Enclosure 1 Watts Bar Nuclear Plant 2004 Annual Radioactive Effluent Release Report El-I

2004 WATTS BAR NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SUPPLEMENTAL INFORMATION

1. Regulatory Limits A.

Gaseous Effluents

1. Dose rates due to radioactivity released in gaseous effluents from the site to areas at and beyond the unrestricted area boundary shall be limited to the following:
a. Noble gases: - Less than or equal to 500 mrernlyear to the total body.

- Less than or equal to 3000 mremlyear to the skin.

b.

Iodine-1 31, iodine-133, tritium, and all radionuclides in particulate form with half-lives greater than 8 days:

- Less than or equal to 1500 mrem/year to any organ.

2.

Air dose due to noble gases released in gaseous effluents to areas at and beyond the unrestricted area boundary shall be limited to the following:

a. Less than or equal to 5 mrad for gamma radiation and less than or equal to 10 mrad for beta radiation during any calendar quarter.
b. Less than or equal to 10 mrad for gamma radiation and less than or equal to 20 mrad for beta radiation during any calendar year.
3.

Dose to a member of the public from iodine-131, iodine-1 33, tritium, and all radionuclides in particulate form with half-lives greater than eight days in gaseous effluents released to areas at and beyond the unrestricted area boundary shall be limited to the following:

a. Less than or equal to 7.5 mrem to any organ during any calendar quarter.
b. Less than or equal to 15 mrem to any organ during any calendar year.

B. Liquid Effluents

1. The concentration of radioactivity released in liquid effluents to unrestricted areas shall be limited to 10 times the concentrations specified in Title 10 of the Code of Federal Regulations, Part 20 (Standards for Protection Against Radiation), Appendix B, Table 2, Column 2, for radionuclides other than dissolved or entrained noble gases. For dissolved or entrained noble gases, the concentration shall be limited to 2.0 E-04 gCi/ml total activity.
2. The dose or dose commitment to a member of the public from radioactivity in liquid effluents released to unrestricted areas shall be limited to:
a. Less than or equal to 1.5 mrem to the total body and less than or equal to 5 mrem to any organ during any calendar quarter.
b. Less than or equal to 3 mrem to the total body and less than or equal to 10 mrem to any organ during any calendar year.

E1-2

2004 WATTS BAR NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SUPPLEMENTAL INFORMATION

2. Effluent Concentration Limits A.

Liquids The Effluent Concentration Limits (ECL) for liquids are those listed in 10 CFR 20, Appendix B, Table 2, Column 2. For dissolved and entrained gases the ECL of 2.OE-04 jgCi/ml is applied. This ECL is based on the Xe-135 concentration in air (submersion dose) converted to an equivalent concentration in water as discussed in the International Commission on Radiological Protection (ICRP), Publication 2.

B. Gaseous Concentration limits for gaseous releases are met through compliance with the maximum permissible dose rates for gaseous releases as defined in plant Offsite Dose Calculation Manual (ODCM) and presented in Section 1.A.1 of this report.

3.

Average Energy Watts Bar's ODCM limits the dose equivalent rates due to the release of noble gases to less than or equal to 500 mrem/year to the total body and less than or equal to 3000 mrem/year to the skin.

Therefore, the average beta and gamma energies (E) for gaseous effluents as described in Regulatory Guide 1.21, "Measuring, Evaluation, and Reporting Radioactivity in Solid Wastes and Releases of Radioactive Materials in Liquid and Gaseous Effluents from Light-Water-Cooled Nuclear Power Plants," are not applicable.

4.

Measurements And Approximations Of Total Radioactivity Radioactivity measurements performed in support of the WBN Offsite Dose Calculation Manual (ODCM) meet the Lower Limit of Detection requirements given in ODCM Tables 2.2-1 and 2.2-2.

A.

Liquid Effluents Batch (Radwaste and Condensate Demineralizer tanks)

Total gamma isotopic activity concentrations are determined on each Radwaste batch tank prior to release. The total activity of a batch release is obtained by determining the concentration of each nuclide and then multiplying by the volume discharged to arrive at the curie concentration for each nuclide. The curies of each nuclide are then summed. Composite samples are maintained and analyzed monthly for tritium and gross alpha, and quarterly for Iron-55, Strontium-89, and Strontium-90. During periods of no significant identified primary to secondary leakage, the volume from each Condensate Demineralizer tank release is obtained and the feedwater tritium concentration is used to determine the curies of tritium released.

Continuous Releases (Turbine Building Sump and Steam Generator Blowdown)

During periods of no significant identified primary to secondary leakage, the volume released from the TBS and SGB is obtained. The TBS tritium concentration is determined via weekly grab samples. The feedwater tritium concentration is used to determine the curies of tritium released from SGB.

E1-3 n-

't-

2004 WATTS BAR NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SUPPLEMENTAL INFORMATION B. Fission and Activation Gases Airborne effluent gaseous activity is continuously monitored and recorded. Weekly grab samples from the auxiliary building and monthly grab samples from the service building are taken and analyzed to determine the quantity of noble gas activity released based on the total flows for the sample period. Also, noble gas samples are collected and evaluated following startup, shutdown, or rated thermal power change exceeding 15 percent within one hour (sampling only required if dose equivalent 1-131 concentration in the primary coolant or the noble gas activity monitor shows that the containment activity has increased more than a factor of 3).

The quantity of noble gases released through the shield building exhaust due to purging of containment is determined by sampling prior to the beginning of the purge. The total activity released is determined from the total flow recorded for each purge. Also, noble gas samples are collected and evaluated for ongoing containment purges following startup, shutdown, or rated thermal power change exceeding 15 percent within one hour (sampling only required if dose equivalent 1-131 concentration in the primary coolant or the noble gas activity monitor shows that the containment activity has increased more than a factor of 3).

The quantity of noble gases released through the shield building exhaust due to the batch release of waste gas decay tanks is determined by sampling each tank prior to release. The total activity released is determined from the total pressure change recorded for the tank during the release.

C. lodines and Particulates in Gaseous Releases Iodine and particulate activity is continuously sampled. Charcoal and particulate samples are taken from the shield and auxiliary building exhausts and analyzed at least weekly to determine the total activity released from the plant based on the total vent flows recorded for the sampling period. Also, particulate and charcoal samples are taken from the auxiliary and shield building exhausts once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> for 7 days following startup, shutdown, or a rated thermal power change exceeding 15 percent within one hour (if dose equivalent 1-131 concentration in the primary coolant or the noble gas activity monitor shows that the containment activity has increased more than a factor of 3).

EI-4

2004 WATTS BAR NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SUPPLEMENTAL INFORMATION

5. Batch Releases Value 1 st Half 2nd Half Units A. Liquid (Radwaste only)
1. Number of releases 25 41 Each
2. Total time period of releases 5139 9258 Minutes
3. Maximum time period of release 425 855 Minutes
4. Average time period of releases 206 226 Minutes
5. Minimum time period for release 1

1 Minutes

6. Average dilution stream flow during 23,724 41,688 CFS release periods B. Gaseous (Batches only - containment purges, and waste gas decay tanks)
1. Number of releases 43 55 Each
2. Total time period of releases 37431 61027 Minutes
3. Maximum time period for release 3532 4657 Minutes
4. Average time period for releases 870 1110 Minutes
5. Minimum time period for release 7

2 Minutes

6. Abnormal Releases Value Units 1st Half 2nd Half A. Liquid Number of Releases 0

0 Total Activity Released N/A N/A Ci B. Gaseous Number of Releases 1*

none Total Activity Released 2.98 N/A Ci

  • The Unit 1 Shield Building Exhaust isokinetic flow equipment was removed from service to perform an 18 month channel calibration of the radiation monitor. During the performance of the 18 month channel calibration a valve upstream of where the particulate and iodine compensatory sampler is connected was isolated. In order to support a containment purge the isokinetic equipment was placed back inservice but the opening of the valve upstream of the compensatory sampling equipment was overlooked and left closed. This resulted in an unmonitored release. The activity of the samples taken from containment prior to the release was used estimate the curies released.

El-5

2004 WATTS BAR NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT TABLE 1-A Liquid Effluents - Summation of All Releases Unit: I Starting: I-Jan-2004 Ending: 30-Jun-2004 Est.

Tot Type Of Effluent Units Quarter 1 Quarter 2 Error %

A. Fission & Activation Products

1. Total Release (Not Including Tritium, Ci 8.28E-03 9.53E-03 25%

Gases, Alpha)

2. Average Diluted Concentration During pCi/ml 7.96E-10 9.44E-10 Period
3. Percent Of Applicable Limit B. Tritium
1. Total Release Ci 1.88E+01 1.21E+O1 18%
2. Average Diluted Concentration During ltCi/ml 1.81 E-06 1.20E-06 Period
3. Percent Of Applicable Limit C. Dissolved And Entrained Gases
1. Total Release Ci 3.65E-03 1.03E-03 39%
2. Average Diluted Concentration During

[0Ci/ml 3.50E-10 1.02E-10 Period

3. Percent Of Applicable Limit 1.75E-04 5.OOE-05 D. Gross Alpha Radioactivity
1. Total Release Curies O.OOOE+00**

O.OOOE+00 NOA***

E. Waste Volume Released Liters 2.12E+08 3.36E+08 2%

(Pre-Dilution)

F. Volume Of Dilution Water Used Liters 1.02E+10 9.77E+09 12%

Applicable limits are expressed in terms of dose. See Table 7A of this report.

    • Zeroes in this table indicate that no radioactivity was present at detectable levels.
      • N/A - Errors in measurements are not reported for these values since none were identified during the reporting period.

E1-6

2004 WATTS BAR NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT TABLE 1-B Liquid Effluents - Summation of All Releases Unit: 1 Starting: 1-Jul-2004 Ending: 31-Dec-2004 Est. Tot Type Of Effluent Units Quarter 3 Quarter 4 Error %

A. Fission & Activation Products

1. Total Release (Not Including Ci 1.34E-02 9.61 E-03 25%

Tritium, Gases, Alpha)

2. Average Diluted Concentration RCi/ml 9.93E-10 5.06E-10 During Period
3. Percent Of Applicable Limit B. Tritium
1. Total Release Ci 2.42E+02 4.58E+02 18%
2. Average Diluted Concentration

[LCi/ml 1.79E-05 2.41 E-05 During Period

3. Percent Of Applicable Limit C. Dissolved And Entrained Gases
1. Total Release Ci 9.37E-02 3.1OE-02 39%
2. Average Diluted Concentration tiCi/ml 6.95E-09 1.64E-09 During Period
3. Percent Of Applicable Limit 3.48E-03 8.20E-04 D. Gross Alpha Radioactivity
1. Total Release Ci O.OOE+00**

O.OOE+00 NIA***

E. Waste Volume Released Liters 3.39E+08 5.10E+08 2%

(Pre-Dilution)

F. Volume Of Dilution Water Used Liters 1.32E+10 1.85E+10 12%

Applicable limits are expressed in terms of dose. See Table 78 of this report.

    • Zeroes in this table indicate that no radioactivity was present at detectable levels.
      • N/A - Errors in measurements are not reported for these values since none were identified during the reporting period.

El -7

2004 WATTS BAR NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT TABLE 2-A Liquid Effluents Unit: 1 Starting: 1-Jan-2004 Ending: 30-Jun-2004 Continuous Mode Quarter 1 Quarter 2 Batch Mode Quarter I Quarter 2 Nuclide Unit H-3 Ci 6.91E-01 8.07E-01 1.81E+01 1.13E+01 Fission & Activation Products Ag-11 Om Ci O.OOE+O0 O.OOE+OO 1.11 E-05 O.OOE+00 Co-57 Ci O.OOE+O0 O.OOE+OO 2.38E-05 3.45E-05 Co-58 Ci O.OOE+00 O.OOE+00 4.13E-03 2.39E-03 Co-60 Ci O.OOE+00 O.OOE+00 1.61 E-04 7.26E-04 Fe-55 Ci O.OOE+00 O.OOE+OO 1.65E-03 5.78E-03 1-131 Ci O.OOE+O0 O.OOE+00 6.60E-06 O.OOE+O0 Mn-54 Ci O.OOE+OO O.OOE+OO 2.1 OE-06 6.32E-05 Nb-95 Ci O.OOE+OO O.OOE+00 O.OOE+O0 1.81 E-05 Sb-124 Ci O.OOE+00 O.OOE+00 2.01 E-04 O.OOE+00 Sb-125 Ci O.OOE+00 O.OOE+OO 2.09E-03 5.21E-04 Totals Ci O.OOE+O0 O.OOE+00 8.28E-03 9.53E-03 Dissolved And Entrained Gases Xe-133 Xe-135 Ci Ci O0.OE+QO 0.OOE+00 0.OOE+00 O.OOE+OO O.O0E+OO O.OOE+00 3.59E-03 6.1 BE-05 3.65E-03 1.01 E-03 1.83E-05 1.03E-03 Totals Ci

  • Zeroes in this table indicate that no radioactivity was present at detectable levels.

E1-8

2004 WATTS BAR NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT TABLE 2-B Liquid Effluents Unit: I Starting: I-Jul-2004 Ending: 31-Dec-2004 Continuous Mode Batch Mode Nuclide Unit Quarter 3 Quarter 4 Quarter 3 Quarter 4 H-3 Ci 1.05E+00 2.48E-01 2.41 E+02 4.56E+02 Fission & Activation Products Ag-11 Om Ci O.OOE+00 O.OOE+00 5.77E-06 4.65E-06 Co-57 Ci O.OOE+00 O.OOE+00 2.95E-05 O.OOE+00 Co-58 Ci O.OOE+00 O.OOE+00 8.60E-04 2.39E-04 Co-60 Ci O.OOE+00 O.OOE+00 2.52E-03 2.46E-04 Cr-51 Ci O.OOE+OO O.00E+OO O.OOE+OO 5.60E-05 Cs-1 34 Ci O.OOE+OO O.OOE+OO O.OOE+OO 7.95E-05 Cs-1 37 Ci O.OOE+0O O.OOE+0O O.OOE+0O 5.44E-05 Fe-55 Ci O.OOE+OO O.OOE+OO 7.72E-03 1.71 E-03 1-131 Ci O.00E+OO 4.51E-04 O.OOE+OO 7.88E-06 1-133 Ci O.OOE+OO 1.09E-03 O.OOE+OO O.OOE+OO 1-135 Ci O.OOE+OO 5.02E-04 O.OOE+OO O.OOE+OO Mn-54 Ci O.OOE+OO O.OOE+O0 2.80E-04 4.78E-06 Nb-95 Ci O.OOE+0O O.OOE+OO 7.70E-06 O.OOE+00 Sb-125 Ci O.OOE+0O O.OOE+OO 2.OOE-03 5.16E-03 Totals Ci O.OOE+OO 2.04E-03 1.34E-02 9.60E-03 Dissolved And Entrained Gases Kr-85 Xe-131m Xe-1 33 Xe-1 33m Xe-135 Xe-137 Ci Ci Ci Ci Ci Ci 0.00 E+OO

.0.OE+0O 0.OOE+OO 0.OOE+OO

.0.OE+0O 0.OOE+OO 0.OOE+OO O.OOE+OO O.OOE+00 O.OOE+0O O.OOE+00 O.OOE+OO 6.1 8E-04 6.1 8E-04 1.05E-02 1.37E-03 8.12E-02 5.59E-04 4.82E-05 O.OOE+OO 9.37E-02 2.03E-02 6.45E-04 9.26E-03 O.OOE+0O 1.54E-04 O.OOE+OO 3.04E-02 Totals Ci

  • Zeroes in this table indicate that no radioactivity was present at detectable levels.

El-9

2004 WATTS BAR NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT TABLE 3-A Gaseous Effluents - Summation of All Releases Unit: 1 Starting: I-Jan-2004 Ending: 30-Jun-2004 Est. Tot Type Of Effluent Units Quarter I Quarter 2 Error %

A. Fission & Activation Products

1. Total Release Ci 1.48E+02 1.83E+02 22
2. Average Release Rate For Period IiCi/sec 1.88E+01 2.33E+01
3. Percent Of Applicable Limit B. Radioiodines
1. Total lodine-131 Ci 8.53E-06 7.78E-10 NIA***
2. Average Release Rate For Period pCi/sec 1.09E-06 9.89E-11
3. Percent Of Applicable Limit C. Particulates
1. Particulates (Half-Lives>8 Days)

Ci O.OOOE+00 1.40E-10 N/A***

2. Average Release Rate For Period giCi/sec O.OOOE+00 1.78E-11
3. Percent Of Applicable Limit
4. Gross Alpha Radioactivity Ci O.OOOE+00 O.OOOE+00 D. Tritium
1. Total Release
2. Average Release Rate For Period
3. Percent Of Applicable Limit Ci gCi/sec 3.80E+00 4.84E-01 2.36E+00 3.OOE-01 11 Applicable limits are expressed in terms of dose. See Table 6A of this report.
    • Zeroes in this table indicate that no radioactivity was present at detectable levels.
      • N/A - Errors in measurements are not reported for these values since none were identified during the reporting period.

E1-10

2004 WATTS BAR NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT TABLE 3-B Gaseous Effluents - Summation of All Releases Unit: 1 Starting: 1-Jul-2004 Ending: 31-Dec-2004 Est. Tot Type Of Effluent Units Quarter 3 Quarter 4 Error %

A. Fission & Activation Products

1. Total Release Ci 2.84E+02 3.62E+02 22
2. Average Release Rate For Period pICi/sec 3.58E+01 4.55E+01
3. Percent Of Applicable Limit B. Radioiodines
1. Total lodine-131 Ci 4.18E-06 2.19E-07
      • N/A
2. Average Release Rate For Period

~

iCi/sec 5.26E-07 2.76E-08

3. Percent Of Applicable Limit C. Particulates
1. Particulates (Half-Lives>8 Days)

Ci 1.72E-05 3.16E-06

      • N/A
2. Average Release Rate For Period pCi/sec 2.16E-06 3.98E-07
3. Percent Of Applicable Limit
4. Gross Alpha Radioactivity Ci O.OOOE+00 O.OOOE+00 D. Tritium
1. Total Release
2. Average Release Rate For Period
3. Percent Of Applicable Limit Ci jiCi/sec 4.08E+00 5.13E-01 3.66E+00 4.60E-01 11 Applicable limits are expressed in terms of dose. See Table 6-B of this report.
    • Zeroes in this table indicate that no radioactivity was present at detectable levels.
      • N/A - Errors in measurements are not reported for these values since none were identified during the reporting period.

El-11

2004 WATTS BAR NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT TABLE 4-A Gaseous Effluents-Grounrd Level Releases Unit: 1 Starting: 1-Jan-2004 Ending: 30-Jun-2004 Continuous Mode Batch Mode Quarter I Quarter 2 Quarter I Quarter 2 Nuclides Released Unit Fission Gases Kr-85m Xe-131m Kr-85 Xe-135 Xe-133m Ar-41 Xe-133 Ci O.OOE+00 Ci O.OOE+00 Ci O.OOE+00 Ci 1.00E+00 Ci O.OOE+00 Ci O.OOE+00 Ci 2.16E+00 1.63E-02 O.OOE+00 O.OOE+00 1.44E-01 O.OOE+00 O.OOE+00 5.83E+00 2.56E-02 1.96E+00 1.33E+00 1.35E+00 1.51 E+00 4.94E+00 1.33E+02 2.53E-02 6.54E-01 7.08E-01 1.52E+00 2.42E+00 4.67E+00 1.67E+02 1.77E+02 Total Ci 3.16E+00 5.99E+00 1.45E+02 lodines 1-131 Ci 8.53E-06 7.78E-10 O.OOE+00 O.OOE+00 1-133 Ci 1.98E-06 1.02E-09 O.OOE+00 O.OOE+00 Total Ci 1.05E-05 1.80E-09 O.OOE+00 O.OOE+00 Particulates Cs-134 Ci O.OOE+00 1.40E-10 O.OOE+00 O.OOE+00 Rb-88 Ci O.OOE+00 1.43E-07 O.OOE+00 O.OOE+00 Ba-139 Ci O.OOE+00 4.24E-07 O.OOE+00 O.OOE+00 Br-82 Ci 1.52E-06 2.12E-06 O.OOE+00 O.OOE+00 Cs-1 38 Ci O.OOE+00 6.42E-06 O.OOE+00 O.OOE+00 Total Ci 1.52E-06 9.11 E-06 O.OOE+00 O.OOE+00 H-3 Ci 3.13E+00 2.36E+00 6.80E-01 O.OOE+00

  • Zeroes in this table indicate that no radioactivity was present at detectable levels.

El-12

2004 WATTS BAR NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT TABLE 4-B Gaseous Effluents-Ground Level Releases Unit: 1 Starting: 1-Jul-2004 Ending: 31-Dec-2004 Continuou! s Mode Batch Mode Quarter 4 Quarter 3 Quarter 4 Nuclides Released Unit Quarter 3 Fission Gases Kr-88 Xe-138 Xe-135m Kr-87 Kr-85m Kr-85 Xe-135 Xe-131m Xe-133m Ar-41 Xe-1 33 Ci O.OOE+00*

Ci 0.OOE+00 Ci 6.07E-04 Ci 7.38E-06 Ci 1.64E-04 Ci 0.OOE+00 Ci 3.99E-03 Ci O.OOE+O0 Ci 0.00E+00 Ci 0.OOE+00 Ci 1.1IiE-02 2.09E-03 3.55E-03 7.05E-03 2.21 E-03 1.23E-03 O.OOE+O0 2.06E+00 O.OOE+00 O.OOE+OO 3.19E-04 4.45E+00 O.OOE+00 O.OOE+00 O.OOE+00 1.65E-02 6.17E-02 1.32E+00 3.23E+00 1.90E+00 3.65E+00 9.82E+00 2.64E+02 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 7.08E-03 1.18E+00 2.68E+00 4.12E+00 4.21 E+00 6.09E+00 3.37E+02 3.55E+02 Total Ci 1.59E-02 6.53E+00 2.84E+02 lodines 1-134 Ci 0.OOE+00 5.09E-08 O.OOE+00 O.OOE+00 1-132 Ci 2.56E-08 1.54E-07 O.OOE+00 O.OOE+00 1-131 Ci 4.18E-06 2.20E-07 O.OOE+00 O.OOE+00 1-133 Ci 1.71 E-06 3.78E-07 O.OOE+00 O.OOE+00 1-135 Ci 2.97E-08 3.79E-07 O.OOE+00 O.OOE+00 Total Ci 5.95E-06 1.1 8E-06 O.OOE+00 O.OOE+00 Particulates Nb-97 Ci 7.02E-08 O.OOE+00 O.OOE+00 O.OOE+00 Co-58 Ci 2.02E-06 O.OOE+00 O.OOE+00 O.OOE+00 Sr-89 Ci O.OOE+00 1.64E-09 O.OOE+00 O.OOE+00 Rb89 Ci O.OOE+00 1.09E-08 O.OOE+00 O.OOE+00 Co-57 Ci O.OOE+00 1.53E-08 O.OOE+00 O.OOE+00 Co-60 Ci 1.52E-05 3.15E-06 O.OOE+00 O.OOE+00 Ba-139 Ci 1.87E-06 4.79E-06 O.OOE+O0 O.OOE+00 Rb-88 Ci 3.06E-06 6.18E-06 O.OOE+00 O.OOE+00 Br-82 Ci 3.61 E-06 1.01 E-05 O.OOE+00 O.OOE+00 Cs-138 Ci 5.38E-05 1.49E-04 0.OOE+00 O.OOE+00 Total Ci 7.97E-05 1.73E-04 O.OOE+OO O.OOE+00 H-3 Ci 4.07E+00 3.66E+00 0.OOE+00 O.OOE+00

  • Zeroes in this table indicate that no radioactivity was present at detectable levels.

El-13

2004 WATTS BAR NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT TABLE 5-A SOLID WASTE (RADIOACTIVE SHIPMENTS)

A. Solid Waste Shipped Offsite for Burial or Disposal (not Irradiated Fuel)

1. Type of Waste
a. Spent resins, filter sludges, evaporator bottoms, etc.
b. Dry Active Waste, Compressible Waste Contaminated Equipment, etc.
c. Irradiated Components, Control Rods, etc.

12 Month Unit Period m3 17.0 Ci 212 m3 72.0 Ci 0.290 m3 None Ci None Est. (Ci)

Error %

N/A

+I-25%

N/A

+/-25%

N/A N/A El-14

2004 WATTS BAR NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT

2. Estimate of Maior Nuclide Composition (by type of waste)

Percent Ci

a. Spent resins, filter sludges, evaporator bottoms, etc.

(nuclides determined by measurement)

H-3 0.425 9.02E-1 Be-7 0.025 5.24E-2 C-14 0.142 3.01 E-1 Cr-51 0.613 1.30E+O Mn-54 2.975 6.31 E+O Fe-55 30.792 6.53E+1 Fe-59 0.108 2.29E-1 Co-57 0.242 5.14E-1 Co-58 12.710 2.70E+1 Co-60 11.948 2.54E+1 Ni-59 0.305 6.48E-1 Ni-63 37.687 8.00E+1 Zn-65 0.057 1.22E-1 Sr-89 0.000 6.09E-4 Sr-90 0.002 3.53E-3 Zr-95 0.461 9.77E-1 Nb-95 0.528 1.12E+O Ag-110m 0.020 4.26E-2 Cd-109 0.050 1.07E-1 Sn-117m 0.000 8.60E-6 Sn-1 13 0.036 7.62E-2 Sb-124 0.054 1.15E-1 Sb-125 0.473 1.OOE+O Cs-134 0.126 2.68E-1 Cs-137 0.182 3.86E-1 Ce-144 0.034 7.24E-2 Pu-238 0.000 5.30E-5 Pu-239 0.000 1.66E-5 Pu-240 0.000 1.66E-5 Pu-241 0.003 6.88E-3 E1-15

2004 WATTS BAR NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT TABLE 5-A SOLID WASTE (RADIOACTIVE SHIPMENTS)

b. Dry active waste, compressible waste, contaminated equipment, etc. (nuclides determined by estimate)

H-3 Cr-51 Mn-54 Fe-55 Fe-59 Co-57 Co-58 Co-60 Ni-63 Zn-65 Zr-95 Nb-95 Ag-1 Om Sn-113 Sb-125 Cs-1 37 Ce-1 44 Percent 1.106 0.989 3.236 48.591 0.254 0.151 18.627 8.662 15.246 0.067 0.810 1.546 0.017 0.057 0.567 0.025 0.049 Ci 3.21 E-3 2.87E-3 9.39E-3 1.41 E-1 7.36E-4 4.39E-4 5.40E-2 2.51 E-2 4.42E-2 1.93E-4 2.35E-3 4.49E-3 4.97E-5 1.66E-4 1.64E-3 7.28E-5 1.43E-4

c. Irradiated Components N/A N/A El-16

2004 WATTS BAR NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT TABLE 5-B SOLID WASTE (RADIOACTIVE SHIPMENTS)

3. Solid Waste Disposition Number of Shipments 5

1 1

Mode of Transportation Motor Freight Motor Freight Motor Freight Destination Barnwell Waste Mgmt Facility Duratek DAW Processing Duratek Green is Clean

4. Irradiated Fuel Shipments (Disposition)

Number of Shipments Type Quantity None N/A

5. Solidification of Waste Was solidification performed?

No If yes, solidification media:

N/A Mode of Transportation N/A Destination N/A El-17

2004 WATTS BAR NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT Radiological Impact Introduction Potential doses to maximum individuals and the population around Watts Bar are calculated for each quarter as required in Section 5.2 of the Offsite Dose Calculation Manual (ODCM).

Measured plant releases for the reporting period are used to estimate these doses. Dispersion of radioactive effluents in the environment is estimated using meteorological data and riverflow data measured during the period. In this report, the doses resulting from releases are described and compared to limits established for Watts Bar.

Dose Limits The ODCM specifies limits for the release of radioactive effluents, as well as limits for doses to the general public from the release of radioactive effluents. These limits are set well below the Technical Specification limits which govern the concentrations of radioactivity and doses permissible in unrestricted areas. This ensures that radioactive effluent releases are As Low As Reasonably Achievable.

Dose Calculations Estimated doses to the public are determined using computer models (the Gaseous Effluent Licensing Code, GELC, and the Quarterly Water Dose Assessment Code, QWATA). These models are based on guidance provided by the NRC (in Regulatory Guides 1.109, 1.111 and 1.1 13) for determining the potential dose to individuals and populations living in the vicinity of the plant. The area around the plant is analyzed to determine the pathways through which the public may receive a dose. The doses calculated are a representation of the dose to a "maximum exposed individual."

Some of the factors used in these calculations (such as ingestion rates) are maximum values.

Many of these factors are obtained from NUREG/CR-1004. The values chosen will tend to overestimate the dose to this "maximum" person.

The expected dose to actual individuals is lower. The calculated doses are presented in Tables 6A, 6B, 7A and 7B.

Doses From Airborne Effluents For airborne effluents, the public can be exposed to radiation from several sources: direct radiation from the radioactivity in the air, direct radiation from radioactivity deposited on the ground, inhalation of airborne radioactivity, ingestion of vegetation which contains radioactivity deposited from the atmosphere, and ingestion of milk and beef which contains radioactivity deposited from the atmosphere onto vegetation and subsequently eaten by milk and beef animals.

Airborne Discharge Points All releases from Watts Bar are considered ground-level releases.

The ground-level Joint Frequency Distribution (JFD) is derived from wind speeds and directions measured 10 meters above ground and from the vertical temperature difference between 10 and 46 meters, and are presented for each quarter on pages EI-25 through El-52.

El-18

2004 WATTS BAR NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT Radiological Impact Meteorological Data Meteorological variables at Watts Bar are measured continuously. Measurements collected include wind speed, wind direction, and temperature at heights of 10, 46, and 91 meters above the ground. Quarterly joint frequency distributions (JFDs) are calculated for each release point using the appropriate levels of meteorological data. A joint frequency distribution gives the percentage of the time in a quarter that the wind is blowing out of a particular upwind compass sector in a particular range of wind speeds for a given stability class A through G. The wind speeds are divided into nine wind speed ranges.

Calms are distributed by direction in proportion to the distribution of non-calm wind directions less than 0.7 m/s (1.5 mph). Stability classes are determined from the vertical temperature difference between two measurement levels.

Extemal Exposure Dose Dose estimates for maximum external air dose (gamma-air and beta-air doses) are made for points at and beyond the unrestricted area boundary as described in the Watts Bar ODCM. The highest of these doses is then selected.

Submersion Dose External doses to the skin and total body, due to submersion in a cloud of noble gases, are estimated for the nearest residence in each sector. The residence with the highest dose is then selected from all sectors.

Organ Dose Doses to organs due to releases of airborne effluents are estimated for the inhalation, ground contamination, and ingestion pathways.

The ingestion pathway is further divided into four possible contributing pathways: ingestion of cow/goat milk, ingestion of beef, and ingestion of vegetables. Doses from applicable pathways are calculated for each real receptor location identified in the most recent land use survey. To determine the maximum organ dose, the doses from the pathways are summed for each receptor. For the ingestion dose, however, only those pathways that exist for each receptor are considered in the sum, i.e., milk ingestion doses are included only for locations where milk is consumed without commercial preparation and vegetable ingestion is included only for those locations where a garden is identified. To conservatively account for beef ingestion, a beef ingestion dose equal to that for the highest unrestricted area boundary location is added to each identified receptor. For ground contamination, the dose added to the organ dose being calculated is the total body dose calculated for that location, i.e., it is assumed that the dose to an individual organ is equal to the total body dose.

Doses from airborne effluents are presented in Tables 6A and 6B.

Doses From Liquid Effluents For liquid effluents, the public can be exposed to radiation from three sources: the ingestion of water from the Tennessee River, the ingestion of fish caught in the Tennessee River, and direct exposure from radioactive material deposited on the river shoreline sediment (recreation).

El-19

2004 WATTS BAR NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT Radiological Impact The concentrations of radioactivity in the Tennessee River are estimated by a computer model which uses measured hydraulic data downstream of Watts Bar. Parameters used to determine the doses are based on guidance given by the NRC (in Regulatory Guide 1.109) for maximum ingestion rates, exposure times, etc.

Wherever possible, parameters used in the dose calculation are site specific use factors determined by TVA. The models that are used to estimate doses, as well as the parameters input to the models, are described in detail in the Watts Bar ODCM.

Liquid Release Points and River Data Radioactivity concentrations in the Tennessee River are calculated assuming that releases in liquid effluents are continuous. All routine liquid releases from Watts Bar, located at Tennessee River Mile 528.5, are made through diffusers which extend into the Tennessee River. It is assumed that releases to the river through these diffusers will initially be entrained in one-tenth of the water which flows past the plant. The QWATA code makes the assumption that this mixing condition holds true until the water is completely mixed at Tennessee River Mile 510.0.

Doses are calculated for locations within a 50 mile radius downstream of the plant site. The maximum potential recreation dose is calculated for a location immediately downstream from the plant outfall. The maximum individual dose from ingestion of fish is assumed to be that calculated for the consumption of fish caught anywhere between the plant and the first downstream dam (Chickamauga Dam). The maximum individual dose from drinking water is assumed to be that calculated at the nearest downstream public water supply (Dayton, TN). This could be interpreted as indicating that the maximum individual, as assumed for liquid releases from Watts Bar, is an individual who obtains all of his drinking water at Dayton, TN, consumes fish caught from the Tennessee River between Watts Bar and Chickamauga Dam, and spends 500 hours0.00579 days <br />0.139 hours <br />8.267196e-4 weeks <br />1.9025e-4 months <br /> per year on the shoreline just below the outfall from Wafts Bar. Dose estimates for the maximum individual due to liquid effluents for each quarter in the period are presented in Tables 7A and 7B, along with the average river flows past the plant site for the periods.

Population Doses Population doses for highest exposed organ due to airborne effluents are calculated for an estimated 1,066,600 persons living within a 50-mile radius of the plant site. Doses from external pathways and inhalation are based on the 50-mile human population distribution.

Ingestion population doses are calculated assuming that each individual consumes milk, vegetables, and meat produced within the sector annulus in which he resides. Doses from external pathways and inhalation are based on the 50-mile human population distribution.

Population doses for total body and the maximum exposed organ due to liquid effluents are calculated for the entire downstream Tennessee River Population. Water ingestion population doses are calculated using actual population figures for downstream public water supplies.

Fish ingestion population doses are calculated assuming that all sport fish caught in the Tennessee River are consumed by the Tennessee River population. Recreation population doses are calculated using actual recreational data on the number of shoreline visits at downstream locations.

Population dose estimates for airborne and liquid effluents are presented in Tables 6A, 6B, 7A and 7B.

El-20

2004 WATTS BAR NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT Radiological Impact Direct Radiation External gamma radiation levels were measured by thermoluminescent dosimeters (TLDs) deployed around WBN as part of the offsite Environmental Radiological Monitoring Program. The quarterly gamma radiation levels determined from these TLDs during this reporting period averaged 16.5 mR/quarter at onsite (at or near the site boundary) stations and 15.25 mR/quarter at offsite stations or 1.25 mR/quarter higher onsite than at offsite stations. This difference is consistent with levels measured for preoperation and construction phases of the WBN plant site where the average radiation levels onsite were generally 2-6 mR/quarter higher than the levels offsite. This may be attributable to natural variations in environmental radiation levels, earth moving activities onsite, the mass of concrete employed in the construction of the plants, or other undetermined influences. Fluctuations in natural background dose rates and in TLD readings tend to mask any small increments which may be due to plant operations. Thus, there was no identifiable increase in dose rate levels attributable to direct radiation from plant equipment and/or gaseous effluents.

Dose To A Member Of The Public Inside The Unrestricted Area Boundary As stated in the Watts Bar Offsite Dose Calculation Manual, an evaluation of the dose to a member of the public inside the unrestricted area boundary is performed for a hypothetical TVA employee who works just outside the restricted area boundary for an entire work year (2000 hours0.0231 days <br />0.556 hours <br />0.00331 weeks <br />7.61e-4 months <br />).

Results from onsite TLD measurements indicated that the highest onsite TLD reading outside the Radiological Control Area was 209 mrem. Using this value, subtracting an annual background value of approximately 61 mrem/year (see previous section), and multiplying by the ratio of the occupancy times (2000/8760), the highest external dose to a member of the public inside the unrestricted area boundary would be 33.79 mrem. The doses due to radioactive effluents released to the atmosphere calculated in this report would not add a significant amount to this measured dose. This dose is well below the 10 CFR 20 annual limit of 100 mrem.

Total Dose To determine compliance with 40 CFR 190, annual total dose contributions to the maximum individual from Watts Bar radioactive effluents and all other nearby uranium fuel cycle sources are considered.

The annual dose to any organ other than thyroid for the maximum individual is conservatively estimated by summing the following doses: the total body air submersion dose for each quarter, the critical organ dose (for any organ other than the thyroid) from airborne effluents for each quarter from ground contamination, inhalation and ingestion, the total body dose from liquid effluents for each quarter, the maximum organ dose (for any organ other than the thyroid) from liquid effluents for each quarter, and any identifiable increase in direct radiation dose levels as measured by the environmental monitoring program. This dose is compared to the 40 CFR 190 limit for total body or any organ dose (other than thyroid) to determine compliance.

The annual thyroid dose to the maximum individual is conservatively estimated by summing the following doses: the total body air submersion dose for each quarter, the thyroid dose from airborne effluents for each quarter, the total body dose from liquid effluents for each quarter, the thyroid dose from liquid effluents for each quarter, and any identifiable increase in direct radiation dose levels as measured by the environmental monitoring program.

This dose is compared to the 40 CFR 190 limit for thyroid dose to determine compliance. Cumulative annual total doses are presented in Table 8.

El-21

2004 WATTS BAR NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT TABLE 6-A Doses from Airborne Effluents First Quarter Individual Doses Pathway Dose Quarterly Percent of Location Limit Limit External Gamma Air 2.96E-02 mrad 5 mrad

< 1%

ENE/1370 meters Beta Air 5.61 E-02 mrad 10 mrad

<1%

ENE/1370 meters Submersion i

Total Body 1.24E-02 mrem N/A N/A ENE/2414 meters Skin 2.52E-02 mrem N/A N/A SE/1372 meters Organ Doses Child/Thyroid 7.56E-03 mrem 7.5 mrem

< 1%

NE/3829 meters Child/Total Body 7.52E-03 mrem 7.5 mrem

< 1%

NE/3829 meters Population Doses Total Body Dose 2.94E-02 man-rem Maximum Organ Dose (organ) 2.96E-02 man-rem (thyroid)

Second Quarter Individual Doses Pathway Dose Quarterly Percent of Location Limit Limit External Gamma Air 4.34E-02 mrad 5 mrad

< 1 %

E/1280 meters Beta Air 8.98E-02mrad 10 mrad

< 1%

E/1280 meters Submersion Total Body 1.79E-02 mrem N/A N/A ENE/2414 meters Skin 3.79E-02 mrem N/A N/A ENE/2414 meters Organ Doses I

I II Child/Thyroid 1.06E-02 mrem 7.5 mrem

< 1°%

NE/3829 meters Child/Total Body 1.06E-02 mrem 7.5 mrem

< 1%

NE/3829 meters Population Doses Total Body Dose Maximum Organ Dose (organ) 3.27E-02 man-rem 3.27E-02 man-rem (thyroid)

Population doses can be compared to the natural background dose for the entire 50-mile population of about 150,000 man-rem/year (based on 140 mrem/yr for natural background).

E1-22

2004 WATTS BAR NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT TABLE 6-B Doses from Airborne Effluents Third Quarter Individual Doses Pathway Dose Quarterly Percent of Location Limit Limit External Gamma Air 1.02E-02 mrad 5 mrad

<1 %

ESE/1250 meters Beta Air 4.08E-03 mrad 10 mrad

<1%

ESE/1250 meters Submersion Total Body 6.31 E-03 mrem N/A N/A SE/1372 meters Skin 9.40E-03 mrem N/A N/A SE/1372 meters Organ Doses I

I I

Child/Thyroid 2.71 E-02 mrem 7.5 mrem

<1%

WSW/1829 meters Child/Total Body 2.70E-02 mrem 7.5 mrem

<1%

WSW/1829 meters Population Doses Total Body Dose 1.31E-01 man-rem Maximum Organ Dose (organ) 1.32E-01 man-rem (thyroid)

Fourth Quarter Individual Doses Pathway Dose Quarterly Percent of Location Limit Limit External Gamma Air 9.22E-02 mrad 5 mrad

<1%

E/1280 meters Beta Air 2.10E-01 mrad 10 mrad

<1%

E/1280 meters Submersion Total Body 3.12E-02 mrem N/A N/A SE/1372 meters Skin 6.74E-02 mrem N/A N/A SE/1372 meters Organ Doses Child/Thyroid 1.22E-02 mrem 7.5 mrem

< 1%

NE/3829 meters Child/Total Body 1.22E-02 mrem 7.5 mrem

<1%

NE/3829 meters Population Doses Total Body Dose Maximum Organ Dose (organ) 6.04E-02 man-rem 6.04E-02 man-rem (thyroid)

Population doses can be compared to the natural background dose for the entire 50-mile population of about 150,000 man-rem/year (based on 140 mrem/yrfornatural background).

El-23

2004 WATTS BAR NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT TABLE 7-A Doses from Liquid Effluents First Quarter Individual Doses (mrem)

Age Group Organ Dose Quarterly Limit Percent of Limit Child Total Body 1.3E-04 1.5 mrem

< 1 %

Adult GIT 1.5E-04 5 mrem

< I %

Child Thyroid 1.3E-04 5 mrem

< 1 %

Average Riverfiow past WBN (cubic feet per second): 33,651 PoDulation Doses Total Body Dose 4.6E-03 man-rem Maximum Organ Dose (organ) 4.8E-03 man-rem (GIT)

Second Quarter Individual Doses (mrem)

Age Group Organ Dose Quarterly Limit Percent of Limit Child Total Body 3.3E-04 1.5 mrem

< 1 %

Adult GIT 5.6E-04 5 mrem

< 1 %

Child Thyroid 3.1E-04 5 mrem<1 Average Riverflow past WBN (cubic feet per second): 13,797 Population Doses Total Body Dose 9.2E-03 man-rem Maximum Organ Dose (organ) 9.6E-03 man-rem (GIT)

Population doses can be compared to the natural background dose for the entire 50-mile population of about 150,000 man-rem/year (based on 140 mrem/yr for natural background).

El-24

2004 WATTS BAR NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT TABLE 7-B Doses from Liquid Effluents Third Quarter Individual Doses (mrem)

Age Group Organ Dose Quarterly Limit Percent of Limit Child Total Body 1.3E-03 1.5 mrem

< I %

Child GIT 1.3E-03 5 mrem

< 1 %

Child Thyroid 1.3E-03 5 mrem

< 1 %

Average Riverflow past WBN (cubic feet per second): 31,454 Population Doses Total Body Dose 6.7E-02 man-rem Maximum Organ Dose (organ) 6.8E-02 man-rem (GIT)

Fourth Quarter Individual Doses (mrem)

Age Group Organ Dose Quarterly Limit Percent of Limit Child Total Body 1.2E-03 1.5 mrem

< 1 %

Child Bone 1.3E-03 5 mrem

< 1 %

Child Thyroid 1.4E-03 5 mrem

< 1 %

Average Riverflow past WBN (cubic feet per second): 51,922 Population Doses Total Body Dose 7.4E-02 man-rem Maximum Organ Dose (organ) 7.6E-02 man-rem (Thyroid)

Population doses can be compared to the natural background dose for the entire 50-mile population of about 150,000 man-rem/year (based on 140 mrem/yrfornaturalbackground).

EI-25

2004 WATTS BAR NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT TABLE 8 Total Dose from Fuel Cycle First Second l Third l

Fourth Dose Quarter l Quarter l Quarter l Quarter l Total Body or any Organ (cept thyroid Total body air submersion 1.24E-02 1.79E-02 9.40E-03 3.12E-02 Critical organ dose (air) 7.52E-03 1.06E-02 2.70E-02 1.22E-02 Total body dose (liquid) 1.30E-04 3.30E-04 1.30E-03 1.20E-03 Maximum organ dose (liquid) 1.50E-04 5.60E-04 1.30E-03 1.30E-03 Direct Radiation Dose O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Total 2.02E-02 2.94E.02 5.65E-02 4.54E-02 Cumulative Total Dose (mrem) 1.51E-O1 Annual Dose Limit (mrem) 25 Percent of Limit 0.60%

Thyroid Total body air submersion 1.24E-02 1.79E-02 9.40E-03 3.12E-02 Thyroid dose (airborne) 7.56E-03 1.06E-02 2.71 E-02 1.22E-02 Total body dose (liquid) 1.30E-04 3.30E-04 1.30E-03 1.20E-03 Thyroid dose (liquid) 1.30E-04 3.1 OE-04 1.30E-03 1.40E-03 Direct Radiation Dose O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Total 2.02E-02 2.98E-02 5.65E-02 4.55E-02 Cumulative Total Dose (mrem) 1.52E-01 Annual Dose Limit (mrem) 75 Percent of Limit 0.20%

El-26

2004 WATTS BAR NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

Watts Bar Nuclear Plant JAN 1, 2004 -

MAR 31, 2004 WIND WIND SPEED(MPH)

DIRECTION CALM 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>.24.5 TOTAL N

0.000 0.000 0.000 0.000 0.047 0.094 0.187 0.000 0.000 0.328 NNE 0.000 0.000 0.000 0.000 0.047 0.187 0.000 0.000 0.000 0.234 NE 0.000 0.000 0.000 0.000 0.094 0.047 0.000 0.000 0.000 0.141 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E

0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.047 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SE 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.047 SSE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 S

0.000 0.000 0.000 0.000 0.047 0.187 0.000 0.000 0.000 0.234 SSW 0.000 0.000 0.000 0.000 0.281 1.172 0.000 0.000.

0.000 1.453 SW 0.000 0.000 0.000 0.000 0.047 0.047 0.000 0.000 0.000 0.094 WSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 W

0.000 0.000 0.000 0.000 0.000 0.094 0.000 0.000 0.000 0.094 WhW 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.047 NW 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.047 NMN 0.000 0.000 0.000 0.000 0.094 0.000 0.141 0.000 0.000 0.234 SUBTOTAL 0.000 0.000 0.047 0.047 0.656 1.921 0.328 0.000 0.000 2.999 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2135 TOTAL HOURS OF STABILITY CLASS A 64 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A 64 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2134 TOTAL HOURS CALM 0

METEOROLOGICAL FACILITY:

Watts Bar Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 9.51 AND 45.63 METERS WIND SPEED AND DIRECTION MEASURED AT 9.72 METER LEVEL DATE PRINTED: 2004/05/10 MEAN WIND SPEED =

9.10 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS El-27

2004 WATTS BAR NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<--l.7 C/100 M)

Watts Bar Nuclear Plant JAN 1, 2004 -

MAR 31, 2004 WIND WIND SPEED(MPH)

DIRECTION CALM 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

0.000 0.000 0.000 0.000 0.141 0.187 0.000 0.000 0.000 0.328 NNE 0.000 0.000 0.000 0.047 0.094 0.281 0.047 0.000 0.000 0.469 NE 0.000 0.000 0.000 0.141 0.000 0.047 0.000 0.000 0.000 0.187 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E

0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SSE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 S

0.000 0.000 0.000 0.000 0.094 0.000 0.000 0.000 0.000 0.094 SSW 0.000 0.000 0.000 0.094 0.234 0.328 0.000 0.000 0.000 0.656 SW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WSW 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.047 W

0.000 0.000 0.000 0.000 0.000 0.094 0.000 0.000 0.000 0.094 WN1%

0.000 0.000 0.000 0.000 0.000 0.094 0.000 0.000 0.000 0.094 NW 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.047 NNW 0.000 0.000 0.000 0.047 0.000 0.047 0.047 0.000 0.000 0.141 SUBTOTAL 0.000 0.000 0.000 0.328 0.562 1.172 0.094 0.000 0.000 2.156 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2135 TOTAL HOURS OF STABILITY CLASS B 46 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B 46 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2134 TOTAL HOURS CALM 0

METEOROLOGICAL FACILITY:

Watts Bar Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 9.51 AND 45.63 METERS WIND SPEED AND DIRECTION MEASURED AT 9.72 METER LEVEL DATE PRINTED: 2004/05/10 MEAN WIND SPEED =

8.02 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS El-28

2004 WATTS BAR NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<--1.5 C/100 M)

Watts Bar Nuclear Plant JAN 1, 2004 - MAR 31, 2004 WIND WIND SPEED(MPH)

DIRECTION CALM 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

0.000 0.000 0.000 0.234 0.000 0.187 0.000 0.000 0.000 0.422 NNE 0.000 0.000 0.047 0.141 0.328 0.187 0.000 0.000 0.000 0.703 NE 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.047 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E

0.000 0.000 0.000 0.094 0.047 0.000 0.000 0.000 0.000 0.141 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SE 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.047 SSE 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.047 S

0.000 0.000 0.000 0.047 0.047 0.047 0.000 0.000 0.000 0.141 SSW 0.000 0.000 0.000 0.000 0.234 0.281 0.000 0.000 0.000 0.515 SW 0.000 0.000 0.000 0.000 0.141 0.000 0.000 0.000 0.000 0.141 WSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 W

0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.047 WNW 0.000 0.000 0.000 0.000 0.047 0.328 0.000 0.000 0.000 0.375 NW 0.000 0.000 0.000 0.000 0.047 0.094 0.047 0.000 0.000 0.187 NNM 0.000 0.000 0.000 0.000 0.000 0.094 0.047 0.000 0.000 0.141 SUBTOTAL 0.000 0.000 0.047 0.609 0.937 1.265 0.094 0.000 0.000 2.952 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2135 TOTAL HOURS OF STABILITY CLASS C 63 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C 63 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2134 TOTAL HOURS CALM 0

METEOROLOGICAL FACILITY:

Watts Bar Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 9.51 AND 45.63 METERS WIND SPEED AND DIRECTION MEASURED AT 9.72 METER LEVEL DATE PRINTED: 2004/05/10 MEAN WIND SPEED =

7.50 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS El-29

2004 WATTS BAR NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<.-0.5 C/100 M)

Watts Bar Nuclear Plant JAN 1. 2004 - MAR 31. 2004 WIND WIND SPEED(MPH)

DIRECTION CALM 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>x24.5 TOTAL N

0.000 0.047 0.562 1.312 1.125 1.546 0.094 0.000 0.000 4.686 NNE 0.000 0.000 0.797 1.265 1.546 2.109 0.469 0.000 0.000 6.186 NE 0.000 0.094 0.469 0.656 0.234 0.094 0.000 0.000 0.000 1.546 ENE 0.000 0.000 0.562 0.187 0.328 0.094 0.000 0.000 0.000 1.172 E

0.000 0.047 0.234 0.094 0.047 0.000 0.000 0.000 0.000 0.422 ESE 0.000 0.000 0.047 0.047 0.000 0.000 0.000 0.000 0.000 0.094 SE 0.000 0.047 0.234 0.000 0.000 0.000 0.000 0.000 0.000 0.281 SSE 0.000 0.047 0.469 0.187 0.047 0.000 0.000 0.000 0.000 0.750 S

0.000 0.000 0.750 0.562 0.422 0.375 0.141 0.000 0.000 2.249 SSW 0.000 0.000 0.937 1.874 1.828 1.359 0.094 0.000 0.000 6.092 SW 0.000 0.047 0.515 1.078 0.750 0.094 0.000 0.000 0.000 2.484 WSW 0.000 0.047 0.515 0.422 0.141 0.094 0.000 0.000 0.000 1.218 W

0.000 0.141 0.469 0.281 0.797 1.172 0.000 0.000 0.000 2.858 WNik 0.000 0.000 0.328 0.562 1.312 0.843 0.000 0.000 0.000 3.046 NW 0.000 0.000 0.422 0.234 1.078 1.031 0.047 0.000 0.000 2.812 NNWI 0.000 0.000 0.562 0.469 0.984 2.249 0.141 0.000 0.000 4.405 SUBTOTAL 0.000 0.515 7.873 9.231 10.637 11.059 0.984 0.000 0.000 40.300 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2135 TOTAL HOURS OF STABILITY CLASS D 861 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D 860 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2134 TOTAL HOURS CALM 0

METEOROLOGICAL FACILITY:

Watts Bar Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 9.51 AND 45.63 METERS WIND SPEED AND DIRECTION MEASURED AT 9.72 METER LEVEL DATE PRINTED: 2004/05/10 MEAN WIND SPEED

  • 6.10 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS El-30

2004 WATTS BAR NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

Watts Bar Nuclear Plant JAN 1. 2004 - MAR 31, 2004 WIND SPEED(MPH)

CALM 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 WIND DIRECTION

>-24.5 TOTAL N

0.000 NNE 0.000 NE 0.000 ENE 0.000 E

0.000 ESE 0.000 SE 0.000 SSE 0.000 S

0.000 SSW 0.000 SW 0.000 WSW 0.000 W

0.000 W1NW 0.000 NW 0.000 NNW 0.000 0.094 0.890 0.843 0.515 0.141 0.000 0.000 0.000 0.750 0.515 0.141 0.187 0.047 0.000 0.234 0.703 0.422 0.422 0.141 0.000 0.000 0.047 0.797 0.187 0.000 0.000 0.000 0.000 0.094 0.422 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.141 0.000 0.000 0.000 0.000 0.000 0.000 0.141 0.187 0.000 0.000 0.000 0.000 0.000 0.234 0.609 0.141 0.422 0.328 0.047 0.000 0.187 1.406 1.734 1.734 1.828 0.094 0.000 0.141 1.781 0.562 0.281 0.094 0.000 0.000 0.281 0.937 0.141 0.187 0.000 0.000 0.000 0.328 0.703 0.281 0.375 0.000 0.000 0.000 0.375 0.328 0.375 0.422 0.141 0.000 0.000 0.094 0.797 0.562 0.281 0.375 0.094 0.000 0.141 0.656 0.422 0.328 0.281 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2.484 1.640 1.921 1.031 0.562 0.000 0.141 0.328 1.781 6.982 2.858 1.546 1.687 1.640 2.202 1.828 SUBTOTAL 0.000 2.530 10.965 6.232 5.108 3.515 0.281 0.000 0.000 28.632 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS E TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS TOTAL HOURS CALM METEOROLOGICAL FACILITY:

Watts Bar Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 9.51 AND 45.63 METERS WIND SPEED AND DIRECTION MEASURED AT 9.72 METER LEVEL MEAN WIND SPEED

  • 4.43 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS 2135 611 611 2134 0

DATE PRINTED: 2004/05/10 EI-31

2004 WATTS BAR NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<- 4.0 C/100 M)

Watts Bar Nuclear Plant JAN 1, 2004 -

MAR 31, 2004 WIND SPEED(MPH)

CALM 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 WIND DIRECTION

>.24.5 TOTAL N

0.000 NNE 0.000 NE 0.000 ENE 0.000 E

0.000 ESE 0.000 SE 0.000 SSE 0.000 S

0.000 SSW 0.000 SW 0.000 WSW 0.000 W

0.000 WNW 0.000 NW 0.000 NNW 0.000 0.234 0.094 0.000 0.000 0.000 0.000 0.000 0.094 0.328 0.047 0.000 0.000 0.000 0.000 0.141 0.469 0.000 0.000 0.000 0.000 0.000 0.047 0.328 0.094 0.000 0.000 0.000 0.000 0.094 0.141 0.047 0.000 0.000 0.000 0.000 0.187 0.000 0.000 0.000 0.000 0.000 0.000 0.094 0.047 0.000 0.000 0.000 0.000 0.000 0.141 0.000 0.047 0.000 0.000 0.000 0.000 0.094 0.141 0.141 0.000 0.000 0.000 0.000 0.281 0.375 0.281 0.047 0.000 0.000 0.000 0.469 0.656 0.047 0.000 0.000 0.000 0.000 0.703 1.031 0.000 0.000 0.000 0.000 0.000 0.703 0.656 0.047 0.000 0.000 0.000 0.000 0.562 0.422 0.000 0.000 0.000 0.000 0.000 0.609 0.422 0.094 0.000 0.000 0.000 0.000 0.234 0.375 0.094 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.328 0.469 0.609 0.469 0.281 0.187 0.141 0.187 0.375 0.984 1.172 1.734 1.406 0.984 1.125 0.703 SUBTOTAL 0.000 4.686 5.483 0.937 0.047 0.000 0.000 0.000 0.000 11.153 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS F TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS TOTAL HOURS CALM METEOROLOGICAL FACILITY:

Watts Bar Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 9.51 AND 45.63 METERS WIND SPEED AND DIRECTION MEASURED AT 9.72 METER LEVEL MEAN WIND SPEED =

1.88 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS 2135 238 238 2134 0

DATE PRINTED: 2004/05/10 El-32

2004 WATTS BAR NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

Watts Bar Nuclear Plant JAN 1, 2004 -

MAR 31, 2004 WIND WIND SPEED(MPH)

DIRECTION CALM 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 16.5-24.4

>.24.5 TOTAL N

0.005 0.167 0.234 0.047 0.000 0.000 0.000 0.000 0.000 0.474 NNE 0.002 0.047 0.141 0.000 0.000 0.000 0.000 0.000 0.000 0.190 NE 0.006 0.422 0.094 0.000 0.000 0.000 0.000 0.000 0.000 0.522 ENE 0.007 0.234 0.328 0.000 0.000 0.000 0.000 0.000 0.000 0.569 E

0.005 0.234 0.141 0.000 0.000 0.000 0.000 0.000 0.000 0.379 ESE 0.001 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 SE 0.004 0.328 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.332 SSE 0.003 0.141 0.094 0.000 0.000 0.000 0.000 0.000 0.000 0.237 S

0.010 0.703 0.094 0.000 0.000 0.000 0.000 0.000 0.000 0.806 SSW 0.011 0.703 0.234 0.000 0.000 0.000 0.000 0.000 0.000 0.949 SW 0.019 1.031 0.515 0.000 0.000 0.000 0.000 0.000 0.000 1.565 WSW 0.032 1.406 1.218 0.000 0.000 0.000 0.000 0.000 0.000 2.656 W

0.018 0.703 0.797 0.000 0.000 0.000 0.000 0.000 0.000 1.518 WNW 0.006 0.328 0.187 0.047 0.000 0.000 0.000 0.000 0.000 0.569 NW 0.010 0.515 0.281 0.000 0.000 0.000 0.000 0.000 0.000 0.806 NNW 0.002 0.187 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.190 SUBTOTAL 0.141 7.216 4.358 0.094 0.000 0.000 0.000 0.000 0.000 11.809 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2135 TOTAL HOURS OF STABILITY CLASS 0 252 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G 252 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2134 TOTAL HOURS CALM 3

METEOROLOGICAL FACILITY:

Watts Bar Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 9.51 AND 45.63 METERS WIND SPEED AND DIRECTION MEASURED AT 9.72 METER LEVEL DATE PRINTED: 2004/05/10 MEAN WIND SPEED a 1.38 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS El-33

2004 WATTS BAR NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<--1.9 C/100 M)

Watts Bar Nuclear Plant APR 1, 2004 - JUN 30, 2004 WIND SPEED(MPH)

CALM 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 WIND DIRECTION

>=24.5 TOTAL N

0.000 NNE 0.000 NE 0.000 ENE 0.000 E

0.000 ESE 0.000 SE 0.000 SSE 0.000 5

0.000 SSW 0.000 SW 0.000 WSW 0.000 W

0.000 Wr.1l 0.000 NW 0.000 N"rW 0.000 0.000 0.047 0.094 0.000 0.188 0.000 0.000 0.000 0.000 0.094 0.235 0.235 0.000 0.000 0.000 0.047 0.047 0.047 0.047 0.000 0.000 0.000 0.000 0.094 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.094 0.047 0.000 0.000 0.000 0.000 0.000 0.235 0.469 0.281 0.000 0.000 0.000 0.000 0.704 1.032 1.032 0.000 0.000 0.000 0.000 0.281 0.188 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.094 0.047 0.141 0.000 0.000 0.000 0.000 0.047 0.047 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.094 0.188 0.000 0.000 0.000 0.000 0.047 0.047 0.469 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.328 0.563 0.188 0.094 0.047 0.000 0.000 0.141 0.985 2.767 0.469 0.000 0.281 0.141 0.281 0.563 SUBTOTAL 0.000 0.000 0.235 1.829 2.298 2.486 0.000 0.000 0.000 6.848 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS A TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS TOTAL HOURS CALM METEOROLOGICAL FACILITY:

Watts Bar Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 9.51 AND 45.63 METERS WIND SPEED AND DIRECTION MEASURED AT 9.72 METER LEVEL MEAN WIND SPEED -

6.92 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS 2133 147 146 2132 0

DATE PRINTED: 2004/08/26 El-34

2004 WATTS BAR NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<c-1.7 C/100 M)

Watts Bar Nuclear Plant APR 1, 2004 - JUN 30, 2004 WIND WIND SPEED(MPH)

DIRECTION CALM 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

0.000 0.000 0.000 0.281 0.000 0.235 0.000 0.000 0.000 0.516 NNE 0.000 0.000 0.000 0.094 0.188 0.094 0.000 0.000 0.000 0.375 NE 0.000 0.000 0.047 0.047 0.141 0.000 0.000 0.000 0.000 0.235 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E

0.000 0.000 0.000 0.094 0.000 0.000 0.000 0.000 0.000 0.094 ESE 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.047 SE 0.000 0.000 0.047 0.000 0.047 0.000 0.000 0.000 0.000 0.094 SSE 0.000 0.000 0.141 0.047 0.094 0.000 0.000 0.000 0.000 0.281 S

0.000 0.000 0.235 0.328 0.469 0.281 0.000 0.000 0.000 1.313 SS 0.000 0.000 0.047 0.704 0.375 0.281 0.000 0.000 0.000 1.407 SW 0.000 0.000 0.047 0.141 0.047 0.000 0.000 0.000 0.000 0.235 WSW 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.047 W

0.000 0.000 0.047 0.000 0.047 0.000 0.000 0.000 0.000 0.094 War 0.000 0.000 0.047 0.047 0.047 0.141 0.047 0.000 0.000 0.328

  • w 0.000 0.000 0.047 0.047 0.047 0.000 0.000 0.000 0.000 0.141 NN4 0.000 0.000 0.047 0.094 0.094 0.094 0.000 0.000 0.000 0.328 SUBTOTAL 0.000 0.000 0.750 1.970 1.642 1.126 0.047 0.000 0.000 5.535 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2133 TOTAL HOURS OF STABILITY CLASS B 118 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B 118 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2132 TOTAL HOURS CALM 0

METEOROLOGICAL FACILITY:

Watts Bar Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 9.51 AND 45.63 METERS WIND SPEED AND DIRECTION MEASURED AT 9.72 METER LEVEL DATE PRINTED: 2004/08/26 MEAN WIND SPEED

  • 5.85 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS EI-35

2004 WATTS BAR NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<.-1.5 C/100 M)

Watts Bar Nuclear Plant APR 1,

2004 - JUN 30, 2004 WIND WIND SPEED (MPH)

DIRECTION CALM 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>s24.5 TOTAL N

0.000 0.000 0.047 0.094 0.141 0.047 0.000 0.000 0.000 0.328 NNE 0.000 0.000 0.047 0.235 0.094 0.000 0.000 0.000 0.000 0.375 NE 0.000 0.000 0.094 0.047 0.047 0.000 0.000 0.000 0.000 0.188 ENE 0.000 0.000 0.141 0.047 0.000 0.000 0.000 0.000 0.000 0.188 E

0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.047 ESE 0.000 0.000 0.094 0.000 0.000 0.000 0.000 0.000 0.000 0.094 SE 0.000 0.000 0.047 0.141 0.000 0.000 0.000 0.000 0.000 0.188 SSE 0.000 0.000 0.047 0.047 0.000 0.000 0.000 0.000 0.000 0.094 S

0.000 0.000 0.047 0.563 0.141 0.047 0.000 0.000 0.000 0.797 SSW 0.000 0.000 0.141 0.563 0.563 0.469 0.000 0.000 0.000 1.735 SW 0.000 0.000 0.094 0.235 0.094 0.000 0.000 0.000 0.000 0.422 WSW 0.000 0.000 0.047 0.047 0.047 0.000 0.000 0.000 0.000 0.141 W

0.000 0.000 0.141 0.000 0.000 0.000 0.000 0.000 0.000 0.141 WN, 0.000 0.000 0.047 0.094 0.047 0.141 0.000 0.000 0.000 0.328 NW 0.000 0.000 0.094 0.000 0.094 0.188 0.000 0.000 0.000 0.375 NN4 0.000 0.000 0.047 0.094 0.141 0.188 0.000 0.000 0.000 0.469 SUBTOTAL 0.000 0.000 1.173 2.251 1.407 1.079 0.000 0.000 0.000 5.910 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2133 TOTAL HOURS OF STABILITY CLASS C 126 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C 126 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2132 TOTAL HOURS CALM 0

METEOROLOGICAL FACILITY:

Watts Bar Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 9.51 AND 45.63 METERS WIND SPEED AND DIRECTION MEASURED AT 9.72 METER LEVEL DATE PRINTED: 2004/08/26 MEAN WIND SPEED

  • 5.51 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS El-36

2004 WATTS BAR NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<--0.5 C/100 M)

Watts Bar Nuclear Plant APR 1, 2004 - JUN 30, 2004 WIND WIND SPEED(MPH)

DIRECTION CALM 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>,24.5 TOTAL N

0.000 0.000 0.375 0.610 0.844 0.375 0.000 0.000 0.000 2.205 NNE 0.000 0.000 0.516 0.610 0.891 0.235 0.000 0.000 0.000 2.251 NE 0.000 0.000 0.281 0.422 0.18B 0.000 0.000 0.000 0.000 0.891 ENE 0.000 0.047 0.422 0.141 0.047 0.000 0.000 0.000 0.000 0.657 E

0.000 0.000 0.328 0.000 0.000 0.000 0.000 0.000 0.000 0.328 ESE 0.000 0.000 0.188 0.000 0.000 0.000 0.000 0.000 0.000 0.188 SE 0.000 0.141 0.610 0.000 0.047 0.000 0.000 0.000 0.000 0.797 SSE 0.000 0.094 0.844 0.188 0.141 0.000 0.000 0.000 0.000 1.266 S

0.000 0.235 1.642 1.220 0.422 0.469 0.000 0.000 0.000 3.987 SSW 0.000 0.188 2.767 3.002 1.970 1.313 0.047 0.000 0.000 9.287 SW 0.000 0.094 1.266 1.220 0.141 0.047 0.000 0.000 0.000 2.767 WSW 0.000 0.094 0.704 0.281 0.094 0.000 0.000 0.000 0.000 1.173 W

0.000 0.188 0.235 0.375 0.235 0.000 0.000 0.000 0.000 1.032 WN1W' 0.000 0.047 0.281 0.375 0.328 0.235 0.000 0.000 0.000 1.266 NW 0.000 0.047 0.188 0.328 0.188 0.469 0.000 0.000 0.000 1.220 Ntlf 0.000 0.000 0.281 0.657 0.750 0.657 0.000 0.000 0.000 2.345 SUBTOTAL 0.000 1.173 10.929 9.428 6.285 3.799 0.047 0.000 0.000 31.660 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2133 TOTAL HOURS OF STABILITY CLASS D 675 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D 675 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2132 TOTAL HOURS CALM 0

METEOROLOGICAL FACILITY:

Watts Bar Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 9.51 AND 45.63 METERS WIND SPEED AND DIRECTION MEASURED AT 9.72 METER LEVEL DATE PRINTED: 2004/08/26 MEAN WIND SPEED =

4.56 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS El-37

2004 WATTS BAR NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

Watts Bar Nuclear Plant APR 1, 2004 - JUN 30, 2004 WIND WIND SPEED(MPH)

DIRECTION CALM 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

0.000 0.094 0.375 0.375 0.047 0.000 0.000 0.000 0.000 0.891 NNE 0.000 0.094 0.188 0.281 0.000 0.000 0.000 0.000 0.000 0.563 NE 0.000 0.000 0.375 0.141 0.000 0.000 0.000 0.000 0.000 0.516 ENE 0.000 0.000 0.328 0.235 0.000 0.000 0.000 0.000 0.000 0.563 E

0.000 0.094 0.141 0.000 0.000 0.000 0.000 0.000 0.000 0.235 ESE 0.000 0.235 0.047 0.047 0.000 0.000 0.000 0.000 0.000 0.328 SE 0.000 0.375 0.141 0.000 0.047 0.000 0.000 0.000 0.000 0.563 SSE 0.000 0.328 0.422 0.094 0.000 0.000 0.000 0.000 0.000 0.844 S

0.000 0.657 1.360 0.657 0.281 0.094 0.000 0.000 0.000 3.049 SSW 0.000 0.704 2.627 1.548 0.516 0.188 0.000 0.000 0.000 5.582 SW 0.000 0.844 1.454 0.235 0.047 0.000 0.000 0.000 0.000 2.580 WSW 0.000 0.891 0.938 0.047 0.094 0.000 0.000 0.000 0.000 1.970 W

0.000 0.797 0.844 0.188 0.047 0.000 0.000 0.000 0.000 1.876 WNW 0.000 0.516 0.704 0.281 0.188 0.000 0.000 0.000 0.000 1.689 NW 0.000 0.375 0.469 0.188 0.047 0.000 0.000 0.000 0.000 1.079 NNW 0.000 0.328 0.235 0.328 0.469 0.281 0.094 0.000 0.000 1.735 SUBTOTAL 0.000 6.332 10.647 4.644 1.782 0.563 0.094 0.000 0.000 24.062 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2133 TOTAL HOURS OF STABILITY CLASS E 513 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E 513 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2132 TOTAL HOURS CALM 0

METEOROLOGICAL FACILITY:

Watts Bar Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 9.51 AND 45.63 METERS WIND SPEED AND DIRECTION MEASURED AT 9.72 METER LEVEL DATE PRINTED: 2004/08/26 MEAN WIND SPEED =

2.83 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS EI-38

2004 WATTS BAR NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

Watts Bar Nuclear Plant APR 1. 2004 -

JUN 30, 2004 WIND WIND SPEED(MPH)

DIRECTION CALM 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

0.001 0.094 0.188 0.000 0.000 0.000 0.000 0.000 0.000 0.282 NNE 0.001 0.141 0.235 0.047 0.000 0.000 0.000 0.000 0.000 0.423 NE 0.001 0.094 0.094 0.000 0.000 0.000 0.000 0.000 0.000 0.188 ENE 0.001 0.047 0.235 0.000 0.000 0.000 0.000 0.000 0.000 0.282 E

0.001 0.094 0.141 0.000 0.000 0.000 0.000 0.000 0.000 0.235 ESE 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.047 SE 0.001 0.281 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.282 SSE 0.001 0.375 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.376 S

0.003 0.563 0.422 0.047 0.000 0.000 0.000 0.000 0.000 1.035 SSW 0.006 0.891 0.844 0.375 0.000 0.000 0.000 0.000 0.000 2.116 SW 0.007 1.220 0.985 0.000 0.000 0.000 0.000 0.000 0.000 2.212 WSW 0.007 1.313 0.891 0.047 0.000 0.000 0.000 0.000 0.000 2.259 W

0.007 1.266 0.891 0.000 0.000 0.000 0.000 0.000 0.000 2.165 WNW 0.006 1.173 0.704 0.000 0.000 0.000 0.000 0.000 0.000 1.882 NW 0.002 0.469 0.188 0.094 0.047 0.000 0.000 0.000 0.000 0.800 NIN 0.002 0.141 0.422 0.094 0.000 0.000 0.000 0.000 0.000 0.658 SUBTOTAL 0.047 8.161 6.285 0.704 0.047 0.000 0.000 0.000 0.000 15.244 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2133 TOTAL HOURS OF STABILITY CLASS F 325 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F 325 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2132 TOTAL HOURS CALM 1-METEOROLOGICAL FACILITY:

Watts Bar Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 9.51 AND 45.63 METERS WIND SPEED AND DIRECTION MEASURED AT 9.72 METER LEVEL DATE PRINTED: 2004/08/26 MEAN WIND SPEED =

1.63 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS El-39

2004 WATTS BAR NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

Watts Bar Nuclear Plant APR 1, 2004 - JUN 30, 2004 WIND WIND SPEED(MPH)

DIRECTION CALM 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>'24.5 TOTAL N

0.002 0.188 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.189 NNE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NE 0.001 0.047 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.095 ENE 0.001 0.047 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.095 E

0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SE 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 SSE 0.002 0.235 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.237 S

0.005 0.469 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.520 SSW 0.007 0.797 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.804 SW 0.015 1.313 0.422 0.000 0.000 0.000 0.000 0.000 0.000 1.751 WSW 0.022 2.017 0.516 0.000 0.000 0.000 0.000 0.000 0.000 2.555 W

0.022 1.923 0.563 0.000 0.000 0.000 0.000 0.000 0.000 2.508 WNA'l 0.011 0.844 0.422 0.000 0.000 0.000 0.000 0.000 0.000 1.278 NW 0.003 0.188 0.141 0.000 0.000 0.000 0.000 0.000 0.000 0.331 NN1d 0.002 0.188 0.094 0.000 0.000 0.000 0.000 0.000 0.000 0.284 SUBTOTAL 0.094 8.349 2.298 0.000 0.000 0.000 0.000 0.000 0.000 10.741 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2133 TOTAL HOURS OF STABILITY CLASS G 229 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G 229 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2132 TOTAL HOURS CALM 2

METEOROLOGICAL FACILITY:

Watts Bar Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 9.51 AND 45.63 METERS WIND SPEED AND DIRECTION MEASURED AT 9.72 METER LEVEL DATE PRINTED: 2004/08/26 MEAN WIND SPEED =

1.19 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS El-40

2004 WATTS BAR NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINr PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<(-l.9 C/100 M)

Watts Bar Nuclear Plant JUL 1. 2004 -

SEP 30, 2004 WIND WIND SPEED(MPH)

DIRECTION CALM 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>X24.5 TOTAL N

0.000 0.000 0.047 0.000 0.047 0.000 0.000 0.000 0.000 0.094 NNE 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.047 NE 0.000 0.000 0.000 0.094 0.000 0.000 0.000 0.000 0.000 0.094 ENE 0.000 0.000 0.047 0.047 0.000 0.000 0.000 0.000 0.000 0.094 E

0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SSE 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.047 S

0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SSW 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.047 SW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WSW 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.047 W

0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NNW 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.047 SUBTOTAL 0.000 0.000 0.234 0.140 0.140 0.000 0.000 0.000 0.000 0.514 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2140 TOTAL HOURS OF STABILITY CLASS A 11 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A 11 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2138 TOTAL HOURS CALM 0

METEOROLOGICAL FACILITY:

Watts Bar Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 9.51 AND 45.63 METERS WIND SPEED AND DIRECTION MEASURED AT 9.72 METER LEVEL DATE PRINTED: 2004/12/06 MEAN WIND SPEED =

4.17 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS EI-41

2004 WATTS BAR NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<--1.7 C/100 M)

Watts Bar Nuclear Plant JUL 1, 2004 -

SEP 30, 2004 WIND WIND SPEED(MPH)

DIRECTION CALM 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

0.000 0.000 0.000 0.047 0.047 0.094 0.000 0.000 0.000 0.187 NNE 0.000 0.000 0.000 0.000 0.140 0.655 0.000 0.000 0.000 0.795 NE 0.000 0.000 0.000 0.047 0.000 0.140 0.000 0.000 0.000 0.187 ENE 0.000 0.000 0.000 0.000 0.187 0.047 0.000 0.000 0.000 0.234 E

0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.047 SE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SSE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 S

0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.047 SSW 0.000 0.000 0.047 0.000 0.234 0.047 0.000 0.000 0.000 0.327 SW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WSW 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.047 W

0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WHW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NW 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.047 NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SUBTOTAL 0.000 0.000 0.140 0.094 0.702 0.982 0.000 0.000 0.000 1.918 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2140 TOTAL HOURS OF STABILITY CLASS B 41 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B 41 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2138 TOTAL HOURS CALM 0

METEOROLOGICAL FACILITY:

Watts Bar Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 9.51 AND 45.63 METERS WIND SPEED AND DIRECTION MEASURED AT 9.72 METER LEVEL DATE PRINTED: 2004/12/06 MEAN WIND SPEED =

7.49 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS El-42

-I 2004 WATTS BAR NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

Watts Bar Nuclear Plant JUL 1, 2004 -

SEP 30, 2004 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NI'm SUB3TOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.6-1.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.5-3.4 0.000 0.094 0.094 0.140 0.094 0.000 0.047 0.000 0.000 0.047 0.000 0.000 0.000 0.047 0.000 0.000 0.561 WIND SPEED(MPH) 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 0.140 0.094 0.327 0.000 0.000 0.187 0.327 0.421 0.000 0.000 0.094 0.000 0.000 0.000 0.000 0.281 0.047 0.000 0.000 0.000 0.047 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.327 0.374 0.047 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.140 0.000 0.000 0.000 0.000 0.187 0.140 0.140 0.000 0.000 1.590 1.029 1.029 0.000 0.000

>-24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.561 1.029 0.187 0.468 0.187 0.000 0.047 0.047 0.047 0.795 0.047 0.047 0.047 0.094 0.140 0.468 4.210 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS C TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS TOTAL HOURS CALM 2140 91 90 2138 0

METEOROLOGICAL FACILITY:

Watts Bar Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 9.51 AND 45.63 METERS WIND SPEED AND DIRECTION MEASURED AT 9.72 METER LEVEL MEAN WIND SPEED

  • 5.79 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2004/12/06 El-43

2004 WATTS BAR NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

Watts Bar Nuclear Plant JUL 1, 2004 -

SEP 30, 2004 WIND WIND SPEED(MPH)

DIRECTION CALM 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

0.000 0.047 0.608 1.918 1.543 0.842 0.047 0.000 0.000 5.005 NNE 0.000 0.047 0.608 1.216 1.403 1.263 0.047 0.000 0.000 4.584 NE 0.000 0.047 0.514 0.795 0.421 0.187 0.047 0.000 0.000 2.011 E1E 0.000 0.000 0.889 0.702 0.094 0.047 0.047 0.000 0.000 1.777 E

0.000 0.000 1.029 0.281 0.047 0.094 0.000 0.000 0.000 1.450 ESE 0.000 0.000 0.561 0.094 0.000 0.000 0.000 0.000 0.000 0.655 SE 0.000 0.000 0.702 0.187 0.000 0.000 0.000 0.000 0.000 0.889 SSE 0.000 0.047 0.702 0.327 0.000 0.000 0.000 0.000 0.000 1.076 S

0.000 0.140 1.029 1.216 0.234 0.000 0.000 0.000 0.000 2.619 SSW 0.000 0.140 1.777 3.789 1.029 0.000 0.000 0.000 0.000 6.735 SW 0.000 0.187 1.123 1.216 0.187 0.000 0.000 0.000 0.000 2.713 WSW 0.000 0.094 0.561 0.234 0.000 0.000 0.000 0.000 0.000 0.889 W

0.000 0.047 0.421 0.187 0.000 0.000 0.000 0.000 0.000 0.655 WNW 0.000 0.047 0.374 0.421 0.047 0.094 0.000 0.000 0.000 0.982 NW 0.000 0.047 0.234 0.094 0.327 0.281 0.000 0.000 0.000 0.982 NNW 0.000 0.000 0.281 0.702 1.310 1.029 0.140 0.000 0.000 3.461 SUBTOTAL 0.000 0.889 11.413 13.377 6.642 3.835 0.327 0.000 0.000 36.483 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2140 TOTAL HOURS OF STABILITY CLASS D 781 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D 780 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2138 TOTAL HOURS CALM 0

METEOROLOGICAL FACILITY:

Watts Bar Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 9.51 AND 45.63 METERS WIND SPEED AND DIRECTION MEASURED AT 9.72 METER LEVEL DATE PRINTED: 2004/12/06 MEAN WIND SPEED -

4.67 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS El-44

2004 WATTS BAR NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/l00 M)

Watts Bar Nuclear Plant JUL 1, 2004 -

SEP 30, 2004 WIND WIND SPEED(MPH)

DIRECTION CALM 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

0.001 0.047 0.561 0.842 0.935 0.281 0.047 0.000 0.000 2.714 NME 0.001 0.187 0.421 0.514 0.748 0.374 0.187 0.000 0.000 2.434 NE 0.002 0.047 0.702 0.421 0.094 0.000 0.140 0.000 0.000 1.405 ENE 0.003 0.281 0.842 0.281 0.000 0.047 0.000 0.000 0.000 1.453 E

0.002 0.234 0.795 0.047 0.047 0.000 0.000 0.000 0.000 1.125 ESE 0.001 0.234 0.047 0.000 0.047 0.000 0.000 0.000 0.000 0.328 SE 0.001 0.094 0.187 0.327 0.000 0.000 0.000 0.000 0.000 0.609 SSE 0.001 0.281 0.187 0.094 0.000 0.000 0.000 0.000 0.000 0.562 S

0.005 0.421 1.497 0.421 0.000 0.000 0.000 0.000 0.000 2.343 SSW 0.007 0.748 2.011 0.935 0.514 0.047 0.000 0.000 0.000 4.263 SW 0.007 0.982 1.777 0.327 0.000 0.000 0.000 0.000 0.000 3.094 WSW 0.004 0.935 0.889 0.047 0.094 0.000 0.000 0.000 0.000 1.969 W

0.003 0.795 0.561 0.234 0.047 0.000 0.000 0.000 0.000 1.640 WNW 0.004 0.842 0.702 0.094 0.000 0.047 0.000 0.000 0.000 1.688 NW 0.002 0.421 0.561 0.234 0.000 0.000 0.000 0.000 0.000 1.218 NNW 0.003 0.327 0.935 1.076 0.889 0.140 0.000 0.000 0.000 3.371 SUBTOTAL 0.047 6.876 12.675 5.893 3.414 0.935 0.374 0.000 0.000 30.215 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2140 TOTAL HOURS OF STABILITY CLASS E 646 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E 646 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2138 TOTAL HOURS CALM 1

METEOROLOGICAL FACILITY:

Watts Bar Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 9.51 AID 45.63 METERS WIND SPEED AND DIRECTION MEASURED AT 9.72 METER LEVEL DATE PRINTED: 2004/12/06 MEAN WIND SPEED -

3.23 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E1-45

2004 WATTS BAR NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<- 4.0 C/100 M)

Watts Bar Nuclear Plant JUL 1, 2004 -

SEP 30, 2004 WIND SPEED(MPH)

CALM 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL 0.000 0.187 0.187 0.094 0.000 0.000 0.000 0.000 0.000 0.468 0.000 0.187 0.281 0.000 0.000 0.000 0.000 0.000 0.000 0.468 0.000 0.281 0.281 0.000 0.000 0.000 0.000 0.000 0.000 0.561 0.000 0.421 0.327 0.094 0.000 0.000 0.000 0.000 0.000 0.842 0.000 0.421 0.187 0.000 0.000 0.000 0.000 0.000 0.000 0.608 0.000 0.140 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.140 0.000 0.094 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.140 0.000 0.140 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.140 0.000 0.281 0.094 0.000 0.000 0.000 0.000 0.000 0.000 0.374 0.000 0.468 0.795 0.047 0.000 0.000 0.000 0.000 0.000 1.310 0.000 0.795 0.982 0.000 0.000 0.000 0.000 0.000 0.000 1.777 0.000 1.964 1.123 0.000 0.000 0.000 0.000 0.000 0.000 3.087 0.000 2.713 0.748 0.047 0.000 0.000 0.000 0.000 0.000 3.508 0.000 2.152 0.889 0.047 0.000 0.000 0.000 0.000 0.000 3.087 0.000 1.871 1.123 0.094 0.000 0.000 0.000 0.000 0.000 3.087 0.000 0.140 0.561 0.047 0.000 0.047 0.000 0.000 0.000 0.795 0.000 12.254 7.624 0.468 0.000 0.047 0.000 0.000 0.000 20.393 WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW W0S4 W

W4W NW OAW SUBTOTAL TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS F TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS TOTAL HOURS CALM 2140 436 436 2138 0

METEOROLOGICAL FACILITY:

Watts Bar Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 9.51 AND 45.63 METERS WIND SPEED AND DIRECTION MEASURED AT 9.72 METER LEVEL MEAN WIND SPEED =

1.52 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2004/12/06 El-46

2004 WATTS BAR NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

Watts Bar Nuclear Plant JUL 1, 2004 -

SEP 30, 2004 WIND WIND SPEED(MPH)

DIRECTION CALM 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

0.000 0.140 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.187 NNE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NE 0.000 0.094 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.094 ENE 0.000 0.000 0.094 0.000 0.000 0.000 0.000 0.000 0.000 0.094 E

0.000 0.094 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.094 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SSE 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 S

0.000 0.187 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.187 SSW 0.000 0.094 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.094 SW 0.000 0.421 0.187 0.000 0.000 0.000 0.000 0.000 0.000 0.608 WSW 0.000 0.795 0.234 0.000 0.000 0.000 0.000 0.000 0.000 1.029 W

0.000 0.982 0.281 0.000 0.000 0.000 0.000 0.000 0.000 1.263 W~el 0.000 0.702 0.281 0.000 0.000 0.000 0.000 0.000 0.000 0.982 NW 0.000 0.702 0.468 0.000 0.000 0.000 0.000 0.000 0.000 1.169 N1d 0.000 0.374 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.421 SUBTOTAL 0.000 4.630 1.637 0.000 0.000 0.000 0.000 0.000 0.000 6.268 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2140 TOTAL HOURS OF STABILITY CLASS G 134 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS a 134 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2138 TOTAL HOURS CALM 0

METEOROLOGICAL FACILITY:

Watts Bar Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 9.51 AND 45.63 METERS WIND SPEED AND DIRECTION MEASURED AT 9.72 METER LEVEL DATE PRINTED: 2004/12/06 MEAN WIND SPEED =

1.24 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS El-47

2004 WATTS BAR NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

Watts Bar Nuclear Plant OCT 1, 2004 -

DEC 31, 2004 WIND WIND SPEED(MPH)

DIRECTION CALM 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.046 NNE 0.000 0.000 0.046 0.000 0.000 0.091 0.000 0.000 0.000 0.137 NE 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.046 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E

0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.046 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SE 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.046 SSE 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.046 S

0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.046 SSW 0.000 0.000 0.000 0.046 0.046 0.046 0.000 0.000 0.000 0.137 SW 0.000 0.000 0.000 0.091 0.091 0.000 0.000 0.000 0.000 0.182 WSW 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.046 W

0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 "d

0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SUBTOTAL 0.000 0.000 0.182 0.182 0.137 0.274 0.000 0.000 0.000 0.776 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2193 TOTAL HOURS OF STABILITY CLASS A 17 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A 17 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2192 TOTAL HOURS CALM 0

METEOROLOGICAL FACILITY:

Watts Bar Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 9.51 AND 45.63 METERS WIND SPEED AND DIRECTION MEASURED AT 9.72 METER LEVEL DATE PRINTED: 2005/01/28 MEAN WIND SPEED

  • 5.82 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS El-48

2004 WATTS BAR NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<--1.7 C/100 M)

Watts Bar Nuclear Plant OCT 1, 2004 - DEC 31, 2004 WIND WIND SPEED(MPH)

DIRECTION CALM 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.046 NNE 0.000 0.000 0.000 0.274 0.046 0.182 0.000 0.000 0.000 0.502 NE 0.000 0.000 0.000 0.046 0.046 0.046 0.000 0.000 0.000 0.137 ENE 0.000 0.000 0.000 0.091 0.000 0.000 0.000 0.000 0.000 0.091 E

0.000 0.000 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.091 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SSE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 S

0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SSW 0.000 0.000 0.046 0.091 0.182 0.046 0.000 0.000 0.000 0.365 SW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WSW 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.046 W

0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.046 wfw 0.000 0.000 0.000 0.000 0.000 0.137 0.000 0.000 0.000 0.137 NW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NNW 0.000 0.000 0.000 0.000 0.046 0.046 0.046 0.000 0.000 0.137 SUBTOTAL 0.000 0.000 0.091 0.547 0.365 0.547 0.046 0.000 0.000 1.597 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2193 TOTAL HOURS OF STABILITY CLASS B 36 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B 35 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2192 TOTAL HOURS CALM

.0 METEOROLOGICAL FACILITY:

Watts Bar Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 9.51 AND 45.63 METERS WIND SPEED AND DIRECTION MEASURED AT 9.72 METER LEVEL DATE PRINTED: 2005/01/28 MEAN WIND SPEED =

6.77 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS El-49

2004 WATTS BAR NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

Watts Bar Nuclear Plant OCT 1, 2004 - DEC 31, 2004 WIND WIND SPEED(MPH)

DIRECTION CALM 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>.24.5 TOTAL N

0.000 0.000 0.046 0.000 0.137 0.137 0.000 0.000 0.000 0.319 NNE 0.000 0.000 0.046 0.274 0.091 0.182 0.000 0.000 0.000 0.593 NE 0.000 0.000 0.091 0.091 0.000 0.000 0.000 0.000 0.000 0.182 ENE 0.000 0.000 0.137 0.137 0.046 0.000 0.000 0.000 0.000 0.319 E

0.000 0.000 0.137 0.000 0.000 0.000 0.000 0.000 0.000 0.137 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SSE 0.000 0.000 0.000 0.091 0.000 0.000 0.000 0.000 0.000 0.091 S

0.000 0.000 0.000 0.046 0.091 0.137 0.000 0.000 0.000 0.274 SSW 0.000 0.000 0.000 0.046 0.182 0.228 0.046 0.000 0.000 0.502 SW 0.000 0.000 0.000 0.000 0.228 0.000 0.000 0.000 0.000 0.228 WSW 0.000 0.000 0.000 0.000 0.091 0.000 0.000 0.000 0.000 0.091 W

0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WNW 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.046 NW 0.000 0.000 0.000 0.000 0.091 0.046 0.046 0.000 0.000 0.182 Ads'l 0.000 0.000 0.000 0.000 0.046 0.137 0.000 0.000 0.000 0.182 SUBTOTAL 0.000 0.000 0.456 0.684 1.004 0.912 0.091 0.000 0.000 3.148 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2193 TOTAL HOURS OF STABILITY CLASS C 69 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C 69 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2192 TOTAL HOURS CALM 0

METEOROLOGICAL FACILITY:

Wbtts Bar Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 9.51 AND 45.63 METERS WIND SPEED AND DIRECTION MEASURED AT 9.72 METER LEVEL DATE PRINTED: 2005/01/28 MEAN WIND SPEED -

6.45 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS El-50

2004 WATTS BAR NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUEICIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<.-0.5 C/100 M)

Watts Bar Nuclear Plant OCT 1,

2004 -

DEC 31, 2004 WIND WIND SPEED(MPH)

DIRECTION CALM 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>.24.5 TOTAL N

0.000 0.046 0.730 0.730 0.411 2.418 0.000 0.000 0.000 4.334 NNE 0.000 0.000 0.730 0.684 0.365 0.502 0.137 0.000 0.000 2.418 NE 0.000 0.228 0.912 0.639 0.319 0.182 0.000 0.000 0.000 2.281 ENE 0.000 0.091 0.593 0.091 0.091 0.000 0.000 0.000 0.000 0.867 E

0.000 0.137 0.456 0.091 0.000 0.000 0.000 0.000 0.000 0.684 ESE 0.000 0.137 0.365 0.046 0.000 0.000 0.000 0.000 0.000 0.547 SE 0.000 0.046 0.274 0.000 0.000 0.000 0.000 0.000 0.000 0.319 SSE 0.000 0.137 0.639 0.182 0.000 0.000 0.000 0.000 0.000 0.958 S

0.000 0.091 1.597 1.551 0.776 0.411 0.000 0.000 0.000 4.425 SSW 0.000 0.137 1.779 2.737 1.186 1.323 0.137 0.000 0.000 7.299 SW 0.000 0.046 1.277 1.505 0.365 0.091 0.000 0.000 0.000 3.285 WSW 0.000 0.091 0.821 0.502 0.274 0.182 0.000 0.000 0.000 1.870 W

0.000 0.365 0.411 0.228 0.411 0.228 0.000 0.000 0.000 1.642 WNW 0.000 0.228 0.274 0.274 0.776 0.365 0.000 0.000 0.000 1.916 NW 0.000 0.000 0.593 0.182 0.456 0.456 0.091 0.000 0.000 1.779 NNW 0.000 0.000 0.639 0.456 0.411 1.277 0.091 0.000 0.000 2.874 SUBTOTAL 0.000 1.779 12.089 9.900 5.839 7.436 0.456 0.000 0.000 37.500 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2193 TOTAL HOURS OF STABILITY CLASS D 822 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D 822 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2192 TOTAL HOURS CALM 0

METEOROLOGICAL FACILITY:

Watts Bar Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 9.51 AND 45.63 METERS WIND SPEED AND DIRECTION MEASURED AT 9.72 METER LEVEL DATE PRINTED: 2005/01/28 MEAN WIND SPEED = 5.02 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS El-51

2004 WATTS BAR NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SES SW WSW W

WM4 NW NNW SUBTOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.6-1.4 0.091 0.319 0.182 0.182 0.319 0.182 0.228 0.228 0.319 0.684 0.547 0.730 1.049 0.684 0.456 0.274 6.478 STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

Watts Bar Nuclear Plant OCT 1, 2004 - DEC 31, 2004 WIND SPEED(MPH) 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 1.049 0.228 0.319 0.456 0.000 0.000 0.365 0.228 0.137 0.000 0.000 0.000 1.186 0.456 0.091 0.000 0.000 0.000 1.049 0.228 0.000 0.000 0.000 0.000 0.456 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.365 0.000 0.000 0.000 0.000 0.000 0.137 0.000 0.000 0.046 0.000 0.000 1.049 0.365 0.502 0.274 0.000 0.000 2.281 2.007 0.821 0.912 0.046 0.000 1.642 0.593 0.091 0.000 0.000 0.000 0.912 0.456 0.091 0.091 0.000 0.000 1.004 0.274 0.137 0.091 0.000 0.000 0.912 0.182 0.046 0.091 0.000 0.000 0.821 0.319 0.137 0.137 0.000 0.000 1.004 0.046 0.137 0.046 0.000 0.000 14.279 5.383 2.509 2.144 0.046 0.000

>-24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 2.144 1.049 1.916 1.4 60 0.776 0.228 0.593 0.411 2.509 6.752 2.874 2.281 2.555 1.916 1.870 1.505 30.839 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS E TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS TOTAL HOURS CALM 2193 676 676 2192 0

METEOROLOGICAL FACILITY:

Watts Bar Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 9.51 AND 45.63 METERS WIND SPEED AND DIRECTION MEASURED AT 9.72 METER LEVEL MEAN WIND SPEED. 3.21 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2005/01/28 El-52

2004 WATTS BAR NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

Watts Bar Nuclear Plant OCT 1, 2004 -

DEC 31, 2004 WIND WIND SPEED(MPH)

DIRECTION CALM 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>.24.5 TOTAL N

0.004 0.456 0.274 0.000 0.000 0.000 0.000 0.000 0.000 0.734 NNE 0.002 0.182 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.275 NE 0.003 0.228 0.182 0.000 0.000 0.000 0.000 0.000 0.000 0.413 ENE 0.002 0.000 0.274 0.091 0.000 0.000 0.000 0.000 0.000 0.367 E

0.001 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.092 ESE 0.001 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.092 SE 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 SSE 0.001 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.092 S

0.003 0.137 0.411 0.046 0.000 0.000 0.000 0.000 0.000 0.596 SSW 0.005 0.228 0.547 0.137 0.000 0.000 0.000 0.000 0.000 0.917 SW 0.009 0.547 0.912 0.091 0.000 0.000 0.000 0.000 0.000 1.560 WSW 0.012 1.049 0.867 0.000 0.000 0.000 0.000 0.000 0.000 1.928 W

0.022 2.372 1.186 0.000 0.000 0.000 0.000 0.000 0.000 3.580 WNW 0.016 1.642 1.049 0.091 0.000 0.000 0.000 0.000 0.000 2.799 NW 0.009 0.684 0.776 0.000 0.000 0.000 0.000 0.000 0.000 1.469 NNW 0.003 0.228 0.274 0.000 0.000 0.000 0.000 0.000 0.000 0.505 SUBTOTAL 0.091 8.029 6.889 0.456 0.000 0.000 0.000 0.000 0.000 15.465 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2193 TOTAL HOURS OF STABILITY CLASS F 339 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F 339 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2192 TOTAL HOURS CALM 2

METEOROLOGICAL FACILITY:

Watts Bar Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 9.51 AND 45.63 METERS WIND SPEED AND DIRECTION MEASURED AT 9.72 METER LEVEL DATE PRINTED: 2005/01/28 MEAN WIND SPEED -

1.55 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS EI-53

2004 WATTS BAR NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

Watts Bar Nuclear Plant OCT 1, 2004 -

DEC 31, 2004 WIND WIND SPEED(MPH)

DIRECTION CALM 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

0.002 0.182 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.184 NNE 0.004 0.274 0.182 0.000 0.000 0.000 0.000 0.000 0.000 0.460 NE 0.003 0.319 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.368 ENE 0.002 0.046 0.182 0.000 0.000 0.000 0.000 0.000 0.000 0.230 E

0.001 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.092 ESE 0.002 0.137 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.230 SE 0.001 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.092 SSE 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 S

0.001 0.046 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.138 SSW 0.004 0.319 0.137 0.091 0.000 0.000 0.000 0.000 0.000 0.551 SW 0.008 0.502 0.365 0.000 0.000 0.000 0.000 0.000 0.000 0.874 WSW 0.015 0.912 0.821 0.046 0.000 0.000 0.000 0.000 0.000 1.794 W

0.020 1.369 0.912 0.000 0.000 0.000 0.000 0.000 0.000 2.301 WNW 0.014 1.277 0.365 0.000 0.000 0.000 0.000 0.000 0.000 1.657 NW 0.010 0.730 0.411 0.000 0.000 0.000 0.000 0.000 0.000 1.150 NNW 0.004 0.274 0.228 0.000 0.000 0.000 0.000 0.000 0.000 0.506 SUBTOTAL 0.091 6.569 3.878 0.137 0.000 0.000 0.000 0.000 0.000 10.675 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2193 TOTAL HOURS OF STABILITY CLASS G 234 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G 234 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2192 TOTAL HOURS CALM 2

METEOROLOGICAL FACILITY:

Watts Bar Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 9.51 AND 45.63 METERS WIND SPEED AND DIRECTION MEASURED AT 9.72 METER LEVEL DATE PRINTED: 2005/01/28 MEAN WIND SPEED

  • 1.40 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS El-54

2004 WATTS BAR NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT ATTACHMENT 1.0 Deviations from ODCM Controls/Surveillance Requirements 01/23/2004 1/2.1.2 Table 1.1-2 Item 3.b Action D 03/02/2004 1/2.1.2 Table 1.1-2 Item 3.b Action D 05/22/2004 1/2.1.1 Table 1.1-2 Item 1.1-1 Items 2.a 06/01/2004 1/2.2.2 Table 2.2-2 Item K 09/03/2004 1/2.1.1 Table 1.1-1 Item 2.a The particulate and iodine compensatory sampler required during periods when the radiation monitor skid on the Unit 1 Shield Building Exhaust is inoperable was installed but no sample was obtained during a release. The cause of the missed sample was a valve located upstream of the compensatory sampler had been isolated to perform a maintenance activity. This resulted in an unmonitored release.

The particulate filter on the compensatory sampler installed on the Unit 1 Shield Building was found misaligned during the weekly changeout. This resulted in the sample not being representative.

The 12 hour1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> compensatory sample required during periods when the ERCW radiation monitors 0-RE-90-1 33 and 0-RE-90-140 are inoperable was obtained 20 minutes late. The sample was analyzed and no radioactivity was found.

During the weekly changeout of the particulate and iodine filters on the 1-RE-90-101 Auxiliary Building Exhaust monitor it was discovered that the sample flow and start time had not been recorded following the monitor being returned to service on 05128/04. Flow estimates and times were used to analyze the filters. No radioactivity was detected on the filters.

The 12 hour1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> compensatory sample required during periods when the ERCW radiation monitors 0-RE-90-133 and 0-RE-90-140 are inoperable was missed as a result of the inability to obtain flow during a maintenance activity that lasted 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and 3 minutes.

El-55

2004 WATTS BAR NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT ATTACHMENT 2.0 Radiation Monitors Inoperable for Greater than 30 days None EI-56