SOUTHERN CALIFORNIA Brian Katz EDISOVN Vice President An EDISON INTERNATIONALS Company February 7, 2006 U. S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555

Subject:

Docket No. 50-361 Special Report: Inservice Inspection of Steam Generator Tubes, Cycle 14 San Onofre Nuclear Generating Station, Unit 2

Reference:

Steam Generator Program Guidelines, Nuclear Energy Institute Document Number NEI 97-06, Revision 2

Dear Sir or Madam:

On January 24, 2006, Southern California Edison (SCE) completed the inservice inspection of steam generator tubes at San Onofre Nuclear Generating Station Unit 2. The attached report is submitted in accordance with Technical Specification (TS) 5.7.2.c reporting requirements:

Report the number of tubes plugged and tubes sleeved in each steam generator within 15 days of completing the inspection; Report the complete results of steam generator tube inspections within 12 months of inspection completion; Report the results of steam generator tube inspections which fall into Category C-3 prior to resumption of plant operation.

The attachment to this letter, uSpecial Report-4nservice Inspection of Steam Generator Tubes," which was prepared in accordance with the referenced industry guidance, satisfies these reporting requirements. The report contains no new commitments.

If you require any additional information, please advise.

Sincerely, Attachments cc:

B. S. Mallett, NRC Regional Administrator, Region IV N. Kalyanam, NRC Project Manager, San Onofre Units 2, and 3 C. C. Osterholtz, NRC Senior Resident Inspector, San Onofre Units 2 & 3 Institute of Nuclear Power Operations (INF'O)

P.O. Box 128 San Clemente, CA 92674-0128 m T)4I 949-368-9275 Fax 949-368-9881

Inservice Inspection of Steam Generator Tubes Special Report Attachment Page 1 of 26 SPECIAL REPORT - INSERVICE INSPECTION OF STEAM GENERATOR TUBES Regulatory Reporting Requirements Reporting Requirement 5.7.2.c of Appendix A, Technical Specification to Facility Operating License NPF-10 requires the number of tubes plugged and tubes sleeved in each steam generator to be reported to the Nuclear Regulatory Commission within 15 days following completion of the inspection.

Reporting Requirement 5.7.2.c of Appendix A, Technical Specification to Facility Operating License NPF-1 0 requires the results of steam generator tube inspections which fall into Category C-3 to be reported to the Nuclear Regulatory Commission prior to resumption of plant operation.

Reporting Requirement 5.7.2.c of Appendix A, Technical Specification to Facility Operating License NPF-1 0 requires the complete results of steam generator tube inspections to be reported to the Nuclear Regulatory Commission within 12 months following completion of the inspection.

Inspection Scope Tables 1 A and 1 B summarize the inspection scope. Also, when indications by the bobbin probe were non-quantifiable or distorted, the inspection scope included inspection with the Plus Point Probe; Table 2A provides the list of Nondestructive Examination (NDE) techniques utilized for each degradation mechanism found as a result of the inspection. Other mechanisms that were considered in the inspection planning are included in Table 2B.

Inspection Scope Expansion There were no significant inspection scope expansions in response to inspection results.

Results of the Inservice Inspection of Tubes This report satisfies the listed regulatory reporting requirements.

The contents of this report were prepared using the guidance contained in NEI 97-06, Rev. 2, "Steam Generator Program Guidelines." The NEI guidance is an initiative to unify the industry approach towards steam generator issues and strengthen, where necessary, the steam generator program.

Table 3 summarizes the number of tubes repaired and active degradation mechanisms found. Each tube is only counted once in this listing, although it may also have an eddy current indication of a type below the point in the listing where it appears. The Appendices provide the complete results of the steam generator tubing inservice inspection.

The inside diameter of 98 inservice sleeves was found to be reduced. In response to this:

  • These 98 tubes have been removed from service by plugging both ends of the tubes.
  • The dominant number of the sleeves with reduced diameters that have been experienced at San Onofre Unit 2 have occurred in groups of sleeves that were installed at particular outages (Cycle 12 and 13). Table 5 shows the relationship between the diameter reduction and the outage when the sleeves were installed.
  • SCE has removed all sleeves from service that were installed during the Cycle 12 and 13 outages by plugging the respective tubes.

Inservice Inspection of Steam Generator Tubes Special Report Attachment Page 2 of 26 SCE Nuclear Fuel Management has implemented a conservative assumption that each remaining inservice sleeve may pose the potential for reactor coolant flow blockage, similar to that of a tube that is removed from service by plugging.

Condition Monitoring Condition Monitoring demonstrated that performance criteria in the NEI guidance (structural integrity and accident-induced leakage) were met during operation prior to this inspection.

In situ pressure testing was not needed for any sized eddy current indications. All sized indications were below screening criteria of the Electric Power Research Institute (EPRI) In Situ Pressure Testing Guidelines. Tables 8 and 9 list the tubes and sizing information for screening for in situ testing.

The remainder of this section will describe Condition Monitoring for 18 tubes. These tubes had sleeves with reduced diameters, that would not allow planned (rotating plus point probe) inspection of bobbin probe indications and dents at tube supports.

SCE had a technical basis to complete Condition Monitoring on approximately half of these 18 tubes, without in situ pressure testing. Use of all technical resources was consistent with maintaining personnel radiation exposure As Low As Reasonably Achievable (ALARA). A description of that basis follows.

The technical basis that SCE normally uses for bobbin probe detection of Primary Water Stress Corrosion Cracking (PWSCC) at dents < 2 volts is an EPRI-qualified technique, named Examination Technique Specification Sheet (ETSS) 96012.1. Westinghouse made this ETSS data set (consisting of tubing with PWSCC crack(s) at a dented tube support). These tube supports were the "drilled plate" type. Thus, SCE normally performs rotating plus point probe exam of all dents 2 2 volts.

SCE had Westinghouse make a similar data set of assemblies (consisting of tubing with PWSCC crack(s) at a dented tube support). San Onofre Units 2 and 3 have "lattice bar" supports, rather than "drilled plate" supports. The SCE data set had tube supports of the "lattice bar" type to demonstrate detection capabilities at this different tube support type. The SCE data set was extensively tested, resulting in a Westinghouse-developed technique for bobbin probe detection of PWSCC at dents

  • 5 volts (at lattice bar tube supports). This technique met qualification acceptance criteria in Appendix H of the EPRI Pressurized Water Reactor (PWR) Steam Generator Examination Guidelines, and was reviewed/concurred with by an appropriate Qualified Data Analyst (QDA) in accordance with Section 6 of the EPRI PWR SG Examination Guidelines. SCE has previously used this qualified technique only as a reference of the conservatism of SCE use of EPRI ETSS 96012.1.

Condition Monitoring for 8 tubes was successfully completed by a three-step process. The technical basis was the Westinghouse-developed technique for lattice bar supports. As a conservatism, the full 5 volt dent size of the qualification was not considered; only dents < 4 volts were considered in this process.

Step 1 -

Review dent history. Acceptance criteria: Dent has a history of rotating probe exam (several inspections).

Step 2 -

Review dent signal. Acceptance criteria: No distortion Step 3 -

Document successful completion of Condition Monitoring for the tube Condition Monitoring for the remaining 10 tubes was successfully completed (i.e., no leakage) by In Situ Pressure and Leak Testing. Table 4 is a list of these 10 tubes with related information. The full

Inservice Inspection of Steam Generator Tubes Special Report Attachment Page 3 of 26 length of these tubes was tested, including the sleeve with reduced diameter. Thus, the testing also demonstrated the structural integrity and leakage integrity of the 10 reduced diameter sleeves.

No tubes were removed (pulled) for destructive testing during this outage.

Repair of Tubes Table 6 provides an itemized listing of the tubes plugged in Steam Generator E-088 along with the corresponding Table 3 category specifying the indication orientation/location.

Table 7 provides an itemized listing of tubes plugged in Steam Generator E-089 along with the corresponding Table 3 category specifying the indication orientation/location.

Repair Methods, Number of Tubes Repaired and Effective Plugging Percentage All tube plugging was performed using the design, materials, and installation methods of AREVA. A "roll" method was used for all tube plugs. 76 tubes were "stabilized" in the vicinity of the top of the tubesheet using the design, materials, and installation methods of AREVA. Sleeving was not used for tube repair for the Cycle 14 outage.

Three hundred eighteen (318) tubes were plugged in Steam Generator E-088 during the Cycle 14 refueling outage. A total of one thousand two hundred fifty-seven (1257) tubes have been plugged.

One hundred fifty-nine (159) sleeved tubes are in service. The design number of tubes is 9350 tubes and the sleeve-to-plug equivalency ratio is thirty-eight sleeves per plug. The effective plugging percentage for E-088 is 13.5%.

One hundred sixty-six (166) tubes were plugged in Steam Generator E-089 during the Cycle 14 refueling outage. A total of one thousand one hundred twenty-six (1126) tubes have been plugged.

Ninety-seven (97) sleeved tubes are in service. The design number of tubes is 9350 tubes and the sleeve-to-plug equivalency ratio is thirty-eight sleeves per plug. The effective plugging percentage for E-089 is 12.1%.

Causes and Corrective Actions The degradation detected during this inspection remained within the Technical Specification Category C-3. There is no significant update from previous reports of causes and corrective actions for Category C-3 results. Thus, corrective actions remain unchanged from earlier inspections. As previously reported, these corrective actions are:

Actions have been taken to improve the secondary side chemistry environment for steam generator tubing in both Unit 2 steam generators. These actions have been reviewed by a panel of industry experts for application at San Onofre. The expert panel concurs with these measures. The actions include:

1. Chemical cleaning of the entire tube bundle (full bundle) performed during the Cycle 9 refueling outage in December 1996.
2. Addition of an inhibitor (titanium dioxide) for IGA/SCC immediately after the chemical cleaning for maximum crevice penetration potential. This is ongoing.
3. Use of Ethanolamine (ETA) for pH control of the secondary fluids. This is ongoing.

Inservice Inspection of Steam Generator Tubes Special Report Attachment Page 4 of 26

4. Boric acid addition in the secondary side to help reduce denting of the tube supports and stress corrosion cracking of tubing. This is ongoing.

In addition, SCE reduced the reactor coolant temperature at the steam generator inlet (T-hot) by about 11 OF. SCE expects this will reduce stress corrosion cracking of the tubing initiating from the inside diameter of the tubing. The first phase of this change, a reduction of about 40F, was completed in January 1998. The final phase of this change, a reduction of an additional 70F, was completed in February 1999.

Inservice Inspection of Steam Generator Tubes Attachment Description of Tables and Appendices Special Report Page 5 of 26 Table 1 A -

Steam Generator E-088 -- Summary of the Inspection Scope for the Unit 2 Cycle 14 (U2C1 4) Refueling Outage Table 1 B -

Steam Generator E-089 -- Summary of the Inspection Scope for the Unit 2 Cycle 14 (U2C14) Refueling Outage Table 2A -

List of Nondestructive Examination (NDE) Techniques Utilized for Each Degradation Mechanism Found During the U2C14 Refueling Outage Table 2B -

List of Nondestructive Examination (NDE) Techniques Utilized for Other Degradation Mechanisms; Considered During the U2C14 Refueling Outage Table 3 -

Number of Tubes Repaired and Active Degradation Mechanisms Found During the U2C14 Refueling Outage Table 4 -

Summary of Results of In Situ Pressure and Leak Testing for the U2C14 Refueling Outage Table 5 -

U2C1 0 through U2C1 4 Sleeving Summary Table 6 -

U2C1 4 Refueling Outage Tubes Plugged, Steam Generator E-088 Table 7 -

U2C14 Refueling Outage Tubes Plugged, Steam Generator E-089 Table 8 -

Measured Sizes of Service-induced Indications Steam Generator E-088-Table 9 -

Measured Sizes of Service-Induced Indications Steam Generator E-089 Appendix 1 -

Steam Generator Reference Information Appendix 2 -

Legend for Appendices 3 through 6 Appendix 3 -

Tube Inspection Summary, Steam Generator E-088 Appendix 4 -

Tube Inspection Summary, Steam Generator E-089 Appendix 5 -

Sleeve Inspection Summary, Steam Generator E-088 Appendix 6 -

Sleeve Inspection Summary, Steam Generator E-089

Inservice Inspection of Steam Generator Tubes Attachment Special Report Page 6 of 26 TABLE 1A - Steam Generator E-088 - Summary of the Inspection Scope for the Unit 2 Cycle 14 (U2C14) Refueling Outage Tubes/Percent Full length of tube with the bobbin probe (excluding sleeved 8411/100%

regions and U-bends for Rows 1-3)

Hot leg expansion transition of unsleeved tubes at the top-of-tubesheet with the Plus Point Probe to an extent of 4 8066/100%

inches above to 13 inches below the top-of-tubesheet Cold leg expansion transition at the top-of-tubesheet with the Plus Point Probe to an extent of 2 inches above to 13 2601/30%

inches below the top-of-tubesheet U-bend regions of Rows 1, 2, and 3 with both mid and high 179/100%

frequency Plus Point Probes U-bend regions of Row 4 at the U-bend with the mid 57/100%

frequency Plus Point Probe U-bend regions of Rows 5 through 1 0 at the U-bend with 74/20%

the mid frequency Plus Point Probe Plus Point Probe examinations of hot leg scallop bar supports with the above adjacent hot leg square bend and 81/22%

the below one support elevation of tubing freespan Plus Point Probe examinations of tube support intersections 2701/99° Not 1 with dents greater than, or equal to, 2 volts 2

(Note )

Plus Point Probe examination of dings greater than, or 395/100%

equal to, 4 volts Plus Point Probe examination of all tube support intersections with quantified wear indications by the bobbin 360/100%

probe Full length of sleeves with the Plus Point Probe 345/100%

Tube below sleeve from bottom of sleeve to -1.25 inches 345/100%

with the Plus Point Probe Note 1 - See Condition Monitoring Section for explanation of why this was not 100%

Inservice Inspection of Steam Generator Tubes Attachment Special Report Page 7 of 26 TABLE 1 B - Steam Generator E-089 - Summary of the Inspection Scope for the Unit 2 Cycle 14 (U2C14) Refueling Outage Tubes/Percent Full length of tube with the bobbin probe (excluding sleeved 8390/100%

regions and U-bends for Rows 1-3)

Hot leg expansion transition of unsleaved tubes at the top-of-tubesheet with the Plus Point Probe to an extent of 4 8201/100%

inches above to 13 inches below the top-of-tubesheet Cold leg expansion transition at the top-of-tubesheet with the Plus Point Probe to an extent of 2 inches above to 13 2567/30%

inches below the top-of-tubesheet U-bend regions of Rows 1, 2, and 3 with both mid and high 172/100%

frequency Plus Point Probes U-bend regions of Row 4 at the U-bend with the mid 60/100%

frequency Plus Point Probe U-bend regions of Rows 5 through 10 at the U-bend with 74/20%

the mid frequency Plus Point Probe 7

Plus Point Probe examinations of hot leg scallop bar supports with the above adjacent hot leg square bend and 74/20%

the below one support elevation of tubing freespan Plus Point Probe examinations of tube support intersections 1852/99% (Note 1) with dents greater than, or equal to, 2 volts Plus Point Probe examination of dings greater than, or 370/100%

equal to, 4 volts Plus Point Probe examination of all tube support intersections with quantified wear indications by the bobbin 445/100%

probe Full length of sleeves with the Plus Point Probe 189/100%

Tube below sleeve from bottom of sleeve to -1.25 inches 189/100%

with the Plus Point Probe Note 1 - See Condition Monitoring Section for explanation of why this was not 100%

Inservice Inspection of Steam Generator Tubes Attachment Special Report Page 8 of 26 TABLE 2A - List of Nondestructive Examination (NDE) Techniques Utilized for Each Degradation Mechanism Found During the U2C14 Refueling Outage Indication Orientation/Locationl Pr be Type for Detection Characterization Axially oriented ID (initiated on the inside-diameter of Bobbin Plus Point the tubing wall) indications at tube support locations Plus Point Plus Point (Note_1)

Axially oriented OD (initiated on the outside-diameter Bobbin Plus Point of the tubing wall) indications at tube support locations Plus Point Plus Point (Note 1)

Axially oriented OD indications not associated with a Bobbin Plus Point tube support (freespan)

Circumferentially oriented ID indications near the expansion transition at the top of the hot leg tubesheet Plus Point Plus Point Circumferentially oriented OD indications near the expansion transition at the top of the hot leg tubesheet Plus Point Plus Point Axially oriented indications in the sludge pile region Plus Point Plus Point near the top of the hot leg tubesheet Axially oriented ID indications near or below the expansion transition at the top of the hot leg tubesheet Plus Point Plus Point Circumferentially oriented ID indications below the expansion transition at the top of the hot leg tubesheet Plus Point Plus Point Indications of wear at tube support locations Bobbin Plus Point Miscellaneous preventive plugging Bobbin or Plus Point Note 1: Plus Point technique is used at dents with greater than, or equal to, two volts.

Inservice Inspection of Steam Generator Tubes Attachment Special Report Page 9 of 26 TABLE 2B - List of Nondestructive Examination (NDE) Techniques Utilized for Other Degradation Mechanisms Considered During the U2C14 Refueling Outage Indication Orientation/Location Detection Characterization Circumferentially oriented ID and Circumferentially oriented Plus Point Plus Point OD at dented tube supports_(dents 22 volts)

Axially oriented ID and Circumferentially oriented ID in Plus Point Plus Point Low-Row U-bends Circumferentially oriented ID at the Flanks of Tubing Bends Plus Point Plus Point and Axially oriented ID in similar Tubing Bends Axially oriented OD in Low-Row U-Bends Plus Point Plus Point Circumferentially oriented OD associated with Fort Calhoun tube support configuration (SONGS configuration is Plus Point Plus Point different)

Axially oriented OD at dings in tubing freespan (dings <4 Bobbin Plus Point volts)

Axially oriented OD and Circumferentially oriented OD at Plus Point Plus Point dings in tubing freespan (dings 24 volts)

Axially oriented ID and Circumferentially oriented ID at the Plus Point Plus Point -

top of the cold leg tubesheet Axially oriented OD at the top of the cold leg tubesheet Plus Point Plus Point Axially oriented ID and Circumferentially oriented ID in Plus Point Plus Point explosively expanded tubing within the cold leg tubesheet OD pitting in or above the sludge pile Bobbin Plus Point Tube Plug Degradation Visual Visual Impingement in tubing freespan Bobbin Plus Point Cold Leg Thinning at tube supports Bobbin Plus Point Volumetric indications Bobbin or Plus Plus Point Point

Inservice Inspection of Steam Generator Tubes Attachment Special Report Page 10 of 26 TABLE 3 - Number of Tubes Repaired and Active Degradation Mechanisms Found During the! U2C14 Refueling Outage Steam Generator E-088 E-089 Indication Orientation/Location 1

Tubes with axially oriented ID (initiated on the inside-diameter of the tubing wall) indications at tube support locations 4

2 (ID Axial @ Support) 2 Tubes with axially oriented OD (initiated on the outside-diameter of the tubing wall) indications at tube support locations 32 20 (OD Axial @ Support) 3 Tubes with axially oriented OD indications not associated with a 3

3 tube support (freespan) (OD Axial @ Freespan) 4 Tubes with circumferentially oriented ID indications near the expansion transition at the top of the hot leg tubesheet 36 6

(ID Circ @ TSH) 5 Tubes with circumferentially oriented OD indications near the expansion transition at the top of the hot leg tubesheet 13 15 (OD Circ @ TSH) 6 Tubes with axially oriented OD indications in the sludge pile region near the top of the hot leg tubesheet 7

7 (OD Axial @ Sludge Pile TSH) 7 Tubes with axially oriented ID indications below the inlet top-of-20 11 tubesheet (ID Axial below TSH) 8 Tubes with circumferentially oriented ID indications below the 8

3 inlet top-of-tubesheet (ID Circ belowN TSH) 9 Tubes with indications of wear at tube support locations 22 9

(Wear @ Support) 10 Sleeved Tubes with obstructions in the sleeved area 43 26 (OBS @ Sleeve) 11 Sleeved Tubes with indications of partial obstruction in the 19 9

sleeved area (PCS @ Sleeve) 12 Sleeved Tubes Plugged as a preventive measure 111 55 Total 318 166

Inservice Inspection of Steam Generator Tubes Attachment Special Report Page 11 of 26 TABLE 4 - Summary of Results of In Situ Pressure and Leak Testing for the U2C14 Refueling Outage STEAM GENERATOR E-088 TUBE INFORMATION BOBBIN DATA IN SITU TEST RESULTS REGION ROW COL LOCATION VOLTS PROBE SIZE GPM @ GPM @ PRESSURE NOPD MSLB.

3xNOPD DNI @ 06H+0.05 4.36 600UL EGGCRATE 41 103 DNT @ 06H -0.31 8.82 600UL 0

0 5000 DNT @ 06H+0.58 4.44 600UL EGGCRATE 46 72 DNT @ 05H +0.44 6.12 600UL 0

0 5000

__DNT

@ 06H+0.66 6.00 600UL EGGCRATE 59 65 DNT @ 07H+0.05 3.13 600UL 0

0 5000 EGGCRATE 60 66 ONT @ 07H +0.24 2.32 600UL 0

0 5000 EGGCRATE 65 149 DNT @ 06H +0.30 5.69 600UL 0

0 5000 STEAM GENERATOR E-089 TUBE INFORMATION BOBBIN DATA IN SITU TEST RESULTS REGION ROW COL LOCATION VOLTS PROBE SIZE GPM 0 GPM 0 PRESSURE NOPD MSLB 3xNOPD EGGCRATE 24 112 DNT@06H +0.31 16.21 600UL 0

0 5000 DNT@04H +0.38 7.32 600UL EGGCRATE 31 65 DNI@05H+0.86 0.89 600UL 0

0 5000 EGCAE 3

5 DNT@05H-0.01 2.65 600UL 0

050 DNT@06H +0.24 2.43 600UL EGGCRATE 38 116 DNT@07H-0.49 2.49 600UL 0

0 5000 DNT@06H-0.23 6.22 600UL EGGCRATE 48 74 DNT@03H-0.68 2.65 600UL 0

0 5000 DNT@06H+0.32 2.61 600UL EGGCRATE 55 69 DNT@06H+0.52 3.08 600UL 0

0 5000 NOTES:

GPM = Gallons per Minute NOPD = Normal Operation Pressure Differential MSLB = Main Steam Line Break Pressure Differential DNT = Dented intersection 2 2 Volts DNI = Dent with Indication

Inservice Inspection of Steam Generator Tubes Attachment Special Report Page 12 of 26 TABLE 5 - U2C10 through U2C14 Refueling Outage Sleeving Summary STEAM GENERATOR E-088 Sleeves Sleeves Sleeves Sleeves With With with Partial Outage Sleeve Placed in Reduced Reduced Reduction Installed Service Diameter in Diameter Indications U2C13 U2C14 U2C14 1999(U2C10) 85 0

2 1

2000(U2C11) 96 0

1 0

2002 (U2C12) 75 7

14 7

2004 (U2C13) 113 0

27 11 STEAM GENERATOR E-089 Sleeves Sleeves Sleeves Sleeves With With with Partial Outage Sleeve Placed in Reduced Reduced Reduction nstalled Service Diameter in Diameter Indications U2C13 U2C14 U2C14 1999(U2C10) 52 0

1 0

2000(U2C11) 52 0

0 0

2002(U2C12) 43 3

15 6

2004 (U2C13) 51 0

10 3

Inservice Inspection of Steam Generator Tubes Attachment Special Report Page 13 of 26 TABLE 6 - U2C14 Refueling Outage Tubes Plugged STEAM GENERATOR E-088 Row Column Reason for Plugging Tube (per Table 3) 22 4

OD Axial @ Freespan 37 15 OD Axial @ Support 70 22 OD Axial @ Support 72 22 OD Axial @ Support 82 24 OD Axial @ Support 35 25 Wear @ Support 17 27 Sleeve Preventative 6

30 OD Axial @ Support 27 33 ID Circ @ TSH 10 34 ID Circ @ TSH 11 35 Sleeve Preventative 17 35 Sleeve Preventative 23 35 Sleeve! Preventative 18 36 Sleeve Preventative 38 36 Sleeve Preventative 25 39 Sleeve! Preventative 95 39 OD Axial @ Support 25 41 Sleeve! Preventative 18 42 ODAxial @ Support 44 42 OBS @0 Sleeve 7

43 Sleeve Preventative 21 43 OD Axial @ Support 23 43 ID Circ @ TSH 16 44 Sleeve Preventative 52 44 ID Circ @ TSH 6

46 Sleeve Preventative 60 46 ID Circ @ TSH 41 47 OD Axial @ Freespan 22 48 ID Circ @ TSH 15 49 ID Circ @ TSH 25 49 OBS CO Sleeve 33 49 ID Circ @ TSH 35 49 ID Axial below TSH 63 49 OD Circ @ TSH 27 51 ID Circ @ TSH 83 51 ID Circ below TSH 60 52 ID Circ @ TSH 64 52 OBS i Sleeve 16 54 Sleeve Preventative 18 54 OD Axial @ Support

Inservice Inspection of Steam Generator Tubes Attachment Special Report Page 14 of 26 TABLE 6 (Cont.) - U2C14 Refueling Outage Tubes Plugged STEAM GENERATOR E-088 Row Column Reason for Plugging Tube (per Table 3) 32 54 Sleeve Preventative 46 54 OD Circ @ TSH 54 54 ID Cire @ TSH 62 54 ID Circ @ TSH 17 55 ID Axial @ Support 27 55 Sleeve Preventative 45 55 Sleeve! Preventative 49 55 OD Circ @ TSH 57 55 OBS id Sleeve 10 56 Sleeve Preventative 16 56 PCS CO Sleeve 30 56 Sleeve Preventative 46 56 Sleeve Preventative 48 56 Sleeve Preventative 64 56 Sleeve Preventative 13 57 PCS i Sleeve 23 57 Sleeve Preventative 67 57 Sleeve Preventative 20 58 OD Axial @ Support 48 58 Sleeve! Preventative 52 58 OD Axial @ Sludge Pile TSH 90 58 OBS @0 Sleeve 83 59 OBS @t Sleeve 50 60 ID Axial below TSH 17 61 Sleeve Preventative 43 61 OD Axial @ Support 12 62 PCS i Sleeve 18 62 Sleeve Preventative 20 62 Sleeve Preventative 62 62 Sleeve Preventative 11 63 Sleeve Preventative 27 63 ID Axial below TSH 43 63 Sleeve Preventative 83 63 OBS a Sleeve 46 64 ID Cire @ TSH 54 64 Sleeve Preventative 23 65 ID Axial below TSH 41 65 ID Circ below TSH 43 65 Sleeve Preventative 47 65 Sleeve Preventative 49 65 Sleeve Preventative 59 65 OBS © Sleeve 24 66 ID Axial below TSH 60 66 OBS © Sleeve

Inservice Inspection of Steam Generator Tubes Attachment Special Report Page 15 of 26 TABLE 6 (Cont.) - U2C14 Refueling Outage Tubes Plugged STEAM GENERATOR E-088 Row Column Reason for Plugging Tube (per Table 3) 64 66 OBS @ Sleeve 72 66 OD Circ @ TSH 23 67 ID Axial below TSH 33 67 ID Axial below TSH 43 67 Sleeve Preventative 36 68 Sleeve Preventative 44 68 ID Axial below TSH 48 68 OBS @ Sleeve 78 68 Sleeve Preventative 37 69 Sleeve Preventative 47 69 OBS (t Sleeve 65 69 Sleeve Preventative 30 70 OBS @ Sleeve 48 70 Sleeve Preventative 68 70 Sleeve Preventative 70 70 ID Circ @ TSH 45 71 OD Axial @ Support 53 71 PCS @. Sleeve 46 72 OBS @D Sleeve 56 72 Sleeve Preventative 62 72 Sleeve Preventative 82 72 Sleeve Preventative 55 73 OD Axial @ Sludge Pile TSH 48 74 ID Axial below TSH 54 74 Sleeve Preventative 68 74 Sleeve Preventative 74 74 Sleeve Preventative 81 75 ID Circ@ t TSH 99 75 OBS @t Sleeve 145 75 Wear @ Support 44 76 Wear @ Support 70 76 ID Circ @ TSH 98 76 ID Circ @ TSH 53 77 Sleeve Preventative 55 77 Sleeve Preventative 61 77 Sleeve Preventative 63 77 OD Axial @ Sludge Pile TSH 75 77 ID Circ D TSH 131 77 Wear @ Support 48 78 Wear ¢ Support 64 78 Sleeve Preventative 80 78 Sleeve Preventative 116 78 OD Circ @ TSH 53 79 OBS © Sleeve

Inservice Inspection of Steam Generator Tubes Special Report Page 16 of 26 TABLE 6 (Cont) - U2C14 Refueling Outage Tubes Plugged STEAM GENERATOR E-088 Row Column Reason for Plugging Tube (per Table 3) 78 80 Sleeve Preventative 80 80 OD Circ @ TSH 146 80 Wear @ Support 57 81 ID Axial below TSH 63 81 Sleeve Preventative 75 81 ID Circ below TSH 58 82 Wear @ Support 62 82 ID Axial below TSH 74 82 Wear @ Support 57 83 Wear @ Support 67 83 PCS @0 Sleeve 54 84 Wear @ Support 70 84 OBS @ Sleeve 86 84 ID Circ @ TSH 144 84 Wear 0 Support 67 85 Wear @ Support 135 85 OD Axial @ Support 80 86 Sleeve Preventative 77 87 ID Circ: @ TSH 58 88 Sleeve Preventative 78 88 OD Axial @ Sludge Pile TSH 82 88 Sleeve Preventative 71 89 PCS CO Sleeve 79 89 OD Axial @ Support 95 89 ID Circ @ TSH 68 90 OBS At Sleeve 92 90 OD Circ @ TSH 144 90 Wear ( Support 59 91 OBS @0 Sleeve 63 91 PCS it Sleeve 67 91 OBS CO Sleeve 77 91 Sleeve Preventative 56 92 OBS As Sleeve 60 92 Sleeve Preventative 68 92 Sleeve Preventative 98 92 OD Circ @ TSH 55 93 Wear <X Support 69 93 ID Axial below TSH 77 93 Sleeve Preventative 68 94 OBS CO Sleeve 130 94 Wear ( Support 53 95 Sleeve Preventative 85 95 OBS © Sleeve 72 96 OD Axial @ Sludge Pile TSH

Inservice Inspection of Steam Generator Tubes Attachment Special Report Page 17 of 26 TABLE 6 (Cont.) - U2C14 Refueling Outage Tubes Plugged STEAM GENERATOR E-088 Row Column Reason for Plugging Tube (per Table 3) 74 96 OD Axial @ Sludge Pile TSH 76 96 OD Circ @ TSH 51 97 Wear @? Support 55 97 Wear @ Support 63 97 OBS At Sleeve 73 97 Sleeve Preventative 75 97 Sleeve Preventative 77 97 Sleeve Preventative 81 97 OBS id Sleeve 91 97 OBS @0 Sleeve 97 97 Sleeve Preventative 44 98 Wear @ Support 64 98 PCS i Sleeve 61 99 PCS A Sleeve 89 99 Sleeve Preventative 48 100 Wear 0 Support 50 100 Wear 0 Support 68 100 OD Axial @ Sludge Pile TSH 74 100 Sleeve! Preventative 100 100 ID Circ @ TSH 51 101 OD Axial 0 Support 69 101 Sleeve, Preventative 71 101 OD Circ@)TSH 68 102 OBS CO Sleeve 39 103 Wear ( Support 41 103 OBS i Sleeve 49 103 Sleeve Preventative

~57 103 Sleeve Preventative 61 103 Sleeve Preventative 67 103 Sleeve Preventative 69 103 ID Circ below TSH 79 103 Sleeve Preventative 42 104 Sleeve Preventative 52 104 OBS © Sleeve 62 104 ID Circ below TSH 80 104 OBS i? Sleeve 82 104 Sleeve Preventative 47 105 OBS © Sleeve 99 105 ID Axial below TSH 32 106 ID Circ @ TSH 34 106 ID Axial below TSH 36 106 Sleeve Preventative 72 106 Sleeve Preventative 82 106 ID Circ @ TSH

Inservice Inspection of Steam Generator Tubes Attachment Special Report Page 18 of 26 TABLE 6 (Cont.) - U2C14 Refueling Outage Tubes Plugged STEAM GENERATOR E-088 Row Column Reason for Plugging Tube (per Table 3) 30 108 Sleeve Preventative 36 108 PCS @t Sleeve 68 108 ODCirc @ TSH 70 108 PCS @t Sleeve 49 109 Sleeve Preventative 67 109 PCS @ Sleeve 51 111 Sleeve Preventative 55 111 Sleeve Preventative 57 111 Sleeve Preventative 83 111 OBS Am Sleeve 22 112 Sleeve Preventative 42 112 Sleeve Preventative 50 112 Sleeve Preventative 92 112 ID Circ below TSH 17 113 Sleeve, Preventative 31 113 ID Axial @ Support 43 113 Sleeve Preventative 24 114 ID Circ, X TSH 44 114 PCS At Sleeve 46 114 Sleeve Preventative 52 114 PCS XV Sleeve 82 114 OBS A Sleeve 43 115 ID Circ below TSH 73 115 ID Circ @ TSH 44 116 Sleeve Preventative 46 116 Sleeve Preventative 60 116 Sleeve Preventative 13 117 OD Axial @ Support 55 117 Sleeve Preventative 24 118 ID Axial below TSH 28 118 Sleeve Preventative 30 118 OBS 0 Sleeve 13 119 Sleeve Preventative 17 119 ID Axial 0 Support 25 119 Sleeve Preventative 51 119 ID Axial below TSH 57 119 Sleeve Preventative 65 119 Sleeve Preventative 75 119 PCS 0 Sleeve 83 119 PCS a Sleeve 22 120 Sleeve Preventative 7

121 Sleeve Preventative 13 121 OBS 0t Sleeve 27 121 OBS @ Sleeve

Inservice Inspection of Steam Generator Tubes Attachment Special Report Page 19 of 26 TABLE 6 (Cont.) - U2C14 Refueling Outage Tubes Plugged STEAM GENERATOR E-088 Row Column Reason for Plugging Tube (per Table 3) 39 121 Sleeve Preventative 65 121 Sleeve Preventative 83 121 PCS @ Sleeve 10 122 OD Axial @ Support 42 122 Sleeve Preventative 48 122 Sleeve Preventative 19 123 Sleeve Preventative 47 123 Sleeve Preventative 85 123 OD Axial @ Support 14 124 ID Circ > TSH 30 124 ID Circ @ TSH 130 124 ID Axial > Support 51 125 ID Circ. @ TSH 18 126 OD Axial @ Support 60 126 Sleeve Preventative 25 127 OBS t Sleeve 27 127 Sleeve Preventative 29 127 ID Axial below TSH 47 127 Sleeve Preventative 67 127 ID Circ @ TSH 44 128 ID Axial below TSH 11 129 OD Circ @ TSH 8

130 OD Axial @ Support 16 130 ID Axial below TSH 54 130 ID Circ @ TSH 31 131 ID Circ@ > TSH 39 131 OBS CO Sleeve 10 132 PCS CD Sleeve 16 132 ID Circ @ TSH 58 134 PCS @} Sleeve 15 135 OBS CD Sleeve 35 135 ID Axial below TSH 55 135 ID Circ @ TSH 105 135 OD Axial @ Support 78 136 Wear @ Support 15 137 ID Circ below TSH 12 138 ODAxial @ Freespan 18 138 Sleeve Preventative 74 138 OD Axial @ Support 7

139 OBS ©a Sleeve 17 139 ID Circ @ TSH 10 140 ID Circ @ TSH 100 142 OD Axial @ Support 12 144 Sleeve Preventative

Inservice Inspection of Steam Generator Tubes Attachment Special Report Page 20 of 26 TABLE 6 (Cont.) - U2C14 Refueling Outage Tubes Plugged STEAM GENERATOR E-088 Row Column Reason for Plugging Tube (per Table 3) 96 144 OD Axial @ Support 37 147 OBS @ Sleeve 19 149 OD Axial @ Support 35 149 Sleeve Preventative 65 149 OBS @ Sleeve 87 149 OD Axial t Support 33 151 OD Circ @ TSH 57 151 OBS t Sleeve 83 151 OD Axial @ Support 6

152 OD Axial @ Support 72 156 OD Axial @ Support 69 157 OD Axial @ Support 17 161 OD Axial @ Support 49 165 OD Axial @ Support

Inservice Inspection of Steam Generator Tubes Attachment Special Report Page 21 of 26 TABLE 7 - U2C14 Refueling Outage Tubes Plugged STEAM GENERATOR E-089 Row Column Reason for Plugging Tube (per Table 3) 52 12 OD Axial @ Support 14 16 ID Axial below TSH 80 24 OD Axial @ Support 87 25 ID Axial @ Support 94 30 OD Axial @ Support 88 32 OD Axial @ Support 91 35 ID Axial @ Support 39 37 Sleeve Preventative 12 38 ID Circ@ { TSH 56 38 OBS 0 Sleeve 55 41 ID Circ @ TSH 16 42 OBS @ Sleeve 20 42 OD Axial @ Support 28 42 Sleeve Preventative 81 43 Wear X Support 91 43 OD Axial @ Sludqe Pile TSH 46 44 Sleeve Preventative 92 44 OD Axial @ Sludge Pile TSH 9

45 ID Axial below TSH 29 45 OD Axial @ Support 100 46 Sleeve Preventative 116 46 ODAxial @ Support 45 47 PCS h Sleeve 24 48 OBS @ Sleeve 29 49 Sleeve Preventative 41 49 OD Axial @ Support 47 49 Sleeve Preventative 36 50 OD Circ @ TSH 35 51 OD Axial @ Sludge Pile TSH 50 52 PCS @ Sleeve 126 52 OD Axial @ Freespan 11 53 OD Axial © Support 25 53 OD Circ @ TSH 29 53 OD Circ @ TSH 39 53 OBS 0 Sleeve 103 53 OD Axial @ Support 22 54 OD Axial @ Support 24 54 PCS @ Sleeve 30 54 PCS CD Sleeve 44 54 OBS @ Sleeve 84 54 OD Axial @ Support 90 56 OD Axial @ Support

Inservice Inspection of Steam Generator Tubes Attachment Special Report Page 22 of 26 TABLE 7 (Cont.) - U2C14 Refueling Outage Tubes Plugged STEAM GENERATOR E-089 Row Column Reason for Plugging Tube (per Table 3) 11 57 OD Axial @ Support 16 58 Sleeve Preventative 20 58 OD Circ @ TSH 37 59 Sleeve Preventative 20 60 Sleeve! Preventative 22 60 Sleeve Preventative 34 60 OD Circ @ TSH 38 60 PCS CO Sleeve 11 61 OD Circ @ TSH 35 61 Sleeve Preventative 64 62 ID Circ @ TSH 71 63 OBS @ Sleeve 50 64 OD Axial @ Support 31 65 OBS @ Sleeve 43 65 PCS hi Sleeve 64 66 OBS ID Sleeve 70 66 Sleeve Preventative 39 67 Sleeve Preventative 45 67 Sleeve Preventative 69 67 OD Axial @ Sludge Pile TSH 55 69 OBS @P Sleeve 57 69 OBS @ Sleeve 54 70 OD Axial @ Sludge Pile TSH 67 71 Sleeve Preventative 75 71 OD Circ @ TSH 46 72 Sleeve Preventative 76 72 OD Circ @ TSH 75 73 Sleeve Preventative 143 73 Wear @ Support 48 74 OBS @t Sleeve 56 74 OD Circ @ TSH 78 74 Sleeve Preventative 102 74 ID Circ @ TSH 120 74 Wear @ Support 51 75 OBS @ Sleeve 59 77 OD Circ @ TSH 79 77 OD Axial @ Sludge Pile TSH 50 78 Sleeve Preventative 54 78 Sleeve Preventative 57 81 OBS ( Sleeve 65 81 PCS @ Sleeve 145 81 Wearer Support 60 82 ID Axial below TSH 86 82 PCS At Sleeve

Inservice Inspection of Steam Generator Tubes Attachment Special Report Page 23 of 26 TABLE 7 (Cont.) - U2C14 Refueling Outage Tubes Plugged STEAM GENERATOR E-089 Row Column Reason for Plugging Tube (per Table 3) 56 84 Wear @ Support 62 84 Wear X Support 68 84 OBS CO Sleeve 89 85 Sleeve Preventative 96 86 ID Axial below TSH 64 88 OBS CO Sleeve 66 88 Wear @ Support 111 89 OD Circ @ TSH 61 93 OBS @ Sleeve 85 93 Sleeve Preventative 95 93 Sleeve Preventative 83 95 Sleeve Preventative 84 96 OBS CD Sleeve 101 97 Sleeve Preventative 59 99 OBS i Sleeve 61 99 OD Circ @ TSH 62 100 Sleeve Preventative 43 101 Wear < Support 41 103 OBS X Sleeve 57 103 Sleeve Preventative 59 103 OD Axial @ Freespan 143 103 Wear @ Support 106 104 Sleeve Preventative 57 105 Sleeve Preventative 75 105 Sleeve Preventative 116 106 Sleeve Preventative 37 107 Sleeve Preventative 51 107 Sleeve Preventative 97 107 Sleeve Preventative 48 108 OBS i Sleeve 68 108 ID Axial below TSH 47 109 Sleeve Preventative 26 110 Sleeve Preventative 30 110 OD Axial @ Sludge Pile TSH 37 111 ID Axial below TSH 24 112 OBS X Sleeve 8

114 OBS Ca Sleeve 18 114 Sleeve Preventative 118 114 ID Axial below TSH 13 115 OD Axial @ Support 25 115 PCS t Sleeve 29 115 Sleeve Preventative 35 115 Sleeve Preventative 77 115 Sleeve Preventative

Inservice Inspection of Steam Generator Tubes Attachment Special Report Page 24 of 26 TABLE 7 (Cont.) - U2C14 Refueling Outage Tubes Plugged STEAM GENERATOR E-089 Row Column Reason for Plugging Tube (per Table 3) 93 115 Sleeve Preventative 12 116 ID Axial below TSH 38 116 OBS OD Sleeve 26 118 Sleeve Preventative 28 118 OBS @ Sleeve 85 119 Sleeve Preventative 12 120 Sleeve Preventative 57 121 ID Axial below TSH 20 122 OD Axial @ Support 85 123 Sleeve Preventative 64 124 ID Axial below TSH 53 125 Sleeve Preventative 81 125 Sleeve Preventative 24 126 OD Axial @ Support 36 126 OBS ( Sleeve 33 127 Sleeve Preventative 38 128 OD Circ @ TSH 102 130 OD Circ @ TSH 3

131 ID Circ below TSH 36 132 Sleeve Preventative 36 134 Sleeve Preventative 27 137 ID Circ; @ TSH 12 138 Sleeve Preventative 13 139 Sleeve Preventative 8

140 ID Circ below TSH 10 140 Sleeve Preventative 14 140 OD Circ @ TSH 11 141 Sleeve! Preventative 10 142 ID Circ below TSH 81 145 ID Axial below TSH 9

147 OBS @ Sleeve 27 147 Sleeve Preventative 45 147 OD Axial @ Support 8

156 ID Circ @ TSH 65 157 OD Axial @ Support 54 158 OD Axial @ Freespan

Inservice Inspection of Steam Generator Tubes Attachment Special Report Page 25 of 26 TABLE 8 - Measured Sizes of Service-Induced Indications STEAM GENERATOR E-088 Row Col Eiev Inch Ind Origin PP Volts Depth PDA FLDA PP Length CA 10 34 TSH

-0.06 SCI ID 0.64 71 4.17 30 16 130 TSH

-4.4 SAI ID 0.74 58 N/A 2.17 17 55 06H 0.3 SAI ID 0.99 22 N/A 0.29 17 119 106H 0.48 SAI ID 0.88 60 57.10 0.3 17 139 TSH

-0.05 SCI ID 0.85 59 5.11

=

45 22 48 TSH

-0.13 SCI ID 0.92 59 3.78 31 24 66 TSH

-1.8 SAI ID 0.49 40 N/A 0.33 24 118 TSH

-1.72 SAI ID 0.61 49 40.30 0.2 271 33 TSH

-0.141SCI ID 1.16 50 2.83 ___33 27 63 TSH

-0.91 SAI ID 0.84 36

=

NtA 0.16 =

27 63 TSH

-1.09 SAI ID 0.62 42 N/A 0.17 29 12 TSH

-1.07 SAI ID 0.66 46 N/A 0.12 31 113 06H 0.4 SAI ID 1.16 57

=

45.52 0.29 33 49 TSH

-0.08 SCI ID 0.41 51 2.76 31 33 67 TSH

-3.01 SAl ID 0.56 39 NIA 0.13 _

34 106 TSH

-3.73 SAI ID 0.64 49 ___44.60 0.17 _

35 49 TSH

-1 3.34 SAI ID 0.99 35 NIA 5.63 35 49 TSH

-8.31 SAI ID 1.12 49 N/A 8.71 _

35 135 TSH

-2.99 SAI ID 0.63 40 NIA 0.3 _

44 68 TSH

-1.72 SAI ID 0.59 57 N/A 0.17 44 128 TSH

-2.08 SAI ID 0.66 33 NIA 0.14 45 71 05H 0.42 SAI OD 0.68 52 35.52 0.27 50 60 TSH

-1.63 SAI ID 0.57 60 N/A 0.19 51 119 TSH

-5.53 SAI ID 0.55 47 42.91 0.17 _

51 125 TSH

-0.02 SCI ID 0.41 47 2.511 31 55 135 TSH

-0.09 SCI ID 0.76 62 4.05 35 57 81 TSH

-1.39 SAI ID 0.5 47 N/A 0.73 60 52 TSH

-0.11 SCI ID 0.8 83 5.64 39 62 82 TSH

-1.2 SAI ID 0.57 45 N/A 0.2 _

67 127 TSH

-0.08 SCI ID 0.65 56 3.22 30 69 93 TSH

-3.88 SAI ID 0.84 57 N/A 0.18 _

69 103 TSH

-9.63 SCI ID 0.4 51 2.37 26 75 77 TSH 0.01 SCI ID 0.71 77 16.19 79 77 87 TSH

-0.2 SCI ID 0.56 58 6.28 49 81 75 TSH

-0.04 SCI ID 0.47 67 3.23 28 86 84 TSH

-0.05 SCI ID 0.5 42 1.88 26 86 84 TSH

-0.04 SCI ID 0.61 58 2.47 26 98 76 TSH

-0.1 SCI ID 0.48 41 2.59 28 99 105 TSH

-0.22 SAI ID 0.71 34 N/A 0.23 _

100 142 06H 0.54 SAI OD 0.48 46 26.09 1.04 _

130 124 06H 0.11 SAl ID 1.44 21

=

13.38 0.13 _

See notes following Table 9

Inservice Inspection of Steam Generator Tubes Attachment Special Report Page 26 of 26 TABLE 9 - Measured Sizes of Service-Induced Indications STEAM GENERATOR E-089 Row Col Elev Inch Ind

_dg PP Volts

-pth PDA FLDA PPLength CA 3 131 TSH

-1.82 SCI ID 0.51 59 2.791 27 8 156 TSH

-0.06 I01 ID 0.55 47 3.87 30 9

45 TSH

-15.04 SAI ID 0.58 47 N/A 0.17 1

142 TSH

-6.14 SCI ID 0.83 54 2.89 35 14 16 TSH

-10.51 SAI ID 0.79 57

=

N/A 0.2 =

24 126 070 0.71 SAI OD 0.55 44 33.15 1.38 27 137 TSH

-0.01 SCI ID 0.47 57 3.40 30 57 121 TSH

-3.18 SAI ID 0.91 55 N/A 0.15 64 124 TSH

-11.64 SAI ID 0.32 55 N/A 0.17 68 108 TSH -14.24 SAI ID 0.69 60 N/A 0.16 81 145 TSH

-5.34 SAI ID 0.66 55 N/A 0.17 87 25 04H 0.3 SAI ID 1.6 53 42.45 0.22 87 25 04H 0.68 SAI ID 1.36 44 38.42 0.17 91 35 05H 0.18 SAI ID 1.64 4

44.86 0.29 96 86 TSH

-11.91 SAI ID 1.22 39 N/A 0.18 118E 114 TEH 3.24 SAI ID 3.57 92 78.74

0.4 Notes

PP = Plus Point PDA = Percent Degraded Area FLDA = Flaw-Length Degraded Area CA = Crack Angle (degrees)

Inservice Inspection of Steam Generator Tubes Attachment Special Report Page 1 of 4 Appendix 1 Steam Generator Reference Information

Inservice Inspection of Steam Generator Tubes Special Report Attachment Page 2 of 4 Steam Generator CE Model 3410 Tube Support Drmwing

_ is" ir i" i" i_

l Om-100 09H 090 08H

=08C 07H l

07C Joe 06H l

06C 05H l

=

05C 04H

-04C 03H 03C 36' 02H

=

=

02C 355 01H 01C TSH TSC TEH TEC L1

Inservice Inspection of Steam Generator Tubes Attachment Special Report Page 3 of 4 STEAM GENERATOR TUBE SUPPORT INTERSECTIONS ABOVE THE 7 TH (FULL) EGGCRATE SUPPORT SUPPORT INTERSECTIONS ROW STRUCTURES 122-147 08H 09H 10H DBH VH1 IVH2 VHI3 VSM VC3 VC2 VC1 DBC 10C 09C 08C 120-121*

08H 09H 10H DBH VH1 VH.2 VH3 VSM VC3 VC2 VC1 DBC 10C 09C 08C 115-119 08H 09H DBH VH1 VH2 VH3 VSM VC3 VC2 VC1 DBC 09C 08C 86-114 08H 09H DBH VH,2 VH3 VSM VC3 VC2 DBC 09C 08C 84-85*

08H 09H DBH VH:2 VH3 VSM VC3 VC2 DBC 09C 08C 83 08H DBH VH:2 VH3 VSM VC3 VC2 DBC 08C 51-82 08H DBH VH3 VSM VC3 DBC 08C 49-50*

08H DBH1_

VSM DBC 080 19-48 DBH VSM DBC 1-18 DBH IDB

  • Indicates those rows adjacent to scallop bars

Inservice Inspection of Steam Generator Tubes Attachment Special Report Page 4 of 4 SOUTHERN CALIFORNIA EDISON, SAN ONOFRE CE MODEL 3410 STEAM GENERATOR I,

2 30 59 go 70 so g

1*

IN 120 13 140 10 ISO lye 1*

130 120 110 jiw 50 80 50 30 60 se 00 0

0000000 0

0gg ooo 00oo6~

~oooo ~~~

o.o90.%000000008**O8 ooo88Oo0 0 000o00o 00008 O

o o

000080000 00 00088888§9oo8~

~~~

~~~oo0~Q0~ ~

8~~~

o.ooOl oo0 880 0800 0000000000 10 2

0 40 50 O0.

.0 20 10 10 10 1

5 7

I 0

0 oo 15 D

010410-0':1-0 o.~~0 4~..2 O 0-0000 0 0e.---20Cs0 0

1@

130 120 lie F

- 60 4n

--Q0 4

0O'D

111 I

-N5 40

- 30 10 l00000 0070;0 to 24 D0P0so so 7e $0 se 10 Ie in in 14 M5 to 17e

Inservice Inspection of Steam Generator Tubes Attachment Special Report Page 1 of 2 Appendix 2 Legend for Appendices 3 through 6

Inservice Inspection of Steam Generator Tubes Attachment Special Report Page 2 of 2 List of Abbreviations and Format Used to Describe Indications from Rotating Probe Thsting Abbreviations Explanation of the Abbreviations SCI Single Circumferential Indication MCI Multiple Circumferential Indications SAI Single Axial Indication MAI Multiple Axial Indications MMI Mixed Mode Indications SVI Single Volumetric Indication (i.e. no special axial or circumferential aspect)

MVI Multiple Volumetric Indications (i.e. no special axial or circumferential aspect)

OBS Obstruction PCS Partially obstructed sleeve Format In Appendices 3 through 6, a single line of data is associated with each individual rotating probe indication. Below is a descriptive example of the format.

All "I-Code" indications require a single line entry. The example above displays the form of a Resolution Report line.

The VOLTS field contains the Plus Point P-to-P voltage of the largest, most representative response. The DEG field contains the corresponding phase angle. The CHN field contains the reporting channel (i.e. the appropriate 300kHz Plus Point channel). The IND field contains the appropriate 3-letter code (see list above). The %TW field indicates the percent wall loss for wear indications. The LOCATION field contains the abbreviation for the referenced landmark and the (FROM-TO) distance for the indication. The EXT fields contain the landmarks of the beginning and end of the test extent. The UTIL 1 field contains the 300kHz pancake P-to-P voltage of the largest, most representative response.

Exceptions to this general guidance are provided in paragraphs 2 through 5 below.

2.

For axial indications of extended length, the location should be ranged (FROM-TO) in the LOCATION field. If the range of such an indication includes any part of a support structure, it should be referenced from that landmark.

3.

For 'I-Code" indications which have both axial and circumferential extent (i.e. SVI, MVI, and MMI), the location should be ranged in the LOCATION field (as above) and the UTIL 2 field should contain the circumferential length.

4.

Some data lines contain a note abbreviation in the Util 1 column. These are the definitions of these abbreviations:

LAR: Lead Analyst Reviewed LOCOK: Location Verification

5.

Some data lines contain location codes that are not reflected in Appendix 1 references. These codes and the definition of their locations include:

SBH - Sleeve Bottom Hot STH - Sleeve Top Hot WCH - Weld Center Hot

Inservice Inspection of Steam Generator Tubes Attachment Special Report Page 1 of 15 Appendix 3 Tube Inspection Summary Steam Generator E-088

Framatome ANP Inc.

Customer Name: San Onofre -

Unit 2 1/24/2006 2:38:44 PM Component: S/G 88 Page 2 of 15 MAI, MCI, MMI, MVI, SAI, SCI, SVI, 0-100%

QUERY: rpc_icodes and_0-100%twd ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 6

30 0.37 87 2

SAI 07C

+0.64 07C DBC 0.25 98 COLD 580PP 0.17 120 2 SAI 04H

-0.83 04H 04H 0.15 213 HOT 580PP 6

152 0.45 74 2

SAI 07H

-0.07 07H 07H 0.20 228 HOT 580PP 0.32 58 2

SAI 07H

-0.27 07H 07H 0.13 228 HOT 580PP 0.26 55 2

SAI 07H

-0.55 07H 07H 0.18 228 HOT 58OPP 6

168 0.19 155 P2 TWD 14 04H

-0.35 TEC TEH 48 HOT 600UL 8

130 0.31 139 2 SAI 07H

-0.26 07H 07H 0.20 228 HOT 580PP 10 34 0.51 22 P1 SCI TSH

-0.06 TSH TSH 0.17 72 HOT 580PP 10 122 0.20 129 2 SAI 05H

+0.75 05H 05H 0.43 228 HOT 580PP 10 140 0.37 26 P1 SCI TSH

-0.01 TSH TSH 0.20 83 HOT 58OPP 11 129 0.16 123 P1 SCI TSH

-0.02 TSH TSH 0.24 108 HOT 580PP 12 138 0.16 98 2

SAI 02H

+4.50 02H 02H 0.77 269 HOT 520ET 0.21 100 2 SAI 02H

+5.06 02H 02H 0.83 269 HOT 520ET 13 9

0.32 70 P2 TWD 17 05H

-0.12 TEC TEH 39 HOT 600UL 13 117 0.49 120 P2 TWD 19 07C

+0.28 TEH TEC 34 COLD 600UL 0.37 87 2

SAI 07C

+0.28 07C 07C 0.27 98 COLD 580PP 14___124__0__31___21__P1____C___T____-0.08________T_________TSH______0.15________109______HOT__________________

14 124 0.31 21 P1 SCI TSH

-0.08 TSH TSH 0.15 109 HOT 580PP 15 49 0.37 21 Pl SCI TSH

-0.02 TSH TSH 0.16 215 HOT 580PP 15 119 0.30 130 P2 TWD 16 07C

-0.83 TEH TEC 35 COLD 600UL 15 137 0.29 22 P1 SCI TSH

-9.16 TSH TSH 0.27 116 HOT 580PP 16 130 0.73 21 2

SAI TSH

-4.40 TO-2.23 TSH TSH 2.14 108 HOT 58OPP 16 132 0.32 29 P1 SCI TSH

-0.07 TSH TSH 0.20 113 HOT 580PP 0.48 16 2 SAI TSH

-8.80 TSH TSH 0.17 113 HOT 58OPP 17 55 0.97 8

2 SAI 06H

+0.30 06H 06H 0.29 217 HOT 58OPP 17 119 0.88 21 2

SAI 06H

+0.48 06H 06H 0.26 240 HOT 580PP 17 139 0.71 25 P1 SCI TSH

-0.05 TSH TSH 0.30 120 HOT 580PP 17 161 0.24 121 2 SAI 06H

+0.80 1

06H 06H 0.25 189 HOT 580PP 0.34 141 P2 TWD 17 06H

+0.74 TEC TEH 30 HOT 600UL 18 42 0.30 91 2

SAI 01H

-0.54 01H 01H 0.27 268 HOT 520ET 18 44 0.20 90 P3 TWD 10 DBH

-2.00 TEC TEH 16 HOT 600UL 18 54 0.23 122 2 SAI 02H

-1.12 02H 02H 0.27 268 HOT 520ET 18 126 0.23 112 2 SAI 06H

-0.41 06H 06H 0.14 269 HOT 520ET 19 135 0.46 87 P3 TWD 17 DBH

+2.08 i

TEC TEH 11 HOT 600UL 19 149 0.30 87 2

SAI 06H

+0.28 06H 06H 0.25 190 HOT 58OPP 19 159 0.27 62 P2 TWD 14 03H

+0.93 TEC TEH 30 HOT 600UL 20 58 0.19 96 2

SAI 02H

-1.13 02H 02H 0.24 268 HOT 520ET 20 68 0.26 37 P3 TWD 22 DBH

-1.73 TEH TEC 37 COLD 600UL 20 108 0.19 16 P3 TWD 6 DBH

-1.61 TEH TEC 54 COLD 600UL 21 43 0.25 115 2 SAI 05H

+0.79 05H 05H 0.33 208 HOT 580PP 21 67 0.35 54 P3 TWD 14 DBH

+1.94 TEH TEC 36 COLD 600UL 22 4

0.19 116 2 SAI 04H

-1.39 04H 04H 0.40 211 HOT 58OPP 22___48__0.60____25__P1____C____T____-0.13________T____E____TSH______0.21________114______HOT__________________

22 48 0.60 25 Pl SCI TSH

-0.13 TSH TSH 0.21 114 HOT 580PP

Framatome ANP Inc.

1/24/2006 2:38:44 PM Customer Name: San Onofre -

Unit 2 Component: S/G 88 Page 3 of 15 MAI, MCI, MMI, MVI, SAI, SCI, SVI, 0-100%

QUERY: rpc icodes and 0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 23 43 0.25 18 P1 SCI TSH

-0.10 TSH TSH 0.18 107 HOT 580PP 23___65__0.35____16__2__S_____TS____-1.38________T__SH_____T________0.19________126______HOT__________________

23 65 0.35 16 2 SAI TSH

-1.38 TSH TSH 0.19 126 HOT 580PP 23 67 0.36 20 2

SAI TSH

-0.53 TSH TSH 0.16 126 HOT 580PP 23 109 0.54 128 P2 TWD 20 VSM

+0.89 TEH TEC 32 COLD 600UL 24 14 0.25 76 P2 TWD 13 VSM

+0.87 TEC TEH 33 HOT 60OUL 24 66 0.57 14 2 SAI TSH

-1.80 TSH TSH 0.19 126 HOT 58OPP 24 114 0.33 25 P1 SCI TSH

-0.16 TSH TSH 0.20 101 HOT 580PP 24 118 0.66 17 2

SAI TSH

-1.72 TSH TSH 0.14 105 HOT 580PP 24 156 0.34 76 P2 TWD 17 03H

+0.83 TEC TEH 30 HOT 600UL 26 146 0.09 16 P3 TWD 9 DBH

+0.28 TEC TEH 21 HOT 600UL 27_3_.60 25P1_C T_

-0.14--------------T------------TSH-------

0.17_________99_________HOT________________________

27 33 0.60 25 P1 SCI TSH

-0.14 TSH TSH 0.17 99 HOT 58OPP 27 51 0.24 24 P1 SCI TSH

-0.13 TSH TSH 0.15 115 HOT 580PP 27 63 0.85 13 2

SAI TSH

-0.91 TSH TSH 0.16 127 HOT 580PP 0.63 14 2

SAI TSH

-1.09 TSH TSH 0.17 127 HOT 58OPP 29 127 0.66 14 2

SAI TSH

-1.07 TSH TSH 0.12 109 HOT 58OPP 30 40 0.36 71 P2 TWD 19 02H

-1.16 TEC TEH 15 HOT 600UL 30 124 0.32 25 P1 MCI TSH

-0.05 TSH TSH 0.29 109 HOT 58OPP 31 11 0.32 35 P3 TWD 16 DBH

+1.48 TEC TEH 32 HOT 600UL 31 113 1.14 19 2 SAI 06H

+0.40 06H 06H 0.29 240 HOT 580PP 31 131 0.42 21 P1 SCI TSH

-0.10 TSH TSH 0.17 113 HOT 580PP 32 4

0.28 118 P2 TWD 14 01C

-0.89 TEC TEH 41 HOT 600UL 32 106 0.20 29 P1 SCI TSH

-0.13 TSH TSH 0.17 97 HOT 580PP 33 49 0.55 19 P1 SCI TSH

-0.08 TSH TSH 0.20 114 HOT 580PP 33 67 0.59 14 2 SAI TSH

-3.01 TSH TSH 0.13 127 HOT 580PP 33 105 0.22 110 P3 TWD 13 DBC

-2.03 TEH TEC 33 COLD 600UL 0.32 139 P3 TWD 17 DBH

-1.75 TEH TEC 33 COLD 600UL 0.13 182 P3 TWD 8 DBC

+1.52 TEH TEC 33 COLD 600UL 33 151 0.28 118 P1 SCI TSH

+0.22 TSH TSH 0.38 137 HOT 580PP 34 106 0.64 17 2 SAI TSH

-3.73 TSH TSH 0.16 96 HOT 58OPP 34 162 0.27 93 P2 TWD 14 VSM

+0.81 TEC TEH 30 HOT 600UL 35 25 0.27 49 P2 TWD 15 VSM

+0.88 TEC TEH 24 HOT 600UL 0.74 88 P2 TWD 30 VSM

-0.88 TEC TEH 24 HOT 600UL 35 49 0.98 13 2

SAI TSH

-13.34 TO-8.71 TSH TSH 5.63 115 HOT 580PP 1.10 16 2

SAI TSH

-8.31 TO+0.40 TSH TSH 8.71 115 HOT 580PP 35 71 0.55 135 P3 TWD 20 DBC

-2.17 TEH TEC 36 COLD 600UL 35 135 0.65 13 2

SAI TSH

-2.99 TSH TSH 0.3 116 HOT 58OPP 37 15 0.30 92 2

SAI 06H

+0.49 06H 06H 0.48 211 HOT 58OPP 37 47 0.42 132 P2 TWD 20 VSM

+0.81 TEH TEC 43 COLD 600UL 37 61 0.42 142 P2 TWD 16 VSM

+0.95 TEH TEC 40 COLD 600UL 38__24__0.43___46__P2__TWO__22_______-0.78___________TEC_________TEH________24_______HOT_________________0_____

38 24 0.43 46 P2 TWD 22 VSM

-0.78 TEC TEH 24 HOT 600UL

Framatome ANP Inc.

1/24/2006 2:38:44 PM Customer Name: San Onofre -

Unit 2 Component: S/G 88 Page 4 of 15 MAI, MCI, MMI, MVI, SAI, SCI, SVI, 0-100%

QUERY: rpcicodes and_0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 39 43 0.44 12 P3 TWD 19 DBC

+1.32 TEC TEH 16 HOT 600UL 39 71 0.44 139 P3 TWD 16 DBC

-2.21 TEH TEC 36 COLD 600UL 39 103 0.68 117 P3 TWD 29 DBC

+1.80 STH TEC 49 COLD 600UL 41 7

0.23 88 P2 TWD 12 VSM

-0.85 TEC TEH 39 HOT 600UL 41 47 0.12 130 2 SAI 01H

+15.98 01H 01H 0.34 224 HOT 58OPP 41 65 0.18 23 P1 SCI TSH

-4.39 TSH TSH 0.18 126 HOT 58OPP 41 73 0.27 126 P3 TWD 23 DBC

+1.60 TEH TEC 37 COLD 600UL 0.32 130 P2 TWD 19 VSM

+1.00 TEH TEC 37 COLD 600UL 41 101 0.11 150 P2 TWD 9 VSM

-0.80 TEC TEH 43 HOT 600UL 0.26 91 P3 TWD 19 DBC

+2.06 TEC TEH 43 HOT 600UL 0.18 137 P3 TWD 14 DBH

-1.44 TEC TEH 43 HOT 600UL 42 74 0.36 26 P3 TWD 12 DBC

-1.78 TEH TEC 54 COLD 600UL 0.47 22 P3 TWD 16 DBC

+1.59 TEH TEC 54 COLD 600UL 42 106 0.68 134 P2 TWD 24 VSM

-0.83 TEH TEC 32 COLD 600UL 42 158 0.07 55 P3 TWD 6 DBH

+1.29 TEC TEH 31 HOT 600UL 43 19 0.58 87 P2 TWD 26 02H

+0.84 TEC TEH 28 HOT 600UL 43 51 0.77 114 P2 TWD 29 VSM

+0.89 TEH TEC 43 COLD 60OUL 43 57 0.47 13 P3 TWD 23 DBC

+2.04 STH TEC 51 COLD 600UL 43 61 0.26 96 2 SAI 03H

-0.41 03H 03H 0.22 217 HOT 580PP 43 73 0.29 85 P3 TWD 13 DBC

-2.01 TEH TEC 36 COLD 600UL 43 101 0.26 74 P3 TWD 19 DBC

-1.75 TEC TEH 43 HOT 600UL 0.16 9

P3 TWD 13 DBC

+2.07 TEC TEH 43 HOT 600UL 43 115 0.34 19 P1 MCI TSH

-2.39 TSH TSH 0.25 101 HOT 580PP 43 125 0.38 151 P2 TWD 19 VSM

-0.81 TEH TEC 35 COLD 600UL 44 58 0.23 15 P2 TWD 12 VSM

-1.07 TEH TEC 41 COLD 600UL 0.32 132 P2 TWD 16 VSM

+0.83 TEH TEC 41 COLD 600UL 44 68 0.67 21 2

SAI TSH

-1.72 TSH TSH 0.19 123 HOT 580PP 44 76 0.56 155 P3 TWD 25 DBH

+1.79 STH TEC 4

COLD 600UL 0.07 22 P3 TWD 3 DBH

-1.78 STH TEC 4

COLD 600UL 44 98 0.79 18 P3 TWD 35 DBH

+1.48 TEC TEH 43 HOT 600UL 0.30 174 P3 TWD 21 DBC

+1.71 TEC TEH 43 HOT 600UL 0.20 137 P3 TWD 15 DBH

-1.49 TEC TEH 43 HOT 600UL 0.09 133 P3 TWD 8 DBC

-1.67 TEC TEH 43 HOT 600UL 44 124 0.33 80 P2 TWD 18 VSM

-0.99 TEH TEC 35 COLD 600UL 44 128 0.66 13 2

SAI TSH

-2.08 TSH TSH 0.19 108 HOT 580PP 45 71 1.01 150 2 SAI 05H

+0.42 05H 05H 0.38 271 HOT 520ET 45 73 0.41 107 P3 TWD 18 DBC

-1.89 STH TEC 51 COLD 600UL 45 145 0.25 103 P2 TWD 13 VSM

+0.85 TEC TEH 17 HOT 600UL 46 6

0.46 43 P2 TWD 21 VSM

-0.78 TEC TEH 41 HOT 600UL 0.16 150 P3 TWD 11 DBC

+1.84 TEC TEH 41 HOT 600UL 46 54 0.19 108 P1 SCI TSH

+0.03 TSH TSH 0.12 119 HOT 580PP 46 64 0.45 24 P1 SCI TSH

-0.11 TSH TSH 0.18

- 123 HOT 580PP 47 109 0.41 121 P2 TWD 19 VSM

+0.87 STH TEC 48 COLD 600UL 47 125 0.29 116 P2 TWD 16 VSM

+0.76 TEH TEC 35 COLD 600UL

Framatome ANP Inc.

1/24/2006 2:38:44 PM Customer Name: San Onofre -

Unit 2 Component: S/G 88 Page 5 of 15 MAI, MCI, MMI, MVI, SAI, SCI, SVI, 0-100%

QUERY: rpc icodes and_0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 48 74 0.45 19 2 SAI TSH

-1.49 TSH TSH 0.17 111 HOT 580PP 48 76 0.44 54 P3 TWD 17 DBC

-1.74 TEC TEH 37 HOT 600UL 0.13 11 P3 TWD 5 DBH

+1.41 TEC TEH 37 HOT 600UL 48 78 0.86 29 P3 TWD 32 DBH

+0.00 STH TEC 4

COLD 600UL 48 100 1.01 12 P3 TWD 39 DBC

+1.59 TEC TEH 43 HOT 600UL 0.12 169 P3 TWD 10 DBC

-1.52 TEC TEH 43 HOT 600UL 48 148 0.36 29 P3 TWD 14 DBC

+2.00 TEC TEH 22 HOT 600UL 49 55 0.13 105 P1 SCI TSH

+0.06 TSH TSH 0.14 118 HOT 58OPP 49 75 0.33 101 P3 TWD 11 DBH

-1.38 TEH TEC 54 COLD 600UL 49 165 0.29 48 2

SAI 06H

+0.11 06H 06H 0.19 194 HOT 58OPP 50 8

0.27 136 P2 TWD 15 VSM

+0.82 TEC TEH 39 HOT 600UL 50 60 0.56 21 2

SAI TSH

-1.63 TSH TSH 0.19 126 HOT 580PP 50 72 0.22 160 P3 TWD 19 DBC

+2.04 TEH TEC 37 COLD 600UL 50 98 0.40 101 P2 TWD 25 VSM

-0.81 TEC TEH 43 HOT 600UL 50 100 0.44 117 P3 TWD 26 DBC

-1.80 TEC TEH 43 HOT 600UL 50 110 0.58 122 P2 TWD 22 08H

+0.68 TEH TEC 32 COLD 600UL 50 124 0.36 142 P2 TWD 15 VSM

+0.90 TEH TEC 34 COLD 600UL 50 164 0.33 57 P2 TWD 16 VSM

+0.83 TEC TEH 30 HOT 600UL 51__________

81___0.51__131___P3__TW___19__DEC__-1.53

__________TEC

_______TE_________

42______ HOT________________

51 81 0.51 131 P3 TWD 19 DBC

-1.53 TEC TEH 42 HOT 600UL 0.51 171 P3 TWD 19 DBH

+1.50 TEC TEH 42 HOT 600UL 0.48 147 P3 TWD 18 DBC

+1.93 TEC TEH 42 HOT 600UL 0.39 144 P3 TWD 16 DBH

-1.53 TEC TEH 42 HOT 600UL 51 97 0.74 82 P3 TWD 25 DBH

+1.27 TEC TEH 42 HOT 600UL 51 101 0.38 113 2 SAI 06H

-0.01 06H 06H 0.25 273 HOT 520ET 51 119 0.55 18 2

SAI TSH

-5.53 TSH TSH 0.17 104 HOT 580PP 51 125 0.63 29 P1 SCI TSH

-0.02 TSH TSH 0.20 109 HOT 580PP 51 163 0.35 57 P2 TWD 22 VH3

+0.85 TEC TEH 31 HOT 600UL 52 44 0.37 16 P1 SCI TSH

-0.16 TSH TSH 0.16 107 HOT 58OPP 52 58 0.21 102 2 SAI TSH

+0.18 TSH TSH 0.14 122 HOT 580PP 52 76 0.29 35 P3 TWD 12 DBC

-1.35 TEC TEH 37 HOT 600UL 53 77 0.43 95 P3 TWD 21 DBC

-1.42 STH TEC 4

COLD 600UL 53 95 0.33 145 P3 TWD 15 DBC

-1.75 STH TEC 2

COLD 600UL 54 8

0.35 39 P2 TWD 18 01H

+0.00 TEC TEH 39 HOT 600UL 0.18 135 P2 TWD 10 01H

-1.01 TEC TEH 39 HOT 600UL 54 54 0.36 18 P1 SCI TSH

-0.11 TSH TSH 0.17 119 HOT 580PP 54 76 0.37 115 P3 TWD 24 DBC

-1.74 TEC TEH 38 HOT 600UL 54 84 0.43 30 P3 TWD 26 DBH

+1.27 TEC TEH 43 HOT 600UL 54 92 0.21 92 P3 TWD 9 DBH

-1.47 TEC TEH 42 HOT 600UL 54 96 0.59 89 P3 TWD 22 DBH

-1.75 STH TEC 2

COLD 600UL 54 130 0.40 26 P1 SCI TSH

-0.02 TSH TSH 0.15 109 HOT 58OPP 55____73____0.17______103____2___S___l___TSR____-+0.56______TSR_____TSR_____0.33_____________HOT______________

55 73 0.17 103 2 SAI TSH

+0.56 TSH TSH 0.33 111 HOT 580PP

Framatome ANP Inc.

1/24/2006 2:38:44 PM Customer Name: San Onofre -

Unit 2 Component: S/G 88 Page 6 of 15 MAI, MCI, MMI, MVI, SAI, SCI, SVI, 0-100%

QUERY: rpc_icodes and_0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 55 81 0.21 140 P3 TWD 16 DBH

-1.56 TEC TEH 43 HOT 600UL 55 91 0.29 64 P3 TWD 12 DBH

-1.72 TEC TEH 42 HOT 600UL 55 93 0.69 125 P3 TWD 25 DBH

-1.75 STH TEC 2

COLD 600UL 55 95 0.50 170 P3 TWD 19 DBC

+1.30 TEC TEH 42 HOT 600UL 55 97 0.42 168 P3 TWD 26 DBH

+1.37 TEC TEH 43 HOT 600UL 55 135 0.62 35 P1 SCI TSH

-0.09 TSH TSH 0.22 117 HOT 580PP 56 12 0.22 140 P2 TWD 12 VSM

-0.75 TEC TEH 33 HOT 600UL 56 78 0.14 28 P3 TWD 11 DBH

-1.46 TEC TEH 38 HOT 600UL 56 80 0.43 141 P3 TWD 17 DBC

-1.82 TEC TEH 42 HOT 600UL 0.47 81 P3 TWD 18 DBH

-1.90 TEC TEH

.42 HOT 600UL 57 81 0.53 18 2

SAI TSH

-1.39 TSH TSH 0.73 134 HOT 58OPP 0.52 113 P3 TWD 29 DBH

-1.58 TEC TEH 43 HOT 600UL 57 83 1.26 22 P3 TWD 38 DBH

+0.00 STH TEC 4

COLD 600UL 57 97 0.63 17 P3 TWD 22 DBH

+1.03 TEC TEH 42 HOT 600UL 57 109 0.39 78 P2 TWD 16 03H

-1.15 TEH TEC 32 COLD 600UL 57 167 0.44 129 P2 TWD 19 02C

+0.89 TEC TEH 34 HOT 600UL 58_____82____0.63______11____P3____T________27____DBC_____+1____76____ST_______TEC_____4___COLD______________L_

58 82 0.63 11 P3 TWD 27 DBC

+1.76 STH TEC 4

COLD 600UL 58 88 0.43 107 P3 TWD 17 DBC

-1.63 STH TEC 2

COLD 600UL 58 96 0.18 121 P3 TWD 14 DBH

-1.48 TEC TEH 43 HOT 600UL 59 25 0.35 123 P2 TWD 19 VH3

-0.82 TEC TEH 24 HOT 600UL 0.31 164 P2 TWD 17 VH3

+0.74 TEC TEH 24 HOT 600UL 59 27 0.24 125 P2 TWD 14 VH3

-0.90 TEC TEH 25 HOT 600UL 59 95 0.22 61 P3 TWD 17 DBC

+1.92 TEC TEH 43 HOT 600UL 59 99 0.21 126 P2 TWD 16 01H

-0.26 TEC TEH 43 HOT 600UL 59 161 0.33 53 P2 TWD 16 VH3

-0.87 TEC TEH 30 HOT 600UL 60___46__0.25____17__P1____C____T____-0.11________T_________T________0.14________106______HOT__________________

60 46 0.25 17 P1 SCI TSH

-0.11 TSH TSH 0.14 106 HOT 580PP 60 52 0.98 26 P1 SCI TSH

-0.11 TSH TSH 0.26 115 HOT 580PP 60 86 0.29 126 P2 TWD 15 VC3

+1.00 STH TEC 4

COLD 600UL 61 27 0.37 41 P2 TWD 19 VH3

-0.87 TEC TEH 24 HOT 600UL 61 31 0.20 94 P2 TWD 12 VH3

+0.85 TEC TEH 25 HOT 600UL 61 85 0.30 174 P3 TWD 13 DBC

+1.88 TEC TEH 42 HOT 600UL 61 125 0.32 125 P2 TWD 13 VC3

-0.10 TEH TEC 34 COLD 600UL 61 167 0.22 108 P2 TWD 11 02C

+0.96 TEC TEH 34 HOT 600UL 62 24 0.24 133 P2 TWD 14 VH3

+0.78 TEC TEH 24 HOT 600UL 62 54 0.44 21 P1 SCI TSH

-0.09 TSH TSH 0.21 119 HOT 58OPP 62 82 0.57 17 2

SAI TSH

-1.20 TSH TSH 0.20 134 HOT 580PP 62 104 0.45 27 P1 SCI TSH

-2.36 TSH TSH 0.17 96 HOT 580PP 63 11 0.34 100 P2 TWD 17 VH3

-0.78 TEC TEH 33 HOT 600UL 63___49__0.24___126___P___SC____TSH__-0.01________TS________TS_______0.43________115______HOT__________________

63 49 0.24 126 P1 SCI TSH

-0.01 TSH TSH 0.43 115 HOT 580PP

Framatome ANP Inc.

1/24/2006 2:38:44 PM Customer Name: San Onofre -

Unit 2 Component: S/G 88 Page 7 of 15 MAI, MCI, MMI, MVI, SAI, SCI, SVI, 0-100%

QUERY: rpc_icodes and_0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 63 77 0.14 113 2 SAI TSH

+0.86 TSH TSH 0.20 131 HOT 580PP 64 80 0.36 97 P3 TWD 14 DBH

+1.21 TEC TEH 42 HOT 600UL 64 154 0.30 103 P2 TWD 15 VH3

-1.01 TEC TEH 22 HOT 600UL 65 81 0.15 121 P3 TWD 12 DBC

-1.49 TEC TEH 43 HOT 600UL 65 91 0.26 65 P2 TWD 13 VH3

+0.82 TEC TEH 42 HOT 600UL 65 97 0.24 93 P2 TWD 17 02H

-1.19 TEC TEH 43 HOT 600UL 66__48__0.56__121__P2__T____24______-0.79__________.TEH________TEC________43_______COLD______________________L_

66 48 0.56 121 P2 TWD 24 VSM

-0.79 TEH TEC 43 COLD 600UL 0.32 129 P2 TWD 16 VSM

+0.90 TEH TEC 43 COLD 600UL 67 81 0.46 121 P3 TWD 18 DBC

-1.34 TEC TEH 42 HOT 600UL 67 85 0.62 97 P3 TWD 31 DBC

-1.69 TEC TEH 43 HOT 600UL 67 87 0.34 71 P3 TWD 14 DBH

+1.32 TEC TEH 42 HOT 600UL 0.19 116 P3 TWD 8 DBH

-1.62 TEC TEH 42 HOT 600UL 67 97 0.38 53 P2 TWD 18 02H

-1.25 TEC TEH 42 HOT 600UL 67 109 0.26 99 P2 TWD 13 VSM

+0.81 STH TEC 50 COLD 600UL 67 127 0.59 26 P1 SCI TSH

-0.08 TSH TSH 0.19 108 HOT 580PP 67 165 0.69 102 P2 TWD 26 VH3

-0.86 TEC TEH 34 HOT 600UL 68 100 0.18 109 2 SAI TSH

+2.53 TSH TSH 0.24 139 HOT 580PP 68 108 0.40 73 P1 SCI TSH

+0.05 TSH TSH 0.60 96 HOT 580PP 68 146 0.51 95 P2 TWD 22 VC3

-0.97 TEC TEH 17 HOT 600UL 68 158 0.29 93 P2 TWD 15 VH3

-0.87 TEC TEH 30 HOT 600UL 69__13__0.32___85__P2__TWO__18_______-0.89___________T_____C_____TE_________33__________OT___________________L_

69 13 0.32 85 P2 TWD 18 VH3

-0.89 TEC TEH 33 HOT 600UL 69 15 0.48 105 P2 TWD 22 VH3

-0.93 TEC TEH 33 HOT 600UL 69 85 0.18 144 P3 TWD 8 DBC

-1.69 TEC TEH 42 HOT 600UL 69 93 0.48 13 2

MAI TSH

-2.59 TSH TSH 0.17 136 HOT 580PP 0.84 20 2

SAI TSH

-3.88 TSH TSH 0.18 136 HOT 580PP 69 103 0.54 23 P1 SCI TSH

-9.63 TSH TSH 0.17 96 HOT 580PP 69 157 0.16 82 2 SAI 0H

-0.20 08H 08H 0.59 194 HOT 580PP 70 16 0.44 92 P2 TWD 21 VH3

+0.82 TEC TEH 29 HOT 600UL 70 22 0.42 88 P2 TWD 21 06H

+0.80 TEC TEH 28 HOT 600UL 0.22 115 2 SAI 06H

+0.86 06H 06H 0.16 211 HOT 580PP 70 70 0.31 16 P1 SCI TSH

-0.10 TSH TSH 0.18 111 HOT 580PP 70 76 0.27 25 P1 SCI TSH

-0.04 TSH TSH 0.18 130 HOT 58OPP 70 82 0.20 133 P3 TWD 15 DBC

+1.73 TEC TEH 43 HOT 600UL 70 86 0.26 41 P3 TWD 11 DBH

-1.40 TEC TEH 42 HOT 600UL 70 92 0.23 103 P2 TWD 11 VSM

-0.82 TEC TEH 42 HOT 600UL 71 13 0.46 122 P2 TWD 22 VH3

-0.81 TEC TEH 32 HOT 600UL 71 35 0.28 37 P2 TWD 15 O1H

+0.97 TEC TEH 19 HOT 600UL 71 101 0.17 134 P1 SCI TSH

-0.04 TSH TSH 0.20 139 HOT 580PP 72 22 0.14 93 2

SAI 06H

+0.17 06H 06H 0.17 211 HOT 580PP 0.15 87 2

SAI 06H

+0.75 06H 06H 0.15 211 HOT 58OPP 72____66____0.14______85____P1______C____TSR_____+0.00_______TSR_____TSR____0.20______122_______OT_____________

72 66 0.14 85 P1 SCI TSH

+0.00 TSH TSH 0.20 122 HOT 580PP

Framatome ANP Inc.

1/24/2006 2:38:44 PM Customer Name: San Onofre -

Unit 2 Component: S/G 88 Page 8 of 15 MAI, MCI, MMI, MVI, SAI, SCI, SVI, 0-100%

QUERY: rpc icodes and_0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE


_===-======-e==-===-e==-===-=================:=======-===-====-e======--==-----=====-========-=============

72 70 0.36 109 P2 TWD 15 VC3

-0.73 TEH TEC 36 COLD 600UL 72 90 0.49 117 P2 TWD 21 VSM

+0.77 TEC TEH 42 HOT 600UL 0.25 102 P2 TWD 12 VSM

-0.85 TEC TEH 42 HOT 600UL 72 96 0.19 109 2 SAI TSH

+0.26 TSH TSH 0.17 134 HOT 580PP 72 156 0.15 120 2 SAI 08H

+0.18 08H 08H 0.42 194 HOT 580PP 73 115 0.43 21 P1 SCI TSH

-0.10 TSH TSH 0.17 101 HOT 58OPP 73 133 0.29 115 P2 TWD 20 VH3

+0.72 TEC TEH 12 HOT 600UL 74_____82____0.59______133_____P2____TWD_____31____VSM_____+0.85_______TEC_____TE______43____HOT_______________

74 82 0.59 133 P2 TWD 31 VSM

+0.85 TEC TEH 43 HOT 600UL 0.30 139 P2 TWD 20 VSM

-0.85 TEC TEH 43 HOT 600UL 74 96 0.21 114 2 SAI TSH

+0.20 TSH TSH 0.20 136 HOT 58OPP 0.19 109 2 SAI TSH

+0.46 TSH TSH 0.17 136 HOT 580PP 74 138 0.25 139 P2 TWD 18 VH3

-0.85 TEC TEH 12 HOT 600UL 0.39 97 2

SAI VH3

+0.10 VH3 VH3 0.40 132 COLD 560P2 74 148 0.15 106 P2 TWD 12 VH3

-0.92 TEC TEH 21 HOT 600UL 75 77_0.81_31_P1_SC__TS__+0.01_TSHT___0.51_130_HOT____PP 75 77 0.81 31 P1 SCI TSH

+0.01 TSH TSH 0.51 130 HOT 580PP 75 81 0.17 24 P2 SCI TSH

-0.21 TSH TSH 0.22 134 HOT 580PP 75 141 0.17 135 P2 TWD 14 VH3

-0.92 TEC TEH 18 HOT 600UL 75 157 0.27 99 P2 TWD 14 VH3

-0.81 TEC TEH 30 HOT

.600UL 76 84 0.26 112 P2 TWD 13 VH3

+0.84 TEC TEH 42 HOT 600UL 0.31 90 P2 TWD 15 VH3

-0.86 TEC TEH 42 HOT 600UL 76 86 0.19 23 P3 TWD 15 DBC

+2.15 TEC TEH 43 HOT 600UL 76 88 0.36 72 P2 TWD 17 03H

-1.24 TEC TEH 42 HOT 600UL 76 96 0.19 124 P1 SCI TSH

+0.02 TSH TSH 0.29 134 HOT 580PP 76 100 0.19 154 P2 TWD 14 VC3

-0.75 TEC TEH 43 HOT 600UL 76 112 0.35 95 P2 TWD 15 01H

+0.90 TEH TEC 32 COLD 600UL 76 134 0.40 128 P2 TWD 19 VH3

+0.69 TEC TEH 11 HOT 600UL 77 31 0.33 136 P2 TWD 17 VSM

+0.74 TEC TEH 25 HOT 600UL 0.21 117 P2 TWD 12 VSM

+0.23 TEC TEH 25 HOT 600UL 77 33 0.43 71 P2 TWD 21 VSM

+0.77 TEC TEH 20 HOT 600UL 77 39 0.25 158 P3 TWD 15 DBC

+1.58 TEC TEH 15 HOT 600UL 77 87 0.74 18 P1 SCI TSH

-0.20 TSH TSH 0.32 134 HOT 580PP 78 22 0.30 28 P3 TWD 16 DBC

-1.80 TEC TEH 28 HOT 600UL 0.56 84 P2 TWD 26 VC3

-0.94 TEC TEH 28 HOT 600UL 78 88 0.34 118 2 SAI TSH

+0.65 TSH TSH 0.19 136 HOT 580PP 78 136 0.31 54 P3 TWD 28 DBH

-2.08 TEC TEH 12 HOT 600UL 78 138 0.12 155 P3 TWD 15 DBC

+1.59 TEC TEH 12 HOT 600UL 78 142 0.25 138 P2 TWD 18 VH3

+0.94 TEC TEH 18 HOT 600UL 78 144 0.35 30 P3 TWD 24 DBC

+1.59 TEC TEH 18 HOT 600UL 78 148 0.33 136 P2 TWD 21 08C

-0.92 TEC TEH 21 HOT 600UL 78 154 0.28 144 P2 TWD 20 VC3

+0.84 TEC TEH 23 HOT 600UL 0.12 169 P2 TWD 9 VC3

-0.78 TEC TEH 23 HOT 600UL 79 15 0.33 15 P3 TWD 17 DBH

+1.49 TEC TEH 32 HOT 600UL

Framatome ANP Inc.

1/24/2006 2:38:44 PM Customer Name: San Onofre -

Unit 2 Component: S/G 88 Page 9 of 15 MAI, MCI, MMI, MVI, SAI, SCI, SVI, 0-100%

< 1 QUERY: rpc icodes and_0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 79 19 0.22 40 P3 TWD 12 DBC

+1.75 TEC TEH 28 HOT 600UL 79 23 0.25 63 P3 TWD 13 DBC

+1.77 TEC TEH 24 HOT 600UL

~~~~~~~~~~~--

79 75 0.45 112 P2 TWD 19 VH3

+0.79 TEH TEC 36 COLD 600UL 79 89 0.26 69 2

SAI 04H

-0.78 04H 04H 0.18 182 HOT 580PP 0.21 148 P2 TWD 11 04H

-0.82 TEC TEH 42 HOT 600UL i

79 93 0.19 132 P2 TWD 10 VSM

+0.74 TEC TEH 42 HOT 600UL 79 143 0.17 131 P3 TWD 6 DBC

-1.42 TEC TEH 17 HOT 600UL 80 80 0.31 96 P1 SCI TSH

+0.14 TSH TSH 0.41 130 HOT 580PP 0.30 95 P2 TWD 15 VSM

-0.82 TEC TEH 37 HOT 600UL 0.19 55 P2 TWD 11 VSM

+0.72 TEC TEH 37 HOT 600UL 80 82 0.27 61 P2 TWD 14 VSM

+0.16 TEC TEH 42 HOT 600UL 80 86 0.11 19 P3 TWD 6 DBC

+1.98 STH TEC 4

COLD 600UL 80 94 0.27 72 P2 TWD 13 VC3

-0.78 TEC TEH 42 HOT 600UL 80 104 0.28 107 P2 TWD 13 VH3

+0.81 STH TEC 50 COLD 600UL 80 112 0.44 146 P2 TWD 18 VSM

-0.76 TEH TEC 32 COLD 600UL 81 23 0.36 31 P3 TWD 20 DBC

+1.54 TEC TEH 15 HOT 600UL 81 75 0.56 23 Pl SCI TSH

-0.04 TSH TSH 0.18 149 HOT 580PP 81 107 0.29 112 P3 TWD 16 DBH

-1.24 TEH TEC 23 COLD 600UL 81 151 0.21 142 P2 TWD 15 VH3

+0.53 TEC TEH 10 HOT 600UL 0.11 43 P2 TWD 9 VH3

-0.21 TEC TEH 10 HOT 600UL 82 24 0.23 129 2 SAI 06H

+0.45 06H 06H 0.3 211 HOT 580PP 82__54__0.78___105__P2_TWO___27____3_-0.73___________TE__________TEC________7_____COLD_______________________L_

82 54 0.78 105 P2 TWD 27 VH3

-0.73 TER TEC 7

COLD 600UL 0.17 172 P2 TWD 7 VH3

+0.94 TEH TEC 7

COLD 600UL 82 56 0.12 14 P3 TWD 5 DBH

-1.84 TEH TEC 7

COLD 600UL 82 106 0.39 22 P1 SCI TSH

+0.00 TSH TSH 0.17 176 HOT 580PP 82 160 0.21 69 P3 TWD 17 DBH

+2.25 TEC TEH 10 HOT 600UL 83 51 0.43 25 P1 SCI TSH

-8.34 TSH TSH 0.18 164 HOT 58OPP 83 151 0.32 64 2

SAI 08H

+0.50 08H 08H 0.19 195 HOT 58OPP 84 48 0.49 97 P2 TWD 18 09C

-0.90 TEH TEC 5

COLD 600UL 85 43 0.35 136 P2 TWD 19 VH2

-0.77 TEC TER 8

HOT 600UL 85 123 0.28 119 2 SAI 09C

+1.07 09C 09C 0.44 99 COLD 58OPP 86 32 0.16 164 P3 TWD 9 DBC

+1.76 TEC TEH 13 HOT 600UL 86___84__0.71____22__P1___SC____T____-0.04________TSH_______TSH______0.19________172______HOT__________________

86 84 0.71 22 P1 SCI TSH

-0.04 TSH TSH 0.19 172 HOT 580PP 0.59 18 P1 SCI TSH

-0.05 TSH TSH 0.19 172 HOT 580PP 86 112 0.41 59 P2 TWD 15 VH2

+0.79 TEH TEC 22 COLD 600UL 86 130 0.33 68 P2 TWD 16 VC2

+0.78 TEC TEH 5

HOT 600UL 87 35 0.29 149 P2 TWD 16 VH2

-0.86 TEC TEH 7

HOT 600UL 87_ 37____0.32_____134____P2___TWO____17___VH2__

+0.75_______TEC________TEH________8_____HOT_________________

87 37 0.32 134 P2 TWD 17 VH2

+0.75 TEC TEH 8

HOT 600UL 0.37 140 P2 TWD 19 VH2

-0.79 TEC TER 8

HOT 600UL 87 125 0.44 151 P2 TWD 20 VH2

-0.84 TEH TEC 27 COLD 600UL 87 149 0.18 96 2 SAI 07H

-0.19 07H 07H 0.54 195 HOT 580PP 0.21 94 2

SAI 07H

+0.67 07H 07H 0.38 195 HOT 58OPP

Framatome ANP Inc.

1/24/2006 2:38:44 PM Customer Name: San Onofre -

Unit 2 Component: S/G 88 Page 10 of 15 MAI, MCI, MMI, MVI, SAI, SCI, SVI, 0-100%

QUERY: rpcicodes and_0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

--====-======-===-,==-=s=-===-_================:=======-===--==-=======-=======-=====-========-_=========

88 34 0.26 104 P2 TWD 14 VH2

-0.89 TEC TEH 8

HOT 600UL 88__48__0.58___114__P2_TWD___20______-0.82___________TE__________TEC________5_____COLD_______________________L_

88 48 0.58 114 P2 TWD 20 VH2

-0.82 TEH TEC 5

COLD 600UL 88 108 0.39 97 P2 TWD 14 VH2

-0.77 TEH TEC 22 COLD 60U 88 150 0.30 12 P2 TWD 20 06H

-0.34 TEC TEH 10 HOT 600UL 89__33__0.34___144__P2_TWD___18___H2_-0.81___________TEC_________TE_________14_______HOT_______________________

89 33 0.34 144 P2 TWD 18 VH2

-0.81 TEC TEH 14 HOT 600UL 89 35 0.38 78 P2 TWD 20 VH2

-0.93 TEC TEH 8

HOT 600UL 0.06 9

P3 TWD 2 DBH

-1.45 TEC TEH 8

HOT 600UL 89 37 0.42 138 P2 TWD 21 VH2

-0.96 TEC TEH 7

HOT 600UL 89 103 0.33 101 P2 TWD 17 VH2

-0.80 TEH TEC 21 COLD 600UL 89 157 0.31 155 P3 TWD 12 DBH

+1.99 TEC TEH 9

HOT 600UL 90 94 0.40 50 P2 TWD 18 09H

-0.17 TEH TEC 20 COLD 600UL 92__26__0.55___93_P2__TWD__25_______-0.95___________.___________________________________________

TECTE_16_HO__

92 26 0.55 93 P2 TWD 25 VH2

-0.95 TEC TEH 16 HOT 600UL 92 36 0.54 91 P2 TWD 26 VH2

-1.03 TEC TEH 8

HOT 600UL 92 56 0.28 135 P2 TWD 14 09H

-0.68 TEH TEC 8

COLD 600UL 92 58 0.14 12 P3 TWD 5 DBH

-1.77 TEH TEC 9

COLD 600UL 92 90 0.43 90 P1 SCI TSH

+0.05 TSH TSH 0.43 175 HOT 580PP 92 112 0.45 18 P1 SCI TSH

-10.34 TSH TSH 0.19 180 HOT 580PP 93____143_____0___40____120_____P2____TWD_____24________2___+0.98_______TEC_____TEH_____10____HOT______________

93 143 0.40 120 P2 TWD 24 VH2

+0.98 TEC TEH 10 HOT 600UL 93 153 0.24 96 P2 TWD 16 03C

+0.96 TEC TEH 10 HOT 600UL 0.31 47 P2 TWD 20 05C

-0.89 TEC TEH 10 HOT 600UL 0.13 109 P2 TWD 10 VC3

-0.90 TEC TEH 10 HOT 600UL 94_____24____0.32______126_____P2____TW______17____________+1.25_______TEC_____TEH_____15____HOT_______________

94 24 0.32 126 P2 TWD 17 VH2

+1.25 TEC TEH 15 HOT 600UL 94 40 0.32 135 P2 TWD 17 VH2

+1.24 TEC TEH 8

HOT 600UL 94 138 0.19 43 P3 TWD 8 DBH

-1.84 TEC TEH 9

HOT 600UL 95 39 0.34 127 P2 TWD 18 VSM

+0.74 TEC TEH 7

HOT 600UL 0.26 122 2 SAI VSM

+0.74 VSM VSM 0.24 122 COLD 560P2 95 89 0.12 34 P1 SCI TSH

-0.01 TSH TSH 0.14 174 HOT 580PP 95 97 0.27 59 P2 TWD 13 VC3

-0.75 TEH TEC 20 COLD 600UL 96 34 0.32 134 P2 TWD 18 VH2

-1.08 TEC TEH 8

HOT 600UL 96 102 0.12 35 P3 TWD 6 DBH

-1.35 TEH TEC 20 COLD 600UL 96 142 0.34 120 P2 TWD 21 VH2

-0.92 TEC TEH 10 HOT 600UL 96 144 0.12 88 2

SAI 08H

-0.22 08H 08H 0.32 195 HOT 580PP 97 35 0.38 150 P2 TWD 20 VH2

-0.97 TEC TEH 8

HOT 600UL 98___76__0.54___19___P1___C____T____-0.10________TSH.______T_________0.14_______173_______HOT__________________

98 76 0.54 19 P1 SCI TSH

-0.10 TSH TSH 0.14 173 HOT 580PP 98 92 0.20 90 PI SCI TSH

+0.00 TSH TSH 0.20 175 HOT 580PP 99 105 0.71 12 2

SAI TSH

-0.22 TSH TSH 0.23 177 HOT 580PP 99 131 0.27 122 P2 TWD 19 VH3

-0.82 TEC TEH 49 HOT 600UL 0.17 159 P2 TWD 13 VH3

+0.74 TEC TEH 49 HOT 600UL 99 149 0.50 102 P2 TWD 22 VH2

+0.84 TEC TEH 9

HOT 600UL 100___100__0.48___15__P_____C___T____-0.04________T_________T________0.20________178______HOT__________________

100 100 0.48 15 P1 SCI TSH

' -0.04 TSH TSH 0.20 178 HOT 580PP

Framatome ANP Inc.

1/24/2006 2:38:44 PM Customer Name: San Onofre -

Unit 2 Component: S/G 88 Page 11 of 15 MAI, MCI, MMI, MVI, SAI, SCI, SVI, 0-100%

QUERY: rpc icodes and_0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 100 142 0.54 119 2 SAI 06H

+0.54 06H 06H 1.04 195 HOT 58OPP 101-----27----0.49------107-----P2----TWD-----23------------+0.81-------TEC-----TEH-----15----HOT--------------

101 27 0.49 107 P2 TWD 23 VH2

+0.81 TEC TEH 15 HOT 600UL 101 29 0.38 143 P2 TWD 19 VH2

+0.82 TEC TEH 13 HOT 600UL 101 77 0.41 101 147 0.44 102 26 0.32 102 100 0.25 104 40 0.49 104 142 0.40 104 148 0.31 105 135 0.34 0.18 106 30 0.29 106 78 0.24 0.24 107 29 0.50 107 33 0.20 107 75 0.38 107 97 0.32 107 125 0.16 108 36 0.27 108 142 0.11 109 113 0.30 110 52 0.17 110 138 0.25 111___37___0.32_

111 37 0.32 83 131 130 11 65 150 87 137 128 130 157 150 16 120 77 134 79 74 144 14 79 134 35 P3 P2__

P2 P3 P3 P2 P2 2---I P2 2

P2 P2 P2 P3 P2 P2 P2 P3 P3 P3 P2 P3 P3 P3 TWD 20 TWD 20 TWD 17 TWD 12 TWD 22 TWD 24 TWD 20 TWD 16 SAI TWD 15 TWD 13 TWD 13 TWD 22 TWD 12 TWD 18 TWD 15 TW_ 8 TWD 14 TWD 10 TWO 16 TWD 8 TWD 17 TWD 18 DBH

+

VSM 06H 4

DBH DBC 4

VH2 VH2 4

08H 08H 06H 4

VC2 VC2

+

DBC

+

09H 09C VH3 DBH DBC

________+_

DBH

+

DBH

+

DBH VC3 DBH

+

+1.32

-0.78

+0.91

-1.64

+2.10

-0.83

+0.59

-0.21

-0.18

+0.82

-0.93

+0.80

+1.40

-0.37 0.31 0.83 1.51 1.77 1.63 1.85 1.34

0. 91 1.10 TEH TEC TEC___TE__

TEC TEH TEH___TEC_

TEC TEH TEH TEC TEC TEH___

TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TE____TEC_

TEC TEH TEC TEH TEH TEC TEH TEC TEC TEC TEC TEH TEC TEH TEH TEC TEH TEC TEC TEH TEC TEH 0.20 16 9

16 20 7

10 10 5

195 13 16 16 13 13 12 20 27 7

10 23 5

10 8

COLD HOT HOT COLD

.___OT____

HOT HOT HOT HOT_______

HOT HOT HOT HOT COLD--____

COLD COLD HOT-___ -

HOT HOT COLD COLD COLD HOT HOT COLD COLD HOT HOT 600UL 600UL 600UL

_________U_____

600UL 600UL 600UIL 600UL 600UL 580PP 600UL 600UL 60OUL

____________L__

600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL

~~~~---

600UL 111 101 0.15 85 P3 TWD 8 DBH

-1.06 TEH TEC 21 COLD 600UL 112 62 0.60 14 P3 TWD 19 DBH

+2.03 TEH TEC 9

COLD 600UL 0.22 68 P3 TWD 8 DBH

-1.50 TEH TEC 9

COLD 600UL 112 116 0.18 112 P2 TWD 11 VH3

-0.87 TEH TEC 25 COLD 600UL 112_____144_____0___73____162_____P_______W_____24______________1___85____TEC_______E_____9___HOT______________

112 144 0.73 162 P3 TWD 24 DBH

+1.85 TEC TEH 9

HOT 600UL 113 37 0.14 137 P3 TWD 8 DBH

+1.68 TEC TEH 7

HOT 600UL 0.27 139 P2 TWD 15 VH2

-0.93 TEC TEH 7

HOT 600UL 113 39 0.30 101 P3 TWD 17 DBH

+1.64 TEC TEH 8

HOT 600UL 113 41 0.35 95 P2 TWD 19 VH2

-0.68 TEC TEH 7

HOT 600UL 113 47 0.26 48 P3 TWD 12 DBH

-1.50 TEH TEC 5

COLD 600UL 114 38 0.22 150 P2 TWD 12 06C

-0.69 TEC TEH 8

HOT 600UL 114 86 0.11 163 P3 TWD 6 DBH

-1.27 TEH TEC 19 COLD

-600UL 114 96 0.30 125 P2 TWD 16 VH3

-0.84 TEH TEC 21 COLD 600UL 114 110 0.35 71 P3 TWD 13 DBH

-1.36 TEH TEC 22 COLD 600UL

Framatome ANP Inc.

1/24/2006 2:38:45 PM Customer Name: San Onofre -

Unit 2 Component: S/G 88 Page 12 of 15 MAI, MCI, MMI, MVI, SAI, SCI, SVI, 0-100%

QUERY: rpcicodes and_0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 115 69 0.39 78 P2 TWD 16 O1H

+0.82 TEH TEC 11 COLD 600UL 115 83 0.30 123 P3 TWD 14 DBH

-1.50 TEH TEC 16 COLD 600UL 115 127 0.28 143 P2 TWD 12 VH1

+0.89 TEH TEC 26 COLD 600UL 115 137 0.28 112 P2 TWD 14 VH2

-0.87 TEC TEH 9

HOT 600UL 0.41 137 P2 TWD 19 VH1

-1.00 TEC TEH 9

HOT 600UL 116 76 0.31 129 P2 TWD 14 VH1

+0.17 TEH TEC 17 COLD 600UL 116 78 0.16 126 P1 SCI TSH

-0.07 TSH TSH 0.45 173 HOT 580PP 116 102 0.42 126 P3 TWD 18 DBH

+0.80 TEH TEC 20 COLD 600UL 117__55__0.74__125___2__TWD__26______-0.75___________TEH_________TEC________7_____COLD____________________UL___

117 55 0.74 125 P2 TWD 26 VH1

-0.75 TEH TEC 7

COLD 600UL 117_____95____0.31______71______3___TWD_____15____DBH_____+1.97_______TEH_____TEC_____21____COLD____________UL_

117 65 0.44 139 P2 TWD 17 VH1

-0.76 TEH TEC 11 COLD 600UL 117 95 0.31 71 P3 TWD 15 DBH

+1.97 TEH TEC 21 COLD 600UL 117 105 0.39 91 P2 TWD 19 VH1

-0.98 TEH TEC 21 COLD 600UL 118 38 0.08 126 P3 TWD 3 DBC

+2.05 TEC TEH 8

HOT 600UL 118 68 0.22 129 P3 TWD 11 DBH

-1.70 TEH TEC 12 COLD 600UL 118 72 0.21 151 P3 TWD 11 DBH

-1.97 TEH TEC 16 COLD 600UL 0.22 61 P3 TWO 11 DBH

+1.80 TEH TEC 16 COLD 600UL 118 88 0.24 145 P3 TWD 14 DBH

-1.72 TEH TEC 19 COLD 600UL 118 90 0.18 27 P3 TWO 11 DBH

-1.72 TEH TEC 19 COLD 600UL 118 116 0.66 128 P2 TWD 24 09H

-0.10 TEH TEC 24 COLD 600UL 119 37 0.08 29 P3 TWD 3 DBC

-2.02 TEC TEH 8

HOT 600UL 0.24 10 P3 TWD 14 DBC

+2.25 TEC TEH 8

HOT 600UL 0.08 124 P2 TWD 3 10C

-1.51 TEC TEH LOCOK 8

HOT 600UL 119 45 0.30 161 P2 TWD 17 VH1

-0.94 TEC TEH 8

HOT 600UL 119 55 0.22 40 P3 TWD 12 DBH

+2.17 TEH TEC 8

COLD 600UL 119 57 0.56 131 P2 TWO 26 VH1

-0.87 TEH TEC 8

COLD 600UL 119 61 0.57 150 P2 TWD 21 VH1

-0.88 TEH TEC 9

COLD 600UL 119 79 0.37 100 P3 TWD 19 DBH

+2.01 TEH TEC 16 COLD 600UL 120___86_0.23___74__P3_TWD___10_D__N_-1.59___________TEN________TEC________18______COLD______________________L_

119 81 0.55 132 P2 TWD 24 VH1

-0.80 TEH TEC 16 COLD 600UL 119 95 0.48 106 P3 TWD 19 DBH

-1.77 TEH TEC 20 COLD 600UL 119 97 0.37 148 P3 TWD 16 DBH

-1.70 TEH TEC 20 COLD 600UL 119 99 0.33 120 P3 TWD 15 DBH

-1.42 TEH TEC 20 COLD 600UL 119 101 0.31 121 P3 TWD 16 DBH

-1.87 TEH TEC 21 COLD 600UL 119 109 0.45 9

P3 TWD 22 DBH

+1.94 TEH TEC 23 COLD 600UL 119 115 0.51 124 P2 TWD 20 VH1

-0.87 TEH TEC 24 COLD 600UL 120 38 0.22 124 P3 TWD 13 DBC

+2.25 TEC TEH 8

HOT 600UL 0.12 106 P3 TWD 6 DBC

-2.23 TEC TEH 8

HOT 600UL 120 42 0.38 136 P2 TWD 20 VH1

-0.81 TEC TEH 8

HOT 600UL 120 66 0.54 109 P3 TWO 20 DBH

-1.59 TEH TEC 11 COLD 600UL 120 74 0.28 104 P2 TWO 12 10H

-1.25 TEH TEC 17 COLD 600UL 120 80 0.23 58 P3 TWD 12 DBH

-1.90 TEH TEC 16 COLD 600UL 120 86 0.23 74 P3 TWD 10 DBH

-1.59 TEH TEC 18 COLD 600UL

Framatome ANP Inc.

1/24/2006 2:38:45 PM Customer Name: San Onofre -

Unit 2 Component: S/G 88 Page 13 of 15 MAI, MCI, MMI, MVI, SAI, SCI, SVI, 0-100%

QUERY:

rpcicodes and_0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 0.40 117 P2 TWD 16 10H

+1.25 TEH TEC 18 COLD 600UL 120 92 0.31 49 P3 TWD 11 DBH

-1.85 TEH TEC 44 COLD 600UL 120 94 0.17 106 P3 TWD 7 DBH

-1.99 TEH TEC 44 COLD 600UL 120 106 0.28 2

P3 TWD 14 DBH

+1.68 TEH TEC 21 COLD 600UL 120 138 0.39 133 P3 TWD 15 DBH

-1.53 TEC TEH 9

HOT 600UL 121 39 0.35 68 P2 TWD 19 03C

-0.91 TEC TEH 8

HOT 600UL 121 67 0.27 135 P3 TWD 11 DBH

-1.73 TEH TEC 11 COLD 600UL 121 69 0.32 25 P2 TWD 13 04H

+0.84 TEH TEC 44 COLD 600UL 121 71 0.18 137 P3 TWD 11 DBH

-1.75 TEH TEC 16 COLD 600UL 121 125 0.49 126 P2 TWD 19 10H

+0.79 TEH TEC 26 COLD 600UL 121 137 0.24 153 P3 TWD 10 DBH

-1.84 TEC TEH 9

HOT 600UL 122_____94____0.22______135_____P3___TW______13____DBH_____+1.84_______TEH____TEC_____19____COLD____________U__

122 94 0.22 135 P3 TWD 13 DBH

+1.87 TEH TEC 19 COLD 600UL 122 96 0.38 127 P3 TWD 19 DBH

+1.76 TEH TEC 21 COLD 600UL 122 112 0.36 39 P2 TWD 13 10H

-1.05 TEH TEC 22 COLD 600UL 122 114 0.39 118 P2 TWD 16 10H

+0.93 TEH TEC 24 COLD 600UL 0.38 142 P3 TWD 15 DBH

+1.75 TEH TEC 24 COLD 600UL 122 124 0.40 130 P3 TWD 18 DBH

+1.56 TEH TEC 27 COLD 600UL 123 45 0.30 152 P2 TWD 17 VH1

-1.24 TEC TEH 7

HOT 600UL 123__65__0.32__128__P3__T____15__DBH_-0.08___________TEH________TEC________12______COLD___________________UL___

123 65 0.32 128 P3 TWD 15 DBH

-0.08 TEH TEC 12 COLD 600UL 124 64 0.38 63 P2 TWD 15 10H

-0.86 TEH TEC 9

COLD 600UL 124 88 0.26 17 P3 TWD 11 DBH

+2.13 TEH TEC 18 COLD 600UL 126_____86____0___39____132_____P3___TWD_____19____________+1____86____TE_____TEC_____19____COLD____________0L_

125 91 0.26 135 P3 TWD 10 DBH

+1.90 TEH TEC 44 COLD 600UL 126 86 0.39 132 P3 TWD 19 DBH

+1.86 TEH TEC 19 COLD 600UL 126 90 0.31 114 P3 TWD 16 DBH

+2.11 TEH TEC 19 COLD 600UL 12 112__0.57_26__3_____20_______1_54_T_______22_COLD______

126 112 0.57 26 P3 TWD 20 DBH

+1.54 TEH TEC 22 COLD 600UL 127 53 127 83 127 101 128___60 128 60 128 68 129 47 12 63__

129 63 129 67 129 75 130 74

0. 62 0.39 0.21 0.45 0.54 0.31 0.83 0.30 0.26 0.74 0.54 0.34 95 P2 146 P3 78 P2 51 P2 137 P2 32 P3 138 P2 100 P2 75 P3 94 P2 156 P2 73 P2 TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD 27 16 12 18 21 13 26 15 14 29 24 17 VH1 DBH VH3 10H lOH DBH VH3 10H DBH VH1 10H 10H

-0.93

-1.87

+0.81

+0.00

-1.22

+2.04

-0.89

-0. 10

-1.81

-0.31

-0.91

-0. 10 TE_ TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TE_ TEC TEH TEC TEH TEC TE_ TEC TEH TEC TEH TEC 8___COLD____

8 COLD 21____COLD__

17 COLD 21 COLD 7

COLD 7

COLD 11 COLD 44 COLD 10 COLD 12 COLD 14 COLD 16 COLD 16 COLD

_60 UL 600UL

_6__0UL 600UL

_6__0UL 600UL

_600UL 600UL 600UL

_600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL z --

s s

- z w

z 130 94 0.77 153 P2 TWD 30 10H

-1.02 TEH TEC 19 COLD 600UL 130 124 1.36 5

2 SAI 06H

+0.11 05H 06H 0.34 245 HOT 58OPP 130 128 0.47 89 P2 TWD 18 VH2

-0.50 TEH TEC 26 COLD 600JL

Framatome ANP Inc.

1/24/2006 2:38:45 PM Customer Name: San Onofre -

Unit 2 Component: S/G 88 Page 14 of 15 MAI, MCI, MMI, MVI, SAI, SCI, SVI, 0-100%

QUERY: rpc icodes and_0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE S==--====-_=====-===-===-===-===-=================:=5-===-===-_===-=======-=======-=====-========-=============

131 77 0.79 29 P3 TWD 26 DBH

+1.99 TEH TEC 30 COLD 600UL 131 83 0.25 71 P3 TWD 11 DBH

-1.85 TEH TEC 30 COLD 600UL 131 89 0.70 119 P2 TWD 24 10H

+0.95 TEH TEC 30 COLD 600UL 131 127 0.45 128 P2 TWD 23 03C

+0.84 TEH TEC 33 COLD 600UL 132 94 0.56 99 P2 TWD 21 10H

+0.93 TEH TEC 30 COLD 600UL 133_____75

____0.35 ______99____P3____T__D___18___-DBH_____+1._____9_-_TEN____TEC_____31

____COLD ____________UL_

133 75 0.35 99 P3 TWD 18 DBH

+1.59 TEH TEC 31 COLD 600UL 133 83 0.32 161 P2 TWD 17 10H

-1.09 TEH TEC 31 COLD 600UL 133 115 0.55 130 P2 TWD 26 10H

+0.87 TEH TEC 33 COLD 600UL 134 68 0.21 149 P2 TWD2 7

10H

-0.72 TEH TEC 29 COLD 600UL 134 84 0.21 161 P2 TWD 10 10H

-1.11 TEH TEC 30 COLD 600UL 134 86 0.92 140 P2 TWD 29 10H

-0.99 TEH TEC 30 COLD 600UL 134 100 0.43 161 P2 TWD 17 10H

+0.86 TEH TEC 30 COLD 600UL 135 85 0.22 99 2

SAI 06H

-0.10 066H 0.28 212 HOT 580PP 135 87 0.74 150 P2 TWD 25 10H

-1.09 TEH TEC 30 COLD 600UL 135 93 0.36 104 P2 TWD 15 10H

+0.95 TEH TEC 30 COLD 600UL 135 97 0.28 104 P2 TWD 12 10H

+0.91 TEH TEC 30 COLD 600UL 136 74 0.35 81 P2 TWD 15 10H

-0.99 TEH TEC 30 COLD 600UL 136 86 0.21 132 P2 TWD2 10H

-1.06 TEH TEC 31 COLD 600UL 137 91 0.44 158 P2 TWD 21 10H

-1.14 TEH TEC 31 COLD 600UL 137 119 0.36 75 P2 TWD 20 01C

-0.93 TEH TEC 33 COLD 600UL 139 105 0.58 103 P2 TWD 21 10H

+0.88 TEH TEC 30 COLD 600UL 140 76 0.14 33 P3 TWD 9 DBH

-1.89 TEH TEC 31 COLD 600UL 140 88 0.26 74 P3 TWD 11 DBH

+2.11 TEH TEC 30 COLD 600UL 141 63 0.44 27 P3 TWD 17 DBC

+1.77 TEH TEC 28 COLD 600UL 0.21 9

P3 TWD 8 DBC

-2.12 TEH TEC 28 COLD 600UL 141 65 0.30 130 P2 TWD 16 08C

+0.82 TEH TEC 29 COLD 600UL 141 67 0.63 110 P2 TWD 27 VC1

+0.86 TEH TEC 29 COLD 600UL 141 77 0.29 97 P3 TWD 16 DBC

+1.93 TEH TEC 31 COLD 600UL 143___89_0.24___47__P3_T_____11_DEN__-1.75___________TEN________TEC________30______COLD___________________UL___

142 66 0.23 38 P3 TWD 13 DBC

+1.34 TEH TEC 29 COLD 600UL 142 68 0.22 113 P2 TWD 12 10H

-0.23 TEH TEC 29 COLD 600UL 142 84 0.41 116 P3 TWD 17 DBC.

+1.32 TEH TEC 30 COLD 600UL 142 86 0.27 100 P3 TWD 12 DBH

+1.91 TEH TEC 30 COLD 600UL 142 90 0.27 119 P3 TWD 12 DBH

+2.04 TEH TEC 30 COLD 600UL 142 98 0.29 13 P3 TWD 16 DBC

+1.85 TEH TEC 31 COLD 600UL 142 104 0.38 23 P3 TWD 16 DBH

+1.71 TEH TEC 30 COLD 600UL 142 110 0.45 41 P3 TWD 22 DBH

+1.98 TEH TEC 31 COLD 600UL 143 83 0.30 71 P3 TWD 16 DBC

+1.70 TEH TEC 31 COLD 600UL 143 89 0.24 47 P3 TWD 11 DBH

-1.75 TEH TEC 30 COLD 600UL

Framatome ANP Inc.

1/24/2006 2:38:45 PM Customer Name: San Onofre -

Unit 2 Component: S/G 88 Page 15 of 15 MAI, MCI, MMI, MVI, SAI, SCI, SVI, 0-100%

QUERY: rpc icodes and_0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 143 109 0.19 133 P3 TWD 11 DBH

-1.84 TEH TEC 31 COLD 600UL 144 76 0.34 151 P2 TWD 18 VC2

+0.90 TEH TEC 31 COLD 600UL 144 78 0.41 114 P3 TWD 20 DBC

-1.92 TEH TEC 31 COLD 600UL 144 80 0.51 119 P3 TWD 19 DBH

+1.98 TEH TEC 30 COLD 600UL 144 84 0.69 106 P3 TWD 28 DBC

+1.70 TEH TEC 31 COLD 600UL 144 86 0.28 129 P3 TWD 12 DBH

+2.02 TEH TEC 30 COLD 600UL 144_____90____0.59______39____P3____TWD_____26____DEC_____+1.77_______TEH_____TEC_____31____COLD____________UL_

144 90 0.59 39 P3 TWD 26 DBC

+1.77 TEH TEC 31 COLD 600UL 144 96 0.41 118 P3 TWD 17 DBH

+1.97 TEH TEC 30 COLD 600UL 0.55 91 P3 TWD 20 DBC

+1.46 TEH TEC 30 COLD 600UL 145 75 0.46 139 P2 TWD 22 VHl

-0.82 TEH TEC 31 COLD 600UL 0.40 58 P3 TWD 20 DBC

+1.89 TEH TEC 31 COLD 600UL 0.54 74 P3 TWD 25 DBH

+1.99 TEH TEC 31 COLD 600UL 145 79 0.36 119 P3 TWD 18 DBC

+1.56 TEH TEC 31 COLD 600UL 145 87 0.30 69 P3 TWD 13 DBC

-2.01 TEH TEC 30 COLD 600UL 0.29 51 P3 TWD 12 DBC

+1.52 TEH TEC 30 COLD 600UL 145 89 0.24 118 P3 TWD 14 DBH

-1.96 TEH TEC 31 COLD 600UL 0.32 122 P2 TWD 17 VC1

+0.86 TEH TEC 31 COLD 600UL 146 80 0.54 56 P3 TWD 25 DBC

+1.74 TEH TEC 31 COLD 600UL 146 82 0.14 34 P2 TWD 9 03H

-0.17 TEH TEC 31 COLD 600UL 146 94 0.19 149 P2 TWD 11 02H

+0.88 TEH TEC 31 COLD 600UL 147 91 0.42 144 P2 TWD 20 VC1

-0.83 TEH TEC 31 COLD 600UL Total Tubes

474 Total Records: 551

Inservice Inspection of Steam Generator Tubes Attachment Special Report Page 1 of 17 Appendix 4 Tube Inspection Summary Steam Generator E-089

I Framatome ANP Inc.

01/24/06 17:39:07 Customer Name: San Onofre -

Unit 2 Component: S/G 89 Page 2 of 17 MAI,MCI,MMI,MVI,SAI,SCI,SVI,0-100%TWD QUERY: rpc icodes-and 0-100%twd ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 3

131 0.53 19 P1 SCI TSH

-1.82 TSH TSH 0.17 85 HOT 580PP 8__140___0.___3__26__P1____C____T____-6.23_________T________TSH_______0.20________85______HOT__________________

8 140 0.33 26 P1 SCI TSH

-6.23 TSH TSH 0.20 85 HOT 580PP 8

156 0.55 24 P1 SCI TSH

-0.06 TSH TSH 0.20 80 HOT 580PP 9

45 0.55 18 2

SAI TSH

-15.04 TSH TSH 0.20 64 HOT 580PP 0.35 13 2

SAI TSH

-14.82 TSH TSH 0.14 64 HOT 58OPP 10 142 0.72 25 P1 SCI TSH

-6.14 TSH TSH 0.20 85 HOT 580PP 11 51 0.14 85 P3 TWD 6 DBH

-1.66 TEH TEC 28 COLD 600UL 11 _____________________________________________________

53__0.18_93_2_________+0_75__________0.30_172_HOT______

11 53 0.18 93 2

SAI 04H

+0.75 04H 04H 0.30 172 HOT 580PP 11 57 0.15 116 2 SAI 06H

+0.05 06H 06H 0.26 173 HOT 580PP 11 61 0.24 127 P1 SCI TSH

+0.09 TSH TSH 0.19 132 HOT 580PP 12 38 0.33 30 P1 SCI TSH

-0.11 TSH TSH 0.19 79 HOT 580PP 12 116 0.43 24 2

SAI TSH

-1.13 TSH TSH 0.18 62 HOT 580PP 13 37 0.26 25 P3 TWD 10 DBC

+0.06 TEC TEH 23 HOT 600UL 13 115 0.23 106 2 SAI 06H

+0.91 06H 06H 0.27 190 HOT 580PP 14 16 0.81 21 2

SAI TSH

-10.51 TSH TSH 0.2 91 HOT 580PP 14 140 0.18 111 P1 SCI TSH

+0.16 TSH TSH 0.19 108 HOT 580PP 17 27 0.20 41 P3 TWD 8 DBC

+1.16 TEC TEH 29 HOT 600UL 18 46 0.39 83 P2 TWD 15 01H

+0.94 TEC TEH 22 HOT 600UL 18 144 0.32 151 P3 TWD 13 DBH

+1.15 TEC TEH 20 HOT 600UL 19 109 0.21 134 P3 TWD 13 DBC

+1.98 TEH TEC 31 COLD 600UL 19 173 0.25 137 P2 TWD 12 VSM

+0.81 TEC TEH 28 HOT 600UL 20 18 0.62 128 P2 TWD 24 VSM

-0.09 TEC TEH 40 HOT 600UL 20 42 0.35 77 2

SAI 05H

+0.28 05H 05H 0.22 162 HOT 580PP 20 58 0.20 111 P1 SCI TSH

+0.15 TSH TSH 0.21 132 HOT 580PP 20 108 0.11 160 P3 TWD 4 DBC

+1.01 TEH TEC 32 COLD 600UL 20 122 0.49 23 P1 SCI TSH

-0.11 TSH TSH 0.18 67 HOT 580PP 0.26 65 2

SAI 07C

-0.36 07C 07C 0.18 97 COLD 580PP 21 67 0.44 123 P2 TWD 17 VSM

+0.91 TEH TEC 30 COLD 600UL 22 2

0.50 139 P2 TWD 21 VSM

-0.91 TEC TEH 44 HOT 600UL 22 54 0.26 129 2 SAI 06H

+0.93 06H 06H 0.29 172 HOT 580PP 22 118 0.42 132 P2 TWD 18 07H

+0.94 TEH TEC 33 COLD 600UL 23 23 0.34 68 P2 TWD 17 07H

+0.59 TEH TEC 44 COLD 600UL 23 59 0.32 107 P2 TWD 14 O1H

+0.85 TEH TEC 28 COLD 600UL 23 115 0.30 153 P2 TWD 16 VSM

+0.93 TEH TEC 31 COLD 600UL 24 18 0.25 96 P2 TWD 12 VSM

-0.92 TEC TEH 40 HOT 600UL 24 126 0.57 100 2 SAI 07C

+0.70 07C 07C 1.23 97 COLD 580PP 24 154 0.23 89 P2 TWD 12 VSM

+0.04 TEC TEH 25 HOT 600UL 25 53 0.29 104 P1 SCI TSH

+0.10 TSH TSH 0.28 127 HOT 580PP 27___137__0.86____19__P1__SC____TS___-0.01________TSH_______T________0.30________108______HOT__________________

27 137 0.86 19 P1 SCI TSH

-0.01 TSH TSH 0.30 108 HOT 580PP

Framatome ANP Inc.

01/24/06 17:39:07 Customer Name: San Onofre -

Unit 2 Component: S/G 89 Page 3 of 17 MAI,MCI,MMI,MVI,SAI,SCI,SVI,0-100%TWD QUERY: rpcicodesand_0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 29 45 0.33 85 2

SAI 05H

-0.72 05H 05H 0.32 163 HOT 58OPP 29 53 0.27 88 P1 SCI TSH

+0.10 TSH TSH 0.26 127 HOT 580PP 30 70 0.27 141 P3 TWD 13 DBC

-1.98 TEH TEC 30 COLD 600UL 30 110 0.19 114 2 SAI TSH

+0.39 TSH TSH 0.18 62 HOT 580PP 31 71 0.25 124 P3 TWD 12 DBC

-2.19 TEH TEC 30 COLD 600UL 0.55 77 P3 TWD 22 DBH

-1.64 TEH TEC 30 COLD 600UL 0.35 53 P3 TWD 16 DBC

+1.97 TEH TEC 30 COLD 600UL 32 140 0.22 74 P2 TWD 12 VSM

-0.93 TEC TEH 19 HOT 600UL 34____60____0.16______117______1___SC______T______+0.08_______T___H__TS______0.22______132____HOT______________

34 60 0.16 117 P1 SCI TSH

+0.08 TSH TSH 0.22 132 HOT 580PP 0.14 127 P1 SCI TSH

+0.10 TSH TSH 0.14 132 HOT 580PP 0.16 97 P1 SCI TSH

+0.01 TSH TSH 0.19 132 HOT 580PP 0.48 12 2

SAI TSH

-2.15 TSH TSH 0.14 132 HOT 580PP 35____51____0.26______82____2___S_______T_______+0._____1___TSH_____TSH_____0.38______128_____HOT______________

35 51 0.26 82 2 SAI TSH

+0.81 TSH TSH 0.38 128 HOT 580PP 36 50 0.10 83 P1 SCI TSH

+0.14 TSH TSH 0.19 128 HOT 580PP 36 104 0.21 85 P3 TWD 11 DBC

-1.95 TER TEC 29 COLD 600UL 36 114 0.33 108 P2 TWD 15 02H

+0.88 TEH TEC 33 COLD 600UL 37 101 0.28 30 P3 TWD 15 DBC

+1.89 TEC TEN 35 HOT 600UL 37 103 0.43 45 P3 TWD 20 DBH

-1.49 TEH TEC 29 COLD 600UL 37 111 0.27 17 2

SAI TSH

-2.16 TSH TSH 0.14 61 HOT 580PP 38__4__0.34____67__P2__TW___15_____C_-0.93___________T_____C_____TEH________44_______HO________________________

38 4

0.34

.67 P2 TWD 15 02C

-0.93 TEC TER 44 HOT 600UL 0.30 60 P2 TWD 14 01C

+0.15 TEC TEH 44 HOT 600UL 38 20 0.27 133 P3 TWD 11 DBH

+0.94 TEC TEH 39 HOT 600UL 38 128 0.35 101 P1 SCI TSH

+0.07 TSH TSH 0.40 55 HOT 580PP 38 156 0.38 100 P2 TWD 17 03H

-0.89 TEC TEH 26 HOT 600UL 39 101 0.22 84 P3 TWD 11 DBC

-1.91 TEC TEH 34 HOT 600UL 0.22 48 P3 TWD 11 DBC

+2.06 TEC TEH 34 HOT 600UL 40 74 0.52 136 P3 TWD 16 DBC

-1.63 STH TEC 55 COLD 600UL 40 140 0.22 39 P2 TWD 12 VSM

-0.89 TEC TEH 19 HOT 600UL 41 49 0.20 132 2 SAI 02H

-0.20 02H 02H 0.36 172 HOT 580PP 0.33 119 P2 TWD 15 02H

-0.24 TEH TEC 25 COLD 600UL 41 63 0.40 72 P2 TWD 18 02H

+0.81 TEH TEC 29 COLD 600UL 41 73 0.36 118 P3 TWD 16 DBC

-1.79 TEN TEC 30 COLD 600UL 41 75 0.44 121 P3 TWD 20 DBC

+1.83 TEH TEC 29 COLD 600UL 0.20 13 P3 TWD 11 DBC

-2.20 TEH TEC 29 COLD 600UL 41 101 0.44 60 P3 TWD 21 DBC

+1.91 TEC TEH 35 HOT 600UL 41 103 0.28 125 P2 TWD 12 VSM

+0.91 STH TEC 48 COLD 600UL 41 143 0.27 79 P2 TWD 14 VSM

+0.79 TEC TEN 19 HOT 600UL 42 168 0.55 140 P2 TWD 22 VSM

+1.05 TEC TEH 27 HOT 600UL 42 170 0.77 128 P2 TWD 28 VSM

-0.43 TEC TEN 28 HOT 600UL 43 101 0.75 93 P3 TWD 27 DBC

+1.65 TEC TEH 34 HOT 600UL 44 18 0.19 48 P2 TWD 10 VSM

+0.54 TEC TEN 40 HOT 600UL 0.41 117 P2 TWD 18 VSM

-0.93 TEC TEH 40 HOT 600UL 44____50____0.23______145_____P3____TWO_____12____DEC_____+2.19_______TEN_____TEC_____25____COLD_______________

44 50 0.23 145 P3 TWD 12 DBC

+2.19 TER TEC 25 COLD 600UL

Framatome ANP Inc.

01/24/06 17:39:07 Customer Name: San Onofre -

Unit 2 Component: S/G 89 Page 4 of 17 MAI,MCI,MMI,MVI,SAI,SCI,SVI,0-100%TWD QUERY: rpc icodes and_0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 44 74 0.55 61 P3 TWD 23 DBC

-2.00 TEH TEC 29 COLD 600UL 0.28 54 P3 TWD 14 DBC

+1.78 TEH TEC 29 COLD 600UL 44 104 0.44 111 P2 TWD 19 VSM

+0.81 TEH TEC 29 COLD 600UL 0.06 141 P2 TWD 3 VSM

-0.42 TEH TEC 29 COLD 600UL 44 112 0.41 139 P2 TWD 18 VSM

-0.76 TEH TEC 33 COLD 600UL 45 103 0.17 127 P2 TWD 9 VSM

+0.00 TEH TEC 29 COLD 600UL 0.54 141 P2 TWD 22 VSM

+0.88 TEH TEC 29 COLD 600UL 0.32 110 P2 TWD 15 VSM

-0.73 TEH TEC 29 COLD 600UL 45 145 0.27 75 P2 TWD 14 VSM

-0.90 TEC TEH 19 HOT 600UL 45 147 0.27 140 P3 TWD 11 DBH

+1.95 TEC TEH 20 HOT 600UL 0.32 111 2 SAI DBH

+2.05 DBH DBH 0.27 203 HOT 560P2 46__52__0.27___117__P2_TWD___13______-0.88___________TEN________TEC________28______COLD___________________UL___

46 52 0.27 117 P2 TWD 13 VSM

-0.88 TEH TEC 28 COLD 600UL 0.27 155 P2 TWD 13 VSM

+0.80 TEH TEC 28 COLD 600UL 46 104 0.79 97 P2 TWD 25 VSM

-0.69 TEH TEC 30 COLD 600UL 0.26 60 P2 TWD 11 VSM

+0.24 TEH TEC 30 COLD 600UL 46 128 0.33 140 P2 TWD 14 VSM

-0.90 TEH TEC 35 COLD 600UL 46 156 0.10 172 P2 TWD 5 VSM

+0.70 TEC TEH 26 HOT 600UL 0.56 106 P2 TWD 23 VSM

-1.01 TEC TEH 26 HOT 600UL 46 162 0.32 78 P2 TWD 15 VSM

+0.88 TEC TEH 26 HOT 600UL 46 170 0.37 83 P3 TWD 17 DBC

+1.55 TEC TEH 28 HOT 600UL 47 29 0.51 23 P3 TWD 22 DBH

-1.78 TEH TEC 44 COLD 600UL 47 33 0.52 67 P3 TWD 21 DBH

+1.70 TEC TEH 24 HOT 600UL 47 121 0.23 159 P2 TWD 13 VSM

-0.81 TEH TEC 34 COLD 600UL 48 6

0.47 90 P2 TWD 20 08C

-1.72 TEC TEH LOCOK 44 HOT 600UL 48 8

0.33 131 P2 TWD 15 02C

+0.90 TEC TEH 44 HOT 600UL 48 34 0.25 37 P2 TWD 11 VSM

-0.76 TEC TEH 23 HOT 600UL 48 66 0.99 153 P2 TWD 29 VSM

-0.91 TEH TEC 30 COLD 600UL 48__74__0.40___49_P3__T__D_14__D__C_-1.97___________ST_________TEC________55______COLD________________________

48 74 0.40 49 P3 TWD 14 DBC

-1.97 STH TEC 55 COLD 600UL 0.13 69 P3 TWD 5 DBC

+1.46 STH TEC 55 COLD 600UL 48 100 0.53 49 P3 TWD 22 DBC

+2.04 TEC TEH 34 HOT 600UL 48 118 0.49 69 P2 TWD 20 04H

-1.10 TEH TEC 33 COLD 600UL 48 158 0.71 155 P2 TWD 27 VSM

-0.63 TEC TEH 25 HOT 600UL 0.13 168 P2 TWD 7 VSM

+0.91 TEC TEH 25 HOT 600UL 49 39 0.25 143 P2 TWD 11 VSM

-0.82 TEC TEH 24 HOT 600UL 49 53 0.48 114 P2 TWD 21 08C

-1.43 TEH TEC LOCOK 27 COLD 600UL 49 65 0.34 108 P2 TWD 14 VSM

-0.80 TEH TEC 30 COLD 600UL 49 75 0.26 142 P3 TWD 13 DBC

-2.24 TEH TEC 29 COLD 600UL 49 103 0.31 126 P2 TWD 15 VSM

-0.87 TEH TEC 29 COLD 600UL 49 145 0.54 73 P2 TWD 24 08H

-1.19 TEC TEH 19 HOT 600UL 49 159 0.57 113 P2 TWD 23 VSM

+0.72 TEC TEH 26 NOT 600UL 0.19 70 P2 TWD 10 VSM

-0.21 TEC TEH 26 HOT 600UL 50 16 0.15 14 P2 TWD 7 08H

+1.07 TEC TEH 41 HOT 600UL 50 44 0.29 69 P2 TWD 12 VSM

-0.91 TEC TEH 22 HOT 600UL 50__48__0.30__120__P3__TWD__14__DEN_-1.66___________TEN________TEC________25_______COLD___________________U____

50 48 0.30 120 P3 TWD 14 DBH

-1.66 TEH TEC 25 COLD 600UL

Framatome ANP Inc.

01/24/06 17:39:07 Customer Name: San Onofre -

Unit 2 Component: S/G 89 Page 5 of 17 MAI,MCI,MMI,MVI,SAI,SCI,SVI,0-100%TWD QUERY: rpc_icodes and_0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 50 64 0.16 119 2 SAI 08C

+1.48 08C 08C 0.18 LOCOK 99 COLD 580PP 50_____74____0.31______36____P3____T___D___14____DEC_____+2.15_______TEH_____TEC_____30____COLD____________UL__

50 74 0.31 36 P3 TWD 14 DBC

+2.15 TEH TEC 30 COLD 600UL 0.26 74 P3 TWD 12 DBC

-2.17 TER TEC 30 COLD 600UL 50 76 0.54 123 P3 TWD 21 DBC

-1.65 TEC TEH 28 HOT 600UL 50 78 0.49 107 P3 TWD 19 DBC

+1.67 STH TEC 4

COLD 600UL 0.31 112 P3 TWD 13 DBC

-2.04 STH TEC 4

COLD 600UL 50 100 0.47 122 P3 TWD 23 VSM

+0.10 TEC TEH 35 HOT 600UL 51 75 0.64 73 P3 TWD 20 DBC

-1.10 STH TEC 55 COLD 600UL 51 153 0.60 130 P3 TWD 24 DBC

+0.62 TEC TEH 26 HOT 600UL 52 12 0.31 98 2

SAI VH3

+0.10 VH3 VH3 0.41 205 HOT 560P2 52 76 0.45 83 P3 TWD 18 DBC

-1.67 TEC TEH 27 HOT 600UL 52 __80__

0.60___ 96_ P3_____

D_ 23__

D__C_

1.66________

___TEC_____

____TE ______

____27_____

HOT______

52 80 0.60 96 P3 TWD 23 DBC

-1.66 TEC TER 27 HOT 600UL 52__84__0.27___127__P3_T__D__12_DEC__-1.92___________TEC_________TE_________27_______HOT_______________________

52 84 0.27 127 P3 TWD 12 DBC

-1.92 TEC TEH 27 HOT 600UL 0.28 141 P3 TWD 12 DBC

+1.75 TEC TER 27 HOT 600UL 0.63 74 P3 TWD 23 DBH

+1.72 TEC TEH 27 HOT 600UL 0.41 131 P3 TWD 17 DBH

-2.10 TEC TEH 27 HOT 600UL 52 96 0.26 24 P3 TWD 12 DBH

-1.74 TEC TEH 30 HOT 600UL 52 160 0.45 27 P2 TWD 20 VH3

-1.05 TEC TEH 25 HOT 600UL 53 29 0.39 117 P2 TWD 15 VH3

+0.68 TEC TEH 29 HOT 600UL 53__77__0.35___119__P3_TWD___15_DEC__-1.67___________TEC_________TE_________27_______HOT_______________________

53 77 0.35 119 P3 TWD 15 DBC

-1.67 TEC TEH 27 HOT 600UL 53 81 0.23 149 P3 TWD 10 DBC

-1.92 TEC TER 27 HOT 600UL 53 95 0.37 40 P3 TWD 17 DBH

+1.75 TEC TEH 30 HOT 600UL 53 145 0.59 110 P2 TWD 25 VH3

+0.77 TEC TEH 19 HOT 600UL 54 8

0.27 71 P2 TWD 11 01C

+0.11 TEC TER 45 HOT 600UL 54__48__0.34___21__P3__T__D_16_____H_-1.75___________TEH________TEC________25______COLD________________________

54 48 0.34 21 P3 TWD 16 DBH

-1.75 TER TEC 25 COLD 600UL 54 70 0.16 113 2 SAI TSH

+0.86 TSH TSH 0.13 139 HOT 580PP 54 148 0.38 48 P2 TWD 19 VH3

-0.79 TEC TEH 19 HOT 600UL 54 158 0.15 109 2 SAI 02H

-12.40 02H 02H 0.16 184 HOT 580PP 55 23 0.55 87 P2 TWD 23 VH3

+0.80 TEC TEH 39 HOT 600UL 55 41 0.27 24 P1 SCI TSH

-0.12 TSH TSH 0.18 78 HOT 580PP 55__79__0.32___41__P3__TWD____4_DEC__-1.75___________TEC_________TE_________27_______HOT_____________________L_

55 79 0.32 41 P3 TWD 14 DBC

-1.75 TEC TEH 27 HOT 600UL 55_____85____0.42______88____P3____TWD______17____D_______+1.95_______TEC______TEH_____27____HOT_______________

55 85 0.42 88 P3 TWD 17 DBH

+1.95 TEC TER 27 HOT 600UL 55 91 0.32 50 P3 TWD 14 DBC

+1.93 TEC TEH 30 HOT 600UL 55 165 0.45 77 P2 TWD 20 VH3

+1.06 TEC TEH 27 HOT 600UL 56_____8___0.45______51____P2____TWD______20____________+0.86_______TEC______T_________44____HOT_______________

56 8 0.45 51 P2 TWD 20 VH3

+0.86 TEC TEH 44 HOT 600UL 56 28 0.59 115 P2 TWD 20 VH3

-0.92 TEC TER 29 HOT 600UL 56_____34____0.30______14_____P2____TWD_____13___.VC3______+0.70_______T___C___TEH______23____HOT_______________

56 34 0.30 14 P2 TWD 13 VC3

+0.70 TEC TEH 23 HOT 600UL 0.37 21 P2 TWD 16 VH3

+0.81 TEC TEH 23 HOT 600UL 0.48 102 P2 TWD 19 VH3

-0.83 TEC TEH 23 HOT 600UL 56 74 0.30 100 P1 SCI TSH

+0.09 TSH TSH 0.93 139 HOT 58OPP 56 84 0.63 112 P3 TWD 23 DBH

+1.70 STH TEC 4

COLD 600UL 0.85 111 P3 TWD 28 DBC

-1.53 STH TEC 4

COLD 600UL

Framatome ANP Inc.

01/24/06 17:39:07 Customer Name: San Onofre -

Unit 2 Component: S/G 89 Page 6 of 17 MAI,MCI,MMI,MVI,SAI,SCI,SVI,0-100%TWD QUERY: rpc_icodes and_0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 0.37 153 P3 TWD 15 DBC

+1.24 STH TEC 4

COLD 600UL 56 92 0.36 123 P3 TWD 22 DBC

+1.76 TEC TEH 31 HOT 600UL 0.14 154 P3 TWD 10 DBC

-1.86 TEC TEH 31 HOT 600UL 56 146 0.61 127 P2 TWD 25 VH3

-0.76 TEC TEH 19 HOT 600UL 56 150 0.40 62 P2 TWD 19 VH3

-0.85 TEC TEH 25 HOT 600UL 56 158 0.44 37 P2 TWD 20 VH3

-0.76 TEC TEH 25 HOT 600UL 57 69 0.39 27 P3 TWD 13 DBH

+1.98 STH TEC 55 COLD 600UL 57 79__0.62__101__P3__T____23____C_-1.76___TEC____EH__27__HOT____

57 79 0.62 101 P3 TWD 23 DBC

-1.76 TEC TEH 27 HOT 600UL 0.44 45 P3 TWD 18 DBC

+1.74 TEC TEH 27 HOT 600UL 57 81 0.59 125 P3 TWD 22 DBC

-1.62 STH TEC 4

COLD 600UL 57 121 0.92 19 2 SAI TSH

-3.18 TSH TSH 0.15 66 HOT 580PP 58 82 0.62 128 P3 TWD 24 DBH

+1.50 TEC TEH 28 HOT 600UL 58 ____92

____0.33

______67______3___TWD_____15___DBH_____+1.34_______TEC_____TE______30____HOT__

6---------------

58 92 0.33 67 P3 TWD 15 DBH

+1.34 TEC TEH 30 HOT 600UL 58 94 0.33 41 P3 TWD 21 DBC

-1.62 TEC TEH 31 HOT 600UL 58 96 0.21 39 P3 TWD 11 DBH

-1.83 TEC TEH 31 HOT 600UL 58 146 0.58 81 P2 TWD 23 VH3

-0.97 TEC TEH 20 HOT 600UL 59 31 0.29 52 P2 TWD 12 VH3

-0.97 TEC TEH 29 HOT 600UL 59 77 0.26 103 P1 SCI TSH

+0.11 TSH TSH 0.53 74 HOT 580PP 59 89 0.53 106 P3 TWD 20 DBH

-1.60 STH TEC 4

COLD 600UL 59 95 0.17 116 P3 TWD 9 DBC

+0.75 TEC TEH 30 HOT 600UL 0.28 126 P3 TWD 14 DBH

-2.04 TEC TEH 30 HOT 600UL 59 103 0.25 116 2 SAI 01H

+5.02 01H 01H 0.58 184 HOT 580PP 59___________147__________

0.34___101_____2__TWD___17_________-0.85TEC____TEH 19___HOT__

59 147 0.34 101 P2 TWD 17 VH3

-0.85 TEC TEH 19 HOT 600UL 0.56 100 P2 TWD 24 VH3

+0.79 TEC TEH 19 HOT 600UL

___________0.22_131___2_TWO_______3_-0.95___________T___________TE__________26_______HOT_______________________

59 157 0.25 148 P2 TWD 12 VH3

+0.81 TEC TEH 26 HOT 600UL 0.22 131 P2 TWD 11 VH3

-0.95 TEC TEH 26 HOT 600UL 59 159 0.25 120 P2 TWD 13 VH3

+0.70 TEC TEH 25 HOT 600UL 0.36 56 P2 TWD 17 VH3

-1.01 TEC TEH 25 HOT 600UL 60 28 0.38 130 P2 TWD 14 VH3

-0.97 TEC TEH 29 HOT 600UL

__________________0.47_____155_____P3____TW_____21____________+1.75______TEC_____TEH_____30___HOT______________

60 30 0.49 104 P2 TWD 18 VH3

-0.89 TEC TEH 29 HOT 600UL 60 82 0.40 13 2

SAI TSH

-0.56 TSH TSH 0.15 76 HOT 580PP 60 88 0.46 142 P3 TWD 19 DBH

+1.73 TEC TEH 30 HOT 600UL 60 94 0.39 144 P3 TWD 17 DBC

-1.74 TEC TEH 30 HOT 600UL 0.47 155 P3 TWD 21 DBH

+1.75 TEC TEH 30 HOT 600UL 63__19__0.42___125___2_TWD___18_VH3__-0.95___________TEC_________TE_________40_______HOT_______________________

60 146 0.49 101 P2 TWD 22 VH3

-0.83 TEC TEH 19 HOT

.600UL 61 35 0.22 58 P2 TWD 10 VC3

+.8TEC TEH 23 HOT 600UL 61 89 0.36 44 P3 TWD 16 DBC

-1.68 TEC TEH 30 HOT 600UL 61 99 0.34 118 P1 SCI TSH

+0.07 TSH TSH 0.81 75 HOT 580PP 61 103 0.42 15 P3 TWD 19 DBH

+1.57 TEH TEC 29 COLD 600UL 62 84 0.53 111 P3 TWD 21 DBC

-1.81 TEC TEH 27 HOT 600UL 0.72 100 P3 TWD 26 DBH

-2.16 TEC TEH 27 HOT 600UL 63 19 0.42 125 P2 TWD 18 VH3

-0.95 TEC TEH 40 HOT 600UL

Framatome ANP Inc.

01/24/06 17:39:07 Customer Name: San Onofre -

Unit 2 Component: S/G 89 Page 7 of 17 MAI,MCI,MMI,MVI,SAI,SCI,SVI,0-100%TWD QUERY: rpc icodes and_0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 63 87 0.69 107 P3 TWD 24 DBH

-1.65 STH TEC 4

COLD 60_UL 0.40 108 P3 TWD 17 DBC

-1.19 STH TEC 4

COLD 600UL 63 99 0.19 56 P3 TWD 10 DBC

-1.83 TEC TEH 34 HOT 600UL 63 145 0.37 108 P2 TWD 18 VH3

+0.87 TEC TEH 19 HOT 600UL 64 10 0.46 116 P2 TWD 19 03C

-0.97 TEC TEH 40 HOT 600UL 0.09 36 P3 TWD 4 DBH

+1.36 TEC TEH 40 HOT 600UL 64 12 0.50 97 P2 TWD 19 VH3

+0.73 TEC TEH 41 HOT 600UL 64 62 0.22 21 P1 SCI TSH

-0.12 TSH TSH 0.16 139 HOT 58OPP 64_____82____0.58______99____P3____TWO______22____DBC_____+1.50_______TEC______TEH_____27____HOT_______________

64 82 0.58 99 P3 TWD 22 DBC

+1.50 TEC TEH 27 HOT 600UL 64 84 0.44 89 P3 TWD 19 DBH

+1.50 TEC TEH 28 HOT 600UL 64__86__0.35___89__P3__TW___15_____H_-1.81___________ST__________TEC________4_____COLD_________________________

64 86 0.35 89 P3 TWD 15 DBH

-1.81 STH TEC 4

COLD 600UL 64 92 0.24 59 P3 TWD 11 DBC

-1.25 STH TEC 4

COLD 600UL 0.19 134 P3 TWD 8 DBH

-1.75 STH TEC 4

COLD 600UL 64 94 0.24 37 P3 TWD 13 DBC

-1.89 TEC TEH 31 HOT 600UL 64 124 0.60 13 2

SAI TSH

-11.64 TSH TSH 0.17 55 HOT 580PP 6150316PTO5V 0.87-----------TEC---------T----------25-------HOT------____________U____

64 150 0.31 136 P2 TWD 15 VH3

-0.87 TEC TEH 25 HOT 600UL 65 155 0.39 78 P2 TWD 18 VH3

-0.72 TEC TEH 25 HOT 600UL 65___157__0.17____107__2__S__________-0.16___________________________0.14________184______HOT__________________

65 157 0.17 107 2 SAI 02H

-0.16 02H 02H 0.14 184 HOT 580PP 0.28 101 2 SAI 02H

+0.22 02H 02H 0.16 184 HOT 580PP 66 80 0.28 49 P3 TWD 12 DBC

+1.68 TEC TEH 27 HOT 600UL 66 84 0.32 23 P3 TWD 14 DBH

-2.08 TEC TEH 27 HOT 600UL 66 88 0.88 18 P3 TWD 30 DBC

+2.01 TEC TEH 30 HOT 600UL 66__90__0__30__49___3__T__O_16____BC_-1.74___________TEC_________TEH________31_______HOT_______________________

66 90 0.30 49 P3 TWD 16 DBC

-1.74 TEC TEH 31 HOT 600UL 66 94 0.19 145 P3 TWD 10 DBC

-1.40 TEC TEH 30 HOT 600UL 0.38 83 P3 TWD 18 DBC

+2.03 TEC TEH 30 HOT 600UL 66 138 0.32 133 P2 TWD 15 08C

-0.86 TEC TEH 16 HOT 600UL 66 156 0.44 119 P2 TWD 19 VH3

-1.03 TEC TEH 26 HOT 600UL 67 83 0.54 92 P3 TWD 21 DBC

-1.70 TEC TEH 27 HOT 600UL 0.27 73 P3 TWD 12 DBH

-1.76 TEC TEH 27 HOT 600UL 67 87 0.32 166 P3 TWD 16 DBH

+1.60 TEC TEH 31 HOT 600UL 68 40 0.41 110 P2 TWD 17 VC3

+0.91 TEC TEH 23 HOT 600UL 0.20 52 P3 TWD 8 DBH

-2.01 TEC TEH 23 HOT 600UL 68 84 0.23 62 P2 TWD 10 VSM

-0.81 STH TEC 4

COLD 600UL 0.23 78 P3 TWD 10 DBH

+2.05 STH TEC 4

COLD 600UL 0.19 90 P3 TWD 9 DBC

-1.57 STH TEC 4

COLD 600UL 68 90 0.25 29 P3 TWD 12 DBH

-1.53 TEC TEH 30 HOT 600UL 0.51 86 P3 TWD 21 DBC

-1.73 TEC TEH 30 HOT 600UL 68 108 0.82 19 2

SAI TSH

-14.24 TSH TSH 0.12 59 HOT 580PP 69 67 0.18 107 2 SAI TSH

+0.07 TSH TSH 0.15 139 HOT 580PP 69 163 0.31 126 P2 TWD 15 02C

+0.91 TEC TEH 27 HOT 600UL 70 24 0.25 21 P3 TWD 9 DBC

-1.43 TEC TEH 38 HOT 600UL 0.44 6

P3 TWD 16 DBC

+2.05 TEC TEH 38 HOT 600UL 70 38 0.31 122 P2 TWD 14 VC3

+0.81 TEH TEC 45 COLD 600UL 70 52_0.51_29_P3_TWO_20_DEC_+1.67_TE__TEC_28_COLD____UL 70 52 0.51 29 P3 TWD 20 DBC

+1.67 TEH TEC 28 COLD 600UL

Framatome ANP Inc.

01/24/06 17:39:07 Customer Name: San Onofre -

Unit 2 Component: S/G 89 Page 8 of 17 MAI,MCI,MMI,MVI,SAI,SCI,SVI,0-100%TWD QUERY: rpcicodes and_0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 70 90 0.32 147 P3 TWD 17 DBH

-1.80 TEC TEH 31 HOT 600UL 70 94 0.37 115 P3 TWD 17 DBC

-1.85 TEC TEH 30 HOT 600UL 70 112 0.42 141 P2 TWD 17 03C

-0.09 TEH TEC 33 COLD 600UL 70 144 0.47 109 P2 TWD 20 VC3

-0.81 TEC TEH 20 HOT 600UL 0.32 32 P2 TWD 15 VSM

-0.85 TEC TEH 20 HOT 600UL 70____156_____0.43______121_____P2____TWD_____19______H_____+0.93_______TEC_____TEH_____26____HOT______________

70 156 0.43 121 P2 TWD 19 VH3

+0.93 TEC TEH 26 HOT 600UL 0.39 130 P2 TWD 17 VH3

-0.95 TEC TEH 26 HOT 600UL 70 158 0.43 102 P2 TWD 19 VH3

+0.72 TEC TEH 26 HOT 600UL 0.34 146 P2 TWD 16 VH3

-1.01 TEC TEH 26 HOT 600UL 71 79 0.48 91 P3 TWD 20 DBC

-1.75 TEC TEH 28 HOT 600UL 71 91 0.33 139 P3 TWD 17 DBC

-2.20 TEC TEH 31 HOT 600UL 71 93 0.21 96 P3 TWD 11 DBC

-2.02 TEC TEH 31 HOT 600UL 71--143--0.46--138--P2--TW---20--VH3--0.85-----------T-----C-----TE__-------20_------HOT----------------0-U----

71 143 0.46 138 P2 TWD 20 VH3

-0.85 TEC TEH 20 HOT 600UL 0.26 135 P2 TWD 13 04C

-0.12 TEC TEH 20 HOT 600UL 0.28 141 P2 TWD 13 VC3

-0.89 TEC TEH 20 HOT 600UL 0.43 93 P2 TWD 19 VSM

+0.50 TEC TEH 20 HOT 600UL 71 147 0.64 105 P2 TWD 26 VH3

-0.94 TEC TEH 19 HOT 600UL 0.35 107 P2 TWD 17 VC3

-0.89 TEC TEH 19 HOT 600UL 71 155 0.63 130 P2 TWD 24 VH3

+0.91 TEC TEH 26 HOT 600UL 0.51 110 P2 TWD 21 VH3

-1.16 TEC TEH 26 HOT 600UL 71 157 0.46 93 P2 TWD 20 VH3

+0.87 TEC TEH 26 HOT 60OUL 72 26 0.51 112 P2 TWD 18 VC3

+0.88 TEC TEH 29 HOT 600UL 72 28 0.19 159 P3 TWD 8 DBC

+0.66 TEC TEH 29 HOT 600UL 72 36 0.28 30 P3 TWD 11 DBC

+1.99 TEC TEH 23 HOT 600UL 72 38 0.44 138 P3 TWD 20 DBC

+1.84 TEH TEC 44 COLD 600UL 72 78 0.20 150 P2 TWD 10 VC3

+0.89 TEC TEH 27 HOT 600UL 0.18 148 P2 TWD 9 VH3

+0.86 TEC TEH 27 HOT 600UL 0.45 72 P2 TWD 20 VH3

-0.86 TEC TEH 27 HOT 600UL 72 80 0.28 140 P2 TWD 13 VC3

+0.86 TEC TEH 27 HOT 600UL 72 84 0.35 133 P3 TWD 15 DBC

-1.83 TEC TEH 27 HOT 600UL 0.28 127 P2 TWD 13 VH3

-0.84 TEC TEH 27 HOT 600UL 72 90 0.31 62 P3 TWD 14 DBC

-1.47 TEC TEH 30 HOT 600UL 72 114 0.26 126 P2 TWD 14 VC3

+0.87 TEH TEC 31 COLD 600UL 72 126 0.36 134 P2 TWD 19 VH3

-0.15 TEH TEC 34 COLD 600UL 0.40 140 P2 TWD 20 VSM

-0.80 TEH TEC 34 COLD 600UL 72______________________154_____________________

0.35___88__P2__TWO__17___H3__+0.04____TEC__T__H_25__HOT________

72 154 0.35 88 P2 TWD 17 VH3

+0.04 TEC TEH 25 HOT 600UL 72 156 0.24 137 P2 TWD 12 VC3

+0.02 TEC TEH 25 HOT 600UL 73 13 0.38 44 P2 TWD 17 VH3

+0.82 TEC TEH 40 HOT 600UL 73 51 0.27 134 P3 TWD 11 DBH

-1.44 TEH TEC 28 COLD 600UL 73 91 0.55 17 P3 TWD 23 DBC

+1.93 TEC TEH 30 HOT 600UL 74 18 0.19 130 P3 TWD 8 DBC

+1.50 TEC TEH 40 HOT 600UL 74 44 0.33 121 P2 TWD 13 VSM

+0.61 TEC TEH 22 HOT 600UL 0.69 128 P2 TWD 23 VH3

-0.85 TEC TEH 22 HOT 600UL 74__54__0.10___151__P___TWO___6______-1.25___________TE_________TEC________27______COLD________________________

74 54 0.10 151 P3 TWD 6 DBH

-1.25 TEH TEC 27 COLD 600UL

Framatome ANP Inc.

01/24/06 17:39:07 Customer Name: San Onofre -

Unit 2 Component: S/G 89 Page 9 of 17 MAI,MCI,MI,MVI,SAI,SCI,SVI,0-100%TWD QUERY: rpc_icodes and_0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 74 56 0.30 76 P3 TWD 13 DBH

+0.69 TEH TEC 28 COLD 600UL 74 90 0.41 96 P3 TWD 20 DBC

-1.83 TEC TEH 31 HOT 600UL 74 94 0.20 79 P3 TWD 14 DBH

-1.88 TEC TEH 31 HOT 600UL 0.38 103 P3 TWD 19 DBH

+2.00 TEC TEH 31 HOT 600UL 74 132 0.27 105 P2 TWD 13 VC3

-0.90 TEC TEH 16 HOT 600UL 74 140 0.41 140 P3 TWD 16 DBH

+2.22 TEC TEH 20 HOT 600UL 74 148 0.40 160 P2 TWD 19 VH3

-0.92 TEC TEH 19 HOT 600UL 0.35 98 P2 TWD 17 VSM

-0.78 TEC TEH 19 HOT 600UL 74 156 0.53 47 P2 TWD 22 VC3

-0.95 TEC TEH 26 HOT 600UL 0.38 63 P2 TWD 17 VSM

-0.95 TEC TEH 26 HOT 600UL 0.63 106 P2 TWD 25 VH3

-1.05 TEC TEH 26 HOT 600UL 75 23 0.24 24 P3 TWD 11 DBC

+1.69 TEC TEH 39 HOT 600UL 75 51 0.17 69 P3 TWD 10 DBH

-1.82 TEH TEC 27 COLD 600UL 75 71 0.37 106 P1 SCI TSH

+0.10 TSH TSH 0.47 136 HOT 580PP 75 83 0.43 65 P3 TWD 18 DBC

-1.76 TEC TEH 27 HOT 600UL 75 87 0.53 105 P3 TWD 24 DBC

-2.21 TEC TER 31 HOT 600UL 75 97 0.25 91 P2 TWD 13 VC3

-0.92 TEC TEH 30 HOT 600UL 0.22 69 P2 TWD 12 VC3

+0.85 TEC TEH 30 HOT 600UL 75 103 0.17 153 P2 TWD 9 VC3

+0.87 TEH TEC 29 COLD 600UL 75 105 0.45 126 P2 TWD 18 VSM

-0.13 STH TEC 48 COLD 600UL 0.54 124 P2 TWD 20 VH3

-0.67 STH TEC 48 COLD 600UL 76 42 0.30 124 P3 TWD 12 DBC

-1.34 TEC TEH 21 HOT 600UL 76 56 0.56 17 P3 TWD 24 DBH

+1.20 TER TEC 27 COLD 600UL 76 72 0.37 100 P1 SCI TSH

+0.07 TSH TSH 0.54 136 HOT 580PP 76___________________________78_________________

0.52__115___P2__TD__21__VC3__+0.87

__TEC__TEH 27__HOT_______

76 78 0.52 115 P2 TWD 21 VC3

+0.87 TEC TER 27 HOT 600UL 0.28 153 P2 TWD 14 VC3

-0.83 TEC TEH 27 HOT 600UL 0.23 97 P2 TWD 11 VH3

+0.79 TEC TER 27 HOT 600UL 76 90 0.36 93 P3 TWD 16 DBC

-1.47 TEC TER 30 HOT 600UL 76 114 0.35 52 P2 TWD 18 VH3

-0.75 TEH TEC 31 COLD 600UL 76 138 0.19 12 P3 TWD 9 DBC

+1.91 TEC TER 15 HOT 600UL 76 142 0.22 111 P2 TWD 12 08C

-0.52 TEC TEH 19 HOT 600UL 77 27 0.28 65 P3 TWD 10 DBC

-1.69 TEC TEH 29 HOT 600UL 77 43 0.26 129 P2 TWD 11 VH3

+0.69 TEC TEH 22 HOT 600UL 77 113 0.25 100 P2 TWD 11 VH3

-0.98 TER TEC 33 COLD 600UL 77____________137__________

0.67____93___P2___ND___26__________-0.89TC____E 15__HOT____

77 137 0.67 93 P2 TWD 26 VSM

-0.89 TEC TER 15 HOT 600UL 77 139 0.67 124 P2 TWD 26 VC3

+0.86 TEC TEH 20 HOT 600UL 0.34 40 P2 TWD 16 VSM

-0.86 TEC TEH 20 HOT 600UL 0.44 122 P2 TWD 19 VH3

-0.95 TEC TEH 20 HOT 600UL 0.25 32 P2 TWD 13 VC3

-0.82 TEC TEN 20 HOT 600UL 78 26 0.35 119 P2 TWD 14 07C

-0.15 TEC TEH 29 HOT 600UL 78 28 0.14 64 P3 TWD 6 DBC

-1.54 TEC TEH 29 HOT 600UL 78 44 0.47 125 P2 TWD 18 VSM

-0.81 TEC TER 22 HOT 600UL 78 58 0.35 22 P3 TWD 15 DBH

+2.00 TEH TEC 28 COLD 600UL 78 130 0.35 118 P2 TWD 16 VSM

-0.82 TEC TEH 16 HOT 600UL

Framatome ANP Inc.

01/24/06 17:39:07 Customer Name: San Onofre -

Unit 2 Component: S/G 89 Page 10 of 17 MAI,MCI,MMI,MVI,SAI,SCI,SVI,0-100%TWD QUERY: rpcicodes and_0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 78 136 0.32 128 P2 TWD 14 VC3

-1.07 STH TEC 48 COLD 600UL 78 150 0.46 44 P2 TWD 20 VH3

-0.75 TEC TEH 20 HOT 600UL 78 160 0.32 124 P3 TWD 15 DBC

-1.88 TEC TEH 26 HOT 600UL 79 43 0.31 44 P2 TWD 14 VH3

-0.78 TEC TEH 21 HOT 600UL 79 77 0.16 122 2 SAI TSH

+2.78 TSH TSH 0.20 74 HOT 58OPP 79__7___0.28___149__P2_T_____14_V__3_-0.81_________________C_____TEH________27_______HOT_______________________

79 79 0.28 149 P2 TWD 14 VH3

-0.81 TEC TEH 27 HOT 600UL 79 147 0.26 127 P2 TWD 14 VH3

+0.80 TEC TEH 19 HOT 600UL 80 24 0.26 118 2 SAI 05H

-0.09 05H 05H 0.42 159 HOT 58OPP 80___________________________________

106___0.25___53__P2__TWD___13_______+0.90_____E___TEC___29__COLD_______UL 80 106 0.25 53 P2 TWD 13 VH3

+0.90 TEH TEC 29 COLD 600UL k1j) 80 152 0.61 82 P2 TWD 25 VC3

+0.85 TEC TEH 25 HOT 600UL 0.36 130 P2 TWD 17 VSM

+0.98 TEC TEH 25 HOT 600UL 0.55 125 P2 TWD 23 VSM

-0.91 TEC TEH 25 HOT 600UL 0.79 87 P2 TWD 29 VC3

-0.74 TEC TEH 25 HOT 600UL 80 160 0.58 130 P3 TWD 24 DBC

-1.57 TEC TEH 25 HOT 600UL 81 43 1.03 84 P2 TWD 32 VSM

-0.97 TEC TEH 17 HOT 600UL 0.81 124 P2 TWD 28 VC3

+0.17 TEC TEH 17 HOT 600UL 81 55 0.26 42 P2 TWD 14 VH3

-0.76 TEH TEC 7

COLD 600UL 81_____75____0.27______91___________TWD_____13___.V___3____+0.83_________E_____TEC______5___COLD______________L_

81 75 0.27 91 P2 TWO 13 VC3

+0.83 TEH TEC 5

COLD 600UL 81 79 0.68 93 P2 TWD 25 VH3

-0.84 TEH TEC 19 COLD 600UL 81 105 0.38 146 P2 TWD 17 VH3

+0.91 TEH TEC 37 COLD 600UL 0.25 106 P2 TWD 12 VSM

+0.94 TEH TEC 37 COLD 60OUL 81__135__0.22__152__P2__TWD__12___H__-0.80__________________________________________________________

TECTE_5HO_

81 135 0.22 152 P2 TWD 12 VH3

-0.80 TEC TEH 5

HOT 600UL 0.39 125 P2 TWD 18 VH3

+0.80 TEC TEH 5

HOT 600UL 81 145 0.65 20 2 SAI TSH

-5.34 TSH TSH 0.17 133 HOT 580PP 81 159 0.23 80 P2 TWD 11 02H

-0.33 TEC TEH 15 HOT 600UL 0.33 102 P2 TWD 16 VH3

-0.83 TEC TEH 15 HOT 60OUL 82__28 __0.31 ___103

__P2 __T __

___14_____

-0.28---------------C---TEE-------12


HOT 82 28 0.31 103 P2 TWD 14 VH3

-0.28 TEC TEH 12 HOT 600UL 0.38 120 P2 TWD 17 VH3

-0.79 TEC TEH 12 HOT 600UL 82 44 0.45 103 P2 TWD 19 VH3

+0.83 TEC TEH 21 HOT 600UL 82 68 0.64 100 P2 TWD 26 VH3

-0.84 TEH TEC 12 COLD 600UL 0.29 146 P2 TWD 14 VH3

+0.80 TEH TEC 12 COLD 600UL 82 148 0.60 120 P2 TWD 25 VH3

-0.85 TEC TEH 10 HOT 600UL 84 40 0.61 129 P2 TWD 22 VH2

-1.14 TEC TEH 18 HOT 600UL 84 54 0.18 92 2

SAI VC3

+0.17 VC3 VC3 0.33 116 COLD 560P2 84 88 0.35 110 P2 TWD 15 VH2

+0.87 TEH TEC 15 COLD 600UL 86 130 0.33 115 P2 TWD 15 VH2

-0.83 TEC TEH 5

HOT 600UL 87 25 0.39 24 2

SAI 04H

+0.01 04H 04H 0.25 159 HOT 58OPP 1.67 18 2

SAI 04H

+0.30 04H 04H 0.22 159 HOT 580PP 1.47 16 2

SAI 04H

+0.68 04H 04H 0.17 159 HOT 58OPP 87 49 0.40 102 P2 TWD 16 VH2

+0.91 TEH TEC 6

COLD 600UL 87 121 0.39 128 P2 TWD 19 VH2

-0.69 TEH TEC 42 COLD 600UL 88___32__0.41____117___2__S__________-0.33___________________________0.39________162______HOT__________________

88 32 0.41 117 2 SAI 06H

-0.33 06H 06H 0.39 162 HOT 580PP 0.21 79 2 SAI 06H

+0.63 06H 06H 0.60 162 HOT 580PP 88__40__0.__3__134__P2_TWD___20______-0.80___________TEC_________TEE________18_______HOT_______________________

88 40 0.53 134 P2 TWD 20 VH2

-0.80 TEC TEH 18 HOT 600UL

4uw

Framatome ANP Inc.

01/24/06 17:39:07 Customer Name: San Onofre -

Unit 2 Component: S/G 89 Page 11 of 17 MAI,MCI,MMI,MVI,SAI,SCI,SVI,0-100%TWD QUERY: rpcicodes and_0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE em=m mes==c me=====~me -==

e====

=- mme

==

:===

====me~mmgeem

=

==

e==

=

==

-1:11mm~emeee 0.27 107 P2 TWD 12 VSM

-0.80 TEC TEH 18 HOT 600UL 88 44 0.68 134 P2 TWD 25 VH2

-0.82 TEC TEH 21 HOT 600UL 88__50__0.39___145__P2_T_____15_V____-0.84___________TEH_________TEC________6_____COLD____________________UL___

88 50 0.39 145 P2 TWD 15 VH2

-0.84 TEH TEC 6

COLD 600UL 88 60 0.41 128 P2 TWD 16 VH2

-0.78 TEH TEC 10 COLD 600UL 88 88 0.20 118 P2 TWD 10 VH2

+0.90 TEH TEC 15 COLD 600UL 88 140 0.46 109 P2 TWD 19 VH2

+1.07 TEC TEH 11 HOT 600UL 88 152 0.38 135 P2 TWD 17 VH2

-0.83 TEC TEH 15 HOT 600UL 90_____20____0.32______142_____P2____TWD______14______H2____+1.02_______TEC______TEH_____8___HOT___-___________

90 20 0.32 142 P2 TWD 14 VH2

+1.02 TEC TEH 8

HOT 600UL 90 38 0.54 110 P2 TWD 22 VH2

-1.10 TEC TEH 12 HOT 600UL 90__52__0__62__120__P2_T_____22____2_-0.84___________TE__________TEC________6_____COLD____________________UL___

90 52 0.62 120 P2 TWD 22 VH2

-0.84 TEH TEC 6

COLD 600UL 90 56 0.28 136 P2 TWD 13 VC2

-0.68 TEH TEC 7

COLD 600UL 0.14 110 2 SAI VC2

-0.68 VC2 VC2 0.21 116 COLD 560P2 91 35 1.53 19 2

SAI 05H

+0.18 05H 05H 0.29 162 HOT 580PP 0.20 78 2

SAI 05H

+1.04 05H 05H 0.22 162 HOT 580PP 91 43 0.52 91 P2 TWD 21 06C

-0.92 TEC TEH 17 HOT 600UL 0.13 132 2 SAI TSH

+0.28 TSH TSH 0.20 113 HOT 580PP 92 44 0.18 63 2

SAI TSH

+0.66 TSH TSH 0.30 111 HOT 580PP 0.09 101 2 SAI TSH

+1.52 TSH TSH 0.20 111 HOT 580PP 93 33 0.50 64 P2 TWD 20 VH2

+1.08 TEC TEH 12 HOT 600UL 93 139 0.39 92 P2 TWD 18 09H

-0.92 TEC TEH 10 HOT 600UL 94 22 0.26 94 P2 TWD 12 02C

+1.05 TEC TEH 8

HOT 600UL 0.52 140 P2 TWD 20 VH2

+0.91 TEC TEH 8

HOT 600UL 94 26 0.55 121 P2 TWD 21 VH2

+1.00 TEC TEH 8

HOT 600UL 94 30 0.28 63 P3 TWD 12 DBH

+1.87 TEC TEH 12 HOT 600UL 0.29 109 2 SAI DBH

+1.35 DBH DBH 0.42 199 HOT 560P2 94 50 0.22 120 P2 TWD 12 05C

-0.11 TEH TEC 5

COLD 60OUL 94___________146__________

0.25___118_____2__T_____13______3__

-0.88TEC____TEH 10__HOT___

94 146 0.25 118 P2 TWD 13 VH3

-0.88 TEC TEH 10 HOT 600UL 94 154 0.45 36 P2 TWD 20 VH2

-1.24 TEC TEH 16 HOT 600UL 95 35 0.66 64 P2 TWD 25 VH2

+0.97 TEC TEH 12 HOT 600UL 96 40 0.20 30 P3 TWD 10 DBH

-1.98 TEC TEH 18 HOT 600UL 96__48__ 0.49__

118__

P2__ T____19__V_2_

0.89_ _

TEHTEC_6_COLD_____L 96 48 0.49 118 P2 TWD 19 VH2

-0.89 TEH TEC 6

COLD 600UL 96 52 0.40 133 P2 TWD 16 VH2

-0.80 TEH TEC 6

COLD 600UL 96 54 0.15 18 P3 TWD 8 DBH

+1.09 TEH TEC 7

COLD 600UL 96 86 1.25 15 2

SAI TSH

-11.91 TSH TSH 0.20 161 HOT 580PP 96 152 0.38 97 P2 TWD 17 VH2

+0.94 TEC TEH 15 HOT 600UL 97_____37 ____0.56 ______101_____P2____T_______22______C_____+0.82_______TEC_____TE______12

____HOT _______________

97 37 0.56 101 P2 TWD 22 VC3

+0.82 TEC TEH 12 HOT 600UL 98____146_____0.75______106_____P2____T_______28______________0.89______TEC_____TEH_____10____HOT___________U__

97 147 0.52 50 P2 TWD 23 VH2

+0.86 TEC TEH 10 HOT 600UL 98 146 0.75 106 P2 TWD 28 VH2

+0.89 TEC TEH 10 HOT 600UL 100 140 0.86 123 P2 TWD 28 VH2

+0.76 TEC TEH 11 HOT 600UL 0.71 108 P2 TWD 25 VH2

-0.82 TEC TEH 11 HOT 600UL 101 25 0.34 115 P2 TWD 15 08H

+0.60 TEC TEH 8

HOT 600UL 101 33 0.66 85 P2 TWD 25 VH2

-0.77 TEC TEH 12 HOT 600UL

Framatome ANP Inc.

01/24/06 17:39:07 Customer Name: San Onofre -

Unit 2 Component: S/G 89 Page 12 of 17 MAI,MCI,MMI,MVI,SAI,SCI,SVI,0-100%TWD QUERY: rpc icodes and_0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE e_=--_===-_=====-_==-===-----===-=================:=======-===--==-=======---==----=====----------=============

101 39 0.34 61 P2 TWD 15 VH2

+0.78 TEC TEH 12 HOT 600UL 101 143 0.21 102 P3 TWD 11 DBH

+1.61 TEC TEH 10 HOT 600UL 101 147 0.33 123 P2 TWD 16 VH2

-0.89 TEC TEH 10 HOT 600UL 102__56__0.29__130__P2__TWD__15______-0.82___________TE__________TEC________7_____COLD_______________________L_

102 56 0.29 130 P2 TWD 15 VH2

-0.82 TEH TEC 7

COLD 600UL 102 58 0.38 84 P2 TWD 19 VH3

+0.82 TEH TEC 9

COLD 600UL 0.29 120 P2 TWD 15 VC3

-0.71 TEH TEC 9

COLD 600UL 0.25 121 P2 TWD 13 VC2

-0.82 TEH TEC 9

COLD 600UL 0.23 58 P2 TWD 12 VC3

+0.88 TEH TEC 9

COLD 600UL 102_____74____0.36_____10____P1______C_____T__H___+0.00_______T______T_______0.13______143____HOT______________

102 74 0.36 10 P1 SCI TSH

+0.00 TSH TSH 0.13 143 HOT 580PP 102 130 0.24 117 P1 SCI TSH

+0.11 TSH TSH 0.27 130 HOT 580PP 103 53 0.26 130 2 SAI 04H

+0.67 04H 04H 0.21 178 HOT l 580PP 103 137 0.44 81 P2 TWD 20 VH3

-0.90 TEC TEH 6

HOT 600UL 104 44 0.41 128 P2 TWD 18 VH2

-0.71 TEC TEH 21 HOT 600UL 104 94 0.36 138 P2 TWD 16 VSM

-0.83 TEH TEC 15 COLD 600UL 105 _____141

_____0.18_____77____P3____TWO____9_____B_____+1.63______TEC_____TEH____10____HOT__

6----------------

105 141 0.18 77 P3 TWD 9 DBH

+1.63 TEC TEH 10 HOT 600UL 105_____143_____0.20______77____P2____TWO_____11____________+1._____2___TEC_____TEH_____10____HOT______________

105 143 0.20 77 P2 TWD 11 VH2

+1.12 TEC TEH 10 HOT 600UL 105 147 0.26 88 P2 TWD 13 VH2

+1.08 TEC TEH 10 HOT 600UL 106 50 0.30 111 P2 TWO 16 VH2

-0.88 TEE TEC 5

COLD 600UL 106 62 0.28 106 P2 TWD 15 VC2

-0.85 TEH TEC 9

COLD 600UL 107 33 0.33 70 P3 TWD 15 DBC

+1.61 TEC TEH 13 HOT 600UL 107 35 0.48 103 P3 TWD 18 DBC

+1.32 TEC TEH 12 HOT 600UL 107 95 0.38 74 P2 TWD 18 VSM

+0.78 TEH TEC 14 COLD 600UL 107 103 0.49 87 P2 TWD 20 VH2

-0.89 TEH.TEC 36 COLD 600UL 108 42 0.36 94 P3 TWD 14 DBH

+2.10 TEC TEH 17 HOT 600UL 0.43 125 P3 TWD 16 DBH

-2.10 TEC TEH 17 HOT 600VL 108 48 0.43 119 P2 TWD 17 VH2

-0.79 TEH TEC 6

COLD 600UL 109 47 0.32 144 P2 TWD 14 VSM

-1.18 TEH TEC 6

COLD 600UL 0.26 87 P2 TWD 12 VC3

-0.85 TEH TEC 6

COLD 600UL 110 34 0.37 121 P2 TWD 16 VH2

+0.85 TEC TEH 12 HOT 600UL 111 43 0.44 115 P2 TWD 17 VH3

-1.00 TEC TEH 22 HOT 600UL 111_____87____0.35______101_____P2___TWO_____16____________+0.86_______T__H___T___C___14____C___LD____________L 111 87 0.35 101 P2 TWD 16 VC2

+0.86 TEH TEC 14 COLD 600UL 111 89 0.37 34 P2 TWD 17 01H

+0.91 TEH TEC 14 COLD 600UL 0.31 127 P1 SCI TSH

-0.03 TSH TSH 0.76 161 HOT 580PP 111 99 0.35 44 P2 TWD 16 09C

+0.51 TEH TEC 14 COLD 600UL 112 144 0.53 50 P3 TWD 20 DBC

+1.74 TEC TEH 11 HOT 600UL 113 37 0.63 48 P2 TWD 24 VH2

-0.98 TEC TEH 12 HOT 600UL 113 43 0.47 107 P2 TWD 19 VH2

-0.86 TEC TEH 21 HOT 600UL 113 53 0.23 86 P2 TWD 11 VC2

-0.52 TEH TEC 8

COLD 600UL 113 77 0.26 127 P2 TWD 12 VC3

+0.92 TEH TEC 19 COLD 600UL 113 105 0.41 52 P2 TWD 17 VH2

+0.89 TEH TEC 39 COLD 600UL 0.38 96 P2 TWD 16 VH3

+1.00 TEH TEC 39 COLD 600UL

Framatome ANP Inc.

01/24/06 17:39:07 Customer Name: San Onofre -

Unit 2 Component: S/G 89 Page 13 of 17 MAI,MCI,MMI,MVI,SAI,SCI,SVI,0-100%TWD QUERY: rpcicodes and_0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 113 121 0.41 140 P2 TWD 17 VSM

+0.86 TEH TEC 39 COLD 600UL 114 36 0.18 18 P3 TWD 7 DBC

-1.36 TEC TEH 12 HOT 600UL 114 40 0.52 61 P3 TWD 21 DBH

+1.38 TEC TEH 18 HOT 600UL 114 48 0.39 45 P2 TWD 18 03H

+1.06 TEH TEC 5

COLD 600UL 114 62 0.24 134 P3 TWD 13 DBH

-1.47 TEH TEC 12 COLD 600UL 114 136 0.37 132 P2 TWD 17 VC3

+0.79 TEC TEH 6

HOT 600UL 115_____39____0.89______133_____P2____TWD_____29____________+0.84_______TEC_____T___H___17____HOT______________

115 39 0.89 133 P2 TWD 29 VH1

+0.84 TEC TEH 17 HOT 600UL 115 43 0.62 153 P2 TWD 22 VH1

-0.83 TEC TEH 22 HOT 600UL 0.66 142 P2 TWD 23 VH1

+0.81 TEC TEH 22 HOT 600UL 115 47 0.36 98 P2 TWD 15 VH1

+0.87 TEH TEC 6

COLD 600UL 115 53 0.39 132 P2 TWD 17 06H

+0.82 TEH TEC 7

COLD 600UL 115 107 0.27 144 P3 TWD 12 DBH

-1.56 TEH TEC 41 COLD 600UL 116 46 0.22 119 2 SAI 06H

+0.32 06H 06H 0.43 LAR 162 HOT 58OPP 116 58 0.69 110 P2 TWD 23 VH1

-1.02 TEH TEC 10 COLD 600UL 116__102__0.36___17_P2__TWO__18______-0.92___________T__________TEC________40______COLD___________________0L___

116 102 0.36 17 P2 TWD 18 VH1

-0.92 TEH TEC 40 COLD 600UL 116 112 0.50 68 P2 TWD 22 VH1

-0.92 TEH TEC 40 COLD 600UL 116 116 0.42 15 P2 TWD 19 VH1

-0.94 TEH TEC 40 COLD 600UL 116--138-0.66--145-P2-TWO--26-VH2--1.17-----

TEC--------E 6--HOT------------

L 116 122 0.77 37 P2 TWD 26 VH1

-1.01 TEH TEC 39 COLD 600UL 116 128 0.51 103 P2 TWD 20 02H

+0.93 TEH TEC 39 COLD 600UL 116 138 0.66 145 P2 TWD 26 VH2

-1.17 TEC TEH 6

HOT 600UL 117 59 0.44 31 P3 TWD 18 DBH

-1.07 TEH TEC 10 COLD 600UL 117 75 0.18 140 P3 TWD 9 DBH

-1.31 TEH TEC 6

COLD 600UL 117 129 0.41 60 P2 TWD 17 05H

-0.18 TEH TEC 38 COLD 600UL 118 50 0.54 133 P2 TWD 20 VHE

-0.87 TEH TEC 6

COLD 600UL 118 52 0.56 138 P2 TWD 20 VH1

-0.80 TEH TEC 6

COLD 600UL 118 70 0.58 97 P2 TWD 23 VH1

-0.75 TEH TEC 13 COLD 600UL 118 106 0.38 110 P2 TWD 16 VH1

-0.63 TEH TEC 41 COLD 600UL 120_____38___0.34_____36_____2___TWO____14______.E__+_____30___TEC____TEE____L___C________14___HOT____________L 118 114 0.49 137 P2 TWD 22 VH1

-0.79 TEH TEC 40 COLD 600UL 3.57 33 2

SAI TEH

+3.24 TEH TEH 0.47 174 HOT 580PP 118 128 0.27 102 P2 TWD 12 05H

+0.69 TEH TEC 39 COLD 600UL 119 79 0.55 117 P2 TWD 22 VH3

+1.01 TEH TEC 19 COLD 600UL 119 119 0.45 36 P2 TWD 18 10H

-1.06 TEH TEC LOCOR 41 COLD 600UL 120__116__0.33___71_P___TWO__17______-0.77___________TEE________TEC________40______COLD________________________

119 121 0.45 92 P2 TWD 19 10H

-1.09 TEH TEC LOCOK 38 COLD 600UL 120 38 0.34 36 P2 TWD 14 10H

+1.30 TEC TEH LOCOK 14 HOT 600UL 120 64 0.54 139 P2 TWD 20 VH1

-0.76 TEH TEC 10 COLD 600UL 120 72 0.38 132 P2 TWD 18 VH1

-0.84 TEH TEC 12 COLD 600UL 0.37 155 P2 TWD 17 10H

-1.23 TEH TEC 12 COLD 600UL 120 74 0.96 124 P2 TWD 32 10H

-1.41 TEH TEC LOCOK 12 COLD 600UL 120 98 0.39 64 P2 TWD 16 VH1

-0.87 TEH TEC 15 COLD 600UL 120 116 0.33 71 P2 TWD 17 VH1

-0.77 TEH TEC 40 COLD 600UL

Framatome ANP Inc.

01/24/06 17:39:07 Customer Name: San Onofre -

Unit 2 Component: S/G 89 Page 14 of 17 MAI,MCI,MMI,MVISAI,SCI,SVI,0-100%TWD QUERY: rpc icodes and_0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 121 39 0.31 75 P2 TWD 13 10H

-1.25 TEC TEH 18 HOT 600UL 121 45 0.61 106 P2 TWD 21 VC2

-0.58 TEC TEH 22 HOT 600UL 121 47 0.28 124 P2 TWO 15 10H

+0.40 TEH TEC 5

COLD 600UL 121 57 0.40 85 P2 TWD 15 10C

-1.18 TEH TEC 10 COLD 600UL 121 83 0.52 127 P2 TWO 21 VC3

-0.94 TEH TEC 19 COLD 600UL 121 109 0.79 80 P2 TWD 27 10H

-1.51 TEH TEC LOCOK 43 COLD 600UL 122 52 0.43 88 P2 TWD 20 VH1

-0.91 TEH TEC 5

COLD 600UL 122 88 0.29 98 P2 TWD 13 VH1

+0.81 TEH TEC 15 COLD 600UL 0.50 78 P2 TWD 20 VH1

-0.83 TEH TEC 15 COLD 600UL 123 45 0.40 23 P3 TWO 15 DBH

+2.07 TEC TEH 21 HOT 600UL 123 117 0.23 139 P3 TWD 10 DBH

-1.81 TEH TEC 41 COLD 600UL 124 50 0.60 138 P2 TWD 22 VH1

-0.99 TEH TEC 6

COLD 600UL 124__58__0.59__124__P2__TWO__21______-0.83___________TEH________TEC________10______COLD______________________L_

124 58 0.59 124 P2 TWO 21 VH1

-0.83 TEH TEC 10 COLD 600UL 124_____98____0.68______19____P_____TWO____23______________2.00______TE_____T___C___15____COLD________________L 124 64 0.41 146 P2 TWO 16 VH1

-0.76 TEH TEC 10 COLD 600UL 124 98 0.68 19 P3 TWO 23 DBH

+2.00 TEH TEC 15 COLD 600UL 124 100 0.66 140 P2 TWO 24 VH1

-0.91 TEH TEC 15 COLD 600UL 125 53 0.34 130 P2 TWO 15 VH1

-0.93 TEH TEC 8

COLD 600UL 125 55 0.22 98 P3 TWD 9 DBH

+2.07 TEH TEC 8

COLD 600UL 125 77 0.32 109 P2 TWD 14 VH1

+0.75 TEH TEC 20 COLD 600UL 0.23 60 P2 TWD 11 VH1

-0.96 TEH TEC 20 COLD 600UL 125 97 0.27 113 P2 TWO 12 VH3

+0.87 TEH TEC 15 COLD 600UL 125 111 0.23 170 P3 TWD 12 DBH

+1.81 TEH TEC 40 COLD 600UL 125 119 0.28 77 P3 TWD 12 DBH

+1.59 TEH TEC 41 COLD 600UL 126 48 0.51 126 P2 TWD 19 VH1

-1.20 TEH TEC 6

COLD 600UL 126 52 0.11 132 2 SAI 06H

+20.18 067H 0.45 191 HOT 580PP 0.12 127 2 SAI 06H

+21.42 067H C

0.4 191 HOT 580PP 0.24 102 2 SAI 06H

+22.68 06H 07H 0.91 191 HOT 580PP 0.11 83 2

SAI 06H

+28.53 06H 07H 0.62 191 HOT 580PP 0.33 126 P2 TWD 15 VH1

-1.09 TEH TEC 5

COLD 600UL 126 56 0.56 128 P2 TWO 24 VH1

-1.03 TEH TEC 42 COLD 600UL 126 102 0.23 26 P3 TWD 12 DBH

-1.66 TEH TEC 42 COLD 600UL 126 108 0.24 127 P3 TWO 11 DBH

-1.55 TEH TEC 43 COLD 600UL 126 120 0.42 72 P2 TWD 18 VH1

-1.03 TEH TEC 38 COLD 600UL 126 122 0.57 124 P2 TWO 22 VH1

-1.16 TEH TEC 39 COLD 600UL 127 111 0.25 147 P2 TWO 11 04H

-0.44 TEH TEC 41 COLD 600UL 127 123 0.30 121 P2 TWO 14 09C

-1.24 TEH TEC 38 COLD 600UL 128 56 0.19 167 P3 TWD 11 DBH

+1.99 TEH TEC 7

COLD 600UL 0.42 155 P2 TWO 20 VH1

-0.84 TEH TEC 7

COLD

.600UL 128 72 0.23 132 P2 TWO 12 10H

+0.86 TEH TEC 12 COLD 600UL 0.32 145 P2 TWD 16 10H

-0.98 TEH TEC 12 COLD 600UL 128 92 0.44 61 P2 TWD 20 06H

+0.90 TEH TEC 14 COLD 600UL 129 47 0.49 148 P2 TWD 19 10H

+0.76 TEH TEC 6

COLD 60U

Framatome ANP Inc.

01/24/06 17:39:07 Customer Name: San Onofre -

Unit 2 Component: S/G 89 Page 15 of 17 MAI,MCI,MMI,MVI,SAI,SCI,SVI,0-100%TWD QUERY: rpcicodes and_0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 0.37 44 P3 TWD 16 DBH

-1.53 TEH TEC 6

COLD 600UL 0.36 137 P3 TWD 15 DBH

+1.64 TEH TEC 6

COLD 600UL 129 49 0.34 103 P2 TWD 14 VH1

-0.87 TEH TEC 6

COLD 600UL 0.35 96 P2 TWD 14 VH1

+0.91 TEH TEC 6

COLD 600UL 129 73 0.23 99 P3 TWD 10 DBH

+2.02 TEH TEC 13 COLD 600UL 129 89 0.14 57 P2 TWD 7 VH2

-0.89 TEH TEC 15 COLD 600UL 0.22 136 P2 TWD 11 VH2

+0.93 TEH TEC 15 COLD 600UL 129 109 0.36 146 P2 TWD 16 10H

-0.99 TEH TEC 43 COLD 600UL 130 48 0.37 85 P2 TWD 15 02C

-0.17 TEH TEC 6

COLD 600UL 130 74 0.34 121 P2 TWD 15 10H

+0.83 TEE TEC 13 COLD 600UL 130 78 0.18 53 P2 TWD 9 10H

-1.20 TEH TEC 19 COLD 600UL 130 94 0.45 123 P2 TWD 18 VH1

-0.85 TEH TEC 15 COLD 600UL 0.39 106 P2 TWD 16 VH1

+0.83 TEH TEC 15 COLD 600UL 132 56 0.47 102 P2 TWD 22 VH1

-0.96 TEH TEC 21 COLD 600UL 132 74 0.25 77 P3 TWD 14 DBH

+1.72 TEH TEC 21 COLD 600UL 132 106 0.60 126 P2 TWD 25 10H

-1.12 TEH TEC 42 COLD 600UL 132 122 0.45 134 P2 TWD 21 VH1

-0.74 TEH TEC 42 COLD 600UL 133 55 0.21 89 P2 TWD 9 02H

+0.25 TEH TEC 22 COLD 600UL

%40W 133 81 133 119 133 125 134 64 134 76 134 80 134 124 135 67 135 71 136 68 136__76 136 76 136 78 0.48 0.49 0.32 0.26 0.27 0.34 0.41 0.21 0.32 0.20 0.44 0.31--

0.31

0. 31 0.20 0.21 0.23 121 88 65 85 131 94 5

99 141 70 62 10 58 101 53 89 P2 TWD 18 VH1 P2 TWD 20 VH1 P2 TWD 15 01C P2 TWD 11 VH3 P2 TWD 12 VC3 P2 TWD 17 VH1 P3 TWD 16 DBH P2 TWD 11 VC3 P3 TWD 17 DBH P3 TWD 12 DBH P2 TWD 21 VH1 P3 TWD 12 DBH P2 TWD 16 VHl P3 TWD 11 DBH P2 TWD 11 VH1 P2 TWD 13 VH1

+0.92

+0.97

+0. 90

-0.89

-0.81

-0.82

+2.04

+0.62

-1.61

-1.56

-0.77

+2.03

+0.85

+1.53

-1.02

-1.04 TEH TEC TEE TEC TEH TEC TEE TEC TEH TEC TEE TEC TEH TEC 01C TEH TEH TEC TEE TEC TEH TEC TEE TEC TEH TEC TEE TEC TEE TEC TEH TEC 22 43 43 22 22 21 22 105 21 21 21 22 21 21 42 42 COLD COLD--

COLD COLD--

COLD COLD--

COLD COLD COLD COLD COLD COLD COLD--

COLD COLD COLD COLD COLD COLD COLD 60OUL 60_ UL 600UL 600UL

60.

_L 600UL 600UL 60.OUL 600UL 60_ UL 600UL

60. UL 600UL 60._ L 600UL 600UL 136 110 136__116 136 116 137 69 0.29 64 P2 TWD 12 VHl

+0.55 TEH TEC 22 COLD 600UL 137 71 0.28 89 P3 TWD 12 DBH

-1.66 TEH TEC 22 COLD 600UL 137 117 0.42 109 P2 TWD 18 VHl

-0.21 TEH TEC 43 COLD 600UL 0.34 144 P3 TWD 14 DEH

+2.00 TEH TEC 43 COLD 600UL 138_____58____0.46______30____P3____TWO_____17____DE______+1.72_______TEE_____TEC_____22____COLD_______________

138 58 0.46 30 P3 TWD 17 DBH

+1.72 TEH TEC 22 COLD 600UL 1I~w 138 64 0.25 124 P2 TWD 11 10H

+0.84 TEH TEC 22 COLD 600UL 138 80 0.34 71 P2 TWD 17 VH1

-0.85 TEH TEC 21 COLD 600UL 138__102__0.35_109__P2_TWO__17_V___-0.63___________TEE________TEC________42_______COLD________________________

138 102 0.35 109 P2 TWD 17 VH1

-0.63 TEH TEC 42 COLD 600UL

Framatome ANP Inc.

Customer Name: San Onofre -

Unit 2 MAI,MCI,MMI,MVI,SAI,SCI,SVI,0-100%TWD QUERY: rpcicodes and_0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION

=

=

-======

=

-as

=

=

==

01/24/06 17:39:07 Component: S/G 89 Page 16 of 17 EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

=========:=======

138 116 0.53 111 P2 TWD 21 VH1

-0.79 TEH TEC 43 COLD 600UL 139 61 0.23 99 P2 TWD 10 09C

-1.15 TEH TEC 22 COLD 600UL 139 103 0.51 114 P2 TWD 22 VH2

+0.87 TEH TEC 42 COLD 600UL 139 115 0.24 131 P3 TWD 11 DBH

+1.64 TEH TEC 43 COLD 600UL 140___76_0.36___77__P2_TW____18______-0.85___________TE_________TEC________21______COLD___________________UL___

140 76 0.36 77 P2 TWD 18 VH1

-0.85 TEH TEC 21 COLD 600UL 140 90 0.32 54 P2 TWD 15 VH1

-0.85 TEH TEC 26 COLD 600UL 140 112 0.36 93 P3 TWD 15 DBC

+1.23 TEH TEC 43 COLD 600UL 141 67 0.28 75 P2 TWD 12 09C

-1.05 TEH TEC 22 COLD 600UL 142_____72____0.36______1_________3__TWD_____18____DBC_____+1.55_______TE_____TEC_____21____COLD____________UL_

141 89 0.30 141 P2 TWD 15 VH1

-0.68 TEH TEC 25 COLD 600UL 141 103 0.27 51 P2 TWD 13 VH3

-1.00 TEH TEC 43 COLD 600UL 0.25 78 P2 TWD 12 VH3

+0.98 TEH TEC 43 COLD 600UL 141 109 0.46 95 P2 TWD 21 VH3

+0.00 TEH TEC 42 COLD 600UL 142 72 0.36 111 P3 TWD 18 DBC

+1.55 TEH TEC 21 COLD 600UL 142 88 0.29 86 P2 TWD 13 VH1

-0.90 TEH TEC 26 COLD 600UL 142 92 0.48 97 P2 TWD 21 VH1

-0.85 TEH TEC 25 COLD 600UL 143 71 0.26 113 P2 TWD 11 VH2

-0.93 TEH TEC 22 COLD 600UL 0.52 127 P3 TWD 19 DBH

+2.25 TEH TEC 22 COLD 600UL 0.63 102 P2 TWD 22 VH1

-0.87 TEH TEC 22 COLD 600UL 0.56 106 P2 TWD 20 VHD

+0.76 TEH TEC 22 COLD 600UL 143 73 0.36 106 P2 TWD 14 VH1

+0.87 TEH TEC 22 COLD 600UL 1.06 124 P2 TWD 30 VC1

-0.82 TEH TEC 22 COLD 600UL 0.77 89 P2 TWD 25 VC2

-0.85 TEH TEC 22 COLD 600UL 0.41 135 P3 TWD 16 DBC

+1.89 TEH TEC 22 COLD 600UL 0.49 115 P3 TWD 18 DBC

-1.33 TEH TEC 22 COLD 600UL 144_____78____0.23______138_____P2___TWD_____13______C_____+0.85_______T______TEC_____21____COLD______________L 143 75 0.25 63 P3 TWD 14 DBC

-1.70 TEH TEC 21 COLD 600UL 143 81 0.35 81 P2 TWD 14 VC1

-0.80 TEH TEC 22 COLD 600UL 143 87 0.43 103 P3 TWD 19 DBC

+2.04 TEH TEC 25 COLD 600UL 0.32 139 P2 TWD 1S 10C

+0.82 TEH TEC 25 COLD 600UL 0.18 91 P3 TWD 9 DBC

-1.86 TEH TEC 25 COLD 600UL 145_____89____0.38______116_____P2___TWO_____18______C_____+0.85_______TEH____TEC_____25____COLD______________L 143 91 0.22 36 P3 TWD 11 DBH

+1.65 TEH TEC 25 COLD 600UL 145_____99____0.48______128_____P3___TWD_____19____DBH_____+2.16_______TEH____TEC_____26____COLD____________UL_

143 103 0.64 72 P3 TWD 25 DBH

+1.89 TEH TEC 42 COLD 600UL 146_____78____0___49____110_____P3___T___D___18____DB______+1.48_______TEH____TEC_____22____COLD____________U__

143 109 0.57 94 P3 TWD 21 DBC

-1.93 TEH TEC 43 COLD 600UL 144 78 0.23 138 P2 TWD 13 VC1

+0.85 TEH TEC 21 COLD 600UL 144 84 0.23 100 P3 TWD 13 DBC

-1.83 TEH TEC 21 COLD

.600UL 0.14 58 P3 TWD 8 DBC

+1.75 TEH TEC 21 COLD 600UL 144 90 0.25 99 P2 TWD 12 VH1

-0.87 TEH TEC 26 COLD 600UL 144 102 0.25 120 P3 TWD 13 DBH

-1.59 TEH TEC 42 COLD 600UL 145 81 0.16 51 P2 TWD 9 VH1

+0.22 TEH TEC 42 COLD 600UL 0.83 129 P2 TWD 31 VH1

+0.90 TEH TEC 21 COLD 600UL 0.61 29 P3 TWD 26 DBH

+1.60 TEH TEC 21 COLD 600UL 145 89 0.38 116 P2 TWD 18 VC2

+0.85 TEH TEC 25 COLD 600UL 0.23 156 P3 TWD 12 DBH

+2.00 TEH TEC 25 COLD 600UL 145 99 0.48 128 P3 TWD 19 DBH

+2.16 TEH TEC 26 COLD 600UL 145 103 0.69 114 P3 TWD 24 DBH

+1.59 TEH TEC 43 COLD 600UL 146 78 0.49 110 P3 TWD 18 DBH

+1.48 TEH TEC 22 COLD 600UL

Framatome ANP Inc.

Customer Name: San Onofre -

Unit 2 MAI,MCINMI,MVI,SAI,SCI,SVI,0-100%TWD QUERY: rpc icodes and_0-100%twd.qry k@

ROW LINE VOLTS DEG CHN IND %TW LOCATION 1 4

6 =========

42 P

=

146 88 0.60 42 P3 TWD 23 DBC 01/24/06 17:39:07 Component: S/G 89 Page 17 of 17

====:=

EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE TEH TEC 26 COLD 600UL

+1.75 Total Tubes

504 Total Records: 639

Inservice Inspection of Steam Generator Tubes Attachment Special Report Page 1 of 4 Appendix 5 Sleeve Inspection Summary Steam Generator E-088

Framatome ANP Inc.

Customer Name: San Onofre - Unit 2 1/31/2006 9:01:20 AM Component: S/G 88 Page 2 of 4 All OBS and PCS in sleeves QUERY: QueryMl[l]

ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

,_=

==

=

=_

==

==

==_

=

__=

._========

==

,==

==

55

===S==5 55555_

,,=

=5

==

=

==

S====

44 42 0.56 16 4

PCS SBH

+5.66 TO+7.05 SBH SBH 56 HOT 500SP OBS SBH

+7.05 SBH SBH 77 HOT 500SP 25 49 0.64 22 4

PCS SBH

+2.74 TO+3.E7 SBH SBH 56 HOT 500SP OBS SBH

+3.93 SBH SBH 77 HOT 500SP 64 52 1.27 357 4 PCS SBH

+2.84 TO+8.31 SBN SBH 59 HOT 500SP OBS SBH

+8.31 SBH SBH 76 HOT 500SP 57 55 1.30 19 4

PCS SBH

+2.86 TO+5.96 SBH SBH 59 HOT 500SP OBS SBH

+5.96 SBH SBH 76 HOT 500SP 16 56 0.99 13 4

PCS SBH

+1.55 TO+11.58 SBH STH 56 HOT 500SP 13 57 1.54 189 4 PCS SBH

+2.24 TO+9.67 SBH STH

- HOT 500SP 90 58 1.05 13 4

PCS SBH

+2.72 TO+4.66 SBH SBH 59 HOT 500SP OBS SBH

+4.66 SBH SBH 76 HOT 500SP 83 59 OBS SBH

+2.74 SBH SBH HOT 500SP 12 62 0.14 67 4

PCS SBH

+9.28 TO+15.53 SBH STH 56 HOT 500SP 83 63 1.39 14 4

  • PCS SBH

+3.07 TO+7..03 SBH SBH 59 HOT 500SP OBS SBH

+7.03 SBH SBH 71 HOT 500SP 59 65 0.36 32 4

PCS SBH

+2.88 TO+3.34 SBH SBH 60 HOT 500SP OBS SBH

+3.27 SBH SBH 71 HOT 500SP 60 66 0.99 5

4 PCS SBH

+11.64 TO+12.57 SBH SBH 60 HOT 500sP OBS SBN

+7.23 SBH SBH 71 HOT 500SP 64 66 1.16 19 4

PCS SBH

+4.10 TO+8.67 SBH SBH 60 HOT 500SP OBS SBH

+8.62 SBH SBH 71 HOT 500SF 48 68 0.34 55 4

PCS SBH

+2.83 TO+3.;1 SBH SBH 60 HOT 500SP OBS SBH

+3.52 SBH SBH 71 HOT 500SP 47 69 1.06 19 4

PCS SBN

+2.87 TO+6.89 SBH SBH 59 HOT 500SP OHS SBH

+6,89 SBH SBH 71 HOT 500Sp 30 70 1.29 12 4

PCS SBH

+3.35 TO+5.85 SBH SBH 59 HOT 500SP OBS SBH

+5.85 SBH SBH 71 HOT 500SP 53 71 0.86 18 4

PCS SBH

+2.51 TO+15.86 SBH STH 60 HOT 500SP 46 72 1.10 9

4 PCS SBH

+3.09 TO+9.16 SBH SBH 59 HOT 500SP OBS SBH

+9.16 SBH SBH 71 HOT 500SP 99 75 1.37 13 4

PCS SBH

+3.03 TO+5.17 SBH SBH 59 HOT 500SP OBS SBH

+5.17 SBH SBH 71 HOT 500SP 44 76 0.34 181 4 OBS SBH

+6.57 SBN SBH HOT 500SP 53 79 1.10 35 4

PCS SBH

+2.72 TO+6.39 SBH SBH 61 HOT 500SP OBS SBH

+6.71 SBH SBH 71 HOT 500SP 67 83 1.98 15 4

PCS SBH

+4.20 TO+8.87 SBH STH 63 HOT 500SP 70 84 1.25 42 4

PCS SBH

+2.94 TO+7.89 SBH SBH HOT 500SP OBS SBH

+7.89 SBH SBH 71 HOT 500SP 71 89 1.03 27 4

PCS SBH

+6.09 TO+15.47 SBH STH 63 HOT 500SP 68 90 0.53 98 4

PCS SBH

+2.68 TO+8.25 SBH SBH

- HOT 500SP OBS SBH

+8.25 SBH SBH 71 HOT 500SP 59 91 4

OBS SBH

+3.21 SBH SBH 76 HOT 500SP 63 91 1.01 180 4 PCS WCH

-0.68 TO-4.29 SBH STH 63.

HOT 500SP

_r ---

67 91 0.90 9

4 OBS SBH

+2.62 SBH SBH 76 HOT 500SP 56 92 0.42 3

4 OHS SBH

+3.06 SBH SBH NOSIP HOT 500SP 68 94 1.35 7

4 PCS SBH

+2.78 TO+6.08 SBH SBH 63 HOT 500SP OHS SBH

+6.08 SBH SBN 76 HOT 500SP 85 95 OBS SBH

+2.87 SBH SBH 71 HOT 500SP

Framatome ANP Inc.

Customer Name: San Onofre -

Unit 2 1/31/2006 9:01::20 AN Component:

S/G 88 Page 3 of 4 All OBS and PCS in sleeves QUERY: QueryMl[l]

ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL M LEG PROBE 63 97 1.53 31 4

PCS SBH

+2.82 TO+8.29 SBH SBH 63 HOT 500SP OBS SBH

+8.29 SBH SBH 76 HOT 500SP 81 97 1.28 7

4 PCS SBH

+2.66 TO+5.33 SBH SBH 63 HOT 500SP OBS SBH

+5.33 SBH SBH 71 HOT 500sP 91 97 OBS SBH

+3.18 SBH SBH HOT 500SP 64 98 0.90 12 4

PCS SBH

+2.88 TO+15.62 SBH STH 63 HOT S00SP 61 99 0.38 15 4

PCS SBH

+9.14 TO+14.98 SBH STH HOT 500SP 68 102 OBS SBH

+2.75 SBH SBH 76 HOT 500SP 41 103 OBS SBH

+3.53 SBH SBH 71 HOT 500SP 52 104 1.48 23 4

PCS SBH

+2.79 TO+11.51 SBH SBH 57 HOT 500SP OBS SBH

+11.55 SBH SBH 76 HOT 500SP 80 104 1.27

'31 4 PCS SBH

+2.59 TO+8.S5 SBH SBH 57 HOT 500SP OBS SBH

+6.97 SBH SBH 71 HOT 500SP 47 105 0.90 40 4

PCS SBH

+2.86 TO+7.73 SBH SBH 55 HOT 500SP 4

OBS SBH

+7.73 SBH SBH 76 HOT 500SP 36 108 1.05 37 4

PCS SBH

+3.59 TO+5.-97

-SBH SBH 55 HOT 500SP 1.51 191 4 PCS SBH

+3.59 TO+15.97 SBH STH 71 HOT 500SP 70 108 1.50 13 4

PCS SBH

+7.75 TO+15.77 SBH STH 58 HOT 500SP 67 109 0.87 167 4 PCS SBH

+9.70 TO+15.80 SBH STH HOT 500SP 83 Ill OBS SBH

+2.72 SBH SBH 71 HOT 500SP 44 114 0.93 41 4

PCS SBH

+5.18 TO+11.88 SBH STH 55 HOT 500SF 52 114 1.43 20 4

PCS SBH

+2.47 TO+9.23 SBH STH 58 HOT 500SP 82 114 1.34 10 4

PCS SBH

+2.66 TO+7.91 SBH SBH HOT 500SP OBS SBH

+7.81 SBH SBH 71 HOT 500SP 30 118 OBS SBH

+3.65 SBH SBH HOT 500SP 75 119 1.73 190 4 PCS SBH

+4.67 TO+15.96 SBH STH 58 HOT 500SP 83 119 1.76 179 4 PCS SBH

+6.50 TO+15.47 SBH STH HOT 500SP 13 121 0.92 22 4

PCS SBH

+2.73 TO+8.57 SBH SBH 71 HOT 500SP OBS SBH

+8.80 SBH SBH 248 HOT 500SP 27 121 0.89 32 4

PCS SBH

+2.83 TO+5.25 SBH SBH 55 HOT 500SP I

OBS

-SBH

+5.25 SBH SBH 71 HOT 500SP 83 121 1.52 190 4 PCS SBH

+5.28 TO+15.92 SBH STH 58 HOT 500SP 25 127 1.32 18 4

PCS SBH

+2.79 TO+8.75 SBH SBH 55 HOT 500SP OBS SBH

+8.75 SBH SBH 71 HOT 500SP 39 131 1.26 192 4 PCS SBH

+2.93 TO+8.55 SBH SBH 58 HOT 500SP OBS SBH

+8.34 SBH SBH 71 HOT 500SP 10 132 14.48 134 4 PCS SBH

+1,74 TO+12.52 STH SBH 5S HOT 500SP 58 134 1.20 14 4

PCS SBH

+0.31 TO+7.12 STH SBH 58 HOT 500SP

-- M---- _________

15 135 1.21 13 4

PCS SBH

+2.78 TO+6.34 SBH SBH HOT 500SP OBS SBH

+6.14 SBH SBH 71 HOT 500SP 7

139 1.06 183 4 PCS SBH

+1.92 TO+3.44 SBH SBH 58 HOT 500SP OBS SBH

+4.10 SBH SBH 71 HOT 500SP 37 147 OBS SBH

+2.88 SBH SBH HOT 500SP 65 149 1.24 17 4

PCS SBH

+2.59 TO+4.50 SBH SBH 58 HOT 500SP OBS SBH

+4.36 SBH SBH 61 HOT 500SP 57 151 1.23 20 4

PCS 1.27 8

4 OBS SBH

+0.91 TO+4.28 SBH SBH SBH

+5.75 SBH SBH 58 HOT 500SP 71 HOT 500SP

Framatome ANP Inc.

Cuistnmer Name: San Onofre -

Unit 2

  • _i/31/2006 9:01:20 AM Component: S/G 88 Page 4 of 4 All OBS and PCS in sleeves QUERY: QueryMl[l]

ROW LINE VOLTS DEG CHN IND %TW LOCATION Total Tubes

63 Total Records: 96 EXT EXT UTIL 1 UTIL 2 CAL 4 LEG PROBE

=n

==

nt=====

=

=

==

Inservice Inspection of Steam Generator Tubes Attachment Special Report Page 1 of 3 Appendix 6 Sleeve Inspection Summary Steam Generator E-089

Framatome ANP Inc.

1/31/2006 9:\\02:11 AM Customer Name: San Onofre -

Unit 2 Component: S/G 89 Page 2 of 3 All OBS and PCS in sleeves QUERY: QueryMl[l]

ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL 4 LEG PROBE ee~~=*===nt=

==-

-====f=-==e=s===t===

=

=-

=

=

s~==--== -s

m==c

56 38 OBS SBH

+3.09 SBH SBH 73 HOT 500sP 16 42 OBS SBH

+3.89 SBH SBH HOT 500SP 45 47 1.30 8

P1 PCS SBH

+4.57 TO+15.77 SBH STH 57 HOT 500SP 24 48 0.83 15 4

PCS SBH

+2.84 TO+5.72 SBE SBH HOT 500SP OBS SBH

+5.76 SBH SBH 73 HOT 500SP 50 52 1.40 4

4 PCS SBH

+7.86 TO+13.54 SBE STH 57 HOT 500SP 39 53 1.20 188 4 PCS SBH

+2.85 TO+6.69 SBH SBH 63 HOT 500SP OBS SBH

+6.69 SBH SBH 73 HOT 500SP 24 54 1.11 186 4 PCS SBH

+8.95 TO+16.09 SBH STH-57 HOT 500SP 7 -

30 54 1.44 13 4

PCS SBH

+5.31 TO+11.06 SBH STH 63 HOT 500SP 44 54 OBS SBH

+3.36 SBH SBH 73 HOT 500SP 38 60 1.63 24 4

PCS SBH

+7.68 TO+15.71 SBH STH 63 HOT 500SP 71 63 OBS SBH

+2.99 SEE SBH 73 HOT 500SP 31 65 OBS SBH

+3.19 SBH SBH HOT 500SP 43 65 1.94 182 4 PCS SBH

+2.66 TO+15.67 SBH STH 63 HOT 500SP 64 66 0.88 21 4

PCS SBH

+2.90 TO+4.10 SBH SBH 57 HOT 500SP OBS SBH

+4.10 SBE SBH 73 HOT 500SP 55 69 OBS SBH

+3.18 SBH SBH HOT 500SP 57 69 0.66 29 P1 PCS SBH

+2.75 TO+3.79 SBH SBH 57 HOT 500SP OBS SBH

+3.78 SBH SBH 73 HOT 500SP 48 74 1.17 167 4 PCS SBH

+2.98 TO+9.16 SBE SBH 57 HOT 500SP OBS SBHE

--+9.16

-S -

--SBH SBH 180

-HOT 500Sp 51 75 1.20 172 4 PCS SBH

+3.01 TO+8.51 SBH SBH 57 HOT 500SP OBS SBH

+8.51 SBH SBH 73 HOT 500SP 57 81 OBS SBH

+3.13 SBH SBH 70 HOT 500SP 65 81 0.60 32 4

PCS SBH

+3.01 TO+16.02 SEN STH 51 HOT 500SP 86 82 1.82 9

4 PCS SBH

+4.43 TO+10.83 STH SBH HOT 500SP 68 84 1.05 3

4 PCs SBH

+2.76 TO+e.92 SBH SBH HOT 500SP OBS SBH

+8.92 SBH SBH 70 HOT 500SP 64 88 OBS SBH

+2.53 SBH SBH HOT 500SP 61 93 OBS SBH

+2.90 SBH SBH HOT 500SP 84 96 OBS SBH

+2.56 SBH SBH HOT 500SP 59 99 OBS SBH

+2.97 SBH SBH HOT 500SP 41 103 OBS SBH

+2.92 SBH SBH HOT -

500SP 48 108 1.40 185 4 PCS SBH

+2.60 TO+10.00 SSE SBH 46 HOT 500SP OBS SBH

+9.93 SBH SBH 70 HOT 500SP 24 112 OBS SBH

+2.45 SBH SBH HOT 500SP 8

114 1.01 186 4 PCS SBH

+2.63 TO+4.03 SBH SBH 46 HOT 500SP OBS SBH

+4.03 SBH SBH 70 HOT 500SP 25 115 1.20 184 4 PCS SBH

+1.98 TO+7.83 SBH STH 46 '.

HOT 500SP 38 116 OBS SBH

+2.07 SBH SBH 70 HOT 500SP 28 118 OBS SBH

+2.55 SBH SBN HOT 500SP 36 126 1.49 185 4 PCS SBH

+2.43 TO+6.49 SBH SBH 46 HOT 500SP OBS SEH

+6.49 SBH SBH 70 HOT 500SP 9

147 1.33 9

4 PCS SBH

+2.95 TO+8.98 SBH SBH 46 HOT 500SP OBS SBH

+8.98 SBE STH 70 NOT 500SP

Framatome ANP Inc.

Customer Name: San Onofre -

Unit 2 1/31/2006 9::02:il AM Component: S/G 89 Page 3 of 3 Component: S/C 89 Page 3 of 3 All OBS and PCS in sleeves QUERY: QueryMl[l]

ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

=

==

==

n====-=====

Total Tubes : 35 Total Records: 46