ENCLOSURE 1 TENNESSEE VALEY AUTHORITY BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 RADIOLOGICAL IMPACT ASSESSMENT 2004 El-l

Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2004

1. INTRODUCTION Potential doses to the "maximum exposed individual" and the population around Browns Ferry are calculated for each quarter as required in Section 5.2 of the Offsite Dose Calculation Manual (ODCM). The methodology for determining plant releases for the reporting period used to estimate dose is specified in Sections 6 and 7 of the ODCM. Dispersion of radioactive effluents in the environment is estimated using meteorological data and river flow measured during the period. In this report, the doses resulting from releases are described and compared to limits established for Browns Ferry.

[E. DOSE LIM1TS The ODCM specifies limits for the release of radioactive effluents, as well as limits for doses to the general public from the release of radioactive effluents. These limits are set well below the Technical Specification limits which govern the concentrations of radioactivity and doses permissible in unrestricted areas. This ensures that radioactive effluent releases are As Low As Reasonably Achievable.

The air dose limits in areas at and beyond the Site Boundary due to noble gases released in gaseous effluents per unit are:

< 5 nirad per quarter and

< 10 mnrad per year for gamma radiation.

-and-

< 10 mrad per quarter and

< 20 mrad per year for beta radiation.

The dose limits to a Member of the Public in an unrestricted area from radioiodines, radioactive materials in particulate form, and radionuclides other than noble gases with half-lives > 8 days released in gaseous effluents for each unit are:

< 7.5 mrem per quarter and

< 15 mrem per year to any organ.

The dose or dose commitment to a Member of the Public from radioactive material in liquid effluents released to unrestricted areas are:

< 1.5 mrem per quarter and

<3 mrem per year to the total body,

-and -

< 5 mrem per quarter and

< 10 mirem per year to any organ.

The limit for the total effective dose equivalent to an individual Member of the Public inside the site boundary is:

100 mrem per year.

The EPA limits for, total dose to any Member of the Public in the vicinity of a nuclear power plant, established in the Environmental Dose Standard of 40 CFR 190, are:

  • 25 mrem per year to the whole body,

< 75 mrem per year to the thyroid,

-and-

  • 25 mrem per year to any other organ.

E1-2

Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2004 M. DOSEACLTIN Estimated doses to Members of the Public are determined using computer models (the Gaseous Effluent Licensing Code. GELC, and the Quarterly Water Dose Assessment Code, QWATA). These models are based on guidance provided by the NRC (in Regulatory Guides 1.109, 1.111 and 1.113) for determining the potential dose to individuals and populations living in the vicinity of the plant The area around the plant is analyzed to determine the pathways through which the public may receive a dose. The doses calculated are a representation of the dose to a "maximum exposed individual." Some of the factors used in these calculations (such as ingestion rates) are maximum values to ensure conservative reporting data. Many of these factors are obtained from NUREGICR-1004. The values chosen will tend to overestimate the dose.

The expected dose to actual individuals is lower. The calculated doses are presented in Tables 1, 2. 3, 4. 5, 6, 7, 8, and 9.

IV. DOSES FROM AIRBORNE EFFLUENTS For airborne effluents, Members of the Public can be exposed to radiation from several sources: direct radiation from the radioactivity in the air, direct radiation from radioactivity deposited on the ground, inhalation of airborne radioactivity, ingestion of vegetation which contains radioactivity deposited from the atmosphere, and ingestion of milk and beef which contains radioactivity deposited from the atmosphere onto vegetation and subsequently consumed by milk and beef animals.

Airborne Release Points There are four monitored release points from Browns Ferry Nuclear Plant the turbine building, the radwaste building, the reactor building, and the stack.

Releases from the turbine building are considered ground-level releases. The ground-level Joint Frequency Distribution (JFD) is derived from windspeeds and directions measured 10 meters above ground and from the vertical temperature difference between 10 and 45 meters, and are presented for each quarter in Tables 10, 11, 12, and 13.

Releases from the radwaste and reactor buildings are considered split-level releases. Portions of the release are treated as ground-level while other portions are considered elevated depending on the ratio of the vertical exit velocity to the horizontal wind speed. The split-level dispersion approach is implemented using a model that requires two complete quarterly JFDs for each effluent vent, one for the ground-level releases and one for the elevated releases. The ground-level portion of the split-level JWD is based on wind speeds and directions measured 10 meters above ground-level and from the vertical temperature difference between 10 and 45 meters. The elevated portion of the split-level JFD is based on wind speeds and direction measurements at the 45 meter level and the vertical temperature difference between 45 and 91 meters. Both of these JFDs are given for each quarter in Tables 14, 15, 16, 17, 18, 19, 20, and 21.

Releases from the stack are considered to be elevated releases. The JFDs for elevated releases are based on wind directions and wind speeds measured at 91 meters and the vertical temperature difference between 45 and 91 meters, and are given for each quarter in Tables 22, 23, 24, and 25.

El-3

Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2004 Meteorolonical Data Meteorological variables at BFN are measured continuously. Measurements collected include wind speed, wind direction, and temperature at heights of 10, 45, and 91 meters above the ground. Quarterly JFDs are calculated for each release point using the appropriate levels of meteorological data. A quarterly JFD gives the percentage of the time that the wind is blowing out of a particular upwind compass sector in a particular range of wind speeds for a given stability class A through G. The wind speeds are divided into nine wind speed ranges. Calms are distributed by direction in proportion to the distribution of noncalm wind directions less than 1.6 m/s (3.5 mph). Stability classes are detennined from the vertical temperature difference between two measurement levels.

The generally open terrain around BFN does not cause any significant effects on the transport and dispersion of gaseous effluents from the plant. Within 30 kilometers of BEFN, the terrain is mostly gently rolling hills (30-60 meters). Between 30 and 80 kilometers the hills become larger to the north and south, and mountainous to the east and northeast. The Tennessee River/Wheeler Lakle may have a minor effect on transport and dispersion in the immediate vicinity of BFN during periods of winds with a southerly component, overcast skies, and relatively high wind speeds. Also, the lower layer (1045 meters) stability class tends to be more stable. However, during this infrequent condition, dose estimates will be conservative.

External Exposure Dose Dose calculated for maximum external air dose (gamma-air and beta-air ) are made for points at and beyond the unrestricted area boundary as described in the BFN ODCM. The highest of these doses is then selected.

Submersion Dose External doses to the skin and total body, due to submersion in a cloud of noble gases, are calculated for the nearest residence in each sector. The residence with the highest dose is then selected from all sectors.

Organ Dose Dose to an organ due to releases of airborne effluents are estimated for the inhalation, ground contamination, and ingestion pathways. The ingestion pathway is further divided into three possible contributing pathways: ingestion of cow/goat milk, ingestion of beef, and ingestion of vegetables. Doses from applicable pathways are calculated for each receptor location identified in the most recent land use survey. To determine the maximum organ dose, the doses from the pathways are summed for each receptor.

For the ingestion dose, however, only those pathways that exist for each receptor are considered in the sum, e.g., milk ingestion doses are included only for locations where milk was consumed without commercial preparation and vegetable ingestion is included only for those locations where a garden was identified. To conservatively account for beef ingestion, a beef ingestion dose equal to that for the highest unrestricted area boundary location is added to each identified receptor. For ground contamination, the dose added to the organ dose being calculated is the total body dose calculated for that location, i.e., it is assumed that the dose to an individual organ is equal to the total body dose.

The maximum organ dose, thyroid dose, and total body dose from airborne effluents are presented in Tables 1, 2, 3, and 4.

El-4

Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2004 V. DS ES For liquid effluents, the public can be exposed to radiation from three sources: the ingestion of water from the Tennessee River, the ingestion of fish caught in the Tennessee River, and direct exposure from radioactive material deposited on the river shoreline sediment (recreation).

The concentration of radionuclides in the Tennessee River are calculated by a computer model which uses measured hydraulic data downstream of BFN. Parameters used to determine the doses are based on guidance given by the NRC (in Regulatory Guides 1.109) for maximum ingestion rates, exposure times, etc.

Wherever possible, parameters used in the dose calculation are site specific. The models that are used to estimate doses, as well as the parameters input to the models, are described in detail in the BFN ODCM.

kiguid Release Points and River Data Radionuclide concentrations in the Tennessee River are calculated assuming that releases in liquid effluents are continuous. When necessary, liquid releases from BFN, located at Tennessee River Mile 294, are made through diffusers which extend into the Tennessee River. It is assumed that releases to the river through these diffusers will initially be entrained in one-fifth of the water which flows past the plant. The QWATA code makes the assumption that this mixing condition holds true until the water is completely mixed at the first downstream dam (Wheeler Dam), at Tennessee River Mile 283.0.

Doses are calculated for locations within a 50 mile radius downstream of the plant site. The maximum potential recreation dose is calculated for a location inmediately downstream from the plant's release point.

The maximum exposed individual dose from ingestion of fish is assumed to be that calculated for the consumption of fish caught anywhere between the plant and the first downstream dam. The maximum exposed individual dose from drinking water is assumed to be that calculated at the nearest downstream public water supply (West Morgan - East Lawrence (WELL)]. This could be interpreted as indicating that the maximum exposed individual, as assumed for liquid releases from Browns Ferry, is an individual who obtains all of his drinking water at WMEL, consumes fish caught from the Tennessee River between BFN and Wheeler Dam, and spends 500 hours0.00579 days <br />0.139 hours <br />8.267196e-4 weeks <br />1.9025e-4 months <br /> per year on the shoreline just downstream of the plant's release point. Doses calculated for the maximum exposed individual due to liquid effluents for each quarter in the period are presented in Tables 5, 6, 7, and 8, along with the average river flows past the plant site for the periods.

VI. POPULATION DOSES Population doses due to airborne effluents are calculated for an estimated 778,266 persons living within a 50-mile radius of the plant site. Doses from external pathways and inhalation are based on the 50-mile human population distribution. Ingestion population doses are calculated assuming that each individual consumed milk, vegetables, and meat produced within the sector in which the individual resides.

Population doses due to liquid effluents are calculated for the entire downstream Tennessee River population. Water ingestion population doses are calculated using actual population figures for downstream public water supplies. Fish ingestion population doses are calculated assuming that all sport fish caught in the Tennessee River are consumed by the Tennessee River population. Recreation population doses are calculated using historical recreational data on the number of shoreline visits at downstream locations.

Population doses calculated for airborne and liquid effluents are presented in Tables 1, 2, 3, 4, 5, 6, 7, and 8.

El-S

Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2004 VII. OFFSITE DIRECT RADIATION DOSE External gamma radiation levels were measured by thermoluminescent dosimeters (TLDs) deployed around BFN as part of the offsite Radiological Environmental Monitoring Program (REMP). The quarterly gamma radiation levels determined from these TLDs during this reporting period averaged approximately 17 mrem/quarter at onsite (at or near the site boundary) stations and approximately 14.75 mrem/quarter at offsite stations or approximately 2.3 mrem/quarter higher onsite than at offsite stations. This difference is consistent with levels measured for pre-operation and construction phases of TVA nuclear plants where the average radiation levels onsite were generally 2-6 mrem/quaxter higher than the levels offsite. This may be attributable to natural variations in environmental radiation levels, earth moving activities onsite, the mass of concrete employed in the construction of the plants, or other undetermined influences. Fluctuations in natural background dose rates and in TLD readings tend to mask any small increments which may be due to plant operations. Thus, there was no identifiable increase in dose rate levels attributable to direct radiation from plant equipment and/or gaseous effluents.

VM. DOSE TO A NIEMEBER OF THE PUBLIC INSIDE THE SITE BOUNDARY Pursuant to ODCM section 7.7.5, a review was performed to determine the highest dose to a member of the public in the site boundary. This review assumed that onsite TVA employees engaged in work activities not associated with nuclear power electric generation were considered as members of the public. The dose to a member of the public consists of the sum of dose commitments from effluent releases as well as any direct radiation dose. The effluent dose commitment is negligible compared to the direct radiation dose.

The direct radiation dose was determined from area TLDs located onsite. It consisted of gamma dose from the plume, ground contamination and from equipment sources (i.e., tanks, turbine shine, radioactive material storage areas, etc.). The highest direct radiation dose accounting for background and occupancy was 4.8 mrem during 2004.

The total annual dose commitment to the member of the public for 2004 is 4.8 mrem; the direct radiation dose while in the site boundary. It can be concluded that the dose limit for a member of the public inside the site boundary as specified in 10 CFR 20.1301 was not exceeded.

El-6

Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2004 IX TOTAL DOSE To determine compliance with 40 CFR 190, annual total dose contributions to the maximum exposed individual from BFN radioactive effluents and all other nearby uranium fuel cycle sources are considered.

The annual dose to any organ other than thyroid for the maximum exposed individual is conservatively calculated by summing the following doses: the total body air submersion dose for each quarter, the critical organ dose (for any organ other than the thyroid) from airborne effluents for each quarter from ground contamination, inhalation and ingestion, the total body dose from liquid effluents for each quarter, the maximum organ dose (for any organ other than the thyroid) from liquid effluents for each quarter, and any identifiable increase in direct radiation dose levels as measured by the REMP. This dose is compared to the 40 CFR 190 limit for total body or any organ dose (other than thyroid) to determine compliance.

The annual thyroid dose to the maximum exposed individual is conservatively estimated by summing the following doses: the total body air submersion dose for each quarter, the thyroid dose from airborne effluents for each quarter, the total body dose from liquid effluents for each quarter, the thyroid dose from liquid effluents for each quarter, and any identifiable increase in direct radiation dose levels as measured by the REMP. This dose is compared to the 40 CFR 190 limit for thyroid dose to determine compliance.

Total dose from the fuel cycle is presented in Table 9.

El-7

Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2004 Table 2 Doses from Airborne Effluents Second Quarter Individual Doses Pathway Dose Quarterly Limit Percent of Limit Location External Gamma Air I.OE-1 1 mrad 5 mrad

< I %

N/1525 meters Beta Air 3.2E-11 mrad 10 mrad

<I %

N/1525 meters Submersion Total Body 1.IE-03 mrem NA NA N/2000 meters Skin 1.3E-03 mrem NA NA Nn2000 meters Organ Doses Child/Liver 1.2E-02 mrem 7.5 mrem

< I %

NNW/1791 meters Child/Thyroid 4.5E-03 mrem 7.5 mrem

< 1 %

NNW/1791 meters Adult /Total Body 5.OE-03 mrem 7.5 mrem

<1 %

NNW/1791 metrs P02ulation Doses Total Body Dose 1.3E-02 man-rem Maximum Organ Dose (organ) 1.7E-02 man-rem (liver)

Population doses can be compared to the natural background dose for the entire 50-mile population of about 70,044 man-rem/year (based on 90 mrem/yrfor natural-background).

E1-9

Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2004 Table 3 Doses from Airborne Effluents Third Quarter Individual Doses Pathway Dose Quarterly Limit Percent of Limit Location External Gamma Air 2.2E-06 mrad 5 mrad

<1 %

E/6600 meters Beta Air 6.6E-06 mrad 10 mrad

<1 %

E/6600 meters Submersion Total Body 7.9E-04 mran NA NA E/1290 meters Skin 9.2E-04 mrem NA NA E/1290 meters Organ Doses Child/Liver 6.0E-03 rnrem 7.5 mrem

< I %

NNW/1791 meters Child/Tlhwroid 2.9E-03 nirem 7.5 mrem

< 1%

NNW/1791 meters Adult/Total Body 2.5E-03 mrem 7.5 mrem

<I %

NNW/1791 meters Population Doses Total Body Dose 1.4E-02 man-rem Maximum Organ Dose (organ) 1.9E-02 man-rem (liver)

Population doses can be compared to the natural background dose for the entire 50-mile population of about 70,044 man-rem/year (based on 90 mrem/yrfor natural background).

El-10

Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2004 Table 4 Doses from Airborne Effluents Fourth Quarter Individual Doses Pathway Dose Quarterly Limit Percent of Limit Location External Gamma Air 4.6E-11 mrad 5 mrad

<1 %

NNW/1650 meters Beta Air 1.4E-10 mrad 10 mrad

<1 %

NNW/1650 meters Submersion Total Body 1.6E-03 mrem NA NA NNW/1639 meters Sldn 1.8E-03 mrem NA NA NNW/1639 meters Organ Doses Chlild/ Liver 1.5E-02 mrem 7.5 mrem

< 1 %

NNW/1791 meters ChildtThyroid 7.6E-03 mrem 7.5 mrem

<1 %

NNW/1791 meters Adult /Total Body 5.9E-03 mrem 7.5 mrem

<1 %

NNW/1791 meters PoDulation Doses Total Body Dose 1.2E-02 man-rem Maximum Organ Dose (organ) 1.8E-02 man-rem (liver)

Population doses can be compared to the natural background dose for the entire 50-mile population of about 70,044 man-rem/year (based on 90 mrem/yrfor natural background).

El-1l

Radiologic- 'impact Assessment Browns Ferry Nuclear Plant January - December 2004 Table 5 Doses from Liquid Effluents First Quarter*

Individual Doses (mrem)

Age Group Organ Dose Pathway Dose Quarterly Percent of Limit Limit Total Body Fish Ingestion 0

Recreation 0

Water Ingestion 0O Total 0

1.5 mrem 0 %

Fish Ingestion 0

Recreation 0

Water Ingestion 0

Total 0

5 mirem O

Thyroid Fish Ingestion 0

Recreation 0

Water Ingestion 0

Total 5

mrem 0%

  • No liquid releases were made this quarter.

Average Riverfiow past BFN (cubic feet per second): No Release Population Doses Total Body Dose 0 man-rem Maximum Organ Dose (organ) 0 man-rem (organ)

Population doses can be compared to the natural background dose for the entire 50-mile population of about 70,044 man-rem/year (based on 90 mren/myrfor natural background).

E1-12

Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2004 Table 6 Doses from Liquid Effluents Second Quarter*

Individual Doses (turem)

Age Group Organ Dose Pathway Dose Quarterly Percent of Limit Limit Total Body Fish Inestion 0

Recreation 0

Water Ingestion 0

Total 0

1.5 mrem 0 %

Fish Ingestion 0

Recreation 0

_ Water Ingestion 0

Total 0

Smrem 0 %

Thyroid Fish Ingestion 0

Recreation 0

Water Ingestion 0

Total 0

5 nuem 0 %

  • No liquid releases were made this quarter.

Average Riverflow past BFN (cubic feet per second): No Release PopuIation Doses Total Body Dose 0 man-rem Maximum Organ Dose (organ) 0 man-rem (organ)

Population doses can be compared to the natural background dosefor the entire 50-mile population of about 70,044 man-remnyear (based on 90 mrem/yr for natural background).

El-13

Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2004 Table 7 Doses from Liquid Effluents Third Quarter*

Individual Doses (rnrem)

Age Group Organ Dose Pathway Dose Quarterly Percent of Limit Limit Total Bfish Ingestion 0

Recreation 0

Water Ingestion 0

Total 0

1.5 uirem 0 %

Fish Ingestion 0

______._E___Recreation 0

Water Ingestion 0

Total 0

S mrem 0 %

Thyroid Fish Ingestion 0

Recreation 0

Water Ingestion 0 ° Total 0

5 mrem 0 %

  • No liquid releases were made this quarter.

Average Riverflow past BFN (cubic feet per second): No Release Population Doses Total Body Dose 0 man-rem Maximum Organ Dose (organ) 0 man-rem (organ)

Population doses can be compared to the natural background dosefor the entire 50-mile population of about 70,044 man-rem/year (based on 90 mremnyrfor natural background).

E1-14

Radiological Imp-^t Assessment Browns Ferry Nuclear Plant January - December 2004 Table 8 Doses from Liquid Effluents Fourth Quarter*

Individual Doses (nrem)

Age Group Organ Dose Pathway Dose Quarterly Percent of Limit Limit Total Body Fish Ingestion 0

Recreation 0

Water Ingestion 0

Total 0

1.Smrem 0%

Fish Ingestion 0

Recreation 0

Water Ingestion 0

Total 0

5 mrem 0%o Thyroid ish Ingestion 0

Recreation 0

Water Ingestion 0

Total 0

5 mrem 0 %

  • No liquid releases were made this quarter.

Average Riverfiow past BFN (cubic feet per second): No Release Population Doses Total Body Dose 0 man-rem Maximum Organ Dose (organ) 0 man-rem (organ)

Population doses can be compared to the natural background dosefor the entire 50-mile population of about 70,044 man-rem/year (based on 90 mremlyrfor natural background).

El-15

Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2004 Table 9 Total Dose from Fuel Cycle First Second Third Fourth Dose Quarter Quarter Quarter Quarter Total Body or any Organ (except thyroid)

Total body air submersion 1.8E-03 1.1E-03 7.9E-04 1.6E-03 Critical organ dose (air) 2.OE-02 1.2E-02 6.OE-03 l.5E-02 Total body dose (liquid) 0 0

0 0

Maximum organ dose (liquid) 0 0

0 0

Direct Radiation Dose 0

0 0

0 Total 2.2E-02 1.3E-02 6.8E-03 1.7E-02 Cumulative Total Dose (mrem)

(Total body or any other organ) 5.9E-02 Annual Dose Limit (mrem) 2.5E+01 Percent of Limit

<1%

Thyroid Dose (mrem)

Total body air submersion 1.8E-03

1. IE-03 7.9E-04 1.6E-03 Thyroid dose (airborne) 1.6E-02 4.5E-03 2.9E-03 7.6E-03 Total body dose (liquid) 0 0

0 0

Thyroid dose (liquid) 0 0

0 0

Direct Radiation Dose 0

0 0

0 Total 1.8E-02 5.6E-03 3.7E-03 9.2E-03 Cumulative Total Dose (Thyroid) mrem 3.7E-02 Annual Dose Limit (mrem) 7.5E+01 Percent of Limit

<1%

E1-16

ENCLO JRE 2 TENNESSEE VALLEY AUTHORITY BROWNS FERRY NUCLEAR PLANT (BFN)

UNITS 1, 2, AND 3 METEOROLIGICAL DATA TABLES 2004 E2-1

METEOROLOGICAL DATA TAB3LES BROWNS FERRY NUCLEAR PLANT JANUARY - DECEMBER 2004 TABLE 10 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR GROUND LEVEL RELEASES FIRST QUARTER E2-2

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A IDELTA T<=-1.9 C/100 M)

Browns Ferry Nuclear Plant JAN 1,

2004 - MAR 31, 2004 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

sSw SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED (MPH)

CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0,6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.093 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.140
0. 000
0. 000
0. 000
0. 000 0.000 0.000 0.465.

0.698 0.698 0.651 0.326 0.000 0.093 0.000 0.000 0.000 2.932 0.093 0.000 0.000 0.000 0.000 0.000 0.279 0.047 0.465 0. 000 0. 000 0.1B6 0.093 0.140 0.000 0.000 1.303 0.140 0.186 0.000

0. 000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.047 0.558 0.233 0.047 1.256 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.047 0.465 0.140 0.326 1.070 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 TOTAL 0.000 0.326 0.000 0.186 0.000 0.000 0.000 0o 000 0.000 0.000 0.000 0.000 0.000 0.791 0.000 0.745 0.000 1.256 0.000 0.651 0.000 0.372 0.000 0.186 0.000 0.279 0.000 1.163 0.000 0.372 0.000 0.372 0.000 6.701 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS A TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS TOTAL HOURS CALM METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LBVEL 2159 144 144 2149 0

DATE PRINTED: 2004/05/13 MEAN WIND SPEED =

7,49 NOTE; TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2 -3

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

Browns Ferry Nuclear Plant JAN 1, 2004 -

MAR 31, 2004 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL O. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.140 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.233 0.000 0.000 0.000 0.047 0.047 0.093 0.279 0.186 0.093 0.093 0.047 0.093 0.093 0.093 0.047 0.000 1.210 0.093 0.186 0.047 0.000 0.000 0.000 0.047 0.047 0.140
0. 000 0.000 0,047 0.233 0.326 0.186 0.047 1.396 0.233 0.140 0.047 0.000 0.000 0.047 0.000 0.000 0.000 0.000 O.000 0.000 0.047 0.372 0.372 0.279 1.536 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.233 0.000 0.047 0.279 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0,000
0. 000
0. 000 0.000 0.000 0.047
0. 000
0. 000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.326 0.326 0.093 0.093 0.047 0.140 0.326 0.233 0.372 0.093 0.047 0.186 0.372 1.070 0.605 0.372 4.700 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS B TOTAL TOTAL TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS HOURS CALM 2159 101 101 2149 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BBTWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED = 7.36 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2004/05/13 E2-4

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.S C/100 M)

Browns Ferry Nuclear Plant JAN 1, 2004 -

MAR 31, 2004 WIND WIND SPEED(MPH)

DIRECTION CALM 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

0.000 0.000 0.000 0.000 0.093 0.279 0.047 0.000 0.000 0.419 NNE 0.000 0.000 0.000 0.047 0.279 0.000 0.000 0.000 0.000 0.326 NE 0.000 0.000 0.000 0.047 0.000 0.093 0.047 0.000 0.000 0.186 ENE 0.000 0.000 0.000 0.000 0.047 0.047 0.000 0.000 0.000 0.093 E

0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.047 ESE 0.000 0.000 0.000 0.140 0.000 0.000 0.000 0.000 0.000 0.140 SE 0.000 0.000 0.047 0.233 0.047 0.000 0.000 0.000 0.000 0.326 SSE 0.000 0.000 0.047 0.233 0.047 0.000 0.000 0.000 0.000 0.326 5

0.000 0.000 0.233 0.093 0.047 0.000 0.000 0.000 0.000 0.372 SSW 0.000 0.000 0.140 0.000 0.000 0.000 0.000 0.000 0.000 0.140 SW 0.000 0.000 0.093 0.000 0.047 0.000 0.000 0.000 0.000 0.140 WSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 W

0.000 0.000 0.000 0.140 0.093 0.140 0.000 0.000 0.000 0.372 WNW 0.000 0.000 0.047 0.140 0.140 0.186 0.093 0.000 0.000 0.605 NW 0.000 0.000 0.000 0.047 0.093 0.186 0.047 0.000 0.000 0.372 NNW 0.000 0.000 0.000 0.047 0.093 0.186 0.047 0.000 0.000 0.372 SUBTOTAL 0.000 0.000 0.605 1.163 1.070 1.117 0.279 0.000 0.000 4.235 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2159 TOTAL HOURS OF STABILITY CLASS C 91 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C 91 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2149 TOTAL HOURS CALM 0

METEOROLOGICAL FACILITY:

Browns Perry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2004/05/13 MEAN WIND SPEED -

6.52 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-5

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

Browns Ferry Nuclear Plant JAN 1, 2004 -

MAR 31, 2004 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE ESE SE SSE S

ssW SW WSW W

WNW NW NhW 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000
0. 000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.093 0.140 0.140 0.326 0.326 0.512 0.931 0.931 0.605 0.186 0.047 0.326 0.326 0.047 0.093 0.140 0.5S8 0.512 0,372 0.465 0.372 0.279 0.838 0.931 0.512 0.093 0.047 0.233 0.512 0.233 0.233 0.419 0.745 1.349 0.605 0.512 0.047 0.884 0.279 0.093 0.279 0.000 0.047 0.093 0.326 0.279 0.419 0.512 1.070 1.163 0.884 0.279 0.093 0.326 0.093 0.000
0. 000 0.000
0. 000 0.186 0.512 1.768 2.792 1.908 0 093 0.047 0.372 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.140 1.443 0.838 0.233 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.00 0 0.000 0.000
0. 047 0.000 2.559 3.211 2.373 1.582 0.83S 2.001 2.141 1.954 1.396 0.279 0.140 0.838 1.815 3.816 4.467 3.211 SUBTOTAL 0.000 0.000 5.165 6.608 6.468 11.075 3.164 0.093 0.047 32.620 TOTAL HOURS OF VALID STABILITY TOTAL HOURS OF STABILITY CLASS OBSERVATIONS D

TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS TOTAL HOURS CALM METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL 2159 703 701 2149 0

DATE PRINTED: 2004/05/13 MEAN WIND SPEED =

7.39 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-6

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

Browns Ferry Nuclear Plant JAN 1,

2004 -

MAR 31, 2004 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL 0.000

0. 000 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0. 000 0.000 0.000 0.000
0. 000
0. 000 0.140 0.047 O.000 0.047 0.047 0.000 0.000 0.047 0.140 0.047 0.047 0.093 0.047 0.186 0.093 0.093 0.558 0.651 0.512 0.372 0.558 1.163 0.745 1.163 1.210 0.558 0.651 0.698 0.372 0.279 0.512 0.558 1.163 0.558 0.698 0.372 0.465 0.698 0.838 0.558 0.931 0.047 0.047 0.233 0.745 0.140 0.279 0.745 0.233 0.186 0.419 0.093 0.093 0.326 0.419 0.000 0.512 0.465 0.093 0.047 0.140 0.140 0.465 0.651 0.465 0.372 0.27 9 0.047 0.000 0.186 0.372 0.140 0.605 0.372 0.000 0.000 0.047 0.326 0.931 0.465 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.047 0.140 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 2.606 1.815 1.908 0.931 1.163 2.373 2.373 1.908 3.443 1.489 0.838 1.070 1.349 1.117 2.420 2.606 SUBTOTAL 0.000 1.070 10.563
8. 516 4.281 4.607 0.372 0.000 0.000 29.409 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS e TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E 2159 638 632 2149 0

TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY TOTAL HOURS CALM OBSERVATIONS METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10,50 METER LEVEL DATE PRINTED: 2004/05/13 MEAN WIND SPEED = 4.76 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-7

JOINT PERCENTAGE PREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5c DELtA T<= 4.0 C/100 M)

Browns Perry Nuclear Plant JAN 1, 2004 -

MAR 31. 2004 WIND DIRECTION CALM WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WsW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 O.000 0.000 0.000 0.047 0.093 0.000 0.093 0.140 0.140 0.233 0.093 0.140 0.140 0.093 0.186 0.000 0.093 0.000 0.047 1.536 0.465 0.186 0.372 0.419 0.372 0.605 1.536 1.303 0.372 0.093 0.093 0.047 0.093 0.372 0.186 0.419 6.933 0.558 0.465 0.093 0.186 0.372 0.186 0.279 0.372 0.977 0,093 0.000 0.000 0.047 0.000 0.186.

0.419 4.235 0.047 0.140 0.047 0.000 0.000 0.000 0.047 0.047 0.977 0.047 0.000 0.000 0.000 0.000 0.047 0.000 1.396 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.093 0.931 0.093 0.000 0.000 0.000 0.000 0.000 0.047 1.163 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.117 0.884 0.512 0.698 0.884 0.931
2. 094
1. 908 3.443
0. 465
0. 186 0.233 0.140 0.465 0.419
0. 931 0.000 15.309 TOTAL HOURS TOTAL HOURS TOTAL HOURS TOTAL HOURS TOTAL HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS F OF VALID WIND DIRECTION-WrND SPEED-STABILITY CLASS F OF VALID WIND DIRECTION-WrND SPEED-STABILITY OBSERVATIONS CALM 2159 330 329 2149 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2004/05/13 MEAN WIND SPBED =

3.63 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2 -8

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

Browns Perry Nuclear Plant JAN 1, 2004 -

MAR 31, 2004 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW SUBTOTAL CALM 0.002 0.001 0.002 0.001 0.002 0.002 0.005 0.020 0.005 0.001 0.000 0.000 0.000 0.002 0.002 0.003 0.047 WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5,5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>-24.5 TOTAL 0.000 0.047 0.047 0.000 0.047 0.000 0.186 0.372 0.047 0.000 0.000 0.000 0.000 0.000 0.093

0. 000 0.838 0.186 0.093 0.140 0.093 0.140 0.186 0.372 1.768 0.512 0.140 0.000 0.000 0.000 0.186 0.093 0.279 4.188 0.140 0.093 0O000 0.000 0.000 0.000 0.047 0.372 0.698 0.000 0.000 0.000 0.000 0.000 0.000 0.093 1.443 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.093 0.326 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.419 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.093
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000
0. 000
0. 000
0. 000 0.000
0. 000 0.327 0.234 0.188 0.094 0.188 0.188 0.610 2.626 1.680 0.141 0.000 0.000 0.000 0.188 0.188 0.375 7.027 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS G TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2159 152 151 2149 1

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED-2004/05/13 MEAN WIND SPEED =

2.87 NOTE TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-9

METEOROLOGICAL DATA TABLES BROWNS FERRY NUCLEAR PLANT JANUARY - DECEMBER 2004 TABLE 11 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR GROUND LEVEL RELEASES SECOND QUARTER E2-10 mmwffimmmmmm

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

Browns Ferry Nuclear Plant APR 1, 2004 - JUN 30, 2004 WIND DIRECTION WIND SPEEDIMPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NB ENE E

ESE SE SSE S

SSW SW WSW.

W WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000
0. 000 0.140 0.608 0.327 0.140 0.094
0. 000 0.000
0. 000
0. 000 0.000 1.309 0.000 0.000 0.000 0.000 0.000 0.094 0.514 0.795 0.982 0.608 0.327 0.094 0.047 0.000 0.000 0.000 3.460 0.000 0.047 0.000
0. 000 0.000 0.094
0. 000 0.000 0.047 0.047 0.000 0,047 0.374 0.047 0.140 0.047 0.888 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.047 0.608 0.888 0.514 2.057 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.'000 0.000 0.187 0.608 0.234 1.075 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000
0. 000
0. 000 0.000
0. 000 0.047 0.047 0.000 0.000 O.000 0.187 0.655 1.403 1.356 0,795 0.421 0.140 0.468 0.842 1.636 0.795 8.789 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS A TOTAL TOTAL TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS HOURS CALM 2142 189 188 2139 0

METEOROLOGICAL PACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2004/09/13 MEAN WIND SPEED =

6.92 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-11

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

Browns Ferry Nuclear Plant APR 1, 2004 - JUN 30, 2004 WIND DIRECTION WIND SPEED(MPH)

CALM 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE EME E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0,000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.234 0.281 0.421 0.1B7 0.140
0. 000 0.000
0. 000
0. 000 0.000 0.047 0.000 0.000 0.000 0.000 0.140 0.421 0.421 0.094 0.842 0.374 0.561 0.234
0. 000
0. 000
0. 000 0.047 0.000 0.000 0.000 0.047 0.047 0.000 0.000 0.047 0.187 0.000 0.187 0.140 0.094 0.000 0.000 0.094 0.000 0.094 0.000 0.000 O.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.140 0.281 0.281 O.000 0.000 0.000 O.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 O.000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000 0.000 0.000 0.187 0.000 0.094 0.000 0.047 0.187 0.655 0.701 0.561 1.216 0.514 0.748 0.374 0.234 0.327 0.327 SUBTOTAL 0.000 0.000 1.262 3.132 0.795 0.888 0.094 0.000
0. 000 6.171 TOTAL HOURS OF VALID STABILITY TOTAL HOURS OF STABILITY CLASS OBSERVATIONS B

TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B 2142 132 132 2139 0

TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY TOTAL HOURS CALM OBSERVATIONS METEOROLOGICAL FACILITY, Browns Ferry Nuclear Plant STABILITY BASED ON DBLTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2004/09/13 MEAN WIND SPEED =

5.10 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-12

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C f-1. 7< DELTA T<=-1. 5 C/100 4)

Browns Ferry Nuclear Plant APR 1, 2004 - JUN 30, 2004 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WsW W

WNW NW NNW SUBTOTAL WIND SPEED MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5,5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000
0. 000 0.000

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.468 0.561 0.514 0.421 0.094 0.047 0.000 0.000 0.000 0.000 2.104 0.000 0.000 0.047 0.000 0.047 0.047 0.140 0.094 0.140 0.234 0.047 0.655 0.140 0.140 0.000 0.000 1.730 0.094 0.000 0.000 0O.000 0.000 0.047 0.000 0.000 0.047 0.047 0.000 0.140 0.047 0.140 0.047 0.094 0.701 0.047 0.047 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.047 0.000 0.327 0.234 0.374 1.169 0.000 0;047 0.000 0.000 0.000 O.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0,000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.140 0.094 0.094 0.000 0.047 0.094 0.608 0.655 0,701 0.748 0.140 0.888 0.187 0.608 0.281 0.468 5.750 TOTAL HOURS OF VALID STABILITY TOTAL HOURS OF STABILITY CLASS OBSERVATIONS C

TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C 2142 123 123 2139 0

TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY TOTAL HOURS CALM OBSERVATIONS METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2004/09/13 MEAN WIND SPEED =

5.22 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-13

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

Browns Ferry Nuclear Plant APR 1, 2004 - JUN 30, 2004 WIND DIRECTION N

NNE NE ENS E

ESE SE SSS S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.6-1.4 WIND SPEED(MPH) 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5 -24.4

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 O.000 0.047 0.047 0.094 0.047 0,047 0.047 0.000 0.000 0.000 0.000 0.000 0.140 0.094 0.281 0.187 0.468 1.964 3.273 3.086 2.852 1.636 1.169 0.795 0.187 0.140 0.187 0.514 0.655 0.094 0.140 0.000 0.795 0.701 0.468 1.216 2.010 0.374 1.356 1.870 0.608 0.281 0.468 0,468 0.795 0.187 0.047 0.000 0.187 0.000 0.000 0.234 0.421 0.000 0.468 0.842 0.421 0.468 0.608 5.143 0.374 0.374 0.468 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0,000 0.047 0.561 1.029

0. 514 3.366 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.421 0.000 0.421 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0,000 0.000 0.000 1.356 1.964 0.842 0.468 0.187 1.449 2.712 3.787 4.628 5.330 2.057 3.039 3.S53 1.777 2.338 1.777 0.327 16.456 11.547 0.000 37.260 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS D TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS TOTAL HOURS CALM METEOROLOGICAL PACILITY:

Browns Ferry Nuclear Plapt STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METBRS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED =

4.35 2142 798 797 2139 0

DATE PRINTED: 2004/D9/13 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-14

JOINT PERCENTAGE FEEQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 H)

Browns Ferry Nuclear Plant APR 1, 2004 - JUN 30, 2004 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5 CALM

-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WsW W

WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.140 0.234 0.187 0.094 0.140 0.094 0.187 0.187 0.281 0.234 0.140 0.140 0.047 0.000 0.094 0.374 0.281 0.561 0,421 2.010 2.244 1.075 1.262 2.758 1.309 0.514 0.748

0. 421 0.187
0. 187 0.842 0.327 0.187 0.234 0.187 0.468 1.216 0.187 0.140 1.122 0.748
0. 000 0.094 0.421 0.094 0.281 0.795 0.094 0.094 0.187 0.000 0.047 0.000 0.000 0.000 0.374 0.094 0.000 0.000 0.000 0.047 0.327 0.281 0.094 0.047 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0,047
0. 514 0.094 0.000 0.000 0.000 0.000.

0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.234 0.000 0.000 0.000 0O.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0. 000 0O.000 0.000 0.000 0.000 0.000

0. 000
0. 000 0.935 0.748 1.262 0.795 2.618 3.600 1.356 1.590 4.441 2.431 0.748 0.982 1.029 0.421 1.543 2.104 SUBTOTAL 0.000 2.244 15.194 6.498 1.543 0.888 0.234 0.000 0.000 26.601 TOTAL HOURS OF VALID STABILITY TOTAL HOURS OP STABILITY CLASS OBSERVATIONS E

TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E 2142 570 569 2139 0

TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY TOTAL HOURS CALM OBSERVATIONS METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2004/09/13 MEAN WIND SPEED =

3.27 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-15

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F 1 1,5< DELTA T<= 4.0 C/100 M)

Browns Ferry Nuclear Plant APR 1,

2004 -

JUN 30, 2004 WIND DIRECTION CALM WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENS E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTDTAL

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 O.000 0.000 O.000 0.047 0.140 0.140 0.140 0.047 0.140 0.094 0.140 0.187 0.094 0.094 0.140 0.000 0.094 0.047 0.047 1.590 0.561 0.374 0.234 0.514 0.701 0.514 0.374 0.327 0.468 0.094 0.094 0.047 0.047 0.000 0.094 0.234 4.675 0,327 0.421 0.094 0;234 0.187 0.094 0.000 0.047 0.094 0O.000 0.000 0.000
0. 000 0.000 0.187
0.

514 2.197 0.047 0.094 0.187 0.000 0.000 0.000 0.000 0.000 0.000 D.000 0.000 0.000 0.000 0.000 0.234 0.140 0.701

0. 000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000 0.000 0.000
0. 000 0.140 0.140 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0,000 0.000 0.000
0. 000
0. 000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000 0.982 1.029 0.655 0.888 0.93>

0.748 0.468 0.514 0.748 0.187

0. 187 0.187 0.047 0.094 0.561 1.075 9.303 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS F TOTAL HOURS OP VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS TOTAL HOURS CALM 2142 199 199 2139 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2004/09/13 MEAN WIND SPEED =

3.02 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-16 m

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

Browns Ferry Nuclear Plant APR 1,

2004 - JUN 30, 2004 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.010 0.006 0.003 0.003 0.002 0.002 0.003 0.006 0.004 0.000 0.000 0.001 0.000 0.001 0.002 0.004 0.047 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL 0.608 0.374 0.140 0,047 0.047 0.140 0.234 0.187 0.094 0.047 0.047 0.094 0.000 0.000 0.234 0.140 2.431 0.514 0.281 0.234 0.281 0.187 0.140 0.094 0.514 0.374 0.000 0.000 0.000 0.000 0.094 0.000 0.281 2.992

  • 0.187 0.234 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0. 000 0.187 0.608 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.319
0. 941 0.377 0.330 0.236 0.283 0.330 0.707 0.472 0.047 0.047 0.094
0. 000 0.094 0.236 0.611 6.124 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS G TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS 0 OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2142 131 131 2139 1

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2004/09/13 MEAN WIND SPEED = 1.90 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-17

METEOROLOGICAL DATA TABLES BROWNS FERRY NUCLEAR PLANT JANUARY - DECEMBER 2004 TABLE 12 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR GROUND LEVEL RELEASES THIRD QUARTER E2-18

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-l.9 C/100 M)

Browns Ferry Nuclear Plant JUL 1,

2004 - SEP 30, 2004 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 1.5-24.4

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.366

0. 503 0.732
0. 091
0. 000
0. 000 0.000 0.000
0. 000
0. 000 1.693
0. 000 0.000 0.000 0.000 0.000 0.457 0.915 0.595 0.320 0.229 0.091 0.046 0.000 0.000 0.000 0.000 2.653 0.000 0.046 0.000 0.000 0.046 1.006 0.183 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 1.327 0.457 0.640
0. 091 0.000 0.000 0.229
0. 000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.046
0. 000 0.274 1.738 0.000 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.229 0.046 0.366 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.457 0.732 0.137 0.000 0.046 1.693 1.464 1.098 1.052 0.320 0.091 0.046 0.000 0.091 0.229 0.320 7.777 TOTAL HOURS OF VALID STABILITY TOTAL HOURS OF STABILITY CLASS OBSERVATIONS A

TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2187 170 170 2186 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED =

5.96 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2004/12/21 E2-19

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

Browns Ferry Nuclear Plant JUL 1, 2004 -

SEP 30, 2004 WIND DIRECTION WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 O.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 O. 000 0.000 0.000 0.091 0.046 0.046 0.046 0.137 0.046 0.046 0.000

0. 000 0.000 0.000 0.457 0.000 0.000 0.046 0.000 0.046 0.137 0.183 0.046 0.091 0.183 0.137 0.091 0.229 0.000 0.04 6 0.000 1.235 0.000 0.000 0.046 0.000 0.091 0.091 0.000 0.000 0.000 0.000 0.000 0.000 O.091 0.183 0.046 0.137 0.686 0.412 0.274 0.137 0.000 0.000
0. 000
0. 000
0. 000 0.000
0. 000 0.000 0.000
0. 091 0.046 0.274 0.274 1.510 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.046 0.091 0.000 0.229 0.000 0.000 0.000 0.000 I.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 O.000 0.000 0.000 0.000
0. 000 0.000
0. 000
0. 000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000 0.457 0.320 0.229 0.000 0.137 0.320 0.229 0.091 0.137 0.320 0.183 0.137 0.412 0.274 0.457 0.412 4.117 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPBED-STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2187 90 90 2186 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45,30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2004/12/21 MEAN WIND SPEED = 6.90 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2 -20

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<--1.5 C/100 N)

Browns Ferry Nuclear Plant JUL 1, 2004 -

SEP 30, 2004 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE R

ESE SE SSE S

SSw SW WSW W

WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL TOTAL 0.000 0.000

0. 000
0. 000 0.000 0.000
0. 000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.046 0.320 0.412 0.457 0.229 0.046
0. 091 0.046 0.046
0. 000
0. 000 1.784 0.046 0.137 0.046 0.046 0.091 0.274
0. 046 0.046 0.046 0.091 0.274 0.320 0.549 0.183 0.137 0.046 2.379 0.457 0.229 0.183 0.046 0.000 0.091 0.000 0.000 0.000 0.000 0.000 0.046 0.320 0.091 0.320 0.274 2.059 0.183 0.183 0.046 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.091
0. 091 0.274 0.274 1.144 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 O.000 0.000 0.000 0.000 0.046 0.091 0.046 0.183 O.000 O.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.686 0.549 0.274 0.137 0.137 0.412 0.366 0.457 0.503 0.320 0.320 0.457 1.006 0.457 0.823 0.640 7.548 HOURS OF VALID STABILITY OBSERVATIONS HOURS OF STABILITY CLASS C HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS HOURS CALM 2187 165 165 2186 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2004/12/21 MEAN WIND SPEED =

5.47 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-21

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

Browns Ferry Nuclear Plant JUL 1,

2004 -

SEP 30, 2004 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3,5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE E

ESE SE SSE S

SSw SW WSW W

WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000
0. 0oD 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.137 0.320 0.183 0.320 0.366 0.549 1.098 1.144 2.013 2.745
1. 098 1.006 0.732 0.229 0.274 0.137 1.464 0.869 0.229 0.183 0.503 0.686 0.229 0.137 0.229 0.274 0.091 0.915 1.784
0. 503 0.823 0.915 1.006 0.915 0.274 0.229 0.412 0.640 0.000 0.000 0.000 0.000 0.000 0.046 0.549 0.549 1.098 0.961 0.640 0.320 0.183 0.046
0. 000
0. 091
0. 000
0. 000
0. 000
0. 000 0,000
0. 046
0. 137 0.412 0.915 0.549 0.046 0.000 0.137 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.320 0.229 0.137 0.046 0.046 0.000 0.000 0.000 0.000
0. 000 D. 000 0.000 0.000 0.000 0.000 0.000 0.183 0.000 0.000 0.137 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 3.431 2.608 1.098 0.778 1.281 1.967 1.327 1.281 2.242 3.019 1.189
2. 013 3.202 1.693 3.660 2.790 SUBTOTAL 0.000 0.091 12.351 9.835 6.679 3.339 0.732 0.412 0.137 33,577 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS D TOTAL TOTAL TOTAL HOURS HOURS HOURS OP VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2187 734 734 2186 0

METEOROLOCICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2004/12/21 MEAN WIND SPEED =

5.08 NOTE; TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-22

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

Browns Ferry Nuclear Plant JUL, 1, 2004 -

SEP 30, 2004 WIND DIRECTION WIND SPEED (O 0.6-1.4 1.5-3.4 3.5-5.4 CALM 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENB E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0000 0.000 0.000 0.000 0.000 0.000 0.000 0.137 0.091 0.229 0.229 0,229 0.091 0.183 0.183 0.091 0.183 0.229 0.229 0.046 0.091 0.137 0.137 1.418 0.412 0.503 0.686 1.281 1.464 0.732 0.640
0. 686 0.778 0.778 0.778 0.778 0.229 0.457 1.235 1.098 0.732 0.274 0.320 1.327 1.189
0. 091 0.000
0. 000 0.046 0.000 0.000 0.503 0.091 0.229 0.915 0.366 0.686 0.366 0.046 0.137 1.006 0.000 0.000 0.000 0.000 0.000 0.000 0.137 0.000 0.274 0.457 0.046 0.274 0.137 0.000 0.000 0.091 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.137 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000
0. 000 0.000
0. 000 0.000
0. 000 0.000 0.000
0. 000
0. 000 0.000
0. 000 0.000 0.000 0.000 3.065 2.196 1.510 1.281 2.973 3.843 1.006 0.823 0.778 1. 006 1.006 1.006 1.464 0.412 1. 098 2.928 SUBTOTAL 0.000
2. 516 12. 855 6.816 3.477
0. 686 0.046 0.000 0.000 26.395 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS E TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E 2187 577 577 2186 0

TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY TOTAL HOURS CALM OBSERVATIONS METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2004/12/21 MEAN WIND SPEED =

3.45 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-23

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<- 4.0 C/100 M)

Browns Ferry Nuclear Plant JUL 1, 2004 -

SEP 30, 2004 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL 0.000 0.000

0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.183 0.229 0.274 0.046 0.046 0.046 0.091 0.046 0.046 0.000 0.046 0.000 0.046 0.046 0.137 0.137 2.013 0.686 0.457 1.006 1.052 0.366 0.000 0.046 0.091 0.229 0.046 0.046 0.000 0.137 0.091 0.823 2.287 0.915 0.183 0.640 1.052
0. 000
0. 000
0. 000 0.000 0.000
0. 000
0. 000 D. 000
0. 000
0. 091
0. 320 0.000 0.091 0.091 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.046 0.000
0. 000 0.000 0.000 0.000
0. 000
0. 000 0.000
0. 000
0. 000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 O.000 0.000 0.000 0.000 0.000 0.000 0.000 0O.000 0.000
0. 000 4.483 1.967 1.006 1.693 2.196 0.412 0.091 0.091 0.137 0.229 0.091 0.046 0.046 0.183 0.320 1.281 SUBTOTAL 0.000 1.418 7.091 5.489 0.229 0.04 6 0.000 0.000
0. 000 14.273 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS F TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS TOTAL HOURS CALM METEOROLOG[CAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45,30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED =

3.15 2187 313 312 2186 0

DATE PRINTED: 2004/12/21 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED PROM UNROUNDED NUMBERS E2-24

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

Browns Ferry Nuclear Plant JUL 1,

2004 - SEP 30, 2004 WIND DIRECTI ON N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-l8.4 18.5-24.4 CALM 0.000 0.000 0.000 I0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000' 0.000 0.000

>=24.5 TOTAL 0.503 0.229 0.229 0.000 o.000 0.000 0.046 0.046 0.000 0.000 0.000 0.046 0.000 0.000 0.412 0.640 2.150 1.006 0.503 0.274 0.320 0.046

0. 000
0. 000 0.000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000 0.137 0.229 2.516 1.052 0.04 6 0.046 0.274 0.183
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.046 1.647 0.000 0.000 0.000 0.000 0.000 O.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.000
0. 000 0.000
0. 000 0.000
2. 562 0.778 0.549 0.595 0.229 0.000 0.046 0.046 0.000 0.000

..000 0.046 0.000 0.000 0.549 0.915 6.313 TOTAL HOURS OP VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS G TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OF VALID WIND DIRECTION-WIND SPEED-STABILITY CALM CLASS G OBSERVATIONS 2187 138 138 2186 0

METEOROLOGICAL FACILITY:

Browns Perry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2004/12/21 MEAN WIND SPEED =

2.41 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-25

METEOROLOGICAL DATA TABLES BROWNS FERRY NUCLEAR PLANT JANUARY - DECEMBER 2004 TABLE 13 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR GROUND LEVEL RELEASES FOURTH QUARTER E2-26

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

Browns Ferry Nuclear Plant OCT 1,

2004 -

DEC 31, 2004 WIND DIRECTION CALM WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.141 0.047 0.000
0. 047
0. 000 0.000 0.000 0.000 0O.000 0.000 0.234
0. 000 0.047 0.000 0.000 0.000 0.047 0.422 0.562 0.562 0.094 0.000
0. 000
0. 000 0.000 0.000 0.000 1.734 0.047 0.047 0.000 0.000 0.000 0.234 0.187 0.141 0.187 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.843 0.141 0.047 0.000 0000 0.000 0.047 0.000 0.000 0.000
0. 000 0.000 0.000 0.187 0.000 0.094 0.141
0. 6S6 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.047 0.094 0.187 0.000 0.000 0.000 0.000 0.000 0, 000 0.000
0. 000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.047 0.047
0. 000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.187 0.141 0.000 0.000 0.000 0.328 0.750 0.750 0.7 50 0.141 0.000 0.000 0.187 0.047 0.141 0.281 3.702 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS A TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS TOTAL HOURS CALM 2151 79 79 2134 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2005/02/11 NEAN WIND SPEED = 6.53 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2 -27

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

Browns Ferry Nuclear Plant OCT 1,

2004 -

DEC 31, 2004 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 18.5-24.4 i=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

sSW SW wSW W

WNW NW OTW SUB3TOTAL 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 O.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.234 0.141
0. 000 0.047
0. 000 0.047
0. 000 0.000
0. 000 0.469 0.000 0.000 0.000 0.000 0.000 0.047 0,094 0.094 0.094 0.000 0.000 0.141 0.094 0.000 0.000 0.000 0.562 0.234 0.047 0.000 0.000 0.000 0.141 0.047 0.047 0.094 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.656 0.187 0.047
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000
0. 000 0.047 0.000 0.328 0.141 0.750 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.281 0.000 0.328 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000
0. 000 0.000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.422 0.141 0.000 0.000 0.000 0.187 0.141 0.375 0.328
0. 000 0.047 0.141 0.187 0.047
0. 609 0.141 2.765 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS B TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B 2151 59 59 2134 0

TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY TOTAL HOURS CALM OBSERVATIONS METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2005/02/1 MEAN WIND SPEED = 7.23 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-28

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/1OO M)

Browns Ferry Nuclear Plant OCT 1, 2004 -

DEC 31, 2004 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000
0. 000 0.047
0. 000 0.000 0.047 0.187 0,187 0.187 0.047 0.047 0.047 0.047 0.000 0.000 0.000 0.843 0.000 0.094 0.047 0.000 0.000 0.094 0.234 0.234 0.094 0.094
0. 0417 0.187 0.094 0.047 0.141 0.047 1.453 0.141 0.000 0.000 0.000 0.000 0.281 0.047 0.000 0.047 0.000 0.047 0.000 0.047 0.047 0.141
0. 047
0. 843 0.047 0.047 0.000 0.000
0. 000
0. 000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.094 0.187 0.375 0.094 0.843 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.094 0.094 0.187 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000
0. 000 0.000
0. 000
0. 000 0.187 0.141 0.094 0.000 0. OCO 0.422 0.469 0.422 0.328 0.141 0.141 0.234 0.281 0.281 0.750 0.281 4.171 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS C TOTAL HOURS TOTAL HOURS TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2151 89 89 2134 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2005/02/11 MEAN WIND SPEED = 5.80 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-29

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 H)

Browns Ferry Nuclear Plant OCT 1,

2004 -

DEC 31, 2004 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.187 0.141 0.000 0.094 0.094 0.000 0.000 0.000 0.000 0.000 0.562 0.187 0.094 0.234 0.562 0.515 0.797 1.125 1.031 1.593 0.703
0. 890 0.890 0.281 0.187 0.187 0.187 9.466 0.469 0.375 0.281 0.515 0.469 1.172 0.703 1.406 1.078 0.422 0.328 0.609 0.843 0.234 0.422 0.187 9.513 0.234 0.187 0.141 0.047 0.328 1.125 0.609 0.281 0.609 0.094 0.234 0.422 1.312 0.703 0.515 0.234 7.076 0.797 1.031 0.141 0.047 0.000 0.281 0.094 0.000 0.32B 0.047 0.000 0.094 1.359 0.750 1.828 0.562 7.357 0.000 0.047 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.094 1.125 1.172 0.187 2.624 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.141 0.047 0.000 0.187 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 1.687 1.734 0.797 1.172 1.312 3.421 2.718 2.858 3.608 1.359 1.546 2.015 3.889 3.140 4.171 1.359 SUBTOTAL 0.000 36.785 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS TOTAL HOURS OF STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D 2151 788 785 2134 0

TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS TOTAL HOURS CALM METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED =

6.09 DATE PRINTED: 2005/02/11 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-30

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

Browns Ferry Nuclear Plant OCT 1,

2004 -

DEC 31, 2004 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.S TOTAL N

NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0.000 0.000 0.000 0.000 0.000 O. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.047 0.187 0.000 0.094 0.047 0.187 0.328 0.234 0.375 0.234 0.141 0.047 0.047 0.047 0.094 0.000 0.562 0.375 0.609 1.218 1.031 1.500 1.312 1.640 1.828 0.609 0.422 0.469 0.422 0.187 0.094 0.422 0.562 0.562 0.703 0.422 1.218 1.687 0.656 1.406 1.734 0.141 0.187 0.187 0.750 0.187 0.141.

0.515 0.187 0.141 0.281 0.141 0.187 0.937 0.047 0.234 0.656 0.094 0.047 0.047 0,047 0.281 0.281 0.141 0.094 0.515 0.187

0. 000 0. 000
0. 000 0.000 0.000 0.422 0,047 0. 000
0. 000
0. 047 0.000 0.422
0. 234 0.000 0.D00 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000
0. 000 0.000 0.000
0. 000 1.453 1.781 1.781 1.874 2,484 4.311 2.343 3.515 5.014 1.125 0.797 0.750 1.312 0.703 1.031 1.312 SUBTOTAL 0.000 2.109 12.699 11.059 3.749 1.968 0.000 0.000 0.000 31.584 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL TOTAL TOTAL TOTAL HOURS OF STABILITY CLASS E HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B

HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS HOURS CALM 2151 6B1 674 2134 0

METEOROLOGICAL FACILITY:

Browns Perry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2005/02/11 MEAN WIND SPEED =

3.90 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-31

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F i 1.5< DELTA T<= 4.0 C/100 M)

Browns Ferry Nuclear Plant OCT 1,

2004 -

DEC 31, 2004 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENB ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.094 0.000 0.234 0.187 0.281 0.094 0.328 0.234 0.094 0.047 0.047 0.000 0.047 0.141 0.094 0.094 0.328 0.469 0.234 0.562 1.265 1.031 1.406 0.843 0.609 0.047 0.047 0.000 0.17 0.047 0.141 0.375 0.469 0.32 8 0.141 0.187 0.609 0.375 0.141 0.375 0.141 0.000 0.000 0.000 0.000 0.047 0.094 0 187 0.047 0.141 0.047 0.094 0.000 0.000 0.000 0.047 0.047 0.000 0.000 0.000 0.000 0.000 0.047 0.047 0.000 0.047

0. 000
0. 000
0. 000 0. 000
0. 000
0. 000
0. 047
0. 000
0. 000 0.000
0. 000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000 0.937 0.984 0,656 1.031 2.156 1.500 1.874 1.500 0.937 0.094 0.094
0. 000 0.234 0.234 0.375 0.703 SUBTOTAL 0.000 2.015 7.591 3.093 0.515 0.094 0.000 0.000 0.000 13.308 TOTAL TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2151 288 284 2134 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BBTWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2005/02/11 MEAN WIND SPEED =

2.85 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-32

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C (DELTA T > 4.0 C/100 H)

Browns Ferry Nuclear Plant OCT 1, 2004 -

DEC 31, 2004 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE SSW SW WSW W

WNW NW NNW SUBTOTAL 0.007 0.004 0.004 0.003 0.003 0.000 0.004 0.009 0.001 0.001 0.000 0.001

0. 001 0.002 0.002 0.005 0.047 0.375 0.187 0.141 0.047 0.094 0.047 0.234 0.141 0.000 0.094 0.047 0.047 0.047 0.141 0.047 0.234 1.921 0.656 0.422 0.375 0.422 0.281
0. 000 0.281 1.172 0.187 0.047 0.000 0.047 0.047 0.094 0.187 0.422 4.639 0.187 0.187 0.000 0.141 0.047 0.000 0.000 0.187 0.047 0.000 0.000 0.000
0. 000
0. 000 0.047 0.141 0.984 0.000 0.000 0.000 0.000 0.000 O.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.094 0.000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000
0. 000
0. 000
0. 000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 O.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.226 0.801 0.519 0.613 0.424 0.047 0.519 1.509 0.283 0.142 0.047 0.094 0.094 0.236 0.283 0.848 7.685 TOTAL HOURS TOTAL HOURS TOTAL HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C 2151 167 164 2134 1

TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS TOTAL HOURS CALM METEOROLOGICAL PACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED = 2.17 DATE PRINTED: 2005/02/11 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-33

METEOROLOGICAL DATA TABLES BROWNS FERRY NUCLEAR PLANT JANUARY - DECEMBER 2004 TABLE 14 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR SPLIT LEVEL RELEASES (GROUND LEVEL PORTION)

FIRST QUARTER E2-34

m I

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA Tc=-1.9 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1,

2004 -

MAR 31, 2004 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NM SUBTOTAL TOTAL TOTAL TOTAL TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.001 0.000 0.000 0.000 0.000 0.000 0.001 0.000 0.000 0.000 0.000
0. 000
0. 000 0.022 0.074 0.048 0.039 0.005 0.000 0.000 0.000 0.000
0. 000 0.189 0.010 O.000 0.000 0.000 0.000 0.000 0.042 0.005 0.085 0.000 0.000 0.021 0.012 0.008 0.000 0. 000 0.182 0.023 0.032
0. 000 0.000 0.000
0. 000 0.009
0. 000
0. 000 0.000 0.000 0.000 0.006 0.077 0.033 0.009 0.190 0.065 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.013 0.123 0.069 0.090 0.360 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.D00 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.097 0,032 0.000 0.000 0.000 0.000 0.073 0.079 0.134 0.039 0.006 0.021 0.031 0.209 0.102 0.099 0.922 HOURS OF VALID OBSERVATIONS HOURS OF GROUND LEVEL RELEASE HOURS OF STABILITY CLASS A HOURS OF GROUND LEVEL STABILITY CLASS A
  • 2157.000 294.810 19.890 19.890 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2004/05/13 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-35

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2004 - MAR 31, 2004 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 D. 000 0,000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000
0. 002
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 0.002 0.000
0. 000 0.000 0.000 0.000 0.006 0.025 0,009 0.017 0.007 0.000 0.000 0.001 0.000 0.000 0.000 0.064 0.006 0.016 0.005 0.000 0.000 0.000 0.008 0.010 0.028 0.000 0.000 0.003 0.020 0.025 0.008 0.005 0.134 0.032 0.018 0.009 0.000
0. 000
0. 008 0.000 0.000 0.000 0.000 0.000 0.000 0.006 0.054 0.052
0. 045 0.224 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.045 0.000 0.015 0.059 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.046
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.038 0.034 0.013 0.000 0.000 0.014 0.033 0.019 0.047 0.007 0.000 0.003 0.028 0.169 0.060 0.065 0.531 HOURS OF VALID OBSERVATIONS HOURS OF GROUND LEVEL RELEASE HOURS OF STABILITY CLASS B 2157.000 294.810 12.400 11.450 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS B METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2004/05/13 NOTE; TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-36

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=--15 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1,

2004 -

MAR 31, 2004 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW UTW SUBTOTAL TOTAL TOTAL TOTAL TOTAL CALM 0.6-1.4 WIND SPEED(MPH) 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL

0. 000
0. 000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000 0.002 0.000 0.000 0.000 0.000 0.000 0.002
0. 000
0. 000 0.001 0.000
0. 000 0.004 0.004
0. 001 0.012 0.000 0.000 0.000 0.003 0.000 0.000 0.000 0.025 0.006 0.023 0.000 0.003 0.002 0.000 0.009 0.00B 0.00B 0.000 0.008 0.000 0.005 0.007 0.006 0.006 0.092 0.062 0.000 0.014 0.006 0.000 D.000 0.000 0.000 0.000 0.000 0.000 0.000 0.022 0.024 0.025 0.027 0.181 0.023 0.000 0.009 0.000 0.000 0.000
0. 000 0.000
0. 000
0. 000 0.000
0. 000
0. 000
0. 019 0.010 0.032
0. 092 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.090 0.023 0.024 0.009 0.002 0.004 0.013 0.010 0.020 0.000 0.011 0.000 0.031 0.050 0.041 0.066 0.392 HOURS OF VALID OBSERVATIONS HOURS OF GROUND LEVEL RELEASE HOURS OF STABILITY CLASS C HOURS OF GROUND LEVEL STABILITY CLASS C 2157.000 294.810 11.260 8.460 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DBLTA-T BETWEEN 10.03 AND 45.30 METERS

-WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 MIS DATE PRINTED: 2004/05/13 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS H2-37

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

Browns Ferzy Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1,

2004 -

MAR 31, 2004 WIND DIRECTION.

WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5,5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24. 5 TOTAL N

NNE NE BNE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0O.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.001 0.013 0.026 0.048 0.009 0.000 0.000 0.000 0.000 0.000
0. 000 0.002
0. 099 0.045 0.026 0.007 0.020 0O.014 0.027 0.112 0.117
0. 059
0. 011
0. 000 0.017 0.023
0. 000
0. 008 0.013 0.500 0.103 0.145 0.058 0.050 0.007 0.146 0.116 0.019 0.055 0.000 0.010 0.014 0.038 0.027 0.039 0.057 0.885 0.210 0.207 0.134 0.039 0.017 0.086 0.043
0. 000
0. 000 0.000
0. 000 0.037 0.095 0.274 0.466
0. 345 1.952 0.082 0.046 0.076 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0. 000 0.000 0.028 0.366 0.239 0.050 0.887 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.025 0.039 0.000 0.064 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.046
0. 000 0.046 0.440 0.425 0.275 0.110 0.039 0.273 0.297 0.184 0.123 0O.011 0.010 0.068 0.184 0.693 0.837 0.466 4.433 TOTAL HOURS TOTAL HOURS TOTAL HOURS TOTAL HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS D OF GROUND LEVEL STABILITY CLASS D 2157.000 294.810 1151.030 95.620 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BE1WEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED; 2004/05/13 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUtMBERS E2-38

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA Tc= 1.5 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2004 -

MAR 31, 2004 WIND DIRECTION N

NNE NE ENE ESE SE SSE S

SSW SW WSW W

WNW NW NS A SUBTOTAL TOTAL TOTAL TOTAL CALM WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0 000 0. 000

0. 000 0.000
0. 000 0 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.012 0.022 0.021 0.009
0. 019 0.051 0.058 0.070 0.052 0.032 0.014 0.019 0.013 0.003 0.004 0.012 0.413 0.134 0.064 0.066 0.049 0.057 0.088 0.181 0.092 0.127 0.008 0.000 0.021 0.065 0.010 0.021 0.080
1. 064 0.035 0.027 0.055 0.014 0.016 0.059 0.139 0.000 0.103 0.097 0.018 0.008 0.021 0.013 0.060 0.097 0.764 0.096 0.068 0.047 0.007 0.000 0.087 0.259 0.121 0.454 0.174 0.000 0.000 0.008 0.058 0.172 0.084 1.635 0.027 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.018 0.030 0.020 0.141 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.305 0.182 0.189 0.079 0.091 0.285 0.637 0.283 0.783 0.312 0.032 0.049 0.108 0.102 0.288 0.294 4.017 HOURS OF VALID OBSERVATIONS HOURS OF GROUND LEVEL RELEASE HOURS OF STABILITY CLASS E 2157.000 294.810 763.450 86.650 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS B METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 MIS DATE PRINTED: 2004/05/13 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-39

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2004 -

MAR 31, 2004 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NW SUBTOTAL 0.000

0. 000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.006 0.001 0.010 0.000 0.003 0000 0.005 0.003 0.000 0.000 0.000 0.000 0.027 0.011 0.000 0.016 0.001 0.017 0.051 0.134 0.142 0.032 0.000 0.006 0.000 0.003 0.008 0.003 0.023 0.44 6 0.058 0.057 0.008 0.027
0. 045 0.024 0.055 0.140 0.158 0.016
0. 000
0. 000 0.004
0. 000
0. 017 0.045 0.654 0.008 0.023 0.007 0.000 0.000 0.000 0.030 0.025 0.229 0.009 0.000 0.000 0.000 0.000 0.007 0.000 0.338
0. 000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.066 0.635 0.035 0.000 0.000
0. 000
0. 000 0.000 0.008 0.744 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0,000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.076 0.080 0.031 0.029 0.069 0.076 0.228 0.373 1.103 0.060 0.010 0.003 0.007 0.008 0.027 0.076 2.256 TOTAL HOURS OF VALID OBSERVATIONS TOTAL HOURS OF GROUND LEVEL RELEASE TOTAL HOURS OF STABILITY CLASS F TOTAL HOURS OF GROUND LEVEL STABILITY CLASS F 2157.000 294.810 157.890 48.670 METEOROLOGICAL FACILITY:

Browns Perry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 MIS DATE PRINTED: 2004/05/13 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-40

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1,

2004 -

MAR 31, 2004 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=2 4. 5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL

0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.007 0.000 0.008 0.000 0.012 0.049 0.002 0.000

.0.000 0.000 0.000 0.000 0.000 0.000 0,077 0.010 0.004

0. 000 0.002 0.003 0.019 0.043 0.298 0.071 0.015
0. 000 0.000 0.000 0.006 0.002 0.012 0.484 0.019 0.008 0.000 0.000 0.000 0.000*

0.008 0.148 0.123 0.000

0. 000
0. 000
0. 000
0. 000.

0.000 0.012 0.318 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0,086 0.076 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.162 0.000 0.000 0.000

0. 000 0.000 0.000
0. 000 0.000 0.07 5 0.000 O.000 0.000 0.000 0.000 0.000 0.000
0. 075 D.000 0.000 0.000 0.000 0.000 0.000 0.000 D.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.029 0.012 0.007 0.002 0 I 011 0.019 0.063 0.581 0.346 0.015 0.000 0.000 0.000 0.006 0.002 0.023 1.116 TOTAL HOURS TOTAL HOURS TOTAL HOURS TOTAL HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS G OF GROUND LEVEL STABILITY CLASS 0 2157.000 294.810 41.080 24.070 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2004/05/13 NOTE; TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-41

METEOROLOGICAL DATA TABLES BROWNS FERRY NUCLEAR PLANT JANUARY - DECEMBER 2004 TABLE 15 JOINT FREQUENCY DISTREBUTION IN PERCENT FOR SPLIT LEVEL RELEASES (GROUND LEVEL PORTION)

SECOND QUARTER E2-42

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA Tc=-1.9 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1,

2004 - JUN 30, 2004 WIND DIRECTION CALM WIND SPEBD(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7;S-12.4 12.5-18.4 N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.022 0.052 0.023 0.002 0.005

0. 000 0.000 0.000 0.000 0.000 0.103 0.000 0.000
0. 000 0.000 0.000 0O.011 0.031 0.067 0.207 0.070
0. 025 0.008 0. 000 0.000 0.000 0.000
0. 419 0.000 0.004 0.000 0.000 0.000 0.014 0.000 0.0a00 0.010 0.009 0.000 0.002 0.042 0.004 0.006 0.003 0.095 0.000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.007 0.090 0.142 0.087 0.326 0.018 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 O.000 0,000 0.034 0.158 0.049 0.258 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.018 0.004 0.000 0.000 0.000 0.025 0. 053 0.119 0.240 0.081 0.030 0.010 0.049 0.128 0.306 0.139 1.202 HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS A OF GROUND LEVEL STABILITY CLASS A 2137.000 188.410 2S.680 25.680 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETBWEN' 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT

.0.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2004/09/13 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-43

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

Browns Ferry Nuclear Plant PART I OF 2 GROUND LEVEL RELEASE MODE APR 1, 2004 -

JUN 30, 2004 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0O.000 O.000 0.011 0.009 0.022
0. 000 0.003 0O.000 0.000 0.000 0.000 0.000 0.044 0.000 0.000 0.000 D. 000
0. 000 0.014 0.013 0.021
0. 000 0.101 0.029 0.037 0.002
0. 000 0 000 0.000 0.217 0.006 0.000 0.000 0.000 0.002 0.007 0.000 0.000 0.009 0.036 0.000
0. 022 0.014 0.006 0.000 0.000 0.103 0.013 0.000 0.013
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.021 0.044 0.038
0. 129 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.009 0.009 0.019 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.000 O.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000
0. 000 0.000
0. 000
0. 019 0.000 0.013 0.000 0.002 0.022 0.024 0.030 0.031 0.138 0.031 0.059 0.016 0.027 0.053 0.048 0.512 HOURS OF VALID OBSERVATIONS HOURS OF GROUND LEVEL RELEASE HOURS OF STABILITY CLASS B HOURS OF GROUND LEVEL STABILITY CLASS B 2137.000 188.410 10.940 10.940 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2004/09/13 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-44

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1,

2004 - JUN 30, 2004 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CAL1 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 O. 000 0.000 0.000 0.008 0.041 0.044 0.008 0.000 0.000 0.000 0.000 0.000 0.000 0.101 0.000 0.000 0.001 0.000 0.000 0.006 0.010 0.000 0.015 0.040 0.007 0.040

0. 002 0.000 0.000 0.000 0.120 0.007 0.000 O.000 0.000 0.000 0.007 O.000 0.000 0.025 0.014 O.000 0.016 0.002 0.010 0.004 0.007 0.092 0.008 0.006 0.008 0.000
0. 000
0. 000 0.000
0. 000
0. 000 0.022
0. 000 0.007
0. 000 0.04 3 0.036 0.064 0.194 0.000 0.009 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.009 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.000
0. 0oo
0. 000
0. 000
0. 000
0. 000 0.000 0.015 0,015 O.009 0.000 0.000 0.013 0.018 0.041 0.083 0.084 0.007 0.063 0.004 0.052 0.041
0. 071 0.516 TOTAL HOURS TOTAL HOURS TOTAL HOURS TOTAL HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS C OF GROUND LEVEL STABILITY CLASS C 2137.000 188.410 15.700 11.030 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED; 2004/09/13 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-45

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1,

2004 - JUN 30, 2004 WIND DIRECTION WIND SPEED(MPHI CALM 0.6-1.4 1.5-3.1 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE B

ESE SE SSE S

SSW SW WsW W

WNW NW NNW SUBTOTAL 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.005 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.005 0.000 0.001 0.000 0.000 0.008 0.030 0.145 0.188 0.230 0.135 0.021 0.005 0.001
0. 000
0. 000 0.000 0.765 0.024 0.026 0.001 0.006 0.000 0.111 0.102 0.044

.0.239 0.292 0.040 0.083 0.056 0.013 0.006 0.008 1.052 0.055 0.088 0.022 0.005 0.000 0.03S 0.000 0 000

0. 068 0.137
0. 000 0.058 0.083 0.025 0.041 0.066 0.683 0.068
0. 069 0.071 0.000 0.000
0. 000
0. 000 0.000 O.000 0.000 0.000 0.000 0.006 0.083 0.165 0.083 0.546 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.172 0.000 0.172 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000
0. 000 0.000 0, 000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.147 0.183 0.094 0.011 0.008 0.176 0.252 0.233 0.537 0.564 0.061 0.146 0.146 0.122 0.384 0.158 3.222 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS D OF GROUND LEVEL STABILITY CLASS D 2137.000 188.410 1297.850 68.850 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2004/09/13 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-46

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1, 2004 - JUN 30, 2004 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5,5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.002 0.000 0.000 0.000 0.003 0.008 0.000 0.000 0.000 0.000 0.000 0.000 0.013 0.002 0.003 0.001 0.011 0.091 0.198 0.094 0.083 0.237 0.094

0. 009 0.004 0.008
0. 000 0.002 0.024 0.862 0.034 0.019 0.023 0.017 0.049 0.182 0.030 0.018 0.233 0.141
0. 000 0.009 0.029
0. 00.

0.025 0.065 0.884 0.016 0.012 0.024 0.000 0.00o7 0.000 0.000 0,000 0.096 0.018 0.000 0.000 0.000 0.006 0.050 0.044 0.273 0.016 0.008 0.007 0.000 0.000 0.000 0,000 0.000 0.000 0.000 0.000 0.000 0.030 0.007 0.091

0. 017 0.177 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.080 0.000 0.080 0.000 0.000 0.000 0.000 0.000 0.000 0000 0.000 0000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000
0. 000 O.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.069 0.042 0.055 0.028 0.149 0.381 0.124 0.101 0.569 0.262 0.009 0.013 0.068 0.022 0.248 0.150 2.289 TOTAL HOURS OF VALID OBSERVATIONS TOTAL HOURS OF GROUND LEVEL RELEASE TOTAL HOURS OF STABILITY CLASS E TOTAL HOURS OF GROUND LEVEL STABILITY CLASS E 2137.000 188.410 620.630 48.920 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2004/09/13 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-47

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA Tc= 4.0 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1, 2004 - JUN 30, 2004 WIND DIRECTION N

NNE NE ENE ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.6-1.4 WIND SPRED(MPH) 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.006 0.000 0.000 0.003 0.000 0.015 0.003 0.002 0.003 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.031 0.033 0.010 0.000 0.013 0.063 0.044 0.025 0.022 0.051 0.002
0. 000
0. 002
0. 000
0. 000
0. 008 0.015 0.289 0.043
0. 057
0. 007 0.018
0. 022
0. 015 0.000
0. 000
0. 018
0. 000 0.000
0. 000
0. 000
0. 000
0. 025
0. 073
0. 279 0.009 0.017 0.030 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.037 0.026 0.119 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000
0. 000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.028 0.028 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 O.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000 0.090
0. 084 0.038 0.033 0.085 0.074 0.029 0.024 0.071 0.002 0.000 0.002 0.000 0.000 0.071 0.142 0.746 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS F OF GROUND LEVEL STABILITY CLASS F 2137.000 188. 410 132.740 15.940 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 IETER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 MIS DATE PRINTED: 2004/09/13 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-48

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

Browns Ferry Nuclear Plant PART I OF 2 GROUND LEVEL RELEASE MODE APR 1, 2004 -

JUN 30, 2004 WIND DIRECTION WIND SPEED(MPH) 1.5-3.4 3.5-5.4 5.5-7.4 N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL CALM 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.6-1.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 0.007 0.014 0.000 0.015 0.000 0.001 0.000 0.005 0.007 0.002 0.002 0.010 0.022 0.006 0.024 0.065 0.006 0.039 0.000 0.000 0.000 0.000 0.000

0. 000 0,000 0.000 0.000 0.000 0.000 0.000 0.000 0.013 0.069 0.169
0. 027 0.036 0.000
0. 000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.021 0.083 0.000 0.008 0.000 0.000 0.000 a.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0. 000 0. 000 0.008
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.047 0.060 0.001 0.005 0.009 0.012 0.028 0.089 0.045 0.000 0.000 0.000 0.000
0. 000 0.000 0.034 0.330 TOTAL TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS G OF GROUND LEVEL STABILITY CLASS G 2137.000 188.410 33.4 60 7.050 METEOROLOGICAL FACILITY Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATB PRINTED; 2004/09/13 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-49

METEOROLOGCAL DATA TABLES BROWNS FERRY NUCLEAR PLANT JANUARY - DECEMBER 2004 TABLE 16 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR SPLIT LEVEL RELEASES (GROUND LEVEL PORTION)

THIRD QUARTER E2-50

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-l.9 C/l00 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2004 - SEP 30, 2004 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNWT SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000*
0. 000 0.000 0.000 0.000 0.022 0.015 0.034 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.071 0.000 0.000 0.000
0. 000 0.000 0.038 0.067 0.038 0.018 0.026
0. 000 0.000 0.000
0. 000 0.000
0. 000 0.187 0.000 0.005 0,000 0.000 0.002 0.169 0.034 0,000 0.000 0.000 0.000 0.000 0.000 0.002 0.000 0.000 0.213 0.081 0.104 0.015 0.000 0.000 0.046
0. 000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000 0.005
0. 000 0.044 0.294 0.000 0.028 0.009 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.045 0.009 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 O.000 0.000 0.000 O.000 0.000 0O.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.081 0.138 0.023 0.000 0.002 0.254 0.124 0.053 0.052 0.026 0.000 0.000 0.000 0.006 0.045 0.053 0.856 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS A OF GROUND LEVEL STABILITY CLASS A 2185.000 181.330 18.710 18.710 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2004/12/21 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED PROM UNROUNDED NUMBERS E2-51

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/l00 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2004 - SEP 30, 2004 WIND DIRECTION WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4

18. 5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.00 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.005 0.000 0.002 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.006 0.000 0.000 0.000 0.000 0.002 0.021 0.010

0. 001
0. 000
0. 000 0.004
0. 001 0.010
0. 000 0.000
0. 000 0.049 0.000 0.000 0.005 0.000 0.009 0.014 0.000 0.000 0.000 0.000 0.000 0.000 0.005 0.012 0.001 0.011 0.058 0.081 0.054 0.022 0.000 0.000 0.000 0.000 0.000 0.000 0.000 O.000 0.000 0.012 0.005 0.037 0.04 5 0.256 0.033 0.027 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.009 0.018 0.000 0.087 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0,000
0. 000 0.000 0.000
0. 000 0,000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 O.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.115 0.081 0.026 O.000 0.011 0.034 0.014 0.001 0.002 0.000 0.004 0.001 0.027 0.026 0.056 0.057 0.455 HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS B OF GROUND LEVEL STABILITY CLASS B 2185.000 181.330 9.950
9. 950 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2004/12/21 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-52

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C1100 M)

Browns Perry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2004 - SEP 30, 2004 WIND DIRECTION CALM WIND SPEED(NPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

-249. 5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0.000 0.000 0.000 0.000

0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.005 0O.000
0. 014 0.000
0. 000 0.000 0.000
0. 000
0. 000 0.000
0. 000 0.000 0.001
0. 000 0.000 0.026 0.004
0. 000
0. 000
0. 000 0.006 0.002 0.014 0.000 0.001 0.002 0.041 0.019 0.012 0.003 0.000 0.016 0.000 0.000
0. 000 0.000 0.000 0.003 0.030 0.004 0.023
0. 019 0.040 0.026 0.005 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.012 0.013 0.030 0.041 0.000 0.000 0.000 O.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.008 0.018 0.010 0.000 O.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.000
0. 000
0. 000
0. 000
0. 000 0.000
0. 000
0. 000
0. 000 0.081 0.045 0.03.8 0.004 O.000 0.043 0.009 0.000 0.014 0.000 0.006 0.005 0.056 0.025 0.073 0.072 SUBTOTAL
0. 000 0.000
0. 019 0.056 0.171 0.168 0.036 0.000 0.000 0.451 TOTAL HOURS OF VALID OBSERVATIONS TOTAL HOURS TOTAL HOURS TOTAL HOURS OF GROUND LEVEL RELEASE OF STABILITY CLASS C OF GROUND LEVEL STABILITY CLASS C 2185.000 181.330 23.080 9.850 METEOROLOGICAL FACILITY:

Browns Fcrry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN

10. 03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2004/12/21 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2 -53

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0,5 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2004 -

SEP 30, 2004 WIND DIRECTION CALM WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000
0. 000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.004 0.000 0.000 0.005 0.030 0.056 0.048 0.072 0.094 0.002 0.004 0.000 0.000 0.000 0.000 0.315 0.060 0.020 0.002 0.001 0.032 0.081 0.034 0.000 0.025 0.034 0.011 0.032 0.038 0.007 0.008 0.023 0.410 0.122 0,094 0.024 0.020 0.059 0.131
0. 000 0.000 0.000 0.000 0.000 0.006 0.056 0.040 0.077 0,0B6 0.715 0.122 0.058 0.029 0.007 0.000 0.033 0.000 0.000 0.000 0.000 0.000 0.008 0.025 0.058 0.137 0.096 0.573 0.021 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0. 000 0.000 0.000 0.000 0.000 0.103 0.063 0.233 0.137 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.168 0.000 0.351 0.000 0.137 0.000 0.000 0.000 0.000 0.o000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000
0. 000 0.137 0.4 63 0.358 0.101 0.028 0.097 0.276 0.090 0.048 0.097 0.128 0.013 0.051 0.119 0,105 0.495 0.268 2.736 0.000 0.000 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASP OF STABILITY CLASS D OF GROUND LEVEL STABILITY CLASS D 2185.000 181.330 1172.570 59.790 METEOROLOGICAL FACILITY; Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 H/S DATE PRINTED: 2004/12/21 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-54

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-0.5< DELTA T<= 1.5 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2004

- SEP 30, 2004 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4

>=24. 5 TOTAL 0.000 0.000 0.000 0.005 0.003 0.003 0.003 0.000 0.000 0.005 0.000 0.000 0.000 0.000 0.000 0.000 0.020 0.068 0.009 0.009 0.02S

0. 059 0.101 0.077 0.048 0.036 0.037 0.010 0.000 0.005 0.000 0.005 0.039 0.528 0.128 0.074 0.022 0.025 0.154 0.181 0.015 0.000 0.000 0.007 0.000 0.000 0.025 0.003 0.016
0. 091 0.741 0.063 0.116 0.051 0.006 0.021 0.175 0.000 0.000 0.000 0.000 0.000 0.000 0.016 0.000 0.035 0.068 0.551 0.009 0.050 0.025 0.000 0.000 0.018
0. 000
0. 000
0. 000
0. 000 0.000
0. 000 0.000
0. 000 0.000 0.023 0.126 0.000 0.000 0.000 0.000 0.000 0.000 0. 000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.040 0.040 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0,000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.268 0.249 0.107 0.061 0.237 0.478 0.095 0.048 0.036 0.049 0.010 0.000 0.04 5 0.003 0.056 0.261 2.005 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS E OF GROUND LEVEL STABILITY CLASS E 2185. 000 181. 330 669.340 43,.810 METEOROLOGICAL FACILITY:

Browns Perry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2004/12/21 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED PROM UNROUNDED NUMBERS E2 -55

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2004 -

SEP 30, 2004 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000

.0.000 O.000 0.000

0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.005 0.000 0.000 0.000 0.001 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.006 0.193 0.036 0.029 0.082 0.088 0.033 0.000 0.000 0.006 0.013 0.000 0.000
0. 000
0. 000 0.000 0.068 0.549 0.349 0.137 0.026 0.079 0.140 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.007 0.038 0.776 0.000 0.015 0.015 0.000 0.008 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.038 0.000 0.009 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 0oo 0.000 0.000 0.000 0.000 0.009 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000 0.000
0. 000
0. 000 0.000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.o000
0. 000
0. 000 0.542 0.197 0.071 0.166 0.237 0.033 0.000 0.001 0.006 0.013 0.000 O.000 0.000 0.000 0.007 0.106 1.379 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS F OF GROUND LEVEL STABILITY CLASS F 2185.000 181.330 241.310 30.130 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2004/12/21 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-56

SPLIT JOIN? PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1,

2004 -

SEP 30, 2004 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

ssW SW WSW W

WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.002 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.002 0.086 0.037 0.017 0.030 0.006 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.o000 0.000 0.000 0.006 0.182 0.157 0.008 0.007 0.036 0.018 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000 0.000 0.007 0.232 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.243 0.047 0.024 0.065 0.024 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.013 0.416 HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS C OF GROUND LEVEL STABILITY CLASS G 2185.000 181,330
50. 040 9.090 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2004/12/21 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-57

METEOROLOGICAL DATA TABLES BROWNS FERRY NUCLEAR PLANT JANUARY - DECEMBER 2004 TABLE 17 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR SPLIT LEVEL RELEASES (GROUND LEVEL PORTION)

FOURTH QUARTER E2-58

SPLIT JOINT PERCENTAGE FREQUENCIBS OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2004 -

DEC 31, 2004 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24. 5 TOTAL N

NNE NE ENE B

BSE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL

0. 000 0.000 0, 000 0.000 0.000 0.000 0.000 0.000 0.000 0O000 0.000 0.000 0.000 0.000 I 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 O.000 0.000 O.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.001 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0. 000 0.000 0.001 0.000 0.000 0.000 0.000
0. 000 0.002 0.060 0.044
0. 080 0.013 0.000 0.000
0. 000
0. 000 0.000 0.000 0.200 0.005 0.003 0.000 0.000 O.000 0.038 0.032 0.028 0.033 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.140 0.025 0.009 0.000 0.000 0.000 0.008 0.000 0.000
0. 000
0. 000
0. 000
0. 000 0.031 0.000 0.015 0.022 0.111 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.010 0.033 0.036 0.078 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.033 0.033
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.030 0.013 0.000 0.000 0.000 0.049 0.094 0.073 0.113 0.013 0.000 0.000 0.031 0.010 0.048 0.091
0. 563 HOURS OF VALID OBSERVATIONS HOURS HOURS HOURS OF GROUND LEVEL RELEASE OF STABILITY CLASS A OF GROUND LEVEL STABILITY CLASS A 2135. 000 261.160 13.470 12.030 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2005/02/11 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-59

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA Tc=-1.7 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2004 -

DEC 31, 2004 WIND DIRECTION WIND SPEBD(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24. 5 TOTAL N

NNE NE ENS E

ESE SE SSE S

SSW SW WSW W

hWN NW NlW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.0,00 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000
0. 000 0.000

. 000 0.ODO 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.005 0.004 0.017 0.012 0.000 0.000 0.003 0.000
0. 000
0. 000 0.000 0.041 0.022 0.001 0.000 0.000 0.000 0.024 0.010 0.025 0.032 0.000 0.000 0.000 0.000 0.003 0.000 0.000 0.118 0.029 0.009 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.008
0. 000 0.045 0.018 0.110 0.000 0.009 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.103 0.000 0.112 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000
0. 000
0. 000
0. 000
0. 000 0.052 0.020 0.000 0.000 0.000 0.029 0.019 0.042 0.044 0.000 0.000 0.003 0.008 0.003 0.148 0.01O 0.381 TOTAL HOURS OP VALID OBSERVATIONS TOTAL TOTAL TOTAL HOURS HOURS HOURS OP GROUND LEVEL RELEASE OP STABILITY CLASS B OP GROUND LEVEL STABILITY CLASS B 2135.000 261.160 8.130 8.130 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2005/02/11 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-60

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

Browns Ferry Nuclear Plant PART I OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2004 -

DEC 31, 2004 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

Ssw SW WSW W

WNW NW NNW SUBTOTAL CALM 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000
0. 000 0.000 0.005 0.005 0.000 0.000 O.000
0. 000 0.000 0.000 0.000 0.000 0.010 0.000 0.000 0.000
0. 000
0. 000 0.005 0.006 0.019 0.017 0,016 0.005 0.012 0.000 0.000 0.000 0.000 0.016 0.000 0.000 0.000 0.000 0.054
0. 009 0.000 0.009 0.000 0.009 0.000 0.000 0.002 0.012 0.002
0. 007 0.007 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.014 0.020 0.050 0.012 0.110 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.021 0.031 0.052 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000
0. 000
0. 000
0. 000 0.023 0.007 0.000 0.000 0.000 0.059 0.021 0.023 0.026 0.016 0.015 0.012 0.014 0.022 0.083 0.045 0.366 0.080 0.114 TOTAL HOURS TOTAL HOURS TOTAL HOURS TOTAL HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS C OF GROUND LEVEL STABILITY CLASS C 2135.000 261.160 12.560 7.820 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2005/02/11 NOTE-TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-61

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2004 -

DEC 31, 2004 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW U TW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.003 0.004 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.007 0.000 0.000 0.000 0.000 0.011 0.011 0.037 0.069 0.075 0.008 0.012 0.001 0.000 0.000 0.000 0.000 0.225 0.019 0.008 0.002 0.016 0.031 0.159 0.169

0. 389 0.218 0.034 0.036 0.042 0.034 0.003 0.004 0.016 1.181 0.024 0.024 0.014 0.001 0.034 0.184 0.378 0.151 0.142 0.018 0.042 0.058 0.170 0.044 0.046 0.025 1.356 0.151 0.178 0.023
0. 008 0.000 0.065 0.068 0.000 0.142 0.035 0.000 0.017 0.230 0.118 0.310 0.098 1.444 0.000 0.009 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.036 0.394 0.330 0.058 0.828 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.114 0.036 0.000 0.150
0. 000
0. 000
0. 000 0.000
0. 000
0. 000
0. 000
0. 000 0.000
0. 000
0. 000 0.000 0.000
0. 000
0. 000 0.000
0. 000 0.195 0.220 0.039 0.025 0.076 0.421 0.657 0.609 0.578 0.095 0.090 0.118 0.469 0.674 0,726 0.198 5.189 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS D OF GROUND LEVEL STABILITY CLASS D 2135.000 261.160 1121.500 110.790 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 MIS DATE PRINTED: 2005/02/11 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-62

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2004 -

DEC 31, 2004 WIND DIRECTION N

NNE NB ENE BE ESE SE SSE S

SSW SW WSW W

WNW NW U

LNW SUB5TOTAL CALM WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24. 5 TOTAL O. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.004 0.000 0.000 0.000 0.000 0.000 0.000 I0.000 0.018 0.008 0.005 0.031 0.029 0.081 0.140 0.143 Oi152 0.039 0.011 0.008 0.007 0.000 0.002
0. 003 0.066
0. 058 0.061 0.041 0.148 0.24 9 0.110 0.446 0.410
0. 021 0.031
0. 019
0. 069
0. 013 0.009 0.042 1.793 0.026 0.021 0.037 0.020 0.030 0.169 0.027 0.146 0.211 0.017
0. 009 0008 0.006 0.037 0.040 0.021 0.823 0.017 0.093 0.030 0.000
0. 000 0.000 0.000
0. 000 0.286 0.029
0. 000
0. 000
0. 008
0. 000
0. 076 0.044
0. 583 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000 0 000 0.000
0. 000 0.000 0.127.

0.179 0.133 0.092 0.207 0.498 0.276 0.734 1.063 0.106

0. 051 0.036 0.090 0.050 0.127 0.110 3,880 0.004 0.677 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS, OF GROUND LEVEL RELEASE OF STABILITY CLASS E OF GROUND LEVEL STABILITY CLASS E 2135.000 261.160 774.340 82.840 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EPFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2005/02/11 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-63

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 H)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2004 -

DEC 31, 2004 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALK 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.022 0.030 0.007 0.000 0.000 0.000 0.000 O.000 0.000 0.000 0.060 0.018 0.009 0.013

0. 022 0.065 0.083 0.153 0.128 0.074 0.006
0. 000
0. 000 0.002 0.003 0.005
0. 009
0. 591 0.068 0.044 0.017 0.016 0.078 0.053 0.050 0.168
0. 043 0.000 0.000 0.000 0.000 0.004 0.008 0.022 0.571 0.008 0.024 0.007 0.015 0.000 0.000 0.000 0.020 0.016 0.000 0.000 0.000 0.000 0.000 0.007 0.008 0.105
0. 000
0. 009 0.000 0.000
0. 000
0. 000
0. 000
0. 000
0. 037 0.000 0.000
0. 000
0. 000
0. 000
0. 000 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 D.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.095 0.086 0.037 0.053 0.143 0.136 0.226 0.347 0.176 0.006 0.000 0.000 0.002 0.007 0.020 0.040 1.373 HOURS HOURS HOURS HOURS OP VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS F OF GROUND LEVEL STABILITY CLASS F 2135.000 261.160 166.600 29.320 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2005/02/11 NOTE:

TOTALS AND SUBTOTALS ARE OBTA1NED FROM UNROUNDED NUMBERS E2-64

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2004 -

DEC 31, 2004 WIND DIRECTION WIND SPEED(MPH)

CALM 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24. 5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.002 0.000 0.000 0.000 0.000 0.007 0.020 0.018 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.005 0.005 0001 0.007 0.006 0.000 0.020 0.173 0.030 0.000

0. 000 0.000 0.000 0.000 0.000 0.016 0.264 0.022 0.018 0.000 0.015 0.003 0.000 0.000 0.047 0.011 0.000 0.000 0.000 0.000 0.000 0.007 0.023 0.146 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.015 O.000 0.000 0.000 O.000 0.000 0.000 0.007 0.022 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000
0. 000
0. 000
0. 000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.0OO
0. 000 0.000 0.000
0. 000
0. 000 0.000 0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.029 0.023 0.001 0.023 0.008 0.007 0.039 0.238 0.056 0.000 0.000 0.000 0.000 0.000 0.007 0.047 0.479 TOTAL HOURS TOTAL HOURS TOTAL HOURS TOTAl HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OP STABILITY CLASS G OF GROUND LEVEL STABILITY CLASS 6 2135.000 261.160 38.400 10.230 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STA8}LITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 MIS DATE PRINTED: 2005/02/11 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-65

METEOROLOGICAL DATA TABLES BROWNS FERRY NUCLEAR PLANT JANUARY - DECEMBER 2004 TABLE 18 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR SPLIT LEVEL RELEASES (ELEVATED PORTION)

FIRST QUARTER E2-66

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/1OO M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE JAN 1,

2004 -

MAR 31, 2004 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

-=24. 5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WsW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0,000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000 O.000
0. 000
0. 000
0. 000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000*

0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 O.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0,000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 O.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL HOURS OF VALID OBSERVATIONS TOTAL HOURS OF ELEVATED RELEASES TOTAL HOURS OF STABILITY CLASS A TOTAL HOURS OF ELEVATED STABILITY CLASS A 2157.000 1862.190 19.890 0.000 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DE1TA-T BETWEEN 4S.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2004/05/13 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-67

SPLIT JOINT PERCZNTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELtA T<=-1.7 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE JAN 1,

2004 -

MAR 31, 2004 WIND DIRECTION CALM 0.6-1.4 WIND SPEED(MPH) 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24. 5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

SWm NW NNW SU8TOTAL

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0O.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000
0. 000 0.000 0.00O 0.000 0.000 0.000 0.000 0.044 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.044 0.000 0.000
0. 000 0.000 0,000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0;000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.044 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.044 TOTAL HOURS OF VALID OBSERVATIONS TOTAL HOURS OF ELEVATED RELEASES TOTAL HOURS OF STABILITY CLASS B 2157.000 1862.190 12.400 TOTAL HOURS OF ELEVATED STABILITY CLASS B 0.950 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED; 2004/05/13 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-68

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR I STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2004 -

MAR 31, 2004 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTrAL CALM

0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0 000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0,000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000
0. 000
0. 000
0. 000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 046
0. 000 0.000 0.000 0.000
0. 000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.043 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.043 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.040 0.000 0.000 0.000 0.000 0.040 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0,000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0,000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.043 0.000 0.000 0.046 0.000 0.040 0. 000 0.000 0.000 0.000 0.130 TOTAL TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS C OF ELEVATED STABILITY CLASS C 2157.000 1862.190 11.260 2.800 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTIONJ MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2004/05/13 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-69

SPLIT JONT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRBCTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

Browns Ferry NUclear Plant PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2004 -

MAR 31, 2004 WIND DIRECTION WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE RNE ESE SE SSE S

SSW SW WSW W

WNW NW NNW

0. 000
0. 000
0. 000 O 000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 O.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 O.000 0.000
0. 000 0.046 0.000 0.046 0.046 0.139 0.093 0.046 0.185 0.185 0.417 0.325 0.139 0.232 0.325 0.046 0.093 0.093 0.093
0. 000 0.371 0.185 0.464 0.278 0.325 0.742 0.278 0.464 0.464
0. 325 0.185 0.464 0.278 0.464 0.278 0.487 0.703 0.400 0.314 0.446 0.407 0.675 0.179 0.360 0.093 0.225 0.269 0.529 0.401 0.357 0.355 2.025 2.199 1.146 0.773 0.165 0.403 0.614 0.771 0.801 0.967 0.286 0.455 0.860 1.993 1.739 1.741 1.815 1.019 0.639 0.000 0.114 0.415 0.452 0.905 1.991 0,638 0.300 0.149
0. 567 1.954 2.450 1.770 0.262 0.000 0.073 0.000 0.000 0.031 0.156 0.098 0.418 0.274 0.033 0.000 0.055 0.518 0.242 0.240 0.012 0.000 0.000 0.000 0.000 0.000 0.006 0.000 0.02 0 0.008
0. 000
0. 000 0.000 0.000
0. 007 0.000 4.648 4.339 2.583 1.643 1.049 1.812.

2.831 2.650 4.378 2.581 1.401 1.383

2. 521 5.236 5.398 4.477 SUBTOTAL 0.000 0.093 2.503 S.563 6.200 16.938 15.178 2.400 0.054 48.930 TOTAL HOURS OF VALID OBSERVATIONS TOTAL TOTAL TOTAL HOURS HOURS HOURS OF ELEVATED RELEASES OF STABILITY CLASS D OF ELEVATED STABILITY CLASS D 2157.000 1862.190 11 51.030 1055.410 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 MIS DATE PRINTED: 2004/05/13 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-70

SPLIT JOINT PERCENTAGE FREQUENCIES OP WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5.c DELTA T<= 1.5 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE JAN 1,

2004 -

MAR 31, 2004 WIND DIRECTION WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24. 5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0,000 0.000 0.1000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.325 0.000 0.13 9 0.04 6 0.093 0.000 0.139 0.093 0.139 0.185 0.185 0.185 0.093 0.046 0.232 0.093 0.325 0.139 0.185 0.185 0.325 0.417 0.556 0.464 0.417

0. 4.17 0.325 0.510 0.278 0.325 0.139 0.232 0.222 0.533 0.315 0.310 0.268 0.358 0.803 0 708 0.317 0.260 0.449 0.413 0, 663 0.314 0.180 0.448 0.737 1.024 0.813 0.486 0.330 1.343 1.673 1.458
0. 887
0. 520 0.418 0.210 0.540 0.370 0.323 0.608 0.152 0.151 0.114 0.038 0.000 0.568 1.017 0.720 1.057
0. 074 0.149 0.000 0.038 0.075 0.262 0.265 0.000 0.000 O.000 O.000 0.000 0.026 0.161 0.544 0.210 0.012 0.000 0.037 0.029 0.000 0.015 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.004 0.014 0.022 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 1.759 1.847 1.566 1.066 1.015 2.713 4.353 4.046 3 050 1.468 1.526 1.402 1.640 1.130 1.152 1.645 SUBTOTAL 0.000 0.093 1.994 5.239 6.560 11.737 4.681 1.034 0.040 31.377 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS E OF ELEVATED STABILITY CLASS E 2157.000 1862.190 763.450 676.800 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETnEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2004/05/13 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-71

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2004 - MAR 31, 2004 WIND DIRECTION WIND SPEED(MPH)

CALM 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE BN ESE SE SSE SB SSW SW WSW WNW NW NNW SUBTOTAL 0.000 0.000 0.000

0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 I 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.093 0.000 0.093 0.046
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.232 0.000 0.093 0.093 0.093 0.046 0.000 0.000 0.093 0.139 0.093 0.139 0.093 0.046 0.046-
0. 000
0. 000 0.974 0.000 0.044 0.091 0.091 0.224 0.046 0.087 0.222 0.219 0.137 0.178 0.136 0.133 0.044 0.045 0.044 1.741 0.163 0.124 0.083 0.043 0.369 0.327
0. 366 0.041 D.043 0.083 0.042 0.000 0.000 0.000 0.000 0.206 1.887 0.000 0.000 0.000 0.038 0.000 0.000 0.191 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.229 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.163 0.260 0.359 0.266 0.732 0.420 0.644 0.356 0.401 0.312
0. 359 0.229 0.179 0.090 0.045 0.250 5.064 TOTAL TOTAL TOTAL TOTAL HOURS OF VALID OBSERVATIONS HOURS OF ELEVATED RELEASES HOURS OF STABILITY CLASS F HOURS OF ELEVATED STABILITY CLASS F 2157.000 1862.190 157.890 109.220 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2004/05/13 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-72

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 Ml Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2004 -

MAR 31, 2004 WIND DIRECTION WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.174 0.000 0.000 0.087 0.000 0.000 0.000 0.000 0.000 0.000 0.261 0.000 0.000 0.121 0.118 0.000 0.000 0.288 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 528 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.000
0. 000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.121 0.118 0.000 0.000 0.4 62 0.000 0.000 0.087 0.000 0.000 0.000 0.000 0.000 0.000 0.789 HOURS OF VALID OBSERVATIONS HOURS OF ELEVATED RELEASES HOURS OF STABILITY CLASS G HOURS OF ELEVATED STABILITY CLASS G 2157.000 1862.190 41.080 17.010 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFPLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2004/05/13 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-73

METEOROLOGICAL DATA TABLES BROWNS FERRY NUCLEAR PLANT JANUARY - DECEMBER 2004 TABLE 19 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR SPLIT LEVEL RELEASES (ELEVATED PORTION)

SECOND QUARTER E2-74

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2004 - JUN 30, 2004 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 O. 000 0.000 0.000 0.000 0.000 WIND SPEED(MPH) 1.5-3.4 3.5-5.4 5.5-7.4 0.6-1.4 0.000 0.000 0O.000 0.000 0.000 0.000 0.000 0.000 0O.000 0.000 0.000 0.000 0.000

0. 000 0.000
0. DO0
0. 000 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0, 000 0.000 0.000 0.000
0. 0o0 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.o000
0. 000 TOTAL HOURS TOTAL HOURS TOTAL HOURS TOTAL HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS A OF ELEVATED STABILITY CLASS A 2137.000 1948.590 25.680 0.000 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2004/09/13 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-75

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2004 - JUN 30, 2004 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4.

1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL

0. 000 O. 000 0.000
0. 000 0.000 0O.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 O.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000
0. 000 0.000
0. 000 0. 000 0.000 0 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS B 2137.000 1948.590 10.940 TOTAL HOURS OF ELEVATED STABILITY CLASS B 0.000 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2004/09/13 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-76

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

Browns Perry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2004 - JUN 30, 2004 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.094 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.045
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.041 0.000 0.000 0.000 0.000 0.000 0.041 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.038 0.000 0.000 0. 000 0.000 0.000 0.000 0.000 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0. 000 0.000 0.000 0.000 0,000 0.000 0.000 0.000 0.000 0.o000
0. 000 0.000
0. 000 0.000 0.000 0 I 000 0.000
0. 000
0. 000 0.000
0. 000
0. 000
0. 000
0. 000 0.045 0.000 0.000 0.000 0.000 0.000 0.047 0.038 0.000
0. 000 0.088 0.000
0. 000 0.000 0.000 0.000 0.219 0.038 0.000 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASB9 OF STABILITY CLASS C OF ELEVATED STABILITY CLASS C 2137.000 1948.590 15,700 4.670 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2004/09/13 NOTE:

TOTALS AND SUB'OTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-77

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE APR 1,

2004 -

JUN 30, 2004 WIND DIRECTION WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24. 5 TOTAL N

NNE NE ENE E

ESE SE SSE S

sSW SW WSW W

WNW NW NN 0.000 0O000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.047 0.047 0.000 0.000 0.000 0.000 0.000 0.047 0.094 0.047 0.047 0.047
0. 094 0.936 0.562 0.936 0.608 0.749 0.281 0.140 0.094
0. 047
0. 000 0.281 0.32B 0.000 0.094 0.187 0.281 1.123 0.936 0.983 1.310 1.263 0.983 1.170 0.374 0.140 0.094 0.358 0.449 0.04 6 0.136 0.090 0.183 1.092 1.169 1.529 1.117 1.320 1.036 0.865 0.816 0.678 0.496 0.819 1.238 0.653 0.042 0.000 0.371 1.730 2.571 2.895 2.825 2.292 1.045 1.121 1.188 1.458 1.169 0.500 0.304 0.154 O.000 0.000 0.000 0.613 1.677 1.601 1.593 0.078 0.000 O.000 0.463 0.992 0.796 0.064 0.033 0.000 0.000 0.000 0.000 0.000 0.160 0.401 0.340 0.016 0.000 0.000 0.000 0.481 0,036 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 2.067 2.445 0.900 0.319 0.324 0.928 5.494 7.121 8.345 7.839 5.766 3.344 3.296 2.935 3.795 2. 591 SUBTOTAL 0.000 0.140 4.726 9.546 11.380 21.417 8.771 1.530 0.000 57.511 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS D OF ELEVATED STABILITY CLASS D 2137.000 1948.590 1297.850 1229.000 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2004/09/13 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-78

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2004 -

JUN 30, 2004 WIND DIRECTION WIND SPEED(MPHI 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SW SW WSW W

WNW NW NNW 0.000 0.000 O. 000 0.000

0. 000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.094 0.000 0.047 0.000 0.047 0.047 0.000 0.094 0.000 0.000 0.000 0.000 0.047 0.094 0.140 0.094 0.047 0.140 0.140 0.234 0.234 0.187 0.702 0.421 0.515 0.374 0.140 0.047 0.094 0.094 0.281 0.234 0.234 0.468 0.094 0.421 0.281 0.655 0.562 0.749 0.749 0.328 0.421 0.094.

0.094 0.187 0.319 0.179 0.044 0.406 0.272 0.716 0,363 0.405

0. 545 0.591 0.180 0.225 0.317 0.047 0.088 0.313 1.037 0.659 0.329 0.169 0.168 0.993 0.784 0.701 1.295 0.975 0.293 0.168 0.256 0.160 0.644 0.657 0.190 0.078 0.000 0.000 0.000 0.000 0.115 0.265 0.457 0.421 0.000 0.000 0.000 0.000 0.499 0.307 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.024 0.131 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000
0. 000
0. 000
0. 000 0. 000 0. 000
0. 000 0.0 O 0.000
0. 000
0. 000 0.000 1.967 1.290 0.747 1.183 0.721 2.365 1.824 2.284 3.692 3.250 1.737 1.095 1.134 0.347 1.466 1.650 SUBTOTAL 0.000 0.515 3.603 5.849 5.009 9.290 2.331 0.155 0.000 26.753 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS E OF ELEVATED STABILITY CLASS E 2137.000 1948. 590 620.630 571.710 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED! 2004/09/13 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-79

I SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 1)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2004 - JUN 30, 2004 WIND DIRECTION WIND SPEED(HPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL 0.000

0. 000 0.000 0O000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 O. 000
0. 000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.094 0.000 0.047 0.000
0. 000 0.140 0.000 0.047 0.047 0.047 0.094 0.094 0.047 0.047 0.094 0.000 0.000 0.702 0.047 0.094 0.047 0.140 0.234
0. 094 0.047 0.140 0.140 0.094 0.374 0.140 0.047 0.094 0.000 0.000 1.731 0.090 0.139 0.137 0.044 0.045 0.047 0.000 0.088 0.044
0. 093 0.226 0.000 0.000 0.000 0.000 0.045 0.997 0.249 0.281 0.281 0.212 0.085 0.000 0.043 0.129 0.079 0.157 0.000 0.000 0.000 0.000 0.000 0.040 1.556 0.000 0.038 0.154 0.000 0.000 0.000 0.000 0.000 0.077 0.038 0.000 0.000 0.000 0.000 0.000 0.077 0.385 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0 000 0.000 0.000 0 000 0.000
0. 000 0.000
0. 000 0.000 0.386 0.646 0.619 0.397 0.504 0.140 0.136 0.451 0.387 0.475 0.693 0.187 0.094 0.187 0.000 0.162 5.466 HOURS OF VALID OBSERVATIONS HOURS OF BLEVATBD RELEASES HOURS OF STABILITY CLASS F HOURS OF ELEVATED STABILITY CLASS F 2137.000 1948.590 132.740 116.800 MErEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 MIS DATE PRINTED: 2004/09/13 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-80

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C (DELTA T > 4.0 C/100 M)

Browns Perry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2004 - JUN 30, 2004 WIND DIRECTION WIND SPEED(MPH)

CALM 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24. 5 TOTAL N

NE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 a.ooo 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.094 0.000 0.000 0.000 0.000 0.000 0.000 0.187 0.047 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.281 0.000 0.000 0.000 0.000 0.000 0.094 0.094

0. 000 0.047 0.047 0.187 0.000 0.000
0. 000
0. 000
0. 000 0.468 0.000 0.000 0.000 0.045 0.000 0.000 0.090 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.226 0.041 0.000 0.000 0.000 0.000 0.000 0.042 0.085 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.168 0.000 0.000 0.000 0.000 0.000 0.000 0O.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 O.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.088 0.000 0.000 0.045 0.000 0.094 0.413 0.222 0.047 0.140 0.187 0.000 0.000 0.000 0.000 0.000 1.236 TOTAL TOTAL TOTAL TOTAL HOURS OF VALID OBSERVATIONS HOURS OF ELEVATED RELEASES HOURS OF STABILITY CLASS G HOURS OF ELEVATED STABILITY CLASS G 2137.000 1948.590 33.460 26.410 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2004/09/13 NOTE.

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-81

METEOROLOGICAL DATA TABLES BROWNS FERRY NUCLEAR PLANT JANUARY - DECEMBER 2004 TABLE 20 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR SPLIT LEVEL RELEASES (ELEVATED PORTION)

THRD QUARTER E2-82

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T-<--1.9 C/100 M)

Browns Ferry Nuclear Plant PART 2 OiF 2 ELEVATED RELEASE MODE JUL 1,

2004 -

SEP 30, 2004 WIND DIRECTION WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNB NB ENE E

ESE SB SSB S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 O.000 0.000 0.000 0.000 0.000 0,000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000
0. 000
0. 000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000 0O.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0 000 0.000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0. 000 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS A OF ELEVATED STABILITY CLASS A 2185.000 2003.670 18.710 0.000 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 MIS DATE PRINTED:

2004/12/21 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-83

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2004 -

SEP 30. 2004 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW3 NNW SUBTOTAL TOTAL TOTAL TOTAL 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 O.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 O.000 0.000 0.000 0.000.

0.000 0.000 0.000 0.000 0.000 0.000 0,000 0,000 0.000 0.000 0.000 0.000 0.000 0.000 O.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 O.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 O.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 O.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 HOURS OF VALID OBSERVATIONS HOURS OF ELEVATED RELEASES HOURS OF STABILITY CLASS B 2185.000 2003.670 9.950 TOTAL HOURS OF ELEVATED STABILITY CLASS B 0.000 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2004/12/21 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-84

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2004 -

SEP 30, 2004 WIND DIRECITON N

NNE NE ENE E

ESE SE SSE S

SEW SW WSW W

WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.039 0.000 0.000 0.000
0. 000 0.158 0.038 0.000 0O.000 O.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.235 0.074 0.000 0.000 0.000 0.000 0.000 0.297 0.000 0.000 0.000 0.000 0.000 D.000 0.000 0.000 0.000 0.370 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0,000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.113 0.000 0.000 0.000 0.000 0.158 0.335 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.605 HOURS OF VALID OBSERVATIONS HOURS OF ELEVATED RELEASES HOURS OF STABILITY CLASS C HOURS OF ELEVATED STABILITY CLASS C 2185.000 2003.670 23.080 13.230 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2004/12/21 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-85

SPLIT JOINT PERCENTAGE FREQUENCIES OP WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

[-1.5< DELTA T<=-0.5 C/100 M)

Browns Ferry Nuclear Plant PART 2 OP 2 ELEVATED RELEASE MODE JUL 1,

2004 - SEP 30, 2004 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSw SW WSW W

WNW Nn NNW WIND SPEED(MPH) 3.5-5.4 5.5-7.4 CALM 0.6-1.4 1.5-3.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL 0.000 0.000 0.000 0,000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.137 0.046 0.229-0.046 0.092 0.137 0.595 0.915 0,824 1.053 0.824 0.778 0.229 0.137 0.092 0.137 0.686 0.503 0.412 0.183 0.229 0.503 1.098 0.686 0.915 1.327 1.144 1.465 1.602 0.458 0.503 0.275 1.357 0.755 0.264 0.220 0.258 0.303 0.919 0.664 0.883 0.709 0.446 0.583 1.017 0.969 1.195 1.058 1.910 1.770 0.363 0.168 0.241 0.839 1.686 0.960 1.245 0.641 0.245 0.163 1.070 0.570 1.176 0.965 0.641 0.784 0.187 0.000 0.000 0.448 1.827 0.489 0.340 0.150

0. 000 0.075 0.037 0.150 0.368 0.848 0.200 0.127 0.000 0.000 0.000 0.000 0.081 0.035 0.000 0.000 0.000 0.000 0.000 0.000 0.108 0.093 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.015 0.006 4.932 3.985 1.455 0.617 0.820 2.231 6.206 3.796 4.208 3.880 2.659 3.064 3.954 2.284 3.456 3.381 SUBTOTAL 0.000 0.046 6.270 11.991 11.600 14.013 6.343 0.644 0.021 50.928 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS D OF ELEVATED STABILITY CLASS D 2185.000 2003. 670 1172.570 1112.780 METEOROLOGICAL FACILrTY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 MIS DATE PRINTED: 2004/12/21 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-86

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE JUL 1,

2004 -

SEP 30, 2004 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4

>=24. 5 TOTAL 0.000 0.046 0.000 0.000 0.000 0.000 0,000 0.000 0.000 0.092 0.046 0.046 0.092 0.000 0.000 0.000 0.183 0.412 0.092 0.275 0.320 0.183 0.092 0.320 0.412 0.458 0.778 0.595 0.320 0.183 0.046 0.366 0.320 0.412 0.229 0.183 0.183 0.229 0.183 0.229 0.366

0. 4S8 0.503 0.366 0.641 0.275 0.183 0.320 0.796 0.522 0.264 0.395 0.395 0.438 0.356 0.268 0.136 0.224 0.088 0.089 0.486 0.130 0.175 0.484 1.973 1.886 0.595 0.403 0.654 1.993 0.770 0.324 0 488 0.281 0.000 0.038 0.202 0.080 0.558 0.882 0.374 0.672 0.225 0.076 0.000 0.189 0.038 0.038 0.000 O.000 0,000 0.000 0.038
0. 038 0.000 0.076 0.000 0.000 0.055 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000 3.647 3.950 1.459 1.331 1. 553 3.032 1.438 1.179 1.402 1.512 1.415 1.134 1.778 0.705
0. 962 2.129 SUBTOTAL 0.000 0.320 5.034 5.080 5.246 11.130 1.762 0.055 0,000 28.628 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASE$

OP STABILITY CLASS E OP ELEVATED STABILITY CLASS E 2185.000 2003.670 669.340 625.530 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 MIS DATE PRINTED: 2004/12/21 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-87

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T4= 4.0 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2004 - SEP 30, 2004 WIND DIRECTION CALM WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE BNE B

ESE SE SSE S

SW SW WSW W

WNW NW NNW SUBTOTAL

0. 000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.000 0.000 0.000 0.000 0.092 0.046 0.046 0.092 0.046 0.046 0.000 0.000 0.046 0.046 0.137 0.046 0.046 0.046 0.000 0.000 0.000 0.641 0.183 0.275 0.092 0.000 0.137
0. 000
0. 000 0.000 0.000 0.183
0. 092 0.000
0. 000 0.000 0.000
0. 000
0. 961 0.267 0.179 0.530 0.216 0.304 0.086 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.043 1.671 1.394 1.222 0.359 0.369 0.891 1.202 0.043 0.000 0.000 0.120 0.000
0. 000 0.000 0.000 0.041 0.205 5.844 0.114 0.228 0.038 0.038 0.038 0.000 0.000 0.000 0.000 0. 000 0.000 0.000 0.000 0. 000 0.000 0.000 0.456 0.000 0.0oo 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0o000 0.000 0.000 0.000 0.000 0.000 0.000 0.o000

-0. 000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0,000 0.000
0. 000 0o000 0.000 0.000 0.000 0.000 0o000 2.003 1.949 1.109 0.669 1.416 1.289 0.088 0.046 0.046 0.440 0.183 0.092 0.046 0.000 0.041 0.248 9.665 TOTAL HOURS TOTAL HOURS TOTAL HOURS TOTAL HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS F OF ELEVATED STABILITY CLASS F
  • 2185.000 2003.670 241.310 211.180 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWERN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:

TOTALS AND SUBTOTALS ARE OBTAINRD FROM UNROUNDED NUMBERS DATE PRINTED: 2004/12/21 E2-88

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2004 -

SEP 30, 2004 WIND DIRECTION CALM WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000

0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0. 000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.092 0.000 0.046
0. 000
0. 000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000.

0.000 0.000 0.137 0.043 0.000 0.045 0.000 0.044 0.000 0.000 0.000 0.000 0 000

0. 000 0.000 0.000 0.000 0.000 0.000 0.133 0.397 0.237 0.081 0.238 0.039 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.992 0.000 0.567 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.567 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.532 0.803 0.172 0.284 0.083 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.874 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS G OF ELEVATED STABILITY CLASS G 2185.000 2003.670 50.04 0 40.950 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BET'WEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 HIS DATE PRINTED: 2004/12/21 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-89

METEOROLOGICAL DATA TABLES BROWNS FERRY NUCLEAR PLANT JANUARY - DECEMBER 2004 TABLE 21 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR SPLIT LEVEL RELEASES (ELEVATED PORTION)

FOURTH QUARTER E2-90

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASR MODE oCT 1, 2004 -

DEC 31, 2004 WIND DIRECTION WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.S TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW Wsw Wwrn NW NNW SUBTOTAL O.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 O.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0. 000 0.000 o.ooo 0.000 o.ooo 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 O.000 0.000 D.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.045 0.000 0.000 0.000 0.000 0. 000 0.000 0.000 0.000 0.000 0.045 0.000 0.000 0.000
0. OD0 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.022 D.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.022 0.000 0.000 0.000 0000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 O.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.067 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 067 TOTAL HOURS OF VALID OBSERVATIONS TOTAL TOTAL TOTAL HOURS HOURS HOURS OF ELEVATED RELEASES OF STABILITY CLASS A OF ELEVATED STABILITY CLASS A 2135.000 1873.840 13.470 1.440 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 MIS DATE PRINTED: 2005/02/11 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-91

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE OCT 1, 2004 -

DEC 31, 2004 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0,000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0000
0. 000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0, 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000
0. 000
0. 000 0.000 0,000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL HOURS TOTAL HOURS TOTAL HOURS TOTAL HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS B OF ELEVATED STABILITY CLASS B 2135.000 1873.840 8.130 0.000 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2005/02/11 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-92

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 N)

Browns Ferry Nuclear Plant PART 2 OF 2 BLEVATED RELEASE MODE OCT 1,

2004 -

DEC 31. 2004 WIND DIRECTION CALM 0.6-1.4 WIND SPEED(MPH) 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE HEB ESE SE SSE S

SSW SW WSW W

WNW NW U NW SU8TOTAL TOTAL TOTAL TOTAL TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 a.0oD 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

.0,000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000

0. 000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 O. 000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 O.000 0.000 O.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.039 0.000 0.000
0. 000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.039 0.000 0.000 0.000 O.0D00 0.000 0.038 0.000 0.000 0.000 0.000 O.000 0.000 0.038 0.000 0.000 0.000 0.077 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.059 0.000 0.000 0.000 0.059 0.DO0
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.078 0.000 0.000 0.000 0.047 0.000 0.000 0.097 0.000 0.000 0.000 0.222 HOURS OF VALID OBSERVATIONS HOURS OF ELEVATED RELEASES HOURS OF STABILITY CLASS C HOURS OF ELEVATED STABILITY CLASS C 2135.000 1873.840 12.560 4.740 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2005/02/11 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-93

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE OCT 1, 2004 -

DEC 31, 2004 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24. S TOTAL N

NE NE ENE E

ESE SE SSEW S

SSW sW WSW W

WNW NW NNW 0.000 0.000 0.000 0.000 0.000

0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.047 0.000 0.234 0.187 0.094 0.187 0.281 0.234 0.328 0.281 0.234 0.468 0.656 0.468 0.375 0.187 0.094 0.234 0.141
0. 515 0.094 0.281 0.468 0.328 0.609 0.281 0.281
0. 515 0.937 0.703 0.328 0.234 0.562 0.187 0.540 0.641 0.186 0.457 0.363 0.316 0.496 0.412 0.405 0.360 0.270 0.540 0.502 0.763 0.538 0.230 1.244 0.771 0.286 0.000 0.170 1.187 1.051 0.817 1.096 0.738 0.610 0.824 1.550 0.702 1.513 0.904 0.910 0.686 0.039 0.000 0.000 0.349 1.560 2.312 1.370 0.842 0.306 0.154 1.032 0.530 1.780 0.455 0.037 0.000 0.000 0.000 0.000 0.030 0.544 0.560 0,756 0.069 0.000 0.000 0.106 0.467 0.493 0.178 0.000 0.000
0. 000 0.000 D. 000
0. 000 0.035
0. 009 0.030 0.000 0.000
0. 000
0. 000 0.013
0. 011 0.000 3.152 2.801 0.698 0.925 1.282 2.490 4.622 4.673 4.172 2.992 2.778 2.736 3.893 2.898 5.038 2.190 SUBTOTAL 0.000 0.187 4.543
6. 464 7.019 13.464 12.324 3.241 0.098 47.340 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS D OF ELEVATED STABILITY CLASS D 2135.000 1873.840 1121.500 1010.710 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2005/02/11 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-94

SPLIT JOINT PBCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5.C/100 M)

Browns Perry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE OCT 1, 2004 -

DEC 31, 2004 WIND DIRECTION WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE B

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0.000

0. 000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.094 0.000 0.094 0.000 0.047 0.000 0.000 0.047 0.094 0.000 0.000 8.000 0.047 0.000 0.000 0.047 0.000 0.047 0.094 0.234 0.141 0.234 0.375 0.315 0.281 0.234 0.468 0.094 0.094 0.141 0.187 0.187 0.187 0.094 0.328 0.187 0.609 0.328 0.562 0.515 0.422 0.515 0.562 0.234 0.468 0.141 0.234 0.047 0.045 0.227 0.315 0.453 0.719 0.721 0.861 0.729 0.543 0.407 0.273 0.227 0.316 0.178 0.093 0.045 0.828 0.859 0.702 O.456 0.787 2.116 1.756 1.322
1. 192
0. 572 0.248 0.168 0.461 0.294 0.403 0.447 0.116 0.307 0.114 0.039 0.,000 0.464 0.915
0. 844 0.188 0.385 0.039 0.000 0.000 0.000 0.078 0.193 0.000 0.000 0.000 0.000 0.000 0.000 0.254 0.314 0.244 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.007 0.016 0.015 0.000 0.000 0.000 0.011 0.000
0. 000 0.000 1.270 1.533 1.646 1.370 2.303 3.863 4.729 4.163 2.977 2.114 1.590 0.722 1.397 0,753
0. 995 0.966 SUBTOTAL.

0.000 0.468 3.185 5.433 6.152 12.609 3.680 0.812 0.049 32.389 TOTAL HOURS OF VALID OBSERVATIONS TOTAL HOURS OF ELEVATED RELEASES TOTAL HOURS OF STABILITY CLASS E TOTAL HOURS OF ELEVATED STABILITY CLASS E 2135.000 1873.840 774.340 691.500 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2005/02/11 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2 -95

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODS OCT

1. 2004 -

DEC 31, 2004 WIND DIRECTI ON

0. 6-1.4 WIND SPEED(MPH) 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NE NS ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0O.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.094 0.094 0.187 0.141 0.094 0.047
0. 000 0.141 0.094 0.047
0. 000 0.000 0.984 0.000 0.000 0.047 0.187 0.000 0.328 0.328 0.094 0.375 0.047 0.281 0.187 0.141 0.047 O. 000 0.000 2.061 0.045 D.000 0.046 0.134 0.134 0.357 0.364 0.093 0.093 0.044 0.228 0,000 0.094 0.000 0.000 0.000 1.633 0.000 0.040 0.083 0.201 0.247 0.446 0.369 0.000 0.042
0. 084 0.000 0.000 0.000 0.000 0.000 0.125 1.637 0.000 0.076 0.000 0.039 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.115 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.045 0.163 0.176 0.562 0.475 1.225 1.248 0.327 0.604 0.222
0. 509 0.328 0.328 0.094 0.000 0.125 6.430 SUBTOTAL 0.000 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS F OF ELEVATED STABILITY CLASS F 2135.000 1873.840 166.600 137.280 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWhEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2005/02/11 NOTE TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2 -96

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

Browns Perry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE OCT 1, 2004 -

DEC 31, 2004 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NKW SUBTOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 O.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.094 0.000

0. 000
0. 000 0.000
0. 000
0. 000 0.187 0.094
0. 000
0. 000 0.000
0. 000
0. 000
0. 000.
0. 000 0.047 0.328 0.000 0.047 0.000 0.000 0.000 0.088 0.137 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.318 TOTAL 0.085 0.040 0.166
0. 040
0. 000 0.083 0.127 0.000 0.000
0. 000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.541 0.000 0.000 0.039
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.039 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.085 0.087 0.205 0.040 0.000 0.171 0.451 0.141 0.046 0.000 0.000 0.000 0.000
0. 000 0.000 0.094 1.319 TOTAL HOURS TOTAL HOURS TOTAL HOURS TOTAL HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS C OF ELEVATED STABILITY CLASS G 2135.000 1873.840 38.400 28.170 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BEWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 MIS DATE PRINTED: 2005/02/11

NOTE, TOTALS AND SUBTOTALS ARE OBTAINED PROM UNROUNDED NUMBERS E2 -97

METEOROLOGICAL DATA TABLES BROWNS FERRY NUCLEAR PLANT JANUARY - DECEMBER 2004 TABLE 22 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR ELEVATED RELEASES FIRST QUARTER E2-98

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

Browns Ferry Nuclear Plant JAN 1,

2004 -

MAR 31, 2004 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM

>=24. 5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0,000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0,000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 D.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL HOURS TOTAL HOURS TOTAL HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A 2182 0

0 2173 0

TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS TOTAL HOURS CALM METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2004/05/13 MEAN WIND SPEED =

0.00 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-99 OEM

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

Browns Ferry Nuclear Plant JAN 1,

2004 -

MAR 31, 2004 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 6ALM

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SsW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000
0. 000 0.000 0.000

,0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000
0. 000 0.000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000 0.000
0. 000
0. 000
0. 000 0.000
0. 000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 TOTAL HOURS OF VALID STABILITY TOTAL HOURS OF STABILITY CLASS OBSERVATIONS B

TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABIBITY OBSERVATIONS CALM 2182 1

2173 0

METEOROLOGICAL FACILXTY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.S9 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED; 2004/05/13 MEAN WIND SPEED =

7.60 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-100

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

Browns Perry Nuclear Plant JAN 1,

2004 -

MAR 31, 2004 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000.

0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000
0. 000
0. 000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000 0.000
0. 000 0.046 0.000
0. 000 0.000
0. 000 0.046 0.000 0.000 0.000 0.000 0.092 0.000 0.000 0.000 0.000 0.000 0O.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000 0.000
0. 000
0. 0oo
0. 000 0.000 0.o000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046
0. 000 0.000 0.000 0.046 0.046 0.000 0.000 0.000 0.000 0.138 TOTAL HOURS TOTAL HOURS TOTAL HOURS TOTAL HOURS TOTAL HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C OF VALID WIND DrRECTION-WIND SPBED-STABILITY OBSERVATIONS CALM 2182 3

3 2173 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2004/05/13 MEAN WIND SPEED =

8.40 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-101

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

Browns Ferry Nuclear Plant JAN 1,

2004 -

MAR 31, 2004 WIND DIRECTION N

NNE NE ENEE E

ESE SE SSE S

sSW SW WSW W

WNW NW NNW WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.046 0.046 0.138 0.092 0.046 0.184 0.046 0.322 0.322 0.092 0.230 0.322 0.138 0.092 0.092 0.000 0.000 0.184 0.184 0.322 0.276 0.184 0.506 0.276 0.506 0.368 0.230 0.184 0.506 0.184 0.276 0.230 0.414 0.322 0.230 0.092
0. 506 0.736 0.414 0.046 0.230 0.230 0.092 0.138 0.460 0.322 0.322 0.276 2.117 2.439 1.197 0.736 0.322 0.552 0.506 0.782 0.736 0.690 0.460
0. 414 1.289 1.887 1.335 1.427 2.439 1.657 0.874 0.460 0.046 0.506 0.506 1.012 2.209 1.150 0.230 0.184 0.874 2 071 2.301 2.209 0.828 0.092 0.414 0.000 0.138 0.368 0.230 0.322 1.058
0. 552 0.230 0 184 0.506 1.519 1.197 0.690 0.276 0.092 0.04 6 0.000 0.046 0.092 0.414 0.046 0.460 0.276
0. 000 0.000 0.046 0.230 0.230 0.092 6.121 4.832 3.083 1.749 1.381 2.669 2.623 2.807 5.522 3.359 1.473 1.427 3.820 6.351 5.752 4.924 SUBTOTAL 0.000 0.138 2.209 4.418 4.832 16.889 18.730 8.329 2.347 57.892 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS D TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STAB+/-LITY OBSERVATIONS TOTAL HOURS CALM 2182 1260 1258 2173 0

METEOROLOGICAL FACILITY:

Browns Perry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED = 13.04 DATE PRINTED; 2004/05/13 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-102

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

Browns Ferry Nuclear Plant JAN 1, 2004 - MAR 31, 2004 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.6-1.4

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0O.000 0.000 0.000 0.000 0.000 0.046 0.046 0.000 0.046 0.046 0.046 0.046 0.092 0.092 0.092 0.230 O.000 0.046 0.04 6 0.874 0.092 0.23 0 0.092 0.092 0.138 0.276 0.184 0.184 0.322 0.092 0.092 0.276 0. 000 0.092 0.092

0. 000 2.255 0.230 0.322 0.046 0.092 0.322 0.046 0.368 0.506 0.322 0.184 0.184 0.138 0.138 0.184 0.092 0.046 0.736 0.966 0.598 0.460 0.552 0.598 1.243 1.289 1.243 0.552 1.058 0.874 0.828
1. 012 0.276 0.322 0.920 0.920 0.828 0.552 0.230 0.644 1.427 1.933 2.025 0.690 0.230 0.138 0.368 0.276 0.184 0.368 0.000 0.092 0.138 0.000 0.000 0.4 60 0.368 1.012 0.598 0.046 0.138 0.046 0.092 0.046 0.276 0.092 3.405 0.046
0. 000 0.000 0.000
0. 000 0.092 0.368 0.414 0.506 0.046 0.000 0.000 0.046 0.000
0. 046 0.000 2 025 2.531 1.749 1.243 1.243 2.163 4.004 5.384 5.062 1.703 1.795 1.565 1.703 1.611 1.012 0.874 3.221 12.609 11.735 1.565 35.665 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS E TOTAL HOURS TOTAL HOURS TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2182 782 775 2173 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2004/05/13 MEAN WIND SPEED = 12.63 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-103

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F 1 1.5< DELTA T<= 4.0 C/100 M)

Browns Ferry Nuclear Plant JAN 1,

2004 -

MAR 31, 2004 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL CALM 0.000

0. 000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.6-1.4 WIND SPEED(MPH) 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.138 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.184
0. 000
0. 000 0.000
0. 000 0.092
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000 0.046
0. 000
0. 000
0. 000 0.138 0.000 0.000 0000 0.046 0.046 0.092 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.230 0.092 0.046 0.046 0.276 0.230 0.368 0.138 0.184 0.322 0.184 0.368 0.138 0.184
0. 000 0.092
0. 000 2.669

>=24.S TOTAL 0.184 0.138 0.046 0.046 0.092 0.184 0.230 0.276 0.184 0.184 0.092 0.000

0. 184 0,000 0.000 0.092 1.933 0.000 0.000 0.000 0.000 0.138 0.000 0.092 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.230 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.276 0.184 0.092 0.368 0.598 0.644 0.598 0.506 0.552 0.368 0.460 0.138 0.414 0.000 0.092 0.092 5.384 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS F TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F 2182 117 117 2173 0

TOTAL HOURS OP VALID WIND DIRECTION-WIND SPEED-STABILITY TOTAL HOURS CALM OBSERVATIONS METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2004/05/13 MEAN WIND SPEED = 11.61 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINBD FROM UNROUNDED NUMBERS E2-104

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/lao M)

Browns Ferry Nuclear Plant JAN 1, 2004 -

MAR 31, 2004 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW BTW SUBTOTAL 0.000 0.000 0.000 0.000

0. 000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 O.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0,000 0.000 0.000
0. 000 0.000 0.000 0.046 0.276 0.092 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.460 0.000 0.000 0.000 0.138 0.138 0.000 0.046 0.046 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.414 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.138 0.138 0.000 0.092 0.322 0.092 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.874 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS G TOTAL HOURS TOTAL HOURS TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OF VALID WIND DrRECTION-WIND SPEED-STABILITY CALM CLASS G OBSERVATIONS 2182 19 19 2173 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED; 2004/05/13 MEAN WIND SPEED = 12.15 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-105

IMPACT ASSESSMENT BROWNS FERRY NUCLEAR PLANT JANUARY - DECEMBER 2004 TABLE 23 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR ELEVATED RELEASES SECOND QUARTER E2-106

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/l1O M)

Browns Ferry Nuclear Plant APR 1, 2004 - JUN 30, 2004 WIND DIRECTION WIND SPEED (MPH) 0,6-1.4 1.5-3,4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM

18. 5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0. 000 0.000 0. 000 0.000 0. 000 0. 000 0. 000 0. 000

0. 000
0. 000
0. 000
0. 000 0.000
0. 000
0. 000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000.

0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0, 000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.0o00 0.000 0.000 0.000 0.000 0.000 0.000
0. 0oo 0.000
0. 000 0.000 0.000 0.000 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS A TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS TOTAL HOURS CALM METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL 2143 0

0 21.40 0

DATE PRINTED: 2004/09/13 MEAN WIND SPEED =

0.00 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2 -107

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

Browns Ferry Nuclear Plant APR 1, 2004 -

JUN 30, 2004 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL CALM 0.000 0.000 0.000 0.000 0.o00 0.000 0.000 0.000

0. 000 0.000 0.000 0.000

.o000 0.000 0.000 0.000 0.000 WIND SPEED(NPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 O.000 0.000 0.000 0.000 0.000 0.000

0. 000
0. 000
0. 000 O.000 0.000
0. 000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0,000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 TOTAL TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS HOURS OF VALID STABILITY OF STABILITY CLASS OBSERVATIONS B

OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2143 0

0 2140 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2004/09/13 MEAN WIND SPEED =

0.00 NOTEB TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-108

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/10D M)

Browns Perry Nuclear Plant APR 1, 2004 - JUN 30, 2004 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3,5-5.4 5.5-7.4 CALM:

0. DOO 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL 0.000 0.000 0.000 O.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000
0. 000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.140 0.000
0. 000 0.000 0.000 0,000
0. 000 0.000 0.000 0,000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.047 0.047 0.000 0.000 0.093 0.000
0. 000 0.000
0.

000 0, 000 0.234 TOTAL HOURS OF VALID STABILITY TOTAL HOURS OF STABILITY CLASS OBSERVATIONS C

TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C 2143 5

5 2140 0

TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY TOTAL HOURS CALM OBSERVATIONS METEOROLOGICAI FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DRLTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2004/09/13 MEAN WIND SPEED = 10.28 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUM4BERS E2-109

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

Browns Ferry Nuclear Plant APR 1, 2004 - JUN 30, 2004 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALE

-24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNO SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0,047 0.000 0.000 0.047 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.140 0.047 0.047 0.047 0.000 0.000 0.093 0.654 0.607 0.514 0.701 0.701 0.187 0.187 0.093 0.000 0.000 3.879 0.140 0.280 0.047 0.093 0.140 0.561 0.888 0.748 0.701 0.607

0. 607 0.654 0.701 0.327 0.187
0. 000 6.682 0.421 0.280 0.000 0.000 0.093 0.140 0.701 0.748 0.794 1.075 1.121 0.374 1.402 0.514 0.561 0.234 1.028 1.402 0.421 0.140 0.047 0.514 2.103 2.243 2.897 2.336 2.991 1.682 1.402 1.636 1.075 0.981 0.794 0.514 0.561 0.000 0.000 0.234 1.075 2.710 2.336 2.383 1.495 0.374 0.327 0.981 1.168 1.449 0.140 0.140 0.047 0.000 0.000 0.000 0.187 0,748 1.215 1.495 0.093 0.000 0.000 0.093
0. 981 0.093 5.234 0.000 0O.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.093 0.047 0.000
0. 000 0.000
0. 093 0.000 2.617 2.664 1.121 0.280 0.280 1.542 5.607 7.897 8.458 8.692 7.056 3.271 4.019 3.645 4.065 2.757 8.458 22.897 16.402 0.280 63.972 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS D TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2143 1369 1369 2140 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2004/09113 MEAN WIND SPEED = 10.70 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-110

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-O.54 DELTA T<= 1.5 C/100 M)

Browns Ferry Nuclear Plant APR 1, 2004 - JUN 30, 2004 WIND DIRECTION WIND SPEED (MPH)

CALM 0.6-1.4 1.5-3.4 3.5-S.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NB ENE E

ESE SB SSE S

SSW SW WSW W

WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.093 0.000 0.093 0.000 0.093 0.093 0.000 0.000 0.000 0.187 0.093 0.000 0.047

0. 047 0.234 0.280 0.140 0.280 0.187 0.093 0.047 0.234 0.047 0.000 0.093 0,093 0.047 0.000 0.140 0.280 0.327 0.234 0.187 0.374 0.187 0.280 0.374 0.140 0.140 0.093 0.093 0.093 0.093 0.047 0.140 0.421 0.327 0.421 0.327 0.607 0.467 0.280 0.234 0.187 0.093 0.047 1.121 0.374 0.514 0.327 0.421 0.561 1.075 0.981 0.654 1.402 0.935 0.607 0.421 0.234 0.234 0.234 0.701 0.607 0.234 0.093 0.000 0.327 0.748 0.467 1.168 1.308 0.280 0.047 0.093 0.140 0.888 0.748 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.140 0.421 0.467 0.000 0.000 0.000 0.000 0.327 0.140 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2.103 1.355
0. 9 81
0. 467 0.748 1.682 2.710 2.523 2.991 4.439 2.150 1.308 1.262 1.028 1.729 1.262 SUBTOTAL 0.000 0.421 1.916 2.991 3.879 10.093 7.850 1.589 0.000 28.738 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OP STABILITY CLASS E TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS S OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2143 618 615 2140 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED:

2004/09/13 MEAN WIND SPEED = 10.23 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-111

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

Browns Ferry Nuclear Plant APR 1,

2004 -

JUN 30, 2004 WIND DIRECTION WIND SPEED(MPH)

CALM 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL

0. 000
0. 000 0.000 0.000
0. 000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.047 0.047 0.000 0.000 0,000 0.000 0.000 0.140 0.047 0.047 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.047 0.234 0.000 0.000 0.047
0. 000 0.000 0.000 0.093 0.047 0.000 0.047 0.234 0.093 0.000 0.047 0.140 0.000 0.748 0.000 0.093 0.000 0.093 0.000 0.093 0.000 0.000 0.047 0.000 0.140 0.047 0.000 0.000 0.140 0.000 0.654 0.000 0.234 0.234 0.140 0.234 0.047 0.047 0.093 0.140 0.093 0.374 0.374 0.000 0.000 0.000 0.000 2.009 0.187 0.327 0.140 0.093 0.047 0.000 0.000 0.047 0.000 0.234 0.000 0.000 0.000 0.000 0.000 0.093 1.168 0.000 0.093 0.234 0.140 0.000 0.000 0.000 0.000 0.047 0.234 0.000 0.000
0. 000 0.000
0. 000 0.093 0.841 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.234 0.794 0.654 0.467 0.280 0.140 0.187 0.187 0.280 0.654 0.794 0.561 0.000 0.047 0.280 0.234 5.794 TOTAL HOURS OF VALID STABILITY TOTAL HOURS OF STABILITY CLASS OBSERVATIONS F

TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS TOTAL HOURS CALM METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL 2143 124 124 2140 0

DATE PRINTED: 2004/09/13 MEAN WIND SPEED = 10.98 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-112

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/lOO M)

Browns Ferry Nuclear Plant APR 1, 2004 -

JUN 30, 2004 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5 CALM

-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESB SE SSE S

SSW SW WSW W

WNW NW NNW SVBTOTAL 0.000 0.000 0,000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 D. 000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.047 0.093 0.093 0.000

0. 000 0.000
0. 000 0.000 0.000
0. 000
0. 000 0.234 0.000 0.000 0.000 0.000 0.000 0.047
0. 000 0.047 0.000 0.093 0.047
0. 000
0. 000 0.000 0.000 0.000 0.234 0.000 0.000 0.000 0.000 0.000 0.000 0.140 0.000 0.047 0.000 0.000 0.000 0.000 0,000 0.000 0.000 0.187
0. 000 0.000 0.000 0.047 0.000 0.000 0.000 0.047 0.140
0. 047 0.187
0. 000 0. 000
0. 000
0. 000 0.000
0. 467
0. 000 0.047 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.093 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0, 000
0. 000 0,000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000 0.000 0.047 0.000 0.047 0.000 0.093 0.234 0.280 0.187 0.140 0.234 0.000 0.000 0.000 J.000 0.000 1.262 TOTAL HOURS OF VALID STABILITY OE TOTAL HOURS OF STABILITY CLASS 0 BSERVATIONS TOTAL TOTAL TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS HOURS CALM 2143 27 27 2140 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2004/09/13 MEAN WIND SPEED =

7.23 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-113

METEOROLOGICAL DATA TABLES BROWNS FERRY NUCLEAR PLANT JANUARY - DECEMBER 2004 TABLE 24 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR ELEVATED RELEASES THIRD QUARTER E2-1 14

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

Browns Ferry Nuclear Plant JUL 1, 2004 -

SEP 30, 2004 WIND WIND SPEED(MPH)

DIRECTION CALM 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NNE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E

0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SSE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 S

0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SW 0.000 0.000 0,000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 W

0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2198 TOTAL HOURS OF STABILITY CLASS A 0

TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A 0

TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2196 TOTAL HOURS CALM 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2004/12/21 MEAN WIND SPEED =

0.00 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-115

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

/-1.9< DELTA T<=-1.7 C/lO M)

Browns Ferry Nuclear Plant JUL 1,

2004 - SEP 30, 2004 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE Sss SSW SW WSW W

WNW NW NNW SUBTOTAL WIND SPEED(MPR) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 0.000 0.000 0.000 0.000 O.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000
0. 000 0.000
0. 000 0.000 0.. 000 O.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 O.000
0. 000 0.000
0. 000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 O.000 0.000 O.000 0.000 0.000 0.000 0.000 0.000 0.000 O.000 0.000 0.000 0.000 0.000 0O.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000
0. 000 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS B TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B 2198 0

0 2196 0

TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY TOTAL HOURS CALM OBSERVATIONS METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2004/12/21 MEAN WIND SPEED =

0.00 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-116

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-l.5 C/100 M)

Browns Ferry Nuclear Plant JUL 1, 2004 -

SEP 30, 2004 WIND DIRECTION CALM WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 O. 000 0.000 D. 000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 O.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046
0. 000 0.000
0. 000
0. 000
0. 000 0.000
0. 000
0. 000
0. 000
0. 000 0.046 0.137 0.000 0.000 0.000 0.000 0.319 0.137 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.592 0.000 0.000 0.000 0.000 0.000 0.000 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.137 0.000 0.000 0.000 0.000 0.364 0.228 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.729 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS C TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS TOTAL HOURS CALM METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL 2198 16 16 2196 0

DATE PRINTED: 2004/12/21 MEAN WIND SPEED = 15.66 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-117

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D 1-1.5< DELTA T<=-0.5 C/100 M)

Browns Ferry Nuclear Plant JUL 1, 2004 - SEP 30, 2004 WIND DIRECTION WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNS W SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.00 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.137 0.046 0.182 0.137 0.182 0.091 0.319 0.319 0.592 0.638 0.546 0.911 0.729 0.364 0.137
0. 000 0.137 5.328 0.546 0.364 0.228 0.046 0.182 0.592 0.774 0.638 0,638 0.683 0,865 0.956 1.184 0.683 0.36g 0.182 8.925 0.774 0.729 0.364 0.182 0.091.

0,410 0.592 0.592 0.638 0.592 0.638 0.683 0.956 0.911 0.865 0.683 2.004 1.685 0.455 0.273 0.319 1.184 1.366 0.956 1.457

0. 820 0.956
0. 592 1.730 1.184 1.047 1.321 1.639 1.184 0.091 0.000 0.273 1.321 1.639 1.002 0.86S 0.364 0.091 0.091 0.137 0.182 0.638 0.820 0.546 0.137 0.091 0.000 0.000 0.319 0.683 0.046 0.000 0.046 0.000 0.091 0.046 0.000 0.319 0.729 3.051 0.137 0.046 0.000 0.000 0.000
0. 000 0.046 0.000 0.000 0.000 0.000 0.000 0. 000 0.000 0.273 0,046 5.692 4.326 1.366 0.683 0.956 4.144 5.419 3.825 4.281 3.097 3. 506 3.142 4.417 3.097 3.506 3.916 9.699 17.350 10.337 0.546 55.373 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS D TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D 2198 1216 1216 2196 0

TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY TOTAL HOURS CALM OBSERVATIONS METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2004/12/21 MEAN WIND SPEED =

9.33 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-118

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA Tc= 1.5 C/100 M)

Browns Ferry Nuclear Plant JUL 1, 2004 -

SEP 30, 2004 WIND DIRECTION N

NE NE B4 ENE E

ESE Se SSE S

SSW SW WSW W

NW NNW WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CAL?!

0.000 0.000 C.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4

>-24,5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.046 0.000 0.000 0.000 0.000 0.046 0.000 0.091 0.137 0.046

0. 091 0.182 0.046
0. 091 0.273 0.273 0.137 0.273 0.046 0.182 0.228 0.137 0.091 0.046 0.319 0.137
0. 091 0.091 0.091 0.228 0.364 0.137 0.137 0.319 0.364 0.729 0.592 0.137 0.228 0.182 0.137 0.228 0.137 0.091 0.091 0.228 0.273 0.319 0.091 0.273 0.228 0.182 0.592 0.182 0.091 0.228 1.457 1.002 0.774 0.455 0.410 1.002 1.184 0.319 0.410 0.501 0.228 0.319 0.546 0.319 0.182 0.638 1.821
l. 821 0.956 0.182 0.091 1.867 0.592 0.228 0.182 0.319 0.137 0.091 0.137
0. 046 0.319 0.683 0.364 0.592 0.273 0.046 0.000 0.137 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.137 0.273 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046
0. 000 4.372 4.098
2. 413 1.047 0.729 3.552 2.732 1.275 1.002 1.685 1.002 1.503 2.095 0.865 0.956 1.867 SUBTOTAL 0.000 0.228 2.277 4.144 3.370 9.745 9.472 1.412 0.546 31.193 TOTAL, HOURS TOTAL HOURS TOTAL HOURS TOTAL HOURS TOTAL HOURS OFIVALID STABILITY OBSERVATIONS OF STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2198 686 68S 2196 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2004/12/21 MEAN WIND SPBED = 10.73 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2 -119

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

Browns Ferry Nuclear Plant JUL 1, 2004 - SEP 30, 2004 WIND DIRECTION WIND SPRED(MPH) 0.6-1,4 1.5-3.4 3.5-5.4 S.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.000
0. 000 0.046 0.000 0.046 0.000
0. 000
0. 046
0. 000 0.046 0.273 0.046 0.046 0.000 0.046 0.000 0.046 0.000 0.046 0.000 0.046 0.000 0.046 0.000
  • 0.000 0.000 0.000 0.319 0.000 0.091 0.091 0.091 0.182 0.046 0.000 0.046 0.000 0.046 0.046 0.000 0.000 0.046 0.000 0.000 0.683 0.137 0.546 0.091 0.228 0.638 0.546 0.592 0.000 0.000 0.046 0.182 0.000 0.000 0.000 0.046 0.000 3.051 0.956 1.321 0.319 0.091 0.546 1.138 0.228 0.000 0.000 0.091 0.000 0.000 0.000 0.000 0.046 0.182 4.918 0.319 0.729 0.182 0.046 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 1.321 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000 1.457 2.732 0.683 O. 501 1.412 1.821 0.820 0.091 0.046 0.273 0.273 0.046 0.000 0.091 0.091 0.228 0.000 10.565 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS F TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS TOTAL HOURS CALM 2198 233 232 2196 0;

METEOROLOGICAL FACILITY:

Browns Perry Nuclear Plant STABILITY BASED ON DELTA-T BErwEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2004/12/21 MEAN WIND SPEED = 13.12 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2 -120

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS 0 (DELTA T > 4.0 C/100 M)

Browns Ferry Nuclear Plant JUL 1,

2004 - SEP 30, 2004 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW STW SUBTOTAL CALM 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.6-1.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED(MPH) 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046

0. 000
0. 000
0. 000
0. 000 0.046 0.000 0.000 0.000 0.000 0.000 0. 000 0.000 0.000 0.000 0.000 0.000 0.04 6 0.046 0.000 0.000 0.091 0.046 0.046 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.228 0.000 0.137 0.000 0.000 0.046 0.046 0.000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000
0. 000
0. 000 0.228 0.091 0.364 0.000 0.000 0.182 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.683 0.000 0.820 0.091 0.000 0.000 0.000 O.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 911 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0O.000 0.000 0.000 0.000 0.137 1.321 0.091 0.091 0.319 0.182 0.000 0,000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2.140 TOTAL HOURS TOTAL HOURS TOTAL HOURS TOTAL HOURS TOTAL HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2198 47 47 2196 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2004/12/21 MEAN WIND SPEED = 15.83 NarE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-121

METEOROLOGICAL DATA TABLES BROWNS FERRY NUCLEAR PLANT JANUARY - DECEMBER 2004 TABLE 25 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR ELEVATED RELEASES FOURTH QUARTER E2-122

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C1100 M)

Browns Perry Nuclear Plant OCT 1, 2004 - DEC 31, 2004 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000
0. 000
0. 000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0,000 0.000 0, 000
0. 000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 O.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0,000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000
0. 000 0.000
0. 000
0. 000 0.000 0.047
0. 000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.094 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.094 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS A TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS TOTAL HOURS CALM 2177 2

2 2135 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2005/02111 MEAN WIND SPEED = 15.90 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-123

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 Ct100 M)

Browns Ferry Nuclear Plant OCT 1, 2004 -

DEC 31, 2004 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0,000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0,000 0.000 0.000 0,000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000.

0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS B TOTAL HOURS TOTAL HOURS TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2177 0

0 2135 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BRTWEBN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2005/02/11 MEAN WIND SPEED =

0.00 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-124

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

Browns Ferry Nuclear Plant OCT 1, 2004 -

DEC 31, 2004 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE ESE SE SSE S

SSW SW WsW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0,000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000 0.Q00
0. 000
0. 000 0.047
0. 000
0. 000
0. 000
0. 000
0. 047 0.000 0.000
0. 000
0. 000 0.000
0. 000
0. 000
0. 000
0. 000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0O.000 0.000
0. 000 0.000
0. 000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.094 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.094 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.094 0, 000 0,000 0 000 0,094 0.000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0 000
0. 047 0. 000
0. 000
0. 000 0.047 0.000 0.000 0.000 0.000 0.000 0.094 0.000 0.000 0.000 0.000 0.000 0.047 0.141 0.000 0.000 0.000 0.281 TOTAL TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C 2177 6

6 2135 0

OF VALID WIND DIRECTION-WIND SPEED-STABILITY CALM OBSERVATIONS METEOROLOGICAL FACILITY.

Browns Perry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED; 2005/02/1l.

MEAN WIND SPEED = 17.03 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-125

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

Browns Ferry Nuclear Plant OCT 1,

2004 -

DEC 31, 2004 WIND DIRECTION CALM WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.047 0.000 0.047 0.047 0.234 0.094 0.234

0. 094 0.187 0.094 0.281 0.187 0.187 0.234 0.375 0.234 0.515 0.187 0.187 0.094 0.047 0.281 0.141 0.187 0.281 0.515 0.328 0.141 0.141 0.328 0.562 0.703 0.187 0.234 0.422
0. 000 0.468 0.422 0.187 0.187 0.328 0.375 0.422 0.422 0.094 0.328 0.328 0.562 0.468 0,843 0.141 0.281 1.358 0.843 0.i22
0. 468 0.468 0.562 0.609 0.749 1.171 0.468 0.515 0.890 0.937 0.984 1.265 0.609 1.265 1.124 0.234 0.000 0.187 1.311 1.593 2.155 1.733 1.124 0.656 0.703
1. 920 0.562 1.686 0.890 0.375 0.141 0.000 0.000 0.000 0.141 1.452 1.780 1.593 0.375 0.234 0.094 0.796 1.030 1.499 0.656 0.000
0. 000 0.000 0.000
0. 000
0. 094 0.749 0.234 0.422 0.141 0.000 0.000 0. 000 0.328 0.281 0.000 3.747 2.904 1.218 0.937 1.452 3.091 5.433 5,667 5.340 2.998 2.717 3.185 4.871 4.169
5. 527
2. 576 SUBTOTAL 0.000 0.187 3.419 4.496 5.855 12.319 17.143 10.164 2.248 55.831 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS D TOTAL HOURS Or VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D 2177 1210 1192 2135 0

TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY TOTAL HOURS CALM OBSERVATIONS METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2005/02/11 MEAN WIND SPEED = 12.97 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-126

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-0.5< DELTA T<= 1.5 C/100 M)

Browns Ferry Nuclear Plant OCT 1, 2004 - DEC 31, 2004 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NNW SUBTOTAL WIND SPEED(MPH) 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.001 0.002 0.002 0.001 0.003 0.001 0.005 0.003 0.007 0.006 0.004 0.005 0.004 0.002 0,002 0.002 0.047 0.6-1.4 0.000 G.000 0.000 0.000 0.000 0.000 0.047 0.047 0.047 0.047 0.047 0.000 0.094 0.000 0.000 0.000 0.328 1.5-3.4

>=24.5 TOTAL 0.047 0.094 0.094 0.047 0.141 0.047 0.187 0.094 0.281 0.234 0,141 0.234 0.094

0. 094 0.094 0.094 2.014
0. 000 0.141 0.047 0.094 0.047 0.375 0.187 0.328 0.187 0.141 0.375 0.141 0.094 0.187 0.047 0.141 2.529 0.094 0.094 0.141 0.141 0.094 0.281 0.281 0.375 0.187 0.187 0.375 0.187 0.047 0.328 0.328 0.094 0.328 0.468 0.515 0.468 0.890 1.124 1.311 1.733 1.593 0.703 0.796
0. 422 0.328 0.468 0.234 0.187 0.468 0.984 0.703 0.375 0.703 1.358 2.108 1.546 1.218 0.796 0.468 0.187 0.281 0.234 0.187 0.703 0.047 0.281 0.141 0.000 0.000 0.281 0.937 0.703 0.375 0.234 0000 0.094 0.000 0.000 0.000 0.094 3.185 0.000 0.000 0.000 0.000 0.000 0.000 0 141 0.328 0.234
0. 000 0.000
0. 000 0 047
0. 000 0.000
0. 000 0.985 2.063 1.641 1.125 1.876 3.467 5.204 5.155 4.128 2.348 2.205 1.269 0.987 1.313 0.892 1.313 3.232 11.569 12.319 0.749 35.972 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS E TOTAL HOURS TOTAL HOURS TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2177 782 768 2135 1

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2005/02/11 MEAN WIND SPEED = 11.84 NOTE TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-127

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.,5 DELTA T<= 4.0 C/100 M)

Browns Ferry Nuclear Plant OCT 1,

2004 -

DEC 31, 2004 WIND DIRECTION WIND SPEED(MPH) 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.6-1.4 1.5-3.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 O.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.047 0.000 0.047 0.047 0.047 0.000 0.047 0.047 0.000 0.000 0.047 0.047 0.000 0.000 0.375
0. 000 0.000 0.000 0.047 0.094 0.141 0.234 0.094 0.141 0.047 0.047 0.000 0.047 0.094 0.000 0.047 1.030 0.047 0.000 0.047 0.047 0.094 0.094 0.187 0.187 0.281 0.000 0.047 0.000 0.000 0.000 0.047 0.000 1.077 0.000 0.000 0.000 0.094 0.141 0.234 0.422 0.562 0.234 0.047 0.281 0.047
0. 000 0.047 0.094 0.047 2.248 0.000 0.047 0.000 0.094 0.187 0.094 0.468 0.047 0.094 0.187 0.094 0.000 0.000 0.000 0.047 0.000 1.358 0.000 0.047 0.047 0.047 0.094 0.047 0.000 0.000 0.0oo 0.000 0.000 0.00o 0.000 0.000 0.000 0.000 0.281 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.094 0.141 0.328 0.656 0.656 1.358 0.937 0.796 0.328 0.468 0.047 0.094 0.187 0.187 0.094 6.417 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS F TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS TOTAL HOURS CALM METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL 2177 147 137 2135 0

DATE PRINTED: 2005/02/11 MEAN WIND SPEED =

9.40 NOTE.

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

  • 2-128

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 N)

Browns Ferry Nuclear Plant OCT 1,

2004 -

DEC 31, 2004 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL

0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000
0. 000
0. 000 0.047
0. 000 0.047 0.000
0. 000
0. 000
0. 000 0.000
0. 000 0.000 0.047 0.047 0.047 0.000
0. 000
0. 000
0. 000
0. 000.
0. 000 0.141 0.000 O.000 0.000 0.000 0.000 0.000 0.000 0,141 0.141 0.000 0.000
0. 000
0. 000
0. 000 0.047 0.000 0.328
0. 000 0.000 0.047 0.047 0.094 0.000 0.094 0.1817 0.047 0.000
0. 000 0.000
0. 000
0. 000
0. 000
0. 000 0.515 0.094 0.000 0.000 0.094 0.000 0.000 0.047 0.000 0.047 0.000 0.000 0.000 0.000 0.000.

0.000 0.000 0.281 0.000 0.047 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.094 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.094 0.047 0.047 0.187 0.094 0.000
0. 141 0.375 0.281 0.047 0.000 0.000 0.000 0.000
0. 094 0.000 1.405 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS G TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS TOTAL HOURS CAIiM METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED 10.08 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS 2177 30 30 2135 0

DATE PRINTED: 2005/02/11 E2-129

ENCLOSURE 3 TENNESSEE VALLEY AUTHORITY BROWNS FERRY NUCLEAR PLANT (BFN)

UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT 2004 E3 -1

EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT YEAR 2004 LRegplatory and BFN ODCM Limits A.

Fission and Activation Gases in Gaseous Effluent:

The release of fission and activation gases is regulated by the dose limits of 10 CFR 50 Appendix I and BFN Offsite Dose Calculation Manual (ODCM). The air dose to areas at and beyond the site boundary due to noble gases released in gaseous effluents per unit, shall be limited during any calendar quarter to

  • 5 millirad (mrad) for gamma radiation and < 10 rnrad for beta radiation; and during any calendar year to < 10 mrad for gamma radiation and < 20 mrad for beta radiation.

B.

Iodines and Particulates with Half-Lives Greater than Eight Days in Gaseous Effluents.

The release of iodines and particulates in gaseous effluent is regulated by the dose limits of 10 CFR 50 Appendix I and the BFN ODCM. The dose to a member of the public from radioiodines, radioactive materials in particulate form, and radionuclides other than noble gases with half-lives greater than eight days in gaseous effluent released per unit to areas at and beyond the site boundary shall be limited to any organ during any calendar quarter to < 7.5 millirem (mrem), and during any calendar year to < 15 mrem.

C.

Liquid Effluents The release of radioactive liquid effluents is regulated by the dose limits of 10 CFR 50 Appendix I and the BFN ODCM. The doses or dose commitment to a member of the public from radioactive materials in liquid effluents released from each unit to unrestricted areas shall be limited during any calendar quarter to < 1.5 mrem to the total body and <5 mrem to any organ and during any calendar year to < 3 mrem to the total body and

  • 10 mrem to any organ.

II.

Limitation on Dose Rate A.

Fission and Activation Gases in Gaseous Effluent:

1. The instantaneous release rate of fission and activation gases is based on the dose rate limits of 10 CFR 20.1301 and the BFN ODCM. The dose rate at any time to areas at and beyond the site boundary due to noble gases released in gaseous effluents from the site shall be limited to
  • 500 mrem per year to the total body and < 3000 mrem per year to the skdn.
2. Tho BFN ODCM Section 7.2 determines the maximum noble gas release rate.

E3 -2

. r EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT YEAR 2004 H.

Limitatins on Dose Rate (Continued)

B.

lodines and Particulates with Half-Lives Greater than Eight Days in gaseous effluents.

1.

The instantaneous release rate of particulates and iodines is regulated by the dose rate limits of the BFN ODCM. The dose rate at any time to areas at and beyond the site boundary, due to 1-1 31, 1-133, H-3 and particulates with greater than eight days half-lives released in gaseous effluents from the site, shall be limited to < 1500 mrem per year to any organ.

2.

The BFN ODCM Section 7.3 determines the maximum particulate and iodine dose rates.

C.

Liquid Effluents

1. The concentration of radionuclides in liquid effluents released at any time from the site to unrestricted areas shall be limited to the concentrations specified in 10 CFR 20.1001 -

20.2402, Appendix B, Table 2, Column 2 for radionuclides other than dissolved or entrained noble gases.

2. For dissolved or entrained noble gases, the concentration shall be limited to 2E-4 J4Ci per milliliter (ml) total activity.

III.

Measurements and Approximations of Total Radioactivy A.

Fission and Activation Gases:

1. Noble gases in the building vent and stack (elevated) gaseous effluents are continuously monitored. The flow rate of the stack is continuously monitored and the building vent effluent flow rates are calculated once a shift based on the configuration of operating exhaust fans. The vent flow is calculated for each release. Gas grab samples of the stack are taken and analyzed weekly. Gas grab samples of in-service vents are taken and analyzed monthly. The specific noble gas activity concentrations and total volume of the gases are used to calculate the total curies of noble gases released.
2. The tritium concentration is determined by the analysis of a monthly grab sample for each release point.

E3 -3

EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT YEAR 2004 ml.

Measurements and Approximations of Total Radioactivity (continued)

B.

lodines and Particulates I.

lodines and particulates are continuously sampled on impregnated charcoal filters and particulate filters, respectively. The charcoal and particulate samples are replaced at least weekly and analyzed to determine specific activity concentrations. The specific activity concentrations and vent flow rate data are used weekly to verify that release rate limits were not exceeded. The specific activity concentrations and total volume of gaseous effluent are used on a monthly basis to determine the total curies of each particulate and iodine released during the month.

2.

The gross alpha concentration is determined by analysis of a monthly particulate filter composite sample and strontium -89 and -90 are determined by analysis of a quarterly particulate filter composite sample for each release point.

C.

Liquid Effluents

1.

The gamma ray emitting radionuclide concentrations are determined for each batch by gamma ray spectroscopy analysis of a grab sample. The allowable release rate is calculated for each batch based upon the known dilution flow. The flow rate of the liquid effluent is continuously monitored and the total volume released in each batch is determined. The total gamma activity released in each batch is determined by multiplying the radionuclide concentrations by the total volume discharged. The total gamma activity released during the month is then determined by summing the gamma activity content of each batch discharged during the month.

2.

The gross alpha and tritium concentrations are measured on a monthly composite sample.

The strontium -89 and -90 and iron -55 are measured on a quarterly composite sample.

D.

The Radioactive Gaseous and Liquid Waste Monitoring Sampling and Analysis Program is specified in ODCM Sections 1/2.2.1 and 1/2.2.2.

E3 -4

EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SUPPLEMENTAL D;FORMVfATION YEAR 2004 A. Liquid Units

1. Number of batches released Each
2. Total time for batches released Minutes
3. Maximum time period for a batch release Minutes
4. Average time period for a batch release Minutes
5. Minimum time period for a batch release Minutes
6. Average stream flow during period of release into a flowing stream Cubic feet per second Quarter Ouarter Quarter Ouarter 1

2 3

4 0

0 0

0 o

0 0

0 o

0 0

0 o

o 0

0 o

o 0

0 o

o 0

0 B. Gaseous None C. AbnormallUnplanned Releases Type Number of Releases Total Activity Releases (Curies)

None None Liquid Gaseous None None E3-5

EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT LIQUID EFFLUENTS - SUMMIATION OF ALL RELEASES YEAR 2004 Units Ouarter I

A. Fission and Activation Products (Does not include tritium, gases, Alpha)

1. Total Release
2.

Average Diluted Concentration Released During Period

3. Percent of Applicable Limit B. Tritium
1. Total Releases
2. Average Diluted Concentration Released During Period
3.

Percent of Applicable Limit C. Dissolved and Entrained Noble Gases

1. Total Releases
2. Average Diluted Concentration Released During Period
3. Percent of Applicable Limit D. Gross Alpha Radioactivity
1. Total Releases
2. Average Diluted Concentration Released During Period E. Volume of Liquid Waste to Discharge Canal (Prior to dilution)

F. Volume of Dilution Water for Period G. Total CCW Curies NRt gACid NR Curies NR ACiUIS NR Ouarter 2

NR NR NR NR NR NR NR NR NR NR Quarter.

NR NR NR NR

  • N NR NR NR NR NR NR NR uuarter Error N R 9

NR OR 6

NR NR 8

NR NR 48 NR Curies NR JLCi/I/l NR Curies NR LCilml Liters Liters igagallons NR NR NR NR NR NR NR 3

10

  • NR -- No liquid releases were made in the Is' e 3 d and 4 quarters.
    • The applicable limit is expressed in terms of dose. See Enclosure 1, Tables 5 through 8.

E3-6

EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT LIQUID RELEASES FOR YEAR 2004 - BATCH MODE CURIES Isotope Ouarter Quaiter Ouarter Quarter (Required by Regulatory 1

2

_3 4

(REG) Guide 1.21)

1.

Ba-140 NR*

NR NR

2.

Ce-141 NR NR NR NR

3.

Co-58 NR NR NR NR

4.

Co-60 NR NR NR NR S.

Cr-51 NR NR NR NR

6.

Cs-134 NR NR NR NR

7.

Cs-t37 NR NR NR NR

8.

Fe-59 NR NR NR NR

9.

1-131 NR NR NR NR

10.

La-140 NR NR NR NR

11.

Mn-54 NR NR NR NR

12.

Mo-99 NR NR NR NR

13.

Nb-95 NR NR NR NR

14.

Sr-89 NR NR NR NR

15.

Sr-90 NR NR NR NR

16.

Tc-99m NR NR NR NR

17.

Xe-133 NR NR NR NR

18.

Xe-135 NR NR NR NR

19.

Zn-65 NR NR NR NR

20.

Zr-95 NR NR NR NR Others (Not Required by REG Guide 1.21)

NONE

  • NR -

No liquid releases were made during the 1st 2nd 3rd and 4th quarters.

E3 -7

EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT GASEOUS EFFLUENTS - SUMMATION OF ALL RELEASES YEAR 2004 A. Fission and Activation Gases

1. Total Releases
2. Average Release Rate for Period
3. Percent of Applicable Limit B. Iodines
1. Total Iodine-131
2. Average Release Rate for Period
3. Percent of Applicable Limit C. Particulates
1. Particulates with half-lives

> eight days

2. Average Release Rate for Period
3. Percent of Applicable Limit
4. Gross Alpha Radioactivity D. Tritium
1. Total Release
2. Average Release Rate for Period
3. Percent of Applicable Limit Unmits

-Quarter-I Curies 3.84E+00 pCi/sec 4.89E-01 Abuarer 2

ND ND Ouarter 1.54E+01 1.94E+00 Ouarter ND ND ND Error 45 Curies 1.91E-03 5.49E-04 pCi/sec 2.43E-04 6.98E-05 1.1lE-03 1.14E-03 36 1.39E-04 1.44E-04 Curies gCi/sec Curies Curies gCi/sec 1.65E-03

2. 1OE-04 ND**

2.36E+01 3.OOE+00 8.36E-04 1.06E-04 ND 1.03E+01 1.3 1E+00 1.36E-03 1.71E-04 ND 1.20E+01 1.51E+00 1.07E-03 35 1.34E-04 ND 8.81E+00 21 1.1 lE+00

  • Applicable Limits are expressed in terms of dose. See Enclosure 1, Tables 1 through 4.
    • ND - Not Detected.

E3-8

EF CURES

1. Fission Gases Kr-85m Kr-85 Kr-87 Kr-S8 Xe-133 Xe-135m Xe-135 Xe-138 Others (specify)

NONE Total for Period

2.

Iodines 1-131 1-133 Total for Period

  • ND - Not Detected.

FLUENT AND WASTE DISPOSAL ANNUAL REPOR YEAR 2004 GASEOUS EFFLUENTS - ELEVATED RELEASE Ouarter Ouarter Quarter 1

a 3

3.84E+00 ND*

ND ND ND ND ND ND 3.H4E+00 2.36E-04 3.06E-04 5.42E-04 ND ND ND ND ND ND ND ND NM I.96E-04 3.48E-04 5.44E-04 ND ND ND ND 1.54E+01 ND ND ND 1.54E+01 2.75E-04 4.15E-04 6.90E-04 T

Ouarter 4

ND ND ND ND ND ND ND ND ND 2.29E-04 4.19E-04 6.48E-04 E3-9

EFFLUENT AND WASTE D[SPOS t...ANNUAL REPO?

YEAR 2004 GASEOUS EFFLUENTS - ELEVATED RELEASE uarl Quarter Quaatr 1

2 3

CULE

3.

Particulates*

Sr-89 Sr-90 Cs-134 Cs-137 Ba-140 La-140 Others (specify)

Rb-88 Rb-89 Sr-91 Y-91m Cs-138 Ba-139 Au-199 Total m Period*

4.

Tritium 3.03E-05 ND**

ND ND 6.46E-05 2.56E-05 6.32E-02 2.03E-02 8.16E-05 3.30E-04 1.00E-01 5.07E-02 ND 2.35E-01 1.08E+OO 3.52E-05 ND ND ND 8.54E-05 5.43E-05 ND 9.82E-02 6.45E-04 5.28E-04 5.66E-02 7 1OE-02 ND 22E-Q1 1.60E+00 5.51E-05 ND ND ND 7.25E-05 3.62E-05 ND 1.69E-02 7.95E-04 6.52E-04 9.39E-02 9.40E-02 ND 2 07E 01 2.14E+00

>.r Ouarter 4

5.36E-05 ND ND ND 3.73E-05 2.23E-05 ND 5.61E-02 1.67E-04 3.70E-04 8.68E-02 6.14E-02 ND 2.0SE-0I 1.06E+OO

  • Includes all nuclides, even those with less than an eight day half-life.
    • ND - Not Detected.

E3-10

EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT YEAR 2004 GASEOUS EFFLUENTS - GROUND RELEASE CURIES Quarter Quarter er Quarter 1

2 3

4

1. Fission Gases Kr-85m ND*

ND ND ND Kr-85 ND ND ND ND Kr-87 ND ND ND ND Kr-88 ND ND ND ND Xe-133 ND ND ND ND Xe-135m ND ND ND ND Xe-135 ND ND ND ND Xe-138 ND ND ND ND Others (specify)

NONE Total for Period ND ND ND ND

2.

lodines 1-131 7.23E-04 3.59E-05 4.93E-05 1.04E-04 1-132 ND ND ND ND 1-133 9.94E-04 4.09E-05 1.93E-06 1.23E-04 1-135 ND ND ND ND Total for Period 1.72E-03 7268E-05 5.12E-05

.27E-04

  • ND - Not Detected.

E3-11

3. Particulates*

Sr-89 Sr-90 Cs-134 Cs-137 Ba-140 La-140 Others (specify)

EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT YE.AR 2004 GASEOUS EFFLUENTS - GROUND RELEASE Ouarter Quarter Qua 1

2 I

ND**

ND ND ND ND ND ND ND ND ND ND ND 1.00E-05 ND ND ND ND ND Ouarrer ND ND ND ND ND ND ND ND ND ND ND ND ND ND2-0 Cr-51 ND ND Mn-54 1.25E-06 3.33E-06 Co-60 ND ND Sr-91 ND ND Y-91m 1.30E-04 ND Cs-138 1.19E-02 ND Ba-139 2.06E-02 4.90E-03 Total for Period*

3.26E-02 4.90E-03

4.

Tritium 7.03E+00 2

Q

  • Include all nuclides even those with less than an eight day half-life.
    • ND, - Not Detected.

ND ND ND ND ND ND 1.57E-03 1,57E-03 1.88E-+D0 E3-12

EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT YEAR 2004 GASEOUS EFFLUENTS - MIXED MODE RELEASE*

CURIES Ouarter Ouarter Ouarter Ou 1

2 3

4

1.

Fission Gases Kr-85m ND**

ND ND ND Kr-85 ND ND ND ND Kr-87 ND ND ND ND Kr-88 ND ND ND ND Xe-133 ND ND ND ND Xe-135m ND ND ND ND Xe-135 ND ND ND ND Xe-138 ND ND ND ND Others(specify)

NONE Total for Period ND ND ND ND

2.

lodines 1-131 9.51E-04 3.17E-04 7.82E-04 8.09E-04 I-133 6.03E-04 6.22E-04 2.25E-03 2.60E-03 I-135 ND ND ND ND Total for Period 1.55E-03 9,39E-04 3.03E-03 3.41E-03

  • The Reactor Building and Radwaste Building are treated as split-level releases.
    • ND - Not Detected.

E3-13

CURIES

3.

Particulates**

Sr-89 Sr-90 Cs-134 Cs-137 Ba-140 La-140 Others (specify)

Na-24 Cr-51 Mn-54 Co-58 Fe-59 Co-60 Zn-65 Y-91m Sr-91 Sr -92 EFFLUENT AND WASTE DISPOSAL ANNUAL REPOR1 YEAR 2004 GASEOUS EFFLUENTS - MIXED MODE RELEASE*

Ouarter Ouartr 1

2 3

1.97E-05 ND 4.61E-04 5.01E-04 6.43E-05 1.21E-05 ND 1.75E-04 5.66E-05 5.04E-06 1.76E-05 2.03E-04 1.92E-05 7.73E-04 1.45E-04 ND ND***

ND 1.80E-04 3.32E-04 5.64E-06 ND 3.96E-05 ND 1.69E-05 ND ND 6.46E-05 6.OOE-05 1.21E-04 ND 2.15E-03 ND ND 2.03E-04 3.59E-04 4.86E-05 ND 2.44E-04 ND 7.01E-05 1.35E-05 ND 1.95E-04 3.06E-04 1.01E-03 ND ND r

4 ND ND 2.06E-04 3.94E-04 3.87E-05 ND ND ND 2.23E-05 ND ND 1.48E-04 1.66E-04 1.21E-03 ND ND

  • The Reactor Building and Radwaste Building are treated as split-level releases.
    • Includes all nuclides, even those with less than an eight day half-life.
      • ND - Not Detected.

E3-14

EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT YEAR 2004 GASEOUS EFFLUENTS - MIXED MODE RELEASE*

CURIES Particulates** (Continued)

Others (specify)

Mo-99 Tc-99m Quarter ND ND Daadtar 2

ND ND 5.28E-05 ND ND ND 4varLer 4

Ag-110m Cs-138 Ba-139 Au-199 2.14E-05 ND 2.56E-02 ND ND ND 3.68E-05 ND ND ND ND ND ND ND ND ND Total for Period**

2.80E-02 303 E -3 2.48E-03

2. 9E-03
4.

Tritium 154E+Oi 6.21E+00 7.99E+00 6,93E+00

  • The Reactor Building and Radwaste Building are treated as split-level releases.
    • Includes all nuclides, even those with less than an eight day half-life.
      • ND - Not Detected.

E3-15

BROWNS FERRY NUCLEAR PLANT ANNUAL EFFLUENT AND WASTE DISPOSAL REPORT 2004 SOLID WASTE AND IRRADIATED FUEL A.

Solid Waste Shipped Off-site for Burial or Disposal (Not Irradiated Fuel)

1.

Type of Waste Unit Amount Error %

a.

Spent resins, filters, filter sludge m3 1.86E+02 evaporator bottoms, etc.

Ci 1.71 E+03

+/-25.0

b.

Dry compressible waste, contaminated m3 3.12E+03 equipment, etc.

Ci 2.14E+01

+/-25.0

c.

Irradiated components, control rod m3 6.66E+00 blades, filters, LPRMs, IRMs & SRMs Ci 4.25E+04

+1-25.0 with fission chambers, & DAW.

d.

Other - none

2. Estimate of Major Nuclido Composition by Waste Type
a.

Spent resins, filters, filter sludge, evaporator bottoms, etc.

Nuclide Percent Abundance Curies

1)

Fe-55 4.70E+01 8.04E+02

2)

Co-60 1.84E+01 3.15E+02

3)

Cs.137 1.68E+01 2.87E+02

4) Cs-1 34 1.03E+01 1.75E+02
5) Zn-65 3.63E+00 6.21 E+01
6) Mn-54 2.72E+00 4.65E+01
7) Ag-1I Om 5.53E-01 9.46E+00
8) Ni-63 4.29E-01 7.33E+00
9) Cr-51 3.78E-02 6.47E-01
10)

H-3 5.23E-02 8.95E-O1

11)

Sr-90 3.5OE-02 5.98E-01

12)

C-14 2.90E-02 4.96E-01

13)

Pu-241 9.85E-03 1.68E-01

14)

Co-58 7.72E-03 1.32E-01

15)

Fe-59 3.94E-03 6.74E-02

16) Tc-99 1.91 E-03 3.26E-02
17) 1-131 1.85E-03 3.17E-02
18)

Sr-89 1.30E-03 2.23E-02

19)

Cm-242 3.66E-04 6.26E-03

20)

Zr-95 3.47E-04 5.99E-03

21) 1-129 3.50E-04 5.94E-03
22)

Sb-I 24 3.40E-04 5.82E-03

23)

Ce-144 2.69E-04 4.60E-03

24)

Ba-140 2.01 E-04 3.44E-03

25)

La-i 40 1.47E-04 2.51 E-03 E3-16

b.

Dr;, compressible waste, contaminated equipment, etc.

Nuclide Percent Abundance Curies

1) Co-60 4.66E+01 9.98E+00
2) Fe-55 3.61 E+01 7.74E+00
3) Cr-51 3.45E+00 7.40E-01
4) Cs-137 2.97E+00 6.37E-01
5) Mn-54 2.43E+00 5.21 E-01
6) NI-63 2.32E+00 4.98E-01
7) Cs-134 2.24E+00 4.80E-01
8) Pu-241 1.83E+00 3.93E-01
9) Zn-65 1.06E+00 2.28E-01
10)

Fe-69 3.47E-01 7.43E-02

11)

Co-58 2.49E-01 5.34E-02

12)

Ag-110m 1.72E-01 3.69E-02

13)

Am-241 I.01E-01 2.16E-02

14)

Pu-238 B.09E-02 1.30E-02

15)

Pu-239 1.83E-02 3.92E-03

16)

Pu-240 1.83E-02 3.92E-03

17)

Cm-243 9.43E-03 2.02E-03

18)

La-140 9.41 E-03 2.02E-03

19)

Cm-244 9.37E-03 2.01 E-03

20)

Nb-96 8.53E-03 1.83E-03

21)

Zr-95 8.39E-03 1.80E-03

22)

Sb-124 7.67E-03 1.66E-03

23)

Ba-140 6.1SE-03 1.32E-03

24)

C-14 3.58E-03 7.67E-04

25)

Sr-90 3.42E-03 7.33E-04

26) 1-131 2.30E-03 4.92E-04
27)

Ce-144 1.68E-03 3.59E-04

28)

Ce-141 9.78E-04 2.10E-04

29)

Co-57 3.9OE-04 8.35E-05

30)

Cm-242 3.74E-04 8.01 E-05 E3-17

c. Irradiated components, Control Rod Blades, Filters, lRMs, SRMs & LPRMs with fission chambers and DAW.

Nuclides Percent Abundance Curies

1)

Fe-55 5.06E+01 2.15E+04

2)

Co-60 4.36E+01 1.85E+04

3)

Ni-63 3.83E+00 1.63E+O3

4)

Mn-54 1.72E.4-00 7.30E+02

5)

Cs-134 6.54E-02 2.78E+01

6)

Co-58 6.52E-02 2.77E+01

7)

Cs-137 4.83E-02 2.05E+01

8)

Ni-59 2.03E-02 8.62E+00

9)

Zn-65 I.OSE-02 4.48E+00

10)

H-3 6.07E-03 2.581E+00

11)

C-14 6.06E-03 2.57E+00

12)

Ag-il0m 5.80E-03 2.46E+00

13)

Cr-51 3.61 E-03 1.53E+00

14)

Fe-59 2.83E-03 1.20E+00

15)

Sr-90 1.5SE*04 6.56E-02

16)

Sr-89 1.23E.04 5.21 E-02

17)

Sb-124 1.11 E-04 4.69E-02

18)

Zr-95 9.23E-05 3.92E-02

19)

Nb-94 8.89E-05 3.77E-02

20)

Ce-144 3.36E-05 1.43E-02

21)

Tc-99 2.72E-05 1.15E-02

22)

Pu-241 2.09E-05 8.87E-03

23)

Pu-238 1.49E-05 6.33E-03

24)

Ce-141 8.90E-06 3.78E-03

25)

La-140 2.72E-06 1.15E-03

26)

Ba-1 40 1.70E-06 7.20E-04

27)

Cm-242 1.17E-06 4.96E-04

28)

Sb-125 3.08E.07 1.31E-04

29)

Cm-243 1.72E.07 7.29E-05

30)

Sn-1 13 1.36E-07 6.78E-05

31)

Co-57 I.05E-07 4.47E-05

32)

Pu-239 7.33E-08 3.11 E-05

33)

Cm-244 6.88E-08 2.92E-05

34)

Pu-240 1.54E-08 6.52E-06

35)

Arn-241 9.36E-09 3.97E-06

36)

Np-237 1.156E-09 4.88E-07

37)

Am-243 3.82E-10 1.62E-07

38)

U-235 1.72E-1 0 7.28E-08 Percent Curies 1.00E+02 42450.7427 E3-18

3. Solid Waste Disposition
a. Cask Shipments:

Number of Shipments 04 Mode of Transwortation HIC/Cask, Sole Use Truck 3-Irradiated Hardware 1 - Resin Destination Barnwell Waste Management-Barnwell, SC 22 02 HlC/Cask, Sole Use Truck 22 - Resin Cask Sole Use Truck 2-Pump Impellers Duratek Consolidation &

Services Facility-Bamwell, SC Nuclear Services Support Facility-Barnwell, SC

. The 28 cask shipments consisted of the following:

Type oUiHC Numberf Packages Volume Der Package (m3 j 14-170 10 4.84E+00 8-120 14 3.41 E+00 3-55 2

1.63E+00 None 2

1.97E+00 Dis§osal Volume Shipped Lm3l3 4.84E+01 4.77E+01 3.26E+00 3.94E+00 NOTE: The total waste volume of 1.03E+02 m3 consisting of 4.42E+04 curies of activity in casks was all sent directly to burial or processed by a waste processor and then sent to burial during this reporting period. No volume reduction measures were applied to the above wastes by the processor.

b. General Design Packages:

Number of Shipments Mode of Transoortation 51 20 48 - Sole Use Truck 03 - Non Sole Use Truck 00 - Sole Use Truck 20 - Non Sole Use Truck Duratek-Oak Ridge, TN Duratek-Kingston, TN The 71 shipments of waste packaged in general design packages consisted of the following:

Tyve of STC Packages Volume per Package (m3)

Disposal Volume Shirpedfm3 1 40' *Sealand 43 5.89E+01 2.53E+03 20' *Sealando 35 2.94E+01 1.03E+03 Hx Cylinder 2

6.54E+00 1.31 E+01 NOTE: A total waste volume of 3.57E+03 m3 consisting of 3.90E+01 curies of activity was shipped in general design packages to waste processors. The volume is estimated to have been reduced to 2.53E+02 cubic meters by the processors and the curies of activity has remained unchanged.

B.

Irradiated Fuel Disposition Number of ShiDments None Mode of Transportation N/A Destination N/A E3-19

BROWNS FERRY NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT

SUMMARY

OF ABNORMAL/UNPLANNED RELEASES 2004 The release of radioactive material to the environment from Browns Feny has been a small fraction of the 10 CFR 20 Appendix B and 10 CFR 50 Appendix I limits. There were no limits exceeded as specified in 10 CFR 20 Appendix B and 10 CFR 50 Appendix 1.

No abnormal gaseous or liquid releases occurred in 2004.

During the reporting period, January I through December 31, 2004, there were no missed compensatory measures.

There was one missed sample period for Unit 3 reactor zone (mixed mode) gaseous effluent iodines and particulates from April 27, 2004 at 0254 hours0.00294 days <br />0.0706 hours <br />4.199735e-4 weeks <br />9.6647e-5 months <br /> until May 4,2004 at 0358 hours0.00414 days <br />0.0994 hours <br />5.919312e-4 weeks <br />1.36219e-4 months <br />. The charcoal and particulate filter set was found to be missing during the weekly change of the filters on May 04, 2004 (Problem Evaluation Report (PER) 60670). Activity from the filters removed on April 27, 2004 (sample prior to the missing filter set) and May 11, 2004 (sample after the missing filter set) were compared. Both filter sets contained only Cs-137. The highest concentration was from the set removed on April 27, 2004.

The Unit 3 reactor had completed a refueling outage in April and activity was trending down. The April 27, 2004 concentration was included for the missing filter set.

In calendar year 2004, Browns Ferry had no changes to the radwaste system or the Process Control Program (PCP).

E3 -20

ENCL "SURE 4 TENNESSEE VALLEY AUTHORITY BROWNS FERRY NUCLEAR PLANT (BFN)

UNITS 1, 2, AND 3 INOPERABLE RADIOLOGICAL EFFLUENT INSTRUMENTATION REPORT 2004 E4 -1

INOPERABLE RADIOLOGICAL EFFLUENT INSTRUMENTATION REPORT 2004 This report complies with Browns Ferry Nuclear Plant Offsite Dose Calculation Manual (ODCM) Sections 1/2.1.1 and 1/2.1.2. The ODCM requires the exertion of best efforts to return inoperable instruments to operable status within 30 days. Failure to return such instruments to an operable status within the prescribed interval requires a description in the Annual Radioactive Effluent Release Report.

During the reporting period, January I through December 31, 2004, there were no radioactive liquid effluent monitoring instrumentation out of service for greater than 30 days; however, two gaseous effluent monitors were out of service for greater than 30 days. The Unit I Reactor/Turbine/Refuel Building Ventilation Monitor (I-RM-90-250) was inoperable from May 12, 2004 at 2150 hours0.0249 days <br />0.597 hours <br />0.00355 weeks <br />8.18075e-4 months <br /> until July 26, 2004 at 1530 hours0.0177 days <br />0.425 hours <br />0.00253 weeks <br />5.82165e-4 months <br /> and the Unit 3 Reactortlurbine/Refuel Building Ventilation Monitor (3-RM-90-250) was inoperable from November 19, 2004 at 1706 hours0.0197 days <br />0.474 hours <br />0.00282 weeks <br />6.49133e-4 months <br /> through the end of the reporting period. Monitor 3-RM-90-250 was retuned to service on February 1, 2005 at 1830 hours0.0212 days <br />0.508 hours <br />0.00303 weeks <br />6.96315e-4 months <br />. Both monitors' flow measuring systems were inoperable. The flow systems were obsolete and could not be replaced. New flow control systems were designed and installed. All compensatory measures were completed as required.

ODCM Section 1.1.2 requires the radioactive gaseous effluent monitoring instruments alarm/trip setpoints be set in accordance with ODCM section 7.2 to ensure ODCM control limits are not exceeded. During a design review of the ten building gaseous effluent radiation monitoring instruments, it was discovered that the setpoints were set a factor of 60 low since installation in 1991. This included the three Reactor/TurbinelRefuel Building Ventilation Monitors (1, 2 and 3-RM-90-250), the six Turbine Building Ventilation Monitors (1, 2, and 3-RM-90-249 and 1, 2, and 3-RM-90-251) and the Radwaste Building Ventilation Monitor (0-RM-90-252). Monitor flows were recorded in units of cc/sec instead of cc/min as required by the vendor firmware. This resulted in the monitors reading a factor of 60 low. All affected monitors were placed in an inoperable status and compensatory measures were implemented until flow readings could be corrected. A review of data generated since 1991 was completed, and it was determined that no release rate limit was exceeded during the period the setpoints were non-conservative.

Some effluent monitors and flow instrumentation were placed in "out-of-service" status because these monitors' effluent streams were isolated. Therefore, these monitors are not included in this report.

E4-2