NAI Report Release Page 1 of 196 Calculation Number: NAI-1149018 Revision Number: 1

Title:

Palisades Design Basis Main Steam Line Break AST Radiological Analysis

==

Description:==

1 1

I Revision O This calculation reanalyzes the radlolo~lcaf consequences of the Main Steam Line Break event I presented in Section 14.14.3 of the ~aisades FSAR using the AST methodology described in USNRC Reg. Guide 1.1 83.

!&vision 1 Revision 1 is Issued to credit the reduction in control room unfiltered inleakage afforded by the installation of bubble-tight dampers.

0 C p - 68-z ~ Q Q Date Mff Voskuil M.vthhpr 6 0 6 Reviewer Date Mark Pope NAI Management Tom George

Page 2 of 196 NAI Calculation Approval Calculation Number: NAI-1149-018 Revision Number: 1

Title:

Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation

Description:

I Revision 0 This calculation reanalyzes the radiological consequences of the Main Steam Line Break event presented in Section 14.14.3 of the Palisades FSAR using the AST methodology described in USNRC Reg. Guide 1.183.

Revision 1 Revision 1 is issued to credit the reduction in control room unfiltered inleakage afforded by the installation of bubble-tight dampers.

Page 3 of 196 Scope of Review:

Review included:

o A review of calculation methods was completed for consistency with plant-specific and generic regulatory requirements and guidance.

o Computer codes (RADTRAD-NAI) were checked for appropriate qualification.

o Calculation and code inputs and assumptions were verified against IAM document(s) andlor checked for reasonableness and conservatism.

o Computations were checked for correctness.

o References were verified as appropriate.

o Outputs from spreadsheets and utility programs were checked.

o Reported Results were verified against computer outputs.

o Results and conclusions were reviewed for reasonableness.

o Cases run were checked against procurement documents.

Design Verification -

See Attachment 1 for Revision 0 comments See Attachment 7 for Revision 1 comments.

6-8-06 Reviewer Date Mark Pope

Page 4 of 196 Check items in the following lists to verify that project documentation and engineering calculations are complete. Mark any items that are not applicable with N/A notation.

Project Documentation Checklist:

Project QA Plan.

Project Organization.

Project Work Scope and Design Plan.

Project Calculation and Document Index.

Project QA Requirements.

Project Engineer Training and Qualification Forms.

Project QA Training Certification Forms.

Project Correspondence.

Engineering Calculations Checklist:

d Identification by subject, originator, reviewer, date and Project so that the calculation is retrievable.

r/

Table of contents.

d Statement of the objective of the analysis.

nalysis inputs and their sources.

Assumptions and how they were developed or determined.

P

/Hand calculations.

d~dentification of computer calculations, including computer type, computer program name and version, code input and output.

0" Conclusions.

/Review summary.

p/Responses to review comments.

d References.

d ~ a c h page of the calculation shall be numbered and the first page shall indicate the total number of pages. The calculation pages may be numbered by sections with the st page of the section indicating the total number of pages in the section.

Calculation Approval Sheet shall be signed and dated by the originator.

Numerical Applications Inc. Page 5 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1149-018 Rev. 1 Table of Contents

1.0 INTRODUCTION

............................................................................................................................ 7 2.0

SUMMARY

OF RESULTS............................................................................................................. 9 3.0 DESIGN INPUT............................................................................................................................. 10 3.1 SOURCE TERM INPUT.................................................................................................................... 10 3.2 OTHER INPUT................................................................................................................................ 11 4.0 ASSUMPTIONS............................................................................................................................. 12 5.0 ACCEPTANCE CRITERIA.......................................................................................................... 13 6.0 COMPUTER CODES.................................................................................................................... 13 7.0 CALCULATIONS.......................................................................................................................... 14 7.1 NOBLE GAS DOSE RADTRAD-NAI MODEL................................................................................ 14 7.1.1 PCS Compartment................................................................................................................ 16 7.1.2 Environment Compartment................................................................................................... 16 7.1.3 Control Room Compartment................................................................................................. 16 7.1.4 Steam Generator Tube Leakage to Environment Pathway................................................... 16 7.1.5 Control Room Unfiltered Makeup........................................................................................ 17 7.1.6 Control Room Filtered Makeup............................................................................................ 17 7.1.7 Control Room Unfiltered Inleakage..................................................................................... 18 7.1.8 Control Room Exhaust.......................................................................................................... 18 7.1.9 Plant Power and Release Information.................................................................................. 18 7.1.10 Dose Location Information................................................................................................... 19 7.1.11 Source Term.......................................................................................................................... 21 7.1.12 Noble Gas Release Fraction Timing File............................................................................. 21 7.2 FUEL DAMAGE IODINE DOSE RADTRAD-NAI MODEL............................................................... 23 7.2.1 PCS Compartment................................................................................................................ 25 7.2.2 Environment and Control Room Compartments................................................................... 25 7.2.3 Faulted Steam Generator Compartment............................................................................... 25 7.2.4 Intact Steam Generator Compartment.................................................................................. 25 7.2.5 Tube Leakage to Faulted Steam Generator Pathway........................................................... 25 7.2.6 Control Room Pathways....................................................................................................... 26 7.2.7 Tube Leakage to Intact Steam Generators Pathway............................................................. 26 7.2.8 Steam Release From Intact Steam Generator Pathway........................................................ 27 7.2.9 Steam Release From Faulted Steam Generator Pathway..................................................... 27 7.2.10 Plant Power and Release Information.................................................................................. 28 7.2.11 Dose Location Information................................................................................................... 28 7.2.12 Source Term.......................................................................................................................... 29 7.2.13 Fuel Damage Iodine Release Fraction Timing File............................................................. 30 7.3 SECONDARY ACTIVITY IODINE DOSE RADTRAD-NAI MODEL................................................... 31

8.0 REFERENCES

............................................................................................................................... 33 9.0 MSLB RADTRAD-NAI ANALYSIS FILES................................................................................ 34

Numerical Applications Inc. Page 6 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1149-018 Rev. 1 Tables Table 2-1 MSLB Radiological Dose............................................................................................... 9 Table 3-1 MSLB Source Term..................................................................................................... 10 Table 7-1 Noble Gas Release Fraction Timing File.................................................................... 21 Table 7-2 Fuel Damage Iodine Release Fraction Timing File..................................................... 30 Table 7-3 Secondary Activity Dose Release Fraction Timing File.............................................. 32 Figures Figure 1 Noble Gas RADTRAD-NAI Model................................................................................. 15 Figure 2 Fuel Damage Iodine Dose RADTRAD-NAI Model........................................................ 24 Attachments Verification Comments for Calculation NAI-1149-018 Rev. 0.............................. 35 Palisades MSLB Design Basis Source Term........................................................ 37 RADTRAD-NAI Dose Conversion Factor File....................................................... 51 Palisades MSLB Noble Gas Dose (pal_MSLB_ng_db_ast.out)........................... 68 Palisades MSLB Iodine Dose (pal_MSLB_iodine_db_ast.out)............................. 99 Palisades MSLB Secondary Dose (pal_MSLB_sg_db_ast.out)......................... 154 Verification Comments for Calculation NAI-1149-018 Rev. 1............................ 196

Numerical Applications Inc. Page 7 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1149-018 Rev. 1 1.0 Introduction The purpose of this calculation is to reanalyze the radiological consequences of the Main Steam Line Break (MSLB) event presented in Section 14.14.3 of the Palisades FSAR (Reference 2).

This reanalysis will use the AST dose methodology described in Regulatory Guide 1.183 (Reference 1).

Appendix E of Reg. Guide 1.183 specifies the cases that must be considered for a MSLB event:

2.

If no or minimal2 fuel damage is postulated for the limiting event, the activity released should be the maximum coolant activity allowed by the technical specifications. Two cases of iodine spiking should be assumed.

2 The activity assumed in the analysis should be based on the activity associated with the projected fuel damage or the maximum technical specification values, whichever maximizes the radiological consequences. In determining dose equivalent I-131 (DE I-131), only the radioiodine associated with normal operations or iodine spikes should be included. Activity from projected fuel damage should not be included.

Per Palisades Tech. Spec. LCO 3.4.16, the maximum allowable iodine concentration is 40.0 Ci/gm D.E. I-131. The table presented below lists the PCS iodine concentrations for 2% fuel failure (cladding damage or DNB) with a peaking factor of 2.04:

Core Activity Peaking Gap Damage Release PCS Ci/gm Curies Fraction Fraction Curies grams I-131 7.4830E+07 2.04 0.08 0.02 2.44E+05 2.08E+08 1172.0 I-132 1.0680E+08 2.04 0.05 0.02 2.18E+05 2.08E+08 1045.5 I-133 1.4620E+08 2.04 0.05 0.02 2.98E+05 2.08E+08 1431.1 I-134 1.6020E+08 2.04 0.05 0.02 3.27E+05 2.08E+08 1568.2 I-135 1.3720E+08 2.04 0.05 0.02 2.80E+05 2.08E+08 1343.0 Note: the values above were copied from a spreadsheet; therefore, all of the significant figures are not displayed.

The Ci/gm of I-131 alone exceeds 40 Ci/gm of Dose Equivalent I-131; thus, the activity from 2% fuel failure exceeds that for the pre-accident spike. The iodine Core Activity listed in the table above corresponds to the the total iodine activities in the Palisades design basis AST LOCA source term. The radial peaking factor of 2.04 is from Reference 14, the gap fractions are from Reg. Guide 1.183, the fuel clad damage fraction of 2% for MSLB is from Reference 15, and the PCS mass in grams in from Reference 7.

Numerical Applications Inc. Page 8 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1149-018 Rev. 1 Reference 7 presents the derivation of the amount of iodine released by a concurrent iodine spike. Applying an appearance rate multiplier of 500 (required for concurrent iodine spike by Reg. Guide 1.183) for the MSLB produces the following:

1.0 uCi/gm Iodine Iodine Iodine Iodine D.E I-131 RCS Mass Activity Removal Appearance X 500 Appearance 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> Nuclide concentrations gm Ci min

-1 Ci/min Ci/min Ci I-131 8.305E-01 2.084E+08 1.731E+02 0.001002 0.1734 500 86.7114868 4.162E+04 I-132 1.917E-01 2.084E+08 3.995E+01 0.005965 0.2383 500 119.152137 5.719E+04 I-133 8.624E-01 2.084E+08 1.797E+02 0.001497 0.2690 500 134.524016 6.457E+04 I-134 7.510E-02 2.084E+08 1.565E+01 0.01412 0.2210 500 110.495326 5.304E+04 I-135 3.673E-01 2.084E+08 7.655E+01 0.00269 0.2059 500 102.953824 4.942E+04 A comparison of the total iodine released over 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> from the above table to the iodine release for 2% fuel failure from the previous table shows that the concurrent iodine spike release is also bounded by the release from 2% fuel failure. Therefore, only the 2% fuel damage case will be analyzed.

Note:

The potential exists for operators to isolate auxiliary feedwater flow to the faulted steam generator anywhere from 0 to 30 minutes following the main steam line break (versus the traditionally assumed operator action time of 10 minutes). The maximum HZP steam generator inventory was used for the faulted steam generator for the MSLB dose analysis. The excess liquid inventory (relative to the lower HFP steam generator inventory) and the instantaneous inventory release provide sufficient conservatism with respect to an operator action time of 30 minutes to isolate AFW flow.

Numerical Applications Inc. Page 9 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1149-018 Rev. 1 2.0 Summary of Results Table 2-1 presents the results of the MSLB. The control room shine dose is the sum of the cloud and filter doses from Table 1 of Reference 13.

Table 2-1 MSLB Radiological Dose TEDE Dose (rem)

Dose Contribution EAB LPZ CR Noble Gas Dose 3.1700E-02 5.8465E-03 7.0375E-03 PCS Iodine Dose 2.3697E+00 7.5497E-01 4.0423E+00 S/G Initial Iodine Dose 5.7666E-02 7.5222E-03 6.6577E-01 Control Room Shine Dose 0.268 Total 2.46 0.77 4.98 Acceptance Criteria 25 25 5

Control Room Unfiltered Inleakage = 10 cfm

Numerical Applications Inc. Page 10 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1149-018 Rev. 1 3.0 Design Input 3.1 Source Term Input 4 of Reference 8 presents the design basis AST source term for the Palisades LOCA. The Curies entry of this file provides the source term for the entire core with an average assembly burnup of 39,300 MWD/MTU and a core power level of 2703 MWth (including uncertainty). This file provides the input for the determination of the MSLB event source term.

The RADTRAD-NAI release fraction timing file is used to account for the radial peaking factor (2.04), fraction of fuel damage (2% from Reference 15), and gap release fractions for the various nuclides (listed in Table 3 of Reg. Guide 1.183). The gap fraction for I-131 is 0.08 versus 0.05 for the other iodine isotopes; therefore, the I-131 activity was increased by a factor of 0.08/0.05. The Kr-85 gap fraction is 0.10 versus 0.05 for the other noble gases; therefore, the Kr-85 activity was increased by a factor of 0.10/0.05. Listed below is the MSLB source term with the adjustments for I-131 and Kr-85. The corresponding RADTRAD-NAI file is pal_mslb_db_ast.nif (Attachment 2).

Table 3-1 MSLB Source Term Nuclide Curies Nuclide Curies Co-58 0.0000E+00 Pu-239 0.3558E+05 Co-60 0.0000E+00 Pu-240 0.5406E+05 Kr-85 0.2104E+07 Pu-241 0.1522E+08 Kr-85m 0.1948E+08 Am-241 0.1884E+05 Kr-87 0.3756E+08 Cm-242 0.5669E+07 Kr-88 0.5286E+08 Cm-244 0.5943E+06 Rb-86 0.1959E+06 I-130 0.3743E+07 Sr-89 0.7213E+08 Kr-83m 0.9119E+07 Sr-90 0.8458E+07 Xe-138 0.1211E+09 Sr-91 0.8874E+08 Xe-131m 0.8346E+06 Sr-92 0.9557E+08 Xe-133m 0.4659E+07 Y-90 0.8737E+07 Xe-135m 0.2999E+08 Y-91 0.9264E+08 Cs-138 0.1340E+09 Y-92 0.9596E+08 Cs-134m 0.4920E+07 Y-93 0.1101E+09 Rb-88 0.5369E+08 Zr-95 0.1236E+09 Rb-89 0.6895E+08 Zr-97 0.1206E+09 Sb-124 0.1702E+06 Nb-95 0.1249E+09 Sb-125 0.1567E+07 Mo-99 0.1368E+09 Sb-126 0.1107E+06 Tc-99m 0.1198E+09 Te-131 0.6601E+08 Ru-103 0.1260E+09 Te-133 0.8639E+08 Ru-105 0.9451E+08 Te-134 0.1220E+09 Ru-106 0.5794E+08 Te-125m 0.3413E+06 Rh-105 0.8741E+08 Te-133m 0.5406E+08 Sb-127 0.9111E+07 Ba-141 0.1188E+09

Numerical Applications Inc. Page 11 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1149-018 Rev. 1 Nuclide Curies Nuclide Curies Sb-129 0.2568E+08 Ba-137m 0.1043E+08 Te-127 0.9047E+07 Pd-109 0.3327E+08 Te-127m 0.1223E+07 Rh-106 0.6285E+08 Te-129 0.2528E+08 Rh-103m 0.1135E+09 Te-129m 0.3772E+07 Tc-101 0.1261E+09 Te-131m 0.1113E+08 Eu-154 0.1247E+07 Te-132 0.1048E+09 Eu-155 0.8448E+06 I-131 0.1197E+09 Eu-156 0.2023E+08 I-132 0.1068E+09 La-143 0.1108E+09 I-133 0.1462E+09 Nb-97 0.1216E+09 I-134 0.1602E+09 Nb-95m 0.8835E+06 I-135 0.1372E+09 Pm-147 0.1292E+08 Xe-133 0.1466E+09 Pm-148 0.2144E+08 Xe-135 0.4692E+08 Pm-149 0.4541E+08 Cs-134 0.2037E+08 Pm-151 0.1606E+08 Cs-136 0.5873E+07 Pm-148m 0.2999E+07 Cs-137 0.1100E+08 Pr-144 0.1025E+09 Ba-139 0.1307E+09 Pr-144m 0.1224E+07 Ba-140 0.1260E+09 Sm-153 0.4423E+08 La-140 0.1299E+09 Y-94 0.1105E+09 La-141 0.1193E+09 Y-95 0.1183E+09 La-142 0.1156E+09 Y-91m 0.5151E+08 Ce-141 0.1212E+09 Br-82 0.5282E+06 Ce-143 0.1115E+09 Br-83 0.9102E+07 Ce-144 0.1020E+09 Br-84 0.1591E+08 Pr-143 0.1111E+09 Am-242 0.9062E+07 Nd-147 0.4770E+08 Np-238 0.4306E+08 Np-239 0.1830E+10 Pu-243 0.4690E+08 Pu-238 0.3927E+06 3.2 Other Input Reference 5 lists other input, provided by Palisades, used in the development of the Palisades MSLB RADTRAD-NAI models.

Control room unfiltered inleakage is taken as 10 cfm based on the modification to install bubble tight dampers and subsequent post-modification testing, as indicated in the assumption section below.

Numerical Applications Inc. Page 12 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1149-018 Rev. 1 4.0 Assumptions Operator action and makeup flow from the auxiliary feedwater system are assumed to maintain a constant mass on the secondary side of the intact steam generator. This is consistent with assumptions for the MSLB analysis described in Reference 10 and approved by the NRC in Reference 12.

The initial concentration of the I-131 on the secondary side was set to 0.1 uCi/gm I-131 (Tech. Spec. LCO 3.7.17).

The steam generator mass for the intact steam generator is assumed to be the minimum (HFP) value. This is a conservative assumption that maximizes the nuclide concentration available for release from the intact steam generator.

The steam generator mass for the faulted steam generator is assumed to be the maximum (HZP) value. This is a conservative assumption that maximizes the amount of secondary activity released from the faulted steam generator.

The faulted steam generator is assumed to blow down near instantaneously.

The steam generator tube leakage ceases at 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> (time for the PCS to reach 212oF).

Releases from the intact steam generator were assumed to cease at 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> (time of SDC initiation).

Tube leakage to the faulted steam generator is assumed to flash and leak directly to the environment.

All noble gases are assumed to leak directly to the environment.

The control room unfiltered inleakage is assumed to be 10 cfm. Control room HVAC dampers D-1, D-2, D-8, D-9, D-15, and D-16 are to be replaced to support this assumption.

Post-modification and periodic tracer gas testing to confirm control room envelope inleakage assumptions are also required.

Numerical Applications Inc. Page 13 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1149-018 Rev. 1 5.0 Acceptance Criteria Per Section 4.4 and Table 6 of Reg. Guide 1.183, the acceptable dose limits for the Exclusion Area Boundary (EAB), Low Population Zone (LPZ), and Control Room (CR) for the MSLB with fuel damage are:

MSLB With Fuel Failure Dose Limits Area Dose Criteria EAB 25 rem TEDE (worst 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />)

LPZ 25 rem TEDE (30 days)

Control Room 5 rem TEDE (30 days)*

  • Reg. Guide 1.183 and 10CFR50.67 6.0 Computer Codes The following computer code was used for performing the analyses presented in this calculation:

Computer Code Version Reference Purpose RADTRAD-NAI 1.1a(QA) 3 Radiological Dose Calculations RADTRAD-NAI (Reference 3) is qualified and maintained under the Numerical Applications Inc.

QA program (Reference 4). This QA program meets the requirements of 10CFR50 Appendix B with code error reporting per 10CFR21. RADTRAD-NAI is accessed via a controlled access web-based interface that provides a front-end for developing and submitting input models. The input developed via the interface is submitted to the RADTRAD-NAI solver that runs on an AMD-ATHLON based personal computer running LINUX.

Numerical Applications Inc. Page 14 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1149-018 Rev. 1 7.0 Calculations Section 5 of Appendix E to Reg. Guide 1.183 sets the requirements for the transport, reduction, and release of radionuclides for the MSLB. The transport model specified for noble gases is different than that specified for the non-noble gas nuclides; therefore, a separate RADTRAD model was required for determining the noble gas dose.

The MSLB consists of a dose contribution from several sources. Therefore, separate RADTRAD models were required to calculate the dose from each source. Listed below are the RADTRAD models produced for determining the individual dose contributions:

Dose from noble gas release from failed fuel (Section 7.1)

Dose from non-noble gas release from failed fuel (Section 7.2)

Dose from initial activity on the secondary side of the steam generators (Section 7.3) 7.1 Noble Gas Dose RADTRAD-NAI Model Section 5.4 of Appendix E to Reg. Guide 1.183 specifies the method for handling noble gases:

All noble gas radionuclides released from the primary system are assumed to be released to the environment without reduction or mitigation.

The RADTRAD-NAI model developed for the noble gas calculation consists of three compartments and 5 pathways (see Figure 1). The corresponding RADTRAD-NAI model output pal_MSLB_ng_db_ast.out (Attachment 4).

Compartment Description Compartment Number RADTRAD-NAI Compartment Type PCS 1

(3) Normal Environment 2

(2) Environment Control Room 3

(1) Control Room Pathway Description Compartment Connections Pathway Number RADTRAD-NAI Pathway Type S/G Tube Leakage 1 to 2 1

Filtered Control Room Unfiltered Makeup 2 to 3 2

Filtered Control Room Filtered Makeup 2 to 3 3

Filtered Control Room Unfiltered Inleakage 2 to 3 4

Filtered Control Room Exhaust 3 to 2 5

Filtered The subsections that follow describe the RADTRAD-NAI input for the noble gas model. The noble gas RADTRAD-NAI model was set up on a mass flow basis rather than the typical volumetric flow basis; therefore, the RCS volume was specified as lbm and the steam generator tube leakage was specified as lbm/min.

Numerical Applications Inc. Page 15 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1149-018 Rev. 1 Figure 1 Noble Gas RADTRAD-NAI Model Compartment 1 PCS Compartment 2 Environment Compartment 3 Control Room S/G Tube Leakage Exhaust Flow Unfiltered Makeup Unfiltered Inleakage Filtered Makeup

Numerical Applications Inc. Page 16 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1149-018 Rev. 1 7.1.1 PCS Compartment To conservatively maximize the PCS nuclide concentration from the damaged fuel, the minimum PCS volume minus the pressurizer volume was used. From Reference 16 this volume is 9400 ft3.

At system conditions of 2060 psia and 560oF (Reference 7), the PCS mass is:

(9400 ft3) / (2.171017E-2 ft3/lbm) = 432,977 lbm The following input was specified for the PCS Compartment:

Volume 432,977 lbm Source Fraction 1.0 100% of source term applied to PCS volume Recirculation Filters no Natural Deposition no 7.1.2 Environment Compartment The only required input for the environment compartment is volume. This value is a dummy value; however, an input is required for this field. An arbitrary value of 2.0E20 ft3 was specified.

7.1.3 Control Room Compartment The control room volume was set to 35,923 ft3. The control room HVAC system is assumed to be operating in normal mode at the beginning of the event. The control room enters emergency filtration mode at 20 minutes.

Filter Efficiency Time (hours)

Flow Rate (cfm)

Aerosol Elemental Organic 0.0 0.0 99 99 99 0.3333 1413.6 99 99 99 720.0 1413.6 99 99 99 7.1.4 Steam Generator Tube Leakage to Environment Pathway This pathway, which models the total steam generator tube leakage, connects the PCS (Compartment 1) with the Environment Compartment (Compartment 2). The limit for steam generator tube leakage is 432 gallon per day (0.3 gpm) to any single SG (Palisades Tech. Spec.

LCO 3.4.13). Item 5.2 of Appendix E to Reg. Guide 1.183 states:

The density used in converting volumetric leak rates (e.g., gpm) to mass leak rates (e.g., lbm/hr) should be consistent with the basis of the parameter being converted. The ARC leak rate correlations are generally based on the collection of cooled liquid. Surveillance tests and facility instrumentation used to show compliance with leak rate technical specifications are typically based on cooled liquid. In most cases, the density should be assumed to be 1.0 gm/cc (62.4 lbm/ft3).

Numerical Applications Inc. Page 17 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1149-018 Rev. 1 The Palisades leak rate testing results are adjusted so that the allowable leakage corresponds to a density of 1.0 gm/cc (62.4 lbm/ft3).

The total leak mass flow rate is:

SG Tube Leak rate = (0.3 gpm/SG)(2 SG)(0.13368 ft3/gal)(62.4 lbm/ft3) = 5.005 lbm/min The tube leakage ceases at 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> (time to reach 212oF):

Filter Efficiency Time (hours)

Flow Rate (lb/min)

Aerosol Elemental Organic 0.0 5.005 0

0 0

12.0 0.0 0

0 0

720.0 0.0 0

0 0

7.1.5 Control Room Unfiltered Makeup The unfiltered makeup flow covers two time periods. During the first 20 minutes, the normal makeup flow is 660.0 cfm. After control room isolation at 20 minutes, the flow is 0 cfm.

Unfiltered Makeup Flow Filter Efficiency Time (hours)

Flow Rate (cfm)

Aerosol Elemental Organic 0.0 660.0 0

0 0

0.3333 0.0 0

0 0

720.0 0.0 0

0 0

7.1.6 Control Room Filtered Makeup The control room filtered makeup flow of 1413.6 cfm starts at 20 minutes (time of control room isolation).

Filtered Makeup Flow Filter Efficiency Time (hours)

Flow Rate (cfm)

Aerosol Elemental Organic 0.0 0.0 99 99 99 0.3333 1413.6 99 99 99 720.0 1413.6 99 99 99

Numerical Applications Inc. Page 18 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1149-018 Rev. 1 7.1.7 Control Room Unfiltered Inleakage The unfiltered inleakage was set to 10 cfm. The normal unfiltered intake flow rate includes any unfiltered inleakage when the control room ventilation system is operating in normal mode.

Unfiltered Inleakage Filter Efficiency Time (hours)

Flow Rate (cfm)

Aerosol Elemental Organic 0.0 0.0 0

0 0

0.3333 10.0 0

0 0

720.0 10.0 0

0 0

7.1.8 Control Room Exhaust The control room exhaust is equal to the sum of the control room intake and inleakage flows.

Exhaust Flow Filter Efficiency Time (hours)

Flow Rate (cfm)

Aerosol Elemental Organic 0.0 660.0 0

0 0

0.3333 1423.6 0

0 0

720.0 1423.6 0

0 0

7.1.9 Plant Power and Release Information The nuclide inventory file containing the source term is pal_mslb_db_ast.nif. The nif file lists the source term in terms of Curies and the reference power level in the nif file is 2703. The total source term is defined by the combination of the nif file activities, the nif file reference power level, the plant power input to the RADTRAD model, and the release fractions specified in the release fraction timing file (rft file). The plant power input was set to 2703 to match the power in the nif file.

Dummy values were specified for the iodine fractions (no iodine release for the Noble Gas case).

Start of first release time (hours) 0.0 Calculate decay yes Calculate daughters yes Iodine Fraction - aerosol 1.0 Iodine Fraction - elemental 0.0 Iodine Fraction - organic 0.0

Numerical Applications Inc. Page 19 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1149-018 Rev. 1 7.1.10 Dose Location Information Three dose locations were specified; the Exclusion Boundary (EAB), the Low Population Zone (LPZ), and the Control Room (CR). The X/Qs for the EAB and LPZ are from Table 5 of Reference 11. The breathing rates are from Section 4.1.3 of Reg. Guide 1.183:

Exclusion Boundary Data:

Table 1 - EAB X/Q Time (hours)

X/Q (sec/m3) 0.0 5.39E-4 720.0 5.39E-4 EAB and LPZ Breathing Rate Time (hours)

Breathing Rate (m3/sec) 0.0 3.5E-4 8.0 1.8E-4 24.0 2.3E-4 720.0 2.3E-4 Low Population Zone Data:

Table 2 - LPZ X/Q Time (hours)

X/Q (sec/m3) 0.0 6.66E-5 2.0 3.03E-5 8.0 2.04E-5 24.0 8.67E-6 96.0 2.54E-6 720.0 2.54E-6

Numerical Applications Inc. Page 20 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1149-018 Rev. 1 The breathing rates and occupancy factor for the control room are from Section 4.2.6 of Reg.

Guide 1.183. All of the noble gas is conservatively assumed to exit the steam line break. The X/Qs correspond to the turbine building roof exhauster and are listed in Table 4 of Reference 11.

Control Room Data:

Table 3 - Control Room X/Q (Line Break to Normal Intake)

Time (hours)

X/Q (sec/m3) 0.0 1.31E-2 2.0 1.13E-2 8.0 4.68E-3 24.0 2.87E-3 96.0 2.36E-3 720.0 2.36E-3 Table 4 - Control Room X/Q (Line Break to Emergency Intake)

Time (hours)

X/Q (sec/m3) 0.0 7.99E-4 2.0 6.43E-4 8.0 2.58E-4 24.0 1.75E-4 96.0 1.32E-4 720.0 1.32E-4 Control Room Breathing Rate Time (hours)

Breathing Rate (m3/sec) 0.0 3.5E-4 720.0 3.5E-4 Control Room Occupancy Factor Time (hours)

Factor 0.0 1.0 24.0 0.6 96.0 0.4 720.0 0.4

Numerical Applications Inc. Page 21 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1149-018 Rev. 1 Dose Location Pathway Combinations Control Room Intake Path Release Path X/Q Table 2

1 3

3 1

4 4

1 3

7.1.11 Source Term Section 3.4 of Reg. Guide 1.183 specifies the radionuclide groups that should be considered for radiological analyses. Reference 9 provides a listing of the individual nuclides and dose conversion factors used for the analyses presented in this calculation. The data provided in Reference 9 are consistent with Section 3.4 of Reg. Guide 1.183. The dose conversion factors provided in Reference 9 were obtained from Table 2.1 of Federal Guidance Report 11 and Table III.1 of Federal Guidance Report 12. The RADTRAD-NAI dose conversion factor file, nai-1101-001rev0.dcf, is provided in Attachment 3.

The source term is given in Table 3-1. The corresponding nuclide inventory file is pal_mslb_db_ast.nif (Attachment 2) 7.1.12 Noble Gas Release Fraction Timing File Table 7-1 presents the release fraction timing file, pal_ mslb noblegas_db.rft, used for the noble gas case. The release fractions for all non-noble gas nuclides were set to zero. The release fraction for the noble gas was set to the gap fraction with adjustments for the peaking factor and fraction of fuel damaged:

release fraction = (0.05)(2.04)(0.02) = 0.00204 Table 7-1 Noble Gas Release Fraction Timing File Release Fraction and Timing Name:

PWR, NUREG 1.183, Palisades MSLB Noble Gas Release Duration (h): Design Basis Accident 0.1000E-02 0.0000E+00 0.0000E+00 0.0000E+00 Noble Gases:

0.2040E-02 0.0000E+00 0.0000E+00 0.0000E+00 Iodine:

0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Cesium:

0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Tellurium:

0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Strontium:

0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00

Numerical Applications Inc. Page 22 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1149-018 Rev. 1 Barium:

0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Ruthenium:

0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Cerium:

0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Lanthanum:

0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Non-Radioactive Aerosols (kg):

0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 End of Release File

Numerical Applications Inc. Page 23 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1149-018 Rev. 1 7.2 Fuel Damage Iodine Dose RADTRAD-NAI Model The RADTRAD-NAI model developed for the fuel damage iodine dose calculation consists of five compartments and 8 pathways (see Figure 2). The corresponding RADTRAD-NAI model output is pal_MSLB_iodine_db_ast.out (Attachment 5).

Compartment Description Compartment Number RADTRAD-NAI Compartment Type PCS 1

(3) Normal Environment 2

(2) Environment Control Room 3

(1) Control Room Faulted S/G 4

(3) Normal Intact S/G 5

(3) Normal Pathway Description Compartment Connections Pathway Number RADTRAD-NAI Pathway Type Faulted S/G Tube Leakage 1 to 2 1

Filtered Control Room Unfiltered Makeup 2 to 3 2

Filtered Control Room Filtered Makeup 2 to 3 3

Filtered Control Room Unfiltered Inleakage 2 to 3 4

Filtered Control Room Exhaust 3 to 2 5

Filtered Intact S/G Tube Leakage 1 to 5 6

Filtered Intact S/G Steam Release 5 to 2 7

Filtered Faulted S/G Steam Release 4 to 2 8

Filtered Two cases were run with the fuel damage iodine model:

Dose due to damaged fuel iodine and cesium activity (Section 7.2)

Dose due to initial S/G iodine activity (Section 7.3)

The subsections that follow describe the input for the fuel damage iodine dose model. The RADTRAD-NAI model was set up on a mass flow basis rather than the typical volumetric flow basis; therefore, the RCS volume was specified as lbm and the steam generator leakage and steam release rates were specified as lbm/min.

Numerical Applications Inc. Page 24 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1149-018 Rev. 1 Figure 2 Fuel Damage Iodine Dose RADTRAD-NAI Model Compartment 1 PCS Compartment 2 Environment Compartment 3 Control Room Tube Leakage to faulted S/G (assumed to leak directly to environment)

Exhaust Flow Unfiltered Inleakage Filtered Makeup Compartment 4 Faulted S/G Compartment 5 Intact S/G Tube Leakage to Intact S/G Steam release from faulted S/G Steam release from intact S/G Unfiltered Makeup

Numerical Applications Inc. Page 25 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1149-018 Rev. 1 7.2.1 PCS Compartment The input for this compartment is the same as that used for the noble gas model (Section 7.1.1).

7.2.2 Environment and Control Room Compartments The input for these compartments is the same as that used for the noble gas model (Sections 7.1.2 and 7.1.3).

7.2.3 Faulted Steam Generator Compartment The following input was specified for the Faulted Steam Generator Compartment:

Volume 210,759 lbm Calculation performed on a lbm basis; therefore, faulted S/G water mass is input. Maximum S/G water mass corresponding to HZP is used to maximum source.

Source Fraction 0

Dose due to RCS leakage only, dose due to initial secondary activity is calculated in Section 7.3.

Recirculation Filters no Natural Deposition no 7.2.4 Intact Steam Generator Compartment The following input was specified for the Intact Steam Generator Compartment:

Volume 141,065 lbm Calculation performed on a lbm basis; therefore, intact S/G water mass is input. Minimum S/G mass corresponding to HFP is used to maximize concentration.

Source Fraction 0

Dose due to RCS leakage only, dose due to initial secondary activity is calculated in Section 7.3.

Recirculation Filters no Natural Deposition no 7.2.5 Tube Leakage to Faulted Steam Generator Pathway The faulted steam generator is assumed to blow down and boil dry within a relatively short period of time (see Section 7.2.8). As a result, no credit for iodine partitioning can be taken for the RCS leakage into the faulted steam generator. Thus, the RCS leakage into the faulted steam generator was assumed to leak directly to the environment.

Numerical Applications Inc. Page 26 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1149-018 Rev. 1 This pathway connects the RCS (Compartment 1) with the Environment (Compartment 2). The Tech. Spec. limit for steam generator tube leakage is 0.3 gpm per steam generator. The leak mass flow rate to the faulted steam generator is:

leak rate = (0.3 gal/min)(0.13368 ft3/gal)(62.4 lbm/ft3) leak rate = 2.5025 lbm/min The tube leakage to the faulted steam generator ceases at 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> (time for PCS to reach 212oF):

Filter Efficiency Time (hours)

Flow Rate (lbm/min)

Aerosol Elemental Organic 0.0 2.5025 0

0 0

12.0 0.0 0

0 0

720.0 0.0 0

0 0

7.2.6 Control Room Pathways The input for the control room pathways is the same as that used for the noble gas model (Sections 7.1.5, 7.1.6, 7.1.7, and 7.1.8).

7.2.7 Tube Leakage to Intact Steam Generators Pathway This pathway connects the RCS (Compartment 1) with the Intact Steam Generators (Compartment 5). The leak rate is the same as that for the faulted steam generator pathway.

Per Reference 5, the tubes in the intact steam generators remain covered during the MSLB; therefore, the tube leakage can be assumed to mix with the fluid on the secondary side.

The tube leakage to the intact steam generators ceases at 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> (time for PCS to reach 212oF):

Filter Efficiency Time (hours)

Flow Rate (lbm/min)

Aerosol Elemental Organic 0.0 2.5025 0

0 0

12.0 0.0 0

0 0

720.0 0.0 0

0 0

Numerical Applications Inc. Page 27 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1149-018 Rev. 1 7.2.8 Steam Release From Intact Steam Generator Pathway This pathway connects the Intact Steam Generator (Compartment 5) with the Environment (Compartment 2). Makeup flow from the auxiliary feedwater system is assumed to maintain a constant mass on the secondary side of the intact steam generator. Section 5.5.4 of Appendix E to Reg. Guide 1.183 states:

The radioactivity in the bulk water is assumed to become vapor at a rate that is the function of the steaming rate and the partition coefficient. A partition coefficient for iodine of 100 may be assumed. The retention of particulate radionuclides in the steam generators is limited by the moisture carryover from the steam generators.

The steam carryover fraction is less than 1%; therefore, a partition coefficient of 100 can be applied to all particulates.

The partition coefficient was modeled by adjusting the steam mass release rates from the intact steam generator by a factor of 0.01. The total steam release of 800,000 lbm (Reference 5) is terminated at 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> (time of SDC initiation).

0-8 hours:

(0.01)(800,000 lbm)/ 480 min

= 16.67 lbm/min Time (hours)

Flow Rate (lbm/min) 0.0 16.67 8.0 0.0 720.0 0.0 7.2.9 Steam Release From Faulted Steam Generator Pathway This pathway connects the Faulted Steam Generator (Compartment 4) with the Environment (Compartment 2). All of the initial steam generator mass is assumed to be released from the faulted steam generator at the beginning of the event. A high flow rate was used to ensure that all of the activity was released from the faulted steam generator.

Filter Efficiency Time (hours)

Flow Rate (lbm/min)

Aerosol Elemental Organic 0.0 1.0e6 0

0 0

720.0 1.0e6 0

0 0

Numerical Applications Inc. Page 28 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1149-018 Rev. 1 7.2.10 Plant Power and Release Information The plant power in the RADTRAD model was set to 2703 so as to match the nominal power in the nuclide inventory file.

The composition of the iodine released from the steam generators during a MSLB is specified in Section 4 of Appendix E to Reg. Guide 1.183 (97% elemental and 3% organic).

Start of first release time (hours) 0.0 Calculate decay yes Calculate daughters yes Iodine Fraction - aerosol 0.0 Iodine Fraction - elemental 0.97 Iodine Fraction - organic 0.03 7.2.11 Dose Location Information The dose location input for the EAB and LPZ are the same as that used for the noble gas model.

The X/Qs for the control room for releases from the faulted steam generator are also the same as those used for the noble gas model. The X/Qs for releases from the ADVs (intact S/G) are listed below:

Table 5 - Control Room X/Q (ADV to Normal Intake)

Time (hours)

X/Q (sec/m3) 0.0 1.65E-2 2.0 1.34E-2 8.0 5.40E-3 24.0 4.03E-3 96.0 2.98E-3 720.0 2.98E-3 Table 6 - Control Room X/Q (ADV to Emergency Intake)

Time (hours)

X/Q (sec/m3) 0.0 7.36E-4 2.0 6.42E-4 8.0 2.43E-4 24.0 1.75E-4 96.0 1.28E-4 720.0 1.28E-4

Numerical Applications Inc. Page 29 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1149-018 Rev. 1 Dose Location Pathway Combinations Control Room Intake Path Release Path X/Q Table 2

1 3

3 1

4 4

1 3

2 7

5 3

7 6

4 7

5 2

8 3

3 8

4 4

8 3

7.2.12 Source Term The source term is the same as that used for the noble gas model (Table 3-1).

Numerical Applications Inc. Page 30 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1149-018 Rev. 1 7.2.13 Fuel Damage Iodine Release Fraction Timing File Table 7-2 presents the release fraction timing file used for the fuel damage iodine dose case.

The noble gas dose was calculated separately; therefore, the noble gas release fraction was set to 0. The release fraction for iodine was set to 0.204E-2 (see Section 7.1.12). The release fraction for alkali metal (cesium) was set to:

(0.12)(2.04)(0.02) = 0.004896 The release fraction timing file name is pal_mslb_iodine_ast_db.rft.

Table 7-2 Fuel Damage Iodine Release Fraction Timing File Release Fraction and Timing Name:

PWR, NUREG 1.183, Palisades AST MSLB Iodine Release Duration (h): Design Basis Accident 0.1000E-02 0.0000E+00 0.0000E+00 0.0000E+00 Noble Gases:

0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Iodine:

0.2040E-02 0.0000E+00 0.0000E+00 0.0000E+00 Cesium:

0.4896E-02 0.0000E+00 0.0000E+00 0.0000E+00 Tellurium:

0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Strontium:

0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Barium:

0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Ruthenium:

0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Cerium:

0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Lanthanum:

0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Non-Radioactive Aerosols (kg):

0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 End of Release File

Numerical Applications Inc. Page 31 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1149-018 Rev. 1 7.3 Secondary Activity Iodine Dose RADTRAD-NAI Model The fuel damage iodine dose model determined the dose due to the iodine released from the damaged fuel; therefore, an additional case was required for calculating the dose due to the initial secondary iodine activity. The corresponding RADTRAD-NAI model output is pal_MSLB_sg_db_ast.out (Attachment 6).

The following changes were made to the fuel damage iodine dose model (Section 7.2) for this run:

The dose due to PCS leakage via the S/G tubes was determined by the fuel damage iodine dose RADTRAD model; therefore, the PCS compartment source fraction was set to zero.

A modified nuclide inventory file was used. In this file, the activity for I-131 was set to 1.0 Ci and the activities for the remaining nuclides were set to zero. The file name is pal_mslb_sg_db.nif.

The initial Tech Spec limit for steam generator activity is 0.1 Ci/gm D.E. I-131. Therefore, the steam generator iodine inventories were determined:

Faulted S/G Source = (0.1Ci/gm)(453.59 gm/lbm)(1 Ci/106 Ci)(210,759 lbm) = 9.56 Ci I-131 Intact S/G Source = (0.1Ci/gm)(453.59 gm/lbm)(1 Ci/106 Ci)(141,065 lbm) = 6.40 Ci I-131 Since the I-131 activity was set to 1.0 Ci in the nif file, the source fractions for the faulted and intact steam generators were set to 9.56 and 6.40 respectively.

The secondary side activity consists of iodine only; therefore, the release fractions for all isotopes other than iodine were set to zero (pal_mslb_sg.rft).

The tube leakage rates were set to zero.

Numerical Applications Inc. Page 32 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1149-018 Rev. 1 Table 7-3 Secondary Activity Dose Release Fraction Timing File Release Fraction and Timing Name:

PWR, NUREG 1.183, Palisades MSLB Secondary Activity Duration (h): Design Basis Accident 0.1000E-02 0.0000E+00 0.0000E+00 0.0000E+00 Noble Gases:

0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Iodine:

0.1000E+01 0.0000E+00 0.0000E+00 0.0000E+00 Cesium:

0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Tellurium:

0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Strontium:

0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Barium:

0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Ruthenium:

0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Cerium:

0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Lanthanum:

0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Non-Radioactive Aerosols (kg):

0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 End of Release File

Numerical Applications Inc. Page 33 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1149-018 Rev. 1 8.0 References

1. USNRC, Regulatory Guide 1.183, Alternative Radiological Source Terms for Evaluating Design Basis Accidents at Nuclear Power Plants, July 2000.
2. Palisades Nuclear Plant FSAR, Revision 24.
3. Numerical Applications Inc., NAI-9912-04, Revision 4, RADTRAD-NAI Version 1.1a(QA)

Documentation, October 2004.

4. Numerical Applications Inc., Dose Methodology Quality Assurance Procedures, Revision 1, June 4, 2001.
5. NAI-E03-211 Project Memo 2004-06, MSLB and SGTR Inputs, July 6 2004.
6. Palisades Plant Technical Specifications through Amendment 213.
7. NAI Calculation Number NAI-1149-019 Rev. 0, Palisades Design Basis Steam Generator Tube Rupture AST Radiological Analysis.
8. NAI Calculation Number NAI-1149-001 Rev. 1, Source Terms for Palisades Dose Calculations.
9. NAI Calculation Number NAI-1101-001 Rev. 1, Generation of.nif and.inp Files for RADTRAD-NAI, August 8, 2002.
10. USNRC, Serial: RNP-RA/02-0067, H.B. Robinson Steam Electric Plant, Unit No. 2 Docket No. 50-261/License No. DPR-23, Request for Technical Specifications Change Regarding Full Implementation of Alternative Radiological Source Term.
11. NAI Calculation Number NAI-1149-002 Rev. 0, Determination of Atmospheric Dispersion Factors for Palisades.
12. USNRC, Safety Evaluation by the Office of Nuclear Reactor Regulation Related to Amendment No. 201 to Renewed Facility Operating License No. DPR-23 Carolina Power &

Light Company H. B. Robinson Steam Electric Plant, Unit No. 2 Docket No. 50-261.

13. NAI Calculation Number NAI-1149-024 Rev. 1, Determination of Direct Shine Doses for a Design Basis LOCA for Palisades.
14. EA-PSA-DOSE-04-01, Revision 0, ORIGEN Source Term Calculation Inputs for Radiological Analyses.
15. NAI-E03-211 Project Memo 2004-09, Additional Inputs, October 20 2004.
16. NAI-E03-211 Project Memo 2004-03, MHA/LOCA Inputs, June 11 2004.

Numerical Applications Inc. Page 34 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1149-018 Rev. 1 9.0 MSLB RADTRAD-NAI Analysis Files RADTRAD-NAI MSLB Case Files File Name Attachment Case Base Cases pal_MSLB_ng_db_ast.out MSLB noble gas dose pal_MSLB_iodine_db_ast.out MSLB iodine and cesium dose pal_MSLB_sg_db_ast.out MSLB secondary side dose RADTRAD-NAI MSLB Nuclide Inventory Files File Name Attachment #

Case pal_mslb_db_ast.nif MSLB source term nai-1101-001rev0 RADTRAD-NAI dose conversion factor file RADTRAD-NAI MSLB Release Fraction Timing Files File Name Table Description pal_mslb_noblegas_db.rft Table 7-1 MSLB noble gas release fraction timing file pal_mslb_iodine_ast_db.rft Table 7-2 MSLB pre-accident iodine spike release fraction timing file pal_mslb_sg.rft Table 7-3 MSLB secondary side release fraction timing file

Numerical Applications Inc. Attachment 1 Page 35 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1149-018 Rev. 1 Verification Comments for Calculation NAI-1149-018 Rev. 0 Comment 1 and TOC - Calculation number should be NAI-1149-018 versus NAI-1131-018.

Response

Corrected.

Comment 2 Page 7, Section 1.0, last paragraph on page, 2nd sentence - Correct typographical error in corresponds.

Response

Corrected.

Comment 3 Page 12, Section 4.0, 1st assumption - Suggest adding reference to NRC SER for Robinson to indicate this approach was approved.

Response

Reference added.

Comment 4 Page 13, Section 5.0 - Please add a note indicating that the control room dose limit is specified in 10CFR50.67.

Response

Note added.

Comment 5 Page 18, Section 7.1.7 - Since the AST calculations will eventually replace the existing Palisades calculations, please remove the reference to EA-TAM-96-02 in this section and remove Reference 12.

Response

Reference deleted.

Comment 6 Page 25, Section 7.2.3 - Please delete the ? note. It appears to already exist on page 8.

Response

Deleted.

Comment 7

- The plant power and PCS volume in the psf file for the fuel damage case are incorrect. The plant power should be 2703 as per Sections 7.2.10 and 7.1.9 of the calculation and the PCS volume should be 432,977 as per Sections 7.2.1 and 7.1.1 of the calculation. These correction should be made and the case should be re-run and the results should be replaced in the attachment and results table.

Numerical Applications Inc. Attachment 1 Page 36 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1149-018 Rev. 1

Response

Corrections made.

Comment 8

- The PCS compartment source fraction was not set to 0 in the psf file for the secondary release case. This correction should be made and the case should be re-run and results replaced in the attachment and results table. Also, suggest making the tube leakage flow to both intact and faulted generators equal to 0. Leaving the tube leakage flow at 2.5025 lbm/min to each of the generators with a 0 source fraction in the PCS will tend to dilute the secondary source. Although the current calculation approach for tube leakage modeling may more accurately reflect the physical configuration, it may not be conservative.

Response

Corrections made.

Numerical Applications Inc. Attachment 2 Page 37 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Palisades MSLB Design Basis Source Term Nuclide Inventory Name:

Palisades AST Design Basis MSLB source term Power Level:

0.2703E+04 Nuclides:

107 Nuclide 001:

Co-58 7

0.6117120000E+07 0.5800E+02 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 002:

Co-60 7

0.1663401096E+09 0.6000E+02 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 003:

Kr-85 1

0.3382974720E+09 0.8500E+02 0.2104E+07 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 004:

Kr-85m 1

0.1612800000E+05 0.8500E+02 0.1948E+08 Kr-85 0.2110E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 005:

Kr-87 1

0.4578000000E+04 0.8700E+02 0.3756E+08 Rb-87 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 006:

Kr-88 1

0.1022400000E+05 0.8800E+02 0.5286E+08 Rb-88 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 007:

Rb-86 3

0.1612224000E+07 0.8600E+02 0.1959E+06 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 008:

Numerical Applications Inc. Attachment 2 Page 38 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Sr-89 5

0.4363200000E+07 0.8900E+02 0.7213E+08 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 009:

Sr-90 5

0.9189573120E+09 0.9000E+02 0.8458E+07 Y-90 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 010:

Sr-91 5

0.3420000000E+05 0.9100E+02 0.8874E+08 Y-91m 0.5780E+00 Y-91 0.4220E+00 none 0.0000E+00 Nuclide 011:

Sr-92 5

0.9756000000E+04 0.9200E+02 0.9557E+08 Y-92 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 012:

Y-90 9

0.2304000000E+06 0.9000E+02 0.8737E+07 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 013:

Y-91 9

0.5055264000E+07 0.9100E+02 0.9264E+08 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 014:

Y-92 9

0.1274400000E+05 0.9200E+02 0.9596E+08 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 015:

Y-93 9

0.3636000000E+05 0.9300E+02 0.1101E+09 Zr-93 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 016:

Zr-95

Numerical Applications Inc. Attachment 2 Page 39 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 9

0.5527872000E+07 0.9500E+02 0.1236E+09 Nb-95m 0.7000E-02 Nb-95 0.9930E+00 none 0.0000E+00 Nuclide 017:

Zr-97 9

0.6084000000E+05 0.9700E+02 0.1206E+09 Nb-97m 0.9470E+00 Nb-97 0.5300E-01 none 0.0000E+00 Nuclide 018:

Nb-95 9

0.3036960000E+07 0.9500E+02 0.1249E+09 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 019:

Mo-99 7

0.2376000000E+06 0.9900E+02 0.1368E+09 Tc-99m 0.8760E+00 Tc-99 0.1240E+00 none 0.0000E+00 Nuclide 020:

Tc-99m 7

0.2167200000E+05 0.9900E+02 0.1198E+09 Tc-99 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 021:

Ru-103 7

0.3393792000E+07 0.1030E+03 0.1260E+09 Rh-103m 0.9970E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 022:

Ru-105 7

0.1598400000E+05 0.1050E+03 0.9451E+08 Rh-105 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 023:

Ru-106 7

0.3181248000E+08 0.1060E+03 0.5794E+08 Rh-106 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 024:

Rh-105 7

Numerical Applications Inc. Attachment 2 Page 40 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 0.1272960000E+06 0.1050E+03 0.8741E+08 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 025:

Sb-127 4

0.3326400000E+06 0.1270E+03 0.9111E+07 Te-127m 0.1760E+00 Te-127 0.8240E+00 none 0.0000E+00 Nuclide 026:

Sb-129 4

0.1555200000E+05 0.1290E+03 0.2568E+08 Te-129m 0.2250E+00 Te-129 0.7750E+00 none 0.0000E+00 Nuclide 027:

Te-127 4

0.3366000000E+05 0.1270E+03 0.9047E+07 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 028:

Te-127m 4

0.9417600000E+07 0.1270E+03 0.1223E+07 Te-127 0.9760E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 029:

Te-129 4

0.4176000000E+04 0.1290E+03 0.2528E+08 I-129 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 030:

Te-129m 4

0.2903040000E+07 0.1290E+03 0.3772E+07 Te-129 0.6500E+00 I-129 0.3500E+00 none 0.0000E+00 Nuclide 031:

Te-131m 4

0.1080000000E+06 0.1310E+03 0.1113E+08 Te-131 0.2220E+00 I-131 0.7780E+00 none 0.0000E+00 Nuclide 032:

Te-132 4

0.2815200000E+06

Numerical Applications Inc. Attachment 2 Page 41 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 0.1320E+03 0.1048E+09 I-132 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 033:

I-131 2

0.6946560000E+06 0.1310E+03 0.1197E+09 Xe-131m 0.1110E-01 none 0.0000E+00 none 0.0000E+00 Nuclide 034:

I-132 2

0.8280000000E+04 0.1320E+03 0.1068E+09 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 035:

I-133 2

0.7488000000E+05 0.1330E+03 0.1462E+09 Xe-133m 0.2900E-01 Xe-133 0.9710E+00 none 0.0000E+00 Nuclide 036:

I-134 2

0.3156000000E+04 0.1340E+03 0.1602E+09 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 037:

I-135 2

0.2379600000E+05 0.1350E+03 0.1372E+09 Xe-135m 0.1540E+00 Xe-135 0.8460E+00 none 0.0000E+00 Nuclide 038:

Xe-133 1

0.4531680000E+06 0.1330E+03 0.1466E+09 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 039:

Xe-135 1

0.3272400000E+05 0.1350E+03 0.4692E+08 Cs-135 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 040:

Cs-134 3

0.6507177120E+08 0.1340E+03

Numerical Applications Inc. Attachment 2 Page 42 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 0.2037E+08 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 041:

Cs-136 3

0.1131840000E+07 0.1360E+03 0.5873E+07 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 042:

Cs-137 3

0.9467280000E+09 0.1370E+03 0.1100E+08 Ba-137m 0.9460E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 043:

Ba-139 6

0.4962000000E+04 0.1390E+03 0.1307E+09 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 044:

Ba-140 6

0.1100736000E+07 0.1400E+03 0.1260E+09 La-140 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 045:

La-140 9

0.1449792000E+06 0.1400E+03 0.1299E+09 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 046:

La-141 9

0.1414800000E+05 0.1410E+03 0.1193E+09 Ce-141 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 047:

La-142 9

0.5550000000E+04 0.1420E+03 0.1156E+09 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 048:

Ce-141 8

0.2808086400E+07 0.1410E+03 0.1212E+09

Numerical Applications Inc. Attachment 2 Page 43 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 049:

Ce-143 8

0.1188000000E+06 0.1430E+03 0.1115E+09 Pr-143 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 050:

Ce-144 8

0.2456352000E+08 0.1440E+03 0.1020E+09 Pr-144m 0.1780E-01 Pr-144 0.9822E+00 none 0.0000E+00 Nuclide 051:

Pr-143 9

0.1171584000E+07 0.1430E+03 0.1111E+09 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 052:

Nd-147 9

0.9486720000E+06 0.1470E+03 0.4770E+08 Pm-147 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 053:

Np-239 8

0.2034720000E+06 0.2390E+03 0.1830E+10 Pu-239 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 054:

Pu-238 8

0.2768863824E+10 0.2380E+03 0.3927E+06 U-234 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 055:

Pu-239 8

0.7594336440E+12 0.2390E+03 0.3558E+05 U-235 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 056:

Pu-240 8

0.2062920312E+12 0.2400E+03 0.5406E+05 U-236 0.1000E+01

Numerical Applications Inc. Attachment 2 Page 44 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 none 0.0000E+00 none 0.0000E+00 Nuclide 057:

Pu-241 8

0.4544294400E+09 0.2410E+03 0.1522E+08 U-237 0.2450E-04 Am-241 0.1000E+01 none 0.0000E+00 Nuclide 058:

Am-241 9

0.1363919472E+11 0.2410E+03 0.1884E+05 Np-237 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 059:

Cm-242 9

0.1406592000E+08 0.2420E+03 0.5669E+07 Pu-238 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 060:

Cm-244 9

0.5715081360E+09 0.2440E+03 0.5943E+06 Pu-240 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 061:

I-130 2

0.4449600000E+05 0.1300E+03 0.3743E+07 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 062:

Kr-83m 1

0.6588000000E+04 0.8300E+02 0.9119E+07 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 063:

Xe-138 1

0.8502000000E+03 0.1380E+03 0.1211E+09 Cs-138 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 064:

Xe-131m 1

0.1028160000E+07 0.1310E+03 0.8346E+06 none 0.0000E+00 none 0.0000E+00

Numerical Applications Inc. Attachment 2 Page 45 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 none 0.0000E+00 Nuclide 065:

Xe-133m 1

0.1890432000E+06 0.1330E+03 0.4659E+07 Xe-133 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 066:

Xe-135m 1

0.9174000000E+03 0.1350E+03 0.2999E+08 Xe-135 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 067:

Cs-138 3

0.1932000000E+04 0.1380E+03 0.1340E+09 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 068:

Cs-134m 3

0.1044000000E+05 0.1340E+03 0.4920E+07 Cs-134 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 069:

Rb-88 3

0.1068000000E+04 0.8800E+02 0.5369E+08 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 070:

Rb-89 3

0.9120000000E+03 0.8900E+02 0.6895E+08 Sr-89 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 071:

Sb-124 4

0.5201280000E+07 0.1240E+03 0.1702E+06 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 072:

Sb-125 4

0.8741455200E+08 0.1250E+03 0.1567E+07 Te-125m 0.2280E+00 none 0.0000E+00 none 0.0000E+00

Numerical Applications Inc. Attachment 2 Page 46 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Nuclide 073:

Sb-126 4

0.1071360000E+07 0.1260E+03 0.1107E+06 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 074:

Te-131 4

0.1500000000E+04 0.1310E+03 0.6601E+08 I-131 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 075:

Te-133 4

0.7470000000E+03 0.1330E+03 0.8639E+08 I-133 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 076:

Te-134 4

0.2508000000E+04 0.1340E+03 0.1220E+09 I-134 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 077:

Te-125m 4

0.5011200000E+07 0.1250E+03 0.3413E+06 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 078:

Te-133m 4

0.3324000000E+04 0.1330E+03 0.5406E+08 I-133 0.8700E+00 Te-133 0.1300E+00 none 0.0000E+00 Nuclide 079:

Ba-141 6

0.1096200000E+04 0.1410E+03 0.1188E+09 La-141 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 080:

Ba-137m 6

0.1531200000E+03 0.1370E+03 0.1043E+08 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 081:

Numerical Applications Inc. Attachment 2 Page 47 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Pd-109 7

0.4833720000E+05 0.1090E+03 0.3327E+08 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 082:

Rh-106 7

0.2990000000E+02 0.1060E+03 0.6285E+08 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 083:

Rh-103m 7

0.3367200000E+04 0.1030E+03 0.1135E+09 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 084:

Tc-101 7

0.8520000000E+03 0.1010E+03 0.1261E+09 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 085:

Eu-154 9

0.2777068800E+09 0.1540E+03 0.1247E+07 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 086:

Eu-155 9

0.1565256960E+09 0.1550E+03 0.8448E+06 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 087:

Eu-156 9

0.1312416000E+07 0.1560E+03 0.2023E+08 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 088:

La-143 9

0.8538000000E+03 0.1430E+03 0.1108E+09 Ce-143 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 089:

Nb-97

Numerical Applications Inc. Attachment 2 Page 48 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 9

0.4326000000E+04 0.9700E+02 0.1216E+09 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 090:

Nb-95m 9

0.3117600000E+06 0.9500E+02 0.8835E+06 Nb-95 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 091:

Pm-147 9

0.8278820780E+08 0.1470E+03 0.1292E+08 Sm-147 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 092:

Pm-148 9

0.4639680000E+06 0.1480E+03 0.2144E+08 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 093:

Pm-149 9

0.1910880000E+06 0.1490E+03 0.4541E+08 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 094:

Pm-151 9

0.1022400000E+06 0.1510E+03 0.1606E+08 Sm-151 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 095:

Pm-148m 9

0.3568320000E+07 0.1480E+03 0.2999E+07 Pm-148 0.4600E-01 none 0.0000E+00 none 0.0000E+00 Nuclide 096:

Pr-144 9

0.1036800000E+04 0.1440E+03 0.1025E+09 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 097:

Pr-144m 9

Numerical Applications Inc. Attachment 2 Page 49 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 0.4320000000E+03 0.1440E+03 0.1224E+07 Pr-144 0.9990E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 098:

Sm-153 9

0.1681200000E+06 0.1530E+03 0.4423E+08 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 099:

Y-94 9

0.1146000000E+04 0.9400E+02 0.1105E+09 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 100:

Y-95 9

0.6420000000E+03 0.9500E+02 0.1183E+09 Zr-95 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 101:

Y-91m 9

0.2982600000E+04 0.9100E+02 0.5151E+08 Y-91 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 102:

Br-82 2

0.1270800000E+06 0.8200E+02 0.5282E+06 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 103:

Br-83 2

0.8604000000E+04 0.8300E+02 0.9102E+07 Kr-83m 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 104:

Br-84 2

0.1908000000E+04 0.8400E+02 0.1591E+08 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 105:

Am-242 9

0.5767200000E+05

Numerical Applications Inc. Attachment 2 Page 50 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 0.2420E+03 0.9062E+07 Cm-242 0.8270E+00 Pu-242 0.1730E+00 none 0.0000E+00 Nuclide 106:

Np-238 8

0.1829088000E+06 0.2380E+03 0.4306E+08 Pu-238 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 107:

Pu-243 8

0.1784160000E+05 0.2430E+03 0.4690E+08 Am-243 0.1000E+01 none 0.0000E+00 none 0.0000E+00 End of Nuclear Inventory File

Numerical Applications Inc. Attachment 3 Page 51 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 RADTRAD-NAI Dose Conversion Factor File NAI-1101-001rev0.DCF Includes 107 istopes 9 ORGANS DEFINED IN THIS FILE:

GONADS BREAST LUNGS RED MARR BONE SUR THYROID REMAINDER EFFECTIVE SKIN(FGR) 107 NUCLIDES DEFINED IN THIS FILE:

Co-58 Y Co-60 Y Kr-85 Kr-85m Kr-87 Kr-88 Rb-86 D Sr-89 Y Sr-90 Y Sr-91 Y Sr-92 Y Y-90 Y Y-91 Y Y-92 Y Y-93 Y Zr-95 D Zr-97 Y Nb-95 Y Mo-99 Y Tc-99m D Ru-103 Y Ru-105 Y Ru-106 Y Rh-105 Y Sb-127 W Sb-129 W Te-127 W Te-127m W Te-129 D Te-129m W Te-131m W Te-132 W I-131 D I-132 D I-133 D I-134 D I-135 D Xe-133 Xe-135 Cs-134 D Cs-136 D Cs-137 D Ba-139 D Ba-140 D La-140 W La-141 D La-142 D Ce-141 Y Ce-143 Y Ce-144 Y Pr-143 Y Nd-147 Y Np-239 W Pu-238 W Pu-239 W Pu-240 W Pu-241 W Am-241 W

Numerical Applications Inc. Attachment 3 Page 52 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Cm-242 W Cm-244 W I-130 D Kr-83m Xe-138 Xe-131m Xe-133m Xe-135m Cs-138 D Cs-134m D Rb-88 D Rb-89 D Sb-124 W Sb-125 W Sb-126 W Te-131 D Te-133 D Te-134 D Te-125m W Te-133m D Ba-141 D Ba-137m Pd-109 Y Rh-106 Rh-103m D Tc-101 D Eu-154 W Eu-155 W Eu-156 W La-143 W Nb-97 Y Nb-95m Y Pm-147 Y Pm-148 Y Pm-149 Y Pm-151 Y Pm-148m Y Pr-144 Y Pr-144m Sm-153 W Y-94 Y Y-95 Y Y-91m Y Br-82 W Br-83 W Br-84 D Am-242 W Np-238 W Pu-243 Y CLOUDSHINE GROUND GROUND GROUND INHALED INHALED INGESTION SHINE 8HR SHINE 7DAY SHINE RATE ACUTE CHRONIC Co-58 GONADS 4.660E-14 2.867E-11 5.828E-10 9.970E-16-1.000E+00 6.170E-10 1.040E-09 BREAST 5.300E-14 2.737E-11 5.565E-10 9.520E-16-1.000E+00 9.370E-10 1.790E-10 LUNGS 4.640E-14 2.617E-11 5.319E-10 9.100E-16-1.000E+00 1.600E-08 8.530E-11 RED MARR 4.530E-14 2.671E-11 5.430E-10 9.290E-16-1.000E+00 9.230E-10 2.600E-10 BONE SUR 7.410E-14 3.795E-11 7.716E-10 1.320E-15-1.000E+00 6.930E-10 1.250E-10 THYROID 4.770E-14 2.720E-11 5.530E-10 9.460E-16-1.000E+00 8.720E-10 6.310E-11 REMAINDER 4.440E-14 2.585E-11 5.255E-10 8.990E-16-1.000E+00 1.890E-09 1.580E-09 EFFECTIVE 4.760E-14 2.732E-11 5.553E-10 9.500E-16-1.000E+00 2.940E-09 8.090E-10 SKIN(FGR) 5.580E-14 3.278E-11 6.664E-10 1.140E-15-1.000E+00 0.000E+00 0.000E+00 Co-60 GONADS 1.230E-13 7.056E-11 1.480E-09 2.450E-15-1.000E+00 4.760E-09 3.190E-09 BREAST 1.390E-13 6.739E-11 1.413E-09 2.340E-15-1.000E+00 1.840E-08 1.100E-09 LUNGS 1.240E-13 6.537E-11 1.371E-09 2.270E-15-1.000E+00 3.450E-07 8.770E-10 RED MARR 1.230E-13 6.710E-11 1.407E-09 2.330E-15-1.000E+00 1.720E-08 1.320E-09 BONE SUR 1.780E-13 8.956E-11 1.879E-09 3.110E-15-1.000E+00 1.350E-08 9.390E-10 THYROID 1.270E-13 6.480E-11 1.359E-09 2.250E-15-1.000E+00 1.620E-08 7.880E-10 REMAINDER 1.200E-13 6.508E-11 1.365E-09 2.260E-15-1.000E+00 3.600E-08 4.970E-09 EFFECTIVE 1.260E-13 6.768E-11 1.419E-09 2.350E-15-1.000E+00 5.910E-08 2.770E-09 SKIN(FGR) 1.450E-13 7.948E-11 1.667E-09 2.760E-15-1.000E+00 0.000E+00 0.000E+00 Kr-85 GONADS 1.170E-16 8.121E-14 1.704E-12 2.820E-18-1.000E+00 0.000E+00 0.000E+00

Numerical Applications Inc. Attachment 3 Page 53 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 BREAST 1.340E-16 7.891E-14 1.656E-12 2.740E-18-1.000E+00 0.000E+00 0.000E+00 LUNGS 1.140E-16 7.056E-14 1.481E-12 2.450E-18-1.000E+00 0.000E+00 0.000E+00 RED MARR 1.090E-16 6.998E-14 1.469E-12 2.430E-18-1.000E+00 0.000E+00 0.000E+00 BONE SUR 2.200E-16 1.287E-13 2.702E-12 4.470E-18-1.000E+00 0.000E+00 0.000E+00 THYROID 1.180E-16 7.459E-14 1.565E-12 2.590E-18-1.000E+00 0.000E+00 0.000E+00 REMAINDER 1.090E-16 6.941E-14 1.457E-12 2.410E-18-1.000E+00 0.000E+00 0.000E+00 EFFECTIVE 1.190E-16 7.603E-14 1.596E-12 2.640E-18-1.000E+00 0.000E+00 0.000E+00 SKIN(FGR) 1.320E-14 2.304E-11 4.835E-10 8.000E-16-1.000E+00 0.000E+00 0.000E+00 Kr-85m GONADS 7.310E-15 2.594E-12 3.653E-12 1.570E-16-1.000E+00 0.000E+00 0.000E+00 BREAST 8.410E-15 2.527E-12 3.560E-12 1.530E-16-1.000E+00 0.000E+00 0.000E+00 LUNGS 7.040E-15 2.379E-12 3.351E-12 1.440E-16-1.000E+00 0.000E+00 0.000E+00 RED MARR 6.430E-15 2.346E-12 3.304E-12 1.420E-16-1.000E+00 0.000E+00 0.000E+00 BONE SUR 1.880E-14 5.286E-12 7.446E-12 3.200E-16-1.000E+00 0.000E+00 0.000E+00 THYROID 7.330E-15 2.395E-12 3.374E-12 1.450E-16-1.000E+00 0.000E+00 0.000E+00 REMAINDER 6.640E-15 2.313E-12 3.257E-12 1.400E-16-1.000E+00 0.000E+00 0.000E+00 EFFECTIVE 7.480E-15 2.511E-12 3.537E-12 1.520E-16-1.000E+00 0.000E+00 0.000E+00 SKIN(FGR) 2.240E-14 2.247E-11 3.164E-11 1.360E-15-1.000E+00 0.000E+00 0.000E+00 Kr-87 GONADS 4.000E-14 4.962E-12 5.026E-12 7.610E-16-1.000E+00 0.000E+00 0.000E+00 BREAST 4.500E-14 4.740E-12 4.802E-12 7.270E-16-1.000E+00 0.000E+00 0.000E+00 LUNGS 4.040E-14 4.603E-12 4.663E-12 7.060E-16-1.000E+00 0.000E+00 0.000E+00 RED MARR 4.000E-14 4.708E-12 4.769E-12 7.220E-16-1.000E+00 0.000E+00 0.000E+00 BONE SUR 6.020E-14 6.514E-12 6.598E-12 9.990E-16-1.000E+00 0.000E+00 0.000E+00 THYROID 4.130E-14 4.473E-12 4.531E-12 6.860E-16-1.000E+00 0.000E+00 0.000E+00 REMAINDER 3.910E-14 4.590E-12 4.650E-12 7.040E-16-1.000E+00 0.000E+00 0.000E+00 EFFECTIVE 4.120E-14 4.773E-12 4.835E-12 7.320E-16-1.000E+00 0.000E+00 0.000E+00 SKIN(FGR) 1.370E-13 8.802E-11 8.916E-11 1.350E-14-1.000E+00 0.000E+00 0.000E+00 Kr-88 GONADS 9.900E-14 2.278E-11 2.655E-11 1.800E-15-1.000E+00 0.000E+00 0.000E+00 BREAST 1.110E-13 2.177E-11 2.537E-11 1.720E-15-1.000E+00 0.000E+00 0.000E+00 LUNGS 1.010E-13 2.139E-11 2.493E-11 1.690E-15-1.000E+00 0.000E+00 0.000E+00 RED MARR 1.000E-13 2.190E-11 2.552E-11 1.730E-15-1.000E+00 0.000E+00 0.000E+00 BONE SUR 1.390E-13 2.886E-11 3.363E-11 2.280E-15-1.000E+00 0.000E+00 0.000E+00 THYROID 1.030E-13 2.012E-11 2.345E-11 1.590E-15-1.000E+00 0.000E+00 0.000E+00 REMAINDER 9.790E-14 2.139E-11 2.493E-11 1.690E-15-1.000E+00 0.000E+00 0.000E+00 EFFECTIVE 1.020E-13 2.202E-11 2.567E-11 1.740E-15-1.000E+00 0.000E+00 0.000E+00 SKIN(FGR) 1.350E-13 5.607E-11 6.534E-11 4.430E-15-1.000E+00 0.000E+00 0.000E+00 Rb-86 GONADS 4.710E-15 2.788E-12 5.187E-11 9.740E-17-1.000E+00 1.340E-09 2.150E-09 BREAST 5.340E-15 2.662E-12 4.953E-11 9.300E-17-1.000E+00 1.330E-09 2.140E-09 LUNGS 4.710E-15 2.553E-12 4.750E-11 8.920E-17-1.000E+00 3.300E-09 2.140E-09 RED MARR 4.640E-15 2.619E-12 4.873E-11 9.150E-17-1.000E+00 2.320E-09 3.720E-09 BONE SUR 7.050E-15 3.635E-12 6.764E-11 1.270E-16-1.000E+00 4.270E-09 6.860E-09 THYROID 4.840E-15 2.599E-12 4.836E-11 9.080E-17-1.000E+00 1.330E-09 2.140E-09 REMAINDER 4.520E-15 2.542E-12 4.729E-11 8.880E-17-1.000E+00 1.380E-09 2.330E-09 EFFECTIVE 4.810E-15 2.665E-12 4.958E-11 9.310E-17-1.000E+00 1.790E-09 2.530E-09 SKIN(FGR) 4.850E-14 2.210E-10 4.111E-09 7.720E-15-1.000E+00 0.000E+00 0.000E+00 Sr-89 GONADS 7.730E-17 7.155E-14 1.436E-12 2.490E-18-1.000E+00 7.950E-12 8.050E-12 BREAST 9.080E-17 7.212E-14 1.447E-12 2.510E-18-1.000E+00 7.960E-12 7.980E-12 LUNGS 7.080E-17 5.689E-14 1.142E-12 1.980E-18-1.000E+00 8.350E-08 7.970E-12 RED MARR 6.390E-17 5.345E-14 1.073E-12 1.860E-18-1.000E+00 1.070E-10 1.080E-10 BONE SUR 1.940E-16 1.560E-13 3.131E-12 5.430E-18-1.000E+00 1.590E-10 1.610E-10 THYROID 7.600E-17 6.063E-14 1.217E-12 2.110E-18-1.000E+00 7.960E-12 7.970E-12 REMAINDER 6.710E-17 5.603E-14 1.124E-12 1.950E-18-1.000E+00 3.970E-09 8.250E-09 EFFECTIVE 7.730E-17 6.523E-14 1.309E-12 2.270E-18-1.000E+00 1.120E-08 2.500E-09 SKIN(FGR) 3.690E-14 1.914E-10 3.841E-09 6.660E-15-1.000E+00 0.000E+00 0.000E+00 Sr-90 GONADS 7.780E-18 9.590E-15 2.014E-13 3.330E-19-1.000E+00 2.690E-10 5.040E-11 BREAST 9.490E-18 1.008E-14 2.116E-13 3.500E-19-1.000E+00 2.690E-10 5.040E-11 LUNGS 6.440E-18 6.307E-15 1.324E-13 2.190E-19-1.000E+00 2.860E-06 5.040E-11 RED MARR 5.440E-18 5.558E-15 1.167E-13 1.930E-19-1.000E+00 3.280E-08 6.450E-09 BONE SUR 2.280E-17 2.393E-14 5.025E-13 8.310E-19-1.000E+00 7.090E-08 1.390E-08 THYROID 7.330E-18 7.171E-15 1.506E-13 2.490E-19-1.000E+00 2.690E-10 5.040E-11 REMAINDER 6.110E-18 6.422E-15 1.348E-13 2.230E-19-1.000E+00 5.730E-09 6.700E-09 EFFECTIVE 7.530E-18 8.179E-15 1.717E-13 2.840E-19-1.000E+00 3.510E-07 3.230E-09 SKIN(FGR) 9.200E-15 4.032E-12 8.465E-11 1.400E-16-1.000E+00 0.000E+00 0.000E+00 Sr-91 GONADS 3.380E-14 2.155E-11 5.062E-11 1.026E-15-1.000E+00 5.650E-11 2.520E-10 BREAST 3.830E-14 2.059E-11 4.838E-11 9.806E-16-1.000E+00 1.740E-11 3.676E-11 LUNGS 3.370E-14 1.970E-11 4.626E-11 9.376E-16-1.000E+00 2.130E-09 1.055E-11 RED MARR 3.310E-14 2.011E-11 4.722E-11 9.570E-16-1.000E+00 2.230E-11 5.659E-11

Numerical Applications Inc. Attachment 3 Page 54 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 BONE SUR 5.200E-14 2.852E-11 6.709E-11 1.360E-15-1.000E+00 1.270E-11 2.070E-11 THYROID 3.470E-14 2.035E-11 4.782E-11 9.693E-16-1.000E+00 9.640E-12 1.968E-12 REMAINDER 3.240E-14 1.948E-11 4.573E-11 9.268E-16-1.000E+00 5.780E-10 2.557E-09 EFFECTIVE 3.450E-14 2.057E-11 4.832E-11 9.793E-16-1.000E+00 4.490E-10 8.455E-10 SKIN(FGR) 8.140E-14 1.748E-10 3.987E-10 8.080E-15-1.000E+00 0.000E+00 0.000E+00 Sr-92 GONADS 6.610E-14 1.593E-11 1.830E-11 1.300E-15-1.000E+00 1.020E-11 8.180E-11 BREAST 7.480E-14 1.520E-11 1.745E-11 1.240E-15-1.000E+00 6.490E-12 1.700E-11 LUNGS 6.670E-14 1.483E-11 1.703E-11 1.210E-15-1.000E+00 1.050E-09 7.220E-12 RED MARR 6.620E-14 1.520E-11 1.745E-11 1.240E-15-1.000E+00 6.980E-12 2.290E-11 BONE SUR 9.490E-14 2.010E-11 2.308E-11 1.640E-15-1.000E+00 4.360E-12 8.490E-12 THYROID 6.820E-14 1.446E-11 1.661E-11 1.180E-15-1.000E+00 3.920E-12 1.300E-12 REMAINDER 6.450E-14 1.471E-11 1.689E-11 1.200E-15-1.000E+00 2.900E-10 1.720E-09 EFFECTIVE 6.790E-14 1.532E-11 1.759E-11 1.250E-15-1.000E+00 2.180E-10 5.430E-10 SKIN(FGR) 8.560E-14 2.280E-11 2.618E-11 1.860E-15-1.000E+00 0.000E+00 0.000E+00 Y-90 GONADS 1.890E-16 1.586E-13 1.601E-12 5.750E-18-1.000E+00 5.170E-13 1.430E-14 BREAST 2.200E-16 1.578E-13 1.593E-12 5.720E-18-1.000E+00 5.170E-13 1.270E-14 LUNGS 1.770E-16 1.313E-13 1.326E-12 4.760E-18-1.000E+00 9.310E-09 1.260E-14 RED MARR 1.620E-16 1.261E-13 1.273E-12 4.570E-18-1.000E+00 1.520E-11 3.700E-13 BONE SUR 4.440E-16 3.228E-13 3.259E-12 1.170E-17-1.000E+00 1.510E-11 3.670E-13 THYROID 1.870E-16 1.385E-13 1.398E-12 5.020E-18-1.000E+00 5.170E-13 1.260E-14 REMAINDER 1.680E-16 1.291E-13 1.303E-12 4.680E-18-1.000E+00 3.870E-09 9.680E-09 EFFECTIVE 1.900E-16 1.468E-13 1.482E-12 5.320E-18-1.000E+00 2.280E-09 2.910E-09 SKIN(FGR) 6.240E-14 2.897E-10 2.924E-09 1.050E-14-1.000E+00 0.000E+00 0.000E+00 Y-91 GONADS 2.560E-16 1.756E-13 3.546E-12 6.110E-18-1.000E+00 8.200E-12 3.540E-12 BREAST 2.930E-16 1.713E-13 3.459E-12 5.960E-18-1.000E+00 8.920E-12 5.540E-13 LUNGS 2.500E-16 1.526E-13 3.082E-12 5.310E-18-1.000E+00 9.870E-08 2.020E-13 RED MARR 2.410E-16 1.521E-13 3.070E-12 5.290E-18-1.000E+00 3.190E-10 6.590E-12 BONE SUR 4.560E-16 2.903E-13 5.862E-12 1.010E-17-1.000E+00 3.180E-10 6.130E-12 THYROID 2.600E-16 1.564E-13 3.157E-12 5.440E-18-1.000E+00 8.500E-12 1.290E-13 REMAINDER 2.390E-16 1.509E-13 3.047E-12 5.250E-18-1.000E+00 4.200E-09 8.570E-09 EFFECTIVE 2.600E-16 1.650E-13 3.332E-12 5.740E-18-1.000E+00 1.320E-08 2.570E-09 SKIN(FGR) 3.850E-14 1.989E-10 4.016E-09 6.920E-15-1.000E+00 0.000E+00 0.000E+00 Y-92 GONADS 1.270E-14 3.855E-12 4.872E-12 2.650E-16-1.000E+00 2.610E-12 1.960E-11 BREAST 1.440E-14 3.680E-12 4.652E-12 2.530E-16-1.000E+00 1.500E-12 3.550E-12 LUNGS 1.270E-14 3.535E-12 4.468E-12 2.430E-16-1.000E+00 1.240E-09 1.390E-12 RED MARR 1.250E-14 3.608E-12 4.560E-12 2.480E-16-1.000E+00 2.070E-12 4.910E-12 BONE SUR 1.950E-14 5.091E-12 6.435E-12 3.500E-16-1.000E+00 1.510E-12 1.750E-12 THYROID 1.300E-14 3.579E-12 4.523E-12 2.460E-16-1.000E+00 1.050E-12 1.770E-13 REMAINDER 1.220E-14 3.506E-12 4.431E-12 2.410E-16-1.000E+00 2.030E-10 1.700E-09 EFFECTIVE 1.300E-14 3.680E-12 4.652E-12 2.530E-16-1.000E+00 2.110E-10 5.150E-10 SKIN(FGR) 1.140E-13 2.022E-10 2.556E-10 1.390E-14-1.000E+00 0.000E+00 0.000E+00 Y-93 GONADS 4.670E-15 2.108E-12 4.989E-12 9.510E-17-1.000E+00 5.310E-12 2.200E-11 BREAST 5.300E-15 2.026E-12 4.794E-12 9.140E-17-1.000E+00 1.740E-12 3.130E-12 LUNGS 4.680E-15 1.937E-12 4.585E-12 8.740E-17-1.000E+00 2.520E-09 8.670E-13 RED MARR 4.580E-15 1.972E-12 4.669E-12 8.900E-17-1.000E+00 4.040E-12 4.930E-12 BONE SUR 7.580E-15 2.948E-12 6.977E-12 1.330E-16-1.000E+00 3.140E-12 1.730E-12 THYROID 4.790E-15 1.908E-12 4.516E-12 8.610E-17-1.000E+00 9.260E-13 1.260E-13 REMAINDER 4.510E-15 1.919E-12 4.543E-12 8.660E-17-1.000E+00 9.250E-10 4.090E-09 EFFECTIVE 4.800E-15 2.021E-12 4.784E-12 9.120E-17-1.000E+00 5.820E-10 1.230E-09 SKIN(FGR) 8.500E-14 2.726E-10 6.452E-10 1.230E-14-1.000E+00 0.000E+00 0.000E+00 Zr-95 GONADS 3.530E-14 2.182E-11 4.421E-10 7.590E-16-1.000E+00 1.880E-09 8.160E-10 BREAST 4.010E-14 2.084E-11 4.223E-10 7.250E-16-1.000E+00 1.910E-09 1.050E-10 LUNGS 3.510E-14 1.989E-11 4.030E-10 6.920E-16-1.000E+00 2.170E-09 2.340E-11 RED MARR 3.430E-14 2.030E-11 4.112E-10 7.060E-16-1.000E+00 1.300E-08 2.140E-10 BONE SUR 5.620E-14 2.875E-11 5.824E-10 1.000E-15-1.000E+00 1.030E-07 4.860E-10 THYROID 3.610E-14 2.076E-11 4.205E-10 7.220E-16-1.000E+00 1.440E-09 8.270E-12 REMAINDER 3.360E-14 1.963E-11 3.978E-10 6.830E-16-1.000E+00 2.280E-09 2.530E-09 EFFECTIVE 3.600E-14 2.078E-11 4.211E-10 7.230E-16-1.000E+00 6.390E-09 1.020E-09 SKIN(FGR) 4.500E-14 2.561E-11 5.190E-10 8.910E-16-1.000E+00 0.000E+00 0.000E+00 Zr-97 GONADS 8.800E-15 2.179E-11 7.799E-11 9.253E-16-1.000E+00 1.840E-10 6.228E-10 BREAST 9.990E-15 2.083E-11 7.455E-11 8.846E-16-1.000E+00 4.700E-11 8.137E-11 LUNGS 8.810E-15 1.992E-11 7.127E-11 8.456E-16-1.000E+00 4.100E-09 1.770E-11 RED MARR 8.640E-15 2.034E-11 7.279E-11 8.634E-16-1.000E+00 6.370E-11 1.302E-10 BONE SUR 1.380E-14 2.881E-11 1.031E-10 1.224E-15-1.000E+00 3.500E-11 4.558E-11 THYROID 9.030E-15 2.061E-11 7.377E-11 8.755E-16-1.000E+00 2.310E-11 2.671E-12 REMAINDER 8.480E-15 1.966E-11 7.035E-11 8.345E-16-1.000E+00 2.040E-09 6.990E-09

Numerical Applications Inc. Attachment 3 Page 55 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 EFFECTIVE 9.020E-15 2.078E-11 7.438E-11 8.824E-16-1.000E+00 1.170E-09 2.283E-09 SKIN(FGR) 5.550E-14 2.281E-10 8.148E-10 9.587E-15-1.000E+00 0.000E+00 0.000E+00 Nb-95 GONADS 3.660E-14 2.253E-11 4.435E-10 7.850E-16-1.000E+00 4.320E-10 8.050E-10 BREAST 4.160E-14 2.150E-11 4.231E-10 7.490E-16-1.000E+00 4.070E-10 1.070E-10 LUNGS 3.650E-14 2.055E-11 4.045E-10 7.160E-16-1.000E+00 8.320E-09 2.740E-11 RED MARR 3.560E-14 2.101E-11 4.135E-10 7.320E-16-1.000E+00 4.420E-10 1.990E-10 BONE SUR 5.790E-14 2.957E-11 5.819E-10 1.030E-15-1.000E+00 5.130E-10 2.940E-10 THYROID 3.750E-14 2.144E-11 4.220E-10 7.470E-16-1.000E+00 3.580E-10 1.180E-11 REMAINDER 3.490E-14 2.032E-11 4.000E-10 7.080E-16-1.000E+00 1.070E-09 1.470E-09 EFFECTIVE 3.740E-14 2.147E-11 4.226E-10 7.480E-16-1.000E+00 1.570E-09 6.950E-10 SKIN(FGR) 4.300E-14 2.598E-11 5.112E-10 9.050E-16-1.000E+00 0.000E+00 0.000E+00 Mo-99 GONADS 7.130E-15 4.282E-12 4.403E-11 1.550E-16-1.000E+00 9.510E-11 2.180E-10 BREAST 8.130E-15 4.116E-12 4.233E-11 1.490E-16-1.000E+00 2.750E-11 3.430E-11 LUNGS 7.060E-15 3.867E-12 3.977E-11 1.400E-16-1.000E+00 4.290E-09 1.510E-11 RED MARR 6.820E-15 3.923E-12 4.034E-11 1.420E-16-1.000E+00 5.240E-11 8.320E-11 BONE SUR 1.240E-14 6.105E-12 6.278E-11 2.210E-16-1.000E+00 4.130E-11 6.320E-11 THYROID 7.270E-15 4.033E-12 4.147E-11 1.460E-16-1.000E+00 1.520E-11 1.030E-11 REMAINDER 6.740E-15 3.812E-12 3.920E-11 1.380E-16-1.000E+00 1.740E-09 4.280E-09 EFFECTIVE 7.280E-15 4.061E-12 4.176E-11 1.470E-16-1.000E+00 1.070E-09 1.360E-09 SKIN(FGR) 3.140E-14 1.039E-10 1.068E-09 3.760E-15-1.000E+00 0.000E+00 0.000E+00 Tc-99m GONADS 5.750E-15 2.334E-12 3.877E-12 1.240E-16-1.000E+00 2.770E-12 9.750E-12 BREAST 6.650E-15 2.258E-12 3.752E-12 1.200E-16-1.000E+00 2.150E-12 3.570E-12 LUNGS 5.490E-15 2.127E-12 3.533E-12 1.130E-16-1.000E+00 2.280E-11 3.140E-12 RED MARR 4.910E-15 2.070E-12 3.439E-12 1.100E-16-1.000E+00 3.360E-12 6.290E-12 BONE SUR 1.630E-14 5.383E-12 8.942E-12 2.860E-16-1.000E+00 2.620E-12 4.060E-12 THYROID 5.750E-15 2.145E-12 3.564E-12 1.140E-16-1.000E+00 5.010E-11 8.460E-11 REMAINDER 5.150E-15 2.070E-12 3.439E-12 1.100E-16-1.000E+00 1.020E-11 3.340E-11 EFFECTIVE 5.890E-15 2.277E-12 3.783E-12 1.210E-16-1.000E+00 8.800E-12 1.680E-11 SKIN(FGR) 7.140E-15 2.710E-12 4.502E-12 1.440E-16-1.000E+00 0.000E+00 0.000E+00 Ru-103 GONADS 2.190E-14 1.404E-11 2.783E-10 4.892E-16-1.000E+00 3.070E-10 5.720E-10 BREAST 2.510E-14 1.350E-11 2.677E-10 4.705E-16-1.000E+00 3.110E-10 1.200E-10 LUNGS 2.180E-14 1.273E-11 2.522E-10 4.432E-16-1.000E+00 1.560E-08 7.310E-11 RED MARR 2.100E-14 1.287E-11 2.551E-10 4.483E-16-1.000E+00 3.190E-10 1.660E-10 BONE SUR 3.890E-14 1.958E-11 3.882E-10 6.823E-16-1.000E+00 2.370E-10 9.631E-11 THYROID 2.240E-14 1.331E-11 2.639E-10 4.638E-16-1.000E+00 2.570E-10 6.250E-11 REMAINDER 2.080E-14 1.248E-11 2.472E-10 4.346E-16-1.000E+00 1.250E-09 2.110E-09 EFFECTIVE 2.250E-14 1.332E-11 2.641E-10 4.642E-16-1.000E+00 2.420E-09 8.271E-10 SKIN(FGR) 2.770E-14 1.785E-11 3.543E-10 6.229E-16-1.000E+00 0.000E+00 0.000E+00 Ru-105 GONADS 3.720E-14 1.327E-11 1.861E-11 8.070E-16-1.000E+00 1.590E-11 9.670E-11 BREAST 4.240E-14 1.271E-11 1.783E-11 7.730E-16-1.000E+00 6.610E-12 1.590E-11 LUNGS 3.700E-14 1.210E-11 1.697E-11 7.360E-16-1.000E+00 5.730E-10 6.210E-12 RED MARR 3.590E-14 1.230E-11 1.725E-11 7.480E-16-1.000E+00 7.700E-12 2.350E-11 BONE SUR 6.280E-14 1.809E-11 2.537E-11 1.100E-15-1.000E+00 4.620E-12 8.890E-12 THYROID 3.800E-14 1.260E-11 1.766E-11 7.660E-16-1.000E+00 4.150E-12 1.820E-12 REMAINDER 3.540E-14 1.189E-11 1.667E-11 7.230E-16-1.000E+00 1.610E-10 8.540E-10 EFFECTIVE 3.810E-14 1.265E-11 1.773E-11 7.690E-16-1.000E+00 1.230E-10 2.870E-10 SKIN(FGR) 6.730E-14 7.368E-11 1.033E-10 4.480E-15-1.000E+00 0.000E+00 0.000E+00 Ru-106 GONADS 0.000E+00 6.411E-12 1.340E-10 2.230E-16-1.000E+00 1.300E-09 1.640E-09 BREAST 0.000E+00 6.152E-12 1.286E-10 2.140E-16-1.000E+00 1.780E-09 1.440E-09 LUNGS 0.000E+00 5.836E-12 1.220E-10 2.030E-16-1.000E+00 1.040E-06 1.420E-09 RED MARR 0.000E+00 5.893E-12 1.232E-10 2.050E-16-1.000E+00 1.760E-09 1.460E-09 BONE SUR 0.000E+00 8.883E-12 1.856E-10 3.090E-16-1.000E+00 1.610E-09 1.430E-09 THYROID 0.000E+00 6.066E-12 1.268E-10 2.110E-16-1.000E+00 1.720E-09 1.410E-09 REMAINDER 0.000E+00 5.721E-12 1.196E-10 1.990E-16-1.000E+00 1.200E-08 2.110E-08 EFFECTIVE 0.000E+00 6.095E-12 1.274E-10 2.120E-16-1.000E+00 1.290E-07 7.400E-09 SKIN(FGR) 0.000E+00 4.082E-10 8.531E-09 1.420E-14-1.000E+00 0.000E+00 0.000E+00 Rh-105 GONADS 3.640E-15 2.127E-12 1.411E-11 7.980E-17-1.000E+00 2.110E-11 5.800E-11 BREAST 4.160E-15 2.063E-12 1.369E-11 7.740E-17-1.000E+00 5.610E-12 8.970E-12 LUNGS 3.570E-15 1.935E-12 1.284E-11 7.260E-17-1.000E+00 9.580E-10 3.860E-12 RED MARR 3.380E-15 1.946E-12 1.291E-11 7.300E-17-1.000E+00 7.770E-12 1.470E-11 BONE SUR 7.530E-15 3.332E-12 2.210E-11 1.250E-16-1.000E+00 4.460E-12 6.750E-12 THYROID 3.680E-15 1.983E-12 1.316E-11 7.440E-17-1.000E+00 2.880E-12 2.910E-12 REMAINDER 3.390E-15 1.885E-12 1.250E-11 7.070E-17-1.000E+00 4.530E-10 1.270E-09 EFFECTIVE 3.720E-15 2.031E-12 1.347E-11 7.620E-17-1.000E+00 2.580E-10 3.990E-10 SKIN(FGR) 1.070E-14 4.691E-12 3.112E-11 1.760E-16-1.000E+00 0.000E+00 0.000E+00 Sb-127

Numerical Applications Inc. Attachment 3 Page 56 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 GONADS 3.260E-14 1.985E-11 2.441E-10 7.100E-16-1.000E+00 2.520E-10 6.140E-10 BREAST 3.720E-14 1.904E-11 2.341E-10 6.810E-16-1.000E+00 9.120E-11 7.600E-11 LUNGS 3.240E-14 1.809E-11 2.224E-10 6.470E-16-1.000E+00 6.940E-09 1.570E-11 RED MARR 3.140E-14 1.834E-11 2.255E-10 6.560E-16-1.000E+00 1.610E-10 1.330E-10 BONE SUR 5.520E-14 2.720E-11 3.345E-10 9.730E-16-1.000E+00 1.340E-10 5.240E-11 THYROID 3.330E-14 1.884E-11 2.317E-10 6.740E-16-1.000E+00 6.150E-11 4.640E-12 REMAINDER 3.090E-14 1.775E-11 2.183E-10 6.350E-16-1.000E+00 2.330E-09 5.870E-09 EFFECTIVE 3.330E-14 1.890E-11 2.324E-10 6.760E-16-1.000E+00 1.630E-09 1.950E-09 SKIN(FGR) 5.580E-14 7.967E-11 9.799E-10 2.850E-15-1.000E+00 0.000E+00 0.000E+00 Sb-129 GONADS 6.970E-14 2.336E-11 3.231E-11 1.440E-15-1.000E+00 2.150E-11 1.510E-10 BREAST 7.910E-14 2.222E-11 3.074E-11 1.370E-15-1.000E+00 1.280E-11 2.560E-11 LUNGS 6.980E-14 2.141E-11 2.962E-11 1.320E-15-1.000E+00 8.980E-10 9.390E-12 RED MARR 6.860E-14 2.190E-11 3.029E-11 1.350E-15-1.000E+00 1.700E-11 3.670E-11 BONE SUR 1.070E-13 3.033E-11 4.196E-11 1.870E-15-1.000E+00 1.460E-11 1.340E-11 THYROID 7.160E-14 2.174E-11 3.007E-11 1.340E-15-1.000E+00 9.720E-12 1.470E-12 REMAINDER 6.710E-14 2.125E-11 2.939E-11 1.310E-15-1.000E+00 1.870E-10 1.450E-09 EFFECTIVE 7.140E-14 2.238E-11 3.096E-11 1.380E-15-1.000E+00 1.740E-10 4.840E-10 SKIN(FGR) 1.050E-13 8.273E-11 1.144E-10 5.100E-15-1.000E+00 0.000E+00 0.000E+00 Te-127 GONADS 2.370E-16 1.191E-13 2.661E-13 5.480E-18-1.000E+00 2.020E-12 4.020E-12 BREAST 2.730E-16 1.158E-13 2.588E-13 5.330E-18-1.000E+00 1.880E-12 3.000E-12 LUNGS 2.320E-16 1.060E-13 2.370E-13 4.880E-18-1.000E+00 4.270E-10 2.890E-12 RED MARR 2.210E-16 1.058E-13 2.365E-13 4.870E-18-1.000E+00 4.090E-12 6.570E-12 BONE SUR 4.650E-16 1.862E-13 4.162E-13 8.570E-18-1.000E+00 4.090E-12 6.460E-12 THYROID 2.400E-16 1.106E-13 2.472E-13 5.090E-18-1.000E+00 1.840E-12 2.860E-12 REMAINDER 2.210E-16 1.036E-13 2.316E-13 4.770E-18-1.000E+00 1.110E-10 6.130E-10 EFFECTIVE 2.420E-16 1.125E-13 2.515E-13 5.180E-18-1.000E+00 8.600E-11 1.870E-10 SKIN(FGR) 1.140E-14 1.173E-11 2.622E-11 5.400E-16-1.000E+00 0.000E+00 0.000E+00 Te-127m GONADS 1.900E-16 4.689E-13 9.642E-12 1.630E-17-1.000E+00 1.100E-10 1.250E-10 BREAST 2.690E-16 5.150E-13 1.059E-11 1.790E-17-1.000E+00 1.100E-10 9.740E-11 LUNGS 7.620E-17 1.602E-13 3.295E-12 5.570E-18-1.000E+00 3.340E-08 9.620E-11 RED MARR 6.430E-17 1.249E-13 2.567E-12 4.340E-18-1.000E+00 5.360E-09 5.430E-09 BONE SUR 3.940E-16 9.005E-13 1.852E-11 3.130E-17-1.000E+00 2.040E-08 2.070E-08 THYROID 1.500E-16 2.779E-13 5.714E-12 9.660E-18-1.000E+00 9.660E-11 9.430E-11 REMAINDER 8.640E-17 1.999E-13 4.111E-12 6.950E-18-1.000E+00 1.660E-09 2.980E-09 EFFECTIVE 1.470E-16 3.251E-13 6.684E-12 1.130E-17-1.000E+00 5.810E-09 2.230E-09 SKIN(FGR) 8.490E-16 1.496E-12 3.076E-11 5.200E-17-1.000E+00 0.000E+00 0.000E+00 Te-129 GONADS 2.710E-15 3.889E-13 3.922E-13 6.510E-17-1.000E+00 1.750E-12 1.590E-12 BREAST 3.120E-15 3.800E-13 3.832E-13 6.360E-17-1.000E+00 1.680E-12 6.050E-13 LUNGS 2.640E-15 3.298E-13 3.326E-13 5.520E-17-1.000E+00 1.330E-10 4.910E-13 RED MARR 2.540E-15 3.298E-13 3.326E-13 5.520E-17-1.000E+00 1.970E-12 7.640E-13 BONE SUR 4.880E-15 5.753E-13 5.802E-13 9.630E-17-1.000E+00 2.030E-12 5.400E-13 THYROID 2.740E-15 3.525E-13 3.555E-13 5.900E-17-1.000E+00 1.630E-12 3.360E-13 REMAINDER 2.520E-15 3.262E-13 3.289E-13 5.460E-17-1.000E+00 2.400E-11 1.790E-10 EFFECTIVE 2.750E-15 3.590E-13 3.621E-13 6.010E-17-1.000E+00 2.420E-11 5.450E-11 SKIN(FGR) 3.570E-14 3.429E-11 3.458E-11 5.740E-15-1.000E+00 0.000E+00 0.000E+00 Te-129m GONADS 1.560E-15 2.206E-12 4.799E-11 8.561E-17-1.000E+00 1.780E-10 2.420E-10 BREAST 1.810E-15 2.181E-12 4.739E-11 8.454E-17-1.000E+00 1.690E-10 1.664E-10 LUNGS 1.460E-15 1.741E-12 3.815E-11 6.808E-17-1.000E+00 4.030E-08 1.593E-10 RED MARR 1.420E-15 1.729E-12 3.793E-11 6.768E-17-1.000E+00 3.100E-09 3.500E-09 BONE SUR 2.600E-15 3.287E-12 7.147E-11 1.275E-16-1.000E+00 7.050E-09 7.990E-09 THYROID 1.560E-15 1.923E-12 4.201E-11 7.495E-17-1.000E+00 1.560E-10 1.572E-10 REMAINDER 1.410E-15 1.746E-12 3.822E-11 6.819E-17-1.000E+00 3.270E-09 7.196E-09 EFFECTIVE 1.550E-15 1.974E-12 4.308E-11 7.686E-17-1.000E+00 6.470E-09 2.925E-09 SKIN(FGR) 1.490E-14 1.501E-10 3.360E-09 6.001E-15-1.000E+00 0.000E+00 0.000E+00 Te-131m GONADS 6.850E-14 4.020E-11 2.343E-10 1.535E-15-1.000E+00 2.340E-10 7.415E-10 BREAST 7.780E-14 3.853E-11 2.246E-10 1.472E-15-1.000E+00 9.250E-11 1.361E-10 LUNGS 6.830E-14 3.657E-11 2.131E-10 1.397E-15-1.000E+00 2.230E-09 6.335E-11 RED MARR 6.680E-14 3.736E-11 2.178E-10 1.427E-15-1.000E+00 1.410E-10 2.435E-10 BONE SUR 1.090E-13 5.467E-11 3.189E-10 2.090E-15-1.000E+00 2.270E-10 3.248E-10 THYROID 7.020E-14 3.741E-11 2.181E-10 1.429E-15-1.000E+00 3.610E-08 4.383E-08 REMAINDER 6.550E-14 3.626E-11 2.113E-10 1.385E-15-1.000E+00 9.460E-10 3.153E-09 EFFECTIVE 7.010E-14 3.825E-11 2.229E-10 1.461E-15-1.000E+00 1.730E-09 2.514E-09 SKIN(FGR) 8.850E-14 1.033E-10 6.188E-10 4.056E-15-1.000E+00 0.000E+00 0.000E+00 Te-132 GONADS 1.020E-14 6.812E-12 7.706E-11 2.450E-16-1.000E+00 4.150E-10 5.410E-10 BREAST 1.180E-14 6.756E-12 7.643E-11 2.430E-16-1.000E+00 3.630E-10 3.500E-10 LUNGS 9.650E-15 5.727E-12 6.479E-11 2.060E-16-1.000E+00 1.670E-09 3.300E-10

Numerical Applications Inc. Attachment 3 Page 57 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 RED MARR 8.950E-15 5.588E-12 6.322E-11 2.010E-16-1.000E+00 4.270E-10 4.440E-10 BONE SUR 2.420E-14 1.273E-11 1.441E-10 4.580E-16-1.000E+00 7.120E-10 8.300E-10 THYROID 1.020E-14 5.978E-12 6.762E-11 2.150E-16-1.000E+00 6.280E-08 5.950E-08 REMAINDER 9.160E-15 5.644E-12 6.385E-11 2.030E-16-1.000E+00 7.890E-10 1.490E-09 EFFECTIVE 1.030E-14 6.339E-12 7.171E-11 2.280E-16-1.000E+00 2.550E-09 2.540E-09 SKIN(FGR) 1.390E-14 8.313E-12 9.405E-11 2.990E-16-1.000E+00 0.000E+00 0.000E+00 I-131 GONADS 1.780E-14 1.119E-11 1.789E-10 3.940E-16-1.000E+00 2.530E-11 4.070E-11 BREAST 2.040E-14 1.082E-11 1.730E-10 3.810E-16-1.000E+00 7.880E-11 1.210E-10 LUNGS 1.760E-14 1.016E-11 1.626E-10 3.580E-16-1.000E+00 6.570E-10 1.020E-10 RED MARR 1.680E-14 1.022E-11 1.635E-10 3.600E-16-1.000E+00 6.260E-11 9.440E-11 BONE SUR 3.450E-14 1.675E-11 2.679E-10 5.900E-16-1.000E+00 5.730E-11 8.720E-11 THYROID 1.810E-14 1.053E-11 1.685E-10 3.710E-16-1.000E+00 2.920E-07 4.760E-07 REMAINDER 1.670E-14 9.908E-12 1.585E-10 3.490E-16-1.000E+00 8.030E-11 1.570E-10 EFFECTIVE 1.820E-14 1.067E-11 1.707E-10 3.760E-16-1.000E+00 8.890E-09 1.440E-08 SKIN(FGR) 2.980E-14 1.825E-11 2.920E-10 6.430E-16-1.000E+00 0.000E+00 0.000E+00 I-132 GONADS 1.090E-13 2.523E-11 2.771E-11 2.320E-15-1.000E+00 9.950E-12 2.330E-11 BREAST 1.240E-13 2.414E-11 2.652E-11 2.220E-15-1.000E+00 1.410E-11 2.520E-11 LUNGS 1.090E-13 2.305E-11 2.532E-11 2.120E-15-1.000E+00 2.710E-10 2.640E-11 RED MARR 1.070E-13 2.360E-11 2.592E-11 2.170E-15-1.000E+00 1.400E-11 2.460E-11 BONE SUR 1.730E-13 3.327E-11 3.655E-11 3.060E-15-1.000E+00 1.240E-11 2.190E-11 THYROID 1.120E-13 2.381E-11 2.616E-11 2.190E-15-1.000E+00 1.740E-09 3.870E-09 REMAINDER 1.050E-13 2.283E-11 2.509E-11 2.100E-15-1.000E+00 3.780E-11 1.650E-10 EFFECTIVE 1.120E-13 2.403E-11 2.640E-11 2.210E-15-1.000E+00 1.030E-10 1.820E-10 SKIN(FGR) 1.580E-13 8.199E-11 9.007E-11 7.540E-15-1.000E+00 0.000E+00 0.000E+00 I-133 GONADS 2.870E-14 1.585E-11 6.748E-11 6.270E-16-1.000E+00 1.950E-11 3.630E-11 BREAST 3.280E-14 1.519E-11 6.468E-11 6.010E-16-1.000E+00 2.940E-11 4.680E-11 LUNGS 2.860E-14 1.446E-11 6.156E-11 5.720E-16-1.000E+00 8.200E-10 4.530E-11 RED MARR 2.770E-14 1.466E-11 6.242E-11 5.800E-16-1.000E+00 2.720E-11 4.300E-11 BONE SUR 4.870E-14 2.161E-11 9.202E-11 8.550E-16-1.000E+00 2.520E-11 4.070E-11 THYROID 2.930E-14 1.502E-11 6.393E-11 5.940E-16-1.000E+00 4.860E-08 9.100E-08 REMAINDER 2.730E-14 1.418E-11 6.038E-11 5.610E-16-1.000E+00 5.000E-11 1.550E-10 EFFECTIVE 2.940E-14 1.509E-11 6.425E-11 5.970E-16-1.000E+00 1.580E-09 2.800E-09 SKIN(FGR) 5.830E-14 1.150E-10 4.897E-10 4.550E-15-1.000E+00 0.000E+00 0.000E+00 I-134 GONADS 1.270E-13 1.200E-11 1.202E-11 2.640E-15-1.000E+00 4.250E-12 1.100E-11 BREAST 1.440E-13 1.145E-11 1.147E-11 2.520E-15-1.000E+00 6.170E-12 1.170E-11 LUNGS 1.270E-13 1.100E-11 1.102E-11 2.420E-15-1.000E+00 1.430E-10 1.260E-11 RED MARR 1.250E-13 1.127E-11 1.129E-11 2.480E-15-1.000E+00 6.080E-12 1.090E-11 BONE SUR 1.960E-13 1.568E-11 1.571E-11 3.450E-15-1.000E+00 5.310E-12 9.320E-12 THYROID 1.300E-13 1.127E-11 1.129E-11 2.480E-15-1.000E+00 2.880E-10 6.210E-10 REMAINDER 1.220E-13 1.091E-11 1.093E-11 2.400E-15-1.000E+00 2.270E-11 1.340E-10 EFFECTIVE 1.300E-13 1.150E-11 1.152E-11 2.530E-15-1.000E+00 3.550E-11 6.660E-11 SKIN(FGR) 1.870E-13 4.477E-11 4.485E-11 9.850E-15-1.000E+00 0.000E+00 0.000E+00 I-135 GONADS 7.770E-14 3.113E-11 5.489E-11 1.599E-15-1.000E+00 1.700E-11 3.610E-11 BREAST 8.790E-14 2.971E-11 5.240E-11 1.526E-15-1.000E+00 2.340E-11 3.850E-11 LUNGS 7.840E-14 2.886E-11 5.089E-11 1.482E-15-1.000E+00 4.410E-10 3.750E-11 RED MARR 7.760E-14 2.965E-11 5.228E-11 1.523E-15-1.000E+00 2.240E-11 3.650E-11 BONE SUR 1.130E-13 3.983E-11 7.024E-11 2.046E-15-1.000E+00 2.010E-11 3.360E-11 THYROID 8.010E-14 2.852E-11 5.030E-11 1.465E-15-1.000E+00 8.460E-09 1.790E-08 REMAINDER 7.570E-14 2.883E-11 5.084E-11 1.481E-15-1.000E+00 4.700E-11 1.540E-10 EFFECTIVE 7.980E-14 2.989E-11 5.271E-11 1.535E-15-1.000E+00 3.320E-10 6.080E-10 SKIN(FGR) 1.110E-13 9.826E-11 1.733E-10 5.047E-15-1.000E+00 0.000E+00 0.000E+00 Xe-133 GONADS 1.610E-15 1.465E-12 2.052E-11 5.200E-17-1.000E+00 0.000E+00 0.000E+00 BREAST 1.960E-15 1.505E-12 2.107E-11 5.340E-17-1.000E+00 0.000E+00 0.000E+00 LUNGS 1.320E-15 1.045E-12 1.464E-11 3.710E-17-1.000E+00 0.000E+00 0.000E+00 RED MARR 1.070E-15 8.791E-13 1.231E-11 3.120E-17-1.000E+00 0.000E+00 0.000E+00 BONE SUR 5.130E-15 4.254E-12 5.958E-11 1.510E-16-1.000E+00 0.000E+00 0.000E+00 THYROID 1.510E-15 1.181E-12 1.653E-11 4.190E-17-1.000E+00 0.000E+00 0.000E+00 REMAINDER 1.240E-15 1.042E-12 1.460E-11 3.700E-17-1.000E+00 0.000E+00 0.000E+00 EFFECTIVE 1.560E-15 1.299E-12 1.819E-11 4.610E-17-1.000E+00 0.000E+00 0.000E+00 SKIN(FGR) 4.970E-15 1.953E-12 2.734E-11 6.930E-17-1.000E+00 0.000E+00 0.000E+00 Xe-135 GONADS 1.170E-14 5.455E-12 1.194E-11 2.530E-16-1.000E+00 0.000E+00 0.000E+00 BREAST 1.330E-14 5.325E-12 1.166E-11 2.470E-16-1.000E+00 0.000E+00 0.000E+00 LUNGS 1.130E-14 4.959E-12 1.086E-11 2.300E-16-1.000E+00 0.000E+00 0.000E+00 RED MARR 1.070E-14 4.959E-12 1.086E-11 2.300E-16-1.000E+00 0.000E+00 0.000E+00 BONE SUR 2.570E-14 9.120E-12 1.997E-11 4.230E-16-1.000E+00 0.000E+00 0.000E+00 THYROID 1.180E-14 5.023E-12 1.100E-11 2.330E-16-1.000E+00 0.000E+00 0.000E+00

Numerical Applications Inc. Attachment 3 Page 58 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 REMAINDER 1.080E-14 4.829E-12 1.058E-11 2.240E-16-1.000E+00 0.000E+00 0.000E+00 EFFECTIVE 1.190E-14 5.217E-12 1.142E-11 2.420E-16-1.000E+00 0.000E+00 0.000E+00 SKIN(FGR) 3.120E-14 4.506E-11 9.867E-11 2.090E-15-1.000E+00 0.000E+00 0.000E+00 Cs-134 GONADS 7.400E-14 4.607E-11 9.646E-10 1.600E-15-1.000E+00 1.300E-08 2.060E-08 BREAST 8.430E-14 4.406E-11 9.224E-10 1.530E-15-1.000E+00 1.080E-08 1.720E-08 LUNGS 7.370E-14 4.204E-11 8.802E-10 1.460E-15-1.000E+00 1.180E-08 1.760E-08 RED MARR 7.190E-14 4.262E-11 8.922E-10 1.480E-15-1.000E+00 1.180E-08 1.870E-08 BONE SUR 1.200E-13 6.105E-11 1.278E-09 2.120E-15-1.000E+00 1.100E-08 1.740E-08 THYROID 7.570E-14 4.377E-11 9.163E-10 1.520E-15-1.000E+00 1.110E-08 1.760E-08 REMAINDER 7.060E-14 4.147E-11 8.681E-10 1.440E-15-1.000E+00 1.390E-08 2.210E-08 EFFECTIVE 7.570E-14 4.377E-11 9.163E-10 1.520E-15-1.000E+00 1.250E-08 1.980E-08 SKIN(FGR) 9.450E-14 6.249E-11 1.308E-09 2.170E-15-1.000E+00 0.000E+00 0.000E+00 Cs-136 GONADS 1.040E-13 6.223E-11 1.102E-09 2.180E-15-1.000E+00 1.880E-09 3.040E-09 BREAST 1.180E-13 5.966E-11 1.056E-09 2.090E-15-1.000E+00 1.670E-09 2.650E-09 LUNGS 1.040E-13 5.710E-11 1.011E-09 2.000E-15-1.000E+00 2.320E-09 2.620E-09 RED MARR 1.010E-13 5.824E-11 1.031E-09 2.040E-15-1.000E+00 1.860E-09 2.950E-09 BONE SUR 1.660E-13 8.422E-11 1.491E-09 2.950E-15-1.000E+00 1.700E-09 2.710E-09 THYROID 1.070E-13 5.852E-11 1.036E-09 2.050E-15-1.000E+00 1.730E-09 2.740E-09 REMAINDER 9.950E-14 5.652E-11 1.001E-09 1.980E-15-1.000E+00 2.190E-09 3.520E-09 EFFECTIVE 1.060E-13 5.966E-11 1.056E-09 2.090E-15-1.000E+00 1.980E-09 3.040E-09 SKIN(FGR) 1.250E-13 7.251E-11 1.284E-09 2.540E-15-1.000E+00 0.000E+00 0.000E+00 Cs-137 GONADS 7.960E-18 1.669E-11 3.530E-10 5.840E-16-1.000E+00 8.760E-09 1.390E-08 BREAST 9.670E-18 1.596E-11 3.376E-10 5.585E-16-1.000E+00 7.840E-09 1.240E-08 LUNGS 6.680E-18 1.517E-11 3.209E-10 5.309E-16-1.000E+00 8.820E-09 1.270E-08 RED MARR 5.700E-18 1.542E-11 3.260E-10 5.394E-16-1.000E+00 8.300E-09 1.320E-08 BONE SUR 2.290E-17 2.238E-11 4.734E-10 7.832E-16-1.000E+00 7.940E-09 1.260E-08 THYROID 7.550E-18 1.588E-11 3.358E-10 5.556E-16-1.000E+00 7.930E-09 1.260E-08 REMAINDER 6.340E-18 1.490E-11 3.152E-10 5.215E-16-1.000E+00 9.120E-09 1.450E-08 EFFECTIVE 7.740E-18 1.585E-11 3.353E-10 5.546E-16-1.000E+00 8.630E-09 1.350E-08 SKIN(FGR) 8.630E-15 5.253E-11 1.110E-09 1.836E-15-1.000E+00 0.000E+00 0.000E+00 Ba-139 GONADS 2.130E-15 3.368E-13 3.429E-13 4.790E-17-1.000E+00 2.560E-12 1.560E-12 BREAST 2.450E-15 3.297E-13 3.357E-13 4.690E-17-1.000E+00 2.460E-12 5.170E-13 LUNGS 2.030E-15 3.002E-13 3.057E-13 4.270E-17-1.000E+00 2.530E-10 3.890E-13 RED MARR 1.870E-15 2.932E-13 2.985E-13 4.170E-17-1.000E+00 3.410E-12 8.590E-13 BONE SUR 5.290E-15 6.841E-13 6.965E-13 9.730E-17-1.000E+00 2.490E-12 4.380E-13 THYROID 2.130E-15 3.044E-13 3.100E-13 4.330E-17-1.000E+00 2.400E-12 2.660E-13 REMAINDER 1.920E-15 2.932E-13 2.985E-13 4.170E-17-1.000E+00 4.820E-11 3.570E-10 EFFECTIVE 2.170E-15 3.227E-13 3.286E-13 4.590E-17-1.000E+00 4.640E-11 1.080E-10 SKIN(FGR) 6.160E-14 7.241E-11 7.373E-11 1.030E-14-1.000E+00 0.000E+00 0.000E+00 Ba-140 GONADS 8.410E-15 5.451E-12 9.607E-11 1.910E-16-1.000E+00 4.300E-10 9.960E-10 BREAST 9.640E-15 5.280E-12 9.305E-11 1.850E-16-1.000E+00 2.870E-10 1.590E-10 LUNGS 8.270E-15 4.852E-12 8.550E-11 1.700E-16-1.000E+00 1.660E-09 6.630E-11 RED MARR 7.930E-15 4.880E-12 8.601E-11 1.710E-16-1.000E+00 1.290E-09 4.390E-10 BONE SUR 1.550E-14 8.020E-12 1.413E-10 2.810E-16-1.000E+00 2.410E-09 5.530E-10 THYROID 8.530E-15 5.109E-12 9.003E-11 1.790E-16-1.000E+00 2.560E-10 5.250E-11 REMAINDER 7.890E-15 4.766E-12 8.399E-11 1.670E-16-1.000E+00 1.410E-09 7.370E-09 EFFECTIVE 8.580E-15 5.137E-12 9.053E-11 1.800E-16-1.000E+00 1.010E-09 2.560E-09 SKIN(FGR) 2.520E-14 5.565E-11 9.808E-10 1.950E-15-1.000E+00 0.000E+00 0.000E+00 La-140 GONADS 1.140E-13 6.027E-11 4.425E-10 2.240E-15-1.000E+00 4.540E-10 1.340E-09 BREAST 1.290E-13 5.758E-11 4.228E-10 2.140E-15-1.000E+00 1.450E-10 1.800E-10 LUNGS 1.150E-13 5.596E-11 4.109E-10 2.080E-15-1.000E+00 4.210E-09 4.010E-11 RED MARR 1.140E-13 5.731E-11 4.208E-10 2.130E-15-1.000E+00 2.140E-10 2.810E-10 BONE SUR 1.690E-13 7.776E-11 5.709E-10 2.890E-15-1.000E+00 1.410E-10 9.770E-11 THYROID 1.180E-13 5.462E-11 4.010E-10 2.030E-15-1.000E+00 6.870E-11 6.400E-12 REMAINDER 1.110E-13 5.569E-11 4.089E-10 2.070E-15-1.000E+00 2.120E-09 6.260E-09 EFFECTIVE 1.170E-13 5.812E-11 4.267E-10 2.160E-15-1.000E+00 1.310E-09 2.280E-09 SKIN(FGR) 1.660E-13 2.217E-10 1.628E-09 8.240E-15-1.000E+00 0.000E+00 0.000E+00 La-141 GONADS 2.330E-15 7.315E-13 9.675E-13 4.740E-17-1.000E+00 1.010E-11 3.770E-12 BREAST 2.640E-15 7.007E-13 9.267E-13 4.540E-17-1.000E+00 9.840E-12 7.070E-13 LUNGS 2.340E-15 6.713E-13 8.879E-13 4.350E-17-1.000E+00 6.460E-10 2.720E-13 RED MARR 2.310E-15 6.852E-13 9.063E-13 4.440E-17-1.000E+00 2.930E-11 1.070E-12 BONE SUR 3.490E-15 9.923E-13 1.312E-12 6.430E-17-1.000E+00 1.200E-10 6.060E-13 THYROID 2.390E-15 6.590E-13 8.716E-13 4.270E-17-1.000E+00 9.400E-12 5.290E-14 REMAINDER 2.260E-15 6.682E-13 8.838E-13 4.330E-17-1.000E+00 2.280E-10 1.240E-09 EFFECTIVE 2.390E-15 7.007E-13 9.267E-13 4.540E-17-1.000E+00 1.570E-10 3.740E-10 SKIN(FGR) 6.580E-14 1.667E-10 2.204E-10 1.080E-14-1.000E+00 0.000E+00 0.000E+00

Numerical Applications Inc. Attachment 3 Page 59 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 La-142 GONADS 1.400E-13 1.978E-11 2.034E-11 2.540E-15-1.000E+00 1.660E-11 6.990E-11 BREAST 1.570E-13 1.885E-11 1.938E-11 2.420E-15-1.000E+00 1.130E-11 1.540E-11 LUNGS 1.420E-13 1.846E-11 1.898E-11 2.370E-15-1.000E+00 3.010E-10 8.400E-12 RED MARR 1.420E-13 1.900E-11 1.954E-11 2.440E-15-1.000E+00 1.360E-11 1.930E-11 BONE SUR 1.950E-13 2.484E-11 2.554E-11 3.190E-15-1.000E+00 1.110E-11 7.400E-12 THYROID 1.450E-13 1.768E-11 1.818E-11 2.270E-15-1.000E+00 8.740E-12 1.160E-12 REMAINDER 1.380E-13 1.853E-11 1.906E-11 2.380E-15-1.000E+00 8.070E-11 5.200E-10 EFFECTIVE 1.440E-13 1.916E-11 1.970E-11 2.460E-15-1.000E+00 6.840E-11 1.790E-10 SKIN(FGR) 2.160E-13 9.111E-11 9.368E-11 1.170E-14-1.000E+00 0.000E+00 0.000E+00 Ce-141 GONADS 3.380E-15 2.213E-12 4.332E-11 7.710E-17-1.000E+00 5.540E-11 1.080E-10 BREAST 3.930E-15 2.170E-12 4.247E-11 7.560E-17-1.000E+00 4.460E-11 1.110E-11 LUNGS 3.170E-15 1.951E-12 3.820E-11 6.800E-17-1.000E+00 1.670E-08 1.430E-12 RED MARR 2.830E-15 1.860E-12 3.641E-11 6.480E-17-1.000E+00 8.960E-11 3.390E-11 BONE SUR 9.410E-15 5.166E-12 1.011E-10 1.800E-16-1.000E+00 2.540E-10 2.300E-11 THYROID 3.350E-15 2.003E-12 3.922E-11 6.980E-17-1.000E+00 2.550E-11 1.800E-13 REMAINDER 2.980E-15 1.894E-12 3.708E-11 6.600E-17-1.000E+00 1.260E-09 2.500E-09 EFFECTIVE 3.430E-15 2.118E-12 4.146E-11 7.380E-17-1.000E+00 2.420E-09 7.830E-10 SKIN(FGR) 1.020E-14 3.788E-12 7.416E-11 1.320E-16-1.000E+00 0.000E+00 0.000E+00 Ce-143 GONADS 1.280E-14 7.900E-12 4.958E-11 2.980E-16-1.000E+00 7.530E-11 2.120E-10 BREAST 1.470E-14 7.688E-12 4.825E-11 2.900E-16-1.000E+00 1.660E-11 2.320E-11 LUNGS 1.230E-14 6.893E-12 4.325E-11 2.600E-16-1.000E+00 3.880E-09 3.820E-12 RED MARR 1.170E-14 6.787E-12 4.259E-11 2.560E-16-1.000E+00 2.960E-11 5.070E-11 BONE SUR 2.520E-14 1.323E-11 8.302E-11 4.990E-16-1.000E+00 1.640E-11 1.610E-11 THYROID 1.280E-14 7.211E-12 4.525E-11 2.720E-16-1.000E+00 6.230E-12 4.350E-13 REMAINDER 1.170E-14 6.734E-12 4.226E-11 2.540E-16-1.000E+00 1.420E-09 3.890E-09 EFFECTIVE 1.290E-14 7.396E-12 4.642E-11 2.790E-16-1.000E+00 9.160E-10 1.230E-09 SKIN(FGR) 3.960E-14 1.058E-10 6.638E-10 3.990E-15-1.000E+00 0.000E+00 0.000E+00 Ce-144 GONADS 8.530E-16 6.328E-13 1.319E-11 6.088E-17-1.000E+00 2.390E-10 6.987E-11 BREAST 1.010E-15 6.274E-13 1.307E-11 5.922E-17-1.000E+00 3.480E-10 1.223E-11 LUNGS 7.690E-16 5.228E-13 1.089E-11 5.362E-17-1.000E+00 7.910E-07 6.551E-12 RED MARR 6.680E-16 4.755E-13 9.907E-12 5.247E-17-1.000E+00 2.880E-09 8.923E-11 BONE SUR 2.490E-15 1.646E-12 3.429E-11 1.127E-16-1.000E+00 4.720E-09 1.280E-10 THYROID 8.330E-16 5.529E-13 1.152E-11 5.418E-17-1.000E+00 2.920E-10 5.154E-12 REMAINDER 7.230E-16 5.086E-13 1.060E-11 5.283E-17-1.000E+00 1.910E-08 1.890E-08 EFFECTIVE 8.530E-16 5.909E-13 1.231E-11 5.766E-17-1.000E+00 1.010E-07 5.711E-09 SKIN(FGR) 2.930E-15 7.648E-13 1.594E-11 1.250E-14-1.000E+00 0.000E+00 0.000E+00 Pr-143 GONADS 2.130E-17 2.264E-14 4.032E-13 7.930E-19-1.000E+00 4.370E-18 8.990E-18 BREAST 2.550E-17 2.330E-14 4.149E-13 8.160E-19-1.000E+00 2.220E-18 1.090E-18 LUNGS 1.860E-17 1.642E-14 2.923E-13 5.750E-19-1.000E+00 1.330E-08 1.910E-19 RED MARR 1.620E-17 1.493E-14 2.659E-13 5.230E-19-1.000E+00 1.480E-11 1.030E-12 BONE SUR 5.930E-17 5.454E-14 9.711E-13 1.910E-18-1.000E+00 1.490E-11 1.030E-12 THYROID 2.050E-17 1.802E-14 3.208E-13 6.310E-19-1.000E+00 1.680E-18 2.660E-20 REMAINDER 1.760E-17 1.642E-14 2.923E-13 5.750E-19-1.000E+00 1.970E-09 4.220E-09 EFFECTIVE 2.100E-17 2.002E-14 3.564E-13 7.010E-19-1.000E+00 2.190E-09 1.270E-09 SKIN(FGR) 1.760E-14 5.711E-11 1.017E-09 2.000E-15-1.000E+00 0.000E+00 0.000E+00 Nd-147 GONADS 6.130E-15 4.218E-12 7.235E-11 1.480E-16-1.000E+00 8.410E-11 1.790E-10 BREAST 7.120E-15 4.132E-12 7.088E-11 1.450E-16-1.000E+00 3.450E-11 1.870E-11 LUNGS 5.820E-15 3.648E-12 6.257E-11 1.280E-16-1.000E+00 1.060E-08 2.440E-12 RED MARR 5.400E-15 3.505E-12 6.013E-11 1.230E-16-1.000E+00 9.190E-11 5.050E-11 BONE SUR 1.320E-14 8.265E-12 1.418E-10 2.900E-16-1.000E+00 3.260E-10 2.220E-11 THYROID 6.120E-15 3.876E-12 6.648E-11 1.360E-16-1.000E+00 1.820E-11 2.640E-13 REMAINDER 5.530E-15 3.562E-12 6.111E-11 1.250E-16-1.000E+00 1.760E-09 3.760E-09 EFFECTIVE 6.190E-15 3.961E-12 6.795E-11 1.390E-16-1.000E+00 1.850E-09 1.180E-09 SKIN(FGR) 1.950E-14 3.135E-11 5.377E-10 1.100E-15-1.000E+00 0.000E+00 0.000E+00 Np-239 GONADS 7.530E-15 4.691E-12 4.380E-11 1.710E-16-1.000E+00 7.450E-11 1.620E-10 BREAST 8.730E-15 4.636E-12 4.329E-11 1.690E-16-1.000E+00 1.630E-11 1.720E-11 LUNGS 7.180E-15 4.115E-12 3.842E-11 1.500E-16-1.000E+00 2.360E-09 2.400E-12 RED MARR 6.500E-15 4.005E-12 3.740E-11 1.460E-16-1.000E+00 2.080E-10 4.660E-11 BONE SUR 2.000E-14 1.001E-11 9.349E-11 3.650E-16-1.000E+00 2.030E-09 3.590E-11 THYROID 7.520E-15 4.197E-12 3.919E-11 1.530E-16-1.000E+00 7.620E-12 2.070E-13 REMAINDER 6.760E-15 4.005E-12 3.740E-11 1.460E-16-1.000E+00 9.590E-10 2.770E-09 EFFECTIVE 7.690E-15 4.471E-12 4.175E-11 1.630E-16-1.000E+00 6.780E-10 8.820E-10 SKIN(FGR) 1.600E-14 7.215E-12 6.737E-11 2.630E-16-1.000E+00 0.000E+00 0.000E+00 Pu-238 GONADS 6.560E-18 4.291E-14 9.011E-13 1.490E-18-1.000E+00 2.800E-05 2.330E-09 BREAST 1.270E-17 5.558E-14 1.167E-12 1.930E-18-1.000E+00 1.000E-09 1.800E-13

Numerical Applications Inc. Attachment 3 Page 60 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 LUNGS 1.060E-18 2.267E-15 4.759E-14 7.870E-20-1.000E+00 1.840E-05 8.640E-14 RED MARR 1.680E-18 5.587E-15 1.173E-13 1.940E-19-1.000E+00 1.520E-04 1.270E-08 BONE SUR 9.300E-18 3.514E-14 7.378E-13 1.220E-18-1.000E+00 1.900E-03 1.580E-07 THYROID 4.010E-18 9.792E-15 2.056E-13 3.400E-19-1.000E+00 9.620E-10 7.990E-14 REMAINDER 1.990E-18 9.216E-15 1.935E-13 3.200E-19-1.000E+00 7.020E-05 2.180E-08 EFFECTIVE 4.880E-18 2.413E-14 5.068E-13 8.380E-19-1.000E+00 1.060E-04 1.340E-08 SKIN(FGR) 4.090E-17 2.776E-13 5.830E-12 9.640E-18-1.000E+00 0.000E+00 0.000E+00 Pu-239 GONADS 4.840E-18 1.768E-14 3.713E-13 6.140E-19-1.000E+00 3.180E-05 2.640E-09 BREAST 7.550E-18 2.238E-14 4.699E-13 7.770E-19-1.000E+00 9.220E-10 1.210E-13 LUNGS 2.650E-18 2.267E-15 4.760E-14 7.870E-20-1.000E+00 1.730E-05 7.890E-14 RED MARR 2.670E-18 3.456E-15 7.258E-14 1.200E-19-1.000E+00 1.690E-04 1.410E-08 BONE SUR 9.470E-18 1.673E-14 3.514E-13 5.810E-19-1.000E+00 2.110E-03 1.760E-07 THYROID 3.880E-18 5.126E-15 1.077E-13 1.780E-19-1.000E+00 9.030E-10 7.500E-14 REMAINDER 2.860E-18 4.838E-15 1.016E-13 1.680E-19-1.000E+00 7.560E-05 2.120E-08 EFFECTIVE 4.240E-18 1.057E-14 2.220E-13 3.670E-19-1.000E+00 1.160E-05 1.400E-08 SKIN(FGR) 1.860E-17 1.057E-13 2.220E-12 3.670E-18-1.000E+00 0.000E+00 0.000E+00 Pu-240 GONADS 6.360E-18 4.118E-14 8.649E-13 1.430E-18-1.000E+00 3.180E-05 2.640E-09 BREAST 1.230E-17 5.328E-14 1.119E-12 1.850E-18-1.000E+00 9.510E-10 1.730E-13 LUNGS 1.090E-18 2.249E-15 4.723E-14 7.810E-20-1.000E+00 1.730E-05 8.220E-14 RED MARR 1.650E-18 5.386E-15 1.131E-13 1.870E-19-1.000E+00 1.690E-04 1.410E-08 BONE SUR 9.260E-18 3.398E-14 7.137E-13 1.180E-18-1.000E+00 2.110E-03 1.760E-07 THYROID 3.920E-18 9.446E-15 1.984E-13 3.280E-19-1.000E+00 9.050E-10 7.510E-14 REMAINDER 1.960E-18 8.870E-15 1.863E-13 3.080E-19-1.000E+00 7.560E-05 2.130E-08 EFFECTIVE 4.750E-18 2.313E-14 4.857E-13 8.030E-19-1.000E+00 1.160E-04 1.400E-08 SKIN(FGR) 3.920E-17 2.644E-13 5.552E-12 9.180E-18-1.000E+00 0.000E+00 0.000E+00 Pu-241 GONADS 7.190E-20 6.653E-17 1.396E-15 2.310E-21-1.000E+00 6.820E-07 5.660E-11 BREAST 8.670E-20 7.229E-17 1.517E-15 2.510E-21-1.000E+00 3.060E-11 2.790E-15 LUNGS 6.480E-20 4.090E-17 8.584E-16 1.420E-21-1.000E+00 7.420E-09 4.480E-15 RED MARR 5.630E-20 4.003E-17 8.403E-16 1.390E-21-1.000E+00 3.360E-06 2.780E-10 BONE SUR 2.190E-19 1.385E-16 2.908E-15 4.810E-21-1.000E+00 4.200E-05 3.480E-09 THYROID 6.980E-20 4.522E-17 9.491E-16 1.570E-21-1.000E+00 1.240E-11 1.010E-15 REMAINDER 6.090E-20 4.291E-17 9.007E-16 1.490E-21-1.000E+00 1.310E-06 1.850E-10 EFFECTIVE 7.250E-20 5.558E-17 1.167E-15 1.930E-21-1.000E+00 2.230E-06 2.070E-10 SKIN(FGR) 1.170E-19 2.033E-16 4.268E-15 7.060E-21-1.000E+00 0.000E+00 0.000E+00 Am-241 GONADS 8.580E-16 9.360E-13 1.966E-11 3.250E-17-1.000E+00 3.250E-05 2.700E-07 BREAST 1.070E-15 1.014E-12 2.129E-11 3.520E-17-1.000E+00 2.670E-09 2.620E-11 LUNGS 6.740E-16 5.789E-13 1.216E-11 2.010E-17-1.000E+00 1.840E-05 3.360E-11 RED MARR 5.210E-16 4.838E-13 1.016E-11 1.680E-17-1.000E+00 1.740E-04 1.450E-06 BONE SUR 2.870E-15 2.678E-12 5.625E-11 9.300E-17-1.000E+00 2.170E-03 1.810E-05 THYROID 7.830E-16 6.365E-13 1.337E-11 2.210E-17-1.000E+00 1.600E-09 1.320E-11 REMAINDER 6.340E-16 5.933E-13 1.246E-11 2.060E-17-1.000E+00 7.820E-05 6.660E-07 EFFECTIVE 8.180E-16 7.920E-13 1.663E-11 2.750E-17-1.000E+00 1.200E-04 9.840E-07 SKIN(FGR) 1.280E-15 2.396E-12 5.032E-11 8.320E-17-1.000E+00 0.000E+00 0.000E+00 Cm-242 GONADS 7.830E-18 4.893E-14 1.013E-12 1.700E-18-1.000E+00 5.700E-07 5.200E-09 BREAST 1.480E-17 6.159E-14 1.275E-12 2.140E-18-1.000E+00 9.440E-10 8.950E-12 LUNGS 1.130E-18 3.022E-15 6.257E-14 1.050E-19-1.000E+00 1.550E-05 8.840E-12 RED MARR 1.890E-18 6.562E-15 1.359E-13 2.280E-19-1.000E+00 3.900E-06 3.570E-08 BONE SUR 1.060E-17 4.231E-14 8.759E-13 1.470E-18-1.000E+00 4.870E-05 4.460E-07 THYROID 4.910E-18 1.261E-14 2.610E-13 4.380E-19-1.000E+00 9.410E-10 8.820E-12 REMAINDER 2.270E-18 1.079E-14 2.235E-13 3.750E-19-1.000E+00 2.450E-06 4.020E-08 EFFECTIVE 5.690E-18 2.751E-14 5.697E-13 9.560E-19-1.000E+00 4.670E-06 3.100E-08 SKIN(FGR) 4.290E-17 2.700E-13 5.589E-12 9.380E-18-1.000E+00 0.000E+00 0.000E+00 Cm-244 GONADS 6.900E-18 4.522E-14 9.492E-13 1.570E-18-1.000E+00 1.590E-05 1.330E-07 BREAST 1.330E-17 5.702E-14 1.197E-12 1.980E-18-1.000E+00 1.040E-09 8.820E-12 LUNGS 7.080E-19 2.592E-15 5.441E-14 9.000E-20-1.000E+00 1.930E-05 8.810E-12 RED MARR 1.460E-18 5.875E-15 1.233E-13 2.040E-19-1.000E+00 9.380E-05 7.820E-07 BONE SUR 8.820E-18 3.859E-14 8.101E-13 1.340E-18-1.000E+00 1.170E-03 9.770E-06 THYROID 4.190E-18 1.146E-14 2.406E-13 3.980E-19-1.000E+00 1.010E-09 8.440E-12 REMAINDER 1.810E-18 9.821E-15 2.062E-13 3.410E-19-1.000E+00 4.780E-05 4.150E-07 EFFECTIVE 4.910E-18 2.529E-14 5.308E-13 8.780E-19-1.000E+00 6.700E-05 5.450E-07 SKIN(FGR) 3.910E-17 2.506E-13 5.260E-12 8.700E-18-1.000E+00 0.000E+00 0.000E+00 I-130 GONADS 1.010E-13 2.867E-11 5.828E-10 9.970E-16-1.000E+00 2.810E-11 1.040E-09 BREAST 1.160E-13 2.737E-11 5.565E-10 9.520E-16-1.000E+00 4.870E-11 1.790E-10 LUNGS 1.010E-13 2.617E-11 5.319E-10 9.100E-16-1.000E+00 6.030E-10 8.530E-11 RED MARR 9.820E-14 2.671E-11 5.430E-10 9.290E-16-1.000E+00 4.550E-11 2.600E-10 BONE SUR 1.680E-13 3.795E-11 7.716E-10 1.320E-15-1.000E+00 4.030E-11 1.250E-10

Numerical Applications Inc. Attachment 3 Page 61 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 THYROID 1.040E-13 2.720E-11 5.530E-10 9.460E-16-1.000E+00 1.990E-08 6.310E-11 REMAINDER 9.660E-14 2.585E-11 5.255E-10 8.990E-16-1.000E+00 8.020E-11 1.580E-09 EFFECTIVE 1.040E-13 2.732E-11 5.553E-10 9.500E-16-1.000E+00 7.140E-10 8.090E-10 SKIN(FGR) 1.360E-13 3.278E-11 6.664E-10 1.140E-15-1.000E+00 0.000E+00 0.000E+00 Kr-83m GONADS 1.710E-18 7.056E-11 1.480E-09 2.450E-15-1.000E+00 0.000E+00 3.190E-09 BREAST 5.050E-18 6.739E-11 1.413E-09 2.340E-15-1.000E+00 0.000E+00 1.100E-09 LUNGS 1.640E-19 6.537E-11 1.371E-09 2.270E-15-1.000E+00 0.000E+00 8.770E-10 RED MARR 3.830E-19 6.710E-11 1.407E-09 2.330E-15-1.000E+00 0.000E+00 1.320E-09 BONE SUR 2.250E-18 8.956E-11 1.879E-09 3.110E-15-1.000E+00 0.000E+00 9.390E-10 THYROID 6.430E-19 6.480E-11 1.359E-09 2.250E-15-1.000E+00 0.000E+00 7.880E-10 REMAINDER 5.300E-19 6.508E-11 1.365E-09 2.260E-15-1.000E+00 0.000E+00 4.970E-09 EFFECTIVE 1.500E-18 6.768E-11 1.419E-09 2.350E-15-1.000E+00 0.000E+00 2.770E-09 SKIN(FGR) 3.560E-17 7.948E-11 1.667E-09 2.760E-15-1.000E+00 0.000E+00 0.000E+00 Xe-138 GONADS 5.590E-14 8.121E-14 1.704E-12 2.820E-18-1.000E+00 0.000E+00 0.000E+00 BREAST 6.320E-14 7.891E-14 1.656E-12 2.740E-18-1.000E+00 0.000E+00 0.000E+00 LUNGS 5.660E-14 7.056E-14 1.481E-12 2.450E-18-1.000E+00 0.000E+00 0.000E+00 RED MARR 5.600E-14 6.998E-14 1.469E-12 2.430E-18-1.000E+00 0.000E+00 0.000E+00 BONE SUR 8.460E-14 1.287E-13 2.702E-12 4.470E-18-1.000E+00 0.000E+00 0.000E+00 THYROID 5.770E-14 7.459E-14 1.565E-12 2.590E-18-1.000E+00 0.000E+00 0.000E+00 REMAINDER 5.490E-14 6.941E-14 1.457E-12 2.410E-18-1.000E+00 0.000E+00 0.000E+00 EFFECTIVE 5.770E-14 7.603E-14 1.596E-12 2.640E-18-1.000E+00 0.000E+00 0.000E+00 SKIN(FGR) 1.070E-13 2.304E-11 4.835E-10 8.000E-16-1.000E+00 0.000E+00 0.000E+00 Xe-131m GONADS 4.570E-16 2.594E-12 3.653E-12 1.570E-16-1.000E+00 0.000E+00 0.000E+00 BREAST 6.020E-16 2.527E-12 3.560E-12 1.530E-16-1.000E+00 0.000E+00 0.000E+00 LUNGS 2.670E-16 2.379E-12 3.351E-12 1.440E-16-1.000E+00 0.000E+00 0.000E+00 RED MARR 2.270E-16 2.346E-12 3.304E-12 1.420E-16-1.000E+00 0.000E+00 0.000E+00 BONE SUR 1.060E-15 5.286E-12 7.446E-12 3.200E-16-1.000E+00 0.000E+00 0.000E+00 THYROID 3.910E-16 2.395E-12 3.374E-12 1.450E-16-1.000E+00 0.000E+00 0.000E+00 REMAINDER 2.710E-16 2.313E-12 3.257E-12 1.400E-16-1.000E+00 0.000E+00 0.000E+00 EFFECTIVE 3.890E-16 2.511E-12 3.537E-12 1.520E-16-1.000E+00 0.000E+00 0.000E+00 SKIN(FGR) 4.820E-15 2.247E-11 3.164E-11 1.360E-15-1.000E+00 0.000E+00 0.000E+00 Xe-133m GONADS 1.420E-15 4.962E-12 5.026E-12 7.610E-16-1.000E+00 0.000E+00 0.000E+00 BREAST 1.700E-15 4.740E-12 4.802E-12 7.270E-16-1.000E+00 0.000E+00 0.000E+00 LUNGS 1.190E-15 4.603E-12 4.663E-12 7.060E-16-1.000E+00 0.000E+00 0.000E+00 RED MARR 1.100E-15 4.708E-12 4.769E-12 7.220E-16-1.000E+00 0.000E+00 0.000E+00 BONE SUR 3.230E-15 6.514E-12 6.598E-12 9.990E-16-1.000E+00 0.000E+00 0.000E+00 THYROID 1.360E-15 4.473E-12 4.531E-12 6.860E-16-1.000E+00 0.000E+00 0.000E+00 REMAINDER 1.150E-15 4.590E-12 4.650E-12 7.040E-16-1.000E+00 0.000E+00 0.000E+00 EFFECTIVE 1.370E-15 4.773E-12 4.835E-12 7.320E-16-1.000E+00 0.000E+00 0.000E+00 SKIN(FGR) 1.040E-14 8.802E-11 8.916E-11 1.350E-14-1.000E+00 0.000E+00 0.000E+00 Xe-135m GONADS 2.000E-14 2.278E-11 2.655E-11 1.800E-15-1.000E+00 0.000E+00 0.000E+00 BREAST 2.290E-14 2.177E-11 2.537E-11 1.720E-15-1.000E+00 0.000E+00 0.000E+00 LUNGS 1.980E-14 2.139E-11 2.493E-11 1.690E-15-1.000E+00 0.000E+00 0.000E+00 RED MARR 1.910E-14 2.190E-11 2.552E-11 1.730E-15-1.000E+00 0.000E+00 0.000E+00 BONE SUR 3.500E-14 2.886E-11 3.363E-11 2.280E-15-1.000E+00 0.000E+00 0.000E+00 THYROID 2.040E-14 2.012E-11 2.345E-11 1.590E-15-1.000E+00 0.000E+00 0.000E+00 REMAINDER 1.890E-14 2.139E-11 2.493E-11 1.690E-15-1.000E+00 0.000E+00 0.000E+00 EFFECTIVE 2.040E-14 2.202E-11 2.567E-11 1.740E-15-1.000E+00 0.000E+00 0.000E+00 SKIN(FGR) 2.970E-14 5.607E-11 6.534E-11 4.430E-15-1.000E+00 0.000E+00 0.000E+00 Cs-138 GONADS 1.170E-13 2.788E-12 5.187E-11 9.740E-17-1.000E+00 3.280E-12 2.150E-09 BREAST 1.330E-13 2.662E-12 4.953E-11 9.300E-17-1.000E+00 4.020E-12 2.140E-09 LUNGS 1.190E-13 2.553E-12 4.750E-11 8.920E-17-1.000E+00 1.590E-10 2.140E-09 RED MARR 1.180E-13 2.619E-12 4.873E-11 9.150E-17-1.000E+00 3.950E-12 3.720E-09 BONE SUR 1.700E-13 3.635E-12 6.764E-11 1.270E-16-1.000E+00 3.550E-12 6.860E-09 THYROID 1.210E-13 2.599E-12 4.836E-11 9.080E-17-1.000E+00 3.570E-12 2.140E-09 REMAINDER 1.150E-13 2.542E-12 4.729E-11 8.880E-17-1.000E+00 2.060E-11 2.330E-09 EFFECTIVE 1.210E-13 2.665E-12 4.958E-11 9.310E-17-1.000E+00 2.740E-11 2.530E-09 SKIN(FGR) 2.170E-13 2.210E-10 4.111E-09 7.720E-15-1.000E+00 0.000E+00 0.000E+00 Cs-134m GONADS 9.300E-16 7.155E-14 1.436E-12 2.490E-18-1.000E+00 3.610E-12 8.050E-12 BREAST 1.120E-15 7.212E-14 1.447E-12 2.510E-18-1.000E+00 3.390E-12 7.980E-12 LUNGS 7.840E-16 5.689E-14 1.142E-12 1.980E-18-1.000E+00 6.400E-11 7.970E-12 RED MARR 6.810E-16 5.345E-14 1.073E-12 1.860E-18-1.000E+00 3.760E-12 1.080E-10 BONE SUR 2.610E-15 1.560E-13 3.131E-12 5.430E-18-1.000E+00 3.550E-12 1.610E-10 THYROID 8.880E-16 6.063E-14 1.217E-12 2.110E-18-1.000E+00 3.340E-12 7.970E-12 REMAINDER 7.450E-16 5.603E-14 1.124E-12 1.950E-18-1.000E+00 6.900E-12 8.250E-09 EFFECTIVE 9.050E-16 6.523E-14 1.309E-12 2.270E-18-1.000E+00 1.180E-11 2.500E-09

Numerical Applications Inc. Attachment 3 Page 62 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 SKIN(FGR) 2.880E-15 1.914E-10 3.841E-09 6.660E-15-1.000E+00 0.000E+00 0.000E+00 Rb-88 GONADS 3.260E-14 9.590E-15 2.014E-13 3.330E-19-1.000E+00 1.310E-12 5.040E-11 BREAST 3.670E-14 1.008E-14 2.116E-13 3.500E-19-1.000E+00 1.430E-12 5.040E-11 LUNGS 3.310E-14 6.307E-15 1.324E-13 2.190E-19-1.000E+00 1.470E-10 5.040E-11 RED MARR 3.300E-14 5.558E-15 1.167E-13 1.930E-19-1.000E+00 1.450E-12 6.450E-09 BONE SUR 4.620E-14 2.393E-14 5.025E-13 8.310E-19-1.000E+00 1.470E-12 1.390E-08 THYROID 3.370E-14 7.171E-15 1.506E-13 2.490E-19-1.000E+00 1.370E-12 5.040E-11 REMAINDER 3.210E-14 6.422E-15 1.348E-13 2.230E-19-1.000E+00 1.380E-11 6.700E-09 EFFECTIVE 3.360E-14 8.179E-15 1.717E-13 2.840E-19-1.000E+00 2.260E-11 3.230E-09 SKIN(FGR) 1.830E-13 4.032E-12 8.465E-11 1.400E-16-1.000E+00 0.000E+00 0.000E+00 Rb-89 GONADS 1.030E-13 2.155E-11 5.062E-11 1.026E-15-1.000E+00 1.340E-12 2.520E-10 BREAST 1.170E-13 2.059E-11 4.838E-11 9.806E-16-1.000E+00 1.730E-12 3.676E-11 LUNGS 1.040E-13 1.970E-11 4.626E-11 9.376E-16-1.000E+00 6.800E-11 1.055E-11 RED MARR 1.040E-13 2.011E-11 4.722E-11 9.570E-16-1.000E+00 2.020E-12 5.659E-11 BONE SUR 1.480E-13 2.852E-11 6.709E-11 1.360E-15-1.000E+00 2.540E-12 2.070E-11 THYROID 1.070E-13 2.035E-11 4.782E-11 9.693E-16-1.000E+00 1.610E-12 1.968E-12 REMAINDER 1.010E-13 1.948E-11 4.573E-11 9.268E-16-1.000E+00 8.140E-12 2.557E-09 EFFECTIVE 1.060E-13 2.057E-11 4.832E-11 9.793E-16-1.000E+00 1.160E-11 8.455E-10 SKIN(FGR) 1.870E-13 1.748E-10 3.987E-10 8.080E-15-1.000E+00 0.000E+00 0.000E+00 Sb-124 GONADS 8.890E-14 1.593E-11 1.830E-11 1.300E-15-1.000E+00 1.040E-09 8.180E-11 BREAST 1.010E-13 1.520E-11 1.745E-11 1.240E-15-1.000E+00 8.940E-10 1.700E-11 LUNGS 8.970E-14 1.483E-11 1.703E-11 1.210E-15-1.000E+00 4.140E-08 7.220E-12 RED MARR 8.850E-14 1.520E-11 1.745E-11 1.240E-15-1.000E+00 1.090E-09 2.290E-11 BONE SUR 1.340E-13 2.010E-11 2.308E-11 1.640E-15-1.000E+00 1.240E-09 8.490E-12 THYROID 9.150E-14 1.446E-11 1.661E-11 1.180E-15-1.000E+00 6.740E-10 1.300E-12 REMAINDER 8.660E-14 1.471E-11 1.689E-11 1.200E-15-1.000E+00 4.180E-09 1.720E-09 EFFECTIVE 9.150E-14 1.532E-11 1.759E-11 1.250E-15-1.000E+00 6.800E-09 5.430E-10 SKIN(FGR) 1.260E-13 2.280E-11 2.618E-11 1.860E-15-1.000E+00 0.000E+00 0.000E+00 Sb-125 GONADS 1.980E-14 1.586E-13 1.601E-12 5.750E-18-1.000E+00 3.600E-10 1.430E-14 BREAST 2.270E-14 1.578E-13 1.593E-12 5.720E-18-1.000E+00 4.160E-10 1.270E-14 LUNGS 1.950E-14 1.313E-13 1.326E-12 4.760E-18-1.000E+00 2.170E-08 1.260E-14 RED MARR 1.870E-14 1.261E-13 1.273E-12 4.570E-18-1.000E+00 5.350E-10 3.700E-13 BONE SUR 3.530E-14 3.228E-13 3.259E-12 1.170E-17-1.000E+00 9.780E-10 3.670E-13 THYROID 2.010E-14 1.385E-13 1.398E-12 5.020E-18-1.000E+00 3.240E-10 1.260E-14 REMAINDER 1.860E-14 1.291E-13 1.303E-12 4.680E-18-1.000E+00 1.450E-09 9.680E-09 EFFECTIVE 2.020E-14 1.468E-13 1.482E-12 5.320E-18-1.000E+00 3.300E-09 2.910E-09 SKIN(FGR) 2.650E-14 2.897E-10 2.924E-09 1.050E-14-1.000E+00 0.000E+00 0.000E+00 Sb-126 GONADS 1.350E-13 1.756E-13 3.546E-12 6.110E-18-1.000E+00 1.320E-09 3.540E-12 BREAST 1.530E-13 1.713E-13 3.459E-12 5.960E-18-1.000E+00 6.440E-10 5.540E-13 LUNGS 1.340E-13 1.526E-13 3.082E-12 5.310E-18-1.000E+00 1.380E-08 2.020E-13 RED MARR 1.300E-13 1.521E-13 3.070E-12 5.290E-18-1.000E+00 7.970E-10 6.590E-12 BONE SUR 2.220E-13 2.903E-13 5.862E-12 1.010E-17-1.000E+00 6.750E-10 6.130E-12 THYROID 1.370E-13 1.564E-13 3.157E-12 5.440E-18-1.000E+00 4.800E-10 1.290E-13 REMAINDER 1.280E-13 1.509E-13 3.047E-12 5.250E-18-1.000E+00 3.190E-09 8.570E-09 EFFECTIVE 1.370E-13 1.650E-13 3.332E-12 5.740E-18-1.000E+00 3.170E-09 2.570E-09 SKIN(FGR) 1.730E-13 1.989E-10 4.016E-09 6.920E-15-1.000E+00 0.000E+00 0.000E+00 Te-131 GONADS 1.990E-14 3.855E-12 4.872E-12 2.650E-16-1.000E+00 6.140E-12 1.960E-11 BREAST 2.280E-14 3.680E-12 4.652E-12 2.530E-16-1.000E+00 5.530E-12 3.550E-12 LUNGS 1.960E-14 3.535E-12 4.468E-12 2.430E-16-1.000E+00 2.540E-10 1.390E-12 RED MARR 1.880E-14 3.608E-12 4.560E-12 2.480E-16-1.000E+00 6.640E-12 4.910E-12 BONE SUR 3.800E-14 5.091E-12 6.435E-12 3.500E-16-1.000E+00 6.210E-12 1.750E-12 THYROID 2.030E-14 3.579E-12 4.523E-12 2.460E-16-1.000E+00 2.630E-09 1.770E-13 REMAINDER 1.870E-14 3.506E-12 4.431E-12 2.410E-16-1.000E+00 5.420E-11 1.700E-09 EFFECTIVE 2.040E-14 3.680E-12 4.652E-12 2.530E-16-1.000E+00 1.290E-10 5.150E-10 SKIN(FGR) 6.890E-14 2.022E-10 2.556E-10 1.390E-14-1.000E+00 0.000E+00 0.000E+00 Te-133 GONADS 4.490E-14 2.108E-12 4.989E-12 9.510E-17-1.000E+00 6.700E-13 2.200E-11 BREAST 5.100E-14 2.026E-12 4.794E-12 9.140E-17-1.000E+00 8.480E-13 3.130E-12 LUNGS 4.470E-14 1.937E-12 4.585E-12 8.740E-17-1.000E+00 4.390E-11 8.670E-13 RED MARR 4.360E-14 1.972E-12 4.669E-12 8.900E-17-1.000E+00 8.390E-13 4.930E-12 BONE SUR 7.500E-14 2.948E-12 6.977E-12 1.330E-16-1.000E+00 7.490E-13 1.730E-12 THYROID 4.590E-14 1.908E-12 4.516E-12 8.610E-17-1.000E+00 5.910E-10 1.260E-13 REMAINDER 4.290E-14 1.919E-12 4.543E-12 8.660E-17-1.000E+00 5.020E-12 4.090E-09 EFFECTIVE 4.600E-14 2.021E-12 4.784E-12 9.120E-17-1.000E+00 2.490E-11 1.230E-09 SKIN(FGR) 1.060E-13 2.726E-10 6.452E-10 1.230E-14-1.000E+00 0.000E+00 0.000E+00 Te-134 GONADS 4.160E-14 2.182E-11 4.421E-10 7.590E-16-1.000E+00 9.000E-12 8.160E-10

Numerical Applications Inc. Attachment 3 Page 63 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 BREAST 4.750E-14 2.084E-11 4.223E-10 7.250E-16-1.000E+00 8.720E-12 1.050E-10 LUNGS 4.100E-14 1.989E-11 4.030E-10 6.920E-16-1.000E+00 6.020E-11 2.340E-11 RED MARR 3.940E-14 2.030E-11 4.112E-10 7.060E-16-1.000E+00 9.300E-12 2.140E-10 BONE SUR 7.560E-14 2.875E-11 5.824E-10 1.000E-15-1.000E+00 8.580E-12 4.860E-10 THYROID 4.230E-14 2.076E-11 4.205E-10 7.220E-16-1.000E+00 5.540E-10 8.270E-12 REMAINDER 3.910E-14 1.963E-11 3.978E-10 6.830E-16-1.000E+00 1.880E-11 2.530E-09 EFFECTIVE 4.240E-14 2.078E-11 4.211E-10 7.230E-16-1.000E+00 3.440E-11 1.020E-09 SKIN(FGR) 6.350E-14 2.561E-11 5.190E-10 8.910E-16-1.000E+00 0.000E+00 0.000E+00 Te-125m GONADS 5.960E-16 2.179E-11 7.799E-11 9.253E-16-1.000E+00 7.930E-11 6.228E-10 BREAST 8.480E-16 2.083E-11 7.455E-11 8.846E-16-1.000E+00 7.080E-11 8.137E-11 LUNGS 2.230E-16 1.992E-11 7.127E-11 8.456E-16-1.000E+00 1.040E-08 1.770E-11 RED MARR 1.860E-16 2.034E-11 7.279E-11 8.634E-16-1.000E+00 1.150E-09 1.302E-10 BONE SUR 1.220E-15 2.881E-11 1.031E-10 1.224E-15-1.000E+00 1.180E-08 4.558E-11 THYROID 4.640E-16 2.061E-11 7.377E-11 8.755E-16-1.000E+00 3.870E-11 2.671E-12 REMAINDER 2.590E-16 1.966E-11 7.035E-11 8.345E-16-1.000E+00 6.750E-10 6.990E-09 EFFECTIVE 4.530E-16 2.078E-11 7.438E-11 8.824E-16-1.000E+00 1.970E-09 2.283E-09 SKIN(FGR) 1.940E-15 2.281E-10 8.148E-10 9.587E-15-1.000E+00 0.000E+00 0.000E+00 Te-133m GONADS 1.120E-13 2.253E-11 4.435E-10 7.850E-16-1.000E+00 8.970E-12 8.050E-10 BREAST 1.270E-13 2.150E-11 4.231E-10 7.490E-16-1.000E+00 7.820E-12 1.070E-10 LUNGS 1.120E-13 2.055E-11 4.045E-10 7.160E-16-1.000E+00 1.820E-10 2.740E-11 RED MARR 1.090E-13 2.101E-11 4.135E-10 7.320E-16-1.000E+00 8.320E-12 1.990E-10 BONE SUR 1.750E-13 2.957E-11 5.819E-10 1.030E-15-1.000E+00 6.940E-12 2.940E-10 THYROID 1.150E-13 2.144E-11 4.220E-10 7.470E-16-1.000E+00 2.610E-09 1.180E-11 REMAINDER 1.070E-13 2.032E-11 4.000E-10 7.080E-16-1.000E+00 4.140E-11 1.470E-09 EFFECTIVE 1.140E-13 2.147E-11 4.226E-10 7.480E-16-1.000E+00 1.170E-10 6.950E-10 SKIN(FGR) 1.740E-13 2.598E-11 5.112E-10 9.050E-16-1.000E+00 0.000E+00 0.000E+00 Ba-141 GONADS 4.060E-14 4.282E-12 4.403E-11 1.550E-16-1.000E+00 1.410E-12 2.180E-10 BREAST 4.630E-14 4.116E-12 4.233E-11 1.490E-16-1.000E+00 1.470E-12 3.430E-11 LUNGS 4.030E-14 3.867E-12 3.977E-11 1.400E-16-1.000E+00 1.160E-10 1.510E-11 RED MARR 3.910E-14 3.923E-12 4.034E-11 1.420E-16-1.000E+00 2.490E-12 8.320E-11 BONE SUR 7.170E-14 6.105E-12 6.278E-11 2.210E-16-1.000E+00 4.730E-12 6.320E-11 THYROID 4.150E-14 4.033E-12 4.147E-11 1.460E-16-1.000E+00 1.330E-12 1.030E-11 REMAINDER 3.870E-14 3.812E-12 3.920E-11 1.380E-16-1.000E+00 2.270E-11 4.280E-09 EFFECTIVE 4.160E-14 4.061E-12 4.176E-11 1.470E-16-1.000E+00 2.180E-11 1.360E-09 SKIN(FGR) 1.070E-13 1.039E-10 1.068E-09 3.760E-15-1.000E+00 0.000E+00 0.000E+00 Ba-137m GONADS 2.820E-14 2.334E-12 3.877E-12 1.240E-16-1.000E+00 0.000E+00 9.750E-12 BREAST 3.220E-14 2.258E-12 3.752E-12 1.200E-16-1.000E+00 0.000E+00 3.570E-12 LUNGS 2.800E-14 2.127E-12 3.533E-12 1.130E-16-1.000E+00 0.000E+00 3.140E-12 RED MARR 2.730E-14 2.070E-12 3.439E-12 1.100E-16-1.000E+00 0.000E+00 6.290E-12 BONE SUR 4.630E-14 5.383E-12 8.942E-12 2.860E-16-1.000E+00 0.000E+00 4.060E-12 THYROID 2.880E-14 2.145E-12 3.564E-12 1.140E-16-1.000E+00 0.000E+00 8.460E-11 REMAINDER 2.680E-14 2.070E-12 3.439E-12 1.100E-16-1.000E+00 0.000E+00 3.340E-11 EFFECTIVE 2.880E-14 2.277E-12 3.783E-12 1.210E-16-1.000E+00 0.000E+00 1.680E-11 SKIN(FGR) 3.730E-14 2.710E-12 4.502E-12 1.440E-16-1.000E+00 0.000E+00 0.000E+00 Pd-109 GONADS 2.710E-16 1.404E-11 2.783E-10 4.892E-16-1.000E+00 2.130E-12 5.720E-10 BREAST 3.520E-16 1.350E-11 2.677E-10 4.705E-16-1.000E+00 5.110E-13 1.200E-10 LUNGS 1.940E-16 1.273E-11 2.522E-10 4.432E-16-1.000E+00 1.200E-09 7.310E-11 RED MARR 1.740E-16 1.287E-11 2.551E-10 4.483E-16-1.000E+00 9.820E-13 1.660E-10 BONE SUR 7.020E-16 1.958E-11 3.882E-10 6.823E-16-1.000E+00 9.580E-13 9.631E-11 THYROID 2.460E-16 1.331E-11 2.639E-10 4.638E-16-1.000E+00 1.550E-13 6.250E-11 REMAINDER 1.920E-16 1.248E-11 2.472E-10 4.346E-16-1.000E+00 5.040E-10 2.110E-09 EFFECTIVE 2.510E-16 1.332E-11 2.641E-10 4.642E-16-1.000E+00 2.960E-10 8.271E-10 SKIN(FGR) 2.150E-14 1.785E-11 3.543E-10 6.229E-16-1.000E+00 0.000E+00 0.000E+00 Rh-106 GONADS 1.010E-14 1.327E-11 1.861E-11 8.070E-16-1.000E+00 0.000E+00 9.670E-11 BREAST 1.160E-14 1.271E-11 1.783E-11 7.730E-16-1.000E+00 0.000E+00 1.590E-11 LUNGS 1.010E-14 1.210E-11 1.697E-11 7.360E-16-1.000E+00 0.000E+00 6.210E-12 RED MARR 9.750E-15 1.230E-11 1.725E-11 7.480E-16-1.000E+00 0.000E+00 2.350E-11 BONE SUR 1.720E-14 1.809E-11 2.537E-11 1.100E-15-1.000E+00 0.000E+00 8.890E-12 THYROID 1.030E-14 1.260E-11 1.766E-11 7.660E-16-1.000E+00 0.000E+00 1.820E-12 REMAINDER 9.630E-15 1.189E-11 1.667E-11 7.230E-16-1.000E+00 0.000E+00 8.540E-10 EFFECTIVE 1.040E-14 1.265E-11 1.773E-11 7.690E-16-1.000E+00 0.000E+00 2.870E-10 SKIN(FGR) 1.090E-13 7.368E-11 1.033E-10 4.480E-15-1.000E+00 0.000E+00 0.000E+00 Rh-103m GONADS 1.250E-17 6.411E-12 1.340E-10 2.230E-16-1.000E+00 8.910E-14 1.640E-09 BREAST 2.150E-17 6.152E-12 1.286E-10 2.140E-16-1.000E+00 8.800E-14 1.440E-09 LUNGS 1.870E-18 5.836E-12 1.220E-10 2.030E-16-1.000E+00 7.750E-12 1.420E-09 RED MARR 2.820E-18 5.893E-12 1.232E-10 2.050E-16-1.000E+00 8.840E-14 1.460E-09

Numerical Applications Inc. Attachment 3 Page 64 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 BONE SUR 1.760E-17 8.883E-12 1.856E-10 3.090E-16-1.000E+00 8.730E-14 1.430E-09 THYROID 8.550E-18 6.066E-12 1.268E-10 2.110E-16-1.000E+00 8.490E-14 1.410E-09 REMAINDER 3.680E-18 5.721E-12 1.196E-10 1.990E-16-1.000E+00 1.340E-12 2.110E-08 EFFECTIVE 8.800E-18 6.095E-12 1.274E-10 2.120E-16-1.000E+00 1.380E-12 7.400E-09 SKIN(FGR) 4.490E-17 4.082E-10 8.531E-09 1.420E-14-1.000E+00 0.000E+00 0.000E+00 Tc-101 GONADS 1.570E-14 2.127E-12 1.411E-11 7.980E-17-1.000E+00 2.500E-13 5.800E-11 BREAST 1.800E-14 2.063E-12 1.369E-11 7.740E-17-1.000E+00 3.030E-13 8.970E-12 LUNGS 1.540E-14 1.935E-12 1.284E-11 7.260E-17-1.000E+00 2.830E-11 3.860E-12 RED MARR 1.460E-14 1.946E-12 1.291E-11 7.300E-17-1.000E+00 3.190E-13 1.470E-11 BONE SUR 3.210E-14 3.332E-12 2.210E-11 1.250E-16-1.000E+00 2.800E-13 6.750E-12 THYROID 1.590E-14 1.983E-12 1.316E-11 7.440E-17-1.000E+00 7.720E-12 2.910E-12 REMAINDER 1.470E-14 1.885E-12 1.250E-11 7.070E-17-1.000E+00 3.520E-12 1.270E-09 EFFECTIVE 1.610E-14 2.031E-12 1.347E-11 7.620E-17-1.000E+00 4.840E-12 3.990E-10 SKIN(FGR) 4.770E-14 4.691E-12 3.112E-11 1.760E-16-1.000E+00 0.000E+00 0.000E+00 Eu-154 GONADS 6.000E-14 1.985E-11 2.441E-10 7.100E-16-1.000E+00 1.170E-08 6.140E-10 BREAST 6.810E-14 1.904E-11 2.341E-10 6.810E-16-1.000E+00 1.550E-08 7.600E-11 LUNGS 5.990E-14 1.809E-11 2.224E-10 6.470E-16-1.000E+00 7.920E-08 1.570E-11 RED MARR 5.870E-14 1.834E-11 2.255E-10 6.560E-16-1.000E+00 1.060E-07 1.330E-10 BONE SUR 9.430E-14 2.720E-11 3.345E-10 9.730E-16-1.000E+00 5.230E-07 5.240E-11 THYROID 6.150E-14 1.884E-11 2.317E-10 6.740E-16-1.000E+00 7.140E-09 4.640E-12 REMAINDER 5.750E-14 1.775E-11 2.183E-10 6.350E-16-1.000E+00 1.130E-07 5.870E-09 EFFECTIVE 6.140E-14 1.890E-11 2.324E-10 6.760E-16-1.000E+00 7.730E-08 1.950E-09 SKIN(FGR) 8.290E-14 7.967E-11 9.799E-10 2.850E-15-1.000E+00 0.000E+00 0.000E+00 Eu-155 GONADS 2.490E-15 2.336E-11 3.231E-11 1.440E-15-1.000E+00 3.560E-10 1.510E-10 BREAST 2.950E-15 2.222E-11 3.074E-11 1.370E-15-1.000E+00 6.140E-10 2.560E-11 LUNGS 2.220E-15 2.141E-11 2.962E-11 1.320E-15-1.000E+00 1.190E-08 9.390E-12 RED MARR 1.850E-15 2.190E-11 3.029E-11 1.350E-15-1.000E+00 1.430E-08 3.670E-11 BONE SUR 8.090E-15 3.033E-11 4.196E-11 1.870E-15-1.000E+00 1.520E-07 1.340E-11 THYROID 2.410E-15 2.174E-11 3.007E-11 1.340E-15-1.000E+00 2.400E-10 1.470E-12 REMAINDER 2.070E-15 2.125E-11 2.939E-11 1.310E-15-1.000E+00 1.110E-08 1.450E-09 EFFECTIVE 2.490E-15 2.238E-11 3.096E-11 1.380E-15-1.000E+00 1.120E-08 4.840E-10 SKIN(FGR) 3.390E-15 8.273E-11 1.144E-10 5.100E-15-1.000E+00 0.000E+00 0.000E+00 Eu-156 GONADS 6.570E-14 1.191E-13 2.661E-13 5.480E-18-1.000E+00 6.120E-10 4.020E-12 BREAST 7.420E-14 1.158E-13 2.588E-13 5.330E-18-1.000E+00 3.640E-10 3.000E-12 LUNGS 6.630E-14 1.060E-13 2.370E-13 4.880E-18-1.000E+00 1.840E-08 2.890E-12 RED MARR 6.560E-14 1.058E-13 2.365E-13 4.870E-18-1.000E+00 1.140E-09 6.570E-12 BONE SUR 9.580E-14 1.862E-13 4.162E-13 8.570E-18-1.000E+00 2.760E-09 6.460E-12 THYROID 6.780E-14 1.106E-13 2.472E-13 5.090E-18-1.000E+00 2.160E-10 2.860E-12 REMAINDER 6.410E-14 1.036E-13 2.316E-13 4.770E-18-1.000E+00 3.910E-09 6.130E-10 EFFECTIVE 6.750E-14 1.125E-13 2.515E-13 5.180E-18-1.000E+00 3.820E-09 1.870E-10 SKIN(FGR) 9.980E-14 1.173E-11 2.622E-11 5.400E-16-1.000E+00 0.000E+00 0.000E+00 La-143 GONADS 5.040E-15 4.689E-13 9.642E-12 1.630E-17-1.000E+00 6.530E-13 1.250E-10 BREAST 5.700E-15 5.150E-13 1.059E-11 1.790E-17-1.000E+00 3.200E-13 9.740E-11 LUNGS 5.070E-15 1.602E-13 3.295E-12 5.570E-18-1.000E+00 1.060E-10 9.620E-11 RED MARR 5.010E-15 1.249E-13 2.567E-12 4.340E-18-1.000E+00 7.300E-13 5.430E-09 BONE SUR 7.590E-15 9.005E-13 1.852E-11 3.130E-17-1.000E+00 7.290E-13 2.070E-08 THYROID 5.190E-15 2.779E-13 5.714E-12 9.660E-18-1.000E+00 2.440E-13 9.430E-11 REMAINDER 4.900E-15 1.999E-13 4.111E-12 6.950E-18-1.000E+00 1.050E-11 2.980E-09 EFFECTIVE 5.180E-15 3.251E-13 6.684E-12 1.130E-17-1.000E+00 1.620E-11 2.230E-09 SKIN(FGR) 9.640E-14 1.496E-12 3.076E-11 5.200E-17-1.000E+00 0.000E+00 0.000E+00 Nb-97 GONADS 3.110E-14 3.889E-13 3.922E-13 6.510E-17-1.000E+00 8.650E-13 1.590E-12 BREAST 3.550E-14 3.800E-13 3.832E-13 6.360E-17-1.000E+00 1.120E-12 6.050E-13 LUNGS 3.100E-14 3.298E-13 3.326E-13 5.520E-17-1.000E+00 1.560E-10 4.910E-13 RED MARR 3.010E-14 3.298E-13 3.326E-13 5.520E-17-1.000E+00 1.140E-12 7.640E-13 BONE SUR 5.110E-14 5.753E-13 5.802E-13 9.630E-17-1.000E+00 8.260E-13 5.400E-13 THYROID 3.180E-14 3.525E-13 3.555E-13 5.900E-17-1.000E+00 9.200E-13 3.360E-13 REMAINDER 2.960E-14 3.262E-13 3.289E-13 5.460E-17-1.000E+00 1.050E-11 1.790E-10 EFFECTIVE 3.180E-14 3.590E-13 3.621E-13 6.010E-17-1.000E+00 2.240E-11 5.450E-11 SKIN(FGR) 6.510E-14 3.429E-11 3.458E-11 5.740E-15-1.000E+00 0.000E+00 0.000E+00 Nb-95m GONADS 2.880E-15 2.206E-12 4.799E-11 8.561E-17-1.000E+00 4.960E-11 2.420E-10 BREAST 3.310E-15 2.181E-12 4.739E-11 8.454E-17-1.000E+00 4.530E-11 1.664E-10 LUNGS 2.770E-15 1.741E-12 3.815E-11 6.808E-17-1.000E+00 3.070E-09 1.593E-10 RED MARR 2.590E-15 1.729E-12 3.793E-11 6.768E-17-1.000E+00 5.870E-11 3.500E-09 BONE SUR 6.600E-15 3.287E-12 7.147E-11 1.275E-16-1.000E+00 6.610E-11 7.990E-09 THYROID 2.890E-15 1.923E-12 4.201E-11 7.495E-17-1.000E+00 3.860E-11 1.572E-10 REMAINDER 2.630E-15 1.746E-12 3.822E-11 6.819E-17-1.000E+00 8.690E-10 7.196E-09

Numerical Applications Inc. Attachment 3 Page 65 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 EFFECTIVE 2.930E-15 1.974E-12 4.308E-11 7.686E-17-1.000E+00 6.590E-10 2.925E-09 SKIN(FGR) 1.120E-14 1.501E-10 3.360E-09 6.001E-15-1.000E+00 0.000E+00 0.000E+00 Pm-147 GONADS 7.480E-19 4.020E-11 2.343E-10 1.535E-15-1.000E+00 8.250E-15 7.415E-10 BREAST 9.560E-19 3.853E-11 2.246E-10 1.472E-15-1.000E+00 3.600E-14 1.361E-10 LUNGS 5.450E-19 3.657E-11 2.131E-10 1.397E-15-1.000E+00 7.740E-08 6.335E-11 RED MARR 4.460E-19 3.736E-11 2.178E-10 1.427E-15-1.000E+00 1.610E-09 2.435E-10 BONE SUR 2.180E-18 5.467E-11 3.189E-10 2.090E-15-1.000E+00 2.010E-08 3.248E-10 THYROID 6.750E-19 3.741E-11 2.181E-10 1.429E-15-1.000E+00 1.980E-14 4.383E-08 REMAINDER 5.260E-19 3.626E-11 2.113E-10 1.385E-15-1.000E+00 1.560E-09 3.153E-09 EFFECTIVE 6.930E-19 3.825E-11 2.229E-10 1.461E-15-1.000E+00 1.060E-08 2.514E-09 SKIN(FGR) 8.110E-16 1.033E-10 6.188E-10 4.056E-15-1.000E+00 0.000E+00 0.000E+00 Pm-148 GONADS 2.810E-14 6.812E-12 7.706E-11 2.450E-16-1.000E+00 2.120E-10 5.410E-10 BREAST 3.190E-14 6.756E-12 7.643E-11 2.430E-16-1.000E+00 7.190E-11 3.500E-10 LUNGS 2.830E-14 5.727E-12 6.479E-11 2.060E-16-1.000E+00 1.370E-08 3.300E-10 RED MARR 2.790E-14 5.588E-12 6.322E-11 2.010E-16-1.000E+00 1.070E-10 4.440E-10 BONE SUR 4.240E-14 1.273E-11 1.441E-10 4.580E-16-1.000E+00 7.080E-11 8.300E-10 THYROID 2.890E-14 5.978E-12 6.762E-11 2.150E-16-1.000E+00 3.820E-11 5.950E-08 REMAINDER 2.730E-14 5.644E-12 6.385E-11 2.030E-16-1.000E+00 4.100E-09 1.490E-09 EFFECTIVE 2.890E-14 6.339E-12 7.171E-11 2.280E-16-1.000E+00 2.950E-09 2.540E-09 SKIN(FGR) 7.970E-14 8.313E-12 9.405E-11 2.990E-16-1.000E+00 0.000E+00 0.000E+00 Pm-149 GONADS 5.300E-16 1.119E-11 1.789E-10 3.940E-16-1.000E+00 3.610E-12 4.070E-11 BREAST 6.070E-16 1.082E-11 1.730E-10 3.810E-16-1.000E+00 8.200E-13 1.210E-10 LUNGS 5.170E-16 1.016E-11 1.626E-10 3.580E-16-1.000E+00 3.120E-09 1.020E-10 RED MARR 4.890E-16 1.022E-11 1.635E-10 3.600E-16-1.000E+00 5.530E-12 9.440E-11 BONE SUR 1.100E-15 1.675E-11 2.679E-10 5.900E-16-1.000E+00 5.010E-12 8.720E-11 THYROID 5.360E-16 1.053E-11 1.685E-10 3.710E-16-1.000E+00 3.310E-13 4.760E-07 REMAINDER 4.910E-16 9.908E-12 1.585E-10 3.490E-16-1.000E+00 1.390E-09 1.570E-10 EFFECTIVE 5.410E-16 1.067E-11 1.707E-10 3.760E-16-1.000E+00 7.930E-10 1.440E-08 SKIN(FGR) 2.190E-14 1.825E-11 2.920E-10 6.430E-16-1.000E+00 0.000E+00 0.000E+00 Pm-151 GONADS 1.480E-14 2.523E-11 2.771E-11 2.320E-15-1.000E+00 7.170E-11 2.330E-11 BREAST 1.700E-14 2.414E-11 2.652E-11 2.220E-15-1.000E+00 1.590E-11 2.520E-11 LUNGS 1.440E-14 2.305E-11 2.532E-11 2.120E-15-1.000E+00 1.640E-09 2.640E-11 RED MARR 1.370E-14 2.360E-11 2.592E-11 2.170E-15-1.000E+00 2.720E-11 2.460E-11 BONE SUR 2.990E-14 3.327E-11 3.655E-11 3.060E-15-1.000E+00 1.860E-11 2.190E-11 THYROID 1.500E-14 2.381E-11 2.616E-11 2.190E-15-1.000E+00 6.180E-12 3.870E-09 REMAINDER 1.370E-14 2.283E-11 2.509E-11 2.100E-15-1.000E+00 8.390E-10 1.650E-10 EFFECTIVE 1.510E-14 2.403E-11 2.640E-11 2.210E-15-1.000E+00 4.730E-10 1.820E-10 SKIN(FGR) 3.320E-14 8.199E-11 9.007E-11 7.540E-15-1.000E+00 0.000E+00 0.000E+00 Pm-148m GONADS 9.470E-14 1.585E-11 6.748E-11 6.270E-16-1.000E+00 1.190E-09 3.630E-11 BREAST 1.080E-13 1.519E-11 6.468E-11 6.010E-16-1.000E+00 1.240E-09 4.680E-11 LUNGS 9.420E-14 1.446E-11 6.156E-11 5.720E-16-1.000E+00 3.590E-08 4.530E-11 RED MARR 9.140E-14 1.466E-11 6.242E-11 5.800E-16-1.000E+00 1.360E-09 4.300E-11 BONE SUR 1.580E-13 2.161E-11 9.202E-11 8.550E-16-1.000E+00 1.360E-09 4.070E-11 THYROID 9.680E-14 1.502E-11 6.393E-11 5.940E-16-1.000E+00 1.050E-09 9.100E-08 REMAINDER 9.010E-14 1.418E-11 6.038E-11 5.610E-16-1.000E+00 3.580E-09 1.550E-10 EFFECTIVE 9.680E-14 1.509E-11 6.425E-11 5.970E-16-1.000E+00 6.100E-09 2.800E-09 SKIN(FGR) 1.180E-13 1.150E-10 4.897E-10 4.550E-15-1.000E+00 0.000E+00 0.000E+00 Pr-144 GONADS 1.900E-15 1.200E-11 1.202E-11 2.640E-15-1.000E+00 2.410E-15 1.100E-11 BREAST 2.150E-15 1.145E-11 1.147E-11 2.520E-15-1.000E+00 1.050E-14 1.170E-11 LUNGS 1.900E-15 1.100E-11 1.102E-11 2.420E-15-1.000E+00 9.400E-11 1.260E-11 RED MARR 1.870E-15 1.127E-11 1.129E-11 2.480E-15-1.000E+00 1.380E-14 1.090E-11 BONE SUR 2.990E-15 1.568E-11 1.571E-11 3.450E-15-1.000E+00 1.470E-14 9.320E-12 THYROID 1.950E-15 1.127E-11 1.129E-11 2.480E-15-1.000E+00 8.470E-15 6.210E-10 REMAINDER 1.840E-15 1.091E-11 1.093E-11 2.400E-15-1.000E+00 1.400E-12 1.340E-10 EFFECTIVE 1.950E-15 1.150E-11 1.152E-11 2.530E-15-1.000E+00 1.170E-11 6.660E-11 SKIN(FGR) 8.430E-14 4.477E-11 4.485E-11 9.850E-15-1.000E+00 0.000E+00 0.000E+00 Pr-144m GONADS 3.250E-16 3.113E-11 5.489E-11 1.599E-15-1.000E+00 0.000E+00 3.610E-11 BREAST 4.200E-16 2.971E-11 5.240E-11 1.526E-15-1.000E+00 0.000E+00 3.850E-11 LUNGS 2.000E-16 2.886E-11 5.089E-11 1.482E-15-1.000E+00 0.000E+00 3.750E-11 RED MARR 1.560E-16 2.965E-11 5.228E-11 1.523E-15-1.000E+00 0.000E+00 3.650E-11 BONE SUR 8.160E-16 3.983E-11 7.024E-11 2.046E-15-1.000E+00 0.000E+00 3.360E-11 THYROID 2.810E-16 2.852E-11 5.030E-11 1.465E-15-1.000E+00 0.000E+00 1.790E-08 REMAINDER 1.980E-16 2.883E-11 5.084E-11 1.481E-15-1.000E+00 0.000E+00 1.540E-10 EFFECTIVE 2.790E-16 2.989E-11 5.271E-11 1.535E-15-1.000E+00 0.000E+00 6.080E-10 SKIN(FGR) 5.080E-16 9.826E-11 1.733E-10 5.047E-15-1.000E+00 0.000E+00 0.000E+00 Sm-153

Numerical Applications Inc. Attachment 3 Page 66 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 GONADS 2.330E-15 1.465E-12 2.052E-11 5.200E-17-1.000E+00 2.360E-11 0.000E+00 BREAST 2.820E-15 1.505E-12 2.107E-11 5.340E-17-1.000E+00 5.670E-12 0.000E+00 LUNGS 1.970E-15 1.045E-12 1.464E-11 3.710E-17-1.000E+00 2.050E-09 0.000E+00 RED MARR 1.620E-15 8.791E-13 1.231E-11 3.120E-17-1.000E+00 6.660E-11 0.000E+00 BONE SUR 7.290E-15 4.254E-12 5.958E-11 1.510E-16-1.000E+00 1.570E-10 0.000E+00 THYROID 2.220E-15 1.181E-12 1.653E-11 4.190E-17-1.000E+00 1.510E-12 0.000E+00 REMAINDER 1.850E-15 1.042E-12 1.460E-11 3.700E-17-1.000E+00 8.840E-10 0.000E+00 EFFECTIVE 2.280E-15 1.299E-12 1.819E-11 4.610E-17-1.000E+00 5.310E-10 0.000E+00 SKIN(FGR) 1.450E-14 1.953E-12 2.734E-11 6.930E-17-1.000E+00 0.000E+00 0.000E+00 Y-94 GONADS 5.490E-14 5.455E-12 1.194E-11 2.530E-16-1.000E+00 1.230E-13 0.000E+00 BREAST 6.210E-14 5.325E-12 1.166E-11 2.470E-16-1.000E+00 4.400E-13 0.000E+00 LUNGS 5.500E-14 4.959E-12 1.086E-11 2.300E-16-1.000E+00 1.480E-10 0.000E+00 RED MARR 5.420E-14 4.959E-12 1.086E-11 2.300E-16-1.000E+00 4.180E-13 0.000E+00 BONE SUR 8.220E-14 9.120E-12 1.997E-11 4.230E-16-1.000E+00 3.280E-13 0.000E+00 THYROID 5.650E-14 5.023E-12 1.100E-11 2.330E-16-1.000E+00 4.120E-13 0.000E+00 REMAINDER 5.300E-14 4.829E-12 1.058E-11 2.240E-16-1.000E+00 3.080E-12 0.000E+00 EFFECTIVE 5.620E-14 5.217E-12 1.142E-11 2.420E-16-1.000E+00 1.890E-11 0.000E+00 SKIN(FGR) 1.800E-13 4.506E-11 9.867E-11 2.090E-15-1.000E+00 0.000E+00 0.000E+00 Y-95 GONADS 4.650E-14 4.607E-11 9.646E-10 1.600E-15-1.000E+00 1.070E-13 2.060E-08 BREAST 5.190E-14 4.406E-11 9.224E-10 1.530E-15-1.000E+00 3.170E-13 1.720E-08 LUNGS 4.720E-14 4.204E-11 8.802E-10 1.460E-15-1.000E+00 8.040E-11 1.760E-08 RED MARR 4.730E-14 4.262E-11 8.922E-10 1.480E-15-1.000E+00 3.200E-13 1.870E-08 BONE SUR 6.410E-14 6.105E-11 1.278E-09 2.120E-15-1.000E+00 3.790E-13 1.740E-08 THYROID 4.840E-14 4.377E-11 9.163E-10 1.520E-15-1.000E+00 2.790E-13 1.760E-08 REMAINDER 4.590E-14 4.147E-11 8.681E-10 1.440E-15-1.000E+00 1.250E-12 2.210E-08 EFFECTIVE 4.790E-14 4.377E-11 9.163E-10 1.520E-15-1.000E+00 1.020E-11 1.980E-08 SKIN(FGR) 1.590E-13 6.249E-11 1.308E-09 2.170E-15-1.000E+00 0.000E+00 0.000E+00 Y-91m GONADS 2.490E-14 6.223E-11 1.102E-09 2.180E-15-1.000E+00 3.210E-13 3.040E-09 BREAST 2.850E-14 5.966E-11 1.056E-09 2.090E-15-1.000E+00 6.080E-13 2.650E-09 LUNGS 2.480E-14 5.710E-11 1.011E-09 2.000E-15-1.000E+00 7.000E-11 2.620E-09 RED MARR 2.390E-14 5.824E-11 1.031E-09 2.040E-15-1.000E+00 7.740E-13 2.950E-09 BONE SUR 4.280E-14 8.422E-11 1.491E-09 2.950E-15-1.000E+00 6.210E-13 2.710E-09 THYROID 2.540E-14 5.852E-11 1.036E-09 2.050E-15-1.000E+00 5.020E-13 2.740E-09 REMAINDER 2.370E-14 5.652E-11 1.001E-09 1.980E-15-1.000E+00 3.740E-12 3.520E-09 EFFECTIVE 2.550E-14 5.966E-11 1.056E-09 2.090E-15-1.000E+00 9.820E-12 3.040E-09 SKIN(FGR) 3.110E-14 7.251E-11 1.284E-09 2.540E-15-1.000E+00 0.000E+00 0.000E+00 Br-82 GONADS 1.270E-13 1.669E-11 3.530E-10 5.840E-16-1.000E+00 1.690E-10 1.390E-08 BREAST 1.440E-13 1.596E-11 3.376E-10 5.585E-16-1.000E+00 2.100E-10 1.240E-08 LUNGS 1.270E-13 1.517E-11 3.209E-10 5.309E-16-1.000E+00 1.680E-09 1.270E-08 RED MARR 1.240E-13 1.542E-11 3.260E-10 5.394E-16-1.000E+00 2.180E-10 1.320E-08 BONE SUR 1.990E-13 2.238E-11 4.734E-10 7.832E-16-1.000E+00 1.920E-10 1.260E-08 THYROID 1.300E-13 1.588E-11 3.358E-10 5.556E-16-1.000E+00 2.060E-10 1.260E-08 REMAINDER 1.220E-13 1.490E-11 3.152E-10 5.215E-16-1.000E+00 3.310E-10 1.450E-08 EFFECTIVE 1.300E-13 1.585E-11 3.353E-10 5.546E-16-1.000E+00 4.130E-10 1.350E-08 SKIN(FGR) 1.540E-13 5.253E-11 1.110E-09 1.836E-15-1.000E+00 0.000E+00 0.000E+00 Br-83 GONADS 3.740E-16 3.368E-13 3.429E-13 4.790E-17-1.000E+00 1.130E-12 1.560E-12 BREAST 4.290E-16 3.297E-13 3.357E-13 4.690E-17-1.000E+00 1.140E-12 5.170E-13 LUNGS 3.690E-16 3.002E-13 3.057E-13 4.270E-17-1.000E+00 1.820E-10 3.890E-13 RED MARR 3.540E-16 2.932E-13 2.985E-13 4.170E-17-1.000E+00 1.140E-12 8.590E-13 BONE SUR 6.750E-16 6.841E-13 6.965E-13 9.730E-17-1.000E+00 1.140E-12 4.380E-13 THYROID 3.800E-16 3.044E-13 3.100E-13 4.330E-17-1.000E+00 1.140E-12 2.660E-13 REMAINDER 3.520E-16 2.932E-13 2.985E-13 4.170E-17-1.000E+00 5.310E-12 3.570E-10 EFFECTIVE 3.820E-16 3.227E-13 3.286E-13 4.590E-17-1.000E+00 2.410E-11 1.080E-10 SKIN(FGR) 1.850E-14 7.241E-11 7.373E-11 1.030E-14-1.000E+00 0.000E+00 0.000E+00 Br-84 GONADS 9.160E-14 5.451E-12 9.607E-11 1.910E-16-1.000E+00 2.840E-12 9.960E-10 BREAST 1.020E-13 5.280E-12 9.305E-11 1.850E-16-1.000E+00 3.310E-12 1.590E-10 LUNGS 9.270E-14 4.852E-12 8.550E-11 1.700E-16-1.000E+00 1.560E-10 6.630E-11 RED MARR 9.260E-14 4.880E-12 8.601E-11 1.710E-16-1.000E+00 3.270E-12 4.390E-10 BONE SUR 1.280E-13 8.020E-12 1.413E-10 2.810E-16-1.000E+00 2.990E-12 5.530E-10 THYROID 9.500E-14 5.109E-12 9.003E-11 1.790E-16-1.000E+00 3.120E-12 5.250E-11 REMAINDER 8.990E-14 4.766E-12 8.399E-11 1.670E-16-1.000E+00 1.870E-11 7.370E-09 EFFECTIVE 9.410E-14 5.137E-12 9.053E-11 1.800E-16-1.000E+00 2.610E-11 2.560E-09 SKIN(FGR) 1.880E-13 5.565E-11 9.808E-10 1.950E-15-1.000E+00 0.000E+00 0.000E+00 Am-242 GONADS 6.090E-16 6.027E-11 4.425E-10 2.240E-15-1.000E+00 1.940E-09 1.340E-09 BREAST 7.300E-16 5.758E-11 4.228E-10 2.140E-15-1.000E+00 2.940E-12 1.800E-10 LUNGS 5.510E-16 5.596E-11 4.109E-10 2.080E-15-1.000E+00 5.200E-08 4.010E-11

Numerical Applications Inc. Attachment 3 Page 67 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 RED MARR 4.770E-16 5.731E-11 4.208E-10 2.130E-15-1.000E+00 1.320E-08 2.810E-10 BONE SUR 1.880E-15 7.776E-11 5.709E-10 2.890E-15-1.000E+00 1.650E-07 9.770E-11 THYROID 5.940E-16 5.462E-11 4.010E-10 2.030E-15-1.000E+00 2.520E-12 6.400E-12 REMAINDER 5.180E-16 5.569E-11 4.089E-10 2.070E-15-1.000E+00 8.540E-09 6.260E-09 EFFECTIVE 6.150E-16 5.812E-11 4.267E-10 2.160E-15-1.000E+00 1.580E-08 2.280E-09 SKIN(FGR) 8.200E-15 2.217E-10 1.628E-09 8.240E-15-1.000E+00 0.000E+00 0.000E+00 Np-238 GONADS 2.660E-14 7.315E-13 9.675E-13 4.740E-17-1.000E+00 1.990E-09 3.770E-12 BREAST 3.020E-14 7.007E-13 9.267E-13 4.540E-17-1.000E+00 4.180E-11 7.070E-13 LUNGS 2.650E-14 6.713E-13 8.879E-13 4.350E-17-1.000E+00 3.470E-09 2.720E-13 RED MARR 2.610E-14 6.852E-13 9.063E-13 4.440E-17-1.000E+00 1.690E-08 1.070E-12 BONE SUR 3.990E-14 9.923E-13 1.312E-12 6.430E-17-1.000E+00 2.100E-07 6.060E-13 THYROID 2.730E-14 6.590E-13 8.716E-13 4.270E-17-1.000E+00 2.450E-11 5.290E-14 REMAINDER 2.550E-14 6.682E-13 8.838E-13 4.330E-17-1.000E+00 2.550E-09 1.240E-09 EFFECTIVE 2.720E-14 7.007E-13 9.267E-13 4.540E-17-1.000E+00 1.000E-08 3.740E-10 SKIN(FGR) 4.310E-14 1.667E-10 2.204E-10 1.080E-14-1.000E+00 0.000E+00 0.000E+00 Pu-243 GONADS 1.020E-15 1.978E-11 2.034E-11 2.540E-15-1.000E+00 1.670E-12 6.990E-11 BREAST 1.210E-15 1.885E-11 1.938E-11 2.420E-15-1.000E+00 2.750E-13 1.540E-11 LUNGS 9.280E-16 1.846E-11 1.898E-11 2.370E-15-1.000E+00 2.270E-10 8.400E-12 RED MARR 7.840E-16 1.900E-11 1.954E-11 2.440E-15-1.000E+00 5.770E-12 1.930E-11 BONE SUR 3.230E-15 2.484E-11 2.554E-11 3.190E-15-1.000E+00 6.530E-11 7.400E-12 THYROID 9.910E-16 1.768E-11 1.818E-11 2.270E-15-1.000E+00 1.130E-13 1.160E-12 REMAINDER 8.660E-16 1.853E-11 1.906E-11 2.380E-15-1.000E+00 4.690E-11 5.200E-10 EFFECTIVE 1.030E-15 1.916E-11 1.970E-11 2.460E-15-1.000E+00 4.440E-11 1.790E-10 SKIN(FGR) 8.150E-15 9.111E-11 9.368E-11 1.170E-14-1.000E+00 0.000E+00 0.000E+00

Numerical Applications Inc. Attachment 4 Page 68 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Palisades MSLB Noble Gas Dose (pal_MSLB_ng_db_ast.out)

RADTRAD-NAI Version 1.1a(QA) run on May 26, 2006 at 14:06:58 File information Plant file name = AST/MSLB/pal_MSLB_ng_db_ast.psf Inventory file name = AST/MSLB/pal_mslb_db_ast.nif Scenario file name = AST/MSLB/pal_MSLB_ng_db_ast.psf Release file name = AST/MSLB/pal_mslb_noblegas_db.rft Dose conversion file name = AST/MSLB/nai-1101-001rev0.dcf

  • RADTRAD-NAI 1.1a(QA)
  • 26 May 2006 14:06:49
    • Noble Gas Activity Dose
  • Nuclide inventory file AST/MSLB/pal_mslb_db_ast.nif
  • Plant power 2703
  • Compartments 3
  • Compartment 1:

PCS 3

432977 0

0 0

0

  • Compartment 2:

Environment 2

2e+20 0

0 0

0

  • Compartment 3:

Control Room 1

35923 0

1 0

0

  • Pathways 5
  • Pathway 1:

SG Tube Leakage 1

2 2

Numerical Applications Inc. Attachment 4 Page 69 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1

  • Pathway 2:

Control Room Unfiltered Makeup 2

3 2

  • Pathway 3:

Control Room Filtered Makeup 2

3 2

  • Pathway 4:

Control Room Unfiltered Inleakage 2

3 2

  • Pathway 5:

Control Room Exhaust 3

2 2

  • Sources 3

1 1 2 0 3 0

  • dose conversion factors filename AST/MSLB/nai-1101-001rev0.dcf
  • release fraction and timing filename AST/MSLB/pal_mslb_noblegas_db.rft 0

1 1

  • Iodine 1 0 0
  • Overlying pool
  • aerosol model 0
  • elemental model 0
  • organic model 0
  • pH tracking 0
  • Compartment detail
  • Compartment 1:

1

  • spray model 0

0 0

  • filter model 0
  • deposition model 0

0

  • Compartment 2:

1

  • spray model 0

0 0

  • filter model 0
  • deposition model 0

0

  • Compartment 3:

1

  • spray model 0

0 0

  • filter model

Numerical Applications Inc. Attachment 4 Page 70 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 1

3 0 0 99 99 99 0.3333 1413.6 99 99 99 720 1413.6 99 99 99

  • deposition model 0

0

  • Pathways:
  • Pathway 1
  • filter efficiency model 1

3 0 5.005 0 0 0 12 0 0 0 0 720 0 0 0 0

  • Pathway 2
  • filter efficiency model 1

3 0 660 0 0 0 0.3333 0 0 0 0 720 0 0 0 0

  • Pathway 3
  • filter efficiency model 1

3 0 0 99 99 99 0.3333 1413.6 99 99 99 720 1413.6 99 99 99

  • Pathway 4
  • filter efficiency model 1

3 0 0 0 0 0 0.3333 10 0 0 0 720 10 0 0 0

  • Pathway 5
  • filter efficiency model 1

3 0 660 0 0 0 0.3333 1423.6 0 0 0 720 1423.6 0 0 0

  • x/q tables 4

EAB 2

0 0.000539 720 0.000539 LPZ 6

0 6.66e-05 2 3.03e-05 8 2.04e-05 24 8.67e-06 96 2.54e-06 720 2.54e-06 Control Room Unfiltered 6

0 0.0131 2 0.0113 8 0.00468 24 0.00287 96 0.00236 720 0.00236 Control Room Filtered 6

0 0.000799 2 0.000643 8 0.000258 24 0.000175 96 0.000132

Numerical Applications Inc. Attachment 4 Page 71 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 720 0.000132

  • dose locations 3
  • location name, compartment number and x/q table EAB 2

1

  • br model 1

4 0 0.00035 8 0.00018 24 0.00023 720 0.00023

  • of model 0
  • location x/q input to be included 0
  • location name, compartment number and x/q table LPZ 2

2

  • br model 1

4 0 0.00035 8 0.00018 24 0.00023 720 0.00023

  • of model 0
  • location x/q input to be included 0
  • location name, compartment number and x/q table Control Room 3

0

  • br model 1

2 0 0.00035 720 0.00035

  • of model 1

4 0 1 24 0.6 96 0.4 720 0.4

  • location x/q input to be included 1
  • number of intake combinations 3
  • intake combinations 2 1 3 3 1 4 4 1 3
  • time step count 1

0 0.02

  • show plant, scenario, event, step, model 1

1 1

0 1

RADTRAD-NAI Version 1.1a(QA) run on May 26, 2006 at 14:06:58 Plant Description

Numerical Applications Inc. Attachment 4 Page 72 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Number of Nuclides = 107 Inventory Power = 2.7030E+03 MWth Plant Power Level = 2.7030E+03 MWth Number of compartments = 3 Compartment information Compartment number 1 (Source term fraction = 1.0000E+00)

Name: PCS Compartment volume = 4.3298E+05 (Cubic feet)

Pathways into and out of compartment 1 Pathway to compartment number 2: SG Tube Leakage Compartment number 2 Name: Environment Pathways into and out of compartment 2 Pathway to compartment number 3: Control Room Unfiltered Makeup Pathway to compartment number 3: Control Room Filtered Makeup Pathway to compartment number 3: Control Room Unfiltered Inleakage Pathway from compartment number 1: SG Tube Leakage Pathway from compartment number 3: Control Room Exhaust Compartment number 3 Name: Control Room Compartment volume = 3.5923E+04 (Cubic feet)

Removal devices within compartment:

Filter(s)

Pathways into and out of compartment 3 Pathway to compartment number 2: Control Room Exhaust Pathway from compartment number 2: Control Room Unfiltered Makeup Pathway from compartment number 2: Control Room Filtered Makeup Pathway from compartment number 2: Control Room Unfiltered Inleakage Total number of pathways = 5 RADTRAD-NAI Version 1.1a(QA) run on May 26, 2006 at 14:06:58 Scenario Description Radioactive Decay is enabled Calculation of Daughters is enabled Iodine fractions Aerosol = 1.0000E+00 Elemental = 0.0000E+00 Organic = 0.0000E+00 COMPARTMENT DATA Compartment number 1: PCS Compartment number 2: Environment Compartment number 3: Control Room Compartment Filter Data Time (hr) Flow Rate Filter Efficiencies (%)

(cfm) Aerosol Elemental Organic 0.0000E+00 0.0000E+00 9.9000E+01 9.9000E+01 9.9000E+01 3.3330E-01 1.4136E+03 9.9000E+01 9.9000E+01 9.9000E+01 7.2000E+02 1.4136E+03 9.9000E+01 9.9000E+01 9.9000E+01 PATHWAY DATA

Numerical Applications Inc. Attachment 4 Page 73 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Pathway number 1: SG Tube Leakage Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)

(cfm) Aerosol Elemental Organic 0.0000E+00 5.0050E+00 0.0000E+00 0.0000E+00 0.0000E+00 1.2000E+01 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Pathway number 2: Control Room Unfiltered Makeup Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)

(cfm) Aerosol Elemental Organic 0.0000E+00 6.6000E+02 0.0000E+00 0.0000E+00 0.0000E+00 3.3330E-01 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Pathway number 3: Control Room Filtered Makeup Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)

(cfm) Aerosol Elemental Organic 0.0000E+00 0.0000E+00 9.9000E+01 9.9000E+01 9.9000E+01 3.3330E-01 1.4136E+03 9.9000E+01 9.9000E+01 9.9000E+01 7.2000E+02 1.4136E+03 9.9000E+01 9.9000E+01 9.9000E+01 Pathway number 4: Control Room Unfiltered Inleakage Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)

(cfm) Aerosol Elemental Organic 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 3.3330E-01 1.0000E+01 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 1.0000E+01 0.0000E+00 0.0000E+00 0.0000E+00 Pathway number 5: Control Room Exhaust Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)

(cfm) Aerosol Elemental Organic 0.0000E+00 6.6000E+02 0.0000E+00 0.0000E+00 0.0000E+00 3.3330E-01 1.4236E+03 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 1.4236E+03 0.0000E+00 0.0000E+00 0.0000E+00 X/Q DATA X/Q table 1: EAB Time (hr) X/Q (s

  • m^-3) 0.0000E+00 5.3900E-04 7.2000E+02 5.3900E-04 X/Q table 2: LPZ Time (hr) X/Q (s
  • m^-3) 0.0000E+00 6.6600E-05 2.0000E+00 3.0300E-05 8.0000E+00 2.0400E-05 2.4000E+01 8.6700E-06 9.6000E+01 2.5400E-06 7.2000E+02 2.5400E-06 X/Q table 3: Control Room Unfiltered Time (hr) X/Q (s
  • m^-3) 0.0000E+00 1.3100E-02 2.0000E+00 1.1300E-02 8.0000E+00 4.6800E-03 2.4000E+01 2.8700E-03

Numerical Applications Inc. Attachment 4 Page 74 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 9.6000E+01 2.3600E-03 7.2000E+02 2.3600E-03 X/Q table 4: Control Room Filtered Time (hr) X/Q (s

  • m^-3) 0.0000E+00 7.9900E-04 2.0000E+00 6.4300E-04 8.0000E+00 2.5800E-04 2.4000E+01 1.7500E-04 9.6000E+01 1.3200E-04 7.2000E+02 1.3200E-04 LOCATION DATA Location EAB is in compartment 2 Using X/Q Table 1 Location Breathing Rate Data Time (hr) Breathing Rate (m^3
  • sec^-1) 0.0000E+00 3.5000E-04 8.0000E+00 1.8000E-04 2.4000E+01 2.3000E-04 7.2000E+02 2.3000E-04 Location LPZ is in compartment 2 Using X/Q Table 2 Location Breathing Rate Data Time (hr) Breathing Rate (m^3
  • sec^-1) 0.0000E+00 3.5000E-04 8.0000E+00 1.8000E-04 2.4000E+01 2.3000E-04 7.2000E+02 2.3000E-04 Location Control Room is in compartment 3 Inleakage X/Q Table Assignments Inleakage Path Source Path X/Q Table 2 1 3 3 1 4 4 1 3 Location Breathing Rate Data Time (hr) Breathing Rate (m^3
  • sec^-1) 0.0000E+00 3.5000E-04 7.2000E+02 3.5000E-04 Location Occupancy Factor Data Time (hr) Occupancy Factor 0.0000E+00 1.0000E+00 2.4000E+01 6.0000E-01 9.6000E+01 4.0000E-01 7.2000E+02 4.0000E-01 USER SPECIFIED TIME STEP DATA - SUPPLEMENTAL TIME STEPS Time Time step 0.0000E+00 2.0000E-02 RADTRAD-NAI Version 1.1a(QA) run on May 26, 2006 at 14:06:58

Numerical Applications Inc. Attachment 4 Page 75 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Dose, Detailed Model and Detailed Inventory Output Detailed model information at time (H) = 0.0010 EAB Doses:

Time (h) = 0.0010 Whole Body Thyroid Skin TEDE Delta dose (rem) 1.0872E-05 4.9052E-11 2.0260E-05 1.0873E-05 Accumulated dose (rem) 1.0872E-05 4.9052E-11 2.0260E-05 1.0873E-05 LPZ Doses:

Time (h) = 0.0010 Whole Body Thyroid Skin TEDE Delta dose (rem) 1.3434E-06 6.0609E-12 2.5034E-06 1.3434E-06 Accumulated dose (rem) 1.3434E-06 6.0609E-12 2.5034E-06 1.3434E-06 Control Room Doses:

Time (h) = 0.0010 Whole Body Thyroid Skin TEDE Delta dose (rem) 3.2524E-09 6.5955E-13 2.0519E-07 3.2588E-09 Accumulated dose (rem) 3.2524E-09 6.5955E-13 2.0519E-07 3.2588E-09 PCS Compartment Atmosphere Nuclide Inventory:

Time (h) = 0.0010 Ci kg Atoms Bq Kr-85 2.1461E+03 5.4700E-03 3.8754E+22 7.9405E+13 Kr-85m 1.9867E+04 2.4141E-06 1.7103E+19 7.3506E+14 Kr-87 3.8290E+04 1.3518E-06 9.3571E+18 1.4167E+15 Kr-88 5.3904E+04 4.2988E-06 2.9418E+19 1.9944E+15 Xe-133 1.4953E+05 7.9886E-04 3.6172E+21 5.5327E+15 Xe-135 4.7859E+04 1.8741E-05 8.3601E+19 1.7708E+15 Kr-83m 9.2987E+03 4.5069E-07 3.2700E+18 3.4405E+14 Xe-138 1.2316E+05 1.2808E-06 5.5894E+18 4.5569E+15 Xe-131m 8.5129E+02 1.0163E-05 4.6721E+19 3.1498E+13 Xe-133m 4.7521E+03 1.0591E-05 4.7954E+19 1.7583E+14 Xe-135m 3.0521E+04 3.3506E-07 1.4946E+18 1.1293E+15 Cs-138 1.1992E+02 2.8339E-09 1.2367E+16 4.4369E+12 Rb-88 9.4816E+01 7.8988E-10 5.4054E+15 3.5082E+12 PCS Transport Group Inventory:

Overlying Time (h) = 0.0010 Atmosphere Sump Pool Noble gases (atoms) 4.2616E+22 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 3.6238E-09 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 0.0010 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 SG Tube Leakage Transport Group Inventory:

Pathway Time (h) = 0.0010 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Environment Integral Nuclide Release:

Time (h) = 0.0010 Ci kg Atoms Bq

Numerical Applications Inc. Attachment 4 Page 76 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Kr-85 5.1243E-04 1.3061E-09 9.2536E+15 1.8960E+07 Kr-85m 4.7436E-03 5.7642E-13 4.0838E+12 1.7551E+08 Kr-87 9.1428E-03 3.2277E-13 2.2342E+12 3.3828E+08 Kr-88 1.2871E-02 1.0265E-12 7.0244E+12 4.7622E+08 Xe-133 3.5704E-02 1.9075E-10 8.6369E+14 1.3211E+09 Xe-135 1.1427E-02 4.4748E-12 1.9961E+13 4.2281E+08 Kr-83m 2.2202E-03 1.0761E-13 7.8078E+11 8.2148E+07 Xe-138 2.9407E-02 3.0583E-13 1.3346E+12 1.0881E+09 Xe-131m 2.0327E-04 2.4267E-12 1.1156E+13 7.5209E+06 Xe-133m 1.1347E-03 2.5288E-12 1.1450E+13 4.1983E+07 Xe-135m 7.2865E-03 7.9990E-14 3.5682E+11 2.6960E+08 Cs-138 3.1988E-05 7.5595E-16 3.2989E+09 1.1835E+06 Rb-88 2.5289E-05 2.1068E-16 1.4417E+09 9.3571E+05 Environment Transport Group Inventory:

Present Release Integral Time (h) = 0.0010 Release Rate/s Release Noble gases (atoms) 1.0176E+16 5.0878E+15 1.0176E+16 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 9.6663E-16 4.8331E-16 9.6663E-16 SG Tube Leakage Transport Group Inventory:

Pathway Time (h) = 0.0010 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:

Pathway Time (h) = 0.0010 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Filtered Makeup Transport Group Inventory:

Pathway Time (h) = 0.0010 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Inleakage Transport Group Inventory:

Pathway Time (h) = 0.0010 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:

Pathway Time (h) = 0.0010 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Compartment Atmosphere Nuclide Inventory:

Time (h) = 0.0010 Ci kg Atoms Bq Kr-85 3.0357E-06 7.7375E-12 5.4819E+13 1.1232E+05 Kr-85m 2.8102E-05 3.4147E-15 2.4193E+10 1.0398E+06

Numerical Applications Inc. Attachment 4 Page 77 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Kr-87 5.4163E-05 1.9121E-15 1.3236E+10 2.0040E+06 Kr-88 7.6248E-05 6.0808E-15 4.1613E+10 2.8212E+06 Xe-133 2.1152E-04 1.1300E-12 5.1166E+12 7.8261E+06 Xe-135 6.7696E-05 2.6509E-14 1.1825E+11 2.5048E+06 Kr-83m 1.3153E-05 6.3748E-16 4.6253E+09 4.8665E+05 Xe-138 1.7421E-04 1.8118E-15 7.9064E+09 6.4459E+06 Xe-131m 1.2042E-06 1.4376E-14 6.6088E+10 4.4554E+04 Xe-133m 6.7220E-06 1.4981E-14 6.7832E+10 2.4871E+05 Xe-135m 4.3161E-05 4.7382E-16 2.1136E+09 1.5970E+06 Cs-138 2.0053E-07 4.7391E-18 2.0681E+07 7.4197E+03 Rb-88 1.5853E-07 1.3207E-18 9.0379E+06 5.8657E+03 Control Room Transport Group Inventory:

Overlying Time (h) = 0.0010 Atmosphere Sump Pool Noble gases (atoms) 6.0281E+13 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 6.0598E-18 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 0.0010 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:

Pathway Time (h) = 0.0010 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Filtered Makeup Transport Group Inventory:

Pathway Time (h) = 0.0010 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Inleakage Transport Group Inventory:

Pathway Time (h) = 0.0010 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:

Pathway Time (h) = 0.0010 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Detailed model information at time (H) = 0.3333 EAB Doses:

Time (h) = 0.3333 Whole Body Thyroid Skin TEDE Delta dose (rem) 7.0044E-03 1.2791E-05 1.3855E-02 7.1327E-03 Accumulated dose (rem) 7.0152E-03 1.2792E-05 1.3875E-02 7.1435E-03 LPZ Doses:

Numerical Applications Inc. Attachment 4 Page 78 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Time (h) = 0.3333 Whole Body Thyroid Skin TEDE Delta dose (rem) 8.6547E-04 1.5805E-06 1.7119E-03 8.8133E-04 Accumulated dose (rem) 8.6682E-04 1.5805E-06 1.7144E-03 8.8267E-04 Control Room Doses:

Time (h) = 0.3333 Whole Body Thyroid Skin TEDE Delta dose (rem) 8.1234E-04 6.4608E-05 5.5370E-02 1.4628E-03 Accumulated dose (rem) 8.1234E-04 6.4608E-05 5.5370E-02 1.4628E-03 PCS Compartment Atmosphere Nuclide Inventory:

Time (h) = 0.3333 Ci kg Atoms Bq Kr-85 2.1456E+03 5.4688E-03 3.8746E+22 7.9387E+13 Kr-85m 1.8867E+04 2.2925E-06 1.6242E+19 6.9806E+14 Kr-87 3.1939E+04 1.1276E-06 7.8051E+18 1.1818E+15 Kr-88 4.9693E+04 3.9630E-06 2.7120E+19 1.8387E+15 Xe-133 1.4923E+05 7.9726E-04 3.6099E+21 5.5216E+15 Xe-135 4.7153E+04 1.8464E-05 8.2367E+19 1.7447E+15 Kr-83m 8.1971E+03 3.9730E-07 2.8826E+18 3.0329E+14 Xe-138 4.6430E+04 4.8287E-07 2.1072E+18 1.7179E+15 Xe-131m 8.5041E+02 1.0153E-05 4.6673E+19 3.1465E+13 Xe-133m 4.7302E+03 1.0542E-05 4.7733E+19 1.7502E+14 Xe-135m 1.2358E+04 1.3567E-07 6.0520E+17 4.5726E+14 Cs-138 2.6931E+04 6.3646E-07 2.7774E+18 9.9646E+14 Rb-88 2.8490E+04 2.3734E-07 1.6242E+18 1.0541E+15 PCS Transport Group Inventory:

Overlying Time (h) = 0.3333 Atmosphere Sump Pool Noble gases (atoms) 4.2589E+22 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 8.7380E-07 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 0.3333 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 SG Tube Leakage Transport Group Inventory:

Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Environment Integral Nuclide Release:

Time (h) = 0.3333 Ci kg Atoms Bq Kr-85 4.9338E-01 1.2576E-06 8.9096E+18 1.8255E+10 Kr-85m 4.3384E+00 5.2718E-10 3.7350E+15 1.6052E+11 Kr-87 7.3445E+00 2.5929E-10 1.7948E+15 2.7175E+11 Kr-88 1.1427E+01 9.1131E-10 6.2364E+15 4.2280E+11 Xe-133 3.4316E+01 1.8333E-07 8.3011E+17 1.2697E+12 Xe-135 1.0843E+01 4.2459E-09 1.8940E+16 4.0119E+11 Kr-83m 1.8849E+00 9.1360E-11 6.6287E+14 6.9743E+10 Xe-138 1.0677E+01 1.1104E-10 4.8455E+14 3.9504E+11 Xe-131m 1.9555E-01 2.3346E-09 1.0733E+16 7.2355E+09 Xe-133m 1.0877E+00 2.4241E-09 1.0976E+16 4.0246E+10 Xe-135m 2.8418E+00 3.1197E-11 1.3917E+14 1.0515E+11 Cs-138 6.1929E+00 1.4635E-10 6.3867E+14 2.2914E+11 Rb-88 6.5513E+00 5.4577E-11 3.7349E+14 2.4240E+11 Environment Transport Group Inventory:

Present Release Integral

Numerical Applications Inc. Attachment 4 Page 79 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Time (h) = 0.3333 Release Rate/s Release Noble gases (atoms) 3.9174E+17 5.4409E+15 9.7934E+18 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 8.0374E-12 1.1163E-13 2.0093E-10 SG Tube Leakage Transport Group Inventory:

Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:

Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Filtered Makeup Transport Group Inventory:

Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Inleakage Transport Group Inventory:

Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:

Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Compartment Atmosphere Nuclide Inventory:

Time (h) = 0.3333 Ci kg Atoms Bq Kr-85 1.6918E-03 4.3121E-09 3.0551E+16 6.2596E+07 Kr-85m 1.4876E-02 1.8077E-12 1.2807E+13 5.5042E+08 Kr-87 2.5184E-02 8.8909E-13 6.1543E+12 9.3181E+08 Kr-88 3.9183E-02 3.1248E-12 2.1384E+13 1.4498E+09 Xe-133 1.1767E-01 6.2863E-10 2.8464E+15 4.3537E+09 Xe-135 3.7180E-02 1.4559E-11 6.4946E+13 1.3757E+09 Kr-83m 6.4634E-03 3.1327E-13 2.2729E+12 2.3914E+08 Xe-138 3.6610E-02 3.8074E-13 1.6615E+12 1.3546E+09 Xe-131m 6.7054E-04 8.0054E-12 3.6801E+13 2.4810E+07 Xe-133m 3.7298E-03 8.3123E-12 3.7637E+13 1.3800E+08 Xe-135m 9.7445E-03 1.0697E-13 4.7719E+11 3.6055E+08 Cs-138 2.1235E-02 5.0184E-13 2.1900E+12 7.8570E+08 Rb-88 2.2464E-02 1.8714E-13 1.2807E+12 8.3118E+08 Control Room Transport Group Inventory:

Overlying Time (h) = 0.3333 Atmosphere Sump Pool Noble gases (atoms) 3.3581E+16 0.0000E+00 0.0000E+00

Numerical Applications Inc. Attachment 4 Page 80 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 6.8898E-13 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 0.3333 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:

Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Filtered Makeup Transport Group Inventory:

Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Inleakage Transport Group Inventory:

Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:

Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Detailed model information at time (H) = 2.0000 EAB Doses:

Time (h) = 2.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 2.3424E-02 9.7905E-05 5.4018E-02 2.4560E-02 Accumulated dose (rem) 3.0439E-02 1.1070E-04 6.7893E-02 3.1703E-02 LPZ Doses:

Time (h) = 2.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 2.8943E-03 1.2097E-05 6.6746E-03 3.0347E-03 Accumulated dose (rem) 3.7611E-03 1.3678E-05 8.3890E-03 3.9173E-03 Control Room Doses:

Time (h) = 2.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 1.9251E-03 1.6067E-04 1.3792E-01 3.7751E-03 Accumulated dose (rem) 2.7374E-03 2.2528E-04 1.9329E-01 5.2380E-03 PCS Compartment Atmosphere Nuclide Inventory:

Time (h) = 2.0000 Ci kg Atoms Bq Kr-85 2.1431E+03 5.4625E-03 3.8701E+22 7.9296E+13 Kr-85m 1.4561E+04 1.7694E-06 1.2536E+19 5.3877E+14 Kr-87 1.2861E+04 4.5405E-07 3.1429E+18 4.7586E+14

Numerical Applications Inc. Attachment 4 Page 81 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Kr-88 3.3047E+04 2.6355E-06 1.8036E+19 1.2227E+15 Xe-133 1.4774E+05 7.8929E-04 3.5738E+21 5.4664E+15 Xe-135 4.1787E+04 1.6363E-05 7.2994E+19 1.5461E+15 Kr-83m 4.3550E+03 2.1108E-07 1.5315E+18 1.6114E+14 Xe-138 3.4821E+02 3.6213E-09 1.5803E+16 1.2884E+13 Xe-131m 8.4600E+02 1.0100E-05 4.6431E+19 3.1302E+13 Xe-133m 4.6220E+03 1.0301E-05 4.6641E+19 1.7101E+14 Xe-135m 1.3262E+02 1.4559E-09 6.4946E+15 4.9070E+12 Cs-138 7.1372E+03 1.6867E-07 7.3605E+17 2.6408E+14 Rb-88 3.7195E+04 3.0986E-07 2.1205E+18 1.3762E+15 PCS Transport Group Inventory:

Overlying Time (h) = 2.0000 Atmosphere Sump Pool Noble gases (atoms) 4.2476E+22 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 4.7853E-07 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 2.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 SG Tube Leakage Transport Group Inventory:

Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Environment Integral Nuclide Release:

Time (h) = 2.0000 Ci kg Atoms Bq Kr-85 2.9735E+00 7.5790E-06 5.3696E+19 1.1002E+11 Kr-85m 2.0203E+01 2.4550E-09 1.7393E+16 7.4752E+11 Kr-87 1.7844E+01 6.2998E-10 4.3607E+15 6.6025E+11 Kr-88 4.5852E+01 3.6566E-09 2.5024E+16 1.6965E+12 Xe-133 2.0499E+02 1.0951E-06 4.9586E+18 7.5844E+12 Xe-135 5.7979E+01 2.2704E-08 1.0128E+17 2.1452E+12 Kr-83m 6.0424E+00 2.9287E-10 2.1249E+15 2.2357E+11 Xe-138 4.8313E-01 5.0244E-12 2.1926E+13 1.7876E+10 Xe-131m 1.1738E+00 1.4014E-08 6.4421E+16 4.3430E+10 Xe-133m 6.4128E+00 1.4292E-08 6.4712E+16 2.3727E+11 Xe-135m 1.8401E-01 2.0200E-12 9.0110E+12 6.8083E+09 Cs-138 9.8979E+00 2.3391E-10 1.0208E+15 3.6622E+11 Rb-88 5.1602E+01 4.2988E-10 2.9418E+15 1.9093E+12 Environment Transport Group Inventory:

Present Release Integral Time (h) = 2.0000 Release Rate/s Release Noble gases (atoms) 5.8923E+17 8.1838E+15 5.8934E+19 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 6.6352E-12 9.2156E-14 6.6380E-10 SG Tube Leakage Transport Group Inventory:

Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:

Numerical Applications Inc. Attachment 4 Page 82 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Filter Pathway Nuclide Inventory for Control Room Filtered Makeup Time (h) = 2.0000 Ci kg Atoms Bq Cs-138 3.6166E-03 8.5470E-14 3.7298E+11 1.3381E+08 Rb-88 5.9224E-03 4.9337E-14 3.3763E+11 2.1913E+08 Control Room Filtered Makeup Transport Group Inventory:

Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 1.3481E-13 Control Room Unfiltered Inleakage Transport Group Inventory:

Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:

Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Compartment Atmosphere Nuclide Inventory:

Time (h) = 2.0000 Ci kg Atoms Bq Kr-85 3.9706E-04 1.0120E-09 7.1702E+15 1.4691E+07 Kr-85m 2.6978E-03 3.2782E-13 2.3225E+12 9.9818E+07 Kr-87 2.3828E-03 8.4122E-14 5.8229E+11 8.8164E+07 Kr-88 6.1227E-03 4.8828E-13 3.3415E+12 2.2654E+08 Xe-133 2.7372E-02 1.4623E-10 6.6213E+14 1.0128E+09 Xe-135 7.7420E-03 3.0317E-12 1.3524E+13 2.8645E+08 Kr-83m 8.0686E-04 3.9107E-14 2.8375E+11 2.9854E+07 Xe-138 6.4513E-05 6.7093E-16 2.9278E+09 2.3870E+06 Xe-131m 1.5674E-04 1.8713E-12 8.6023E+12 5.7993E+06 Xe-133m 8.5632E-04 1.9084E-12 8.6412E+12 3.1684E+07 Xe-135m 2.4571E-05 2.6974E-16 1.2033E+09 9.0913E+05 Cs-138 1.0215E-04 2.4140E-15 1.0534E+10 3.7794E+06 Rb-88 2.5720E-03 2.1427E-14 1.4663E+11 9.5165E+07 Control Room Transport Group Inventory:

Overlying Time (h) = 2.0000 Atmosphere Sump Pool Noble gases (atoms) 7.8696E+15 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 2.3841E-14 0.0000E+00 0.0000E+00 Recirculating Filter Inventory Time (h) = 2.0000 Ci kg Atoms Bq Cs-138 2.2692E-03 5.3628E-14 2.3403E+11 8.3962E+07 Rb-88 3.4345E-03 2.8611E-14 1.9580E+11 1.2707E+08 Deposition Recirculating

Numerical Applications Inc. Attachment 4 Page 83 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Time (h) = 2.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 8.2240E-14 Control Room Unfiltered Makeup Transport Group Inventory:

Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Filter Pathway Nuclide Inventory for Control Room Filtered Makeup Time (h) = 2.0000 Ci kg Atoms Bq Cs-138 3.6166E-03 8.5470E-14 3.7298E+11 1.3381E+08 Rb-88 5.9224E-03 4.9337E-14 3.3763E+11 2.1913E+08 Control Room Filtered Makeup Transport Group Inventory:

Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 1.3481E-13 Control Room Unfiltered Inleakage Transport Group Inventory:

Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:

Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Total Filter Nuclide Inventory:

Time (h) = 2.0000 Ci kg Atoms Bq Cs-138 5.8858E-03 1.3910E-13 6.0700E+11 2.1778E+08 Rb-88 9.3568E-03 7.7948E-14 5.3343E+11 3.4620E+08 Detailed model information at time (H) = 8.0000 EAB Doses:

Time (h) = 8.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 2.8317E-02 8.8653E-05 7.2650E-02 2.9692E-02 Accumulated dose (rem) 5.8755E-02 1.9935E-04 1.4054E-01 6.1395E-02 LPZ Doses:

Time (h) = 8.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 1.5918E-03 4.9837E-06 4.0840E-03 1.6691E-03 Accumulated dose (rem) 5.3529E-03 1.8662E-05 1.2473E-02 5.5865E-03 Control Room Doses:

Time (h) = 8.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 9.7330E-04 3.9463E-05 7.1241E-02 1.6157E-03 Accumulated dose (rem) 3.7107E-03 2.6474E-04 2.6453E-01 6.8537E-03

Numerical Applications Inc. Attachment 4 Page 84 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 PCS Compartment Atmosphere Nuclide Inventory:

Time (h) = 8.0000 Ci kg Atoms Bq Kr-85 2.1342E+03 5.4398E-03 3.8540E+22 7.8966E+13 Kr-85m 5.7309E+03 6.9639E-07 4.9338E+18 2.1204E+14 Kr-87 4.8657E+02 1.7178E-08 1.1891E+17 1.8003E+13 Kr-88 7.6093E+03 6.0684E-07 4.1528E+18 2.8154E+14 Xe-133 1.4249E+05 7.6124E-04 3.4468E+21 5.2721E+15 Xe-135 2.6338E+04 1.0313E-05 4.6007E+19 9.7450E+14 Kr-83m 4.4689E+02 2.1660E-08 1.5716E+17 1.6535E+13 Xe-138 7.8006E-06 8.1125E-17 3.5402E+08 2.8862E+05 Xe-131m 8.3030E+02 9.9128E-06 4.5569E+19 3.0721E+13 Xe-133m 4.2523E+03 9.4768E-06 4.2910E+19 1.5734E+14 Xe-135m 1.0792E-05 1.1848E-16 5.2851E+08 3.9932E+05 Cs-138 3.1821E+00 7.5202E-11 3.2817E+14 1.1774E+11 Rb-88 8.6971E+03 7.2453E-08 4.9582E+17 3.2179E+14 PCS Transport Group Inventory:

Overlying Time (h) = 8.0000 Atmosphere Sump Pool Noble gases (atoms) 4.2131E+22 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 7.2528E-08 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 8.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 SG Tube Leakage Transport Group Inventory:

Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Environment Integral Nuclide Release:

Time (h) = 8.0000 Ci kg Atoms Bq Kr-85 1.1873E+01 3.0264E-05 2.1441E+20 4.3932E+11 Kr-85m 3.1883E+01 3.8743E-09 2.7449E+16 1.1797E+12 Kr-87 2.7070E+00 9.5567E-11 6.6152E+14 1.0016E+11 Kr-88 4.2334E+01 3.3761E-09 2.3104E+16 1.5663E+12 Xe-133 7.9272E+02 4.2351E-06 1.9176E+19 2.9331E+13 Xe-135 1.4653E+02 5.7378E-08 2.5595E+17 5.4215E+12 Kr-83m 2.4862E+00 1.2050E-10 8.7432E+14 9.1990E+10 Xe-131m 4.6193E+00 5.5149E-08 2.5352E+17 1.7091E+11 Xe-133m 2.3657E+01 5.2723E-08 2.3873E+17 8.7532E+11 Cs-138 1.7695E-02 4.1819E-13 1.8249E+12 6.5472E+08 Rb-88 4.8385E+01 4.0308E-10 2.7584E+15 1.7902E+12 Environment Transport Group Inventory:

Present Release Integral Time (h) = 8.0000 Release Rate/s Release Noble gases (atoms) 5.8442E+17 8.1169E+15 2.3439E+20 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 1.0058E-12 1.3969E-14 4.0349E-10 SG Tube Leakage Transport Group Inventory:

Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00

Numerical Applications Inc. Attachment 4 Page 85 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:

Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Filter Pathway Nuclide Inventory for Control Room Filtered Makeup Time (h) = 8.0000 Ci kg Atoms Bq Cs-138 7.1723E-06 1.6950E-16 7.3968E+08 2.6538E+05 Rb-88 1.1993E-03 9.9907E-15 6.8370E+10 4.4373E+07 Control Room Filtered Makeup Transport Group Inventory:

Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 1.0160E-14 Control Room Unfiltered Inleakage Transport Group Inventory:

Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:

Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Compartment Atmosphere Nuclide Inventory:

Time (h) = 8.0000 Ci kg Atoms Bq Kr-85 3.0034E-04 7.6552E-10 5.4236E+15 1.1113E+07 Kr-85m 8.0649E-04 9.7999E-14 6.9431E+11 2.9840E+07 Kr-87 6.8473E-05 2.4174E-15 1.6733E+10 2.5335E+06 Kr-88 1.0708E-03 8.5398E-14 5.8441E+11 3.9620E+07 Xe-133 2.0052E-02 1.0713E-10 4.8505E+14 7.4192E+08 Xe-135 3.7064E-03 1.4514E-12 6.4743E+12 1.3714E+08 Kr-83m 6.2889E-05 3.0481E-15 2.2116E+10 2.3269E+06 Xe-131m 1.1684E-04 1.3950E-12 6.4128E+12 4.3233E+06 Xe-133m 5.9841E-04 1.3336E-12 6.0386E+12 2.2141E+07 Cs-138 2.6974E-08 6.3747E-19 2.7819E+06 9.9805E+02 Rb-88 4.4409E-04 3.6996E-15 2.5317E+10 1.6431E+07 Control Room Transport Group Inventory:

Overlying Time (h) = 8.0000 Atmosphere Sump Pool Noble gases (atoms) 5.9289E+15 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 3.7002E-15 0.0000E+00 0.0000E+00 Recirculating Filter Inventory Time (h) = 8.0000 Ci kg Atoms Bq Cs-138 1.3734E-06 3.2457E-17 1.4164E+08 5.0816E+04

Numerical Applications Inc. Attachment 4 Page 86 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Rb-88 4.6773E-04 3.8965E-15 2.6665E+10 1.7306E+07 Deposition Recirculating Time (h) = 8.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 3.9289E-15 Control Room Unfiltered Makeup Transport Group Inventory:

Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Filter Pathway Nuclide Inventory for Control Room Filtered Makeup Time (h) = 8.0000 Ci kg Atoms Bq Cs-138 7.1723E-06 1.6950E-16 7.3968E+08 2.6538E+05 Rb-88 1.1993E-03 9.9907E-15 6.8370E+10 4.4373E+07 Control Room Filtered Makeup Transport Group Inventory:

Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 1.0160E-14 Control Room Unfiltered Inleakage Transport Group Inventory:

Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:

Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Total Filter Nuclide Inventory:

Time (h) = 8.0000 Ci kg Atoms Bq Cs-138 8.5457E-06 2.0196E-16 8.8132E+08 3.1619E+05 Rb-88 1.6670E-03 1.3887E-14 9.5035E+10 6.1679E+07 Detailed model information at time (H) = 12.0000 EAB Doses:

Time (h) = 12.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 6.7449E-03 7.5869E-06 1.8147E-02 6.8700E-03 Accumulated dose (rem) 6.5500E-02 2.0694E-04 1.5869E-01 6.8265E-02 LPZ Doses:

Time (h) = 12.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 2.5528E-04 2.8715E-07 6.8682E-04 2.6001E-04 Accumulated dose (rem) 5.6082E-03 1.8949E-05 1.3160E-02 5.8465E-03 Control Room Doses:

Numerical Applications Inc. Attachment 4 Page 87 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Time (h) = 12.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 1.1549E-04 3.5208E-06 9.3034E-03 1.7356E-04 Accumulated dose (rem) 3.8262E-03 2.6826E-04 2.7384E-01 7.0272E-03 PCS Compartment Atmosphere Nuclide Inventory:

Time (h) = 12.0000 Ci kg Atoms Bq Kr-85 2.1283E+03 5.4246E-03 3.8433E+22 7.8746E+13 Kr-85m 3.0778E+03 3.7400E-07 2.6497E+18 1.1388E+14 Kr-87 5.4835E+01 1.9359E-09 1.3400E+16 2.0289E+12 Kr-88 2.8586E+03 2.2797E-07 1.5601E+18 1.0577E+14 Xe-133 1.3909E+05 7.4307E-04 3.3646E+21 5.1463E+15 Xe-135 1.9360E+04 7.5811E-06 3.3818E+19 7.1632E+14 Kr-83m 9.7950E+01 4.7475E-09 3.4446E+16 3.6242E+12 Xe-131m 8.2000E+02 9.7898E-06 4.5004E+19 3.0340E+13 Xe-133m 4.0224E+03 8.9645E-06 4.0591E+19 1.4883E+14 Cs-138 1.8106E-02 4.2788E-13 1.8672E+12 6.6990E+08 Rb-88 3.2673E+03 2.7219E-08 1.8627E+17 1.2089E+14 PCS Transport Group Inventory:

Overlying Time (h) = 12.0000 Atmosphere Sump Pool Noble gases (atoms) 4.1921E+22 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 2.7219E-08 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 12.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 SG Tube Leakage Transport Group Inventory:

Pathway Time (h) = 12.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Environment Integral Nuclide Release:

Time (h) = 12.0000 Ci kg Atoms Bq Kr-85 1.7786E+01 4.5334E-05 3.2119E+20 6.5809E+11 Kr-85m 2.5722E+01 3.1255E-09 2.2144E+16 9.5170E+11 Kr-87 4.5826E-01 1.6178E-11 1.1199E+14 1.6956E+10 Kr-88 2.3890E+01 1.9052E-09 1.3038E+16 8.8391E+11 Xe-133 1.1624E+03 6.2099E-06 2.8118E+19 4.3008E+13 Xe-135 1.6179E+02 6.3356E-08 2.8262E+17 5.9864E+12 Kr-83m 8.1858E-01 3.9675E-11 2.8787E+14 3.0287E+10 Xe-131m 6.8528E+00 8.1814E-08 3.7610E+17 2.5355E+11 Xe-133m 3.3616E+01 7.4917E-08 3.3922E+17 1.2438E+12 Cs-138 1.5125E-04 3.5745E-15 1.5599E+10 5.5963E+06 Rb-88 2.7305E+01 2.2747E-10 1.5566E+15 1.0103E+12 Environment Transport Group Inventory:

Present Release Integral Time (h) = 12.0000 Release Rate/s Release Noble gases (atoms) 5.8151E+17 8.0765E+15 3.5034E+20 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 3.7752E-13 5.2434E-15 2.2747E-10 SG Tube Leakage Transport Group Inventory:

Pathway Time (h) = 12.0000 Filter Noble gases (atoms) 0.0000E+00

Numerical Applications Inc. Attachment 4 Page 88 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:

Pathway Time (h) = 12.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Filter Pathway Nuclide Inventory for Control Room Filtered Makeup Time (h) = 12.0000 Ci kg Atoms Bq Cs-138 4.9493E-08 1.1697E-18 5.1042E+06 1.8313E+03 Rb-88 1.8084E-04 1.5065E-15 1.0309E+10 6.6909E+06 Control Room Filtered Makeup Transport Group Inventory:

Pathway Time (h) = 12.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 1.5077E-15 Control Room Unfiltered Inleakage Transport Group Inventory:

Pathway Time (h) = 12.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:

Pathway Time (h) = 12.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Compartment Atmosphere Nuclide Inventory:

Time (h) = 12.0000 Ci kg Atoms Bq Kr-85 1.2061E-04 3.0743E-10 2.1781E+15 4.4627E+06 Kr-85m 1.7443E-04 2.1195E-14 1.5017E+11 6.4538E+06 Kr-87 3.1077E-06 1.0971E-16 7.5942E+08 1.1498E+05 Kr-88 1.6200E-04 1.2920E-14 8.8414E+10 5.9942E+06 Xe-133 7.8825E-03 4.2112E-11 1.9068E+14 2.9165E+08 Xe-135 1.0972E-03 4.2964E-13 1.9166E+12 4.0596E+07 Kr-83m 5.5511E-06 2.6905E-16 1.9521E+09 2.0539E+05 Xe-131m 4.6472E-05 5.5481E-13 2.5505E+12 1.7194E+06 Xe-133m 2.2796E-04 5.0804E-13 2.3004E+12 8.4345E+06 Rb-88 6.7386E-05 5.6137E-16 3.8417E+09 2.4933E+06 Control Room Transport Group Inventory:

Overlying Time (h) = 12.0000 Atmosphere Sump Pool Noble gases (atoms) 2.3758E+15 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 5.6137E-16 0.0000E+00 0.0000E+00 Recirculating Filter Inventory Time (h) = 12.0000 Ci kg Atoms Bq Cs-138 8.4745E-09 2.0028E-19 8.7397E+05 3.1356E+02

Numerical Applications Inc. Attachment 4 Page 89 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Rb-88 7.1159E-05 5.9281E-16 4.0568E+09 2.6329E+06 Deposition Recirculating Time (h) = 12.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 5.9301E-16 Control Room Unfiltered Makeup Transport Group Inventory:

Pathway Time (h) = 12.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Filter Pathway Nuclide Inventory for Control Room Filtered Makeup Time (h) = 12.0000 Ci kg Atoms Bq Cs-138 4.9493E-08 1.1697E-18 5.1042E+06 1.8313E+03 Rb-88 1.8084E-04 1.5065E-15 1.0309E+10 6.6909E+06 Control Room Filtered Makeup Transport Group Inventory:

Pathway Time (h) = 12.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 1.5077E-15 Control Room Unfiltered Inleakage Transport Group Inventory:

Pathway Time (h) = 12.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:

Pathway Time (h) = 12.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Total Filter Nuclide Inventory:

Time (h) = 12.0000 Ci kg Atoms Bq Cs-138 5.7968E-08 1.3699E-18 5.9782E+06 2.1448E+03 Rb-88 2.5200E-04 2.0993E-15 1.4366E+10 9.3238E+06 Detailed model information at time (H) = 24.0000 EAB Doses:

Time (h) = 24.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 8.7834E-08 3.5351E-11 2.2639E-07 8.8417E-08 Accumulated dose (rem) 6.5500E-02 2.0694E-04 1.5869E-01 6.8265E-02 LPZ Doses:

Time (h) = 24.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 3.3243E-09 1.3380E-12 8.5683E-09 3.3464E-09 Accumulated dose (rem) 5.6082E-03 1.8949E-05 1.3160E-02 5.8465E-03 Control Room Doses:

Numerical Applications Inc. Attachment 4 Page 90 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Time (h) = 24.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 7.1661E-06 1.8995E-07 6.2530E-04 1.0300E-05 Accumulated dose (rem) 3.8334E-03 2.6845E-04 2.7446E-01 7.0375E-03 PCS Compartment Atmosphere Nuclide Inventory:

Time (h) = 24.0000 Ci kg Atoms Bq Kr-85 2.1281E+03 5.4242E-03 3.8430E+22 7.8740E+13 Kr-85m 4.8074E+02 5.8417E-08 4.1388E+17 1.7788E+13 Kr-87 7.9143E-02 2.7940E-12 1.9340E+13 2.9283E+09 Kr-88 1.5283E+02 1.2188E-08 8.3405E+16 5.6546E+12 Xe-133 1.3043E+05 6.9683E-04 3.1552E+21 4.8260E+15 Xe-135 7.7537E+03 3.0362E-06 1.3544E+19 2.8689E+14 Kr-83m 1.0400E+00 5.0408E-11 3.6574E+14 3.8481E+10 Xe-131m 7.9647E+02 9.5088E-06 4.3712E+19 2.9469E+13 Xe-133m 3.4332E+03 7.6513E-06 3.4645E+19 1.2703E+14 Cs-138 3.3628E-09 7.9473E-20 3.4681E+05 1.2442E+02 Rb-88 1.7467E+02 1.4552E-09 9.9581E+15 6.4629E+12 PCS Transport Group Inventory:

Overlying Time (h) = 24.0000 Atmosphere Sump Pool Noble gases (atoms) 4.1677E+22 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 1.4552E-09 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 24.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 SG Tube Leakage Transport Group Inventory:

Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Environment Transport Group Inventory:

Present Release Integral Time (h) = 24.0000 Release Rate/s Release Noble gases (atoms) 4.6677E+01 6.4829E-01 3.4830E+20 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 8.0503E-31 1.1181E-32 1.2161E-11 SG Tube Leakage Transport Group Inventory:

Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:

Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Filtered Makeup Transport Group Inventory:

Numerical Applications Inc. Attachment 4 Page 91 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 2.1825E-25 Control Room Unfiltered Inleakage Transport Group Inventory:

Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:

Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Transport Group Inventory:

Overlying Time (h) = 24.0000 Atmosphere Sump Pool Noble gases (atoms) 9.5837E+02 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 1.6175E-29 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 24.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 4.1439E-26 Control Room Unfiltered Makeup Transport Group Inventory:

Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Filtered Makeup Transport Group Inventory:

Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 2.1825E-25 Control Room Unfiltered Inleakage Transport Group Inventory:

Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:

Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00

Numerical Applications Inc. Attachment 4 Page 92 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Detailed model information at time (H) = 96.0000 EAB Doses:

Time (h) = 96.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 1.4575E-20 1.0839E-24 4.5467E-20 1.4593E-20 Accumulated dose (rem) 6.5500E-02 2.0694E-04 1.5869E-01 6.8265E-02 LPZ Doses:

Time (h) = 96.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 2.3444E-22 1.7435E-26 7.3136E-22 2.3473E-22 Accumulated dose (rem) 5.6082E-03 1.8949E-05 1.3160E-02 5.8465E-03 Control Room Doses:

Time (h) = 96.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 7.1345E-19 2.7348E-21 7.5347E-17 7.5856E-19 Accumulated dose (rem) 3.8334E-03 2.6845E-04 2.7446E-01 7.0375E-03 PCS Compartment Atmosphere Nuclide Inventory:

Time (h) = 96.0000 Ci kg Atoms Bq Kr-85 2.1270E+03 5.4214E-03 3.8410E+22 7.8698E+13 Kr-85m 6.9812E-03 8.4831E-13 6.0102E+12 2.5831E+08 Kr-88 3.5682E-06 2.8456E-16 1.9474E+09 1.3202E+05 Xe-133 8.8445E+04 4.7251E-04 2.1395E+21 3.2725E+15 Xe-135 3.1997E+01 1.2530E-08 5.5893E+16 1.1839E+12 Xe-131m 6.6877E+02 7.9843E-06 3.6704E+19 2.4745E+13 Xe-133m 1.3272E+03 2.9579E-06 1.3393E+19 4.9108E+13 Rb-88 4.0783E-06 3.3975E-17 2.3250E+08 1.5090E+05 PCS Transport Group Inventory:

Overlying Time (h) = 96.0000 Atmosphere Sump Pool Noble gases (atoms) 4.0599E+22 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 3.3975E-17 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 96.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 SG Tube Leakage Transport Group Inventory:

Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Environment Transport Group Inventory:

Present Release Integral Time (h) = 96.0000 Release Rate/s Release Noble gases (atoms) 0.0000E+00 0.0000E+00 3.3929E+20 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 2.8393E-19 SG Tube Leakage Transport Group Inventory:

Pathway

Numerical Applications Inc. Attachment 4 Page 93 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:

Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Filtered Makeup Transport Group Inventory:

Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Inleakage Transport Group Inventory:

Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:

Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Transport Group Inventory:

Overlying Time (h) = 96.0000 Atmosphere Sump Pool Noble gases (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 96.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:

Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Filtered Makeup Transport Group Inventory:

Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00

Numerical Applications Inc. Attachment 4 Page 94 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Inleakage Transport Group Inventory:

Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:

Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Detailed model information at time (H) = 720.0000 EAB Doses:

Time (h) = 720.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 2.8724E-95 1.1293-106 9.9169E-95 2.8724E-95 Accumulated dose (rem) 6.5500E-02 2.0694E-04 1.5869E-01 6.8265E-02 LPZ Doses:

Time (h) = 720.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 1.3536E-97 5.3218-109 4.6733E-97 1.3536E-97 Accumulated dose (rem) 5.6082E-03 1.8949E-05 1.3160E-02 5.8465E-03 Control Room Doses:

Time (h) = 720.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 9.3737E-94 1.8996-103 1.0956E-91 9.3737E-94 Accumulated dose (rem) 3.8334E-03 2.6845E-04 2.7446E-01 7.0375E-03 PCS Compartment Atmosphere Nuclide Inventory:

Time (h) = 720.0000 Ci kg Atoms Bq Kr-85 2.1172E+03 5.3965E-03 3.8233E+22 7.8337E+13 Xe-133 2.8777E+03 1.5374E-05 6.9611E+19 1.0647E+14 Xe-131m 1.4708E+02 1.7560E-06 8.0724E+18 5.4421E+12 Xe-133m 3.5141E-01 7.8316E-10 3.5461E+15 1.3002E+10 PCS Transport Group Inventory:

Overlying Time (h) = 720.0000 Atmosphere Sump Pool Noble gases (atoms) 3.8311E+22 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 720.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 SG Tube Leakage Transport Group Inventory:

Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00

Numerical Applications Inc. Attachment 4 Page 95 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Environment Transport Group Inventory:

Present Release Integral Time (h) = 720.0000 Release Rate/s Release Noble gases (atoms) 0.0000E+00 0.0000E+00 3.2017E+20 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 SG Tube Leakage Transport Group Inventory:

Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:

Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Filtered Makeup Transport Group Inventory:

Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Inleakage Transport Group Inventory:

Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:

Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Transport Group Inventory:

Overlying Time (h) = 720.0000 Atmosphere Sump Pool Noble gases (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 720.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:

Numerical Applications Inc. Attachment 4 Page 96 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Filtered Makeup Transport Group Inventory:

Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Inleakage Transport Group Inventory:

Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:

Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Transport Group Totals in Model:

Noble Gases (atoms) 3.8631E+22 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 36004 I-131 Summary PCS Environment Control Room Time (hr) I-131 (Curies) I-131 (Curies) I-131 (Curies) 0.001 0.0000E+00 0.0000E+00 0.0000E+00 0.001 0.0000E+00 0.0000E+00 0.0000E+00 0.280 0.0000E+00 0.0000E+00 0.0000E+00 0.333 0.0000E+00 0.0000E+00 0.0000E+00 0.600 0.0000E+00 0.0000E+00 0.0000E+00 0.860 0.0000E+00 0.0000E+00 0.0000E+00 1.120 0.0000E+00 0.0000E+00 0.0000E+00 1.380 0.0000E+00 0.0000E+00 0.0000E+00 1.640 0.0000E+00 0.0000E+00 0.0000E+00 1.900 0.0000E+00 0.0000E+00 0.0000E+00 2.000 0.0000E+00 0.0000E+00 0.0000E+00 2.260 0.0000E+00 0.0000E+00 0.0000E+00 2.520 0.0000E+00 0.0000E+00 0.0000E+00 2.780 0.0000E+00 0.0000E+00 0.0000E+00 3.040 0.0000E+00 0.0000E+00 0.0000E+00 3.300 0.0000E+00 0.0000E+00 0.0000E+00 3.560 0.0000E+00 0.0000E+00 0.0000E+00 3.820 0.0000E+00 0.0000E+00 0.0000E+00 4.080 0.0000E+00 0.0000E+00 0.0000E+00 4.340 0.0000E+00 0.0000E+00 0.0000E+00 4.600 0.0000E+00 0.0000E+00 0.0000E+00 4.860 0.0000E+00 0.0000E+00 0.0000E+00

Numerical Applications Inc. Attachment 4 Page 97 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 5.120 0.0000E+00 0.0000E+00 0.0000E+00 5.380 0.0000E+00 0.0000E+00 0.0000E+00 5.640 0.0000E+00 0.0000E+00 0.0000E+00 5.900 0.0000E+00 0.0000E+00 0.0000E+00 6.160 0.0000E+00 0.0000E+00 0.0000E+00 6.420 0.0000E+00 0.0000E+00 0.0000E+00 6.680 0.0000E+00 0.0000E+00 0.0000E+00 6.940 0.0000E+00 0.0000E+00 0.0000E+00 7.200 0.0000E+00 0.0000E+00 0.0000E+00 7.460 0.0000E+00 0.0000E+00 0.0000E+00 7.720 0.0000E+00 0.0000E+00 0.0000E+00 7.980 0.0000E+00 0.0000E+00 0.0000E+00 8.000 0.0000E+00 0.0000E+00 0.0000E+00 8.260 0.0000E+00 0.0000E+00 0.0000E+00 8.520 0.0000E+00 0.0000E+00 0.0000E+00 8.780 0.0000E+00 0.0000E+00 0.0000E+00 9.040 0.0000E+00 0.0000E+00 0.0000E+00 9.300 0.0000E+00 0.0000E+00 0.0000E+00 9.560 0.0000E+00 0.0000E+00 0.0000E+00 9.820 0.0000E+00 0.0000E+00 0.0000E+00 10.080 0.0000E+00 0.0000E+00 0.0000E+00 12.000 0.0000E+00 0.0000E+00 0.0000E+00 24.000 0.0000E+00 0.0000E+00 0.0000E+00 96.000 0.0000E+00 0.0000E+00 0.0000E+00 720.000 0.0000E+00 0.0000E+00 0.0000E+00 Cumulative Dose Summary EAB LPZ Control Room Time Thyroid TEDE Thyroid TEDE Thyroid TEDE (hr) (rem) (rem) (rem) (rem) (rem) (rem) 0.001 0.0000E+00 3.3562E-06 0.0000E+00 4.1470E-07 0.0000E+00 7.4069E-10 0.001 4.9052E-11 1.0873E-05 6.0609E-12 1.3434E-06 6.5955E-13 3.2588E-09 0.280 9.4842E-06 6.0313E-03 1.1719E-06 7.4524E-04 4.1502E-05 1.0056E-03 0.333 1.2792E-05 7.1435E-03 1.5805E-06 8.8267E-04 6.4608E-05 1.4628E-03 0.600 3.1818E-05 1.2417E-02 3.9315E-06 1.5343E-03 1.4952E-04 3.1746E-03 0.860 5.0755E-05 1.6997E-02 6.2714E-06 2.1002E-03 1.8459E-04 3.9825E-03 1.120 6.7977E-05 2.1046E-02 8.3994E-06 2.6004E-03 2.0160E-04 4.4422E-03 1.380 8.2972E-05 2.4628E-02 1.0252E-05 3.0431E-03 2.1146E-04 4.7483E-03 1.640 9.5838E-05 2.7818E-02 1.1842E-05 3.4372E-03 2.1823E-04 4.9800E-03 1.900 1.0687E-04 3.0679E-02 1.3205E-05 3.7907E-03 2.2350E-04 5.1714E-03 2.000 1.1070E-04 3.1703E-02 1.3678E-05 3.9173E-03 2.2528E-04 5.2380E-03 2.260 1.1972E-04 3.4197E-02 1.4185E-05 4.0575E-03 2.2936E-04 5.3921E-03 2.520 1.2762E-04 3.6475E-02 1.4629E-05 4.1856E-03 2.3278E-04 5.5231E-03 2.780 1.3461E-04 3.8570E-02 1.5022E-05 4.3033E-03 2.3574E-04 5.6385E-03 3.040 1.4086E-04 4.0505E-02 1.5373E-05 4.4121E-03 2.3838E-04 5.7430E-03 3.300 1.4650E-04 4.2302E-02 1.5690E-05 4.5131E-03 2.4079E-04 5.8392E-03 3.560 1.5162E-04 4.3976E-02 1.5979E-05 4.6073E-03 2.4301E-04 5.9285E-03 3.820 1.5632E-04 4.5542E-02 1.6243E-05 4.6953E-03 2.4506E-04 6.0120E-03 4.080 1.6064E-04 4.7008E-02 1.6486E-05 4.7777E-03 2.4698E-04 6.0904E-03 4.340 1.6464E-04 4.8386E-02 1.6710E-05 4.8551E-03 2.4877E-04 6.1640E-03 4.600 1.6834E-04 4.9682E-02 1.6918E-05 4.9280E-03 2.5044E-04 6.2333E-03 4.860 1.7179E-04 5.0903E-02 1.7112E-05 4.9966E-03 2.5200E-04 6.2985E-03 5.120 1.7500E-04 5.2055E-02 1.7293E-05 5.0614E-03 2.5347E-04 6.3601E-03 5.380 1.7800E-04 5.3143E-02 1.7461E-05 5.1226E-03 2.5485E-04 6.4182E-03 5.640 1.8080E-04 5.4172E-02 1.7619E-05 5.1804E-03 2.5614E-04 6.4730E-03 5.900 1.8342E-04 5.5146E-02 1.7766E-05 5.2352E-03 2.5735E-04 6.5249E-03 6.160 1.8587E-04 5.6069E-02 1.7904E-05 5.2870E-03 2.5848E-04 6.5739E-03 6.420 1.8817E-04 5.6944E-02 1.8033E-05 5.3362E-03 2.5955E-04 6.6202E-03 6.680 1.9032E-04 5.7774E-02 1.8154E-05 5.3829E-03 2.6055E-04 6.6641E-03 6.940 1.9234E-04 5.8562E-02 1.8268E-05 5.4272E-03 2.6148E-04 6.7056E-03 7.200 1.9423E-04 5.9311E-02 1.8374E-05 5.4693E-03 2.6236E-04 6.7449E-03 7.460 1.9601E-04 6.0023E-02 1.8474E-05 5.5094E-03 2.6319E-04 6.7822E-03 7.720 1.9767E-04 6.0701E-02 1.8567E-05 5.5475E-03 2.6396E-04 6.8176E-03 7.980 1.9923E-04 6.1347E-02 1.8655E-05 5.5838E-03 2.6468E-04 6.8512E-03 8.000 1.9935E-04 6.1395E-02 1.8662E-05 5.5865E-03 2.6474E-04 6.8537E-03 8.260 2.0010E-04 6.1997E-02 1.8690E-05 5.6092E-03 2.6535E-04 6.8814E-03 8.520 2.0080E-04 6.2571E-02 1.8717E-05 5.6310E-03 2.6581E-04 6.9016E-03 8.780 2.0146E-04 6.3118E-02 1.8742E-05 5.6517E-03 2.6615E-04 6.9174E-03 9.040 2.0208E-04 6.3642E-02 1.8765E-05 5.6715E-03 2.6643E-04 6.9305E-03 9.300 2.0266E-04 6.4142E-02 1.8787E-05 5.6904E-03 2.6667E-04 6.9421E-03

Numerical Applications Inc. Attachment 4 Page 98 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 9.560 2.0321E-04 6.4621E-02 1.8808E-05 5.7086E-03 2.6688E-04 6.9526E-03 9.820 2.0372E-04 6.5079E-02 1.8827E-05 5.7259E-03 2.6708E-04 6.9624E-03 10.080 2.0420E-04 6.5518E-02 1.8845E-05 5.7425E-03 2.6726E-04 6.9716E-03 12.000 2.0694E-04 6.8265E-02 1.8949E-05 5.8465E-03 2.6826E-04 7.0272E-03 24.000 2.0694E-04 6.8265E-02 1.8949E-05 5.8465E-03 2.6845E-04 7.0375E-03 96.000 2.0694E-04 6.8265E-02 1.8949E-05 5.8465E-03 2.6845E-04 7.0375E-03 720.000 2.0694E-04 6.8265E-02 1.8949E-05 5.8465E-03 2.6845E-04 7.0375E-03 Worst Two-Hour Dose (Provided for Dose Location 1)

EAB Time Whole Body Thyroid Skin TEDE (hr) (rem) (rem) (rem) (rem) 0.0 3.0435E-02 1.1070E-04 6.7886E-02 3.1700E-02 30 Day Control Room Skin Dose Control Room Time Skin (hr) (rem) 720.0 2.7446E-01

Numerical Applications Inc. Attachment 5 Page 99 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Palisades MSLB Iodine Dose (pal_MSLB_iodine_db_ast.out)

RADTRAD-NAI Version 1.1a(QA) run on May 26, 2006 at 14:03:06 File information Plant file name = AST/MSLB/pal_MSLB_iodine_db_ast.psf Inventory file name = AST/MSLB/pal_mslb_db_ast.nif Scenario file name = AST/MSLB/pal_MSLB_iodine_db_ast.psf Release file name = AST/MSLB/pal_mslb_iodine_ast_db.rft Dose conversion file name = AST/MSLB/nai-1101-001rev0.dcf

  • RADTRAD-NAI 1.1a(QA)
  • 26 May 2006 14:02:56
    • Failed Fuel Iodine Activity Dose
  • Nuclide inventory file AST/MSLB/pal_mslb_db_ast.nif
  • Plant power 2703
  • Compartments 5
  • Compartment 1:

PCS 3

432977 0

0 0

0

  • Compartment 2:

Environment 2

2e+20 0

0 0

0

  • Compartment 3:

Control Room 1

35923 0

1 0

0

  • Compartment 4:

Faulted S/G 3

210759 0

0 0

0

Numerical Applications Inc. Attachment 5 Page 100 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1

  • Compartment 5:

Intact S/G 3

141065 0

0 0

0

  • Pathways 8
  • Pathway 1:

Faulted SG Tube Leakage 1

2 2

  • Pathway 2:

Control Room Unfiltered Makeup 2

3 2

  • Pathway 3:

Control Room Filtered Makeup 2

3 2

  • Pathway 4:

Control Room Unfiltered Inleakage 2

3 2

  • Pathway 5:

Control Room Exhaust 3

2 2

  • Pathway 6:

Intact S/G Tube Leakage 1

5 2

  • Pathway 7:

Intact S/G Steam Release 5

2 2

  • Pathway 8:

Faulted S/G Steam Release 4

2 2

  • Sources 5

1 1 2 0 3 0 4 0 5 0

  • dose conversion factors filename AST/MSLB/nai-1101-001rev0.dcf
  • release fraction and timing filename AST/MSLB/pal_mslb_iodine_ast_db.rft 0

1 1

  • Iodine 0 0.97 0.03
  • Overlying pool
  • aerosol model 0
  • elemental model 0
  • organic model 0

Numerical Applications Inc. Attachment 5 Page 101 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1

  • pH tracking 0
  • Compartment detail
  • Compartment 1:

1

  • spray model 0

0 0

  • filter model 0
  • deposition model 0

0

  • Compartment 2:

1

  • spray model 0

0 0

  • filter model 0
  • deposition model 0

0

  • Compartment 3:

1

  • spray model 0

0 0

  • filter model 1

3 0 0 99 99 99 0.3333 1413.6 99 99 99 720 1413.6 99 99 99

  • deposition model 0

0

  • Compartment 4:

1

  • spray model 0

0 0

  • filter model 0
  • deposition model 0

0

  • Compartment 5:

1

  • spray model 0

0 0

  • filter model 0
  • deposition model 0

0

  • Pathways:
  • Pathway 1
  • filter efficiency model 1

3 0 2.5025 0 0 0 12 0 0 0 0 720 0 0 0 0

  • Pathway 2
  • filter efficiency model 1

Numerical Applications Inc. Attachment 5 Page 102 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 3

0 660 0 0 0 0.3333 0 0 0 0 720 0 0 0 0

  • Pathway 3
  • filter efficiency model 1

3 0 0 99 99 99 0.3333 1413.6 99 99 99 720 1413.6 99 99 99

  • Pathway 4
  • filter efficiency model 1

3 0 0 0 0 0 0.3333 10 0 0 0 720 10 0 0 0

  • Pathway 5
  • filter efficiency model 1

3 0 660 0 0 0 0.3333 1423.6 0 0 0 720 1423.6 0 0 0

  • Pathway 6
  • filter efficiency model 1

3 0 2.5025 0 0 0 12 0 0 0 0 720 0 0 0 0

  • Pathway 7
  • filter efficiency model 1

3 0 16.67 0 0 0 8 0 0 0 0 720 0 0 0 0

  • Pathway 8
  • filter efficiency model 1

2 0 1000000 0 0 0 720 1000000 0 0 0

  • x/q tables 6

EAB 2

0 0.000539 720 0.000539 LPZ 6

0 6.66e-05 2 3.03e-05 8 2.04e-05 24 8.67e-06 96 2.54e-06 720 2.54e-06 Control Room Unfiltered 6

0 0.0131 2 0.0113 8 0.00468 24 0.00287 96 0.00236 720 0.00236 Control Room Filtered 6

0 0.000799 2 0.000643 8 0.000258 24 0.000175

Numerical Applications Inc. Attachment 5 Page 103 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 96 0.000132 720 0.000132 ADV-Normal 6

0 0.0165 2 0.0134 8 0.0054 24 0.00403 96 0.00298 720 0.00298 ADV-Emergency 6

0 0.000736 2 0.000642 8 0.000243 24 0.000175 96 0.000128 720 0.000128

  • dose locations 3
  • location name, compartment number and x/q table EAB 2

1

  • br model 1

4 0 0.00035 8 0.00018 24 0.00023 720 0.00023

  • of model 0
  • location x/q input to be included 0
  • location name, compartment number and x/q table LPZ 2

2

  • br model 1

4 0 0.00035 8 0.00018 24 0.00023 720 0.00023

  • of model 0
  • location x/q input to be included 0
  • location name, compartment number and x/q table Control Room 3

0

  • br model 1

2 0 0.00035 720 0.00035

  • of model 1

4 0 1 24 0.6 96 0.4 720 0.4

  • location x/q input to be included 1
  • number of intake combinations 9
  • intake combinations 2 1 3 3 1 4

Numerical Applications Inc. Attachment 5 Page 104 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 4 1 3 2 7 5 3 7 6 4 7 5 2 8 3 3 8 4 4 8 3

  • time step count 1

0 0.02

  • show plant, scenario, event, step, model 1

1 1

0 1

RADTRAD-NAI Version 1.1a(QA) run on May 26, 2006 at 14:03:06 Plant Description Number of Nuclides = 107 Inventory Power = 2.7030E+03 MWth Plant Power Level = 2.7030E+03 MWth Number of compartments = 5 Compartment information Compartment number 1 (Source term fraction = 1.0000E+00)

Name: PCS Compartment volume = 4.3298E+05 (Cubic feet)

Pathways into and out of compartment 1 Pathway to compartment number 2: Faulted SG Tube Leakage Pathway to compartment number 5: Intact S/G Tube Leakage Compartment number 2 Name: Environment Pathways into and out of compartment 2 Pathway to compartment number 3: Control Room Unfiltered Makeup Pathway to compartment number 3: Control Room Filtered Makeup Pathway to compartment number 3: Control Room Unfiltered Inleakage Pathway from compartment number 1: Faulted SG Tube Leakage Pathway from compartment number 3: Control Room Exhaust Pathway from compartment number 5: Intact S/G Steam Release Pathway from compartment number 4: Faulted S/G Steam Release Compartment number 3 Name: Control Room Compartment volume = 3.5923E+04 (Cubic feet)

Removal devices within compartment:

Filter(s)

Pathways into and out of compartment 3 Pathway to compartment number 2: Control Room Exhaust Pathway from compartment number 2: Control Room Unfiltered Makeup Pathway from compartment number 2: Control Room Filtered Makeup Pathway from compartment number 2: Control Room Unfiltered Inleakage Compartment number 4 Name: Faulted S/G Compartment volume = 2.1076E+05 (Cubic feet)

Pathways into and out of compartment 4 Pathway to compartment number 2: Faulted S/G Steam Release Compartment number 5 Name: Intact S/G Compartment volume = 1.4106E+05 (Cubic feet)

Pathways into and out of compartment 5

Numerical Applications Inc. Attachment 5 Page 105 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Pathway to compartment number 2: Intact S/G Steam Release Pathway from compartment number 1: Intact S/G Tube Leakage Total number of pathways = 8 RADTRAD-NAI Version 1.1a(QA) run on May 26, 2006 at 14:03:06 Scenario Description Radioactive Decay is enabled Calculation of Daughters is enabled Iodine fractions Aerosol = 0.0000E+00 Elemental = 9.7000E-01 Organic = 3.0000E-02 COMPARTMENT DATA Compartment number 1: PCS Compartment number 2: Environment Compartment number 3: Control Room Compartment Filter Data Time (hr) Flow Rate Filter Efficiencies (%)

(cfm) Aerosol Elemental Organic 0.0000E+00 0.0000E+00 9.9000E+01 9.9000E+01 9.9000E+01 3.3330E-01 1.4136E+03 9.9000E+01 9.9000E+01 9.9000E+01 7.2000E+02 1.4136E+03 9.9000E+01 9.9000E+01 9.9000E+01 Compartment number 4: Faulted S/G Compartment number 5: Intact S/G PATHWAY DATA Pathway number 1: Faulted SG Tube Leakage Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)

(cfm) Aerosol Elemental Organic 0.0000E+00 2.5025E+00 0.0000E+00 0.0000E+00 0.0000E+00 1.2000E+01 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Pathway number 2: Control Room Unfiltered Makeup Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)

(cfm) Aerosol Elemental Organic 0.0000E+00 6.6000E+02 0.0000E+00 0.0000E+00 0.0000E+00 3.3330E-01 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Pathway number 3: Control Room Filtered Makeup Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)

(cfm) Aerosol Elemental Organic 0.0000E+00 0.0000E+00 9.9000E+01 9.9000E+01 9.9000E+01 3.3330E-01 1.4136E+03 9.9000E+01 9.9000E+01 9.9000E+01 7.2000E+02 1.4136E+03 9.9000E+01 9.9000E+01 9.9000E+01

Numerical Applications Inc. Attachment 5 Page 106 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Pathway number 4: Control Room Unfiltered Inleakage Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)

(cfm) Aerosol Elemental Organic 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 3.3330E-01 1.0000E+01 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 1.0000E+01 0.0000E+00 0.0000E+00 0.0000E+00 Pathway number 5: Control Room Exhaust Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)

(cfm) Aerosol Elemental Organic 0.0000E+00 6.6000E+02 0.0000E+00 0.0000E+00 0.0000E+00 3.3330E-01 1.4236E+03 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 1.4236E+03 0.0000E+00 0.0000E+00 0.0000E+00 Pathway number 6: Intact S/G Tube Leakage Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)

(cfm) Aerosol Elemental Organic 0.0000E+00 2.5025E+00 0.0000E+00 0.0000E+00 0.0000E+00 1.2000E+01 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Pathway number 7: Intact S/G Steam Release Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)

(cfm) Aerosol Elemental Organic 0.0000E+00 1.6670E+01 0.0000E+00 0.0000E+00 0.0000E+00 8.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Pathway number 8: Faulted S/G Steam Release Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)

(cfm) Aerosol Elemental Organic 0.0000E+00 1.0000E+06 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 1.0000E+06 0.0000E+00 0.0000E+00 0.0000E+00 X/Q DATA X/Q table 1: EAB Time (hr) X/Q (s

  • m^-3) 0.0000E+00 5.3900E-04 7.2000E+02 5.3900E-04 X/Q table 2: LPZ Time (hr) X/Q (s
  • m^-3) 0.0000E+00 6.6600E-05 2.0000E+00 3.0300E-05 8.0000E+00 2.0400E-05 2.4000E+01 8.6700E-06 9.6000E+01 2.5400E-06 7.2000E+02 2.5400E-06 X/Q table 3: Control Room Unfiltered Time (hr) X/Q (s
  • m^-3) 0.0000E+00 1.3100E-02 2.0000E+00 1.1300E-02 8.0000E+00 4.6800E-03 2.4000E+01 2.8700E-03 9.6000E+01 2.3600E-03

Numerical Applications Inc. Attachment 5 Page 107 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 7.2000E+02 2.3600E-03 X/Q table 4: Control Room Filtered Time (hr) X/Q (s

  • m^-3) 0.0000E+00 7.9900E-04 2.0000E+00 6.4300E-04 8.0000E+00 2.5800E-04 2.4000E+01 1.7500E-04 9.6000E+01 1.3200E-04 7.2000E+02 1.3200E-04 X/Q table 5: ADV-Normal Time (hr) X/Q (s
  • m^-3) 0.0000E+00 1.6500E-02 2.0000E+00 1.3400E-02 8.0000E+00 5.4000E-03 2.4000E+01 4.0300E-03 9.6000E+01 2.9800E-03 7.2000E+02 2.9800E-03 X/Q table 6: ADV-Emergency Time (hr) X/Q (s
  • m^-3) 0.0000E+00 7.3600E-04 2.0000E+00 6.4200E-04 8.0000E+00 2.4300E-04 2.4000E+01 1.7500E-04 9.6000E+01 1.2800E-04 7.2000E+02 1.2800E-04 LOCATION DATA Location EAB is in compartment 2 Using X/Q Table 1 Location Breathing Rate Data Time (hr) Breathing Rate (m^3
  • sec^-1) 0.0000E+00 3.5000E-04 8.0000E+00 1.8000E-04 2.4000E+01 2.3000E-04 7.2000E+02 2.3000E-04 Location LPZ is in compartment 2 Using X/Q Table 2 Location Breathing Rate Data Time (hr) Breathing Rate (m^3
  • sec^-1) 0.0000E+00 3.5000E-04 8.0000E+00 1.8000E-04 2.4000E+01 2.3000E-04 7.2000E+02 2.3000E-04 Location Control Room is in compartment 3 Inleakage X/Q Table Assignments Inleakage Path Source Path X/Q Table 2 1 3 3 1 4 4 1 3 2 7 5 3 7 6 4 7 5 2 8 3 3 8 4 4 8 3 Location Breathing Rate Data Time (hr) Breathing Rate (m^3
  • sec^-1) 0.0000E+00 3.5000E-04 7.2000E+02 3.5000E-04 Location Occupancy Factor Data

Numerical Applications Inc. Attachment 5 Page 108 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Time (hr) Occupancy Factor 0.0000E+00 1.0000E+00 2.4000E+01 6.0000E-01 9.6000E+01 4.0000E-01 7.2000E+02 4.0000E-01 USER SPECIFIED TIME STEP DATA - SUPPLEMENTAL TIME STEPS Time Time step 0.0000E+00 2.0000E-02 RADTRAD-NAI Version 1.1a(QA) run on May 26, 2006 at 14:03:06 Dose, Detailed Model and Detailed Inventory Output Detailed model information at time (H) = 0.0010 EAB Doses:

Time (h) = 0.0010 Whole Body Thyroid Skin TEDE Delta dose (rem) 8.2988E-05 1.0894E-02 1.4669E-04 6.3436E-04 Accumulated dose (rem) 8.2988E-05 1.0894E-02 1.4669E-04 6.3436E-04 LPZ Doses:

Time (h) = 0.0010 Whole Body Thyroid Skin TEDE Delta dose (rem) 1.0254E-05 1.3461E-03 1.8126E-05 7.8383E-05 Accumulated dose (rem) 1.0254E-05 1.3461E-03 1.8126E-05 7.8383E-05 Control Room Doses:

Time (h) = 0.0010 Whole Body Thyroid Skin TEDE Delta dose (rem) 2.4823E-08 1.1032E-04 1.4854E-06 5.6084E-06 Accumulated dose (rem) 2.4823E-08 1.1032E-04 1.4854E-06 5.6084E-06 PCS Compartment Atmosphere Nuclide Inventory:

Time (h) = 0.0010 Ci kg Atoms Bq Rb-86 9.5912E+02 1.1788E-05 8.2542E+19 3.5488E+13 Sr-89 1.4517E-01 4.9967E-09 3.3810E+16 5.3711E+09 I-131 2.4419E+05 1.9697E-03 9.0546E+21 9.0349E+15 I-132 2.1782E+05 2.1102E-05 9.6274E+19 8.0594E+15 I-133 2.9824E+05 2.6327E-04 1.1921E+21 1.1035E+16 I-134 3.2660E+05 1.2243E-05 5.5021E+19 1.2084E+16 I-135 2.7986E+05 7.9690E-05 3.5548E+20 1.0355E+16 Xe-133 1.2009E+00 6.4156E-09 2.9050E+16 4.4433E+10 Xe-135 1.3598E+01 5.3247E-09 2.3753E+16 5.0312E+11 Cs-134 9.9731E+04 7.7082E-02 3.4642E+23 3.6901E+15 Cs-136 2.8754E+04 3.9233E-04 1.7372E+21 1.0639E+15 Cs-137 5.3856E+04 6.1916E-01 2.7217E+24 1.9927E+15 I-130 7.6353E+03 3.9149E-06 1.8135E+19 2.8251E+14 Kr-83m 5.2952E+00 2.5665E-10 1.8621E+15 1.9592E+11 Xe-131m 4.9540E-03 5.9145E-11 2.7189E+14 1.8330E+08 Xe-133m 8.5976E-02 1.9161E-10 8.6759E+14 3.1811E+09 Xe-135m 8.8242E+01 9.6871E-10 4.3213E+15 3.2650E+12 Cs-138 6.5541E+05 1.5489E-05 6.7592E+19 2.4250E+16 Cs-134m 2.4083E+04 2.9863E-06 1.3421E+19 8.9105E+14

Numerical Applications Inc. Attachment 5 Page 109 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Rb-88 2.6240E+05 2.1860E-06 1.4959E+19 9.7089E+15 Rb-89 3.3666E+05 2.4221E-06 1.6389E+19 1.2456E+16 Ba-137m 6.2342E+02 1.1592E-09 5.0955E+15 2.3066E+13 Br-82 1.0775E+03 9.9526E-07 7.3093E+18 3.9868E+13 Br-83 1.8563E+04 1.1750E-06 8.5255E+18 6.8682E+14 Br-84 3.2414E+04 4.6049E-07 3.3013E+18 1.1993E+15 PCS Transport Group Inventory:

Overlying Time (h) = 0.0010 Atmosphere Sump Pool Noble gases (atoms) 6.0125E+16 0.0000E+00 0.0000E+00 Elemental I (atoms) 1.0467E+22 0.0000E+00 0.0000E+00 Organic I (atoms) 3.2372E+20 0.0000E+00 0.0000E+00 Aerosols (kg) 6.9667E-01 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 0.0010 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Faulted SG Tube Leakage Transport Group Inventory:

Pathway Time (h) = 0.0010 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Tube Leakage Transport Group Inventory:

Pathway Time (h) = 0.0010 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Environment Integral Nuclide Release:

Time (h) = 0.0010 Ci kg Atoms Bq Rb-86 1.1451E-04 1.4073E-12 9.8545E+12 4.2368E+06 Sr-89 1.9362E-08 6.6645E-16 4.5095E+09 7.1639E+02 I-131 2.9153E-02 2.3515E-10 1.0810E+15 1.0787E+09 I-132 2.6005E-02 2.5193E-12 1.1494E+13 9.6217E+08 I-133 3.5606E-02 3.1432E-11 1.4232E+14 1.3174E+09 I-134 3.8990E-02 1.4616E-12 6.5685E+12 1.4426E+09 I-135 3.3412E-02 9.5140E-12 4.2440E+13 1.2362E+09 Xe-133 1.6016E-07 8.5564E-16 3.8743E+09 5.9259E+03 Xe-135 1.8135E-06 7.1015E-16 3.1679E+09 6.7101E+04 Cs-134 1.1907E-02 9.2027E-09 4.1358E+16 4.4055E+08 Cs-136 3.4329E-03 4.6839E-11 2.0741E+14 1.2702E+08 Cs-137 6.4297E-03 7.3921E-08 3.2493E+17 2.3790E+08 I-130 9.1156E-04 4.6739E-13 2.1651E+12 3.3728E+07 Kr-83m 7.0621E-07 3.4229E-17 2.4835E+08 2.6130E+04 Xe-131m 6.6071E-10 7.8880E-18 3.6261E+07 2.4446E+01 Xe-133m 1.1466E-08 2.5555E-17 1.1571E+08 4.2426E+02 Xe-135m 1.1768E-05 1.2919E-16 5.7628E+08 4.3541E+05 Cs-138 7.8239E-02 1.8490E-12 8.0688E+12 2.8949E+09 Cs-134m 2.8752E-03 3.5653E-13 1.6023E+12 1.0638E+08 Rb-88 3.1321E-02 2.6093E-13 1.7856E+12 1.1589E+09 Rb-89 4.0193E-02 2.8917E-13 1.9567E+12 1.4871E+09 Ba-137m 8.3107E-05 1.5453E-16 6.7927E+08 3.0749E+06 Br-82 1.2864E-04 1.1882E-13 8.7264E+11 4.7597E+06 Br-83 2.2162E-03 1.4028E-13 1.0178E+12 8.1998E+07 Br-84 3.8698E-03 5.4976E-14 3.9414E+11 1.4318E+08 Environment Transport Group Inventory:

Present Release Integral

Numerical Applications Inc. Attachment 5 Page 110 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Time (h) = 0.0010 Release Rate/s Release Noble gases (atoms) 8.0187E+09 4.0094E+09 8.0187E+09 Elemental I (atoms) 1.2496E+15 6.2482E+14 1.2496E+15 Organic I (atoms) 3.8648E+13 1.9324E+13 3.8648E+13 Aerosols (kg) 8.3174E-08 4.1587E-08 8.3174E-08 Faulted SG Tube Leakage Transport Group Inventory:

Pathway Time (h) = 0.0010 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:

Pathway Time (h) = 0.0010 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Filtered Makeup Transport Group Inventory:

Pathway Time (h) = 0.0010 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Inleakage Transport Group Inventory:

Pathway Time (h) = 0.0010 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:

Pathway Time (h) = 0.0010 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 0.0010 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Faulted S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 0.0010 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Compartment Atmosphere Nuclide Inventory:

Time (h) = 0.0010 Ci kg Atoms Bq Rb-86 6.7835E-07 8.3369E-15 5.8379E+10 2.5099E+04

Numerical Applications Inc. Attachment 5 Page 111 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Sr-89 1.2138E-10 4.1781E-18 2.8271E+07 4.4912E+00 I-131 1.7270E-04 1.3931E-12 6.4040E+12 6.3901E+06 I-132 1.5405E-04 1.4924E-14 6.8088E+10 5.6999E+06 I-133 2.1093E-04 1.8620E-13 8.4312E+11 7.8045E+06 I-134 2.3097E-04 8.6582E-15 3.8911E+10 8.5460E+06 I-135 1.9793E-04 5.6362E-14 2.5142E+11 7.3235E+06 Xe-133 1.0040E-09 5.3639E-18 2.4287E+07 3.7149E+01 Xe-135 1.1369E-08 4.4519E-18 1.9859E+07 4.2065E+02 Cs-134 7.0536E-05 5.4518E-11 2.4501E+14 2.6098E+06 Cs-136 2.0337E-05 2.7748E-13 1.2287E+12 7.5246E+05 Cs-137 3.8090E-05 4.3791E-10 1.9249E+15 1.4093E+06 I-130 5.4002E-06 2.7688E-15 1.2826E+10 1.9981E+05 Kr-83m 4.4272E-09 2.1458E-19 1.5569E+06 1.6381E+02 Xe-131m 4.1419E-12 4.9449E-20 2.2732E+05 1.5325E-01 Xe-133m 7.1882E-11 1.6020E-19 7.2537E+05 2.6596E+00 Xe-135m 7.3769E-08 8.0983E-19 3.6125E+06 2.7295E+03 Cs-138 4.6347E-04 1.0953E-14 4.7798E+10 1.7148E+07 Cs-134m 1.7033E-05 2.1121E-15 9.4921E+09 6.3021E+05 Rb-88 1.8553E-04 1.5456E-15 1.0577E+10 6.8646E+06 Rb-89 2.3810E-04 1.7131E-15 1.1591E+10 8.8099E+06 Ba-137m 5.2088E-07 9.6853E-19 4.2574E+06 1.9272E+04 Br-82 7.6208E-07 7.0391E-16 5.1696E+09 2.8197E+04 Br-83 1.3129E-05 8.3105E-16 6.0297E+09 4.8576E+05 Br-84 2.2925E-05 3.2568E-16 2.3349E+09 8.4823E+05 Control Room Transport Group Inventory:

Overlying Time (h) = 0.0010 Atmosphere Sump Pool Noble gases (atoms) 5.0269E+07 0.0000E+00 0.0000E+00 Elemental I (atoms) 7.4029E+12 0.0000E+00 0.0000E+00 Organic I (atoms) 2.2896E+11 0.0000E+00 0.0000E+00 Aerosols (kg) 4.9273E-10 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 0.0010 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:

Pathway Time (h) = 0.0010 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Filtered Makeup Transport Group Inventory:

Pathway Time (h) = 0.0010 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Inleakage Transport Group Inventory:

Pathway Time (h) = 0.0010 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:

Pathway Time (h) = 0.0010 Filter Noble gases (atoms) 0.0000E+00

Numerical Applications Inc. Attachment 5 Page 112 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Faulted S/G Transport Group Inventory:

Overlying Time (h) = 0.0010 Atmosphere Sump Pool Noble gases (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 0.0010 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Faulted S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 0.0010 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Compartment Atmosphere Nuclide Inventory:

Time (h) = 0.0010 Ci kg Atoms Bq Rb-86 1.6630E-04 2.0439E-12 1.4312E+13 6.1533E+06 Sr-89 2.9759E-08 1.0243E-15 6.9311E+09 1.1011E+03 I-131 4.2340E-02 3.4152E-10 1.5700E+15 1.5666E+09 I-132 3.7767E-02 3.6588E-12 1.6692E+13 1.3974E+09 I-133 5.1712E-02 4.5650E-11 2.0670E+14 1.9134E+09 I-134 5.6625E-02 2.1226E-12 9.5394E+12 2.0951E+09 I-135 4.8525E-02 1.3818E-11 6.1638E+13 1.7954E+09 Xe-133 2.4615E-07 1.3150E-15 5.9544E+09 9.1076E+03 Xe-135 2.7873E-06 1.0915E-15 4.8688E+09 1.0313E+05 Cs-134 1.7293E-02 1.3365E-08 6.0066E+16 6.3983E+08 Cs-136 4.9857E-03 6.8027E-11 3.0123E+14 1.8447E+08 Cs-137 9.3382E-03 1.0736E-07 4.7192E+17 3.4551E+08 I-130 1.3239E-03 6.7880E-13 3.1445E+12 4.8984E+07 Kr-83m 1.0854E-06 5.2607E-17 3.8169E+08 4.0159E+04 Xe-131m 1.0155E-09 1.2123E-17 5.5731E+07 3.7572E+01 Xe-133m 1.7623E-08 3.9275E-17 1.7784E+08 6.5205E+02 Xe-135m 1.8086E-05 1.9854E-16 8.8566E+08 6.6917E+05 Cs-138 1.1362E-01 2.6852E-12 1.1718E+13 4.2041E+09 Cs-134m 4.1757E-03 5.1780E-13 2.3271E+12 1.5450E+08 Rb-88 4.5484E-02 3.7891E-13 2.5930E+12 1.6829E+09 Rb-89 5.8374E-02 4.1998E-13 2.8418E+12 2.1598E+09 Ba-137m 1.2770E-04 2.3745E-16 1.0438E+09 4.7249E+06 Br-82 1.8683E-04 1.7257E-13 1.2674E+12 6.9128E+06 Br-83 3.2186E-03 2.0374E-13 1.4782E+12 1.1909E+08 Br-84 5.6203E-03 7.9845E-14 5.7242E+11 2.0795E+08 Intact S/G Transport Group Inventory:

Overlying Time (h) = 0.0010 Atmosphere Sump Pool Noble gases (atoms) 1.2324E+10 0.0000E+00 0.0000E+00 Elemental I (atoms) 1.8149E+15 0.0000E+00 0.0000E+00 Organic I (atoms) 5.6131E+13 0.0000E+00 0.0000E+00 Aerosols (kg) 1.2080E-07 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 0.0010 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00

Numerical Applications Inc. Attachment 5 Page 113 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Intact S/G Tube Leakage Transport Group Inventory:

Pathway Time (h) = 0.0010 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 0.0010 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Detailed model information at time (H) = 0.3333 EAB Doses:

Time (h) = 0.3333 Whole Body Thyroid Skin TEDE Delta dose (rem) 4.7557E-02 7.2378E+00 8.2132E-02 4.1353E-01 Accumulated dose (rem) 4.7640E-02 7.2487E+00 8.2278E-02 4.1417E-01 LPZ Doses:

Time (h) = 0.3333 Whole Body Thyroid Skin TEDE Delta dose (rem) 5.8763E-03 8.9432E-01 1.0148E-02 5.1097E-02 Accumulated dose (rem) 5.8865E-03 8.9566E-01 1.0167E-02 5.1176E-02 Control Room Doses:

Time (h) = 0.3333 Whole Body Thyroid Skin TEDE Delta dose (rem) 5.3082E-03 2.8771E+01 3.0780E-01 1.4597E+00 Accumulated dose (rem) 5.3082E-03 2.8771E+01 3.0781E-01 1.4597E+00 PCS Compartment Atmosphere Nuclide Inventory:

Time (h) = 0.3333 Ci kg Atoms Bq Rb-86 9.5841E+02 1.1779E-05 8.2481E+19 3.5461E+13 Sr-89 4.2152E+01 1.4509E-06 9.8175E+18 1.5596E+12 I-131 2.4384E+05 1.9668E-03 9.0417E+21 9.0221E+15 I-132 1.9702E+05 1.9087E-05 8.7080E+19 7.2897E+15 I-133 2.9489E+05 2.6032E-04 1.1787E+21 1.0911E+16 I-134 2.5108E+05 9.4119E-06 4.2298E+19 9.2899E+15 I-135 2.7021E+05 7.6943E-05 3.4323E+20 9.9979E+15 Xe-133 5.2762E+02 2.8188E-06 1.2763E+19 1.9522E+13 Xe-135 6.1860E+03 2.4223E-06 1.0806E+19 2.2888E+14 Cs-134 9.9708E+04 7.7064E-02 3.4634E+23 3.6892E+15 Cs-136 2.8726E+04 3.9195E-04 1.7356E+21 1.0629E+15 Cs-137 5.3844E+04 6.1902E-01 2.7210E+24 1.9922E+15 I-130 7.4926E+03 3.8417E-06 1.7796E+19 2.7723E+14 Kr-83m 2.1027E+03 1.0192E-07 7.3946E+17 7.7802E+13 Xe-131m 2.1883E+00 2.6125E-08 1.2010E+17 8.0966E+10 Xe-133m 3.7727E+01 8.4079E-08 3.8070E+17 1.3959E+12 Xe-135m 2.5841E+04 2.8368E-07 1.2655E+18 9.5613E+14 Cs-138 4.2659E+05 1.0082E-05 4.3994E+19 1.5784E+16 Cs-134m 2.2239E+04 2.7577E-06 1.2393E+19 8.2283E+14 Rb-88 1.2069E+05 1.0054E-06 6.8806E+18 4.4656E+15 Rb-89 1.3559E+05 9.7551E-07 6.6008E+18 5.0168E+15 Ba-137m 5.8833E+04 1.0939E-07 4.8087E+17 2.1768E+15 Br-82 1.0703E+03 9.8856E-07 7.2600E+18 3.9599E+13 Br-83 1.6853E+04 1.0668E-06 7.7404E+18 6.2357E+14 Br-84 2.0984E+04 2.9811E-07 2.1372E+18 7.7641E+14 PCS Transport Group Inventory:

Overlying Time (h) = 0.3333 Atmosphere Sump Pool Noble gases (atoms) 2.6075E+19 0.0000E+00 0.0000E+00

Numerical Applications Inc. Attachment 5 Page 114 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Elemental I (atoms) 1.0406E+22 0.0000E+00 0.0000E+00 Organic I (atoms) 3.2184E+20 0.0000E+00 0.0000E+00 Aerosols (kg) 6.9650E-01 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 0.3333 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Faulted SG Tube Leakage Transport Group Inventory:

Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Tube Leakage Transport Group Inventory:

Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Environment Integral Nuclide Release:

Time (h) = 0.3333 Ci kg Atoms Bq Rb-86 1.1032E-01 1.3559E-09 9.4945E+15 4.0820E+09 Sr-89 4.8522E-03 1.6702E-10 1.1301E+15 1.7953E+08 I-131 2.8069E+01 2.2641E-07 1.0408E+18 1.0385E+12 I-132 2.2679E+01 2.1971E-09 1.0024E+16 8.3913E+11 I-133 3.3945E+01 2.9965E-08 1.3568E+17 1.2560E+12 I-134 2.8902E+01 1.0834E-09 4.8690E+15 1.0694E+12 I-135 3.1104E+01 8.8570E-09 3.9510E+16 1.1509E+12 Xe-133 6.0735E-02 3.2447E-10 1.4692E+15 2.2472E+09 Xe-135 7.1208E-01 2.7884E-10 1.2439E+15 2.6347E+10 Cs-134 1.1477E+01 8.8709E-06 3.9867E+19 4.2467E+11 Cs-136 3.3067E+00 4.5118E-08 1.9978E+17 1.2235E+11 Cs-137 6.1980E+00 7.1256E-05 3.1322E+20 2.2933E+11 I-130 8.6248E-01 4.4222E-10 2.0486E+15 3.1912E+10 Kr-83m 2.4205E-01 1.1732E-11 8.5121E+13 8.9558E+09 Xe-131m 2.5190E-04 3.0073E-12 1.3825E+13 9.3201E+06 Xe-133m 4.3428E-03 9.6784E-12 4.3823E+13 1.6068E+08 Xe-135m 2.9746E+00 3.2655E-11 1.4567E+14 1.1006E+11 Cs-138 4.9106E+01 1.1605E-09 5.0643E+15 1.8169E+12 Cs-134m 2.5599E+00 3.1744E-10 1.4266E+15 9.4717E+10 Rb-88 1.3893E+01 1.1574E-10 7.9204E+14 5.1404E+11 Rb-89 1.5608E+01 1.1229E-10 7.5982E+14 5.7749E+11 Ba-137m 6.7723E+00 1.2593E-11 5.5354E+13 2.5058E+11 Br-82 1.2320E-01 1.1379E-10 8.3571E+14 4.5583E+09 Br-83 1.9400E+00 1.2280E-10 8.9101E+14 7.1780E+10 Br-84 2.4155E+00 3.4316E-11 2.4602E+14 8.9374E+10 Environment Transport Group Inventory:

Present Release Integral Time (h) = 0.3333 Release Rate/s Release Noble gases (atoms) 1.2020E+14 1.6694E+12 3.0015E+15 Elemental I (atoms) 4.7969E+16 6.6624E+14 1.1979E+18 Organic I (atoms) 1.4836E+15 2.0605E+13 3.7047E+16 Aerosols (kg) 3.2107E-06 4.4593E-08 8.0176E-05 Faulted SG Tube Leakage Transport Group Inventory:

Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00

Numerical Applications Inc. Attachment 5 Page 115 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:

Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Filtered Makeup Transport Group Inventory:

Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Inleakage Transport Group Inventory:

Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:

Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Faulted S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Compartment Atmosphere Nuclide Inventory:

Time (h) = 0.3333 Ci kg Atoms Bq Rb-86 3.7845E-04 4.6511E-12 3.2569E+13 1.4003E+07 Sr-89 1.6645E-05 5.7292E-13 3.8766E+12 6.1585E+05 I-131 9.6285E-02 7.7665E-10 3.5703E+15 3.5625E+09 I-132 7.7797E-02 7.5369E-12 3.4385E+13 2.8785E+09 I-133 1.1644E-01 1.0279E-10 4.6543E+14 4.3084E+09 I-134 9.9143E-02 3.7164E-12 1.6702E+13 3.6683E+09 I-135 1.0670E-01 3.0382E-11 1.3553E+14 3.9478E+09 Xe-133 2.0834E-04 1.1130E-12 5.0398E+12 7.7086E+06 Xe-135 2.4427E-03 9.5651E-13 4.2668E+12 9.0378E+07 Cs-134 3.9371E-02 3.0430E-08 1.3676E+17 1.4567E+09 Cs-136 1.1343E-02 1.5477E-10 6.8532E+14 4.1970E+08 Cs-137 2.1261E-02 2.4443E-07 1.0745E+18 7.8666E+08 I-130 2.9586E-03 1.5170E-12 7.0272E+12 1.0947E+08

Numerical Applications Inc. Attachment 5 Page 116 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Kr-83m 8.3031E-04 4.0244E-14 2.9199E+11 3.0721E+07 Xe-131m 8.6408E-07 1.0316E-14 4.7423E+10 3.1971E+04 Xe-133m 1.4897E-05 3.3200E-14 1.5033E+11 5.5119E+05 Xe-135m 1.0204E-02 1.1202E-13 4.9969E+11 3.7755E+08 Cs-138 1.6845E-01 3.9809E-12 1.7372E+13 6.2326E+09 Cs-134m 8.7813E-03 1.0889E-12 4.8937E+12 3.2491E+08 Rb-88 4.7658E-02 3.9702E-13 2.7169E+12 1.7633E+09 Rb-89 5.3540E-02 3.8520E-13 2.6064E+12 1.9810E+09 Ba-137m 2.3231E-02 4.3197E-14 1.8988E+11 8.5955E+08 Br-82 4.2261E-04 3.9035E-13 2.8668E+12 1.5637E+07 Br-83 6.6549E-03 4.2125E-13 3.0564E+12 2.4623E+08 Br-84 8.2860E-03 1.1771E-13 8.4392E+11 3.0658E+08 Control Room Transport Group Inventory:

Overlying Time (h) = 0.3333 Atmosphere Sump Pool Noble gases (atoms) 1.0296E+13 0.0000E+00 0.0000E+00 Elemental I (atoms) 4.1090E+15 0.0000E+00 0.0000E+00 Organic I (atoms) 1.2708E+14 0.0000E+00 0.0000E+00 Aerosols (kg) 2.7503E-07 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 0.3333 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:

Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Filtered Makeup Transport Group Inventory:

Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Inleakage Transport Group Inventory:

Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:

Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Faulted S/G Transport Group Inventory:

Overlying Time (h) = 0.3333 Atmosphere Sump Pool Noble gases (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00

Numerical Applications Inc. Attachment 5 Page 117 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Deposition Recirculating Time (h) = 0.3333 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Faulted S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Compartment Atmosphere Nuclide Inventory:

Time (h) = 0.3333 Ci kg Atoms Bq Rb-86 1.1049E-01 1.3579E-09 9.5090E+15 4.0882E+09 Sr-89 4.8596E-03 1.6727E-10 1.1318E+15 1.7981E+08 I-131 2.8112E+01 2.2675E-07 1.0424E+18 1.0401E+12 I-132 2.2714E+01 2.2005E-09 1.0039E+16 8.4041E+11 I-133 3.3997E+01 3.0011E-08 1.3589E+17 1.2579E+12 I-134 2.8946E+01 1.0851E-09 4.8764E+15 1.0710E+12 I-135 3.1152E+01 8.8705E-09 3.9570E+16 1.1526E+12 Xe-133 6.0828E-02 3.2497E-10 1.4714E+15 2.2506E+09 Xe-135 7.1317E-01 2.7927E-10 1.2458E+15 2.6387E+10 Cs-134 1.1495E+01 8.8845E-06 3.9928E+19 4.2532E+11 Cs-136 3.3118E+00 4.5187E-08 2.0009E+17 1.2254E+11 Cs-137 6.2075E+00 7.1365E-05 3.1370E+20 2.2968E+11 I-130 8.6380E-01 4.4290E-10 2.0517E+15 3.1961E+10 Kr-83m 2.4242E-01 1.1750E-11 8.5251E+13 8.9695E+09 Xe-131m 2.5228E-04 3.0119E-12 1.3846E+13 9.3344E+06 Xe-133m 4.3494E-03 9.6932E-12 4.3890E+13 1.6093E+08 Xe-135m 2.9792E+00 3.2705E-11 1.4589E+14 1.1023E+11 Cs-138 4.9181E+01 1.1623E-09 5.0720E+15 1.8197E+12 Cs-134m 2.5638E+00 3.1792E-10 1.4288E+15 9.4862E+10 Rb-88 1.3914E+01 1.1592E-10 7.9325E+14 5.1483E+11 Rb-89 1.5632E+01 1.1246E-10 7.6098E+14 5.7837E+11 Ba-137m 6.7827E+00 1.2612E-11 5.5438E+13 2.5096E+11 Br-82 1.2339E-01 1.1397E-10 8.3699E+14 4.5653E+09 Br-83 1.9430E+00 1.2299E-10 8.9237E+14 7.1890E+10 Br-84 2.4192E+00 3.4368E-11 2.4639E+14 8.9511E+10 Intact S/G Transport Group Inventory:

Overlying Time (h) = 0.3333 Atmosphere Sump Pool Noble gases (atoms) 3.0061E+15 0.0000E+00 0.0000E+00 Elemental I (atoms) 1.1997E+18 0.0000E+00 0.0000E+00 Organic I (atoms) 3.7104E+16 0.0000E+00 0.0000E+00 Aerosols (kg) 8.0298E-05 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 0.3333 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Intact S/G Tube Leakage Transport Group Inventory:

Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Steam Release Transport Group Inventory:

Numerical Applications Inc. Attachment 5 Page 118 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Detailed model information at time (H) = 2.0000 EAB Doses:

Time (h) = 2.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 1.2659E-01 3.6202E+01 2.0047E-01 1.9557E+00 Accumulated dose (rem) 1.7424E-01 4.3451E+01 2.8275E-01 2.3699E+00 LPZ Doses:

Time (h) = 2.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 1.5642E-02 4.4732E+00 2.4771E-02 2.4165E-01 Accumulated dose (rem) 2.1529E-02 5.3689E+00 3.4937E-02 2.9283E-01 Control Room Doses:

Time (h) = 2.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 5.3342E-03 3.7411E+01 2.9716E-01 1.8949E+00 Accumulated dose (rem) 1.0642E-02 6.6182E+01 6.0496E-01 3.3547E+00 PCS Compartment Atmosphere Nuclide Inventory:

Time (h) = 2.0000 Ci kg Atoms Bq Rb-86 9.5484E+02 1.1735E-05 8.2173E+19 3.5329E+13 Sr-89 7.0054E+01 2.4113E-06 1.6316E+19 2.5920E+12 I-131 2.4210E+05 1.9529E-03 8.9774E+21 8.9579E+15 I-132 1.1909E+05 1.1537E-05 5.2635E+19 4.4062E+15 I-133 2.7863E+05 2.4597E-04 1.1137E+21 1.0309E+16 I-134 6.7142E+04 2.5169E-06 1.1311E+19 2.4843E+15 I-135 2.2662E+05 6.4530E-05 2.8786E+20 8.3850E+15 Xe-133 3.0650E+03 1.6374E-05 7.4142E+19 1.1340E+14 Xe-135 3.4683E+04 1.3581E-05 6.0585E+19 1.2833E+15 Cs-134 9.9587E+04 7.6971E-02 3.4592E+23 3.6847E+15 Cs-136 2.8588E+04 3.9006E-04 1.7272E+21 1.0578E+15 Cs-137 5.3781E+04 6.1830E-01 2.7179E+24 1.9899E+15 I-130 6.8161E+03 3.4948E-06 1.6190E+19 2.5220E+14 Kr-83m 7.2323E+03 3.5054E-07 2.5433E+18 2.6759E+14 Xe-131m 1.3058E+01 1.5590E-07 7.1668E+17 4.8316E+11 Xe-133m 2.1767E+02 4.8511E-07 2.1965E+18 8.0538E+12 Xe-135m 3.7096E+04 4.0723E-07 1.8166E+18 1.3725E+15 Cs-138 4.9501E+04 1.1698E-06 5.1051E+18 1.8316E+15 Cs-134m 1.4914E+04 1.8494E-06 8.3114E+18 5.5182E+14 Rb-88 2.4545E+03 2.0448E-08 1.3993E+17 9.0817E+13 Rb-89 1.4165E+03 1.0191E-08 6.8959E+16 5.2411E+13 Ba-137m 5.9618E+04 1.1085E-07 4.8729E+17 2.2059E+15 Br-82 1.0346E+03 9.5562E-07 7.0182E+18 3.8280E+13 Br-83 1.0381E+04 6.5714E-07 4.7680E+18 3.8411E+14 Br-84 2.3699E+03 3.3668E-08 2.4137E+17 8.7687E+13 PCS Transport Group Inventory:

Overlying Time (h) = 2.0000 Atmosphere Sump Pool Noble gases (atoms) 1.4200E+20 0.0000E+00 0.0000E+00 Elemental I (atoms) 1.0157E+22 0.0000E+00 0.0000E+00 Organic I (atoms) 3.1413E+20 0.0000E+00 0.0000E+00 Aerosols (kg) 6.9568E-01 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 2.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Faulted SG Tube Leakage Transport Group Inventory:

Numerical Applications Inc. Attachment 5 Page 119 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Tube Leakage Transport Group Inventory:

Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Environment Integral Nuclide Release:

Time (h) = 2.0000 Ci kg Atoms Bq Rb-86 6.6666E-01 8.1932E-09 5.7373E+16 2.4667E+10 Sr-89 4.8912E-02 1.6836E-09 1.1392E+16 1.8097E+09 I-131 1.6904E+02 1.3635E-06 6.2679E+18 6.2543E+12 I-132 8.3146E+01 8.0551E-09 3.6749E+16 3.0764E+12 I-133 1.9454E+02 1.7173E-07 7.7759E+17 7.1980E+12 I-134 4.6878E+01 1.7573E-09 7.8974E+15 1.7345E+12 I-135 1.5823E+02 4.5055E-08 2.0098E+17 5.8543E+12 Xe-133 2.1411E+00 1.1438E-08 5.1792E+16 7.9219E+10 Xe-135 2.4228E+01 9.4875E-09 4.2322E+16 8.9645E+11 Cs-134 6.9531E+01 5.3741E-05 2.4152E+20 2.5727E+12 Cs-136 1.9960E+01 2.7234E-07 1.2059E+18 7.3852E+11 Cs-137 3.7550E+01 4.3170E-04 1.8976E+21 1.3893E+12 I-130 4.7590E+00 2.4401E-09 1.1303E+16 1.7608E+11 Kr-83m 5.0521E+00 2.4487E-10 1.7767E+15 1.8693E+11 Xe-131m 9.1219E-03 1.0890E-10 5.0064E+14 3.3751E+08 Xe-133m 1.5206E-01 3.3887E-10 1.5344E+15 5.6260E+09 Xe-135m 2.5908E+01 2.8442E-10 1.2687E+15 9.5860E+11 Cs-138 3.4562E+01 8.1678E-10 3.5643E+15 1.2788E+12 Cs-134m 1.0413E+01 1.2912E-09 5.8030E+15 3.8528E+11 Rb-88 1.7137E+00 1.4276E-11 9.7699E+13 6.3408E+10 Rb-89 9.8900E-01 7.1155E-12 4.8147E+13 3.6593E+10 Ba-137m 4.1625E+01 7.7398E-11 3.4022E+14 1.5401E+12 Br-82 7.2235E-01 6.6721E-10 4.9001E+15 2.6727E+10 Br-83 7.2483E+00 4.5882E-10 3.3290E+15 2.6819E+11 Br-84 1.6547E+00 2.3507E-11 1.6853E+14 6.1223E+10 Environment Transport Group Inventory:

Present Release Integral Time (h) = 2.0000 Release Rate/s Release Noble gases (atoms) 9.9918E+14 1.3877E+13 9.9195E+16 Elemental I (atoms) 7.1394E+16 9.9158E+14 7.0915E+18 Organic I (atoms) 2.2080E+15 3.0667E+13 2.1933E+17 Aerosols (kg) 4.8900E-06 6.7916E-08 4.8572E-04 Faulted SG Tube Leakage Transport Group Inventory:

Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:

Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00

Numerical Applications Inc. Attachment 5 Page 120 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Filter Pathway Nuclide Inventory for Control Room Filtered Makeup Time (h) = 2.0000 Ci kg Atoms Bq Rb-86 2.9362E-04 3.6085E-12 2.5269E+13 1.0864E+07 Sr-89 2.1542E-05 7.4149E-13 5.0173E+12 7.9705E+05 I-131 7.4448E-02 6.0051E-10 2.7606E+15 2.7546E+09 I-132 3.6620E-02 3.5477E-12 1.6185E+13 1.3549E+09 I-133 8.5681E-02 7.5636E-11 3.4247E+14 3.1702E+09 I-134 2.0646E-02 7.7395E-13 3.4782E+12 7.6392E+08 I-135 6.9687E-02 1.9843E-11 8.8518E+13 2.5784E+09 Cs-134 3.0624E-02 2.3669E-08 1.0637E+17 1.1331E+09 Cs-136 8.7910E-03 1.1995E-10 5.3113E+14 3.2527E+08 Cs-137 1.6538E-02 1.9013E-07 8.3576E+17 6.1190E+08 I-130 2.0960E-03 1.0747E-12 4.9784E+12 7.7552E+07 Cs-138 1.5222E-02 3.5973E-13 1.5698E+12 5.6321E+08 Cs-134m 4.5862E-03 5.6870E-13 2.5558E+12 1.6969E+08 Rb-88 7.5477E-04 6.2877E-15 4.3029E+10 2.7927E+07 Rb-89 4.3558E-04 3.1339E-15 2.1205E+10 1.6117E+07 Ba-137m 1.8333E-02 3.4088E-14 1.4984E+11 6.7831E+08 Br-82 3.1814E-04 2.9386E-13 2.1581E+12 1.1771E+07 Br-83 3.1923E-03 2.0207E-13 1.4662E+12 1.1812E+08 Br-84 7.2876E-04 1.0353E-14 7.4224E+10 2.6964E+07 Control Room Filtered Makeup Transport Group Inventory:

Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 3.1233E+15 Organic I (atoms) 9.6597E+13 Aerosols (kg) 2.1393E-07 Control Room Unfiltered Inleakage Transport Group Inventory:

Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:

Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Faulted S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Compartment Atmosphere Nuclide Inventory:

Time (h) = 2.0000 Ci kg Atoms Bq Rb-86 4.9339E-06 6.0638E-14 4.2462E+11 1.8256E+05 Sr-89 3.6199E-07 1.2460E-14 8.4310E+10 1.3394E+04

Numerical Applications Inc. Attachment 5 Page 121 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 I-131 1.2510E-03 1.0091E-11 4.6389E+13 4.6288E+07 I-132 6.1536E-04 5.9616E-14 2.7198E+11 2.2768E+07 I-133 1.4398E-03 1.2710E-12 5.7549E+12 5.3272E+07 I-134 3.4694E-04 1.3005E-14 5.8448E+10 1.2837E+07 I-135 1.1710E-03 3.3345E-13 1.4875E+12 4.3328E+07 Xe-133 5.0523E-04 2.6992E-12 1.2222E+13 1.8694E+07 Xe-135 5.5676E-03 2.1802E-12 9.7255E+12 2.0600E+08 Cs-134 5.1460E-04 3.9773E-10 1.7875E+15 1.9040E+07 Cs-136 1.4772E-04 2.0156E-12 8.9250E+12 5.4658E+06 Cs-137 2.7790E-04 3.1950E-09 1.4044E+16 1.0282E+07 I-130 3.5221E-05 1.8059E-14 8.3656E+10 1.3032E+06 Kr-83m 1.2357E-03 5.9894E-14 4.3457E+11 4.5723E+07 Xe-131m 2.1705E-06 2.5913E-14 1.1912E+11 8.0307E+04 Xe-133m 3.5970E-05 8.0164E-14 3.6298E+11 1.3309E+06 Xe-135m 1.1274E-02 1.2376E-13 5.5207E+11 4.1712E+08 Cs-138 2.5579E-04 6.0450E-15 2.6379E+10 9.4642E+06 Cs-134m 7.7066E-05 9.5564E-15 4.2948E+10 2.8514E+06 Rb-88 1.2683E-05 1.0566E-16 7.2306E+08 4.6928E+05 Rb-89 7.3196E-06 5.2662E-17 3.5633E+08 2.7082E+05 Ba-137m 3.0806E-04 5.7282E-16 2.5180E+09 1.1398E+07 Br-82 5.3461E-06 4.9380E-15 3.6265E+10 1.9781E+05 Br-83 5.3644E-05 3.3957E-15 2.4638E+10 1.9848E+06 Br-84 1.2246E-05 1.7397E-16 1.2473E+09 4.5311E+05 Control Room Transport Group Inventory:

Overlying Time (h) = 2.0000 Atmosphere Sump Pool Noble gases (atoms) 2.3416E+13 0.0000E+00 0.0000E+00 Elemental I (atoms) 5.2484E+13 0.0000E+00 0.0000E+00 Organic I (atoms) 1.6232E+12 0.0000E+00 0.0000E+00 Aerosols (kg) 3.5948E-09 0.0000E+00 0.0000E+00 Recirculating Filter Inventory Time (h) = 2.0000 Ci kg Atoms Bq Rb-86 2.0338E-04 2.4995E-12 1.7503E+13 7.5250E+06 Sr-89 1.4921E-05 5.1361E-13 3.4753E+12 5.5209E+05 I-131 5.1568E-02 4.1595E-10 1.9122E+15 1.9080E+09 I-132 2.5365E-02 2.4574E-12 1.1211E+13 9.3852E+08 I-133 5.9349E-02 5.2391E-11 2.3722E+14 2.1959E+09 I-134 1.4301E-02 5.3609E-13 2.4093E+12 5.2914E+08 I-135 4.8270E-02 1.3745E-11 6.1313E+13 1.7860E+09 Cs-134 2.1212E-02 1.6395E-08 7.3680E+16 7.8484E+08 Cs-136 6.0892E-03 8.3083E-11 3.6789E+14 2.2530E+08 Cs-137 1.1455E-02 1.3170E-07 5.7891E+17 4.2385E+08 I-130 1.4518E-03 7.4440E-13 3.4483E+12 5.3717E+07 Cs-138 1.0544E-02 2.4918E-13 1.0874E+12 3.9012E+08 Cs-134m 3.1767E-03 3.9392E-13 1.7703E+12 1.1754E+08 Rb-88 5.2281E-04 4.3553E-15 2.9805E+10 1.9344E+07 Rb-89 3.0172E-04 2.1707E-15 1.4688E+10 1.1163E+07 Ba-137m 1.2698E-02 2.3612E-14 1.0379E+11 4.6984E+08 Br-82 2.2037E-04 2.0355E-13 1.4949E+12 8.1536E+06 Br-83 2.2112E-03 1.3997E-13 1.0156E+12 8.1815E+07 Br-84 5.0479E-04 7.1713E-15 5.1412E+10 1.8677E+07 Deposition Recirculating Time (h) = 2.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 2.1634E+15 Organic I (atoms) 0.0000E+00 6.6910E+13 Aerosols (kg) 0.0000E+00 1.4818E-07 Control Room Unfiltered Makeup Transport Group Inventory:

Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Filter Pathway Nuclide Inventory for Control Room Filtered Makeup

Numerical Applications Inc. Attachment 5 Page 122 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Time (h) = 2.0000 Ci kg Atoms Bq Rb-86 2.9362E-04 3.6085E-12 2.5269E+13 1.0864E+07 Sr-89 2.1542E-05 7.4149E-13 5.0173E+12 7.9705E+05 I-131 7.4448E-02 6.0051E-10 2.7606E+15 2.7546E+09 I-132 3.6620E-02 3.5477E-12 1.6185E+13 1.3549E+09 I-133 8.5681E-02 7.5636E-11 3.4247E+14 3.1702E+09 I-134 2.0646E-02 7.7395E-13 3.4782E+12 7.6392E+08 I-135 6.9687E-02 1.9843E-11 8.8518E+13 2.5784E+09 Cs-134 3.0624E-02 2.3669E-08 1.0637E+17 1.1331E+09 Cs-136 8.7910E-03 1.1995E-10 5.3113E+14 3.2527E+08 Cs-137 1.6538E-02 1.9013E-07 8.3576E+17 6.1190E+08 I-130 2.0960E-03 1.0747E-12 4.9784E+12 7.7552E+07 Cs-138 1.5222E-02 3.5973E-13 1.5698E+12 5.6321E+08 Cs-134m 4.5862E-03 5.6870E-13 2.5558E+12 1.6969E+08 Rb-88 7.5477E-04 6.2877E-15 4.3029E+10 2.7927E+07 Rb-89 4.3558E-04 3.1339E-15 2.1205E+10 1.6117E+07 Ba-137m 1.8333E-02 3.4088E-14 1.4984E+11 6.7831E+08 Br-82 3.1814E-04 2.9386E-13 2.1581E+12 1.1771E+07 Br-83 3.1923E-03 2.0207E-13 1.4662E+12 1.1812E+08 Br-84 7.2876E-04 1.0353E-14 7.4224E+10 2.6964E+07 Control Room Filtered Makeup Transport Group Inventory:

Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 3.1233E+15 Organic I (atoms) 9.6597E+13 Aerosols (kg) 2.1393E-07 Control Room Unfiltered Inleakage Transport Group Inventory:

Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:

Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Total Filter Nuclide Inventory:

Time (h) = 2.0000 Ci kg Atoms Bq Rb-86 4.9700E-04 6.1080E-12 4.2771E+13 1.8389E+07 Sr-89 3.6463E-05 1.2551E-12 8.4926E+12 1.3491E+06 I-131 1.2602E-01 1.0165E-09 4.6727E+15 4.6626E+09 I-132 6.1985E-02 6.0051E-12 2.7397E+13 2.2935E+09 I-133 1.4503E-01 1.2803E-10 5.7969E+14 5.3661E+09 I-134 3.4948E-02 1.3100E-12 5.8875E+12 1.2931E+09 I-135 1.1796E-01 3.3588E-11 1.4983E+14 4.3644E+09 Cs-134 5.1835E-02 4.0064E-08 1.8005E+17 1.9179E+09 Cs-136 1.4880E-02 2.0303E-10 8.9902E+14 5.5057E+08 Cs-137 2.7993E-02 3.2183E-07 1.4147E+18 1.0357E+09 I-130 3.5478E-03 1.8191E-12 8.4267E+12 1.3127E+08 Cs-138 2.5766E-02 6.0891E-13 2.6572E+12 9.5333E+08 Cs-134m 7.7628E-03 9.6261E-13 4.3261E+12 2.8723E+08 Rb-88 1.2776E-03 1.0643E-14 7.2834E+10 4.7270E+07 Rb-89 7.3730E-04 5.3046E-15 3.5893E+10 2.7280E+07 Ba-137m 3.1031E-02 5.7700E-14 2.5363E+11 1.1482E+09 Br-82 5.3851E-04 4.9741E-13 3.6530E+12 1.9925E+07 Br-83 5.4036E-03 3.4205E-13 2.4817E+12 1.9993E+08 Br-84 1.2336E-03 1.7524E-14 1.2564E+11 4.5642E+07 Faulted S/G Transport Group Inventory:

Numerical Applications Inc. Attachment 5 Page 123 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Overlying Time (h) = 2.0000 Atmosphere Sump Pool Noble gases (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 2.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Faulted S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Compartment Atmosphere Nuclide Inventory:

Time (h) = 2.0000 Ci kg Atoms Bq Rb-86 6.5786E-01 8.0851E-09 5.6616E+16 2.4341E+10 Sr-89 4.8266E-02 1.6614E-09 1.1241E+16 1.7858E+09 I-131 1.6681E+02 1.3455E-06 6.1852E+18 6.1718E+12 I-132 8.2049E+01 7.9488E-09 3.6264E+16 3.0358E+12 I-133 1.9197E+02 1.6947E-07 7.6733E+17 7.1030E+12 I-134 4.6260E+01 1.7341E-09 7.7932E+15 1.7116E+12 I-135 1.5614E+02 4.4460E-08 1.9833E+17 5.7771E+12 Xe-133 2.1117E+00 1.1282E-08 5.1082E+16 7.8133E+10 Xe-135 2.3896E+01 9.3574E-09 4.1742E+16 8.8416E+11 Cs-134 6.8614E+01 5.3031E-05 2.3833E+20 2.5387E+12 Cs-136 1.9697E+01 2.6875E-07 1.1900E+18 7.2877E+11 Cs-137 3.7054E+01 4.2600E-04 1.8726E+21 1.3710E+12 I-130 4.6962E+00 2.4079E-09 1.1154E+16 1.7376E+11 Kr-83m 4.9829E+00 2.4151E-10 1.7523E+15 1.8437E+11 Xe-131m 8.9969E-03 1.0741E-10 4.9378E+14 3.3289E+08 Xe-133m 1.4997E-01 3.3423E-10 1.5134E+15 5.5489E+09 Xe-135m 2.5558E+01 2.8057E-10 1.2516E+15 9.4565E+11 Cs-138 3.4106E+01 8.0600E-10 3.5173E+15 1.2619E+12 Cs-134m 1.0276E+01 1.2742E-09 5.7264E+15 3.8020E+11 Rb-88 1.6911E+00 1.4088E-11 9.6409E+13 6.2571E+10 Rb-89 9.7595E-01 7.0216E-12 4.7512E+13 3.6110E+10 Ba-137m 4.1075E+01 7.6377E-11 3.3573E+14 1.5198E+12 Br-82 7.1282E-01 6.5841E-10 4.8354E+15 2.6374E+10 Br-83 7.1526E+00 4.5276E-10 3.2850E+15 2.6465E+11 Br-84 1.6328E+00 2.3197E-11 1.6630E+14 6.0415E+10 Intact S/G Transport Group Inventory:

Overlying Time (h) = 2.0000 Atmosphere Sump Pool Noble gases (atoms) 9.7835E+16 0.0000E+00 0.0000E+00 Elemental I (atoms) 6.9980E+18 0.0000E+00 0.0000E+00 Organic I (atoms) 2.1643E+17 0.0000E+00 0.0000E+00 Aerosols (kg) 4.7931E-04 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 2.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Intact S/G Tube Leakage Transport Group Inventory:

Pathway Time (h) = 2.0000 Filter

Numerical Applications Inc. Attachment 5 Page 124 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Detailed model information at time (H) = 8.0000 EAB Doses:

Time (h) = 8.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 2.0703E-01 1.2806E+02 3.1236E-01 6.7469E+00 Accumulated dose (rem) 3.8126E-01 1.7151E+02 5.9511E-01 9.1168E+00 LPZ Doses:

Time (h) = 8.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 1.1638E-02 7.1990E+00 1.7559E-02 3.7928E-01 Accumulated dose (rem) 3.3167E-02 1.2568E+01 5.2496E-02 6.7211E-01 Control Room Doses:

Time (h) = 8.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 1.4141E-03 1.0397E+01 8.0175E-02 5.3237E-01 Accumulated dose (rem) 1.2056E-02 7.6580E+01 6.8514E-01 3.8870E+00 PCS Compartment Atmosphere Nuclide Inventory:

Time (h) = 8.0000 Ci kg Atoms Bq Rb-86 9.4208E+02 1.1578E-05 8.1076E+19 3.4857E+13 Sr-89 6.9818E+01 2.4032E-06 1.6261E+19 2.5833E+12 I-131 2.3596E+05 1.9033E-03 8.7494E+21 8.7304E+15 I-132 1.9443E+04 1.8836E-06 8.5935E+18 7.1939E+14 I-133 2.2719E+05 2.0056E-04 9.0810E+20 8.4061E+15 I-134 5.8198E+02 2.1816E-08 9.8044E+16 2.1533E+13 I-135 1.2029E+05 3.4254E-05 1.5280E+20 4.4509E+15 Xe-133 1.0902E+04 5.8241E-05 2.6371E+20 4.0336E+14 Xe-135 8.2325E+04 3.2237E-05 1.4380E+20 3.0460E+15 Cs-134 9.9153E+04 7.6635E-02 3.4441E+23 3.6686E+15 Cs-136 2.8095E+04 3.8334E-04 1.6974E+21 1.0395E+15 Cs-137 5.3557E+04 6.1573E-01 2.7066E+24 1.9816E+15 I-130 4.8484E+03 2.4859E-06 1.1516E+19 1.7939E+14 Kr-83m 3.9513E+03 1.9151E-07 1.3895E+18 1.4620E+14 Xe-131m 5.1090E+01 6.0995E-07 2.8040E+18 1.8903E+12 Xe-133m 7.5495E+02 1.6825E-06 7.6182E+18 2.7933E+13 Xe-135m 1.9797E+04 2.1733E-07 9.6947E+17 7.3249E+14 Cs-138 2.1245E+01 5.0208E-10 2.1910E+15 7.8607E+11 Cs-134m 3.5397E+03 4.3894E-07 1.9726E+18 1.3097E+14 Rb-88 1.9948E-03 1.6618E-14 1.1373E+11 7.3809E+07 Rb-89 1.0465E-04 7.5295E-16 5.0948E+09 3.8722E+06 Ba-137m 5.9369E+04 1.1039E-07 4.8525E+17 2.1967E+15 Br-82 9.1579E+02 8.4589E-07 6.2123E+18 3.3884E+13 Br-83 1.8144E+03 1.1485E-07 8.3330E+17 6.7132E+13 Br-84 9.2266E-01 1.3108E-11 9.3972E+13 3.4138E+10 PCS Transport Group Inventory:

Overlying Time (h) = 8.0000 Atmosphere Sump Pool Noble gases (atoms) 4.2030E+20 0.0000E+00 0.0000E+00 Elemental I (atoms) 9.5425E+21 0.0000E+00 0.0000E+00 Organic I (atoms) 2.9513E+20 0.0000E+00 0.0000E+00 Aerosols (kg) 6.9276E-01 0.0000E+00 0.0000E+00 Deposition Recirculating

Numerical Applications Inc. Attachment 5 Page 125 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Time (h) = 8.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Faulted SG Tube Leakage Transport Group Inventory:

Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Tube Leakage Transport Group Inventory:

Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Environment Integral Nuclide Release:

Time (h) = 8.0000 Ci kg Atoms Bq Rb-86 2.6922E+00 3.3087E-08 2.3169E+17 9.9613E+10 Sr-89 1.9952E-01 6.8677E-09 4.6470E+16 7.3824E+09 I-131 6.7431E+02 5.4391E-06 2.5004E+19 2.4949E+13 I-132 5.5563E+01 5.3829E-09 2.4558E+16 2.0558E+12 I-133 6.4925E+02 5.7314E-07 2.5951E+18 2.4022E+13 I-134 1.6631E+00 6.2344E-11 2.8018E+14 6.1536E+10 I-135 3.4377E+02 9.7888E-08 4.3666E+17 1.2719E+13 Xe-133 3.1169E+01 1.6652E-07 7.5398E+17 1.1533E+12 Xe-135 2.3538E+02 9.2170E-08 4.1115E+17 8.7089E+12 Cs-134 2.8335E+02 2.1900E-04 9.8423E+20 1.0484E+13 Cs-136 8.0289E+01 1.0955E-06 4.8508E+18 2.9707E+12 Cs-137 1.5305E+02 1.7596E-03 7.7347E+21 5.6629E+12 I-130 1.3856E+01 7.1042E-09 3.2909E+16 5.1265E+11 Kr-83m 1.1297E+01 5.4754E-10 3.9728E+15 4.1799E+11 Xe-131m 1.4607E-01 1.7439E-09 8.0169E+15 5.4047E+09 Xe-133m 2.1585E+00 4.8105E-09 2.1781E+16 7.9864E+10 Xe-135m 5.6589E+01 6.2122E-10 2.7712E+15 2.0938E+12 Cs-138 6.0713E-02 1.4348E-12 6.2613E+12 2.2464E+09 Cs-134m 1.0116E+01 1.2544E-09 5.6373E+15 3.7428E+11 Rb-88 5.7008E-06 4.7491E-17 3.2500E+08 2.1093E+05 Ba-137m 1.6966E+02 3.1547E-10 1.3867E+15 6.2775E+12 Br-82 2.6171E+00 2.4173E-09 1.7753E+16 9.6833E+10 Br-83 5.1850E+00 3.2821E-10 2.3814E+15 1.9185E+11 Br-84 2.6367E-03 3.7458E-14 2.6855E+11 9.7559E+07 Environment Transport Group Inventory:

Present Release Integral Time (h) = 8.0000 Release Rate/s Release Noble gases (atoms) 3.0773E+15 4.2741E+13 1.2017E+18 Elemental I (atoms) 6.9808E+16 9.6955E+14 2.7270E+19 Organic I (atoms) 2.1590E+15 2.9986E+13 8.4340E+17 Aerosols (kg) 5.0678E-06 7.0387E-08 1.9797E-03 Faulted SG Tube Leakage Transport Group Inventory:

Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:

Pathway

Numerical Applications Inc. Attachment 5 Page 126 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Filter Pathway Nuclide Inventory for Control Room Filtered Makeup Time (h) = 8.0000 Ci kg Atoms Bq Rb-86 1.1541E-03 1.4184E-11 9.9321E+13 4.2702E+07 Sr-89 8.5531E-05 2.9440E-12 1.9921E+13 3.1646E+06 I-131 2.8906E-01 2.3316E-09 1.0718E+16 1.0695E+10 I-132 2.3819E-02 2.3075E-12 1.0527E+13 8.8129E+08 I-133 2.7832E-01 2.4569E-10 1.1125E+15 1.0298E+10 I-134 7.1295E-04 2.6726E-14 1.2011E+11 2.6379E+07 I-135 1.4737E-01 4.1962E-11 1.8719E+14 5.4525E+09 Cs-134 1.2147E-01 9.3881E-08 4.2192E+17 4.4943E+09 Cs-136 3.4418E-02 4.6961E-10 2.0794E+15 1.2735E+09 Cs-137 6.5610E-02 7.5429E-07 3.3157E+18 2.4276E+09 I-130 5.9395E-03 3.0454E-12 1.4107E+13 2.1976E+08 Cs-138 2.6026E-05 6.1507E-16 2.6841E+09 9.6297E+05 Cs-134m 4.3363E-03 5.3772E-13 2.4166E+12 1.6044E+08 Rb-88 2.4438E-09 2.0358E-20 1.3932E+05 9.0420E+01 Ba-137m 7.2730E-02 1.3524E-13 5.9446E+11 2.6910E+09 Br-82 1.1219E-03 1.0363E-12 7.6103E+12 4.1510E+07 Br-83 2.2227E-03 1.4070E-13 1.0208E+12 8.2239E+07 Br-84 1.1303E-06 1.6057E-17 1.1512E+08 4.1821E+04 Control Room Filtered Makeup Transport Group Inventory:

Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 1.1690E+16 Organic I (atoms) 3.6155E+14 Aerosols (kg) 8.4866E-07 Control Room Unfiltered Inleakage Transport Group Inventory:

Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:

Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Faulted S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00

Numerical Applications Inc. Attachment 5 Page 127 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Control Room Compartment Atmosphere Nuclide Inventory:

Time (h) = 8.0000 Ci kg Atoms Bq Rb-86 4.2449E-06 5.2170E-14 3.6532E+11 1.5706E+05 Sr-89 3.1459E-07 1.0829E-14 7.3271E+10 1.1640E+04 I-131 1.0632E-03 8.5759E-12 3.9424E+13 3.9338E+07 I-132 8.7608E-05 8.4873E-15 3.8721E+10 3.2415E+06 I-133 1.0237E-03 9.0368E-13 4.0918E+12 3.7877E+07 I-134 2.6223E-06 9.8300E-17 4.4177E+08 9.7026E+04 I-135 5.4203E-04 1.5434E-13 6.8850E+11 2.0055E+07 Xe-133 1.5297E-03 8.1721E-12 3.7003E+13 5.6598E+07 Xe-135 1.1152E-02 4.3669E-12 1.9480E+13 4.1262E+08 Cs-134 4.4677E-04 3.4531E-10 1.5519E+15 1.6530E+07 Cs-136 1.2659E-04 1.7273E-12 7.6484E+12 4.6840E+06 Cs-137 2.4132E-04 2.7744E-09 1.2195E+16 8.9289E+06 I-130 2.1846E-05 1.1201E-14 5.1889E+10 8.0831E+05 Kr-83m 6.8417E-04 3.3161E-14 2.4060E+11 2.5314E+07 Xe-131m 7.5222E-06 8.9806E-14 4.1284E+11 2.7832E+05 Xe-133m 1.0746E-04 2.3949E-13 1.0844E+12 3.9760E+06 Xe-135m 1.6331E-02 1.7928E-13 7.9972E+11 6.0423E+08 Cs-138 9.5728E-08 2.2623E-18 9.8723E+06 3.5419E+03 Cs-134m 1.5950E-05 1.9778E-15 8.8884E+09 5.9013E+05 Ba-137m 2.6751E-04 4.9741E-16 2.1865E+09 9.8979E+06 Br-82 4.1264E-06 3.8115E-15 2.7992E+10 1.5268E+05 Br-83 8.1753E-06 5.1750E-16 3.7548E+09 3.0249E+05 Br-84 4.1574E-09 5.9061E-20 4.2342E+05 1.5382E+02 Control Room Transport Group Inventory:

Overlying Time (h) = 8.0000 Atmosphere Sump Pool Noble gases (atoms) 5.9021E+13 0.0000E+00 0.0000E+00 Elemental I (atoms) 4.2997E+13 0.0000E+00 0.0000E+00 Organic I (atoms) 1.3298E+12 0.0000E+00 0.0000E+00 Aerosols (kg) 3.1215E-09 0.0000E+00 0.0000E+00 Recirculating Filter Inventory Time (h) = 8.0000 Ci kg Atoms Bq Rb-86 2.6021E-04 3.1980E-12 2.2394E+13 9.6279E+06 Sr-89 1.9285E-05 6.6379E-13 4.4915E+12 7.1353E+05 I-131 6.5174E-02 5.2571E-10 2.4167E+15 2.4114E+09 I-132 5.3704E-03 5.2028E-13 2.3736E+12 1.9870E+08 I-133 6.2753E-02 5.5396E-11 2.5083E+14 2.3218E+09 I-134 1.6075E-04 6.0258E-15 2.7081E+10 5.9477E+06 I-135 3.3226E-02 9.4612E-12 4.2205E+13 1.2294E+09 Cs-134 2.7387E-02 2.1167E-08 9.5129E+16 1.0133E+09 Cs-136 7.7602E-03 1.0588E-10 4.6885E+14 2.8713E+08 Cs-137 1.4793E-02 1.7007E-07 7.4758E+17 5.4734E+08 I-130 1.3392E-03 6.8664E-13 3.1808E+12 4.9550E+07 Cs-138 5.8681E-06 1.3868E-16 6.0518E+08 2.1712E+05 Cs-134m 9.7771E-04 1.2124E-13 5.4486E+11 3.6175E+07 Ba-137m 1.6398E-02 3.0492E-14 1.3403E+11 6.0674E+08 Br-82 2.5295E-04 2.3364E-13 1.7159E+12 9.3592E+06 Br-83 5.0115E-04 3.1723E-14 2.3017E+11 1.8543E+07 Br-84 2.5485E-07 3.6205E-18 2.5956E+07 9.4294E+03 Deposition Recirculating Time (h) = 8.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 2.6357E+15 Organic I (atoms) 0.0000E+00 8.1518E+13 Aerosols (kg) 0.0000E+00 1.9135E-07 Control Room Unfiltered Makeup Transport Group Inventory:

Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00

Numerical Applications Inc. Attachment 5 Page 128 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Filter Pathway Nuclide Inventory for Control Room Filtered Makeup Time (h) = 8.0000 Ci kg Atoms Bq Rb-86 1.1541E-03 1.4184E-11 9.9321E+13 4.2702E+07 Sr-89 8.5531E-05 2.9440E-12 1.9921E+13 3.1646E+06 I-131 2.8906E-01 2.3316E-09 1.0718E+16 1.0695E+10 I-132 2.3819E-02 2.3075E-12 1.0527E+13 8.8129E+08 I-133 2.7832E-01 2.4569E-10 1.1125E+15 1.0298E+10 I-134 7.1295E-04 2.6726E-14 1.2011E+11 2.6379E+07 I-135 1.4737E-01 4.1962E-11 1.8719E+14 5.4525E+09 Cs-134 1.2147E-01 9.3881E-08 4.2192E+17 4.4943E+09 Cs-136 3.4418E-02 4.6961E-10 2.0794E+15 1.2735E+09 Cs-137 6.5610E-02 7.5429E-07 3.3157E+18 2.4276E+09 I-130 5.9395E-03 3.0454E-12 1.4107E+13 2.1976E+08 Cs-138 2.6026E-05 6.1507E-16 2.6841E+09 9.6297E+05 Cs-134m 4.3363E-03 5.3772E-13 2.4166E+12 1.6044E+08 Rb-88 2.4438E-09 2.0358E-20 1.3932E+05 9.0420E+01 Ba-137m 7.2730E-02 1.3524E-13 5.9446E+11 2.6910E+09 Br-82 1.1219E-03 1.0363E-12 7.6103E+12 4.1510E+07 Br-83 2.2227E-03 1.4070E-13 1.0208E+12 8.2239E+07 Br-84 1.1303E-06 1.6057E-17 1.1512E+08 4.1821E+04 Control Room Filtered Makeup Transport Group Inventory:

Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 1.1690E+16 Organic I (atoms) 3.6155E+14 Aerosols (kg) 8.4866E-07 Control Room Unfiltered Inleakage Transport Group Inventory:

Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:

Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Total Filter Nuclide Inventory:

Time (h) = 8.0000 Ci kg Atoms Bq Rb-86 1.4143E-03 1.7382E-11 1.2172E+14 5.2329E+07 Sr-89 1.0482E-04 3.6078E-12 2.4412E+13 3.8782E+06 I-131 3.5423E-01 2.8573E-09 1.3135E+16 1.3107E+10 I-132 2.9189E-02 2.8278E-12 1.2901E+13 1.0800E+09 I-133 3.4107E-01 3.0108E-10 1.3633E+15 1.2620E+10 I-134 8.7370E-04 3.2751E-14 1.4719E+11 3.2327E+07 I-135 1.8059E-01 5.1423E-11 2.2939E+14 6.6819E+09 Cs-134 1.4885E-01 1.1505E-07 5.1704E+17 5.5076E+09 Cs-136 4.2178E-02 5.7549E-10 2.5483E+15 1.5606E+09 Cs-137 8.0403E-02 9.2436E-07 4.0632E+18 2.9749E+09 I-130 7.2787E-03 3.7320E-12 1.7288E+13 2.6931E+08 Cs-138 3.1894E-05 7.5375E-16 3.2893E+09 1.1801E+06 Cs-134m 5.3140E-03 6.5896E-13 2.9614E+12 1.9662E+08 Rb-88 2.9948E-09 2.4948E-20 1.7073E+05 1.1081E+02 Ba-137m 8.9128E-02 1.6573E-13 7.2849E+11 3.2978E+09 Br-82 1.3748E-03 1.2699E-12 9.3262E+12 5.0869E+07 Br-83 2.7238E-03 1.7242E-13 1.2510E+12 1.0078E+08 Br-84 1.3852E-06 1.9678E-17 1.4108E+08 5.1251E+04 Faulted S/G Transport Group Inventory:

Numerical Applications Inc. Attachment 5 Page 129 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Overlying Time (h) = 8.0000 Atmosphere Sump Pool Noble gases (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 8.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Faulted S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Compartment Atmosphere Nuclide Inventory:

Time (h) = 8.0000 Ci kg Atoms Bq Rb-86 2.5477E+00 3.1311E-08 2.1926E+17 9.4265E+10 Sr-89 1.8881E-01 6.4990E-09 4.3975E+16 6.9860E+09 I-131 6.3811E+02 5.1471E-06 2.3661E+19 2.3610E+13 I-132 5.2580E+01 5.0939E-09 2.3240E+16 1.9455E+12 I-133 6.1440E+02 5.4237E-07 2.4558E+18 2.2733E+13 I-134 1.5739E+00 5.8997E-11 2.6514E+14 5.8233E+10 I-135 3.2531E+02 9.2633E-08 4.1322E+17 1.2037E+13 Xe-133 2.9482E+01 1.5750E-07 7.1316E+17 1.0908E+12 Xe-135 2.2263E+02 8.7180E-08 3.8889E+17 8.2374E+12 Cs-134 2.6814E+02 2.0725E-04 9.3139E+20 9.9212E+12 Cs-136 7.5979E+01 1.0367E-06 4.5904E+18 2.8112E+12 Cs-137 1.4484E+02 1.6651E-03 7.3194E+21 5.3589E+12 I-130 1.3112E+01 6.7228E-09 3.1143E+16 4.8513E+11 Kr-83m 1.0685E+01 5.1791E-10 3.7577E+15 3.9536E+11 Xe-131m 1.3816E-01 1.6495E-09 7.5829E+15 5.1121E+09 Xe-133m 2.0416E+00 4.5500E-09 2.0602E+16 7.5540E+10 Xe-135m 5.3538E+01 5.8773E-10 2.6218E+15 1.9809E+12 Cs-138 5.7454E-02 1.3578E-12 5.9252E+12 2.1258E+09 Cs-134m 9.5726E+00 1.1870E-09 5.3346E+15 3.5419E+11 Rb-88 5.3947E-06 4.4942E-17 3.0755E+08 1.9960E+05 Rb-89 2.8302E-07 2.0362E-18 1.3778E+07 1.0472E+04 Ba-137m 1.6055E+02 2.9854E-10 1.3123E+15 5.9405E+12 Br-82 2.4766E+00 2.2876E-09 1.6800E+16 9.1634E+10 Br-83 4.9066E+00 3.1059E-10 2.2535E+15 1.8155E+11 Br-84 2.4952E-03 3.5447E-14 2.5413E+11 9.2321E+07 Intact S/G Transport Group Inventory:

Overlying Time (h) = 8.0000 Atmosphere Sump Pool Noble gases (atoms) 1.1366E+18 0.0000E+00 0.0000E+00 Elemental I (atoms) 2.5806E+19 0.0000E+00 0.0000E+00 Organic I (atoms) 7.9812E+17 0.0000E+00 0.0000E+00 Aerosols (kg) 1.8734E-03 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 8.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Intact S/G Tube Leakage Transport Group Inventory:

Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00

Numerical Applications Inc. Attachment 5 Page 130 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Detailed model information at time (H) = 12.0000 EAB Doses:

Time (h) = 12.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 9.3324E-02 4.0402E+01 1.4280E-01 2.1892E+00 Accumulated dose (rem) 4.7459E-01 2.1191E+02 7.3791E-01 1.1306E+01 LPZ Doses:

Time (h) = 12.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 3.5321E-03 1.5291E+00 5.4047E-03 8.2857E-02 Accumulated dose (rem) 3.6699E-02 1.4097E+01 5.7901E-02 7.5497E-01 Control Room Doses:

Time (h) = 12.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 6.7307E-04 2.8264E+00 3.8894E-02 1.4723E-01 Accumulated dose (rem) 1.2730E-02 7.9406E+01 7.2403E-01 4.0343E+00 PCS Compartment Atmosphere Nuclide Inventory:

Time (h) = 12.0000 Ci kg Atoms Bq Rb-86 9.3367E+02 1.1475E-05 8.0352E+19 3.4546E+13 Sr-89 6.9466E+01 2.3911E-06 1.6179E+19 2.5702E+12 I-131 2.3195E+05 1.8709E-03 8.6007E+21 8.5821E+15 I-132 5.8080E+03 5.6267E-07 2.5670E+18 2.1490E+14 I-133 1.9829E+05 1.7504E-04 7.9257E+20 7.3366E+15 I-134 2.4557E+01 9.2055E-10 4.1371E+15 9.0862E+11 I-135 7.8863E+04 2.2456E-05 1.0017E+20 2.9179E+15 Xe-133 1.5140E+04 8.0884E-05 3.6624E+20 5.6018E+14 Xe-135 8.6180E+04 3.3747E-05 1.5054E+20 3.1887E+15 Cs-134 9.8863E+04 7.6411E-02 3.4340E+23 3.6579E+15 Cs-136 2.7771E+04 3.7892E-04 1.6779E+21 1.0275E+15 Cs-137 5.3408E+04 6.1401E-01 2.6990E+24 1.9761E+15 I-130 3.8634E+03 1.9809E-06 9.1764E+18 1.4295E+14 Kr-83m 1.5921E+03 7.7167E-08 5.5989E+17 5.8908E+13 Xe-131m 7.5510E+01 9.0149E-07 4.1442E+18 2.7939E+12 Xe-133m 1.0303E+03 2.2963E-06 1.0397E+19 3.8123E+13 Xe-135m 1.2979E+04 1.4248E-07 6.3557E+17 4.8021E+14 Cs-138 1.2088E-01 2.8567E-12 1.2466E+13 4.4725E+09 Cs-134m 1.3569E+03 1.6826E-07 7.5618E+17 5.0206E+13 Rb-88 1.7373E-07 1.4473E-18 9.9042E+06 6.4280E+03 Ba-137m 5.9204E+04 1.1009E-07 4.8390E+17 2.1906E+15 Br-82 8.4427E+02 7.7983E-07 5.7271E+18 3.1238E+13 Br-83 5.6716E+02 3.5901E-08 2.6048E+17 2.0985E+13 Br-84 4.9194E-03 6.9887E-14 5.0103E+11 1.8202E+08 PCS Transport Group Inventory:

Overlying Time (h) = 12.0000 Atmosphere Sump Pool Noble gases (atoms) 5.3251E+20 0.0000E+00 0.0000E+00 Elemental I (atoms) 9.2259E+21 0.0000E+00 0.0000E+00 Organic I (atoms) 2.8534E+20 0.0000E+00 0.0000E+00 Aerosols (kg) 6.9082E-01 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 12.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00

Numerical Applications Inc. Attachment 5 Page 131 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Faulted SG Tube Leakage Transport Group Inventory:

Pathway Time (h) = 12.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Tube Leakage Transport Group Inventory:

Pathway Time (h) = 12.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Environment Integral Nuclide Release:

Time (h) = 12.0000 Ci kg Atoms Bq Rb-86 3.9723E+00 4.8820E-08 3.4186E+17 1.4698E+11 Sr-89 2.9554E-01 1.0173E-08 6.8834E+16 1.0935E+10 I-131 9.8682E+02 7.9599E-06 3.6592E+19 3.6512E+13 I-132 2.4710E+01 2.3939E-09 1.0922E+16 9.1428E+11 I-133 8.4361E+02 7.4471E-07 3.3720E+18 3.1214E+13 I-134 1.0448E-01 3.9165E-12 1.7601E+13 3.8657E+09 I-135 3.3552E+02 9.5539E-08 4.2619E+17 1.2414E+13 Xe-133 6.4439E+01 3.4426E-07 1.5588E+18 2.3842E+12 Xe-135 3.6680E+02 1.4363E-07 6.4073E+17 1.3572E+13 Cs-134 4.2061E+02 3.2509E-04 1.4610E+21 1.5563E+13 Cs-136 1.1815E+02 1.6121E-06 7.1385E+18 4.3717E+12 Cs-137 2.2722E+02 2.6123E-03 1.1483E+22 8.4073E+12 I-130 1.6437E+01 8.4278E-09 3.9041E+16 6.0817E+11 Kr-83m 6.7763E+00 3.2843E-10 2.3830E+15 2.5072E+11 Xe-131m 3.2138E-01 3.8369E-09 1.7638E+16 1.1891E+10 Xe-133m 4.3853E+00 9.7733E-09 4.4253E+16 1.6226E+11 Xe-135m 5.5228E+01 6.0629E-10 2.7046E+15 2.0434E+12 Cs-138 5.1428E-04 1.2154E-14 5.3038E+10 1.9028E+07 Cs-134m 5.7730E+00 7.1586E-10 3.2172E+15 2.1360E+11 Ba-137m 2.5188E+02 4.6836E-10 2.0588E+15 9.3197E+12 Br-82 3.5919E+00 3.3178E-09 2.4366E+16 1.3290E+11 Br-83 2.4130E+00 1.5274E-10 1.1082E+15 8.9280E+10 Br-84 2.0930E-05 2.9733E-16 2.1317E+09 7.7440E+05 Environment Transport Group Inventory:

Present Release Integral Time (h) = 12.0000 Release Rate/s Release Noble gases (atoms) 3.6947E+15 5.1315E+13 2.2665E+18 Elemental I (atoms) 6.3977E+16 8.8857E+14 3.9252E+19 Organic I (atoms) 1.9787E+15 2.7481E+13 1.2140E+18 Aerosols (kg) 4.7905E-06 6.6534E-08 2.9391E-03 Faulted SG Tube Leakage Transport Group Inventory:

Pathway Time (h) = 12.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:

Pathway Time (h) = 12.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00

Numerical Applications Inc. Attachment 5 Page 132 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Filter Pathway Nuclide Inventory for Control Room Filtered Makeup Time (h) = 12.0000 Ci kg Atoms Bq Rb-86 1.3680E-03 1.6812E-11 1.1773E+14 5.0615E+07 Sr-89 1.0178E-04 3.5033E-12 2.3705E+13 3.7658E+06 I-131 3.3984E-01 2.7412E-09 1.2601E+16 1.2574E+10 I-132 8.5096E-03 8.2440E-13 3.7611E+12 3.1486E+08 I-133 2.9052E-01 2.5646E-10 1.1612E+15 1.0749E+10 I-134 3.5980E-05 1.3487E-15 6.0614E+09 1.3313E+06 I-135 1.1555E-01 3.2902E-11 1.4677E+14 4.2752E+09 Cs-134 1.4485E-01 1.1195E-07 5.0314E+17 5.3594E+09 Cs-136 4.0689E-02 5.5517E-10 2.4583E+15 1.5055E+09 Cs-137 7.8251E-02 8.9962E-07 3.9545E+18 2.8953E+09 I-130 5.6605E-03 2.9023E-12 1.3445E+13 2.0944E+08 Cs-138 1.7711E-07 4.1855E-18 1.8265E+07 6.5529E+03 Cs-134m 1.9881E-03 2.4653E-13 1.1079E+12 7.3559E+07 Ba-137m 8.6743E-02 1.6129E-13 7.0899E+11 3.2095E+09 Br-82 1.2370E-03 1.1426E-12 8.3911E+12 4.5768E+07 Br-83 8.3097E-04 5.2601E-14 3.8165E+11 3.0746E+07 Br-84 7.2077E-09 1.0239E-19 7.3409E+05 2.6668E+02 Control Room Filtered Makeup Transport Group Inventory:

Pathway Time (h) = 12.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 1.3517E+16 Organic I (atoms) 4.1806E+14 Aerosols (kg) 1.0122E-06 Control Room Unfiltered Inleakage Transport Group Inventory:

Pathway Time (h) = 12.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:

Pathway Time (h) = 12.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 12.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Faulted S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 12.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Compartment Atmosphere Nuclide Inventory:

Time (h) = 12.0000 Ci kg Atoms Bq Rb-86 1.6351E-06 2.0096E-14 1.4072E+11 6.0499E+04

Numerical Applications Inc. Attachment 5 Page 133 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Sr-89 1.2165E-07 4.1874E-15 2.8334E+10 4.5012E+03 I-131 4.0620E-04 3.2765E-12 1.5062E+13 1.5030E+07 I-132 1.0171E-05 9.8540E-16 4.4956E+09 3.7634E+05 I-133 3.4726E-04 3.0654E-13 1.3880E+12 1.2848E+07 I-134 4.3007E-08 1.6121E-18 7.2452E+06 1.5912E+03 I-135 1.3811E-04 3.9327E-14 1.7543E+11 5.1101E+06 Xe-133 1.2178E-03 6.5058E-12 2.9458E+13 4.5057E+07 Xe-135 6.5946E-03 2.5823E-12 1.1519E+13 2.4400E+08 Cs-134 1.7314E-04 1.3382E-10 6.0139E+14 6.4061E+06 Cs-136 4.8635E-05 6.6359E-13 2.9384E+12 1.7995E+06 Cs-137 9.3532E-05 1.0753E-09 4.7267E+15 3.4607E+06 I-130 6.7659E-06 3.4691E-15 1.6070E+10 2.5034E+05 Kr-83m 1.9804E-04 9.5987E-15 6.9644E+10 7.3275E+06 Xe-131m 6.7362E-06 8.0422E-14 3.6970E+11 2.4924E+05 Xe-133m 8.5480E-05 1.9050E-13 8.6259E+11 3.1628E+06 Xe-135m 1.2347E-02 1.3554E-13 6.0462E+11 4.5683E+08 Cs-134m 2.3763E-06 2.9467E-16 1.3243E+09 8.7924E+04 Ba-137m 1.0368E-04 1.9279E-16 8.4745E+08 3.8363E+06 Br-82 1.4785E-06 1.3657E-15 1.0030E+10 5.4706E+04 Br-83 9.9325E-07 6.2873E-17 4.5618E+08 3.6750E+04 Control Room Transport Group Inventory:

Overlying Time (h) = 12.0000 Atmosphere Sump Pool Noble gases (atoms) 4.2884E+13 0.0000E+00 0.0000E+00 Elemental I (atoms) 1.6157E+13 0.0000E+00 0.0000E+00 Organic I (atoms) 4.9970E+11 0.0000E+00 0.0000E+00 Aerosols (kg) 1.2098E-09 0.0000E+00 0.0000E+00 Recirculating Filter Inventory Time (h) = 12.0000 Ci kg Atoms Bq Rb-86 2.7520E-04 3.3821E-12 2.3683E+13 1.0182E+07 Sr-89 2.0475E-05 7.0476E-13 4.7687E+12 7.5757E+05 I-131 6.8366E-02 5.5145E-10 2.5350E+15 2.5295E+09 I-132 1.7119E-03 1.6585E-13 7.5663E+11 6.3340E+07 I-133 5.8444E-02 5.1592E-11 2.3361E+14 2.1624E+09 I-134 7.2382E-06 2.7133E-16 1.2194E+09 2.6781E+05 I-135 2.3244E-02 6.6188E-12 2.9526E+13 8.6004E+08 Cs-134 2.9139E-02 2.2522E-08 1.0122E+17 1.0782E+09 Cs-136 8.1855E-03 1.1168E-10 4.9455E+14 3.0286E+08 Cs-137 1.5742E-02 1.8098E-07 7.9553E+17 5.8245E+08 I-130 1.1387E-03 5.8386E-13 2.7047E+12 4.2133E+07 Cs-138 3.5629E-08 8.4200E-19 3.6744E+06 1.3183E+03 Cs-134m 3.9994E-04 4.9594E-14 2.2288E+11 1.4798E+07 Ba-137m 1.7450E-02 3.2447E-14 1.4263E+11 6.4566E+08 Br-82 2.4884E-04 2.2985E-13 1.6880E+12 9.2073E+06 Br-83 1.6717E-04 1.0582E-14 7.6777E+10 6.1852E+06 Br-84 1.4500E-09 2.0599E-20 1.4768E+05 5.3649E+01 Deposition Recirculating Time (h) = 12.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 2.7193E+15 Organic I (atoms) 0.0000E+00 8.4102E+13 Aerosols (kg) 0.0000E+00 2.0362E-07 Control Room Unfiltered Makeup Transport Group Inventory:

Pathway Time (h) = 12.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Filter Pathway Nuclide Inventory for Control Room Filtered Makeup Time (h) = 12.0000 Ci kg Atoms Bq Rb-86 1.3680E-03 1.6812E-11 1.1773E+14 5.0615E+07 Sr-89 1.0178E-04 3.5033E-12 2.3705E+13 3.7658E+06 I-131 3.3984E-01 2.7412E-09 1.2601E+16 1.2574E+10

Numerical Applications Inc. Attachment 5 Page 134 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 I-132 8.5096E-03 8.2440E-13 3.7611E+12 3.1486E+08 I-133 2.9052E-01 2.5646E-10 1.1612E+15 1.0749E+10 I-134 3.5980E-05 1.3487E-15 6.0614E+09 1.3313E+06 I-135 1.1555E-01 3.2902E-11 1.4677E+14 4.2752E+09 Cs-134 1.4485E-01 1.1195E-07 5.0314E+17 5.3594E+09 Cs-136 4.0689E-02 5.5517E-10 2.4583E+15 1.5055E+09 Cs-137 7.8251E-02 8.9962E-07 3.9545E+18 2.8953E+09 I-130 5.6605E-03 2.9023E-12 1.3445E+13 2.0944E+08 Cs-138 1.7711E-07 4.1855E-18 1.8265E+07 6.5529E+03 Cs-134m 1.9881E-03 2.4653E-13 1.1079E+12 7.3559E+07 Ba-137m 8.6743E-02 1.6129E-13 7.0899E+11 3.2095E+09 Br-82 1.2370E-03 1.1426E-12 8.3911E+12 4.5768E+07 Br-83 8.3097E-04 5.2601E-14 3.8165E+11 3.0746E+07 Br-84 7.2077E-09 1.0239E-19 7.3409E+05 2.6668E+02 Control Room Filtered Makeup Transport Group Inventory:

Pathway Time (h) = 12.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 1.3517E+16 Organic I (atoms) 4.1806E+14 Aerosols (kg) 1.0122E-06 Control Room Unfiltered Inleakage Transport Group Inventory:

Pathway Time (h) = 12.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:

Pathway Time (h) = 12.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Total Filter Nuclide Inventory:

Time (h) = 12.0000 Ci kg Atoms Bq Rb-86 1.6432E-03 2.0194E-11 1.4141E+14 6.0797E+07 Sr-89 1.2225E-04 4.2080E-12 2.8473E+13 4.5233E+06 I-131 4.0820E-01 3.2926E-09 1.5136E+16 1.5104E+10 I-132 1.0221E-02 9.9025E-13 4.5177E+12 3.7820E+08 I-133 3.4897E-01 3.0805E-10 1.3948E+15 1.2912E+10 I-134 4.3218E-05 1.6201E-15 7.2808E+09 1.5991E+06 I-135 1.3879E-01 3.9520E-11 1.7629E+14 5.1352E+09 Cs-134 1.7399E-01 1.3448E-07 6.0435E+17 6.4376E+09 Cs-136 4.8875E-02 6.6686E-10 2.9529E+15 1.8084E+09 Cs-137 9.3992E-02 1.0806E-06 4.7500E+18 3.4777E+09 I-130 6.7992E-03 3.4862E-12 1.6149E+13 2.5157E+08 Cs-138 2.1273E-07 5.0275E-18 2.1939E+07 7.8712E+03 Cs-134m 2.3880E-03 2.9612E-13 1.3308E+12 8.8357E+07 Ba-137m 1.0419E-01 1.9374E-13 8.5162E+11 3.8551E+09 Br-82 1.4858E-03 1.3724E-12 1.0079E+13 5.4976E+07 Br-83 9.9814E-04 6.3182E-14 4.5843E+11 3.6931E+07 Br-84 8.6576E-09 1.2299E-19 8.8177E+05 3.2033E+02 Faulted S/G Transport Group Inventory:

Overlying Time (h) = 12.0000 Atmosphere Sump Pool Noble gases (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Deposition Recirculating

Numerical Applications Inc. Attachment 5 Page 135 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Time (h) = 12.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Faulted S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 12.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Compartment Atmosphere Nuclide Inventory:

Time (h) = 12.0000 Ci kg Atoms Bq Rb-86 3.8289E+00 4.7057E-08 3.2952E+17 1.4167E+11 Sr-89 2.8487E-01 9.8055E-09 6.6349E+16 1.0540E+10 I-131 9.5119E+02 7.6725E-06 3.5271E+19 3.5194E+13 I-132 2.3818E+01 2.3075E-09 1.0527E+16 8.8127E+11 I-133 8.1316E+02 7.1782E-07 3.2503E+18 3.0087E+13 I-134 1.0071E-01 3.7751E-12 1.6966E+13 3.7262E+09 I-135 3.2341E+02 9.2090E-08 4.1080E+17 1.1966E+13 Xe-133 6.2088E+01 3.3170E-07 1.5019E+18 2.2973E+12 Xe-135 3.5342E+02 1.3839E-07 6.1735E+17 1.3076E+13 Cs-134 4.0543E+02 3.1336E-04 1.4083E+21 1.5001E+13 Cs-136 1.1389E+02 1.5539E-06 6.8808E+18 4.2138E+12 Cs-137 2.1902E+02 2.5180E-03 1.1068E+22 8.1038E+12 I-130 1.5844E+01 8.1235E-09 3.7631E+16 5.8621E+11 Kr-83m 6.5291E+00 3.1645E-10 2.2961E+15 2.4158E+11 Xe-131m 3.0966E-01 3.6969E-09 1.6995E+16 1.1457E+10 Xe-133m 4.2254E+00 9.4168E-09 4.2638E+16 1.5634E+11 Xe-135m 5.3224E+01 5.8429E-10 2.6064E+15 1.9693E+12 Cs-138 4.9571E-04 1.1715E-14 5.1123E+10 1.8341E+07 Cs-134m 5.5646E+00 6.9002E-10 3.1010E+15 2.0589E+11 Ba-137m 2.4279E+02 4.5145E-10 1.9844E+15 8.9832E+12 Br-82 3.4623E+00 3.1980E-09 2.3486E+16 1.2810E+11 Br-83 2.3259E+00 1.4723E-10 1.0682E+15 8.6057E+10 Br-84 2.0174E-05 2.8660E-16 2.0547E+09 7.4644E+05 Intact S/G Transport Group Inventory:

Overlying Time (h) = 12.0000 Atmosphere Sump Pool Noble gases (atoms) 2.1838E+18 0.0000E+00 0.0000E+00 Elemental I (atoms) 3.7834E+19 0.0000E+00 0.0000E+00 Organic I (atoms) 1.1701E+18 0.0000E+00 0.0000E+00 Aerosols (kg) 2.8330E-03 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 12.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Intact S/G Tube Leakage Transport Group Inventory:

Pathway Time (h) = 12.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 12.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00

Numerical Applications Inc. Attachment 5 Page 136 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Detailed model information at time (H) = 24.0000 EAB Doses:

Time (h) = 24.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 9.6956E-06 2.5222E-05 1.6189E-05 1.1013E-05 Accumulated dose (rem) 4.7460E-01 2.1191E+02 7.3792E-01 1.1306E+01 LPZ Doses:

Time (h) = 24.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 3.6696E-07 9.5461E-07 6.1271E-07 4.1681E-07 Accumulated dose (rem) 3.6700E-02 1.4097E+01 5.7902E-02 7.5497E-01 Control Room Doses:

Time (h) = 24.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 7.9102E-04 1.3553E-01 4.4712E-02 7.8691E-03 Accumulated dose (rem) 1.3521E-02 7.9542E+01 7.6875E-01 4.0421E+00 PCS Compartment Atmosphere Nuclide Inventory:

Time (h) = 24.0000 Ci kg Atoms Bq Rb-86 9.1649E+02 1.1264E-05 7.8873E+19 3.3910E+13 Sr-89 6.8991E+01 2.3747E-06 1.6068E+19 2.5527E+12 I-131 2.2216E+05 1.7920E-03 8.2379E+21 8.2200E+15 I-132 1.5611E+02 1.5124E-08 6.8999E+16 5.7761E+12 I-133 1.3293E+05 1.1735E-04 5.3133E+20 4.9184E+15 I-134 1.8604E-03 6.9740E-14 3.1342E+11 6.8837E+07 I-135 2.2406E+04 6.3802E-06 2.8461E+19 8.2904E+14 Xe-133 2.4383E+04 1.3026E-04 5.8982E+20 9.0217E+14 Xe-135 5.9151E+04 2.3163E-05 1.0333E+20 2.1886E+15 Cs-134 9.8818E+04 7.6376E-02 3.4324E+23 3.6563E+15 Cs-136 2.7046E+04 3.6903E-04 1.6341E+21 1.0007E+15 Cs-137 5.3406E+04 6.1399E-01 2.6989E+24 1.9760E+15 I-130 1.9711E+03 1.0107E-06 4.6818E+18 7.2931E+13 Kr-83m 6.5943E+01 3.1961E-09 2.3190E+16 2.4399E+12 Xe-131m 1.4567E+02 1.7391E-06 7.9947E+18 5.3897E+12 Xe-133m 1.5702E+03 3.4993E-06 1.5845E+19 5.8096E+13 Xe-135m 3.6875E+03 4.0481E-08 1.8058E+17 1.3644E+14 Cs-138 2.2452E-08 5.3059E-19 2.3154E+06 8.3071E+02 Cs-134m 7.7074E+01 9.5574E-09 4.2952E+16 2.8517E+12 Ba-137m 5.9202E+04 1.1008E-07 4.8389E+17 2.1905E+15 Br-82 6.6703E+02 6.1612E-07 4.5248E+18 2.4680E+13 Br-83 1.7469E+01 1.1058E-09 8.0229E+15 6.4634E+11 PCS Transport Group Inventory:

Overlying Time (h) = 24.0000 Atmosphere Sump Pool Noble gases (atoms) 7.1719E+20 0.0000E+00 0.0000E+00 Elemental I (atoms) 8.5427E+21 0.0000E+00 0.0000E+00 Organic I (atoms) 2.6421E+20 0.0000E+00 0.0000E+00 Aerosols (kg) 6.9075E-01 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 24.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Faulted SG Tube Leakage Transport Group Inventory:

Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00

Numerical Applications Inc. Attachment 5 Page 137 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Intact S/G Tube Leakage Transport Group Inventory:

Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Environment Integral Nuclide Release:

Time (h) = 24.0000 Ci kg Atoms Bq Xe-133 1.0378E+02 5.5443E-07 2.5104E+18 3.8398E+12 Xe-135 2.5176E+02 9.8586E-08 4.3978E+17 9.3152E+12 Kr-83m 2.8066E-01 1.3603E-11 9.8700E+13 1.0385E+10 Xe-131m 6.2000E-01 7.4019E-09 3.4027E+16 2.2940E+10 Xe-133m 6.6830E+00 1.4894E-08 6.7439E+16 2.4727E+11 Xe-135m 1.5691E+01 1.7226E-10 7.6842E+14 5.8058E+11 Environment Transport Group Inventory:

Present Release Integral Time (h) = 24.0000 Release Rate/s Release Noble gases (atoms) 7.4978E+11 1.0414E+10 3.0525E+18 Elemental I (atoms) 1.9925E-13 2.7674E-15 3.6345E+19 Organic I (atoms) 6.1625E-15 8.5590E-17 1.1241E+18 Aerosols (kg) 1.6111E-35 2.2377E-37 2.9388E-03 Faulted SG Tube Leakage Transport Group Inventory:

Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:

Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Filter Pathway Nuclide Inventory for Control Room Filtered Makeup Time (h) = 24.0000 Ci kg Atoms Bq Rb-86 1.3428E-03 1.6503E-11 1.1556E+14 4.9684E+07 Sr-89 1.0108E-04 3.4793E-12 2.3543E+13 3.7400E+06 I-131 3.2550E-01 2.6255E-09 1.2070E+16 1.2043E+10 I-132 2.2873E-04 2.2159E-14 1.0109E+11 8.4629E+06 I-133 1.9476E-01 1.7193E-10 7.7848E+14 7.2062E+09 I-134 2.7258E-09 1.0218E-19 4.5921E+05 1.0086E+02 I-135 3.2829E-02 9.3480E-12 4.1700E+13 1.2147E+09 Cs-134 1.4478E-01 1.1190E-07 5.0291E+17 5.3570E+09 Cs-136 3.9627E-02 5.4068E-10 2.3941E+15 1.4662E+09 Cs-137 7.8248E-02 8.9959E-07 3.9544E+18 2.8952E+09 I-130 2.8880E-03 1.4808E-12 6.8595E+12 1.0686E+08 Cs-134m 1.1293E-04 1.4003E-14 6.2932E+10 4.1782E+06 Ba-137m 8.6740E-02 1.6129E-13 7.0897E+11 3.2094E+09 Br-82 9.7730E-04 9.0271E-13 6.6295E+12 3.6160E+07 Br-83 2.5594E-05 1.6201E-15 1.1755E+10 9.4698E+05 Control Room Filtered Makeup Transport Group Inventory:

Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 1.2516E+16 Organic I (atoms) 3.8710E+14

Numerical Applications Inc. Attachment 5 Page 138 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Aerosols (kg) 1.0121E-06 Control Room Unfiltered Inleakage Transport Group Inventory:

Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:

Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Faulted S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Compartment Atmosphere Nuclide Inventory:

Time (h) = 24.0000 Ci kg Atoms Bq Xe-133 5.4543E-04 2.9139E-12 1.3194E+13 2.0181E+07 Xe-135 1.2178E-03 4.7688E-13 2.1273E+12 4.5059E+07 Kr-83m 4.8549E-06 2.3531E-16 1.7073E+09 1.7963E+05 Xe-131m 4.5405E-06 5.4208E-14 2.4920E+11 1.6800E+05 Xe-133m 3.8919E-05 8.6736E-14 3.9273E+11 1.4400E+06 Xe-135m 3.4815E-03 3.8220E-14 1.7049E+11 1.2882E+08 Control Room Transport Group Inventory:

Overlying Time (h) = 24.0000 Atmosphere Sump Pool Noble gases (atoms) 1.6135E+13 0.0000E+00 0.0000E+00 Elemental I (atoms) 3.9955E-12 0.0000E+00 0.0000E+00 Organic I (atoms) 1.2357E-13 0.0000E+00 0.0000E+00 Aerosols (kg) 3.2307E-34 0.0000E+00 0.0000E+00 Recirculating Filter Inventory Time (h) = 24.0000 Ci kg Atoms Bq Rb-86 2.7093E-04 3.3297E-12 2.3316E+13 1.0024E+07 Sr-89 2.0395E-05 7.0200E-13 4.7500E+12 7.5460E+05 I-131 6.5674E-02 5.2974E-10 2.4352E+15 2.4299E+09 I-132 4.6149E-05 4.4709E-15 2.0397E+10 1.7075E+06 I-133 3.9296E-02 3.4689E-11 1.5707E+14 1.4540E+09 I-135 6.6236E-03 1.8861E-12 8.4135E+12 2.4508E+08 Cs-134 2.9212E-02 2.2578E-08 1.0147E+17 1.0808E+09 Cs-136 7.9953E-03 1.0909E-10 4.8305E+14 2.9583E+08 Cs-137 1.5788E-02 1.8151E-07 7.9785E+17 5.8414E+08 I-130 5.8269E-04 2.9876E-13 1.3840E+12 2.1560E+07 Cs-134m 2.2784E-05 2.8253E-15 1.2697E+10 8.4302E+05 Ba-137m 1.7501E-02 3.2542E-14 1.4304E+11 6.4754E+08 Br-82 1.9718E-04 1.8213E-13 1.3376E+12 7.2958E+06

Numerical Applications Inc. Attachment 5 Page 139 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Br-83 5.1640E-06 3.2688E-16 2.3717E+09 1.9107E+05 Deposition Recirculating Time (h) = 24.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 2.5254E+15 Organic I (atoms) 0.0000E+00 7.8104E+13 Aerosols (kg) 0.0000E+00 2.0420E-07 Control Room Unfiltered Makeup Transport Group Inventory:

Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Filter Pathway Nuclide Inventory for Control Room Filtered Makeup Time (h) = 24.0000 Ci kg Atoms Bq Rb-86 1.3428E-03 1.6503E-11 1.1556E+14 4.9684E+07 Sr-89 1.0108E-04 3.4793E-12 2.3543E+13 3.7400E+06 I-131 3.2550E-01 2.6255E-09 1.2070E+16 1.2043E+10 I-132 2.2873E-04 2.2159E-14 1.0109E+11 8.4629E+06 I-133 1.9476E-01 1.7193E-10 7.7848E+14 7.2062E+09 I-134 2.7258E-09 1.0218E-19 4.5921E+05 1.0086E+02 I-135 3.2829E-02 9.3480E-12 4.1700E+13 1.2147E+09 Cs-134 1.4478E-01 1.1190E-07 5.0291E+17 5.3570E+09 Cs-136 3.9627E-02 5.4068E-10 2.3941E+15 1.4662E+09 Cs-137 7.8248E-02 8.9959E-07 3.9544E+18 2.8952E+09 I-130 2.8880E-03 1.4808E-12 6.8595E+12 1.0686E+08 Cs-134m 1.1293E-04 1.4003E-14 6.2932E+10 4.1782E+06 Ba-137m 8.6740E-02 1.6129E-13 7.0897E+11 3.2094E+09 Br-82 9.7730E-04 9.0271E-13 6.6295E+12 3.6160E+07 Br-83 2.5594E-05 1.6201E-15 1.1755E+10 9.4698E+05 Control Room Filtered Makeup Transport Group Inventory:

Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 1.2516E+16 Organic I (atoms) 3.8710E+14 Aerosols (kg) 1.0121E-06 Control Room Unfiltered Inleakage Transport Group Inventory:

Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:

Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Total Filter Nuclide Inventory:

Time (h) = 24.0000 Ci kg Atoms Bq Rb-86 1.6137E-03 1.9833E-11 1.3888E+14 5.9708E+07 Sr-89 1.2148E-04 4.1813E-12 2.8293E+13 4.4946E+06 I-131 3.9117E-01 3.1553E-09 1.4505E+16 1.4473E+10 I-132 2.7488E-04 2.6630E-14 1.2149E+11 1.0170E+07 I-133 2.3406E-01 2.0662E-10 9.3555E+14 8.6602E+09 I-134 3.2758E-09 1.2280E-19 5.5186E+05 1.2121E+02

Numerical Applications Inc. Attachment 5 Page 140 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 I-135 3.9452E-02 1.1234E-11 5.0113E+13 1.4597E+09 Cs-134 1.7399E-01 1.3448E-07 6.0437E+17 6.4378E+09 Cs-136 4.7622E-02 6.4977E-10 2.8772E+15 1.7620E+09 Cs-137 9.4036E-02 1.0811E-06 4.7522E+18 3.4793E+09 I-130 3.4707E-03 1.7795E-12 8.2435E+12 1.2841E+08 Cs-134m 1.3571E-04 1.6828E-14 7.5629E+10 5.0213E+06 Ba-137m 1.0424E-01 1.9383E-13 8.5202E+11 3.8569E+09 Br-82 1.1745E-03 1.0848E-12 7.9671E+12 4.3456E+07 Br-83 3.0758E-05 1.9470E-15 1.4127E+10 1.1380E+06 Faulted S/G Transport Group Inventory:

Overlying Time (h) = 24.0000 Atmosphere Sump Pool Noble gases (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 24.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Faulted S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Compartment Atmosphere Nuclide Inventory:

Time (h) = 24.0000 Ci kg Atoms Bq Rb-86 3.7585E+00 4.6191E-08 3.2345E+17 1.3906E+11 Sr-89 2.8292E-01 9.7385E-09 6.5895E+16 1.0468E+10 I-131 9.1106E+02 7.3488E-06 3.3783E+19 3.3709E+13 I-132 6.4020E-01 6.2022E-11 2.8296E+14 2.3687E+10 I-133 5.4513E+02 4.8122E-07 2.1789E+18 2.0170E+13 I-134 7.6295E-06 2.8600E-16 1.2853E+09 2.8229E+05 I-135 9.1886E+01 2.6165E-08 1.1672E+17 3.3998E+12 Xe-133 9.9992E+01 5.3420E-07 2.4188E+18 3.6997E+12 Xe-135 2.4257E+02 9.4988E-08 4.2373E+17 8.9752E+12 Cs-134 4.0524E+02 3.1321E-04 1.4076E+21 1.4994E+13 Cs-136 1.1091E+02 1.5133E-06 6.7011E+18 4.1038E+12 Cs-137 2.1901E+02 2.5179E-03 1.1068E+22 8.1035E+12 I-130 8.0833E+00 4.1446E-09 1.9199E+16 2.9908E+11 Kr-83m 2.7042E-01 1.3107E-11 9.5099E+13 1.0006E+10 Xe-131m 5.9737E-01 7.1318E-09 3.2785E+16 2.2103E+10 Xe-133m 6.4391E+00 1.4350E-08 6.4977E+16 2.3825E+11 Xe-135m 1.5122E+01 1.6601E-10 7.4053E+14 5.5951E+11 Cs-134m 3.1607E-01 3.9194E-11 1.7614E+14 1.1695E+10 Ba-137m 2.4278E+02 4.5144E-10 1.9844E+15 8.9830E+12 Br-82 2.7354E+00 2.5266E-09 1.8556E+16 1.0121E+11 Br-83 7.1637E-02 4.5346E-12 3.2901E+13 2.6506E+09 Intact S/G Transport Group Inventory:

Overlying Time (h) = 24.0000 Atmosphere Sump Pool Noble gases (atoms) 2.9411E+18 0.0000E+00 0.0000E+00 Elemental I (atoms) 3.5033E+19 0.0000E+00 0.0000E+00 Organic I (atoms) 1.0835E+18 0.0000E+00 0.0000E+00 Aerosols (kg) 2.8327E-03 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 24.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00

Numerical Applications Inc. Attachment 5 Page 141 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Intact S/G Tube Leakage Transport Group Inventory:

Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Detailed model information at time (H) = 96.0000 EAB Doses:

Time (h) = 96.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 3.8933E-06 7.9011E-30 6.6479E-06 3.8933E-06 Accumulated dose (rem) 4.7460E-01 2.1191E+02 7.3793E-01 1.1306E+01 LPZ Doses:

Time (h) = 96.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 6.2625E-08 1.2709E-31 1.0693E-07 6.2625E-08 Accumulated dose (rem) 3.6700E-02 1.4097E+01 5.7902E-02 7.5497E-01 Control Room Doses:

Time (h) = 96.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 1.9058E-04 1.9936E-26 1.1017E-02 1.9058E-04 Accumulated dose (rem) 1.3711E-02 7.9542E+01 7.7976E-01 4.0423E+00 PCS Compartment Atmosphere Nuclide Inventory:

Time (h) = 96.0000 Ci kg Atoms Bq Rb-86 8.1985E+02 1.0076E-05 7.0556E+19 3.0334E+13 Sr-89 6.6207E+01 2.2789E-06 1.5420E+19 2.4497E+12 I-131 1.7153E+05 1.3836E-03 6.3605E+21 6.3467E+15 I-132 5.8869E-08 5.7032E-18 2.6019E+07 2.1782E+03 I-133 1.2067E+04 1.0652E-05 4.8232E+19 4.4648E+14 I-135 1.1786E+01 3.3561E-09 1.4971E+16 4.3609E+11 Xe-133 3.1819E+04 1.6999E-04 7.6970E+20 1.1773E+15 Xe-135 4.6066E+02 1.8039E-07 8.0469E+17 1.7045E+13 Cs-134 9.8545E+04 7.6166E-02 3.4230E+23 3.6462E+15 Cs-136 2.3076E+04 3.1486E-04 1.3942E+21 8.5383E+14 Cs-137 5.3396E+04 6.1388E-01 2.6984E+24 1.9757E+15 I-130 3.4765E+01 1.7825E-08 8.2573E+16 1.2863E+12 Kr-83m 6.3876E-08 3.0960E-18 2.2463E+07 2.3634E+03 Xe-131m 4.6939E+02 5.6039E-06 2.5761E+19 1.7367E+13 Xe-133m 1.3551E+03 3.0200E-06 1.3674E+19 5.0138E+13 Xe-135m 1.9397E+00 2.1294E-11 9.4988E+13 7.1769E+10 Cs-134m 2.5886E-06 3.2099E-16 1.4426E+09 9.5777E+04 Ba-137m 5.9191E+04 1.1006E-07 4.8380E+17 2.1901E+15 Br-82 1.6224E+02 1.4985E-07 1.1005E+18 6.0028E+12 Br-83 1.4913E-08 9.4401E-19 6.8493E+06 5.5179E+02 PCS Transport Group Inventory:

Overlying Time (h) = 96.0000 Atmosphere Sump Pool Noble gases (atoms) 8.0994E+20 0.0000E+00 0.0000E+00 Elemental I (atoms) 6.2176E+21 0.0000E+00 0.0000E+00 Organic I (atoms) 1.9230E+20 0.0000E+00 0.0000E+00 Aerosols (kg) 6.9037E-01 0.0000E+00 0.0000E+00

Numerical Applications Inc. Attachment 5 Page 142 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Deposition Recirculating Time (h) = 96.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Faulted SG Tube Leakage Transport Group Inventory:

Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Tube Leakage Transport Group Inventory:

Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Environment Integral Nuclide Release:

Time (h) = 96.0000 Ci kg Atoms Bq Xe-133 1.3543E+02 7.2352E-07 3.2761E+18 5.0109E+12 Xe-135 1.9607E+00 7.6778E-10 3.4250E+15 7.2546E+10 Xe-131m 1.9978E+00 2.3852E-08 1.0965E+17 7.3920E+10 Xe-133m 5.7676E+00 1.2854E-08 5.8201E+16 2.1340E+11 Xe-135m 8.2540E-03 9.0612E-14 4.0421E+11 3.0540E+08 Environment Transport Group Inventory:

Present Release Integral Time (h) = 96.0000 Release Rate/s Release Noble gases (atoms) 6.6303E+10 9.2088E+08 3.4473E+18 Elemental I (atoms) 0.0000E+00 0.0000E+00 2.6453E+19 Organic I (atoms) 0.0000E+00 0.0000E+00 8.1813E+17 Aerosols (kg) 0.0000E+00 0.0000E+00 2.9372E-03 Faulted SG Tube Leakage Transport Group Inventory:

Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:

Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Filter Pathway Nuclide Inventory for Control Room Filtered Makeup Time (h) = 96.0000 Ci kg Atoms Bq Rb-86 1.2012E-03 1.4763E-11 1.0338E+14 4.4444E+07 Sr-89 9.7004E-05 3.3390E-12 2.2593E+13 3.5891E+06 I-131 2.5132E-01 2.0272E-09 9.3191E+15 9.2988E+09 I-133 1.7680E-02 1.5607E-11 7.0668E+13 6.5416E+08 I-135 1.7269E-05 4.9172E-15 2.1935E+10 6.3894E+05 Cs-134 1.4438E-01 1.1159E-07 5.0152E+17 5.3422E+09 Cs-136 3.3811E-02 4.6132E-10 2.0427E+15 1.2510E+09 Cs-137 7.8233E-02 8.9942E-07 3.9536E+18 2.8946E+09

Numerical Applications Inc. Attachment 5 Page 143 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 I-130 5.0936E-05 2.6116E-14 1.2098E+11 1.8846E+06 Ba-137m 8.6724E-02 1.6126E-13 7.0884E+11 3.2088E+09 Br-82 2.3770E-04 2.1956E-13 1.6124E+12 8.7949E+06 Control Room Filtered Makeup Transport Group Inventory:

Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 9.1097E+15 Organic I (atoms) 2.8174E+14 Aerosols (kg) 1.0115E-06 Control Room Unfiltered Inleakage Transport Group Inventory:

Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:

Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Faulted S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Compartment Atmosphere Nuclide Inventory:

Time (h) = 96.0000 Ci kg Atoms Bq Xe-133 4.9512E-05 2.6451E-13 1.1977E+12 1.8320E+06 Xe-135 6.4060E-07 2.5085E-16 1.1190E+09 2.3702E+04 Xe-131m 3.5057E-06 4.1854E-14 1.9240E+11 1.2971E+05 Xe-133m 3.5329E-06 7.8735E-15 3.5651E+10 1.3072E+05 Xe-135m 1.8314E-06 2.0104E-17 8.9683E+07 6.7760E+04 Control Room Transport Group Inventory:

Overlying Time (h) = 96.0000 Atmosphere Sump Pool Noble gases (atoms) 1.4270E+12 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Recirculating Filter Inventory Time (h) = 96.0000 Ci kg Atoms Bq Rb-86 2.4236E-04 2.9786E-12 2.0857E+13 8.9673E+06 Sr-89 1.9572E-05 6.7368E-13 4.5584E+12 7.2416E+05 I-131 5.0707E-02 4.0901E-10 1.8803E+15 1.8762E+09

Numerical Applications Inc. Attachment 5 Page 144 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 I-133 3.5672E-03 3.1490E-12 1.4258E+13 1.3199E+08 I-135 3.4842E-06 9.9212E-16 4.4257E+09 1.2892E+05 Cs-134 2.9131E-02 2.2516E-08 1.0119E+17 1.0779E+09 Cs-136 6.8217E-03 9.3078E-11 4.1215E+14 2.5240E+08 Cs-137 1.5785E-02 1.8147E-07 7.9770E+17 5.8403E+08 I-130 1.0277E-05 5.2693E-15 2.4410E+10 3.8025E+05 Ba-137m 1.7498E-02 3.2536E-14 1.4302E+11 6.4742E+08 Br-82 4.7960E-05 4.4299E-14 3.2533E+11 1.7745E+06 Deposition Recirculating Time (h) = 96.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 1.8380E+15 Organic I (atoms) 0.0000E+00 5.6846E+13 Aerosols (kg) 0.0000E+00 2.0408E-07 Control Room Unfiltered Makeup Transport Group Inventory:

Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Filter Pathway Nuclide Inventory for Control Room Filtered Makeup Time (h) = 96.0000 Ci kg Atoms Bq Rb-86 1.2012E-03 1.4763E-11 1.0338E+14 4.4444E+07 Sr-89 9.7004E-05 3.3390E-12 2.2593E+13 3.5891E+06 I-131 2.5132E-01 2.0272E-09 9.3191E+15 9.2988E+09 I-133 1.7680E-02 1.5607E-11 7.0668E+13 6.5416E+08 I-135 1.7269E-05 4.9172E-15 2.1935E+10 6.3894E+05 Cs-134 1.4438E-01 1.1159E-07 5.0152E+17 5.3422E+09 Cs-136 3.3811E-02 4.6132E-10 2.0427E+15 1.2510E+09 Cs-137 7.8233E-02 8.9942E-07 3.9536E+18 2.8946E+09 I-130 5.0936E-05 2.6116E-14 1.2098E+11 1.8846E+06 Ba-137m 8.6724E-02 1.6126E-13 7.0884E+11 3.2088E+09 Br-82 2.3770E-04 2.1956E-13 1.6124E+12 8.7949E+06 Control Room Filtered Makeup Transport Group Inventory:

Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 9.1097E+15 Organic I (atoms) 2.8174E+14 Aerosols (kg) 1.0115E-06 Control Room Unfiltered Inleakage Transport Group Inventory:

Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:

Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Total Filter Nuclide Inventory:

Time (h) = 96.0000 Ci kg Atoms Bq Rb-86 1.4436E-03 1.7741E-11 1.2423E+14 5.3412E+07 Sr-89 1.1658E-04 4.0126E-12 2.7151E+13 4.3133E+06 I-131 3.0203E-01 2.4362E-09 1.1199E+16 1.1175E+10

Numerical Applications Inc. Attachment 5 Page 145 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 I-133 2.1247E-02 1.8756E-11 8.4926E+13 7.8614E+08 I-135 2.0753E-05 5.9094E-15 2.6361E+10 7.6785E+05 Cs-134 1.7352E-01 1.3411E-07 6.0271E+17 6.4201E+09 Cs-136 4.0632E-02 5.5440E-10 2.4549E+15 1.5034E+09 Cs-137 9.4018E-02 1.0809E-06 4.7513E+18 3.4787E+09 I-130 6.1212E-05 3.1386E-14 1.4539E+11 2.2649E+06 Ba-137m 1.0422E-01 1.9379E-13 8.5185E+11 3.8562E+09 Br-82 2.8566E-04 2.6386E-13 1.9378E+12 1.0569E+07 Faulted S/G Transport Group Inventory:

Overlying Time (h) = 96.0000 Atmosphere Sump Pool Noble gases (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 96.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Faulted S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Compartment Atmosphere Nuclide Inventory:

Time (h) = 96.0000 Ci kg Atoms Bq Rb-86 3.3621E+00 4.1320E-08 2.8934E+17 1.2440E+11 Sr-89 2.7151E-01 9.3456E-09 6.3237E+16 1.0046E+10 I-131 7.0343E+02 5.6740E-06 2.6084E+19 2.6027E+13 I-132 2.4142E-10 2.3388E-20 1.0670E+05 8.9324E+00 I-133 4.9485E+01 4.3684E-08 1.9780E+17 1.8310E+12 I-135 4.8334E-02 1.3763E-11 6.1395E+13 1.7884E+09 Xe-133 1.3049E+02 6.9711E-07 3.1565E+18 4.8280E+12 Xe-135 1.8891E+00 7.3976E-10 3.2999E+15 6.9898E+10 Cs-134 4.0413E+02 3.1235E-04 1.4037E+21 1.4953E+13 Cs-136 9.4634E+01 1.2912E-06 5.7176E+18 3.5015E+12 Cs-137 2.1897E+02 2.5175E-03 1.1066E+22 8.1020E+12 I-130 1.4257E-01 7.3098E-11 3.3862E+14 5.2750E+09 Xe-131m 1.9249E+00 2.2981E-08 1.0564E+17 7.1222E+10 Xe-133m 5.5571E+00 1.2385E-08 5.6077E+16 2.0561E+11 Xe-135m 7.9545E-03 8.7324E-14 3.8954E+11 2.9432E+08 Cs-134m 1.0616E-08 1.3164E-18 5.9159E+06 3.9277E+02 Ba-137m 2.4274E+02 4.5135E-10 1.9840E+15 8.9813E+12 Br-82 6.6532E-01 6.1453E-10 4.5132E+15 2.4617E+10 Intact S/G Transport Group Inventory:

Overlying Time (h) = 96.0000 Atmosphere Sump Pool Noble gases (atoms) 3.3215E+18 0.0000E+00 0.0000E+00 Elemental I (atoms) 2.5498E+19 0.0000E+00 0.0000E+00 Organic I (atoms) 7.8859E+17 0.0000E+00 0.0000E+00 Aerosols (kg) 2.8311E-03 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 96.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Intact S/G Tube Leakage Transport Group Inventory:

Numerical Applications Inc. Attachment 5 Page 146 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Detailed model information at time (H) = 720.0000 EAB Doses:

Time (h) = 720.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 1.4970E-08 2.0487-177 6.2073E-08 1.4970E-08 Accumulated dose (rem) 4.7460E-01 2.1191E+02 7.3793E-01 1.1306E+01 LPZ Doses:

Time (h) = 720.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 7.0545E-11 9.6543-180 2.9251E-10 7.0545E-11 Accumulated dose (rem) 3.6700E-02 1.4097E+01 5.7902E-02 7.5497E-01 Control Room Doses:

Time (h) = 720.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 4.8853E-07 3.4461-174 6.8576E-05 4.8853E-07 Accumulated dose (rem) 1.3712E-02 7.9542E+01 7.7983E-01 4.0423E+00 PCS Compartment Atmosphere Nuclide Inventory:

Time (h) = 720.0000 Ci kg Atoms Bq Rb-86 3.1210E+02 3.8357E-06 2.6859E+19 1.1548E+13 Sr-89 4.6336E+01 1.5949E-06 1.0792E+19 1.7144E+12 I-131 1.8233E+04 1.4707E-04 6.7610E+20 6.7463E+14 I-133 1.1238E-05 9.9207E-15 4.4920E+10 4.1581E+05 Xe-133 1.1338E+03 6.0571E-06 2.7426E+19 4.1950E+13 Cs-134 9.6215E+04 7.4365E-02 3.3420E+23 3.5600E+15 Cs-136 5.8305E+03 7.9553E-05 3.5226E+20 2.1573E+14 Cs-137 5.3308E+04 6.1287E-01 2.6940E+24 1.9724E+15 Xe-131m 5.5390E+02 6.6129E-06 3.0400E+19 2.0494E+13 Xe-133m 4.1956E-01 9.3504E-10 4.2338E+15 1.5524E+10 Ba-137m 5.9094E+04 1.0988E-07 4.8300E+17 2.1865E+15 Br-82 7.7415E-04 7.1506E-13 5.2514E+12 2.8644E+07 PCS Transport Group Inventory:

Overlying Time (h) = 720.0000 Atmosphere Sump Pool Noble gases (atoms) 5.7830E+19 0.0000E+00 0.0000E+00 Elemental I (atoms) 6.5582E+20 0.0000E+00 0.0000E+00 Organic I (atoms) 2.0283E+19 0.0000E+00 0.0000E+00 Aerosols (kg) 6.8732E-01 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 720.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Faulted SG Tube Leakage Transport Group Inventory:

Pathway Time (h) = 720.0000 Filter

Numerical Applications Inc. Attachment 5 Page 147 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Tube Leakage Transport Group Inventory:

Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Environment Integral Nuclide Release:

Time (h) = 720.0000 Ci kg Atoms Bq Xe-131m 2.3576E+00 2.8146E-08 1.2939E+17 8.7229E+10 Environment Transport Group Inventory:

Present Release Integral Time (h) = 720.0000 Release Rate/s Release Noble gases (atoms) 9.4985E+08 1.3192E+07 2.4614E+17 Elemental I (atoms) 0.0000E+00 0.0000E+00 2.7902E+18 Organic I (atoms) 0.0000E+00 0.0000E+00 8.6294E+16 Aerosols (kg) 0.0000E+00 0.0000E+00 2.9242E-03 Faulted SG Tube Leakage Transport Group Inventory:

Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:

Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Filter Pathway Nuclide Inventory for Control Room Filtered Makeup Time (h) = 720.0000 Ci kg Atoms Bq Rb-86 4.5727E-04 5.6198E-12 3.9353E+13 1.6919E+07 Sr-89 6.7890E-05 2.3368E-12 1.5812E+13 2.5119E+06 I-131 2.6714E-02 2.1548E-10 9.9059E+14 9.8843E+08 Cs-134 1.4097E-01 1.0896E-07 4.8966E+17 5.2159E+09 Cs-136 8.5425E-03 1.1656E-10 5.1612E+14 3.1607E+08 Cs-137 7.8105E-02 8.9794E-07 3.9471E+18 2.8899E+09 Ba-137m 8.6581E-02 1.6099E-13 7.0767E+11 3.2035E+09 Br-82 1.1342E-09 1.0477E-18 7.6942E+06 4.1967E+01 Control Room Filtered Makeup Transport Group Inventory:

Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 9.6087E+14 Organic I (atoms) 2.9718E+13 Aerosols (kg) 1.0070E-06 Control Room Unfiltered Inleakage Transport Group Inventory:

Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00

Numerical Applications Inc. Attachment 5 Page 148 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:

Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Faulted S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Compartment Atmosphere Nuclide Inventory:

Time (h) = 720.0000 Ci kg Atoms Bq Xe-131m 3.7265E-07 4.4489E-15 2.0452E+10 1.3788E+04 Control Room Transport Group Inventory:

Overlying Time (h) = 720.0000 Atmosphere Sump Pool Noble gases (atoms) 2.0452E+10 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Recirculating Filter Inventory Time (h) = 720.0000 Ci kg Atoms Bq Rb-86 9.2261E-05 1.1339E-12 7.9400E+12 3.4136E+06 Sr-89 1.3698E-05 4.7149E-13 3.1903E+12 5.0681E+05 I-131 5.3900E-03 4.3477E-11 1.9986E+14 1.9943E+08 Cs-134 2.8443E-02 2.1983E-08 9.8796E+16 1.0524E+09 Cs-136 1.7236E-03 2.3517E-11 1.0413E+14 6.3772E+07 Cs-137 1.5759E-02 1.8117E-07 7.9638E+17 5.8307E+08 Ba-137m 1.7469E-02 3.2482E-14 1.4278E+11 6.4635E+08 Br-82 2.2885E-10 2.1138E-19 1.5524E+06 8.4675E+00 Deposition Recirculating Time (h) = 720.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 1.9387E+14 Organic I (atoms) 0.0000E+00 5.9959E+12 Aerosols (kg) 0.0000E+00 2.0318E-07 Control Room Unfiltered Makeup Transport Group Inventory:

Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Filter Pathway Nuclide Inventory for Control Room Filtered Makeup

Numerical Applications Inc. Attachment 5 Page 149 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Time (h) = 720.0000 Ci kg Atoms Bq Rb-86 4.5727E-04 5.6198E-12 3.9353E+13 1.6919E+07 Sr-89 6.7890E-05 2.3368E-12 1.5812E+13 2.5119E+06 I-131 2.6714E-02 2.1548E-10 9.9059E+14 9.8843E+08 Cs-134 1.4097E-01 1.0896E-07 4.8966E+17 5.2159E+09 Cs-136 8.5425E-03 1.1656E-10 5.1612E+14 3.1607E+08 Cs-137 7.8105E-02 8.9794E-07 3.9471E+18 2.8899E+09 Ba-137m 8.6581E-02 1.6099E-13 7.0767E+11 3.2035E+09 Br-82 1.1342E-09 1.0477E-18 7.6942E+06 4.1967E+01 Control Room Filtered Makeup Transport Group Inventory:

Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 9.6087E+14 Organic I (atoms) 2.9718E+13 Aerosols (kg) 1.0070E-06 Control Room Unfiltered Inleakage Transport Group Inventory:

Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:

Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Total Filter Nuclide Inventory:

Time (h) = 720.0000 Ci kg Atoms Bq Rb-86 5.4953E-04 6.7537E-12 4.7293E+13 2.0333E+07 Sr-89 8.1587E-05 2.8083E-12 1.9002E+13 3.0187E+06 I-131 3.2104E-02 2.5896E-10 1.1905E+15 1.1879E+09 Cs-134 1.6941E-01 1.3094E-07 5.8846E+17 6.2683E+09 Cs-136 1.0266E-02 1.4007E-10 6.2025E+14 3.7985E+08 Cs-137 9.3864E-02 1.0791E-06 4.7435E+18 3.4730E+09 Ba-137m 1.0405E-01 1.9347E-13 8.5045E+11 3.8499E+09 Br-82 1.3631E-09 1.2591E-18 9.2466E+06 5.0435E+01 Faulted S/G Transport Group Inventory:

Overlying Time (h) = 720.0000 Atmosphere Sump Pool Noble gases (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 720.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Faulted S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00

Numerical Applications Inc. Attachment 5 Page 150 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Aerosols (kg) 0.0000E+00 Intact S/G Compartment Atmosphere Nuclide Inventory:

Time (h) = 720.0000 Ci kg Atoms Bq Rb-86 1.2799E+00 1.5730E-08 1.1015E+17 4.7356E+10 Sr-89 1.9002E-01 6.5407E-09 4.4257E+16 7.0308E+09 I-131 7.4773E+01 6.0313E-07 2.7726E+18 2.7666E+12 I-133 4.6087E-08 4.0684E-17 1.8421E+08 1.7052E+03 Xe-133 4.6495E+00 2.4840E-08 1.1247E+17 1.7203E+11 Cs-134 3.9457E+02 3.0496E-04 1.3705E+21 1.4599E+13 Cs-136 2.3910E+01 3.2624E-07 1.4446E+18 8.8468E+11 Cs-137 2.1861E+02 2.5133E-03 1.1048E+22 8.0887E+12 Xe-131m 2.2715E+00 2.7119E-08 1.2467E+17 8.4045E+10 Xe-133m 1.7206E-03 3.8345E-12 1.7362E+13 6.3661E+07 Ba-137m 2.4234E+02 4.5061E-10 1.9807E+15 8.9665E+12 Br-82 3.1747E-06 2.9324E-15 2.1536E+10 1.1746E+05 Intact S/G Transport Group Inventory:

Overlying Time (h) = 720.0000 Atmosphere Sump Pool Noble gases (atoms) 2.3716E+17 0.0000E+00 0.0000E+00 Elemental I (atoms) 2.6894E+18 0.0000E+00 0.0000E+00 Organic I (atoms) 8.3178E+16 0.0000E+00 0.0000E+00 Aerosols (kg) 2.8186E-03 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 720.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Intact S/G Tube Leakage Transport Group Inventory:

Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Transport Group Totals in Model:

Noble Gases (atoms) 5.8313E+19 Elemental I (atoms) 6.6130E+20 Organic I (atoms) 2.0452E+19 Aerosols (kg) 6.9306E-01 36004 I-131 Summary PCS Environment Control Room Time (hr) I-131 (Curies) I-131 (Curies) I-131 (Curies) 0.001 1.3566E+05 1.3015E-02 5.3313E-05 0.001 2.4419E+05 2.9153E-02 1.7270E-04 0.280 2.4390E+05 2.3569E+01 8.3133E-02 0.333 2.4384E+05 2.8069E+01 9.6285E-02

Numerical Applications Inc. Attachment 5 Page 151 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 0.600 2.4356E+05 5.0666E+01 2.8217E-02 0.860 2.4329E+05 7.2667E+01 9.1280E-03 1.120 2.4302E+05 9.4657E+01 3.5320E-03 1.380 2.4275E+05 1.1664E+02 1.8921E-03 1.640 2.4248E+05 1.3862E+02 1.4123E-03 1.900 2.4221E+05 1.6059E+02 1.2725E-03 2.000 2.4210E+05 1.6904E+02 1.2510E-03 2.260 2.4183E+05 1.9100E+02 1.1038E-03 2.520 2.4157E+05 2.1296E+02 1.0614E-03 2.780 2.4130E+05 2.3492E+02 1.0496E-03 3.040 2.4103E+05 2.5687E+02 1.0469E-03 3.300 2.4076E+05 2.7881E+02 1.0468E-03 3.560 2.4049E+05 3.0075E+02 1.0475E-03 3.820 2.4022E+05 3.2268E+02 1.0484E-03 4.080 2.3996E+05 3.4460E+02 1.0493E-03 4.340 2.3969E+05 3.6652E+02 1.0503E-03 4.600 2.3942E+05 3.8843E+02 1.0512E-03 4.860 2.3915E+05 4.1033E+02 1.0522E-03 5.120 2.3889E+05 4.3223E+02 1.0531E-03 5.380 2.3862E+05 4.5412E+02 1.0541E-03 5.640 2.3836E+05 4.7601E+02 1.0550E-03 5.900 2.3809E+05 4.9788E+02 1.0559E-03 6.160 2.3783E+05 5.1975E+02 1.0569E-03 6.420 2.3756E+05 5.4162E+02 1.0578E-03 6.680 2.3730E+05 5.6347E+02 1.0587E-03 6.940 2.3703E+05 5.8532E+02 1.0596E-03 7.200 2.3677E+05 6.0716E+02 1.0605E-03 7.460 2.3650E+05 6.2899E+02 1.0614E-03 7.720 2.3624E+05 6.5081E+02 1.0623E-03 7.980 2.3598E+05 6.7263E+02 1.0631E-03 8.000 2.3596E+05 6.7431E+02 1.0632E-03 8.260 2.3570E+05 6.9493E+02 6.0334E-04 8.520 2.3543E+05 7.1551E+02 4.6818E-04 8.780 2.3517E+05 7.3604E+02 4.2823E-04 9.040 2.3491E+05 7.5653E+02 4.1619E-04 9.300 2.3465E+05 7.7698E+02 4.1234E-04 9.560 2.3439E+05 7.9739E+02 4.1089E-04 9.820 2.3412E+05 8.1775E+02 4.1014E-04 10.080 2.3386E+05 8.3807E+02 4.0960E-04 12.000 2.3195E+05 9.8682E+02 4.0620E-04 24.000 2.2216E+05 9.4519E+02 1.0391E-28 96.000 1.7153E+05 7.2978E+02 2.9109-176 720.000 1.8233E+04 7.7573E+01 0.0000E+00 Faulted S/G Intact S/G Time (hr) I-131 (Curies) I-131 (Curies) 0.001 0.0000E+00 1.3068E-02 0.001 0.0000E+00 4.2340E-02 0.280 0.0000E+00 2.3619E+01 0.333 0.0000E+00 2.8112E+01 0.600 0.0000E+00 5.0539E+01 0.860 0.0000E+00 7.2316E+01 1.120 0.0000E+00 9.4009E+01 1.380 0.0000E+00 1.1562E+02 1.640 0.0000E+00 1.3714E+02 1.900 0.0000E+00 1.5858E+02 2.000 0.0000E+00 1.6681E+02 2.260 0.0000E+00 1.8813E+02 2.520 0.0000E+00 2.0937E+02 2.780 0.0000E+00 2.3053E+02 3.040 0.0000E+00 2.5160E+02 3.300 0.0000E+00 2.7259E+02 3.560 0.0000E+00 2.9350E+02 3.820 0.0000E+00 3.1433E+02 4.080 0.0000E+00 3.3508E+02 4.340 0.0000E+00 3.5574E+02 4.600 0.0000E+00 3.7632E+02 4.860 0.0000E+00 3.9682E+02 5.120 0.0000E+00 4.1725E+02 5.380 0.0000E+00 4.3759E+02 5.640 0.0000E+00 4.5784E+02 5.900 0.0000E+00 4.7802E+02 6.160 0.0000E+00 4.9812E+02

Numerical Applications Inc. Attachment 5 Page 152 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 6.420 0.0000E+00 5.1814E+02 6.680 0.0000E+00 5.3808E+02 6.940 0.0000E+00 5.5795E+02 7.200 0.0000E+00 5.7773E+02 7.460 0.0000E+00 5.9743E+02 7.720 0.0000E+00 6.1706E+02 7.980 0.0000E+00 6.3661E+02 8.000 0.0000E+00 6.3811E+02 8.260 0.0000E+00 6.5876E+02 8.520 0.0000E+00 6.7938E+02 8.780 0.0000E+00 6.9995E+02 9.040 0.0000E+00 7.2048E+02 9.300 0.0000E+00 7.4097E+02 9.560 0.0000E+00 7.6141E+02 9.820 0.0000E+00 7.8181E+02 10.080 0.0000E+00 8.0217E+02 12.000 0.0000E+00 9.5119E+02 24.000 0.0000E+00 9.1106E+02 96.000 0.0000E+00 7.0343E+02 720.000 0.0000E+00 7.4773E+01 Cumulative Dose Summary EAB LPZ Control Room Time Thyroid TEDE Thyroid TEDE Thyroid TEDE (hr) (rem) (rem) (rem) (rem) (rem) (rem) 0.001 3.3623E-03 1.9580E-04 4.1546E-04 2.4194E-05 2.5121E-05 1.2771E-06 0.001 1.0894E-02 6.3436E-04 1.3461E-03 7.8383E-05 1.1032E-04 5.6084E-06 0.280 6.0883E+00 3.4887E-01 7.5228E-01 4.3107E-02 2.0678E+01 1.0494E+00 0.333 7.2487E+00 4.1417E-01 8.9566E-01 5.1176E-02 2.8771E+01 1.4597E+00 0.600 1.3072E+01 7.3770E-01 1.6152E+00 9.1151E-02 5.3705E+01 2.7230E+00 0.860 1.8734E+01 1.0473E+00 2.3148E+00 1.2940E-01 6.1059E+01 3.0952E+00 1.120 2.4385E+01 1.3529E+00 3.0131E+00 1.6716E-01 6.3584E+01 3.2230E+00 1.380 3.0028E+01 1.6556E+00 3.7103E+00 2.0457E-01 6.4696E+01 3.2793E+00 1.640 3.5662E+01 1.9563E+00 4.4065E+00 2.4172E-01 6.5395E+01 3.3147E+00 1.900 4.1289E+01 2.2553E+00 5.1018E+00 2.7866E-01 6.5972E+01 3.3440E+00 2.000 4.3451E+01 2.3699E+00 5.3689E+00 2.9283E-01 6.6182E+01 3.3547E+00 2.260 4.9068E+01 2.6672E+00 5.6847E+00 3.0954E-01 6.6686E+01 3.3802E+00 2.520 5.4678E+01 2.9635E+00 6.0000E+00 3.2620E-01 6.7152E+01 3.4039E+00 2.780 6.0281E+01 3.2590E+00 6.3150E+00 3.4281E-01 6.7607E+01 3.4270E+00 3.040 6.5877E+01 3.5538E+00 6.6296E+00 3.5938E-01 6.8058E+01 3.4500E+00 3.300 7.1466E+01 3.8480E+00 6.9438E+00 3.7592E-01 6.8508E+01 3.4729E+00 3.560 7.7049E+01 4.1418E+00 7.2576E+00 3.9244E-01 6.8958E+01 3.4958E+00 3.820 8.2626E+01 4.4351E+00 7.5711E+00 4.0892E-01 6.9407E+01 3.5187E+00 4.080 8.8196E+01 4.7280E+00 7.8843E+00 4.2539E-01 6.9855E+01 3.5416E+00 4.340 9.3761E+01 5.0206E+00 8.1971E+00 4.4184E-01 7.0303E+01 3.5644E+00 4.600 9.9319E+01 5.3129E+00 8.5096E+00 4.5827E-01 7.0751E+01 3.5873E+00 4.860 1.0487E+02 5.6049E+00 8.8217E+00 4.7469E-01 7.1199E+01 3.6102E+00 5.120 1.1042E+02 5.8967E+00 9.1335E+00 4.9109E-01 7.1646E+01 3.6331E+00 5.380 1.1596E+02 6.1882E+00 9.4451E+00 5.0748E-01 7.2093E+01 3.6560E+00 5.640 1.2150E+02 6.4796E+00 9.7563E+00 5.2385E-01 7.2539E+01 3.6789E+00 5.900 1.2703E+02 6.7707E+00 1.0067E+01 5.4022E-01 7.2986E+01 3.7018E+00 6.160 1.3255E+02 7.0617E+00 1.0378E+01 5.5658E-01 7.3432E+01 3.7247E+00 6.420 1.3807E+02 7.3525E+00 1.0688E+01 5.7293E-01 7.3877E+01 3.7477E+00 6.680 1.4359E+02 7.6431E+00 1.0998E+01 5.8927E-01 7.4323E+01 3.7706E+00 6.940 1.4910E+02 7.9337E+00 1.1308E+01 6.0560E-01 7.4768E+01 3.7935E+00 7.200 1.5460E+02 8.2241E+00 1.1617E+01 6.2192E-01 7.5213E+01 3.8164E+00 7.460 1.6010E+02 8.5143E+00 1.1927E+01 6.3824E-01 7.5657E+01 3.8394E+00 7.720 1.6560E+02 8.8045E+00 1.2235E+01 6.5455E-01 7.6101E+01 3.8623E+00 7.980 1.7109E+02 9.0945E+00 1.2544E+01 6.7086E-01 7.6545E+01 3.8853E+00 8.000 1.7151E+02 9.1168E+00 1.2568E+01 6.7211E-01 7.6580E+01 3.8870E+00 8.260 1.7418E+02 9.2613E+00 1.2669E+01 6.7758E-01 7.6908E+01 3.9040E+00 8.520 1.7685E+02 9.4054E+00 1.2770E+01 6.8303E-01 7.7126E+01 3.9153E+00 8.780 1.7951E+02 9.5492E+00 1.2871E+01 6.8847E-01 7.7311E+01 3.9249E+00 9.040 1.8216E+02 9.6927E+00 1.2971E+01 6.9390E-01 7.7486E+01 3.9340E+00 9.300 1.8481E+02 9.8359E+00 1.3071E+01 6.9932E-01 7.7657E+01 3.9429E+00 9.560 1.8745E+02 9.9788E+00 1.3171E+01 7.0473E-01 7.7828E+01 3.9518E+00 9.820 1.9008E+02 1.0121E+01 1.3271E+01 7.1013E-01 7.7998E+01 3.9607E+00 10.080 1.9271E+02 1.0264E+01 1.3370E+01 7.1552E-01 7.8167E+01 3.9695E+00 12.000 2.1191E+02 1.1306E+01 1.4097E+01 7.5497E-01 7.9406E+01 4.0343E+00 24.000 2.1191E+02 1.1306E+01 1.4097E+01 7.5497E-01 7.9542E+01 4.0421E+00

Numerical Applications Inc. Attachment 5 Page 153 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 96.000 2.1191E+02 1.1306E+01 1.4097E+01 7.5497E-01 7.9542E+01 4.0423E+00 720.000 2.1191E+02 1.1306E+01 1.4097E+01 7.5497E-01 7.9542E+01 4.0423E+00 Worst Two-Hour Dose (Provided for Dose Location 1)

EAB Time Whole Body Thyroid Skin TEDE (hr) (rem) (rem) (rem) (rem) 0.0 1.7421E-01 4.3448E+01 2.8270E-01 2.3697E+00 30 Day Control Room Skin Dose Control Room Time Skin (hr) (rem) 720.0 7.7983E-01

Numerical Applications Inc. Attachment 6 Page 154 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Palisades MSLB Secondary Dose (pal_MSLB_sg_db_ast.out)

RADTRAD-NAI Version 1.1a(QA) run on May 26, 2006 at 14:11:50 File information Plant file name = AST/MSLB/pal_MSLB_sg_db_ast.psf Inventory file name = AST/MSLB/pal_mslb_sg_db.nif Scenario file name = AST/MSLB/pal_MSLB_sg_db_ast.psf Release file name = AST/MSLB/pal_mslb_sg.rft Dose conversion file name = AST/MSLB/nai-1101-001rev0.dcf

  • RADTRAD-NAI 1.1a(QA)
  • 26 May 2006 14:11:40
    • S/G Initial Iodine Activity Dose
  • Nuclide inventory file AST/MSLB/pal_mslb_sg_db.nif
  • Plant power 2703
  • Compartments 5
  • Compartment 1:

PCS 3

432977 0

0 0

0

  • Compartment 2:

Environment 2

2e+20 0

0 0

0

  • Compartment 3:

Control Room 1

35923 0

1 0

0

  • Compartment 4:

Faulted S/G 3

210759 0

0 0

0

Numerical Applications Inc. Attachment 6 Page 155 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1

  • Compartment 5:

Intact S/G 3

141065 0

0 0

0

  • Pathways 8
  • Pathway 1:

Faulted SG Tube Leakage 1

2 2

  • Pathway 2:

Control Room Unfiltered Makeup 2

3 2

  • Pathway 3:

Control Room Filtered Makeup 2

3 2

  • Pathway 4:

Control Room Unfiltered Inleakage 2

3 2

  • Pathway 5:

Control Room Exhaust 3

2 2

  • Pathway 6:

Intact S/G Tube Leakage 1

5 2

  • Pathway 7:

Intact S/G Steam Release 5

2 2

  • Pathway 8:

Faulted S/G Steam Release 4

2 2

  • Sources 5

1 0 2 0 3 0 4 9.56 5 6.4

  • dose conversion factors filename AST/MSLB/nai-1101-001rev0.dcf
  • release fraction and timing filename AST/MSLB/pal_mslb_sg.rft 0

1 1

  • Iodine 0 0.97 0.03
  • Overlying pool
  • aerosol model 0
  • elemental model 0
  • organic model 0

Numerical Applications Inc. Attachment 6 Page 156 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1

  • pH tracking 0
  • Compartment detail
  • Compartment 1:

1

  • spray model 0

0 0

  • filter model 0
  • deposition model 0

0

  • Compartment 2:

1

  • spray model 0

0 0

  • filter model 0
  • deposition model 0

0

  • Compartment 3:

1

  • spray model 0

0 0

  • filter model 1

3 0 0 99 99 99 0.3333 1413.6 99 99 99 720 1413.6 99 99 99

  • deposition model 0

0

  • Compartment 4:

1

  • spray model 0

0 0

  • filter model 0
  • deposition model 0

0

  • Compartment 5:

1

  • spray model 0

0 0

  • filter model 0
  • deposition model 0

0

  • Pathways:
  • Pathway 1
  • filter efficiency model 1

3 0 0 0 0 0 12 0 0 0 0 720 0 0 0 0

  • Pathway 2
  • filter efficiency model 1

Numerical Applications Inc. Attachment 6 Page 157 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 3

0 660 0 0 0 0.3333 0 0 0 0 720 0 0 0 0

  • Pathway 3
  • filter efficiency model 1

3 0 0 99 99 99 0.3333 1413.6 99 99 99 720 1413.6 99 99 99

  • Pathway 4
  • filter efficiency model 1

3 0 0 0 0 0 0.3333 10 0 0 0 720 10 0 0 0

  • Pathway 5
  • filter efficiency model 1

3 0 660 0 0 0 0.3333 1423.6 0 0 0 720 1423.6 0 0 0

  • Pathway 6
  • filter efficiency model 1

3 0 0 0 0 0 12 0 0 0 0 720 0 0 0 0

  • Pathway 7
  • filter efficiency model 1

3 0 16.67 0 0 0 8 0 0 0 0 720 0 0 0 0

  • Pathway 8
  • filter efficiency model 1

2 0 1000000 0 0 0 720 1000000 0 0 0

  • x/q tables 6

EAB 2

0 0.000539 720 0.000539 LPZ 6

0 6.66e-05 2 3.03e-05 8 2.04e-05 24 8.67e-06 96 2.54e-06 720 2.54e-06 Control Room Unfiltered 6

0 0.0131 2 0.0113 8 0.00468 24 0.00287 96 0.00236 720 0.00236 Control Room Filtered 6

0 0.000799 2 0.000643 8 0.000258 24 0.000175

Numerical Applications Inc. Attachment 6 Page 158 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 96 0.000132 720 0.000132 ADV-Normal 6

0 0.0165 2 0.0134 8 0.0054 24 0.00403 96 0.00298 720 0.00298 ADV-Emergency 6

0 0.000736 2 0.000642 8 0.000243 24 0.000175 96 0.000128 720 0.000128

  • dose locations 3
  • location name, compartment number and x/q table EAB 2

1

  • br model 1

4 0 0.00035 8 0.00018 24 0.00023 720 0.00023

  • of model 0
  • location x/q input to be included 0
  • location name, compartment number and x/q table LPZ 2

2

  • br model 1

4 0 0.00035 8 0.00018 24 0.00023 720 0.00023

  • of model 0
  • location x/q input to be included 0
  • location name, compartment number and x/q table Control Room 3

0

  • br model 1

2 0 0.00035 720 0.00035

  • of model 1

4 0 1 24 0.6 96 0.4 720 0.4

  • location x/q input to be included 1
  • number of intake combinations 9
  • intake combinations 2 1 3 3 1 4

Numerical Applications Inc. Attachment 6 Page 159 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 4 1 3 2 7 5 3 7 6 4 7 5 2 8 3 3 8 4 4 8 3

  • time step count 1

0 0.02

  • show plant, scenario, event, step, model 1

1 1

0 1

RADTRAD-NAI Version 1.1a(QA) run on May 26, 2006 at 14:11:50 Plant Description Number of Nuclides = 107 Inventory Power = 2.7030E+03 MWth Plant Power Level = 2.7030E+03 MWth Number of compartments = 5 Compartment information Compartment number 1 Name: PCS Compartment volume = 4.3298E+05 (Cubic feet)

Pathways into and out of compartment 1 Pathway to compartment number 2: Faulted SG Tube Leakage Pathway to compartment number 5: Intact S/G Tube Leakage Compartment number 2 Name: Environment Pathways into and out of compartment 2 Pathway to compartment number 3: Control Room Unfiltered Makeup Pathway to compartment number 3: Control Room Filtered Makeup Pathway to compartment number 3: Control Room Unfiltered Inleakage Pathway from compartment number 1: Faulted SG Tube Leakage Pathway from compartment number 3: Control Room Exhaust Pathway from compartment number 5: Intact S/G Steam Release Pathway from compartment number 4: Faulted S/G Steam Release Compartment number 3 Name: Control Room Compartment volume = 3.5923E+04 (Cubic feet)

Removal devices within compartment:

Filter(s)

Pathways into and out of compartment 3 Pathway to compartment number 2: Control Room Exhaust Pathway from compartment number 2: Control Room Unfiltered Makeup Pathway from compartment number 2: Control Room Filtered Makeup Pathway from compartment number 2: Control Room Unfiltered Inleakage Compartment number 4 (Source term fraction = 9.5600E+00)

Name: Faulted S/G Compartment volume = 2.1076E+05 (Cubic feet)

Pathways into and out of compartment 4 Pathway to compartment number 2: Faulted S/G Steam Release Compartment number 5 (Source term fraction = 6.4000E+00)

Name: Intact S/G Compartment volume = 1.4106E+05 (Cubic feet)

Pathways into and out of compartment 5

Numerical Applications Inc. Attachment 6 Page 160 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Pathway to compartment number 2: Intact S/G Steam Release Pathway from compartment number 1: Intact S/G Tube Leakage Total number of pathways = 8 RADTRAD-NAI Version 1.1a(QA) run on May 26, 2006 at 14:11:50 Scenario Description Radioactive Decay is enabled Calculation of Daughters is enabled Iodine fractions Aerosol = 0.0000E+00 Elemental = 9.7000E-01 Organic = 3.0000E-02 COMPARTMENT DATA Compartment number 1: PCS Compartment number 2: Environment Compartment number 3: Control Room Compartment Filter Data Time (hr) Flow Rate Filter Efficiencies (%)

(cfm) Aerosol Elemental Organic 0.0000E+00 0.0000E+00 9.9000E+01 9.9000E+01 9.9000E+01 3.3330E-01 1.4136E+03 9.9000E+01 9.9000E+01 9.9000E+01 7.2000E+02 1.4136E+03 9.9000E+01 9.9000E+01 9.9000E+01 Compartment number 4: Faulted S/G Compartment number 5: Intact S/G PATHWAY DATA Pathway number 1: Faulted SG Tube Leakage Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)

(cfm) Aerosol Elemental Organic 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 1.2000E+01 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Pathway number 2: Control Room Unfiltered Makeup Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)

(cfm) Aerosol Elemental Organic 0.0000E+00 6.6000E+02 0.0000E+00 0.0000E+00 0.0000E+00 3.3330E-01 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Pathway number 3: Control Room Filtered Makeup Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)

(cfm) Aerosol Elemental Organic 0.0000E+00 0.0000E+00 9.9000E+01 9.9000E+01 9.9000E+01 3.3330E-01 1.4136E+03 9.9000E+01 9.9000E+01 9.9000E+01 7.2000E+02 1.4136E+03 9.9000E+01 9.9000E+01 9.9000E+01

Numerical Applications Inc. Attachment 6 Page 161 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Pathway number 4: Control Room Unfiltered Inleakage Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)

(cfm) Aerosol Elemental Organic 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 3.3330E-01 1.0000E+01 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 1.0000E+01 0.0000E+00 0.0000E+00 0.0000E+00 Pathway number 5: Control Room Exhaust Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)

(cfm) Aerosol Elemental Organic 0.0000E+00 6.6000E+02 0.0000E+00 0.0000E+00 0.0000E+00 3.3330E-01 1.4236E+03 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 1.4236E+03 0.0000E+00 0.0000E+00 0.0000E+00 Pathway number 6: Intact S/G Tube Leakage Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)

(cfm) Aerosol Elemental Organic 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 1.2000E+01 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Pathway number 7: Intact S/G Steam Release Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)

(cfm) Aerosol Elemental Organic 0.0000E+00 1.6670E+01 0.0000E+00 0.0000E+00 0.0000E+00 8.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Pathway number 8: Faulted S/G Steam Release Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)

(cfm) Aerosol Elemental Organic 0.0000E+00 1.0000E+06 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 1.0000E+06 0.0000E+00 0.0000E+00 0.0000E+00 X/Q DATA X/Q table 1: EAB Time (hr) X/Q (s

  • m^-3) 0.0000E+00 5.3900E-04 7.2000E+02 5.3900E-04 X/Q table 2: LPZ Time (hr) X/Q (s
  • m^-3) 0.0000E+00 6.6600E-05 2.0000E+00 3.0300E-05 8.0000E+00 2.0400E-05 2.4000E+01 8.6700E-06 9.6000E+01 2.5400E-06 7.2000E+02 2.5400E-06 X/Q table 3: Control Room Unfiltered Time (hr) X/Q (s
  • m^-3) 0.0000E+00 1.3100E-02 2.0000E+00 1.1300E-02 8.0000E+00 4.6800E-03 2.4000E+01 2.8700E-03 9.6000E+01 2.3600E-03

Numerical Applications Inc. Attachment 6 Page 162 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 7.2000E+02 2.3600E-03 X/Q table 4: Control Room Filtered Time (hr) X/Q (s

  • m^-3) 0.0000E+00 7.9900E-04 2.0000E+00 6.4300E-04 8.0000E+00 2.5800E-04 2.4000E+01 1.7500E-04 9.6000E+01 1.3200E-04 7.2000E+02 1.3200E-04 X/Q table 5: ADV-Normal Time (hr) X/Q (s
  • m^-3) 0.0000E+00 1.6500E-02 2.0000E+00 1.3400E-02 8.0000E+00 5.4000E-03 2.4000E+01 4.0300E-03 9.6000E+01 2.9800E-03 7.2000E+02 2.9800E-03 X/Q table 6: ADV-Emergency Time (hr) X/Q (s
  • m^-3) 0.0000E+00 7.3600E-04 2.0000E+00 6.4200E-04 8.0000E+00 2.4300E-04 2.4000E+01 1.7500E-04 9.6000E+01 1.2800E-04 7.2000E+02 1.2800E-04 LOCATION DATA Location EAB is in compartment 2 Using X/Q Table 1 Location Breathing Rate Data Time (hr) Breathing Rate (m^3
  • sec^-1) 0.0000E+00 3.5000E-04 8.0000E+00 1.8000E-04 2.4000E+01 2.3000E-04 7.2000E+02 2.3000E-04 Location LPZ is in compartment 2 Using X/Q Table 2 Location Breathing Rate Data Time (hr) Breathing Rate (m^3
  • sec^-1) 0.0000E+00 3.5000E-04 8.0000E+00 1.8000E-04 2.4000E+01 2.3000E-04 7.2000E+02 2.3000E-04 Location Control Room is in compartment 3 Inleakage X/Q Table Assignments Inleakage Path Source Path X/Q Table 2 1 3 3 1 4 4 1 3 2 7 5 3 7 6 4 7 5 2 8 3 3 8 4 4 8 3 Location Breathing Rate Data Time (hr) Breathing Rate (m^3
  • sec^-1) 0.0000E+00 3.5000E-04 7.2000E+02 3.5000E-04 Location Occupancy Factor Data

Numerical Applications Inc. Attachment 6 Page 163 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Time (hr) Occupancy Factor 0.0000E+00 1.0000E+00 2.4000E+01 6.0000E-01 9.6000E+01 4.0000E-01 7.2000E+02 4.0000E-01 USER SPECIFIED TIME STEP DATA - SUPPLEMENTAL TIME STEPS Time Time step 0.0000E+00 2.0000E-02 RADTRAD-NAI Version 1.1a(QA) run on May 26, 2006 at 14:11:50 Dose, Detailed Model and Detailed Inventory Output Detailed model information at time (H) = 0.0010 EAB Doses:

Time (h) = 0.0010 Whole Body Thyroid Skin TEDE Delta dose (rem) 4.4837E-05 2.5178E-01 7.3415E-05 7.7103E-03 Accumulated dose (rem) 4.4837E-05 2.5178E-01 7.3415E-05 7.7103E-03 LPZ Doses:

Time (h) = 0.0010 Whole Body Thyroid Skin TEDE Delta dose (rem) 5.5402E-06 3.1110E-02 9.0713E-06 9.5270E-04 Accumulated dose (rem) 5.5402E-06 3.1110E-02 9.0713E-06 9.5270E-04 Control Room Doses:

Time (h) = 0.0010 Whole Body Thyroid Skin TEDE Delta dose (rem) 1.3640E-08 2.5930E-03 7.5608E-07 7.8958E-05 Accumulated dose (rem) 1.3640E-08 2.5930E-03 7.5608E-07 7.8958E-05 PCS Transport Group Inventory:

Overlying Time (h) = 0.0010 Atmosphere Sump Pool Noble gases (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 0.0010 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Faulted SG Tube Leakage Transport Group Inventory:

Pathway Time (h) = 0.0010 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00

Numerical Applications Inc. Attachment 6 Page 164 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Tube Leakage Transport Group Inventory:

Pathway Time (h) = 0.0010 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Environment Integral Nuclide Release:

Time (h) = 0.0010 Ci kg Atoms Bq I-131 8.3823E-01 6.7613E-09 3.1082E+16 3.1014E+10 Xe-131m 1.8739E-08 2.2372E-16 1.0284E+09 6.9333E+02 Environment Transport Group Inventory:

Present Release Integral Time (h) = 0.0010 Release Rate/s Release Noble gases (atoms) 1.0284E+09 5.1422E+08 1.0284E+09 Elemental I (atoms) 3.0150E+16 1.5075E+16 3.0150E+16 Organic I (atoms) 9.3246E+14 4.6623E+14 9.3246E+14 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Faulted SG Tube Leakage Transport Group Inventory:

Pathway Time (h) = 0.0010 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:

Pathway Time (h) = 0.0010 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Filtered Makeup Transport Group Inventory:

Pathway Time (h) = 0.0010 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Inleakage Transport Group Inventory:

Pathway Time (h) = 0.0010 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:

Pathway Time (h) = 0.0010 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Steam Release Transport Group Inventory:

Numerical Applications Inc. Attachment 6 Page 165 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Pathway Time (h) = 0.0010 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Faulted S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 0.0010 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Compartment Atmosphere Nuclide Inventory:

Time (h) = 0.0010 Ci kg Atoms Bq I-131 5.0594E-03 4.0810E-11 1.8761E+14 1.8720E+08 Xe-131m 1.2056E-10 1.4393E-18 6.6165E+06 4.4606E+00 Control Room Transport Group Inventory:

Overlying Time (h) = 0.0010 Atmosphere Sump Pool Noble gases (atoms) 6.6165E+06 0.0000E+00 0.0000E+00 Elemental I (atoms) 1.8198E+14 0.0000E+00 0.0000E+00 Organic I (atoms) 5.6282E+12 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 0.0010 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:

Pathway Time (h) = 0.0010 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Filtered Makeup Transport Group Inventory:

Pathway Time (h) = 0.0010 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Inleakage Transport Group Inventory:

Pathway Time (h) = 0.0010 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:

Pathway Time (h) = 0.0010 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00

Numerical Applications Inc. Attachment 6 Page 166 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Aerosols (kg) 0.0000E+00 Faulted S/G Compartment Atmosphere Nuclide Inventory:

Time (h) = 0.0010 Ci kg Atoms Bq I-131 8.3196E+00 6.7107E-08 3.0850E+17 3.0783E+11 Xe-131m 1.6439E-07 1.9627E-15 9.0225E+09 6.0826E+03 Faulted S/G Transport Group Inventory:

Overlying Time (h) = 0.0010 Atmosphere Sump Pool Noble gases (atoms) 9.0225E+09 0.0000E+00 0.0000E+00 Elemental I (atoms) 2.9924E+17 0.0000E+00 0.0000E+00 Organic I (atoms) 9.2549E+15 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 0.0010 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Faulted S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 0.0010 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Compartment Atmosphere Nuclide Inventory:

Time (h) = 0.0010 Ci kg Atoms Bq I-131 6.4000E+00 5.1623E-08 2.3731E+17 2.3680E+11 Xe-131m 1.2984E-07 1.5501E-15 7.1261E+09 4.8041E+03 Intact S/G Transport Group Inventory:

Overlying Time (h) = 0.0010 Atmosphere Sump Pool Noble gases (atoms) 7.1261E+09 0.0000E+00 0.0000E+00 Elemental I (atoms) 2.3019E+17 0.0000E+00 0.0000E+00 Organic I (atoms) 7.1194E+15 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 0.0010 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Intact S/G Tube Leakage Transport Group Inventory:

Pathway Time (h) = 0.0010 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 0.0010 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00

Numerical Applications Inc. Attachment 6 Page 167 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Detailed model information at time (H) = 0.3333 EAB Doses:

Time (h) = 0.3333 Whole Body Thyroid Skin TEDE Delta dose (rem) 3.0171E-04 1.6942E+00 4.9401E-04 5.1883E-02 Accumulated dose (rem) 3.4655E-04 1.9460E+00 5.6743E-04 5.9593E-02 LPZ Doses:

Time (h) = 0.3333 Whole Body Thyroid Skin TEDE Delta dose (rem) 3.7280E-05 2.0934E-01 6.1041E-05 6.4108E-03 Accumulated dose (rem) 4.2821E-05 2.4045E-01 7.0113E-05 7.3635E-03 Control Room Doses:

Time (h) = 0.3333 Whole Body Thyroid Skin TEDE Delta dose (rem) 7.4405E-05 1.4144E+01 4.1243E-03 4.3070E-01 Accumulated dose (rem) 7.4419E-05 1.4147E+01 4.1250E-03 4.3078E-01 PCS Transport Group Inventory:

Overlying Time (h) = 0.3333 Atmosphere Sump Pool Noble gases (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 0.3333 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Faulted SG Tube Leakage Transport Group Inventory:

Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Tube Leakage Transport Group Inventory:

Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Environment Integral Nuclide Release:

Time (h) = 0.3333 Ci kg Atoms Bq I-131 9.1398E+00 7.3723E-08 3.3891E+17 3.3817E+11 Xe-131m 8.2021E-05 9.7922E-13 4.5015E+12 3.0348E+06 Environment Transport Group Inventory:

Present Release Integral Time (h) = 0.3333 Release Rate/s Release Noble gases (atoms) 4.9231E+08 6.8376E+06 4.5015E+12 Elemental I (atoms) 3.5952E+13 4.9933E+11 3.2874E+17 Organic I (atoms) 1.1119E+12 1.5443E+10 1.0167E+16 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Faulted SG Tube Leakage Transport Group Inventory:

Pathway Time (h) = 0.3333 Filter

Numerical Applications Inc. Attachment 6 Page 168 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:

Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Filtered Makeup Transport Group Inventory:

Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Inleakage Transport Group Inventory:

Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:

Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Faulted S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Compartment Atmosphere Nuclide Inventory:

Time (h) = 0.3333 Ci kg Atoms Bq I-131 2.7167E-02 2.1913E-10 1.0074E+15 1.0052E+09 Xe-131m 2.4380E-07 2.9107E-15 1.3381E+10 9.0207E+03 Control Room Transport Group Inventory:

Overlying Time (h) = 0.3333 Atmosphere Sump Pool Noble gases (atoms) 1.3381E+10 0.0000E+00 0.0000E+00 Elemental I (atoms) 9.7715E+14 0.0000E+00 0.0000E+00 Organic I (atoms) 3.0221E+13 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00

Numerical Applications Inc. Attachment 6 Page 169 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Deposition Recirculating Time (h) = 0.3333 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:

Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Filtered Makeup Transport Group Inventory:

Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Inleakage Transport Group Inventory:

Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:

Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Faulted S/G Transport Group Inventory:

Overlying Time (h) = 0.3333 Atmosphere Sump Pool Noble gases (atoms) 3.3676E-29 0.0000E+00 0.0000E+00 Elemental I (atoms) 2.4594E-24 0.0000E+00 0.0000E+00 Organic I (atoms) 7.6064E-26 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 0.3333 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Faulted S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Compartment Atmosphere Nuclide Inventory:

Time (h) = 0.3333 Ci kg Atoms Bq I-131 6.3773E+00 5.1440E-08 2.3647E+17 2.3596E+11

Numerical Applications Inc. Attachment 6 Page 170 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Xe-131m 5.7231E-05 6.8327E-13 3.1410E+12 2.1176E+06 Intact S/G Transport Group Inventory:

Overlying Time (h) = 0.3333 Atmosphere Sump Pool Noble gases (atoms) 3.1410E+12 0.0000E+00 0.0000E+00 Elemental I (atoms) 2.2938E+17 0.0000E+00 0.0000E+00 Organic I (atoms) 7.0942E+15 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 0.3333 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Intact S/G Tube Leakage Transport Group Inventory:

Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 0.3333 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Detailed model information at time (H) = 2.0000 EAB Doses:

Time (h) = 2.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 3.2065E-06 1.8006E-02 5.2503E-06 5.5140E-04 Accumulated dose (rem) 3.4976E-04 1.9640E+00 5.7268E-04 6.0145E-02 LPZ Doses:

Time (h) = 2.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 3.9621E-07 2.2249E-03 6.4874E-07 6.8133E-05 Accumulated dose (rem) 4.3217E-05 2.4268E-01 7.0762E-05 7.4316E-03 Control Room Doses:

Time (h) = 2.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 4.0552E-05 7.7090E+00 2.2478E-03 2.3474E-01 Accumulated dose (rem) 1.1497E-04 2.1856E+01 6.3729E-03 6.6552E-01 PCS Transport Group Inventory:

Overlying Time (h) = 2.0000 Atmosphere Sump Pool Noble gases (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 2.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Faulted SG Tube Leakage Transport Group Inventory:

Numerical Applications Inc. Attachment 6 Page 171 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Tube Leakage Transport Group Inventory:

Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Environment Integral Nuclide Release:

Time (h) = 2.0000 Ci kg Atoms Bq I-131 9.1733E+00 7.3994E-08 3.4015E+17 3.3941E+11 Xe-131m 4.9534E-04 5.9137E-12 2.7186E+13 1.8328E+07 Environment Transport Group Inventory:

Present Release Integral Time (h) = 2.0000 Release Rate/s Release Noble gases (atoms) 3.0389E+09 4.2208E+07 2.7186E+13 Elemental I (atoms) 3.1958E+13 4.4386E+11 3.2995E+17 Organic I (atoms) 9.8838E+11 1.3727E+10 1.0205E+16 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Faulted SG Tube Leakage Transport Group Inventory:

Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:

Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Filter Pathway Nuclide Inventory for Control Room Filtered Makeup Time (h) = 2.0000 Ci kg Atoms Bq I-131 3.6202E-05 2.9201E-13 1.3424E+12 1.3395E+06 Control Room Filtered Makeup Transport Group Inventory:

Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 1.3021E+12 Organic I (atoms) 4.0271E+10 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Inleakage Transport Group Inventory:

Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00

Numerical Applications Inc. Attachment 6 Page 172 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Control Room Exhaust Transport Group Inventory:

Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Faulted S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Compartment Atmosphere Nuclide Inventory:

Time (h) = 2.0000 Ci kg Atoms Bq I-131 1.1214E-05 9.0450E-14 4.1581E+11 4.1490E+05 Xe-131m 1.6081E-07 1.9199E-15 8.8258E+09 5.9500E+03 Control Room Transport Group Inventory:

Overlying Time (h) = 2.0000 Atmosphere Sump Pool Noble gases (atoms) 8.8258E+09 0.0000E+00 0.0000E+00 Elemental I (atoms) 4.0333E+11 0.0000E+00 0.0000E+00 Organic I (atoms) 1.2474E+10 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Recirculating Filter Inventory Time (h) = 2.0000 Ci kg Atoms Bq I-131 1.3394E-02 1.0804E-10 4.9666E+14 4.9558E+08 Deposition Recirculating Time (h) = 2.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 4.8176E+14 Organic I (atoms) 0.0000E+00 1.4900E+13 Aerosols (kg) 0.0000E+00 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:

Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Filter Pathway Nuclide Inventory for Control Room Filtered Makeup Time (h) = 2.0000 Ci kg Atoms Bq I-131 3.6202E-05 2.9201E-13 1.3424E+12 1.3395E+06 Control Room Filtered Makeup Transport Group Inventory:

Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00

Numerical Applications Inc. Attachment 6 Page 173 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Elemental I (atoms) 1.3021E+12 Organic I (atoms) 4.0271E+10 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Inleakage Transport Group Inventory:

Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:

Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Total Filter Nuclide Inventory:

Time (h) = 2.0000 Ci kg Atoms Bq I-131 1.3430E-02 1.0833E-10 4.9800E+14 4.9692E+08 Faulted S/G Transport Group Inventory:

Overlying Time (h) = 2.0000 Atmosphere Sump Pool Noble gases (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 2.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Faulted S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Compartment Atmosphere Nuclide Inventory:

Time (h) = 2.0000 Ci kg Atoms Bq I-131 6.2647E+00 5.0532E-08 2.3230E+17 2.3180E+11 Xe-131m 3.3790E-04 4.0341E-12 1.8545E+13 1.2502E+07 Intact S/G Transport Group Inventory:

Overlying Time (h) = 2.0000 Atmosphere Sump Pool Noble gases (atoms) 1.8545E+13 0.0000E+00 0.0000E+00 Elemental I (atoms) 2.2533E+17 0.0000E+00 0.0000E+00 Organic I (atoms) 6.9690E+15 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 2.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00

Numerical Applications Inc. Attachment 6 Page 174 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Intact S/G Tube Leakage Transport Group Inventory:

Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 2.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Detailed model information at time (H) = 8.0000 EAB Doses:

Time (h) = 8.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 9.3663E-06 5.2595E-02 1.5336E-05 1.6106E-03 Accumulated dose (rem) 3.5912E-04 2.0166E+00 5.8802E-04 6.1755E-02 LPZ Doses:

Time (h) = 8.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 5.2653E-07 2.9566E-03 8.6213E-07 9.0542E-05 Accumulated dose (rem) 4.3743E-05 2.4564E-01 7.1624E-05 7.5222E-03 Control Room Doses:

Time (h) = 8.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 4.1994E-08 7.9568E-03 2.3779E-06 2.4229E-04 Accumulated dose (rem) 1.1501E-04 2.1864E+01 6.3753E-03 6.6577E-01 PCS Transport Group Inventory:

Overlying Time (h) = 8.0000 Atmosphere Sump Pool Noble gases (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 8.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Faulted SG Tube Leakage Transport Group Inventory:

Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Tube Leakage Transport Group Inventory:

Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00

Numerical Applications Inc. Attachment 6 Page 175 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Environment Integral Nuclide Release:

Time (h) = 8.0000 Ci kg Atoms Bq I-131 9.2330E+00 7.4475E-08 3.4236E+17 3.4162E+11 Xe-131m 2.0019E-03 2.3900E-11 1.0987E+14 7.4069E+07 Environment Transport Group Inventory:

Present Release Integral Time (h) = 8.0000 Release Rate/s Release Noble gases (atoms) 1.0294E+10 1.4298E+08 1.0987E+14 Elemental I (atoms) 2.9958E+13 4.1608E+11 3.3209E+17 Organic I (atoms) 9.2654E+11 1.2869E+10 1.0271E+16 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Faulted SG Tube Leakage Transport Group Inventory:

Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:

Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Filter Pathway Nuclide Inventory for Control Room Filtered Makeup Time (h) = 8.0000 Ci kg Atoms Bq I-131 1.4371E-04 1.1592E-12 5.3288E+12 5.3172E+06 Control Room Filtered Makeup Transport Group Inventory:

Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 5.1690E+12 Organic I (atoms) 1.5986E+11 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Inleakage Transport Group Inventory:

Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:

Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00

Numerical Applications Inc. Attachment 6 Page 176 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Faulted S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Compartment Atmosphere Nuclide Inventory:

Time (h) = 8.0000 Ci kg Atoms Bq I-131 5.9751E-07 4.8196E-15 2.2156E+10 2.2108E+04 Xe-131m 1.5567E-07 1.8585E-15 8.5435E+09 5.7597E+03 Control Room Transport Group Inventory:

Overlying Time (h) = 8.0000 Atmosphere Sump Pool Noble gases (atoms) 8.5435E+09 0.0000E+00 0.0000E+00 Elemental I (atoms) 2.1491E+10 0.0000E+00 0.0000E+00 Organic I (atoms) 6.6468E+08 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Recirculating Filter Inventory Time (h) = 8.0000 Ci kg Atoms Bq I-131 1.3122E-02 1.0585E-10 4.8658E+14 4.8552E+08 Deposition Recirculating Time (h) = 8.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 4.7198E+14 Organic I (atoms) 0.0000E+00 1.4597E+13 Aerosols (kg) 0.0000E+00 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:

Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Filter Pathway Nuclide Inventory for Control Room Filtered Makeup Time (h) = 8.0000 Ci kg Atoms Bq I-131 1.4371E-04 1.1592E-12 5.3288E+12 5.3172E+06 Control Room Filtered Makeup Transport Group Inventory:

Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 5.1690E+12 Organic I (atoms) 1.5986E+11 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Inleakage Transport Group Inventory:

Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:

Pathway Time (h) = 8.0000 Filter

Numerical Applications Inc. Attachment 6 Page 177 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Total Filter Nuclide Inventory:

Time (h) = 8.0000 Ci kg Atoms Bq I-131 1.3266E-02 1.0701E-10 4.9191E+14 4.9084E+08 Faulted S/G Transport Group Inventory:

Overlying Time (h) = 8.0000 Atmosphere Sump Pool Noble gases (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 8.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Faulted S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Compartment Atmosphere Nuclide Inventory:

Time (h) = 8.0000 Ci kg Atoms Bq I-131 5.8758E+00 4.7395E-08 2.1788E+17 2.1740E+11 Xe-131m 1.2722E-03 1.5189E-11 6.9824E+13 4.7073E+07 Intact S/G Transport Group Inventory:

Overlying Time (h) = 8.0000 Atmosphere Sump Pool Noble gases (atoms) 6.9824E+13 0.0000E+00 0.0000E+00 Elemental I (atoms) 2.1134E+17 0.0000E+00 0.0000E+00 Organic I (atoms) 6.5363E+15 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 8.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Intact S/G Tube Leakage Transport Group Inventory:

Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 8.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00

Numerical Applications Inc. Attachment 6 Page 178 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Aerosols (kg) 0.0000E+00 Detailed model information at time (H) = 12.0000 EAB Doses:

Time (h) = 12.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 1.2031E-11 3.1561E-08 3.1561E-11 9.7290E-10 Accumulated dose (rem) 3.5912E-04 2.0166E+00 5.8802E-04 6.1755E-02 LPZ Doses:

Time (h) = 12.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 4.5537E-13 1.1945E-09 1.1945E-12 3.6822E-11 Accumulated dose (rem) 4.3743E-05 2.4564E-01 7.1624E-05 7.5222E-03 Control Room Doses:

Time (h) = 12.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 9.8208E-10 1.6959E-04 8.7196E-08 5.1641E-06 Accumulated dose (rem) 1.1501E-04 2.1864E+01 6.3754E-03 6.6577E-01 PCS Transport Group Inventory:

Overlying Time (h) = 12.0000 Atmosphere Sump Pool Noble gases (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 12.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Faulted SG Tube Leakage Transport Group Inventory:

Pathway Time (h) = 12.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Tube Leakage Transport Group Inventory:

Pathway Time (h) = 12.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Environment Integral Nuclide Release:

Time (h) = 12.0000 Ci kg Atoms Bq Xe-131m 2.9670E-03 3.5422E-11 1.6284E+14 1.0978E+08 Environment Transport Group Inventory:

Present Release Integral Time (h) = 12.0000 Release Rate/s Release Noble gases (atoms) 3.8690E+08 5.3736E+06 1.6284E+14 Elemental I (atoms) 6.8035E+00 9.4493E-02 3.2736E+17 Organic I (atoms) 2.1042E-01 2.9225E-03 1.0124E+16 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Faulted SG Tube Leakage Transport Group Inventory:

Pathway

Numerical Applications Inc. Attachment 6 Page 179 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Time (h) = 12.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:

Pathway Time (h) = 12.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Filter Pathway Nuclide Inventory for Control Room Filtered Makeup Time (h) = 12.0000 Ci kg Atoms Bq I-131 1.4166E-04 1.1426E-12 5.2528E+12 5.2414E+06 Control Room Filtered Makeup Transport Group Inventory:

Pathway Time (h) = 12.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 5.0952E+12 Organic I (atoms) 1.5758E+11 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Inleakage Transport Group Inventory:

Pathway Time (h) = 12.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:

Pathway Time (h) = 12.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 12.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Faulted S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 12.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Compartment Atmosphere Nuclide Inventory:

Time (h) = 12.0000 Ci kg Atoms Bq Xe-131m 1.5179E-07 1.8122E-15 8.3306E+09 5.6162E+03 Control Room Transport Group Inventory:

Overlying

Numerical Applications Inc. Attachment 6 Page 180 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Time (h) = 12.0000 Atmosphere Sump Pool Noble gases (atoms) 8.3306E+09 0.0000E+00 0.0000E+00 Elemental I (atoms) 1.3643E+02 0.0000E+00 0.0000E+00 Organic I (atoms) 4.2194E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Recirculating Filter Inventory Time (h) = 12.0000 Ci kg Atoms Bq I-131 1.2935E-02 1.0434E-10 4.7965E+14 4.7861E+08 Deposition Recirculating Time (h) = 12.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 4.6526E+14 Organic I (atoms) 0.0000E+00 1.4389E+13 Aerosols (kg) 0.0000E+00 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:

Pathway Time (h) = 12.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Filter Pathway Nuclide Inventory for Control Room Filtered Makeup Time (h) = 12.0000 Ci kg Atoms Bq I-131 1.4166E-04 1.1426E-12 5.2528E+12 5.2414E+06 Control Room Filtered Makeup Transport Group Inventory:

Pathway Time (h) = 12.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 5.0952E+12 Organic I (atoms) 1.5758E+11 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Inleakage Transport Group Inventory:

Pathway Time (h) = 12.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:

Pathway Time (h) = 12.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Total Filter Nuclide Inventory:

Time (h) = 12.0000 Ci kg Atoms Bq I-131 1.3077E-02 1.0548E-10 4.8490E+14 4.8385E+08 Faulted S/G Transport Group Inventory:

Overlying Time (h) = 12.0000 Atmosphere Sump Pool Noble gases (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00

Numerical Applications Inc. Attachment 6 Page 181 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Deposition Recirculating Time (h) = 12.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Faulted S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 12.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Compartment Atmosphere Nuclide Inventory:

Time (h) = 12.0000 Ci kg Atoms Bq I-131 5.7920E+00 4.6719E-08 2.1477E+17 2.1430E+11 Xe-131m 1.8856E-03 2.2511E-11 1.0348E+14 6.9766E+07 Intact S/G Transport Group Inventory:

Overlying Time (h) = 12.0000 Atmosphere Sump Pool Noble gases (atoms) 1.0348E+14 0.0000E+00 0.0000E+00 Elemental I (atoms) 2.0833E+17 0.0000E+00 0.0000E+00 Organic I (atoms) 6.4431E+15 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 12.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Intact S/G Tube Leakage Transport Group Inventory:

Pathway Time (h) = 12.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 12.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Detailed model information at time (H) = 24.0000 EAB Doses:

Time (h) = 24.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 3.2117E-12 2.0034E-16 3.9795E-11 3.2117E-12 Accumulated dose (rem) 3.5912E-04 2.0166E+00 5.8802E-04 6.1755E-02 LPZ Doses:

Time (h) = 24.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 1.2155E-13 7.5826E-18 1.5062E-12 1.2156E-13 Accumulated dose (rem) 4.3743E-05 2.4564E-01 7.1624E-05 7.5222E-03 Control Room Doses:

Time (h) = 24.0000 Whole Body Thyroid Skin TEDE

Numerical Applications Inc. Attachment 6 Page 182 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Delta dose (rem) 2.6202E-10 1.0765E-12 1.0991E-07 2.6206E-10 Accumulated dose (rem) 1.1501E-04 2.1864E+01 6.3755E-03 6.6577E-01 PCS Transport Group Inventory:

Overlying Time (h) = 24.0000 Atmosphere Sump Pool Noble gases (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 24.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Faulted SG Tube Leakage Transport Group Inventory:

Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Tube Leakage Transport Group Inventory:

Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Environment Integral Nuclide Release:

Time (h) = 24.0000 Ci kg Atoms Bq Xe-131m 5.7238E-03 6.8335E-11 3.1414E+14 2.1178E+08 Environment Transport Group Inventory:

Present Release Integral Time (h) = 24.0000 Release Rate/s Release Noble gases (atoms) 3.7058E+08 5.1469E+06 3.1414E+14 Elemental I (atoms) 1.7403E-24 2.4171E-26 3.1354E+17 Organic I (atoms) 5.3824E-26 7.4756E-28 9.6973E+15 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Faulted SG Tube Leakage Transport Group Inventory:

Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:

Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Filter Pathway Nuclide Inventory for Control Room Filtered Makeup Time (h) = 24.0000 Ci kg Atoms Bq I-131 1.3568E-04 1.0944E-12 5.0312E+12 5.0203E+06

Numerical Applications Inc. Attachment 6 Page 183 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Control Room Filtered Makeup Transport Group Inventory:

Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 4.8802E+12 Organic I (atoms) 1.5094E+11 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Inleakage Transport Group Inventory:

Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:

Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Faulted S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Compartment Atmosphere Nuclide Inventory:

Time (h) = 24.0000 Ci kg Atoms Bq Xe-131m 1.4538E-07 1.7357E-15 7.9791E+09 5.3792E+03 Control Room Transport Group Inventory:

Overlying Time (h) = 24.0000 Atmosphere Sump Pool Noble gases (atoms) 7.9791E+09 0.0000E+00 0.0000E+00 Elemental I (atoms) 3.4897E-23 0.0000E+00 0.0000E+00 Organic I (atoms) 1.0793E-24 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Recirculating Filter Inventory Time (h) = 24.0000 Ci kg Atoms Bq I-131 1.2390E-02 9.9936E-11 4.5941E+14 4.5841E+08 Deposition Recirculating Time (h) = 24.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 4.4563E+14 Organic I (atoms) 0.0000E+00 1.3782E+13 Aerosols (kg) 0.0000E+00 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:

Numerical Applications Inc. Attachment 6 Page 184 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Filter Pathway Nuclide Inventory for Control Room Filtered Makeup Time (h) = 24.0000 Ci kg Atoms Bq I-131 1.3568E-04 1.0944E-12 5.0312E+12 5.0203E+06 Control Room Filtered Makeup Transport Group Inventory:

Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 4.8802E+12 Organic I (atoms) 1.5094E+11 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Inleakage Transport Group Inventory:

Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:

Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Total Filter Nuclide Inventory:

Time (h) = 24.0000 Ci kg Atoms Bq I-131 1.2525E-02 1.0103E-10 4.6444E+14 4.6343E+08 Faulted S/G Transport Group Inventory:

Overlying Time (h) = 24.0000 Atmosphere Sump Pool Noble gases (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 24.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Faulted S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Compartment Atmosphere Nuclide Inventory:

Time (h) = 24.0000 Ci kg Atoms Bq

Numerical Applications Inc. Attachment 6 Page 185 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 I-131 5.5476E+00 4.4748E-08 2.0571E+17 2.0526E+11 Xe-131m 3.6375E-03 4.3427E-11 1.9963E+14 1.3459E+08 Intact S/G Transport Group Inventory:

Overlying Time (h) = 24.0000 Atmosphere Sump Pool Noble gases (atoms) 1.9963E+14 0.0000E+00 0.0000E+00 Elemental I (atoms) 1.9954E+17 0.0000E+00 0.0000E+00 Organic I (atoms) 6.1712E+15 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 24.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Intact S/G Tube Leakage Transport Group Inventory:

Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 24.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Detailed model information at time (H) = 96.0000 EAB Doses:

Time (h) = 96.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 1.6616E-11 6.5483E-41 2.0589E-10 1.6616E-11 Accumulated dose (rem) 3.5912E-04 2.0166E+00 5.8802E-04 6.1755E-02 LPZ Doses:

Time (h) = 96.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 2.6728E-13 1.0533E-42 3.3118E-12 2.6728E-13 Accumulated dose (rem) 4.3743E-05 2.4564E-01 7.1624E-05 7.5222E-03 Control Room Doses:

Time (h) = 96.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 8.1339E-10 1.6522E-37 3.4119E-07 8.1339E-10 Accumulated dose (rem) 1.1502E-04 2.1864E+01 6.3758E-03 6.6577E-01 PCS Transport Group Inventory:

Overlying Time (h) = 96.0000 Atmosphere Sump Pool Noble gases (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 96.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00

Numerical Applications Inc. Attachment 6 Page 186 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Faulted SG Tube Leakage Transport Group Inventory:

Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Tube Leakage Transport Group Inventory:

Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Environment Integral Nuclide Release:

Time (h) = 96.0000 Ci kg Atoms Bq Xe-131m 1.8444E-02 2.2020E-10 1.0123E+15 6.8244E+08 Environment Transport Group Inventory:

Present Release Integral Time (h) = 96.0000 Release Rate/s Release Noble gases (atoms) 2.8612E+08 3.9739E+06 1.0123E+15 Elemental I (atoms) 0.0000E+00 0.0000E+00 2.4209E+17 Organic I (atoms) 0.0000E+00 0.0000E+00 7.4873E+15 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Faulted SG Tube Leakage Transport Group Inventory:

Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:

Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Filter Pathway Nuclide Inventory for Control Room Filtered Makeup Time (h) = 96.0000 Ci kg Atoms Bq I-131 1.0476E-04 8.4502E-13 3.8846E+12 3.8762E+06 Control Room Filtered Makeup Transport Group Inventory:

Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 3.7681E+12 Organic I (atoms) 1.1654E+11 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Inleakage Transport Group Inventory:

Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00

Numerical Applications Inc. Attachment 6 Page 187 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Control Room Exhaust Transport Group Inventory:

Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Faulted S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Compartment Atmosphere Nuclide Inventory:

Time (h) = 96.0000 Ci kg Atoms Bq Xe-131m 1.1225E-07 1.3401E-15 6.1607E+09 4.1533E+03 Control Room Transport Group Inventory:

Overlying Time (h) = 96.0000 Atmosphere Sump Pool Noble gases (atoms) 6.1607E+09 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Recirculating Filter Inventory Time (h) = 96.0000 Ci kg Atoms Bq I-131 9.5660E-03 7.7161E-11 3.5471E+14 3.5394E+08 Deposition Recirculating Time (h) = 96.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 3.4407E+14 Organic I (atoms) 0.0000E+00 1.0641E+13 Aerosols (kg) 0.0000E+00 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:

Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Filter Pathway Nuclide Inventory for Control Room Filtered Makeup Time (h) = 96.0000 Ci kg Atoms Bq I-131 1.0476E-04 8.4502E-13 3.8846E+12 3.8762E+06 Control Room Filtered Makeup Transport Group Inventory:

Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 3.7681E+12

Numerical Applications Inc. Attachment 6 Page 188 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Organic I (atoms) 1.1654E+11 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Inleakage Transport Group Inventory:

Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:

Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Total Filter Nuclide Inventory:

Time (h) = 96.0000 Ci kg Atoms Bq I-131 9.6708E-03 7.8006E-11 3.5860E+14 3.5782E+08 Faulted S/G Transport Group Inventory:

Overlying Time (h) = 96.0000 Atmosphere Sump Pool Noble gases (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 96.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Faulted S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Compartment Atmosphere Nuclide Inventory:

Time (h) = 96.0000 Ci kg Atoms Bq I-131 4.2833E+00 3.4550E-08 1.5883E+17 1.5848E+11 Xe-131m 1.1721E-02 1.3993E-10 6.4329E+14 4.3368E+08 Intact S/G Transport Group Inventory:

Overlying Time (h) = 96.0000 Atmosphere Sump Pool Noble gases (atoms) 6.4329E+14 0.0000E+00 0.0000E+00 Elemental I (atoms) 1.5406E+17 0.0000E+00 0.0000E+00 Organic I (atoms) 4.7648E+15 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 96.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00

Numerical Applications Inc. Attachment 6 Page 189 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Intact S/G Tube Leakage Transport Group Inventory:

Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Detailed model information at time (H) = 720.0000 EAB Doses:

Time (h) = 720.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 5.0311E-11 1.8345-188 6.2340E-10 5.0311E-11 Accumulated dose (rem) 3.5912E-04 2.0166E+00 5.8802E-04 6.1755E-02 LPZ Doses:

Time (h) = 720.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 2.3709E-13 8.6448-191 2.9377E-12 2.3709E-13 Accumulated dose (rem) 4.3743E-05 2.4564E-01 7.1624E-05 7.5222E-03 Control Room Doses:

Time (h) = 720.0000 Whole Body Thyroid Skin TEDE Delta dose (rem) 1.6419E-09 3.0858-185 6.8871E-07 1.6419E-09 Accumulated dose (rem) 1.1502E-04 2.1864E+01 6.3765E-03 6.6577E-01 PCS Transport Group Inventory:

Overlying Time (h) = 720.0000 Atmosphere Sump Pool Noble gases (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 720.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Faulted SG Tube Leakage Transport Group Inventory:

Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Tube Leakage Transport Group Inventory:

Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Environment Integral Nuclide Release:

Numerical Applications Inc. Attachment 6 Page 190 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Time (h) = 720.0000 Ci kg Atoms Bq Xe-131m 2.1766E-02 2.5985E-10 1.1946E+15 8.0532E+08 Environment Transport Group Inventory:

Present Release Integral Time (h) = 720.0000 Release Rate/s Release Noble gases (atoms) 3.0414E+07 4.2242E+05 1.1946E+15 Elemental I (atoms) 0.0000E+00 0.0000E+00 2.5733E+16 Organic I (atoms) 0.0000E+00 0.0000E+00 7.9587E+14 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Faulted SG Tube Leakage Transport Group Inventory:

Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:

Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Filter Pathway Nuclide Inventory for Control Room Filtered Makeup Time (h) = 720.0000 Ci kg Atoms Bq I-131 1.1136E-05 8.9823E-14 4.1292E+11 4.1202E+05 Control Room Filtered Makeup Transport Group Inventory:

Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 4.0053E+11 Organic I (atoms) 1.2388E+10 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Inleakage Transport Group Inventory:

Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:

Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Faulted S/G Steam Release Transport Group Inventory:

Numerical Applications Inc. Attachment 6 Page 191 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Compartment Atmosphere Nuclide Inventory:

Time (h) = 720.0000 Ci kg Atoms Bq Xe-131m 1.1932E-08 1.4245E-16 6.5486E+08 4.4148E+02 Control Room Transport Group Inventory:

Overlying Time (h) = 720.0000 Atmosphere Sump Pool Noble gases (atoms) 6.5486E+08 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Recirculating Filter Inventory Time (h) = 720.0000 Ci kg Atoms Bq I-131 1.0168E-03 8.2020E-12 3.7705E+13 3.7623E+07 Deposition Recirculating Time (h) = 720.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 3.6574E+13 Organic I (atoms) 0.0000E+00 1.1311E+12 Aerosols (kg) 0.0000E+00 0.0000E+00 Control Room Unfiltered Makeup Transport Group Inventory:

Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Filter Pathway Nuclide Inventory for Control Room Filtered Makeup Time (h) = 720.0000 Ci kg Atoms Bq I-131 1.1136E-05 8.9823E-14 4.1292E+11 4.1202E+05 Control Room Filtered Makeup Transport Group Inventory:

Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 4.0053E+11 Organic I (atoms) 1.2388E+10 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Inleakage Transport Group Inventory:

Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust Transport Group Inventory:

Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00

Numerical Applications Inc. Attachment 6 Page 192 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Aerosols (kg) 0.0000E+00 Control Room Total Filter Nuclide Inventory:

Time (h) = 720.0000 Ci kg Atoms Bq I-131 1.0280E-03 8.2918E-12 3.8118E+13 3.8035E+07 Faulted S/G Transport Group Inventory:

Overlying Time (h) = 720.0000 Atmosphere Sump Pool Noble gases (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 720.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Faulted S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Compartment Atmosphere Nuclide Inventory:

Time (h) = 720.0000 Ci kg Atoms Bq I-131 4.5530E-01 3.6725E-09 1.6883E+16 1.6846E+10 Xe-131m 1.3832E-02 1.6513E-10 7.5911E+14 5.1177E+08 Intact S/G Transport Group Inventory:

Overlying Time (h) = 720.0000 Atmosphere Sump Pool Noble gases (atoms) 7.5911E+14 0.0000E+00 0.0000E+00 Elemental I (atoms) 1.6376E+16 0.0000E+00 0.0000E+00 Organic I (atoms) 5.0649E+14 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 720.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Intact S/G Tube Leakage Transport Group Inventory:

Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Intact S/G Steam Release Transport Group Inventory:

Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00

Numerical Applications Inc. Attachment 6 Page 193 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Transport Group Totals in Model:

Noble Gases (atoms) 1.9537E+15 Elemental I (atoms) 4.2147E+16 Organic I (atoms) 1.3035E+15 Aerosols (kg) 0.0000E+00 36004 I-131 Summary PCS Environment Control Room Time (hr) I-131 (Curies) I-131 (Curies) I-131 (Curies) 0.001 0.0000E+00 3.9708E-01 1.6266E-03 0.001 0.0000E+00 8.3823E-01 5.0594E-03 0.280 0.0000E+00 9.1376E+00 2.8804E-02 0.333 0.0000E+00 9.1398E+00 2.7167E-02 0.600 0.0000E+00 9.1529E+00 7.7182E-03 0.860 0.0000E+00 9.1588E+00 2.2636E-03 1.120 0.0000E+00 9.1627E+00 6.6424E-04 1.380 0.0000E+00 9.1661E+00 1.9531E-04 1.640 0.0000E+00 9.1692E+00 5.7821E-05 1.900 0.0000E+00 9.1722E+00 1.7505E-05 2.000 0.0000E+00 9.1733E+00 1.1214E-05 2.260 0.0000E+00 9.1763E+00 3.7364E-06 2.520 0.0000E+00 9.1792E+00 1.5428E-06 2.780 0.0000E+00 9.1821E+00 8.9837E-07 3.040 0.0000E+00 9.1850E+00 7.0819E-07 3.300 0.0000E+00 9.1878E+00 6.5120E-07 3.560 0.0000E+00 9.1906E+00 6.3326E-07 3.820 0.0000E+00 9.1933E+00 6.2677E-07 4.080 0.0000E+00 9.1960E+00 6.2364E-07 4.340 0.0000E+00 9.1987E+00 6.2151E-07 4.600 0.0000E+00 9.2014E+00 6.1966E-07 4.860 0.0000E+00 9.2040E+00 6.1791E-07 5.120 0.0000E+00 9.2066E+00 6.1618E-07 5.380 0.0000E+00 9.2091E+00 6.1447E-07 5.640 0.0000E+00 9.2116E+00 6.1277E-07 5.900 0.0000E+00 9.2141E+00 6.1107E-07 6.160 0.0000E+00 9.2166E+00 6.0937E-07 6.420 0.0000E+00 9.2190E+00 6.0768E-07 6.680 0.0000E+00 9.2214E+00 6.0600E-07 6.940 0.0000E+00 9.2237E+00 6.0432E-07 7.200 0.0000E+00 9.2261E+00 6.0264E-07 7.460 0.0000E+00 9.2283E+00 6.0097E-07 7.720 0.0000E+00 9.2306E+00 5.9930E-07 7.980 0.0000E+00 9.2328E+00 5.9764E-07 8.000 0.0000E+00 9.2330E+00 5.9751E-07 8.260 0.0000E+00 9.2244E+00 1.7519E-07 8.520 0.0000E+00 9.2158E+00 5.1368E-08 8.780 0.0000E+00 9.2072E+00 1.5061E-08 9.040 0.0000E+00 9.1986E+00 4.4160E-09 9.300 0.0000E+00 9.1900E+00 1.2948E-09 9.560 0.0000E+00 9.1814E+00 3.7964E-10 9.820 0.0000E+00 9.1728E+00 1.1131E-10 10.080 0.0000E+00 9.1643E+00 3.2637E-11 12.000 0.0000E+00 9.1013E+00 3.7930E-15 24.000 0.0000E+00 8.7173E+00 9.7023E-40 96.000 0.0000E+00 6.7306E+00 2.7181-187 720.000 0.0000E+00 7.1545E-01 0.0000E+00 Faulted S/G Intact S/G Time (hr) I-131 (Curies) I-131 (Curies) 0.001 4.9124E+00 3.5555E+00 0.001 8.3196E+00 6.4000E+00 0.280 2.6599E-34 6.3809E+00 0.333 6.8377E-41 6.3773E+00 0.600 7.2515E-74 6.3591E+00 0.860 5.1800-106 6.3415E+00 1.120 3.7003-138 6.3239E+00

Numerical Applications Inc. Attachment 6 Page 194 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 1.380 2.6432-170 6.3064E+00 1.640 1.8882-202 6.2889E+00 1.900 1.3488-234 6.2714E+00 2.000 5.8352-247 6.2647E+00 2.260 4.1683-279 6.2474E+00 2.520 2.9775-311 6.2300E+00 2.780 0.0000E+00 6.2128E+00 3.040 0.0000E+00 6.1955E+00 3.300 0.0000E+00 6.1783E+00 3.560 0.0000E+00 6.1612E+00 3.820 0.0000E+00 6.1441E+00 4.080 0.0000E+00 6.1271E+00 4.340 0.0000E+00 6.1101E+00 4.600 0.0000E+00 6.0931E+00 4.860 0.0000E+00 6.0762E+00 5.120 0.0000E+00 6.0594E+00 5.380 0.0000E+00 6.0426E+00 5.640 0.0000E+00 6.0258E+00 5.900 0.0000E+00 6.0091E+00 6.160 0.0000E+00 5.9924E+00 6.420 0.0000E+00 5.9758E+00 6.680 0.0000E+00 5.9592E+00 6.940 0.0000E+00 5.9427E+00 7.200 0.0000E+00 5.9262E+00 7.460 0.0000E+00 5.9098E+00 7.720 0.0000E+00 5.8934E+00 7.980 0.0000E+00 5.8771E+00 8.000 0.0000E+00 5.8758E+00 8.260 0.0000E+00 5.8703E+00 8.520 0.0000E+00 5.8648E+00 8.780 0.0000E+00 5.8594E+00 9.040 0.0000E+00 5.8539E+00 9.300 0.0000E+00 5.8484E+00 9.560 0.0000E+00 5.8430E+00 9.820 0.0000E+00 5.8375E+00 10.080 0.0000E+00 5.8321E+00 12.000 0.0000E+00 5.7920E+00 24.000 0.0000E+00 5.5476E+00 96.000 0.0000E+00 4.2833E+00 720.000 0.0000E+00 4.5530E-01 Cumulative Dose Summary EAB LPZ Control Room Time Thyroid TEDE Thyroid TEDE Thyroid TEDE (hr) (rem) (rem) (rem) (rem) (rem) (rem) 0.001 8.0933E-02 2.4784E-03 1.0000E-02 3.0624E-04 6.0467E-04 1.8412E-05 0.001 2.5178E-01 7.7103E-03 3.1110E-02 9.5270E-04 2.5930E-03 7.8958E-05 0.280 1.9452E+00 5.9568E-02 2.4035E-01 7.3604E-03 1.2151E+01 3.7001E-01 0.333 1.9460E+00 5.9593E-02 2.4045E-01 7.3635E-03 1.4147E+01 4.3078E-01 0.600 1.9505E+00 5.9730E-02 2.4100E-01 7.3803E-03 1.9667E+01 5.9887E-01 0.860 1.9534E+00 5.9820E-02 2.4137E-01 7.3915E-03 2.1215E+01 6.4602E-01 1.120 1.9560E+00 5.9898E-02 2.4168E-01 7.4011E-03 2.1670E+01 6.5985E-01 1.380 1.9584E+00 5.9972E-02 2.4198E-01 7.4102E-03 2.1803E+01 6.6391E-01 1.640 1.9608E+00 6.0045E-02 2.4227E-01 7.4193E-03 2.1842E+01 6.6511E-01 1.900 1.9631E+00 6.0117E-02 2.4257E-01 7.4282E-03 2.1854E+01 6.6547E-01 2.000 1.9640E+00 6.0145E-02 2.4268E-01 7.4316E-03 2.1856E+01 6.6552E-01 2.260 1.9664E+00 6.0217E-02 2.4281E-01 7.4357E-03 2.1858E+01 6.6559E-01 2.520 1.9687E+00 6.0289E-02 2.4294E-01 7.4397E-03 2.1859E+01 6.6562E-01 2.780 1.9711E+00 6.0360E-02 2.4307E-01 7.4437E-03 2.1860E+01 6.6563E-01 3.040 1.9734E+00 6.0431E-02 2.4320E-01 7.4477E-03 2.1860E+01 6.6564E-01 3.300 1.9757E+00 6.0503E-02 2.4334E-01 7.4517E-03 2.1860E+01 6.6565E-01 3.560 1.9780E+00 6.0574E-02 2.4347E-01 7.4557E-03 2.1860E+01 6.6565E-01 3.820 1.9803E+00 6.0644E-02 2.4360E-01 7.4597E-03 2.1860E+01 6.6566E-01 4.080 1.9826E+00 6.0715E-02 2.4373E-01 7.4637E-03 2.1861E+01 6.6567E-01 4.340 1.9849E+00 6.0785E-02 2.4385E-01 7.4676E-03 2.1861E+01 6.6567E-01 4.600 1.9872E+00 6.0855E-02 2.4398E-01 7.4716E-03 2.1861E+01 6.6568E-01 4.860 1.9895E+00 6.0925E-02 2.4411E-01 7.4755E-03 2.1861E+01 6.6569E-01 5.120 1.9918E+00 6.0995E-02 2.4424E-01 7.4794E-03 2.1862E+01 6.6569E-01 5.380 1.9941E+00 6.1065E-02 2.4437E-01 7.4833E-03 2.1862E+01 6.6570E-01 5.640 1.9963E+00 6.1134E-02 2.4450E-01 7.4872E-03 2.1862E+01 6.6571E-01

Numerical Applications Inc. Attachment 6 Page 195 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 5.900 1.9986E+00 6.1203E-02 2.4462E-01 7.4911E-03 2.1862E+01 6.6571E-01 6.160 2.0008E+00 6.1272E-02 2.4475E-01 7.4950E-03 2.1862E+01 6.6572E-01 6.420 2.0031E+00 6.1341E-02 2.4488E-01 7.4989E-03 2.1863E+01 6.6573E-01 6.680 2.0053E+00 6.1410E-02 2.4500E-01 7.5027E-03 2.1863E+01 6.6573E-01 6.940 2.0076E+00 6.1478E-02 2.4513E-01 7.5066E-03 2.1863E+01 6.6574E-01 7.200 2.0098E+00 6.1547E-02 2.4525E-01 7.5104E-03 2.1863E+01 6.6575E-01 7.460 2.0120E+00 6.1615E-02 2.4538E-01 7.5142E-03 2.1863E+01 6.6575E-01 7.720 2.0142E+00 6.1683E-02 2.4550E-01 7.5181E-03 2.1864E+01 6.6576E-01 7.980 2.0164E+00 6.1750E-02 2.4563E-01 7.5219E-03 2.1864E+01 6.6577E-01 8.000 2.0166E+00 6.1755E-02 2.4564E-01 7.5222E-03 2.1864E+01 6.6577E-01 8.260 2.0166E+00 6.1755E-02 2.4564E-01 7.5222E-03 2.1864E+01 6.6577E-01 8.520 2.0166E+00 6.1755E-02 2.4564E-01 7.5222E-03 2.1864E+01 6.6577E-01 8.780 2.0166E+00 6.1755E-02 2.4564E-01 7.5222E-03 2.1864E+01 6.6577E-01 9.040 2.0166E+00 6.1755E-02 2.4564E-01 7.5222E-03 2.1864E+01 6.6577E-01 9.300 2.0166E+00 6.1755E-02 2.4564E-01 7.5222E-03 2.1864E+01 6.6577E-01 9.560 2.0166E+00 6.1755E-02 2.4564E-01 7.5222E-03 2.1864E+01 6.6577E-01 9.820 2.0166E+00 6.1755E-02 2.4564E-01 7.5222E-03 2.1864E+01 6.6577E-01 10.080 2.0166E+00 6.1755E-02 2.4564E-01 7.5222E-03 2.1864E+01 6.6577E-01 12.000 2.0166E+00 6.1755E-02 2.4564E-01 7.5222E-03 2.1864E+01 6.6577E-01 24.000 2.0166E+00 6.1755E-02 2.4564E-01 7.5222E-03 2.1864E+01 6.6577E-01 96.000 2.0166E+00 6.1755E-02 2.4564E-01 7.5222E-03 2.1864E+01 6.6577E-01 720.000 2.0166E+00 6.1755E-02 2.4564E-01 7.5222E-03 2.1864E+01 6.6577E-01 Worst Two-Hour Dose (Provided for Dose Location 1)

EAB Time Whole Body Thyroid Skin TEDE (hr) (rem) (rem) (rem) (rem) 0.0 3.3534E-04 1.8831E+00 5.4908E-04 5.7666E-02 30 Day Control Room Skin Dose Control Room Time Skin (hr) (rem) 720.0 6.3765E-03

Numerical Applications Inc. Attachment 7 Page 196 of 196 Palisades Design Basis Main Steam Line Break AST Radiological Analysis Calculation Number: NAI-1131-018 Rev. 1 Verification Comments for Calculation NAI-1149-018 Rev. 1 Comment 1 Page 12 - The last assumption makes reference to actions that will be taken prior to the end of Palisades refueling outage 19 and to scheduled testing. There is no statement in the purpose of this calculation that limits its applicability to a specific time frame. If this calculation is to become the analysis of record for the MSLB dose, it should not contain references to time-dependent plant conditions.

Response

Once NRC approval is received for the alternate source term calculations, formal incorporation into the design and licensing basis will occur. However, prior to formal incorporation, plant modifications are required. The statements in Section 4 are meant to indicate that the calculation is not applicable to Palisades until after the required modifications are implemented.

Beyond the initial limitation of applicability to time periods post-modification, no additional restriction to specific time frames is intended. The text has been changed for clarification.