Approved By Procedure Number Rev T. W. Cook Ivogelectric Generating
- PlantA 24688-C 16 Date Approved METEOROLOGICAL STATION IOM AMBIENT AND 10-60M DELTA Page Number 09/27/05 TEMPERATURE CHANNEL CALIBRATION I of 71 METEOROLOGICAL STATION 1OM AMBIENT AND 10-60M DELTA TEMPERATURE CHANNEL CALIBRATION PROCEDURE USAGE REQUIREMENTS SECTIONS Continuous Use: Procedure must be open and readily available All Except As at the work location. Follow procedure step by Listed Below step unless otherwise directed by the procedure.
Reference Use: Procedure or applicable section(s) available at Attachment 1 the work location for ready reference by person Attachment 2 performing steps. Attachment 3 Attachment 4 Attachment 5 Attachment 6 Information Use: Available on plant site for reference needed. NONE Printed March 17, 20C6 at 8:20
Approved By 4Procedure Number Rev T.prdW. Cook Vogtle Electric Generating Plant A 24688-C 16 Date Approved METEOROLOGICAL STATION 10M AMBIENT AND 10-60M DELTA Page Number 09/27/05 TEMPERATURE CHANNEL CALIBRATION 2; of 71
'l TABLE OF CONTENTS PAGE 1.0 PURPOSE 3 2.0 PRECAUTIONS AND LIMITATIONS 3 3.0 PREREQUISITES OR INITIAL CONDITIONS 4 4.0 MAIN BODY 7 4.1 CHANNEL CALIBRATION 7 4.1.1 Test Set-Up 7 4.1.2 1OM Ambient Temperature Channel Status Check 9 4.1.3 10-60M Delta Temperature Channel Status Check 9 4.1.4 Ambient Temperature Translator Card Calibration (ATY-55004A) 9 4.1.5 Ambient Temperature Recorder Calibration (ATDR-55004) Red Channel 110 4.1.6 Ambient Temperature Computer Point Calibration Check (T6172) 13 4.1.7 Delta Temperature Translator Card Calibration (ATDY-55004) 14 4.1.8 Delta Temperature Reorder Calibration (ATDR-55004 Blue Channel) 15 4.1.9 Delta Temperature Computer Point Calibration Check (T6174) 18 4.2 SENSOR VERIFICATION (ATE-55004A, ATDE-55005B) 19 4.3 RESTORE TO SERVICE 23 5.0 ACCEPTANCE CRITERIA ,29 6.0 REFER ENCES 30 ATTACHI WIENT 1 LOWERING INSTRUMENT BOOM ASSEMBLY ni ATTACHI WAENT 2 RAISING INSTRUMENT BOOM ASSEMBLY 33 ATTACHI VIENT 3 CHANGING RECORDER SETTINGS C35 ATTACHI WIIENT 4 RECORDER A/D BOARD CALIBRATION 41 ATTACHI WIENT 5 AMBIENT TEMPERATURE TRANSLATOR CALIBRATION 45 ATTACHI W1ENT 6 DELTA TEMPERATURE TRANSLATOR CALIBRATION 51 Printed March 17, 20(6 at 8:20
Approved By . Procedure Number Rev T. W. Cook 0 Vogtle
-I- Electric Generating Plant c : I24688-C 16 Date Approved METEOROLOGICAL STATION 10NlAMBIENT AND 10-60M DELTA Page Number 09/27/05 TEMPERATURE CHANNEL CALIBRATION .3of 71 1.0 PURPOSE 1.1 The purpose of this procedure is to provide instructions for a Channel Calibration of Meteorological Station 1OM Ambient and 10-60M Delta Temperature Loops.
1.2 The performance of this procedure satisfies 10M Ambient and 10-60M Delta Temperature Channel Calibration Surveillance Requirements of VEGP Technical Review Manual TRS 13.3.3.2 Table 13.3.3-1.
13 SCOPE 1.3.1 When this procedure is performed for scheduled Channel Calibration, the following sections shall be used: 1.0, 2.0, 3.0, 4.0 and 5.0.
1.3.2 When this procedure is performed for maintenance, the following sections shall be used: 1.0, 2.0, 3.0, 5.0 and appropriate subsections of 4.0.
2.0 PRECAUTIONS AND LIMITATIONS 2.1 Steps in this procedure may be performed out of sequence only:
2.1.1 With prior approval of the cognizant supervisor. D 2.1.2 If they do not violate the intent of the procedure. u 2.1.3 If they are documented in the "Comments" section of the "Completion Sheet". 0 2.2 Performance of procedure steps, as identified by a double asterisk (t) 3 shall be used when recording data on Data Sheet.
2.3 Any calculations necessary for the performance of this procedure shall be shown on "Calculation Sheet". 0 2.4 The control of lifting wire(s), opening link(s), fuse(s) or jumper(s) will be performed per this procedure. 0 2.5 Guidelines of Procedure 20429-C "Plant Equipment Component Configuration Control" will be used for tagging of wire(s), link(s), fuse(s),
or jumper(s). D Printed March 17, 20)6 at 8:20
Approved By :: , . - i Procedure Nimber Rev T. W. Cook Vogtie Electric Generating Plant i24688-C 16 Date Approved METEOROLOGICAL STATION 10M AMBIENT AND 10-60M DELTA Page Number 09/27/05 TEMPERATURE CHANNEL CALIBRATION t4 of 71 2.6 If this procedure is completed and temporary jumper(s) must remain installed and/or lifted wire(s) cannot be reconnected, a Temporary Modification Request must be completed per Procedure 00307-C, "Temporary Modifications". 0 2.7 This procedure may be performed in any plant operational mode. 0 2.8 If, during performance of this procedure, any of the following occur, immediately notify cognizant supervisor: 0 2.8.1 Any personnel error, procedure inadequacy, or malfunction is identified which could prevent fulfillment of "Acceptance Criteria". 0 2.8.2 Any test exceeds specified limits. u 2.9 If necessary, when maintenance is being performed on the Met Tower instrumentation located in the battery room at the Met Tower, obtain an insulated blanket from the tool room to cover the battery banks while work activities are being performed. Remove covering when work is complete (Do not leave batteries covered for more than one shift). 0 3.0 PREREQUISITES OR INITIAL CONDITIONS 3.1 TEST EQUIPMENT NOTE
- Environmental (temperature, humidity, etc.) compensation for M&TE accuracies may need to be considered.
3.1.1 Two (2) Fluke Model 45 Digital Multimeter (DMM), or equivalent 0 3.1.2 Two (2) General Resistance Model RTD-100 Resistance Temperature Detector (RTD) Simulators, or equivalent 0 3.1.3 Two (2) Reference Thermometers (Resolution of 0.1 0F graduations as a minimum) +0.9 0 F accuracy, or equivalent u 3.1.4 Corning Model PC-351 Hot Plate Stirrer, or equivalent g 3.1.5 Two (2) Temperature Bath g Printed March 17, 20)6 at 8:20
Approved By Procedure N imber Rev T. W. Cook Vogtle Electric Generating plant 24688-C 16 Date Approved METEOROLOGICAL STATION IOM AMBIENT AND 10-60M DELTA Page Number 09/27/05 TEMPERATURE CHANNEL CALIBRATION 5 of 71 3.1.6 Transmation Model 1040 Calibrator or equivalent.
(Required only if recorder A/D board calibration must be performed.) 0 3.1.7 Card Extender for Translator (Required only if adjustments must be made to translator board.) 0 3.1.8 Jumper (Required only if recorder A/D board calibration must be performed.) 0 3.2 MATERIALS REQUIRED 3.2.1 Tape (electrical or duct) used for marking position of boom on lift cable. 0 3.3 Shift Supervisor, or designee, authorization prior to performing work.
TEST STARTED:
DATE TIME SS Signature Date 3.4 Notify Reactor Operator (RO) the following may be erratic or inoperable during performance of this procedure.
Initial 3.4.1 Recorder, ASZR-55002, (Red Channel) "60M Wind Speed" D 3.4.2 Recorder, ASZR-55002, (Blue Channel) "60M Wind Direction" i 3.4.3 Recorder, ATDR-55004, (Green Channel) "10-60M Delta Temperature" D 3.4.4 Computer Point (S6430) "Primary Met Tower 60M Wind Speed" 0 3.4.5 Computer Point (Y6431) "Primary Met Tower 60M Wind Direction" D 3.4.6 Computer Point (T6174) "Primary Met Tower "60-1OM Delta Temp" 0 3.4.7 Recorder ASZR-55000, (Red Channel) "1OM Wind Speed" 0 3.4.8 Recorder ASZR-55000, (Blue Channel) "I OM Wind Direction" 0 Printed March 17, 20)6 at 8:20
Approved By . . Procedure Number Rev T. W. Cook Vogue Electric Generating rIanu ^ - 24688-C 16 Date Approved METEOROLOGICAL STATION 10M AMBIENT AND 10-60M DELTA Page Numbe.
09/27/05 TEMPERATURE CHANNEL CALIBRATION (6 of 71 3.4.9 Recorder ATDR-55004, (Red Channel) "1OM Ambient Temperature" u 3.4.10 Recorder ATDR-55004, (Blue Channel) "Dew Point Temperature" g 3.4.11 Recorder ATDR-55004, (Green Channel) "10-60M Delta Temperature" u 3.4.12 Recorder AZNLR-55003 (Red Channel) "lOM Sigma Theta" 0 3.4.13 Computer Point S6170 "lOM Wind Speed" u 3.4.14 Computer Point Y6171 "1OM Wind Direction" l 3.4.15 Computer Point T6172 "lOM Ambient Temperature" 0 3.4.16 Computer Point T6173 "lOM Dew Point Temperature" 0 3.5 Verify all Prerequisites or Initial Conditions are met.
Initial Printed March 17, 20(6 at 8:20
Approved By : Procedure N imber Rev T. W. Cook Vogue lectric Generating Plant 24688-C 16 Date Approved METEOROLOGICAL STATION IOM AMBIENT AND 10-60M DELTA Page Number 09/27/05 TEMPERATURE CHANNEL CALIBRATION 7 of 71 4.0 MAIN BODY 4.1 CHANNEL CALIBRATION 4.1.1 Test Set-Up 4.1.1.1 (Concurrent Verification required)
Disconnect field leads from Transient Protection Panel, modules 5 and 8, terminals 1, 2, 3 and 4.
Module 5, term 1 Initial CV Initial term 2 Initial CV Ini!ial term 3 Initial CV IniJal term 4 Initial CV Inital Printed March 17, 20)6 at 8:20
Approved By . i P Procedure Number Rev T. W. Cook Vogtle Electric Generang Plant 4688-C 16 Date Approved METEOROLOGICAL STATION 10M AMBIENT AND 10-60M DELTA Page Numbel 09/27/05 TEMPERATURE CHANNEL CALIBRATION 8: of 71 Module 8, term 1 Initial CV Initial term 2 Initial CV Initial term 3 Initial CV Initial term 4 Initial CV Initial 4.1.1.2 Connect one RTD simulator to Transient Protection Panel, module 5, terminals 1, 2, 3 and 4 1 for "1OM Ambient Temperature" input per Figure
- 1. U 4.1.1.3 Connect another RTD simulator to Transient Protection Panel, module 8, terminals 1, 2, 3 and 4 for "10-60M Delta Temperature" input also per Figure 1. El Transient Protedior Panel Module E-K 6)H: RTDSIMULATOR LIz
_E-
- 0 F
4 FLOW NC O LC O00000 K
OLC FLOWC E e 7 7
_ GNC RTD Simulator Connections FIGURE 1 Printed March 17, 2006 at 8:20
Approved By Procedure Number Rev T. W. Cook Vogtle Electric Generating Plant 24688-C 16 Date Approved METEOROLOGICAL STATION 10M AMBIENT AND 10-60M DELTA Page Number 09/27/05 TEMPERATURE CHANNEL CALIBRATION 9 of 71 4.1.2 10M Ambient Temperature Channel Status Check 4.1.2.1 Adjust ambient temperature RTD simulator connected to Transient Protection Panel, module 5 to inputs listed and record indications in "As Found" section of "Data Sheet 1". D 4.1.3 10-60M Delta Temperature Channel Status Check 4.1.3.1 Adjust ambient RTD simulator connected to Transient Protection Panel, module 5 to "50 OF" value listed in "Notes" section of "Data Sheet 2". 0 4.1.3.2 Adjust delta temperature RTD simulator connected to Transient Protection Panel, module 8 to inputs listed and record indications in "As Found" section of "Data Sheet 2". D 4.1.4 Ambient Temperature Translator Card Calibration (A TY-55004A) 4.1.4.1 Remove front panel cover and connect DMM to states block TB4, terminals 10(+) and 11(-). u 4.1.4.2 Adjust ambient temperature RTD simulator connected to Transient Protection Panel, module 5 to input values listed and record output values measured at DMM in "As Found" section of "Data Sheet 3". D 4.1.4.3 If As Found values are within limits specified on "Data Sheet 3", and more accurate values are not desired, proceed as follows:
- a. Record values in "As Left" section of "Data Sheet 3".
- b. Discard "Ambient Test Data Sheet". D
- c. Proceed to appropriate subsection. D 4.1.4.4 If As Found values are not within limits specified on "Data Sheet 3", or more accurate values are desired, perform "Ambient Temperature Translator Calibration" per "Attachment 5. D Printed March 17, 20D6 at 8:20
Approved By Procedure Number Rev T. W. Cook Vogtle Electric Generating Plant A24688-C 16 Date Approved METEOROLOGICAL STATION 10M AMBIENT AND 10-60M DELTA Page Number 09/27/05 TEMPERATURE CHANNEL CALIBRATION 10 of 71 4.1.4.5 If not already performed, connect DMIM to states block TB4, terminals 10(+) and 11(-). u 4.1.4.6 Adjust ambient temperature RTD simulator connected to Transient Protection Panel, module 5 to input values listed and record output values measured at DMM in "As Left" section of "Data Sheet 3". D 4.1.4.7 Disconnect DMM from states block TB4, terminals 10(+) and 11(-). g 4.1.5 Ambient Temperature Recorder Calibration (A TDR-55004 )Red Channel (ATDR-55004, Red Channel) 4.1.5.1 If "As Found" values on "Data Sheet 1" were within tolerance and no adjustments were made per subsection 4.1.4 and more accurate readings are not desired, proceed as follows:
- a. Discard "Data Sheet 4".
Initial
- b. Proceed to appropriate subsection. 0 4.1.5.2 Adjust ambient temperature RTD simulator connected to Transient Protection Panel, module 5 to inputs listed and record indications in "As Found" section of "Data Sheet 4". 0 4.1.5.3 If As Found values are within limits specified on "Data Sheet 4", and
- /* more accurate values are not desired, record values in "As Left" section of "Data Sheet 4" and proceed to appropriate subsection. 0 Printed March 17. 2006 at 8:20
Approved By Procedure Number Rev T. W. Cook N--Vogtle Electric Generating Plant 24688-C 16 Date Approved METEOROLOGICAL STATION IOM AMBIENT AND 10-60M DELTA Page Number 09/27/05 TEMPERATURE CHANNEL CALIBRATION 1lt of 71 4.1.5.4 If As Found values are not within limits specified on "Data Sheet 4", or more accurate values are desired, proceed as follows:
- a. Verify settings of recorder channel 1 per "Attachment 3" and correct as necessary. [1
- b. If calibration of recorder A/D board is not required, proceed to step 4.1.5.5. [
CAUTION
- CH1 and CH2 share one A/D board.
CH 3 and CH4 share another A/D board.
A/D adjustments made for CH1 will affect both CH1 and CH2.
A/D adjustments made for CH2 will affect both CH1 and CH2.
A/D adjustments made for CH3 will affect both CH3 and CH4.
A/D adjustments made for CH4 will affect both CH3 and CH4.
- c. If calibration of recorder A/D board is required for CH1, notify cognizant supervisor calibration of shared channel CH2 "10-60M Delta" per this procedure will also be affected.
- d. (Concurrent Verification required)
Open states block links TB-1 terminal 10 and 11.
TB1, term 10 Initial CV Initial term 11 Initial CV Initial Printed March 17, 2006 at 8:20
Approved By Procedure Number Rev T. W. Cook - 0 ; Electric Generating Plant Vogtle 24688-C 16 Date Approved METEOROLOGICAL STATION 10M AMBIENT AND 10-60M DELTA Page Number 09/27/05 TEMPERATURE CHANNEL CALIBRATION 12 of 71
- e. (Concurrent Verification required)
Open states block links TB-4 terminal 10 and 11.
TB4, term 10 Initial CV Initial term 11 Initial CV Initial
- f. Perform calibration of recorder A/D per "Attachment 4". u
- g. Disconnect voltage source and DMM from states block TB-1, (upper terminals) 10 and 11. 0
- h. Close states block links TB-1 terminal 10 and 11. g
- i. Disconnect test jumper from states block links TB-4 terminal 10 and 11. E
- j. Close states block links TB-4 terminal 10 and 11. u 4.1.5.5 Adjust ambient temperature RTD simulator connected to Transient Protection Panel, module 5 to inputs listed and record indications in "As Left" section of "Data Sheet 4". D Printed March 17, 2006 at 8:20
Approved By . - E t . Procedure Number Rev T. W. Cook VOgte Generating Plant A 24688-C 16 Date Approved METEOROLOGICAL STATION 10M AMBIENT AND 10-60M DELTA Page Number 09/27/05 TEMPERATURE CHANNEL CALIBRATION 1:3 of 71 4.1.6 Ambient Temperature Computer Point Calibration Check (T6172) 4.1.6.1 If "As Found" values on "Data Sheet 1" were within tolerance and no adjustments were made per subsection 4.1.4 and more accurate readings are not desired, proceed as follows:
- a. Discard "Data Sheet 5".
Initial
- b. Proceed to appropriate subsection. 0 4.1.6.2 Adjust ambient temperature RTD simulator connected to Transient Protection Panel, module 5 to inputs listed and record indications in "As Found" section of "Data Sheet 5". g 4.1.6.3 If As Found values are within limits specified on "Data Sheet 5" and more
- /* accurate readings are not desired, record values in "As Left" section of "Data Sheet 5" and proceed to appropriate subsection. u 4.1.6.4 If As Found values are not within limits specified on "Data Sheet 5" or more accurate readings are desired, proceed to 23503-C, "Plant Computer Point Calibration". g 4.1.6.5 After computer adjustment or rework, adjust ambient temperature RTD simulator connected to Transient Protection Panel, module 5 to inputs listed and record indications in "As Left" section of "Data Sheet 5". 0 Printed March 17, 2006 at 8:20
Approved By Procedure Number Rev T. W. Cook Vogtle Electric Generating Plant 24688-C 16 Date Approved METEOROLOGICAL STATION IOM AMBIENT AND 10-60M DELTA Page Numtxr 09/27/05 TEMPERATURE CHANNEL CALIBRATION 1.4 of 71 4.1.7 Delta Temperature Translator Card Calibration (ATDY-55004) 4.1.7.1 Set Ambient RTD simulator connected to Transient Protection Panel, module 5 to "50 OF" value listed in "Notes" section of "Data Sheet 6". 0 4.1.7.2 Connect DMM to states block TB1, terminals 10(+) and 11(-). 1 4.1.7.3 Adjust delta temperature RTD simulator connected to Transient Protection Panel, module 8 to input values listed and record output values measured at DMM in "As Found" section of "Data Sheet 6". u 4.1.7.4 If As Found values are within limits specified on "Data Sheet 6", and more accurate values are not desired, proceed as follows:
- a. Record values in "As Left" section of "Data Sheet 6".
- I*
- b. Discard "Delta Test Data Sheet". 0
- c. Proceed to appropriate subsection. E 4.1.7.5 If As Found values are not within limits specified on "Data Sheet 6", or more accurate values are desired, perform "Delta Temperature Translator Calibration" per "Attachment 6". u 4.1.7.6 Adjust ambient RTD simulator connected to Transient Protection Panel, module 5 to "50 OF" value listed in "Notes" section of "Data Sheet 6". L 4.1.7.7 If not already performed, connect DMM to states block TB1, terminals 0 10(+) and 11(-).
4.1.7.8 Adjust delta temperature RTD simulator connected to Transient Protection Panel, module 8 to input values listed and record output values measured at DMM in "As Left" section of "Data Sheet 6". u 4.1.4.7 Disconnect DMM from states block TB1, terminals 10(+) and 11(-). u Printed March 17, 20)6 at 8:20
Approved By Procedure Number Rev T.prW.Cyook lV ogtle Electric Geenerating Plant 24688-C 16 Date Approved METEOROLOGICAL STATION 10M AMBIENT AND 10-60M DELTA Page Number 09/27/05 TEMPERATURE CHANNEL CALIBRATION 15 of 71 4.1.8 Delta Temperature Recorder Calibration (ATDR-55004, Blue Channel) 4.1.8.1 If "As Found" values on "Data Sheet 2" were within tolerance and no adjustments were made per subsection 4.1.4 or 4.1.7 and more accurate readings are not desired, proceed as follows:
- a. Discard "Data Sheet 7".
Initial
- b. Proceed to appropriate subsection. u 4.1.8.2 If not already performed, adjust ambient RTD simulator connected to Transient Protection Panel, module 5 to "50 OF" value listed in "Notes" g section of "Data Sheet 7".
4.1.8.3 Adjust delta temperature RTD simulator connected to Transient Protection Panel, module 8 to inputs listed and record indications in "As Found" section of "Data Sheet 7". u 4.1.8.4 If As Found values are within limits specified on "Data Sheet 7", and
- /* more accurate values are not desired, record values in "As Left" section of "Data Sheet 7" and proceed to appropriate subsection. u Printed March 17, 2006 at 8:20
Approved By -. . I - Procedure Number Rev T. W. Cook -EVogtle Electric Generating Plant: 24688-C 16 Date Approved METEOROLOGICAL STATION 10M AMBIENT AND 10-60M DELTA Page Numbcr 09/27/05 TEMPERATURE CHANNEL CALIBRATION 16 of 71 4.1.8.5 If As Found values are not within limits specified on "Data Sheet 7", or more accurate values are desired, proceed as follows:
- a. Verify settings of recorder channel 2 per "Attachment 3" and correct as necessary. D
- b. If calibration of recorder A/D board is not required, proceed to step 4.1.8.6. u CAUTION
- CH1 and CH2 share one AND board.
CH 3 and CH4 share another A/D board.
A/D adjustments made for CH1 will affect both CH1 and CH2.
A/D adjustments made for CH2 will affect both CH1 and CH2.
A/D adjustments made for CH3 will affect both CH3 and CH4.
A/D adjustments made for CH4 will affect both CH3 and CH4.
- c. If calibration of recorder A/D board is required for CH2, notify cognizant supervisor calibration of shared channel CH1 "1OM Ambient Temperature" per this procedure will also be affected.
Initial
- d. (Concurrent Verification required)
Open states block links TB-1 terminal 10 and 11.
TB1, term 10 Initial CV Initial term 11 Initial CV Ini:ial Printed March 17, 20)6 at 8:20
Approved By Procedure Number Rev T. W. Cook geElectric eneraLilg Plant 24688-C 16 Date Approved METEOROLOGICAL STATION IOM AMBIENT AND 10-60M DELTA Page Numbur 09/27/05 TEMPERATURE CHANNEL CALIBRATION 17 of 71
- e. (Concurrent Verification required)
Open states block links TB-4 terminal 10 and 11.
TB4, term 10 Initial CV In tial term 11 Initial CV Initial
- f. Perform calibration of recorder A/D per "Attachment 4". g
- g. Disconnect voltage source and DMM from states block TB-1, (upper terminals) 10 and 11. D
- h. Close states block links TB-1 terminal 10 and 11. 0
- i. Disconnect test jumper from states block links TB-4 terminal 10 and 11. n
- j. Close states block links TB-4 terminal 10 and 11. U 4.1.8.6 Adjust delta temperature RTD simulator connected to Transient Protection Panel, module 8 to indications listed and record input values in "As Left" section of "Data Sheet 7". u Printed March 17, 20)6 at 8:20
Approved By G Pa Procedure Number Rev T. W. Cook :'ogtieElectric 24688-C 16 Date Approved METEOROLOGICAL STATION IOM AMBIENT AND 10-60M DELTA Page Number 09/27/05 TEMPERATURE CHANNEL CALIBRATION 18: of 71 4.1.9 Delta Temperature Computer Point Calibration Check (T6174) 4.1.9.1 If "As Found" values on "Data Sheet 2" were within tolerance and no adjustments were made per subsection 4.1.4 or 4.1.7 and more accurate readings are not desired, proceed as follows:
- a. Discard "Data Sheet 8".
Initial
- b. Proceed to appropriate subsection. 0 4.1.9.2 If not already performed, adjust ambient RTD simulator connected to Transient Protection Panel, module 5 to "50 OF" value listed in "Notes" section of "Data Sheet 8". D 4.1.9.3 Adjust delta temperature RTD simulator connected to Transient
- /* Protection Panel, module 8 to inputs listed and record indications in "As Found" section of "Data Sheet 8". 0 4.1.9.4 If As Found values are within limits specified on "Data Sheet 8" and more
- /* accurate readings are not desired, record values in "As Left" section of "Data Sheet 8" and proceed to appropriate subsection. 0 4.1.9.5 If As Found values are not within limits specified on "Data Sheet 8" or more accurate readings are desired, proceed to 23503-C, "Plant Computer Point Calibration". D 4.1.9.6 After computer adjustment or rework, adjust delta temperature RTD simulator for inputs listed and record indications in "As Left" section of "Data Sheet 8". D Printed March 17, 20(6 at 8:20
Approved By Procedure Number Rev T. W. Cook - Vogtle
. Electric Generating Plant 24688-C 16 Date Approved METEOROLOGICAL STATION 10M AMBIENT AND 10-60M DELTA Page Number 09/27/05 TEMPERATURE CHANNEL CALIBRATION 19 of 71 4.2 SENSOR VERIFICATION (ATE-55004A, ATDE-55005B) 4.2.1 Lower instrument boom assemblies and connect test cables per "Attachment 1". 0I 4.2.2 (Concurrent Verification required)
Disconnect 1OM ambient temperature sensor leads.
term 1 Initial CV Initial term 2 Initial CV In tial term 3 Initial CV Initial term 5 Initial CV Initial 4.2.3 Remove sensor from aspirator assembly.
Printed March 17, 20t)6 at 8:20
Approved By Procedure Number Rev T. W. Cook Vogtle Electric'Generating Plant 24688-C 16 Date Approved METEOROLOGICAL STATION 10M AMBIENT AND 10-60M DELTA Page Numbtxr 09/27/05 TEMPERATURE CHANNEL CALIBRATION 20 of 71 4.2.4 (Concurrent Verification required)
Disconnect 60M ambient temperature sensor leads.
term 1 Initial CV Initial term 2 Initial CV In'tial term 3 Initial CV In'tial term 5 Initial CV Initial 4.2.5 Remove sensor from aspirator assembly.
4.2.6 Disconnect RTD simulators connected to Transient Protection Panel, modules 5 and 8. U Printed March 17, 20)6 at 8:20
Approved By Procedure Number Rev T. W. Cook i- ;Vogtle Electric Generating Plant 24688-C 16 Date Approved METEOROLOGICAL STATION 10NM AMBIENT AND 10-60M DELTA Page Number 09/27/05 TEMPERATURE CHANNEL CALIBRATION 21 of 71 4.2.7 Connect ambient temperature sensor leads to Transient Protection Panel, module 5, input terminals 1(E+) to black, 2(E-) to green, 3(1+) to black and 4(1-) to brown. u Transient Protection Panel Module White - _ _ _
__ __ __ __ __ _ __ _ __ __ _ _ __ _ _ __ __ __ _ __ __ __ _ _ _ I E+ I Red I2 E- 2 White Sensor Red 1+ 3 Platinum 4 I- 4 RTD 5 Flow NO 5 6 Flow C 6 7 7 8 8 191 GND. 9 RTD Connections FIGURE 2 4.2.8 Connect delta temperature sensor leads to Transient Protection Panel, module 8, input terminals 1(E+) to black, 2(E-) to red, 3(1+) to black and 4(1-) to white. U 4.2.9 Construct temperature baths at 320 F and 100 0F. Monitor these baths with reference thermometers or equivalent. 0 NOTE When changing temperature baths, allow sufficient time for sensor output to stabilize.
4.2.10 Insert ambient temperature sensor in 320 F bath and record ambient temperature computer point (T6172) indication in "Actual" section of "Data Sheet 9". [
4.2.11 Insert ambient temperature sensor in 1000 F bath and record ambient temperature computer point (T6172) indication in "Actual" section of "Data Sheet 9". 0 Printed March 17, 20)6 at 8:20
Approved By Procedure Number Rev T. W. Cook Vogtle Electric Generating Plant 24688-C 16 Date Approved METEOROLOGICAL STATION 10M AMBIENT AND 10-60M DELTA Page Number 09/27/05 TEMPERATURE CHANNEL CALIBRATION 22 of 71 NOTE During the following steps, ensure that minimal sensor separation is achieved.
4.2.12 Insert both ambient and delta temperature sensors in 320 F bath and record delta temperature computer point (T6174) indication in "Actual" section of "Data Sheet 10". u 4.2.13 Insert both ambient and delta temperature sensors in 100OF bath and record delta temperature computer point (T6174) indication in "Actual" section of "Data Sheet 10". [
4.2.14 Disconnect ambient and delta temperature sensor leads from Transient Protection Panel modules. u 4.2.15 Connect field leads to Transient Protection Panel, modules 5 and 8, terminals 1, 2, 3 and 4. 1 4.2.16 Connect delta temperature sensor leads to 60M aspirator assembly terminal strip that were disconnected in step 4.2.4 and install sensor in aspirator assembly. u 4.2.17 Connect ambient temperature sensor leads to 10M aspirator assembly terminal strip that were disconnected in step 4.2.2 and install sensor in aspirator assembly. El 4.2.18 Disconnect test cables and raise instrument boom assemblies per "Attachment 2". I Printed March 17, 2006 at 8:20
Approved By T. W. Cook Approed B - i :-;Vogdle Electric Genet ating Plant ogeFCrIGeetigPat24688-C' A t 248- 6 Procedure Number Rev 16 Date Approved METEOROLOGICAL STATION IOM AMBIENT AND 10-60M DELTA Page Number 09/27/05 TEMPERATURE CHANNEL CALIBRATION 2.3 of 71 4.3 RESTORE TO SERVICE 4.3.1 Disconnect all test equipment installed during performance of this procedure.
Initial 4.3.2 (Independent Verification required)
If not already performed, disconnect test jumper from states block links TB-4 terminals 10 and 11.
Initial IV Initial 4.3.3 (Independent Verification required)
If not already performed, close the following states block links:
TB-4, term 10 Initial IV Initial term 11 Initial IV Initial TB-1, term 10 Initial IV Initial term 11 Initial IV Initial Printed March 17, 20(6 at 8:20
Approved By Approved By ;Vogffli Electric Generating PlantA -NuneRc
£
- Procedure Nu.tiber Rev T. W. Cook VglElcrc~enringrat24688-C 16 Date Approved METEOROLOGICAL STATION 10M AMBIENT AND 10-60M DELTA Page Number 09/27/05 TEMPERATURE CHANNEL CALIBRATION 24 of 71 4.3.4 (Independent Verification required)
If not already performed, connect field leads to Transient Protection Panel, modules 5 and 8, terminals 1, 2, 3 and 4.
Module 5, term 1 Initial IV Initial term 2 Initial IV Initial term 3 Initial IV Initial term 4 Initial IV Initial Printed March 17, 2006 at 8:20
Approved By Procedure Number Rev T. W. Cook - : SVogtle'Electric Generating Plant 24688-c 16 Date Approved METEOROLOGICAL STATION 10M AMBIENT AND 10-60M DELTA Page Number 09/27/05 TEMPERATURE CHANNEL CALIBRATION 25 of 71 Module 8, term 1 Initial IV Inilial term 2 Initial IV InHiial term 3 Initial IV Initial term 4 Initial IV Init al Printed March 17, 20)6 at 8:20
Approved By Procedure Numbe-r Rev T. W. Cook Vogtle Electric Generating Plant 24688-C 16 Date Approved METEOROLOGICAL STATION IOM AMBIENT AND 10-60M DELTA Page Number 09/27/05 TEMPERATURE CHANNEL CALIBRATION 26 of 71 4.3.5 (Independent Verification required)
If not already performed, connect delta temperature sensor leads to 60M aspirator assembly terminal strip and install sensor in aspirator assembly.
term 1 Initial IV Initial term 2 Initial IV Inihjal term 3 Initial IV InHlial term 5 Initial IV Initial Printed March 17, 2C06 at 8:20
Approved By Procedure Number Rev T. W. Cook Electric Generating
- Plant 24688-C 16 Date Approved METEOROLOGICAL STATION 10M AMBIENT AND 10-60M DELTA Page Number 09/27/05 TEMPERATURE CHANNEL CALIBRATION 27 of 71 4.3.6 (Independent Verification required)
If not already performed, connect ambient temperature sensor leads to 10M aspirator assembly terminal strip and install sensor in aspirator assembly.
term 1 Initial IV Initial term 2 Initial IV Initial term 3 Initial IV Initial term 5 Initial IV Initial 4.3.7 If not already performed, disconnect test cables and raise instrument boom assemblies per "Attachment 2".
Initial Printed March 17, 20C6 at 8:20
Approved By Procedure Number Rev T. W. Cook e Electric Generating ant 24688-C 16 Date Approved METEOROLOGICAL STATION 10N AMBIENT AND 10-60M DELTA Page Numbxr 09/27/05 TEMPERATURE CHANNEL CALIBRATION 23 of 71 4.3.8 Verify recorder date/time and correct as necessary.
Initial 4.3.9 Remove insulated blanket from batteries, if installed.
Initial 4.3.10 Verify loop reflects current plant conditions after it is restored to service.
Initial 4.3.11 Notify RO that Meteorological Station has been returned to service. U 4.3.12 Notify Shift Supervisor, or designee, of completion of work including Test results.
TEST RESULTS ACCEPTABLE Ii UNACCEPTABLE LI CHANNEL RESTORED TO SERVICE LI CHANNEL COMMITED TO REPAIR El TEST COMPLETED:
DATE TIME SS Signature Date 4.3.13 Record the total number of pages used (signatures, initials, data
- I* recorded, etc.) on the "Completion Sheet", and discard remaining. El Printed March 17, 20)6 at 8:20
Approved By Procedure Numnber Rev T. W. Cook vogueElectric enerai~ngPlant 24688-C 16 Date Approved METEOROLOGICAL STATION IOM AMBIENT AND 10-60M DELTA Page Numbcr 09/27/05 TEMPERATURE CHANNEL CALIBRATION 29 of 71 5.0 ACCEPTANCE CRITERIA 5.1 The Acceptance Criteria for this procedure is that all devices listed below are within limits specified on applicable Data Sheets.
5.1.1 Channel Calibration
- a. Ambient Temperature Translator Card ATY-55004A
- b. Ambient Temperature Recorder ATDR-55004 (Red Channel)
- c. Delta Temperature Translator Card ATDY-55004
- d. Delta Temperature Recorder ATDR-55004 (Green Channel)
- e. Computer Point T6172
- f. Computer Point T6174 5.1.2 Ambient Temperature Sensor ATE-55004A 5.1.3 Delta Temperature Sensor ATDE-55005B 5.2 Satisfactory completion of this procedure has been met when cognizant supervisor has evaluated data obtained per Acceptance Criteria of this procedure, reviewed and signed "Completion Sheet" provided.
Printed March 17, 2036 at 8:20
Approved By Procedure Nunber Rev T. W. Cook VgeElcrcGnrating Pan 24688-C 16 Date Approved METEOROLOGICAL STATION 10M AMBIENT AND 10-60M DELTA Page Number 09/27/05 TEMPERATURE CHANNEL CALIBRATION 30 of 71
6.0 REFERENCES
6.1 Met Tower - System Man. - Met Data Col. Center -I.B. - 1X5AG20-0001 6.2 Met Tower - Climatronics Instrumentation Manual, Book 1 - 1X5AG20-0002 6.3 Met Tower - Climatronics Instrumentation Manual, Book 2 - 1X5AG20-0003 6.4 User's Manual Daqstation DX100 (Yokogawa Recorder), 1X5AG20-20000 6.4 Wiring Diagram Meteorological System, AX3D-CH-M50A 6.5 Wiring Diagram Multiplexer Cab and Plant Computer, 1X3D-CE-DO8A 6.6 Wiring Diagram Multiplexer Bay C, 1X3D-CE-D08E 6.7 Multiplexer Field Input Wiring Table, 1X5AB04-186 6.8 Instrument Wire Schematic (Tower and Precipitation),1 X5AG20C-15 6.9 Instrument Wire Schematic (Transient Protection Panel), 1X5AG20C-16 6.10 Instrument Wire Schematic (Panel Rack),1 X5AG20C-18 6.11 Commitments: 892,185,186,10145 6.12 PROCEDURES 6.12.1 00307-C, "Temporary Modifications" 6.12.2 20429-C, "Short Term Documentation Of Temporary Jumpers And Lifted Wires" 6.12.3 23503-C, "Plant Computer Point Calibration" END OF PROCEDURE TEXT Printed March 17, 20(6 at 8:20
Approved By - Procedure Number Rev T. W. Cook - - Vogute Electric Generating Plant 24688-C 16 Date Approved METEOROLOGICAL STATION 10M AMBIENT AND 10-60M DELTA Page Number 09/27/05 TEMPERATURE CHANNEL CALIBRATION 31 of 71 Page 1 of 2 ATTACHMENT 1 REFERENCE USE 1.0 INSTRUCTIONS FOR LOWERING INSTRUMENT BOOM ASSEMBLY 1.1 Inside elevator control box, verify power circuit breaker is pushed in and power indicator lamp is ILLUMINATED. D 1.2 Place 'Heater" switch to the "OFF" position. 0 1.3 Place "Up/Down" switch to the "Down" position. g 1.4 Place winch control "On/Off" switch to the "ON" position. U 1.5 If boom does not begin to lower, toggle "Limit-Override" switch to "Override" position for approximately three seconds. 0 CAUTION
, Bottom limit switch is designed to stop instrument boom at end of travel. If bottom limit switch fails, Instrument Boom will be lowered off tower unless power is not turned off at appropriate time.
1.6 When boom reaches desired position, position winch control "On/Off" switch to "OFF" position. l 1.7 Mark position of instrument boom carriage cable clamps on cable using tape (electrical/duct) to enable proper replacement during restoration. 0 1.8 Remove two cable clamps that attach instrument boom carriage to cable. u CAUTION
. Ensure Dew Point sensor is properly protected during Instrument Boom Carriage removal.
1.9 Push bottom limit switch on left rail track out of the way, then remove instrument boom carriage from rails. u 1.10 Repeat step 1.1 through 1.9 for removal of next instrument boom(s), as appropriate. D Printed March 17, 20)6 at 8:20
Approved By Procedure Number Rev T. W. Cook VoteEeti eeaigPat24688-C' 16 Date Approved METEOROLOGICAL STATION 10M AMBIENT AND 10-60M DELTA Page Number 09/27/05 TEMPERATURE CHANNEL CALIBRATION 32 of 71 Page 2 of 2 ATTACHMENT 1 1.11 Connect one end of test cable to connector on top side of junction box on instrument boom carriage. 0 1.12 Connect other end of test cable to connector on left side of junction box mounted on tower base opposite instrument boom carriage. g Printed March 17, 2J06 at 8:20
Approved By Procedure Number Rev T. W. Cook 0 :Vogtle'Electric Generating Plant 24688-C 16 Date Approved METEOROLOGICAL STATION 10M AMBIENT AND 10-60M DELTA Page Numbcr 09/27/05 TEMPERATURE CHANNEL CALIBRATION 33 of 71 Page 1 of 2 ATTACHMENT 2 REFERENCE USE 1.0 INSTRUCTIONS FOR RAISING INSTRUMENT BOOM ASSEMBLY 1.1 Verify winch control "On/Off" switch is in "OFF" position. 0 1.2 Disconnect test cable from connector on top side of junction box on instrument boom carriage. 0 1.3 Disconnect test cable from connector on left side of junction box mounted on tower base. D 1.4 Place instrument boom carriage on rails and line up carriage with tape (electrical/duct) applied to cable during removal of cable clamps. 0 1.5 Install and tighten cable clamps. 0 1.6 Remove tape (electrical/duct) used to mark cable clamp positions. 0 1.7 Inside elevator control box, verify power circuit breaker is pushed in and power indicator lamp is ILLUMINATED. u 1.8 Place "Up/Down" switch to the "UP" position. 0 1.9 Place winch control "On/Off" switch to the "ON" position. 0 1.10 If boom does not begin to rise, toggle "Limit-Override" switch to "Override" position for approximately three seconds. 0 1.11 Allow drive unit to run until tape (electrical/duct) marking cable instrument boom carriage position is found, then position winch control "On/Off" switch to "OFF" position. u 1.12 Repeat steps 1.4 through 1.11 for installation of next instrument boom(s),
as appropriate. 0 1.13 When all instrument boom carriages have been reattached to cable, place winch control "On/Off" switch to the "ON" position. 0 Printed March 17, 20)6 at 8:20
Approved By 7L -1.Procedure Nu iiber Rev T. W. Cook VogLe LectricGenerating riant 24688-C 16 Date Approved METEOROLOGICAL STATION 10M AMBIENT AND 10-60M DELTA Page Number 09/27/05 TEMPERATURE CHANNEL CALIBRATION 34 of 71 Page 2 of 2 ATTACHMENT 2 1.14 If boom does not begin to rise, toggle "Limit-Override" switch to "Override" position for approximately three seconds. 0 1.15 When instrument boom stops, momentarily toggle "Override" switch to obtain approximately one additional inch of travel to assure instrument boom connector is made up with tower spring loaded connector. 0 1.16 When boom has been raised to desired position, position winch control "On/Off" switch to "OFF" position. 0 1.17 Place "Heater" switch to the ON position. 0 1.18 Verify all contact indicators are ILLUMINATED. 0 Printed March 17, 20K6 at 8:20
Approved By Procedure Number Rev T. W. Cook Vogtle Electric Generating Plant 24688-C 16 Date Approved METEOROLOGICAL STATION IOM AMBIENT AND 10-60M DELTA Page Number 09/27/05 TEMPERATURE CHANNEL CALIBRATION 35 of 71 Page 1 of 6 ATTACHMENT 3 REFERENCE USE 1.0 INSTRUCTIONS FOR CHANGING RECORDER SETTINGS 1.1 Open recorder front cover to access softkeys. 0 1.2 Press "Stop" key to stop data storage. 0 1.3 At "Do you want to stop data storage?" prompt, use "-" "-"arrow keys to highlight "Yes", then press "DISP/ENTER" key. 0 1.4 Verify "STOP" is displayed in red square at top center of display. u1 1.5 Press "Menu" key. 0 NOTE
- The first four top row soft keys correspond to the Menu choices displayed across bottom of screen. The fifth soft key (far right) will display next page of Menu choices, if available.
1.6 At "Set mode" screen, press "#1" softkey (far left) to select "Range, Alarm". [
Printed March 17, 2C06 at 8:20
Approved By l- Procedure T. W. Cook -
Vog2tle Electric Genera ting Plant a, _24688-Date Approved METEOROLOGICAL STATION 10M AMBIENT AND 10-60M DELTA 09/27/05 I TEMPERATURE CHANNEL CALIBRATION Page 2 of 6 ATTACHMENT 3 First-CH: LL Last-CH:
Range Mode Type Range SpanL Span U Scale Volt 5-000 SpanL SpanU :Unit
- :- -20.00 ll120.00D OF Alarm 1 iOff 2 Off 3 Off 4 O~..
ff --
S S S O QID:I) CIZDQIDZCD ED (e (C DC) ED CiD Range - Alarm Screen for Channel No. 1 FIGURE 3 Printed March 17, 20)6 at 8:20
Approved By Procedure Number Rev T. W. Cook i . - Vogtle Electric Generating Plant 24688-C 16 Date Approved METEOROLOGICAL STATION 10M AMBIENT AND 10-60M DELTA Page Number 09/27/05 TEMPERATURE CHANNEL CALIBRATION 37 of 71 Page 3 of 6 ATTACHMENT 3 l ouayo l I First-CH: - ' fjjGag Last-OH:
Range Mode Type Ran ge Span.L.L Span-U IScale] Volt l 6@ 5.000
- Span L- Span U Unit i -10.00 20.00 fI OF Alarm' ,.
1 Off 2 Off 4 Off I.
S S S 54 l
o ID (lID QCIX iDQ (I)D
-C9 (9 GDQD QI~D Range - Alarm Screen for Channel No. 2 FIGURE 3A 1.7 At "Range - Alarm" screen, use "A", "V", "4", "'-" arrow keys to El highlight "First-CH:" field.
1.8 Select desired channel (01, 02, 03, or 04) by pressing corresponding softkey. El 1.9 Verify channel number selected is displayed in "First-CH:" field. [1 1.10 Il the "Mode" or'Type" field settings are correct, proceed to step 1.12 El 1.11 li the "Mode" or'Type" field settings are not correct proceed to as follows:
Printed March 17, 2006 at 8:20
Approved By :. 4 Procedure Number Rev T. W. Cook VogtleEl!ectric
". (Reference Figure 4) El 1.15.4 Press "DISP/ENTER" key to move cursor right and highlight (-) minus sign. LI 1.15.5 To retain (-) minus sign, while (-) minus sign is highlighted, use "A" "v" "4" "-" arrow keys to highlight (-), then press "DISP/ENTER" to move cursor right. LI Printed March 17, 2006 at 8:20
Approved By Procedure Number Rev T. W. Cook - Vogtle Electric Generating Plant 24688-c 16 Date Approved METEOROLOGICAL STATION 10M AMBIENT AND 10-60M DELTA Page Number 09/27/05 TEMPERATURE CHANNEL CALIBRATION 40 of 71 Page 6 of 6 ATTACHMENT 3 1.15.6 To delete (-) minus sign, while (-) minus sign is highlighted, use "A" "v" "4" "-" arrow keys to highlight "Sp", then press "DISP/ENTER" key to move cursor right. u 1.15.7 Use "A" "V""-" "-" arrow keys to select new value for highlighted digit, then press "DISP/ENTER" key accept highlighted digit and move cursor right. ° 1.15.8 Repeat steps 1.15.7 to change remaining digits within field. 0 1.15.9 When all digits and (-) minus sign in field have been changed, use "A" "V' "4" "9" arrow keys to highlight "ENT", then press "DISP/ENTER" key to enter changes in "Range - Alarm" screen. [
1.15.10 At "Range - Alarm" screen, verify new numeric value is displayed in field and highlighted in yellow. 0 1.15.11 Press "DISP/ENTER" key to save changes and verify correct numeric value is displayed in field and is no longer highlighted. 0 1.16 Repeat steps 1.15 through 1.15.11 until "Span-L", "Span-U", "ScaleL",
or "Scale U" field settings are correct. 0 1.17 If the "Unit" field setting is correct, proceed to step 1.19. 0 1.18 If the "Unit" field setting is not correct, navigate through "Unit" Menu similar as steps 1.15 through 1.15.10 except change unit settings instead of numeric values. 0 1.19 Repeat steps 1.7 through 1.18 for remaining recorderchannels. 0 1.20 When all channels have been verified, press "START" softkey and verify red "STOP" square at to center of display changes to green with flashing "T"and chart grid is displayed on screen. 0 Printed March 17, 2C06 at 8:20
Approved By Procedure Number Rev T. W.Cook : VogtleElectric Generating Plant 24688-c 16 Date Approved METEOROLOGICAL STATION 10M AMBIENT AND 10-60M DELTA Page Number 09/27/05 TEMPERATURE CHANNEL CALIBRATION 41 of 71 Page 1 of 3 ATTACHMENT 4 lREFERENCE USE 1.0 CALIBRATION OF YOKOGAWA RECORDER A/D BOARD 1.1 If performing calibration of CH1 or CH2, proceed as follows:
1.1.1 Connect test jumper across TB-4 (upper terminals) 10 (+) and 11 (-) to provide zero input to CH1 and CH2 A/D board. LI 1.1.2 If not already performed, connect voltage source and DMM across TB-1 (upper terminals) 10(+) and 11(-) to provide full scale input to CH1 and CH2 A/D board per Figure 5. U FIGURE 5 1.2 Assure recorder environment is maintained at 73.4 OF +/- 9 OF during calibration. LI Printed March 17, 2C06 at 8:20
Approved By Procedure Number Rev T. W. Cook Vogtle Electric Generating Plant 24688-C 16 Date Approved METEOROLOGICAL STATION 10M AMBIENT AND 10-60M DELTA Page Number 09/27/05 TEMPERATURE CHANNEL CALIBRATION 42 Of 71 Page 2 of 3 ATTACHMENT 4 1.3 Press door latch and open recorder door to access recorder ON/OFF switch per Figure 6. 1I ON/OFF swtich locatec Door Latch behind Door j 9(C~D CII 0(1C) E FIGURE 6 1.4 If not already performed, turn ON recorder and allow warm-up period of at least 30 minutes. ;
1.5 Enter "Calibration Mode" as Follows:
1.5.1 Turn OFF recorder.
1.5.2 Press and hold the "A" arrow key and the "DISP/ENTER" key.
1.5.3 Press and release recorder power ON switch to turn recorder ON. ]
1.5.4 Continue to hold "A" arrow key and "DISP/ENTER" key until "Calibration Mode" screen is displayed. I]
1.6 For calibration of CH1 and CH2, select "01-02" by pressing corresponding softkey, then press "DISP/ENTER" button. ]
1.7 At next screen, select "#2 Cal/Exec" by pressing "#2" softkey.
("#2" softkey is top row, second from left.) ]
1.8 At "AND adjust range" screen, select "Next 1/2" by pressing far right softkey. ]
1.9 For 0 to 5 V DC range, select "6V" by pressing corresponding softkey and observe "6V" is highlighted next to "A/D adjust range".
Printed March 17, 20(6 at 8:20
Approved By Procedure Number Tpprwed~
Ok l 0 Vogtle Electric Gener'ating:Planit a 48-. 1Rev T. W. Cook VLc 2ILI 24688-C! 16 Date Approved METEOROLOGICAL STATION IOM AMBIENT AND 10-60M DELTA Page Number 09/27/05 TEMPERATURE CHANNEL CALIBRATION 43 of 71 1.10 Adjust voltage source connected to CF12 input to 6.000 V DC. [
1.11 Allow calibration value to stabilize, then press "DISP/ENTER" key. 0 1.12 Press "ESC" softkey to return to previous screen. u 1.13 Select "#3 End" by pressing corresponding softkey. l 1.14 To save changes, at the "Do you really want to save A/D adjust value?"
prompt, press "-4" or "-" arrow key to highlight "YES", then press "DISP/ENTER" key. o Printed March 17, 20(6 at 8:20
Approved By Procedure Number Rev T. W. Cook : f I:Vogtle.Electric Generating Plant 24688-C 16 Date Approved METEOROLOGICAL STATION 10M AMBIENT AND 10-60M DELTA Page Number 09/27/05 TEMPERATURE CHANNEL CALIBRATION 441 of 71 Page 3 of 3 ATTACHMENT 4 1.15 Turn recorder OFF to exit Calibration Mode. D 1.16 Turn recorder ON to return recorder display to normal screen. u 1.17 Return to appropriate recorder calibration subsection to reconnect field leads and to obtain "As Left" readings. 0 1.15 Turn recorder OFF to exit Calibration Mode. 0 1.16 Turn recorder ON to return recorder display to normal screen. D 1.17 Return to recorder calibration step 4.1 .5.4g or 4.1 .8.5g as appropriate. u Printed March 17, 2006 at 8:20
Approved By Procedure Number Rev T. W. Cook VofeEeti eeaig Plnt 24688-C 1 Date Approved METEOROLOGICAL STATION IOM AMBIENT AND 10-60M DELTA Page Numbe.
09/27/05 TEMPERATURE CHANNEL CALIBRATION 45 of 71 Page 1 of 5 ATTACHMENT 5 I REFERENCE USE 1.0 CALIBRATION OF AMBIENT TEMPERATURE TRANSLATOR 1.1 Remove translator card from card frame and place on card extender, then reinstall. D 1.2 If not already performed, place front panel calibration switch to "Oper." El position.
NOTE Room temperature must be maintained within +/- 1.8 'F throughout test.
1.3 Measure and record Room temperature on "Ambient Test Data Sheet". El 1.4 If not already performed, disconnect field leads and connect Ambient RTD simulator to Transient Protection Panel, module 5, terminals 1, 2, 3 and 4 per subsection 4.1. El Module 5 Color Function Terminal 1 Red +E El Terminal 2 Black -E El Terminal 3 Red +1 El Terminal 4 Black -I 0 1.5 Connect a DMM set to read V DC across R8. D 1.6 Connect a DMM set to read V DC across TP10 and TP1 (Gnd). El Printed March 17, 2006 at 8:20
Approved By Procedure Number Rev T. W. Co ok l- : X i0Vogtle Electric Generating Plant .24688-C 16 Date Approved METEOROLOGICAL STATION IOM AMBIENT AND 10-60M DELTA Page Number 09/27/05 TEMPERATURE CHANNEL CALIBRATION 46 of 71 Page 2 Of 5 ATTACHMENT 5 R2 R5 R29 R32 T~q4 3 mROt- P&TP2 MTP6 1 1 IDCS CQ TP1 Bk (Ground) z L~,
1 12 y; CI TF 2 ~ 4 1TP2Org (Output-Full Scale,'
- ,,V4 I -
1 g TP3 Gm (Output-Padded)
R P8 2 R4 C17 R TP4 Blue (T Ref Out)
<(8 Z)U 09 t 4 : (Not
]Wht Used)
R8 TP1U FIGURE 7 1.7 Set Ambient RTD simulator to "-58 0F" value listed on 'Test Data Sheet"
- /* and record As Found reading across R8 in "I Input Zero" section of "Ambient Test Data Sheet".
1.8 Record DMM reading at TP10 in As Found "V Zero" section of "Ambient
- /* Test Data Sheet".
1.9 Set Ambient RTD simulator to "122 OF" value listed on "Ambient Test Data Sheet" and record As Found reading across R8 in "I Input Span" section of "Ambient Test Data Sheet". 0 1.10 Record DMM reading at TP10 in As Found "V Span" section of "Ambient Test Data Sheet". 0 Printed March 17, 20)6 at 8:20
Approed ByProcedure Nuriber Rev T. W.Cook24688-C 16 Date Approved METEOROLOGICAL STATION 10M AMBIENT AND 10-60M DELTA Page Number 09/27/05 TEMPERATURE CHANNEL CALIBRATION 47 of 71 Page 3 of 5 ATTACHMENT 5 1.11 Using values recorded in steps 1.8, 1.9, and 1.10, calculate new value for voltage across R8 (I Input Span) as follows:
VzO = Step 1.8 Zero reading at TP10 VR8 = Step 1.9 I Input Span reading across R8 Vspaf = Stepl.10 Span reading at TP10 New VR,3 =Old VR8 x 0.01228 (100)
Vspan - Vzrero 1.12 If not already performed, set Ambient RTD simulator to "122 OF" value on "Ambient Test Data Sheet". D 1.13 Adjust R32 (RTD current input adj.) until DMM across R8 reads voltage value obtained per calculation. g 1.14 Adjust R29 (Offset adj) until DMM across TP10 reads Expected "V Span" value listed on "Ambient Test Data Sheet". 0 1.15 Set Ambient RTD simulator to "-20 OF" value listed on "Ambient Test Data Sheet" and record As Found reading at TP10 in "Zero" section of 0 "Ambient Test Data Sheet".
1.16 Set Ambient RTD simulator to "+120 IF" value listed on "Ambient Test Data Sheet" and record As Found reading at TP10 in "Full Scale" section of "Ambient Test Data Sheet". 0 1.17 If readings obtained in step 1.15 and 1.16 are within limits on "Ambient Test Data Sheet", proceed to step 1.19. 0 1.18 If readings obtained in step 1.15 and 1.16 are not within limits on "Ambient Test Data Sheet", repeat steps 1.7 through 1.16. u 1.19 Disconnect DMM's from across R8 and from PT1O & TP1. g 1.20 Connect DMM set to read V DC across TP2 and TP1 (Gnd) 0 Printed March 17, 20)06 at 8:20
Approved By Procedure Number Rev T.W. Cook - Vogtle Electric Generating Plant 24688-C 16 Date Approved METEOROLOGICAL STATION IOM AMBIENT AND 10-60M DELTA Page Number 09/27/05 TEMPERATURE CHANNEL CALIBRATION 48 of 71 Page 4 of 5 ATTACHMENT 5 1.23 Set Ambient RTD simulator to "-20 OF" value listed on "Ambient Test Data Sheet" and record As Found reading at TP2 in "Output Zero" section of "Ambient Test Data Sheet". u 1.24 Set Ambient RTD simulator to "+120 OF" value listed on "Ambient Test Data Sheet" and record As Found reading at TP2 in "Output Span" section of "Ambient Test Data Sheet". D 1.25 If output readings obtained in step 1.23 and 1.24 are within limits, proceed to step 1.32. i 1.26 If output readings obtained in step 1.23 and 1.24 are not within limits "Ambient Test Data Sheet", proceed to step 1.27. D 1.27 Set Ambient RTD simulator to "-20 OF" value listed on "Ambient Test Data Sheet". D 1.28 Adjust R49 until DMM connected to TP2 and TP1 reads "Output Zero" value listed on "Ambient Test Data Sheet". D 1.29 Set Ambient RTD simulator to "120 OF" value listed on "Ambient Test Data Sheet". D 1.30 Adjust R41 until DMM connected to TP2 and TP1 reads "Output Span" value listed on "Ambient Test Data Sheet". I 1.31 Repeat steps 1.27 through 1.30 until "Output Zero" and "Output Span" readings across TP2 and TP1 are within limits on "Ambient Test Data Sheet". D 1.32 Place front panel calibration switch to "Zero" position. D 1.33 Adjust R2 until DMM connected to TP2 and TP1 reads 0.000 V DC. D 1.34 Place front panel calibration switch to "Span" position. D 1.35 Adjust R5 until DMM connected to TP2 and TP1 reads 5.000 V DC. D 1.36 Position front panel calibration switch to "Operate" position. D Printed March 17, 2036 at 8:20
Approved By . E - Procedure Number Rev T. W. Cook vogue E r enerating rIani 24688-C 16 Date Approved METEOROLOGICAL STATION 10M AMBIENT AND 10-60M DELTA Page Number 09/27/05 TEMPERATURE CHANNEL CALIBRATION 49 of 71 Page 5 of 5 ATTACHMENT 5 1.37 Disconnect DMM's connected to translator card. 0 1.38 Remove translator card and card extender from card frame and reinstall translator card in card frame. 0 1.39 "Ambient Test Data Sheet" may be discarded. D 1.40 Return to appropriate translator subsection to obtain "As Left" reading. 0 Printed March 17. 2(06 at 8:20
Approved By C r X C
Procedure Number Rev T. W. Cook I Vogtle Electric Generating Plant A 0 I 24688-C 16 Date Approved METEOROLOGICAL STATION 10M AMBIENT AND 10-60M DELTA TEMPERATURE CHANNEL CALIBRATION Page Number 09/27/05 1 50 of 71 SHEET 1 OF 1 pr% I I Mq.g IIVIL.Ii I ii AMBIENT TEST DATA SHEET
Title:
Ambient Temperature Translator NOTES: This sheet is used only when adjustments to the Ambient Temperature Translator card are required and may be discarded after use or if not needed.
Values calculated for Signal conditioner serial number 338 which is matched to RTD serial number 4018608.
READING ACROSS R8 X . - :
PARAMETER TEMPERATURE - INPUT, EXPECTED LO LIMIT- Hi LIMIT AS FOUND Room Temperature OF
.- O'_:___
F :' OHMS VDC - V DC V DC VDC I Input Zero -58.0 80.299 l-A NIA N/A _
IlnputSpan 122.0 119.411 NIA N.IA WNA-_ ___
READINGS ATTP1o AND TP1(GNfl, -
PARAMETER TEMPERATURE INPUT--- --EXPECTED LO LIMIT Hi LIMIT AS FOUND
- F OHMS VDC .VDC. . DC- VDC V zero -58.0 80.299 0.0000 -0.0001 0.0001 V span +122.0 119.411 1.2280 1.2279 1.2281 Zero -20.0 88.658 0.25924 0.2591 0.2593 Full Scale +120.0 118.983 1.2143 1.2142 1.2144 READINGS ATTP2 AND TP1(GND) ' ' _' : ' '.'":
PARAMETER TEMPERATURE '-INPUT.:-,'- EXPECTED LO LIMIT- Hi LIMIT. AS FOUND
- , .OHMSI:DCJ i: DC V VDC Output zero -20.0 88.658 0.000 -0.001 0.001 _
Output span +120.0 118.983 5.000 4.999 5.001
%.p%,#211V1.1VI %.P.
Printed March 17, 2006 at 8:20
Approved By Procedure Number Rev T. W. Cook Electric Generating Plant 28 24688-C 116 Date Approved METEOROLOGICAL STATION IOM AMBIENT AND 10-60M DELTA Page Number 09/27/05 TEMPERATURE CHANNEL CALIBRATION 51 of 71 Page 1 of 5 ATTACHMENT 6 I REFERENCE USE l 1.0 CALIBRATION OF DELTA TEMPERATURE TRANSLATOR 1.1 Remove translator card from card frame and place on card extender, then reinstall.
1.2 If not already performed, place front panel calibration switch to "Oper." 3El position.
NOTE
- Room temperature must be maintained within +/- 1.8 'F throughout test.
1.3 Measure and record Room temperature on "Delta Test Data Sheet". El 1.4 If not already performed, disconnect field leads and connect Ambient RTD simulator to Transient Protection Panel, module 5, terminals 1, 2, 3 and 4 per subsection 4.1. El Module 5 - : Color Function - -
Terminal 1 Red +E Terminal 2 Black -E 3El Terminal 3 Red +1 El Terminal 4 Black -I El 1.5 Set Ambient RTD simulator connected to Transient Protection Panel, module 5, to approximately 100 ohms. El 1.6 If not already performed, disconnect field leads and connect Delta RTD simulator to Transient Protection Panel, module 8, terminals 1, 2, 3 and 4 per subsection 4.1. El
- Module 5 m i Color - ; IFunction I-Terminal 1 Red +E El Terminal 2 Black -E U1 Terminal 3 Red +1 ]
Terminal 4 Black -I ]1 Printed March 17, 2006 at 8:20
Approved By T.W. Cook Vogtle Electric Genera"ing e24688-CPlant :
AProcedure Number Rev 16 Date Approved METEOROLOGICAL STATION 10M AMBIENT AND 10-60M DELTA Page Number 09/27/05 TEMPERATURE CHANNEL CALIBRATION 52 of 71 Page 2 of 5 ATTACHMENT 6 1.7 Connect a DMM set to read V DC across R8. [1 1.8 Connect a DMM set to read V DC across TP10 and TP1 (Gnd). u FR2 R5 R29 R32 t49 lt T2Vqw% R cn' Ci TP1 & TP2
=cT i46 TP2 Org utputF ll (Ground)
IT 2C1 R
____ R II~ TP Blue TP3 Gm (OuRefput)Fl (Output-Padded)cl'
= R C CR1 ,1 tlR7 TP4 Blue (TRef Out)
=: We Wht (Not Used)
_ /Z4 ,
7 WW H T3E02 EL R8 TP10 1.9 Set Delta RTD simulator connected to Transient Protection Panel, module 8, to "-58 OF" value listed on "Delta Test Data Sheet" and record As Found reading across R8 in "I Input Zero" section of "Delta Test Data Sheet". ° 1.10 Record DMM reading at TP1 0 in As Found "V Zero" section of "Delta Test Data Sheet". E1 1.11 Set Delta RTD simulator to "140 OF" value listed on "Delta Test Data Sheet" and record As Found reading across R8 in "I Input Span" section of "Delta Test Data Sheet". [1 Printed March 17, 20)6 at 8:20
Approved By Procedure Nu nber Rev T. W.Cyook l Vogtle Electric Generating Plant 24688-C 16 Date Approved METEOROLOGICAL STATION 10M AMBIENT AND 10-60M DELTA Page Number 09/27/05 TEMPERATURE CHANNEL CALIBRATION 53 of 71 Page 3 of 5 ATTACHMENT 6 1.12 Record DMM reading at TP10 in As Found "V Span" section of "Delta Test Data Sheet". 0 1.13 If "As Found" V Zero" and "V Span" readings at TP10 are within limits on "Delta Test Data Sheet" proceed to step 1.19. E 1.14 If "As Found" V Zero" and "V Span" readings at TP10 are not within limits on "Delta Test Data Sheet" proceed to step 1.15. I 1.15 Using values recorded in steps 1.10, 1.1 1, and 1.12, calculate new value for voltage across R8 as follows:
Vzro = Step 1.10 Zero reading at TP10 VR8 = Stepl.11 I InputSpanreadingacross R8 Vs,,, = Step 1.12 SpanreadingatTP10 New V~r8 = Old VR8X 0.01228(100)
Vspan - Vzrero 1.16 If not already performed, set Delta RTD simulator to "140 OF" value on "Delta Test Data Sheet". 0 1.17 Adjust R32 (RTD current input adj.) until DMM across R8 reads voltage value obtained per calculation. 0 1.18 Adjust R29 (Offset adj) until DMM across TP10 reads Expected "V Span" value listed on "Delta Test Data Sheet". u 1.19 Set Delta RTD simulator to "-30 OF" value listed on "Delta Test Data Sheet" and record As Found reading at TP10 in "Zero" section of "Delta Test Data Sheet". D 1.20 Set Delta RTD simulator to "+140 OF" value listed on "Delta Test Data Sheet" and record As Found reading at TP10 in "Full Scale" section of "Delta Test Data Sheet". 0 1.21 If readings obtained in step 1.19 and 1.20 are within limits on "Delta Test Data Sheet", proceed to step 1.23. E Printed March 17. 2006 at 8:20
Approved By Procedure Number Rev T. W. Cook VogtleElectricGeneratingPlant 24688-C 16 Date Approved METEOROLOGICAL STATION IOM AMBIENT AND 10-60M DELTA Page Number 09/27/05 TEMPERATURE CHANNEL CALIBRATION 54 of 71 Page 4 of 5 ATTACHMENT 6 1.22 If readings obtained in step 1.19 and 1.20 are not within limits on "Delta Test Data Sheet", repeat steps 1.9 through 1.20 as required. D 1.23 Disconnect DMM's from across R8 and from TP10 & TP1. D 1.24 Connect DMM set to read V DC across TP2 and TP1 (Gnd) D 1.25 Set Ambient RTD simulator to "-20 OF" value listed in "Notes" section of "Delta Test Data Sheet". D 1.26 Set Delta RTD simulator to "-30 OF" value listed on "Delta Test Data Sheet" and record As Found reading at TP2 in "Output Zero" section of "Delta Test Data Sheet". D 1.27 Set Ambient RTD simulator to "120 OF" value listed in "Notes" section of "Delta Test Data Sheet". D 1.28 Set Delta RTD simulator to "140 0F" value listed on "Delta Test Data Sheet" and record As Found reading at TP2 in "Output Span" section of "Delta Test Data Sheet". D 1.29 If output readings obtained in step 1.26 and 1.28 are within limits on "Delta Test Data Sheet", proceed to step 1.38. D 1.30 If output readings obtained in step 1.26 and 1.28 are not within limits on "Delta Test Data Sheet", proceed to step 1.31. D 1.31 Set Ambient RTD simulator to "-20 OF' value listed in "Notes" section of "Delta Test Data Sheet". D 1.32 Set Delta RTD simulator to "-30 OF" value listed on "Delta Test Data Sheet". D 1.33 Adjust R49 until DMM connected to TP2 and TP1 reads "Output Zero" value listed on "Delta Test Data Sheet". g 1.34 Set Ambient RTD simulator to "120 0F" value listed in "Notes" section of "Delta Test Data Sheet". D 1.35 Set Delta RTD simulator to "140 OF" value listed on "Delta Test Data Sheet". D Printed March 17, 2C06 at 8:20
Approved By Procedure Number Rev T. T. W. Cook Cok268C W. Vogtle Electric Generalting Plant'268C 11 Date Approved METEOROLOGICAL STATION IOM AMBIENT AND 10-60M DELTA Page Number 09/27/05 TEMPERATURE CHANNEL CALIBRATION 55 of 71 Page 5 of 5 ATTACHMENT 6 1.36 Adjust R41 until DMM connected to TP2 and TP1 reads "Output Span" value listed on "Delta Test Data Sheet". U 1.37 Repeat steps 1.31 through 1.36 until "Output Zero" and "Output Span" readings across TP2 and TP1 are within limits on "Delta Test Data Sheet". D 1.38 Place front panel calibration switch to "Zero" position. a 1.39 Adjust R2 until DMM connected to TP2 and TP1 reads 0.000 V DC. D 1.40 Place front panel calibration switch to "Span" position. 0 1.41 Adjust R5 until DMM connected to TP2 and TP1 reads 5.000 V DC. 0 1.42 Position front panel calibration switch to "Operate" position. a 1.43 Disconnect DMM's connected to translator card. u 1.44 Remove translator card and card extender from card frame and reinstall translator card in card frame..
1.45 "Delta Test Data Sheet" may be discarded. D 1.46 Return to appropriate translator subsection to obtain "As Left" reading. D Printed March 17, 2C06 at 8:20
Approved By
'7 C Nher N~Pocdr Rev T. W. Cook Vogtle Electric Generating Plant A 24688-C P 16 Date Approved METEOROLOGICAL STATION 10M AMBIENT AND 10-60M DELTA TEMPERATURE CHANNEL CALIBRATION Page Number 09/27/05 56 of 71 SHEET 1 OF 1 HI *4%.01 N.VILiiW DELTA TEST DATA SHEET
Title:
Delta Temperature Translator NOTES: This sheet is used only when adjustments to the Ambient Temperature Translator card are required and may be discarded after use or if not needed.
Set 1OM ambient temperature RTD simulator to 88.658 ohms for -20.0 OF.
Set 1OM ambient temperature RTD simulator to 118.983 ohms for 120.0 OF.
Ambient Signal conditioner serial number 338 is matched to RTD serial number 4018608.
Translator card Serial No.341 is matched with RTD Serial No. 4018607.
READING ACROSS R8 ' ^ :- X -'-:--:_-
-PARAMETER -- TEMPERATURE --- INPUTS-'EXPECTED., LO LIMIT- ---HI LIMIT- -AS FOUND Room Temperature OF OF -OHMS V DC V DC - V-DC---- V DC COMMENTS:
I Input Zero -58.0 80.297 WNA' NIA NI En____N/_A-I Input Span 140.0 123.286 NIA NIA - N/A ____
READINGS AT TP1 -AND TP------ - :, _ _ , ___-
PARAMETER __ TEMPERATURE INPUT- - EXPECTED- LO LIMIT Hi LIMIT - AS FOUND
-_-__F : OHMS VDC VDC VDC V DC V zero -58.0 80.297 0.0000 -0.0001 0.0001 V span +140.0 123.286 1.3508 1.3507 1.3509 Zero -30.0 86.466 0.1910 0.1909 0.1911 Full Scale +140.0 123.286 1.3508 1.3507 1.3509 READINGS ATTP2 AND TP1(GND) - - -_' '_-'_
PARAMETER__ TEMPERATURE INPUT EXPECTED LO LIMIT HI LIMIT AS FOUND
_- ____ _----_ OHMS -VDC VDC V DC j VDC Output zero -30.0 80.297 0.000 -0.001 0.001 Output span +140.0 123.286 5.000 4.999 5.001 Printed March 17, 2006 at 8:20
/I-t C
- Vogtle Electric Generating Plant A SHEET 1 OR 2 DA A SncE T .
Meteorological Station
Title:
Meteorological Station 1OM Ambient Temperature NOTES: Red Channel DEVICE INST. NO. ADTR-55004 Recorder CH 1 (Red Channel) COMMENTS:
INDICATION UNITS OF OHMS EXPECTED LO LIMIT HI LIMIT AS FOUND 88.899 -18.90 -19.80 -18.00 96.307 15.00 14.10 15.90 103.910 50.00 49.10 50.90 111.468 85.00 84.10 85.90 118.748 118.90 118.00 119.80 111.468 85.00 84.10 85.90 103.910 50.00 49.10 50.90 96.307 15.00 14.10 15.90 88.899 -18.90 -19.80 -18.00 Printed March 17, 2006 at 8:20
I-J - F C C Approved By T. W. Cook 1- - I - Vogtle Electric Generating Plant A I Procedure Number
-I. 24688-C Rev 16 Date Approved METEOROLOGICAL STATION 10M AMBIENT AND 10-60M DELTA TEMPERATURE CHANNEL CALIBRATION Page Number 09/27/05 1 58 of 71 SHEET 2 OF 2
- AteoolSiasl M tratio Meteorological Station
Title:
Meteorological Station IOM Ambient Temperature NOTES:
INST. NO. T6172 Computer Point COMMENTS:
INPUT UNITS OF OHMS EXPECTED LO LIMIT HI LIMIT - AS FOUND 88.899 -18.900 -19.615 -18.185 96.307 15.000 14.285 15.715 103.910 50.000 49.285 50.715 111.468 85.000 84.285 85.715 118.748 118.900 118.185 119.615 111.468 85.000 84.285 85.715 103.910 50.000 49.285 50.715 96.307 15.000 14.285 15.715 88.899 -18.900 -19.615 -18.185 I PERFORMED BY: DATE:
Printed March 17, 2006 at 8:20
Approved By r- C IProcedure Number Rev T. W. Cook Vogtle Electric Generating Plant A {24688-C 16 Date Approved METEOROLOGICAL STATION 10M AMBIENT AND 10-60M DELTA TEMPERATURE CHANNEL CALIBRATION Page Number 09/27/05 59 of 71 SHEET 1 OF 2 DATA SHEI-T 2 Meteorological Station
Title:
Meteorological Station 10-60M Delta Temperature NOTES: 1OM ambient temperature RTD simulator adjusted for 103.910 ohms.
DEVICE I INST. NO. ADTR-55004 Recorder CH 2 (Blue Channel) COMMENTS:
INDICATION UNITS OF OHMS EXPECTED LO LIMIT HI LIMIT AS FOUND:
101.886 -9.400 -9.670 -9.130 103.383 -2.500 -2.770 -2.230 105.009 5.000 4.730 5.270 106.632 12.500 12.230 12.770 108.124 19.400 19.130 19.670 106.632 12.500 12.230 12.770 105.009 5.000 4.730 5.270 103.383 -2.500 -2.770 -2.230 101.886 -9.400 -9.670 -9.130 Printed March 17, 2006 at 8:20
Approved By C C C Procedure Number Rev T. W. Cook Vogtle Electric Generating Plant 268C 1 Date Approved METEOROLOGICAL STATION 10M AMBIENT AND 10-60M DELTA TEMPERATURE CHANNEL CALIBRATION Page Number 09/27/05 60 of 71 SHEET 2 OF 2 uA I AM)rlc I Z Meteorological Station
Title:
Meteorological Station 10-60M Delta Temperature NOTES: 1OM ambient temperature RTD simulator adjusted for 103.910 ohms.
INST. NO. T6174 Computer Point COMMENTS:
INPUT UNITS OF OHMS EXPECTED l.LO LIMIT - HI LIMIT AS FOUND 103.318 -2.800 -2.973 -2.627 103.926 0.000 -0.173 0.173 105.009 5.000 4.827 5.173 106.632 12.500 12.327 12.673 108.124 19.400 19.227 19.573 106.632 12.500 12.327 12.673 105.009 5.000 4.827 5.173 103.926 0.000 -0.173 0.173 103.318 -2.800 -2.973 -2.627 PERFORMED BY: DATE:
Printed March 17, 2006 at 8:20
WC C r Approved By - Procedure Nurnber Rev T. W. Cook Vogtle Electric Generating Plant A 24688-C 16 Date Approved METEOROLOGICAL STATION 10M AMBIENT AND 10-60M DELTA TEMPERATURE CHANNEL CALIBRATION Page Number 09/27/05 61 of 71 SHEET 1 OF 1 DATIA onhc_
Instr. No. ATY-55004A Location Meteorological Station Serial No. 338 Ambient Temp.
Description Platinum RTD Translator Card Manufacturer Climatronics Model No. 101400-G14 NOTES: Signal conditioner serial number 338 is matched to RTD serial number 4018607.
I
.I -INPUT - EXPECTED, LO LIMIT ] HI LIMIT I AS FOUND T, AS LEFT COMMENTS:
OHMS V DC V DC VDC VOC V DC 0 88.658 0.000 -0.014 0.014 25 96.307 1.250 1.236 1.264 50 103.910 2.500 2.486 2.514 75 111.468 3.750 3.736 3.764 100 118.983 5.000 4.986 5.014 75 111.468 3.750 3.736 3.764 50 103.910 2.500 2.486 2.514 25 96.307 1.250 1.236 1.264 0 88.658 0.000 -0.014 0.014 I PERFORMED BY: DATE:
Printed March 17, 2006 at 8:20
Vogtle Electric Generating Plant A Procedure Number 1 24688-C Rev 16 1 LTION 10M AMBIENT AND 10-60M DELTA TEMPERATURE CHANNEL CALIBRATION Page Number I 62 of 71 SHEET I OF 1 DuM TSn'mOcE '4 Instr. No. ATDR-55004 CH 1 (Red Channel) Location Meteorological Station Serial No.
1OM Ambient Temperature Description Videographic Recorder Manufacturer Yokogawa Model No. DX1 04-3-2/Sl 20 NOTES: N/A INPUT - - EXPECTED ---O-LIMIT-- ---Hi LIMIT- -AS FOUND AS LEFT COMMENTS:
OHMS : - ...OF 0F OF. '-OF 88.899 -18.90 -19.80 -18.00 96.307 15.00 14.10 15.90 103.910 50.00 49.10 50.90 111.468 85.00 84.10 85.90 118.748 118.90 118.00 119.80 111.468 85.00 84.10 85.90 103.910 50.00 49.10 50.90 96.307 15.00 14.10 15.90 88.899 -18.90 -19.80 -18.00 l PERFORMED BY: DATE:
Printed March 17, 2006 at 8:20
Approved By Procedure Number Rev T. W. Cook Vogtle Electric Generating Plant A - 24688-C 16 Date Approved METEOROLOGICAL STATION 10M AMBIENT AND 10-60M DELTA TEMPERATURE CHANNEL CALIBRATION Page Number 09/27/05 63 of 71 SHEET 1 OF 1 DATMA SnHET ;
Instr. No. T6172 Location N/A Serial No. N/A 1OM Ambient Temperature Description Computer Point Manufacturer N/A Model No. N/A NOTES: N/A INPUT EXPECTED LO LIMIT Hi LIMIT AS FOUND AS LEFT COMMENTS:
OHM O F - F OF,- OF 88.899 -18.900 -19.615 -18.185 96.307 15.000 14.285 15.715 103.910 50.000 49.285 50.715 111.468 85.000 84.285 85.715 118.748 118.900 118.185 119.615 111.468 85.000 84.285 85.715 103.910 50.000 49.285 50.715 96.307 15.000 14.285 15.715 88.899 -18.900 -19.615 -18.185 l PERFORMED BY: DATE:
Prnted March 17, 2006 at 8:20
Approved By & I Procedure Number Rev T. W. Cook Vogtle Electric Generating Plant a~I24688-C 16 Date Approved METEOROLOGICAL STATION 10M AMBIENT AND 10-60M DELTA TEMPERATURE CHANNEL CALIBRATION Page Number 09/27/05 64 of 71 SHEET 1 OF 1 UATA SH-EET 5 Instr. No. ATDY-55004A Location Meteorological Station Serial No. 341 Description Delta Temp. Translator Card Manufacturer Climatronics Model No. 101400-1-G12 NOTES: Translator card Serial No.341 is matched with RTD Serial No. 4018607.
Ambient temperature RTD simulator adjusted for 103.910 ohms (50.0 'F).
- .INPUT
........ L - .L
-_ _ EXPECTED LO LIMIT HI LIMIT AS FOUND --AS LEFT I COMMENTS:
I - - , -- . .. . . :. .I . , : - , l. - .. I . - .. ......
.. :~ . . e- .11~..... - - . .........
._, -=.
I ........
b....
OHMS V DC V DC V DC I V DC ; VDC 0 101.756 0.000 -0.022 0.022 25 103.383 1.250 1.228 1.272 50 105.009 2.500 2.478 2.522 75 106.632 3.750 3.728 3.772 100 108.253 5.000 4.978 5.022 75 106.632 3.750 3.728 3.772 50 105.009 2.500 2.478 2.522 25 103.383 1.250 1.228 1.272 7-0o 100 101.7596 0.000 -0.022 10.022 I PERFORMED BY: DATE:
Printed March 17, 2006 at 8:20
r r Approved By T.
T. W..ooo CooktleElectric Generating Plant A , Procedure Number 48-268-C Rev 16 Date Approved METEOROLOGICAL STATION 10M AMBIENT AND 1060M DELTA TEMPERATURE CHANNEL CALIBRATION Page Number 09/27/05 65 of 71 SHEET 1 OF 1 DAIA SHEET 7 Instr. No. ATDR-55004 CH 2 (Blue Channel) Location Meteorological Station Serial No.60-10M Delta Temperature Description Videographic Recorder Manufacturer Yokogawa Model No. DX1 04-3-2/Sl 20 NOTES: 1OM ambient temperature RTD simulator adjusted for 103.910 ohms (50.0 OF).
INPUT - EXPECTED LO LIMIT I Hi LIMIT I AS FOUND AS LEFT- I COMMENTS:
OHMS OF OF OF i O--__F 101.886 -9.400 -9.670 -9.130 103.383 -2.500 -2.770 -2.230 105.009 5.000 4.730 5.270 106.632 12.500 12.230 12.770 108.124 19.400 19.130 19.670 106.632 12.500 12.230 12.770 105.009 5.000 4.730 5.270 103.383 -2.500 -2.770 -2.230 101.886 -9.400 -9.670 -9.130 I PERFORMED BY: DATE:
Printed March 17, 2006 at 8:20
C C C-Vogtle Electric Generating Plant A Procedure Number 124688-C Rev 16
, STATION 10M AMBIENT AND 10-60M DELTA TEMPERATURE CHANNEL CALIBRATION Page Number I 66of71 SHEET 1 OF 1
% ArA CUtL== 0 Vjp I M
" J t m...L.oI w Instr. No. T6174 Location N/A Serial No. N/A Delta Temperature Description Computer Point Manufacturer N/A Model No. N/A NOTES: 1OM ambient temperature RTD simulator adjusted for 103.910 ohms (50.0 0F).
INPUT EXPECTED I LO LIMIT 0F I Hi LIMIT :IAS FOUND l -AS LEFT - I COMMENTS:
OHM OF OF OF --OF 103.318 -2.800 -2.973 -2.627 103.926 0.000 -0.173 0.173 105.009 5.000 4.827 5.173 106.632 12.500 12.327 12.673 108.124 19.400 19.227 19.573 106.632 12.500 12.327 12.673 105.009 5.000 4.827 5.173 103.926 0.000 -0.173 0.173 103.318 -2.800 -2.973 -2.627 I PERFORMED BY: DATE:
Printed March 17, 2006 at 8:20
/I-Approved By I .
C r I . I Procedure Number Rev T. W. Cook T. WCoo Vogtle Electric Generating Plant - 24688AC Date Approved METEOROLOGICAL STATION IOM AMBIENT AND 10-60M DELTA TEMPERATURE CHANNEL CALIBRATION 2468-C 16 Page Number 09/27/05 67 of 71 SHEET 1 OF 1 DATA SHniET Instr. No. ATE-55004A Location Meteorological Tower 1OM Serial No. 4018608 Description Ambient Temp. Platinum RTD Manufacturer Climatronics Model No. 100826 NOTES: Signal conditioner serial number 338 is matched to RTD serial number 4018608.
INPUT EXPECTED LO LIMIT HI LIMIT AS LEFT-32 32 31.1 32.9 100 100 99.1 100.9 COMMENTS:
PERFORMED BY: DATE:
Printed March 17, 2006 at 8:20
r 7 Approved By T. W. Cook Date Approved 1 - Vogtle Electric Generating Plant A METEOROLOGICAL STATION 10M AMBIENT AND 10-60M DELTA TEMPERATURE CHANNEL CALIBRATION l Procedure ;un'iber
- 24688-C Rev 16 I Page Number 09/27/05 SDN I68 of 71 SHEET 1 OF 1 ntArA eOUTCr -in Instr. No. ATDE-55005B Location Meteorological Tower 60M Serial No. 4018607 Description Delta Temp. Platinum RTD Manufacturer Climatronics Model No. 100826 NOTES: Translator card Serial No.341 is matched with RTD Serial No. 4018607.
INPUT EXPECTED LO LIMIT HI LIMIT AS LEFT OF- OF OF- F:-----°-- 0 V 32 0 -0.27 0.27 100 0 -0.27 0.27 COMMENTS:
l PERFORMED BY: DATE:
Printed March 17, 2006 at 8:20
C la Approved By T. W. Cook I Vogtle Electric Generating Plant A IF2488-C u26 NMber Rev 16 Date Approved METEOROLOGICAL STATION IOM AMBIENT AND 10-60M DELTA TEMPERATURE CHANNEL CALIBRATION Page Number 09/27/05 I 1 69 of 71 M&TE SHEET
_ TEST EQUIPMENT USED 1.D. NUMBER MODEL NO. ICALIBRATION DUE DATE DATA SHEETS IMPACTED 4 4 4 4 t 4
-4 4 4 t 4 4 4 4 I-4 1 4 4 4 4 4 1- 4 4 4- 4 4 4- 4 1 4- 4 4 4- 4 COMMENTS:
COMPLETED BY: IDATE:
Printed March 17, 2006 at 8:20
Approved By Procedure Number Rev T. W. Cook Vogtle Electric Generating Plant 24688-C 16 Date Approved METEOROLOGICAL STATION 1DM AMBIENT AND 10-60M DELTA Page Number 09/27/05 TEMPERATURE CHANNEL CALIBRATION 70 of 71 Sheet 1 of 1 CALCULATION SHEET Show all calculations performed during course of this procedure in the space below.
Completed by: Date:
Printed March 17, 2C06 at 8:20
Approved By Procedure Number Rev T.pdCyook W. l i xVogtle Electric Generating Plant 24688-C 16 Date Approved METEOROLOGICAL STATION 1DM AMBIENT AND 10-60M DELTA Page Number 09/27/05 TEMPERATURE CHANNEL CALIBRATION 71 of 71 Sheet 1 of 1 COMPLETION SHEET DEFICIENCIES OCCURRED AND ACTIONS TAKEN PERSONNEL PERFORMING WORK (Print Name) INITIAL TOTAL NUMBER OF PAGES USED (Signatures, Initials, Data etc.) 111 APPROVED BY: DATE: