October 12, 2006 Mr. John T. Conway Site Vice President Monticello Nuclear Generating Plant Nuclear Management Company, LLC 2807 West County Road 75 Monticello, MN 55362-9637
SUBJECT:
MONTICELLO NUCLEAR GENERATING PLANT (MNGP) - CORRECTION OF AMENDMENT RE: IMPROVED TECHNICAL SPECIFICATIONS (TAC NO. MC7505)
Dear Mr. Conway:
On June 5, 2006, the Nuclear Regulatory Commission (NRC) issued Amendment No. 146 to Facility Operating License No. DPR-22 for MNGP. The amendment converted the Technical Specifications (TSs) from the previous custom format to the Improved Technical Specifications (ITSs) format.
Subsequent to issuance, the NRC staff noted that, due to an administrative error, the direction of the allowable value sign for Function 2.i (regarding recirculation pump differential pressure -
high) was inadvertently reversed in Table 3.3.5.1-1, Emergency Core Cooling System Instrumentation. The associated Bases (a licensee-controlled document) correctly reflects the previous requirement as specified in the custom TSs, stating that the differential pressure (dp) switches will trip when the dp across the pump is greater than a pre-determined value.
The NRC staff regrets any inconvenience these errors may have caused you.
Sincerely,
/RA/
Peter S. Tam, Senior Project Manager Plant Licensing Branch III-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-263
Enclosure:
TS Page 3.3.5.1-8 cc w/encl: See next page
Mr. John T. Conway October 12, 2006 Site Vice President Monticello Nuclear Generating Plant Nuclear Management Company, LLC 2807 West County Road 75 Monticello, MN 55362-9637
SUBJECT:
MONTICELLO NUCLEAR GENERATING PLANT (MNGP) - CORRECTION OF AMENDMENT RE: IMPROVED TECHNICAL SPECIFICATIONS (TAC NO. MC7505)
Dear Mr. Conway:
On June 5, 2006, the Nuclear Regulatory Commission (NRC) issued Amendment No. 146 to Facility Operating License No. DPR-22 for MNGP. The amendment converted the Technical Specifications (TSs) from the previous custom format to the Improved Technical Specifications (ITSs) format.
Subsequent to issuance, the NRC staff noted that, due to an administrative error, the direction of the allowable value sign for Function 2.i (regarding recirculation pump differential pressure -
high) was inadvertently reversed in Table 3.3.5.1-1, Emergency Core Cooling System Instrumentation. The associated Bases (a licensee-controlled document) correctly reflects the previous requirement as specified in the custom TSs, stating that the differential pressure (dp) switches will trip when the dp across the pump is greater than a pre-determined value.
The NRC staff regrets any inconvenience these errors may have caused you.
Sincerely,
/RA/
Peter S. Tam, Senior Project Manager Plant Licensing Branch III-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-263
Enclosure:
TS Page 3.3.5.1-8 cc w/encl: See next page DISTRIBUTION PUBLIC LPL3-1 r/f RidsNrrDorlLpl3-1 RidsNrrPMPTam RidsNrrLATHarris RidsOGCRp RidsAcrsAcnwMailCenter RidsNrrDirsltsb G. Hill, OIS RidsRgn3MailCenter RidsNrrDorlDpr Amendment Accession No.: ML062850028 TS: ML06292004 PKG: ML062920301 OFFICE LPL3-1/PM LPL3-1/LA LPL3-1/BC(A)
NAME PTam THarris Ptam for MMurphy DATE 10/6/06 10/12 /06 10/6/06 OFFICIAL RECORD COPY
Monticello Nuclear Generating Plant cc:
Jonathan Rogoff, Esquire Vice President, Counsel & Secretary Nuclear Management Company, LLC 700 First Street Hudson, WI 54016 U.S. Nuclear Regulatory Commission Resident Inspector's Office 2807 W. County Road 75 Monticello, MN 55362 Manager, Nuclear Safety Assessment Monticello Nuclear Generating Plant Nuclear Management Company, LLC 2807 West County Road 75 Monticello, MN 55362-9637 Commissioner Minnesota Pollution Control Agency 520 Lafayette Road St. Paul, MN 55155-4194 Regional Administrator, Region III U.S. Nuclear Regulatory Commission Suite 210 2443 Warrenville Road Lisle, IL 60532-4351 Commissioner Minnesota Department of Health 717 Delaware Street, S. E.
Minneapolis, MN 55440 Douglas M. Gruber, Auditor/Treasurer Wright County Government Center 10 NW Second Street Buffalo, MN 55313 Commissioner Minnesota Department of Commerce 85 7th Place East, Suite 500 St. Paul, MN 55101-2198 Manager - Environmental Protection Division Minnesota Attorney Generals Office 445 Minnesota St., Suite 900 St. Paul, MN 55101-2127 Michael B. Sellman President and Chief Executive Officer Nuclear Management Company, LLC 700 First Street Hudson, MI 54016 Nuclear Asset Manager Xcel Energy, Inc.
414 Nicollet Mall, R.S. 8 Minneapolis, MN 55401 November 2005