Maria Korsnick 1503 Lake Road Vice President Ontario, New York 14519-9364 585.771.3494 585.771.3943 Fax maria.korsnickEconstellation.com Constellation Energy R.E. Ginna Nuclear Power Plant March 7, 2005 Ms. Donna M. Skay Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission ATTN: Document Control Desk 11555 Rockville Pike Rockville, MD 20852

Subject:

90 Day Response to NRC Generic Letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation during Design Basis Accidents at Pressurized-Water Reactors R.E. Ginna Nuclear Power Plant Docket No. 50-244

Reference:

NRC Generic Letter 2004-02: Potential Impact of Debris Blockage on Emergency Recirculation during Design Basis Accidents at Pressurized-Water Reactors, dated September 13, 2004.

Dear Ms. Skay:

The purpose of this letter is to forward the R.E. Ginna Nuclear Power Plant, LLC (Ginna LLC) 90 day response to Nuclear Regulatory Commission (NRC) Generic Letter 2004-02. The Generic Letter was issued to request evaluation of the Emergency Core Cooling System (ECCS) and Containment Spray System (CSS) recirculation functions and, if appropriate, take additional actions to ensure system function. The request is based on the identified potential susceptibility of pressurized-water reactor (PWR) recirculation sump screens to debris blockage during design basis accidents.

NRC Requested Information WMithin 90 days of the date of the safety evaluation report providing the guidance for performing the requested evaluation, addressees are requested to provide information regarding their planned actions and schedule to complete the requested evalutation. The information should include thefollowing:

1.

A description of the methodology that is used or will be used to analyze the susceptibility of the ECCS and CSS recirculation fiunctions for-youir reactor to the adverse effects identified in this generic letter ofpost-accident debris blockage and operation with debris-laden fluids identified in this generic letter. Provide the completion date of the analysis that will be performed.

/ OO/4f7/

2.

A statement of whetheryou plan to perform a containment walkdowvn surveillance in support of the analysis of the susceptibility of the ECCS and CSS recirculation functions to the adverse effects of debris blockage identijfed in this generic letter. Provide justiJfcation if no containment walkdown surveillance will be performed. Ifa containment walk-down surveillance will be performed, state the planned methodology to be used and the planned completion date.

Ginna LLC Response Ginna LLC is in the process of analyzing the susceptibility of ECCS and CSS recirculation functions to the adverse effects of post-accident debris blockage and operation with debris-laden fluids identified in Generic Letter 2004-02, utilizing the intent of industry guidance document NEI 04-07, "Pressurized-Water Reactor (PWR) Sump Performance Methodology," dated May 28, 2004. The current licensing basis for R.E. Ginna, as well as plant specific features may identify exceptions and or refinements which may be taken to the guidance given in NEI 04-07.

The analysis and exceptions or refinements to the guidance given in NEI 04-07, should they be taken, will be identified and a basis for them documented in the response to item 2 of the Generic Letter requested information, scheduled for NRC submittal by September 1, 2005. That response will provide a plant specific evaluation of debris generation, the development of a computational fluid dynamics (CFD) model of containment to determine sump fluid velocity profiles, debris transport to the ECCS recirculation sump screen, the head loss associated with debris accumulation, and its associated effect on available NPSH.

Containment walkdowns have been performed at Ginna in support of the CFD analysis of the susceptibility of the ECCS and CSS recirculation functions to the adverse effects of debris blockage identified in the Generic Letter. Additional walkdowns will be performed during the March 2005 outage using the guidance provided in NEI 02-01, "Condition Assessment Guidelines, Debris Sources inside Containment," Revision 1, which will include sampling for latent debris using guidance in NEI 04-07 and the NRC SER.

Any questions concerning this submittal should be directed to Thomas Harding, Nuclear Safety and Licensing at (585) 771-3384.

VW truly yorI/

Diary rsni

STATE OF NEW YORK

TO WNIT:

COUNTY OF WAYNE :

I, Mary G. Korsnick, being duly sworn, state that I am Vice President - R.E. Ginna Nuclear Power Plant, LLC (Ginna LLC), and that I am duly authorized to execute and file this response on behalf of Ginna LLC. To the best of my knowledge and belief, the statements contained in this document are true and correct. To the extent that these statements are not based on my personal knowledge, they are based upon information provided by other Ginna LLC employees and/or consultants. Such information has been reviewed in accordance with company practice and I believe it to be reliable.

Subscribed and sworn before me, a Notary Public in and flo the State of New York and County of Monrfe

,this L7 day of Mot rch

,2005.

WITNESS my Hand and Notarial Seal:

/J 2

1 I)

Notary Public SHARON L MJU.ER My Commission Expires:

No-P0c,5*dNewYoA Paab No 01 W6017755 Date xc:

Ms. Donna M. Skay (Mail Stop 0-8-C2)

Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission One White Flint North 11555 Rockville Pike Rockville, MD 20852 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 U.S. NRC Ginna Senior Resident Inspector Mr. Carey W. Fleming Sr. Counsel - Nuclear Generation Constellation Generation Group, LLC 750 E. Pratt Street, 17th Floor Baltimore, MD 21202

Mr. Peter R. Smith New York State Energy, Research, and Development Authority 17 Columbia Circle Albany, NY 12203-6399 Mr. Paul D. Eddy Electric Division NYS Department of Public Service 3 Empire State Plaza, 10th Floor Albany, NY 12223