License Amendment Request: Proposed Changes to Technical Specification 4.1.4 Regarding Core Spray Instrumentation - Supplemental Information
ML063070132
Person / Time
Site: Nine Mile Point Constellation icon.png
Issue date: 10/25/2006
From: O'Connor T
Constellation Energy Group
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
TAC MC9626
Download: ML063070132 (3)


Text

Timothy J. O'Connor P.O. Box 63 Vice President Lycoming, New York 13093 315.349.1392 315.349.1321 Fax 0Constellation Energy, Nine Mile Point Nuclear Station October 25, 2006 U. S. Nuclear Regulatory Commission Washington, DC 20555-0001 ATTENTION: Document Control Desk

SUBJECT:

Nine Mile Point Nuclear Station Unit No. 1; Docket No. 50-220 License Amendment Request: Proposed Changes to Technical Specification 4.1.4 Regarding Core Spray Instrumentation -

Supplemental Information (TAC No. MC9626)

Nine Mile Point Nuclear Station, LLC (NMPNS) hereby transmits supplemental information requested by the NRC in support of a previously submitted application for amendment to Nine Mile Point Unit 1 (NMP1) Operating License DPR-63. The initial application, dated December 16, 2005, proposed a revision to Technical Specification (TS) Surveillance Requirement (SR) 4.1.4d by relocating the periodic checking, calibration, and testing requirements for the core spray header differential pressure (AP) instrumentation to licensee-controlled documents that are controlled in accordance with the provisions of 10 CFR 50.59. In response to a NRC staff verbal request, as discussed in a telephone conference call on October 19, 2006, NMPNS hereby supplements the December 16, 2005 submittal by clarifying that the requirements currently contained in SR 4.1.4d will be relocated to the NMP1 Updated Final Safety Analysis Report (UFSAR). This revised regulatory commitment is shown in Attachment (1).

This supplemental information does not affect the No Significant Hazards Consideration Analysis provided in the NMPNS letter dated December 16, 2005. Pursuant to 10 CFR 50.91(b)(1), NMPNS has provided a copy of this supplemental information to the appropriate state representative.

Should you have any questions regarding the information in this submittal, please contact M. H. Miller, Licensing Director, at (315) 349-1510.

Ve truly yo s, et IA

Document Control Desk October 25, 2006 Page 2 STATE OF NEW YORK TO WIT:

COUNTY OF OSWEGO I, Timothy J. O'Connor, being duly sworn, state that I am Vice President Nine Mile Point, and that I am duly authorized to execute and file this supplemental information on behalf of Nine Mile Point Nuclear Station, LLC. To the best of my knowledge and belief, the statements contained in this document are true and correct. To the extent that these statements are not based on my personal knowledge, they are based upon information provided by other Nine Mile Point employees and/or consultants Such information has been reviewed in accordance with company practice and I believe* to b li bl Subscribed and sworn before me, a Notary Public in and for the State of New York and County of Oswego, this 25 day of c 2006.

WITNESS my Hand and Notarial Seal: >4 Notary Public My Commission Expires: to/R./oc Date TJO/DEV/kms SANDRA A. OSWALD Notary Public, State of New York No. 01OS6032276 Attachments: (1) List of Regulatory Commitments Qualified in Oswego Co,....

cc: S. J. Collins, NRC T. G. Colburn, NRC Resident Inspector, NRC J. P. Spath, NYSERDA

ATTACHMENT (1)

LIST OF REGULATORY COMMITMENTS The following table identifies those actions committed to by Nine Mile Point Nuclear Station, LLC (NMPNS) in this document. This table supersedes the regulatory commitment table contained in Section 5.3 of Attachment I of NMPNS's letter dated December 16, 2005.

REGULATORY COMMITMENT DUE DATE/EVENT NMPNS will relocate the surveillance testing requirements for the core Within 60 days of TS spray header differential pressure (AP) instrumentation to the Nine Mile amendment issuance Point Unit 1 Updated Final Safety Analysis Report (UFSAR). Any (concurrent with changes to the requirements will be controlled in accordance with 10 CFR implementation of the 50.59. amendment).

Nine Mile Point Nuclear Station, LLC October 25, 2006