48 mi S)

M 252 Residence (0.64 mi SW)

Q 253 Irrigated Gardens (1.90 mi SSE)

M(a) 254 Residence (0.82 mi N)

Q 258 C Fairhope Road (9.84 mi W)

W M

(a) During Harvest Season (b) When Available

  • GPS data reflect approximate accuracy to within 2-5 meters. GPS field measurements were taken as close as possible to the item of interest.

Section 2 - Page 7 TABLE 2.1-B CATAWBA RADIOLOGICAL MONITORING PROGRAM SAMPLING LOCATIONS (TLD SITES)

Site Location*

Distance Sector Site Location*

Distance Sector 200 SITE BOUNDARY 0.63 miles NNE 234 HOME FEDERAL BANK 4.50 miles E

201 SITE BOUNDARY 0.53 miles NE 235 LAKE WYLIE DAM 4.07 miles ESE 203 SITE BOUNDARY 0.38 miles ESE 236 SC WILDLIFE FEDERATION OFFICE 4.25 miles SE 204 SITE BOUNDARY 0.48 miles SSW 237 TWIN LAKES ROAD AND HOMESTEAD ROAD 4.75 miles SSE 205 SITE BOUNDARY 0.23 miles SW 238 PENNINGTON ROAD AND WEST OAK ROAD 4.02 miles S

206 SITE BOUNDARY 0.67 miles WNW 239 CARTER LUMBER COMPANY 4.49 miles SSW 207 SITE BOUNDARY 0.95 miles NNW 240 PARAHAM ROAD 4.07 miles SW 212 SI TEGA CAY AIR SITE 3.32 miles E

241 CAMPBELL ROAD 4.58 miles WSW 217 C ROCK HILL AIR SITE 10.3 miles SSE 242 TRANSMISSION TOWER ON PARAHAM ROAD 4.56 miles W

222 SITE BOUNDARY 0.69 miles N

243 KINGSBERRY ROAD 4.39 miles WNW 223 SITE BOUNDARY 0.57 miles E

244 BETHEL ELEMENTARY SCHOOL 4.02 miles NW 225 SITE BOUNDARY 0.68 miles SE 245 CROWDERS CREEK BOAT LANDING 4.01 miles NNW 226 SITE BOUNDARY 0.48 miles S

246 SI CAROWINDS GUARD HOUSE 7.87 miles ENE 227 SITE BOUNDARY 0.52 miles WSW 247 C FORT MILL 7.33 miles ESE 228 SITE BOUNDARY 0.61 miles W

248 SI PIEDMONT MEDICAL CENTER 6.54 miles S

229 SITE BOUNDARY 0.84 miles NW 249 SI YORK COUNTY OPERATIONS CENTER 7.17 miles S

230 RIVER HILLS COMMUNITY CHURCH 4.37 miles N

250 SI YORK DUKE POWER OFFICE 10.4 miles WSW 231 RIVER HILLS FRONT ENTRANCE 4.21 miles NNE 251 C CLOVER 9.72 miles WNW 232 PLEASANT HILL ROAD 4.18 miles NE 255 SITE BOUNDARY 0.61 miles ENE 233 ZOAR ROAD AND THOMAS DRIVE 3.95 miles ENE 256 SITE BOUNDARY 0.58 miles SSE 258 FAIRHOPE ROAD 9.84 miles W

C = Control SI = Special Interest

  • GPS data reflect approximate accuracy to within 2-5 meters. GPS field measurements were taken as close as possible to the item of interest.

Section 2 - Page 8 TABLE 2.2-A REPORTING LEVELS FOR RADIOACTIVITY CONCENTRATIONS IN ENVIRONMENTAL SAMPLES Analysis Water (pCi/liter)

Air Particulates or Gases (pCi/m3)

Fish (pCi/kg-wet)

Milk (pCi/liter)

Food Products (pCi/kg-wet)

H-3 20,000(a),(b)

Mn-54 1,000 30,000 Fe-59 400 10,000 Co-58 1,000 30,000 Co-60 300 10,000 Zn-65 300 20,000 Zr-Nb-95 400 I-131 2

0.9 3

100 Cs-134 30 10 1,000 60 1,000 Cs-137 50 20 2,000 70 2,000 Ba-La-140 200 300 (a) If no drinking water pathway exists, a value of 30,000 pCi/liter may be used.

(b) H-3 Reporting level not applicable to surface water TABLE 2.2-B REMP ANALYSIS FREQUENCY Sample Medium Analysis Schedule Gamma Isotopic Tritium Low Level I-131 Gross Beta TLD Air Radioiodine Weekly X

Air Particulate Weekly X

X Direct Radiation Quarterly X

Surface Monthly Composite X

Water Quarterly Composite X

Drinking Monthly Composite X

(a)

X Water Quarterly Composite X

Ground Water Quarterly X

X Shoreline Sediment Semiannually X

Milk Semimonthly X

X Fish Semiannually X

Broadleaf Vegetation Monthly(b)

X Food Products Monthly(b)

X (a) Low-level I-131 analysis will be performed if the dose calculated for the consumption of drinking water is

> 1 mrem per year. An LLD of 1 pCi/liter will be required for this analysis.

(b) When Available

Section 2 - Page 9 TABLE 2.2-C MAXIMUM VALUES FOR THE LOWER LIMIT OF DETECTION Analysis Water (pCi/liter)

Air Particulates or Gases (pCi/m3)

Fish (pCi/kg-wet)

Milk (pCi/liter)

Food Products (pCi/kg-wet)

Sediment (pCi/kg-dry)

Gross Beta 4

0.01 H-3 2000 (a)

Mn-54 15 130 Fe-59 30 260 Co-58, 60 15 130 Zn-65 30 260 Zr-Nb-95 15 I-131 1(b) 0.07 1

60 Cs-134 15 0.05 130 15 60 150 Cs-137 18 0.06 150 18 80 180 Ba-La-140 15 15 (a) If no drinking water pathway exists, a value of 3000 pCi/liter may be used.

(b) If no drinking water pathway exists, the LLD of gamma isotopic analysis may be used.

Section 3 - Page 1 3.0 INTERPRETATION OF RESULTS Review of all 2006 REMP analysis results was performed to identify changes in environmental levels as a result of station operations. The following section depicts and explains the review of these results. Sample data for 2006 was compared to preoperational and historical data. Over the years of operation, analysis and collection changes have taken place that do not allow direct comparisons for some data collected from 1984 (preoperational) through 2006. Summary tables containing 2006 information required by Technical Specification Administrative Control 5.6.2 are located in Appendix B.

Evaluation for significant trends was performed for radionuclides that are listed as required within Selected Licensee Commitments 16.11-13. The radionuclides include: H-3, Mn-54, Fe-59, Co-58, Co-60, Zn-65, Zr-95, Nb-95, I-131, Cs-134, Cs-137, Ba-140 and La-140. Gross beta analysis results were trended for drinking water and gross beta trending for air particulates was initiated in 1996. Other radionuclides detected that are the result of plant operation, but not required for reporting, are trended.

A comparison of annual mean concentrations of effluent-based detected radionuclides to historical results provided trending bases. Frequency of detection and concentrations related to SLC reporting levels (Table 2.2-A) were used as criteria for trending conclusions. All 2006 maximum percentages of reporting levels were well below the 100% action level. The highest value noted during 2006 was 7.99% for tritium in drinking water collected at the Rock Hill Water Supply, Location 214.

Selected Licensee Commitment section 16.11-13 addresses actions to be taken if radionuclides other than those required are detected in samples collected. The occurrences of these radionuclides are the result of CNS liquid effluents which contained the radionuclides.

During 1979-1986, all net activity results (sample minus background), both positive and negative were included in calculation of sample mean. A change in the EnRad gamma spectroscopy system on September 1, 1987, decreased the number of measurements yielding detectable low-level activity for indicator and control location samples. It was thought that the method used by the previous system was vulnerable to false-positive results.

All 2006 sample analysis results were reviewed to detect and identify any significant trends.

Tables and graphs are used throughout this section to display data from effluent-based radionuclides identified since the system change in late 1987. All negative concentration values were replaced with zero for calculation purposes. Any zero concentrations used in tables or graphs represent activity measurements less than detectable levels.

Review of all 2006 data presented in this section supports the conclusion that there were no significant changes in environmental sample radionuclide concentrations of samples collected and analyzed from CNS site and surrounding areas that were attributable to plant operations.

Section 3 - Page 2 Concentration of Gross Beta in Air Particulate 0.00E+00 1.00E-02 2.00E-02 3.00E-02 4.00E-02 5.00E-02 6.00E-02 7.00E-02 8.00E-02 9.00E-02 1.00E-01 1984 1986 1988 1990 1992 1994 1996 1998 2000 2002 2004 2006 pCi/m 3 Indicator Location Control Location There is no reporting level for gross beta in air particulate 3.1 AIRBORNE RADIOIODINE AND PARTICULATES In 2006, 260 radioiodine and particulate samples were analyzed, 208 from four indicator locations and 52 at the control location. Particulate samples were analyzed weekly for gamma and gross beta. Radioiodine samples received a weekly gamma analysis.

Figure 3.1 shows individual sample gross beta results for the indicator location with highest annual mean and the control location samples during 2006. The two sample locations results are similar in concentration and have varied negligibly since preoperational periods.

There were no detectable gamma emitters identified for particulate filters analyzed during 2006. Table 3.1-A shows the highest indicator annual mean and control location annual mean for gross beta in air particulate.

There was no detectable I-131 in air radioiodine samples analyzed in 2006. Table 3.1-B shows the highest indicator annual mean and control location annual mean for I-131 since 1984 (preoperational period).

K-40 and Be-7 that occur naturally were routinely detected in charcoal cartridges collected during the year. Cs-137 activity was detected in one indicator cartridge in 2006. Cs-137 detection on the charcoal cartridge was determined in 1990 to be an active constituent of the charcoal. A similar study was performed in 2001 again yielding this conclusion.

Therefore, any Cs-137 activities were not used in any dose calculations in Section 4.0 of this report.

Figure 3.1

Section 3 - Page 3 Table 3.1-A Mean Concentration of Gross Beta in Air Particulate Year Indicator Location (pCi/m3)

Control Location (pCi/m3) 1984 2.25E-2 1.82E-2 1985 2.12E-2 1.53E-2 1986 3.62E-2 3.41E-2 1987 2.67E-2 2.32E-2 1988 2.29E-2 2.30E-2 1989 2.11E-2 2.13E-2 1990 2.39E-2 2.72E-2 1991 2.19E-2 2.51E-2 1992 1.90E-2 2.01E-2 1993 1.87E-2 1.94E-2 1994 2.03E-2 2.03E-2 1995 4.88E-2 3.23E-2 1996 3.49E-2 2.60E-2 1997 2.83E-2 2.28E-2 1998 2.69E-2 2.12E-2 1999 2.53E-2 2.04E-2 2000 2.28E-2 1.86E-2 2001 1.76E-2 1.78E-2 2002 1.60E-2 1.57E-2 2003 1.54E-2 1.42E-2 2004 1.65E-2 1.49E-2 2005 1.66E-2 1.68E-2 Average (1996 - 2005) 2.20E-2 1.88E-2 2006 1.74E-02 1.74E-02 Table 3.1-B Mean Concentration of Air Radioiodine (I-131)

Year Indicator Location (pCi/m3)

Control Location (pCi/m3) 1984 1.30E-3 1.46E-2 1985 4.75E-3 2.38E-2 1986 1.43E-2 1.02E-2 1987 1.38E-2 0.00E0 1988 0.00E0 0.00E0 1989 0.00E0 0.00E0 1990 0.00E0 0.00E0 1991 0.00E0 0.00E0 1992 0.00E0 0.00E0 1993 0.00E0 0.00E0 1994 0.00E0 0.00E0 1995 0.00E0 0.00E0 1996 0.00E0 0.00E0 1997 0.00E0 0.00E0 1998 0.00E0 0.00E0 1999 0.00E0 0.00E0 2000 0.00E0 0.00E0 2001 0.00E0 0.00E0 2002 0.00E0 0.00E0 2003 0.00E0 0.00E0 2004 0.00E0 0.00E0 2005 0.00E0 0.00E0 2006 0.00E0 0.00E0 0.00E0 = no detectable measurements

Section 3 - Page 4 3.2 DRINKING WATER Gross beta and gamma spectroscopy were performed on 26 drinking water samples. The samples were composited to create 8 quarterly samples that were analyzed for tritium. One indicator location was sampled, along with one control location.

No gamma emitting radionuclides were identified in 2006 drinking water samples. There have been no gamma emitting radionuclides identified in drinking water samples since 1988.

Table 3.2 shows highest annual mean gross beta concentrations for the indicator location and control location since preoperation. The indicator location (downstream of the plant effluent release point) average concentration was 2.30 pCi/l in 2006 and the control location concentration was 2.17 pCi/l. The 2005 indicator mean was 2.05 pCi/l. The table shows that current gross beta levels are not statistically different from preoperational concentrations.

Tritium was detected at low levels in the four indicator samples and the four control samples during 2006. The mean indicator tritium concentration for 2006 was 1598 pCi/l, 7.99% of reporting level. The mean control tritium concentration for 2005 was 769 pCi/l, 3.85% of reporting level. Figure 3.2 and Table 3.2 display the highest indicator and control location annual mean concentrations for tritium since 1984.

Tritium in drinking water control and indicator samples was higher in 2006 because of increased release volumes due to plant operations (See PIP C-06-08761) and releases from the McGuire Nuclear Station located approximately 40 miles upstream of Catawba on the Catawba River.

The dose for consumption of water was less than one mrem per year, historically and for 2006; therefore low-level iodine analysis is not required.

Section 3 - Page 5 Figure 3.2 Concentration of Tritium in Drinking Water 0

500 1000 1500 2000 2500 3000 3500 4000 4500 5000 1984 1986 1988 1990 1992 1994 1996 1998 2000 2002 2004 2006 pCi/liter Indicator Location Control Location 10% Reporting Level Table 3.2 Mean Concentration of Radionuclides in Drinking Water Gross Beta (pCi/l)

Tritium (pCi/l)

YEAR Indicator Location Control Location Indicator Location Control Location 1984 4.72 1.83 3.10E-2 3.10E-2 1985 2.70 2.24 4.13E2 4.00E2 1986 3.11 2.26 7.23E2 7.33E2 1987 3.10 2.40 7.80E2 4.80E2 1988 3.60 2.60 6.64E2 0.00E0 1989 3.60 2.90 8.91E2 5.72E2 1990 4.50 3.20 7.03E2 0.00E0 1991 3.70 2.20 7.04E2 0.00E0 1992 3.20 2.40 7.65E2 5.38E2 1993 3.50 2.50 7.06E2 0.00E0 1994 3.30 2.70 0.00E0 0.00E0 1995 4.80 4.50 4.28E2 2.21E2 1996 3.08 3.14 3.71E2 3.27E2 1997 3.74 3.15 3.54E2 2.28E2 1998 2.51 2.44 5.07E2 1.83E2 1999 3.55 2.48 6.71E2 2.70E2 2000 3.04 2.27 5.87E2 3.26E2 2001 3.49 2.30 8.66E2 4.50E2 2002 3.44 2.36 1.22E3 4.11E2 2003 2.27 2.02 6.36E2 2.88E2 2004 1.88 1.69 5.47E2 2.54E2 2005 2.05 1.84 7.69E2 4.50E2 2006 2.30 2.17 1.59E3 7.70E2 0.00E0 = no detectable measurements 1984 - 1986 mean based on all net activity

Section 3 - Page 6 Concentration of Tritium in Surface Water 0

5000 10000 15000 20000 25000 30000 1984 1986 1988 1990 1992 1994 1996 1998 2000 2002 2004 2006 pCi/liter Indicator Location Control Location 3.3 SURFACE WATER A total of 39 monthly surface water samples was analyzed for gamma emitting radionuclides.

The samples were composited to create 12 quarterly samples for tritium analysis. Two indicator locations and one control location were sampled. One indicator location (208) is located near the liquid effluent discharge point.

Tritium was the only radionuclide identified in surface water samples collected during 2006.

All indicator location samples contained tritium with an average concentration of 8998 pCi/l.

Indicator Location 208 (Discharge Canal) showed a range of activities from 15400 to 18000 pCi/l which had the highest mean concentration of 16700 pCi/l. Tritium was detected in all four control samples during 2006 with an average concentration of 583 pCi/l.

Figure 3.3 displays the indicator and control annual means for tritium since 1984. Table 3.3 lists indicator annual means.

Tritium in surface water was higher than usual during 2006 because of increased release volumes due to plant operations (See PIP C-06-08761) and releases from the McGuire Nuclear Station located approximately 40 miles upstream of Catawba on the Catawba River.

Figure 3.3 There is no reporting level for tritium in surface water, however, if no drinking water pathway exists, a value of 30,000 pCi/l may be used. A drinking water pathway exists for Catawba Nuclear Station, so this limit does not apply for surface water. See section 3.2 for drinking water results.

Section 3 - Page 7 Table 3.3 Mean Concentrations of Radionuclides in Surface Water (pCi/l)

YEAR Co-58 Co-60 Nb-95 Cs-137 H-3 Indicator H-3 Control 1984 4.59E-1 5.71E-1 6.48E-1 9.08E-1 3.35E2 3.18E2 1985 3.46E0 4.83E-2 2.70E0 8.19E-1 1.19E3 5.05E2 1986 3.10E-1

-4.12E-2 2.05E0 4.85E-1 2.34E3 5.05E2 1987 0.00E0 3.10E0 4.30E0 9.90E0 4.17E3 6.20E2 1988 9.20E0 0.00E0 0.00E0 0.00E0 6.03E3 6.07E2 1989 0.00E0 0.00E0 0.00E0 0.00E0 5.27E3 0.00E0 1990 6.50E0 0.00E0 0.00E0 0.00E0 3.98E3 7.73E2 1991 0.00E0 0.00E0 0.00E0 0.00E0 4.87E3 0.00E0 1992 0.00E0 0.00E0 0.00E0 0.00E0 6.91E3 6.64E2 1993 4.70E0 1.80E0 0.00E0 0.00E0 5.98E3 0.00E0 1994 0.00E0 0.00E0 0.00E0 0.00E0 8.42E3 0.00E0 1995 0.00E0 0.00E0 0.00E0 0.00E0 5.13E3 2.89E2 1996 0.00E0 0.00E0 0.00E0 0.00E0 7.36E3 2.61E2 1997 0.00E0 0.00E0 0.00E0 0.00E0 7.77E3 2.20E2 1998 0.00E0 0.00E0 0.00E0 0.00E0 6.61E3 0.00E0 1999 0.00E0 0.00E0 0.00E0 0.00E0 8.13E3 2.41E2 2000 0.00E0 0.00E0 0.00E0 0.00E0 7.19E3 2.56E2 2001 0.00E0 0.00E0 0.00E0 0.00E0 7.13E3 3.28E2 2002 0.00E0 0.00E0 0.00E0 0.00E0 1.00E4 3.80E2 2003 0.00E0 0.00E0 0.00E0 0.00E0 1.31E4 2.37E2 2004 0.00E0 0.00E0 0.00E0 0.00E0 9.43E3 2.60E2 2005 0.00E0 0.00E0 0.00E0 0.00E0 1.40E4 3.78E2 2006 0.00E0 0.00E0 0.00E0 0.00E0 1.67E4 5.83E2 0.00E0 = no detectable measurements 1984 - 1986 mean based on all net activity

Section 3 - Page 8 3.4 GROUND WATER A total of eight ground water samples was collected and analyzed for gamma emitters. There are two indicator locations and no control locations. Naturally occurring K-40 was the only radionuclide identified during 2006.

There have been no radionuclides identified in ground water samples since 1988. Only naturally occurring K-40 and Be-7 were noted.

Section 3 - Page 9 3.5 MILK A total of 26 milk samples was analyzed by gamma spectroscopy and low level iodine during 2006. There was one control location sampled. No indicator dairies were identified by the 2006 land use census.

There were no gamma emitting radionuclides identified in milk during 2006. Airborne Cs-137 has not been released from the plant since 1992.

Cs-137 was last detected in an indicator sample during 1996. The occurrence of Cs-137 in milk samples has been noted several times since 1984. During 1995 there was also one sample analyzed in which Cs-137 was identified with a concentration of 8.6 pCi/l. Cs-137 attributable to past nuclear weapons testing is known to exist in many environmental media at low, highly variable levels.

Table 3.5 lists highest indicator location annual mean and control location annual mean for Cs-137 since the preoperational period. Concentrations are similar for the two sample types. Cs-137 is the only radionuclide, other than K-40 and Be-7, reported in milk samples since 1988.

Table 3.5 Mean Concentration of Radionuclides in Milk YEAR Cs-137 Indicator (pCi/l)

Cs-137 Control (pCi/l) 1984 2.95E0 2.98E0 1985 2.11E0 2.12E0 1986 3.76E0 4.54E0 1987 5.00E0 5.50E0 1988 3.20E0 3.80E0 1989 0.00E0 0.00E0 1990 8.00E0 6.70E0 1991 0.00E0 0.00E0 1992 3.40E0 5.00E0 1993 5.00E0 0.00E0 1994 2.80E0 0.00E0 1995 8.60E0 0.00E0 1996 6.05E0 0.00E0 1997 0.00E0 0.00E0 1998 0.00E0 0.00E0 1999 0.00E0 0.00E0 2000 0.00E0 0.00E0 2001 0.00E0 0.00E0 2002 0.00E0 0.00E0 2003 0.00E0 0.00E0 2004 NO INDICATOR LOCATION 0.00E0 2005 NO INDICATOR LOCATION 0.00E0 2006 NO INDICATOR LOCATION 0.00E0 0.00E0 = no detectable measurements 1984 - 1986 mean based on all net activity

Section 3 - Page 10 Concentration of Cs-137 in Broadleaf Vegetation 0

200 400 600 800 1000 1200 1984 1986 1988 1990 1992 1994 1996 1998 2000 2002 2004 2006 pCi/kg Indicator Location Control Location 50% Reporting Level 3.6 BROADLEAF VEGETATION Gamma spectroscopy was performed on 60 broadleaf vegetation samples during 2006.

Four indicator locations and one control location were sampled.

Nine of the forty-eight samples collected at indicator locations contained detectable Cs-137 activity. Cs-137 was detected in nine of the twelve samples collected at Location 201. The highest concentration detected at Location 201 was 125 pCi/kg which is 6.25%

of the reporting level. Cs-137 was not detected in any of the twelve control location samples.

Figure 3.6 shows indicator and control annual means for Cs-137 in vegetation since 1984. Table 3.6 lists indicator and annual means. Values shown from 1984 to 2006 show a stable trend for Cs-137 in vegetation.

No airborne Cs-137 has been released from the plant since 1992. Cs-137 attributable to past nuclear weapons testing is known to exist in many environmental media at low and highly variable levels.

K-40 and Be-7 were observed in broadleaf vegetation samples.

Figure 3.6

Section 3 - Page 11 Table 3.6 Mean Concentration of Radionuclides in Broadleaf Vegetation YEAR Cs-137 Indicator (pCi/kg)

Cs-137 Control (pCi/kg) 1984 3.76E1 1.30E1 1985 5.48E1 4.16E1 1986 7.42E1 2.22E1 1987 6.10E1 5.10E1 1988 9.10E1 7.40E1 1989 1.00E2 4.80E1 1990 7.70E1 5.80E1 1991 1.98E2 8.60E1 1992 9.70E1 0.00E0 1993 1.13E2 3.20E1 1994 7.00E1 0.00E0 1995 3.60E1 0.00E0 1996 2.23E2 6.22E1 1997 7.57E1 0.00E0 1998 6.53E1 0.00E0 1999 1.08E2 0.00E0 2000 1.04E2 0.00E0 2001 3.76E1 0.00E0 2002 7.02E1 0.00E0 2003 4.96E1 2.40E1 2004 5.45E1 0.00E0 2005 5.48E1 0.00E0 2006 5.79E1 0.00E0 0.00E0 = no detectable measurements 1984 - 1986 mean based on all net activity

Section 3 - Page 12 3.7 FOOD PRODUCTS Collection of food product samples (crops) from an irrigated garden began in 1989. The garden is located on Lake Wylie downstream from CNS, Location 253. During the 2006 growing season, four samples were collected and analyzed for gamma radionuclides.

There is no control location for this media type.

Table 3.7 shows Cs-137 indicator location highest annual mean concentrations since 1989.

Table 3.7 Mean Concentration of Radionuclides in Food Products YEAR Cs-137 Indicator (pCi/kg) 1989 0.00E0 1990 0.00E0 1991 0.00E0 1992 0.00E0 1993 2.50E1 1994 0.00E0 1995 0.00E0 1996 0.00E0 1997 0.00E0 1998 0.00E0 1999 0.00E0 2000 0.00E0 2001 0.00E0 2002 0.00E0 2003 0.00E0 2004 0.00E0 2005 0.00E0 2006 0.00E0 0.00E0 = no detectable measurements

Section 3 - Page 13 3.8 FISH Gamma spectroscopy was performed on 12 fish samples collected during 2006. One downstream indicator location and one control location were sampled.

Co-58, Co-60, and Cs-137 are normally the predominant radionuclides identified in fish samples. Cs-137 was detected in one indicator sample in 2006 at a concentration of 14.4 pCi/kg, which is 0.72% of the reporting level. Cs-137 was not detected in any control location samples.

Figures 3.8-1 and 3.8-2 are graphs displaying annual mean concentrations for Co-58 and Co-60. Table 3.8 depicts the highest indicator location annual mean for radionuclides detected. In addition, radionuclides identified in fish samples since 1988 have been included in the table. Overall, radionuclides have not shown a

significant trend or accumulation.

K-40 was observed in fish samples collected during 2006.

Section 3 - Page 14 Figure 3.8-1 Figure 3.8-2 Concentration of Co-58 in Fish 0

200 400 600 800 1000 1200 1400 1600 1800 2000 1984 1986 1988 1990 1992 1994 1996 1998 2000 2002 2004 2006 pCi/kg Indicator Location Control Location 5 % Reporting Level Concentration of Co-60 in Fish 0

100 200 300 400 500 600 700 1984 1986 1988 1990 1992 1994 1996 1998 2000 2002 2004 2006 pCi/kg Indicator Location Control Location 5% Reporting Level

Section 3 - Page 15 Table 3.8 Mean Concentrations of Radionuclides in Fish (pCi/kg)

Year Mn-54 Co-58 Co-60 Cs-134 Cs-137 Nb-95 Fe-59 Sb-122 Sb-125 1984 3.07E0 3.00E0 6.11E-1

-5.32E0 1.83E0 0.00E0 0.00E0 0.00E0 0.00E0 1985 7.68E-1 3.40E1 9.11E0 3.22E0 1.28E1 5.07E0 0.00E0 0.00E0 0.00E0 1986 2.01E1 1.86E2 4.01E1 3.51E1 9.29E1 0.00E0 7.30E0 0.00E0 0.00E0 1987 7.24E0 7.57E1 4.81E1 3.83E0 4.27E1 5.40E0 0.00E0 0.00E0 0.00E0 1988 2.85E1 1.40E2 9.70E1 1.67E1 8.24E1 0.00E0 0.00E0 0.00E0 0.00E0 1989 8.28E0 1.33E2 3.83E1 1.47E1 4.37E1 8.58E-1 0.00E0 0.00E0 0.00E0 1990 2.51E1 1.75E2 7.77E1 1.32E1 4.66E1 3.33E0 0.00E0 7.00E0 9.25E0 1991 3.15E1 1.46E2 1.29E2 1.03E1 4.60E1 7.90E-1 2.30E0 0.00E0 7.45E0 1992 1.34E1 9.02E1 6.20E1 1.27E1 4.61E1 0.00E0 0.00E0 0.00E0 0.00E0 1993 2.14E1 3.58E2 1.21E2 2.73E0 2.56E1 0.00E0 0.00E0 0.00E0 0.00E0 1994 1.91E0 4.75E1 1.81E1 0.00E0 1.75E1 0.00E0 0.00E0 0.00E0 1.45E1 1995 5.65E1 8.90E2 2.66E2 0.00E0 6.77E1 1.38E1 0.00E0 0.00E0 0.00E0 1996 0.00E0 5.95E1 6.68E1 0.00E0 3.02E1 0.00E0 0.00E0 0.00E0 0.00E0 1997 0.00E0 4.93E1 9.88E0 0.00E0 2.74E1 0.00E0 0.00E0 0.00E0 0.00E0 1998 0.00E0 6.44E1 2.86E1 0.00E0 1.58E1 0.00E0 0.00E0 0.00E0 0.00E0 1999 0.00E0 3.12E1 2.71E1 0.00E0 1.87E1 0.00E0 0.00E0 0.00E0 0.00E0 2000 0.00E0 2.13E2 2.69E2 0.00E0 1.52E1 0.00E0 0.00E0 0.00E0 0.00E0 2001 0.00E0 4.66E1 0.00E0 0.00E0 2.08E1 0.00E0 0.00E0 0.00E0 0.00E0 2002 0.00E0 5.23E1 7.00E1 0.00E0 1.73E1 0.00E0 0.00E0 0.00E0 0.00E0 2003 0.00E0 1.43E2 2.61E1 0.00E0 1.19E1 0.00E0 0.00E0 0.00E0 0.00E0 2004 4.92E1 1.81E1 0.00E0 0.00E0 0.00E0 0.00E0 0.00E0 0.00E0 0.00E0 2005 0.00E0 0.00E0 0.00E0 0.00E0 0.00E0 0.00E0 0.00E0 0.00E0 0.00E0 2006 0.00E0 0.00E0 0.00E0 0.00E0 1.44E1 0.00E0 0.00E0 0.00E0 0.00E0 0.00E0 = no detectable measurements

Section 3 - Page 16 3.9 SHORELINE SEDIMENT During 2006, a total of 6 shoreline sediment samples was analyzed, four from two indicator locations and two from the control location.

Co-58 and Co-60 were identified in one sample collected from indicator location 208-1S, which is closest to the plants liquid effluent release point. Naturally occurring K-40 was identified in many of the indicator and control locations. Activity released in plant effluents has decreased since 1996 and as a result decreased activity has been measured in the environment.

The shoreline sediment location with the highest annual mean for all detectable radionuclides was location 208-1S. Co-58 was identified at location 208-1S with an annual mean concentration of 54.0 pCi/kg. Co-60 was identified with an annual mean concentration of 111 pCi/kg. Naturally occurring K-40 and Be-7 were also identified in samples from this location.

Table 3.9 lists highest indicator location annual mean since 1984. Included in the table are radionuclides that have been identified in shoreline sediment samples since 1988.

Figure 3.9-1 graphically depicts Co-58 annual mean concentrations. Figure 3.9-2 depicts Co-60 annual mean concentrations.

Figure 3.9-1 There is no reporting level for Co-58 in Shoreline Sediment Concentration of Co-58 in Shoreline Sediment 0

200 400 600 800 1000 1200 1400 1600 1800 2000 1984 1986 1988 1990 1992 1994 1996 1998 2000 2002 2004 2006 pCi/kg Indicator Location Control Location

Section 3 - Page 17 Figure 3.9-2 There is no reporting level for Co-60 in Shoreline Sediment Table 3.9 Mean Concentrations of Radionuclides in Shoreline Sediment (pCi/kg)

Year Mn-54 Co-58 Co-60 Nb-95 Zr-95 Cs-134 Cs-137 Co-57 Sb-125 1984 1.03E0 4.40E0

-2.34E0 0.00E0 0.00E0 3.19E1 1.07E2 0.00E0 0.00E0 1985

-3.12E0 1.16E2 5.18E0 0.00E0 0.00E0 2.11E2 2.97E2 0.00E0 0.00E0 1986 1.09E2 3.79E2 2.05E2 0.00E0 3.96E1 6.50E1 1.61E2 0.00E0 0.00E0 1987 8.83E1 4.08E2 1.61E2 4.22E1 0.00E0 6.08E1 1.26E2 0.00E0 0.00E0 1988 1.07E2 3.29E2 2.63E2 2.28E1 7.54E0 2.59E1 1.07E2 7.65E-1 3.68E0 1989 4.58E1 1.94E2 1.21E2 5.02E0 0.00E0 1.65E1 5.77E1 0.00E0 1.57E1 1990 5.39E1 2.08E2 1.77E2 0.00E0 0.00E0 1.66E1 8.18E1 0.00E0 7.15E0 1991 8.50E1 3.70E2 4.19E2 5.30E0 0.00E0 1.82E1 8.33E1 1.20E0 1.50E1 1992 1.17E2 1.13E3 5.80E2 3.50E0 0.00E0 1.69E1 1.07E2 3.00E0 2.70E1 1993 1.33E2 1.07E3 1.04E3 0.00E0 0.00E0 2.80E1 1.26E2 2.47E1 2.16E2 1994 4.93E1 7.98E2 5.73E2 0.00E0 0.00E0 5.67E0 1.07E2 4.38E0 4.60E1 1995 1.02E2 1.33E3 8.65E2 1.13E2 0.00E0 0.00E0 8.50E1 3.69E1 1.49E2 1996 8.73E1 3.39E2 5.81E2 0.00E0 0.00E0 0.00E0 8.30E1 0.00E0 1.96E2 1997 6.96E1 5.90E2 7.64E2 0.00E0 0.00E0 0.00E0 1.43E2 0.00E0 1.76E2 1998 3.07E1 1.88E2 2.30E2 0.00E0 0.00E0 0.00E0 7.11E1 0.00E0 0.00E0 1999 7.28E1 2.29E2 4.39E2 0.00E0 0.00E0 0.00E0 9.42E1 0.00E0 1.40E2 2000 0.00E0 3.90E1 1.03E2 0.00E0 0.00E0 0.00E0 4.96E1 0.00E0 0.00E0 2001 3.86E1 8.27E1 3.29E2 0.00E0 0.00E0 0.00E0 5.58E1 0.00E0 0.00E0 2002 3.51E1 2.41E2 2.22E2 0.00E0 0.00E0 0.00E0 8.83E1 0.00E0 0.00E0 2003 2.17E1 8.75E1 1.08E2 0.00E0 0.00E0 0.00E0 2.69E1 0.00E0 0.00E0 2004 6.60E1 2.67E2 3.83E2 0.00E0 0.00E0 0.00E0 3.79E1 0.00E0 0.00E0 2005 0.00E0 1.61E2 1.41E2 0.00E0 0.00E0 0.00E0 0.00E0 0.00E0 0.00E0 2006 0.00E0 5.40E1 1.11E2 0.00E0 0.00E0 0.00E0 0.00E0 0.00E0 0.00E0 0.00E0 = no detectable measurements 1984 - 1986 mean based on all net activity Negative values are calculated as zeroes Concentration of Co-60 in Shoreline Sediment 0

200 400 600 800 1000 1200 1400 1600 1800 2000 1984 1986 1988 1990 1992 1994 1996 1998 2000 2002 2004 2006 pCi/kg Indicator Location Control Location

Section 3 - Page 18 3.10 DIRECT GAMMA RADIATION In 2006, 158 TLDs were analyzed, 147 at indicator locations and 11 at control locations.

TLDs are collected and analyzed quarterly.

The highest annual mean exposure for an indicator location was 105.6 milliroentgen.

The annual mean exposure for the control locations was 57.2 milliroentgen.

Figure 3.10 and Table 3.10 show TLD inner ring (site boundary), outer ring (4-5 miles),

and control location annual averages in milliroentgen per year. Preoperational data and rolling ten year operational data averages are also given. As shown in the graph, inner ring, outer ring, and control data averages historically compare closely. Inner and outer ring averages comprise a number of data points with control averages representing only three locations.

The calculated total body dose (from gaseous effluents) for 2006 was 5.95E-1 mrem, which is 0.77% of the average inner ring TLD values. Therefore, it can be concluded that discharges from the plant had very little impact upon the measured TLD values.

Figure 3.10 There is no reporting level for Direct Radiation (TLD)

Direct Gamma Radiation (TLD) Results 0

50 100 150 200 250 1984 1986 1988 1990 1992 1994 1996 1998 2000 2002 2004 2006 mR/year Inner Ring Outer Ring Control

Section 3 - Page 19 Table 3.10 Direct Gamma Radiation (TLD) Results Year Inner Ring Average (mR/yr)

Outer Ring Average (mR/yr)

Control Average (mR/yr) 1984*

87.5 82.6 79.3 1985 116.9 108.7 108.9 1986 104.3 98.5 94.4 1987 97.0 87.4 84.7 1988 74.6 70.3 67.1 1989 67.1 60.8 60.0 1990 52.0 44.5 39.1 1991 62.0 54.1 46.7 1992 80.4 72.5 64.5 1993 70.3 60.9 53.6 1994 76.3 69.3 63.9 1995 99.6 89.7 80.8 1996 84.3 73.9 63.6 1997 82.4 71.9 57.4 1998 85.3 74.2 64.6 1999 80.0 68.1 57.8 2000 75.0 63.0 52.4 2001 81.0 70.5 55.2 2002 78.8 69.5 55.2 2003 81.7 72.6 56.0 2004 78.6 73.8 55.6 2005 79.8 75.2 57.7 Average (1996 - 2005) 80.7 71.3 57.6 2006 76.9 73.6 57.2

  • Preoperational Data

Section 3 - Page 20 3.11 LAND USE CENSUS The 2006 Annual Land Use Census was conducted July 17 and July 18, 2006 as required by SLC 16.11-14. Table 3.11 summarizes census results. A map indicating identified locations is shown in Figure 3.11.

During the 2006 census, no new or closer irrigated gardens were identified. The nearest residence is located in the NE sector at 0.56 miles. No environmental program changes were required as a result of the 2006 land use census.

Table 3.11 Catawba 2006 Land Use Census Results Sector Distance (Miles)

Sector Distance (Miles)

N Nearest Residence Nearest Garden Nearest Milk Animal 0.63 1.55 S

Nearest Residence Nearest Garden Nearest Milk Animal 0.63 0.80 NNE Nearest Residence Nearest Garden Nearest Milk Animal 0.66 2.53 SSW Nearest Residence Nearest Garden Nearest Milk Animal 0.81 1.67 NE Nearest Residence Nearest Garden Nearest Milk Animal 0.56 2.87 SW Nearest Residence Nearest Garden (irrigated)

Nearest Milk Animal 0.66 0.66 ENE Nearest Residence Nearest Garden (irrigated)

Nearest Milk Animal 0.61 0.61 WSW Nearest Residence Nearest Garden Nearest Milk Animal 0.64 2.04 E

Nearest Residence Nearest Garden Nearest Milk Animal 0.65 3.51 W

Nearest Residence Nearest Garden Nearest Milk Animal 0.81 0.96 ESE Nearest Residence Nearest Garden Nearest Milk Animal 0.84 1.23 WNW Nearest Residence Nearest Garden Nearest Milk Animal 1.10 1.19 SE Nearest Residence Nearest Garden (irrigated)

Nearest Milk Animal 0.97 2.55 NW Nearest Residence Nearest Garden Nearest Milk Animal 1.39 1.54 SSE Nearest Residence Nearest Garden Nearest Milk Animal 0.74 1.01 NNW Nearest Residence Nearest Garden Nearest Milk Animal 1.06 2.21

- indicates no occurrences within the 5 mile radius

Section 3 - Page 21 Figure 3.11

Section 4 - Page 1 4.0 EVALUATION OF DOSE 4.1 DOSE FROM ENVIRONMENTAL MEASUREMENTS Annual doses to maximum exposed individuals were estimated based on measured concentrations of radionuclides in 2006 CNS REMP samples. The primary purpose of estimating doses based on sample results is to allow comparison to effluent program dose estimates.

Doses based on sample results were calculated using the methodology and data presented in NRC Regulatory Guide 1.109. Measured radionuclide concentrations, averaged over the entire year for a specific radionuclide, indicator location and sample type, were used to calculate REMP-based doses. Where applicable, average background concentration at the corresponding control location was subtracted.

Regulatory Guide 1.109 consumption rates for the maximum exposed individual were used in the calculations. When the guide listed NO DATA as the dose factor for a given radionuclide and organ, a dose factor of zero was assumed.

Maximum dose estimates (Highest Annual Mean Concentration) based on drinking water, broadleaf vegetation, fish, and shoreline sediment sample results are reported in Table 4.1-A. The individual critical population and pathway dose calculations are reported in Table 4.1-B.

REMP-based dose estimates are not reported for airborne radioiodine, airborne particulate, milk, or ground water sample types because no radionuclides other than naturally occurring K-40 and Be-7 were detected in the samples. Dose estimates are not reported for surface water because sampled surface water is not considered to be a potable drinking water source although surface water tritium concentrations are used in calculating doses from fish. Exposure estimates based upon REMP TLD results are discussed in Section 3.10.

The maximum environmental organ dose estimate for any single sample type (other than direct radiation from gaseous effluents) collected during 2006 was 5.95E-1 mrem to the maximum exposed child total body from consuming broadleaf vegetation.

4.2 ESTIMATED DOSE FROM RELEASES Throughout the year, dose estimates were calculated based on actual 2006 liquid and gaseous effluent release data. Effluent-based dose estimates were calculated using the RETDAS computer program which employs methodology and data presented in NRC Regulatory Guide 1.109. These doses are shown in Table 4.1-A along with the corresponding REMP-based dose estimates. Summaries of RETDAS dose

Section 4 - Page 2 calculations are reported in the Annual Radioactive Effluent Release Report (reference 6.6).

The effluent-based liquid release doses are summations of the dose contributions from the drinking water, fish, and shoreline pathways. The effluent-based gaseous release doses report noble gas exposure separately from iodine, particulate, and tritium exposure. For noble gas exposure there is no critical age group; as the maximum exposed individuals are assumed to receive the same doses, regardless of their age group. For iodine, particulate, and tritium exposure the effluent-based gaseous release doses are summations of the dose contributors from ground/plane, inhalation, milk and vegetation pathways.

4.3 COMPARISON OF DOSES The environmental and effluent dose estimates given in Table 4.1-A agree reasonably well. The similarity of the doses indicate that the radioactivity levels in the environment do not differ significantly from those expected based on effluent measurements and modeling of the environmental exposure pathways. This indicates that effluent program dose estimates are both valid and reasonably conservative.

There are some differences in how effluent and environmental doses are calculated that affect the comparison. Doses calculated from environmental data are conservative because they are based on a mean that includes only samples with a net positive activity versus a mean that includes all sample results (i.e. zero results are not included in the mean). Also, airborne tritium is not measured in environmental samples but is used to calculate effluent doses.

In calculations based on liquid release pathways, fish, drinking water, and shoreline sediment were the predominant dose pathways based on environmental and effluent data. The maximum total organ dose based on 2006 environmental sample results was 1.37E-1 mrem to the child liver. The maximum total organ dose of 1.71E-1 mrem for liquid effluent-based estimates was to the adult GI-LLI.

In calculations based on gaseous release pathways, vegetation was the predominant dose pathway for effluent samples. The maximum total organ dose for gaseous effluent estimates was 5.95E-1 mrem to the childs liver, total body, thyroid, kidney, lung, and GI-LLI. Vegetation was the predominant dose pathway for environmental samples. The maximum total organ dose for gaseous environmental estimates was 4.92E-1 mrem to the child bone.

Noble gas samples are not collected as part of the REMP, preventing an analogous comparison of effluent-based noble gas exposure estimates.

The doses calculated do not exceed the 40CFR190 dose commitment limits for members of the public. Doses to members of the public attributable to the operation of CNS are being maintained well within regulatory limits.

TABLE 4.1-A Page 1 of 3 CATAWBA NUCLEAR STATION 2006 ENVIRONMENTAL AND EFFLUENT DOSE COMPARISON LIQUID RELEASE PATHWAY Organ Environmental or Effluent Data Critical Age (1)

Critical Pathway (2)

Location Maximum Dose (3)

(mrem)

Skin Environmental Teen Shoreline Sediment 208 (0.45 mi S) 1.43E-03 Skin Effluent Teen Shoreline Sediment 0.5 mi S 9.41E-03 Bone Environmental Child Fish 208 (0.45 mi S) 3.25E-02 Bone Effluent Teen Fish 0.5 mi S 1.92E-02 Liver Environmental Child Drinking Water 214 (7.30 mi SSE) 1.37E-01 Liver Effluent Child Drinking Water 0.5 mi S 1.13E-01 T. Body Environmental Adult Drinking Water 214 (7.30 mi SSE) 1.17E-01 T. Body Effluent Child Drinking Water 0.5 mi S 1.02E-01 Thyroid Environmental Child Drinking Water 214 (7.30 mi SSE) 1.06E-01 Thyroid Effluent Child Drinking Water 0.5 mi S 9.82E-02 Kidney Environmental Child Drinking Water 214 (7.30 mi SSE) 1.16E-01 Kidney Effluent Child Drinking Water 0.5 mi S 1.03E-01 Lung Environmental Child Drinking Water 214 (7.30 mi SSE) 1.10E-01 Lung Effluent Child Drinking Water 0.5 mi S 9.97E-02 GI-LLI Environmental Child Drinking Water 214 (7.30 mi SSE) 1.06E-01 GI-LLI Effluent Adult Fish 0.5 mi S 1.71E-01 (1) Critical Age is the highest total dose (all pathways) to an age group.

(2) Critial Pathway is the highest individual dose within the identified Critical Age group.

(3) Maximum dose is a summation of the fish, drinking water and shoreline sediment pathways.

Section 4 - Page 3

Page 2 of 3 GASEOUS RELEASE PATHWAY IODINE, PARTICULATE, and TRITIUM Organ Environmental or Effluent Data Critical Age (1)

Critical Pathway (2)

Location Maximum Dose (3)

(mrem)

Skin Environmental 0.00E+00 Skin Effluent 0.5 mi S 0.00E+00 Bone Environmental Child Vegetation 201 (0.53 mi NE) 4.92E-01 Bone Effluent 0.5 mi S 0.00E+00 Liver Environmental Child Vegetation 201 (0.53 mi NE) 4.71E-01 Liver Effluent Child Vegetation 0.5 mi S 5.95E-01 T. Body Environmental Adult Vegetation 201 (0.53 mi NE) 2.65E-01 T. Body Effluent Child Vegetation 0.5 mi S 5.95E-01 Thyroid Environmental 0.00E+00 Thyroid Effluent Child Vegetation 0.5 mi S 5.95E-01 Kidney Environmental Child Vegetation 201 (0.53 mi NE) 1.54E-01 Kidney Effluent Child Vegetation 0.5 mi S 5.95E-01 Lung Environmental Child Vegetation 201 (0.53 mi NE) 5.52E-02 Lung Effluent Child Vegetation 0.5 mi S 5.95E-01 GI-LLI Environmental Adult Vegetation 201 (0.53 mi NE) 7.82E-03 GI-LLI Effluent Child Vegetation 0.5 mi S 5.95E-01 (1) Critical Age is the highest total dose (all pathways) to an age group.

(2) Critial Pathway is the highest individual dose within the identified Critical Age group.

(3) Maximum dose is a summation of the ground/plane, inhalation, milk and vegetation pathways.

Section 4 - Page 4

Page 3 of 3 NOBLE GAS Air Dose Environmental or Effluent Data Critical Age Critical Pathway Location Maximum Dose (mrad)

Beta Environmental Not Sampled Beta Effluent N/A Noble Gas 0.5 mi. NNE 1.74E-02 Gamma Environmental Not Sampled Gamma Effluent N/A Noble Gas 0.5 mi. NNE 3.86E-02 Section 4 - Page 5

TABLE 4.1-B Maximum Individual Dose for 2006 based on Environmental Measurements (mrem) for Catawba Nuclear Station Age Sample Medium Bone Liver T. Body Thyroid Kidney Lung GI-LLI Skin Infant Airborne 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Drinking Water 0.00E+00 8.42E-02 8.42E-02 8.42E-02 8.42E-02 8.42E-02 8.42E-02 0.00E+00 Milk 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TOTAL 0.00E+00 8.42E-02 8.42E-02 8.42E-02 8.42E-02 8.42E-02 8.42E-02 0.00E+00 Child Airborne 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Drinking Water 0.00E+00 8.57E-02 8.57E-02 8.57E-02 8.57E-02 8.57E-02 8.57E-02 0.00E+00 Milk 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Broadleaf Vegetation 4.92E-01 4.71E-01 6.95E-02 0.00E+00 1.54E-01 5.52E-02 2.95E-03 0.00E+00 Fish 3.25E-02 5.14E-02 2.49E-02 2.03E-02 3.05E-02 2.40E-02 2.05E-02 0.00E+00 Shoreline Sediment 0.00E+00 0.00E+00 2.54E-04 0.00E+00 0.00E+00 0.00E+00 0.00E+00 2.98E-04 TOTAL 5.25E-01 6.08E-01 1.80E-01 1.06E-01 2.70E-01 1.65E-01 1.09E-01 2.98E-04 Teen Airborne 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Drinking Water 0.00E+00 4.48E-02 4.48E-02 4.48E-02 4.48E-02 4.48E-02 4.48E-02 0.00E+00 Milk 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Broadleaf Vegetation 2.72E-01 3.62E-01 1.26E-01 0.00E+00 1.23E-01 4.79E-02 5.16E-03 0.00E+00 Fish 2.58E-02 5.89E-02 3.66E-02 2.46E-02 3.63E-02 2.91E-02 2.51E-02 0.00E+00 Shoreline Sediment 0.00E+00 0.00E+00 1.21E-03 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1.43E-03 TOTAL 2.98E-01 4.66E-01 2.09E-01 6.94E-02 2.04E-01 1.22E-01 7.51E-02 1.43E-03 Adult Airborne 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Drinking Water 0.00E+00 6.35E-02 6.35E-02 6.35E-02 6.35E-02 6.35E-02 6.35E-02 0.00E+00 Milk 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Broadleaf Vegetation 2.95E-01 4.04E-01 2.65E-01 0.00E+00 1.37E-01 4.56E-02 7.82E-03 0.00E+00 Fish 2.41E-02 6.49E-02 5.36E-02 3.20E-02 4.32E-02 3.57E-02 3.26E-02 0.00E+00 Shoreline Sediment 0.00E+00 0.00E+00 2.17E-04 0.00E+00 0.00E+00 0.00E+00 0.00E+00 2.56E-04 TOTAL 3.19E-01 5.32E-01 3.82E-01 9.55E-02 2.44E-01 1.45E-01 1.04E-01 2.56E-04 Note: Dose tables are provided for sample media displaying positive nuclide occurrence.

Section 4 - Page 6

Catawba Nuclear Station Dose from Drinking Water Pathway for 2006 Data Maximum Exposed Infant Infant Dose from Drinking Water Pathway (mrem) = Usage (l) x Dose Factor (mrem/pCi ingested) x Concentration (pCi/l)

Usage (intake in one year) =

330 l Highest Annual Net Mean Ingestion Dose Factor Concentration Dose (mrem)

Indicator Water Radionuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI Location (pCi/l)

Bone Liver T. Body Thyroid Kidney Lung GI-LLI Mn-54 NO DATA 1.99E-05 4.51E-06 NO DATA 4.41E-06 NO DATA 7.31E-06 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Co-58 NO DATA 3.60E-06 8.98E-06 NO DATA NO DATA NO DATA 8.97E-06 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Fe-59 3.08E-05 5.38E-05 2.12E-05 NO DATA NO DATA 1.59E-05 2.57E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Co-60 NO DATA 1.08E-05 2.55E-05 NO DATA NO DATA NO DATA 2.57E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Zn-65 1.84E-05 6.31E-05 2.91E-05 NO DATA 3.06E-05 NO DATA 5.33E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Nb-95 4.20E-08 1.73E-08 1.00E-08 NO DATA 1.24E-08 NO DATA 1.46E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Zr-95 2.06E-07 5.02E-08 3.56E-08 NO DATA 5.41E-08 NO DATA 2.50E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 I-131 3.59E-05 4.23E-05 1.86E-05 1.39E-02 4.94E-05 NO DATA 1.51E-06 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Cs-134 3.77E-04 7.03E-04 7.10E-05 NO DATA 1.81E-04 7.42E-05 1.91E-06 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Cs-137 5.22E-04 6.11E-04 4.33E-05 NO DATA 1.64E-04 6.64E-05 1.91E-06 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BaLa-140 1.71E-04 1.71E-07 8.81E-06 NO DATA 4.06E-08 1.05E-07 4.20E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 H-3 NO DATA 3.08E-07 3.08E-07 3.08E-07 3.08E-07 3.08E-07 3.08E-07 214 828 0.00E+00 8.42E-02 8.42E-02 8.42E-02 8.42E-02 8.42E-02 8.42E-02 Dose Commitment (mrem) =

0.00E+00 8.42E-02 8.42E-02 8.42E-02 8.42E-02 8.42E-02 8.42E-02 Section 4 - Page 7

Catawba Nuclear Station Dose from Drinking Water Pathway for 2006 Data Maximum Exposed Child Child Dose from Drinking Water Pathway (mrem) = Usage (l) x Dose Factor (mrem/pCi ingested) x Concentration (pCi/l)

Usage (intake in one year) =

510 l Highest Annual Net Mean Ingestion Dose Factor Concentration Dose (mrem)

Indicator Water Radionuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI Location (pCi/l)

Bone Liver T. Body Thyroid Kidney Lung GI-LLI Mn-54 NO DATA 1.07E-05 2.85E-06 NO DATA 3.00E-06 NO DATA 8.98E-06 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Co-58 NO DATA 1.80E-06 5.51E-06 NO DATA NO DATA NO DATA 1.05E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Fe-59 1.65E-05 2.67E-05 1.33E-05 NO DATA NO DATA 7.74E-06 2.78E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 C0-60 NO DATA 5.29E-06 1.56E-05 NO DATA NO DATA NO DATA 2.93E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Zn-65 1.37E-05 3.65E-05 2.27E-05 NO DATA 2.30E-05 NO DATA 6.41E-06 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Nb-95 2.25E-08 8.76E-09 6.26E-09 NO DATA 8.23E-09 NO DATA 1.62E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Zr-95 1.16E-07 2.55E-08 2.27E-08 NO DATA 3.65E-08 NO DATA 2.66E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 I-131 1.72E-05 1.73E-05 9.83E-06 5.72E-03 2.84E-05 NO DATA 1.54E-06 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Cs-134 2.34E-04 3.84E-04 8.10E-05 NO DATA 1.19E-04 4.27E-05 2.07E-06 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Cs-137 3.27E-04 3.13E-04 4.62E-05 NO DATA 1.02E-04 3.67E-05 1.96E-06 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BaLa-140 8.31E-05 7.28E-08 4.85E-06 NO DATA 2.37E-08 4.34E-08 4.21E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 H-3 NO DATA 2.03E-07 2.03E-07 2.03E-07 2.03E-07 2.03E-07 2.03E-07 214 828 0.00E+00 8.57E-02 8.57E-02 8.57E-02 8.57E-02 8.57E-02 8.57E-02 Dose Commitment (mrem) =

0.00E+00 8.57E-02 8.57E-02 8.57E-02 8.57E-02 8.57E-02 8.57E-02 Section 4 - Page 8

Catawba Nuclear Station Dose from Broadleaf Vegetation Pathway for 2006 Data Maximum Exposed Child Child Dose from Vegetation Pathway (mrem) = Usage (kg) x Dose Factor (mrem/pCi ingested) x Concentration (pCi/kg)

Usage (intake in one year) =

26 kg Highest Annual Net Mean Ingestion Dose Factor Concentration Dose (mrem)

Indicator Food Radionuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI Location (pCi/kg)

Bone Liver T. Body Thyroid Kidney Lung GI-LLI I-131 1.72E-05 1.73E-05 9.83E-06 5.72E-03 2.84E-05 NO DATA 1.54E-06 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Cs-134 2.34E-04 3.84E-04 8.10E-05 NO DATA 1.19E-04 4.27E-05 2.07E-06 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Cs-137 3.27E-04 3.13E-04 4.62E-05 NO DATA 1.02E-04 3.67E-05 1.96E-06 201 57.9 4.92E-01 4.71E-01 6.95E-02 0.00E+00 1.54E-01 5.52E-02 2.95E-03 Dose Commitment (mrem) =

4.92E-01 4.71E-01 6.95E-02 0.00E+00 1.54E-01 5.52E-02 2.95E-03 Section 4 - Page 9

Catawba Nuclear Station Dose from Fish Pathway for 2006 Data Maximum Exposed Child Child Dose from Fish Pathway (mrem) = Usage (kg) x Dose Factor (mrem/pCi ingested) x Concentration (pCi/kg)

H-3 Concentration in Fish = Surface Water pCi/l x Bioaccumulation Factor 0.9 pCi/kg per pCi/l = 16117 pCi/l x 0.9 = 14505 pCi/kg Usage (intake in one year) =

6.9 kg Highest Annual Net Mean Ingestion Dose Factor Concentration Dose (mrem)

Indicator Fish Radionuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI Location (pCi/kg)

Bone Liver T. Body Thyroid Kidney Lung GI-LLI Mn-54 NO DATA 1.07E-05 2.85E-06 NO DATA 3.00E-06 NO DATA 8.98E-06 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Co-58 NO DATA 1.80E-06 5.51E-06 NO DATA NO DATA NO DATA 1.05E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Fe-59 1.65E-05 2.67E-05 1.33E-05 NO DATA NO DATA 7.74E-06 2.78E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 C0-60 NO DATA 5.29E-06 1.56E-05 NO DATA NO DATA NO DATA 2.93E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Zn-65 1.37E-05 3.65E-05 2.27E-05 NO DATA 2.30E-05 NO DATA 6.41E-06 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Cs-134 2.34E-04 3.84E-04 8.10E-05 NO DATA 1.19E-04 4.27E-05 2.07E-06 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Cs-137 3.27E-04 3.13E-04 4.62E-05 NO DATA 1.02E-04 3.67E-05 1.96E-06 208 14.4 3.25E-02 3.11E-02 4.59E-03 0.00E+00 1.01E-02 3.65E-03 1.95E-04 H-3 NO DATA 2.03E-07 2.03E-07 2.03E-07 2.03E-07 2.03E-07 2.03E-07 208 14505 0.00E+00 2.03E-02 2.03E-02 2.03E-02 2.03E-02 2.03E-02 2.03E-02 Dose Commitment (mrem) =

3.25E-02 5.14E-02 2.49E-02 2.03E-02 3.05E-02 2.40E-02 2.05E-02 Section 4 - Page 10

Catawba Nuclear Station Dose from Shoreline Sediment Pathway for 2006 Data Maximum Exposed Child Shoreline Recreation =

14 hr (in one year)

Shore Width Factor =

0.2 Sediment Surface Mass =

40 kg/m2 Child Dose from Shoreline Sediment Pathway (mrem) = Shoreline Recreation (hr) x External Dose Factor (mrem/hr per pCi/m2) x Shore Width Factor x Sediment Surface Mass (kg/m2) x Sediment Concentration (pCi/kg)

External Dose Factor Standing Highest Annual Net Dose on Contaminated Ground Mean Concentration (mrem/hr per pCi/m2)

Indicator Sediment (mrem)

Radionuclide T. Body Skin Location (pCi/kg)

T. Body Skin Mn-54 5.80E-09 6.80E-09 ALL 0.00 0.00E+00 0.00E+00 Co-58 7.00E-09 8.20E-09 208-1S 54.0 4.23E-05 4.96E-05 Co-60 1.70E-08 2.00E-08 208-1S 111 2.11E-04 2.49E-04 Cs-134 1.20E-08 1.40E-08 ALL 0.00 0.00E+00 0.00E+00 Cs-137 4.20E-09 4.90E-09 ALL 0.00 0.00E+00 0.00E+00 Dose Commitment (mrem) =

2.54E-04 2.98E-04 Section 4 - Page 11

Catawba Nuclear Station Dose from Drinking Water Pathway for 2006 Data Maximum Exposed Teen Teen Dose from Drinking Water Pathway (mrem) = Usage (l) x Dose Factor (mrem/pCi ingested) x Concentration (pCi/l)

Usage (intake in one year) =

510 l Highest Annual Net Mean Ingestion Dose Factor Concentration Dose (mrem)

Indicator Water Radionuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI Location (pCi/l)

Bone Liver T. Body Thyroid Kidney Lung GI-LLI Mn-54 NO DATA 5.90E-06 1.17E-06 NO DATA 1.76E-06 NO DATA 1.21E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Co-58 NO DATA 9.72E-07 2.24E-06 NO DATA NO DATA NO DATA 1.34E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Fe-59 5.87E-06 1.37E-05 5.29E-06 NO DATA NO DATA 4.32E-06 3.24E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Co-60 NO DATA 2.81E-06 6.33E-06 NO DATA NO DATA NO DATA 3.66E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Zn-65 5.76E-06 2.00E-05 9.33E-06 NO DATA 1.28E-05 NO DATA 8.47E-06 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Nb-95 8.22E-09 4.56E-09 2.51E-09 NO DATA 4.42E-09 NO DATA 1.95E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Zr-95 4.12E-08 1.30E-08 8.94E-09 NO DATA 1.91E-08 NO DATA 3.00E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 I-131 5.85E-06 8.19E-06 4.40E-06 2.39E-03 1.41E-05 NO DATA 1.62E-06 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Cs-134 8.37E-05 1.97E-04 9.14E-05 NO DATA 6.26E-05 2.39E-05 2.45E-06 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Cs-137 1.12E-04 1.49E-04 5.19E-05 NO DATA 5.07E-05 1.97E-05 2.12E-06 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BaLa-140 2.84E-05 3.48E-08 1.83E-06 NO DATA 1.18E-08 2.34E-08 4.38E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 H-3 NO DATA 1.06E-07 1.06E-07 1.06E-07 1.06E-07 1.06E-07 1.06E-07 214 828 0.00E+00 4.48E-02 4.48E-02 4.48E-02 4.48E-02 4.48E-02 4.48E-02 Dose Commitment (mrem)=

0.00E+00 4.48E-02 4.48E-02 4.48E-02 4.48E-02 4.48E-02 4.48E-02 Section 4 - Page 12

Catawba Nuclear Station Dose from Broadleaf Vegetation Pathway for 2006 Data Maximum Exposed Teen Teen Dose from Vegetation Pathway (mrem) = Usage (kg) x Dose Factor (mrem/pCi ingested) x Concentration (pCi/kg)

Usage (intake in one year) =

42 kg Highest Annual Net Mean Ingestion Dose Factor Concentration Dose (mrem)

Indicator Food Radionuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI Location (pCi/kg)

Bone Liver T. Body Thyroid Kidney Lung GI-LLI I-131 5.85E-06 8.19E-06 4.40E-06 2.39E-03 1.41E-05 NO DATA 1.62E-06 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Cs-134 8.37E-05 1.97E-04 9.14E-05 NO DATA 6.26E-05 2.39E-05 2.45E-06 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Cs-137 1.12E-04 1.49E-04 5.19E-05 NO DATA 5.07E-05 1.97E-05 2.12E-06 201 57.9 2.72E-01 3.62E-01 1.26E-01 0.00E+00 1.23E-01 4.79E-02 5.16E-03 Dose Commitment (mrem) =

2.72E-01 3.62E-01 1.26E-01 0.00E+00 1.23E-01 4.79E-02 5.16E-03 Section 4 - Page 13

Catawba Nuclear Station Dose from Fish Pathway for 2006 Data Maximum Exposed Teen Teen Dose from Fish Pathway (mrem) = Usage (kg) x Dose Factor (mrem/pCi ingested) x Concentration (pCi/kg)

H-3 Concentration in Fish = Surface Water pCi/l x Bioaccumulation Factor 0.9 pCi/kg per pCi/l = 16117 pCi/l x 0.9 = 14505 pCi/kg Usage (intake in one year) =

16 kg Highest Annual Ingestion Dose Factor Net Mean Dose (mrem)

Concentration Radionuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI Location (pCi/kg)

Bone Liver T. Body Thyroid Kidney Lung GI-LLI Mn-54 NO DATA 5.90E-06 1.17E-06 NO DATA 1.76E-06 NO DATA 1.21E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Co-58 NO DATA 9.72E-07 2.24E-06 NO DATA NO DATA NO DATA 1.34E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Fe-59 5.87E-06 1.37E-05 5.29E-06 NO DATA NO DATA 4.32E-06 3.24E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Co-60 NO DATA 2.81E-06 6.33E-06 NO DATA NO DATA NO DATA 3.66E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Zn-65 5.76E-06 2.00E-05 9.33E-06 NO DATA 1.28E-05 NO DATA 8.47E-06 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Cs-134 8.37E-05 1.97E-04 9.14E-05 NO DATA 6.26E-05 2.39E-05 2.45E-06 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Cs-137 1.12E-04 1.49E-04 5.19E-05 NO DATA 5.07E-05 1.97E-05 2.12E-06 208 14.4 2.58E-02 3.43E-02 1.20E-02 0.00E+00 1.17E-02 4.54E-03 4.88E-04 H-3 NO DATA 1.06E-07 1.06E-07 1.06E-07 1.06E-07 1.06E-07 1.06E-07 208 14505 0.00E+00 2.46E-02 2.46E-02 2.46E-02 2.46E-02 2.46E-02 2.46E-02 Dose Commitment (mrem) =

2.58E-02 5.89E-02 3.66E-02 2.46E-02 3.63E-02 2.91E-02 2.51E-02 Section 4 - Page 14

Catawba Nuclear Station Dose from Shoreline Sediment Pathway for 2006 Data Maximum Exposed Teen Shoreline Recreation =

67 hr (in one year)

Shore Width Factor =

0.2 Sediment Surface Mass =

40 kg/m2 Teen Dose from Shoreline Sediment Pathway (mrem) = Shoreline Recreation (hr) x External Dose Factor (mrem/hr per pCi/m2) x Shore Width Factor x Sediment Surface Mass (kg/m2) x Sediment Concentration (pCi/kg)

External Dose Factor Standing Highest Annual Net Dose on Contaminated Ground Mean Concentration (mrem/hr per pCi/m2)

Indicator Sediment (mrem)

Radionuclide T. Body Skin Location (pCi/kg)

T. Body Skin Mn-54 5.80E-09 6.80E-09 ALL 0.00 0.00E+00 0.00E+00 Co-58 7.00E-09 8.20E-09 208-1S 54.0 2.03E-04 2.37E-04 Co-60 1.70E-08 2.00E-08 208-1S 111 1.01E-03 1.19E-03 Cs-134 1.20E-08 1.40E-08 ALL 0.00 0.00E+00 0.00E+00 Cs-137 4.20E-09 4.90E-09 ALL 0.00 0.00E+00 0.00E+00 Dose Commitment (mrem) =

1.21E-03 1.43E-03 Section 4 - Page 15

Catawba Nuclear Station Dose from Drinking Water Pathway for 2006 Data Maximum Exposed Adult Adult Dose from Drinking Water Pathway (mrem) = Usage (l) x Dose Factor (mrem/pCi ingested) x Concentration (pCi/l)

Usage (intake in one year) =

730 l Highest Annual Net Mean Ingestion Dose Factor Concentration Dose (mrem)

Indicator Water Radionuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI Location (pCi/l)

Bone Liver T. Body Thyroid Kidney Lung GI-LLI Mn-54 NO DATA 4.57E-06 8.72E-07 NO DATA 1.36E-06 NO DATA 1.40E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Co-58 NO DATA 7.45E-07 1.67E-06 NO DATA NO DATA NO DATA 1.51E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Fe-59 4.34E-06 1.02E-05 3.91E-06 NO DATA NO DATA 2.85E-06 3.40E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Co-60 NO DATA 2.14E-06 4.72E-06 NO DATA NO DATA NO DATA 4.02E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Zn-65 4.84E-06 1.54E-05 6.96E-06 NO DATA 1.03E-05 NO DATA 9.70E-06 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Nb-95 6.22E-09 3.46E-09 1.86E-09 NO DATA 3.42E-09 NO DATA 2.10E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Zr-95 3.04E-08 9.75E-09 6.60E-09 NO DATA 1.53E-08 NO DATA 3.09E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 I-131 4.16E-06 5.95E-06 3.41E-06 1.95E-03 1.02E-05 NO DATA 1.57E-06 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Cs-134 6.22E-05 1.48E-04 1.21E-04 NO DATA 4.79E-05 1.59E-05 2.59E-06 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Cs-137 7.97E-05 1.09E-04 7.14E-05 NO DATA 3.70E-05 1.23E-05 2.11E-06 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BaLa-140 2.03E-05 2.55E-08 1.33E-06 NO DATA 8.67E-09 1.46E-08 4.18E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 H-3 NO DATA 1.05E-07 1.05E-07 1.05E-07 1.05E-07 1.05E-07 1.05E-07 214 828 0.00E+00 6.35E-02 6.35E-02 6.35E-02 6.35E-02 6.35E-02 6.35E-02 Dose Commitment (mrem) =

0.00E+00 6.35E-02 6.35E-02 6.35E-02 6.35E-02 6.35E-02 6.35E-02 Section 4 - Page 16

Catawba Nuclear Station Dose from Broadleaf Vegetation Pathway for 2006 Data Maximum Exposed Adult Adult Dose from Vegetation (mrem) = Usage (kg) x Dose Factor (mrem/pCi ingested) x Concentration (pCi/kg)

Usage (intake in one year) =

64 kg Highest Annual Net Mean Ingestion Dose Factor Concentration Dose (mrem)

Indicator Food Radionuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI Location (pCi/kg)

Bone Liver T. Body Thyroid Kidney Lung GI-LLI I-131 4.16E-06 5.95E-06 3.41E-06 1.95E-03 1.02E-05 NO DATA 1.57E-06 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Cs-134 6.22E-05 1.48E-04 1.21E-04 NO DATA 4.79E-05 1.59E-05 2.59E-06 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Cs-137 7.97E-05 1.09E-04 7.14E-05 NO DATA 3.70E-05 1.23E-05 2.11E-06 201 57.9 2.95E-01 4.04E-01 2.65E-01 0.00E+00 1.37E-01 4.56E-02 7.82E-03 Dose Commitment (mrem) =

2.95E-01 4.04E-01 2.65E-01 0.00E+00 1.37E-01 4.56E-02 7.82E-03 Section 4 - Page 17

Catawba Nuclear Station Dose from Fish Pathway for 2006 Data Maximum Exposed Adult Adult Dose from Fish Pathway (mrem) = Usage (kg) x Dose Factor (mrem/pCi ingested) x Concentration (pCi/kg)

H-3 Concentration in Fish = Surface Water pCi/l x Bioaccumulation Factor 0.9 pCi/kg per pCi/l = 16117 pCi/l x 0.9 = 14505 pCi/kg Usage (intake in one year) =

21 kg Highest Annual Net Mean Ingestion Dose Factor Concentration Dose (mrem)

Radionuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI Location (pCi/kg)

Bone Liver T. Body Thyroid Kidney Lung GI-LLI Mn-54 NO DATA 4.57E-06 8.72E-07 NO DATA 1.36E-06 NO DATA 1.40E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Co-58 NO DATA 7.45E-07 1.67E-06 NO DATA NO DATA NO DATA 1.51E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Fe-59 4.34E-06 1.02E-05 3.91E-06 NO DATA NO DATA 2.85E-06 3.40E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Co-60 NO DATA 2.14E-06 4.72E-06 NO DATA NO DATA NO DATA 4.02E-05 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Zn-65 4.84E-06 1.54E-05 6.96E-06 NO DATA 1.03E-05 NO DATA 9.70E-06 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Cs-134 6.22E-05 1.48E-04 1.21E-04 NO DATA 4.79E-05 1.59E-05 2.59E-06 ALL 0.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Cs-137 7.97E-05 1.09E-04 7.14E-05 NO DATA 3.70E-05 1.23E-05 2.11E-06 208 14.4 2.41E-02 3.30E-02 2.16E-02 0.00E+00 1.12E-02 3.72E-03 6.38E-04 H-3 NO DATA 1.05E-07 1.05E-07 1.05E-07 1.05E-07 1.05E-07 1.05E-07 208 14505 0.00E+00 3.20E-02 3.20E-02 3.20E-02 3.20E-02 3.20E-02 3.20E-02 Dose Commitment (mrem) =

2.41E-02 6.49E-02 5.36E-02 3.20E-02 4.32E-02 3.57E-02 3.26E-02 Section 4 - Page 18

Catawba Nuclear Station Dose from Shoreline Sediment Pathway for 2006 Data Maximum Exposed Adult Shoreline Recreation =

12 hr (in one year)

Shore Width Factor =

0.2 Sediment Surface Mass =

40 kg/m2 Adult Dose from Shoreline Sediment Pathway (mrem) = Shoreline Recreation (hr) x External Dose Factor (mrem/hr per pCi/m2) x Shore Width Factor x Sediment Surface Mass (kg/m2) x Sediment Concentration (pCi/kg)

External Dose Factor Standing Highest Annual Net Dose on Contaminated Ground Mean Concentration (mrem)

(mrem/hr per pCi/m2)

Indicator Sediment Radionuclide T. Body Skin Location (pCi/kg)

T. Body Skin Mn-54 5.80E-09 6.80E-09 ALL 0.00 0.00E+00 0.00E+00 Co-58 7.00E-09 8.20E-09 208-1S 54.0 3.63E-05 4.25E-05 Co-60 1.70E-08 2.00E-08 208-1S 111 1.81E-04 2.13E-04 Cs-134 1.20E-08 1.40E-08 ALL 0.00 0.00E+00 0.00E+00 Cs-137 4.20E-09 4.90E-09 ALL 0.00 0.00E+00 0.00E+00 Dose Commitment (mrem) =

2.17E-04 2.56E-04 Section 4 - Page 19

Section 5 - Page 1 5.0 QUALITY ASSURANCE 5.1 SAMPLE COLLECTION EnRad Laboratories, Fisheries, and Aquatic Ecology performed the environmental sample collections as specified by approved sample collection procedures.

5.2 SAMPLE ANALYSIS EnRad Laboratories performed the environmental sample analyses as specified by approved analysis procedures. EnRad Laboratories is located in Huntersville, North

Carolina, at Duke Energy Corporations Environmental Center.

5.3 DOSIMETRY ANALYSIS The Radiation Dosimetry and Records group performed environmental dosimetry measurements as specified by approved dosimetry analysis procedures.

5.4 LABORATORY EQUIPMENT QUALITY ASSURANCE 5.4.1 DAILY QUALITY CONTROL EnRad Laboratories has an internal quality assurance program which monitors each type of instrumentation for reliability and accuracy. Daily quality control checks ensure that instruments are in proper working order and these checks are used to monitor instrument performance.

5.4.2 CALIBRATION VERIFICATION National Institute of Standards and Technology (NIST) standards that represent counting geometries are analyzed as unknowns at various frequencies ranging from weekly to annually to verify that efficiency calibrations are valid. The frequency is dependent upon instrument use and performance. Investigations are performed and documented should calibration verification data fall out of limits.

Duke Energy Corporations Environmental Center

Section 5 - Page 2 5.4.3 BATCH PROCESSING Method quality control samples are analyzed with sample analyses that are processed in batches. These include gross beta in drinking water and tritium analyses.

5.5 DUKE ENERGY INTERCOMPARISON PROGRAM EnRad Laboratories participated in the Duke Energy Nuclear Generation Department Intercomparison Program during 2006. Interlaboratory cross-check standards, including, Marinelli beakers, air filters, air cartridges, gross beta on smears, and tritium in water samples were analyzed at various times of the year by the four counting laboratories in Duke Energy for this program. A summary of these Intercomparison Reports for 2006 is documented in Table 5.0-A.

5.6 DUKE ENERGY AUDITS The Catawba Radiation Protection Section was audited by the Quality Assurance Group in 2006. There were no REMP recommendations as a result of the audit.

EnRad Laboratories was audited by the Quality Assurance Group in 2006. There were no REMP recommendations as a result of the audit.

5.7 U.S. NUCLEAR REGULATORY COMMISSION INSPECTIONS The Catawba Nuclear Station Radiological Environmental Monitoring Program was not audited by the NRC in 2006. The program was audited in 2005 (Reference 6.12).

There were no findings or issues identified by the audit.

5.8 STATE OF SOUTH CAROLINA INTERCOMPARISON PROGRAM EnRad Laboratories routinely participates with the Bureau of Radiological Health of the States Department of Health and Environmental Control (DHEC) in an intercomparison program. EnRad Laboratories sends air, water, milk, vegetation, sediment, and fish samples which have been collected to the State of South Carolina DHEC Laboratory for intercomparison analysis.

5.9 TLD INTERCOMPARISON PROGRAM 5.9.1 NUCLEAR TECHNOLOGY SERVICES INTERCOMPARISON PROGRAM Radiation Dosimetry and Records participates in a quarterly TLD intercomparison program administered by Nuclear Technology Services, Inc.

of Roswell, GA. Nuclear Technology Services irradiates environmental

Section 5 - Page 3 dosimeters quarterly and sends them to the Radiation Dosimetry and Records group for analysis of the unknown estimated delivered exposure. A summary of the Nuclear Technology Services Intercomparison Report is documented in Table 5.0-B.

5.9.2 STATE OF NORTH CAROLINA INTERCOMPARISON PROGRAM Radiation Dosimetry and Records routinely participates in a TLD intercomparison program. The State of North Carolina Radiation Protection Section irradiates environmental dosimeters and sends them to the Radiation Dosimetry and Records group for analysis of the unknown estimated delivered exposure. A summary of the State of North Carolina Environmental Dosimetry Intercomparison Report for 2006 is documented in Table 5.0-B.

5.9.3 INTERNAL CROSSCHECK (DUKE ENERGY)

Radiation Dosimetry and Records participates in a quarterly TLD intracomparison program administered internally by the Dosimetry Lab. The Dosimetry Lab Staff irradiates environmental dosimeters quarterly and submits them for analysis of the unknown estimated delivered exposure. A summary of the Internal Cross Check (Duke Energy) Result is documented in Table 5.0-B.

TABLE 5.0-A DUKE POWER COMPANY INTERLABORATORY COMPARISON PROGRAM 2006 CROSS-CHECK RESULTS FOR ENRAD LABORATORIES Cross-Check samples are normally analyzed a minimum of three times. A status of "3 Pass" indicates that all three analyses yielded results within the designated acceptance range. A status of "1 Pass" indicates that one analysis of the cross-check was performed.

Footnote explanations are included following this data table.

Gamma in Water 3.5 liters Reference Sample I.D.

Nuclide Acceptance Reference Mean Reported Cross Check Date Range Value Value Status pCi/l pCi/l pCi/l 3/20/2006 Q061GWS Cr-51 3.02 - 5.35 E5 4.02 E5 3.88 E5 3 Pass Co-57 1.37 - 2.42 E4 1.82 E4 1.86 E4 3 Pass Co-60 0.76 - 1.34 E5 1.01 E5 0.95 E5 3 Pass Sr-85 7.28 - 12.91 E4 9.71 E4 9.00 E4 3 Pass Y-88 1.27 - 2.25 E5 1.69 E5 1.62 E5 3 Pass Cd-109 3.72 - 6.60 E5 4.96 E5 4.97 E5 3 Pass Sn-113 6.65 - 11.80 E4 8.87 E4 8.60 E4 3 Pass Te-123M 1.62 - 2.86 E4 2.15 E4 2.09 E4 3 Pass Cs-137 6.30 - 11.17 E4 8.40 E4 7.69 E4 3 Pass 5/16/2006 Q062GWR Cr-51 0.94 - 1.67 E4 1.26 E4 1.26 E4 3 Pass Co-57 1.97 - 3.50 E2 2.63 E2 2.76 E2 3 Pass Co-60 0.98 - 1.75 E3 1.31 E3 1.30 E3 3 Pass Sr-85 1.39 - 2.47 E3 1.86 E3 1.82 E3 3 Pass Y-88 2.07 - 3.66 E3 2.76 E3 2.69 E3 3 Pass Cd-109 4.99 - 8.86 E3 6.66 E3 6.57 E3 3 Pass Sn-113 1.06 - 1.89 E3 1.42 E3 1.25 E3 3 Pass Te-123M 2.62 - 4.64 E2 3.49 E2 3.40 E2 3 Pass Cs-137 0.82 - 1.45 E3 1.09 E3 1.06 E3 3 Pass 10/11/2006 Q064GWS Cr-51 7.12 - 12.62 E4 9.49 E4 9.66 E4 3 Pass Mn-54 5.26 - 9.33 E4 7.02 E4 7.41 E4 3 Pass Co-58 4.17 - 7.39 E4 5.55 E4 5.66 E4 3 Pass Fe-59 1.42 - 2.53 E4 1.90 E4 2.01 E4 3 Pass Co-60 6.57 - 11.65 E4 8.76 E4 9.26 E4 3 Pass Zn-65 6.67 - 11.84 E4 8.90 E4 9.30 E4 3 Pass Cs-134 4.12 - 7.30 E4 5.49 E4 5.12 E4 3 Pass Cs-137 0.87 - 1.54 E5 1.16 E5 1.12 E5 3 Pass Ce-141 2.40 - 4.26 E4 3.20 E4 3.30 E4 3 Pass Section 5 - Page 4

Gamma in Water 1.0 liter Reference Sample I.D.

Nuclide Acceptance Reference Mean Reported Cross Check Date Range Value Value Status pCi/l pCi/l pCi/l 3/20/2006 Q061GWS Cr-51 3.02 - 5.35 E5 4.02 E5 3.70 E5 3 Pass Co-57 1.37 - 2.42 E4 1.82 E4 1.80 E4 3 Pass Co-60 0.76 - 1.34 E5 1.01 E5 0.92 E5 3 Pass Sr-85 7.28 - 12.91 E4 9.71 E4 8.73 E4 3 Pass Y-88 1.27 - 2.25 E5 1.69 E5 1.56 E5 3 Pass Cd-109 3.72 - 6.60 E5 4.96 E5 4.59 E5 3 Pass Sn-113 6.65 - 11.80 E4 8.87 E4 8.27 E4 3 Pass Te-123M 1.62 - 2.86 E4 2.15 E4 2.00 E4 3 Pass Cs-137 6.30 - 11.17 E4 8.40 E4 7.54 E4 3 Pass 5/16/2006 Q062GWR Cr-51 0.94 - 1.67 E4 1.26 E4 1.20 E4 3 Pass Co-57 1.97 - 3.50 E2 2.63 E2 2.64 E2 3 Pass Co-60 0.98 - 1.75 E3 1.31 E3 1.26 E3 3 Pass Sr-85 1.39 - 2.47 E3 1.86 E3 1.76 E3 3 Pass Y-88 2.07 - 3.66 E3 2.76 E3 2.58 E3 3 Pass Cd-109 4.99 - 8.86 E3 6.66 E3 6.34 E3 3 Pass Sn-113 1.06 - 1.89 E3 1.42 E3 1.17 E3 3 Pass Te-123M 2.62 - 4.64 E2 3.49 E2 3.02 E2 3 Pass Cs-137 0.82 - 1.45 E3 1.09 E3 0.99 E3 3 Pass 10/11/2006 Q064GWS Cr-51 7.12 - 12.62 E4 9.49 E4 9.42 E4 3 Pass Mn-54 5.26 - 9.33 E4 7.02 E4 7.38 E4 3 Pass Co-58 4.17 - 7.39 E4 5.55 E4 5.63 E4 3 Pass Fe-59 1.42 - 2.53 E4 1.90 E4 2.00 E4 3 Pass Co-60 6.57 - 11.65 E4 8.76 E4 8.73 E4 3 Pass Zn-65 6.67 - 11.84 E4 8.90 E4 9.26 E4 3 Pass Cs-134 4.12 - 7.30 E4 5.49 E4 5.02 E4 3 Pass Cs-137 0.87 - 1.54 E5 1.16 E5 1.12 E5 3 Pass Ce-141 2.40 - 4.26 E4 3.20 E4 3.25 E4 3 Pass Gamma in Water 0.5 liter Reference Sample I.D.

Nuclide Acceptance Reference Mean Reported Cross Check Date Range Value Value Status pCi/l pCi/l pCi/l 3/20/2006 Q061GWS Cr-51 3.02 - 5.35 E5 4.02 E5 3.76 E5 3 Pass Co-57 1.37 - 2.42 E4 1.82 E4 1.70 E4 3 Pass Co-60 0.76 - 1.34 E5 1.01 E5 0.92 E5 3 Pass Sr-85 7.28 - 12.91 E4 9.71 E4 8.50 E4 3 Pass Y-88 1.27 - 2.25 E5 1.69 E5 1.54 E5 3 Pass Cd-109 3.72 - 6.60 E5 4.96 E5 4.53 E5 3 Pass Sn-113 6.65 - 11.80 E4 8.87 E4 8.23 E4 3 Pass Te-123M 1.62 - 2.86 E4 2.15 E4 1.96 E4 3 Pass Cs-137 6.30 - 11.17 E4 8.40 E4 7.26 E4 3 Pass Section 5 - Page 5

Gamma in Water 0.5 liter, continued Reference Sample I.D.

Nuclide Acceptance Reference Mean Reported Cross Check Date Range Value Value Status pCi/l pCi/l pCi/l 10/11/2006 Q064GWS Cr-51 7.12 - 12.62 E4 9.49 E4 10.13 E4 3 Pass Mn-54 5.26 - 9.33 E4 7.02 E4 7.40 E4 3 Pass Co-58 4.17 - 7.39 E4 5.55 E4 5.64 E4 3 Pass Fe-59 1.42 - 2.53 E4 1.90 E4 2.08 E4 3 Pass Co-60 6.57 - 11.65 E4 8.76 E4 8.96 E4 3 Pass Zn-65 6.67 - 11.84 E4 8.90 E4 9.51 E4 3 Pass Cs-134 4.12 - 7.30 E4 5.49 E4 4.97 E4 3 Pass Cs-137 0.87 - 1.54 E5 1.16 E5 1.11 E5 3 Pass Ce-141 2.40 - 4.26 E4 3.20 E4 3.23 E4 3 Pass Gamma in Water 0.25 liter Reference Sample I.D.

Nuclide Acceptance Reference Mean Reported Cross Check Date Range Value Value Status pCi/l pCi/l pCi/l 5/16/2006 Q062GWR Cr-51 0.94 - 1.67 E4 1.26 E4 1.20 E4 3 Pass Co-57 1.95 - 3.55 E2 2.63 E2 2.66 E2 3 Pass Co-60 0.98 - 1.75 E3 1.31 E3 1.34 E3 3 Pass Sr-85 1.39 - 2.47 E3 1.86 E3 1.68 E3 3 Pass Y-88 2.07 - 3.66 E3 2.76 E3 2.61 E3 3 Pass Cd-109 4.66 - 9.52 E3 6.66 E3 6.60 E3 3 Pass Sn-113 1.06 - 1.89 E3 1.42 E3 1.14 E3 3 Pass Te-123M 2.58 - 4.71 E2 3.49 E2 2.96 E2 3 Pass Cs-137 0.82 - 1.45 E3 1.09 E3 1.00 E3 3 Pass 10/11/2006 Q064GWS Cr-51 7.12 - 12.62 E4 9.49 E4 9.80 E4 3 Pass Mn-54 5.26 - 9.33 E4 7.02 E4 7.50 E4 3 Pass Co-58 4.17 - 7.39 E4 5.55 E4 5.63 E4 3 Pass Fe-59 1.42 - 2.53 E4 1.90 E4 2.14 E4 3 Pass Co-60 6.57 - 11.65 E4 8.76 E4 8.93 E4 3 Pass Zn-65 6.67 - 11.84 E4 8.90 E4 9.60 E4 3 Pass Cs-134 4.12 - 7.30 E4 5.49 E4 4.91 E4 3 Pass Cs-137 0.87 - 1.54 E5 1.16 E5 1.12 E5 3 Pass Ce-141 2.40 - 4.26 E4 3.20 E4 3.29 E4 3 Pass Section 5 - Page 6

Gamma in Filter Reference Sample I.D.

Nuclide Acceptance Reference Mean Reported Cross Check Date Range Value Value Status pCi pCi pCi 2/24/2006 A20206-04 Cr-51 7.33 - 12.99 E4 9.77 E4 9.56 E4 3 Pass Mn-54 1.29 - 2.29 E4 1.72 E4 1.76 E4 3 Pass Co-57 Sample Contaminant Sample Contaminant 2.30 E2 N/A (1)

Co-58 1.82 - 3.23 E4 2.43 E4 2.35 E4 3 Pass Fe-59 1.76 - 3.13 E4 2.35 E4 2.32 E4 3 Pass Co-60 1.72 - 3.05 E4 2.29 E4 2.22 E4 3 Pass Zn-65 2.54 - 4.51 E4 3.39 E4 3.34 E4 3 Pass Cs-134 1.65 - 2.93 E4 2.20 E4 2.01 E4 3 Pass Cs-137 1.19 - 2.10 E4 1.58 E4 1.47 E4 3 Pass Ce-139 Sample Contaminant Sample Contaminant 3.99 E2 N/A (1)

Ce-141 2.47 - 4.38 E4 3.29 E4 3.16 E4 3 Pass 6/8/2006 E4980-37 Cr-51 1.41 - 3.04 E2 2.07 E2 1.98 E2 3 Pass Mn-54 0.88 - 1.56 E2 1.17 E2 1.16 E2 3 Pass Co-58 6.00 - 10.64 E1 8.00 E1 7.86 E1 3 Pass Fe-59 5.63 - 9.98 E1 7.50 E1 7.73 E1 3 Pass Co-60 0.77 - 1.37 E2 1.03 E2 1.05 E2 3 Pass Zn-65 1.11 - 1.97 E2 1.48 E2 1.40 E2 3 Pass Cd-109 Sample Contaminant Sample Contaminant Too Low to Quantify N/A (1)

Cs-134 0.76 - 1.34 E2 1.01 E2 0.91 E2 3 Pass Cs-137 7.05 - 12.50 E1 9.40 E1 8.72 E1 3 Pass Ce-139 Sample Contaminant Sample Contaminant 8.90 E0 N/A (1)

Ce-141 1.10 - 1.96 E2 1.47 E2 1.35 E2 3 Pass Iodine in Water Reference Sample I.D.

Nuclide Acceptance Reference Mean Reported Cross Check Date Range Value Value Status pCi/l pCi/l pCi/l 3/20/2006 Q061LIW1 I-131 2.42 - 4.30 E3 3.23 E3 3.31 E3 3 Pass 3/20/2006 Q061LIW2 I-131 N/A 0.00E+00 0.00E+00 3 Pass 3/20/2006 Q061LIW3 I-131 1.60 - 2.83 E3 2.13 E3 2.31 E3 3 Pass Iodine on Cartridge Reference Sample I.D.

Nuclide Acceptance Reference Mean Reported Cross Check Date Range Value Value Status pCi pCi pCi 2/24/2006 A20207-04 I-131 N/A N/A N/A N/A (2) 6/8/2006 E4981-37 I-131 4.88 - 8.65 E1 6.50 E1 7.31 E1 3 Pass Section 5 - Page 7

Beta in Water Reference Sample I.D.

Nuclide Acceptance Reference Mean Reported Cross Check Date Range Value Value Status pCi/l pCi/l pCi/l 6/8/2006 E4982-37 Beta 1.27 -2.25 E2 1.69 E2 1.65 E2 3 Pass Beta Smear Reference Sample I.D.

Nuclide Acceptance Reference Mean Reported Cross Check Date Range Value Value Status dpm dpm dpm 2/24/2006 A20204-04 Beta 1.18 - 2.09 E4 1.57 E4 1.59 E4 3 Pass 11/10/2006 A21058-04 Beta 1.02 - 1.81 E4 1.36 E4 1.32 E4 3 Pass Tritium in Water Reference Sample I.D.

Nuclide Acceptance Reference Mean Reported Cross Check Date Range Value Value Status pCi/l pCi/l pCi/l 3/21/2006 Q061TWSL1 H-3 1.52 - 2.70 E5 2.03 E5 1.99 E5 3 Pass 3/21/2006 Q061TWSL2 H-3 N/A 0.00E+00 0.00E+00 3 Pass 5/8/2006 Q062TWR1 H-3 N/A 0.00E+00 0.00E+00 3 Pass 5/8/2006 Q062TWR2 H-3 2.70 - 4.79 E3 3.60 E3 3.59 E3 3 Pass 5/8/2006 Q062TWR3 H-3 5.89 - 10.45 E2 7.86 E2 8.12 E2 3 Pass 9/13/2006 Q063TWSL1 H-3 0.77 - 1.37 E5 1.03 E5 1.03 E5 3 Pass 9/13/2006 Q063TWSL2 H-3 N/A 0.00E+00 0.00E+00 3 Pass Section 5 - Page 8

Section 5 - Page 9 Table 5.0-A Footnote Explanations (1)

Gamma in Filter, Sample ID A20206-04, Reference Date 2/24/2006 & Gamma in Filter, Sample ID E4980-37, Reference Date 6/8/2006 Co-57, Cd-109 and Ce-139 was identified and reported for two cross-check samples. Co-57 and Ce-139 was identified in gamma filter A20206-04 and Cd-109 and Ce-139 was identified in gamma filter E4980-37. The cross check supplier does not include these radionuclides on the certificates of analysis for these two cross-check samples. These radionuclides were determined to be inherent contaminants in the cross-check samples. PIP G-06-00421 written.

(2)

Iodine on Cartridge, Sample ID A20207-04, Reference Date 2/24/2006 Cross-check A20207-04 was not analyzed in a timely manner for reporting.

Cross-check data was not reported for this sample due to excessive sample decay.

PIP G-06-00246 written.

TABLE 5.0-B 2006 ENVIRONMENTAL DOSIMETER CROSS-CHECK RESULTS Nuclear Technology Services 1st Quarter 2006 2nd Quarter 2006 TLD Delivered Reported Bias Pass/Fail TLD Delivered Reported Bias Pass/Fail Number (mrem)

(mrem)

(% diff)

Criteria Pass/Fail Number (mrem)

(mrem)

(% diff)

Criteria Pass/Fail 102038 89 96.9 8.88

<+/-15%

Pass 102480 67 68.5 2.24

<+/-15%

Pass 102055 89 92.1 3.48

<+/-15%

Pass 102481 67 68.6 2.39

<+/-15%

Pass 102057 89 91.7 3.03

<+/-15%

Pass 102437 67 67.7 1.04

<+/-15%

Pass 102303 89 91.0 2.25

<+/-15%

Pass 102395 67 69.5 3.73

<+/-15%

Pass 102305 89 91.6 2.92

<+/-15%

Pass 102399 67 69.8 4.18

<+/-15%

Pass Average Bias (B) 4.11 Average Bias (B) 2.72 Standard Deviation (S) 2.70 Standard Deviation (S) 1.25 Measure Performance lBl+S 6.81

<15%

Pass Measure Performance lBl+S 3.97

<15%

Pass 3rd Quarter 2006 4th Quarter 2006 TLD Delivered Reported Bias Pass/Fail TLD Delivered Reported Bias Pass/Fail Number (mrem)

(mrem)

(% diff)

Criteria Pass/Fail Number (mrem)

(mrem)

(% diff)

Criteria Pass/Fail 102444 83.6 88.1 5.38

<+/-15%

Pass 100046 86.5 94.6 9.36

<+/-15%

Pass 102424 83.6 87.7 4.90

<+/-15%

Pass 100052 86.5 92.3 6.71

<+/-15%

Pass 102502 83.6 87.2 4.31

<+/-15%

Pass 100065 86.5 90.1 4.16

<+/-15%

Pass 102464 83.6 85.3 2.03

<+/-15%

Pass 100240 86.5 93.0 7.51

<+/-15%

Pass 102157 83.6 83.7 0.12

<+/-15%

Pass 100358 86.5 94.8 9.60

<+/-15%

Pass Average Bias (B) 3.35 Average Bias (B) 7.47 Standard Deviation (S) 2.22 Standard Deviation (S) 2.22 Measure Performance lBl+S 5.56

<15%

Pass Measure Performance lBl+S 9.68

<15%

Pass State of North Carolina, Division of Radiation Protection Spring 2006 Fall 2006 TLD Delivered Reported Bias Pass/Fail TLD Delivered Reported Bias Pass/Fail Number (mrem)

(mrem)

(% diff)

Criteria Pass/Fail Number (mrem)

(mrem)

(% diff)

Criteria Pass/Fail 100246 55.0 58.8 6.91

<+/-15%

Pass

<+/-15%

100243 55.0 61.6 12.00

<+/-15%

Pass NOTE: The Fall 2006 Environmental

<+/-15%

100241 55.0 58.0 5.45

<+/-15%

Pass Crosscheck was not administered

<+/-15%

100240 55.0 58.2 5.82

<+/-15%

Pass by the State of North Carolina

<+/-15%

100239 55.0 59.6 8.36

<+/-15%

Pass Division of Radiation Protection.

<+/-15%

100236 55.0 57.2 4.00

<+/-15%

Pass

<+/-15%

100232 55.0

<+/-15%

<+/-15%

100217 55.0 56.7 3.09

<+/-15%

Pass

<+/-15%

Average Bias (B) 6.52 Average Bias (B)

Standard Deviation (S) 2.98 Standard Deviation (S)

Measure Performance lBl+S 9.50

<15%

Pass Measure Performance lBl+S

<15%

    • TLD Damaged Section 5 - Page 10

Internal Crosscheck (Duke Energy) 1st Quarter 2006 2nd Quarter 2006 TLD Delivered Reported Bias Pass/Fail TLD Delivered Reported Bias Pass/Fail Number (mrem)

(mrem)

(% diff)

Criteria Pass/Fail Number (mrem)

(mrem)

(% diff)

Criteria Pass/Fail 102261 49.0 48.6

-0.82

<+/-15%

Pass 100007 61.0 58.4

-4.23

<+/-15%

Pass 102244 49.0 49.1 0.13

<+/-15%

Pass 100021 61.0 58.8

-3.54

<+/-15%

Pass 102436 49.0 46.9

-4.31

<+/-15%

Pass 100035 61.0 60.2

-1.38

<+/-15%

Pass 102318 49.0 47.0

-4.17

<+/-15%

Pass 100072 61.0 60.2

-1.39

<+/-15%

Pass 102482 49.0 48.3

-1.39

<+/-15%

Pass 100168 61.0 60.8

-0.30

<+/-15%

Pass 102292 49.0 48.1

-1.93

<+/-15%

Pass 100123 61.0 59.5

-2.43

<+/-15%

Pass 102321 49.0 46.6

-4.86

<+/-15%

Pass 100734 61.0 59.4

-2.55

<+/-15%

Pass 102346 49.0 47.2

-3.70

<+/-15%

Pass 100108 61.0 60.6

-0.61

<+/-15%

Pass 102479 49.0 46.3

-5.46

<+/-15%

Pass 100049 61.0 58.6

-3.94

<+/-15%

Pass 102293 49.0 47.3

-3.45

<+/-15%

Pass 100169 61.0 58.2

-4.65

<+/-15%

Pass Average Bias (B)

-3.00 Average Bias (B)

-2.50 Standard Deviation (S) 1.87 Standard Deviation (S) 1.55 Measure Performance lBl+S 4.87

<15%

Pass Measure Performance lBl+S 4.05

<15%

Pass 3rd Quarter 2006 4th Quarter 2006 TLD Delivered Reported Bias Pass/Fail TLD Delivered Reported Bias Pass/Fail Number (mrem)

(mrem)

(% diff)

Criteria Pass/Fail Number (mrem)

(mrem)

(% diff)

Criteria Pass/Fail 101281 61.0 64.6 5.84

<+/-15%

Pass 101024 60.0 62.0 3.28

<+/-15%

Pass 101209 61.0 62.6 2.60

<+/-15%

Pass 101190 60.0 60.3 0.50

<+/-15%

Pass 101203 61.0 63.3 3.77

<+/-15%

Pass 101191 60.0 60.3 0.51

<+/-15%

Pass 101202 61.0 63.7 4.36

<+/-15%

Pass 101195 60.0 60.8 1.32

<+/-15%

Pass 101369 61.0 63.8 4.61

<+/-15%

Pass 101038 60.0 62.6 4.27

<+/-15%

Pass 101198 61.0 65.5 7.40

<+/-15%

Pass 100026 60.0 61.9 3.19

<+/-15%

Pass 101177 61.0 61.6 0.98

<+/-15%

Pass 100096 60.0 60.2 0.32

<+/-15%

Pass 101239 61.0 62.9 3.13

<+/-15%

Pass 100522 60.0 62.5 4.21

<+/-15%

Pass 101259 61.0 63.7 4.37

<+/-15%

Pass 100740 60.0 60.8 1.36

<+/-15%

Pass 101271 61.0 63.8 4.63

<+/-15%

Pass 100759 60.0 61.8 3.03

<+/-15%

Pass Average Bias (B) 4.17 Average Bias (B) 2.20 Standard Deviation (S) 1.75 Standard Deviation (S) 1.56 Measure Performance lBl+S 5.92

<15%

Pass Measure Performance lBl+S 3.76

<15%

Pass Section 5 - Page 11

Section 6 - Page 1

6.0 REFERENCES

6.1 Catawba Selected License Commitment Report 6.2 Catawba Technical Specifications 6.3 Catawba Updated Final Safety Analysis Review 6.4 Catawba Offsite Dose Calculation Manual 6.5 Catawba Annual Environmental Operating Report 1985 - 2005 6.6 Catawba Annual Effluent Report 1985 - 2006 6.7 Probability and Statistics in Engineering and Management Science, Hines and Montgomery, 1969, pages 287-293.

6.8 Practical Statistics for the Physical Sciences, Havilcek and Crain, 1988, pages 83-93.

6.9 Nuclear Regulatory Commission Regulatory Guide 1.109, Calculation of Annual Doses to Man from Routine Releases of Reactor Effluents for the Purposes of Evaluating Compliance with 10CFR50, Appendix I.

6.10 EnRad Laboratories Operating Procedures 6.11 RETDAS, Radiological Effluent Tracking and Dose Assessment Software, Canberra Version 3.5.1, DPC Revision #4.0 6.12 NRC Integrated Inspection Report 05-04 6.13 Duke Energy Corporation EnRad Laboratory Charcoal Cartridge Study, performed 2001

Appendix A - Page 1 APPENDIX A ENVIRONMENTAL SAMPLING ANALYSIS PROCEDURES

Appendix A - Page 2 APPENDIX A ENVIRONMENTAL SAMPLING AND ANALYSIS PROCEDURES Adherence to established procedures for sampling and analysis of all environmental media at Catawba Nuclear Station was required to ensure compliance with Station Selected Licensee Commitments. Analytical procedures were employed to ensure that Selected Licensee Commitments detection capabilities were achieved.

Environmental sampling and analyses were performed by EnRad Laboratories, Dosimetry and Records, Fisheries and Aquatic Ecology.

This appendix describes the environmental sampling frequencies and analysis procedures by media type.

I. CHANGE OF SAMPLING PROCEDURES No changes were made to the sampling procedures during 2006.

II. DESCRIPTION OF ANALYSIS PROCEDURES Gamma spectroscopy analyses are performed using high purity germanium gamma detectors and Canberra analytical software. Designated sample volumes are transferred to appropriate counting geometries and analyzed by gamma spectroscopy. Perishable samples such as fish and broadleaf vegetation are ground to achieve a homogeneous mixture. Soils and sediments are dried, sifted to remove foreign objects (rocks, clams, glass, etc.) then transferred to appropriate counting geometry.

Low-level iodine analyses are performed by passing a designated sample aliquot through a pre-weighed amount of ion exchange resin to remove and concentrate any iodine in the aqueous sample (milk). The resin is then dried, mixed thoroughly, and a net resin weight determined before being transferred to appropriate counting geometry and analyzed by gamma spectroscopy.

Tritium analyses are performed quarterly by using low-level environmental liquid scintillation analysis technique on a Packard 2550 liquid scintillation system or Perkin-Elmer 2900TR liquid scintillation system. Tritium samples are distilled and batch processed with a tritium spike and blank to verify instrument performance and sample preparation technique are acceptable.

Appendix A - Page 3 Gross beta analysis is performed by concentrating a designated aliquot of sample precipitate and analyzing by Tennelec XLB Series 5 gas-flow proportional counters.

Samples are batch processed with a blank to ensure sample contamination has not occurred.

III. CHANGE OF ANALYSIS PROCEDURES A methodology based on nuclide abundance was implemented for determining Mn-54 activity in the presence of naturally occurring Ac-228 interference in certain media types. The method is described in PIP G-06-00040.

IV. SAMPLING AND ANALYSIS PROCEDURES A.1 AIRBORNE PARTICULATE AND RADIOIODINE Airborne particulate and radioiodine samples at each of five locations were composited continuously by means of continuous air samplers. Air particulates were collected on a particulate filter and radioiodines were collected in a charcoal cartridge positioned behind the filter in the sampler. The samplers are designed to operate at a constant flow rate (in order to compensate for any filter loading) and are set to sample approximately 2 cubic feet per minute. Filters and cartridges were collected weekly. A separate weekly gamma analysis was performed on each charcoal cartridge and air particulate. A weekly gross beta analysis was performed on each filter. The continuous composite samples were collected from the locations listed below.

Location 200

=

Site Boundary (0.63 mi. NNE)

Location 201

=

Site Boundary (0.53 mi. NE)

Location 205

=

Site Boundary (0.23 mi. SW)

Location 212

=

Tega Cay (3.32 mi. E)

Location 258

=

Fairhope Road (9.84 mi. W)

A.2 DRINKING WATER Monthly composite drinking water samples were collected at each of two locations. A gross beta and gamma analysis was performed on monthly composites. Tritium analysis was performed on the quarterly composites. The composites were collected monthly from the locations listed below.

Location 214 = Rock Hill Water Supply (7.30 mi. SSE)

Location 218 = Belmont Water Supply (13.5 mi. NNE)

Appendix A - Page 4 A.3 SURFACE WATER Monthly composite samples were collected at each of three locations. A gamma analysis was performed on the monthly composites. Tritium analysis was performed on the quarterly composites. The composites were collected monthly from the locations listed below.

Location 208

=

Discharge Canal (0.45 mi. S)

Location 211

=

Wylie Dam (4.06 mi. ESE)

Location 215

=

River Pointe - Hwy 49 (4.21 mi. NNE)

A.4 GROUND WATER Grab samples were collected quarterly from residential wells at each of two locations. A gamma analysis and tritium analysis were performed on each sample. The samples were collected from the locations listed below.

Location 252

=

Residence (0.64 mi. SW)

Location 254

=

Residence (0.82 mi. N)

A.5 MILK Biweekly grab samples were collected at one location. A gamma and low-level Iodine-131 analysis was performed on each sample. The biweekly grab samples were collected from the location listed below.

Location 221

=

Dairy (14.5 mi. NW)

A.6 BROADLEAF VEGETATION Monthly samples were collected at each of five locations. A gamma analysis was performed on each sample. The samples were collected from the locations listed below.

Location 200

=

Site Boundary (0.63 mi. NNE)

Location 201

=

Site Boundary (0.53 mi. NE)

Location 222

=

Site Boundary (0.70 mi. N)

Location 226

=

Site Boundary (0.48 mi. S)

Location 258

=

Fairhope Road (9.84 mi. W)

Appendix A - Page 5 A.7 FOOD PRODUCTS Monthly samples were collected when available during the harvest season at one location. A gamma analysis was performed on each sample. The samples were collected from the location listed below.

Location 253

=

Irrigated Gardens (1.90 mi. SSE)

A.8 FISH Semiannual samples were collected at each of two locations. A gamma analysis was performed on the edible portions of each sample. Boney fish (i.e. Sunfish) were prepared whole minus the head and tail portions. The samples were collected from the locations listed below.

Location 208

=

Discharge Canal (0.45 mi. S)

Location 216

=

Hwy 49 Bridge (4.19 mi. NNE)

A.9 SHORELINE SEDIMENT Semiannual samples were collected at each of three locations. A gamma analysis was performed on each sample following the drying and removal of rocks and clams. The samples were collected from the locations listed below.

Location 208

=

Discharge Canal (0.45 mi. S)

Location 210

=

Ebenezer Access (2.31 mi. SE)

Location 215

=

River Pointe - Hwy 49 (4.21 mi. NNE)

A.10 DIRECT GAMMA RADIATION (TLD)

Thermoluminescent dosimeters (TLD) were collected quarterly at forty-one locations. A gamma exposure rate was determined for each TLD. TLD locations are listed in Table 2.1-B. The TLDs were placed as indicated below.

An inner ring of 16 TLDs, one in each meteorological sector in the general area of the site boundary.

An outer ring of 16 TLDs, one in each meteorological sector in the 6 to 8 kilometer range.

The remaining TLDs were placed in special interest areas such as population centers, residential areas, schools, and at three control locations.

Appendix A - Page 6 A.11 ANNUAL LAND USE CENSUS An Annual Land Use Census was conducted to identify within a distance of 8 kilometers (5.0 miles) from the station, the nearest location from the site boundary in each of the sixteen meteorological sectors, the following:

The Nearest Residence The Nearest Garden greater than 50 square meters or 500 square feet The Nearest Milk-giving Animal (cow, goat, etc.)

The census was conducted during the growing season on 7/17 and 7/18/2006.

Results are shown in Table 3.11. No changes were made to the sampling procedures during 2006 as a result of the 2006 census.

V.

GLOBAL POSITIONING SYSTEM (GPS) ANALYSIS The Catawba site centerline used for GPS measurements was referenced from the Catawba Nuclear Station Updated Final Safety Analysis Report (UFSAR), section 2.1.1.1, Specification of Location. Waypoint coordinates used for CNS GPS measurements were latitude 35°-3'-5"N and longitude 81°-4'-10"W. Maps and tables were generated using North American Datum (NAD) 27. Data normally reflect accuracy to within 2 to 5 meters from point of measurement. All GPS field measurements were taken as close as possible to the item of interest. Distances for the locations are displayed using three significant figures.

Appendix B - Page 1 APPENDIX B RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM

SUMMARY

OF RESULTS 2006

Environmental Radiological Monitoring Program Summary Facility: Catawba Nuclear Station Docket No. 50-413,414 Location: York County, South Carolina Report Period: 01-JAN-2006 to 31-DEC-2006 Medium or Pathway Sampled Type and Total Number of Lower Limit of Detection All Indicator Locations Location with Highest Annual Mean Name, Distance, Direction Control Location No. of Non-Routine Report Meas.

Unit of Measurement Analyses Performed (LLD)

Mean (Fraction)

Range Location Code Mean (Fraction)

Range Mean (Fraction)

Range Air Particulate 258 (pCi/m3)

(9.84 mi W)

BETA 260 1.00E-02 1.65E-2 (208/208) 200 1.74E-2 (52/52) 1.74E-2 (52/52) 0 3.27E 2.73E-2 (0.63 mi NNE) 7.68E 2.73E-2 6.67E 2.56E-2 CS-134 260 5.00E-02 0.00 (0/208) 0.00 (0/52) 0.00 (0/52) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 CS-137 260 6.00E-02 0.00 (0/208) 0.00 (0/52) 0.00 (0/52) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 I-131 260 7.00E-02 0.00 (0/208) 0.00 (0/52) 0.00 (0/52) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 Mean and range based upon detectable measurements only Fraction of detectable measurements at specified locations is indicated in parentheses, (Fraction)

Zero range indicates no detectable activity measurements Report Generated @ 4/26/2007 16:02 Appendix B - Page 2

Environmental Radiological Monitoring Program Summary Facility: Catawba Nuclear Station Docket No.

50-413,414 Location: York County, South Carolina Report Period: 01-JAN-2006 to 31-DEC-2006 Medium or Pathway Sampled Type and Total Number of Lower Limit of Detection All Indicator Locations Location with Highest Annual Mean Name, Distance, Direction Control Location No. of Non-Routine Report Meas.

Unit of Measurement Analyses Performed (LLD)

Mean (Fraction)

Range Location Code Mean (Fraction)

Range Mean (Fraction)

Range Air Radioiodine 258 (pCi/m3)

(9.84 mi W)

CS-134 260 5.00E-02 0.00 (0/208) 0.00 (0/52) 0.00 (0/52) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 CS-137 260 6.00E-02 9.87E-3 (1/208) 200 9.87E-3 (1/52) 0.00 (0/52) 0 9.87E 9.87E-3 (0.63 mi NNE) 9.87E 9.87E-3 0.00 - 0.00 I-131 260 7.00E-02 0.00 (0/208) 0.00 (0/52) 0.00 (0/52) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 Mean and range based upon detectable measurements only Fraction of detectable measurements at specified locations is indicated in parentheses, (Fraction)

Zero range indicates no detectable activity measurements Report Generated @ 4/26/2007 16:02 Appendix B - Page 3

Environmental Radiological Monitoring Program Summary Facility: Catawba Nuclear Station Docket No.

50-413,414 Location: York County, South Carolina Report Period: 01-JAN-2006 to 31-DEC-2006 Medium or Pathway Sampled Type and Total Number of Lower Limit of Detection All Indicator Locations Location with Highest Annual Mean Name, Distance, Direction Control Location No. of Non-Routine Report Meas.

Unit of Measurement Analyses Performed (LLD)

Mean (Fraction)

Range Location Code Mean (Fraction)

Range Mean (Fraction)

Range Drinking Water 218 (pCi/liter)

(13.5 mi NNE)

BALA-140 26 15 0.00 (0/13) 0.00 (0/14) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 BETA 26 4

2.30 (13/13) 214 2.30 (13/13) 2.17 (13/13) 0 1.36 - 3.51 (7.30 mi SSE) 1.36 - 3.51 1.31 - 3.77 CO-58 26 15 0.00 (0/13) 0.00 (0/14) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 CO-60 26 15 0.00 (0/13) 0.00 (0/14) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 CS-134 26 15 0.00 (0/13) 0.00 (0/14) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 CS-137 26 18 0.00 (0/13) 0.00 (0/14) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 FE-59 26 30 0.00 (0/13) 0.00 (0/14) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 H-3 8

2000 1598 (4/4) 214 1598 (4/4) 770 (4/4) 0 1000 - 2200 (7.30 mi SSE) 1000 - 2200 582 - 1170 I-131 26 15 0.00 (0/13) 0.00 (0/14) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 MN-54 26 15 0.00 (0/13) 0.00 (0/14) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 NB-95 26 15 0.00 (0/13) 0.00 (0/14) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 ZN-65 26 30 0.00 (0/13) 0.00 (0/14) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 ZR-95 26 15 0.00 (0/13) 0.00 (0/14) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 Mean and range based upon detectable measurements only Fraction of detectable measurements at specified locations is indicated in parentheses, (Fraction)

Zero range indicates no detectable activity measurements Report Generated @ 4/26/2007 16:03 Appendix B - Page 4

Environmental Radiological Monitoring Program Summary Facility: Catawba Nuclear Station Docket No.

50-413,414 Location: York County, South Carolina Report Period: 01-JAN-2006 to 31-DEC-2006 Medium or Pathway Sampled Type and Total Number of Lower Limit of Detection All Indicator Locations Location with Highest Annual Mean Name, Distance, Direction Control Location No. of Non-Routine Report Meas.

Unit of Measurement Analyses Performed (LLD)

Mean (Fraction)

Range Location Code Mean (Fraction)

Range Mean (Fraction)

Range Surface Water 215 (pCi/liter)

(4.21 mi NNE)

BALA-140 39 15 0.00 (0/26) 0.00 (0/13) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 CO-58 39 15 0.00 (0/26) 0.00 (0/13) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 CO-60 39 15 0.00 (0/26) 0.00 (0/13) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 CS-134 39 15 0.00 (0/26) 0.00 (0/13) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 CS-137 39 18 0.00 (0/26) 0.00 (0/13) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 FE-59 39 30 0.00 (0/26) 0.00 (0/13) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 H-3 12 2000 8998 (8/8) 208 16700 (4/4) 583 (4/4) 0 681 - 18000 (0.45 mi S) 15400 - 18000 442 - 827 I-131 39 15 0.00 (0/26) 0.00 (0/13) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 MN-54 39 15 0.00 (0/26) 0.00 (0/13) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 NB-95 39 15 0.00 (0/26) 0.00 (0/13) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 ZN-65 39 30 0.00 (0/26) 0.00 (0/13) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 ZR-95 39 15 0.00 (0/26) 0.00 (0/13) 0.00 (0/13) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 Mean and range based upon detectable measurements only Fraction of detectable measurements at specified locations is indicated in parentheses, (Fraction)

Zero range indicates no detectable activity measurements Report Generated @ 4/26/2007 16:03 Appendix B - Page 5

Environmental Radiological Monitoring Program Summary Facility: Catawba Nuclear Station Docket No.

50-413,414 Location: York County, South Carolina Report Period: 01-JAN-2006 to 31-DEC-2006 Medium or Pathway Sampled Type and Total Number of Lower Limit of Detection All Indicator Locations Location with Highest Annual Mean Name, Distance, Direction Control Location No. of Non-Routine Report Meas.

Unit of Measurement Analyses Performed (LLD)

Mean (Fraction)

Range Location Code Mean (Fraction)

Range Mean (Fraction)

Range Ground Water NO CONTROL (pCi/liter)

LOCATION BALA-140 8

15 0.00 (0/8) 0.00 (0/8) 0.00 (0/0) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 CO-58 8

15 0.00 (0/8) 0.00 (0/8) 0.00 (0/0) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 CO-60 8

15 0.00 (0/8) 0.00 (0/8) 0.00 (0/0) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 CS-134 8

15 0.00 (0/8) 0.00 (0/8) 0.00 (0/0) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 CS-137 8

18 0.00 (0/8) 0.00 (0/8) 0.00 (0/0) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 FE-59 8

30 0.00 (0/8) 0.00 (0/8) 0.00 (0/0) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 H-3 8

2000 0.00 (0/8) 0.00 (0/8) 0.00 (0/0) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 I-131 8

15 0.00 (0/8) 0.00 (0/8) 0.00 (0/0) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 MN-54 8

15 0.00 (0/8) 0.00 (0/8) 0.00 (0/0) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 NB-95 8

15 0.00 (0/8) 0.00 (0/8) 0.00 (0/0) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 ZN-65 8

30 0.00 (0/8) 0.00 (0/8) 0.00 (0/0) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 ZR-95 8

15 0.00 (0/8) 0.00 (0/8) 0.00 (0/0) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 Mean and range based upon detectable measurements only Fraction of detectable measurements at specified locations is indicated in parentheses, (Fraction)

Zero range indicates no detectable activity measurements Report Generated @ 4/26/2007 16:04 Appendix B - Page 6

Environmental Radiological Monitoring Program Summary Facility: Catawba Nuclear Station Docket No.

50-413,414 Location: York County, South Carolina Report Period: 01-JAN-2006 to 31-DEC-2006 Medium or Pathway Sampled Type and Total Number of Lower Limit of Detection All Indicator Locations Location with Highest Annual Mean Name, Distance, Direction Control Location No. of Non-Routine Report Meas.

Unit of Measurement Analyses Performed (LLD)

Mean (Fraction)

Range Location Code Mean (Fraction)

Range Mean (Fraction)

Range Milk NO INDICATOR 221 (pCi/liter)

LOCATION (14.5 mi NW)

BALA-140 26 15 0.00 (0/0) 0.00 (0/0) 0.00 (0/26) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 CS-134 26 15 0.00 (0/0) 0.00 (0/0) 0.00 (0/26) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 CS-137 26 18 0.00 (0/0) 0.00 (0/0) 0.00 (0/26) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 I-131 26 15 0.00 (0/0) 0.00 (0/0) 0.00 (0/26) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 LLI-131 26 1

0.00 (0/0) 0.00 (0/0) 0.00 (0/26) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 Mean and range based upon detectable measurements only Fraction of detectable measurements at specified locations is indicated in parentheses, (Fraction)

Zero range indicates no detectable activity measurements Report Generated @ 4/26/2007 16:05 Appendix B - Page 7

Environmental Radiological Monitoring Program Summary Facility: Catawba Nuclear Station Docket No.

50-413,414 Location: York County, South Carolina Report Period: 01-JAN-2006 to 31-DEC-2006 Medium or Pathway Sampled Type and Total Number of Lower Limit of Detection All Indicator Locations Location with Highest Annual Mean Name, Distance, Direction Control Location No. of Non-Routine Report Meas.

Unit of Measurement Analyses Performed (LLD)

Mean (Fraction)

Range Location Code Mean (Fraction)

Range Mean (Fraction)

Range Broadleaf 258 Vegetation (9.84 mi W)

(pCi/kg-wet)

CS-134 60 60 0.00 (0/48) 0.00 (0/12) 0.00 (0/12) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 CS-137 60 80 57.9 (9/48) 201 57.9 (9/12) 0.00 (0/12) 0 24.6 - 125 (0.53 mi NE) 24.6 - 125 0.00 - 0.00 I-131 60 60 0.00 (0/48) 0.00 (0/12) 0.00 (0/12) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 Mean and range based upon detectable measurements only Fraction of detectable measurements at specified locations is indicated in parentheses, (Fraction)

Zero range indicates no detectable activity measurements Report Generated @ 4/26/2007 16:05 Appendix B - Page 8

Environmental Radiological Monitoring Program Summary Facility: Catawba Nuclear Station Docket No.

50-413,414 Location: York County, South Carolina Report Period: 01-JAN-2006 to 31-DEC-2006 Medium or Pathway Sampled Type and Total Number of Lower Limit of Detection All Indicator Locations Location with Highest Annual Mean Name, Distance, Direction Control Location No. of Non-Routine Report Meas.

Unit of Measurement Analyses Performed (LLD)

Mean (Fraction)

Range Location Code Mean (Fraction)

Range Mean (Fraction)

Range Food Products NO CONTROL (pCi/kg-wet)

LOCATION CS-134 4

60 0.00 (0/4) 0.00 (0/4) 0.00 (0/0) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 CS-137 4

80 0.00 (0/4) 0.00 (0/4) 0.00 (0/0) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 I-131 4

60 0.00 (0/4) 0.00 (0/4) 0.00 (0/0) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 Mean and range based upon detectable measurements only Fraction of detectable measurements at specified locations is indicated in parentheses, (Fraction)

Zero range indicates no detectable activity measurements Report Generated @ 4/26/2007 16:06 Appendix B - Page 9

Environmental Radiological Monitoring Program Summary Facility: Catawba Nuclear Station Docket No.

50-413,414 Location: York County, South Carolina Report Period: 01-JAN-2006 to 31-DEC-2006 Medium or Pathway Sampled Type and Total Number of Lower Limit of Detection All Indicator Locations Location with Highest Annual Mean Name, Distance, Direction Control Location No. of Non-Routine Report Meas.

Unit of Measurement Analyses Performed (LLD)

Mean (Fraction)

Range Location Code Mean (Fraction)

Range Mean (Fraction)

Range Fish 216 (pCi/kg-wet)

(4.19 mi NNE)

CO-58 12 130 0.00 (0/6) 0.00 (0/6) 0.00 (0/6) 0 0.00 - 0.00 0.00 (0/6) 0.00 - 0.00 CO-60 12 130 0.00 (0/6) 0.00 - 0.00 0.00 (0/6) 0 0.00 - 0.00 0.00 (0/6) 0.00 - 0.00 CS-134 12 130 0.00 (0/6) 0.00 (0/6) 0.00 (0/6) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 CS-137 12 150 14.4 (1/6) 208 14.4 (1/6) 0.00 (0/6) 0 14.4 - 14.4 (0.45 mi S) 14.4 - 14.4 0.00 - 0.00 FE-59 12 260 0.00 (0/6) 0.00 (0/6) 0.00 (0/6) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 MN-54 12 130 0.00 (0/6) 0.00 (0/6) 0.00 (0/6) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 ZN-65 12 260 0.00 (0/6) 0.00 (0/6) 0.00 (0/6) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 Mean and range based upon detectable measurements only Fraction of detectable measurements at specified locations is indicated in parentheses, (Fraction)

Zero range indicates no detectable activity measurements Report Generated @ 4/26/2007 16:06 Appendix B - Page 10

Environmental Radiological Monitoring Program Summary Facility: Catawba Nuclear Station Docket No.

50-413,414 Location: York County, South Carolina Report Period: 01-JAN-2006 to 31-DEC-2006 Medium or Pathway Sampled Type and Total Number of Lower Limit of Detection All Indicator Locations Location with Highest Annual Mean Name, Distance, Direction Control Location No. of Non-Routine Report Meas.

Unit of Measurement Analyses Performed (LLD)

Mean (Fraction)

Range Location Code Mean (Fraction)

Range Mean (Fraction)

Range Shoreline 215 Sediment (4.21 mi NNE)

(pCi/kg-dry)

MN-54 6

0 0.00 (0/4) 0.00 (0/2) 0.00 (0/2) 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 CO-58 6

0 54.0 (1/4) 208-1S 54.0 (1/2) 0.00 (0/2) 0 54.0 - 54.0 (0.45 mi S) 54.0 - 54.0 0.00 - 0.00 CO-60 6

0 111 (1/4) 208-1S 111 (1/2) 0.00 (0/2) 0 111 - 111 (0.45 mi S) 111 - 111 0.00 - 0.00 CS-134 6

150 0.00 (0/4) 0.00 (0/2) 0.00 (0/2) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 CS-137 6

180 0.00 (0/4) 0.00 (0/2) 0.00 (0/2) 0 0.00 - 0.00 0.00 - 0.00 0.00 - 0.00 Mean and range based upon detectable measurements only Fraction of detectable measurements at specified locations is indicated in parentheses, (Fraction)

Zero range indicates no detectable activity measurements If LLD is equal to 0.00, then the LLD is not required by Selected Licensee Commitments Report Generated @ 4/26/2007 16:07 Appendix B - Page 11

Environmental Radiological Monitoring Program Summary Facility: Catawba Nuclear Station Docket No.

50-413,414 Location: York County, South Carolina Report Period: 01-JAN-2006 to 31-DEC-2006 Medium or Pathway Sampled Type and Total Number of Lower Limit of Detection All Indicator Locations Location with Highest Annual Mean Name, Distance, Direction Control Location No. of Non-Routine Report Meas.

Unit of Measurement Analyses Performed (LLD)

Mean (Fraction)

Range Location Code Mean (Fraction)

Range Mean (Fraction)

Range Direct Radiation 217 (10.3 mi SSE)

TLD 247 (7.33 mi ESE)

(mR/standard quarter) 251 (9.72 mi WNW) 158 0.00E+00 18.6 (147/147) 235 26.4 (4/4) 14.3 (11/11) 0 9.90 - 30.9 (4.07 mi ESE) 23.4 - 30.9 10.0 - 19.3 Mean and range based upon detectable measurements only Fraction of detectable measurements at specified locations is indicated in parentheses, (Fraction)

Zero range indicates no detectable activity measurements Report Generated @ 4/26/2007 16:07 Appendix B - Page 12

Appendix C - Page 1 APPENDIX C SAMPLING DEVIATIONS UNAVAILABLE ANALYSES

Appendix C - Page 2 APPENDIX C CATAWBA NUCLEAR STATION SAMPLING DEVIATIONS & UNAVAILABLE ANALYSES DEVIATION & UNAVAILABLE REASON CODES BF Blown Fuse PO Power Outage FZ Sample Frozen PS Pump out of service / Undergoing Repair IW Inclement Weather SL Sample Loss/Lost due to Lab Accident LC Line Clog to Sampler SM Motor / Rotor Seized OT Other TF Torn Filter PI Power Interrupt VN Vandalism PM Preventive Maintenance CN Construction C.1 SAMPLING DEVIATIONS Air Particulate and Air Radioiodines Location Scheduled Collection Dates Actual Collection Dates Reason Code Corrective Action 205*

8/22-8/29/2006 8/22-8/24/2006 BF A blown fuse in air sampler was found at time of collection. Fuse was replaced and normal sampling resumed.

212 9/26-10/3/2006 9/26-10/3/2006 PI Deviation due to planned power interruption. Tega Cay Retail performed work on the AC Load Center that supplies power to site. Power was interrupted to the site at 9/28/2006 12:30. The duration of the interruption was 2.20 hours2.314815e-4 days <br />0.00556 hours <br />3.306878e-5 weeks <br />7.61e-6 months <br />. Power was restored 9/28/2006 14:42. Samplers were verified operational following power restoration and normal sampling resumed.

205*

10/17-10/24/2006 10/17-10/18/2006 BF A blown fuse in air sampler was found at time of collection. Fuse was replaced and normal sampling resumed.

205*

10/31-11/7/2006 10/31-11/6/2006 BF A blown fuse in air sampler was found at time of collection. Fuse was replaced and normal sampling resumed.

205*

12/5-12/12/2006 12/5-12/11/2006 BF A blown fuse in air sampler was found at time of collection. Fuse was replaced and normal sampling resumed.

  • Location 205 is not configured for redundant operation of air sampling equipment. Historically, this location has not been problematic for this type of deviation. The last occurrence of a blown fuse to an air sampler at this location prior to 2006 was for scheduled monitoring period of 9/23-9/30/1998. Moisture interference with the line conditioner at this location is the suspected cause for the repeated occurrence of blown fuses.

Appendix C - Page 3 Drinking Water Location Scheduled Collection Dates Actual Collection Dates Reason Code Corrective Action 214 1/17-2/14/2006 1/17-2/13/2006 PI Power to sampling equipment was interrupted. The water treatment plant manager indicated the power was interrupted at approximately 2/13/2006 09:00 for sandblasting of the interior walls where sampling equipment is located.

Construction work and its potential impact on sampling equipment at this location is described in PIP G-05-00200.

218 4/11-5/9/2006 5/9/2006 LC Line clog to sampling equipment interrupted water flow. Work request 65283 and PIP C-06-03581 initiated. A grab sample was taken on 5/9/2006.

Normal sampling resumed 5/9/2006 16:00.

214 5/9-6/6/2006 6/6/2006 PI Power to sampling equipment was interrupted due to construction.

Insufficient composite volume was available so a grab sample was taken.

Construction work and its potential impact on sampling equipment at this location is described in PIP G-05-00200. Equipment was verified operational and normal sampling resumed.

C.2 UNAVAILABLE ANALYSES TLD Location Scheduled Collection Dates Reason Code Corrective Action 234*

12/14-3/15/2006 VN TLD missing. 2nd quarter 2006 TLD placed in field.

225 3/15-6/14/2006 VN TLD missing. 3rd quarter 2006 TLD placed in field.

237 3/15-6/14/2006 CN TLD missing. 3rd quarter 2006 TLD placed in field.

240 6/14-9/13/2006 VN TLD missing. 4th quarter 2006 TLD placed in field.

246 9/13-12/13/2006 VN TLD missing. 1st quarter 2007 TLD placed in field.

251 9/13-12/13/2006 VN TLD missing. 1st quarter 2007 TLD placed in field.

  • TLD 234 is located in the E sector at 4.50 miles. The TLD is currently placed near the corner of a commercial bank parking lot which is heavily traveled by the general public. This location has undergone tremendous commercial development recently. A study TLD was placed in the same sector at 4.48 miles (GPS handheld measurement made on 3/15/2006) on a South Carolina highway road sign indicating "Beck Meacham Richardson Highway" which is on Gold Hill Road on the other side of the commercial bank parking lot. "Study TLD" placed as part of ASSESSMENT NO.: GO-06-62(RP)(REMP)(CNS) & PIP No: G-06-00151. Study TLD was added to program as a secondary TLD location for site 234.

Appendix D - Page 1 APPENDIX D ANALYTICAL DEVIATIONS No Analytical deviations were incurred for the 2006 Radiological Environmental Monitoring Program

Appendix E - Page 1 APPENDIX E RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM RESULTS This appendix includes all of the sample analysis reports generated from each sample medium for 2006. Appendix E is located separately from this report and is permanently archived at the Duke Energy Corporation Environmental Center radiological environmental master file, located at the McGuire Nuclear Station Site in Huntersville, North Carolina.