ENCLOSURE 2 TMI Unit 1 Calculation No. C-1101-900-EOOO-083 Revision 2 "EAB, LPZ, and CR Doses Due to Fuel Handling Accident In Reactor Building With Hatch Doors Opened"
CC-AA-309-1001 Exelon. Revision 2 Nuclear ATTACHMENT 1 Design Analysis Cover Sheet Design Analysis (Major Revision) I Last Page No. ' 201 Analysis No.: I C-1101-900-EOOO-083 Revision: ' 2
Title:
3 EAB, LPZ, and CR Doses Due to Fuel Handling Accident In Reactor Bldg With Hatch Doors Opened EC/ECR No.: 4 ECR 05-00432 Revision: I 0 Station(s): 7 Three Mile Island Component(s):"
Unit No.:' 1I Discipline:' Mechanical Descrip. Code/Keyword: " N/A_
Safety/QA Class:" Safety Related/Class 1 System Code: '3 191,240,241,411,826 Structure: '" N/A CONTROLLED DOCUMENT REFERENCES'I Document No.: From/To Document No.: From/To C-1101-826-E410-030, Rev. 0 From C-1101-826-E260-023, Rev. 2 From C-1101-202-E620-415, Rev. 2 From C-1101-900-EOOO-072, Rev. 2 From C-1101-826-E540-020, Rev. 2 From C-1101-2S2-5412-012, Rev. 0 From C-1101-202-E620-437, Rev. 0 From Is this Design Analysis Safeguards Information? "C Yes C No 0 If yes, see SY-AA-101-106 Does this Design Analysis contain Unverified Assumptions?" Yes El No If yes, ATI/AR#:
This Design Analysis SUTPERCEDES:' C-1 101-900-EOOO-083 Revision I in its entirety.
Description of Revision This revision addresses questions from the NRC RAI associated An Preparer: 2t Thomas J. Mscisz Print I Method of Review: 2i Detailed Review E Reviewer: Moussa Mahgerefteh Z t 7/172/of Nnin Nanae I VrDaft Review Notes: Independent review 0 Peer review E An a independent third party All
?& ev..4 . G.?;tJ review was performed per HU-AA- 12 12. Changes from Rev. ' to Rev. 2 of this calculation
'%A,'u cRo cP(.t-vere reviewed and verified to be correct. The new X/Q for CR habitability used in Rev.2 were verified to be consistent with the referenced value and were correctly used in RADTRAD computer code. Based on this evaluation, the revised calculation is verified to be acceptable.
(For External AnalysesOnly)
External Approver: 24 N/A N/A N/A Hint Namn Sign Nane Date Exelon Reviewer: a N/A N/A N/A Print Name SignName Date Is a Supplemental Review Required? 2 Yes E No 0 If yes, complete Attachment 3 Exelon Approver: Ejj i)rinI N Sign Ii iSts Print Name Sign Name Date
CC-AA-309 Revision 4 l Page 15 of 16 ATTACHMENT I General Review Questions Page 1 of I pme -at DESIGN ANALYSIS NO. 1- g 00-. Eo o_ REV: I Yes No N/A
- 1. Does the Design Analysis conform to design requirements? El El
- 2. Does the Design Analysis conform to applicable codes, standards, and regulatory requirements? El
- 3. Have applicable design and safety limits been identified? El
- 4. Is the analysis method appropriate? El El
- 5. Are the methods used and recommendations given conservative relative to the design and safety limits? El
- 6. Are assumptions/Engineering Judgments explained and appropriate? El
- 7. Have appropriately verified Computer Program and versions been 171 identified, when applicable? El El
- 8. Does the Computer Program conform with the NRC SER or similar document when applicable? 13 El
- 9. Has the input been correctly incorporated into the Design Analysis? El EO El
- 10. Has the input been reviewed by all cognizant design authorities? El El
- 11. Are the analysis outputs and conclusions reasonable compared to the El inputs and assumptions? El
- 12. Are the recommendations/results/conclusions reasonable based on previous experience? El 0
- 13. Has a verification of the Design Analysis been performed by alternate methods? El El
- 14. Has all input data been used correctly and is it traceable? EO
- 15. Has the effect on plant drawings, procedures, databases, and/or plant 1:1 simulator been addressed? El E]
- 16. Has the effect on other systems been addressed? 210 El
- 17. Have any changes in other controlled documents (e.g. UFSAR, Technical Specifications, COLR, etc.) been identified and tracked? El
- 18. When applicable, are the analysis results consistent with the proposed license amendment? E El
- 19. Have other documents that have used the calculation as input been reviewed and revised as appropriate? E El
- 20. Have all affected design analyses been documented on the Affected Documents List (ADL) for the associated Configuration Change? E El
- 21. Do the sources of inputs and analysis methodology used meet current technical requirements and regulatory commitments? (If the input sources or analysis methodology are based on an out-of-date methodology or El E code, additional reconciliation may be required if the site has since committed to a more recent code)
- 22. Have supporting technical documents and references been reviewed when necessary? E El
CALCULATION NOC-ll01-900-EOOO.083 REV. No. 2 l PAGE NO.2 PAGE NUMBER
- 1. PURPOSE 4
- 2.
SUMMARY
OF RESULTS 4
- 3. REFERENCES 6 4 ASSUMPTIONS 7 5 DESIGN INPUT 12
- 6. OVERALL APPROACH AND METHODOLOGY 16
- 7. CALCULATIONS 16
- 8. APPENDICES Appendix A - RADTRAD Nuclide Inventory File fhadefa.nif 19 Appendix B - RADTRAD Timing & Release Fraction File FHA Update 6-09-05.rft 29 Appendix C - RADTRAD Output File OA.psf 31 Appendix D - RADTRAD Output File OB.psf 50 Appendix E - RADTRAD Output File OC.psf 69 Appendix F - RADTRAD Output File OD.psf 88 Appendix G - RADTRAD Output File OE.psf 107 Appendix H - RADTRAD Output File OF.psf 126 Appendix I - RADTRAD Output File OG.psf 145 Appendix J - RADTRAD Output File OG.psf 164 Appendix K - RADTRAD Output File OG.psf 183
i CALCULATION NOC-1 101-900-EOOO-083 § REV. No. 2 I PAGE NO.3 This revision (Revision 2) provides the following:
- In accordance with Technical Specification Change Request No. 326: Elimination of Containment Equipment Hatch Closure During Refueling, release from the reactor building equipment hatch is being re-evaluated in order to support an NRC Request for Additional Information (RAI).
- New atmospheric dispersion factors (X/Qs) have been calculated using the guidance provided in Regulatory Guide 1.194. These XIQs are applied to the FHA analysis for revised dose consequences to control room operators.
- Table of Contents page numbers were updated to match the new format (CC-AA-309-1001, Rev. 2).
- Reference 3.18 and 3.19 were added.
- Appendix B was revised to reflect twice the iodine and noble gas release fractions minus the cesium.
- New RADTRAD pages were added to replace those from Revision 1.
- Attachment A was removed (Design inputs included in Section 5)
I CALCULATION NOC-l 101-900-EOOO-083 l REV. No. 2 l PAGE NO. 4
1.0 PURPOSE
The purpose of this analysis is to determine the Exclusion Area Boundary (EAB), Low Population Zone (LPZ) and Control Room (CR) doses due to a Fuel Handling Accident Occurring in the Reactor Building With Personnel and/or Equipment Hatch Air Lock Doors Opened.
2.0 Results Summary The results of fuel handling accident occurring in the reactor building with personnel and/or equipment hatch air lock doors opened.
FHA Occurring In Reactor Building Post-FHA TEDE Dose (Rem)
Control EAB LPZ
_______ Room ___ _ _
Calculated 1.12E+00 4.49E+00 7.87E-01 Dose Allowable 5.OOE+00 6.30E+00 6.30E+00 Dose I Significant assumptions used in this analysis:
- Reactor building airlocks and equipment hatch remain open for the duration of the accident.
- No reactor building filtration is assumed during the accident.
- All activity released to the environment within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> using a flow rate of 165,780 cfm which bounds the maximum RB purge vent flow of 50,000 cfm.
- A control room unfiltered inleakage of 1,000 cfm is assumed which bounds the value measured using a tracer gas test..
- A sensitivity evaluation regarding control room HVAC flows (intake and recirculation) was performed to consider the worst combination of the flow tolerances (10% low recirc flow, 10%low intake flow). A summary table and associated RADTRAD outputs are included.
This is a change from the previous analysis that used nominal flow rates.
- A 30-minute delay in placing CR HVAC system into the radiation mode is assumed
- 208 fuel rods are assumed to be damaged.
Previously, only the iodine fractions were doubled.
- The highest calculated control room X/Q for any of the containment openings is used is used.
I CALCULATION NOC-I 101-900-EOOO-083 I REV. No. 2 lPAGE NO. l HVAC Flow Tolerance Sensitivity Evaluation RADTRAD Run OA OB OC OD OE OF OG OH 01 CR Recirc, cfm 25,200 l 25,200 - 25,200 28,000 28,000 28,000 30,800 30,800 - 30,800 CR Filtered Intake, cfm 8,800 8,000 7,200 8,800 8,000 7,200 8,800 8,000 7,200 CR Unfiltered Inleakage, cfm 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000 CR Exhaust, cfm 9,800 9,000 8,200 9,800 9,000 8,200 9,800 9,000 8,200 CR Dose, Rem TEDE 1.1038 1.1111 1.1188 1.0833 1.0895 1.0961 1.0655 1.0708 1.0765
Conclusion:
Based on the sensitivity runs from RADTRAD (see Appendix C through I), the worst-case flow combination is when both the recirc and intake flows are 10% less.
CALCULATION NOC-1101-900-EOOO-083 REV. No. 2 PAGE NO. 6 3.0 References 3.1. U.S. NRC Regulatory Guide 1.183, Alternative Radiological Source Terms for Evaluating Design Basis Accidents at Nuclear Power Reactors, July 2000.
3.2 S.L. Humphreys et al., "RADTRAD: A Simplified Model for Radionuclide Transport and Removal and Dose Estimation," NUREG/CR-6604, USNRC, April 1998.
3.3 USNRC, "Laboratory Testing of Nuclear-Grade Activated Charcoal," NRC Generic Letter 99-02, June 3, 1999.
3.4 AmerGen Calculation C-1 101-202-E620-415, Rev. 2, 'TMI-1 Isotopic Core Inventory," R. Jaffa, November 10, 2000 3.5 Vendor Calculation G98TM-4L, Rev 0, "PLG Inc. Report dated July 23, 1998 ACCIDENT X/Q VALUES FOR TMI-1" 3.6 TMI I Technical Specifications:
3.6.1 Specification TS 3.8.6 3.6.2 Specification TS 3.8.10 3.6.3 Specification TS 3.15.1.2.a 3.6.4 Specification TS 3.15.1.2.b 3.7 GPUN Calculation C-1 101-826-E540-020, Rev 2,"Atmospheric Transport X/Q's Using ARCON96 Code - Control Room Habitability" 3.8 AmerGen Calculation No. C-1 101-826-E260-023, Rev 2, "TMI-1 Control Building Emergency Envelope Free Air Volume."
3.9 Control Room Envelope Inleakage Testing at TMI Nuclear Station Final Report, November 13, 2000 3.10 Function Test No. 826.05; Control Room Ventilation Configuration For Tracer Gas Testing, Rev.
0, 8/19/00 through 8/21/00 3.11 TMI-1 UFSAR Section 14.2.2.1.b.1 3.12 10 CFR 50.67, "Alternate Source Term."
3.13 GPUN Calculation C-i 101-900-EOOO-072, Rev 2, "TMI-1 Dose Consequences from MHA with 15 gph ECCS Leakage."
3.14 Validation of TMI-1 Design Input Parameters Used In Post-FHA Licensing Basis Analysis (Attachment A).
3.15 GPUN Calculation C-1 101-252-5412-012, Rev 0, "Radiological Analysis of FHA and SFCDA for 5.0 w/o, 60 GWD/MTU Fuel."
3.16 Federal Guidance Report 11, "Limiting Values of Radionuclide Intake and Air Concentration and Dose Conversion Factors for Inhalation, Submersion, and Ingestion."
I CALCULATION NOC-1 10I-900-EOOO-083 I REV. No. 2 l PAGE NO. 7 l 3.17 Exelon "Verification & Validation of RADTRAD Computer Code 3.18 AmerGen Calculation C-i 101-202-E620-437, Revision 0, "Fission Product Release Fractions for Hi Burnup, Hi Power Fuel to Support TMI-1 LAR No. 249" 3.19 AmerGen Calculation C-i 101-826-E410-030, Revision 0, "Additional Onsite X/Q Values for Alternative Source Term Application" 4.0 Assumptions Assumptions for Evaluating the Radiological Consequences of a Fuel Handling Accident (FHA)
The assumptions in these sections are acceptable for evaluating the radiological consequences of FHA.
These assumptions supplement the guidance provided in Regulatory Guide 1.183 (Ref. 3.1).
Source Term Assumptions 4.1 Per Reference 3.1, Regulatory Position 3.2, for non-LOCA events, the fractions of the core inventory assumed to be in the gap for the various radionuclides are given in Table 3 of RG 1.183.
For this analysis, the release fractions from Table 3 are incorporated in the design input Table 2 in conjunction with the fission product inventory calculated in Table 1 with the maximum core radial peaking factor of 1.70 consistent with the existing licensing basis.
Additionally, there have previously been approximately 8 to 16 fuel assemblies evaluated to exceed the RG 1.183 footnote 11 value of 6.3 kWMft peak rod average power for bumups exceeding 54 GWD/MTU. The current core design however, has no such assemblies. Therefore, to account for such assemblies in the future, the RG 1.183 Table 3 gap release fractions for noble gas and halogens is doubled for conservatism, even though an ANSI/ANS Standard 5.4 analysis (Reference 3.18) indicates lower release fractions.
4.2 Per Reference 3.1, Appendix B, Regulatory Position B.1.1, the number of fuel rods damaged during the accident should be based on a conservative analysis that considers the most limiting case. This analysis should consider parameters such as the weight of the dropped heavy load or the weight of a dropped fuel assembly (plus any attached handling grapples), the height of the drop, and the compression, torsion, and shear stresses on the irradiated fuel rods. Damage to adjacent fuel assemblies, if applicable (e.g., events over the reactor vessel), should be considered.
For the purpose of this analysis, all fuel rods (208) in one assembly are assumed to be damaged consistent with the existing licensing basis.
4.3 Per Reference 3.1, Appendix B, Regulatory Position B.1.2, the fission product release from the breached fuel in this analysis is based on Regulatory Position 3.2 and the estimate of the number of fuel rods breached.
Core Inventory The inventory of fission products in the reactor core and available for gap release from damaged fuel is based on the maximum power level of 2,619 MWt corresponding to current fuel
ICALCULATION NOC-I 101-900-EOOO-083 REV. No. 2 I PAGE NO. 8 enrichment and fuel bumup, which is 1.02 times the current licensed rated thermal power of 2,568 MWt. All of the gap activity in the damaged rods is assumed to be instantaneously released.
Radionuclides included are xenons, kryptons, and iodines. The cesiums, and rubidiums are assumed to be retained by the water in the fuel pool or reactor cavity (The gap activity is shown in Table 1 of Design Input 5.3.1.2. It is further assumed that irradiated fuel shall not be removed from the reactor until the unit has been sub-critical for at least 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> (TS 3.8.10).
4.4 Timing of Release Phase Per Reference 3.1, Regulatory Position 3.3, for non-LOCA DBAs in which fuel damage is projected, the release from the fuel gap and the fuel pellet is assumed to occur instantaneously with the onset of the projected damage.
4.5 Chemical Form Per Reference 3.1, Appendix B, Regulatory Position B.1.3, the chemical form of radioiodine released from the fuel to the surrounding water is assumed to be 95% cesium iodide (CsI), 4.85 percent elemental iodine, and 0.15 percent organic iodide. The CsI released from the fuel is assumed to completely dissociate in the pool water. Because of the low pH of the pool water, the iodine re-evolves as elemental iodine. This is assumed to occur instantaneously.
4.6 Water Depth If the depth of water above the damaged fuel is 23 feet or greater, the decontamination factors for the elemental and organic species are 500 and 1, respectively, giving an overall effective decontamination factor of 200 (i.e., 99.5% of the total iodine released from the damaged rods is retained by the water). This difference in decontamination factors for elemental (99.85%) and organic iodine (0.15%) species results in the iodine above the water being composed of 57%
elemental and 43% organic species (Ref. 3.1, RGP B.2). The depth of water above damaged fuel for a fuel handling accident at TMI-1 is greater than 23 feet. Therefore, treatment is per Ref. 3.1, RGP B.2.
4.7 Noble Gases The retention of noble gases in the water in the fuel pool or reactor cavity is negligible (i.e.,
decontamination factor of 1). Particulate radionuclides are assumed to be retained by the water in the fuel pool or reactor cavity (i.e., infinite decontamination factor) (Ref. 3.1, RGP B.3).
Fuel Handling Accidents Within Containment For fuel handling accidents postulated to occur within the containment, the following assumptions are acceptable to the NRC staff (Ref. 3.1, RGP B.5).
4.8 If the containment is isolated during fuel handling operations, no radiological consequences need to be analyzed. This analysis assumes that the airlock doors and equipment hatch remain open.
4.9 Since the containment is open during fuel handling operations (personnel air lock, emergency airlock, or equipment hatch is open) the radioactive material that escapes from the reactor cavity pool to the containment is released to the environment over a 2-hour time period.
4.10 A reduction in the amount of radioactive material released from the containment by ESF filter systems may be taken into account provided that these systems meet the guidance of Regulatory
CALCULATION NOC-I 101-900-EOOO-083 I REV. No. 2 l PAGE NO. 9 l Guide 1.52 and Generic Letter 99-02 (Ref. 3.3). Delays in radiation detection, actuation of the ESF filtration system, or diversion of ventilation flow to the ESF filtration system should be determined and accounted for in the radioactivity release analyses. No ESF filtration is credited in this analysis prior to activity being released to the environment.
4.11 Credit for dilution or mixing of the activity released from the reactor cavity by natural or forced convection inside the containment may be considered on a case-by-case basis. Such credit is generally limited to 50% of the containment free volume. Evaluation should consider the magnitude of the containment volume and exhaust rate, the potential for bypass to the environment, the location of exhaust plenums relative to the surface of the reactor cavity, recirculation ventilation systems, and internal walls and floors that impede stream flow between the surface of the reactor cavity and the exhaust plenums. In this evaluation, the activity is assumed to mix with 100% of containment volume to calculate a hypothetical maximum release rate to remove almost all activity distributed in the containment volume. The volumetric release rate is dependent on the duration of release and the remaining fraction of activity in the containment volume. Therefore, the release rate becomes independent of the mixing process.
Offsite Dose Consequences The following guidance is used in determining the TEDE for a maximum exposed individual at EAB and LPZ locations:
4.12 The offsite dose is determined in TEDE, which is the sum of the committed effective dose equivalent (CEDE) from inhalation and the deep dose equivalent (DDE) from external exposure from all radionuclides that are significant with regard to dose consequences and the released radioactivity (Ref. 3.1, RGP 4.1.1).
4.13 The offsite dose analysis is performed using the RADTRAD3.02 code (Ref. 3.2), which uses the Committed Effective Dose (CED) Conversion Factors for inhalation, submersion, and ingestion from Reference 3.11 (Ref 3.1 RGP 4.1.2).
4.14 Since RADTRAD3.02 calculates Deep Dose Equivalent (DDE) using whole body submergence in semi-infinite cloud with appropriate credit for attenuation by body tissue, the DDE can be assumed nominally equivalent to the effective dose equivalent (EDE) from external exposure.
Therefore, the code uses DDE in lieu of EDE in determining TEDE. The dose conversion factors are obtained from Reference 3.16 (Ref 3.1 RGP 4.1.4).
4.15 The TEDE for the EAB receptor location is determined for two-hour period following the start of the radioactivity release and used in determining compliance with the dose acceptance criteria in Reference 3.1, RGP 4.4 Table 6.
EAB Dose Acceptance Criteria: 6.3 Rem TEDE 4.16 TEDE is determined for the most limiting receptor at the outer boundary of the low population zone (LPZ) and is used in determining compliance with the dose criteria in Reference 3.1, RGP 4.4 Table 6.
LPZ Dose Acceptance Criteria: 6.3 Rem TEDE 4.17 No correction is made for depletion of the effluent plume by deposition on the ground (Ref 3.1, RGP 4.1.7).
CALCULATION NOC-1 101-900-EOOO-083 l REV. No. 2 TPAGE NO. 10 4.18 The breathing rates used for persons at offsite locations (Ref. 3.1, RGPs 4.1.3 & 4.4), which are incorporated in design input 5.5.3.
Control Room Dose Consequences The following guidance is used in determining the TEDE for maximum exposed individuals located in the control room:
4.19 The CR TEDE analysis considers the following sources of radiation that will cause exposure to control room personnel (Ref 3.1, RGP 4.2.1):
- Contamination of the control room atmosphere by the intake or infiltration of the radioactive material contained in the post-accident radioactive plume released from the facility (via CR air intake),
- Contamination of the control room atmosphere by unfiltered inleakage,
- Radiation shine from the external radioactive plume released from the facility (external airborne cloud),
- Radiation shine from radioactive material in the reactor containment (containment shine dose),
Radiation shine from radioactive material in systems and components inside or external to the control room envelope, e.g., radioactive material buildup in recirculation filters (CR filter shine dose).
Note: The external airborne cloud dose, containment shine dose, and CR filter shine dose due to FHA are insignificant compared to those due to a LOCA (see the core release fractions for LOCA and non-LOCA design basis accidents in Tables 2 and 3 of Reference 3.1),
therefore, since these doses are not significant, they are not evaluated for the FHA.
4.20 The radioactivity releases and radiation levels used in evaluating the control room dose are determined using the same source term, transport, and release assumptions used for determining the exclusion area boundary (EAB) and the low population zone (LPZ) TEDE values (Ref 3.1, RGP 4.2.2).
4.21 The occupancy and breathing rate of the maximum exposed individuals present in the control room are incorporated in design inputs 5.4.7 & 5.4.8 (Ref. 3.1, RGP 4.2.6).
4.22 10 CFER 50.67 (Ref 3.12 establishes the following radiological criterion for the control room.
CR Dose Acceptance Criteria: 5 Rem TEDE (50.67(b)(2)(iii))
4.23 Credit for engineered safety features that mitigate airborne activity within the control room is taken for control room isolation or pressurization, intake or recirculation filtration. Refer to SRP 6.5.1, "ESF Atmospheric Cleanup System. The control room design is often optimized for the DBA LOCA and the protection afforded for other accident sequences may not be as advantageous. In most designs, control room isolation is actuated by engineered safeguards feature (ESF) signals or radiation monitors (RMs). In some cases, the ESF signal is effective only for selected accidents, placing reliance on the RMs. Several aspects of RMs can delay the isolation, including the delay for activity to build up to concentrations equivalent to the alarm
CALCULATION NOC-l 101-900-EOOO-083 l REV. No. 2 l PAGE NO. 11 setpoint and the effects of different radionuclide accident isotopic mixes on monitor response. To eliminate the effects of RM detection delays, the TMI-1 control room is conservatively assumed to be isolated manually by CR operator 30 minutes after an accident.
5.0 Design Inputs:
5.1 General Considerations 5.1.1 Analvsis Oualitv The design basis accidents postulated and analyzed to provide a conservative set of assumptions to demonstrate the performance of one or more aspects of the facility design to protect the control room operator and the health and safety of general public. The guidance in the Regulatory Guide 1.183 (Ref.
3.1) and plant-specific design input compatible for the AST and TEDE dose criteria are incorporated in this analysis, which provides the selected sets of assumptions, design inputs, and models. This assures an appropriate and prudent safety margin against unpredicted events in the course of an accident and compensates for large uncertainties in facility parameters, accident progression, radioactive material transport, and atmospheric dispersion.
5.1.2 Credit for Engineered Safeguard Features Credit is taken only for accident mitigation features that are classified as safety-related, are required to be operable by technical specifications, are powered by emergency power sources, and are either automatically actuated or, in limited cases, have actuation requirements explicitly addressed in emergency operating procedures. The CR emergency filtration system including the charcoal and HEPA filters is a safety related system, which is credited for dose mitigation. The values of charcoal and HEPA filter efficiencies (90% and 99%, respectively) are obtained from the applicable technical specifications (see design inputs 5.4.5 & 5.4.6).
5.1.3 Assignment of Numeric Input Values The numeric values that are chosen as inputs to the analyses required by 10 CFR 50.67 (Ref. 3.12) are compatible to AST and TEDE dose criteria and selected with the objective of maximizing the postulated dose. As a conservative alternative, the limiting value applicable to each portion of the analysis is used in the evaluation of that portion. For parameters addressed by technical specifications, the values used in the analysis are those specified in the technical specifications. The effects of HVAC flow tolerances was evaluated.
5.1.4 Applicability of Prior Licensing Basis AST is currently licensed at TMI-1. This evaluation expands the original analysis to include an open containment equipment hatch during fuel handling. The analysis in this calculation ensures that analysis assumptions, design inputs, and methods are compatible with the ASTs and the TEDE criteria.
5.1.5 Meteorolozy Considerations Atmospheric dispersion values (X/Q) for the EAB, the LPZ, and the control room that are approved by the Staff in previous licensing proceedings are used in performing the radiological analyses identified in this calculation (Refs 3.5 & 3.7). The atmospheric dispersion factors for the CR have been recalculated (Reference 3.19) using the ARCON96 computer code sponsored by the NRC and the guidance in RG 1.194.
CALCULATION NOC-I 101-900-EOOO-083 REV. No. 2 I PAGE NO. 12 5.2 Accident-Specific Design Inputs/Assumptions The design inputs/assumptions utilized in the EAB, LPZ, and CR habitability analyses are listed in the following sections. The design inputs are compatible with the AST and TEDE dose criteria and assumptions are consistent with those identified in Regulatory Position 3 and Appendix B of RG 1.183 (Ref. 3.1). The design inputs and assumptions in the following sections represent the as-built design of the plant.
Figure 1: FHA Occurring In Reactor Building With Hatch Opened RADTRAD Nodalization 5.3 FHA Occurring In Reactor Building With Hatch Doors Opened Design Input Parameters Design Input Parameter Value Assigned Reference 5.3.1 Source Term 5.3.1.1 Power Level 2,619 MWt (2,568 x 1.02 = 3.4, Page 2 2,619) 5.3.1.2 Isotopic Core Inventory See Below 3.4, Table 1 Table -
- Core Invzentory - ___-_-_-__-
Isotope Activity Isotope Activity Isotope Activity KR 85 1.05E+06 1132 1.03E+08 XE133 1.50E+08 KR 85M 2.33E+07 1133 1.50E+08 XE135 5.51E+07 KR 87 4.60E+07 1134 1.66E+08 XE135M 2.85E+07
CALCULATION NOC-1 101-900-EOOO-083 REV. No. 2 I PAGE NO. 13 KR 88 6.48E+07 1135 1.39E+08 CS134 1.71E+07 RB 86 1.64E+05 XE-131M 7.17E+05 CS136 4.74E+06 1131 7.15E+07 XE-133M 4.56E+06 CS137 1.15E+07 5.3.1.3 Radionuclide Release Fractions. See corrected RADTRAD RFT File in Appendix B
. . ' 'Table2 - -
Fraction of Fission Product Inventory in Gap Note: Also refer to Appendix B, "RADTRAD Timing & Release Fraction File FHA Update 6 05.rft" Group Fraction 3.1, RGP 3.2, Table 3 I-131 0.16 Note: RG 1.183 fractions doubled in Kr-85 0.20 this analysis for conservatism.
Other Noble Gases 0.10 Other Halogens 0.10 Alkali Metals N/A - Retained in water 5.3.1.4 Radionuclide Composition
- i,
.-. ' -. Table3 Group Elements 3.1, RGP 3.4, Table 5 Noble Gases Xe, Kr Halogens I, Br Alkali Metals Cs, Rb 5.3.1.5 Radial Peaking Factor 1.7 3.15, Page 2 5.3.1.6 Damaged Fuel Rods 208 3.15, Page 2 5.3.1.7 Number of Fuel 177 3.15, Page 4 Assemblies In Core 5.3.1.8 Irradiated Fuel Decay 72 hrs 3.6.2
I CALCULATION NOC-1 101-900-EOOO-083 I REV. No. 2 I PAGE NO. 14 CONTROL ROOM V = 250,000 ft3 HEPA Filter il = 99%
Charcoal Filter lTj, 0 = 90%
Figure 2 - TMI-1 Control Room RADTRAD Nodalization Design Input Parameter l 5.4 Control Room Model Parameters _
5.4.1 CR Volume _250,000 5.4.2 CREV System Flow Rate -18,000 cfm +/- IO%
CALCULATION NOC-I10I-900-EOOO-083 I REV. No. 2 - PAGE NO. 15 5.4.3 CR Min Recirc Flow Rate 28,000 cfm +/- 10% 3.9 & 3.10 5.4.4 CR Unfiltered Inleakage 1,000 cfm 3.9 & 3.10 5.4.5 CR Charcoal Filter 90% 3.6.4 Efficiencies 5.4.6 CR HEPA Filter Efficiency 99% used in analysis (99.95% in 3.6.3 TS) 5.4.7 CR Occupancy Factors
- :-;- .- Table 4,;----:--: - !i Time (Hr) % 3.1, RGP 4.2.6 0-24 100 24-96 60 96-720 40 Design Input Parameter Value Assigned Reference 3
5.4.8 CR Breathing Rate (m /sec) 3.5E-04 3.1, RGP 4.2.6 5.4.9 CR Atmospheric Dispersion Factors (X/Qs)
- ; -l--- i-;l -; 1--
Table S;-;;- - -;f K-; -;
Time (Hr) XIQ (sec/m 3) 0-2 5.34E-04 3.19, page 8 2-8 3.10E-04 8-24 1.36E-04 24-96 9.70E-05 96-720 6.02E-05 5.5 Site Boundary Release Model Parameters 5.5.1 EAB Atmospheric 8.OE-04 3.5, Page 6 3
Dispersion Factor (X/Q) (sec/m ) I__
5.5.2 LPZ Atmospheric Dispersion Factors (X/Qs)
-___-_-_-__-__-_-_- -_-- Table 6 Time (Hr) X/Q (sec/rm3 ) 3.5, Page 6 0-2 1.4E-04 2-8 6.OE-05 8-24 3.9E-05 24-96 1.6E-05 96-720 4.OE-06 3
5.5.3 Breathing Rate (m /sec) (Ref 3.1, RGP 4.2.6)
-- -- . -- -Table77. i- .. -
Time (Hr) (m3 /sec) 3.1, RGP 4.1.3 0-8 3.5E-04 8-24 1.8E-04 24-720 2.3E-04
CALCULATION NOC-1 101-900-EOOO-083 I REV. No. 2 } PAGE NO. 16 l
- 6. OVERALL APPROACH AND METHODOGOLY Fuel Handling Accident in the Reactor Building With Air Lock Doors and equipment hatch Opened Activity released from the refueling cavity is uniformly distributed in the entire volume of containment building and released to the environment over a two hour time period such that 99.99% of the activity released from the damaged spent fuel assembly is released to the environment.
The Reference 3.1 Regulatory Position in Appendix B, Section 5.2 allows dilution or mixing of the activity released from the reactor cavity by natural or forced convection inside the containrment. Such credit is limited to 50% of the containment free volume. In this case, the activity is assumed to mix with 100% of containment volume to calculate a hypothetical maximum release rate (165,780 cfm) to remove almost all activity (99.99%) distributed in the containment volume. The volumetric release rate (cfm) is dependent on the duration of release (2.0 Hrs) and remaining fraction of activity in the containment volume (1 - 0.9999 = 0.0001); therefore, the release rate becomes independent of the mixing process.
- 7. CALCULATIONS 7.1 Post-FHA Activity Released in Reactor Building For the FHA in the containment, it is assumed that one peak fuel assembly was damaged with a peaking factor of 1.7. The undecayed noble gas and iodine isotopic activities released in the reactor building from the damaged fuel assembly are calculated in Table 8 below. These isotopic activities in CiIMWt are utilized for modifying the RADTRAD Nuclide Inventory File fharb_def a.nif (see Appendix A).
7.2 TMI-1 Plant Specific Nuclide Inventory File (NIF) For RADTRAD3.02 Input The RADTRAD nuclide inventory file Pwr_defnif establishes the power dependent radionuclide activity in Ci/MWt for the reactor core source term. Since these core radionuclide activities are dependent on the core thermal power level, reload design, and burnup, the nif should be modified based on the plant-specific core inventory. The CiIMWt for the core radionuclides are calculated in Table 8 and the NIF for RADTRAD input are modified accordingly as shown in Appendix A.
7.3 Post-FHA Release Rates The release rate for the source node - Pool to Reactor Building - is calculated such that 99.99% of the activity released into the reactor building is released to the environment in two hours.
A = AO eXt Where; AO = Initial Activity in Source Node A = Final Activity in Source Node X = Removal Rate (Vol/hr) t = Removal Time (hr) = 2.0 hr
CALCULATION NOC-1 101-900-EOOO-083 l REV. No. 2 - PAGE NO. 17 l Assuming that 99.99% of activity is released into the environment, A/AO = 0.0001 Therefore, A/Ao e= '
0.0001 e=2 In (0.0001) = - 2X ln(e)
-9.210=-2X X = -9.210/-2 = 4.605 volume/hr For Reactor Building Release Rate
= 4.605 x 2,160,000 ft3 /hr = 9,946,800ft 3 Ihr x 1/60 hr/min = 165,780 ft3 /min
CALCULATION NOC-1101-900-EOOO-083 I REV. No. 2 1 PAGE NO. 18 Table 8 Post-FHA Activity In Reactor Building - RADTRAD Code Nuclide Inventory File
___ _ __ _ _I ___ ___ I Core Radial Number Activity l Post-FHA Activity In RB Bldg Isotope Initial Peaking Of Fuel In Damaged For RADTRAD Code Inventory Factor Assembly Spent Fuel DF Nuclide Inventory File (Ci) In Core Assembly _
(Ci) (Ci) (Ci/MWt) (CitMWt)
A B C D=A*B/C E F=DtE G=F/2619 G KR 85* 1.05E+06 1.7 177 1.OOE+04 1.0 1.OOE+04 3.833E+00 .7666E+01 KR 85M 2.33E+07 1.7 177 2.24E+05 1.0 2.24E+05 8.538E+01 .8538E+02 KR 87 4.60E+07 1.7 177 4.411E+05 1.0 4.41iE+05 1.686E+02 .1686E+03 KR 88 6.48E+07 1.7 177 6.23E+05 1.0 6.23E+05 2.377E+02 .2377E+03 1131** 7.15E+07 1.7 177 6.87E+05 200.0 3.43E+03 1.311E+00 .2097E+0O 1132 1.03E+08 1.7 177 9.92E+05 200.0 4.96E+03 1.894E+00 .1894E+0I 1133 1.50E+08 1.7 177 1.44E+06 200.0 7.18E+03 2.741E+00 .2741E+0O 1134 1.66E+08 1.7 177 1.60E+06 200.0 7.98E+03 3.048E+00 .3048E+01 1135 1.39E+08 1.7 177 1.34E+06 200.0 6.70E+03 2.556E+00 .2556E+01 XE-131M 7.17E+05 1.7 177 6.89E+03 1.0 6.89E+03 2.629E+00 .2629E+01 XE-133M 4.56E+06 1.7 177 4.38E+04 1.0 4.38E+04 1.672E+01 .1672E+02 XE133 1.50E+08 1.7 177 1.44E+06 1.0 1.44E+06 5.501E+02 .5501E+03 XE135 5.5 1E+07 1.7 177 5.29E+05 1.0 5.29E+05 2.0211E+02 .2021 E+03 XE135M 2.85E+07 1.7 177 2.74E+05 1.0 2.74E+05 1.045E+02 .1045E+03
- KR-85 activity is multiplied by a factor 2 (0.1/0.05) to account for additional fractional release.
- I-131 activity is multiplied by a factor 1.6 (0.08/0.05) to account for additional fractional release.
I CALCULATION NOC-1 101-900-EOOO-083 l REV. No. 2 TPAGE NO. 19 l Appendix A RADTRAD Nuclide Inventory File fharbdef_a.nif EHA Occurring In Reactor Building With Hatch Doors Opened
CALCULATION NOC-1101-900-EOOO-083 I REV. No. 2 l PAGE NO.20_
Nuclide Inventory Name:FHA Occuring In Reactor Building - fharb_def_a.nif TMI-1 Plant Specific Core Inventory (2619 MWth)
Power Level:
0.1000E+01 Nuclides:
60 Nuclide 001:
Co-58 7
0.6117120000E+07 0.5800E+02 0.OOOOE+00 none 0.OOOOE+00 none 0.OOOOE+00 none 0.OOOOE+00 Nuclide 002:
Co-60 7
0.1663401096E+09 0.6000E+02 0.0000E+00 none 0.OOOOE+00 none 0.OOOOE+00 none 0.OOOOE+00 Nuclide 003:
Kr-85 1
0.3382974720E+09 0.8500E+02 0.7666E+01 none 0.OOOOE+00 none 0.0000E+00 none 0.OOOOE+00 Nuclide 004:
Kr-85m 1
0.1612800000E+05 0.8500E+02 0.8538E+02 Kr-85 0.2100E+00 none 0.OOOOE+00 none 0.OOOOE+00 Nuclide 005:
Kr-87 1
0.4578000000E+04 0.8700E+02 0.1686E+03 Rb-87 0.1000E+01 none 0.OOOOE+00 none 0.0000E+00 Nuclide 006:
Kr-88 1
0.1022400000E+05 0.8800E+02 0.2377E+03 Rb-88 0.1000E+01 none 0.OOOOE+00 none O.OOOOE+00 Nuclide 007:
Rb-86 3
0.1612224000E+07 0.8600E+02 0.OOOOE+00 none 0.OOOOE+00 none 0.OOOOE+00
CALCULATION NOC-1 101-900-EOOO-083 l REV. No. 2 1 PAGE NO. 21 none O.OOOOE+0O Nuclide 008:
Sr-89 5
0.4363200000E+07 0.8900E+02 O.OOOOE+00 none O.OOOOE+00 none O.OOOOE+00 none O.OOOOE+00 Nuclide 009:
Sr-90 5
0.918957312OE+09 0.9000E+02 O.OOOOE+00 Y-90 0.1000E+01 none O.OOOOE+00 none O.OOOOE+00 Nuclide 010:
Sr-91 5
0.3420000000E+05 0.9100E+02 O.OOOOE+00 Y-91m 0.5800E+00 Y-91 0.4200E+00 none O.OOOOE+00 Nuclide 011:
Sr-92 5
0.9756000000E+04 0.9200E+02 O.OOOOE+00 Y-92 0.1000E+01 none O.OOOOE+00 none O.OOOOE+00 Nuclide 012:
Y-90 9
0.2304000000E+06 0.9000E+02 O.OOOOE+00 none O.OOOOE+00 none O.OOOOE+00 none O.OOOOE+00 Nuclide 013:
Y-91 9
0.5055264000E+07 0.9100E+02 O.OOOOE+00 none O.OOOOE+00 none O.OOOOE+00 none O.OOOOE+00 Nuclide 014:
Y-92 9
0.1274400000E+05 0.9200E+02 O.OOOOE+00 none O.OOOOE+00 none O.OOOOE+00 none O.OOOOE+00 Nuclide 015:
Y-93 9
0.3636000000E+05
CALCULATION NOC-l 101-900-EOOO-083 l REV. No. 2 1 PAGE NO. 22 0.9300E+02 O.OOOOE+00 Zr-93 0.1000E+01 none O.OOOOE+00 none O.OOOOE+00 Nuclide 016:
Zr-95 9
0.5527872000E+07 0.9500E+02 O.OOOOE+00 Nb-95m 0.7000E-02 Nb-95 O.9900E+00 none O.OOOOE+00 Nuclide 017:
Zr-97 9
0.6084000000E+05 0.9700E+02 O.OOOOE+00 Nb-97m 0.9500E+00 Nb-97 0.5300E-01 none O.OOOOE+00 Nuclide 018:
Nb-95 9
0.3036960000E+07 0.9500E+02 O.OOOOE+00 none O.OOOOE+00 none O.OOOOE+00 none O.OOOOE+00 Nuclide 019:
Mo-99 7
0.2376000000E+06 0.9900E+02 O.OOOOE+00 Tc-99m 0.8800E+00 Tc-99 0.1200E+00 none O.OOOOE+00 Nuclide 020:
Tc-99m 7
0.2167200000E+05 0.9900E+02 O.OOOOE+00 Tc-99 0.1000E+01 none O.OOOOE+00 none O.OOOOE+00 Nuclide 021:
Ru-103 7
0.3393792000E+07 0.1030E+03 O.OOOOE+00 Rh-103m 0.1000E+01 none O.OOOOE+00 none O.OOOOE+00 Nuclide 022:
Ru-105 7
0.1598400000E+05 0.1050E+03 O.OOOOE+00 Rh-105 0.1000E+01 none O.OOOOE+00 none O.OOOOE+00
CALCULATION NOC-I 10I-900-EOOO-083 l REV. No. 2 PAGE NO.23 Nuclide 023:
Ru-106 7
0.3181248000E+08 0.1060E+03 0.OOOOE+00 Rh-106 0.1000E+01 none 0.0000E+00 none O.OOOOE+00 Nuclide 024:
Rh-105 7
0.1272960000E+06 0.1050E+03 0.OOOOE+00 none 0.OOOOE+00 none 0.OOOOE+00 none 0.OOOOE+00 Nuclide 025:
Sb-127 4
0.3326400000E+06 0.1270E+03 0.OOOOE+00 Te-127m 0.1800E+00 Te-127 0.8200E+00 none 0.OOOOE+00 Nuclide 026:
Sb-129 4
0.1555200000E+05 0.1290E+03 0.OOOOE+00 Te-129m 0.2200E+00 Te-129 0.7700E+00 none 0.OOOOE+00 Nuclide 027:
Te-127 4
0.3366000000E+05 0.1270E+03 O.OOOOE+00 none 0.OOOOE+00 none 0.OOOOE+00 none 0.OOOOE+00 Nuclide 028:
Te-127m 4
0.9417600000E+07 0.1270E+03 0.OOOOE+00 Te-127 0.9800E+00 none 0.OOOOE+00 none 0.OO00E+00 Nuclide 029:
Te-129 4
0.4176000000E+04 0.1290E+03 0.OOOOE+00 I-129 0.1000E+01 none 0.OOOOE+00 none 0.OOOOE+00 Nuclide 030:
Te-129m 4
0.2903040000E+07 0.1290E+03
I CALCULATION NOC-110 1-900-EOOO-083 l REV.No. 2 l PAGE NO.24 O.OOOOE+00 Te-129 0.6500E+00 I-129 0.3500E+00 none O.OOOOE+00 Nuclide 031:
Te-131m 4
0.1080000000E+06 0.1310E+03 O.OOOOE+00 Te-131 0.2200E+00 I-131 0.7800E+00 none O.OOOOE+00 Nuclide 032:
Te-132 4
0.2815200000E+06 0.1320E+03 O.OOOOE+00 I-132 0.1000E+01 none O.OOOOE+00 none O.OOOOE+00 Nuclide 033:
I-131 2
0.6946560000E+06 0.1310E+03 0.2097E+01 Xe-131m 0.11OOE-01 none O.OOOOE+00 none O.OOOOE+00 Nuclide 034:
I-132 2
0.8280000000E+04 0.1320E+03 0.1894E+01 none O.OOOOE+00 none O.OOOOE+00 none O.OOOOE+00 Nuclide 035:
I-133 2
0.7488000000E+05 0.1330E+03 0.2741E+01 Xe-133m 0.2900E-01 Xe-133 0.9700E+00 none O.OOOOE+00 Nuclide 036:
1-134 2
0.3156000000E+04 0.1340E+03 0.3048E+01 none O.OOOOE+00 none O.OOOOE+00 none O.OOOOE+00 Nuclide 037:
I-135 2
0.2379600000E+05 0.1350E+03 0.2556E+01 Xe-135m 0.1500E+00 Xe-135 0.8500E+00 none O.OOOOE+00 Nuclide 038:
I CALCULATION NOC- I 101I -900-EOOO-083 I REV. No. 2 . .--
IPAGE NO. 25 1I I CALCULATION No. 2 lO1-900-EOOO-083 I REV.
NOC-1 1PAGENO.25 Xe-133 1
0.4531680000E+06 0.133OE+03 0.5501E+03 none O.OOOOE+00 none O.OOOOE+00 none O.OOOOE+00 Nuclide 039:
Xe-135 1
0.3272400000E+05 0.1350E+03 0.2021E+03 Cs-135 0.1000E+01 none O.OOOOE+00 none O.OOOOE+O0 Nuclide 040:
Cs-134 3
0.6507177120E+08 0.1340E+03 O.OOOOE+00 none O.OOOOE+00 none O.OOOOE+00 none O.OOOOE+00 Nuclide 041:
Cs-136 3
0.1131840000E+07 0.1340E+03 O.OOOOE+00 none O.OOOOE+00 none O.OOOOE+00 none O.OOOOE+00 Nuclide 042:
Cs-137 3
0.9467280000E+09 0.1370E+03 O.OOOOE+00 Ba-137m 0.9500E+00 none O.OOOOE+00 none O.OOOOE+00 Nuclide 043:
Ba-139 6
0.4962000000E+04 0.1390E+03 O.OOOOE+00 none O.OOOOE+00 none O.OOOOE+00 none O.OOOOE+00 Nuclide 044:
Ba-140 6
0.1100736000E+07 0.1400E+03 O.OOOOE+00 La-140 0.1000E+01 none O.OOOOE+00 none O.OOOOE+00 Nuclide 045:
La-140 9
0.1449792000E+06 0.1400E+03 O.OOOOE+00
CALCULATION NOC-I 101-900-EOOO-083 I REV. No. 2 l PAGE NO. 26 none O.OOOOE+0O none O.OOOOE+00 none O.OOOOE+00 Nuclide 046:
La-141 9
0.1414800000E+05 0.1410E+03 O.OOOOE+00 Ce-141 0.1000E+01 none O.OOOOE+00 none O.OOOOE+00 Nuclide 047:
La-142 9
0.5550000000E+04 0.142OE+03 O.OOOOE+00 none O.OOOOE+00 none O.OOOOE+O0 none O.OOOOE+00 Nuclide 048:
Ce-141 8
0.2808086400E+07 0.1410E+03 O.OOOOE+00 none O.OOOOE+00 none O.OOOOE+00 none O.OOOOE+00 Nuclide 049:
Ce-143 8
0.1188000000E+06 0.1430E+03 O.OOOOE+00 Pr-143 0.1000E+01 none O.OOOOE+00 none O.OOOOE+00 Nuclide 050:
Ce-144 8
0.2456352000E+08 0.144OE+03 O.OOOOE+00 Pr-144m 0.1800E-01 Pr-144 0.9800E+00 none O.OOOOE+00 Nuclide 051:
Pr-143 9
0.1171584000E+07
- 0. 1430E+03 O.OOOOE+00 none O.OOOOE+00 none O.OOOOE+O0 none O.OOOOE+00 Nuclide 052:
Nd-147 9
0.9486720000E+06 0.1470E+03 O.OOOOE+00 Pm-147 0.1000E+01 none O.OOOOE+00 none O.OOOOE+00 Nuclide 053:
Np-239
LCALCULATIONNOC-1101-900-EOOO-083 I REV. No. 2 1 PAGE NO.27 8
0.2034720000E+06 0.2390E+03 O.OOOOE+00 Pu-239 0.1000E+01 none O.OOOOE+00 none O.OOOOE+00 Nuclide 054:
Pu-238 8
0.2768863824E+10 0.2380E+03 O.OOOOE+00 U-234 O.1000E+01 none O.OOOOE+00 none O.OOOOE+00 Nuclide 055:
Pu-239 8
0.7594336440E+12 0.2390E+03 O.OOOOE+00 U-235 0.1000E+01 none O.OOOOE+00 none O.OOOOE+00 Nuclide 056:
Pu-240 8
0.2062920312E+12 0.2400E+03 O.OOOOE+00 U-236 0.1000E+01 none O.OOOOE+00 none O.OOOOE+00 Nuclide 057:
Pu-241 8
0.4544294400E+09 0.2410E+03 O.OOOOE+00 U-237 0.2400E-04 Am-241 0.1000E+01 none O.OOOOE+00 Nuclide 058:
Am-241 9
0.1363919472E+11 0.2410E+03 O.OOOOE+00 Np-237 0.1000E+01 none O.OOOOE+00 none O.OOOOE+00 Nuclide 059:
Cm-242 9
0.1406592000E+08 0.2420E+03 O.OOOOE+00 Pu-238 0.1000E+01 none O.OOOOE+00 none O.OOOOE+00 Nuclide 060:
Cm-244 9
0.571508136E+9 0.2440E+03 O.OOOOE+00 Pu-240 0.1000E+01
I CALCULATION NOC-1 101-900-EOOO-083 I REV. No. 2 lPAGE NO.28 none O.OOOOE+00 none O.OOOOE+00 End of Nuclear Inventory File
CALCULATION NOC-10IO-900-EOOO-083 I REV. No. 2 I PAGE NO.29 l Appendix B RADTRAD Timing & Release Fraction File FHA Update 6-09-05.rft
CALCULATION NOC- 101 -900-EOOO-083 l REV. No. 2 1 PAGE NO. 30 Release Fraction and Timing Name: FHA Update 6-09-05.rft RG-1.183, Tables 3 Section 3.2 Duration (h): NON-LOCA Accident chk inventory 0.0036E+00 0.OOOOE+00 0.OOOOE+00 O.OOOOE+00 Noble Gases:
0.1000E+00 0.0000E+00 O.OOOOE+00 0.OOOOE+00 Iodine:
0.1000E+00 0.0000E+00 O.OOOOE+00 0.0000E+00 Cesium:
O.OOOOE+00 O.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Tellurium:
0.OOOOE+00 O.OOOOE+00 0.0000E+00 O.OOOOE+00 Strontium:
0.OOOOE+00 0.0000E+00 0.0000E+00 O.OOOOE+00 Barium:
0.0000E+0 0.0OOOOE+00 0.OOOOE+00 O.OOOOE+00 Ruthenium:
0.0000E+00 0.OOOOE+00 O.OOOOE+00 0.0000E+00 Cerium:
0.OOOOE+00 O.OOOOE+00 0.OOOOE+00 0.0000E+00 Lanthanum:
0.OOOOE+00 O.OOOOE+00 0.0000E+00 0.OOOOE+00 Non-Radioactive Aerosols (kg):
0.OOOOE+00 O.OOOOE+00 0.OOOOE+00 O.OOOOE+00 End of Release File
CALCULATION NOC-1 101-900-EOOO-083 T REV. No. 2 TPAGE NO. 31 Appendix C RADTRAD File OA.psf FHA Occurring In Reactor Building With Hatch Doors Opened CR Recirc Flow: 25,200 cfm CR Filtered Intake Flow: 8,800 cfm CR Unfiltered Inleakage: 1,000 cfm CR Exhaust Flow: 9,800 cfm Two Times Iodine & Noble Gas Release Fractions
CALCULATION NOC-1101-900-EOOO-083 T REV. No. 2 1 PAGE NO. 32 RADTRAD Version 3.02 run on 7/07/2005 at 7:53:39 File information Plant file name = C:\Program Files\U S Nuclear Regulatory Commission\Radtrad\OA.psf Inventory file name = c:\program files\u s nuclear regulatory commission\radtrad\defaults\fharb_def_a.nif Scenario file name = C:\Program Files\U S Nuclear Regulatory Commission\Radtrad\OA.psf Release file name = c:\program files\u s nuclear regulatory commission\radtrad\defaults\fha update 6-9-05.rft Dose conversion file name = c:\program files\u s nuclear regulatory commission\radtrad\defaults\fgrll&12.inp
- t # # #t #t ## #t # # # # #
- #t #t # # #### It #~ # # #
I#I### ####t~ ####t~ # #t #t #t #####~ #t #t #
- # ## # # #I# # #t #
- #I~# #I# # ### #t #tt~~ #
Radtrad 3.02 1/5/2000 TMI-1 FHAIC, Hatch Doors Opened, AST Analysis, CR Charcoal Filter Efficiency 75%., 25,200 cfm Recirc, 8,800 cfm Intake Nuclide Inventory File:
c:\program files\u s nuclear regulatory commission\radtrad\defaults\fharb_def_a.nif Plant Power Level:
2.6190E+03 Compartments:
3 Compartment 1:
Containment 3
2.1600E+06 0
0 0
0 0
Compartment 2:
Environment 2
0.OOOOE+00 0
0 0
0 0
Compartment 3:
Control Room 1
2.5000E+05 0
0 1
0
I CALCULATION NOC-1101-900-EOOO-083 I REV. No. 2 I PAGE NO.33 0
Pathways:
4 Pathway 1:
Containment to Environment 1
2 2
Pathway 2:
Control Room Air Intake 2
3 2
Pathway 3:
Control Room Unfiltered Inleakage 2
3 2
Pathway 4:
Control Room Exhaust to Environment 3
2 2
End of Plant Model File Scenario Description Name:
Plant Model Filename:
Source Term:
1 1 1.0000E+00 c:\program files\u s nuclear regulatory commission\radtrad\defaults\fgrll&12.inp c:\program files\u s nuclear regulatory commission\radtrad\defaults\fha update 6 05.rft 7.2000E+01 0
O.OOOOE+00 5.7000E-01 4.3000E-01 1.0000E+00 Overlying Pool:
0 O.0000E+00 0
0 0
0 Compartments:
3 Compartment 1:
0 1
0 0
0 0
0 0
0 Compartment 2:
0 1
0 0
0 0
0 0
0 Compartment 3:
1
I CALCULATION NOC-I101-900-EOOO-083 I REV. No. 2 1 PAGE NO.34 1
0 0
0 0
1 2.5200E+04 3
7.2000E+01 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 7.2500E+01 9.9000E+01 7.5000E+01 7.5000E+01 7.9200E+02 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 0
0 Pathways:
4 Pathway 1:
0 0
0 0
0 1
3 7.2000E+01 1.6580E+05 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 7.4000E+01 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 7.9200E+02 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 0
0 0
0 0
0 Pathway 2:
0 0
0 0
0 1
3 7.2000E+01 4.OOOOE+03 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 7.2500E+01 8.8000E+03 9.9000E+01 7.5000E+01 7.5000E+01 7.9200E+02 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 1.OOOOE+00 0
0 0
0 0
0 Pathway 3:
0 0
0 0
0 1
2 7.2000E+01 1.OOOOE+03 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 7.9200E+02 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 0
0 0
0 0
0 Pathway 4:
0 0
I CALCULATION NOC-1101-900-EOOO-083 I REV. No. 2 l PAGE NO.35 0
0 0
1 3
7.2000E+01 5.0000E+03 O.OOOOE+00 O.OOOOE+00 O.OOOOE+0O 7.2500E+01 9.8000E+03 1.OOOOE+02 1.OOOOE+02 1.OOOOE+02 7.9200E+02 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 0
0 0
0 0
0 Dose Locations:
3 Location 1:
Exclusion Area Boundary 2
1 2
7.2000E+01 8.OOOOE-04 7.2000E+02 O.OOOOE+00 1
2 7.2000E+01 3.5000E-04 7.2000E+02 O.OOOOE+OO 0
Location 2:
Low Population Zone 2
1 6
7.2000E+01 1.4000E-04 7.4000E+01 6.0000E-05 8.OOOOE+01 3.9000E-05 9.6000E+01 1.6000E-05 1.6800E+02 4.OOOOE-06 7.9200E+02 O.OOOOE+00 1
4 7.2000E+01 3.5000E-04 8.OOOOE+01 1.8000E-04 9.6000E+01 2.30OOE-04 7.9200E+02 O.OOOOE+O0 0
Location 3:
Control Room 3
0 1
2 7.2000E+01 3.5000E-04 7.9200E+02 O.OOOOE+OO 1
4 7.2000E+O1 1.OOOOE+O0 9.6000E+01 6.OOOOE-01 1.6800E+02 4.OOOOE-01 7.9200E+02 O.OOOOE+0O Effective Volume Location:
1 6
7.2000E+01 5.3400E-04 7.4000E+01 3.1000E-04 8.0000E+01 1.3600E-04 9.6000E+01 9.7000E-05 1.6800E+02 6.0200E-05
CALCULATION NOC-1 101-900-EOOO-083 l REV. No. 2 l PAGE NO.36 l 7.9200E+02 O.OOOOE+00 Simulation Parameters:
6 7.2000E+O1 l.OOOOE-01 7.4000E+01 5.OOOOE-01 8.0000E+01 1.OOOOE+O0 9.6000E+01 2.0000E+00 1.6800E+02 4.OOOOE+00 7.9200E+02 O.OOOOE+00 Output Filename:
C:\Program Files\U S Nuclear Regulatory Commission\Radtrad\OA.o4 1
1 1
0 0
End of Scenario File RADTRAD Version 3.02 run on 7/07/2005 at 7:53:39 Plant Description Number of Nuclides = 60 Inventory Power = l.0000E+00 MWth Plant Power Level = 2.6190E+03 MWth Number of compartments = 3 Compartment information Compartment number 1 (Source term fraction 1.OOOOE+00
)
Name: Containment Compartment volume = 2.1600E+06 (Cubic feet)
Pathways into and out of compartment 1 Pathway to compartment number 2: Containment to Environment Compartment number 2 Name: Environment Pathways into and out of compartment 2 Pathway to compartment number 3: Control Room Air Intake Pathway to compartment number 3: Control Room Unfiltered Inleakage Pathway from compartment number 1: Containment to Environment Pathway from compartment number 3: Control Room Exhaust to Environment Compartment number 3 Name: Control Room Compartment volume = 2.5000E+05 (Cubic feet)
Removal devices within compartment:
Filter(s)
Pathways into and out of compartment 3 Pathway to compartment number 2: Control Room Exhaust to Environment Pathway from compartment number 2: Control Room Air Intake Pathway from compartment number 2: Control Room Unfiltered Inleakage Total number of pathways = 4 RADTRAD Version 3.02 run on 7/07/2005 at 7:53:39
CALCULATION NOC-1101-900-EOOO-083 I REV. No. 2 1PAGE NO.37 l Scenario Description Time between shutdown and first release = 7.2000E+01 (Hours)
Radioactive Decay is enabled RELEASENAME = RG-1.183, Tables 3 Section 3.2 Release Fractions and Timings GAP EARLY IN-VESSEL 0.0036 hrs 0.0000 hrs NOBLES 1.0000E-01 0.0000E+00 IODINE 1.0000E-01 0.0000E+00 CESIUM 0.OOOOE+00 0.0000E+00 TELLURIUM 0.0000E+00 0.0000E+00 STRONTIUM 0.0000E+00 0.0000E+00 BARIUM 0.0000E+00 0.0000E+00 RUTHENIUM 0.OOOOE+00 0.OOOOE+00 CERIUM 0.OOOOE+00 0.OOOOE+00 LANTHANUM 0.OOOOE+00 0.OOOOE+00 Iodine fractions Aerosol 0.OOOOE+00 Elemental 5.70OQE-01 Organic 4.3000E-01 COMPARTMENT DATA Compartment number 1: Containment Compartment number 2: Environment Compartment number 3: Control Room Compartment Filter Data Time (hr) Flow Rate Filter Efficiencies (%)
(cfm) Aerosol Elemental Organic 7.2000E+01 2.5200E+04 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 7.2500E+01 2.5200E+04 9.9000E+01 7.5000E+01 7.5000E+01 7.9200E+02 2.5200E+04 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 PATHWAY DATA Pathway number 1: Containment to Environment Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)
(cfm) Aerosol Elemental Organic 7.2000E+01 1.6580E+05 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 7.4000E+01 0.0000E+00 0.OOOOE+00 0.0000E+00 0.OOOOE+00 7.9200E+02 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Pathway number 2: Control Room Air Intake Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)
(cfm) Aerosol Elemental Organic 7.2000E+01 4.OOOOE+03 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 7.2500E+01 8.8000E+03 9.9000E+01 7.5000E+01 7.5000E+01 7.9200E+02 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 1.OOOOE+00 Pathway number 3: Control Room Unfiltered Inleakage Pathway Filter: Removal Data
CALCULATION NOC-I 101-900-EOOO-083 I REV. No. 2 T PAGE NO. 38 Time (hr) Flow Rate Filter Efficiencies C%)
(cfm) Aerosol Elemental Organic 7.2000E+01 1.OOOOE+03 O.OOOOE+00 0.OOOOE+00 O.OOOOE+00 7.9200E+02 0.00OOE+00 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 Pathway number 4: Control Room Exhaust to Environment Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)
(cfm) Aerosol Elemental Organic 7.2000E+01 5.OOOOE+03 0.OOOOE+00 0.OOOOE+00 O.OOOOE+00 7.2500E+01 9.8000E+03 1.0000E+02 1.0000E+02 1.OOOOE+02 7.9200E+02 O.OOOOE+00 O.OOOOE+00 0.OOOOE+00 O.OOOOE+00 LOCATION DATA Location Exclusion Area Boundary is in compartment 2 Location X/Q Data Time (hr) X/Q (s
- mA-3) 7.2000E+01 8. OOOOE-04 7.2000E+02 0.OOOOE+O0 Location Breathing Rate Data Time (hr) Breathing Rate (mA3
- secA-1) 7.2000E+01 3.5000E-04 7.2000E+02 0.OOOOE+00 Location Low Population Zone is in compartment 2 Location X/Q Data Time (hr) X/Q (s
- m'-3) 7.2000E+01 1.4000E-04 7.4000E+01 6.OOOOE-05 8.OOOOE+01 3.9000E-05 9.6000E+01 1.6000E-05 1.6800E+02 4.OOOOE-06 7.9200E+02 0.OOOOE+00 Location Breathing Rate Data Time (hr) Breathing Rate (mA3
- sec^-1) 7.2000E+01 3.5000E-04 8.OOOOE+01 1.8000E-04 9.6000E+01 2.30OOE-04 7.9200E+02 0.OOOOE+00 Location Control Room is in compartment 3 Location X/Q Data Time (hr) X/( (s
- m^-3) 7.2000E+01 5.3400E-04 7.4000E+01 3.1000E-04 8.OOOOE+01 1.3600E-04 9.6000E+01 9.70O0E-05 1.6800E+02 6.0200E-05 7.9200E+02 O.OOOOE+00 Location Breathing Rat:e Data Time (hr) BrEeathing Rate (m^3
- secA-1) 7.2000E+01 3.5000E-04 7.9200E+02 O.OOOOE+00 Location Occupancy Facctor Data Time (hr) Occcupancy Factor 7.2000E+01 1.OOOOE+00 9.6000E+01 6.OOOOE-01 1.6800E+02 4.OOO0E-01 7.9200E+02 0.OOOOE+00
CALCULATION NOC-110I-900-EOOO-083 REV. No. 2 PAGE NO.39 USER SPECIFIED TIME STEP DATA - SUPPLEMENTAL TIME STEPS Time Time step 0.OOOOE+00 1.0000E-01 2.OOOOE+00 5.OOOOE-01 8.OOOOE+00 1.OOOOE+00 2.4000E+01 2.OOOOE+00 9.6000E+01 4.OOOOE+00 7.2000E+02 0.OOOOE+00 RADTRAD Version 3.02 run on 7/07/2005 at 7:53:39 ftftftftft ftftftft# #
ft ft ft ft ft ft ft ft f # ft ####ttf ft ft ft ft ft ft It # ft #
Dose, Detailed model and Detailed Inventory Output Exclusion Area Boundary Doses:
Time (h) = 72.0036 Whole Body Thyroid TEDE Delta dose (rem) 3.9946E-03 1.0846E+00 3.7073E-02 Accumulated dose (rem) 3.9946E-03 1.0846E+00 3.7073E-02 Low Population Zone Doses:
Time (h) = 72.0036 Whole Body Thyroid TEDE Delta dose (rem) 6.9906E-04 1.8981E-01 6.4878E-03 Accumulated dose (rem) 6.9906E-04 1.8981E-01 6.4878E-03 Control Room Doses:
Time (h) = 72.0036 Whole Body Thyroid TEDE Delta dose (rem) 2.5519E-07 1.2176E-03 3.7387E-05 Accumulated dose (rem) 2.5519E-07 1.2176E-03 3.7387E-05 Control Room Compartment Nuclide Inventory:
Time (h) 72.0036 Ci kg Atoms Bq Kr-85 2.0817E-02 5.3058E-08 3.7591E+17 7.7022E+08 Kr-85m 3.3667E-06 4.0910E-16 2.8984E+09 1.2457E+05 Kr-88 1.5065E-08 1.2014E-18 8.2219E+06 5.5741E+02 I-131 4.3989E-03 3.5482E-11 1.6311E+14 1.6276E+08 1-133 6.7593E-04 5.9669E-13 2.7017E+12 2.5009E+07 I-135 3.6515E-06 1.0398E-15 4.6383E+09 1.3511E+05 Xe-133 1.0054E+00 5.3711E-09 2.4320E+16 3.7199E+10 Xe-135 2.2653E-03 8.8705E-13 3.9570E+12 8.3816E+07 Control Room Transport Group Inventory:
Overlying Time (h) = 72.0036 Atmosphere Sump Pool Noble gases (atoms) 4.0024E+17 0.OOOOE+O0 0.OOOOE+00 Elemental I (atoms) 9.4518E+13 0.0000E+00 O.OOOOE+00 Organic I (atoms) 7.1303E+13 0.0000E+00 O.OOOOE+00 Aerosols (kg) 0.0000E+00 0.OOOOE+00 O.OOOOE+00
I CALCULATION NOC- I 101 -900-E000483 I REV. No. 2 l PAGE NO. 40 l Deposition Recirculating Time (h) = 72.0036 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.0000E+00 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 72.0036 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 72.0036 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 72.0036 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 72.5000 Whole Body Thyroid TEDE Delta dose (rem) 4.3151E-01 1.1720E+02 4. 0058E+0o Accumulated dose (rem) 4.3551E-01 1.1829E+02 4.0429E+00 Low Population Zone Doses:
Time (h) = 72.5000 Whole Body Thyroid TEDE Delta dose (rem) 7.5515E-02 2.0510E+01 7.0101E-01 Accumulated dose (rem) 7.6214E-02 2.0700E+01 7.0750E-01 Control Room Doses:
Time (h) = 72.5000 Whole Body Thyroid TEDE Delta dose (rem) 5.2760E-03 2.5188E+01 7.7343E-01 Accumulated dose (rem) 5.2763E-03 2.5190E+01 7.7347E-01 Control Room Compartment Nuclide Inventory:
Time (h) = 72.5000 Ci kg Atoms Bq Kr-85 1.5368E+00 3.9169E-06 2.7751E+19 5.6860E+10 Kr-85m 2.3017E-04 2.7968E-14 1.9815E+11 8.5162E+06 Kr-88 9.8526E-07 7.8574E-17 5.3771E+08 3.6455E+04 I-131 3.2416E-01 2.6147E-09 1.2020E+16 1.1994E+10 I-133 4.9081E-02 4.3327E-11 1.9618E+14 1.8160E+09 I-135 2.5589E-04 7.2866E-14 3.2504E+11 9.4681E+06 Xe-133 7.4017E+01 3.9543E-07 1.7905E+18 2.7386E+12 Xe-135 1.6102E-01 6.3053E-11 2.8127E+14 5.9577E+09 Control Room Transport Group Inventory:
Overlying
CALCULATION NOC-1101-900-000-083 I REV. No. 2 1 PAGE NO.41 Time (h) = 72.5000 Atmosphere Sump Pool Noble gases (atoms) 2.9547E+19 O.0000E+O0 0.0000E+00 Elemental I (atoms) 6.9776E+15 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) 5.2638E+15 0.OOOOE+00 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Deposition Recirculating Time (h) = 72.5000 Surfaces Filter Noble gases (atoms) O.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.0000E+00 0.OOOOE+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.OOOOE+00 0.0000E+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 72.5000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 72.5000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 72.5000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 74.0000 Whole Body Thyroid TEDE Delta dose (rem) 4.9020E-02 1.3212E+01 4.5192E-01 Accumulated dose (rem) 4.8453E-01 1.3150E+02 4.4948E+00 Low Population Zone Doses:
Time (h) = 74.0000 Whole Body Thyroid TEDE Delta dose (rem) 8.5784E-03 2.3121E+00 7.9087E-02 Accumulated dose (rem) 8.4792E-02 2.3012E+01 7.8659E-01 Control Room Doses:
Time (h) = 74.0000 Whole Body Thyroid TEDE Delta dose (rem) 6.9692E-03 1.0593E+01 3.3000E-01 Accumulated dose (rem) 1.2245E-02 3.5782E+01 1.1035E+00 Control Room Compartment Nuclide Inventory:
Time (h) = 74.0000 Ci kg Atoms Bq Kr-85 7.4669E-02 1.9032E-07 1.3484E+18 2.7627E+09 Kr-85m 8.8673E-06 1. 0775E-15 7.6339E+09 3.2809E+05 Kr-88 3.3197E-08 2.6474E-18 1.8117E+07 1.2283E+03 1-131 7.7281E-05 6.2336E-13 2.8656E+12 2.8594E+06 1-133 1.1191E-05 9.8787E-15 4.4730E+10 4.1405E+05 1-135 5.2408E-08 1.4923E-17 6.6570E+07 1.9391E+03 Xe-133 3.5668E+00 1.9055E-08 8.6282E+16 1.3197E+11
CALCULATION NOC-I 10I-900-EOOO-083 I REV. No. 2 1 PAGE NO. 42 l Xe-135 6.9782E-03 2.7326E-12 1.2189E+13 2.5819E+08 Control Room Transport Group Inventory:
Overlying Time (h) = 74.0000 Atmosphere Sump Pool Noble gases (atoms) 1.4357E+18 0.0000E+00 0.OOOOE+00 Elemental I (atoms) 1.6725E+12 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) 1.2617E+12 0.0000E+00 0.OOOOE+00 Aerosols (kg) - 0.OOOOE+00 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 74.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 5.0618E+15 Organic I (atoms) 0.OOOOE+00 3.8186E+15 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 74.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 5.5700E+20 Organic I (atoms) 4.2019E+20 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 74.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 74.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 2.6246E+15 Organic I (atoms) 1.9800E+15 Aerosols (kg) 0.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 80.0000 Whole Body Thyroid TEDE Delta dose (rem) 1.6725E-05 0.OOOOE+00 1.6725E-05 Accumulated dose (rem) 4.8454E-01 1.3150E+02 4.4948E+00 Low Population Zone Doses:
Time (h) = 80.0000 Whole Body Thyroid TEDE Delta dose (rem) 1.2544E-06 0.OOOOE+00 1.2544E-06 Accumulated dose (rem) 8.4794E-02 2.3012E+01 7.8659E-01 Control Room Doses:
Time (h) = 80.0000 Whole Body Thyroid TEDE Delta dose (rem) 2.5846E-04 2.2952E-03 3.2845E-04 Accumulated dose (rem) 1.2504E-02 3.5784E+01 1.1038E+00 Control Room Compartment Nuclide Inventory:
Time (h) = 80.0000 Ci kg Atoms Bq Kr-85 5.6642E-08 1.4437E-13 1.0229E+12 2.0958E+03 Xe-133 2.6179E-06 1.3986E-14 6.3328E+10 9.6864E+04
CALCULATION NOC-I 101-900-EOOO-083 I REV. No. 2 l PAGE NO.43 Xe-135 3.3502E-09 1.3119E-18 5.8521E+06 1.2396E+02 Control Room Transport Group Inventory:
Overlying Time (h) = 80.0000 Atmosphere Sump Pool Noble gases (atoms) 1.0891E+12 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 1.8829E-06 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) 1.4205E-06 0.OOOOE+00 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Deposition Recirculating Time (h) = 80.0000 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 5.0629E+15 Organic I (atoms) 0.OOOOE+00 3.8194E+15 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 80.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 5.5700E+20 Organic I (atoms) 4.2019E+20 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 80.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 80.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 2.6252E+15 Organic I (atoms) 1.9804E+15 Aerosols (kg) 0.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 96.0000 Whole Body Thyroid TEDE Delta dose (rem) 1.2206E-11 0.OOOOE+00 1.2206E-11 Accumulated dose (rem) 4.8454E-01 1.3150E+02 4.4948E+00 Low Population Zone Doses:
Time (h) = 96.0000 Whole Body Thyroid TEDE Delta dose (rem) 5.9504E-13 0.OOOOE+00 5.9504E-13 Accumulated dose (rem) 8.4794E-02 2.3012E+01 7.8659E-01 Control Room Doses:
Time (h) = 96.0000 Whole Body Thyroid TEDE Delta dose (rem) 1.8860E-10 2.5192E-21 1.8860E-10 Accumulated dose (rem) 1.2504E-02 3.5784E+01 1.1038E+00 Control Room Compartment Nuclide Inventory:
Time (h) = 96.0000 Ci kg Atoms Bq Control Room Transport Group Inventory:
CALCULATION NOC-I 10I-900-EOOO-083 l REV. No. 2 I PAGE NO. 44 l Overlying Time (h) = 96.0000 Atmosphere Sump Pool Noble gases (atoms) 5.0579E-05 0.0000E+00 O.OOOOE+00 Elemental I (atoms) 2.5792E-54 O.OOOOE+00 0.0000E+00 Organic I (atoms) 1.9457E-54 0.OOOOE+00 0.0000E+00 Aerosols (kg) O.0000E+00 0.OOOOE+00 0.OOOOE+00 Deposition Recirculating Time (h) = 96.0000 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 5.0629E+15 Organic I (atoms) 0.OOOOE+00 3.8194E+15 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 5.5700E+20 Organic I (atoms) 4.2019E+20 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 2.6252E+15 Organic I (atoms) 1.9804E+15 Aerosols (kg) 0.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 168.0000 Whole Body Thyroid TEDE Delta dose (rem) 5.1678E-28 0.OOOOE+00 5.1678E-28 Accumulated dose (rem) 4.8454E-01 1.3150E+02 4.4948E+00 Low Population Zone Doses:
Time (h) = 168.0000 Whole Body Thyroid TEDE Delta dose (rem) 1.0336E-29 0.OOOOE+00 1.0336E-29 Accumulated dose (rem) 8.4794E-02 2.3012E+01 7.8659E-01 Control Room Doses:
Time (h) = 168.0000 Whole Body Thyroid TEDE Delta dose (rem) 1.1417E-26 1.2865E-68 1.1417E-26 Accumulated dose (rem) 1.2504E-02 3.5784E+01 1.1038E+00 Control Room Compartment Nuclide Inventory:
Time (h) = 168.0000 Ci kg Atoms Bq Control Room Transport Group Inventory:
Overlying Time (h) = 168.0000 Atmosphere Sump Pool
CALCULATION NOC- I10I-900-EOOO-083 lTREV.No. 2 T PAGE NO.45 Noble gases (atoms) 1.5550E-78 0.0000E+00 0.OOOOE+00 Elemental I (atoms) 1.0597-269 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) 7.9941-270 O.0000E+00 0.OOOOE+00 Aerosols (kg) O.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Deposition Recirculating Time (h) = 168.0000 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 5.0629E+15 Organic I (atoms) 0.0000E+00 3.8194E+15 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 168.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 5.5700E+20 Organic I (atoms) 4.2019E+20 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 168.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 168.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 2.6252E+15 Organic I (atoms) 1.9804E+15 Aerosols (kg) 0.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 720.0000 Whole Body Thyroid TEDE Delta dose (rem) 1.0663-101 0.OOOOE+00 1.0663-101 Accumulated dose (rem) 4.8454E-01 1.3150E+02 4.4948E+00 Low Population Zone Doses:
Time (h) = 720.0000 Whole Body Thyroid TEDE Delta dose (rem) 5.3315-104 0.OOOOE+00 5.3315-104 Accumulated dose (rem) 8.4794E-02 2.3012E+01 7. 8659E-01 Control Room Doses:
Time (h) = 720.0000 Whole Body Thyroid TEDE Delta dose (rem) 3.0855-100 5.3820-284 3.0855-100 Accumulated dose (rem) 1.2504E-02 3.5784E+01 1.1038E+00 Control Room Compartment Nuclide Inventory:
Time (h) = 720.0000 Ci kg Atoms Bq Control Room Transport Group Inventory:
Overlying Time (h) = 720.0000 Atmosphere Sump Pool Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00
I CALCULATION NOC-I 101-900-EOOO-083 l REV. No. 2 l PAGE NO. 46 l Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 720.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.OOOOE+00 Elemental I (atoms) 0.0000E+00 5.0629E+15 Organic I (atoms) 0.OOOOE+00 3.8194E+15 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 5.5700E+20 Organic I (atoms) 4.2019E+20 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 2.6252E+15 Organic I (atoms) 1.9804E+15 Aerosols (kg) 0.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 792.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Accumulated dose (rem) 4.8454E-01 1.3150E+02 4.4948E+00 Low Population Zone Doses:
Time (h) = 792.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.OOOOE+00 0.OOOOE+00 0.0000E+00 Accumulated dose (rem) 8.4794E-02 2.3012E+01 7.8659E-01 Control Room Doses:
Time (h) = 792.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Accumulated dose (rem) 1.2504E-02 3 .5784E+01 1.1038E+00 Control Room Compartment Nuclide Inventory:
Time (h) = 792.0000 Ci kg Atoms Bq Control Room Transport Group Inventory:
Overlying Time (h) = 792.0000 Atmosphere Sump Pool Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 O.OOOOE+00 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Deposition Recirculating
CALCULATION NOC-101-900-EOOO-083 - REV. No. 2 1 PAGE NO.47 Time (h) = 792.0000 Surfaces Filter Noble gases (atoms) o.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 5.0629E+15 Organic I (atoms) 0.OOOOE+00 3.8194E+15 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 792.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 5.5700E+20 Organic I (atoms) 4.2019E+20 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 792.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 792.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 2.6252E+15 Organic I (atoms) 1.9804E+15 Aerosols (kg) 0.OOOOE+00 334 I-131 Summary Containment Environment Control Room Time (hr) 1-131 (Curies) I-131 (Curies) I-131 (Curies) 72.001 6.5355E+01 8.3646E-02 1.0538E-04 72.004 4.2054E+02 3.4959E+00 4.3989E-03 72.400 6.7659E+01 3.5615E+02 3.3229E-01 72.500 4.2673E+01 3.8115E+02 3.2416E-01 72.800 1.0706E+01 4.1309E+02 4.9645E-02 73.100 2.6861E+00 4.2110E+02 8.4474E-03 73.400 6.7390E-01 4.2311E+02 1.6123E-03 73.700 1.6907E-01 4.2362E+02 3.4037E-04 74.000 4.2419E-02 4.2374E+02 7.7281E-05 74.300 4.2373E-02 4.2374E+02 9.7764E-06 74.600 4.2328E-02 4.2374E+02 1.2368E-06 74.900 4.2282E-02 4.2374E+02 1.5645E-07 75.200 4.2236E-02 4.2374E+02 1.9792E-08 75.500 4.2191E-02 4.2374E+02 2.5038E-09 75.800 4.2146E-02 4.2374E+02 3.1674E-10 76.100 4.2100E-02 4.2374E+02 4.0069E-11 76.400 4.2055E-02 4.2374E+02 5.0690E-12 76.700 4.2010E-02 4.2374E+02 6.4125E-13 77.000 4.1964E-02 4.2374E+02 8.1120E-14 77.300 4.1919E-02 4.2374E+02 1.0262E-14 77.600 4.1874E-02 4.2374E+02 1.2982E-15 77.900 4.1829E-02 4.2374E+02 1.6423E-16 78.200 4.1784E-02 4.2374E+02 2.0776E-17 78.500 4.1739E-02 4.2374E+02 2.6282E-18 78.800 4.1694E-02 4.2374E+02 3.3248E-19 79.100 4.1649E-02 4.2374E+02 4.2060E-20 79.400 4.1604E-02 4.2374E+02 5.3208E-21
CALCULATION NOC-I 101-900-EOOO-083 TREV. No. 2 _l PAGE NO.48 79.700 4.1559E-02 4.2374E+02 6.7310E-22 80.000 4.1514E-02 4.2374E+02 8.5151E-23 80.300 4.1470E-02 4.2374E+02 1.0772E-23
- 80. 600 4.1425E-02 4.2374E+02 1.3627E-24 80.900 4.1380E-02 4.2374E+02 1.7239E-25 81.200 4.1336E-02 4.2374E+02 2.1808E-26 81.500 4.1291E-02 4.2374E+02 2.7588E-27
- 81. 800 4.1247E-02 4.2374E+02 3.4900E-28 82.100 4.1202E-02 4.2374E+02 4.4150E-29 82.400 4.1158E-02 4.2374E+02 5.5852E-30
- 96. 000 3.9196E-02 4.2374E+02 1.1012E-70 168. 000 3.0263E-02 4.2374E+02 3.4934-286 720.000 4.1664E-03 4.2374E+02 O.OOOOE+00 792.000 3.2169E-03 4.2374E+02 O.OOOOE+00 Cumulative Dose Summary Exclusion Area Bounda Low Population Zone Contro]l Room Time Thyroid TEDE Thyroid TEDE Thyroid TEDE (hr) (rem) (rem) (rem) (rem) (rem) (rem) 72.001 2.5952E-02 8.8702E-04 4.5415E-03 1.5523E-04 5.7730E-06 1.7727E-07 72.004 1.0846E+00 3.7073E-02 1.8981E-01 6.4878E-03 1.2176E-03 3.7387E-05 72.400 1.1053E+02 3.7778E+00 1.9343E+01 6.6111E-01 1. 8717E+01 5.7473E-01 72.500 1.1829E+02 4.0429E+00 2.0700E+01 7.0750E-01 2.5190E+01 7.7347E-01 72.800 1.2819E+02 4.3816E+00 2.2434E+01 7.6679E-01 3.4069E+01 1.0475E+00 73.100 1.3068E+02 4.4667E+00 2.2869E+01 7.8167E-01 3.5474E+01 1.0923E+00 73.400 1.3130E+02 4.4881E+00 2.2978E+01 7.8541E-01 3.5722E+01 1.1009E+00 73.700 1.3146E+02 4.4934E+00 2.3005E+01 7.8635E-01 3.5771E+01 1.1029E+00 74.000 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5782E+01 1.1035E+00 74.300 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5784E+01 1.1037E+00 74.600 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5784E+01 1.1037E+00 74.900 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5784E+01 1.1038E+00 75.200 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5784E+Ol 1.1038E+00 75.500 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5784E+01 1.1038E+00 75.800 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5784E+01 1.1038E+00 76.100 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5784E+01 1.1038E+00 76.400 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5784E+01 1.1038E+00 76.700 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5784E+01 1.1038E+00 77.000 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5784E+01 1.1038E+00 77.300 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5784E+01 1.1038E+00 77.600 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5784E+01 1.1038E+00 77.900 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5784E+01 1.1038E+00 78.200 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3 .5784E+01 1.1038E+00 78.500 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5784E+01 1.1038E+00
- 78. 800 1.3150E+02 4:4948E+00 2.3012E+01 7.8659E-01 3.5784E+01 1.1038E+00 79.100 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5784E+01 1.1038E+00 79.400 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5784E+01 1.1038E+00 79.700 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5784E+01 1.1038E+00 80.000 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5784E+01 1.1038E+00 80.300 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5784E+01 1.1038E+00 80.600 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5784E+01 1.1038E+00 80.900 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5784E+01 1.1038E+00 81.200 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5784E+01 1.1038E+00 81.500 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5784E+01 1.1038E+00 81.800 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5784E+01 1.1038E+00 82.100 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5784E+01 1.1038E+00 82.400 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5784E+01 1.1038E+00 96.000 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5784E+01 1.1038E+00 168. 000 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5784E+01 1.1038E+00 720. 000 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5784E+01 1.1038E+00 792.000 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5784E+01 1.1038E+00 Worst Two-Hour Doses Note: All of the dose locations are shown below but the worst two-hour dose is only meaningful for the EAB
CALCULATION NOC-I 10I-900-EOOO-083 I REV. No. 2 l PAGE NO.49 dose location. Please disregard the two-hour worst doses for the other dose locations Exclusion Area Boundary Time Whole Body Thyroid TEDE (hr) (rem) (rem) (rem) 72.0 4.8443E-01 1.3147E+02 4.4939E+00 Low Population Zone Time Whole Body Thyroid TEDE (hr) (rem) (rem) (rem) 72.0 8.4776E-02 2.3008E+01 7. 8643E-01 Control Room Time Whole Body Thyroid TEDE (hr) (rem) (rem) (rem) 72.0 1.2245E-02 3.5782E+01 1.1035E+00
CALCULATION NOC-I10 I-900-EOOO-083 _ REV. No. 2 I PAGE NO.50 l Appendix D RADTRAD File OB.psf FHA Occurring In Reactor Building With Hatch Doors Opened CR Recirc Flow: 25,200 cfm CR Filtered Intake Flow: 8,000 cfm CR Unfiltered Inleakage: 1,000 cfm CR Exhaust Flow: 9,000 cfm Two Times Iodine & Noble Gas Release Fractions
CALCULATION NOC-110 1-900-EOOO-083 I REV. No. 2 I PAGE NO.51 RADTRAD Version 3.02 run on 7/07/2005 at 7:53:39 File information i#i##f####fi##### fi#### f#####fi########ii####f########fi### i########ifi############
i####fi###
Plant file name = C:\Program Files\U S Nuclear Regulatory Commission\Radtrad\OB.psf Inventory file name = c:\program files\u s nuclear regulatory commission\radtrad\defaults\fharb_def_a.nif Scenario file name = C:\Program Files\U S Nuclear Regulatory Commission\Radtrad\ OB.psf Release file name = c:\program files\u s nuclear regulatory commission\radtrad\defaults\fha update 6-9-05.rft Dose conversion file name = c:\program files\u s nuclear regulatory commission\radtrad\defaults\fgrll&12.inp ifififif ififififif if # if ififififif if if ifif###i
- ii if if# # if if if if if ifif if if if if if if if#ifif #if#if if if if if ifif##if if if if if # # if ## # if if if if if ififif if if if # if if #i#
Radtrad 3.02 1/5/2000 TMI-1 FHAIC With Hatch Doors Opened, AST Analysis, CR Charcoal Filter Efficiency =
75%., CR Recirc = 25,200 cfm, CR Intake = 8,000 cfm Nuclide Inventory File:
c:\program files\u s nuclear regulatory commission\radtrad\defaults\fharbdefa.nif Plant Power Level:
2.6190E+03 Compartments:
3 Compartment 1:
Containment 3
2.1600E+06 0
0 0
0 0
Compartment 2:
Environment 2
O.OOOOE+00 0
0 0
0 0
Compartment 3:
Control Room 1
2.5000E+05 0
0 1
0
ICALCULATION NOC-I 101-900-EOOO-083 - REV. No. 2 I PAGE NO. 52 0
Pathways:
4 Pathway 1:
Containment to Environment 1
2 2
Pathway 2:
Control Room Air Intake 2
3 2
Pathway 3:
Control Room Unfiltered Inleakage 2
3 2
Pathway 4:
Control Room Exhaust to Environment 3
2 2
End of Plant Model File Scenario Description Name:
Plant Model Filename:
Source Term:
1 1 1.0000E+00 c:\program files\u s nuclear regulatory commission\radtrad\defaults\fgrll&12.inp c:\program files\u s nuclear regulatory commission\radtrad\defaults\fha update 6 05.rft 7.2000E+01 0
O.0000E+00 5.7000E-01 4.3000E-01 1.OOOOE+00 Overlying Pool:
0 o.OOOOE+00 0
0 0
0 Compartments:
3 Compartment 1:
0 1
0 0
0O 0
0 0
0 Compartment 2:
0 1
0 0
0 0
0 0
0 Compartment 3:
1
CALCULATION NOC-1 101-900-EOOO-083 I REV. No. 2 1 PAGE NO.53 1
0 0
0 0
1 2.5200E+04 3
7.2000E+O1 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 7.2500E+O1 9.9000E+O1 7.5000E+01 7.5000E+01 7.9200E+02 9.9000E+O1 7.5000E+O1 7.5000E+01 0
0 Pathways:
4 Pathway 1:
0 0
0 0
0 1
3 7.2000E+O1 1.6580E+05 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 7.4000E+O1 O.OOOOE+O0 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 7.9200E+02 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 0
0 0
0 0
0 Pathway 2:
0 0
0 0
0 1
3 7.2000E+01 4.OOOOE+03 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 7.2500E+01 8.0000E+03 9.9000E+O1 7.5000E+01 7.5000E+01 7.9200E+02 8.0000E+03 9.9000E+O1 7.5000E+01 7.5000E+01 0
0 0
0 0
0 Pathway 3:
0 0
0 0
0 1
2 7.2000E+01 1.OOOOE+03 O.OOOOE+0O O.OOOOE+00 O.OOOOE+00 7.9200E+02 1.OOOOE+03 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 0
0 0
0 0
0 Pathway 4:
0 0
I CALCULATION NOC-I 101-900-EOOO-083 . REV. No. 2 _ l PAGE NO. 54 0
0 0
1 3
7.2000E+01 5.OOOOE+03 O.OOOOE+00 O.OOOOE+00 o .OOOOE+00 7.2500E+01 9.OOOOE+03 1. OOOOE+02 1.OOOOE+02 1.OOOOE+02 7.9200E+02 9.OOOOE+03 1.OOOOE+02 1.OOOOE+02 1.OOOOE+02 0
0 0
0 0
0 Dose Locations:
3 Location 1:
Exclusion Area Boundary 2
1 2
7.2000E+01 8.OOOOE-04 7.2000E+02 O.OOOOE+O0 1
2 7.2000E+01 3.5000E-04 7.2000E+02 0.OOOOE+00 0
Location 2:
Low Population Zone 2
1 6
7.2000E+01 1.4000E-04 7.4000E+01 6.OOOOE-05 8.OOOOE+01 3.9000E-05 9.6000E+01 1.6000E-05 1.6800E+02 4.0000E-06 7.9200E+02 O.OOOOE+00 1
4 7.2000E+01 3.5000E-04 8.OOOOE+01 1.8000E-04 9.6000E+01 2.3000E-04 7.9200E+02 O.OOOOE+00 0
Location 3:
Control Room 3
0 1
2 7.2000E+01 3.5000E-04 7.9200E+02 O.OOOOE+00 1
4 7.2000E+01 1.OOOOE+00 9.6000E+01 6.OOOOE-01 1.6800E+02 4.OOOOE-01 7.9200E+02 O.OOOOE+00 Effective Volume Location:
1 6
7.2000E+01 5.3400E-04 7.4000E+01 3. 1000E-04 8.OOOOE+01 1.3600E-04
- 9. 6000E+01 9.70OOE-05 1.6800E+02 6.0200E-05
CALCULATION NOC-i 101-900-E000-083 I REV. No. 2 l PAGE NO. 55 7.9200E+02 O.OOOOE+00 Simulation Parameters:
6 7.2000E+01 1.OOOOE-01 7.4000E+01 5.OOOOE-01 8.OOOOE+01 1.OOOOE+00 9.6000E+01 2.OOOOE+00 1.6800E+02 4.OOOOE+00 7.9200E+02 O.OOOOE+00 Output Filename:
C:\Program Files\U S Nuclear Regulatory Commission\Radtrad\0B.o2 1
1 1
0 0
End of Scenario File RADTRAD Version 3.02 run on 7/07/2005 at 7:53:39 Plant Description Number of Nuclides 60 Inventory Power = 1.0000E+00 MWth Plant Power Level = 2.6190E+03 MWth Number of compartments = 3 Compartment information Compartment number 1 (Source term fraction = l.OOOOE+00
)
Name: Containment Compartment volume 2.1600E+06 (Cubic feet)
Pathways into and out of compartment 1 Pathway to compartment number 2: Containment to Environment Compartment number 2 Name: Environment Pathways into and out of compartment 2 Pathway to compartment number 3: Control Room Air Intake Pathway to compartment number 3: Control Room Unfiltered Inleakage Pathway from compartment number 1: Containment to Environment Pathway from compartment number 3: Control Room Exhaust to Environment Compartment number 3 Name: Control Room Compartment volume = 2.5000E+05 (Cubic feet)
Removal devices within compartment:
Filter(s)
Pathways into and out of compartment 3 Pathway to compartment number 2: Control Room Exhaust to Environment Pathway from compartment number 2: Control Room Air Intake Pathway from compartment number 2: Control Room Unfiltered Inleakage Total number of pathways 4 RADTRAD Version 3.02 run on 7/07/2005 at 7:53:39
I CALCULATION NOC-101I-900-EOOO-083 7 No. 2
-REV. TPAGE NO.56 Scenario Description Time between shutdown and first release = 7.2000E+01 (Hours)
Radioactive Decay is enabled RELEASENAME = RG-1.183, Tables 3 Section 3.2 Release Fractions and Timings GAP EARLY IN-VESSEL 0.0036 hrs 0.0000 hrs NOBLES 1.0000E-01 0.OOOOE+00 IODINE 1.0000E-01 0.OOOOE+00 CESIUM 0.0000E+00 0.OOOOE+00 TELLURIUM 0.0000E+00 0.0000E+00 STRONTIUM 0.OOOOE+00 0.OOOOE+00 BARIUM 0.OOOOE+00 0.OOOOE+00 RUTHENIUM 0.OOOOE+00 0.OOOOE+00 CERIUM O.OOOOE+00 0.OOOOE+00 LANTHANUM 0.OOOOE+00 0.OOOOE+00 Iodine fractions Aerosol 0.OOOOE+00 Elemental 5.7000E-01 Organic 4.3000E-01 COMPARTMENT DATA Compartment number 1: Containment Compartment number 2: Environment Compartment number 3: Control Room Compartment Filter Data Time (hr) Flow Rate Filter Efficiencies (%)
(cfm) Aerosol Elemental Organic 7.2000E+01 2.5200E+04 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 7.2500E+01 2.5200E+04 9.9000E+01 7.5000E+01 7.5000E+01 7.9200E+02 2.5200E+04 9.9000E+01 7.5000E+01 7.5000E+01 PATHWAY DATA Pathway number 1: Containment to Environment Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)
(cfm) Aerosol Elemental Organic 7.2000E+01 1.6580E+05 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 7.4000E+01 0.OOOOE+00 0.OOOOE+00 0.0000E+00 0.OOOOE+00 7.9200E+02 0.OOOOE+00 0.OOOOE+00 0.0000E+00 0.0000E+00 Pathway number 2: Control Room Air Intake Pathway Filter: Removal Data Time (hr) Flow Rate Filteir Efficienciess()
(cfm) Aerosol Elemental Organic 7.2000E+01 4.OOOOE+03 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 7.2500E+01 8.OOOOE+03 9.9000E+01 7.5000E+01 7.5000E+01 7.9200E+02 8.0000E+03 9.9000E+01 7.5000E+01 7.5000E+01 Pathway number 3: Control Room Unfiltered Inleakage Pathway Filter: Removal Data
I CALCULATION NOC-I 101-900-EOOO-083 I REV. No. 2 I PAGE NO.57 Time (hr) Flow Rate Filter Efficiencies (%)
(cfm) Aerosol Elemental Organic 7.2000E+01 1.OOOOE+03 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 7.9200E+02 1.0000E+03 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 Pathway number 4: Control Room Exhaust to Environment Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)
(cfm) Aerosol Elemental Organic 7.2000E+01 5.OOOOE+03 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 7.2500E+01 9.OOOOE+03 1.0000E+02 1.0000E+02 1.OOOOE+02 7.9200E+02 9.OOOOE+03 1.0000E+02 1.OOOOE+02 1.0000E+02 LOCATION DATA Location Exclusion Area Boundary is in compartment 2 Location X/Q Data Time (hr) X/Q (s
- m^-3) 7.2000E+01 8.OOOOE-04 7.2000E+02 O.OOOOE+00 Location Breathing Rate Data Time (hr) Breathing Rate (mA3
- sec^-l) 7.2000E+01 3.5000E-04 7.2000E+02 0.000OE+00 Location Low Populiation Zone is in compartment 2 Location X/Q Data Time (hr) X/Q (s
- m'A-3) 7.2000E+01 1.4000E-04 7.4000E+01 6.OOOOE-05 8.OOOOE+01 3.9000E-05 9.6000E+01 1.6000E-05 1.6800E+02 4. OOOOE-06 7.9200E+02 O.OOOOE+00 Location Breathing Rate Data Time (hr) Breathing Rate (m^3
- secA-l) 7.2000E+01 3.5000E-04 8.OOOOE+01 1.8000E-04 9.6000E+01 2.3000E-04 7.9200E+02 O.OOOOE+00 Location Control Room is in compartment 3 Location X/Q Data Time (hr) X/I (s
- m^-3) 7.2000E+01 5.3400E-04 7.4000E+01 3.10OOE-04 8.OOOOE+01 1.3600E-04 9.6000E+01 9.70OOE-05 1.6800E+02 6.0200E-05 7.9200E+02 O.OOOOE+00 Location Breathing Rai:e Data Time (hr) Br(eathing Rate (mA3
- sec^-1) 7.2000E+01 3.5000E-04 7.9200E+02 O.OOOOE+00 Location Occupancy Facctor Data Time (hr) Occcupancy Factor 7.2000E+01 1.OOOOE+00 9.6000E+01 6.OOOOE-01 1.6800E+02 4.OOOOE-01 7.9200E+02 0.OOOOE+00
CALCULATION NOC-1 101-900-EOOO-083 I REV. No. 2 T PAGE NO. 58 USER SPECIFIED TIME STEP DATA - SUPPLEMENTAL TIME STEPS Time Time step 0.0000E+00 1.0000E-01 2.0000E+00 5.OOOOE-01 8.OOOOE+00 1.0000E+00 2.4000E+01 2.0000E+00 9.6000E+01 4.OOOOE+00 7.2000E+02 0.0000E+00 RADTRAD Version 3.02 run on 7/07/2005 at 7:53:39
- fi######i#######fi##f###############ii######i#########i#### f#############ii#######
- f## # ififif#if ifif##if I# # if #f I# # if #ifif ifif I # #
- if if if
- fi ####f if Dose, Detailed model and Detailed Inventory Output Exclusion Area Boundary Doses:
Time (h) = 72.0036 Whole Body Thyroid TEDE Delta dose (rem) 3.9946E-03 1.0846E+00 3.7073E-02 Accumulated dose (rem) 3.9946E-03 1.0846E+00 3.7073E-02 Low Population Zone Doses:
Time (h) = 72.0036 Whole Body Thyroid TEDE Delta dose (rem) 6.9906E-04 1.8981E-01 6.4878E-03 Accumulated dose (rem) 6.9906E-04 1.8981E-01 6.4878E-03 Control Room Doses:
Time (h) = 72.0036 Whole Body Thyroid TEDE Delta dose (rem) 2.5519E-07 1.2176E-03 3.7387E-05 Accumulated dose (rem) 2.5519E-07 1.2176E-03 3.7387E-05 Control Room Compartment Nuclide Inventory:
Time (h) = 72. 0036 Ci kg Atoms Bq Kr-85 2.0817E-02 5.3058E-08 3.7591E+17 7.7022E+08 Kr-85m 3.3667E-06 4.0910E-16 2.8984E+09 1.2457E+05 Kr-88 1.5065E-08 1.2014E-18 8.2219E+06 5.5741E+02 1-131 4.3989E-03 3.5482E-11 1.6311E+14 1.6276E+08 I-133 6.7593E-04 5.9669E-13 2.7017E+12 2.5009E+07 I-135 3.6515E-06 1.0398E-15 4.6383E+09 1.3511E+05 Xe-133 1.0054E+00 5.3711E-09 2.4320E+16 3.7199E+10 Xe-135 2.2653E-03 8.8705E-13 3.9570E+12 8.3816E+07 Control Room Transport Group Inventory:
Overlying Time (h) = 72.0036 Atmosphere Sump Pool Noble gases (atoms) 4.0024E+17 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 9.4518E+13 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) 7.1303E+13 0.OOOOE+00 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00
I CALCULATION NOC- I10I-900-EOOO-083 REV. No. 2 1 PAGE NO.59 Deposition Recirculating Time (h) = 72.0036 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) O.OOOOE+00 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 0.OOOOE+00 Aerosols (kg) O.OOOOE+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 72.0036 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 72.0036 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 72.0036 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) O.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 72.5000 Whole Body Thyroid TEDE Delta dose (rem) 4.3151E-01 1.1720E+02 4.0058E+00 Accumulated dose (rem) 4.3551E-01 1.1829E+02 4.0429E+00 Low Population Zone Doses:
Time (h) = 72.5000 Whole Body Thyroid TEDE Delta dose (rem) 7.5515E-02 2.0510E+01 7.0101E-01 Accumulated dose (rem) 7.6214E-02 2.0700E+01 7.0750E-01 Control Room Doses:
Time (h) = 72.5000 Whole Body Thyroid TEDE Delta dose (rem) 5.2760E-03 2.5188E+01 7.7343E-01 Accumulated dose (rem) 5.2763E-03 2.5190E+01 7.7347E-01 Control Room Compartment Nuclide Inventory:
Time (h) = 72.5000 Ci kg Atoms Bq Kr-85 1.5368E+00 3.9169E-06 2.7751E+19 5.6860E+10 Kr-85m 2.3017E-04 2.7968E-14 1.9815E+11 8.5162E+06 Kr-88 9.8526E-07 7. 8574E-17 5.3771E+08 3.6455E+04 I-131 3.2416E-01 2.6147E-09 1.2020E+16 1.1994E+10 I-133 4.9081E-02 4.3327E-11 1.9618E+14 1.8160E+09 1-135 2.5589E-04 7.2866E-14 3 .2504E+11 9.4681E+06 Xe-133 7.4017E+01 3.9543E-07 1.7905E+18 2.7386E+12 Xe-135 1.6102E-01 6.3053E-11 2.8127E+14 5.9577E+09 Control Room Transport Group Inventory:
Overlying
CALCULATION NOC-I 10I-900-EOOO-083 - REV. No. 2 - PAGE NO. 60 Time (h) = 72.5000 Atmosphere Sump Pool Noble gases (atoms) 2.9547E+19 0.0000E+00 0.0000E+00 Elemental I (atoms) 6.9776E+15 0.0000E+00 0.OOOOE+00 Organic I (atoms) 5.2638E+15 0.0000E+00 0.0000E+00 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Deposition Recirculating Time (h) = 72.5000 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 0.0000E+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 72.5000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 72.5000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 72.5000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 74.0000 Whole Body Thyroid TEDE Delta dose (rem) 4.9006E-02 1.3212E+01 4.5191E-01 Accumulated dose (rem) 4.8451E-01 1.3150E+02 4.4948E+00 Low Population Zone Doses:
Time (h) = 74.0000 Whole Body Thyroid TEDE Delta dose (rem) 8.5760E-03 2.3121E+00 7.9084E-02 Accumulated dose (rem) 8.4790E-02 2.3012E+01 7.8659E-01 Control Room Doses:
Time (h) = 74.0000 Whole Body Thyroid TEDE Delta dose (rem) 7.3488E-03 1.0815E+01 3.3715E-01 Accumulated dose (rem) 1.2625E-02 3.6004E+01 1.1106E+00 Control Room Compartment Nuclide Inventory:
Time (h) = 74.0000 Ci kg Atoms Bq Kr-85 9.3790E-02 2.3906E-07 1.6937E+18 3.4702E+09 Kr-85m 1.1138E-05 1.3534E-15 9.5889E+09 4.1211E+05 Kr-88 4.1698E-08 3.3254E-18 2.2757E+07 1.5428E+03 I-131 8.1594E-05 6.5815E-13 3.0255E+12 3.0190E+06 I-133 1.1815E-05 1.0430E-14 4.7226E+10 4.3716E+05 I-135 5.5333E-08 1.5756E-17 7.0286E+07 2.0473E+03 Xe-133 4.4803E+00 2.3935E-08 1.0838E+17 1.6577E+11
II REV. No. 2 NO.61 I CACLTO NOC-II CALCULATION _Q- I 101-900-EOOO-083
- O-0-OO.8 E.N.2I I PAGE AEN.6 Xe-135 8.7652E-03 3.4323E-12 1.5311E+13 3.2431E+08 Control Room Transport Group Inventory:
Overlying Time (h) = 74.0000 Atmosphere Sumnp Pool Noble gases (atoms) 1.8033E+18 0.OOOOE+00 O.OOOOE+00 Elemental I (atoms) 1.7658E+12 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) 1.3321E+12 0.OOOOE+00 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Deposition Recirculating Time (h) = 74.0000 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 5.1771E+15 Organic I (atoms) 0.OOOOE+00 3.9056E+15 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 74.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 5.0636E+20 Organic I (atoms) 3.8199E+20 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 74.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 74.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 2.4653E+15 Organic I (atoms) 1.8598E+15 Aerosols (kg) 0.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 80.0000 Whole Body Thyroid TEDE Delta dose (rem) 2.1001E-05 0.OOOOE+00 2.1001E-OS Accumulated dose (rem) 4.8453E-01 1.3150E+02 4.4948E+00 Low Population Zone Doses:
Time (h) = 80.0000 Whole Body Thyroid TEDE Delta dose (rem) 1.5751E-06 0.OOOOE+00 1.5751E-06 Accumulated dose (rem) 8.4791E-02 2.3012E+01 7.8659E-01 Control Room Doses:
Time (h) = 80.0000 Whole Body Thyroid TEDE Delta dose (rem) 3.5312E-04 2.4876E-03 4.2897E-04 Accumulated dose (rem) 1.2978E-02 3.6007E+01 1.ll11E+00 Control Room Compartment Nuclide Inventory:
Time (h) = 80.0000 Ci kg Atoms Bq Kr-85 2.2444E-07 5.7205E-13 4.0529E+12 8.3041E+03 Xe-133 1.0373E-05 5.5417E-14 2.5093E+11 3.8381E+05
CALCULATION NOC-1 101-900-EOOO-083 l REV. No. 2 I PAGE NO.62 l Xe-135 1.3274E-08 5.1981E-18 2.3188E+07 4.9116E+02 Control Room Transport Group Inventory:
Overlying Time (h) = 80.0000 Atmosphere Sump Pool Noble gases (atoms) 4.3154E+12 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 6.2911E-06 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) 4.7459E-06 0.OOOOE+00 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Deposition Recirculating Time (h) = 80.0000 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 5.1783E+15 Organic I (atoms) 0.0000E+00 3.9065E+15 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 80.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 5.0636E+20 Organic I (atoms) 3.8199E+20 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 80.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 80.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 2.4659E+15 Organic I (atoms) 1.8602E+15 Aerosols (kg) 0.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 96.0000 Whole Body Thyroid TEDE Delta dose (rem) 4.8350E-11 0.OOOOE+00 4.8350E-11 Accumulated dose (rem) 4.8453E-01 1.3150E+02 4.4948E+00 Low Population Zone Doses:
Time (h) = 96.0000 Whole Body Thyroid TEDE Delta dose (rem) 2.3571E-12 0.OOOOE+00 2.3571E-12 Accumulated dose (rem) 8.4791E-02 2.3012E+01 7.8659E-01 Control Room Doses:
Time (h) = 96.0000 Whole Body Thyroid TEDE Delta dose (rem) 8.1291E-10 8.6404E-21 8.1291E-10 Accumulated dose (rem) 1.2978E-02 3.6007E+01 l.llllE+00 Control Room Compartment Nuclide Inventory:
Time (h) = 96.0000 Ci kg Atoms Bq Control Room Transport Group Inventory:
CALCULATION NOC-1 101-900-EOOO-083 l REV. No. 2 l PAGE NO.63 l Overlying Time (h) = 96.0000 Atmosphere Sump Pool Noble gases (atoms) 4.3099E-03 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 1.8607E-52 O.0000E+00 0.000E+00 Organic I (atoms) 1.4037E-52 0.OOOOE+00 0.0000E+00 Aerosols (kg) 0.OOOOE+00 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 96.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 5.1783E+15 Organic I (atoms) 0.OOOOE+00 3.9065E+15 Aerosols (kg) 0.0000E+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 5.0636E+20 Organic I (atoms) 3.8199E+20 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 2.4659E+15 Organic I (atoms) 1.8602E+15 Aerosols (kg) 0.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 168.0000 Whole Body Thyroid TEDE Delta dose (rem) 4.4032E-26 O.0000E+00 4.4032E-26 Accumulated dose (rem) 4.8453E-01 1.3150E+02 4.4948E+00 Low Population Zone Doses:
Time (h) = 168.0000 Whole Body Thyroid TEDE Delta dose (rem) 8.8064E-28 0.OOOOE+00 8.8064E-28 Accumulated dose (rem) 8.4791E-02 2.3012E+01 7.8659E-01 Control Room Doses:
Time (h) = 168.0000 Whole Body Thyroid TEDE Delta dose (rem) 9.8113E-25 9.2810E-67 9.8113E-25 Accumulated dose (rem) 1.2978E-02 3.6007E+01 1.1111E+00 Control Room Compartment Nuclide Inventory:
Time (h) = 168.0000 Ci kg Atoms Bq Control Room Transport Group Inventory:
Overlying Time (h) = 168.0000 Atmosphere Sump Pool
CALCULATION NOC-1 101-900-EOOO-083 - REV. No. 2 l PAGE NO.64 l Noble gases (atoms) 1.3206E-70 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 7.7256-262 0.0000E+00 0.OOOOE+00 Organic I (atoms) 5.8281-262 0.OOOOE+00 o.OOOOE+00 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 0.0000E+00 Deposition Recirculating Time (h) = 168.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.OOOOE+00 Elemental I (atoms) 0.0000E+00 5.1783E+15 Organic I (atoms) 0.OOOOE+00 3.9065E+15 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 168.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 5.0636E+20 Organic I (atoms) 3.8199E+20 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 168.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 168.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 2.4659E+15 Organic I (atoms) 1.8602E+15 Aerosols (kg) 0.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 720.0000 Whole Body Thyroid TEDE Delta dose (rem) 9.0557E-94 0.OOOOE+00 9.0557E-94 Accumulated dose (rem) 4.8453E-01 1.3150E+02 4.4948E+00 Low Population Zone Doses:
Time (h) = 720.0000 Whole Body Thyroid TEDE Delta dose (rem) 4.5279E-96 0.OOOOE+00 4.5279E-96 Accumulated dose (rem) 8.4791E-02 2.3012E+01 7.8659E-01 Control Room Doses:
Time (h) = 720.0000 Whole Body Thyroid TEDE Delta dose (rem) 2.6210E-92 3.9237-276 2.6210E-92 Accumulated dose (rem) 1.2978E-02 3.6007E+01 1.1111E+00 Control Room Compartment Nuclide Inventory:
Time (h) = 720.0000 Ci kg Atoms Bq Control Room Transport Group Inventory:
Overlying Time (h) = 720.0000 Atmosphere Sump Pool Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00
CALCULATION NOC-I 10I-900-EOOO-083 l REV. No. 2 l PAGE NO. 65 l Aerosols (kg) 0.0000E+00 0.OOOOE+00 0.OOOOE+00 Deposition Recirculating Time (h) = 720.0000 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 5.1783E+15 Organic I (atoms) 0.OOOOE+00 3.9065E+15 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 5.0636E+20 Organic I (atoms) 3.8199E+20 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 2.4659E+15 Organic I (atoms) 1.8602E+15 Aerosols (kg) 0.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 792.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.OOOOE+00 0.0000E+00 0.OOOOE+00 Accumulated dose (rem) 4.8453E-01 1.3150E+02 4.4948E+00 Low Population Zone Doses:
Time (h) = 792.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Accumulated dose (rem) 8.4791E-02 2.3012E+01 7.8659E-01 Control Room Doses:
Time (h) = 792.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Accumulated dose (rem) 1.2978E-02 3.6007E+01 l.1111E+00 Control Room Compartment Nuclide Inventory:
Time (h) = 792.0000 Ci kg Atoms Bq Control Room Transport Group Inventory:
Overlying Time (h) = 792.0000 Atmosphere Sump Pool Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Deposition Recirculating
II REV. No. 22 I PAGE NO. 66 II CALCULATION CALCULATION NOC- 10l-900-EOOO-083 NOC-lI 10 I -900-EOOO-083 REV.No. IPAGE NO.66 I Time (h) = 792.0000 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 O.0000E+00 Elemental I (atoms) 0.OOOOE+00 5.1783E+15 Organic I (atoms) 0.OOOOE+00 3.9065E+15 Aerosols (kg) 0.0000E+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 792.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 5.0636E+20 Organic I (atoms) 3.8199E+20 Aerosols (kg) O.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 792.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 792.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 2.4659E+15 Organic I (atoms) 1.8602E+15 Aerosols (kg) 0.OOOOE+00 334 I-131 Summary Containment Environment Control Room Time (hr) I-131 (Curies) I-131 (Curies) I-131. (Curies) 72.001 6.5355E+01 8.3646E-02 1.0538E-04 72.004 4.2054E+02 3.4959E+00 4.3989E-03 72.400 6.7659E+01 3.5615E+02 3.3229E-01 72.500 4.2673E+01 3.8115E+02 3.2416E-01 72.800 1.0706E+01 4.1309E+02 5.1747E-02 73.100 2.6861E+00 4.2110E+02 9.0188E-03 73.400 6.7390E-01 4.2311E+02 1.7315E-03 73.700 1.6907E-01 4.2362E+02 3.6324E-04 74.000 4.2419E-02 4.2374E+02 8.1594E-05 74.300 4.2373E-02 4.2374E+02 1.0934E-05 74.600 4.2328E-02 4.2374E+02 1.4652E-06 74.900 4.2282E-02 4.2374E+02 1.9635E-07 75.200 4.2236E-02 4.2374E+02 2.6311E-08 75.500 4.2191E-02 4.2374E+02 3.5258E-09 75.800 4.2146E-02 4.2374E+02 4.7248E-10 76.100 4.2100E-02 4.2374E+02 6.3315E-11 76.400 4.2055E-02 4.2374E+02 8.4845E-12 76.700 4.2010E-02 4.2374E+02 1.1370E-12 77.000 4.1964E-02 4.2374E+02 1.5236E-13 77.300 4.1919E-02 4.2374E+02 2.0417E-14
- 77. 600 4.1874E-02 4.2374E+02 2.7360E-15 77.900 4.1829E-02 4.2374E+02 3.6663E-16 78.200 4.1784E-02 4.2374E+02 4.9131E-17
- 78. 500 4.1739E-02 4.2374E+02 6.5838E-18 78.800 4.1694E-02 4.2374E+02 8.8226E-19 79.100 4.1649E-02 4.2374E+02 1.1823E-19 79.400 4.1604E-02 4.2374E+02 1.5843E-20
I CALCULATION NOC-1101-900-13000-083 I~~~~ ~ CACLTO I REV. .N. 2 No.
E NO... 21O-90-OO-83 ITPAGE IP NO. 67 ENO6 I 79.700 4.1559E-02 4.2374E+02 2.1231E-21 80.000 4.1514E-02 4.2374E+02 2.8450E-22
- 80. 300 4.1470E-02 4.2374E+02 3.8124E-23
- 80. 600 4.1425E-02 4.2374E+02 5.1089E-24 80.900 4.1380E-02 4.2374E+02 6.8461E-25 81.2 00 4.1336E-02 4.2374E+02 9.1742E-26 81.500 4.1291E-02 4.2374E+02 1.2294E-26
- 81. 800 4.1247E-02 4.2374E+02 1.6474E-27 82.100 4.1202E-02 4.2374E+02 2.2076E-28 82.400 4.1158E-02 4.2374E+02 2.9584E-29
- 96. 000 3.9196E-02 4.2374E+02 7.9444E-69 168.000 3.0263E-02 4.2374E+02 2.5468-278 720.000 4.1664E-03 4.2374E+02 O.OOOOE+00 792.000 3.2169E-03 4.2374E+02 O.OOOOE+00 Cumulative Dose Summary Exclusion Area Bounda Low Population Zone Control Room Time Thyroid TEDE Thyroid TEDE Thyroid TEDE (hr) (rem) (rem) (rem) (rem) (rem) (rem) 72.001 2.5952E-02 8.8702E-04 4.5415E-03 1.5523E-04 5.7730E-06 1.7727E-07 72.004 1.0846E+00 3.7073E-02 1.8981E-01 6.4878E-03 1.2176E-03 3.7387E-05 72.400 1.1053E+02 3.7778E+00 1.9343E+01 6.6111E-01 1.8717E+01 5.7473E-01 72.500 1.1829E+02 4.0429E+00 2.0700E+01 7.0750E-01 2.5190E+01 7.7347E-01 72.800 1.2819E+02 4.3816E+00 2.2434E+01 7.6679E-01 3.4197E+01 1.0515E+00 73.100 1.3068E+02 4.4667E+00 2.2869E+01 7.8167E-01 3.5674E+01 1.0985E+00 73.400 1.3130E+02 4.4880E+00 2.2978E+01 7.8541E-01 3.5940E+01 1.1077E+00 73.700 1.3146E+02 4.4934E+00 2.3005E+01 7.8635E-01 3.5993E+01 1.1100E+00 74.000 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.6004E+01 1.1106E+00 74.300 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.6006E+01 1.1109E+00 74.600 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.6007E+01 1.111OE+00 74.900 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.6007E+01 1.111OE+00 75.200 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.6007E+01 1.111OE+00 75.500 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.6007E+01 1.111OE+00 75.800 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.6007E+01 1.111OE+00 76.100 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.6007E+01 1.111OE+00 76.400 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.6007E+01 1.1111E+00 76.700 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.6007E+01 1.1111E+00 77.000 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.6007E+0 1.1111E+00 77.300 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.6007E+0 1.1111E+00 77.600 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.6007E+01 1.1111E+00 77.900 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.6007E+01 1.111lE+00 78.200 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.6007E+01 1.111lE+00 78.500 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.6007E+01 1.1111E+00 78.800 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.6007E+01 1.1111E+00 79.100 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.6007E+01 1.1111E+00 79.400 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.6007E+01 1.111lE+00 79.700 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.6007E+01 1.l111E+00 80.000 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.6007E+01 1.1111E+00 80.300 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.6007E+0 1.1111E+00
- 80. 600 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.6007E+01 1.1111E+00
- 80. 900 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.6007E+01 1.1111E+00 81.200 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.6007E+01 1.1111E+00 81.500 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.6007E+01 1.1111E+00
- 81. 800 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.6007E+01 1.1111E+00 82.100 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.6007E+01 1.1111E+00 82.400 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.6007E+01 1.1111E+00
- 96. 000 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.6007E+01 1.1111E+00 168. 000 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.6007E+01 1.11l1E+00 720.000 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.6007E+01 1.1111E+00 792.000 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.6007E+01 1.1111E+00 Worst Two-Hour Doses Note: All of the dose locations are shown below but the worst two-hour dose is only meaningful for the EAB
CALCULATION NOC-1101-900-EOOO-083 I REV. No. 2 1 PAGENO.68 dose location. Please disregard the two-hour worst doses for the other dose locations Exclusion Area Boundary Time Whole Body Thyroid TEDE (hr) (rem) (rem) (rem) 72.0 4.8442E-01 1.3147E+02 4.4939E+00 Low Population Zone Time Whole Body Thyroid TEDE (hr) (rem) (rem) (rem) 72.0 8.4773E-02 2.3008E+01 7.8643E-01 Control Room Time Whole Body Thyroid TEDE (hr) (rem) (rem) (rem) 72.0 1.2625E-02 3.6004E+01 1.1106E+00
CALCULATION NOC-I 101-900-EOOO-083 I REV. No. 2 @PAGE NO. 69 l Appendix E RADTRAD File OC.psf FHA Occurring In Reactor Building With Hatch Doors Opened CR Recirc Flow: 25,200 cfm CR Filtered Intake Flow: 7,200 cfm CR Unfiltered Inleakage: 1,000 cfm CR Exhaust Flow: 8,200 cfm Two Times Iodine & Noble Gas Release Fractions
CALCULATION NOC-1101-900-E000-083 REV. No. 2 1 PAGE NO.70 RADTRAD Version 3.02 run on 7/07/2005 at 7:53:39 File information Plant file name = C:\Program Files\U S Nuclear Regulatory Commission\Radtrad\OC.psf Inventory file name = c:\program files\u s nuclear regulatory commission\radtrad\defaults\fharbdef_a.nif Scenario file name = C:\Program Files\U S Nuclear Regulatory Commission\Radtrad\OC.psf Release file name = c:\program files\u s nuclear regulatory commission\radtrad\defaults\fha update 6-9-05.rft Dose conversion file name = c:\program files\u s nuclear regulatory commission\radtrad\defaults\fgrll&12.inp i#i### #### ####t# # # #t i#####
- t # #t #t # ##
i # #t # it it it it it it
- t #ti # #it# # #i#i it it it it it it it it it
- t ### it #i # ##t itititit it Radtrad 3.02 1/5/2000 TMI-1 FHAIC With Hatch Doors Opened, AST Analysis, CR Charcoal Filter Efficiency =
75%., CR Recirc = 25,200 cfm, CR Intake = 7,200 cfm Nuclide Inventory File:
c:\program files\u s nuclear regulatory commission\radtrad\defaults\fharb_def_a.nif Plant Power Level:
2.6190E+03 Compartments:
3 Compartment 1:
Containment 3
2.1600E+06 0
0 0
0 0
Compartment 2:
Environment 2
O.OOOOE+00 0
0 0
0 0
Compartment 3:
Control Room 1
2.5000E+05 0
0 1
0
CALCULATION NOC-1101-900-EOOO-083 I REV. No. 2 1 PAGE NO.71 0
Pathways:
4 Pathway 1:
Containment t:o Environment 1
2 2
Pathway 2:
Control Room Air Intake 2
3 2
Pathway 3:
Control Room Unfiltered Inleakage 2
3 2
Pathway 4:
Control Room Exhaust to Environment 3
2 2
End of Plant Model File Scenario Description Name:
Plant Model Filename:
Source Term:
1 1 1.0000E+00 c:\program files\u s nuclear regulatory commission\radtrad\defaults\fgrll&12.inp c:\program files\u s nuclear regulatory commission\radtrad\defaults\fha update 6 05.rft 7.2000E+01 0
0.OOOOE+00 5.7000E-01 4.3000E-01 1.000OE+00 Overlying Pool:
0 0.OOOOE+00 0
0 0
0 Compartments:
3 Compartment 1:
0 1
0 0
0 0
0 0
0 Compartment 2:
0 1
0 0
0 0
0 0
0 Compartment 3:
1
I CALCULATION NOC-I 10 I1-900-EOOO-083 I REV. No. 2 1 PAGE NO. 72 1
0 0
0 0
1 2.5200E+04 3
7.2000E+01 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 7.2500E+01 9.9000E+01 7.5000E+01 7.5000E+01 7.9200E+02 9.9000E+01 7.5000E+01 7.5000E+01 0
0 Pathways:
4 Pathway 1:
0 0
0 0
0 1
3 7.2000E+01 1.6580E+05 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 7.4000E+01 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 7.9200E+02 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 0
0 0
0 0
0 Pathway 2:
0 0
0 0
0 1
3 7.2000E+01 4.0000E+03 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 7.2500E+01 7.2000E+03 9.9000E+01 7.5000E+01 7.5000E+01 7.9200E+02 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 0
0 0
0 0
0 Pathway 3:
0 0
0 0
0 1
2 7.2000E+01 1.OOOOE+03 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 7.9200E+02 1.OOOOE+03 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 0
0 0
0 0
0 Pathway 4:
0 0
ICALCULATION NOC-I 1O1-900-EOOO-083 I REV. No. 2 l PAGE NO.73 1 0
0 0
1 3
7.2000E+01 5.OOOOE+03 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 7.2500E+01 8.2000E+03 1.OOOOE+02 1.OOOOE+02 1.OOOOE+02 7.9200E+02 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 0
0 0
0 0
0 Dose Locations:
3 Location 1:
Exclusion Area Boundary 2
1 2
7.2000E+01 8.OOOOE-04 7.2000E+02 O.OOOOE+00 1
2 7.2000E+01 3.5000E-04 7.2000E+02 O.OOOOE+00 0
Location 2:
Low Population Zone 2
1 6
7.2000E+01 1.4000E-04 7.4000E+01 6.OOOOE-05 8.OOOOE+01 3.9000E-05 9.6000E+01 1.6000E-05 1.6800E+02 4.OOOOE-06 7.9200E+02 O.OOOOE+00 1
4 7.2000E+01 3.5000E-04
- 8. OOOOE+01 1.8000E-04 9.6000E+01 2.3000E-04 7.9200E+02 O.OOOOE+00 0
Location 3:
Control Room 3
0 1
2 7.2000E+01 3.5000E-04 7.9200E+02 O.OOOOE+00 1
4 7.2000E+01 l.OOOOE+00 9.6000E+01 6.OOOOE-01 1.6800E+02 4.OOOOE-01 7.9200E+02 O.OOOOE+00 Effective Volume Location:
1 6
7.2000E+01 5.3400E-04 7.4000E+01 3.1000E-04 8.OOOOE+01 1.3600E-04 9.6000E+01 9.70OOE-05 1.6800E+02 6.0200E-05
CALCULATION NOC-1101-900-EOOO-083 I REV. No. 2 l PAGE NO.74 l 7.9200E+02 O.OOOOE+OO Simulation Parameters:
6 7.2000E+01 1.OOOOE-01 7.4000E+01 5.OOOOE-01 8.OOOOE+01 1.OOOOE+00 9.6000E+01 2.OOOOE+00 1.6800E+02 4.OOOOE+00 7.9200E+02 O.OOOOE+00 Output Filename:
C:\Program Files\U S Nuclear Regulatory Commission\Radtrad\OC.o2 1
1 0
0 End of Scenario File RADTRAD Version 3.02 run on 7/07/2005 at 7:53:39 Plant Description Number of Nuclides = 60 Inventory Power = 1.OOOOE+00 MWth Plant Power Level = 2.6190E+03 MWth Number of compartments = 3 Compartment information Compartment number 1 (Source term fraction = l.OOOOE+00
)
Name: Containment Compartment volume = 2.1600E+06 (Cubic feet)
Pathways into and out of compartment 1 Pathway to compartment number 2: Containment to Environment Compartment number 2 Name: Environment Pathways into and out of compartment 2 Pathway to compartment number 3: Control Room Air Intake Pathway to compartment number 3: Control Room Unfiltered Inleakage Pathway from compartment number 1: Containment to Environment Pathway from compartment number 3: Control Room Exhaust to Environment Compartment number 3 Name: Control Room Compartment volume = 2.5000E+05 (Cubic feet)
Removal devices within compartment:
Filter(s)
Pathways into and out of compartment 3 Pathway to compartment number 2: Control Room Exhaust to Environment Pathway from compartment number 2: Control Room Air Intake Pathway from compartment number 2: Control Room Unfiltered Inleakage Total number of pathways = 4 RADTRAD Version 3.02 run on 7/07/2005 at 7:53:39
CALCULATION NOC-I 101-900-EOOO-083 I REV. No. 2 1 PAGE NO.75_
Scenario Description Time between shutdown and first release = 7.2000E+01 (Hours)
Radioactive Decay is enabled RELEASE_NAME = RG-1.183, Tables 3 Section 3.2 Release Fractions and Timings GAP EARLY IN-VESSEL 0.0036 hrs 0.0000 hrs NOBLES 1.0000E-01 0.0000E+00 IODINE 1.OOOOE-01 0.OOOOE+00 CESIUM 0.0000E+00 0.0000E+00 TELLURIUM 0.0000E+00 0.0000E+00 STRONTIUM 0.OOOOE+00 0.OOOOE+00 BARIUM 0.OOOOE+00 0.OOOOE+00 RUTHENIUM 0.OOOOE+00 0.OOOOE+00 CERIUM 0.OOOOE+00 0.OOOOE+00 LANTHANUM 0.OOOOE+00 0.OOOOE+00 Iodine fractions Aerosol 0.OOOOE+00 Elemental 5.7000E-01 Organic 4.3000E-01 COMPARTMENT DATA Compartment number 1: Containment Compartment number 2: Environment Compartment number 3: Control Room Compartment Filter Data Time (hr) Flow Rate Filter Efficiencies (%)
(cfm) Aerosol Elemental Organic 7.2000E+01 2.5200E+04 0.OOOOE+00 0.0000E+00 0.0000E+00 7.2500E+01 2.5200E+04 9.9000E+01 7.5000E+01 7.5000E+01 7.9200E+02 2.5200E+04 9.9000E+01 7.5000E+01 7.5000E+01 PATHWAY DATA Pathway number 1: Containment to Environment Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)
(cfm) Aerosol Elemental Organic 7.2000E+01 1.6580E+05 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 7.4000E+01 O.OOOOE+00 0.0000E+00 O.0000E+00 0.OOOOE+00 7.9200E+02 0.0000E+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Pathway number 2: Control Room Air Intake Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)
(cfm) Aerosol Elemental Organic 7.2000E+01 4.0000E+03 0.0000E+00 0.OOOOE+00 0.OOOOE+00 7.2500E+01 7.2000E+03 9.9000E+01 7.5000E+01 7.5000E+01 7.9200E+02 0.OOOOE+00 0.OOOOE+00 0.0000E+00 O.OOOOE+00 Pathway number 3: Control Room Unfiltered Inleakage Pathway Filter: Removal Data
I CALCULATION NOC-I 10I-900-EOOO-083 I REV. No. 2 - PAGE NO. 76 Time (hr) Flow Rate Filter Efficiencies (%)
(cfm) Aerosol Elemental Organic 7.2000E+01 1.OOOOE+03 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 7.9200E+02 1.OOOOE+03 0.OOOOE+00 O.OOOOE+00 0.OOOOE+00 Pathway number 4: Control Room Exhaust to Environment Pathway Filter: Removal Data Time (hr) Flow Rate Filtezr Efficiencies; %)
(cfm) Aerosol Elemental Organic 7.2000E+01 5.0000E+03 0.0000E+00 O.OOOOE+00 0.0000E+00 7.2500E+01 8.2000E+03 1.0000E+02 1.OOOOE+02 1.0000E+02 7.9200E+02 0.OOOOE+00 0.0000E+00 0.OOOOE+00 0.OOOOE+00 LOCATION DATA Location Exclusion Area Boundary is in compartment 2 Location X/Q Data Time (hr) X/Q (s
- mA-3) 7.2000E+01 8. OOOOE-04 7.2000E+02 0.OOOOE+00 Location Breathing Rate Data Time (hr) Breathing Rate (m^3
- sec^-l) 7.2000E+01 3.5000E-04 7.2000E+02 0.OOOOE+00 Location Low Populaation Zone is in compartment 2 Location X/Q Data Time (hr) X/1' (s
- m^-3) 7.2000E+01 1.4000E-04 7.4000E+01 6.OOO0E-05 8.0000E+01 3.9000E-05 9.6000E+01 1.6000E-05 1.6800E+02 4.OOOOE-06 7.9200E+02 0.0000E+00 Location Breathing Ralte Data Time (hr) Br eathi.ng Rate (m^3
- sec^-l) 7.2000E+01 3.5000E-04 8.0000E+01 1.8000E-04 9.6000E+01 2.3000E-04 7.9200E+02 O.OOOOE+00 Location Control Room is in compartment 3 Location X/Q Data Time (hr) X/(2 (s
- m^-3) 7.2000E+01 5.3400E-04 7.4000E+01 3.1000E-04 8.OOOOE+01 1.360OE-04 9.6000E+01 9.7000E-05 1.6800E+02 6.0200E-05 7.9200E+02 0.OOOOE+00 Location Breathing Rat:e Data Time (hr) BrEeathing Rate (m^3
- sec^-1) 7.2000E+01 3.5000E-04 7.9200E+02 0.OOOOE+00 Location Occupancy Facctor Data Time (hr) Occcupancy Factor 7.2000E+01 1.0000E+00 9.6000E+01 6.OOOOE-01 1.6800E+02 4.OOOOE-01 7.9200E+02 0.OOOOE+00
CALCULATION NOC-I 101-900-EOOO-083 -TREV. No. 2 1 PAGE NO.77 USER SPECIFIED TIME STEP DATA - SUPPLEMENTAL TIME STEPS Time Time step O.OOOOE+00 1.0000E-01 2.0000E+00 5.OOOOE-01 8.OOOOE+00 1.OOOOE+00 2.4000E+01 2.OOOOE+00 9.6000E+01 4.OOOOE+00 7.2000E+02 0.OOOOE+00 RADTRAD Version 3.02 run on 7/07/2005 at 7:53:39
- fi # if i#####i #####if # # if#i###
- f #i if# f if# # # # #f
- #i # #f #f # # # # #
- f # # # #f #####i #f # #
- f i# # # #f f
- f # # #
if i# # #f # # #f # if
- fi f#### #f #f ####fi #
Dose, Detailed model and Detailed Inventory Output Exclusion Area Boundary Doses:
Time (h) = 72.0036 Whole Body Thyroid TEDE Delta dose (rem) 3.9946E-03 1.0846E+00 3.7073E-02 Accumulated dose (rem) 3.9946E-03 1.0846E+00 3.7073E-02 Low Population Zone Doses:
Time (h) = 72.0036 Whole Body Thyroid TEDE Delta dose (rem) 6.9906E-04 1.8981E-01 6.4878E-03 Accumulated dose (rem) 6.9906E-04 1.8981E-01 6.4878E-03 Control Room Doses:
Time (h) = 72.0036 Whole Body Thyroid TEDE Delta dose (rem) 2.5519E-07 1.2176E-03 3.7387E-05 Accumulated dose (rem) 2.5519E-07 1.2176E-03 3.7387E-05 Control Room Compartment Nuclide Inventory:
Time (h) = 72.0036 Ci kg Atoms Bq Kr-85 2.0817E-02 5.3058E-08 3.7591E+17 7.7022E+08 Kr-85m 3.3667E-06 4.0910E-16 2.8984E+09 1.2457E+05 Kr-88 1.5065E-08 1.2014E-18 8.2219E+06 5.5741E+02 I-131 4.3989E-03 3.5482E-11 1.6311E+14 1.6276E+08 I-133 6.7593E-04 5.9669E-13 2.7017E+12 2.5009E+07 I-135 3.6515E-06 1.0398E-15 4.6383E+09 1.3511E+05 Xe-133 1.0054E+00 5.3711E-09 2.4320E+16 3.7199E+10 Xe-135 2.2653E-03 8.8705E-13 3.9570E+12 8.3816E+07 Control Room Transport Group Inventory:
Overlying Time (h) = 72.0036 Atmosphere Sump Pool Noble gases (atoms) 4.0024E+17 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 9.4518E+13 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) 7.1303E+13 0.OOOOE+00 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 0.0000E+00
CALCULATION NOC-101I-900-EOOO.083 I REV. No. 2 1 PAGE NO.78 Deposition Recirculating Time (h) = 72.0036 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 O.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) O.OOOOE+00 O.OOOOE+00 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 72.0036 Filter Noble gases (atoms) O.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 72.0036 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 72.0036 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 72.5000 Whole Body Thyroid TEDE Delta dose (rem) 4.3151E-01 1.1720E+02 4.0058E+00 Accumulated dose (rem) 4.3551E-01 1. 1829E+02 4.0429E+00 Low Population Zone Doses:
Time (h) = 72.5000 Whole Body Thyroid TEDE Delta dose (rem) 7.5515E-02 2.0510E+01 7.0101E-01 Accumulated dose (rem) 7.6214E-02 2.0700E+01 7.0750E-01 Control Room Doses:
Time (h) = 72.5000 Whole Body Thyroid TEDE Delta dose (rem) 5.2760E-03 2.5188E+01 7.7343E-01 Accumulated dose (rem) 5.2763E-03 2.5190E+01 7.7347E-01 Control Room Compartment Nuclide Inventory:
Time (h) 72.5000 Ci kg Atoms Bq Kr-85 1.5368E+00 3.9169E-06 2.7751E+19 5.6860E+10 Kr-85m 2 .3017E-04 2.7968E-14 1.9815E+11 8.5162E+06 Kr-88 9.8526E-07 7.8574E-17 5.3771E+08 3.6455E+04 I-131 3.2416E-01 2.6147E-09 1.2020E+16 1.1994E+10 I-133 4.9081E-02 4.3327E-11 1.9618E+14 1.8160E+09 1-135 2.5589E-04 7.2866E-14 3.2504E+11 9.4681E+06 Xe-133 7.4017E+01 3.9543E-07 1.7905E+18 2.7386E+12 Xe-135 1.6102E-01 6.3053E-11 2.8127E+14 5.9577E+09 Control Room Transport Group Inventory:
Overlying
I CALCULATION NOC-1 101-900-EOOO-083 I REV. No. 2 1 PAGE NO. 79 Time (h) = 72.5000 Atmosphere Sump Pool Noble gases (atoms) 2.9547E+19 0.OOOOE+00 0.0000E+00 Elemental I (atoms) 6.9776E+15 0.OOOOE+00 0.0000E+00 Organic I (atoms) 5.2638E+15 0.OOOOE+00 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Deposition Recirculating Time (h) = 72.5000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) 0.0000E+00 0.OOOOE+00 Aerosols (kg) 0.0000E+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 72.5000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 72.5000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 72.5000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 74.0000 Whole Body Thyroid TEDE Delta dose (rem) 4.8991E-02 1.3212E+01 4.5189E-01 Accumulated dose (rem) 4.8450E-01 1.3150E+02 4.4948E+00 Low Population Zone Doses:
Time (h) = 74.0000 Whole Body Thyroid TEDE Delta dose (rem) 8.5734E-03 2.3121E+00 7.9082E-02 Accumulated dose (rem) 8.4787E-02 2.3012E+01 7.8658E-01 Control Room Doses:
Time (h) = 74.0000 Whole Body Thyroid TEDE Delta dose (rem) 7.7798E-03 1.1050E+01 3.4477E-01 Accumulated dose (rem) 1.3056E-02 3.6240E+01 1.1182E+00 Control Room Compartment Nuclide Inventory:
Time (h) = 74.0000 Ci kg Atoms Bq Kr-85 1.1834E-01 3.0163E-07 2.1370E+18 4.3786E+09 Kr-85m 1.4054E-05 1.7077E-15 1.2099E+10 5.1998E+05 Kr-88 5.2612E-08 4.1958E-18 2.8713E+07 1.9467E+03 I-131 8.7089E-05 7.0248E-13 3.2293E+12 3.2223E+06 1-133 1.2611E-05 1.1132E-14 5.0407E+10 4.6661E+05 1-135 5.9060E-08 1.6817E-17 7.5019E+07 2.1852E+03 Xe-133 5.6530E+00 3.02OOE-08 1.3675E+17 2.0916E+11
CALCULATIONNOC-1101-900-EOOO-083 T REV. No. 2 1 PAGE NO.80 Xe-135 1.1060E-02 4.3307E-12 1.9319E+13 4.0920E+08 Control Room Transport Group Inventory:
Overlying Time (h) = 74.0000 Atmosphere Sump Pool Noble gases (atoms) 2.2753E+18 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 1.8847E+12 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) 1.4218E+12 0.OOOOE+00 0.0000E+00 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Deposition Recirculating Time (h) = 74.0000 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 5.2992E+15 Organic I (atoms) 0.0000E+00 3.9976E+15 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 74.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 4.5573E+20 Organic I (atoms) 3.4379E+20 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 74.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 74.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 2.2991E+15 Organic I (atoms) 1.7344E+15 Aerosols (kg) 0.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 80.0000 Whole Body Thyroid TEDE Delta dose (rem) 2.6487E-05 0.0000E+00 2.6487E-05 Accumulated dose (rem) 4.8453E-01 1.3150E+02 4.4948E+00 Low Population Zone Doses:
Time (h) = 80.0000 Whole Body Thyroid TEDE Delta dose (rem) 1.9865E-06 0.OOOOE+00 1.9865E-06 Accumulated dose (rem) 8.4789E-02 2.3012E+01 7.8658E-01 Control Room Doses:
Time (h) = 80.0000 Whole Body Thyroid TEDE Delta dose (rem) 4.8848E-04 2.7280E-03 5.7167E-04 Accumulated dose (rem) 1.3545E-02 3.6243E+01 1.1188E+00 Control Room Compartment Nuclide Inventory:
Time (h) = 80.0000 Ci kg Atoms Bq Kr-85 8.9354E-07 2.2775E-12 1.6136E+13 3.3061E+04 Xe-133 4.1298E-05 2.2063E-13 9.9900E+11 1.5280E+06
CALCULATION NOC-I 101-900-EOOO-083 I REV. No. 2 TPAGE NO. 81 Xe-135 5.2849E-08 2.0695E-17 9.2317E+07 1.9554E+03 Control Room Transport Group Inventory:
Overlying Time (h) = 80.0000 Atmosphere Sump Pool Noble gases (atoms) 1.7181E+13 O.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 2.1249E-05 O.OOOOE+00 O.OOOOE+00 Organic I (atoms) 1.6030E-05 0.OOOOE+00 O.OOOOE+00 Aerosols (kg) O.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Deposition Recirculating Time (h) = 80.0000 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 5.3005E+15 Organic I (atoms) 0.OOOOE+00 3.9986E+15 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 80.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 4.5573E+20 Organic I (atoms) 3.4379E+20 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 80.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 80.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 2.2997E+15 Organic I (atoms) 1.7348E+15 Aerosols (kg) O.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 96.0000 Whole Body Thyroid TEDE Delta dose (rem) 1.9243E-10 0.OOOOE+00 1.9243E-10 Accumulated dose (rem) 4.8453E-01 1.3150E+02 4.4948E+00 Low Population Zone Doses:
Time (h) = 96.0000 Whole Body Thyroid TEDE Delta dose (rem) 9.3811E-12 0.OOOOE+00 9.3811E-12 Accumulated dose (rem) 8.4789E-02 2.3012E+01 7.8658E-01 Control Room Doses:
Time (h) = 96.0000 Whole Body Thyroid TEDE Delta dose (rem) 3.5487E-09 2.9985E-20 3.5487E-09 Accumulated dose (rem) 1.3545E-02 3.6243E+01 1.1188E+00 Control Room Compartment Nuclide Inventory:
Time (h) = 96.0000 Ci kg Atoms Bq Control Room Transport Group Inventory:
I CALCULATION NQC-I 10I-900-EOOO-083 I REV. No. 2 I PAGE NO. 82 I Overlying Time (h) = 96.0000 Atmosphere Sump Pool Noble gases (atoms) 3.6913E-01 0.0000E+00 0.OOOOE+00 Elemental I (atoms) 1.3569E-50 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) 1.0236E-50 0.OOOOE+00 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Deposition Recirculating Time (h) = 96.0000 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 0.0000E+00 Elemental I (atoms) 0.OOOOE+00 5.3005E+15 Organic I (atoms) 0.OOOOE+00 3.9986E+15 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 4.5573E+20 Organic I (atoms) 3.4379E+20 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 2.2997E+15 Organic I (atoms) 1.7348E+15 Aerosols (kg) 0.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 168.0000 Whole Body Thyroid TEDE Delta dose (rem) 3.7707E-24 0.OOOOE+00 3.7707E-24 Accumulated dose (rem) 4.8453E-01 1.3150E+02 4.4948E+00 Low Population Zone Doses:
Time (h) = 168.0000 Whole Body Thyroid TEDE Delta dose (rem) 7.5414E-26 O.OOOOE+00 7.5414E-26 Accumulated dose (rem) 8.4789E-02 2.3012E+01 7.8658E-01 Control Room Doses:
Time (h) = 168.0000 Whole Body Thyroid TEDE Delta dose (rem) 8.5077E-23 6.7682E-65 8.5077E-23 Accumulated dose (rem) 1.3545E-02 3.6243E+01 1.1188E+00 Control Room Compartment Nuclide Inventory:
Time (h) = 168.0000 Ci kg Atoms Bq Control Room Transport Group Inventory:
Overlying Time (h) = 168.0000 Atmosphere Sump Pool
I CALCULATION NOC-1101-900-EOOO-083 I REV. No. 2 I PAGE NO.83 l Noble gases (atoms) 1.1284E-62 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 5.6912-254 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) 4.2934-254 0.0000E+00 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Deposition Recirculating Time (h) = 168.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.OOOOE+00 Elemental I (atoms) 0.0000E+00 5.3005E+15 Organic I (atoms) 0.OOOOE+00 3.9986E+15 Aerosols (kg) 0.OOOOE+00 0.0000E+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 168.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 4.5573E+20 Organic I (atoms) 3.4379E+20 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 168.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 168.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 2.2997E+15 Organic I (atoms) 1.7348E+15 Aerosols (kg) 0.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 720.0000 Whole Body Thyroid TEDE Delta dose (rem) 7.7374E-86 0.OOOOE+00 7.7374E-86 Accumulated dose (rem) 4.8453E-01 1.3150E+02 4.4948E+00 Low Population Zone Doses:
Time (h) = 720.0000 Whole Body Thyroid TEDE Delta dose (rem) 3.8687E-88 0.OOOOE+00 3.8687E-88 Accumulated dose (rem) 8.4789E-02 2.3012E+01 7. 8658E-01 Control Room Doses:
Time (h) = 720.0000 Whole Body Thyroid TEDE Delta dose (rem) 2.2404E-84 2.8905-268 2.2404E-84 Accumulated dose (rem) 1.3545E-02 3.6243E+01 1. 1188E+00 Control Room Compartment Nuclide Inventory:
Time (h) = 720.0000 Ci kg Atoms Bq Control Room Transport Group Inventory:
Overlying Time (h) = 720.0000 Atmosphere Sump Pool Noble gases (atoms) 0.OOOOE+00 0.0000E+00 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00
CALCULATION NOC-I 101-900-EOOO-083 I REV. No. 2 l PAGE NO. 84 =
Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Deposition Recirculating Time (h) = 720.0000 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 5.3005E+15 Organic I (atoms) 0.OOOOE+00 3.9986E+15 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 4.5573E+20 Organic I (atoms) 3.4379E+20 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 2.2997E+15 Organic I (atoms) 1.7348E+15 Aerosols (kg) 0.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 792.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.OOOOE+00 0.OOOOE+00 Accumulated dose (rem) 4.8453E-01 1.3150E+02 4.4948E+00 Low Population Zone Doses:
Time (h) = 792.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Accumulated dose (rem) 8.4789E-02 2.3012E+01 7.8658E-01 Control Room Doses:
Time (h) = 792.00 00 Whole Body Thyroid TEDE Delta dose (rem) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Accumulated dose (rem) 1.3545E-02 3.6243E+01 1.1188E+00 Control Room Compartment Nuclide Inventory:
Time (h) = 792.0000 Ci kg Atoms Bq Control Room Transport Group Inventory:
Overlying Time (h) = 792.0000 Atmosphere Sump Pool Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Deposition Recirculating
I CALCULATION NOC-1101-900-EOOOA083 lREV. No. 2 1 PAGE NO.85 Time (h) = 792.0000 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 5.3005E+15 Organic I (atoms) 0.OOOOE+00 3.9986E+15 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 792.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 4.5573E+20 Organic I (atoms) 3.4379E+20 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 792.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 792.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 2.2997E+15 Organic I (atoms) 1.7348E+15 Aerosols (kg) 0.OOOOE+00 334 1-131 Summary Containment Environment Control Room Time (hr) I-131 (Curies) I-131 (Curies) I-131 (Curies) 72.001 6.5355E+01 8.3646E-02 1.0538E-04 72.004 4.2054E+02 3.4959E+00 4.3989E-03 72.400 6.7659E+01 3.5615E+02 3.3229E-01 72.500 4.2673E+01 3.8115E+02 3.2416E-01 72.800 1.0706E+01 4.1309E+02 5.3973E-02 73.100 2.6861E+00 4.2110E+02 9.6581E-03 73.400 6.7390E-01 4.2311E+02 1.8719E-03 73.700 1.6907E-01 4.2362E+02 3.9139E-04 74.000 4.2419E-02 4.2374E+02 8.7089E-05 74.300 4.2373E-02 4.2374E+02 1.2362E-05 74.600 4.2328E-02 4.2374E+02 1.7548E-06 74.900 4.2282E-02 4.2374E+02 2.4910E-07 75.200 4.2236E-02 4.2374E+02 3.5360E-08
- 75. 500 4.2191E-02 4.2374E+02 5.0194E-09
- 75. 800 4.2146E-02 4.2374E+02 7.1250E-10 76.100 4.2100E-02 4.2374E+02 1.0114E-10
- 76. 400 4.2055E-02 4.2374E+02 1.4357E-l1 76.700 4.2010E-02 4.2374E+02 2.0380E-12
- 77. 000 4.1964E-02 4.2374E+02 2.8929E-13 77.300 4.1919E-02 4.2374E+02 4.1065E-14 77.600 4.1874E-02 4.2374E+02 5.8291E-15 77.900 4.1829E-02 4.2374E+02 8.2745E-16 78.200 4.1784E-02 4.2374E+02 1.1746E-16
- 78. 500 4.1739E-02 4.2374E+02 1.6673E-17 78.800 4.1694E-02 4.2374E+02 2.3667E-18 79.100 4.1649E-02 4.2374E+02 3.3596E-19 79.400 4.1604E-02 4.2374E+02 4.7690E-20
I CALCULATION NOC-I 101-900-EOOO-083 lREV. No. 2 l PAGE NO.86 79.700 4.1559E-02 4.2374E+02 6.7696E-21 80.000 4 .1514E-02 4.2374E+02 9.6094E-22 80.300 4.1470E-02 4.2374E+02 1.3641E-22 80.600 4 .1425E-02 4.2374E+02 1.9363E-23 80.900 4.1380E-02 4.2374E+02 2.7486E-24 81.200 4.1336E-02 4.2374E+02 3.9016E-25
- 81. 500 4.1291E-02 4.2374E+02 5.5383E-26 81.800 4.1247E-02 4.2374E+02 7.8617E-27 82.100 4.1202E-02 4.2374E+02 1.1160E-27 82.400 4.1158E-02 4.2374E+02 1.5841E-28 96.000 3.9196E-02 4.2374E+02 5.7935E-67 168.000 3.0263E-02 4.2374E+02 1.8762-270 720.000 4.1664E-03 4.2374E+02 O.OOOOE+00 792.000 3 .2169E-03 4.2374E+02 O.OOOOE+00 Cumulative Dose Summary Exclusion Area Bounda Low Population Zone ControlL Room Time Thyroid TEDE Thyroid TEDE Thyroid TEDE (hr) (rem) (rem) (rem) (rem) (rem) (rem) 72.001 2.5952E-02 8.8702E-04 4.5415E-03 1.5523E-04 5.7730E-06 1.7727E-07 72.004 1.0846E+00 3.7073E-02 1.8981E-01 6.4878E-03 1.2176E-03 3.7387E-05 72.400 1.1053E+02 3.7778E+00 1.9343E+01 6.6111E-01 1.8717E+01 5.7473E-01 72.500 1.1829E+02 4.0429E+00 2.0700E+01 7.0750E-01 2.5190E+01 7.7347E-01 72.800 1.2819E+02 4.3816E+00 2.2434E+01 7.6678E-01 3.4328E+01 1.0555E+00 73.100 1.3068E+02 4.4667E+00 2.2869E+01 7.8166E-01 3.5885E+01 1.1051E+00 73.400 1.3130E+02 4.4880E+00 2.2978E+01 7.8540E-01 3.6171E+01 1.1150E+00 73.700 1.3146E+02 4.4934E+00 2.3005E+01 7.8634E-01 3.6228E+01 1.1175E+00 74.000 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.6240E+01 1.1182E+00 74.300 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.6242E+01 1.1185E+00 74.600 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.6243E+01 1.1187E+00 74.900 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.6243E+01 1.1187E+00 75.200 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.6243E+01 1.1188E+00 75.500 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.6243E+01 1.1188E+00 75.800 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.6243E+01 1.1188E+00 76.100 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.6243E+01 1.1188E+00 76.400 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.6243E+01 1.1188E+00 76.700 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.6243E+01 1.1188E+00 77.000 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.6243E+01 1.1188E+00 77.300 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.6243E+01 1.1188E+00 77.600 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.6243E+01 1.1188E+00 77.900 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.6243E+01 1.1188E+00 78.200 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.6243E+01 1.1188E+00 78.500 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.6243E+01 1.1188E+00 78.800 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.6243E+01 1.1188E+00 79.100 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.6243E+01 1.1188E+00 79.400 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.6243E+01 1.1188E+00 79.700 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.6243E+01 1.1188E+00
- 80. 000 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.6243E+01 1.1188E+00 80.300 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.6243E+01 1.1188E+00 80.600 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.6243E+01 1.1188E+00 80.900 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.6243E+01 1.1188E+00 81.200 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.6243E+01 1.1188E+00 81.500 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.6243E+01 1.1188E+00 81.800 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.6243E+01 1.1188E+00 82.100 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.6243E+01 1.1188E+00 82.400 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.6243E+01 1.1188E+00
- 96. 000 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.6243E+01 1.1188E+00 168. 000 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.6243E+01 1.1188E+00 720.000 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.6243E+01 1.1188E+00 792.000 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.6243E+01 1.1188E+00 Worst Two-Hour Doses Note: All of the dose locations are shown below but the worst two-hour dose is only meaningful for the EAB
CALCULATION NOC-1101-900E000-083 I REV. No. 2 @PAGE NO.87_
dose location. Please disregard the two-hour worst doses for the other dose locations Exclusion Area Boundary Time Whole Body Thyroid TEDE (hr) (rem) (rem) (rem) 72.0 4.8440E-01 1.3147E+02 4.4939E+00 Low Population Zone Time Whole Body Thyroid TEDE (hr) (rem) (rem) (rem) 72.0 8.4771E-02 2.3008E+01 7.8643E-01 Control Room Time Whole Body Thyroid TEDE (hr) (rem) (rem) (rem) 72.0 1.3056E-02 3.6240E+01 1.1182E+00
I CALCULATION NOC-I101-900-EOOO-083 I REV. No. 2 l PAGE NO.88 l Appendix F RADTRAD File OD.psf FHA Occurring In Reactor Building With Hatch Doors Opened CR Recirc Flow: 28,000 cfm CR Filtered Intake Flow: 8,800 cfm CR Unfiltered Inleakage: 1,000 cfm CR Exhaust Flow: 9,800 cfm Two Times Iodine & Noble Gas Release Fractions
I CALCULATION NOC-110I-900-EOOO-083 I REV. No. 2 I PAGE NO.89
- i#i###i########### #####iff#ifi########ifff##########i#i#i##########if##i##i#####if#i###
RADTRAD Version 3.02 run on 7/07/2005 at 7:53:39
- F#ile #infor## ####### #########f#################
ii#i######fi######i####fi##f#####fi#######i###fii####fi###########if###f#####fi#######ii#####
File information
- i#####iffii###############iifi#####f###i##i##i###i########if#i### i#############fifi#######
Plant file name = C:\Program Files\U S Nuclear Regulatory Commission\Radtrad\OD.psf Inventory file name = c:\program files\u s nuclear regulatory commission\radtrad\defaults\fharb_defa.nif Scenario file name = C:\Program Files\U S Nuclear Regulatory Commission\Radtrad\OD.psf Release file name = c:\program files\u s nuclear regulatory commission\radtrad\defaults\fha update 6-9-05.rft Dose conversion file name = c:\program files\u s nuclear regulatory commission\radtrad\defaults\fgrll&12.inp ififififif ifififif ififif#if if # if ififififif if if if if ifif if if #
if ifif if if## ifif if ifif#ifif if##if #ifif# # if if if ififififif if if if if if ifif #
if # if # if ifif if if### # ifif # if Radtrad 3.02 1/5/2000 TMI-1 FHAIC With Hatch Doors Opened, AST Analysis, CR Charcoal Filter Efficiency =
75%., CR Recirc = 28,000 cfm, CR Intake = 8,800 cfm Nuclide Inventory File:
c:\program files\u s nuclear regulatory commission\radtrad\defaults\fharb_def_a.nif Plant Power Level:
2.6190E+03 Compartments:
3 Compartment 1:
Containment 3
2.1600E+06 0
0 0
0 0
Compartment 2:
Environment 2
O.OOOOE+00 0
0 0
0 0
Compartment 3:
Control Room 1
2.5000E+05 0
0 1
0
CALCULATION NOC-I 10 I-900-EOOO-083 I REV. No. 2 T PAGE NO. 90 0
Pathways:
4 Pathway 1:
Containment to Environment 1
2 2
Pathway 2:
Control Room Air Intake 2
3 2
Pathway 3:
Control Room Unfiltered Inleakage 2
3 2
Pathway 4:
Control Room Exhaust to Environment 3
2 2
End of Plant Model File Scenario Description Name:
Plant Model Filename:
Source Term:
1 1 1.0000E+00 c:\program files\u s nuclear regulatory commission\radtrad\defaults\fgrll&12.inp c:\program files\u s nuclear regulatory commission\radtrad\defaults\fha update 6 05.rft 7.2000E+01 0
0.OOOOE+00 5.7000E-01 4.3000E-01 1.OOOOE+00 Overlying Pool:
0 o.0000E+00 0
0 0
0 Compartments:
3 Compartment 1:
0 1
0 0
0 0
0 0
0 Compartment 2:
0 1
0 0
0 0
0 0
0 Compartment 3:
1
I CALCULATION NOC-1 101-900-EOOO-083 - REV. No. 2 I PAGE NO. 91 1
0 0
0 0
1 2.8000E+04 3
7 .2000E+01 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 7 .2500E+01 9.9000E+O1 7.5000E+01 7.5000E+O1 7 .9200E+02 9.9000E+01 7.5000E+01 7.5000E+O1 0
0 Pathways:
4 Pathway 1:
0 0
0 0
0 1
3 7 .2000E+01 1.6580E+05 O.OOOOE+OO O.OOOOE+00 O.OOOOE+O0 7 .4000E+01 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00
- 7. 9200E+02 O.OOOOE+O0 O.OOOOE+00 O.OOOOE+0O O.OOOOE+00 0
0 0
0 0
0 Pathway 2:
0 0
0 0
0 1
3 7 .2000E+01 4.0000E+03 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 7 .2500E+01 8.8000E+03 9.9000E+01 7.5000E+01 7.5000E+01 7 .9200E+02 O.OOOOE+00 O.OOOOE+00 O.OOOOE+OO O.OOOOE+00 0
0 0
0 0
0 Pathway 3:
0 0
0 0
0 1
2
- 7. 2000E+01 l.OOOOE+03 O.OOOOE+0O O.OOOOE+00 O.OOOOE+O0
- 7. 9200E+02 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 0
0 0
0 0
0 Pathway 4:
0 0
CALCULATION NOC-I 10I-900-EOOO-083 l REV.No. 2 I PAGE NO.92 0
0 0
1 3
7.2000E+01 5.0000E+03 O.OOOOE+00 O.OOOOE+00 0.0000E+00 7.2500E+01 9.8000E+03 1.OOOOE+02 1.OOOOE+02 1.0000E+02 7.9200E+02 3.0000E+00 O.OOOOE+00 O.OOOOE+00 0.0000E+00 0
0 0
0 0
0 Dose Locations:
3 Location 1:
Exclusion Area Boundary 2
1 2
7.2000E+01 8.0000E-04 7.2000E+02 O.OOOOE+00 1
2 7.2000E+01 3.5000E-04 7.2000E+02 O.OOOOE+00 0
Location 2:
Low Population Zone 2
1 6
7.2000E+01 1.4000E-04 7.4000E+01 6.OOOOE-05 8.0000E+01 3.9000E-05 9.6000E+01 1.6000E-05 1.6800E+02 4.OOOOE-06 7.9200E+02 O.OOOOE+00 1
4 7.2000E+01 3.5000E-04 8.0000E+01 1.8000E-04 9.6000E+01 2.3000E-04 7.9200E+02 O.OOOOE+00 0
Location 3:
Control Room 3
0 1
2 7.2000E+01 3.5000E-04 7.9200E+02 O.OOOOE+00 1
4 7.2000E+01 1.0000E+00 9.6000E+01 6.0000E-01 1.6800E+02 4.0000E-01 7.9200E+02 O.OOOOE+00 Effective Volume Location:
1 6
7.2000E+01 5.3400E-04 7.4000E+01 3.1000E-04
- 8. 0000E+01 1.3600E-04 9.6000E+01 9.7000E-05 1.6800E+02 6.0200E-05
CALCULATION NOC- 101-900-EOOO-083 TREV. No. 2 l PAGE NO. 93 7.9200E+02 O.OOOOE+00 Simulation Parameters:
6 7.2000E+01 l.OOOOE-01 7.4000E+01 5.0000E-01 8.OOOOE+01 1.OOOOE+00 9.6000E+01 2.0000E+O0 1.6800E+02 4.0000E+00 7.9200E+02 O.OOOOE+00 Output Filename:
C:\Program Files\U S Nuclear Regulatory Commission\Radtrad\0D.ol 1
1 0
0 End of Scenario File RADTRAD Version 3.02 run on 7/07/2005 at 7:53:39 Plant Description Number of Nuclides = 60 Inventory Power = 1.OOOOE+00 MWth Plant Power Level = 2.6190E+03 MWth Number of compartments = 3 Compartment information Compartment number 1 (Source term fraction 1.0000E+0O
)
Name: Containment Compartment volume = 2.1600E+06 (Cubic feet)
Pathways into and out of compartment 1 Pathway to compartment number 2: Containment to Environment Compartment number 2 Name: Environment Pathways into and out of compartment 2 Pathway to compartment number 3: Control Room Air Intake Pathway to compartment number 3: Control Room Unfiltered Inleakage Pathway from compartment number 1: Containment to Environment Pathway from compartment number 3: Control Room Exhaust to Environment Compartment number 3 Name: Control Room Compartment volume = 2.5000E+05 (Cubic feet)
Removal devices within compartment:
Filter(s)
Pathways into and out of compartment 3 Pathway to compartment number 2: Control Room Exhaust to Environment Pathway from compartment number 2: Control Room Air Intake Pathway from compartment number 2: Control Room Unfiltered Inleakage Total number of pathways = 4 RADTRAD Version 3.02 run on 7/07/2005 at 7:53:39
CALCULATION NOC-1 101-900-EOOO-083 I REV. No. 2 1 PAGE NO.94 l Scenario Description Time between shutdown and first release = 7.2000E+01 (Hours)
Radioactive Decay is enabled RELEASENAME = RG-1.183, Tables 3 Section 3.2 Release Fractions and Timings GAP EARLY IN-VESSEL 0.0036 hrs 0.0000 hrs NOBLES 1.OOOOE-01 0.OOOOE+00 IODINE 1.OOOOE-01 0.OOOOE+00 CESIUM 0.OOOOE+00 0.OOOOE+00 TELLURIUM 0.OOOOE+00 0.OOOOE+00 STRONTIUM 0.OOOOE+00 0.OOOOE+00 BARIUM 0.OOOOE+00 0.OOOOE+00 RUTHENIUM 0.OOOOE+00 0.OOOOE+00 CERIUM 0.OOOOE+00 0.OOOOE+00 LANTHANUM 0.OOOOE+00 0.OOOOE+00 Iodine fractions Aerosol 0.OOOOE+00 Elemental 5.7000E-01 Organic 4.30OOE-01 COMPARTMENT DATA Compartment number 1: Containment Compartment number 2: Environment Compartment number 3: Control Room Compartment Filter Data Time (hr) Flow Rate Filter Efficiencies (%)
(cfm) Aerosol Elemental Organic 7.2000E+01 2.8000E+04 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 7.2500E+01 2.8000E+04 9.9000E+01 7.5000E+01 7.5000E+01 7.9200E+02 2.8000E+04 9.9000E+01 7.5000E+01 7.5000E+01 PATHWAY DATA Pathway number 1: Containment to Environment Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)
(cfm) Aerosol Elemental Organic 7.2000E+01 1.6580E+05 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 7.4000E+01 0.OOOOE+00 0.0000E+00 0.0000E+00 0.0000E+00 7.9200E+02 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.0000E+00 Pathway number 2: Control Room Air Intake Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)
(cfm) Aerosol Elemental Organic 7.2000E+01 4.OOOOE+03 0.0000E+00 0.OOOOE+00 0.OOOOE+00 7.2500E+01 8.8000E+03 9.9000E+01 7.5000E+01 7.5000E+01 7.9200E+02 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Pathway number 3: Control Room Unfiltered Inleakage Pathway Filter: Removal Data
I CALCULATION NOC-l 101-900-EOOO-083 I REV. No. 2 l PAGE NO.95 Time (hr) Flow Rate Filter Efficiencies (%)
(cfm) Aerosol Elemental Organic 7.2000E+01 1.0000E+03 O.OOOOE+00 0.OOOOE+00 0.OOOOE+00 7.9200E+02 0.000OE+00 O.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Pathway number 4: Control Room Exhaust to Environment Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)
(cfm) Aerosol Elemental Organic 7.2000E+01 5.OOOOE+03 0.OOOOE+00 O.OOOOE+00 0.OOOOE+00 7.2500E+01 9.8000E+03 1.OOOOE+02 1.OOOOE+02 1.OOOOE+02 7.9200E+02 3.OOOOE+00 0.OOOOE+00 O.OOOOE+00 0.OOOOE+00 LOCATION DATA Location Exclusion Area Boundary is in compartment 2 Location X/Q Data Time (hr) X/Q (s
- m^-3) 7.2000E+01 8.OOOOE-04 7.2000E+02 0.OOOOE+00 Location Breathing Rai te Data Time (hr) Br4eathing Rate (m^3
- secA-1) 7.2000E+01 3.5000E-04 7.2000E+02 O.OOOOE+00 Location Low Populaticon Zone is in compartment 2 Location X/Q Data Time (hr) X/S' (s
- m^-3) 7.2000E+01 1.4000E-04 7.4000E+01 6.OOOOE-05 8.OOOOE+01 3.9000E-05 9.6000E+01 1.6000E-05 1.6800E+02 4.OOOOE-06 7.9200E+02 0.0000E+00 Location Breathing Rai:e Dzata Time (hr) BroeathiLng Rate (m^3
- seic^-1) 7.2000E+01 3.5000E-04 8.OOOOE+01 1.8000E-04 9.6000E+01 2.30OOE-04 7.9200E+02 0.OOOOE+00 Location Control Room is in compartment 3 Location X/Q Data Time (hr) X/SQ (s
- m^-3) 7.2000E+01 5.3400E-04 7.4000E+01 3.1000E-04 8.OOOOE+01 1.3600E-04 9.6000E+01 9.7000E-05 1.6800E+02 6.0200E-05 7.9200E+02 0.OOOOE+00 Location Breathing Rai:e Data Time (hr) Br4eathing Rate (m^3
- secA-1) 7.2000E+01 3.5000E-04 7.9200E+02 0.OOOOE+00 Location Occupancy Fac:tor Data Time (hr) Oc(:upancy Factor 7.2000E+01 1.OOOOE+00 9.6000E+01 6.0000E-01 1.6800E+02 4.0000E-01 7.9200E+02 0.0000E+00
I CALCULATION NOC-1101-900-EOOO-083 7 REV. No. 2 1 PAGE NO.96 USER SPECIFIED TIME STEP DATA - SUPPLEMENTAL TIME STEPS Time Time step 0.0000E+00 1.0000E-01 2.0000E+00 5.0000E-01 8.0000E+00 1.OOOOE+00 2.4000E+01 2.OOOOE+00 9.6000E+01 4.OOOOE+00 7.2000E+02 0.OOOOE+00 RADTRAD Version 3.02 run on 7/07/2005 at 7:53:39
- fi # #f i##### #####ifi# if #i####
- f # # #f #f #f # if# i#
- f # # # #f #f #i # # i#
- f # #f #f if #####i #f if #
- f # # # # if if if #
- f if # # # if # if if
- fi ####fi # if i#### #f Dose, Detailed model and Detailed Inventory Output Exclusion Area Boundary Doses:
Time (h) = 72.0036 Whole Body Thyroid TEDE Delta dose (rem) 3.9946E-03 1.0846E+00 3.7073E-02 Accumulated dose (rem) 3.9946E-03 1.0846E+00 3.7073E-02 Low Population Zone Doses:
Time (h) = 72.0036 Whole Body Thyroid TEDE Delta dose (rem) 6.9906E-04 1. 8981E-01 6.4878E-03 Accumulated dose (rem) 6.9906E-04 1. 8981E-01 6.4878E-03 Control Room Doses:
Time (h) = 72.0036 Whole Body Thyroid TEDE Delta dose (rem) 2.5519E-07 1.2176E-03 3.7387E-05 Accumulated dose (rem) 2.5519E-07 1.2176E-03 3.7387E-05 Control Room Compartment Nuclide Inventory:
Time (h) 72.0036 Ci kg Atoms Bq Kr-85 2.0817E-02 5.3058E-08 3.7591E+17 7.7022E+08 Kr-85m 3.3667E-06 4.0910E-16 2.8984E+09 1.2457E+05 Kr-88 1.5065E-08 1.2014E-18 8.2219E+06 5.5741E+02 I-131 4.3989E-03 3.5482E-11 1.6311E+14 1.6276E+08 I-133 6.7593E-04 5.9669E-13 2.7017E+12 2.5009E+07 I-135 3. 6515E-06 1.0398E-15 4.6383E+09 1.3511E+05 Xe-133 1.0054E+00 5.3711E-09 2.4320E+16 3.7199E+10 Xe-135 2.2653E-03 8.8705E-13 3.9570E+12 8.3816E+07 Control Room Transport Group Inventory:
Overlying Time (h) = 72.0036 Atmosphere Sump Pool Noble gases (atoms) 4.0024E+17 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 9.4518E+13 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) 7.1303E+13 0.OOOOE+00 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00
I CALCULATION NOC-l 101-900-EOOO-083 REV. No. 2 PAGE NO. 97 Deposition Recirculating Time (h) = 72.0036 Surfaces Filter Noble gases (atoms) O.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.0066E+00 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 0.OOOOE+00 Aerosols (kg) O.OOOOE+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 72.0036 Filter Noble gases (atoms) O.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 72.0036 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 72.0036 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 72.5000 Whole Body Thyroid TEDE Delta dose (rem) 4.3151E-01 1.1720E+02 4.0058E+00 Accumulated dose (rem) 4.3551E-01 1.1829E+02 4.0429E+00 Low Population Zone Doses:
Time (h) = 72.5000 Whole Body Thyroid TEDE Delta dose (rem) 7.5515E-02 2.0510E+01 7.0101E-01 Accumulated dose (rem) 7.6214E-02 2.0700E+01 7.0750E-01 Control Room Doses:
Time (h) = 72.5000 Whole Body Thyroid TEDE Delta dose (rem) 5.2760E-03 2.5188E+01 7.7343E-01 Accumulated dose (rem) 5.2763E-03 2.5190E+01 7.7347E-01 Control Room Compartment Nuclide Inventory:
Time (h) = 72.5000 Ci kg Atoms Bq Kr-85 1.5368E+00 3.9169E-06 2.7751E+19 5.6860E+10 Kr-85m 2.3017E-04. 2.7968E-14 1.9815E+11 8.5162E+06 Kr-88 9.8526E-07 7.8574E-17 5.3771E+08 3.6455E+04 1-131 3 .2416E-01 2.6147E-09 1.2020E+16 1.1994E+10 I-133 4.9081E-02 4.3327E-11 1.9618E+14 1.8160E+09 I-135 2.5589E-04 7.2866E-14 3.2504E+11 9.4681E+06 Xe-133 7.4017E+01 3.9543E-07 1.7905E+18 2.7386E+12 Xe-135 1.6102E-01 6.3053E-11 2.8127E+14 5.9577E+09 Control Room Transport Group Inventory:
Overlying
I CALCULATION NOC-1101-900-EOOO-083 I REV. No. 2 I PAGE NO.98 l Time (h) = 72.5000 Atmosphere Sump Pool Noble gases (atoms) 2.9547E+19 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 6.9776E+15 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) 5.2638E+15 0.OOOOE+00 0.OOOOE+00 Aerosols (kg) 0.0000E+00 O.OOOOE+00 0.OOOOE+00 Deposition Recirculating Time (h) = 72.5000 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 72.5000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 72.5000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 72.5000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.0000E+00 Exclusion Area Boundary Doses:
Time (h) = 74.0000 Whole Body Thyroid TEDE Delta dose (rem) 4.9020E-02 1.3212E+01 4.5192E-01 Accumulated dose (rem) 4.8453E-01 1.3150E+02 4.4948E+00 Low Population Zone Doses:
Time (h) = 74.0000 Whole Body Thyroid TEDE Delta dose (rem) 8.5784E-03 2.3121E+00 7.9087E-02 Accumulated dose (rem) 8.4792E-02 2.3012E+01 7.8659E-01 Control Room Doses:
Time (h) = 74.0000 Whole Body Thyroid TEDE Delta dose (rem) 6.9609E-03 9.9205E+00 3.0950E-01 Accumulated dose (rem) 1.2237E-02 3.5110E+01 1.0830E+00 Control Room Compartment Nuclide Inventory:
Time (h) = 74.0000 Ci kg Atoms Bq Kr-85 7.4669E-02 1.9032E-07 1.3484E+18 2.7627E+09 Kr-85m 8.8673E-06 1.0775E-15 7.6339E+09 3.2809E+05 Kr-88 3.3197E-08 2.6474E-18 1.8117E+07 1.2283E+03 I-131 6.0609E-05 4.8888E-13 2.2474E+12 2.2425E+06 I-133 8.7764E-06 7.7475E-15 3.5080E+10 3.2473E+05 I-135 4.1102E-08 1.1704E-17 5.2209E+07 1.5208E+03 Xe-133 3.5668E+00 1.9055E-08 8.6282E+16 1.3197E+11
CALCULATION NOC-I101-900-EOOO-083 - REV. No. 2 I PAGE NO.99 l Xe-135 6.9782E-03 2.7326E-12 1.2189E+13 2.5819E+08 Control Room Transport Group Inventory:
overlying Time (h) = 74.0000 Atmosphere Sump Pool Noble gases (atoms) 1.4357E+18 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 1.3117E+12 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) 9.8950E+11 0.OOOOE+00 0.OOODE+00 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Deposition Recirculating Time (h) = 74.0000 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 5.2358E+15 Organic I (atoms) 0.OOOOE+00 3.9498E+15 Aerosols (kg) 0.0000E+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 74.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 5.5700E+20 Organic I (atoms) 4.2019E+20 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 74.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 74.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 2.4434E+15 Organic I (atoms) 1.8433E+15 Aerosols (kg) 0.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 80.0000 Whole Body Thyroid TEDE Delta dose (rem) 1.6725E-05 0.OOOOE+00 1.6725E-05 Accumulated dose (rem) 4.8454E-01 1.3150E+02 4.4948E+00 Low Population Zone Doses:
Time (h) = 80.0000 Whole Body Thyroid TEDE Delta dose (rem) 1.2544E-06 0.OOOOE+00 1.2544E-06 Accumulated dose (rem) 8.4794E-02 2.3012E+01 7.8659E-01 Control Room Doses:
Time (h) = 80.0000 Whole Body Thyroid TEDE Delta dose (rem) 2.5845E-04 1.6869E-03 3.0989E-04 Accumulated dose (rem) 1.2496E-02 3.5112E+01 1.0833E+00 Control Room Compartment Nuclide Inventory:
Time (h) = 80.0000 Ci kg Atoms Bq Kr-85 5.6642E-08 1.4437E-13 1.0229E+12 2.0958E+03 Xe-133 2.6179E-06 1.3986E-14 6.3328E+10 9.6864E+04
CALCULATION NOC-I 101-900-EOOO-083 I REV. No. 2 I PAGE NO. 100 l Xe-135 3.3502E-09 1.3119E-18 5.8521E+06 1.2396E+02 Control Room Transport Group Inventory:
Overlying Time (h) = 80.0000 Atmosphere Sump Pool Noble gases (atoms) 1.0891E+12 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 7.1778E-08 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) 5.4148E-08 0.0000E+00 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Deposition Recirculating Time (h) = 80.0000 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 5.2367E+15 Organic I (atoms) 0.OOOOE+00 3.9505E+15 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 80.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 5.5700E+20 Organic I (atoms) 4.2019E+20 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 80.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 80.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 2.4438E+15 Organic I (atoms) 1.8436E+15 Aerosols (kg) 0.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 96.0000 Whole Body Thyroid TEDE Delta dose (rem) 1.2206E-11 0.OOOOE+00 1.2206E-11 Accumulated dose (rem) 4.8454E-01 1.3150E+02 4.4948E+00 Low Population Zone Doses:
Time (h) = 96.0000 Whole Body Thyroid TEDE Delta dose (rem) 5.9504E-13 0.OOOOE+00 5.9504E-13 Accumulated dose (rem) 8.4794E-02 2.3012E+01 7.8659E-01 Control Room Doses:
Time (h) = 96.0000 Whole Body Thyroid TEDE Delta dose (rem) 1.8860E-10 8.9997E-23 1.8860E-10 Accumulated dose (rem) 1.2496E-02 3.5112E+01 1.0833E+00 Control Room Compartment Nuclide Inventory:
Time (h) = 96.0000 Ci kg Atoms Bq Control Room Transport Group Inventory:
CALCULATION NOC-I 101-900-E000-083 I REV. No. 2 _lPAGE NO. 101 l Overlying Time (h) = 96.0000 Atmosphere Sump Pool Noble gases (atoms) 5.0579E-05 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 3.0900E-59 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) 2.3310E-59 0.0000E+00 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Deposition Recirculating Time (h) = 96.0000 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) O.0000E+00 5.2367E+15 Organic I (atoms) O.OOOOE+00 3.9505E+15 Aerosols (kg) 0.0000E+00 0.0000E+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 5.5700E+20 Organic I (atoms) 4.2019E+20 Aerosols (kg) O.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 2.4438E+15 Organic I (atoms) 1.8436E+15 Aerosols (kg) 0.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 168.0000 Whole Body Thyroid TEDE Delta dose (rem) 5.1678E-28 0.OOOOE+00 5.1678E-28 Accumulated dose (rem) 4.8454E-01 1.3150E+02 4.4948E+00 Low Population Zone Doses:
Time (h) = 168.0000 Whole Body Thyroid TEDE Delta dose (rem) 1.0336E-29 0.OOOOE+00 1.0336E-29 Accumulated dose (rem) 8.4794E-02 2.3012E+01 7.8659E-01 Control Room Doses:
Time (h) = 168.0000 Whole Body Thyroid TEDE Delta dose (rem) 1.1417E-26 1.5413E-73 1.1417E-26 Accumulated dose (rem) 1.2496E-02 3.5112E+01 1.0833E+00 Control Room Compartment Nuclide Inventory:
Time (h) = 168.0000 Ci kg Atoms Bq Control Room Transport Group Inventory:
Overlying Time (h) = 168.0000 Atmosphere Sump Pool
CALCULATION NOC-I 10 I-900-EOOO-083 _ FREV. No. 2 1 PAGE NO. 102 l Noble gases (atoms) 1.5550E-78 0.OOOOE+00 O.OOOOE+00 Elemental I (atoms) 2. 1902-290 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) 1.6523-290 0.OOOOE+00 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Deposition Recirculating Time (h) = 168.0000 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 5.2367E+15 Organic I (atoms) 0.OOOOE+00 3.9505E+15 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 168.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 5.5700E+20 Organic I (atoms) 4.2019E+20 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 168.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 168.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 2.4438E+15 Organic I (atoms) 1.8436E+15 Aerosols (kg) 0.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 720.0000 Whole Body Thyroid TEDE Delta dose (rem) 1.0663-101 0.OOOOE+00 1.0663-101 Accumulated dose (rem) 4.8454E-01 1.3150E+02 4. 4948E+00 Low Population Zone Doses:
Time (h) = 720.0000 Whole Body Thyroid TEDE Delta dose (rem) 5.3315-104 0.OOOOE+00 5.3315-104 Accumulated dose (rem) 8.4794E-02 2.3012E+01 7.8659E-01 Control Room Doses:
Time (h) = 720.0000 Whole Body Thyroid TEDE Delta dose (rem) 3.0855-100 1.1124-304 3.0855-100 Accumulated dose (rem) 1.2496E-02 3.5112E+01 1.0833E+00 Control Room Compartment Nuclide Inventory:
Time (h) = 720.0000 Ci kg Atoms Bq Control Room Transport Group Inventory:
Overlying Time (h) = 720.0000 Atmosphere Sump Pool Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 0.0000E+00 Elemental I (atoms) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00
I CALCULATION NOC-1 101-900-E000-083 l REV. No. 2 l PAGE NO. 103 l Aerosols (kg) O.OOOOE+00 0.OOOOE+00 O.OOOOE+00 Deposition Recirculating Time (h) = 720.0000 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 0.00 E+00 Elemental I (atoms) 0.OOOOE+00 5.2367E+15 Organic I (atoms) 0.OOOOE+00 3.9505E+15 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 5.5700E+20 Organic I (atoms) 4.2019E+20 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 2.4438E+15 Organic I (atoms) 1.8436E+15 Aerosols (kg) 0.0000E+00 Exclusion Area Boundary Doses:
Time (h) = 792.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Accumulated dose (rem) 4.8454E-01 1.3150E+02 4.4948E+00 Low Population Zone Doses:
Time (h) = 792.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Accumulated dose (rem) 8.4794E-02 2.3012E+01 7.8659E-01 Control Room Doses:
Time (h) = 792.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Accumulated dose (rem) 1.2496E-02 3.5112E+01 1.0833E+00 Control Room Compartment Nuclide Inventory:
Time (h) = 792.0000 Ci kg Atoms Bq Control Room Transport Group Inventory:
Overlying Time (h) = 792.0000 Atmosphere Sump Pool Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 0.0000E+00 0.OOOOE+00 Deposition Recirculating
CALCULATION NOC-1 10I-900-EOOO-083 I REV. No. 2 l PAGE NO. 104 Time (h) = 792.0000 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.0ooOE+00 5.2367E+15 Organic I (atoms) 0.OOOOE+00 3.9505E+15 Aerosols (kg) O.OOOOE+00 0.0000E+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 792.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 5.5700E+20 Organic I (atoms) 4.2019E+20 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 792.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 792.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 2.4438E+15 Organic I (atoms) 1.8436E+15 Aerosols (kg) O.OOOOE+00 334 I-131 Summary Containment Environment Control Room Time (hr) 1-131 (Curies) I-131 (Curies) I-131 (Curies) 72.001 6.5355E+01 8.3646E-02 1.0538E-04 72.004 4.2054E+02 3.4959E+00 4.3989E-03 72.400 6.7659E+01 3.5615E+02 3.3229E-01 72.500 4.2673E+01 3.8115E+02 3.2416E-01 72.800 1.0706E+01 4.1309E+02 4.3338E-02 73.100 2.6861E+00 4.2110E+02 6.7416E-03 73.400 6.7390E-01 4.2311E+02 1.2421E-03 73.700 1.6907E-01 4.2362E+02 2.6276E-04 74.000 4.2419E-02 4.2374E+02 6.0609E-05 74.300 4.2373E-02 4.2374E+02 6.5914E-06 74.600 4.2328E-02 4.2374E+02 7.1683E-07 74.900 4.2282E-02 4.2374E+02 7.7957E-08 75.200 4.2236E-02 4.2374E+02 8.4781E-09 75.500 4.2191E-02 4.2374E+02 9.2201E-10 75.800 4.2146E-02 4.2374E+02 1.0027E-10
- 76. 100 4.2100E-02 4.2374E+02 1.0905E-11
- 76. 400 4.2055E-02 4.2374E+02 1.1859E-12 76.700 4.2010E-02 4.2374E+02 1.2897E-13 77.000 4.1964E-02 4.2374E+02 1.4026E-14 77.300 4.1919E-02 4.2374E+02 1.5254E-15 77.600 4.1874E-02 4.2374E+02 1.6589E-16 77.900 4.1829E-02 4.2374E+02 1.8041E-17 78.200 4.1784E-02 4.2374E+02 1.9620E-18 78.500 4.1739E-02 4.2374E+02 2.1337E-19
- 78. 800 4.1694E-02 4.2374E+02 2.3205E-20 79.100 4.1649E-02 4.2374E+02 2.5236E-21 79.400 4.1604E-02 4.2374E+02 2.7445E-22
I CALCULATION NOC-1 101-900-EOOO-083 I REV. No. 2 T PAGE NO. 105 79.700 4.1559E-02 4.2374E+02 2.9847E-23 80.000 4.1514E-02 4.2374E+02 3.2460E-24 80.300 4.1470E-02 4.2374E+02 3.5301E-25
- 80. 600 4.1425E-02 4.2374E+02 3.8391E-26 80.900 4.1380E-02 4.2374E+02 4.1751E-27 81.200 4.1336E-02 4.2374E+02 4.5405E-28 81.500 4.1291E-02 4.2374E+02 4.9380E-29
- 81. 800 4.1247E-02 4.2374E+02 5.3702E-30 82.100 4.1202E-02 4.2374E+02 5.8402E-31 82.400 4.1158E-02 4.2374E+02 6.3514E-32 96.000 3.9196E-02 4.2374E+02 1.3193E-75 168.000 3.0263E-02 4.2374E+02 7.2203-307 720.000 4.1664E-03 4.2374E+02 O.OOOOE+00 792.000 3.2169E-03 4.2374E+02 O.OOOOE+00 Cumulative Dose Summary Exclusion Area Bounda Low Population Zone Contro:l Room Time Thyroid TEDE Thyroid TEDE Thyroid TEDE (hr) (rem) (rem) (rem) (rem) (rem) (rem) 72.001 2.5952E-02 8.8702E-04 4.5415E-03 1.5523E-04 5.7730E-06 1.7727E-07 72.004 1.0846E+00 3.7073E-02 1.8981E-01 6.4878E-03 1.2176E-03 3.7387E-05 72.400 1.1053E+02 3.7778E+00 1.9343E+01 6.6111E-01 1.8717E+01 5.7473E-01 72.500 1.1829E+02 4.0429E+00 2.0700E+01 7.0750E-01 2.5190E+01 7.7347E-01 72.800 1.2819E+02 4.3816E+00 2.2434E+01 7.6679E-01 3.3682E+01 1.0357E+00 73.100 1.3068E+02 4.4667E+00 2.2869E+01 7. 8167E-01 3.4869E+01 1.0738E+00 73.400 1.3130E+02 4.4881E+00 2.2978E+01 7. 8541E-01 3.5064E+01 1.0808E+00 73.700 1.3146E+02 4.4934E+00 2.3005E+01 7.8635E-01 3.5102E+01 1.0825E+00 74.000 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5110E+01 1.0830E+00 74.300 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5112E+01 1. 0831E+00 74.600 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5112E+01 1.0832E+00 74.900 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5112E+01 1.0832E+00 75.200 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5112E+01 1.0833E+00 75.500 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5112E+01 1.0833E+00 75.800 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5112E+01 1.0833E+00 76.100 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5112E+01 1.0833E+00 76.400 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5112E+01 1.0833E+00 76.700 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5112E+01 1.0833E+00 77.000 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5112E+01 1.0833E+00 77.300 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5112E+01 1.0833E+00 77.600 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5112E+01 1.0833E+00 77.900 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5112E+01 1.0833E+00 78.200 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5112E+01 1.0833E+00 78.500 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5112E+01 1.0833E+00 78.800 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5112E+01 1.0833E+00 79.100 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5112E+01 1.0833E+00 79.400 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5112E+01 1.0833E+00 79.700 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5112E+01 1.0833E+00 80.000 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5112E+01 1.0833E+00 80.300 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5112E+01 1.0833E+00 80.600 1.3150E+02 4.4948E+00 2.3012E+01 7. 8659E-01 3.5112E+01 1.0833E+00 80.900 1.3150E+02 4.4948E+00 2.3012E+01 7. 8659E-01 3.5112E+01 1.0833E+00 81.200 1.3150E+02 4.4948E+00 2.3012E+01 7. 8659E-01 3.5112E+01 1.0833E+00 81.500 1.3150E+02 4.4948E+00 2.3012E+01 7. 8659E-01 3.5112E+01 1.0833E+00 81.800 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5112E+01 1.0833E+00 82.100 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5112E+01 1.0833E+00 82.400 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5112E+01 1.0833E+00 96.000 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5112E+01 1.0833E+00 168.000 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5112E+01 1.0833E+00 720.000 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3. 5112E+01 1.0833E+00 792.000 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5112E+01 1.0833E+00 Worst Two-Hour Doses Note: All of the dose locations are shown below but the worst two-hour dose is only meaningful for the EAB
ICALCULATION NOC-1 101-900-EOOO-083 I REV. No. 2 l PAGE NO. 106 dose location. Please disregard the two-hour worst doses for the other dose locations Exclusion Area Boundary Time Whole Body Thyroid TEDE (hr) (rem) (rem) (rem) 72.0 4.8443E-01 1.3147E+02 4.4939E+00 Low Population Zone Time Whole Body Thyroid TEDE (hr) (rem) (rem) (rem) 72.0 8.4776E-02 2.3008E+01 7.8643E-01 Control Room Time Whole Body Thyroid TEDE (hr) (rem) (rem) (rem) 72.0 1.2237E-02 3.5110E+01 1.0830E+00
CALCULATION NOC-1 101-900-EOOO-083 l REV. No. 2 l PAGE NO. 107 Appendix G RADTRAD File OE.psf FHA Occurring In Reactor Building With Hatch Doors Opened CR Recirc Flow: 28,000 cfm CR Filtered Intake Flow: 8,000 cfm CR Unfiltered Inleakage: 1,000 cfm CR Exhaust Flow: 9,000 cf'm Two Times Iodine & Noble Gas Release Fractions
II REV. No. 22 I PAGE NO. 108 I CALCULATION NQC-1 1O1-900-EOOO..083 CALCULATION NOC-ll 0lI-900-EOOO-083 REV.No. I PAGE NO.l108 I RADTRAD Version 3.02 run on 7/07/2005 at 7:53:39
- l####o#ra## #########################
File information
- ffii#####i####fi######fi######f#####f########i####fi##########f###fi###################ifi Plant file name = C:\Program Files\U S Nuclear Regulatory Commission\Radtrad\OE.psf Inventory file name = c:\program files\u s nuclear regulatory commission\radtrad\defaults\fharb_def_a.nif Scenario file name = C:\Program Files\U S Nuclear Regulatory Commission\Radtrad\OE.psf Release file name = c:\program files\u s nuclear regulatory commission\radtrad\defaults\fha update 6-9-05.rft Dose conversion file name = c:\program files\u s nuclear regulatory commission\radtrad\defaults\fgrll&12.inp
- i## i#### #####f #f if if i#if # if # #fffii
- f # if if# # # # #f
- f #i # if if # # if if if # if # if #i #if f if if if
- i #i# i# # ffi#f ### if c:\program ifiesu sinuclear Radtrad 3.02 1/5/2000 TMI-1 FHAIC With Hatch Doors Opened, AST Analysis, CR Charcoal Filter Efficiency =
75%., CR Recirc = 28,000 cfm, CR Intake = 8,000 cfm Nuclide Inventory File:
c:\program files\u s nuclear regulatory commission\radtrad\defaults\fharb_def_a.nif Plant Power Level:
2.6190E+03 Compartments:
3 Compartment 1:
Containment 3
2.1600E+06 0
0 0
0 0
Compartment 2:
Environment 2
0.OOOOE+00 0
0 0
0 0
Compartment 3:
Control Room 1
2.5000E+05 0
0 1
0
I CALCULATION NOC-I 101-900-EOOO-083 - REV. No. 2 PAGE NO. 109 0
Pathways:
4 Pathway 1:
Containment to Environment 1
2 2
Pathway 2:
Control Room Air Intake 2
3 2
Pathway 3:
Control Room Unfiltered Inleakage 2
3 2
Pathway 4:
Control Room Exhaust to Environment 3
2 2
End of Plant Model File Scenario Description Name:
Plant Model Filename:
Source Term:
1 1 1.OOOOE+00 c:\program files\u s nuclear regulatory commission\radtrad\defaults\fgrll&12.inp c:\program files\u s nuclear regulatory commission\radtrad\defaults\fha update 6 05.rft 7.2000E+01 0
0.OOOOE+00 5.7000E-01 4.3000E-01 1.OOOOE+00 Overlying Pool:
0 0.OOOOE+00 0
0 0
0 Compartments:
3 Compartment 1:
0 1
0 0
0 0
0 0
0 Compartment 2:
0 1
0 0
0 0
0 0
0 Compartment 3:
1
I CALCULATION NOC-I 101-900-EOOO-083 l REV. No. 2 l PAGE NO. 110 1
0 0
0 0
1 2.8000E+04 3
7 .2000E+01 O.OOOOE+00 O.OOOOE+0O O.OOOOE+00 7.2500E+01 9.9000E+01 7.5000E+O1 7.5000E+01 7.9200E+02 9.9000E+01 7.5000E+01 7.5000E+O1 0
0 Pathways:
4 Pathway 1:
0 0
0 0
0 1
3 7 .2000E+01 1.6580E+05 O.OOOOE+00 O.OOOOE+O0 O.OOOOE+00 7.4000E+01 O.OOOOE+00 O.OOOOE+O0 O.OOOOE+00 O.OOOOE+O0 7.9200E+02 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 0
0 0
0 0
0 Pathway 2:
0 0
0 0
0 1
3 7 .2000E+01 4.OOOOE+03 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 7 .2500E+01 8.OOOOE+03 9.9000E+O1 7.5000E+O1 7.5000E+0l 7 .9200E+02 O.OOOOE+O0 O.OOOOE+00 O.OOOOE+0O O.OOOOE+00 0
0 0
0 0
0 Pathway 3:
0 0
0 0
0 1
2 7 .2000E+01 1.OOOOE+03 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 7.9200E+02 O.OOOOE+00 O.OOOOE+00 O.OOOOE+OO O.OOOOE+00 0
0 0
0 0
0 Pathway 4:
0 0
CALCULATION NOC-1 101-900-EOOO-083 1 REV. No. 2 I PAGENO. 111 0
0 0
1 3
7.2000E+Ol 5.0000E+03 0.0000E+00 O.OOOOE+00 O.OOOOE+0O 7.2500E+0l 9.OOOOE+03 1.0000E+02 1.OOOOE+02 1.OOOOE+02 7.9200E+02 O.OOOOE+00 2.OOOOE+00 O.OOOOE+00 O.OOOOE+00 0
0 0
0 0
0 Dose Locations:
3 Location 1:
Exclusion Area Boundary 2
1 2
7.2000E+0l 8.0000E-04 7.2000E+02 O.OOOOE+O0 1
2 7.2000E+Ol 3.5000E-04 7.2000E+02 O.OOOOE+OO 0
Location 2:
Low Population Zone 2
1 6
7.2000E+O1 1.4000E-04 7.4000E+0l 6.OOOOE-05 8.OOOOE+O1 3.9000E-05 9.6000E+01 1.6000E-05 1.6800E+02 4.OOOOE-06 7.9200E+02 O.OOOOE+00 1
4 7.2000E+01 3.5000E-04 8.OOOOE+01 1.8000E-04 9.6000E+O1 2.3000E-04 7.9200E+02 O.OOOOE+00 0
Location 3:
Control Room 3
0 1
2 7.2000E+O1 3.5000E-04 7.9200E+02 O.OOOOE+O0 1
4 7.2000E+01 1.OOOOE+00 9.6000E+01 6.OOOOE-01 1.6800E+02 4.OOOOE-O1 7.9200E+02 O.OOOOE+00 Effective Volume Location:
1 6
7.2000E+O1 5.34OOE-04 7.4000E+01 3.1000E-04 8.OOOOE+01 1.3600E-04 9.6000E+01 9.70OOE-05 1.6800E+02 6.0200E-05
I CALCULATION NOC-1 101-900-EOOO-083 l REV. No. 2 l PAGE NO. 112 7.9200E+02 O.OOOOE+00 Simulation Parameters:
6 7.2000E+01 1.OOOOE-O1 7.4000E+01 5.OOOOE-Ol 8.OOOOE+01 l.OOOOE+O0 9.6000E+01 2.OOOOE+00 1.6800E+02 4.OOOOE+00 7.9200E+02 O.OOOOE+O0 Output Filename:
C:\Program Files\U S Nuclear Regulatory Commission\Radtrad\OE.ol 1
1 0
0 End of Scenario File RADTRAD Version 3.02 run on 7/07/2005 at 7:53:39 Plant Description Number of Nuclides = 60 Inventory Power = 1.OOOOE+00 MWth Plant Power Level 2.6190E+03 MWth Number of compartments = 3 Compartment information Compartment number 1 (Source term fraction = 1.OOOOE+O0
)
Name: Containment Compartment volume = 2.1600E+06 (Cubic feet)
Pathways into and out of compartment 1 Pathway to compartment number 2: Containment to Environment Compartment number 2 Name: Environment Pathways into and out of compartment 2 Pathway to compartment number 3: Control Room Air Intake Pathway to compartment number 3: Control Room Unfiltered Inleakage Pathway from compartment number 1: Containment to Environment Pathway from compartment number 3: Control Room Exhaust to Environment Compartment number 3 Name: Control Room Compartment volume 2.5000E+05 (Cubic feet)
Removal devices within compartment:
FilterCs)
Pathways into and out of compartment 3 Pathway to compartment number 2: Control Room Exhaust to Environment Pathway from compartment number 2: Control Room Air Intake Pathway from compartment number 2: Control Room Unfiltered Inleakage Total number of pathways = 4 RADTRAD Version 3.02 run on 7/07/2005 at 7:53:39
CALCULATION NOC-1101-900-EOOO-083 TREV. No. 2 l PAGE NO. 113 l Scenario Description Time between shutdown and first release = 7.2000E+01 (Hours)
Radioactive Decay is enabled RELEASENAME = RG-1.183, Tables 3 Section 3.2 Release Fractions and Timings GAP EARLY IN-VESSEL 0.0036 hrs 0.0000 hrs NOBLES 1.OOOOE-01 0.OOOOE+00 IODINE 1.OOOOE-01 0.OOOOE+00 CESIUM 0.OOOOE+00 0.OOOOE+00 TELLURIUM 0.OOOOE+00 0.OOOOE+00 STRONTIUM 0.OOOOE+00 0.0000E+00 BARIUM 0.OOOOE+00 0.OOOOE+00 RUTHENIUM 0.OOOOE+00 0.OOOOE+00 CERIUM 0.OOOOE+00 0.OOOOE+00 LANTHANUM 0.OOOOE+00 0.OOOOE+00 Iodine fractions Aerosol = 0.OOOOE+00 Elemental = 5.7000E-01 Organic = 4.3000E-01 COMPARTMENT DATA Compartment number 1: Containment Compartment number 2: Environment Compartment number 3: Control Room Compartment Filter Data Time (hr) Flow Rate Filter Efficiencies (%)
(cfm) Aerosol Elemental Organic 7.2000E+01 2.8000E+04 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 7.2500E+01 2.8000E+04 9.9000E+01 7.5000E+01 7.5000E+01 7.9200E+02 2.8000E+04 9.9000E+01 7.5000E+01 7.5000E+01 PATHWAY DATA Pathway number 1: Containment to Environment Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)
(cfm) Aerosol Elemental Organic 7.2000E+01 1.6580E+05 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 7.4000E+01 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 7.9200E+02 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Pathway number 2: Control Room Air Intake Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)
(cfm) Aerosol Elemental Organic 7.2000E+01 4.OOOOE+03 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 7.2500E+01 8.0000E+03 9.9000E+01 7.5000E+01 7.5000E+01 7.9200E+02 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Pathway number 3: Control Room Unfiltered Inleakage Pathway Filter: Removal Data
I CALCULATION NOC-1101-900-EOOO-083 - REV. No. 2 1 PAGE NO. 114 Time (hr) Flow Rate Filter Efficiencies (%)
(cfm) Aerosol Elemental Organic 7.2000E+01 1.OOOOE+03 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 7.9200E+02 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 O.OOOOE+00 Pathway number 4: Control Room Exhaust to Environment Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)
(cfm) Aerosol Elemental Organic 7.2000E+01 5.OOOOE+03 0.0000E+00 0.OOOOE+00 0.OOOOE+00 7.2500E+01 9.OOOOE+03 1.OOOOE+02 1.0000E+02 1.OOOOE+02 7.9200E+02 0.OOOOE+00 2.OOOOE+00 0.OOOOE+00 0.OOOOE+00 LOCATION DATA Location Exclusion Area Boundary is in compartment 2 Location X/Q Data Time (hr) X/Q (s
- mA-3) 7.2000E+01 8.0000E-04 7.2000E+02 O.OOOOE+00 Location Breathing Rate Data Time (hr) Breathing Rate (mW3
- sec^-1) 7.2000E+01 3.5000E-04 7.2000E+02 0.OOOOE+00 Location Low Popul1ition Zone is in compartment 2 Location X/Q Data Time (hr) X/S' (s
- m^-3) 7.2000E+01 1.4000E-04 7.4000E+01 6.0000E-05 8.OOOOE+01 3.9000E-05 9.6000E+01 1.6000E-05 1.6800E+02 4.OOOOE-06 7.9200E+02 0.OOOOE+00 Location Breathing Rai:e Deita Time (hr) Breeathiing Rate (m^3
- sei 7.2000E+01 3.5000E-04 8.OOOOE+01 1.8000E-04 9.6000E+01 2.3000E-04 7.9200E+02 0.OOOOE+00 Location Control Room is in compartment 3 Location X/Q Data Time (hr) X/ Q (s
- mA-3) 7.2000E+01 5.3400E-04 7.4000E+01 3.1000E-04 8.OOOOE+01 1.3600E-04 9.6000E+01 9.7000E-05 1.6800E+02 6.0200E-05 7.9200E+02 O.OOOOE+00 Location Breathing Rat:e Data Time (hr) BrEeathing Rate (mA3
- sec^-1) 7.2000E+01 3.5000E-04 7.9200E+02 0.OOOOE+00 Location Occupancy Facctor Data Time (hr) Occcupancy Factor 7.2000E+01 1.OOOOE+00 9.6000E+01 6.OOOOE-01 1.6800E+02 4.OOOOE-01 7.9200E+02 0.OOOOE+00
CALCULATION NOC-1I 10-900-EOOO-083 REV.No. 2 PAGE NO.115 USER SPECIFIED TIME STEP DATA - SUPPLEMENTAL TIME STEPS Time Time step o.OOOOE+00 1.OOOOE-01 2.OOOOE+00 5.OOOOE-01 8.OOOOE+00 1.OOOOE+00 2.4000E+01 2.OOOOE+00 9.6000E+01 4.0000E+00 7.2000E+02 0.OOOOE+00 RADTRAD Version 3.02 run on 7/07/2005 at 7:53:39
- ####* H### # # #####
- *
- It It ft It ft It It It #
- ~ut ###f # #
- I#######*t#######*##########*f#######t#####~#################f###*#######
Dose, Detailed model and Detailed Inventory Output Exclusion Area Boundary Doses:
Time (h) = 72.0036 Whole Body Thyroid TEDE Delta dose (rem) 3.9946E-03 1.0846E+00 3.7073E-02 Accumulated dose (rem) 3.9946E-03 1.0846E+00 3.7073E-02 Low Population Zone Doses:
Time (h) = 72.0036 Whole Body Thyroid TEDE Delta dose (rem) 6.9906E-04 1.8981E-01 6.4878E-03 Accumulated dose (rem) 6.9906E-04 1.8981E-01 6.4878E-03 Control Room Doses:
Time (h) = 72.0036 Whole Body Thyroid TEDE Delta dose (rem) 2.5519E-07 1.2176E-03 3.7387E-05 Accumulated dose (rem) 2.5519E-07 1.2176E-03 3.7387E-05 Control Room Compartment Nuclide Inventory:
Time (h) = 72.0036 Ci kg Atoms Bq Kr-85 2.0817E-02 5.3058E-08 3.7591E+17 7.7022E+08 Kr-85m 3.3667E-06 4.0910E-16 2.8984E+09 1.2457E+05 Kr-88 1.5065E-08 1.2014E-18 8.2219E+06 5.5741E+02 I-131 4.3989E-03 3.5482E-11 1.6311E+14 1.6276E+08 I-133 6.7593E-04 5.9669E-13 2.7017E+12 2.5009E+07 I-135 3.6515E-06 1. 0398E-15 4.6383E+09 1.3511E+05 Xe-133 1.0054E+00 5.3711E-09 2.4320E+16 3.7199E+10 Xe-135 2.2653E-03 8.8705E-13 3.9570E+12 8.3816E+07 Control Room Transport Group Inventory:
Overlying Time (h) = 72.0036 Atmosphere Sump Pool Noble gases (atoms) 4.0024E+17 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 9.4518E+13 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) 7.1303E+13 0. OOOOE+00 0.0000E+00 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00
CALCULATION NOC-1 101-900-EOOO-083 § REV. No. 2 I PAGE NO. 116 Deposition Recirculating Time (h) = 72.0036 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) O.OOOOE+00 0.OOOOE+00 Organic I (atoms) O.OOOOE+00 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 72.0036 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 72.0036 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 72.0036 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.0000E+00 Exclusion Area Boundary Doses:
Time (h) = 72.5000 Whole Body Thyroid TEDE Delta dose (rem) 4.3151E-01 1.1720E+02 4.0058E+00 Accumulated dose (rem) 4.3551E-01 1.1829E+02 4.0429E+00 Low Population Zone Doses:
Time (h) = 72.5000 Whole Body Thyroid TEDE Delta dose (rem) 7.5515E-02 2.0510E+01 7. 01OE-01 Accumulated dose (rem) 7.6214E-02 2.0700E+01 7.0750E-01 Control Room Doses:
Time (h) = 72.5000 Whole Body Thyroid TEDE Delta dose (rem) 5.2760E-03 2.5188E+01 7.7343E-01 Accumulated dose (rem) 5.2763E-03 2.5190E+01 7.7347E-01 Control Room Compartment Nuclide Inventory:
Time (h) 72.5000 Ci kg Atoms Bq Kr-85 1.5368E+00 3.9169E-06 2.7751E+19 5.6860E+10 Kr-85m 2.3017E-04 2.7968E-14 1.9815E+11 8.5162E+06 Kr-88 9.8526E-07 7.8574E-17 5.3771E+08 3.6455E+04 I-131 3.2416E-01 2.6147E-09 1.2020E+16 1.1994E+10 I-133 4.9081E-02 4.3327E-11 1.9618E+14 1. 8160E+09 I-135 2.5589E-04 7.2866E-14 3.2504E+11 9.4681E+06 Xe-133 7.4017E+01 3.9543E-07 1.7905E+18 2.7386E+12 Xe- 135 1.6102E-01 6.3053E-11 2.8127E+14 5.9577E+09 Control Room Transport Group Inventory:
Overlying
ICALCULATION NOC-I101-900-EOOO-083 T REV. No. 2 l PAGENO.117 Time (h) = 72.5000 Atmosphere Sump Pool Noble gases (atoms) 2.9547E+19 o.OOOOE+00 0.0000E+00 Elemental I (atoms) 6.9776E+15 0.OOOOE+00 0.0000E+00 Organic I (atoms) 5.2638E+15 0.0000E+00 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Deposition Recirculating Time (h) = 72.5000 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 72.5000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 72.5000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 72.5000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.0000E+00 Exclusion Area Boundary Doses:
Time (h) = 74.0000 Whole Body Thyroid TEDE Delta dose (rem) 4.9006E-02 1.3212E+01 4.5191E-01 Accumulated dose (rem) 4.8451E-01 1.3150E+02 4.4948E+00 Low Population Zone Doses:
Time (h) = 74.0000 Whole Body Thyroid TEDE Delta dose (rem) 8.5760E-03 2.3121E+00 7.9084E-02 Accumulated dose (rem) 8.4790E-02 2.3012E+01 7. 8659E-01 Control Room Doses:
Time (h) = 74.0000 Whole Body Thyroid TEDE Delta dose (rem) 7.3401E-03 1.0108E+01 3.1559E-01 Accumulated dose (rem) 1.2616E-02 3.5298E+01 1.0891E+00 Control Room Compartment Nuclide Inventory:
Time (h) = 74.0000 Ci kg Atoms Bq Kr-85 9.3790E-02 2.3906E-07 1. 6937E+18 3.4702E+09 Kr-85m 1.1138E-05 1.3534E-15 9.5889E+09 4.1211E+05 Kr-88 4.1698E-08 3.3254E-18 2.2757E+07 1.5428E+03 I-131 6.2347E-05 5.0290E-13 2.3119E+12 2.3068E+06 I-133 9.0281E-06 7.9697E-15 3.6086E+10 3.3404E+05 I-135 4.2281E-08 1.2039E-17 5.3706E+07 1.5644E+03 Xe-133 4.4803E+00 2.3935E-08 1.0838E+17 1.6577E+11
I CALCULATION NOC-1 10 I-90E000-083 I REV. No. 2 I PAGE NO. 118 _
Xe-135 8.7652E-03 3.4323E-12 1.5311E+13 3.2431E+08 Control Room Transport Group Inventory:
Overlying Time (h) = 74.0000 Atmosphere Sump Pool Noble gases (atoms) 1.8033E+18 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 1.3493E+12 0.OOOOE+00 0.0000E+00 Organic I (atoms) 1.0179E+12 0.OOOOE+00 0.0000E+00 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 0.0000E+00 Deposition Recirculating Time (h) = 74.0000 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 5.3450E+15 Organic I (atoms) 0.OOOOE+00 4.0322E+15 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 74.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 5.0636E+20 Organic I (atoms) 3.8199E+20 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 74.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 74.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 2.2907E+15 Organic I (atoms) 1.7281E+15 Aerosols (kg) 0.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 80.0000 Whole Body Thyroid TEDE Delta dose (rem) 2.1001E-05 0.OOOOE+00 2.1001E-05 Accumulated dose (rem) 4.8453E-01 1.3150E+02 4.4948E+00 Low Population Zone Doses:
Time (h) = 80.0000 Whole Body Thyroid TEDE Delta dose (rem) 1.5751E-06 0.OOOOE+00 1.5751E-06 Accumulated dose (rem) 8.4791E-02 2.3012E+01 7.8659E-01 Control Room Doses:
Time (h) = 80.0000 Whole Body Thyroid TEDE Delta dose (rem) 3.5311E-04 1.7776E-03 4.0731E-04 Accumulated dose (rem) 1.2969E-02 3 .5299E+01 1.0895E+00 Control Room Compartment Nuclide Inventory:
Time (h) = 80.0000 Ci kg Atoms Bq Kr-85 2.2444E-07 5.7205E-13 4.0529E+12 8.3041E+03 Xe-133 1.0373E-05 5.5417E-14 2.5093E+11 3. 8381E+05
CALCULATION NOC-1 101-900-EOOO-083 I REV. No. 2 l PAGE NO. 119 Xe-135 1.3274E-08 5.1981E-18 2.3188E+07 4.9116E+02 Control Room Transport Group Inventory:
Overlying Time (h) = 80.0000 Atmosphere Sump Pool Noble gases (atoms) 4.3154E+12 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 2.3366E-07 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) 1.7627E-07 0.OOOOE+00 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Deposition Recirculating Time (h) = 80.0000 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 5.3459E+15 Organic I (atoms) 0.0000E+00 4.0329E+15 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 80.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 5.0636E+20 Organic I (atoms) 3.8199E+20 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 80.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 80.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 2.2911E+15 Organic I (atoms) 1.7284E+15 Aerosols (kg) 0.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 96.0000 Whole Body Thyroid TEDE Delta dose (rem) 4.8350E-11 0.0000E+00 4.8350E-11 Accumulated dose (rem) 4.8453E-01 1.3150E+02 4.4948E+00 Low Population Zone Doses:
Time (h) = 96.0000 Whole Body Thyroid TEDE Delta dose (rem) 2.3571E-12 0.OOOOE+00 2.3571E-12 Accumulated dose (rem) 8.4791E-02 2.3012E+01 7.8659E-01 Control Room Doses:
Time (h) = 96.0000 Whole Body Thyroid TEDE Delta dose (rem) 8.1291E-10 3.OO11E-22 8.1291E-10 Accumulated dose (rem) 1.2969E-02 3.5299E+01 1.0895E+00 Control Room Compartment Nuclide Inventory:
Time (h) = 96.0000 Ci kg Atoms Bq Control Room Transport Group Inventory:
I CALCULATION NOC-1101-900-E000-083 I REV. No. 2 - PAGE NO. 120 l Overlying Time (h) = 96.0000 Atmosphere Sump Pool Noble gases (atoms) 4.3099E-03 0.0000E+00 0.OOOOE+00 Elemental I (atoms) 2.1724E-57 O.0000E+00 O.0000E+00 Organic I (atoms) 1.6388E-57 0.OOOOE+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.OOOOE+00 0.OOOOE+00 Deposition Recirculating Time (h) = 96.0000 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 0.0000E+00 Elemental I (atoms) 0.OOOOE+00 5.3459E+15 Organic I (atoms) 0.OOOOE+00 4.0329E+15 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 5.0636E+20 Organic I (atoms) 3.8199E+20 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 2.2911E+15 Organic I (atoms) 1.7284E+15 Aerosols (kg) 0.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 168.0000 Whole Body Thyroid TEDE Delta dose (rem) 4.4032E-26 0.OOOOE+00 4.4032E-26 Accumulated dose (rem) 4.8453E-01 1.3150E+02 4.4948E+00 Low Population Zone Doses:
Time (h) = 168.0000 Whole Body Thyroid TEDE Delta dose (rem) 8.8064E-28 0.OOOOE+00 8.8064E-28 Accumulated dose (rem) 8.4791E-02 2.3012E+01 7.8659E-01 Control Room Doses:
Time (h) = 168.0000 Whole Body Thyroid TEDE Delta dose (rem) 9.8113E-25 1.0836E-71 9.8113E-25 Accumulated dose (rem) 1.2969E-02 3.5299E+01 1.0895E+00 Control Room Compartment Nuclide Inventory:
Time (h) = 168.0000 Ci kg Atoms Bq Control Room Transport Group Inventory:
Overlying Time (h) = 168.0000 Atmosphere Sump Pool
CALCULATION NOC-I 101-900-EOOO-083 I REV. No. 2 1 PAGE NO. 121 Noble gases (atoms) 1.3206E-70 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 1.5585-282 O.OOOOE+00 0.OOOOE+00 Organic I (atoms) 1.1757-282 0.OOOOE+00 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Deposition Recirculating Time (h) = 168.0000 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 5.3459E+15 Organic I (atoms) 0.0000E+00 4.0329E+15 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 168.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 5.0636E+20 Organic I (atoms) 3.8199E+20 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 168.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 168.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 2.2911E+15 Organic I (atoms) 1.7284E+15 Aerosols (kg) 0.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 720.0000 Whole Body Thyroid TEDE Delta dose (rem) 9.0557E-94 0.OOOOE+00 9.0557E-94 Accumulated dose (rem) 4.8453E-01 1.3150E+02 4.4948E+00 Low Population Zone Doses:
Time (h) = 720.0000 Whole Body Thyroid TEDE Delta dose (rem) 4.5279E-96 0.OOOOE+00 4.5279E-96 Accumulated dose (rem) 8.4791E-02 2.3012E+01 7.8659E-01 Control Room Doses:
Time (h) = 720.0000 Whole Body Thyroid TEDE Delta dose (rem) 2.6210E-92 7.9155-297 2.6210E-92 Accumulated dose (rem) 1.2969E-02 3.5299E+01 1.0895E+00 Control Room Compartment Nuclide Inventory:
Time (h) = 720.0000 Ci kg Atoms Bq Control Room Transport Group Inventory:
Overlying Time (h) = 720.0000 Atmosphere Sump Pool Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00
CALCULATION NOC-I 101-900-EOOO-083 -TREV. No. 2 l PAGE NO. 122 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 0.0000E+00 Deposition Recirculating Time (h) = 720.0000 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 5.3459E+15 Organic I (atoms) 0.OOOOE+00 4.0329E+15 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 5.0636E+20 Organic I (atoms) 3.8199E+20 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 2.2911E+15 Organic I (atoms) 1.7284E+15 Aerosols (kg) 0.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 792.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Accumulated dose (rem) 4.8453E-01 1.3150E+02 4.4948E+00 Low Population Zone Doses:
Time (h) = 792.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Accumulated dose (rem) 8.4791E-02 2.3012E+01 7.8659E-01 Control Room Doses:
Time (h) = 792.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Accumulated dose (rem) 1.2969E-02 3.5299E+01 1.0895E+00 Control Room Compartment Nuclide Inventory:
Time (h) = 792.0000 Ci kg Atoms Bq Control Room Transport Group Inventory:
Overlying Time (h) = 792.0000 Atmosphere Sump Pool Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Deposition Recirculating
I CALCULATION NOC-110I-900-E000-083 I REV. No. 2 l PAGE NO. 123 Time (h) = 792.0000 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.0000E+00 5.3459E+15 Organic I (atoms) 0.OOOOE+00 4.0329E+15 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 792.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 5.0636E+20 Organic I (atoms) 3.8199E+20 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 792.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 792.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 2.2911E+15 Organic I (atoms) 1.7284E+15 Aerosols (kg) 0.OOOOE+00 334 I-131 Summary Containment Environment Control Room Time (hr) I-131 (Curies) 1-131 (Curies) 1-131 (Curies) 72.001 6.5355E+01 8.3646E-02 1.0538E-04 72.004 4.2054E+02 3.4959E+00 4.3989E-03 72.400 6.7659E+01 3.5615E+02 3.3229E-01 72.500 4.2673E+01 3.8115E+02 3.2416E-01 72.800 1.0706E+01 4.1309E+02 4.5115E-02 73.100 2.6861E+00 4.2110E+02 7.1470E-03 73.400 6.7390E-01 4.2311E+02 1.3125E-03 73.700 1.6907E-01 4.2362E+02 2.7393E-04 74.000 4.2419E-02 4.2374E+02 6.2347E-05 74.300 4.2373E-02 4.2374E+02 7.1824E-06
- 74. 600 4.2328E-02 4.2374E+02 8.2742E-07 74.900 4.2282E-02 4.2374E+02 9.5319E-08 75.200 4.2236E-02 4.2374E+02 1.0981E-08 75.500 4.2191E-02 4.2374E+02 1.2650E-09 75.800 4.2146E-02 4.2374E+02 1.4573E-10 76.100 4.2100E-02 4.2374E+02 1.6788E-11 76.400 4.2055E-02 4.2374E+02 1.9340E-12 76.700 4.2010E-02 4.2374E+02 2.2280E-13 77.000 4.1964E-02 4.2374E+02 2.5667E-14 77.300 4.1919E-02 4.2374E+02 2.9568E-15 77.600 4.1874E-02 4.2374E+02 3.4063E-16 77.900 4.1829E-02 4.2374E+02 3.9241E-17 78.200 4.1784E-02 4.2374E+02 4.5206E-18 78.500 4.1739E-02 4.2374E+02 5.2078E-19 78.800 4.1694E-02 4.2374E+02 5.9994E-20 79.100 4.1649E-02 4.2374E+02 6.9114E-21 79.400 4.1604E-02 4.2374E+02 7.9620E-22
CALCULATION NOC-I 101-900-E000-083 - REV. No. 2 T PAGE NO. 124 79.700 4.1559E-02 4.2374E+02 9.1722E-23
- 80. 000 4.1514E-02 4.2374E+02 1.0567E-23 80.300 4.1470E-02 4.2374E+02 1.2173E-24
- 80. 600 4.1425E-02 4.2374E+02 1.4023E-25 80.900 4.1380E-02 4.2374E+02 1.6155E-26 81.200 4.1336E-02 4.2374E+02 1.8610E-27 81.500 4.1291E-02 4.2374E+02 2.1439E-28 81.800 4.1247E-02 4.2374E+02 2.4698E-29 82.100 4.1202E-02 4.2374E+02 2.8453E-30 82.400 4.1158E-02 4.2374E+02 3.2778E-31 96.000 3.9196E-02 4.2374E+02 9.2753E-74 168.000 3.0263E-02 4.2374E+02 5.1378-299 720.000 4.1664E-03 4.2374E+02 O.OOOOE+00 792.000 3 .2169E-03 4.2374E+02 O.OOOOE+00 Cumulative Dose Summary Exclusion Area Bounda Low Population Zone Contro]l Room Time Thyroid TEDE Thyroid TEDE Thyroid TEDE (hr) (rem) (rem) (rem) (rem) (rem) (rem) 72.001 2.5952E-02 8.8702E-04 4.5415E-03 1.5523E-04 5.7730E-06 1.7727E-07 72.004 1.0846E+00 3.7073E-02 1.8981E-01 6.4878E-03 1.2176E-03 3.7387E-05 72.400 1.1053E+02 3.7778E+00 1.9343E+01 6.6111E-01 1.8717E+01 5.7473E-01 72.500 1.1829E+02 4.0429E+00 2.0700E+01 7.0750E-01 2.5190E+01 7.7347E-01 72.800 1.2819E+02 4.3816E+00 2.2434E+01 7.6679E-01 3.3797E+01 1.0393E+00 73.100 1.3068E+02 4.4667E+00 2.2869E+01 7.8167E-01 3.5042E+01 1.0792E+00 73.400 1.313OE+02 4.4880E+00 2.2978E+01 7.8541E-01 3.5249E+01 1.0867E+00 73.700 1.3146E+02 4.4934E+00 2.3005E+01 7.8635E-01 3.5289E+01 1.0885E+00 74.000 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5298E+01 1.0891E+00 74.300 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5299E+01 1.0893E+00 74.600 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5299E+01 1.0894E+00 74.900 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5299E+01 1.0894E+00 75.200 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5299E+01 1.0894E+00 75.500 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5299E+01 1.0895E+00 75.800 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5299E+01 1.0895E+00 76.100 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5299E+01 1.0895E+00 76.400 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5299E+01 1.0895E+00 76.700 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5299E+01 1.0895E+00 77.000 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5299E+01 1.0895E+00 77.300 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5299E+01 1.0895E+00 77.600 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5299E+01 1.0895E+00 77.900 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5299E+01 1.0895E+00 78.200 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5299E+01 1.0895E+00 78.500 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5299E+01 1.0895E+00
- 78. 800 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5299E+01 1.0895E+00 79.100 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5299E+01 1.0895E+00 79.400 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5299E+01 1.0895E+00 79.700 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5299E+01 1.0895E+00 80.000 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5299E+01 1.0895E+00 80.300 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5299E+01 1.0895E+00
- 80. 600 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5299E+01 1.0895E+00
- 80. 900 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5299E+01 1.0895E+00 81.200 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5299E+01 1.0895E+00 81.500 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5299E+01 1.0895E+00 81.800 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5299E+01 1.0895E+00 82.100 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5299E+01 1.0895E+00 82.400 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5299E+01 1.0895E+00 96.000 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5299E+01 1.0895E+00 168.000 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5299E+01 1.0895E+00 720. 000 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5299E+01 1.0895E+00 792.000 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.5299E+01 1.0895E+00 Worst Two-Hour Doses Note: All of the dose locations are shown below but the worst two-hour dose is only meaningful for the EAB
CALCULATION NOC-I 10 I-900-EOOO-083 I REV. No. 2 l PAGE NO. 125 dose location. Please disregard the two-hour worst doses for the other dose locations Exclusion Area Boundary Time Whole Body Thyroid TEDE (hr) (rem) (rem) (rem) 72.0 4.8442E-01 1.3147E+02 4.4939E+00 Low Population Zone Time Whole Body Thyroid TEDE (hr) (rem) (rem) (rem) 72.0 8.4773E-02 2.3008E+01 7.8643E-01 Control Room Time Whole Body Thyroid TEDE (hr) (rem) (rem) (rem) 72.0 1.2616E-02 3.5298E+01 1.0891E+00
CALCULATION NOC-1 101-900-EOOO-083 REV. No. 2 PAGE NO. 126 l Appendix H RADTRAD File OF.psf FHA Occurring In Reactor Building With Hatch Doors Opened CR Recirc Flow: 28,000 cfm CR Filtered Intake Flow: 7,200 cfm CR Unfiltered Inleakage: 1,000 cfm CR Exhaust Flow: 8,200 cfm Two Times Iodine & Noble Gas Release Fractions
I CALCULATION NOC-I 101-900-EOOO-083 - REV. No. 2 @PAGE NO. 127
- fi#####fi##i##f##f#####i##f###############f###i##i###i##i##f###i##f####fi###############f RADTRAD Version 3.02 run on 7/07/2005 at 7:53:39 File information
- fii##i########iifi#########ifi##f##f#########fi######ii### i#########f##i#######i#if#########
Plant file name = C:\Program Files\U S Nuclear Regulatory Commission\Radtrad\0F.psf Inventory file name = c:\program files\u s nuclear regulatory commission\radtrad\defaults\fharb_def_a.nif Scenario file name = C:\Program Files\U S Nuclear Regulatory Commission\Radtrad\OF.psf Release file name = c:\program files\u s nuclear regulatory commission\radtrad\defaults\fha update 6-9-05.rft Dose conversion file name = c:\program files\u s nuclear regulatory commission\radtrad\defaults\fgrll&12.inp
- ifi ### #### -fffii
- if if ###### if if ififififif
- f #f # # # ##i # #f # if if #
- f # # if # #fi# # if # if if #
i##### ####fi ####fi # # if # #ffi### if if #
- f #i #i#i# #i #i# if if if
- f # if if # ## if if if if
- f ####fi # # if #f #
Radtrad 3.02 1/5/2000 TMI-1 FHAIC With Hatch Doors Opened, AST Analysis, CR Charcoal Filter Efficiency =
75%., CR Recirc = 28,000 cfm, CR Intake = 7,200 cfm Nuclide Inventory File:
c:\program files\u s nuclear regulatory commission\radtrad\defaults\fharb_def_a.nif Plant Power Level:
2.6190E+03 Compartments:
3 Compartment 1:
Containment 3
2.1600E+06 0
0 0
0 0
Compartment 2:
Environment 2
O.OOOOE+00 0
0 0
0 0
Compartment 3:
Control Room 1
2.5000E+05 0
0 1
0
CALCULATION NOC-1 101-900-EOOO-083 - REV. No. 2 1 PAGE NO. 128 0
Pathways:
4 Pathway 1:
Containment to Environment 1
2 2
Pathway 2:
Control Room Air Intake 2
3 2
Pathway 3:
Control Room Unfiltered Inleakage 2
3 2
Pathway 4:
Control Room Exhaust to Environment 3
2 2
End of Plant Model File Scenario Description Name:
Plant Model Filename:
Source Term:
1 1 1.OOOOE+00 c:\program files\u s nuclear regulatory commission\radtrad\defaults\fgrll&12.inp c:\program files\u s nuclear regulatory commission\radtrad\defaults\fha update 6 05.rft 7.2000E+01 0
0.OOOOE+00 5.7000E-01 4.3000E-01 1.OOOOE+00 Overlying Pool:
0 0.OOOOE+00 0
0 0
0 Compartments:
3 Compartment 1:
0 1
0 0
0 0
0 0
0 Compartment 2:
0 1
0 0
0 0
0 0
0 Compartment 3:
1
ICALCULATION NOC-I 101-900-EOOO-083 I REV. No. 2 I PAGE NO. 129 1
0 0
0 0
1 2.8000E+04 3
7.2000E+01 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 7.2500E+O1 9.9000E+01 7.5000E+01 7.5000E+01 7.9200E+02 9.9000E+01 7.5000E+01 7.5000E+01 0
0 Pathways:
4 Pathway 1:
0 0
0 0
0 1
3 7.2000E+01 1.6580E+05 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 7.4000E+01 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 7.9200E+02 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 0
0 0
0 0
0 Pathway 2:
0 0
0 0
0 1
3 7.2000E+01 4.OOOOE+03 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 7.2500E+01 7.2000E+03 9.9000E+01 7.5000E+01 7.5000E+01 7.9200E+02 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 0
0 0
0 0
0 Pathway 3:
0 0
0 0
0 1
2 7.2000E+01 1.OOOOE+03 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 7.9200E+02 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 0
0 0
0 0
0 Pathway 4:
0 0
I CALCULATION NOC-I 101-900-EOOO-083 I REV. No. 2 I PAGE NO. 130 1 0
0 0
1 3
7.2000E+01 5.OOOOE+03 O.OOOOE+00 0.0000E+00 0.OOOOE+00 7.2500E+01 8.2000E+03 1.OOOOE+02 1.0000E+02 1.OOOOE+02 7.9200E+02 0.0000E+O0 O.OOOOE+OO 0.OOOOE+00 0.OOOOE+00 0
0 0
0 0
0 Dose Locations:
3 Location 1:
Exclusion Area Boundary 2
1 2
7.2000E+01 8.OOOOE-04 7.2000E+02 O.OOOOE+0O 1
2 7.2000E+01 3.5000E-04 7.2000E+02 O.OOOOE+00 0
Location 2:
Low Population Zone 2
1 6
7.2000E+01 1.4000E-04 7.4000E+01 6.OOOOE-05 8.OOOOE+01 3.9000E-05 9.6000E+01 1.6000E-05 1.6800E+02 4.OOOOE-06 7.9200E+02 O.OOOOE+00 1
4 7.2000E+01 3.5000E-04
- 8. OOOOE+01 1.8000E-04
- 9. 6000E+01 2.3000E-04 7.9200E+02 O.OOOOE+00 0
Location 3:
Control Room 3
0 1
2 7.2000E+01 3.500OE-04 7.9200E+02 O.OOOOE+O0 1
4 7.2000E+01 1.OOOOE+00 9.6000E+01 6.OOOOE-01 1.6800E+02 4.OOOOE-01 7.9200E+02 O.OOOOE+00 Effective Volume Location:
1 6
7.2000E+01 5.3400E-04 7.4000E+01 3.1000E-04
- 8. OOOOE+01 1.3600E-04
- 9. 6000E+01 9.7000E-05 1.6800E+02 6.0200E-05
I CALCULATION NOC-1 101-900-EOOO-083 I REV. No. 2 T PAGE NO. 131 l 7.9200E+02 O.OOOOE+00 Simulation Parameters:
6 7.2000E+01 1.OOOOE-0l 7.4000E+01 5.OOOOE-0l 8.0000E+01 1.OOOOE+O0 9.6000E+01 2.OOOOE+OO 1.6800E+02 4.OOOOE+00 7.9200E+02 O.OOOOE+00 Output Filename:
C:\Program Files\U S Nuclear Regulatory Commission\Radtrad\OF.o2 1
1 1
0 0
End of Scenario File RADTRAD Version 3.02 run on 7/07/2005 at 7:53:39 Plant Description Number of Nuclides = 60 Inventory Power = 1.OOOOE+00 MWth Plant Power Level = 2.6190E+03 MWth Number of compartments = 3 Compartment information Compartment number 1 (Source term fraction = 1.OOOOE+O0
)
Name: Containment Compartment volume = 2.1600E+06 (Cubic feet)
Pathways into and out of compartment 1 Pathway to compartment number 2: Containment to Environment Compartment number 2 Name: Environment Pathways into and out of compartment 2 Pathway to compartment number 3: Control Room Air Intake Pathway to compartment number 3: Control Room Unfiltered Inleakage Pathway from compartment number 1: Containment to Environment Pathway from compartment number 3: Control Room Exhaust to Environment Compartment number 3 Name: Control Room Compartment volume = 2.5000E+05 (Cubic feet)
Removal devices within compartment:
Filter(s)
Pathways into and out of compartment 3 Pathway to compartment number 2: Control Room Exhaust to Environment Pathway from compartment number 2: Control Room Air Intake Pathway from compartment number 2: Control Room Unfiltered Inleakage Total number of pathways = 4 RADTRAD Version 3.02 run on 7/07/2005 at 7:53:39
I CALCULATION NOC-1101-900-EOOO-083 _ REV. No. 2 l PAGE NO. 132 l Scenario Description Time between shutdown and first release = 7.2000E+01 (Hours)
Radioactive Decay is enabled RELEASE_NAME = RG-1.183, Tables 3 Section 3.2 Release Fractions and Timings GAP EARLY IN-VESSEL 0.0036 hrs 0.0000 hrs NOBLES 1.0000E-01 0.0000E+00 IODINE 1.OOOOE-01 0.0000E+00 CESIUM 0.0000E+00 0.0000E+00 TELLURIUM 0.0000E+00 0.0000E+00 STRONTIUM 0.0000E+00 0.0000E+00 BARIUM 0.0000E+00 0.0000E+00 RUTHENIUM 0.0000E+00 0.OOOOE+00 CERIUM 0.OOOOE+00 0.OOOOE+00 LANTHANUM 0.0000E+00 0.0000E+00 Iodine fractions Aerosol 0.OOOOE+00 Elemental 5.7000E-01 Organic 4.3000E-01 COMPARTMENT DATA Compartment number 1: Containment Compartment number 2: Environment Compartment number 3: Control Room Compartment Filter Data Time (hr) Flow Rate Filter Efficiencies (%)
(cfm) Aerosol Elemental Organic 7.2000E+01 2.8000E+04 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 7.2500E+01 2.8000E+04 9.9000E+01 7.5000E+01 7.5000E+01 7.9200E+02 2.8000E+04 9.9000E+01 7.5000E+01 7.5000E+01 PATHWAY DATA Pathway number 1: Containment to Environment Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)
(cfm) Aerosol Elemental Organic 7.2000E+01 1.6580E+05 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 7.4000E+01 0.OOOOE+00 0.0000E+00 0.0000E+00 0.OOOOE+00 7.9200E+02 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Pathway number 2: Control Room Air Intake Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)
(cfm) Aerosol Elemental Organic 7.2000E+01 4.OOOOE+03 0.0000E+00 0.OOOOE+00 0.OOOOE+00 7.2500E+01 7.2000E+03 9.9000E+01 7.5000E+01 7.5000E+01 7.9200E+02 0.OOOOE+00 0.OOOOE+00 0.0000E+00 0.0000E+00 Pathway number 3: Control Room Unfiltered Inleakage Pathway Filter: Removal Data
I CALCULATION NOC-I 10I-900-EOOO-083 I REV. No. 2 T PAGE NO. 133 Time (hr) Flow Rate Filter Efficiencies (%)
(cfm) Aerosol Elemental Organic 7.2000E+01 1.0000E+03 0.0000E+00 0.0000E+00 0.0000E+00 7.9200E+02 0.00O0E+00 O.OOOOE+00 O.OOOOE+00 0.OOOOE+00 Pathway number 4: Control Room Exhaust to Environment Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)
(cfm) Aerosol Elemental Organic 7.2000E+01 5.OOOOE+03 0.OOOOE+00 O.OOOOE+00 0.OOOOE+00 7.2500E+01 8.2000E+03 1.0000E+02 1.0000E+02 1.0000E+02 7.9200E+02 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 LOCATION DATA Location Exclusion Area Boundary is in compartment 2 Location X/Q Data Time (hr) X/Q (S
- MnA 3) 7.2000E+01 8.OOOOE-04 7.2000E+02 O.OOOOE+00 Location Breathing Ra te Data Time (hr) Br eathing Rate (m^3
- secA-1) 7.2000E+01 3.5000E-04 7.2000E+02 0.OOOOE+00 Location Low Populatiion Zone is in compartment 2 Location X/Q Data Time (hr) X/I Ds* mA'-3) 7.2000E+01 1.4000E-04 7.4000E+01 6.OOOOE-05 8.OOOOE+01 3 .9000E-05 9.6000E+01 1.6000E-05 1.6800E+02 4.OOOOE-06 7.9200E+02 O.OOOOE+00 Location Breathing Rai te DM ita Time (hr) Br4eathiLng Rate (mA3
- se,cA-1) 7.2000E+01 3.5000E-04 8.0000E+01 1.8000E-04 9.6000E+01 2.3000E-04 7.9200E+02 0.OOOOE+00 Location Control Room is in compartment 3 Location X/Q Data Time (hr) X/ 2 (s
- mA-3) 7.2000E+01 5.3400E-04 7.4000E+01 3.1000E-04 8.OOOOE+01 1.3600E-04 9.6000E+01 9.7000E-05 1.6800E+02 6.0200E-05 7.9200E+02 0.OOOOE+00 Location Breathing Rat:e Data Time (hr) Br(eathing Rate (m^3
- sec^-1) 7.2000E+01 3.5000E-04 7.9200E+02 O.OOOOE+00 Location Occupancy Facctor Data Time (hr) Occcupancy Factor 7.2000E+01 1.OOOOE+00 9.6000E+01 6.OOOOE-01 1.6800E+02 4.OOOOE-01 7.9200E+02 0.0000E+00
CALCULATION NOC-1 101-900-EOOO-083 I REV. No. 2 1 PAGE NO. 134 USER SPECIFIED TIME STEP DATA - SUPPLEMENTAL TIME STEPS Time Time step 0.OOOOE+00 1.0000E-01 2.OOOOE+00 5.0000E-01 8.OOOOE+00 1.0000E+00 2.4000E+01 2.0000E+00 9.6000E+01 4.OOOOE+00 7.2000E+02 0.OOOOE+00 RADTRAD Version 3.02 run on 7/07/2005 at 7:53:39
- t # # it#it#it it#it#lt it it ##it##
- i# # it it itit it #
- # it lit # #
it it it it it
- t itit it # it itit #f it it it
- t Dose, Detailed model and Detailed Inventory Output Exclusion Area Boundary Doses:
Time (h) = 72.0036 Whole Body Thyroid TEDE Delta dose (rem) 3.9946E-03 1.0846E+00 3.7073E-02 Accumulated dose (rem) 3.9946E-03 1.0846E+00 3.7073E-02 Low Population Zone Doses:
Time (h) = 72.0036 Whole Body Thyroid TEDE Delta dose (rem) 6.9906E-04 1.8981E-01 6.4878E-03 Accumulated dose (rem) 6.9906E-04 1.8981E-01 6.4878E-03 Control Room Doses:
Time (h) = 72.0036 Whole Body Thyroid TEDE Delta dose (rem) 2.5519E-07 1.2176E-03 3.7387E-05 Accumulated dose (rem) 2.5519E-07 1.2176E-03 3.7387E-05 Control Room Compartment Nuclide Inventory:
Time (h) = 72.0036 Ci kg Atoms Bq Kr-85 2.0817E-02 5.3058E-08 3.7591E+17 7.7022E+08 Kr-85m 3.3667E-06 4.0910E-16 2.8984E+09 1.2457E+05 Kr-88 1.5065E-08 1.2014E-18 8.2219E+06 5.5741E+02 I-131 4.3989E-03 3.5482E-11 1.6311E+14 1.6276E+08 I-133 6.7593E-04 5.9669E-13 2.7017E+12 2.5009E+07 I-135 3.6515E-06 1.0398E-15 4.6383E+09 1.3511E+05 Xe-133 1.0054E+00 5.3711E-09 2.4320E+16 3.7199E+10 Xe-135 2.2653E-03 8.8705E-13 3.9570E+12 8.3816E+07 Control Room Transport Group Inventory:
Overlying Time (h) = 72.0036 Atmosphere Sump Pool Noble gases (atoms) 4.0024E+17 0.0000E+00 0.0000E+00 Elemental I (atoms) 9.4518E+13 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) 7.1303E+13 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00
CALCULATION NOC-I 10I-900-EOOO-083 REV. No. 2 PAGE NO. 135 Deposition Recirculating Time (h) = 72.0036 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.0000E+00 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 72.0036 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 72.0036 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 72.0036 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 72.5000 Whole Body Thyroid TEDE Delta dose (rem) 4.3151E-01 1.1720E+02 4.0058E+00 Accumulated dose (rem) 4.3551E-01 1.1829E+02 4.0429E+00 Low Population Zone Doses:
Time (h) = 72.5000 Whole Body Thyroid TEDE Delta dose (rem) 7.5515E-02 2.0510E+01 7.0101E-01 Accumulated dose (rem) 7.6214E-02 2. 0700E+01 7.0750E-01 Control Room Doses:
Time (h) = 72.5000 Whole Body Thyroid TEDE Delta dose (rem) 5.2760E-03 2.5188E+01 7.7343E-01 Accumulated dose (rem) 5.2763E-03 2.5190E+01 7.7347E-01 Control Room Compartment Nuclide Inventory:
Time (h) = 72.5000 Ci kg Atoms Bq Kr-85 1.5368E+00 3.9169E-06 2.7751E+19 5.6860E+10 Kr-85m 2.3017E-04 2.7968E-14 1.9815E+11 8.5162E+06 Kr-88 9.8526E-07 7.8574E-17 5.3771E+08 3.6455E+04 1-131 3.2416E-01 2.6147E-09 1.2020E+16 1.1994E+10 1-133 4.9081E-02 4.3327E-11 1.9618E+14 1.8160E+09 I-135 2.5589E-04 7.2866E-14 3.2504E+11 9.4681E+06 Xe-133 7.4017E+01 3.9543E-07 1.7905E+18 2.7386E+12 Xe-135 1.6102E-01 6.3053E-11 2.8127E+14 5.9577E+09 Control Room Transport Group Inventory:
Overlying
ICALCULATION NOC-I 101-900-EOOO-083 REV. No. 2 PAGE NO. 136 Time (h) = 72.5000 Atmosphere Sump Pool Noble gases (atoms) 2.9547E+19 O.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 6.9776E+15 0.0000E+00 0.OOOOE+00 Organic I (atoms) 5.2638E+15 0.OOOOE.00 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 0.0000E+00 Deposition Recirculating Time (h) = 72.5000 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 72.5000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 72.5000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 72.5000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 74.0000 Whole Body Thyroid TEDE Delta dose (rem) 4.8991E-02 1.3212E+01 4.5189E-01 Accumulated dose (rem) 4.8450E-01 1.3150E+02 4.4948E+00 Low Population Zone Doses:
Time (h) = 74.0000 Whole Body Thyroid TEDE Delta dose (rem) 8.5734E-03 2.3121E+00 7.9082E-02 Accumulated dose (rem) 8.4787E-02 2.3012E+01 7.8658E-01 Control Room Doses:
Time (h) = 74.0000 Whole Body Thyroid TEDE Delta dose (rem) 7.7707E-03 1.0306E+01 3.2207E-01 Accumulated dose (rem) 1.3047E-02 3.5496E+01 1.0955E+00 Control Room Compartment Nuclide Inventory:
Time (h) = 74.0000 Ci kg Atoms Bq Kr-85 1.1834E-01 3.0163E-07 2.1370E+18 4.3786E+09 Kr-85m 1.4054E-05 1.7077E-15 1.2099E+10 5.1998E+05 Kr-88 5.2612E-08 4.1958E-18 2.8713E+07 1.9467E+03 1-131 6.4593E-05 5.2102E-13 2.3951E+12 2.3899E+06 I-133 9.3534E-06 8.2568E-15 3.7386E+10 3.4607E+05 I-135 4.3804E-08 1.2473E-17 5.5641E+07 1.6207E+03 Xe-133 5.6530E+00 3.0200E-08 1.3675E+17 2. 0916E+11
I CALCULATION NOC-I 10I-900-EOOO-083 l REV. No. 2 lTPAGE NO. 137 l Xe-135 1.1060E-02 4.3307E-12 1.9319E+13 4.092OE+08 Control Room Transport Group Inventory:
Overlying Time (h) = 74.0000 Atmosphere Sump Pool Noble gases (atoms) 2.2753E+18 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 1.3979E+12 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) 1.0545E+12 0.OOOOE+00 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Deposition Recirculating Time (h) = 74.0000 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 5.4600E+15 Organic I (atoms) 0.OOOOE+00 4.1189E+15 Aerosols (kg) 0.OOOOE+00 0.0000E+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 74.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 4.5573E+20 Organic I (atoms) 3.4379E+20 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 74.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 74.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 2.1320E+15 Organic I (atoms) 1.6083E+15 Aerosols (kg) 0.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 80.0000 Whole Body Thyroid TEDE Delta dose (rem) 2.6487E-05 0.OOOOE+00 2.6487E-05 Accumulated dose (rem) 4.8453E-01 1.3150E+02 4. 4948E+00 Low Population Zone Doses:
Time (h) = 80.0000 Whole Body Thyroid TEDE Delta dose (rem) 1.9865E-06 0.OOOOE+00 1.9865E-06 Accumulated dose (rem) 8.4789E-02 2.3012E+01 7.8658E-01 Control Room Doses:
Time (h) = 80.0000 Whole Body Thyroid TEDE Delta dose (rem) 4.8847E-04 1.8880E-03 5.4605E-04 Accumulated dose (rem) 1.3535E-02 3.5498E+01 1.0961E+00 Control Room Compartment Nuclide Inventory:
Time (h) = 80.0000 Ci kg Atoms Bq Kr-85 8.9354E-07 2.2775E-12 1.6136E+13 3.3061E+04 Xe-133 4.1298E-05 2.2063E-13 9.9900E+l1 1.5280E+06
I CALCULATION NOC-1 101-900-EOOO.083 I REV. No. 2 l PAGE NO. 138 Xe-135 5.2849E-08 2.0695E-17 9.2317E+07 1.9554E+03 Control Room Transport Group Inventory:
Overlying Time (h) = 80.0000 Atmosphere Sump Pool Noble gases (atoms) 1.7181E+13 0.0000E+00 0.OOOOE+00 Elemental I (atoms) 7.6605E-07 0.0000E+00 0.OOOOE+00 Organic I (atoms) 5.7790E-07 0.0000E+00 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Deposition Recirculating Time (h) = 80.0000 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 5.4610E+15 Organic I (atoms) 0.OOOOE+00 4.1197E+15 Aerosols (kg) 0.OOOOE+00 0.0000E+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 80.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 4.5573E+20 Organic I (atoms) 3.4379E+20 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 80.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 80.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 2.1324E+15 Organic I (atoms) 1.6086E+15 Aerosols (kg) 0.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 96.0000 Whole Body Thyroid TEDE Delta dose (rem) 1.9243E-10 0.OOOOE+00 1.9243E-10 Accumulated dose (rem) 4.8453E-01 1.3150E+02 4.4948E+00 Low Population Zone Doses:
Time (h) = 96.0000 Whole Body Thyroid TEDE Delta dose (rem) 9.3811E-12 0.0000E+00 9.3811E-12 Accumulated dose (rem) 8.4789E-02 2.3012E+01 7.8658E-01 Control Room Doses:
Time (h) = 96.0000 Whole Body Thyroid TEDE Delta dose (rem) 3.5487E-09 1.0087E-21 3.5487E-09 Accumulated dose (rem) 1.3535E-02 3.5498E+01 1.0961E+00 Control Room Compartment Nuclide Inventory:
Time (h) = 96.0000 Ci kg Atoms Bq Control Room Transport Group Inventory:
CALCULATION NOC-I 101 -900-EOOO-083 l REV. No. 2 l PAGE NO. 139 l Overlying Time (h) = 96.0000 Atmosphere Sump Pool Noble gases (atoms) 3.6913E-01 0.OOOOE+00 0.0000E+00 Elemental I (atoms) 1.5380E-55 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) 1.1603E-55 0.OOOOE+00 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Deposition Recirculating Time (h) = 96.0000 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 5.4610E+15 Organic I (atoms) 0.OOOOE+00 4.1197E+15 Aerosols (kg) 0.0000E+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 4.5573E+20 Organic I (atoms) 3.4379E+20 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 2.1324E+15 Organic I (atoms) 1.6086E+15 Aerosols (kg) 0.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 168.0000 Whole Body Thyroid TEDE Delta dose (rem) 3.7707E-24 0.OOOOE+00 3.7707E-24 Accumulated dose (rem) 4.8453E-01 1.3150E+02 4.4948E+00 Low Population Zone Doses:
Time (h) = 168.0000 Whole Body Thyroid TEDE Delta dose (rem) 7.5414E-26 0.OOOOE+00 7.5414E-26 Accumulated dose (rem) 8.4789E-02 2.3012E+01 7. 8658E-01 Control Room Doses:
Time (h) = 168.0000 Whole Body Thyroid TEDE Delta dose (rem) 8.5077E-23 7.6716E-70 8.5077E-23 Accumulated dose (rem) 1.3535E-02 3.5498E+01 1.0961E+00 Control Room Compartment Nuclide Inventory:
Time (h) = 168.0000 Ci kg Atoms Bq Control Room Transport Group Inventory:
Overlying Time (h) = 168.0000 Atmosphere Sump Pool
CALCULATION NOC-I 101-900-EOOO-083 l REV. No. 2 l PAGE NO. 140 l Noble gases (atoms) 1.1284E-62 0.OOOOE+00 O.OOOOE+00 Elemental I (atoms) 1.1161-274 0.OOOOE+00 0.0000E+00 Organic I (atoms) 8.4194-275 0.OOOOE+00 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 o.OOOOE+00 Deposition Recirculating Time (h) = 168.0000 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 O.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 5.4610E+15 Organic I (atoms) 0.0000E+00 4.1197E+15 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 168.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 4.5573E+20 Organic I (atoms) 3.4379E+20 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 168.0000 Filter Noble gases (atoms) O.0000E+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 168.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 2.1324E+15 Organic I (atoms) 1.6086E+15 Aerosols (kg) 0.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 720.0000 Whole Body Thyroid TEDE Delta dose (rem) 7.7374E-86 0.OOOOE+00 7.7374E-86 Accumulated dose (rem) 4.8453E-01 1.3150E+02 4.4948E+00 Low Population Zone Doses:
Time (h) = 720.0000 Whole Body Thyroid TEDE Delta dose (rem) 3.8687E-88 0.0000E+00 3.8687E-88 Accumulated dose (rem) 8.4789E-02 2.3012E+01 7.8658E-01 Control Room Doses:
Time (h) = 720.0000 Whole Body Thyroid TEDE Delta dose (rem) 2.2404E-84 5.6683-289 2.2404E-84 Accumulated dose (rem) 1.3535E-02 3.5498E+01 1.0961E+00 Control Room Compartment Nuclide Inventory:
Time (h) = 720.0000 Ci kg Atoms Bq Control Room Transport Group Inventory:
Overlying Time (h) = 720.0000 Atmosphere Sump Pool Noble gases (atoms) 0.0000E+00 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.0000E+00 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) 0.0000E+00 0.0000E+00 0.OOOOE+00
CALCULATION NOC-I 101 -900-EOOO-083 I REV. No. 2 I PAGE NO. 141 l Aerosols (kg) 0.OOOOE+00 0.OOOOE+00O0.OOOOE+00 Deposition Recirculating Time (h) = 720.0000 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 5.4610E+15 Organic I (atoms) 0.OOOOE+00 4.1197E+15 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 4.5573E+20 Organic I (atoms) 3.4379E+20 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 2.1324E+15 Organic I(atoms) 1.6086E+15 Aerosols (kg) 0.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 792.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Accumulated dose (rem) 4.8453E-01 1.3150E+02 4.4948E+00 Low Population Zone Doses:
Time (h) = 792.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.OOOOE+00 0.OOOOE+00 Accumulated dose (rem) 8.4789E-02 2 .3012E+01 7.8658E-01 Control Room Doses:
Time (h) = 792.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.OOOOE+00 0.OOOOE+00 Accumulated dose (rem) 1.3535E-02 3.5498E+01 1.0961E+00 Control Room Compartment Nuclide Inventory:
Time (h) = 792.0000 Ci kg Atoms Bq Control Room Transport Group Inventory:
Overlying Time (h) = 792.0000 Atmosphere Sump Pool Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 0.0000E+00 0.OOOOE+00 Deposition Recirculating
CALCULATION NOC-1 101-900-EOOO-083 REV. No. 2 PAGE NO. 142 Time (h) = 792.0000 Surfaces Filter Noble gases (atoms) o.OOOOE+00 0.0000E+00 Elemental I (atoms) 0.OOOOE+00 5.4610E+15 Organic I (atoms) 0.OOOOE+00 4.1197E+15 Aerosols (kg) 0.OOOOE+00 0.0000E+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 792.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 4.5573E+20 Organic I (atoms) 3.4379E+20 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 792.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) o.0000E+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 792.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 2.1324E+15 Organic I (atoms) 1.6086E+15 Aerosols (kg) 0.0000E+00 334 1-131 Summary Containment Environment Control Room Time (hr) 1-131 (Curies) I-131 (Curies) I-131 (Curies) 72.001 6.5355E+01 8.3646E-02 1.0538E-04 72.004 4.2054E+02 3.4959E+00 4.3989E-03 72.400 6.7659E+01 3.5615E+02 3.3229E-01 72.500 4.2673E+01 3.8115E+02 3.2416E-01 72.800 1.0706E+01 4.1309E+02 4.6996E-02 73.100 2.6861E+00 4.2110E+02 7.6012E-03 73.400 6.7390E-01 4.2311E+02 1.3958E-03 73.700 1.6907E-01 4.2362E+02 2.8780E-04 74.000 4.2419E-02 4.2374E+02 6.4593E-05 74.300 4.2373E-02 4.2374E+02 7.8824E-06 74.600 4.2328E-02 4.2374E+02 9.6189E-07 74.900 4.2282E-02 4.2374E+02 1.1738E-07 75.200 4.2236E-02 4.2374E+02 1.4324E-08 75.500 4.2191E-02 4.2374E+02 1.7480E-09 75.800 4.2146E-02 4.2374E+02 2.1331E-10 76.100 4.2100E-02 4.2374E+02 2.6031E-11 76.400 4.2055E-02 4.2374E+02 3.1765E-12 76.700 4.2010E-02 4.2374E+02 3.8764E-13 77.000 4.1964E-02 4.2374E+02 4.7304E-14 77.300 4.1919E-02 4.2374E+02 5.7726E-15 77.600 4.1874E-02 4.2374E+02 7.0443E-16 77.900 4.1829E-02 4.2374E+02 8.5963E-17 78.200 4.1784E-02 4.2374E+02 1.0490E-17
- 78. 500 4.1739E-02 4.2374E+02 1.2801E-18 78.800 4.1694E-02 4.2374E+02 1.5622E-19 79.100 4.1649E-02 4.2374E+02 1.9063E-20 79.400 4.1604E-02 4.2374E+02 2.3263E-21
CALCULATION NOC-I 101-900-EOO-083 I REV. No. 2 1 PAGE NO. 143 79.700 4 .1559E-02 4.2374E+02 2.8388E-22 80.000 4.1514E-02 4.2374E+02 3.4643E-23 80.300 4.1470E-02 4.2374E+02 4.2275E-24 80.600 4.1425E-02 4.2374E+02 5.1588E-25 80.900 4.1380E-02 4.2374E+02 6.2954E-26 81.200 4 .1336E-02 4.2374E+02 7.6824E-27 81.500 4 .1291E-02 4.2374E+02 9.3749E-28 81.800 4.1247E-02 4.2374E+02 1.1440E-28 82.100 4.1202E-02 4.2374E+02 1.3961E-29 82.400 4.1158E-02 4.2374E+02 1.7036E-30 96.000 3.9196E-02 4.2374E+02 6.5668E-72 168.000 3.0263E-02 4.2374E+02 3.6792-291 720.000 4 .1664E-03 4.2374E+02 O.OOOOE+00 792.000 3.2169E-03 4.2374E+02 O.OOOOE+00 Cumulative Dose Summary Exclusion Area Bounda Low Population Zone Contro]l Room Time Thyroid TEDE Thyroid TEDE Thyroid TEDE (hr) (rem) (rem) (rem) (rem) (rem) (rem) 72.001 2.5952E-02 8.8702E-04 4.5415E-03 1.5523E-O' 5.7730E-06 1.7727E-07 72.004 1.0846E+00 3.7073E-02 1.8981E-01 6.4878E-O-3 1.2176E-03 3.7387E-05 72.400 1.1053E+02 3.7778E+00 1.9343E+01 6.6111E-0:L 1.8717E+01 5.7473E-01 72.500 1.1829E+02 4.0429E+00 2.0700E+01 7.0750E-0:L 2.5190E+01 7.7347E-01 72.800 1.2819E+02 4.3816E+00 2.2434E+01 7.6678E-0:L 3.3917E+01 1.0430E+00 73.100 1.3068E+02 4.4667E+00 2.2869E+01 7.8166E-0:I 3.5224E+01 1.0849E+00 73.400 1.3130E+02 4.4880E+00 2.2978E+01 7.8540E-0OL 3.5445E+01 1.0929E+00 73.700 1.3146E+02 4.4934E+00 2.3005E+01 7.8634E-0:L 3.5487E+01 1.0949E+00 74.000 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-0:L 3.5496E+01 1.0955E+00 74.300 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-O0L 3.5497E+01 1.0958E+00 74.600 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-O:L 3.5498E+01 1.0959E+00 74.900 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-0:L 3.5498E+01 1.0960E+00 75.200 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-O0L 3.5498E+01 1.0960E+00 75.500 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-0:L 3.5498E+01 1.0961E+00 75.800 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-0:L 3.5498E+01 1.0961E+00 76.100 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-O0L 3.5498E+01 1.0961E+00 76.400 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-0: 3.5498E+01 1. 0961E+00 76.700 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01L 3.5498E+01 1.0961E+00
- 77. 000 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-0:L 3.5498E+01 1.0961E+00 77.300 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01I 3.5498E+01 1.0961E+00 77.600 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.5498E+01 1.0961E+00 77.900 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.5498E+01 1.0961E+00 78.200 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-0: 3.5498E+01 1.0961E+00 78.500 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-0O 3.5498E+01 1.0961E+00 78.800 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-0O 3.5498E+01 1.0961E+00 79.100 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-OJ 3.5498E+01 1. 0961E+00 79.400 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-0O 3.5498E+01 1.0961E+00 79.700 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.5498E+01 1. 0961E+00 80.000 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-0O 3.5498E+01 1.0961E+00 80.300 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-Ol 3.5498E+01 1.0961E+00 80.600 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.5498E+01 1.0961E+00 80.900 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.5498E+01 1.0961E+00 81.200 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.5498E+01 1.0961E+00 81.500 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.5498E+01 1.0961E+00 81.800 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.5498E+01 1.0961E+00 82.100 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.5498E+01 1.0961E+00 82.400 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.5498E+01 1. 0961E+00
- 96. 000 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.5498E+01 1.0961E+00 168.000 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.5498E+01 1.0961E+00 720. 000 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.5498E+01 1. 0961E+00 792.000 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.5498E+01 1.0961E+00 Worst Two-Hour Doses Note: All of the dose locations are shown below but the worst two-hour dose is only meaningful for the EAB
I CALCULATION NOC- I10 -900-EOOO-083 l REV. No. 2 l PAGE NO. 144 l dose location. Please disregard the two-hour worst doses for the other dose locations Exclusion Area Boundar3 Time Whole Body Thyroid TEDE (hr) (rem) (rem) (rem) 72.0 4.8440E-01 1.3147E+02 4.4939E+00 Low Population Zone Time Whole Body Thyroid TEDE (hr) (rem) (rem) (rem) 72.0 8.4771E-02 2.3008E+01 7.8643E-01 Control Room Time Whole Body Thyroid TEDE (hr) (rem) (rem) (rem) 72.0 1.3047E-02 3.5496E+01 l.0955E+00
CALCULATION NOC-1 101-900-EOOO-083 lTREV. No. 2 l PAGE NO. 145 Appendix I RADTRAD, File OG.psf FHA Occurring In Reactor Building With Hatch Doors Opened CR Recirc Flow: 30,800 cffn CR Filtered Intake Flow: 8,800 cfm CR Unfiltered Inleakage: 1,000 cfm CR Exhaust Flow: 9,800 cfm Two Times Iodine & Noble Gas Release Fractions
I CALCULATION NOC-1 101-900-E000-083 l REV. No. 2 T PAGE NO. 146 l RADTRAD Version 3.02 run on 7/07/2005 at 7:53:39 File information Plant file name = C:\Program Files\U S Nuclear Regulatory Commission\Radtrad\0G.psf Inventory file name = c:\program files\u s nuclear regulatory commission\radtrad\defaults\fharb_def_a.nif Scenario file name = C:\Program Files\U S Nuclear Regulatory Commission\Radtrad\OG.psf Release file name = c:\program files\u s nuclear regulatory commission\radtrad\defaults\fha update 6-9-05.rft Dose conversion file name = c:\program files\u s nuclear regulatory commission\radtrad\defaults\fgrll&12.inp
- ##t## ##~### # # # ##i### # # #####t
- t # # # # # # #t # #
- # # #t #### ~# # # # #
- #### #### #t # # # #t#### # # #
- t #I # # # # # # #t #
- t # ##t ##t #t # # #t
- t #### # # #t #t #t I### #
Radtrad 3.02 1/5/2000 TMI-1 FHAIC With Hatch Doors Opened, AST Analysis, CR Charcoal Filter Efficiency =
75%., CR Recirc = 30,800 cfm, CR Intake = 9,800 cfm Nuclide Inventory File:
c:\program files\u s nuclear regulatory commission\radtrad\defaults\fharb_def_a.nif Plant Power Level:
2.6190E+03 Compartments:
3 Compartment 1:
Containment 3
2.1600E+06 0
0 0
0 0
Compartment 2:
Environment 2
0.OOOOE+00 0
0 0
0 0
Compartment 3:
Control Room 1
2.5000E+05 0
0 1
0
CALCULATION NOC-I 101-900-EOOO-083 I REV. No. 2 l PAGE NO. 147 0
Pathways:
4 Pathway 1:
Containment t:o Environment 1
2 2
Pathway 2:
Control Room Air Intake 2
3 2
Pathway 3:
Control Room Unfiltered Inleakage 2
3 2
Pathway 4:
Control Room Exhaust to Environment 3
2 2
End of Plant Model File Scenario Description Name:
Plant Model Filename:
Source Term:
1 1 1.0000E+00 c:\program files\u s nuclear regulatory commission\radtrad\defaults\fgrll&12.inp c:\program files\u s nuclear regulatory commission\radtrad\defaults\fha update 6 05.rft 7.2000E+01 0
O.0000E+00 5.7000E-01 4.3000E-01 1.0000E+00 Overlying Pool:
0 0.0000E+00 0
0 0
0 Compartments:
3 Compartment 1:
0 1
0 0
0 0
0 0
0 Compartment 2:
0 1
0 0
0 0
0 0
0 Compartment 3:
1
I CALCULATION NOC-101-900-EOOO-083 I REV. No. 2 l PAGE NO. 148 1
0 0
0 0
1 3.0800E+04 3
7 .2000E+01 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 7 .2500E+01 9.9000E+01 7.5000E+O1 7.5000E+01 7.9200E+02 9.9000E+01 7.5000E+O1 7.5000E+01 0
0 Pathways:
4 Pathway 1:
0 0
0 0
0 1
3 7 .2000E+01 1.6580E+05 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 7.4000E+01 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00
- 7. 9200E+02 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 0
0 0
0 0
0 Pathway 2:
0 0
0 0
0 1
3 7 .2000E+01 4.OOOOE+03 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 7 .2500E+01 8.8000E+03 9.9000E+01 7.5000E+O1 7.5000E+01
- 7. 9200E+02 O.OOOOE+O0 O.OOOOE+00 O.OOOOE+O0 O.OOOOE+00 0
0 0
0 0
0 Pathway 3:
0 0
0 0
0 1
2 7 .2000E+01 l.OOOOE+03 O.OOOOE+00 O.OOOOE+0O O.OOOOE+00 7 .9200E+02 O.OOOOE+00 O.OOOOE+00 O.OOOOE+0O O.OOOOE+00 0
0 0
0 0
0 Pathway 4:
0 0
CALCULATION NOC-1 101-900-EOOO-083 l REV. No. 2 l PAGE NO. 149 0
0 0
1 3
7.2000E+01 5.OOOOE+03 O.OOOOE+00 O.OOOOE+00 0.OOOOE+00 7.2500E+01 9. 8000E+03 1.OOOOE+02 1.OOOOE+02 1.OOOOE+02 7.9200E+02 0.OOOOE+00 0.OOOOE+00 O.OOOOE+O0 0.OOOOE+00 0
0 0
0 0
0 Dose Locations:
3 Location 1:
Exclusion Area Boundary 2
1 2
7.2000E+01 8.OOOOE-04 7.2000E+02 O.OOOOE+O0 1
2 7.2000E+01 3.5000E-04 7.2000E+02 O.OOOOE+00 0
Location 2:
Low Population Zone 2
1 6
7.2000E+01 1.4000E-04 7.4000E+01 6.OOOOE-05
- 8. OOOOE+01 3.9000E-05 9.6000E+01 1.6000E-05 1.6800E+02 4.OOOOE-06 7.9200E+02 O.OOOOE+00 1
4 7.2000E+01 3.5000E-04 8.OOOOE+01 1.8000E-04 9.6000E+01 2.3000E-04 7.9200E+02 O.OOOOE+0O 0
Location 3:
Control Room 3
0 1
2 7.2000E+01 3.5000E-04 7.9200E+02 O.OOOOE+00 1
4 7.2000E+O1 l.OOOOE+O0 9.6000E+01 6.OOOOE-01 1.6800E+02 4.OOOOE-01 7.9200E+02 O.OOOOE+00 Effective Volume Location:
1 6
7.2000E+01 5.34OOE-04 7.4000E+01 3.1000E-04 8.OOOOE+01 1.3600E-04
- 9. 6000E+01 9.7000E-05 1.6800E+02 6.0200E-05
CALCULATION NOC-1101-900-EOOO-083 @REV. No. 2 l PAGE NO. 150 l 7.9200E+02 O.OOOOE+00 Simulation Parameters:
6 7.2000E+01 1.OOOOE-01 7.4000E+01 5.OOOOE-01 8.OOOOE+01 1.OOOOE+OO 9.6000E+01 2.0000E+00 1.6800E+02 4.OOOOE+OO 7.9200E+02 O.OOOOE+O0 Output Filename:
C:\Program Files\U S Nuclear Regulatory Commission\Radtrad\OG.ol 1
1 0
0 End of Scenario File RADTRAD Version 3.02 run on 7/07/2005 at 7:53:39 Plant Description Number of Nuclides = 60 Inventory Power = l.OOOOE+00 MWth Plant Power Level = 2.6190E+03 MWth Number of compartments = 3 Compartment information Compartment number 1 (Source term fraction = l.OOOOE+O0
)
Name: Containment Compartment volume = 2.1600E+06 (Cubic feet)
Pathways into and out of compartment 1 Pathway to compartment number 2: Containment to Environment Compartment number 2 Name: Environment Pathways into and out of compartment 2 Pathway to compartment number 3: Control Room Air Intake Pathway to compartment number 3: Control Room Unfiltered Inleakage Pathway from compartment number 1: Containment to Environment Pathway from compartment number 3: Control Room Exhaust to Environment Compartment number 3 Name: Control Room Compartment volume = 2.5000E+05 (Cubic feet)
Removal devices within compartment:
Filter(s)
Pathways into and out of compartment 3 Pathway to compartment number 2: Control Room Exhaust to Environment Pathway from compartment number 2: Control Room Air Intake Pathway from compartment number 2: Control Room Unfiltered Inleakage Total number of pathways = 4 RADTRAD Version 3.02 run on 7/07/2005 at 7:53:39
I CALCULATION NOC-101I-900-EOOO-083 IREV. No. 2 lPAGE NO. 151 Scenario Description Time between shutdown and first release = 7.2000E+01 (Hours)
Radioactive Decay is enabled RELEASENAME = RG-1.183, Tables 3 Section 3.2 Release Fractions and Timings GAP EARLY IN-VESSEL 0.0036 hrs 0.0000 hrs NOBLES 1.0000E-01 0.0000E+00 IODINE 1.0000E-01 0.OOOOE+00 CESIUM 0.OOOOE+00 0.0000E+00 TELLURIUM 0.0000E+00 0.OOOOE+00 STRONTIUM 0.OOOOE+00 0.OOOOE+00 BARIUM 0.OOOOE+00 0.OOOOE+00 RUTHENIUM 0.OOOOE+00 0.OOOOE+00 CERIUM 0.0000E+00 0.OOOOE+00 LANTHANUM O.OOOOE+00 0.OOOOE+00 Iodine fractions Aerosol 0.0000E+00 Elemental 5.7000E-01 Organic 4.3000E-01 COMPARTMENT DATA Compartment number 1: Containment Compartment number 2: Environment Compartment number 3: Control Room Compartment F ilter Data Time (hr) Flow Rate Filter Efficiencies (%)
(cfm) Aerosol Elemental Organic 7.2000E+01 3.0800E+04 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 7.2500E+01 3.0800E+04 9.9000E+01 7.5000E+01 7.5000E+01 7.9200E+02 3.0800E+04 9.9000E+01 7.5000E+01 7.5000E+01 PATHWAY DATA Pathway number 1: Containment to Environment Pathway Filter: Removal Data Time (hr) Flow Rate Filter. EfficiencieE (%)
(cfm) Aerosol Elemental Organic 7.2000E+01 1.6580E+05 0.OOOOE+00 0.OOOOE+00 0.0000E+00 7.4000E+01 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.0000E+00 7.9200E+02 O.OOOOE+00 0.OOOOE+00 0.0000E+00 0.OOOOE+00 Pathway number 2: Control Room Air Intake Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)
(cfm) Aerosol Elemental Organic 7.2000E+01 4.OOOOE+03 0.OOOOE+00 0.0000E+00 0.OOOOE+00 7.2500E+01 8.8000E+03 9.9000E+01 7.5000E+01 7.5000E+01 7.9200E+02 0.OOOOE+00 0.OOOOE+00 0.0000E+00 0.OOOOE+00 Pathway number 3: Control Room Unfiltered Inleakage Pathway Filter: Removal Data
CALCULATION NOC-1 101-900-EOOO-083 I REV. No. 2 l PAGE NO. 152 Time (hr) Flow Rate Filter Efficiencies (%)
(cfm) Aerosol Elemental Organic 7.2000E+01 1.OOOOE+03 0.0000E+00 0.0000E+00 O.OOOOE+00 7.9200E+02 0.000OE+00 O.0000E+00 0.0000E+00 0.OOOOE+00 Pathway number 4: Control Room Exhaust to Environment Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)
(cfm) Aerosol Elemental Organic 7.2000E+01 5.OOOOE+03 0.OOOOE+00 0.0000E+00 0.OOOOE+00 7.2500E+01 9.8000E+03 1.0000E+02 1.0000E+02 1.OOOOE+02 7.9200E+02 O.0000E+00 0.OOOOE+00 0.OOOOE+00 O.OOOOE+00 LOCATION DATA Location Exclusion Area Boundary is in compartment 2 Location X/Q Data Time (hr) X/Q (s
- m^-3) 7.2000E+01 8.OOOOE-04 7.2000E+02 O.OOOOE+00 Location Breathing Rate Data Time (hr) Breathing Rate (mA3
- sec^-1) 7.2000E+01 3.5000E-04 7.2000E+02 0.OOOOE+00 Location Low PopulcaLtion Zone is in compartment 2 Location X/Q Data Time (hr) X/S S
- mA-3) 7.2000E+01 1.4000E-04 7.4000E+01 6.0000E-05 8.OOOOE+01 3.9000E-05 9.6000E+01 1.6000E-05 1.6800E+02 4.0000E-06 7.9200E+02 0.0000E+00 Location Breathing Raite Data Time (hr) Br4eathing Rate (mW3
- sec^-1) 7.2000E+01 3.5000E-04 8.OOOOE+01 1.8000E-04 9.6000E+01 2.3000E-04 7.9200E+02 O.0000E+00 Location Control Room is in compartment 3 Location X/Q Data Time (hr) X/(Q (s
- mA-3) 7.2000E+01 5.34OOE-04 7.4000E+01 3.1000E-04 8.OOOOE+01 1.360OE-04 9.6000E+01 9.7000E-05 1.6800E+02 6.0200E-05 7.9200E+02 0.OOOOE+00 Location Breathing Rat:e Data Time (hr) Br(eathing Rate (mA3
- sec^-1) 7.2000E+01 3.5000E-04 7.9200E+02 0.OOOOE+00 Location Occupancy Facctor Data Time (hr) Occ:upancy Factor 7.2000E+01 1.OOOOE+00 9.6000E+01 6.OOOOE-01 1.6800E+02 4.OOOOE-01 7.9200E+02 0.OOOOE+00
lCALCULATION NOC-1101-900-EOOO-083 lREV.No. 2 PAGE NO. 153 USER SPECIFIED TIME STEP DATA - SUPPLEMENTAL TIME STEPS Time Time step 0.0000E+00 1.0000E-01 2.OOOOE+00 5.0000E-01 8.0000E+00 1.OOOOE+00 2.4000E+01 2.OOOOE+00 9.6000E+01 4.OOOOE+00 7.2000E+02 0.0000E+00 RADTRAD Version 3.02 run on 7/07/2005 at 7:53:39 ifif#if # # ###ifif ififififif if
- if if if if if if if # if if # if if #if##if if
- f #f # #f #f
- #f #f
- fi i####f Dose, Detailed model and Detailed Inventory Output EA###i####################yDo######################## ######## #######
Exclusion Area Boundary Doses:
Time (h) = 72.0036 Whole Body Thyroid TEDE Delta dose (rem) 3.9946E-03 1.0846E+00 3.7073E-02 Accumulated dose (rem) 3.9946E-03 1.0846E+00 3.7073E-02 Low Population Zone Doses:
Time (h) = 72.0036 Whole Body Thyroid TEDE Delta dose (rem) 6.9906E-04 1.8981E-01 6.4878E-03 Accumulated dose (rem) 6.9906E-04 1.8981E-01 6.4878E-03 Control Room Doses:
Time (h) = 72.0036 Whole Body Thyroid TEDE Delta dose (rem) 2.5519E-07 1.2176E-03 3.7387E-05 Accumulated dose (rem) 2.5519E-07 1.2176E-03 3.7387E-05 Control Room Compartment Nuclide Inventory:
Time (h) 72.0036 Ci kg Atoms Bq Kr-85 2.0817E-02 5.3058E-08 3.7591E+17 7.7022E+08 Kr-85m 3.3667E-06 4.0910E-16 2.8984E+09 1.2457E+05 Kr-88 1.5065E-08 1.2014E-18 8.2219E+06 5.5741E+02 I-131 4.3989E-03 3.5482E-11 1.6311E+14 1.6276E+08 I-133 6.7593E-04 5.9669E-13 2.7017E+12 2.5009E+07 I-135 3.6515E-06 1.0398E-15 4.6383E+09 1.3511E+05 Xe-133 1.0054E+00 5.3711E-09 2.4320E+16 3.7199E+10 Xe-135 2.2653E-03 8.8705E-13 3.9570E+12 8.3816E+07 Control Room Transport Group Inventory:
Overlying Time (h) = 72.0036 Atmosphere Sump Pool Noble gases (atoms) 4.0024E+17 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 9.4518E+13 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) 7.1303E+13 0.OOOOE+00 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00
II CALCULATION NOC-1 101-900-EOOO-083 CLUAONNC1OI90EO-8IRE.N.2IP IREV. No. 2 IPAGE NO. 154 ENO15 I Deposition Recirculating Time (h) = 72.0036 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) O.OOOOE+00 0.OOOOE+00 Aerosols (kg) 0.0000E+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 72.0036 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 72.0036 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 72.0036 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) o.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 72.5000 Whole Body Thyroid TEDE Delta dose (rem) 4.3151E-01 1.1720E+02 4.0058E+00 Accumulated dose (rem) 4.3551E-01 1.1829E+02 4.0429E+00 Low Population Zone Doses:
Time (h) = 72.5000 Whole Body Thyroid TEDE Delta dose (rem) 7.5515E-02 2.0510E+01 7.OI1OE-01 Accumulated dose (rem) 7.6214E-02 2.0700E+01 7.0750E-01 Control Room Doses:
Time (h) = 72.5000 Whole Body Thyroid TEDE Delta dose (rem) 5.2760E-03 2.5188E+01 7.7343E-01 Accumulated dose (rem) 5.2763E-03 2.5190E+01 7.7347E-01 Control Room Compartment Nuclide Inventory:
Time (h) = 72.5000 Ci kg Atoms Bq Kr-85 1.5368E+00 3.9169E-06 2.7751E+19 5.6860E+10 Kr-85m 2.3017E-04 2.7968E-14 1.9815E+11 8.5162E+06 Kr-88 9.8526E-07 7.8574E-17 5.3771E+08 3.6455E+04 1-131 3.2416E-01 2.6147E-09 1.2020E+16 1.1994E+10 1-133 4.9081E-02 4.3327E-11 1. 9618E+14 1.8160E+09 1-135 2.5589E-04 7.2866E-14 3.2504E+11 9.4681E+06 Xe-133 7.4017E+01 3.9543E-07 1.7905E+18 2.7386E+12 Xe-135 1.6102E-01 6.3053E-11 2.8127E+14 5.9577E+09 Control Room Transport Group Inventory:
Overlying
CALCULATION NOC-1 101-900.EOOO-083 l REV. No. 2 T PAGE NO. 155 l Time (h) = 72.5000 Atmosphere Sump Pool Noble gases (atoms) 2.9547E+19 O.OOOOE+00 0.0000E+00 Elemental I (atoms) 6.9776E+15 0.OOOOE+O0 0.OOOOE+00 Organic I (atoms) 5.2638E+15 0.OOOOE+O0 0.0000E+00 Aerosols (kg) 0.0000E+00 0.OOOOE+00 0.0000E+00 Deposition Recirculating Time (h) = 72.5000 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 O.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 0.0000E+00 Organic I (atoms) 0.OOOOE+00 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 72.5000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 72.5000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 72.5000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 74.0000 Whole Body Thyroid TEDE Delta dose (rem) 4.9020E-02 1.3212E+01 4.5192E-01 Accumulated dose (rem) 4.8453E-01 1.3150E+02 4.4948E+00 Low Population Zone Doses:
Time (h) = 74.0000 Whole Body Thyroid TEDE Delta dose (rem) 8.5784E-03 2.3121E+00 7.9087E-02 Accumulated dose (rem) 8.4792E-02 2.3012E+01 7.8659E-01 Control Room Doses:
Time (h) = 74.0000 Whole Body Thyroid TEDE Delta dose (rem) 6.9537E-03 9.3372E+00 2.9170E-01 Accumulated dose (rem) 1.2230E-02 3.4527E+01 1.0652E+00 Control Room Compartment Nuclide Inventory:
Time (h) = 74.0000 Ci kg Atoms Bq Kr-85 7.4669E-02 1.9032E-07 1.3484E+18 2.7627E+09 Kr-85m 8.8673E-06 1.0775E-15 7.6339E+09 3.2809E+05 Kr-88 3.3197E-08 2.6474E-18 1.8117E+07 1.2283E+03 I-131 4.9853E-05 4. 0213E-13 1.8486E+12 1.8446E+06 1-133 7.2190E-06 6.3727E-15 2.8855E+10 2.6710E+05 1-135 3.3808E-08 9. 6269E-18 4.2944E+07 1.2509E+03 Xe-133 3.5668E+00 1.9055E-08 8.6282E+16 1.3197E+1l
CALCULATION NOC-I 101-900-EOOO-083 - REV. No. 2 l PAGE NO. 156 Xe-135 6.9782E-03 2.7326E-12 1.2189E+13 2.5819E+08 Control Room Transport Group Inventory:
Overlying Time (h) = 74.0000 Atmosphere Sump Pool Noble gases (atoms) 1.4357E+18 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 1.0789E+12 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) 8.1391E+11 0.OOOOE+00 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Deposition Recirculating Time (h) = 74.0000 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 O.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 5.3858E+15 Organic I (atoms) 0.OOOOE+00 4.0630E+15 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 74.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 5.5700E+20 Organic I (atoms) 4.2019E+20 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 74.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 74.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 2.2849E+15 Organic I (atoms) 1.7237E+15 Aerosols (kg) 0.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 80.0000 Whole Body Thyroid TEDE Delta dose (rem) 1.6725E-05 0.OOOOE+00 1.6725E-05 Accumulated dose (rem) 4.8454E-01 1.3150E+02 4.4948E+00 Low Population Zone Doses:
Time (h) = 80.0000 Whole Body Thyroid TEDE Delta dose (rem) 1.2544E-06 0.OOOOE+00 1.2544E-06 Accumulated dose (rem) 8.4794E-02 2.3012E+01 7.8659E-01 Control Room Doses:
Time (h) = 80.0000 Whole Body Thyroid TEDE Delta dose (rem) 2.5845E-04 1.3069E-03 2.9830E-04 Accumulated dose (rem) 1.2488E-02 3.4528E+01 1.0655E+00 Control Room Compartment Nuclide Inventory:
Time (h) = 80.0000 Ci kg Atoms Bq Kr-85 5.6642E-08 1.4437E-13 1.0229E+12 2.0958E+03 Xe-133 2.6179E-06 1.3986E-14 6.3328E+10 9.6864E+04
I CALCULATION NOC-I101-900-EOOO-083 7 REV. No. 2 1 PAGE NO. 157 Xe-135 3.3502E-09 1.3119E-18 5.8521E+06 1.2396E+02 Control Room Transport Group Inventory:
Overlying Time (h) = 80.0000 Atmosphere Sump Pool Noble gases (atoms) 1.0891E+12 0.0000E+00 0.OOOOE+00 Elemental I (atoms) 2.8698E-09 0.0000E+00 0.0000E+00 Organic I (atoms) 2.1649E-09 0.OOOOE+00 0.OOOOE+00 Aerosols (kg) 0.0000E+00 0.OOOOE+00 0.OOOOE+00 Deposition Recirculating Time (h) = 80.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 5.3866E+15 Organic I (atoms) 0.0000E+00 4.0635E+15 Aerosols (kg) 0.0000E+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 80.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 5.5700E+20 Organic I (atoms) 4.2019E+20 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 80.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 80.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 2.2852E+15 Organic I (atoms) 1.7239E+15 Aerosols (kg) 0.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 96.0000 Whole Body Thyroid TEDE Delta dose (rem) 1.2206E-11 0.OOOOE+00 1.2206E-11 Accumulated dose (rem) 4.8454E-01 1.3150E+02 4.4948E+00 Low Population Zone Doses:
Time (h) = 96.0000 Whole Body Thyroid TEDE Delta dose (rem) 5.9504E-13 0.OOOOE+00 5.9504E-13 Accumulated dose (rem) 8.4794E-02 2.3012E+01 7.8659E-01 Control Room Doses:
Time (h) = 96.0000 Whole Body Thyroid TEDE Delta dose (rem) 1.8860E-10 3.3889E-24 1.8860E-10 Accumulated dose (rem) 1.2488E-02 3.4528E+01 1.0655E+00 Control Room Compartment Nuclide Inventory:
Time (h) = 96.0000 Ci kg Atoms Bq Control Room Transport Group Inventory:
CALCULATION NOC-I 10I-900-EOOO-083 l REV. No. 2 l PAGE NO. 158 l Overlying Time (h) = 96.0000 Atmosphere Sump Pool Noble gases (atoms) 5.0579E-05 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 3.8792E-64 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) 2.9264E-64 0.OOOOE+00 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 O.0000E+00 Deposition Recirculating Time (h) = 96.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.OOOOE+00 5.3866E+15 Organic I (atoms) 0.OOOOE+00 4.0635E+15 Aerosols (kg) 0.OOOOE+00 0.0000E+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 5.5700E+20 Organic I (atoms) 4.2019E+20 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 2.2852E+15 Organic I (atoms) 1.7239E+15 Aerosols (kg) 0.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 168.0000 Whole Body Thyroid TEDE Delta dose (rem) 5.1678E-28 0.OOOOE+00 5.1678E-28 Accumulated dose (rem) 4.8454E-01 1.3150E+02 4.4948E+00 Low Population Zone Doses:
Time (h) = 168.0000 Whole Body Thyroid TEDE Delta dose (rem) 1.0336E-29 0.0000E+00 1.0336E-29 Accumulated dose (rem) 8.4794E-02 2.3012E+01 7.8659E-01 Control Room Doses:
Time (h) = 168.0000 Whole Body Thyroid TEDE Delta dose (rem) 1.1417E-26 1.9349E-78 1.1417E-26 Accumulated dose (rem) 1.2488E-02 3.4528E+01 1.0655E+00 Control Room Compartment Nuclide Inventory:
Time (h) = 168.0000 Ci kg Atoms Bq Control Room Transport Group Inventory:
Overlying Time (h) = 168.0000 Atmosphere Sump Pool
I CALCULATION NOC-I101-900-EOOO-083 l REV. No. 2 l PAGE NO. 159 l Noble gases (atoms) 1.5550E-78 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 4.7165-311 O.OOOOE+00 o.OOOOE+00 Organic I (atoms) 3.5581-311 0.OOOOE+00 o.OOOOE+00 Aerosols (kg) 0.0000E+00 o.0000E+00 0.OOOOE+00 Deposition Recirculating Time (h) = 168.0000 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 5.3866E+15 Organic I (atoms) O.OOOOE+00 4.0635E+15 Aerosols (kg) O.OOOOE+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 168.0000 Filter Noble gases (atoms) O.OOOOE+00 Elemental I (atoms) 5.5700E+20 Organic I (atoms) 4.2019E+20 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 168.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 168.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 2.2852E+15 Organic I (atoms) 1.7239E+15 Aerosols (kg) 0.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 720.0000 Whole Body Thyroid TEDE Delta dose (rem) 1.0663-101 0.OOOOE+00 1.0663-101 Accumulated dose (rem) 4.8454E-01 1.3150E+02 4.4948E+00 Low Population Zone Doses:
Time (h) = 720.0000 Whole Body Thyroid TEDE Delta dose (rem) 5.3315-104 0.OOOOE+00 5.3315-104 Accumulated dose (rem) 8.4794E-02 2.3012E+01 7.8659E-01 Control Room Doses:
Time (h) = 720.0000 Whole Body Thyroid TEDE Delta dose (rem) 3.0855-100 0.OOOOE+00 3.0855-100 Accumulated dose (rem) 1.2488E-02 3.4528E+01 1.0655E+00 Control Room Compartment Nuclide Inventory:
Time (h) = 720.0000 Ci kg Atoms Bq Control Room Transport Group Inventory:
Overlying Time (h) = 720.0000 Atmosphere Sump Pool Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.0000E+00 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00
CALCULATION NOC-1101-900-EOOO-083 I REV. No. 2 T PAGE NO. 160 Aerosols (kg) O.0000E+00 O.0000E+00 O.0000E+00 Deposition Recirculating Time (h) = 720.0000 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 0.0000E+00 Elemental I (atoms) 0.OOOOE+00 5.3866E+15 Organic I (atoms) 0.OOOOE+00 4.0635E+15 Aerosols (kg) O.0000E+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.00OOE+00 Elemental I (atoms) 5.5700E+20 Organic I (atoms) 4.2019E+20 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 2.2852E+15 Organic I (atoms) 1.7239E+15 Aerosols (kg) 0.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 792.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Accumulated dose (rem) 4.8454E-01 1.3150E+02 4.4948E+00 Low Population Zone Doses:
Time (h) = 792.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Accumulated dose (rem) 8.4794E-02 2.3012E+01 7. 8659E-01 Control Room Doses:
Time (h) = 792.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Accumulated dose (rem) 1.2488E-02 3.4528E+01 1.0655E+00 Control Room Compartment Nuclide Inventory:
Time (h) = 792.0000 Ci kg Atoms Bq Control Room Transport Group Inventory:
Overlying Time (h) = 792.0000 Atmosphere Sump Pool Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Deposition Recirculating
I CALCULATION NOC-1 101-900-EOOO-083 I REV. No. 2 1 PAGE NO. 161 Time (h) = 792.0000 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 0.0000E+00 Elemental I (atoms) 0.OOOOE+00 5.3866E+15 Organic I (atoms) 0.OOOOE+00 4.0635E+15 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 792.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 5.5700E+20 Organic I (atoms) 4.2019E+20 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 792.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 792.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 2.2852E+15 Organic I (atoms) 1.7239E+15 Aerosols (kg) 0.OOOOE+00 334 1-131 Summary Containment Environment Control Room Time (hr) I-131 (Curies) I-131 (Curies) I-131 (Curies) 72.001 6.5355E+01 8.3646E-02 1.0538E-04 72.004 4.2054E+02 3.4959E+00 4.3989E-03 72.400 6.7659E+01 3.5615E+02 3.3229E-01 72.500 4.2673E+01 3.8115E+02 3.2416E-01 72.800 1.0706E+01 4.1309E+02 3.7888E-02 73.100 2.6861E+00 4.2110E+02 5.4444E-03 73.400 6.7390E-01 4.2311E+02 9.8623E-04 73.700 1.6907E-01 4.2362E+02 2.1194E-04 74.000 4.2419E-02 4.2374E+02 4.9853E-05 74.300 4.2373E-02 4.2374E+02 4.6609E-06 74.600 4.2328E-02 4.2374E+02 4.3576E-07 74.900 4.2282E-02 4.2374E+02 4.0740E-08 75.200 4.2236E-02 4.2374E+02 3.8089E-09 75.500 4.2191E-02 4.2374E+02 3.5610E-10 75.800 4.2146E-02 4.2374E+02 3.3292E-11 76.100 4.2100E-02 4.2374E+02 3.1126E-12 76.400 4.2055E-02 4.2374E+02 2.9100E-13 76.700 4.2010E-02 4.2374E+02 2.7206E-14 77.000 4.1964E-02 4.2374E+02 2.5436E-15 77.300 4.1919E-02 4.2374E+02 2.3781E-16 77.600 4.1874E-02 4.2374E+02 2.2233E-17 77.900 4.1829E-02 4.2374E+02 2.0786E-18 78.200 4.1784E-02 4.2374E+02 1.9433E-19 78.500 4.1739E-02 4.2374E+02 1.8169E-20 78.800 4.1694E-02 4.2374E+02 1.6986E-21 79.100 4.1649E-02 4.2374E+02 1.5881E-22 79.400 4.1604E-02 4.2374E+02 1.4847E-23
I CALCULATION NOC-10 I1-900-EOOO-083 I REV. No. 2 TPAGE NO. 162 79.700 4.1559E-02 4.2374E+02 1.3881E-24 80.000 4.1514E-02 4.2374E+02 1.2978E-25 80.300 4.1470E-02 4.2374E+02 1.2133E-26
- 80. 600 4.1425E-02 4.2374E+02 1.1344E-27 80.900 4.1380E-02 4.2374E+02 1.0605E-28 81.200 4.1336E-02 4.2374E+02 9.9151E-30 81.500 4.1291E-02 4.2374E+02 9.2699E-31 81.800 4.1247E-02 4.2374E+02 8.6666E-32 82.100 4.1202E-02 4.2374E+02 8.1026E-33 82.400 4.1158E-02 4.2374E+02 7.5753E-34 96.000 3 .9196E-02 4.2374E+02 1.6563E-80 168. 000 3.0263E-02 4.2374E+02 O.OOOOE+00 720. 000 4.1664E-03 4.2374E+02 O.OOOOE+00 792.000 3 .2169E-03 4.2374E+02 O.OOOOE+00 Cumulative Dose Summary Exclusion Area Bounda Low Population Zone Contro] 1 Room Time Thyroid TEDE Thyroid TEDE Thyroid TEDE (hr) (rem) (rem) (rem) (rem) (rem) (rem) 72.001 2.5952E-02 8.8702E-04 4.5415E-03 1.5523E-04 5.7730E-06 1.7727E-07 72.004 1.0846E+00 3.7073E-02 1.8981E-01 6.4878E-03 1.2176E-03 3.7387E-05 72.400 1.1053E+02 3.7778E+00 1.9343E+01 6.6111E-01 1.8717E+01 5.7473E-01 72.500 1.1829E+02 4.0429E+00 2.0700E+01 7.0750E-01 2.5190E+01 7.7347E-01 72.800 1.2819E+02 4.3816E+00 2.2434E+01 7.6679E-01 3.3326E+01 1.0248E+00 73.100 1.3068E+02 4.4667E+00 2.2869E+01 7.8167E-01 3.4334E+01 1.0575E+00 73.400 1.3130E+02 4.4881E+00 2.2978E+01 7.8541E-01 3.4490E+01 1.0633E+00 73.700 1.3146E+02 4.4934E+00 2.3005E+01 7.8635E-01 3 .4520E+01 1.0647E+00 74.000 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.4527E+01 1.0652E+00 74.300 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.4528E+01 1.0653E+00
- 74. 600 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.4528E+01 1.0654E+00 74.900 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.4528E+01 1.0654E+00 75.200 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.4528E+0l 1.0655E+00 75.500 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.4528E+0l 1.0655E+00 75.800 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.4528E+0l 1.0655E+00 76.100 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.4528E+01 1.0655E+00 76.400 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.4528E+01 1.0655E+00 76.700 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.4528E+0l 1.0655E+00 77.000 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.4528E+0l 1.0655E+00 77.300 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.4528E+01 1.0655E+00 77.600 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.4528E+0l 1.0655E+00 77.900 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.4528E+01 1.0655E+00 78.200 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-0l 3.4528E+0l 1.0655E+00 78.500 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.4528E+01 1.0655E+00 78.800 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.4528E+01 1.0655E+00 79.100 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.4528E+01 1.0655E+00 79.400 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.4528E+01 1.0655E+00 79.700 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.4528E+01 1.0655E+00
- 80. 000 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.4528E+01 1.0655E+00 80.300 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.4528E+01 1.0655E+00
- 80. 600 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.4528E+01 1.0655E+00 80.900 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.4528E+0l 1.0655E+00 81.200 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.4528E+01 1.0655E+00 81.500 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-Ol 3.4528E+01 1.0655E+00
- 81. 800 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.4528E+01 1.0655E+00 82.100 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.4528E+01 1.0655E+00 82.400 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.4528E+01 1.0655E+00 96.000 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.4528E+01 1.0655E+00 168. 000 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.4528E+01 1.0655E+00 720.000 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.4528E+01 1.0655E+00 792.000 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.4528E+01 1.0655E+00 Worst Two-Hour Doses Note: All of the dose locations are shown below but the worst two-hour dose is only meaningful for the EAB
CALCULATION NOC- 101-900-EOOO-083 l REV.No. 2 l PAGE NO. 163 dose location. Please disregard the two-hour worst doses for the other dose locations Exclusion Area Boundary Time Whole Body Thyroid TEDE (hr) (rem) (rem) (rem) 72.0 4.8443E-01 1.3147E+02 4.4939E+00 Low Population Zone Time Whole Body Thyroid TEDE (hr) (rem) (rem) (rem) 72.0 8.4776E-02 2.3008E+01 7.8643E-01 Control Room Time Whole Body Thyroid TEDE (hr) (rem) (rem) (rem) 72.0 1.2230E-02 3.4527E+01 1.0652E+O0
I CALCULATION NOC-I 101-900-EOOO-083 I REV. No. 2 TPAGE NO. 164 Appendix J RADTRAD File OH.psf FHA Occurring In Reactor Building With Hatch Doors Opened CR Recirc Flow: 30,800 cfm CR Filtered Intake Flow: 8,000 cfm CR Unfiltered Inleakage: 1,000 cfm CR Exhaust Flow: 9,000 cfm Two Times Iodine & Noble Gas Release Fractions
I CALCULATION NOC-I 101-900-EOOO-083 I REV. No. 2 TPAGE NO. 165 l
- fff#ftf#ft#ftf#ft##ft###############fttff#ff##ftttff##ft######f##f#f#ftft###f#f#fttf##f###
RADTRAD Version 3.02 run on 7/07/2005 at 7:53:39
- fff#######ftf#####################tf###ftttttttftt#f#ftt################ft#f#ft##t########
File information
- fft###############t#######f##ft###############t#######tf###t##f################
Plant file name = C:\Program Files\U S Nuclear Regulatory Commission\Radtrad\OH.psf Inventory file name = c:\program files\u s nuclear regulatory commission\radtrad\defaults\fharb_def_a.nif Scenario file name = C:\Program Files\U S Nuclear Regulatory Commission\Radtrad\OH.psf Release file name = c:\program files\u s nuclear regulatory commission\radtrad\defaults\fha update 6-9-05.rft Dose conversion file name = c:\program files\u s nuclear regulatory commission\radtrad\defaults\fgrll&12.inp
- t #### f#f#### # #t #t ###t## #t #t f####
- t # # #t #t ##f #t #t # # # #
- #f #t # ##t #t #t # # # #
ff##### ##f## ####tf # ft # # ft##### #t #t #
- # # ## #f #f# # #t #
- t #tf#t # #t f ft # # #
- t ##f## #t #t ft #t #t ### #
Radtrad 3.02 1/5/2000 TMI-1 FHAIC With Hatch Doors Opened, AST Analysis, CR Charcoal Filter Efficiency =
75%., CR Recirc = 30,800 cfm, CR Intake = 8,000 cfm Nuclide Inventory File:
c:\program files\u s nuclear regulatory commission\radtrad\defaults\fharbdefa.nif Plant Power Level:
2.6190E+03 Compartments:
3 Compartment 1:
Containment 3
2.1600E+06 0
0 0
0 0
Compartment 2:
Environment 2
0.OOOOE+00 0
0 0
0 0
Compartment 3:
Control Room 1
2.5000E+05 0
0 1
0
CALCULATION NOC-I 101-900-EOOO-083 I REV. No. 2 l PAGE NO. 166 I 0
Pathways:
4 Pathway 1:
Containment to Environment 1
2 2
Pathway 2:
Control Room Air Intake 2
3 2
Pathway 3:
Control Room Unfiltered Inleakage 2
3 2
Pathway 4:
Control Room Exhaust to Environment 3
2 2
End of Plant Model File Scenario Description Name:
Plant Model Filename:
Source Term:
1 1 1.0000E+00 c:\program files\u s nuclear regulatory commission\radtrad\defaults\fgrll&12.inp c:\program files\u s nuclear regulatory commission\radtrad\defaults\fha update 6 05.rft 7.2000E+01 0
O.OOOOE+00 5.7000E-01 4.3000E-01 1.0000E+00 Overlying Pool:
0 o.OOOOE+00 0
0 0
0 Compartments:
3 Compartment 1:
0 1
0 0
0 0
0 0
0 Compartment 2:
0 1
0 0
0 0
0 0
0 Compartment 3:
1
CALCULATION NOC-I 101-900-EOOO-083 I REV. No. 2 1 PAGE NO. 167 1
0 0
0 0
1 3.0800E+04 3
7.2000E+01 O.OOOOE+00 O.OOOOE+00 0.OOOOE+00 7.2500E+01 9.9000E+01 7.5000E+01 7.5000E+01 7.9200E+02 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 0
0 Pathways:
4 Pathway 1:
0 0
0 0
0 1
3 7.2000E+01 1.6580E+05 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 7.4000E+01 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 7.9200E+02 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 0
0 0
0 0
0 Pathway 2:
0 0
0 0
0 1
3 7.2000E+01 4.0000E+03 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 7.2500E+01 8.OOOOE+03 9.9000E+01 7.5000E+01 7.5000E+01 7.9200E+02 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 0
0 0
0 0
0 Pathway 3:
0 0
0 0
0 1
2 7.2000E+01 1.OOOOE+03 0.OOOOE+00 O.OOOOE+00 O.OOOOE+00 7.9200E+02 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 0
0 0
0 0
0 Pathway 4:
0 0
I CALCULATION NOC-I 101-900-EOOO-083 I REV. No. 2 1 PAGE NO. 168 0
0 0
1 3
7.2000E+01 5.OOOOE+03 O.OOOOE+00 0.OOOOE+00 O.OOOOE+00 7.2500E+01 9.0000E+03 1.0000E+02 1.OOOOE+02 1.OOOOE+02 7.9200E+02 O.OOOOE+00 O.OOOOE+00 0.0000E4-00 O.OOOOE+00 0
0 0
0 0
0 Dose Locations:
3 Location 1:
Exclusion Area Boundary 2
1 2
7.2000E+01 8.OOOOE-04 7.2000E+02 O.OOOOE+00 1
2 7.2000E+01 3.5000E-04 7.2000E+02 O.OOOOE+00 0
Location 2:
Low Population Zone 2
1 6
7.2000E+01 1.4000E-04 7.4000E+01 6.OOOOE-05 8.OOOOE+01 3.9000E-05 9.6000E+01 1.6000E-05 1.6800E+02 4.OOOOE-06 7.9200E+02 O.OOOOE+00 1
4 7.2000E+01 3.5000E-04 8.OOOOE+01 1.8000E-04 9.6000E+01 2.30OOE-04 7.9200E+02 O.OOOOE+00 0
Location 3:
Control Room 3
0 1
2 7.2000E+01 3.5000E-04 7.9200E+02 O.OOOOE+00 1
4 7.2000E+01 1.OOOOE+00 9.6000E+01 6.OOOOE-01 1.6800E+02 4.OOOOE-01 7.9200E+02 O.OOOOE+00 Effective Volume Location:
1 6
7.2000E+01 5.3400E-04 7.4000E+01 3.1000E-04 8.OOOOE+01 1.3600E-04 9.6000E+01 9.7000E-05 1.6800E+02 6.0200E-05
CALCULATION NOC-101I-900-EOOO-083 l REV.No. 2 PAGE NO. 169 l 7.9200E+02 O.OOOOE+00 Simulation Parameters:
6 7.2000E+O1 1.OOOOE-O1 7.4000E+01 5.OOOOE-01 8.OOOOE+O1 1.OOOOE+OO 9.6000E+01 2.OOOOE+00 1.6800E+02 4.OOOOE+O0 7.9200E+02 O.OOOOE+OO Output Filename:
C:\Program Files\U S Nuclear Regulatory Commission\Radtrad\OH.ol 1
1 1
0 End of Scenario File RADTRAD Version 3.02 run on 7/07/2005 at 7:53:39 Plant Description Number of Nuclides 60 Inventory Power = 1.OOOOE+O0 MWth Plant Power Level = 2.6190E+03 MWth Number of compartments = 3 Compartment information Compartment number 1 (Source term fraction = 1.OOOOE+00 Name: Containment Compartment volume = 2.1600E+06 (Cubic feet)
Pathways into and out of compartment 1 Pathway to compartment number 2: Containment to Environment Compartment number 2 Name: Environment Pathways into and out of compartment 2 Pathway to compartment number 3: Control Room Air Intake Pathway to compartment number 3: Control Room Unfiltered Inleakage Pathway from compartment number 1: Containment to Environment Pathway from compartment number 3: Control Room Exhaust to Environment Compartment number 3 Name: Control Room Compartment volume = 2.5000E+05 (Cubic feet)
Removal devices within compartment:
Filter(s)
Pathways into and out of compartment 3 Pathway to compartment number 2: Control Room Exhaust to Environment Pathway from compartment number 2: Control Room Air Intake Pathway from compartment number 2: Control Room Unfiltered Inleakage Total number of pathways = 4 RADTRAD Version 3.02 run on 7/07/2005 at 7:53:39
I CALCULATION NOC-I 101-900-EOOO-U83 I REV.No. 2 It PAGE NO. 170 I PAGE NO. 170 I I CALCULATION NOC-1 IW-900-.EOOO-083 I REV. No. 2 Scenario Description Time between shutdown and first release = 7.2000E+01 (Hours)
Radioactive Decay is enabled RELEASENAME = RG-1.183, Tables 3 Section 3.2 Release Fractions and Timings GAP EARLY IN-VESSEL 0.0036 hrs 0.0000 hrs NOBLES 1.0000E-01 0.OOOOE+00 IODINE 1.0000E-01 0.0000E+00 CESIUM 0.OOOOE+00 0.OOOOE+00 TELLURIUM 0.0000E+00 0.OOOOE+00 STRONTIUM O.0000E+00 0.OOOOE+00 BARIUM O.0000E+00 0.OOOOE+00 RUTHENIUM 0.0000E+00 0.OOOOE+00 CERIUM 0.OOOOE+00 0.OOOOE+00 LANTHANUM O.0000E+00 0.OOOOE+00 Iodine fractions Aerosol 0.0000E+00 Elemental 5.7000E-01 Organic 4.3000E-01 COMPARTMENT DATA Compartment number 1: Containment Compartment number 2: Environment Compartment number 3: Control Room Compartment Filter Data Time (hr) Flow Rate Filter Efficiencies (%)
(cfm) Aerosol Elemental Organic 7.2000E+01 3.0800E+04 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 7.2500E+01 3.0800E+04 9.9000E+01 7.5000E+01 7.5000E+01 7.9200E+02 3.0800E+04 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 PATHWAY DATA Pathway number 1: Containment to Environment Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)
(cfm) Aerosol Elemental Organic 7.2000E+01 1.6580E+05 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 7.4000E+01 0.OOOOE+00 O.OOOOE+00 0.OOOOE+00 0.OOOOE+00 7.9200E+02 0.OOOOE+00 0.OOOOE+00 0.0000E+00 0.OOOOE+00 Pathway number 2: Control Room Air Intake Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)
(cfm) Aerosol Elemental Organic 7.2000E+01 4.OOOOE+03 0.OOOOE+00 0.OOOOE+00 0.0000E+00 7.2500E+01 8.0000E+03 9.9000E+01 7.5000E+01 7.5000E+01 7.9200E+02 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Pathway number 3: Control Room Unfiltered Inleakage Pathway Filter: Removal Data
CALCULATION NOC-1 I10-900-EOOO-083 _ REV. No. 2 I PAGE NO. 171 Time (hr) Flow Rate Filter Efficiencies C%)
(cfm) Aerosol Elemental Organic 7.2000E+01 1.OOOOE+03 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 7.9200E+02 0.000OE+00 0.OOOOE+00 O.OOOOE+00 0.OOOOE+00 Pathway number 4: Control Room Exhaust to Environment Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)
(cfm) Aerosol Elemental Organic 7.2000E+01 5.OOOOE+03 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 7.2500E+01 9.OOOOE+03 1.OOOOE+02 1.OOOOE+02 1.0000E+02 7.9200E+02 O.OOOOE+00 0.OOOOE+00 0.OOOOE+00 O.OOOOE+00 LOCATION DATA Location Exclusion Area Boundary is in compartment 2 Location X/Q Data Time (hr) X/Q (s
- m^-3) 7.2000E+01 8.OOOOE-04 7.2000E+02 0.OOOOE+00 Location Breathing Rate Data Time (hr) Breathing Rate (m^3
- sec^-1) 7.200OE+01 3.5000E-04 7.2000E+02 O.OOOOE+00 Location Low Popu 1Fa Ltion Zone is in compartment 2 Location X/Q Data Time (hr) X/Q (s
- m^-3) 7.2000E+01 1.4000E-04 7.4000E+01 6.OOOOE-05 8.OOOOE+01 3.9000E-05 9.6000E+01 1.6000E-05 1.6800E+02 4.OOOOE-06 7.9200E+02 0.OOOOE+00 Location Breathing Ral te DaLta Time (hr) BrEeathiing Rate (m^3
- sec 3c-1) 7.2000E+01 3.5000E-04 8.OOOOE+01 1.8000E-04 9.6000E+01 2.3000E-04 7.9200E+02 O.OOOOE+00 Location Control Room is in compartment Location X/Q Data Time (hr) X/Q (s
- m^-3) 7.2000E+01 5.3400E-04 7.4000E+01 3.10OOE-04 8.OOOOE+01 1.3600E-04 9.6000E+01 9.7000E-05 1.6800E+02 6.0200E-05 7.9200E+02 0.OOOOE+00 Location Breathing Rate Data Time (hr) Breathing Rate (mA3
- sec^-1) 7.2000E+01 3.5000E-04 7.9200E+02 0.OOOOE+00 Location Occupancy Factor Data Time (hr) Occupancy Factor 7.2000E+01 1.OOOOE+00 9.6000E+01 6.OOOOE-01 1.6800E+02 4.OOOOE-01 7.9200E+02 0.OOOOE+00
CALCULATION NOC-I 101-900-EOOO-083 I REV. No. 2 l PAGE NO. 172 USER SPECIFIED TIME STEP DATA - SUPPLEMENTAL TIME STEPS Time Time step 0.0000E+00 1.OOOOE-01 2.0000E+00 5.0000E-01 8.0000E+00 1.OOOOE+00 2.4000E+01 2.0000E+00 9.6000E+01 4.OOOOE+00 7.2000E+02 0.0000E+00 RADTRAD Version 3.02 run on 7/07/2005 at 7:53:39
- if#if if if if if if ififififif I ifif .if if I if if if if if #
I ## if if ##if if #f #
if # if if 1 if if if if ifififif ifif## if if Dose, Detailed model and Detailed Inventory Output Exclusion Area Boundary Doses:
Time (h) = 72.0036 Whole Body Thyroid TEDE Delta dose (rem) 3.9946E-03 1.0846E+00 3.7073E-02 Accumulated dose (rem) 3.9946E-03 1.0846E+00 3.7073E-02 Low Population Zone Doses:
Time (h) = 72.0036 Whole Body Thyroid TEDE Delta dose (rem) 6.9906E-04 1.8981E-01 6.4878E-03 Accumulated dose (rem) 6.9906E-04 1.8981E-01 6.4878E-03 Control Room Doses:
Time (h) = 72.0036 Whole Body Thyroid TEDE Delta dose (rem) 2.5519E-07 1.2176E-03 3.7387E-05 Accumulated dose (rem) 2.5519E-07 1.2176E-03 3.7387E-05 Control Room Compartment Nuclide Inventory:
Time (h) = 72.0036 Ci kg Atoms Bq Kr-85 2.0817E-02 5.3058E-08 3.7591E+17 7.7022E+08 Kr-85m 3.3667E-06 4.0910E-16 2.8984E+09 1.2457E+05 Kr-88 1.5065E-08 1.2014E-18 8.2219E+06 5.5741E+02 I-131 4.3989E-03 3.5482E-11 1. 6311E+14 1.6276E+08 I-133 6.7593E-04 5.9669E-13 2.7017E+12 2.5009E+07 I-135 3.6515E-06 1.0398E-15 4.6383E+09 1.3511E+05 Xe-133 1.0054E+00 5.3711E-09 2.4320E+16 3.7199E+10 Xe-135 2.2653E-03 8.8705E-13 3.9570E+12 8.3816E+07 Control Room Transport Group Inventory:
Overlying Time (h) = 72.0036 Atmosphere Sump Pool Noble gases (atoms) 4.0024E+17 0.OOOOE+00 0.0000E+00 Elemental I (atoms) 9.4518E+13 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) 7.1303E+13 0.OOOOE+00 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00
I CALCULATION NOC-I 101-900-EOOO-083 l REV. No. 2 I PAGE NO. 173 Deposition Recirculating Time (h) = 72.0036 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.0000E+00 O.OOOOE+00 Organic I (atoms) 0.OOOOE+00 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 O.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 72.0036 Filter Noble gases (atoms) O.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 72.0036 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 72.0036 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 72.5000 Whole Body Thyroid TEDE Delta dose (rem) 4.3151E-01 1.1720E+02 4.0058E+00 Accumulated dose (rem) 4.3551E-01 1.1829E+02 4.0429E+00 Low Population Zone Doses:
Time (h) = 72.5000 Whole Body Thyroid TEDE Delta dose (rem) 7.5515E-02 2. 0510E+01 7.0101E-01 Accumulated dose (rem) 7.6214E-02 2.0700E+01 7.0750E-01 Control Room Doses:
Time (h) = 72.5000 Whole Body Thyroid TEDE Delta dose (rem) 5.2760E-03 2.5188E+01 7.7343E-01 Accumulated dose (rem) 5.2763E-03 2.5190E+01 7.7347E-01 Control Room Compartment Nuclide Inventory:
Time (h) 72.5000 Ci kg Atoms Bq Kr-85 1.5368E+00 3.9169E-06 2.7751E+19 5.6860E+10 Kr-85m 2.3017E-04 2.7968E-14 1.9815E+11 8.5162E+06 Kr-88 9.8526E-07 7.8574E-17 5.3771E+08 3.6455E+04 I-131 3.2416E-01 2.6147E-09 1.2020E+16 1.1994E+10 I-133 4.9081E-02 4.3327E-11 1.9618E+14 1.8160E+09 I-135 2.5589E-04 7.2866E-14 3.2504E+11 9.4681E+06 Xe-133 7.4017E+01 3.9543E-07 1.7905E+18 2.7386E+12 Xe-135 1.6102E-01 6.3053E-11 2.8127E+14 5.9577E+09 Control Room Transport Group Inventory:
Overlying
CALCULATION NOC-1 101 -900-EOOO-083 I REV. No. 2 1 PAGE NO. 174 Time (h) = 72.5000 Atmosphere Sump Pool Noble gases (atoms) 2.9547E+19 0.OOOOE+00 0.0000E+00 Elemental I (atoms) 6.9776E+15 0.OOOOE+00 0.0000E+00 Organic I (atoms) 5.2638E+15 0.0000E+00 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 0.0000E+00 Deposition Recirculating Time (h) = 72.5000 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 0.0000E+00 Elemental I (atoms) 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) 0.0000E+00 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 72.5000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.0000E+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 72.5000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 72.5000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 74.0000 Whole Body Thyroid TEDE Delta dose (rem) 4.9006E-02 1.3212E+01 4.5191E-01 Accumulated dose (rem) 4.8451E-01 1.3150E+02 4.4948E+00 Low Population Zone Doses:
Time (h) = 74.0000 Whole Body Thyroid TEDE Delta dose (rem) 8.5760E-03 2.3121E+00 7.9084E-02 Accumulated dose (rem) 8.4790E-02 2.3012E+01 7.8659E-01 Control Room Doses:
Time (h) = 74.0000 Whole Body Thyroid TEDE Delta dose (rem) 7.3326E-03 9.4968E+00 2.9695E-01 Accumulated dose (rem) 1.2609E-02 3.4686E+01 1.0704E+00 Control Room Compartment Nuclide Inventory:
Time (h) = 74.0000 Ci kg Atoms Bq Kr-85 9.3790E-02 2.3906E-07 1.6937E+18 3.4702E+09 Kr-85m 1.1138E-05 1.3534E-15 9.5889E+09 4.1211E+05 Kr-88 4.1698E-08 3.3254E-18 2.2757E+07 1.5428E+03 I-131 5.0302E-05 4.0575E-13 1.8652E+12 1.8612E+06 I-133 7.2840E-06 6.4301E-15 2.9115E+10 2.6951E+05 I-135 3.4113E-08 9.7136E-18 4.3331E+07 1.2622E+03 Xe-133 4.4803E+00 2.3935E-08 1.0838E+17 1.6577E+11
I CALCULATION NOC-1101-900-EOOO-083 I REV. No. 2 1 PAGE NO. 175 Xe-135 8.7652E-03 3.4323E-12 1.5311E+13 3.2431E+08 Control Room Transport Group Inventory:
Overlying Time (h) = 74.0000 Atmosphere Sump Pool Noble gases (atoms) 1.8033E+18 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 1.0886E+12 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) 8.2124E+11 0.OOOOE+00 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Deposition Recirculating Time (h) = 74.0000 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 5.4890E+15 Organic I (atoms) 0.OOOOE+00 4.1409E+15 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 74.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 5.0636E+20 Organic I (atoms) 3.8199E+20 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 74.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 74.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 2.1386E+15 Organic I (atoms) 1.6133E+15 Aerosols (kg) 0.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 80.0000 Whole Body Thyroid TEDE Delta dose (rem) 2.1001E-05 0.OOOOE+00 2.1001E-05 Accumulated dose (rem) 4.8453E-01 1.3150E+02 4.4948E+00 Low Population Zone Doses:
Time (h) = 80.0000 Whole Body Thyroid TEDE Delta dose (rem) 1.5751E-06 0.OOOOE+00 1.5751E-06 Accumulated dose (rem) 8.4791E-02 2.3012E+01 7.8659E-01 Control Room Doses:
Time (h) = 80.0000 Whole Body Thyroid TEDE Delta dose (rem) 3.5310E-04 1.3483E-03 3.9422E-04 Accumulated dose (rem) 1.2962E-02 3.4688E+01 1.0708E+00 Control Room Compartment Nuclide Inventory:
Time (h) = 80.0000 Ci kg Atoms Bq Kr-85 2.2444E-07 5.7205E-13 4.0529E+12 8.3041E+03 Xe-133 1.0373E-05 5.5417E-14 2.5093E+11 3.8381E+05
CALCULATION NOC-I 10I-900-EOOO-083 REV. No. 2 l PAGE NO. 176 l Xe-135 1.3274E-08 5.1981E-18 2.3188E+07 4.9116E+02 Control Room Transport Group Inventory:
Overlying Time (h) = 80.0000 Atmosphere Sump Pool Noble gases (atoms) 4.3154E+12 o.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 9.1632E-09 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) 6.9126E-09 0.OOOOE+00 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Deposition Recirculating Time (h) = 80.0000 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 5.4898E+15 Organic I (atoms) 0.OOOOE+00 4.1414E+15 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 80.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 5.0636E+20 Organic I (atoms) 3.8199E+20 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 80.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 80.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 2.1389E+15 Organic I (atoms) 1.6135E+15 Aerosols (kg) 0.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 96.0000 Whole Body Thyroid TEDE Delta dose (rem) 4.8350E-11 0.OOOOE+00 4.8350E-11 Accumulated dose (rem) 4.8453E-01 1.3150E+02 4.4948E+00 Low Population Zone Doses:
Time (h) = 96.0000 Whole Body Thyroid TEDE Delta dose (rem) 2.3571E-12 0.OOOOE+00 2.3571E-12 Accumulated dose (rem) 8.4791E-02 2.3012E+01 7.8659E-01 Control Room Doses:
Time (h) = 96.0000 Whole Body Thyroid TEDE Delta dose (rem) 8.1291E-10 1.1065E-23 8.1291E-10 Accumulated dose (rem) 1.2962E-02 3.4688E+01 1.0708E+00 Control Room Compartment Nuclide Inventory:
Time (h) = 96.0000 Ci kg Atoms Bq Control Room Transport Group Inventory:
CALCULATION NOC-1 101-900-EOOO-083 7 REV. No. 2 I PAGE NO. 177 Overlying Time (h) = 96.0000 Atmosphere Sump Pool Noble gases (atoms) 4.3099E-03 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 2.6761E-62 0.0000E+00 0.OOOOE+00 Organic I (atoms) 2.0188E-62 0.OOOOE+00 0.OOOOE+00 Aerosols (kg) 0.0000E+00 0.0000E+00 0.0000E+00 Deposition Recirculating Time (h) = 96.0000 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 5.4898E+15 Organic I (atoms) 0.OOOOE+00 4.1414E+15 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 5.0636E+20 Organic I (atoms) 3.8199E+20 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.0000E+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 2.1389E+15 Organic I (atoms) 1.6135E+15 Aerosols (kg) 0.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 168.0000 Whole Body Thyroid TEDE Delta dose (rem) 4.4032E-26 0.OOOOE+00 4.4032E-26 Accumulated dose (rem) 4.8453E-01 1.3150E+02 4.4948E+00 Low Population Zone Doses:
Time (h) = 168.0000 Whole Body Thyroid TEDE Delta dose (rem) 8.8064E-28 0.OOOOE+00 8.8064E-28 Accumulated dose (rem) 8.4791E-02 2.3012E+01 7.8659E-01 Control Room Doses:
Time (h) = 168.0000 Whole Body Thyroid TEDE Delta dose (rem) 9.8113E-25 1.3348E-76 9.8113E-25 Accumulated dose (rem) 1.2962E-02 3.4688E+01 1.0708E+00 Control Room Compartment Nuclide Inventory:
Time (h) = 168.0000 Ci kg Atoms Bq Control Room Transport Group Inventory:
Overlying Time (h) = 168.0000 Atmosphere Sump Pool
CALCULATION NOC-I 101-900-EOOO-083 l-REV. No. 2 1 PAGE NO. 178 Noble gases (atoms) 1.3206E-70 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 3.3015-303 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) 2.4906-303 0.0000E+00 0.0000E+00 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Deposition Recirculating Time (h) = 168.0000 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 5.4898E+15 Organic I (atoms) 0.OOOOE+00 4.1414E+15 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 168.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 5.0636E+20 Organic I (atoms) 3.8199E+20 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 168.0000 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 168.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 2.1389E+15 Organic I (atoms) 1.6135E+15 Aerosols (kg) 0.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 720.0000 Whole Body Thyroid TEDE Delta dose (rem) 9.0557E-94 0.OOOOE+00 9.0557E-94 Accumulated dose (rem) 4.8453E-01 1.3150E+02 4.4948E+00 Low Population Zone Doses:
Time (h) = 720.0000 Whole Body Thyroid TEDE Delta dose (rem) 4.5279E-96 0.OOOOE+00 4.5279E-96 Accumulated dose (rem) 8.4791E-02 2.3012E+01 7.8659E-01 Control Room Doses:
Time (h) = 720.0000 Whole Body Thyroid TEDE Delta dose (rem) 2.6210E-92 1.6768-317 2.6210E-92 Accumulated dose (rem) 1.2962E-02 3.4688E+01 1.0708E+00 Control Room Compartment Nuclide Inventory:
Time (h) = 720.0000 Ci kg Atoms Bq Control Room Transport Group Inventory:
Overlying Time (h) = 720.0000 Atmosphere Sump Pool Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00
I CALCULATION NOC-I 101-900-EOOO-083 l REV. No. 2 I PAGE NO. 179 Aerosols (kg) 0.OOOOE+00 0.0000E+00 0.OOOOE+00 Deposition Recirculating Time (h) = 720.0000 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 5.4898E+15 Organic I (atoms) 0.OOOOE+00 4.1414E+15 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 5.0636E+20 Organic I (atoms) 3.8199E+20 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 2.1389E+15 Organic I (atoms) 1.6135E+15 Aerosols (kg) 0.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 792.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.OOOOE+00 0.OOOOE+00 Accumulated dose (rem) 4.8453E-01 1.3150E+02 4.4948E+00 Low Population Zone Doses:
Time (h) = 792.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Accumulated dose (rem) 8.4791E-02 2.3012E+01 7.8659E-01 Control Room Doses:
Time (h) = 792.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Accumulated dose (rem) 1.2962E-02 3.4688E+01 1.0708E+00 Control Room Compartment Nuclide Inventory:
Time (h) = 792.0000 Ci kg Atoms Bq Control Room Transport Group Inventory:
Overlying Time (h) = 792.0000 Atmosphere Sump Pool Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.0000E+00 0.OOOOE+00 0.0000E+00 Organic I (atoms) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Deposition Recirculating
CALCULATION NOC-1 101-900-EOOO-083 I REV. No. 2 1 PAGE NO. 180 Time (h) = 792.0000 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 5.4898E+15 Organic I (atoms) 0.OOOOE+00 4.1414E+15 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 792.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 5.0636E+20 Organic I (atoms) 3.8199E+20 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 792.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 792.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 2.1389E+15 Organic I (atoms) 1.6135E+15 Aerosols (kg) 0.OOOOE+00 334 I-131 Summary Containment Environment Control Room Time (hr) I-131 (Curies) I-131 (Curies) 1-131 (Curies) 72.001 6.5355E+01 8.3646E-02 1.0538E-04 72.004 4.2054E+02 3.4959E+00 4.3989E-03 72.400 6.7659E+01 3.5615E+02 3.3229E-01 72.500 4.2673E+01 3.8115E+02 3.2416E-01
- 72. 800 1.0706E+01 4.1309E+02 3.9386E-02 73.100 2.6861E+00 4.2110E+02 5.7276E-03 73.400 6.7390E-01 4.2311E+02 1.0256E-03 73.700 1.6907E-01 4.2362E+02 2.1658E-04 74.000 4.2419E-02 4.2374E+02 5.0302E-05 74.300 4.2373E-02 4.2374E+02 4.9817E-06
- 74. 600 4.2328E-02 4.2374E+02 4.9337E-07
- 74. 900 4.2282E-02 4.2374E+02 4.8861E-08 75.200 4.2236E-02 4.2374E+02 4.8389E-09
- 75. 500 4.2191E-02 4.2374E+02 4.7923E-10
- 75. 800 4.2146E-02 4.2374E+02 4.7460E-11
- 76. 100 4.2100E-02 4.2374E+02 4.7003E-12 76.400 4.2055E-02 4.2374E+02 4.6549E-13 76.700 4.2010E-02 4.2374E+02 4.6100E-14
- 77. 000 4.1964E-02 4.2374E+02 4.5656E-15 77.300 4.1919E-02 4.2374E+02 4.5215E-16 77.600 4.1874E-02 4.2374E+02 4.4779E-17
- 77. 900 4.1829E-02 4.2374E+02 4.4347E-18 78.200 4.1784E-02 4.2374E+02 4.3919E-19
- 78. 500 4.1739E-02 4.2374E+02 4.3496E-20
- 78. 800 4.1694E-02 4.2374E+02 4.3076E-21 79.100 4.1649E-02 4.2374E+02 4.2661E-22
- 79. 400 4.1604E-02 4.2374E+02 4.2249E-23
I CALCULATION NOC-1101-900-E000-083 I REV. No. 2 1 PAGE NO. 181 79.700 4.1559E-02 4.2374E+02 4.1842E-24 80.000 4.1514E-02 4.2374E+02 4.1438E-25 80.300 4.1470E-02 4.2374E+02 4.1038E-26 80.600 4.1425E-02 4.2374E+02 4.0642E-27 80.900 4.1380E-02 4.2374E+02 4.0250E-28 81.200 4.1336E-02 4.2374E+02 3.9862E-29 81.500 4.1291E-02 4.2374E+02 3.9478E-30 81.800 4.1247E-02 4.2374E+02 3.9097E-31 82.100 4.1202E-02 4.2374E+02 3.8720E-32 82.400 4.1158E-02 4.2374E+02 3.8346E-33 96.000 3.9196E-02 4.2374E+02 1.1426E-78 168. 000 3.0263E-02 4.2374E+02 1.0884-319 720.000 4.1664E-03 4.2374E+02 O.OOOOE+00 792.000 3.2169E-03 4.2374E+02 O.OOOOE+00 Cumulative Dose Summary Exclusion Area Bounda Low Population Zone Contro:1 Room Time Thyroid TEDE Thyroid TEDE Thyroid TEDE (hr) (rem) (rem) (rem) (rem) (rem) (rem) 72.001 2.5952E-02 8.8702E-04 4.5415E-03 1.5523E-0' 5.7730E-06 1.7727E-07 I
72.004 1.0846E+00 3.7073E-02 1.8981E-01 6.4878E-O- 1.2176E-03 3.7387E-05 72.400 1.1053E+02 3.7778E+00 1.9343E+01 6.6111E-0:L 1. 8717E+01 5.7473E-01 72.500 1.1829E+02 4.0429E+00 2.0700E+01 7.0750E-0:L 2.5190E+01 7.7347E-01 72.800 1.2819E+02 4.3816E+00 2.2434E+01 7.6679E-0:L 3.3431E+01 1.0281E+00 73.100 1.3068E+02 4.4667E+00 2.2869E+01 7.8167E-0:L 3.4484E+01 1.0622E+00 73.400 1.3130E+02 4.4880E+00 2.2978E+01 7.8541E-0:L 3.4648E+01 1.0683E+00 73.700 1.3146E+02 4.4934E+00 2.3005E+01 7.8635E-0:L 3.4680E+01 1.0699E+00 74.000 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-0:L 3.4686E+01 1.0704E+00 74.300 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-0:L 3.4688E+01 1.0706E+00 74.600 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-0:L 3.4688E+01 1.0707E+O0 74.900 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-0:L 3.4688E+01 1.0708E+00 75.200 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-0:L 3.4688E+01 1.0708E+00 75.500 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-0: 3.4688E+01 1.0708E+00 L
75.800 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-0:L 3.4688E+01 1.0708E+00 76.100 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-O0 3.4688E+01 1.0708E+00 L
76.400 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-O0 3.4688E+01 1.0708E+00 76.700 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-0O 3.4688E+01 1.0708E+00 77.000 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-O0 3.4688E+01 1.0708E+00 77.300 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-O0 3.4688E+01 1.0708E+00 77.600 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-O0 3.4688E+01 1.0708E+00 77.900 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-0: 3.4688E+01 1.0708E+00 78.200 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-0: 3.4688E+01 1.0708E+00 78.500 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-01 3.4688E+01 1.0708E+00 78.800 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-0O 3.4688E+01 1.0708E+00 79.100 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-0O 3.4688E+01 1.0708E+00 79.400 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-0O 3.4688E+01 1.0708E+00 79.700 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-0O 3.4688E+01 1.0708E+00 80.000 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-0O 3.4688E+01 1.0708E+00 80.300 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-0O 3.4688E+01 1.0708E+00 80.600 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-Ol 3.4688E+01 1.0708E+00 80.900 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-Ol 3.4688E+01 1.0708E+00 81.200 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-Ol 3.4688E+01 1.0708E+00 81.500 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-Ol 3.4688E+01 1.0708E+00 81.800 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-0O 3.4688E+01 1.0708E+00 82.100 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-0O 3.4688E+01 1.0708E+00 82.400 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-0O 3 .4688E+01 1.0708E+00
- 96. 000 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-0O 3.4688E+01 1.0708E+00 168.000 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-03 3.4688E+01 1.0708E+00 720.000 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-03 3.4688E+01 1.0708E+00 792.000 1.3150E+02 4.4948E+00 2.3012E+01 7.8659E-0O 3.4688E+01 1.0708E+00 Worst Two-Hour Doses Note: All of the dose locations are shown below but the worst two-hour dose is only meaningful for the EAB
CALCULATION NOC-101I-900-EOOO-083 REV. No. 2 PAGE NO. 182 dose location. Please disregard the two-hour worst doses for the other dose locations Exclusion Area Boundary Time Whole Body Thyroid TEDE (hr) (rem) (rem) (rem) 72.0 4.8442E-01 1.3147E+02 4.4939E+00 Low Population Zone Time Whole Body Thyroid TEDE (hr) (rem) (rem) (rem) 72.0 8.4773E-02 2.3008E+01 7.8643E-01 Control Room Time Whole Body Thyroid TEDE (hr) (rem) (rem) (rem) 72.0 1.2609E-02 3.4686E+01 1.0704E+00
CALCULATION NOC-I 101-900-EOOO-083 l REV. No. 2 l PAGE NO. 183 l Appendix K RADTRAD File OI.psf FHA Occurring In Reactor Building With Hatch Doors Opened CR Recirc Flow: 30,800 cfm CR Filtered Intake Flow: 7,200 cfm CR Unfiltered Inleakage: 1,000 cfm CR Exhaust Flow: 8,200 cfm Two Times Iodine & Noble Gas Release Fractions
I CALCULATION NOC-I 101 -900-EOOO-083 No. 22 IIPAGE PAGE NO. 184 I CALCULATION NOC-1 1O1-900-EOOO-083 REV. No.
II REV. NO. 184 I RADTRAD Version 3.02 run on 7/07/2005 at 7:53:39 File information
- f~ifififf~ifiififif##
Plant file name = C:\Program Files\U S Nuclear Regulatory Commission\Radtrad\0I.psf Inventory file name = c:\program files\u s nuclear regulatory commission\radtrad\defaults\fharbdef_a.nif Scenario file name = C:\Program Files\U S Nuclear Regulatory Commission\Radtrad\0I.psf Release file name = c:\program files\u s nuclear regulatory commission\radtrad\defaults\fha update 6-9-05.rft Dose conversion file name = c:\program files\u s nuclear regulatory commission\radtrad\defaults\fgrll&12.inp
- ifififif ifif## if#### if if if ###if# if if
- # if if if ifif if if if if #
if if if ifif if if # # if if ififif if #if## if### if if if if##if# if if if ifif if if ifif if if if if # #if if # if if if# ifif Radtrad 3.02 1/5/2000 TMI-1 FHAIC With Hatch Doors Opened, AST Analysis, CR Charcoal Filter Efficiency =
75%., CR Recirc = 30,800 cfm, CR Intake = 7,200 cfm Nuclide Inventory File:
c:\program files\u s nuclear regulatory commission\radtrad\defaults\fharb_def_a.nif Plant Power Level:
2.6190E+03 Compartments:
3 Compartment 1:
Containment 3
2.1600E+06 0
0 0
0 0
Compartment 2:
Environment 2
0.OOOOE+00 0
0 0
0 0
Compartment 3:
Control Room 1
2.5000E+05 0
0 1
0
CALCULATION NOC-I 10I-900-EOOO-083 REV. No. 2 I PAGE NO. 185 0
PathwayE 4
Pathway 1:
Containnnent to Environment 1
2 2
Pathway 2:
Control Room Air Intake 2
3 2
Pathway 3:
Control Room Unfiltered Inleakage 2
3 2
Pathway 4:
Control Room Exhaust to Environment 3
2 2
End of Plant Model File Scenario Description Name:
Plant Model Filename:
Source Term:
1 1 1.0000E+00 c:\program files\u s nuclear regulatory commission\radtrad\defaults\fgrll&12.inp c:\program files\u s nuclear regulatory commission\radtrad\defaults\fha update 6 05.rft 7.2000E+01 0
0.0000E+00 5.7000E-01 4.3000E-01 1.OOOOE+00 Overlying Pool:
0 o.OOOOE+00 0
0 0
0 Compartments:
3 Compartment 1:
0 1
0 0
0 0
0 0
0 Compartment 2:
0 1
0 0
0 0
0 0
0 Compartment 3:
1
I CALCULATION NOC-1101-900-EOOO-083 I REV. No. 2 TPAGE NO. 186 1
0 0
0 0
1 3.0800E+04 3
7.2000E+01 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 7.2500E+01 9.9000E+01 7.5000E+01 7.5000E+01 7.9200E+02 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 0
0 Pathways:
4 Pathway 1:
0 0
0 0
0 1
3 7.2000E+01 1.6580E+05 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 7.4000E+01 O.OOOOE+00 O.OOOOE+00 0.OOOOE+00 O.OOOOE+00 7.9200E+02 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 0
0 0
0 0
0 Pathway 2:
0 0
0 0
0 1
3 7.2000E+01 4.OOOOE+03 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 7.2500E+01 7.2000E+03 9.9000E+01 7.5000E+01 7.5000E+01 7.9200E+02 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 0
0 0
0 0
0 Pathway 3:
0 0
0 0
0 1
2 7.2000E+01 1.OOOOE+03 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 7.9200E+02 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 O.OOOOE+00 0
0 0
0 0
0 Pathway 4:
0 0
I CALCULATION NOC-I101-900-EOOO-083 _ REV. No. 2 l PAGE NO. 187 0
0 0
1 3
7.2000E+01 5.OOOOE+03 O.OOOOE+OO 0.OOOOE+00 O.OOOOE+O0 7.2500E+01 8.2000E+03 1.OOOOE+02 1.OOOOE+02 1.OOOOE+02 7.9200E+02 O.OOOOE+O0 O.OOOOE+00 0.OOOOE+00 O.OOOOE+O0 0
0 0
0 0
0 Dose Locations:
3 Location 1:
Exclusion Area Boundary 2
1 2
7.2000E+01 8.OOOOE-04 7.2000E+02 O.OOOOE+00 1
2 7.2000E+01 3.5000E-04 7.2000E+02 O.OOOOE+OO 0
Location 2:
Low Population Zone 2
1 6
7.2000E+01 1.4000E-04 7.4000E+01 6.OOOOE-05 8.OOOOE+01 3.90OOE-05 9.6000E+01 1.6000E-05 1.6800E+02 4.OOOOE-06 7.9200E+02 O.OOOOE+00 1
4 7.2000E+01 3.5000E-04 8.OOOOE+01 1.8000E-04 9.6000E+01 2.3000E-04 7.9200E+02 O.OOOOE+O0 0
Location 3:
Control Room 3
0 1
2 7.2000E+01 3.5000E-04 7.9200E+02 O.OOOOE+OO 1
4 7.2000E+O1 1.OOOOE+OO 9.6000E+01 6.OOOOE-01 1.6800E+02 4.OOOOE-01 7.9200E+02 O.OOOOE+OO Effective Volume Location:
1 6
7.2000E+01 5.340OE-04 7.4000E+01 3.10OOE-04 8.OOOOE+01 1.3600E-04 9.6000E+01 9.7000E-05 1.6800E+02 6.0200E-05
CALCULATION NOC-I 101-900-EOOO-083 l REV. No. 2 _ PAGE NO. 188 l 7.9200E+02 O.OOOOE+00 Simulation Parameters:
6 7.2000E+01 1.OOOOE-0l 7.4000E+01 5.OOOOE-0l 8.OOOOE+01 1.OOOOE+00 9.6000E+01 2.OOOOE+00 1.6800E+02 4.OOOOE+00 7.9200E+02 O.OOOOE+00 Output Filename:
C:\Program Files\U S Nuclear Regulatory Commission\Radtrad\OI.o2 1
1 1
0 0
End of Scenario File RADTRAD Version 3.02 run on 7/07/2005 at 7:53:39 Plant Description Number of Nuclides = 60 Inventory Power = 1.0000E+00 MWth Plant Power Level 2.6190E+03 MWth Number of compartments = 3 Compartment information Compartment number 1 (Source term fraction = 1.OOOOE+00
)
Name: Containment Compartment volume = 2.1600E+06 (Cubic feet)
Pathways into and out of compartment 1 Pathway to compartment number 2: Containment to Environment Compartment number 2 Name: Environment Pathways into and out of compartment 2 Pathway to compartment number 3: Control Room Air Intake Pathway to compartment number 3: Control Room Unfiltered Inleakage Pathway from compartment number 1: Containment to Environment Pathway from compartment number 3: Control Room Exhaust to Environment Compartment number 3 Name: Control Room Compartment volume = 2.5000E+05 (Cubic feet)
Removal devices within compartment:
Filter(s)
Pathways into and out of compartment 3 Pathway to compartment number 2: Control Room Exhaust to Environment Pathway from compartment number 2: Control Room Air Intake Pathway from compartment number 2: Control Room Unfiltered Inleakage Total number of pathways = 4 RADTRAD Version 3.02 run on 7/07/2005 at 7:53:39
I CALCULATION NOC-l 101-900-EOOO-083 I REV. No. 2 @PAGE NO. 189 l Scenario Description Time between shutdown and first release = 7.2000E+01 (Hours)
Radioactive Decay is enabled RELEASE_NAME = RG-1.183, Tables 3 Section 3.2 Release Fractions and Timings GAP EARLY IN-VESSEL 0.0036 hrs 0.0000 hrs NOBLES 1.OOOOE-01 0.OOOOE+00 IODINE 1.0000E-01 0.0000E+00 CESIUM 0.OOOOE+00 0.0000E+00 TELLURIUM 0.OOOOE+00 0.OOOOE+00 STRONTIUM 0.OOOOE+00 0.OOOOE+00 BARIUM 0.OOOOE+00 0.0000E+00 RUTHENIUM 0.0000E+00 0.OOOOE+00 CERIUM 0.OOOOE+00 O.OOOOE+00 LANTHANUM 0.OOOOE+00 0.OOOOE+00 Iodine fractions Aerosol 0.OOOOE+00 Elemental 5.7000E-01 Organic 4.3000E-01 COMPARTMENT DATA Compartment number 1: Containment Compartment number 2: Environment Compartment number 3: Control Room Compartment Filter Data Time (hr) Flow Rate Filter Efficiencies (%)
(cfm) Aerosol Elemental Organic 7.2000E+01 3.0800E+04 0.0000E+00 0.OOOOE+00 0.OOOOE+00 7.2500E+01 3.0800E+04 9.9000E+01 7.5000E+01 7.5000E+01 7.9200E+02 3.0800E+04 0.OOOOE+00 0.OOOOE+00 0.0000E+00 PATHWAY DATA Pathway number 1: Containment to Environment Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies C%)
(cfm) Aerosol Elemental Organic 7.2000E+01 1.6580E+05 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 7.4000E+01 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 7.9200E+02 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Pathway number 2: Control Room Air Intake Pathway Filter: Removal Data Time (hr) Flow Rate Filter* Efficiencies (%)
(cfm) Aerosol Elemental Organic 7.2000E+01 4.OOOOE+03 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 7.2500E+01 7.2000E+03 9.9000E+01 7.5000E+01 7.5000E+01 7.9200E+02 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Pathway number 3: Control Room Unfiltered Inleakage Pathway Filter: Removal Data
I CALCULATION NOC-I 101 -900-EOOO-083 I REV. No. 2 l PAGE NO. 190 .
Time (hr) Flow Rate Filter Efficiencies (%)
(cfm) Aerosol Elemental Organic 7.2000E+01 1.OOOOE+03 0.OOOOE+00 0.0000E+00 0.OOOOE+00 7.9200E+02 0.000OE+00 0.OOOOE+00 0.OOOOE+00 O.OOOOE+00 Pathway number 4: Control Room Exhaust to Environment Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)
(cfm) Aerosol Elemental Organic 7.2000E+01 5.OOOOE+03 O.OOOOE+00 O.OOOOE+00 0.OOOOE+00 7.2500E+01 8.2000E+03 1.OOOOE+02 1.OOOOE+02 1.OOOOE+02 7.9200E+02 O.OOOOE+00 O.OOOOE+00 0.OOOOE+00 0.OOOOE+00 LOCATION DATA Location Exclusion Area Boundary is in compartment 2 Location X/Q Data Time (hr) X/Q (s
- mA-3) 7.2000E+01 8.OOOOE-04 7.2000E+02 O.OOOOE+00 Location Breathing Rate Data Time (hr) Breathing Rate (m^3
- sec^-l) 7.2000E+01 3.5000E-04 7.2000E+02 0.OOOOE+00 Location Low Popula
- ation Zone is in compartment 2 Location X/Q Data Time (hr) X/SQ (s
- m^-3) 7.2000E+01 1.4000E-04 7.4000E+01 6.OOOOE-05 8.OOOOE+01 3.9000E-05 9.6000E+01 1.6000E-05 1.6800E+02 4.OOOOE-06 7.9200E+02 0.OOOOE+00 Location Breathing Rai:e Daata Time (hr) Breeathi.ng Rate (mA3
- se C-1 )
7.2000E+01 3.5000E-04 8.OOOOE+01 1.8000E-04 9.6000E+01 2.3000E-04 7.9200E+02 O.OOOOE+00 Location Control Room is in compartment 3 Location X/Q Data Time (hr) XA Q (s
- m^-3) 7.2000E+01 5.3400E-04 7.4000E+01 3.1000E-04 8.OOOOE+01 1.3600E-04 9.6000E+01 9.7000E-05 1.6800E+02 6.0200E-05 7.9200E+02 0.OOOOE+00 Location Breathing Rat:e Data Time (hr) Br(eathing Rate (m^3
- sec^-1) 7.2000E+01 3.5000E-04 7.9200E+02 0.0000E+00 Location Occupancy Facctor Data Time (hr) Occcupancy Factor 7.2000E+01 1.OOOOE+00 9.6000E+01 6.OOOOE-01 1.6800E+02 4.0000E-01 7.9200E+02 0.OOOOE+00
11
- - -Cl
.I PA] -------- - ---- --- ---- ---
I No. 2 ATION NOC- I I 0 1-WX)-E0(X)-0X3 NU.I191 I PAl Pill ATION NOP- 1101 LMXJ.E0(X)0X3 I KEV No.
I R-EV- 2 I I PAGh FAUINU. 191 USER SPECIFIED TIME STEP DATA - SUPPLEMENTAL TIME STEPS Time Time step 0.OOOOE+00 1.0000E-01 2.OOOOE+00 5.000oE-01 8.OOOOE+00 1.0000E+00 2.4000E+01 2.OOOOE+00 9.6000E+01 4.OOOOE+00 7.2000E+02 0.OOOOE+00 RADTRAD Version 3.02 run on 7/07/2005 at 7:53:39 ifififif if if #####ifi #####if #f if #if #f # # if #f if ifif #f # #f # #f #f if if# # #f #####if #f if if# #f #f # if
- #if #f # #f #f
- i ###i # #f #
Dose, Detailed model and Detailed Inventory Output Exclusion Area Boundary Doses:
Time (h) = 72.0036 Whole Body Thyroid TEDE Delta dose (rem) 3.9946E-03 1.0846E+00 3.7073E-02 Accumulated dose (rem) 3.9946E-03 1.0846E+00 3.7073E-02 Low Population Zone Doses:
Time (h) = 72.0036 Whole Body Thyroid TEDE Delta dose (rem) 6.9906E-04 1.8981E-01 6.4878E-03 Accumulated dose (rem) 6.9906E-04 1.8981E-01 6.4878E-03 Control Room Doses:
Time (h) = 72.0036 Whole Body Thyroid TEDE Delta dose (rem) 2.5519E-07 1.2176E-03 3.7387E-05 Accumulated dose (rem) 2.5519E-07 1.2176E-03 3.7387E-05 Control Room Compartment Nuclide Inventory:
Time (h) = 72.0036 Ci kg Atoms Bq Kr-85 2.0817E-02 5.3058E-08 3.7591E+17 7.7022E+08 Kr-85m 3.3667E-06 4.0910E-16 2.8984E+09 1.2457E+05 Kr-88 1.5065E-08 1.2014E-18 8.2219E+06 5.5741E+02 I-131 4.3989E-03 3.5482E-11 1.6311E+14 1.6276E+08 I-133 6.7593E-04 5.9669E-13 2.7017E+12 2.5009E+07 1-135 3.6515E-06 1.0398E-15 4.6383E+09 1.3511E+05 Xe-133 1.0054E+00 5.3711E-09 2.4320E+16 3 .7199E+10 Xe-135 2.2653E-03 8.8705E-13 3.9570E+12 8.3816E+07 Control Room Transport Group Inventory:
Overlying Time (h) = 72.0036 Atmosphere Sump Pool Noble gases (atoms) 4.0024E+17 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 9.4518E+13 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) 7.1303E+13 0.OOOOE+00 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00
I CALCULATION NOC-I 101 -900-EOOO.083 I REV. No. 2 1 PAGE NO. 192 l Deposition Recirculating Time (h) = 72.0036 Surfaces Filter Noble gases (atoms) O.OOOOE+00 0.0000E+00 Elemental I (atoms) 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) o.OOOOE+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 72.0036 Filter Noble gases (atoms) O.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 72.0036 Filter Noble gases (atoms) 0.0000E+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 72.0036 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 72.5000 Whole Body Thyroid TEDE Delta dose (rem) 4.3151E-01 1.1720E+02 4.0058E+00 Accumulated dose (rem) 4.3551E-01 1.1829E+02 4.0429E+00 Low Population Zone Doses:
Time (h) = 72.5000 Whole Body Thyroid TEDE Delta dose (rem) 7.5515E-02 2. 0510E+01 7.0101E-01 Accumulated dose (rem) 7.6214E-02 2.0700E+01 7.0750E-01 Control Room Doses:
Time (h) = 72.5000 Whole Body Thyroid TEDE Delta dose (rem) 5.2760E-03 2.5188E+01 7.7343E-01 Accumulated dose (rem) 5.2763E-03 2.5190E+01 7.7347E-01 Control Room Compartment Nuclide Inventory:
Time (h) 72. 5000 Ci kg Atoms Bq Kr-85 1.5368E+00 3.9169E-06 2.7751E+19 5.6860E+10 Kr-85m 2.3017E-04 2.7968E-14 1.9815E+11 8.5162E+06 Kr-88 9.8526E-07 7.8574E-17 5.3771E+08 3.6455E+04 1-131 3.2416E-01 2. 6147E-09 1.2020E+16 1. 1994E+10 I-133 4.9081E-02 4.3327E-l1 1.9618E+14 1.8160E+09 1-135 2.5589E-04 7.2866E-14 3.2504E+ll 9.4681E+06 Xe-133 7.4017E+01 3.9543E-07 1.7905E+18 2.7386E+12 Xe-135 1.6102E-01 6.3053E-ll 2.8127E+14 5.9577E+09 Control Room Transport Group Inventory:
Overlying
I CALCULATION NOC-1 101-900-EOOO-083 I REV. No. 2 l PAGE NO. 193 Time (h) = 72.5000 Atmosphere Sump Pool Noble gases (atoms) 2.9547E+19 0.0000E+00 0.OOOOE+00 Elemental I (atoms) 6.9776E+15 0.OOOOE+00 0.0000E+00 Organic I (atoms) 5.2638E+15 O.OOOOE+00 0.0000E+00 Aerosols (kg) 0.OOOOE+00 0.0000E+00 0.OOOOE+00 Deposition Recirculating Time (h) = 72.5000 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.0000E+00 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 O.OOOOE+00 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 72.5000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 72.5000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.0000E+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 72.5000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 74.0000 Whole Body Thyroid TEDE Delta dose (rem) 4.8991E-02 1.3212E+01 4.5189E-01 Accumulated dose (rem) 4.8450E-01 1.3150E+02 4.4948E+00 Low Population Zone Doses:
Time (h) = 74.0000 Whole Body Thyroid TEDE Delta dose (rem) 8.5734E-03 2.3121E+00 7.9082E-02 Accumulated dose (rem) 8.4787E-02 2.3012E+01 7.8658E-01 Control Room Doses:
Time (h) = 74.0000 Whole Body Thyroid TEDE Delta dose (rem) 7.7628E-03 9.6650E+00 3.0251E-01 Accumulated dose (rem) 1.3039E-02 3.4854E+01 1.0760E+00 Control Room Compartment Nuclide Inventory:
Time (h) = 74.0000 Ci kg Atoms Bq Kr-85 1.1834E-01 3.0163E-07 2.1370E+18 4.3786E+09 Kr-85m 1.4054E-05 1.7077E-15 1.2099E+10 5.1998E+05 Kr-88 5.2612E-08 4.1958E-18 2.8713E+07 1.9467E+03 I-131 5.0945E-05 4.1093E-13 1.8891E+12 1.8850E+06 I-133 7.3771E-06 6.5122E-15 2.9487E+10 2.7295E+05 I-135 3.4548E-08 9.8377E-18 4.3884E+07 1.2783E+03 Xe-133 5.6530E+00 3.0200E-08 1.3675E+17 2.0916E+11
ICALCULATION NOC-I 101-900-E000-083 l REV. No. 2 I PAGE NO. 194 l Xe-135 1.1060E-02 4.3307E-12 1.9319E+13 4.0920E+08 Control Room Transport Group Inventory:
Overlying Time (h) = 74.0000 Atmosphere Sump Pool Noble gases (atoms) 2.2753E+18 O.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 1.1025E+12 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) 8.3173E+11 0.OOOOE+00 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Deposition Recirculating Time (h) = 74.0000 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 5.5974E+15 Organic I (atoms) 0.0000E+00 4.2226E+15 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 74.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 4.5573E+20 Organic I (atoms) 3.4379E+20 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 74.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 74.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 1.9870E+15 Organic I (atoms) 1.4989E+15 Aerosols (kg) 0.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 80.0000 Whole Body Thyroid TEDE Delta dose (rem) 2.6487E-05 0.OOOOE+00 2.6487E-05 Accumulated dose (rem) 4.8453E-01 1.3150E+02 4.4948E+00 Low Population Zone Doses:
Time (h) = 80.0000 Whole Body Thyroid TEDE Delta dose (rem) 1.9865E-06 0.OOOOE+00 1.9865E-06 Accumulated dose (rem) 8.4789E-02 2.3012E+01 7.8658E-01 Control Room Doses:
Time (h) = 80.0000 Whole Body Thyroid TEDE Delta dose (rem) 4.8847E-04 1.3973E-03 5.3107E-04 Accumulated dose (rem) 1.3528E-02 3.4856E+01 1.0765E+00 Control Room Compartment Nuclide Inventory:
Time (h) = 80.0000 Ci kg Atoms Bq Kr-85 8.9354E-07 2.2775E-12 1.613 6E+13 3 .3061E+04 Xe-133 4.1298E-05 2.2063E-13 9.9900E+11 1.5280E+06
IFCALCULATION ACLTO NO-1O190EO08IRE.N.2IPGNO15 NOC-1 101-900-EOOO-083 I REV-No. 2 I PAGE NO. 195 I Xe-135 5.2849E-08 2.0695E-17 9.2317E+07 1.9554E+03 Control Room Transport Group Inventory:
Overlying Time (h) = 80.0000 Atmosphere Sump Pool Noble gases (atoms) 1.7181E+13 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 2.9367E-08 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) 2.2154E-08 0.OOOOE+00 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Deposition Recirculating Time (h) = 80.0000 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 5.5982E+15 Organic I (atoms) 0.0000E+00 4.2232E+15 Aerosols (kg) 0.OOOOE+00 0.0000E+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 80.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 4.5573E+20 Organic I (atoms) 3.4379E+20 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 80.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 80.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 1.9872E+15 Organic I (atoms) 1.4992E+15 Aerosols (kg) 0.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 96.0000 Whole Body Thyroid TEDE Delta dose (rem) 1.9243E-10 0.OOOOE+00 1.9243E-10 Accumulated dose (rem) 4.8453E-01 1.3150E+02 4.4948E+00 Low Population Zone Doses:
Time (h) = 96.0000 Whole Body Thyroid TEDE Delta dose (rem) 9.3811E-12 0.OOOOE+00 9.3811E-12 Accumulated dose (rem) 8.4789E-02 2.3012E+01 7.8658E-01 Control Room Doses:
Time (h) = 96.0000 Whole Body Thyroid TEDE Delta dose (rem) 3.5487E-09 3.6284E-23 3.5487E-09 Accumulated dose (rem) 1.3528E-02 3.4856E+01 1.0765E+00 Control Room Compartment Nuclide Inventory:
Time (h) = 96.0000 Ci kg Atoms Bq Control Room Transport Group Inventory:
I CALCULATION NOC-1I 10 -900-EOOO-083 I REV. No. 2 PAGE NO. 196 Overlying Time (h) = 96.0000 Atmosphere
- Sump Pool Noble gases (atoms) 3.6913E-01 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 1.8527E-60 O.OOOOE+00 0.OOOOE+00 Organic I (atoms) 1.3977E-60 0.0000E+00 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 0.0000E+00 0.OOOOE+00 Deposition Recirculating Time (h) = 96.0000 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 5.5982E+15 Organic I (atoms) 0.OOOOE+00 4.2232E+15 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 4.5573E+20 Organic I (atoms) 3.4379E+20 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 96.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 1.9872E+15 Organic I (atoms) 1.4992E+15 Aerosols (kg) 0.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 168.0000 Whole Body Thyroid TEDE Delta dose (rem) 3.7707E-24 0.OOOOE+00 3.7707E-24 Accumulated dose (rem) 4.8453E-01 1.3150E+02 4.4948E+00 Low Population Zone Doses:
Time (h) = 168.0000 Whole Body Thyroid TEDE Delta dose (rem) 7.5414E-26 0.OOOOE+00 7.5414E-26 Accumulated dose (rem) 8.4789E-02 2.3012E+01 7.8658E-01 Control Room Doses:
Time (h) = 168.0000 Whole Body Thyroid TEDE Delta dose (rem) 8.5077E-23 9.2413E-75 8.5077E-23 Accumulated dose (rem) 1.3528E-02 3.4856E+01 1.0765E+00 Control Room Compartment Nuclide Inventory:
Time (h) = 168.0000 Ci kg Atoms Eq Control Room Transport Group Inventory:
Overlying Time (h) = 168.0000 Atmosphere Sump Pool
I CALCULATION NOC-1 101-900-E000-083 I REV. No. 2 l PAGE NO. 197 l Noble gases (atoms) 1.1284E-62 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 2.3168-295 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) 1.7477-295 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.OOOOE+00 0.0000E+00 Deposition Recirculating Time (h) = 168.0000 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 O.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 5.5982E+15 Organic I (atoms) 0.OOOOE+00 4.2232E+15 Aerosols (kg) 0.0000E+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 168.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 4.5573E+20 Organic I (atoms) 3.4379E+20 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 168.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 168.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 1.9872E+15 Organic I (atoms) 1.4992E+15 Aerosols (kg) 0.0000E+00 Exclusion Area Boundary Doses:
Time (h) = 720.0000 Whole Body Thyroid TEDE Delta dose (rem) 7.7374E-86 0.OOOOE+00 7.7374E-86 Accumulated dose (rem) 4.8453E-01 1.3150E+02 4.4948E+00 Low Population Zone Doses:
Time (h) = 720.0000 Whole Body Thyroid TEDE Delta dose (rem) 3.8687E-88 0.OOOOE+00 3.8687E-88 Accumulated dose (rem) 8.4789E-02 2.3012E+01 7.8658E-01 Control Room Doses:
Time (h) = 720.0000 Whole Body Thyroid TEDE Delta dose (rem) 2.2404E-84 1.1767-309 2.2404E-84 Accumulated dose (rem) 1.3528E-02 3.4856E+01 1.0765E+00 Control Room Compartment Nuclide Inventory:
Time (h) = 720.0000 Ci kg Atoms Bq Control Room Transport Group Inventory:
Overlying Time (h) = 720.0000 Atmosphere Sump Pool Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00
CALCULATION NOC-I10 I-900-EOOO-083 I REV. No. 2 l PAGE NO. 198 l Aerosols (kg) 0.OOOOE+00 0.0000E+00 0.OOOOE+00 Deposition Recirculating Time (h) = 720.0000 Surfaces Filter Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 5.5982E+15 Organic I (atoms) 0.OOOOE+00 4.2232E+15 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 4.5573E+20 Organic I (atoms) 3.4379E+20 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.0000E+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 720.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 1.9872E+15 Organic I (atoms) 1.4992E+15 Aerosols (kg) 0.OOOOE+00 Exclusion Area Boundary Doses:
Time (h) = 792.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Accumulated dose (rem) 4.8453E-01 1.3150E+02 4.4948E+00 Low Population Zone Doses:
Time (h) = 792.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Accumulated dose (rem) 8.4789E-02 2.3012E+01 7.8658E-01 Control Room Doses:
Time (h) = 792.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Accumulated dose (rem) 1.3528E-02 3.4856E+01 1.0765E+00 Control Room Compartment Nuclide Inventory:
Time (h) = 792.0000 Ci kg Atoms Bq Control Room Transport Group Inventory:
Overlying Time (h) = 792.0000 Atmosphere Sump Pool Noble gases (atoms) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 0.OOOOE+00 0.OOOOE+00 Deposition Recirculating
I CALCULATION NOC-1101-900-EOOO-083 l REV. No. 2 l PAGE NO. 199 Time (h) = 792.0000 Surfaces Filter Noble gases (atoms) 0.0000E+00 O.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 5.5982E+15 Organic I (atoms) 0.OOOOE+00 4.2232E+15 Aerosols (kg) 0.0000E+00 O.OOOOE+00 Control Room Air Intake Transport Group Inventory:
Pathway Time (h) = 792.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 4.5573E+20 Organic I (atoms) 3.4379E+20 Aerosols (kg) 0.OOOOE+00 Control Room Unfiltered Inleakage Transport Group Inventory:
Pathway Time (h) = 792.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 0.OOOOE+00 Organic I (atoms) 0.OOOOE+00 Aerosols (kg) 0.OOOOE+00 Control Room Exhaust to Environment Transport Group Inventory:
Pathway Time (h) = 792.0000 Filter Noble gases (atoms) 0.OOOOE+00 Elemental I (atoms) 1.9872E+15 Organic I (atoms) 1.4992E+15 Aerosols (kg) 0.OOOOE+00 334 1-131 Summary Containment Environment Control Room Time (hr) 1-131 (Curies) I-131 (Curies) I-131 (Curies) 72.001 6.5355E+01 8.3646E-02 1.0538E-04
- 72. 004 4.2054E+02 3.4959E+00 4.3989E-03 72.400 6.7659E+01 3.5615E+02 3.3229E-01 72.500 4.2673E+01 3.8115E+02 3.2416E-01 72.800 1.0706E+01 4.1309E+02 4.0973E-02 73.100 2.6861E+00 4.2110E+02 6.0459E-03 73.400 6.7390E-01 4.2311E+02 1.0727E-03 73.700 1.6907E-01 4.2362E+02 2.2254E-04
- 74. 000 4.2419E-02 4.2374E+02 5.0945E-05 74.300 4.2373E-02 4.2374E+02 5.3445E-06 74.600 4.2328E-02 4.2374E+02 5.6068E-07 74.900 4.2282E-02 4.2374E+02 5.8819E-08 75.200 4.2236E-02 4.2374E+02 6.1705E-09
- 75. 500 4.2191E-02 4.2374E+02 6.4734E-10
- 75. 800 4.2146E-02 4.2374E+02 6.7910E-11 76.100 4.2100E-02 4.2374E+02 7.1243E-12 76.400 4.2055E-02 4.2374E+02 7.4739E-13 76.700 4.2010E-02 4.2374E+02 7.8407E-14 77.000 4.1964E-02 4.2374E+02 8.2254E-15 77.300 4.1919E-02 4.2374E+02 8.6291E-16 77.600 4.1874E-02 4.2374E+02 9.0525E-17 77.900 4.1829E-02 4.2374E+02 9.4968E-18 78.200 4.1784E-02 4.2374E+02 9.9628E-19 78.500 4.1739E-02 4.2374E+02 1.0452E-19 78.800 4.1694E-02 4.2374E+02 1.0965E-20 79.100 4.1649E-02 4.2374E+02 1.1503E-21 79.400 4.1604E-02 4.2374E+02 1.2067E-22
CALCULATION NOC-I 101-900-EOOO-083 I REV. No. 2 l PAGE NO. 200 79.700 4.1559E-02 4.2374E+02 1.2659E-23
- 80. 000 4.1514E-02 4.2374E+02 1.3281E-24 80.300 4.1470E-02 4.2374E+02 1.3932E-25
- 80. 600 4 .1425E-02 4.2374E+02 1.4616E-26 80.900 4 .1380E-02 4.2374E+02 1.5333E-27 81.200 4 .1336E-02 4.2374E+02 1.6086E-28 81.500 4.1291E-02 4.2374E+02 1.6875E-29
- 81. 800 4.1247E-02 4.2374E+02 1.7703E-30 82.100 4.1202E-02 4.2374E+02 1. 8572E-31 82.400 4.1158E-02 4.2374E+02 1.9483E-32
- 96. 000 3 .9196E-02 4.2374E+02 7.9104E-77 168. 000 3.0263E-02 4.2374E+02 7.6375-312 720.000 4.1664E-03 4.2374E+02 O.OOOOE+00 792. 000 3 .2169E-03 4.2374E+02 O.OOOOE+00 Cumulative Dose Summary Exclusion Area Bounda Low Population Zone Contro]L Room Time Thyroid TEDE Thyroid TEDE Thyroid TEDE (hr) (rem) (rem) (rem) (rem) (rem) (rem) 72.001 2.5952E-02 8.8702E-04 4.5415E-03 1.5523E-04 5.7730E-06 1.7727E-07 72.004 1.0846E+00 3.7073E-02 1.8981E-01 6.4878E-03 1.2176E-03 3.7387E-05 72.400 1.1053E+02 3.7778E+00 1.9343E+01 6.6111E-01 1. 8717E+01 5.7473E-01 72.500 1.1829E+02 4.0429E+00 2.0700E+01 7.0750E-01 2.5190E+01 7.7347E-01 72.800 1.2819E+02 4.3816E+00 2.2434E+01 7.6678E-01 3.3540E+01 1.0314E+00 73.100 1.3068E+02 4.4667E+00 2.2869E+01 7.8166E-01 3.4642E+01 1.0672E+00 73.400 1.3130E+02 4.4880E+00 2.2978E+01 7.8540E-01 3.4815E+01 1.0737E+00 73.700 1.3146E+02 4.4934E+00 2.3005E+01 7.8634E-01 3.4848E+01 1.0754E+00 74.000 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.4854E+01 1.0760E+00 74.300 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.4856E+01 1.0762E+00
- 74. 600 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.4856E+01 1.0764E+00 74.900 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.4856E+01 1.0764E+00 75.200 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.4856E+01 1.0765E+00 75.500 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.4856E+01 1.0765E+00 75.800 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.4856E+01 1.0765E+00 76.100 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.4856E+01 1.0765E+00 76.400 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.4856E+01 1.0765E+00 76.700 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.4856E+01 1.0765E+00 77.000 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.4856E+01 1.0765E+00 77.300 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.4856E+01 1.0765E+00 77.600 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.4856E+01 1.0765E+00 77.900 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.4856E+01 1.0765E+00 78.200 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.4856E+01 1.0765E+00 78.500 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.4856E+01 1.0765E+00
- 78. 800 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.4856E+01 1.0765E+00 79.100 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.4856E+01 1.0765E+00 79.400 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.4856E+01 1.0765E+00 79.700 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.4856E+01 1.0765E+00
- 80. 000 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.4856E+01 1.0765E+00 80.300 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.4856E+01 1.0765E+00
- 80. 600 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.4856E+01 1.0765E+00
- 80. 900 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.4856E+01 1.0765E+00 81.200 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.4856E+01 1.0765E+00 81.500 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.4856E+01 1.0765E+00
- 81. 800 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.4856E+01 1.0765E+00 82.100 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.4856E+01 1.0765E+00 82.400 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.4856E+01 1.0765E+00
- 96. 000 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.4856E+01 1.0765E+00 168. 000 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.4856E+01 1.0765E+00 720. 000 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.4856E+01 1.0765E+00 792.000 1.3150E+02 4.4948E+00 2.3012E+01 7.8658E-01 3.4856E+01 1.0765E+00 Worst Two-Hour Doses Note: All of the dose locations are shown below but the worst two-hour dose is only meaningful for the EAB
CALCULATION NOC- I01-900-EOOO-083 l REV. No. 2 l PAGE NO. 201 dose location. Please disregard the two-hour worst doses for the other dose locations Exclusion Area Boundary Time Whole Body Thyroid TEDE (hr) (rem) (rem) (rem) 72.0 4.8440E-01 1.3147E+02 4.4939E+00 Low Population Zone Time Whole Body Thyroid TEDE (hr) (rem) (rem) (rem) 72.0 8.4771E-02 2.3008E+01 7.8643E-01 Control Room Time Whole Body Thyroid TEDE (hr) (rem) (rem) (rem) 72.0 1.3039E-02 3.4854E+01 1.0760E+00
ENCLOSURE 3 List of Commitments 5928-05-20176 Page 1 of 1
SUMMARY
OF AMERGEN COMMITMENTS The following table identifies commitments made in this document by AmerGen. (Any other actions discussed in the submittal represent intended or planned actions by AmerGen. They are described to the NRC for the NRC's information and are not regulatory commitments.)
COMMITMENT COMMITTED DATE OR "OUTAGE" TMI Unit 1 administrative controls will require that T1R16 qualified personnel be designated, that required tools or (Fall 2005) equipment be identified and staged, and that required guidance be provided to ensure that, in the event of a fuel handling accident inside containment, containment equipment hatch closure is achieved within 45 minutes following an evacuation of the containment. Such prompt closure methods need not completely block the equipment hatch opening or be capable of resisting pressure. The 45-minute closure time is considered to begin when the control room communicates the need to shut the containment structure equipment hatch opening.
An acceptance test will be performed to ensure that the T1R16 temporary equipment hatch cover can be installed within (Fall 2005) 45 minutes to serve the intended function with the full design Reactor Building purge flow in effect.
I-TMI Unit 1 UFSAR Section 14.2.2.1 will be revised to UFSAR Update 18 accurately identify the appropriate analysis assumptions (April 2006) and parameters described in Enclosure 2.
+
TMI Unit 1 UFSAR Section 14.2.2.1 will be revised to UFSAR Update 18 clarify that FHA analysis dose consequences are based (April 2006) on a limiting steady-state radial-local peaking factor of 1.70, as approved in Amendment No. 247, dated October 20, 2003.