MONTHYEARSVP-24-059, Correction to Registration of Use of Casks to Store Spent Fuel2024-10-0404 October 2024 Correction to Registration of Use of Casks to Store Spent Fuel SVP-24-054, Deviation from BWR Vessel and Internals Project (BWRVIP) Guidelines - Inspection of Top Guide Rim Welds2024-09-11011 September 2024 Deviation from BWR Vessel and Internals Project (BWRVIP) Guidelines - Inspection of Top Guide Rim Welds SVP-24-049, Owners Activity Report Submittal Sixth 10-Year Interval 2024 Refueling Outage Activities2024-08-0707 August 2024 Owners Activity Report Submittal Sixth 10-Year Interval 2024 Refueling Outage Activities SVP-24-048, Registration of Use of Casks to Store Spent Fuel2024-07-31031 July 2024 Registration of Use of Casks to Store Spent Fuel SVP-24-046, Turbine Trip and Automatic Scram Due to Digital EHC Power Supply Intermittent Failure2024-07-22022 July 2024 Turbine Trip and Automatic Scram Due to Digital EHC Power Supply Intermittent Failure SVP-24-043, Registration of Use of Casks to Store Spent Fuel2024-07-0505 July 2024 Registration of Use of Casks to Store Spent Fuel SVP-24-041, Regulatory Commitment Change Summary Report2024-07-0505 July 2024 Regulatory Commitment Change Summary Report SVP-24-040, Registration of Use of Casks to Store Spent Fuel2024-06-25025 June 2024 Registration of Use of Casks to Store Spent Fuel SVP-24-039, Ile Post Exam Package Letter2024-06-12012 June 2024 Ile Post Exam Package Letter SVP-24-031, Automatic Actuation of Reactor Protection System During Scram Discharge Volume Leak Rate Testing2024-05-10010 May 2024 Automatic Actuation of Reactor Protection System During Scram Discharge Volume Leak Rate Testing SVP-24-034, Annual Radiological Environmental Operating Report2024-05-10010 May 2024 Annual Radiological Environmental Operating Report SVP-24-028, Independent Spent Fuel Storage Installation Annual Radioactive Effluent Release Report2024-04-26026 April 2024 Independent Spent Fuel Storage Installation Annual Radioactive Effluent Release Report SVP-24-029, Radioactive Effluent Release Report for 20232024-04-26026 April 2024 Radioactive Effluent Release Report for 2023 SVP-24-024, Corrected Radioactive Effluent Release Report for 20222024-04-0505 April 2024 Corrected Radioactive Effluent Release Report for 2022 SVP-24-023, Ile Outline Submittal Letter2024-03-29029 March 2024 Ile Outline Submittal Letter SVP-24-018, Ile Proposed Exam Submittal Letter2024-03-13013 March 2024 Ile Proposed Exam Submittal Letter SVP-23-059, Turbine Trip and Automatic Reactor Scram Due to High Moisture Separator Level2023-11-30030 November 2023 Turbine Trip and Automatic Reactor Scram Due to High Moisture Separator Level SVP-23-038, Owner'S Activity Report Submittal Fifth 10-Year Interval 2023 Refueling Outage Activities2023-08-14014 August 2023 Owner'S Activity Report Submittal Fifth 10-Year Interval 2023 Refueling Outage Activities SVP-23-031, Regulatory Commitment Change Summary Report2023-07-14014 July 2023 Regulatory Commitment Change Summary Report SVP-23-018, Radioactive Effluent Release Report for 20222023-04-28028 April 2023 Radioactive Effluent Release Report for 2022 SVP-23-016, Independent Spent Fuel Storage Installation Annual Radioactive Effluent Release Report2023-04-20020 April 2023 Independent Spent Fuel Storage Installation Annual Radioactive Effluent Release Report SVP-23-015, Annual Dose Report for 20222023-04-18018 April 2023 Annual Dose Report for 2022 SVP-23-011, Notification of Readiness for NRC 95001 Inspection (EA-22-062)2023-03-28028 March 2023 Notification of Readiness for NRC 95001 Inspection (EA-22-062) SVP-22-072, Manual Scram Due to Feedwater Regulator Valve Failure Increasing Reactor Water Level2022-12-30030 December 2022 Manual Scram Due to Feedwater Regulator Valve Failure Increasing Reactor Water Level SVP-22-061, Registration of Use of Casks to Store Spent Fuel2022-10-0404 October 2022 Registration of Use of Casks to Store Spent Fuel SVP-22-057, Response to Apparent Violation EA-22-062 and Preliminary White Finding Regarding the Failure of One Electromatic Relief Valve2022-09-15015 September 2022 Response to Apparent Violation EA-22-062 and Preliminary White Finding Regarding the Failure of One Electromatic Relief Valve SVP-22-056, Registration of Use of Casks to Store Spent Fuel2022-09-13013 September 2022 Registration of Use of Casks to Store Spent Fuel SVP-22-050, Response to NRC Inspection Report and Preliminary White Finding2022-08-18018 August 2022 Response to NRC Inspection Report and Preliminary White Finding SVP-22-046, Registration of Use of Casks to Store Spent Fuel2022-08-17017 August 2022 Registration of Use of Casks to Store Spent Fuel SVP-22-042, Owner'S Activity Report Submittal Fifth 10-Year Interval 2020 Refueling Outage Activities2022-07-22022 July 2022 Owner'S Activity Report Submittal Fifth 10-Year Interval 2020 Refueling Outage Activities SVP-22-041, Registration of Use of Casks to Store Spent Fuel2022-07-13013 July 2022 Registration of Use of Casks to Store Spent Fuel SVP-22-036, Offsite Dose Calculation Manual (ODCM) Section 12.2.2, Radioactive Gaseous Effluent Monitoring Instrumentation Report Main Chimney High Range Noble Gas Monitor2022-06-10010 June 2022 Offsite Dose Calculation Manual (ODCM) Section 12.2.2, Radioactive Gaseous Effluent Monitoring Instrumentation Report Main Chimney High Range Noble Gas Monitor SVP-22-029, Annual Radiological Environmental Operating Report for 20212022-05-13013 May 2022 Annual Radiological Environmental Operating Report for 2021 SVP-22-026, Radioactive Effluent Release Report for 20212022-04-29029 April 2022 Radioactive Effluent Release Report for 2021 SVP-22-024, Independent Spent Fuel Storage Installation Annual Radioactive Effluent Release Report2022-04-21021 April 2022 Independent Spent Fuel Storage Installation Annual Radioactive Effluent Release Report SVP-22-021, Annual Dose Report for 20212022-04-14014 April 2022 Annual Dose Report for 2021 SVP-22-018, Core Operating Limits Report for Quad Cities Unit 2 Cycle 272022-04-0808 April 2022 Core Operating Limits Report for Quad Cities Unit 2 Cycle 27 SVP-21-041, Regulatory Commitment Change Summary Report2021-07-15015 July 2021 Regulatory Commitment Change Summary Report SVP-21-040, Owner'S Activity Report Submittal Fifth 10-Year Interval 2021 Refueling Outage Activities2021-06-29029 June 2021 Owner'S Activity Report Submittal Fifth 10-Year Interval 2021 Refueling Outage Activities SVP-21-028, Annual Radiological Environmental Operating Report2021-05-13013 May 2021 Annual Radiological Environmental Operating Report SVP-21-024, Annual Dose Report for 20202021-04-22022 April 2021 Annual Dose Report for 2020 SVP-21-001, 10 CFR 50.59 /10 CFR 72.48 Summary Report2021-01-0404 January 2021 10 CFR 50.59 /10 CFR 72.48 Summary Report SVP-20-074, Technical Specifications Section 5.6.6 Post Accident Monitoring Instrumentation Report2020-10-0808 October 2020 Technical Specifications Section 5.6.6 Post Accident Monitoring Instrumentation Report SVP-20-069, Registration of Use of Casks to Store Spent Fuel2020-10-0101 October 2020 Registration of Use of Casks to Store Spent Fuel SVP-20-064, Registration of Use of Casks to Store Spent Fuel2020-09-0808 September 2020 Registration of Use of Casks to Store Spent Fuel SVP-20-056, Registration of Use of Casks to Store Spent Fuel for Quad Cities Nuclear Power Station, Units 1 and 22020-08-13013 August 2020 Registration of Use of Casks to Store Spent Fuel for Quad Cities Nuclear Power Station, Units 1 and 2 SVP-20-053, Owner'S Activity Report Submittal: Fifth 10-Year Interval 2020 Refueling Outage Activities2020-07-14014 July 2020 Owner'S Activity Report Submittal: Fifth 10-Year Interval 2020 Refueling Outage Activities SVP-20-049, Regulatory Commitment Change Summary Report2020-07-14014 July 2020 Regulatory Commitment Change Summary Report SVP-20-046, Registration of Use of Casks to Store Spent Fuel2020-06-30030 June 2020 Registration of Use of Casks to Store Spent Fuel SVP-20-035, Annual Radiological Environmental Operating Report2020-05-14014 May 2020 Annual Radiological Environmental Operating Report 2024-09-11
[Table view] |
Text
Exelcr5 n, Exelon Generation Company, LLC www.exeloncorp.com Nuclear Ouad Cities Nuclear Power Station 22710 206" Avenue North Cordova, IL 61242-9740 December 30, 2005 SVP-05-082 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555 Quad Cities Nuclear Power Station, Units 1 and 2 Renewed Facility Operating License Nos. DPR-29 and 30 NRC Docket Nos. 50-254 and 50-265
Subject:
Main Steam Safety Valve Performance at Quad Cities Nuclear Power Station
Reference:
Letter from M. Banerjee (U. S. NRC) to C. M. Crane (Exelon Generation Company, LLC), "Issuance of Safety Evaluation Related to License Condition for Main Steam Safety Valve Setpoint Tolerances and Tolerance Uncertainty Treatment Methodology (TAC Nos. MC5018 and MC5019)," dated December 7, 2005 Quad Cities Nuclear Power Station (QCNPS) operating experience indicates that the as-found lift setpoints of the Main Steam Safety Valves (MSSVs) and Target Rock safety/relief valves (S/RVs) have deviated from the Technical Specification (TS) tolerance limit of plus or minus one percent (1%) on multiple occasions. As a result of these deviations, QCNPS is currently evaluating potential actions to address this trend.
First, Exelon Generation Company, LLC (EGC) has completed a Monte Carlo statistical analysis of the MSSV network to determine an upper tolerance limit that more accurately predicts the distribution of as-found lift pressures. The intent of the analysis was to demonstrate a statistically based alternative to traditional deterministically applied setpoint drift, which assumes that all of the valves drift to the highest possible setpoint. The Monte Carlo statistical analysis, approved by the NRC in the Referenced letter, utilized MSSV data from both Dresden Nuclear Power Station (DNPS) and QCNPS.
Although the results of the Monte Carlo analysis conclude that a change to the one percent TS tolerance limit is warranted, the limiting fuel reload analyses on both QCNPS units (i.e.,
the anticipated transient without scram peak pressure and ASME overpressure analyses) have been performed assuming upper tolerances greater than those determined by the Monte Carlo analysis. Therefore, the MSSVs are capable of performing their safety function.
QCNPS intends to submit a TS amendment request to modify the setpoint tolerance to a value consistent with the Monte Carlo statistical analysis.
{g J C)
0-I December 30, 2005 U. S. Nuclear Regulatory Commission Page 2 Second, QCNPS is evaluating a design modification that would increase the safety valve relief capacity (MSSV and S/RV) in order to regain margin that was lost as a result of implementing extended power uprate and more efficient reactor core designs. This design modification involves replacing two existing Electrometric Relief Valves (ERVs) on each unit with higher capacity S/RVs. This will increase the rate at which steam can be removed from the reactor vessel, lowering the peak pressure experienced by the vessel during design basis events.
Should you have any questions concerning this report, please contact Mr. W. J. Beck at (309) 227-2800.
Respectfully, TiXthy J. Tulon Sfe Vice President Quad Cities Nuclear Power Station cc: Regional Administrator - NRC Region Ill NRC Senior Resident Inspector - Quad Cities Nuclear Power Station