MONTHYEARIR 05000607/20232022023-12-15015 December 2023 University of California-Davis - U.S. Nuclear Regulatory Commission Security Inspection Report No. 05000607/2023202 (Public) IR 05000607/20232012023-02-23023 February 2023 University of California - Davis U.S. Nuclear Regulatory Commission Routine Inspection Report 05000607/2023201 IR 05000607/20222022022-12-28028 December 2022 University of California-Davis - Us Nuclear Regulatory Commission Routine Inspection Report No. 05000607/2022202 IR 05000607/20222012022-05-26026 May 2022 University of California-Davis U.S. Nuclear Regulatory Commission Routine Inspection Report No 05000607/2022201 ML21300A3922021-12-23023 December 2021 University of California-Davis U.S. Nuclear Regulatory Commission Routine Inspection Report No. 05000607/2021202 IR 05000607/20212022021-12-0606 December 2021 University of California-Davis - Nuclear Regulatory Commission Security Inspection Report No. 05000607/2021202 Cover Letter IR 05000607/20212012021-05-0707 May 2021 University of California-Davis - U. S. Nuclear Regulatory Commission Routine Inspection Report No. 05000607/2021201 IR 05000607/20202022020-08-0303 August 2020 University of California-Davis - U.S. Nuclear Regulatory Commission Routine Inspection Report 05000607/2020202 IR 05000607/20192032019-08-30030 August 2019 University of California, Davis/Mcclellan Nuclear Research Center - U.S. Nuclear Regulatory Commission Routine Inspection Report No. 50-607/2019-203 IR 05000607/20192022019-07-0303 July 2019 University of California-Davis - U.S. Nuclear Regulatory Commission Security Inspection Report No. 50-607/2019-202 IR 05000607/20192012019-02-15015 February 2019 University of California-Davis - U.S. Nuclear Regulatory Commission Routine Inspection Report 05000607/2019201 IR 05000607/20182022018-09-20020 September 2018 University of California, Davis/Mcclellan Nuclear Research Center - U.S. Nuclear Regulatory Commission Routine Inspection Report No. 50-607/2018202 IR 05000607/20172022017-06-19019 June 2017 University of California-Davis - Nuclear Regulatory Commission Security-Related Inspection Report 05000607/2017202 ML17044A2582017-03-0303 March 2017 University of California-Davis - Nuclear Regulatory Commission Routine Inspection Report No. 50-607/2017-201 ML16256A0822016-09-30030 September 2016 University of California, Davis/Mcclellan Nuclear Research Center -U.S. Nuclear Regulatory Commission Routine Inspection Report No. 50-607/2016-202 ML16048A6142016-03-10010 March 2016 IR 05000607/2016201, February 8�11, 2016, University of California-Davis - Nuclear Regulatory Commission Routine Inspection Report IR 05000607/20152032015-11-18018 November 2015 IR 05000607/2015203, on October 19-22, 2015 at the University of California-Davis - NRC Routine Inspection IR 05000607/20152012015-03-12012 March 2015 IR 05000607/2015201, February 9-12, 2015, University of California-Davis - NRC Routine Inspection IR 05000607/20132022013-06-12012 June 2013 IR 05000607-13-202 - NRC Security Inspection Report - University of California, Davis IR 05000607/20132012013-02-12012 February 2013 IR 05000607/2013-201 on January 14-16, 2012 at University of California, Davis - NRC Routine Inspection Report No. 50-607/2013-201 IR 05000607/20122032012-08-0606 August 2012 IR 05000607-12-203 on July 9-11, 2012 at the University of California-Davis - NRC Routine Inspection Report No. 50-607/2012-203 and Notice of Violation ML12208A0342012-08-0606 August 2012 IR 05000607-12-203 on July 9-11, 2012 at the University of California-Davis - NRC Routine Inspection Report No. 50-607/2012-203 and Notice of Violation IR 05000607/20122022012-05-17017 May 2012 IR 05000607-12-202, on 04/3012 - 05/02/12, University of California, Davis - NRC Security Related Inspection Report IR 05000607/20092012009-03-12012 March 2009 IR 0500607-09-201; Mcclellan Nuclear Radiation Center; 02/17-19/2009; NRC Routine Inspection Report IR 05000607/20072022007-10-29029 October 2007 IR 50-607-07-202 on 10/15/2007 - 10/18/2007 for University of California-Davis IR 05000607/20072012007-05-0404 May 2007 IR 50-607-07-201, on April 16-19, 2007, for UC-Davis Mcclellan Nuclear Radiation Center IR 05000607/20062022006-12-21021 December 2006 NRC Routine, Announced Inspection Report No. 50-607/2006-202 IR 05000607/20062032006-12-18018 December 2006 Cover Letter for NRC Inspection Report No. 50-607/2006-203 IR 05000607/20062012006-08-23023 August 2006 IR 05000607-06-201, 07/31-08/03/2006, University of California - Davis, Mcclellan Nuclear Radiation Center, Review of Selected Aspects of the Licensee'S 2 Megawatt Class I Research and Test Reactor Safety Programs Including: Organizational IR 05000607/20052012006-04-20020 April 2006 IR 05000607-05-201, on 12/05-09/2005, University of California, Davis IR 05000607/20012012002-02-27027 February 2002 IR 05000607/2001-201, Mcclellan Nuclear Radiation Center Research Reactor on 10/01-05/2001 Related to Organization & Staffing, Review & Audit Functions, Plant Operations, Procedures, Maintenance & Surveillance & Radiation Protection Program IR 05000607/19992011999-06-0303 June 1999 Insp Rept 50-607/99-201 on 990330-0401.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000607/19982011998-07-30030 July 1998 Insp Rept 50-607/98-201 on 980615-19.No Violations Noted. Major Areas Inspected:Review of Selected Conditions & Records,Observation of Physical Plant,Ongoing Operations, Surveys,Surveillances & Related Discussions W/Personnel 2023-02-23
[Table view] Category:Letter
MONTHYEARML24032A1352024-02-0101 February 2024 Examination Confirmation Letter No. 50-607/OL-24-01, University of California-Davis ML23332A7062023-11-27027 November 2023 University of California, Davis Mcclellan Nuclear Research Center (MNRC) License Holder Appointment ML23263A9762023-09-22022 September 2023 Regents of the Ucd Issuance of Amendment No. 10 to Renewed Facility Operating License R-130 ML23262B5202023-09-19019 September 2023 University of California Davis Mcclellan Nuclear Research Center (Mnrc), Docket Number 50-607, License Number R-130, Supplement to License Amendment Request 2023-02 ML23258A2422023-09-15015 September 2023 University of California Davis Mcclellan Nuclear Research Center (Mnrc), Docket Number 50-607, License Number R-130, License Amendment Request 2023-02 ML23222A1872023-08-10010 August 2023 Univ. of California, Davis, 14-Day Written Follow-up to Call Made to the HOO (EM 56643) on July 28th 2023 ML23095A0652023-03-14014 March 2023 American Nuclear Insurers, Notice of Cancellation Rescinded ML23045A0452023-03-0202 March 2023 Regents of the University of California - Issuance of Amendment No. 9 to Renewed Facility Operating License No. R-130 to Amend the Technical Specifications for the University of California - Davis/Mcclellan Nuclear Research Center ML23073A3992023-03-0101 March 2023 University of California Davis Mcclellan Nuclear Research Center (MNRC) License Holder Appointment IR 05000607/20232012023-02-23023 February 2023 University of California - Davis U.S. Nuclear Regulatory Commission Routine Inspection Report 05000607/2023201 ML23045A3202023-02-14014 February 2023 14 Day Notification to Document Control Desk of Event 56331 Made to NRC Operations Center by UC Davis MNRC on February 1st at 1651 Est ML23039A2072023-02-0808 February 2023 University of California Davis Mcclellan Nuclear Research Center (Mnrc), Docket Number 50-607, License Number R-130, License Amendment Request 2023-01 IR 05000607/20222022022-12-28028 December 2022 University of California-Davis - Us Nuclear Regulatory Commission Routine Inspection Report No. 05000607/2022202 ML22214B8292022-11-21021 November 2022 Letter to Ucd with Renewed Facility Operating License ML22213A1692022-10-18018 October 2022 Regents of the University of California - Environmental Assessment and Finding of No Significant Impact Regarding Renewal of Facility Operating License No. R-130 for the University of California - Davis/Mcclellan Nuclear Research Center ML22213A1622022-10-18018 October 2022 FRN Re UCD-MNRC Environment Assessment ML22193A2532022-07-12012 July 2022 Univ. of California-Davis - Summary of the Analysis of Changes Made to the MNRC Emergency Plan Under the Provisions of 10 CFR 50.54q ML22181B0822022-06-30030 June 2022 University of California-Davis/McClellan Nuclear Research Center, Response to NRC Request for Additional Information Letter Dated June 24th, 2022 Regarding License Renewal Application ML22174A2932022-06-28028 June 2022 Regents of the University of California - Report on the Regulatory Audit License Renewal Application for the University of California - Davis/Mcclellan ML22173A2092022-06-24024 June 2022 Regents of the University of California; Request for Additional Information Regarding License Renewal Application for the University of California ML22174A4222022-06-23023 June 2022 Additional Response to NRC Request for Additional Information Letter Dated June 3rd 2022 Regarding License Renewal Application for the University of California-Davis/McClellan Nuclear Research Center ML22173A2022022-06-22022 June 2022 Response to NRC Request for Additional Information Letter Dated June 3rd 2022 Regarding License Renew Al Application for the University of California - Davis/Mcclellan Nuclear Research Center ML22172A1982022-06-21021 June 2022 UC Davis MNRC Submission of Technical Specification in Support of License Renewal Application ML22154A5442022-06-0303 June 2022 Univ. of CA - Davis, MNRC Submittal of Technical Specification in Support of License Renewal Application ML22154A5482022-06-0303 June 2022 University of California - Davis, Submittal of MNRC 2021 Annual Report ML22146A1942022-06-0303 June 2022 Regents of the University of California - RAI Regarding License Renewal Application for the University of California - Davis/Mccellan Nuclear Research Center IR 05000607/20222012022-05-26026 May 2022 University of California-Davis U.S. Nuclear Regulatory Commission Routine Inspection Report No 05000607/2022201 ML22137A2602022-05-26026 May 2022 University of California - Davis - Closure of Confirmatory Action Letter No. NRR 02 002 on the Site-Specific Compensatory Measures Implementation Plan ML23142A3032022-05-22022 May 2022 Univ. of California - Davis, Submittal of MNRC 2022 Annual Report ML22109A1042022-05-0303 May 2022 Regents of the Univ. of CA - Review of the Physical Security Plan in Support of License Renewal Application for the Univ. of CA-Davis/McCellan Nuclear Research Center ML22089A1582022-03-30030 March 2022 UC Davis MNRC Response to NRC Staff Request for Additional Information Regarding Licensing Renewal Application Letter Issued February 8th, 2022 ML22041A3782022-02-28028 February 2022 Regents of the University of California - Determination of Acceptability and Sufficiency for Docketing and Opportunity for Hearing Regarding the License Renewal Application for the University of California - Davis/Mcclellan Nuclear Research ML22038A1402022-02-0808 February 2022 Regents of the University of California - Request for Additional Information Regarding License Renewal Application for the University of California - Davis/Mcclellan Nuclear Research Center ML22026A2862022-02-0202 February 2022 Regents of the University of California - Regulatory Audit Re License Renewal Application for the University of California - Davis/Mcclellan Nuclear Research Center Training, Research, Isotope, General Atomics Nuclear Reactor ML22014A1272022-01-11011 January 2022 50 .54P Submittal of the Ucd/Mnrc Physical Security Plan for University of California, Davis Mcclellan Nuclear Research Center (Ucd/Mnrc), Docket No. 50-607, Facility Operating License No. R-130 the ML21300A3922021-12-23023 December 2021 University of California-Davis U.S. Nuclear Regulatory Commission Routine Inspection Report No. 05000607/2021202 ML21351A3172021-12-17017 December 2021 UC Davis MNRC Response to NRC Staff Request for Additional Information Regarding Licensing Renewal Application Letter Issued November 30th, 2021 IR 05000607/20212022021-12-0606 December 2021 University of California-Davis - Nuclear Regulatory Commission Security Inspection Report No. 05000607/2021202 Cover Letter ML21316A1162021-11-30030 November 2021 Regents of the University of California - Request for Additional Information Regarding License Renewal Application for the University of California-Davis Mccellan Nuclear Research Center ML21252A7572021-10-0505 October 2021 University of California-Davis/MCCLELLAN - Approval of the Revised Nuclear Radiation Center Selection and Training Plan ML21265A5412021-09-22022 September 2021 UC Davis MNRC Cover Letter for Response to Request for Supplemental Information ML21250A3662021-09-14014 September 2021 Regents of the University of California Report on the Regulatory Audit License Renewal Application for the University of California Davis/Mcclellan Nuclear Research Center Triga Nuclear Reactor ML21175A3342021-06-22022 June 2021 Transmittal of University of California, Davis, MNRC 2020 Annual Report IR 05000607/20212012021-05-0707 May 2021 University of California-Davis - U. S. Nuclear Regulatory Commission Routine Inspection Report No. 05000607/2021201 ML21029A1472021-01-25025 January 2021 UC Davis Mcclellan Nuclear Research Center - 50.54P Submittal of the Ucd/Mnrc Physical Security Plan ML20338A2622020-12-10010 December 2020 NRR-106 University of California Davis License Renewal - Regulatory Audit Letter and Plan ML20295A4242020-11-16016 November 2020 Notification of Mailing Address Change Regarding Submittal of Fingerprint Cards ML20261H3882020-09-17017 September 2020 Updated UC Davis MNRC Reactor Proposed License Renewal Ipac Trust Resources Report ML20245E5672020-09-0303 September 2020 University of California, Davis - Review of the Emergency Plan in Support of the Renewal for Facility Operating License No. R 130 IR 05000607/20202022020-08-0303 August 2020 University of California-Davis - U.S. Nuclear Regulatory Commission Routine Inspection Report 05000607/2020202 2024-02-01
[Table view] |
Text
ust 23, 2006
SUBJECT:
NRC INSPECTION REPORT NO. 50-607/2006-201
Dear Dr. Flocchini:
On July 31 - August 3, 2006, the U.S. Nuclear Regulatory Commission (NRC) conducted an inspection at your University of California-Davis McClellan Nuclear Radiation Center. The enclosed report documents the inspection results, which were discussed on August 3, 2006, with W. Steingass, Reactor Supervisor, and other members of your staff.
The inspection examined activities conducted under your license as they relate to safety and compliance with the NRCs rules and regulations and with the conditions of your license. The inspector reviewed selected procedures and records, observed activities, and interviewed personnel. Based on the results of this inspection, no findings of significance were identified.
In accordance with Section 2.390, Public inspections, exemptions, and requests for withholding, of Title 10 of the Code of Federal Regulations (CFR), a copy of this letter, its enclosure, and your response (if any) will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records component of NRCs Agencywide Documents Access and Management System (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).
Should you have any questions concerning this inspection, please contact Craig Bassett at 404-358-6515.
Sincerely,
/RA/
Johnny H. Eads, Branch Chief Research and Test Reactors Branch B Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket No. 50-607 License No. R-130 Enclosure: NRC Inspection Report No. 50-607/2006-201 cc w/enclosure: See next page
University of California - Davis/McClellan MNRC Docket No. 50-607 cc:
Mr. Jeff Ching 5335 Price Avenue, Bldg. 258 McClellan AFB, CA 95652-2504 Test, Research, and Training Reactor Newsletter University of Florida 202 Nuclear Sciences Center Gainesville, FL 32611
August 23, 2006 Dr. Robert