Approved By Procedure Number Rev Shan Sundnram Vogde Electric Generating Plant g

32432-C 3

Date Apprved DETERMINATION OF SETTLEABLE SOLIDS IN SEWVAGEPage Numter 08/06/2004 1 of 2 DETERMINATION OF SETTLEABLE SOLIDS IN SEWAGE PROCEDURE USAGE REQUIREMENTS-SECTIONS Continuous Use: Procedure must be open and readily available at the work NONE location. Follow procedure step by step unless otherwise directed.

Reference Use:

Procedure or applicable section(s) available at the work ALL location for ready reference by person performing steps.

Information Use: Available on plant site for reference as needed.

NONE

!11 i

.i II i,

1I Print1-I M.-I If, 7nlnr tf i0 O

Approved By 4Procedure Number Rev SAnpSundarai i

vogtle Electric Generating Plant is I 32432-C 3

Date Approved DETERMINATION OF SETTLEABLE SOLIDS IN SEWVAGE Page Number 08/06/2004 I2 of 2 REFERENCE USE 1.0 PURPOSE This procedure provides instructions for the determination of settleable solids in sewage.

2.0 PRECAUTIONS 2.1 Mix the sample thoroughly prior to performing test.

2.2 Keep in mind what your sample consists of and take all appropriate precautions to prevent personnel contamination.

3.0 MATERIALS 3.1 Imhoff cone or equivalent 4.0 TEST STAND QUALITYCONTROL 4.1 Calibrations arc not applicable to this procedure.

4.2 Calibration checks are not applicable to this procedure.

5.0 INSTRUCTIONS 5.1 Pour 1000 ml of sample from the aeration chamber of the sewage treatment plant into an Imrhoff cone or equivalent.

5.2 Allow to settle for approximately 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />.

5.3 Observe the volume of sludge. Obtain the percentage of settleable solids by dividing the sludge volume by 10.

5.4 Record results on the appropriate data sheet.

6.0 REFERENCES

6.1 VEGP Procedure 35585-C "Operation Of The Sewage Treatment Plant" END OF PROCEDURE TEXT Pnntrwl M-rl It, ')1{>