Tech Spec Pages for Amendment 264, Regarding Excess Flow Check Valve Surveillance Intervals (TS-438)
ML062840069
Person / Time
Site: Browns Ferry 
(DPR-033)
Issue date: 09/29/2006
From:
NRC/NRR/ADRO/DORL/LPLII-2
To:
Chernoff M, NRR/DORL, 415-4041
Shared Package
ML062830239 List:
References
TAC MC4659
Download: ML062840069 (2)


Text

(3)

Pursuant to the Act and 10 CFR Parts 30, 40, and 70, to receive, possess, and use at any time any byproduct, source, and special nuclear material as sealed neutron sources for reactor startup, sealed sources for reactor instrumentaton and radiation monitoring equipment calibration, and as fission detectors in amounts as required; (4)

Pursuant to the Act and 10 CFR Parts 30, 40, and 70, to receive, possess, and use in amounts as required any byproduct, source, or special nuclear material without restriction to chemical or physical form for sample analysis or equipment and instrument calibration or associated with radioactive apparatus or components;.

(5)

Pursuant to the Act and 10 CFR Parts 30 and 70, to possess but not separate, such byproduct and special nuclear materials as may be produced by the operation of the facility.

C.

This renewed operating license shall be deemed to contain and is subject to the conditions specified in the following Commission regulations in 10 CFR Chapter 1:

Part 20, Section 30.34 of Part 30, Section 40.41 of Part 40, Sections 50.54 and 50.59 of Part 50, and Section 70.32 of Part 70; is subject to all applicable provisions of the Act and to the rules, regulations,- and orders of the Commission now or hereafter in effect; and is subject to the additional conditions specified or incorporated below:

(1)

Maximum Power Level The licensee is authorized to operate the facility at steady state reactor core power levels not in excess of 3293 megawatts thermal.

(2)

Technical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No. 264, are hereby incorporated in the renewed operating license. The licensee shall operate the facility in accordance with the Technical Specifications.

For Surveillance Requirements (SRs) that are new in Amendment 234 to Facility Operating License DPR-33, the first performance is due at the end of the first surveillance interval that begins at implementation of the Amendment 234. For SRs that existed prior to Amendment 234, including SRs with modified acceptance criteria and SRs whose frequency of performance is being extended, the first performance is due at the end of the first surveillance interval that begins on the date the surveillance was last performed prior to implementation of -Amendment 234.

Renewed License No. DPR-33 Amendment No. 264

PCIVS 3.6.1.3 SURVEILLANCE REQUIREMENTS (continued)

SURVEILLANCE FREQUENCY S R 3.6.1.3.5 Verify the isolation time of each power In accordance operated, automatic POIV, except for MSIVs, with the Inservice is within limits.

Testing Program S R 3.6.1.3.6 Verify the isolation time of each MSIV is Ž:3 In accordance seconds and *ý 5 seconds.

with the Inservice Testing Program S R 3.6.1.3.7 Verify each automatic PCIV actuates to the 24 months isolation position on an actual or simulated isolation signal.

S R 3.6.1.3.8 Verify a representative sample of reactor 24 months instrumentation line EFCVs actuate to the isolation position on a simulated instrument line break signal.

SR 3.6.1.3.9 Remove and test the explosive squib from 24 months on a each shear isolation valve of the TIP System.

STAGGERED TEST BASIS S R 3.6.1.3. 10 Verify leakage rate through each MSIV is In accordance

  • - 100 scfh and that the combined leakage with the Primary rate for all four main steam lines is *5 150 scfh Containment when tested at Ž:25 psig.

Lea 'kage Rate Testing Program SR 3.6.1.3.11 Verify combined leakage through water tested In accordance lines that penetrate primary containment are with the Primary within the limits specified in the Primary Containment Containment Leakage Rate Testing Program.

Leakage Rate Testing Program BFN-UNIT 1 BFNUNI I3.6-16 Amendment No. 231, 261, 263-, 264