Two Inch Break Broken Loop Pump Suction Cross Over Leg Liquid Level Mixture Level Bottom of Cross-over Leg Top of Cross-over Leg 20-18

% 16-

=E 14-12-10*

l l l l l l l l l l l l 0

1000 2000 3000 4000 5000 Time (s)

Three Inch Break Broken Loop Pump Suction Cross Over Mixture Level Bottom of Cross-over Leg Top of Cross-over Leg Leg Liquid Level 1-J I.-

18 16 14 12 0

500 1000 1500 Time (S) 2000 2500 3000

Four Inch Break Broken Loop Pump Suction Cross Over Leg Liquid Level Mixture Level Bottom of Cross-over Leg Top of Cross-over Leg 16-

=

=E 14' 12' 10' l

l l

l l

l l

l l

l l

l 0

500 1000.

1500 2000 Time (s)

Six Inch Break Broken Loop Pump Suction Cross Over Leg Liquid Level Mixture Level Bottom of Cross-over Leg

__ Top of Cross-over Leg 280 A8

-J a).

,xD,

-___a____---i---

I--

=E 14 2-Ian

......... aj..

IU 0 200 400 600 Time (s) 800 1000

Six Inch Break Lumped Intact Loop Pump Suction Cross Over Leg Liquid Level Mixture Level Bottom of Cross-over Leg Top of Cross-over Leg 1

-I.-

2 O

14 12 in I I

I I

I I

I I

I I

I I

I I

I 0

200 400 600 Time (s) 800 1000