Letter Sequence RAI |
---|
|
Initiation
- Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request
- Acceptance...
Results
Other: ML20338A261, ML20338A262, ML21250A366, ML21252A757, ML22041A377, ML22041A378, ML22154A543, ML22172A198, ML22174A293, ML22213A162, ML22213A169, ML22214B829, ML22291A295
|
MONTHYEARML20188A3382020-07-0606 July 2020 UC Davis Mcclellan Nuclear Research Center 2019 Annual Report Project stage: Request ML20338A2612020-12-10010 December 2020 NRR-106 University of California Davis License Renewal - Audit Questions Project stage: Other ML20338A2622020-12-10010 December 2020 NRR-106 University of California Davis License Renewal - Regulatory Audit Letter and Plan Project stage: Other ML20338A2572020-12-10010 December 2020 University of California Davis License Renewal Regulatory Audit - Plan and Questions Project stage: Request ML21265A5402021-06-24024 June 2021, 22 September 2021, 23 September 2021, 24 September 2021 University of California-Davis - Letter for Response to Request for Supplemental Information Project stage: Request ML21250A3662021-09-14014 September 2021 Regents of the University of California Report on the Regulatory Audit License Renewal Application for the University of California Davis/Mcclellan Nuclear Research Center Triga Nuclear Reactor Project stage: Other ML21269A0012021-09-30030 September 2021 University of California - Davis/Mccellan Nuclear Research Center Reactor Selection and Training Plan for Reactor Personnel Project stage: Request ML21252A7572021-10-0505 October 2021 University of California-Davis/MCCLELLAN - Approval of the Revised Nuclear Radiation Center Selection and Training Plan Project stage: Other ML21316A1162021-11-30030 November 2021 Regents of the University of California - Request for Additional Information Regarding License Renewal Application for the University of California-Davis Mccellan Nuclear Research Center Project stage: RAI ML21351A3172021-12-17017 December 2021 UC Davis MNRC Response to NRC Staff Request for Additional Information Regarding Licensing Renewal Application Letter Issued November 30th, 2021 Project stage: Request ML22014A1272022-01-11011 January 2022 50 .54P Submittal of the Ucd/Mnrc Physical Security Plan for University of California, Davis Mcclellan Nuclear Research Center (Ucd/Mnrc), Docket No. 50-607, Facility Operating License No. R-130 the Project stage: Request ML22038A1402022-02-0808 February 2022 Regents of the University of California - Request for Additional Information Regarding License Renewal Application for the University of California - Davis/Mcclellan Nuclear Research Center Project stage: RAI ML22041A3792022-02-28028 February 2022, 3 March 2022 Ucd Letter and FRN for Docketing and Opportunity for Hearing for the License Renewal Application of the Ucd Mcclellan Nuclear Research Center Project stage: Request ML22041A3782022-02-28028 February 2022 Regents of the University of California - Determination of Acceptability and Sufficiency for Docketing and Opportunity for Hearing Regarding the License Renewal Application for the University of California - Davis/Mcclellan Nuclear Research Project stage: Other ML22041A3772022-03-0303 March 2022 License Renewal Application; Docketing; Opportunity to Request a Hearing and Petition for Leave to Intervene; Order Imposing Procedures University of California Davis (FRN) Project stage: Other ML22089A1582022-03-30030 March 2022 UC Davis MNRC Response to NRC Staff Request for Additional Information Regarding Licensing Renewal Application Letter Issued February 8th, 2022 Project stage: Request ML22109A1042022-05-0303 May 2022 Regents of the Univ. of CA - Review of the Physical Security Plan in Support of License Renewal Application for the Univ. of CA-Davis/McCellan Nuclear Research Center Project stage: Approval ML22154A5422022-06-0303 June 2022 Univ. of CA - Davis, MNRC Submittal of Technical Specification in Support of License Renewal Application Project stage: Request ML22146A1942022-06-0303 June 2022 Regents of the University of California - RAI Regarding License Renewal Application for the University of California - Davis/Mccellan Nuclear Research Center Project stage: RAI ML22154A5432022-06-0303 June 2022 Univ. of CA - Davis, MNRC Technical Specification in Support of License Renewal Application Project stage: Other ML22172A1992022-06-21021 June 2022 Technical Specifications for the University of California - Davis Mcclellan Nuclear Radiation Center (Ucd/Mnrc) Project stage: Request ML22172A1982022-06-21021 June 2022 UC Davis MNRC Submission of Technical Specification in Support of License Renewal Application Project stage: Other ML22172A1972022-06-21021 June 2022 UC Davis MNRC Submission of Technical Specification in Support of License Renewal Application Project stage: Request ML22173A2012022-06-21021 June 2022, 22 June 2022, 30 June 2022 Response to NRC Request for Additional Information Letter Dated June 3rd 2022 Regarding License Renew Al Application for the University of California - Davis/Mcclellan Nuclear Research Center Project stage: Request ML22174A2932022-06-28028 June 2022 Regents of the University of California - Report on the Regulatory Audit License Renewal Application for the University of California - Davis/Mcclellan Project stage: Other ML22181B0822022-06-30030 June 2022 University of California-Davis/McClellan Nuclear Research Center, Response to NRC Request for Additional Information Letter Dated June 24th, 2022 Regarding License Renewal Application Project stage: Response to RAI ML22213A1692022-10-18018 October 2022 Regents of the University of California - Environmental Assessment and Finding of No Significant Impact Regarding Renewal of Facility Operating License No. R-130 for the University of California - Davis/Mcclellan Nuclear Research Center Project stage: Other ML22213A1622022-10-18018 October 2022 FRN Re UCD-MNRC Environment Assessment Project stage: Other ML22213A1632022-10-18018 October 2022 Ucd License Renewal Environmental Assessment FRN Pkg Project stage: Request ML22214B8302022-11-21021 November 2022 FRN - Issuance of Renewed Facility Operating License No. R-130 Project stage: Approval ML22214B8292022-11-21021 November 2022 Letter to Ucd with Renewed Facility Operating License Project stage: Other ML22214B8312022-11-21021 November 2022 NRC Safety Evaluation for UC Davis 7.5.22 Project stage: Approval ML22214B8282022-11-21021 November 2022 University of California Davis License Renewal Issuance Package Project stage: Request ML22291A2952022-11-21021 November 2022 Proposed MNRC Tech Specs 10182022 Project stage: Other 2022-10-18
[Table View] |
|
---|
Category:Letter
MONTHYEARML24169A3302024-06-17017 June 2024 UC Davis MNRC Change in Address of Level 1 Management ML24143A1422024-05-22022 May 2024 University of California-Davis Mcclellan Nuclear Research Center - 2023 Annual Report (Cover Letter) ML24094A0682024-04-0404 April 2024 University of California-Davis Mcclellan - Change of Facility Backup Project Manager IR 05000607/20242012024-03-28028 March 2024 University of California-Davis - U.S. Nuclear Regulatory Commission Routine Inspection Report No. 05000607/2024201 ML24032A1352024-02-0101 February 2024 Examination Confirmation Letter No. 50-607/OL-24-01, University of California-Davis ML23332A7062023-11-27027 November 2023 University of California, Davis Mcclellan Nuclear Research Center (MNRC) License Holder Appointment ML23263A9762023-09-22022 September 2023 Regents of the Ucd Issuance of Amendment No. 10 to Renewed Facility Operating License R-130 ML23262B5202023-09-19019 September 2023 University of California Davis Mcclellan Nuclear Research Center (Mnrc), Docket Number 50-607, License Number R-130, Supplement to License Amendment Request 2023-02 ML23258A2422023-09-15015 September 2023 University of California Davis Mcclellan Nuclear Research Center (Mnrc), Docket Number 50-607, License Number R-130, License Amendment Request 2023-02 ML23222A1872023-08-10010 August 2023 Univ. of California, Davis, 14-Day Written Follow-up to Call Made to the HOO (EM 56643) on July 28th 2023 ML23095A0652023-03-14014 March 2023 American Nuclear Insurers, Notice of Cancellation Rescinded ML23045A0452023-03-0202 March 2023 Regents of the University of California - Issuance of Amendment No. 9 to Renewed Facility Operating License No. R-130 to Amend the Technical Specifications for the University of California - Davis/Mcclellan Nuclear Research Center ML23073A3992023-03-0101 March 2023 University of California Davis Mcclellan Nuclear Research Center (MNRC) License Holder Appointment IR 05000607/20232012023-02-23023 February 2023 University of California - Davis – U.S. Nuclear Regulatory Commission Routine Inspection Report 05000607/2023201 ML23045A3202023-02-14014 February 2023 14 Day Notification to Document Control Desk of Event 56331 Made to NRC Operations Center by UC Davis MNRC on February 1st at 1651 Est ML23039A2072023-02-0808 February 2023 University of California Davis Mcclellan Nuclear Research Center (Mnrc), Docket Number 50-607, License Number R-130, License Amendment Request 2023-01 IR 05000607/20222022022-12-28028 December 2022 University of California-Davis - Us Nuclear Regulatory Commission Routine Inspection Report No. 05000607/2022202 ML22214B8292022-11-21021 November 2022 Letter to Ucd with Renewed Facility Operating License ML22213A1622022-10-18018 October 2022 FRN Re UCD-MNRC Environment Assessment ML22213A1692022-10-18018 October 2022 Regents of the University of California - Environmental Assessment and Finding of No Significant Impact Regarding Renewal of Facility Operating License No. R-130 for the University of California - Davis/Mcclellan Nuclear Research Center ML22193A2532022-07-12012 July 2022 Univ. of California-Davis - Summary of the Analysis of Changes Made to the MNRC Emergency Plan Under the Provisions of 10 CFR 50.54q ML22181B0822022-06-30030 June 2022 University of California-Davis/McClellan Nuclear Research Center, Response to NRC Request for Additional Information Letter Dated June 24th, 2022 Regarding License Renewal Application ML22174A2932022-06-28028 June 2022 Regents of the University of California - Report on the Regulatory Audit License Renewal Application for the University of California - Davis/Mcclellan ML22173A2092022-06-24024 June 2022 Regents of the University of California; Request for Additional Information Regarding License Renewal Application for the University of California ML22174A4222022-06-23023 June 2022 Additional Response to NRC Request for Additional Information Letter Dated June 3rd 2022 Regarding License Renewal Application for the University of California-Davis/McClellan Nuclear Research Center ML22173A2022022-06-22022 June 2022 Response to NRC Request for Additional Information Letter Dated June 3rd 2022 Regarding License Renew Al Application for the University of California - Davis/Mcclellan Nuclear Research Center ML22172A1982022-06-21021 June 2022 UC Davis MNRC Submission of Technical Specification in Support of License Renewal Application ML22154A5442022-06-0303 June 2022 Univ. of CA - Davis, MNRC Submittal of Technical Specification in Support of License Renewal Application ML22146A1942022-06-0303 June 2022 Regents of the University of California - RAI Regarding License Renewal Application for the University of California - Davis/Mccellan Nuclear Research Center ML22154A5482022-06-0303 June 2022 University of California - Davis, Submittal of MNRC 2021 Annual Report ML22137A2602022-05-26026 May 2022 University of California - Davis - Closure of Confirmatory Action Letter No. NRR 02 002 on the Site-Specific Compensatory Measures Implementation Plan IR 05000607/20222012022-05-26026 May 2022 University of California-Davis U.S. Nuclear Regulatory Commission Routine Inspection Report No 05000607/2022201 ML23142A3032022-05-22022 May 2022 Univ. of California - Davis, Submittal of MNRC 2022 Annual Report ML22109A1042022-05-0303 May 2022 Regents of the Univ. of CA - Review of the Physical Security Plan in Support of License Renewal Application for the Univ. of CA-Davis/McCellan Nuclear Research Center ML22089A1582022-03-30030 March 2022 UC Davis MNRC Response to NRC Staff Request for Additional Information Regarding Licensing Renewal Application Letter Issued February 8th, 2022 ML22041A3782022-02-28028 February 2022 Regents of the University of California - Determination of Acceptability and Sufficiency for Docketing and Opportunity for Hearing Regarding the License Renewal Application for the University of California - Davis/Mcclellan Nuclear Research ML22038A1402022-02-0808 February 2022 Regents of the University of California - Request for Additional Information Regarding License Renewal Application for the University of California - Davis/Mcclellan Nuclear Research Center ML22026A2862022-02-0202 February 2022 Regents of the University of California - Regulatory Audit Re License Renewal Application for the University of California - Davis/Mcclellan Nuclear Research Center Training, Research, Isotope, General Atomics Nuclear Reactor ML22014A1272022-01-11011 January 2022 50 .54P Submittal of the Ucd/Mnrc Physical Security Plan for University of California, Davis Mcclellan Nuclear Research Center (Ucd/Mnrc), Docket No. 50-607, Facility Operating License No. R-130 the ML21300A3922021-12-23023 December 2021 University of California-Davis U.S. Nuclear Regulatory Commission Routine Inspection Report No. 05000607/2021202 ML21351A3172021-12-17017 December 2021 UC Davis MNRC Response to NRC Staff Request for Additional Information Regarding Licensing Renewal Application Letter Issued November 30th, 2021 IR 05000607/20212022021-12-0606 December 2021 University of California-Davis - Nuclear Regulatory Commission Security Inspection Report No. 05000607/2021202 Cover Letter ML21316A1162021-11-30030 November 2021 Regents of the University of California - Request for Additional Information Regarding License Renewal Application for the University of California-Davis Mccellan Nuclear Research Center ML21252A7572021-10-0505 October 2021 University of California-Davis/MCCLELLAN - Approval of the Revised Nuclear Radiation Center Selection and Training Plan ML21265A5412021-09-22022 September 2021 UC Davis MNRC Cover Letter for Response to Request for Supplemental Information ML21250A3662021-09-14014 September 2021 Regents of the University of California Report on the Regulatory Audit License Renewal Application for the University of California Davis/Mcclellan Nuclear Research Center Triga Nuclear Reactor ML21175A3342021-06-22022 June 2021 Transmittal of University of California, Davis, MNRC 2020 Annual Report IR 05000607/20212012021-05-0707 May 2021 University of California-Davis - U. S. Nuclear Regulatory Commission Routine Inspection Report No. 05000607/2021201 ML21029A1472021-01-25025 January 2021 UC Davis Mcclellan Nuclear Research Center - 50.54P Submittal of the Ucd/Mnrc Physical Security Plan ML20338A2622020-12-10010 December 2020 NRR-106 University of California Davis License Renewal - Regulatory Audit Letter and Plan 2024-06-17
[Table view] Category:Request for Additional Information (RAI)
MONTHYEARML22173A2092022-06-24024 June 2022 Regents of the University of California; Request for Additional Information Regarding License Renewal Application for the University of California ML22146A1942022-06-0303 June 2022 Regents of the University of California - RAI Regarding License Renewal Application for the University of California - Davis/Mccellan Nuclear Research Center ML22038A1402022-02-0808 February 2022 Regents of the University of California - Request for Additional Information Regarding License Renewal Application for the University of California - Davis/Mcclellan Nuclear Research Center ML21316A1162021-11-30030 November 2021 Regents of the University of California - Request for Additional Information Regarding License Renewal Application for the University of California-Davis Mccellan Nuclear Research Center ML20057D6442020-04-20020 April 2020 University of California Davis - Request for a Section 106 Review Under the National Preservation Act for the Proposed Renewal of Facility Operating License No. R-130 for the Mcclellan Nuclear Research Center Training, Isotopes General Atom ML0527105032005-10-0707 October 2005 RAI Letter - Security Measures - Sternglass 2022-06-03
[Table view] |
Text
P. Mohapatra Dr. Prasant Mohapatra Vice Chancellor for Research Department of Computer Science University of California Davis, CA 95616
SUBJECT:
REGENTS OF THE UNIVERSITY OF CALIFORNIA - REQUEST FOR ADDITIONAL INFORMATION REGARDING LICENSE RENEWAL APPLICATION FOR THE UNIVERSITY OF CALIFORNIA - DAVIS/MCCLELLAN NUCLEAR RESEARCH CENTER (EPID NO. L-2020-NFR-0002)
Dear Dr. Mohapatra:
By letter dated June 11, 2018 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML18179A501), the Regents of the University of California submitted a license renewal application (LRA) for a 20-year renewal of the Class 104c Facility Operating License No. R-130, Docket No. 50-607, for the University of California - Davis McClellan Nuclear Research Center Training, Research, Isotope, General Atomics nuclear reactor. By letter dated July 6, 2020 (ML20188A368), the licensee updated its LRA to reflect its decision to reduce the licensed thermal operating power level from 2.3 megawatt thermal (MWt) to 1.0 MWt, and to eliminate pulsing capability and irradiation of explosive materials in the reactor tank.
The U.S. Nuclear Regulatory Commission (NRC) staff identified additional information needed to continue its review of the LRA, as described in the enclosed request for additional information (RAI). As discussed with Dr. Wesley Frey of your staff, by telephone on May 16, 2022, provide a response to the RAI or a written request for additional time to respond, including the proposed response date and a brief explanation of the reason, 30 days from the date of this letter.
Following receipt of the complete response to the RAI, the NRC staff will continue its review of the LRA.
The response to the RAI must be submitted in accordance with Title 10 of the Code of Federal Regulations (10 CFR) 50.4, Written communications, and pursuant to 10 CFR 50.30(b), Oath or affirmation, be executed in a signed original document under oath or affirmation. Information included in the response that you consider sensitive or proprietary, and seek to have withheld from public disclosure, must be marked in accordance with 10 CFR 2.390, Public inspections, exemptions, requests for withholding. Any information related to safeguards should be submitted in accordance with 10 CFR 73.21, Protection of Safeguards Information:
Performance Requirements.June 3, 2022 If you have any questions regarding the NRC staffs review or if you intend to request additional time to respond, please contact me at (301) 415-0893, or by electronic mail at Geoffrey.Wertz@nrc.gov.
Sincerely, Geoffrey Wertz, Project Manager Non-Power Production and Utilization Facility Licensing Branch Division of Advanced Reactors and Non-Power Production and Utilization Facilities Office of Nuclear Reactor Regulation Docket No. 50-607 License No. R-130
Enclosure:
As stated cc: See next page Signed by Wertz, Geoffrey on 06/03/22
University of California-Davis/McClellan Docket No. 50-607
cc:
David Reap, Radiation Safety Officer 5335 Price Avenue, Bldg. 258 McClellan, CA 95652-2504
California Energy Commission 1516 Ninth Street, MS-34 Sacramento, CA 95814
Radiologic Health Branch California Department of Public Health P.O. Box 997414, MS 7610 Sacramento, CA 95899-7414
Test, Research and Training Reactor Newsletter Attention: Ms. Amber Johnson Dept of Materials Science and Engineering University of Maryland 4418 Stadium Drive College Park, MD 20742-2115
Dr. Wesley D. Frey, Reactor Director McClellan Nuclear Research Center University of California, Davis 5335 Price Avenue, Building 258 McClellan, CA 95652-2504
ML22146A194 NRR-088 OFFICE NRR/DANU/UNPL/PM NRR/DANU/UNPL/LA NRR/DANU/UNPL/BC NRR/DANU/UNPL/PM NAME GWertz NParker JBorromeo GWertz DATE 6/2/2022 6/2/2022 6/3/2022 6/3/2022 OFFICE OF NUCLEAR REACTOR REGULATION
REQUEST FOR ADDITIONAL INFORMATION
REGARDING RENEWAL OF FACILITY OPERATING LICENSE NO. R-130
UNIVERSITY OF CALIFORNIA-DAVIS/MCCLELLAN NUCLEAR RESEARCH CENTER
DOCKET NO. 50-607
The U.S. Nuclear Regulatory Commission (NRC) staff reviewed the license renewal application for compliance with Title 10 of the Code of Federal Regulations (10 CFR) using the following guidance and standard(s):
The regulation, 10 CFR 20.1301, Dose limits for individual members of the public, which states (a) Each licensee shall conduct operations so that - (1) The total effective dose equivalent to individual members of the public from licensed operations does not exceed 0.1 rem (1 mSv) in a year, and, (d) A licensee or license applicant may apply for prior NRC authorization to operate up to an annual dose limit for an individual member of the public of 0.5 rem (5 mSv). The licensee or license applicant shall include the following information in this application: (1)
Demonstration of the need for and the expected duration of operations in excess of the limit in paragraph (a) of this section; (2) The licensee's program to assess and control dose within the 0.5 rem (5 mSv) annual limit; and (3) The procedures to be followed to maintain the dose as low as is reasonably achievable.
NUREG-1537 Part 1, Guidelines for Preparing and Reviewing Applications for the Licensing of Non-Power Reactors, Format and Content, issued February 1996 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML042430055)
NUREG-1537 Part 2, Guidelines for Preparing and Reviewing Applications for the Licensing of Non-Power Reactors, Standard Review Plan and Acceptance Criteria, issued February 1996 (ML042430048)
Interim Staff Guidance for the Streamlined Research Reactor License Renewal Process, A. Adams to K. Brock, October 15, 2009 (ML092240256 and ML092240244)
The NRC staff review of the University of California Davis (UCD), McClellan Nuclear Research Center (MNRC) loss-of-coolant accident (LOCA) used the guidance in NUREG-1537, Part 2, Chapter 13, Accident Analyses, Loss of Coolant, which states that licensees should analyze potential LOCAs, and states, in part, that a LOCA could cause the uncovered reactor core to constitute an unshielded gamma ray source.
The NRC staff review finds that the radiation dose rates, as stated in Section 13.2.3.2.2.3, Radiation Levels from the Uncovered Core for the LOCA scenario, Table 13-11, Scattered Radiation Dose Rates at the MNRC Fence Line After a Loss of Pool Water Accident Following
Enclosure
1 MW Operations, of the UCD/MNRC SAR (redacted version ML20238B984) appear to represent the highest radiation dose that a member of the public could receive following a LOCA. The NRC staff also finds the dose rates provided in Table 13-11 would result in a radiation dose to a member of the public, located outside the controlled area boundary of the UCD/MNRC fence, in excess of the annual radiation limit specified in 10 CFR 20.1301(a)(1) of 100 millirem (mrem), within a few hours of exposure following the LOCA.
Further, the NRC staff review of the licensees SAR did not identify any systems or equipment credited to potentially mitigate or reduce the dose rates following a LOCA. Also, the NRC staff review of the licensees Emergency Plan, Revision 9, dated June 2018 (redacted version ML20238B990), did not find any protective actions to remove or evacuate members of the public from the areas outside the controlled area boundary of the UCD/MNRC fence, in order to mitigation the potential radiation dose.
In order to continue with its review, the NRC staff requires the following additional information:
- 1. As necessary to demonstrate compliance with 10 CFR Part 20 dose limits and consistent with the guidance in NUREG-1537, provide a comprehensive updated description of the UCD/MNRC LOCA scenario, including a timeline of the major activities or assumptions, the postulated cause of the leak, the drain-down rate, the assumed time for the core to become uncovered, and any changes to the calculated dose rates, if identified.
- 2. As necessary to demonstrate compliance with 10 CFR Part 20 dose limits and consistent with the guidance in NUREG-1537, provide the proposed plans to reduce or mitigate the potential radiation exposure to a member of the public such that the postulated LOCA scenario would not result in any member of the public receiving an annual dose in excess of 100 mrem, as required by 10 CFR 20.1301, such as:
2.1. operator actions and/or facility equipment planned to be used to mitigate the consequences of the LOCA, and whether the equipment should be included in the technical specifications.
2.2. procedures or processes to mitigate the consequences of the LOCA, including any changes to the UCD/MNRC Emergency Plan.
2.3. support needed from any off-site local support agencies, officials, or emergency response organizations, including the use of any signed agreements.
2.4. any other planned actions credited to mitigate the consequences of the LOCA.
- 3. The regulation, 10 CFR 20.1301(d) states that [a] licensee or license applicant may apply for prior NRC authorization to operate up to an annual dose limit for an individual member of the public of 0.5 rem (5 mSv). The licensee or license applicant shall include the following information in this application:
(1) Demonstration of the need for and the expected duration of operations in excess of the limit in paragraph (a) of this section;
(2) The licensee's program to assess and control dose within the 0.5 rem (5 mSv) annual limit; and
(3) The procedures to be followed to maintain the dose as low as is reasonably achievable.
If an increase of the annual dose limit for an individual member of the public is being requested, provide the information stated in 10 CFR 20.1301(d)(1)-(3), listed above.