Technical Specification, Core Spray Instrumentation
ML070380493
Person / Time
Site: Nine Mile Point 
(DPR-063)
Issue date: 01/31/2007
From:
NRC/NRR/ADRO/DORL/LPLI-1
To:
References
TAC MC9626
Download: ML070380493 (2)


Text

(3)

Pursuant to the Act and 10 CFR Parts 30, 40, and 70 to receive, possess and use at any time any byproduct, source and special nuclear material as sealed neutron sources for reactor startup, sealed sources for reactor instrumentation and radiation monitoring equipment calibration, and as fission detectors in amounts as required; (4)

Pursuant to the Act and 10 CFR Parts 30, 40 and 70, to receive, possess and use in amounts as required any byproduct, source or special nuclear material without restriction to chemical or physical form, for sample analysis or instrument and equipment calibration or associated with radioactive apparatus or components.

(5)

Pursuant to the Act and 10 CFR Parts 30 and 70, to possess, but not separate, such byproduct and special nuclear materials as may be produced by the operation of the facility.

C.

This renewed operating license shall be deemed to contain and is subject to the conditions specified in the following Commission regulations in 10 CFR Chapter I:

Part 20, Section 30.34 of Part 30; Section 40.41 of Part 40; Section 50.54 and 50.59 of Part 50; and Section 70.32 of Part 70. This renewed license is subject to all applicable provisions of the Act and to the rules, regulations, and orders of the Commission now or hereafter in effect and is also subject to the additional conditions specified or incorporated below:

(1)

Maximum Power Level The licensee is authorized to operate the facility at steady state reactor core power levels not in excess of 1850 megawatts (thermal).

(2)

Technical Specifications The Technical Specifications contained in Appendix A, which is attached hereto, as revised through Amendment No. 1o2 is hereby incorporated into this license. Nine Mile Point Nuclear Station, LLC shall operate the facility in accordance with the Technical Specifications.

(3)

The licensee shall submit an application for license amendment, including supporting analyses and evaluations by December 18, 1998. This amendment application shall contain the proposed methods for compliance with GDC 19 dose guidelines under accident conditions based upon system design.and without reliance upon the use of potassium iodide.

F'eneovved License Nc~. DPR-630

LIMITING CONDITION FOR OPERATION If Specifications a, b and c are not met, a normal orderly,s1'hutdown shall be initiated within one-hour and the reactor shall be in the cold shuldown condition within ten hours.

e.

During reactor operation, except during core spray system surveillance testing, core spray isolation valves 40-02 and 40-12 shall be in the open position and the associated valve motor starler circuit breakers for these valves shall be locked in the off position. In addition, redundant valve position indication shall be available in the (onterol

0oomI,

\\VIie iever irradiated fuel is in the reactor vessel and the reactor coolant temperature is less than or equal to 21:2-F, two core spray subsystems shall be operable except as specified in g and h below.

If one of the above required subsystems becomes inoperable, restore at least two subsystems to an operable status within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> cr suspenrd all operations that have a potential for draining the reactor vessel.

SURVEILLANCE REQUIREMENT 0

d.

(Deleted)

e.

Surveillance with Inoperable Components When a component becomes inoperable its redundant component or system shall be verified to be operable immediately and daily thereafter.

f.

With a core spray subsystem suction from the CST, CST level shall be checked once per day.

g.

At least once per month when the reactor coolant temperature is greater than 2121F, verify that the piping system between valves 40-03, 13 and 40-01, 09, 10, 11 is filled with water.

AM I-N D MVI N-NO..14;),. 192 0