ML062220473
| ML062220473 | |
| Person / Time | |
|---|---|
| Site: | Indian Point (DPR-026) |
| Issue date: | 06/12/2006 |
| From: | Mcmullin K Entergy Nuclear Operations |
| To: | Boska J, Cobey E, Brian Holian, Diane Jackson, David Lew, Noggle J, Neil Sheehan NRC/NRR/ADRO |
| References | |
| FOIA/PA-2006-0244 | |
| Download: ML062220473 (5) | |
Text
Ezyi-fýP -ý L From:"a en M" <KMcMull@entergy.com>
To:
ow*
Baranski, James" <james.baranski@semo.state.ny.us>,"
Eddy, Paul" <pau~eddy@dps.statei.y.us>, 'Greeley, Dan, <greeleyd@co.rockland.ny.us>, "Gross, Steve - Orange PIO" <sgross@co.orange.ny.us>, "Sutton, Tony" <awsl @westchestergov.com>,
<AStiebeling @pcbes.org>, "Albanese, Raymond" <rlal @westchestergov.com>, "Alfredo Vidal'
<avidal@thevidalgroup.com>, <awsl @weschestergov.com>, "B. Gore" <bgore@ urbanomics.com>,
<bakerna@co.rockland.ny.us>, "Barry, Terrence" <TBarry@entergy.com>, 'Benjamin, Liz"
<BenjamiL@co.rockland.ny.us>, 'Bentley, Robyn M" <rbentle@entergy.com>,
<ken.bergmann@semo.state.ny.us>, 'Bernie McGarry" <mcgarry@ senate.state.ny.us>, "Blizard, Andrea J" <ablizar@entergy.com>, <jean-bordewich@schumer.senate.gov>, <schumer@valstar.net>,
<jpbl @nrc.gov>, "Bowman, Greg" <GBowm90@cc :s13.pod ent
>, <beh @ nrc.gov>,
<JBridges@troopers.state.ny.us>, 'Chief Tubb_..
C hris Schwarz" W L
<cschwar@entergy.com>, <ewc@nrc.gov>, "Comiotes, Jim' <JComlot@entergy.com>, "Conroy, Patric W' <PConroy@entergy.com>, <lindac@yorktownny.org>, 'Cox, Mark R" <mcox90@entergy.com>,
<Gcrawford @ urbanomics.com>, "Curra C
cu use.gov>, "Dacimo, Fred R."
<FDacimo@entergy.com>, "David Bran
$David Greene"
)(e,,nP-+ 6
<dgreene@ urbanomics.com>, "David W inraub" <DWeinraub @ bmwlobby.com>, "DeGasperis, Edward M" <edegasp @entergy.com>, "DiRocco, Anthony J' <ADirocc@ entergy.com>,
<Donald.Maurer@ semo.state.ny.ust*, *D i@ dele sm- @westchestergov.com>,
<Barney.Drew@ lafarge-na.com>,
'Fay, Deborah' <DFayl @entergy.com>,
'Feathers" <Jdf@fcwc-law.com>, <An-drewFeen*<
@s m.statp
>peter.feroemail.house.gov>,
<galefs@assembly.state.ny.us>, "Ger Shapiro 4 r-6
<Emily.Gibbons@mail.house.gov>, "Giguere, KOaleen M" <lKitgur@ en'tergy.com>, "Gottlieb, Laurence'
<LGottll@entergy.com>, 'Greene, Dominick" <dgreene@co.orange.ny.us>,
<gac7@westchestergov.com>, 'Grosjean, Alain G" <AGrosje@entergy.com>, <grtroes@nppd.com>,
<Frank.Guiao@ lafarge-na.com>, 'Harry Giannoulis' <harry@theparksidegroup.com>, 'Hinrichs, Gary H'
<ghinric@entergy.com>, "Hipschman, Thomas ' <thips90@ entergy.com>, "lnzirillo, Frank"
<finziri@entergy.com>, "Ira Promisel' <ipromise@troopers.state.ny.us>, "Jack Spath"
<Jps@ nyserda.org>, <dej1 @ nrc.gov>, <Jefft @townofcortlandt.com>, "Jensen, Chris'
<Jensenc@co.rockland.ny.us>, 'JES' <JES1 @westchestergov.com>, "Jim Cunningham"
<jim.cunningham @ nyc.bm.com>, "Jim Wright" <wright@ senate.state.ny.us>, 'John Cordo" <JLC@fcwc-law.com>, "Jones, T. R.0 <tjones2 @entergy.com>, "Kansler, Michael R" <MKansle@ entergy.com>,
'Kathleen Wood" <kathleen.wood @ chamber.state.ny.us>, <Pat.keegan @malI.house.gov>, "Kems, Matthew To <MKems@entergy.cor>, <MKopy@troopers.state.ny.us>, <kevin.kraus@semo.state.ny.us>,
"L. Leach "Leach, Don MI <DLeach @entergy.com>,
<leibell@senate.state.ny.us>, 'Leon, Pete" <Pete.Leon@maUl.house.gov>, <DCL@nrc.gov>, "Longo, Nick" <longon@co.rockland.ny.us>, "Mark Serrano' <serrano@proactivecom.com>, 'Martin Brennan"
<MartinBrennan @schumer.senate.gov>, "Marvin Randolph" <mrandolph @ urbanomics.com>, "Mayer, Donald M" <DMayerl @entergy.com>, 'McCann, John (ENNE Licensing Director)"
<jmccanl @entergy.com>, "McCannell, Chris' <Chds.mccannell@mall.house.gov>, "McConaghy, Ryan'
<ryanMcConaghy@schumer.senate.gov>, "McGillicuddy, Maura' -,MMcCd>j.j*e.teQor>
- Kay, Mike" <mlke.mckay@ mall.house.gov>, "McMahon, Bob - Putman Couny.
i
=
"McMullin, Kathleen M" <KMcMull@entergy.com>, <millera@assembly.sta e.ny.us>,
<MillerC @ co.rockland.ny.us>, "Mitchell, Frank J" <FMitche @ entergy.com>, 'Neil Sheehan'
<nas@nrc.gov>, <rand @schildasset.com>, <jdn@nrc.gov>, <Joseph.o'brien@mall.house.gov>,
<boliveira@ amnuclns.com>, <doneill @ bghc-law.com>, "Pat Brown" <PBrown @ bmwlobby.com>, 'Paul Steidler" <paul@effectivecomm.org>, 'Paul Tonko" <tonkop@ assembly.state.ny.us>, "Paulson, Adam"
<adam.paulson @mail.house.gov>, <alp 0 nyserda.org>, 'Phillips, Frank M.' <fphllli @entergy.com>,
<pjk3 @ westchestergov.com>
Date:
06/12/2006 5:42:27 PM
Subject:
IPEC status report for June 12, 2006 See attached Information in this record was dele~ed in accordance with the Freedom of Informti0n Act, exemptions FOIA-6 --%_-_4Y
Kathleen McMullin Manager, Communications Indian Point Energy Center 914-271-7132 work 914-827-7779 fax cell
See attached Kathleen McMullin Manager, Communications Indian Point Energy Center 914-271-7132 work 914-827-7779 fax cell
Indian Point Energy Center Status Report June 12,2006 Operational Status IP2 is currently at 100% reactor power, the unit has been on line for 25 days and Unit 3 is operating at 100% reactor power and has been on-line for 251 days.
Groundwater Investigation MW-42 Well - Updated sample results Monitoring Well - 42, located near the Unit 1 spent fuel pool and north curtain drain system is a multi-level well from which samples have been obtained at various depths by the NRC, DEC and Entergy. Entergy's results are shown in the table below. The results show isotopes characteristic of North curtain drain water. No radioactivity has been detected in any off-site monitoring location.
Date Depth H-3 Sr-90 Cs-137 Co-60 NI-63 March 49 ft 2630 51.9 102,000 194 NA 22/23 78 ft 1280 ND 4460 208 NA April 7 49 ft 3980 73.7 53,100 67.2 5120 78 ft 792 ND 1980 ND 36.6 Note: Some data corrected from previous reports
- Monitoring Well Results Date ID Location H-3 Sr-90 4/2612006 U3-D4 Unit 3 turbine building 575 ND 411112006 MW-51 Southeast edge of ND pending monitoring area 3131/2006 MW-52 Northeast edge of ND pending monitoring area Note: MDA for tritium is 500 pCi/L
- IP2 Spent Fuel Pool Liner Inspection Entergy has begun the second phase of the spent fuel pool liner inspection.
Previously, the accessible areas of the pool above the fuel racks were inspected and six suspect areas coated with epoxy. Last week, Entergy began the inspection of the walls adjacent to the fuel racks. There is a narrow gap between the wall and the racks which makes camera movement difficult.
,---...----.-~.
-~
rdy~ ~
- Unit I Containment Spray Sump Entergy has pumped down the Unit I containment spray pump which is located in the old superheater structure. The sump tested positive for Sr-90 and the 14,000 gallons of water will be processed through a dimineralizer before being discharged through the plant's routine discharge path. A visual and video inspection of the sump will be conducted.
IP2 Spent Fuel Pool Leak Collection Box The volume of water collected from the 1P2 SFP leak collection system continued to drop from the May readings as shown on the table below. No short lived isotopes have been found in the leak collection system. Tritium concentrations have also dropped Date Volume (ml) 4/5/06 105 4/14/06 674 4/21/06 403 4/26/06 7
5/3/06 46 5/10/06 1008 5/15106 1263 5/24/06 1386 5/31/06 901 6/7/06 431 Educational Outreach Entergy Nuclear Northeast provides customized outreach education programs for schools, youth groups, and civic organizations. The topics we cover include Emergency Planning, Understanding Radiation, Nuclear Fuel and a general overview of the operations of Indian Point Energy Center. If you would like a brochure or are interested in scheduling a program, contact IPEC Communications at 914-271-7441.
If you have any questions or need clarification of the information provided, please contact Kathy McMullin, manager of communications, Indian Point Energy Center, at 914-271-7132.