IR 05000607/2006201

From kanterella
(Redirected from ML062350244)
Jump to navigation Jump to search
IR 05000607-06-201, 07/31-08/03/2006, University of California - Davis, Mcclellan Nuclear Radiation Center, Review of Selected Aspects of the Licensee'S 2 Megawatt Class I Research and Test Reactor Safety Programs Including: Organizational
ML062350244
Person / Time
Site: University of California-Davis
Issue date: 08/23/2006
From: Johnny Eads
NRC/NRR/ADRA/DPR/PRTB
To: Flocchini R
McClellan Nuclear Research Center
Bassett C, NRR/DRIP/REXB, 404-562-4899
References
IR-06-201
Download: ML062350244 (20)


Text

ust 23, 2006

SUBJECT:

NRC INSPECTION REPORT NO. 50-607/2006-201

Dear Dr. Flocchini:

On July 31 - August 3, 2006, the U.S. Nuclear Regulatory Commission (NRC) conducted an inspection at your University of California-Davis McClellan Nuclear Radiation Center. The enclosed report documents the inspection results, which were discussed on August 3, 2006, with W. Steingass, Reactor Supervisor, and other members of your staff.

The inspection examined activities conducted under your license as they relate to safety and compliance with the NRCs rules and regulations and with the conditions of your license. The inspector reviewed selected procedures and records, observed activities, and interviewed personnel. Based on the results of this inspection, no findings of significance were identified.

In accordance with Section 2.390, Public inspections, exemptions, and requests for withholding, of Title 10 of the Code of Federal Regulations (CFR), a copy of this letter, its enclosure, and your response (if any) will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records component of NRCs Agencywide Documents Access and Management System (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).

Should you have any questions concerning this inspection, please contact Craig Bassett at 404-358-6515.

Sincerely,

/RA/

Johnny H. Eads, Branch Chief Research and Test Reactors Branch B Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket No. 50-607 License No. R-130 Enclosure: NRC Inspection Report No. 50-607/2006-201 cc w/enclosure: See next page

University of California - Davis/McClellan MNRC Docket No. 50-607 cc:

Mr. Jeff Ching 5335 Price Avenue, Bldg. 258 McClellan AFB, CA 95652-2504 Test, Research, and Training Reactor Newsletter University of Florida 202 Nuclear Sciences Center Gainesville, FL 32611

August 23, 2006 Dr. Robert