Unit 1, Inservice Inspection Summary Reports
ML050600302
Person / Time
Site: Farley Southern Nuclear icon.png
Issue date: 02/09/2005
From: Grissette D
Southern Nuclear Operating Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
NL-05-0211
Download: ML050600302 (130)


Text

Don E. Grissette Vice President Southern Nuclear Operating Company, Inc.

40 Inverness Center Parkway Post Office Box 1295 Birmingham, Alabama 35201 Tel 205.992.6474 Fax 205.992.0341 SOUTHERN AA COMPANY Energy to Serve YourWorld"'

NL-05-021 1 February 9, 2005 Docket No:

50-348 U. S. Nuclear Regulatory Commission ATfN: Document Control Desk Washington, D. C. 20555-0001 Joseph M. Farley Nuclear Plant - Unit I Inservice Inspection Summarv Reports Ladies and Gentlemen:

Southern Nuclear Operating Company (SNC) submits herewith the Farley Nuclear Plant (FNP) Unit 1, Interval 3, Period 2, Outage 3 Inservice Inspection Summary Report (Enclosure 1) and the Unit 1, Interval 3, Period 3, Outage I Inservice Inspection Summary Report (Enclosure 2). These reports describe and summarize the inservice inspection activities performed during the Unit I Fall 2004 maintenance/refueling outage.

Paragraph IWA-6230 of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code,Section XI, 1989 Edition requires submittal of the enclosed reports.

The supporting inservice inspection documentation, e.g., examination plans and schedules, examination results and reports, examination methods and procedures, evaluation results, and corrective action and repairs, is available for review upon request at Farley Nuclear Plant.

This letter contains no NRC commitments. If you have any questions, please advise.

Sincerely, D. E. Grissette DEG/JLS/sdl

Enclosures:

1. FNP Interval 3, Period 2, Outage 3 Inservice Inspection Report Tabs A, B, and C
2. FNP Interval 3, Period 3, Outage I Inservice Inspection Report Tabs A, B, C, and D An

U. S. Nuclear Regulatory Commission NL-05-021 1 Page 2 cc:

Southern Nuclear Operating Company Mr. J. T. Gasser, Jr., Executive Vice President Mr. L. M. Stinson, Vice President - Plant Farley Mr. J. R. Johnson, General Manager - Plant Farley RTYPE: CFA04.054, LC# 14213 U. S. Nuclear Regulatory Commission Dr. W. D. Travers, Regional Administrator Mr. S. E. Peters, NRR Project Manager - Farley Mr. C. A. Patterson, Senior Resident Inspector - Farley (w/o Enclosures)

(wi/o Enclosures)

(w/o Enclosures)

(,w/o Enclosures)

(w/o Enclosures)

(w/o Enclosures)

Enclosure I Joseph M. Farley Nuclear Plant Inservice Inspection Summary Report FNP Interval 3, Period 2, Outage 3 Inservice Inspection Report Tabs A, B, and C

INSERVICE INSPECTION REPORT Date of Document Completion: January 26, 2005 REFUELING 19 INTERVAL 3 PERIOD 2 OUTAGE 3 J. M. FARLEY UNIT 1 NUCLEAR GENERATING PLANT COLUMBIA, ALABAMA 36319 Commercial Service Date: December 1, 1977 Southern Nuclear Operating Company 42 Inverness Parkway Birmingham, Alabama 35242 (as agent for Alabama Power Co.)

INDEX SECTION TAB FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTION A

BALANCE OF PLANT/REACTOR VESSEL EXAMINATION

SUMMARY

B EXAMINATION PROGRAM PLAN C

EXAMINATION RESULTS D

TAB A Form NIS-1 Owner's Report for Inservice Inspection

Page 1 of 4 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules

1.

Owner Southern Nuclear Operating Comnanv (Name and Address of Owner) 42 Inverness Center Parkway Birminkham. AL. 35242 (as agent for Alabama Power Co.)

2.

Plant J. M. FarlevNuclear Plant (Name and Address of Plant)

Hwv 95 South Columbia. AL. 36319

3.

Plant Unit I

4.

Owner Certificate of Authorization (if required)

N/A

5.

Commercial Service Date 12/01/77

6.

National Board Number for Unit See Listed N. B. for each component

7.

Components Inspected Manufacturer Component or Manufacturer or Installer State or National Appurtenance or Installer Serial No.

Province No.

Board No.

Westinghouse Steam Generator Pensacola ALAD-40307 NIA 73 REHR Heat Joseph Oats &

Exchanger Sons, Inc 2004-1 N/A 475

8.

Examination Dates 04/30/03 to 10/22/04

9.

Inspection Period Identification: Second Period 04/01/01 to 11/30/04

10.

Inspection Interval Identification: Third Interval 12/01/97 to 12/01/07

11.

Applicable Edition of Section Xl 1989 Addenda None

12.

Date/Revision of Inspection Plan: FNP-1-M-097: 09/27/04: Revision 5

13.

Abstract of Examinations and Tests. Include a list of examinations and tests and a statement concerning status of work required for the Inspection Plan. See Tabs B and C

14.

Abstract of Results of Examinations and Tests. See Tab B

15.

Abstract of Corrective Measures. See Tab B Note: Supplemental sheets in the form of lists, sketches, or drawings maybe used, provided (1) size is 8 1I2 in. x 11 in., (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Page 2 of 4 FORM NIS-1 We certify that a) the statements made in this report are correct, b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI, and c) corrective measures taken conform to the rules of the ASME Code, Section XM.

Certificate of Authorization No. (if applicable)

N/A Expiration Date NIA Date /

20 0 Signed Southern Nuclear Operating Co. By

(

sC (Owner)

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Ad and employed by HSB-CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 6/q/>4 to -"/#A4' sand state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in this Owner's Report in accordance with the Inspection Plan and as required by the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, tests, and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions eA-.4 3Levy Inspector'~-

3iture National Board, State, Province, and Endorsements Date L/Z..20 'v

Page 3 of 4 OWNER'S REPORT FOR INSERVICE INSPECTION January 26, 2005 DATE:

OWNER NAME AND ADDRESS:

NAME AND ADDRESS OF NUCLEAR GENERATING PLANT:

NAME ASSIGNED TO NUCLEAR POWER UNIT:

OWNER CERTIFICATE OF AUTHORIZATION:

COMMERCIAL SERVICE DATE:

Southern Nuclear Operating Co.

42 Inverness Parkway Birmingham, Al 35242 (as agent for Alabama Power Co.)

Joseph M. Farley Nuclear Plant Highway 95 South Columbia, Alabama 36319 Joseph M. Farley Nuclear Plant Unit 1 N/A December 1, 1977 NATIONAL BOARD NUMBER:

NAME OF COMPONENTS OR PARTS OF COMPONENTS INVOLVED:

See listed NB's for each component Representative samples of the following components and systems were examined using nondestructive examination techniques.

Page 4 of 4 CLASS 2 COMPONENT OR SYSTEM SYSTEM ALA SKETCH DESIGNATION Steam Generator C B21 2-3300 RHR System ElI 2-3500 RHR Heat Exchanuer Steam Generator Joseph Oats & Co., Inc.

Westinghouse Electric Corporation Camden, New Jersey Pensacola Plant No. 5 Pensacola, Florida INSERVICE INSPECTION DATES:

04/30103 to 11/30104 NAME OF AUTHORIZED NUCLEAR INSPECTOR:

NAME AND MAILING ADDRESS OF INSPECTOR'S EMPLOYER:

Charles G. Ward Hartford Steam Boiler Inspection and Insurance Company of Connecticut One State Street Hartford, CT 06103 ABSTRACT:

SEE TABS B AND C

TAB B Balance of Plant / Reactor Vessel Examination Summary

J. M. FARLEY NUCLEAR PLANT UNIT NO 1 INTERVAL 3 PERIOD 2 OUTAGE 3 BALANCE OF PLANT/REACTOR VESSEL EXAMINATION

SUMMARY

INTRODUCTION An Inservice examination of Class 2 components and piping systems was conducted at Farley Nuclear Plant Unit 1 during October 2004. The examinations were performed in accordance with the approved Examination Program Plan. The primary areas of examination included Steam Generator C, Residual Heat Removal supports. The table documenting the Class 2 examinations is under Tab C of this report.

The program utilized ultrasonic and surface nondestructive testing methods in accordance with the requirements of ASME Section XI 1989 Edition. These examinations are being performed within the one year extension for the second period as allowed by IWA-2400(c).

Selected examinations and related activities were witnessed by representatives of Southern Nuclear Operating Company and its Authorized Inspection Agency. All examinations were performed to the extent practical within geometric and physical limitations.

RESULTS Examinations resulted in no recordable indications areas being noted.

SUMMARY

OF INDICATIONS CLASS 2 VOLUMETRIC EXAMINATIONS There were no reportable Class 2 Volumetric indications.

SURFACE EXAMINATIONS There were no reportable Class 2 Surface indications.

STATUS OF EXAMINATIONS REQUIRED FOR CURRENT INTERVAL This refueling was the 3rd outage, 2Dd period of the 3rd interval and the examinations completed to date represent 100% of the required examinations of the Class I and 2 scope for the current period.

Approximately 63% of the total examinations required for the current interval have been completed.

I

EXAMINATION

SUMMARY

UNIT 1 RF 19 DRAWING IDENTIFICATION VOLUMETRIC SURFACE VISUAL IER ALA2-3300 2R NRI ALA2-3500 3

NRI

TAB C Examination Program Plan

EXAMINATION PROGRAM PLAN UNIT 1 RF 19 INTERVAL 3 PERIOD 2 OUTAGE 3 2004

.91

  • 9 Farley Unit I Class 2 Components

.9 ASME SECTION XI C1.30 C-A Exarm/Cal Sheet No.

Examination/Area ALA2-3300-2R LOWER SHELL BARREL A TO UPPER TUBESHEET Examination Procedure FNP-0-NDE-100.34 Cal Block Results Remarks ALA-56 S04F1UI0i S04FIU102 S04FIU103 S04FMUI04 NRI NRI NRI NRI C2.31 C-B ALA2-3500-3 RESID HX A IN NOZ REINF WELD FNP-0-NDE-1 00.5 S04F1P101 NRI Page: 1 Joseph M. Farley Nuclear Plant Inservice Inspection Summary Report FNP Interval 3, Period 3, Outage I Inservice Inspection Report Tabs A, B, C, and D

INSERVICE INSPECTION REPORT Date of Document Completion: January 26, 2005 REFUELING 19 INTERVAL 3 PERIOD 3 OUTAGE 1 J. M. FARLEY UNIT 1 NUCLEAR GENERATING PLANT COLUMBIA, ALABAMA 36319 Commercial Service Date: December 1, 1977 Southern Nuclear Operating Company 42 Inverness Parkway Birmingham, Alabama 35242 (as agent for Alabama Power Co.)

INDEX SECTION TAB VOLUME I FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTION A

BALANCE OF PLANT/REACTOR VESSEL EXAMINATION

SUMMARY

B EXAMINATION PROGRAM PLAN C

FORM NIS-2 OWNER'S REPORTS FOR REPAIRS AND REPLACEMENTS D

VOLUME 2 EXAMINATION RESULTS E

VOLUME 3 ADDITIONAL EXAMINATIONS F

INDICATIONS G

PERSONNEL, EQUIPMENT, MATERIAL, & CALIBRATION BLOCK H

CERTIFICATIONS EXAMINATION PROCEDURES I

REACTOR VESSEL INSPECTION TOOL DATA AND RESULTS J

CLASS 3 SUPPORTS K

VOLUME I CONTAINS THE INFORMATION TO MEET THE REQUIREMENTS OF ASME CODE 1989 EDITION, SECTION XI, SUBSECTION IWA-6230 FOR SUBMITTAL OF A

SUMMARY

REPORT TO THE NRC FOLLOWING EACH REFUELING OUTAGE.

VOLUMES 2 and 3 CONTAINS THE SUPPORTING DOCUMENTATION FOR THE EXAMINATIONS PERFORMED AND WILL BE RETAINED ON SITE BY FNP.

TAB A Form NIS-1 Owner's Report for Inservice Inspection

Page l of 4 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules

1.

Owner Southern Nuclear OVerating Company (Name and Address of Owner) 42 Inverness Center Parkway Birmingham, AL. 35242 (as apent for Alabama Power Co.)

2.

Plant J. M. Farley Nuclear Plant (Name and Address of Plant)

Hwv 95 South Columbia. AL. 36319

3.

PlantUnit I

4.

Owner Certificate of Authorization (if required)

N/A

5.

Commercial Service Date 12/01/77

6.

National Board Number for Unit See Listed N. B. for each component

7.

Components Inspected Manufacturer Component or Manufacturer or Installer State or National Appurtenance or Installer Serial No.

Province No.

Board No.

Reactor Vessel Combustion CE 69105 N/A 21385 Engineering

]

Class 1 Piping Daniel N/A N/A N/A Construction Class 2 Piping Daniel N/A N/A N/A Construction Steam Generator Westinghouse ALAD-40307 N/A 73 Pensacola

8.

Examination Dates 08/01/04 to 11/13/04

9.

Inspection Period Identification: Third Period 08/01/04 to 12/01/07

10.

Inspection Interval Identification: Third Interval 12/01/97 to 12/01/07

11.

Applicable Edition of Section XI 1989 Addenda None

12.

Date/Revision of Inspection Plan:

FNP-1-M-097: 09/27/04: Version 5

13.

Abstract of Examinations and Tests. Include a list of examinations and tests and a statement concerning status of work required for the Inspection Plan. See Tabs B and C

14.

Abstract of Results of Examinations and Tests. See Tab B

15.

Abstract of Corrective Measures. See Tab B Note: Supplemental sheets in the form of lists, sketches, or drawings may be used, provided (I) size is 8 1/2 in. x 11 in., (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Page 2 of 4 FORM NIS-I We certify that: a) the statements made in this report are correct, b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI, and c) corrective measures taken conform to the rules of the ASME Code,Section XI.

Certificate of Authorization No. (if applicable)

N/A Expiration Date N/A Date ( ° 6 20 0-5 Signed Southern Nuclear Operating Co. By_

(Owner)

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of

-and employed by HSB-CT of Hartford. Connecticut have inspected the components described in this Owner's Report during the period

  • £/0..

to.4/k.r....

and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in this Owner's Report in accordance with the Inspection Plan and as required by the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, tests, and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions 64 Z9 ETA//

Inspector'81SIhature National Board, State, Province, and Endorsements Date

//i20

°5<

Page 3 of 4 OWNER'S REPORT FOR INSERVICE INSPECTION January 26, 2005 DATE:

OWNER NAME AND ADDRESS:

NAME AND ADDRESS OF NUCLEAR GENERATING PLANT:

NAME ASSIGNED TO NUCLEAR POWER UNIT:

OWNER CERTIFICATE OF AUTHORIZATION:

COMMERCIAL SERVICE DATE:

Southern Nuclear Operating Company 42 Inverness Center Parkway Birmingham, AL. 35242 (as agent for Alabama Power Co.)

Joseph M. Farley Nuclear Plant Highway 95 South Columbia, Alabama 36319 Joseph M. Farley Nuclear Plant Unit 1 N/A December 1, 1977 NATIONAL BOARD NUMBER:

NAME OF COMPONENTS OR PARTS OF COMPONENTS INVOLVED:

See listed NB's for each component Representative samples of the following components and systems were examined using nondestructive examination techniques.

CLASS 1 COMPONENT OR SYSTEM SYSTEM ALA SKETCH DESIGNATION Reactor Vessel Bil 1-1100,1-1300 Steam Generator B21 1-3200 Safety Injection System E21 1-4201 Safety Injection System El l 1-4203

Page 4 of 4 CLASS 2 COMPONENT OR SYSTEM SYSTEM ALA SKETCH DESIGNATION RHR System Ell 2-4502, 2-4504, 2-4506,2-4514,2-4517, 2-4518 Ctmt Spray E13 2-4701, 2-4704, 2-4705, 2-4708 CVCS E21 2-4509, 2-4511, 2-4513, 2-4533, 2-4604, 2-5120, 2-4602 HHSI E21 24537, 2-4538, 2-4615, 2-4623, 2-4627, 24631, 2-4636 Main Steam System Nll 2-4101 Steam Generator B21 2-3300 RISK-INFORMED COMPONENT OR SYSTEM SYSTEM RI SEGMENT NUMBERS DESIGNATION RCS B13 IRC-012A, IRC-012B, 1RC-017 IRC-018A, IRC-018B, IRC-018C IRC-020A, IRC-020B, IRC-020C IRC-026C, IRC-032A, IRC-032B IRC-032C, IRC-036A, IRC-036B

_RC-036C, IRC-041A, IRC-054 HYDROSTATIC TESTING:

SEE TAB B NAME AND ADDRESS OF MANUFACTURER OR INSTALLER OF COMPONENTS:

REACTOR VESSEL STEAM GENERATOR Combustion Engineering, Inc.

Westinghouse Electric Corporation Chattanooga, Tennessee Pensacola Plant No. 5 Pensacola, Florida CLASS 1 & 2 PIPING Daniel Construction Co.

Greenville, South Carolina INSERVICE INSPECTION DATES:

08/01/04 to 11/13/04 NAME OF AUTHORIZED NUCLEAR INSPECTOR:

NAME AND MAILING ADDRESS OF INSPECTOR'S EMPLOYER:

Charles G. Ward Hartford Steam Boiler Inspection and Insurance Company of Connecticut One State Street Hartford, CT 06103 ABSTRACT:

SEE TABS B AND C

TAB B Balance of Plant / Reactor Vessel Examination Summary

J. M. FARLEY NUCLEAR PLANT UNIT NO 1 INTERVAL 3 PERIOD 3 OUTAGE 1 BALANCE OF PLANT/REACTOR VESSEL EXAMINATION

SUMMARY

INTRODUCTION An Inservice examination of Class 1 and 2 components and piping systems was conducted at Farley Nuclear Plant Unit I during October 2004. The examinations were performed in accordance with the approved Examination Program Plan. The primary areas of examination included Reactor Vessel Closure Head studs, nuts and washers, Residual Heat Removal/Chemical and Volume Control Piping and supports and Steam Generator trunnions, studs and nuts. The tables documenting the Class I and 2 vessel and piping examinations as well as component supports examined is under Tab C of this report.

The program utilized ultrasonic, surface and visual nondestructive testing methods in accordance with the requirements of ASME Section XI, 1989 Edition.

Selected examinations and related activities were witnessed by representatives of Southern Nuclear Operating Company and its Authorized Inspection Agency. All examinations were performed to the extent practical within geometric and physical limitations.

RESULTS Examinations resulted in recordable indication areas being noted on the basis of procedure recording criteria, which generally are more conservative than specified in the ASME Section XI Acceptance Standards. Indications were evaluated and dispositioned by Indication Evaluation Reports (IER's). A listing of IER's is attached and the data sheets are available at FNP for review. The results are summarized below.

SUMMARY

OF INDICATIONS CLASS 1 (A)

VOLUMETRIC EXAMINATIONS There were no reportable Class I Volumetric indications (B)

SURFACE EXAMINATIONS There were no reportable Class 1 Surface indications.

(C)

VISUAL EXAMINATIONS There were thirty bolted connections from the Class I pressure tests with various degrees of boron accumulation. In each case the boron was removed, any necessary corrective action was performed and either an evaluation or a re-examination found each one acceptable.

Vol 1 Tab B Summary Narrative.DOC 1

CLASS 2 (A)

VOLUMETRIC EXAMINATIONS There were no Class 2 Volumetric indications.

(B)

SURFACE EXAMINATIONS There were no reportable Class 2 Surface indications.

(C)

VISUAL EXAMINATIONS There were four reportable Class 2 Visual indications associated with piping supports. The supports were evaluated by engineering and were acceptable as-is.

Vol 1 Tab B SunimaryNarrative.DOC 2

ADDITIONAL EXAMINATIONS Results from additional examinations which were performed during this outage are as follows:

Class 1 System Leakage Test In accordance with ASME Section XI 1989 Edition IWB-5210(a)(1), leak testing of the Class 1 Reactor Coolant System Pressure Boundaiy was performed prior to startup following the 19th refueling outage. The testing was completed on 11/13/04. A copy of the completed test procedure FNP-1-SOP-1.4 is retained by the FarleyNuclear Plant Document Control.

In addition, to meet the 1989 Section X IWA-5242(a) requirement for removal of insulation from bolted connections in "systems borated for the purpose of controlling reactivity" the alternative exam requirements of Relief Requests RR-27 and RR-42 were used. This RR-27 allowed the insulation to be removed and the bolted connection to be examined for evidence of leakage at static conditions and RR-42 determines the frequency of the insulation removal. If evidence of leakage affecting the bolting was apparent, the bolting was removed and examined per IWA-5250(a)(2) and Relief Request RR-41. The class I leakage test was performed and the code requirements were satisified.

Class 1 and 2 Hydrotesting No hydrostatic testing was performed during the 19th refueling outage to meet requirements of the current inspection interval.

Class 2 Functional/Inservice Testing Class 2 functional testing performed during the 19th refueling outage included portions of the RHR, Containment Spray, Safety Injection and Charging systems. There were ten (10) bolted connections associated with the Class 2 pressure tests with leakage and various degrees of boron accumulation. The boron accumulation was removed and either an evaluation or a re-examination found each one acceptable. Completed data sheets from FNP-l-STP-156.1 are filed in FNP Document Control. The class 2 functional I inservice tests were performed and the code requirements were satisified.

STATUS OF EXAMINATIONS REQUIRED FOR CURRENT INTERVAL This refueling was the Ist outage, 3rd period of the 3rd interval and the examinations completed to date represent approximately 30 % of the required examinations of the Class 1 and 2 scope for the current period. Approximately 68% of the total examinations required for the current interval have been completed.

Vol I Tab B Summary Narrative.DOC 3

EXAMINATION

SUMMARY

)UNIT I RF 19 DRAWING IDENTIFICATION VOLUMETRIC SURFACE VISUAL IER ALAI-1100 CS-I*

NI CS-2 NI CS-3*

NI CS-4 NI

_C S.5*

_N I_

CS-6 NI ALAI-1300 N39-N58 NI S39-S58 NRI W39-W58 NI ALAI-3200 NOI-N32 NI SOI-S32 NI ALAI-4201 QV037B NI ALAI-4203 QV021B NI ALA2-3300 IOR NRI IIR NRI ALA2-4101 MS-R133 NI.

ALA2-4502 SI-R291 (W8)

NRI ALA2-4504 RHR-R98X (W8)

NRI ALA24504 RHR-R98X NI ALA2-4506 RHRIO-R21 NI RHR1O-R21 (W4)

NRI ALA2-4509 CVC-R326 NI ALA2-4511 CVC-R15 NI CVC-R15 (W6)

NI ALA2-4513 CVC-R40 NI CVCS-A22 NI ALA2-4514 SI-R87 NI SI-R87 (W8)

NRI ALA2-4517 RHR8-R52 RI 013 SI-R99 NI ALA2-45 18 SI-R23 NI ALA2-4533 CVC-R80 NI CVC-R80 (WS)

NRI ALA2-4537 SS-2058 NI ALA2-4538 SS-2061 NI ALA2-4602 SI-R91 NIl ALA2-4604 SI-R2 NI ALA2-4615 SS-4001 NI SS4008 NI ALA2-4623 SS-I 975 NI ALA2-4627 SS-1 980 NI ALA24631 SI-R59 RI 012 Sl-R64 RI 010 ALA2-4636 SS-1987 NIl ALA2-4701 CS-R297 RI 011 ALA2-4704 CS-BRIOO NI ALA2-4705 CS4-R8 NI ALA2-4708 CS5-R17 NI ALA2-5120 CS-I NI CS-I (WI)

NRI ALA2-5 120 CS-2 NI CS-2 (WI)

NRI CS-3 NI CS-4 NI

  • Augmented examination Vol 1 Tab B Exam List.doc

ALA

SUMMARY

OF RECORDED INDICATIONS 2004 UNIT IRFI9 ITEM INDICATION ACCEPTED PER IER SKETCH ID DESCRIPTION DESCRIPTION EVALUATION REPAIRIPL MONITOR NUMBER Evidence of leakage and boron N/A multiple Pressure Test 160.3-1 accumulation X

X 001 Evidence of leakage and boron N/A multiple Pressure Test 160.6-1 accumulation X

002 Evidence of leakage and boron N/A multiple Pressure Test 160.12-1 accumulation X

003 Evidence of leakage and boron N/A multiple Pressure Test 160.21.1, 2, 3 accumulation X

004 Evidence of leakage and boron N/A multiple Pressure Test 160.33-1,3 accumulation X

005 Evidence of leakage and boron N/A multiple Pressure Test 160.20-3 accumulation X

006 Evidence of leakage and boron N/A multiple Pressure Test 160.27-1,4 accumulation X

007 Evidence of leakage and boron N/A multiple Pressure Test 160.31.1 accumulation X

-_008 Evidence of leakage and boron N/A multiple Pressure Test 160.15-1, 2,3 accumulation X

009 ALA2-4631 Sl-R64 One Directional Restraint Loose Hanger X

010 ALA2-4701 CS-R297 Sway Strut Bound spherical bearing X

011 ALA2-4631 SI-R59 Sway Strut Bound spherical bearing X

012 ALA2-4517 HRS-R52 Sway Strut Bound spherical bearing X

013 Examination of Class I Evidence of leakage and boron N/A multiple Bolted Connections accumulation X

X 014 Evidence of leakage and boron N/A multiple Pressure Test 160.29-1 accumulation X

015 Evidence of leakage and boron N/A multiple Pressure Test 160.19-1 accumulation X

016 Vol 1 Tab B IER Summary List.DOC

TAB C Examination Program Plan

EXAMINATION PROGRAM PLAN UNIT 1 RF 19 INTERVAL 3 PERIOD 3 OUTAGE 1 2004

40 Farley Unit I Class 1 Components ASME SECTION Xi Exam/Cal Sheet No.

Examination/Area Examination Procedure Cal Block Results Remarks SEC IO

.l,Ea.

_a_

_n_

.e B6.10 B-G-1 ALAI-110OB-BMI VESSEL BOTTOM HEAD EXTERIOR & BMI ALA1-1300-N39-N58 REACTOR VESSEL NUTS ALAI -1300-S39 REACTOR VESSEL STUDS ALAI -1300-S40 REACTOR VESSEL STUDS FNP-0-NDE-100.47 FNP-0-NDE-100.21 EXAM PERFORMED PER WORK ORDER S-03008461. NRI - NO EVIDENCE OF BMI LEAKAGE.

86.30 B-G-1 FNP-0-NDE-100.11I FNP-0-NDE-100.39 FNP-0-NDE-100.1 1 FNP-0-NDE-100.39 ALA-36 ALA-36 S04F1V052 SAT S04F1U027 NRI S04F1U047 NRI S04F1U028.

NRI S04F1U048 NRI B6.30 B-G-1 B6.30 B-G-1 ALA1 -1300-S41 REACTOR VESSEL STUDS FNP.-0NDE-100.11 FNP-0-NDE-100.39 ALA-36 S04F1 U029 S04F1 U049 NRI NRI 86.30 B-G-1 B6.30 8-G-1 ALAI -1300-S42 REACTOR VESSEL STUDS ALAI -1300-S43 REACTOR VESSEL STUDS ALAI -1300-S44 REACTOR VESSEL STUDS FNP-0-NDE-100.11I FNP-0-NDE-100.39 FNP-0-NDE-100.11I FNP-0-NDE-100.39 FNP-0-NDE-100.11I FNP-0-NDE-100.39 ALA-36 ALA-36 ALA-36 S04F1U030 NRI S04F1U050 NRI S04F1U031 NRI S04FIU051 NRI S04F1U032 NRI S04F1U052 NRI 86.30 B-G-1 B6.30 B-G-1 ALA1-1300-S45 REACTOR VESSEL STUDS FNP-0-NDE-100.l i FNP-O-NDE-100.39 ALA-36 S04F1 U033 S04F1 U053 NRI NRI Page: 1

6@

40 Farley Unit I Class I Components ASME SECTION XI ExamlCal Sqheet No.

Examination/Area Examination Procedure Cal Rlock ResuIts

-mArkc SECTION......

fBB___

l{__WM X vI_

Examlatlonlrea B6.30 B-G-1 86.30 B-G-1 B6.30 B-G-1 ALA1 -1300-S46 REACTOR VESSEL STUDS ALAI-1300-S47 REACTOR VESSEL STUDS ALAI -1300-S48 REACTOR VESSEL STUDS ALAI -1300-S49 REACTOR VESSEL STUDS ALAl -1300-S50 REACTOR VESSEL STUDS ALAI -1300-S51 REACTOR VESSEL STUDS FNP-0-NDE-100.1 1 FNP-0-NDE-100.39 FNP-0..NDE-100.11I FNP-0-NDE-100.39 FNP-0-NDE-100.1 1 FNP-0NDE-100.39 FNP-0-NDE-100.1 1 FNP-0-NDE-100.39 FNP-0-NDE-100.1 1 FNP-0-NDE-100.39 FNP-0-NDE-100.1 1 FNP-0-NDE-100.39 ALA-36 ALA-36 ALA-36 ALA-36 ALA-36 ALA-36 S04F1U034 NRI S04F1U054 NRI S04F1U035 NRI S04F1U055 NRI S04F1U036 NRI S04F1U056 NRI S04F1U037 NRI S04F1U057 NRI S04F1U038 NRI S04F1U058 NRI S04F1U039 NRI S04F1U059 NRI 86.30 B-G-1 86.30 B-G-1 B6.30 B-G-1 B6.30 B-G-1 ALA1 -1300-S52 REACTOR VESSEL STUDS FNP-0-NDE-100.1 1 FNP-0-NDE-100.39 ALA-36 S04F1 U040 S04FI U060 NRI NRI B6.30 B-G-1 ALA1-1300-S53 REACTOR VESSEL STUDS ALAI -1300-S54 REACTOR VESSEL STUDS FNP-0-NDE-100.11 FNP-0-NDE-100.39 FNP-0-NDE-100.11 FNP-0-NDE-100.39 ALA-36 ALA-36 S04F1U041 NRI S04F1U061 NRI S04F1U042 NRI S04F1U062 NRI B6.30 B-G-1 Page: 2

6*

Farley Unit I Class 1 Components ASME SECTION XI Exam/Cal Sheet No.

Examination/Area Examination Procedure Cal Block Results Remarks SECTION Xl ExamlnatlonlArea B6.30 B-G-1 86.30 B-G-1 86.30 B-G-1 86.30 B-G-1 B6.50 B-G-1 87.30 B-G-2 ALA1 -1300-S55 REACTOR VESSEL STUDS ALAI -1300-S56 REACTOR VESSEL STUDS ALAI 1300-S57 REACTOR VESSEL STUDS ALAI -1300-S58 REACTOR VESSEL STUDS ALAI -1300-W39 - W58 REACTOR VESSEL WASHERS ALA1-3200-NO1 - N32 STEAM GEN. NUTS FNP-0-NDE-100.11 FNP-0-NDE-100.39 FNP-0-NDE-100.1 1 FNP-0-NDE-100.39 FNP-0-NDE-100.11 FNP-0-NDE-100.39 FNP-0-NDE-100.1 1 FNP-0-NDE-100.39 FNP-0-NDE-100.21 FNP-0-NDE-100.21 ALA-36 ALA-36 ALA-36 ALA-36 S04F1U043 NRI S04F1U063 NRI S04F1U044 NRI S04F1U064 NRI S04F1U045 NRI S04F1U065 NRI S04F1 U046.

NRI S04F1U066 NRI S04F1V053 SAT S04F1V035 SAT B7.30 B-G-2 B5.10 B-F 85.10 B-F ALA1-3200-SO1 - S32 STEAM GEN. STUDS ALA1-4100-14DM SAFE END TO R.V. NOZZLE ALAI 4100-1DM R.V. NOZZLE TO SAFE END FNP-0-NDE-100.21 FNP-0-NDE-100.22 FNP-0-NDE-100.35 FNP-0-NDE-100.5 FNP-0-NDE-100.22 FNP-0-NDE-100.35 FNP-0-NDE-100.5 ALA-RV-7 ALA-RV-7 S04F1V036 SAT S04F1U013 Weld Profile S04F11U014 Weld Profile Page: 3

0o Farley Unit I Class I Components ASME SECTION Xi Examination/Area Examination Procedure ExamrCal Sheet No.

Cal Block Results Remarks SECTION XI ExaminatlorilArea B5.10 B-F ALAI -4200-14DM SAFE END TO RV NOZZLE FNP-0-NDE-100.22 FNP-0-NDE-100.35 FNP-0-NDE-100.5 FNP-0-NDE-100.22 FNP-0-NDE-100.35 FNP-0-NDE-100.5 ALA-RV-7 ALA-RV-7 B5.10 B-F BI250 134-2 B1250 B-M-2 B5.40 B-F B5.10 B-F ALA1-4200-1 DM RV NOZZLE TO SAFE END ALA1-4201-QV037B COPES VALVE ALAl -4203-QV021 B VELAN VALVE ALAl-4205-35DM SAFE END TO PZR NOZZLE ALA1 -4300-14DM SAFE END TO RV NOZZLE ALAI -4300-1 DM RV NOZZLE TO SAFE END ALAl-4500-6DM SAFE END TO PZR NOZZLE FNP-0-NDE-100.23 FNP-0-NDE-IOD.23 FNP4-NDE-100.22 FNP-0-NDE-100.35 FNP-0-NDE-100.5 FNP-0-NDE-100.22 FNP-0-NDE-100.35 FNP-0-NDE-100.5 FNP-0-NDE-100.22 FNP-0-NDE-100.35 FNP-0-NDE-100.5 FNP-0-NDE-1 00.22 FNP-0-NDE-100.31 FNP40-NDE-100.35 APR-I ALA-RV-7 ALA-RV-7 ALA-2 S04F1U015 Weld Profile S04FIU016 Weld Profile S04FIV051 SAT S04F1V050 SAT S04F1 U003 Weld Proffle S04F1U017 Weld Profile S04F1U018 Weld

. Profile S04F1U006 Weld Profile B5.10 B-F 85.40 B-F Page: 4

40 Farley Unit I Class I Components ASME sEcTloN Xi Exam/Cal Sheet No.

Examination/Area Examination Procedure Cal Block Results Remarks SETO

_l E--___aminati___onlw __......__

_.___rea B5.40 B-F B5.40 B-F ALAI -4501 -1DM PZR NOZZLE TO SAFE-END ALAl-4502-1 DM PZR NOZZLE TO SAFE END ALAI -4503-1 DM PZR NOZZLE TO SAFE END ALAI-4504-IDM PZR RELIEF NOZ TO SAFE END FNP-0-NDE-100.22 FNP-0-NDE-100.35 FNP-0-NDE-100.5 FNP)-0NDE-100.22 FNP-0-NDE-100.35 FNP-0-NDE-100.5 FNP-0-NDE-100.22 FNP-0-NDE-100.35 FNP-0-NDE-100.5 FNP-0-NDE-100.22 FNP4-NDE-100.35 FNP-0-NDE-100.5 ALA-5 ALA-5 ALA-5 ALA-5 S04F1U007 Weld Profile S04Ft U009 Weld Profile S04FIUOIO Weld Profile S04F1U011 Weld Profile 85.40 B-F

-5.40 B-F Page: 5.

40 40 Farley Unit I Class 2 Components ASME.

SECTION Xi Exam/Cal Sheet No.

Examination/Area Examination Procedure Cal Block Results Remarks SECTION Xl ExaminationlArea C3.10 C-C C3.10 C-C C3.20 C-C C3.20 C-C C3.20 C-C ALA2-3300-1 OR TRUNNION 1 ALA2-3300-1 I R TRUNNION 2 ALA2-4502-SI-R291 (W8)

WELDED ATTACHMENT ALA2-4504-RHR-R98X (W8)

WELDED ATTACHMENT ALA2-4506-RHR110-R21 (W4)

WELDED ATTACHMENT ALA2-451 1-CVC-R15 (W6)

WELDED ATTACHMENT ALA2-4514-SI-R87 (W8)

WELDED ATTACHMENT ALA2-4533-CVC-R80 (WS)

WELDED ATTACHMENT ALA2-5120-CS-1 (WI)

WELDED ATTACHMENT FNP-0-NDE-100.5 FNP-0-NDE-100.5 FNP-0-NDE-100.5 FNP-0-NDE-100.5 FNP-0-NDE-1 00.5 FNP-0-NDE-100.S FNP-0-NDE-100.5 FNP-0-NDE-100.5 FNP-0-NDE-100.1 1 S04F1 P007 NRI 504F1P008 NRI 504F1 P009 NRI S04F1P010 NRI S04F1P002.

NRI S04F1P003 NRI S04F1P006 NI S04FIP005 NRI S04F1P004 NRI S04F1M001

  • NRI C3.20 C-C C3.20 C-C C3.20 C-C C3.30 C-C Page: 1

es Farley Unit I Class 2 Components 40 ASME SECTION Xl C3.30 C-C ExaminationlArea ALA2-5120-CS-2 (WI)

WELDED ATTACHMENT Examination Procedure FNP-O-NDE-100.11 Cal Block Exam/Cal Sheet No.

Results S04F1M002 NRI Remarks Page: 2

09 40 Farley Unit I Component Supports ASME SECTION Xi F1.40 F-A F1.40 F-A F1.40 F-A F1.40 F-A F1.40 F-A F1.40 F-A F1.20 F-A F1.20 F-A F1.20 F-A F1.20 F-A F1.20 F-A F1.20 F-A F1.20 F-A Examination/Area ALA1 -1100-CS-1 RPV SUPPORT ALA1 -1100-CS-2 RPV SUPPORT ALA1-1100-CS-3 RPV SUPPORT ALAI -1100-CS-4 RPV SUPPORT ALA1 -1100-CS-5 RPV SUPPORT ALAI-1100-CS-4 RPV SUPPORT ALA2-4101-MS-R133 SWAY STRUT (2)

ALA2-4504-RHR-R98X HYDRAULIC SNUBBER (2)

W/ATTACH ALA2-4506-RHRI0-R21 TWO DIRECTIONAL RESTRAINT W/ATTACH ALA2-4509-CVC-R326 TWO DIRECTIONAL RESTRAINT ALA2-4511-CVC-R15 TWO DIRECTIONAL RESTRAINT W/ATTACH ALA2-4513-CVC-R40 ONE DIRECTIONAL RESTRAINT ALA2-4513-CVCS-A22 ANCHOR W/ATTACH Exam/Cal Sheet No.

Examination Procedure FNP-0-NDE-100.23 Cal Block Results Remarks S04F1V029 SAT FNP-0-NDE-100.23 FNP-0-NDE-100.23 FNP-0-NDE-100.23 FNP-0-NDE-100.23 FNP-0-NDE-100.23 FNP4-NDE-100.23 FNP-0-NDE-100.23 FNP-0-NDE-100.23 S04F1V030 SAT S04F1V031 SAT S04F1V032 SAT S04F1V033 SAT S04F1V034 SAT S04F1V039 SAT S04F1V002 SAT S04F1V014 SAT FNP-0-NDE-100.23 S04F1 V015 SAT FNP-0-NDE-100.23 FNP-0-NDE-100.23 FNP-0-NDE-100.23 S04F1V048 SAT S04F1V016 SAT S04F1V017 SAT Page: 1

0 Farley Unit I Component Supports 40 ASME SECTION Xi F1.20 F-A F1.20 F-A F1.20 F-A F1.20 F-A F1.20 F-A F1.20 F-A F1.20 F-A F1.20 F-A F1.20 F-A F1.20 F-A F1.20 F-A F1.20 F-A F1.20 F-A ExaminationlArea Examination Procedure Cal Block ExamlCal Sheet No.

Results Remarks ALA2-451 4-SI-R87 ONE DIRECTIONAL RESTRAINT WIATTACH ALA2451 7-RHR8-R52 SWAY STRUT ALA2-451 7-SI-R99 ONE DIRECTIONAL RESTRAINT ALA2-451 8-SI-R23 ONE DIRECTIONAL RESTRAINT W/ATTACH ALA2-4533-CVC-R80 TWO DIRECTIONAL RESTRAINT WIATTACH ALA2-4537-SS-2058 ANCHOR 2 U-BOLTS ALA2-4538-SS-2061 ANCHOR ALA2-4602-SI-R91 SWAY STRUT ALA2-4604-SI-R2 TWO DIRECTIONAL RESTRAINT ALA2-461 5-SS-4001 TWO DIRECTIONAL RESTRAINT ALA2-461 5-SS-4008 ONE DIRECTIONAL RESTRAINT ALA2-4623-SS-1975 TWO DIRECTIONAL RESTRAINT ALA2-4627-SS-1 980 ANCHOR 2 U-BOLTS FNP-0-NDE-100.23 S04F1V040 SAT

. SAT FNP-0-NDE-100.23 S04F1V018 FNP-0-NDE-100.23 FNP-0-NDE-100.23 FNP-0-NDE-100.23 S04F1V019 SAT S04F1V038 SAT 504F1V049 SAT S04FI V037 FNP-0-NDE-100.23 FNP-0-NDE-100.23 FNP-0-NDE-100.23 FNP-0-NDE-100.23 FNP-0-NDE-100.23 FNP-0-NDE-100.23 SAT 504F1V020 SAT S04FIV021 SAT S04F1V022 SAT S04F1V041 SAT S04F1V042 SAT

. FNP-0-NDE-100.23 S04F1 V043 SAT FNP-0-NDE-100.23 S04F1V044 SAT Page: 2

40 40 Farley Unit I Component Supports 40 ASME SECTION Xi F1.20 F-A F1.20 F-A F1.20 F-A F1.20 F-A F1.20 F-A F1.20 F-A F1.20 F-A F1.40 F-A F1.40 F-A F1.40 F-A F1.40 F-A F1.40 F-A ExamfCal Sheet No.

Examination/Area Examination Procedure Cal Block Results Remarks ALA2-4631 SI-R59 SWAY STRUT ALA2-4631 SI-R64 ONE DIRECTIONAL RESTRAINT ALA2-4636-SS-1987 TWO DIRECTIONAL RESTRAINT ALA2-4701-CS-R297 SWAY STRUT ALA2-4704-CS-BRI00 SPRING CAN ALA2-4705-CS4-R8 TWO DIRECTIONAL RESTRAINT ALA2-4708-CS5-R17 ONE DIRECTIONAL RESTRAINT ALA2-5120-CS-1 CENTRIF CHRGING PMP (C)

Q1 E21 P002C ALA2-5120-CS-2 CENTRIF CHRGING PMP (C) 01 E21 P002C ALA2-5120-CS-3 CENTRIF CHRGING PMP (C)

Q1 E21 P002C ALA2-5120-CS-4 CENTRIF CHRGING PMP (C)

Q1E21PO02C D170292-RM P 1B RMW PUMP OQlP2POOlB-B FNP-0-NDE-100.23 FNP-0-NDE-100.23 FNP-0-NDE-100.23.

FNP4-NDE-100.23 FNP-0-NDE-100.23 FNP-0-NDE-100.23 FNP-0-NDE-100.23 FNP-0-NDE-100.23 FNP-0-NDE-100.23 FNP-0-NDE-100.23 FNP-0-NDE-100.23 FNP-0-NDE-100.23 S04F1V023 SAT S04F1V024 SAT S04F1V045 SAT S04F1V025 SAT S04F1V026 SAT S04F1 V027 SAT S04F1V028 SAT S04F1V00l SAT S04F1V002 SAT S04F1V003 SAT S04F1V004 SAT S04F1V005 SAT Page: 3

0o Farley Unit I Component Supports ASME SECTION XI F1.40 F-A D1.10 D-A Fl.40 F-A D1.10 D-A FI.40 F-A D1.10 D-A F1.40 F-A D1.10 D-A ExaminationlArea Examination Procedure Cal Block ExamlCal Sheet No.

Results Remarks FNP-0-NDE-100.23 D175377-RMW TANK RMW STORAGE TANK 01 P12T503 36 ANCHOR BOLTS ANCHOR D175377-RMW TANK (ATT)

RMW STO TANK Q1 P12T503 36 ANCHOR BOLT RING ATTACHM D175393-SP HX 1A SPENT FUEL HT EXCH Qi G31 H001A-B D175393-SP HX IA (ATT)

SPENT FUEL HT EXCH Q1 G31 HOOIA-B ATTACHMENTS D175451-CCW TANK CCW SURGE TANK Q1P17TO01 D175451-CCW TANK (ATT)

CCW SURGE TANK Q1P17TO01 ATTACHMENTS D175458-CCW HX1B CCW HT EXCH Qi P17HOO1 B-AB 2 SUPPORT SADDLES DI 75458-CCW HX1 B (ATT)

CCW HT EXCH Q1P17HOOIB-AB 2 SUPPORT SADDLES ATTACH S04F1V006 SAT FNP-0-NDE-100.21 FNP4-0NDE-100.23 FNP-0-NDE-100.21 FNP-0-NDE-100.23 FNP-0-NDE-100.21 FNP-0-NDE-100.23 FNP-0-NDE-100.21 S04F1V009 SAT S04F1V007 SAT S04F1V010 SAT S04F1V008 SAT S04F1Vil1 SAT S04F1V046 SAT S04F1V012 SAT

.04F1V047 SAT Page: 4

Farley Unit I Component Supports 3-2-3 ASME SECTION Xi Exam/Cal Sheet No.

Examination/Area Examination Procedure FNP-0-NDE-100.23 Cal Block Results Remarks F1.30 F-A D1.20 D-A HEG-272-AFW-R46 3 DIRECTIONAL RESTRAINT W/ATTACH HEG-272-AFW-R46 (ATT) 3 DIRECTIONAL RESTRAINT ATTACHMENTS HEG-736-AS-A10 ANCHOR WIATTACH HEG-736-AS-AIO (ATT)

ANCHOR ATTACHMENTS S04F1 V101 SAT FNP-0-NDE-100.21 FNP-0-NDE-100.23 FNP-0-NDE-100.21 S04F1V103 SAT S04F1 Vi02 SAT S04F1V104 SAT F1.30 F-A D1.20 D-A Page: 1

TAB D Form NIS-2 Owner's Reports for Repairs and Replacements

Class 1

Form NIS-2 Owner's Report for Repairs or Replacements As required by the provisions of the ASME Code Section Xl RTypc: L1.52 Job Number I

B11-9914 Sheet 1 of 2

1. Owner
2. Plant Unit Southern Nuclear Operating Company Farley Nuclear Plant 40 Inverness Center Parkway Highway 95 South 1

Birmingham, Alabama 35242 Columbia, Alabama 36319 Date (as agent for Alabama Power Company

3. Work performed by Type Code Symbol Stamp Name: Westinghouse Electric Companv LLC N/A Nuclear Services Westinehouse Energv Center Authorization Number Address: P.O. Box 355 Expiration Date Pittsburgh. Pa. 15230-355 N/A
4. Identification of System Qi111, Unit lReactor Vessel and Head 5.

(a) Applicable Construction Code:

ASME Section E 19 98 Edition 2000 Addenda.

NIA Code Case (b) Applicable Section XI Utilized For Repairs Or Replacements, 19 89 Edition N/A Addenda.

N/A Code Case

6. Identification of Components Repaired or Replaced and Replacement Components:

Name of Name of Manufacturer National Other Year

Repaired, ASME Component Manufacturer Serial Number Board Identification Built Replaced, or Code No.

Replacement Stamped (Yes / No)

REACTOR COMBUSTION VESSEL ENGINEERING, CLOSURE HEAD INC.

CE69204 21012 N/A 1972 REPLACED YES WESTINGHOUSE CDRNI ELECTRIC HOUSING (48)

CORP.

618J796G03 M.297 N/A 1972 REPLACED YES WESTINGHOUSE CAPPED CRDNI ELECTRIC HOUSING (8)

CORP.

933D968G01 M.297 N/A 1972 REPLACED YES ROYAL PART LENGTH INDUSTRIES HOUSING E.P.D.

RA.70-144 136 NIA 1972 REPLACED YES ROYAL PART LENGTH INDUSTRIES HOUSING E.P.D.

RA-70.146 138 NIA 1972 REPLACED YES ROYAL PART LENGTH INDUSTRIES HOUSING E.P.D.

RA-70-147 139 N/A 1972 REPLACED YES ROYAL PART LENGTH INDUSTRIES HOUSING E.P.D.

RA.70-148 137 N/A 1972 REPLACED YES ROYAL PART LENGTH INDUSTRIES HOUSING E.P.D.

RA.70.164 135 N/A 1972 REPLACED YES REACTOR MITSUBISHI VESSEL HEAVY CLOSURE HEAD INDUSTRIES, LTD.

B.VH.N04 5846 N/A 2004 REPLACEMENT YES

7. Description of Work The Unit 1 Reactor Vessel Head was replaced in accordance with DCP 03-1-9914, WO# 1039991402, WO# 1039991404, FNP-1-ETP-4488 and FNP-1-ETP-4489.
8. Test Conducted E Hydrostatic E Pneumatic LNormal Operating Pressure E None El Other Pressure 2235 PSI Temperature 547 OF

/

Form NIS-2 Owner's Report for Repairs or Replacements As required by the provisions of the ASME Code Section Xl RType: L1.52 Job Number I Sheet 2 of 2 11-9914

9. Remarks (Applicable Manufacturer's Data Reports to be attached)

The Reactor Head Funnel Replacement was performed by Westinghouse Electric Company in accordancewith procedure MRS-SSP-1691.

The normal operating pressure leak test was performed by SNC per FMP.1-SOP-lA.

Pre-service examination of peripheral CRDM housing welds and lifting lugs were performed by Westinghouse in Futami, Japan. These examinations were witnessed by a SNC representative and an Authorized Nuclear Inservice Inspector and documented in the Replacement Reactor Vessel Head Pre-Service Inspection Final Report Revision 2, WDI-PJF-1302842-FSR.002 Certificate of Compliance We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code.Section XI.

repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization Number_

N/A Expiration Date N/A Signed

-/

,d E.SJMods. Supv.

Date S//-

Ad Owner or Owner's Designee. Title Y

Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of and employed by A56s c7 of At eair-4 eooV7r have inspected the components described in this Owner's Report during the period _

to _

, and state that To the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Z-,'0Z,e-Z Commissions C o-oA T sZ.$

.A/A National Board, State, Province, and Endorsements

,-1b'spectior's Signatuire Date S'

I I

lRecord No.z3of-RYH-/of-42-zz FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES As Required by the Provisions of the ASME Code, Section m

  • Not to Exceed One Day's Production Pg. I of 3
1. Manufactured and certfied by MflSUBISHI HEAVYINDUSTRIES, LTD. KOBE SHIPYARD &MACHINERY WORKS dd -1,WADASAKI-CHO 1-CHOME. HYOGO-KU, KOBE 652-8585 JAPAN Iname and addrwe of NPT Cenftife Hoder)
2. Manufactured for Alabama Power Company/Southem Nuclear Operating Company Address "

(rnm end address of purohaser)

S. Location of Installation Joseph M. Farley Nuclear Plant Unit No.1 7388 N. State Highway 95 Columbia, AL USA 36319 (name ard addresl 4Tye LS-01DAOOI Rev.3 L5-D1DA002 Rev.2 SA508 Gr.3 CLI to 105 ksi 2004 (d-a*V -o nintl.

spec no.)

(lenale renrgthh)

MRN) br buti

5. ASME Code, Section M, Division 1:

1998 A00 1

N525 (etio)

(addenda We) dasl)

(C-ode Cue no.)

6. Fabricated In accordance with Const. Spec. tDiv.2 only)

Revision Date (no.

7. Remariks:

48 control rod drive mechanism (CRDM) penetrations with CRDM assemblies, 2 RVUS penetrations with one-iece housings. 4 instrumentation port penetrations with one-piece housinas. I vent pine. 48 CRDM guide sleeves. 54 housina guide funnels.

infamni li rleflrvri V f4futIa hAnAf nft-trnt nrnnvn A lrrnwnu

-S Mincirr hanri Miinn hirn~ e,,ntlnip Mn ~**

8.

9.

Nom. thickness (in.)

6.37 Min. design thickness (in.)

6.19 Dia. ID (ft & In.)

12'4.82" Lengthoverall(R&in.)

26'7.2 When applicable, Certificate Holders' Data Reports are attached for each item of this report:

National Part or Appurtenance Board No.

Serial Number In Numerical Order (1)

B-VH-N04 5846 (2) below blanki (3)_

(4) 40 Inemess Center Pa rkway P.O.Box 1295/Bin B063

6)

Birmingham, AL USA 35201 (8)

(9)

(10)

  • a ventilation shroud support structure, 58 (12) through-holes for closure studs (13) _ A CRDM assembly consists of the following:

(14)

Pressure housing assembly (15)

- Latch housing (16)

-Rod travel housing 7

4 flux rings

-17 Latch assembly (18)

(19)

(20)

(21)

(22)

(23)

(24)_

National Part or Appurtenance Board No.

Serial Number in Numerical Order (26)

(27).

(28) _

(29)

(30)

(31)

(32)

(33)

(34)

(35)

(36)

(38)

(39)

(40)

(41)

(42)

(43)

(44)

(45)

(48)

(49)

(50)

10. Design pressure 2485 psi. Temp.

650

'F.

Hydro. Test pressure 3191 psi. at tmp.

71 F.

(when applcable)

  • Supplemental htormation In the form of lists, sketches. or drawings may be used provided (1) size Is e '/2 x II. (2) Information In Items 2 and 3 on this Data Report is included on each sheet, (3) each sheet Is numbered and the number of sheets Is recorded at the top of this form.

(798)

This form (E00040) may be obtained from the Order Dept, ASME. 22 Law Drive, Box 2300, Fairfeld. NJ 07007-2300.

RRVCH APC / SNC / Farley Unit-l / P.O.QP030075 / MSt a

Section 2 - Page 1

FORM N-2 (Back-Pg 2 of _)

Certificate Holders Serial Nos.

B-VH-N04 through CERTIFICATION OF DESIGN Design specifications certified by Stephan L Abbott P.E. State PA Reg. no.

030393E tM-appAmlend Design report' certified by David H. Roarty RE. State PA Reg. no.

PE035838E to-appicabl)

CERTIFICATE OF COMPLIANCE Reactor Vessel Closure Head with 48 Control Rod We certify that the statements made In this report are correct and that this (these)

Drive Mechanism conforms to the rules of construclion of the ASME Code,Section III, Division 1.

NPT Certificate of Authorization No.

N-2627 MITSUBISHI HEAVY INDUSTRIES, LTD.

KOBE SHIPYARD & MACHINERY WORKS Expires DECEMBER 8, 2004 Date JYy/. 2o/

Name Signed Fr tCca% HoMIJ (EAttvd r*V*brva)

CERTIFICATE OF INSPECTION 1, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors end the State or Province of 7-E 5

andemployedby Of58 of Cr have Inspected these Items described In this Data Report on /3 UL' 2? oaY

, and state that to the best of my knowledge and berlef, the Certificate Holder has fabricated these parts or appurtenances In accordance with the ASME Code, Section m, Division 1. Each part fisted has been authorized for stamping on the date shown above.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the equipment described in this Data ReporL Furthermore, neither the Inspector nor his employer shal be liable in any manner for any personal Injury or property damage or loss of any kind arising from or connected with this inspection.

Date 7 &Y Signed (°cmc

/2i-Valtutzd NWat kpodoq Commissions AmO /OC7rN 77$4$5 16P<

NarL 3d.puid. rudorneut) ad aem or plv. and no.}

Section 2 - Page 2 RRVCH' APC / SNC / Farley Unit-i / P.O.QP030075 / MIS2

FORM N-2 (3 of 3)

Certificate Holder's Serial Nos.

B-VH-N04 through Manufactured for Alabama Power Company/Southem Nuclear Operating Company Address --

(fai and addres of purchaser)

Location of Installation Joseph M. Farley Nuclear Plant Unit No. 1 7388 N. State Highway 95 Columbia. AL USA 36319 (narme en address)

GENERALASSEMBLY DRAWING 17 GuWide Funnel SA182 1 Pvwok 0rGF16 Guide Funnel Js G3214 1 61 JCi F 0 SUSF304 121 t

,ntgtolr, SA1s2 rr

  • &Ier

!v G,.n16 Latch Assembly 8

Rod Travel Housing SA182 8 NA9"9 eGrXF316 7 Latch Housing SA182 13-f/ -Aq "

G r 316 Head Adapter S8167 6

ERIMT N06690 RVIIS Hood SAM8 5

Adcter Flangee Vent Pipe SB67 KC669Do 4

Sk2TFV16 2

lpure Head SA535 2

Ptin ^ 13o9s TYPEB CLI 1 Clowure Head SA508 Wm DC5PIEN MAIDIAL NOTE This data report covers Control Rod Drive Mechanisms (CRDMs). Drawing no. and Certification of design for CRDMs are shown as follows.

Drawing No.

LS-03BHDO1 Rev.5 Design specifications certified by All L Fakhi P.E. State IL Reg. no.

062-042023 I -appnc-be)

Design report certified by DavId FL Roarty P.E. State PA Reg. no.

PE035838E Wn applicbe)

RRVCH' APC I SNC I Farley Unit-l I P.O.QP030075 / MHI Section 2 - Page 3

Form NIS-2 Owner's Report for Repairs or Replacements As required by the provisions of the ASME Code Section XI RType: L1.52 Job Number B13 -()IV71665901 Sheet I of 2

1. Owner
2. Plant unit Southern Nuclear Operating Company Farley Nuclear Plant 40 Inverness Center Parkway Highway 95 South FNP I Birmingham, Alabama 35242 Columbia, Alabama 36319 Date (as agent for Alabama Power Company)

November 14, 2004

3. Work performed by Type Code Symbol Stamp N/A Name: Southern Nuclear Operating Company Maintenance Department Authorization Number N/A Address:

Joseph M. Farley Nuclear Plant Expiration Date N/A

4. Identification of System Pressurizer Safety 5.

(a) Applicable Construction Code:

ASME Scion Il, 19 71 Edition Winter 1972

Addenda, N/A Code Case (b) Applicable Section XI Utilized For Repairs Or Replacements, 19 89 Edition N/A
Addenda, N/A Code Case
6. Identification of Components Repaired or Replaced and Replacement Components:

Name of Name of Manufacturer National Other Year

Repaired, ASME Component Manufacturer Serial Number Board Identification Built Replaced, or Code No.

Replacement Stamped (Yes / No)

Pressurizer Safety Crosby N56963-01.0012 NIA FNP Purchase Order 1989 Replaced Yes Valve

=

_P3079

=

Pressurizer Safety Crosby N56963-1-002 N/A FNP Purchase Order 1975 Replacement Yes Valve FNP2

7. Description of Work Pressurizer Safety ValveQIB133V03 IC was changed out as regularly scheduled for testign and recertification. Ref: Transaction Number 49113
8. Test Conducted

[1 Hydrostatic

[

Pneumatic Z

NormalOperatingPressure E None F

Other Pressure _

PSI Temperature __

'IF

Form NIS-2 Owner's Report for Repairs or Replacements As required by the provisions of the ASME Code Section Xl RType: L1.52 Job Number B13 - OW71665901 I Sheet 2

of

9. Remarks (Applicable Manufacturer's Data Reports to be attached)

Certificate of Compliance We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl.

repair or replacement Type Code Symbol Stamp NIA Certificate of Authorization Number N/A Expiration Date N/A Signed

{Lernr Maintenance Manager Date

( /L t/

Owner or Owner's Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of

<eCz.9 and employed by A

cq of X.cr,.e.*c 1 7

r have inspected the components described in this Owner's Report during the period a

to 7/

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions 6:

.3 zS

..Z-'A krrpbctor's Signature National Board, State, Province, and Endorsements Date

/_7_/_ -

1_j a,

  • w-1-

-ki 0. -.,i

, J,

_j Z:.. A. ;: %.. !,..,.. ,:,

,;,, :.,.I.; vx /;-.

I

. I IN S.

&IL r~uq ca^-00 W

@-t*}wra

'.;1

- t<',.

.r

_'**--, *l T5

__,5*I g9.'-7J II

. S I

IL t

i

!' =A,

,5la N

,>4;

> t-t~tgd ttt x';

' * }

<~51.i 7r i

'-Y7r 61..

X,,4Xt~s;,

SW rF#

VINE-

}

s A.

?

i}

v ig->_

~~b r w r sj t**

i,'

.f

)g a;

at CrvLbj Vatv

- Ceow'ale C--w.-%

5@i^^s*'=ti3Si4,

sn1, t>;Y1
  • t'?g;*>9@

@s)"s P4+iJ )K bab4..

W440 4;

'i&.

"go e

IO161dU4ois %%A,.s t

Mall<*O%

"*04(

-Nl 0

bw

%1r Li &aw d-AW DIre S" a

tv 24tPA Mb16 V

^We.

r*&-fSt 11%M#WW~

_7 V~i

  • v1-
a g JW }<. *>, W-Awrt stl_

r

,/

w l,

1y ofl_=*

e*_

^,'

. I-

..-- ; P ; i.)'I I..:,.,

Disk, i,.- # - 0 9 I

I 7

v

"', -1.

4 "...

.X

, - A;

,!4_,

1k

-,

&.

a 4 i " -5..t,! e,. v - % ;,, i i r  L, -eI4 m

" i'-

it

ni

  • a
r. ~1-f N

MMM.is 1g,

    • ,it..*t 8'

__A-,

1'^!

- w- %Abdu lS>W ssrr ADsrtzrLv v

>**+>>

Vt!, vz x

11, _

'o

Is

'r*,*

,,,^

?

s {

pri';2!

'r.~,'

N

'i.

-P 0

O'g Va

.zDA r$

a~tb^vtrttt

~ntSl t~.t^9.~

3

.g3>^

Tfi*,>>b V-b%

-A

  • 1'.V a

4 ffi 5_>-t

'%>v;;

9:-'9^5tlb2;htzt L

4l.;Al C..1el t.,::

t~~~~~~~~~~~~

.$u

-wT1 A$*

>~

t9z>etz>

S,-n~

.f; -ft

v. i>.

~

r A

xrE-< Al

-AT ITth 7

a^

,r LrT4L-T-

-Q Li IQ- *.

C-A -Wjp

",IrkH t

C

!n~~R x>;

....v v:w L.

_*t C2WnX, l........ *!.vwnerm ic

.sr

' '1*

<,>}s.,, ;. ' X ~Y-566 MA04 C0<J s e1n

-Ts.s;

}r;

.u:S;.4,;

@.~s.~i,.X, 1-,

w o

'sr

d0 o

O- \\. -F. ~xlet-i C+..............;-s orp.,

-v-->

-c-* le l

t'

  • '~~~~~~~

l t *, *r>

Sc n'tr:S>K1eX*C

),

_~~~~~~~~~~~a

-'*?-

Im

r'*\\t;]tl}\\

4 >t 1..- s<L\\f5 AS:v^

t 2**~2*

^/\\ /. ;/.

R xJS

/.

  • \\

/

\\>

?.1 S t L<< Z _ 4

.' svos53-31-6

  • / m

<.b-S5ss

.?

^:3.b;



xec;4XS-oo.o mo;sss

.t

' * ;.JeSi b' X. ;. ".e

."Ir-A.s3 7 nr 711 l^'

'-b 4

15.'3Cr

^*,

Air Us -.

2.. '

5_,

5,I 6

-c r-

,A;

,c*-

S

  • Form NIS-2 Owner's Report For Repairs Or Replacements As Required By The Provisions Of The ASME Code Section Xl RType: LI.52 U

Job Number E21 -!S400347401 Sheet I of 2

1. Owner
2.

Plant Unit Southern Nuclear Operating Company Farley Nuclear Plant 40 Inverness Center Parkway Highway 95 South FNP I Birmingham, Alabama 35242 Columbia, Al. 36319 Date (as agent for Alabama Power Company)

October 18, 2004

3. Work Performed By Type Code Symbol Stamp NIA Name: Southern Nuclear Operating Company Maintenance Department Authoriztion Number N/A Address:

Joseph M. Farlev Nuclear Plant Expiration Date N/A

4. Identification Of System Chemical and Volume Control System 5.

(a) Applicable Construction Code:

  • Sce sheet 2, 19 Edition
Addenda, Code Case (b) Applicable Section Xi Utilized For Repairs Or Replacements, 19 89 Edition N/A
Addenda, N/A Code Case
6. Identification Of Components Repaired Or Replaced and Replacement Components:

Name Of Name Of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial Number Board Identification Built Replaced Or Code No.

Replacement Stamped (Yes / No)

Mech. Snubber Pacific Scientific 659 N/A P.O. FNP -222 1975 Replaced No Hyd. Snubber Lisega 03615730/046 N/A P.O. QP040545 2004 Replacement No

7.

Description Of Work Snubber SS-2678 was removed from its support by Williams Power Corporation, tested by Wyle Laboratories and was replaced with a Lisega hydraulic snubber by Williams Power Corporation as part of a scheduled upgrade program. Ref: MIF 45858

8.

Test Conducted F Hydrostatic ElPneumatic []

Normal Operating Pressure 3

None [1 Other Pressure PSI Temperature

'IF K

Form NIS-2 Owner's Report For Repairs Or Replacements As Required By The Provisions Of The ASME Code Section Xl RType: L1.52 Job Number I

E21 -S400347401 I Sheet 2 of 2

9.

Remarks (Applicable Manufacturer's Data Reports To Be Attached)

  • Pipe hanger was designed to AISC 1969 ED. requirements and welded to AWS D 1.1-86 requirements using material traceability requirements of ASME Section 111.

Certificate of Compliance We certify that the statements made in this report are correct and this replacement conforms to the rules of the ASME Code,Section XI.

repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization Number N/A Expiration Date N/A Signed

_6 Date i

___/_

Hi_

Owner or Owner's Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ___

and Employed by c

of rqA

-c f-r have inspected the components described in this Owner's Report durng the period to Ah/4/ '

,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions f

ZS

-Z-AA Ipctor's Signature National Board, State, Province, and Endorsements Date

'//sr"/

Form NIS-2 Owner's Report For Repairs Or Replacements As Required By The Provisions Of The ASME Code Section Xl RType: L1.52 Job Number E21 - S400347601 Sheet I of 2 I.

I.

Owner Southern Nuclear Operating Company 40 Inverness Center Parkway Birmingham, Alabama 35242 (as agent for Alabama Power Company)

2.

Plant Unit Farley Nuclear Plant Highway 95 South Columbia, Al. 36319 FNP I Date October 18. 2004

3. Work Performed By Type Code Symbol Stamp N/A Name: Southern Nuclear Omeratine Compant Maintenance Department Authorization Number N/A Address:

Joseph M. Farlev Nuclear Plant Expiration Date N/A

4. Identification Of System Chemical and Volume Control System 5.

(a) Applicable Construction Code:

  • See sheet 2 19 Edition
Addenda, Code Case (b) Applicable Section XI Utilized For Repairs Or Replacements, 19 89 Edition N/A Addenda.

N/A Code Case

6. Identification Of Components Repaired Or Replaced and Replacement Components:

Name Of Name Of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial Number Board Identification Built Replaced Or Code No.

Replacement Stamped (Y es / N o)

Mech. Snubber Pacific Scientific 38378 N/A P.O. QP2244 1988 Replaced No 1Hyd. Snubber Lisega 03615870/ 174 N/A P.O. QP040545 2004 Replacement No

7.

Description Of Work Snubber SS-2679A was removed from its support by Williams Power Corporation, tested by Wyle Laboratories and was replaced with a Lisega hydraulic snubber by Williams Power Corporation as part of a scheduled upgrade program. Ref: MIF 45855

8.

Test Conducted r7 Hydrostatic El Pneumatic E:

NormalOperatingPressure ED None El Other Pressure PSI Temperature OF

Form NIS-2 Owner's Report For Repairs Or Replacements As Required By The Provisions Of The ASME Code Section Xl RType: L1.52 Job Number E21-'

I Sheet S400347601 2 of 2

9.

Remrks (Applicable anufacturer's Data Reports To BeAttached)

  • Pipe hanger was designed to AISC 1969 ED. requirements and welded to AWS D 1.1-86 requirements using material traceability requirements of ASME Section 111.

Certificate of Compliance We certify that the statements made in this report are correct and this replacement conforms to the rules of the ASME Code, Section Xl.

repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization Number N/A Expiration Date N/A Signed Date

/i l

/TV D

Owner or Owner's Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ec z A

and Employed by Ae V3-- -r of AlX C7' have inspected the components described in this Owner's Report during the period

/

/

to

,,/,,Ld.o

,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

ctor's Signature Commissions National Board. State, Province, and Endorsements Date.

/o/

4

Form NIS-2 Owner's Report For Repairs Or Replacements As Required By The Provisions Of The ASME Code Section XI RType: L1.52 Job Number E21 -!;400347901

1. Owner Southern Nuclear Operating Company 40 Inverness Center Parkway Birmingham, Alabama 35242 (as agent for Alabama Power Company)
2. Plant Farley Nuclear Plant Highway 95 South Columbia, Al. 36319 d

U

3. Work Performed By Name: Southern NuclearOveratins ComnanvMaintenanceDepartment Type Code Symbol Stamp N/A Authorization Number N/A Address:

Joseph M. Farley Nuclear Plant Expiration Date N/A

4.

Identification Of System Chemical and Volume Control System 5.

(a) Applicable Construction Code:

See sheet 2.

19 Edition Addenda.

Code Case (b) Applicable Section XI Utilized For Repairs Or Replacements, 19 89 Edition N/A

Addenda, N/A Code Case
6. Identification Of Components Repaired Or Replaced and Replacement Components:

Name Of Name Of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial Number Board Identification Built Replaced Or Code No.

Replacement Stamped

___(Yes I No)

Mech. Snubber Pacific Scientific 38356 N/A P.O. QP2244 1988 Replaced No Hyd. Snubber 1sega 03615870/ 100 N/A P.O. QP040545 2004 Replacenent No

7.

Description Of Work Snubber SS4141A was removed from its support by Williams Power Corporation. tested by Wyle Laboratories and was replaced with a Lisega hydraulic snubber by Williams Power Corporation as part of a scheduled upgrade program. Ref: MIF 45847

8.

Test Conducted M Hydrostatic El Pneumatic El NormalOperatingPressure Z

None Ml Other Pressure PSI Temperature OF

  • F I

Form NIS-2 Owner's Report For Repairs Or Replacements RType: L1.52 As Required By The Provisions Of The ASME Code Section XI Job Number E21 - S400347901 Sheet 2 of 2 9.

Remarks (Applicable Manufacturer's Data Reports To Be Attached)

  • Pipe hanger was designed to AISC 1969 ED. requirements and welded to AWS D 1.1-86 requirements using material traceability requirements of ASME Section 111.

Certificate of Compliance We certify that the statements made in this report are correct and this replacement conforms to the rules of the ASME Code,Section XI.

repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization Number N/A Expiration Date N/A Signed a

Date l_ od_

Owner or Owner's Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of HeTe'c i and Employed by AlS&--c7 of

-A/

e e :7 have inspected the components described in this Owner's Report during the period to A, I'., 4

,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

rCommissions G

4fl}ector's Signature National Board, State, Province, and Endorsements Date

/'

Form NIS-2 Owner's Report For Repairs Or Replacements As Required By The Provisions Of The ASME Code Section XI RType: L1.52 Job Number E21 - S400348001 Sheet I of 2

-m

'I I

W 1.

Owner Southern Nuclear Operating Company 40 Inverness Center Parkway Birmingham, Alabama 35242 (as agent for Alabama Power Company)

2. Plant Unit Farley Nuclear Plant Highway 95 South Columbia, Al. 36319

Date October 18, 2004

3. Work Performed By Type Code Symbol Stamp NIA Name: Southern Nuclear Oneratine Companv Maintenance Department Authorization Number N/A Address:

Joseph M. Farley Nuclear Plant Expiration Date N/A

4.

Identification Of System Chemical and Volume Control System S.

(a) Applicable Construction Code:

  • Sce sheet 2, 19 Edition
Addenda, Code Case (b) Applicable Section Xi Utilized For Repairs Or Replacements, 19 89 Edition N/A
Addenda, N/A Code Case
6. Identification Of Components Repaired Or Replaced and Replacement Components:

Name Of Name Of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial Number Board Identification Built Replaced Or Code No.

Replacement Stamped (Yes / No)

Mech. Snubber Pacific Scientific 38363 N/A P.O. QP2244 1988 Replaced No Hyd. Snubber 11sega 03615870/ 173 N/A P.O. QP040545 2004 Replacement No

7.

Description Of Work Snubber SS-4141 B was removed from its support by Williams Power Corporation, tested by Wyle Laboratories and was replaced with a Lisega hydraulic snubber by Williams Power Corporation as pan of a scheduled upgrade program. Ref: MIF 45846

8.

Test Conducted 1j Hydrostatic [1 Pneumatic M Normal Operating Pressure 3

None a

Other Pressure PSI Temperature OF I

Form NIS-2 Owner's Report For Repairs Or Replacements As Required By The Provisions Of The ASME Code Section XI RType: L152 Job Number E21 - S400348001

' Sheet 2 of 2

9.

Remarks (Applicable Manufacturer's Data Reports To Be Attached)

  • Pipe hanger was designed to AISC 1969 ED. requirements and welded to AWS D 1.1-86 requirements using material traceability requirements of ASME Section ]11.

Certificate of Compliance We certify that the statements made in this report are correct and this replacement conforms to the rules of the ASME Code,Section XI.

repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization Number NIA Expiration Date N/A Signed a

Date at

_Olt

__i_

Owner or Owner's Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of c

At and Employed by ds 7T of

_,Y'A:Cr-,oC5.c have inspected the components described in this Owner's Report during'the period to

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Inspector's Signature Commissions National Board, State, Province, and Endorsements Date

Form NIS-2 Owner's Report For Repairs Or Replacements As Required By The Provisions Of The ASME Code Section XI RType: L1.52 Y

Job Number I

E21 - S400352201 Sheet I of 2

1. Owner
2. Plant Unit Southern Nuclear Operating Company Farley Nuclear Plant 40 Inverness Center Parkway Highway 95 South FNP I Birmingham, Alabama 35242 Columbia, Al. 36319 Date (as agent for Alabama Power Company)

October 26, 2004

3. Work Performed By Type Code Symbol Stamp N/A Name: Southern Nuclear Operatine Company Maintenance Department Authorization Number N/A Address:

Joseph M. Farlev Nuclear Plant Expiration Date N/A

4. Identification Of System Chemical and Volume Control System S.

(a) Applicable Construction Code:

  • see sheet 2, 19 Edition Addenda.

Code Case (b) Applicable Section XI Utilized For Repairs Or Replacements, 19 89 Edition N/A Addenda.

N/A Code Case

6. Identification Of Components Repaired Or Replaced and Replacement Components:

Name Of Name Of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial Number Board Identification Built Replaced Or Code No.

Replacement Stamped (Yes / No)

Snubber Valve Grinnell Unknown N/A P.O. FNP - 222 1976 Replaced No B lock Snubber Valve Grinnell Unknown N/A P.O. QP0456 1968 Replacement No B lock

7.

Description Of Work Snubber CVCS-R528A was removed from its support by Williams Power Corporation, tested by Wyle Laboratories and was reinstalled by Williams Power Corporation. The valve block that did not respond as expected during snubber testing was replaced with an approved equal.

Ref: MIF 50974

8.

Test Conducted

[

Hydrostatic L1 Pneumatic [1 Normal Operating Pressure Z None [] Other Pressure PSI Temperature OF I

Form NIS-2 Owner's Report For Repairs Or Replacements As Required By The Provisions Of The ASME Code Section Xl RType: L1.52 Job Number I

E21 - S400352201 I Sheet 2 of 2

-I

-

9.

Remarks (Applicable manufacturer's Data Reports To Be Attached)

  • Pipe hanger was designed to AISC 1969 ED. requirements and welded to AWS D 1.1-86 requirements using material traceability requirements of ASME Section III.

Certificate of Compliance We certify that the statements made in this report are correct and this replacement conforms to the rules of the ASME Code,Section XI.

repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization Number N/A Expiration Date N/A Signed Date aI/'/oy Owner or Owner's Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of o

and Employed by of AA-e1 Or have inspected the components described in this Owner's Report during the period _

to f__

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions Go Ls Insoctor's Signature National Board, State, Province, and Endorsements Date z/l/',e

Form NIS-2 Owner's Report For Repairs Or Replacements As Required By The Provisions Of The ASME Code Section XI RType: L1S2 V

Job Number I

E21 - S400355201 Sheet I of 2 V

S II.

Owner Southern Nuclear Operating Company 40 Inverness Center Parkway Birmingham, Alabama 35242 (as agent for Alabama Power Company)

2. Plant Farley Nuclear Plant Highway 95 South Columbia, Al. 36319 Unit FNP I Date October 27,2004
3. Work Performed By Type Code Symbol Stamp N/A Name: Southern Nuclear Ooerating Companx Maintenance Department Authorization Number N/A Address:

Joseph M. Farley Nuclear Plant Expiration Date N/A

4.

Identification Of System Safety Injection System S.

(a) Applicable Construction Code:

See sheet2, 19 Edition

Addenda, Code Case (b) Applicable Section XI Utilized For Repairs Or Replacements, 19 89 Edition N/A
Addenda, N/A CodeCase
6. Identification Of Components Repaired Or Replaced and Replacement Components:
7.

Description Of W~ork Snubber SS-4103 was removed from its support by Williams Power Corporation, tested byWyle Laboratories and was reinstalled by Williams Power Corporation. The load stud and load stud nuts damaged during snubber removal were replaced with approved equals.

Ref: MIF 50677

8.

Test Conducted El Hydrostatic a] Pneumatic n NormalOperatingPressure 3

None :] Other Pressure PSI Temperature OF

/

Form NIS-2 Owner's Report For Repairs Or Replacements As Required By The Provisions Of The ASME Code Section Xl RType: L1.2 Job Number E21 -S400355201 I Sheet 2 of 2

9.

Remarks (Applicable Manufacturer's Data Reports To Be Attached)

  • Pipe hanger was designed to AISC 1969 ED. requirements and welded to AWS D 1.1-86 requirements using material traceability requirements of ASME Section 111.

Certificate of Compliance We certify that the statements made in this report are correct and this ASME Code,Section XI.

replacement repair or replacement conforms to the rules of the Type Code Symbol Stamp N/A Certificate of Authorization Number NIA Expiration Date N/A Signed Date

. It/ V q /0 'Y Owner or Owner's Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ace,,,

and Employed by

__r of 4

A b cr have inspected the components described in this Owner's Report during the period

,,,g.

to

,, As

, and state that to the best of my knowledge and belief, the Owner has performed examinations and takeni corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions IiTpEctor's Signature National Board, State, Province, and Endorsements Date -

ZI1111

Form NIS-2 Owner's Report For Repairs Or Replacements As Required By The Provisions Of The ASME Code Section X1 RType: L1.52 Job Number E21 - S400356501 Sheet I of 2

1. Owner
2. Plant Unit Southern Nuclear Operating Company Farley Nuclear Plant 40 Inverness Center Parkway Highway 95 South FNP I Birmingham, Alabama 35242 Columbia, Al. 36319 Date (as agent for Alabama Power Company)

October 14, 2004

3. Work Performed By Type Code Symbol Stamp N/A Name: Southern NuclearOneratineComnani'MaintenanceDenartment Authorization Number N/A Address:

Joseph M. Farlev Nuclear Plant Expiration Date N/A

4. Identification Of System Chemical and Volume Control System S.

(a) Applicable Construction Code:

  • See sheet 2, 19 Edition
Addenda, Code Case (b) Applicable Section Xl Utilized For Repairs Or Replacements.

19 89 Edition N/A

Addenda, N/A Code Case
6. Identification Of Components Repaired Or Replaced and Replacement Components:

Name of Name or Manufacturer National Other Year Repaired ASME Component Manufacturer Serial Number Board Identification Built Replaced Or Code No.

Replacement Stamped

_ _(Yes I N o)

Pivot Pin Pacific Scientific Unknow N/A P.O. FNP 222 1975 Replaced No Pivot Pin Pacific Scientific N2561 N/A P.O. QP1536 1987 Replacement No

7.

Description Of Work Snubber SS-4623A was removed from its support by Williams Power Corporation. tested by Wyle Laboratories and was reinstalled by Williams Power Corporation. The pivot pin damaged during snubber removal was replaced with an approved equal.

Ref: MIF 49146

8.

Test Conducted M Hydrostatic E1 Pneumatic M NormalOperatingPressure 3

None M Other Pressure PSI Temperature OF

Form NIS-2 Owner's Report For Repairs Or Replacements As Required By The Provisions Of The ASME Code Section Xl RType: L1.52 Job Number E21 -

ISheet 2

S400356501 of 2

9.

Remarks (Applicable Manufacturer's Data Reports To Be Attached)

  • Pipe hanger was designed to AISC 1969 ED. requirements and welded to AWS D 1.1-86 requirements using material traceability requirements of ASME Section 111.

Certificate of Compliance We certify that the statements made in this report are correct and this ASME Code, Section Xl.

Type Code Symbol Stamp replacement conforms to the rules of the repair or replacement N/A Certificate of Authorization Number Signed N/A Expiration Date

  • N/A YU&t7U--

Date l L v

I Owner or Owner's Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of God,,_

and Employed by

- c of

',eri o,-

r have inspected the components described in this Owner's Report during the period to __/__/_,__

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taked corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

-l=*tor's Signature Commissions National Board, State, Province, and Endorsements Date

/

Form NIS-2 Owner's Report For Repairs Or Replacements As Required By The Provisions Of The ASME Code Section X1 RType: L1.52 Job Number I

E21 - S400356601 Sheet I of 2 r

'U

'U

1. Owner Southern Nuclear Operating Company 40 Inverness Center Parkway Birmingham, Alabama 35242 (as agent for Alabama Power Company)
2. Plant Farley Nuclear Plant Highway 95 South Columbia, Al. 36319 Unit FNP I Date October 14,2004
3. Work Performed By Type Code Symbol Stamp N/A Name: Southern Nuclear Operatin2 Comuanv Maintenance Department Authorization Number N/A Address:

Joseph M. Farley Nuclear Plant Expiration Date N/A

4. Identification Of System Chemical and Volume Control System 5.

(a) Applicable Construction Code:

  • See sheet 2, 19 Edition Addenda,'

Code Case (b) Applicable Section XI Utilized For Repairs Or Replacements, 19 89 Edition N/A

Addenda, N/A Code Case
6. Identification Of Components Repaired Or Replaced and Replacement Components:

Name Of Name Of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial Number Board Identification Built Replaced Or Code No.

Replacement Stamped (Yes / No)

Pivot Pin Pacific Scientific Unknown N/A P.O. FNP - 222 1976 Replaced No Pivot Pin Pacific Scientific N2561 N/A P.O. QP1536 1987 Replacement No

7.

Description Of Work Snubber SS-4623B was removed from its support by Williams Power Corporation, tested by Wyle Laboratories and was reinstalled by Williams Power Corporation. The pivot pin damaged during snubber removal was replaced with an approved equal.

Ref: MIF 49143

8.

Test Conducted

[ Hydrostatic

[]

Pneumatic M] Normal Operating Pressure E

None [] Other Pressure PSI Temperature OF

Form NIS-2 Owner's Report For Repairs Or Replacements As Required By The Provisions Of The ASME Code Section M RType: L1.52 Job Number E21 -S400356601 ISheet 2 of 2 U

W

9.

Remarks (Applicable Manufacturer's Data Reports To Be Attached)

  • Pipe hanger was designed to AISC 1969 ED. requirements and welded to AWS D 1.1-86 requirements using material traceability requirements of ASME Section III.

Certificate of Compliance We certify that the statements made in this report are correct and this ASME Code. Section Xl.

replacement repair or replacement conforms to the rules of the Type Code Symbol Stamp N/A Certificate of Authorization Number Signed.

a N/A Expiration Date N/A Date

'at e lo

/

Owner or Owner's Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Gaff and Employed by A'oS5,-

Ce of

^

v 7 have inspected the components described in this Owner's Report during the period

.,/<.

to _

_/

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions if fl

..ZytA d

spector's Signature National Board, State, Province, and Endorsements Date

Class 2

Form NIS-2 Owner's Report for Repairs or Replacements As required by the provisions of the ASME Code Section Xl RType: L1.52 Job Number E21 - 1040290101 Sheet I of 2 v

U i

_w

. Owner Southern Nuclear Operating Company 40 Inverness Center Parkway Birmingham, Alabama 35242 (as agent for Alabama Power Company)

2. Plant Unit Farley Nuclear Plant Highway 95 South Columbia, Alabama 36319 FNP I

Date November7. 2004

3. Work performed by Type Code Symbol Stamp N/A Name: Southern Nuclear Operatin2 Company Maintenance Department Authorization Number N/A Address:

Joseph M. Farlev Nuclear Plant Expiration Date N/A

4. Identification of System Charging System S.

(a) Applicable Construction Code:

ASME Section Ill, 19 68 Edition N/A

Addenda, N/A Code Case (b) Applicable Section Xi Utilized For Repairs Or Replacements, 19 89 Edition N/A Addenda.

N/A Code Case

6. Identification of Components Repaired or Replaced and Replacement Components:

Name of Name of Manufacturer National Other Year

Repaired, ASME Component Manufacturer Serial Number Board Identification Built Replaced, or Code No.

Replacement Stamped (Yes / No)

Disc Velan UNKNOWN*

N/A FNP Purchase Order 1973 Replaced No

_FNP2 Disc Velan 6861 N/A FNP Purchase Order 1994 Replacement' Yes 0~~P941 566

_II I.

_I_

7. Description of Work The disc in the l B Charging Pump Discharge Check Valve (QIE2I V0122B) was replaced with an upgraded disc to preclude the failure of the check valve seat and anti-rotation nubs. This was a result of the root cause corrective action from CR 2004002293. RER 1040560501 provided the reconciliation for the new disc. (Ref: Transaction Number 46988) p
8. Test Conducted D Hydrostatic El Pneumatic

[9 Normal Operating Pressure LI None [] Other Pressure PSI Temperature

`F

.7

Form NIS-2 Owner's Report for Repairs or Replacements As required by the provisions of the ASME Code Section XI RType: L1.52 Job Number E21 -

I Sheet 2 of 2 1040290101

-W

9. Remarks (Applicable Manufacturer's Data Reports to be attached)
  • Since the original valve was manufactured to the 1968 Draft Pump and Valve Code, no data report was supplied, and the original disc serial number is unknown.

The serial number for the complete valve is 207 as identified on the Oualitv Release supplied by Westinghouse at the time of installation..

Certificate of Compliance We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl.

repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization Number N/A Expiration Date NIA Signed Maintenance Manager Date 1/7 lo S Owner or Owner's Designee. Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of GCefcEw and employed by fC5s3'- CT of A"e erC

, C c~c e7' ce7-have inspected the components described in this Owner's Report during the period

___5_

to

/

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

h_°_/

Commissions

.-A "Zg

.:Z LI/A Jmt~to s Signature National Board, State, Province, and Endorsements Date

C'-

-I d.

FORM N-2 CERTIFICATE HODER8D"'tA REPORT FOR DENTICAL S NUCLEAR PARTS AND APPURTENANCESS' As Required by the Provisions of the ASME Code. Section iII 2

Not to Exceed One Day's Production Pg.1 of 2 I Marufacturedandcertnifedby _ELAN4 INC.

550 McARTH2 Ti__EET.

MOHTREAL.

PO H4IT_1X8 CANADA P2-79936-NSP ITEM-03

^e...

e4~ `41,,

of WI C."nhie M~I

2. Manfactutedlor ALABAMA POWER COMPAMY P.O.BOX 1295 BIRMINGHAM.

ALABAMA 3.5201 fQP941566.

~*Io 41

3. Locateonoflrnstallataon APCO:

FARLEY HUCLEAR PLANT HIGHWAY 95 SOUTH. COLUMBIA AL. 3i

-j19 USA

4. Typ 78431 / C SA-182 F316 75,000 PSI(MIN)

N/A 1994 n* o I i-..iI 111,0ce

  • `9 I.,gsut#

s,ivril ICANI its...

6. ASME Code, Section il Division 1 -1971 SUMMER'71 1

N/A

6. Fabricated in aCCane tiFCnt SoEc IALY N/A nevisoon N/A Date NOTE F4UL rat EXCEI9~

F 0S T9RE SEC.TIT PAR T-A

7. Re.rk.:

CODE EDITION 1989'ADDENDA:

HONE_

"DISC" HEAT No.: 39024/T5382 S.

9.

SPARE PARTS FOR 3"-15OOk BOLTED COVER SWING CHECK VALVES (WID 03C88)

Non. thickness (n.)

N/A Mn. des gn thickness fin.I N/A Die. ID MIt So In.)

tW/A Length oveft lit If I & o ln/A When applicable. Ceatnicete Holders Data Reponts are attached for each item of this report:

Part or Appurtenance Ntalinal Serial Number Bnoard No in Numerical Order DISC SN: i686U/A t2..... PSC SN: '6@L... ___

(14--

1.

(5) 191

~-

(Il (133,

,11

-1 i-.--- -

5It Pat or Appurtenance Nationlt Serial Number Board No In Numerical D Jet (281 129_

1311 1323 _-

(323 (331 (34 (40)~

1423 (4 3 31 (441 4 5)

(487) 14 7)

(504 I. ?l (15_

'19)

"-n%

svg bb 1211 W2) 123)

(241 (251 Yrr.^7.,^

T--

rer.

^

¶0. 00e9igapressaure ZUU ItMAX.

Ot um.

bI(J (MAK..

OF.

Hdro lst preassure N/A at temp. "F

  • Sra.lnems,~e voittrmt.on onthe to-enof usts. sketch~es a-d&a..ngs may be sitrd ptavuded III siroe.4 L.

W tt. (21 inmefo,etlerIn hte'yl 2 srid 3 eA tim-a Odta 111spor W NCtwd~d O"Wi h Shoet. 131 se(PI Shoot is rouw.oerod sd tie nsiml-tmci Of IheetI. 'B el~clodd St the top Of this (o'..

2115)l Ti, loom IIC000401 iv Its beobtvnfed Iron' the Cidul Dept.. ASME. 2 2 Law Oril.. Sos 2300. Feter(41d. NJ 07007.2 200.

1! I i MOMM 1, FRIMI-111TIM "WIGN90M

ffa&"

FORM MN2 (Back - Pg. 2 of_.2.J 9

4 j 22.

CEftt.f;cal 14-.tdvr Sel'al Nuzs

()t..(.'t5

!j stswough.

CtRWICAIIOU OF OISIGN

! D%4J I.C.C.

N..v..f.:.I

-AI.O..PPLi.

ICALE t

r s,.

./A I

Fte;n._

tal U*'g D¢eaijv><tt

  • cJl.I.Ad t.,

.j~.

. {!)!.QVI.ED P

l ntl

!'p;r t4!

.~~.

1*e 1*tintt 4 UCtNTIFICAlt OF COMPLIANCE j41 WP

¢.;;

.U t TINci InC J t

portoll et.urqcjan tha this Ita fi

)

^1w°2/~~~~~1A 9t tSe s;cJECB9

1. the undtoi gnod, tholdtnq a va~lid eommismo-
  • s.:d by " N**l

.ord Of Bdw nd Pt.6urt V*ssel Inspelor nd thoState v Pec y e of L

ISf~

nd employed by t_

etf~t hove lnwp

¢ted these Itemns deo scrittJ in this Doe ICrto OO

_on on oWnd st 141t titatI l

twsl of rny knowledge and tq!wli the Cc titicate Holder has iabricato ite ie part& or sppurt nisca in accordtnce with the ASME Code Seetion Ill. D w sgran 1. EdCh part listed has Men cuthoriznd ior Stoirping on the dttat shown abovlr fly &.giung Ithis cortificas. incitha ins Lnspeetor rici hl emTployer makes *nir wocranty, exptssed or rnplicd. Concorning the oquviprnt deJslbed

i. tu% Dte& RAepdr. Fuithirdln cn naitd r the inspactor not he n aiyt l Dar bof liable in ny manner for any personal indury ow Property damPoe of blss of my knid aritig itorn or cot uthd Zi th is nncpoea on te F

A SE Cd@Sco It.Drtarr

.Eahpr lis het tee Suto:dlot )tltip flC Ott th d-t ihorelsinx abova.\\4 Bta oENOIT FRADETTE r

Wit

~

2./%I-Sr12

~

Commiss ions iA'.i44...4.C 1,k 4I C

s..

  • Formi NIS-2 Owner's Report for Repairs or Replacements As required by the provisions of the ASME Code Section XI RType: L1.52 U

Job Number G21 - 1040818901 Sheet I of 2

i.

--I

1. Owner Southern Nuclear Operating Company 40 Inverness Center Parkway Birmingham, Alabama 35242 (as agent for Alabama Power Company)
2. Plant Farley Nuclear Plant Highway 95 South Columbia, Alabama 36319 Unit FNP I

Date 11/10/04

3. Work performed by Type Code Symbol Stamp N/A Name: Southern Nuclear Operating Company Maintenance Department Authorization Number N/A Address:
  • Joseph M. Farlev Nuclear Plant Expiration Date N/A
4. Identification of System Liquid Waste Disposal System S.

(a) Applicable Construction Code:

ASME Section III, 19 71 Edition Summer 1972

Addenda, N/A Code Case (b) Applicable Section XI Utilized For Repairs Or Replacements, 19 89 Edition N/A
Addenda, N/A Code Case
6. Identification of Components Repaired or Replaced and Replacement Components:

Name of Name of Manufacturer National Other Year

Repaired, ASME Component Manufacturer Serial Number Board Identification Built Replaced, or Code No.

Replacement Stamped (Yes I No)

Plug MTr Hammer Dahl 1819-1 N/A FNP Purchase Order 1976 Replaced Yes FNP-269 Plug 1TT Hammer Dahl D9362-8 N/A FNP Purchase Order 1984 Replacement Yes

~26194

7. Description of Work The Containment Sump Discharge Valve (QIG2I HV3376) was found tobe leaking past its seat during LLRT. Upon disassembly, it was determined that the valve plug required replacement. Ref: Transaction Number 49566

-I

8. Test Conducted El Hydrostatic a

Pneumatic ID Normal Operating Pressure R

None a

Other Pressure PSI Temperature O__

F

Frorm NIS-2 Owner's Report for Repairs or Replacements As required by the provisions of the ASME Code Section M RType: L1.52 Job Number G21 - 1040818901 I Sheet 2 of 2 I.

_rW

9. Remarks (Applicable Manufacturer's Data Reports to be attached)

Certificate of Compliance We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code,Section XI.

repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization Number N/A Expiration Date N/A Signed H

Maintenance Manager Date 1 U/' L/

Owner or Owner's Designee, Title P

Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of G

,v and employed by

- c1 of C

S ca~r

-have inspected the components described in this Owner's Reportduring the period Ar2 ad,,<'

to

,/5./

S

,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

1-/_1 J

I'-a'-

,+wiector's Signature Commissions d4-x -T Z S rAz National Board, State, Province, and Endorsements Date 5

FORM N-2 NPT CERTIFICAYE h6LDERSrnAATAR POU R PART$ AND TPPU AT9NANCES#'...5 AsReTied O1F O

NUCLER

-AA N 4 1 PJThACS 4-i Code Ru S

i l'v. 1'

1. (a) Manufactred byv HAMEL DAhL, INC.

175 POST ROAD',ni4ARW1CK;'^Rl'.tt: '02888"I ^'?

"I"j (Name and addres of NPT Certificate Holder)

K (b)

Manufactur d for ALABAMA POWER CO;.

lName and addrs of N Certificate Holder for.ompleted nuclear component)

2. ldantificatlon-Ctrtlficat.Holder's SrlalNo. pstD9362-7 T}IRU tl
d. No.

WA CN No. NA (a) Constructed According to Drawing No.

1 9979 Drawing Prepered by RAML _ DAHL.

INC.

lb) Description of Part InsPected FnOUR (L4)

VALT U PT TWC c) Applicable ASME Code: Section iII, Edition.-

1.7I

AddendsdateGTjh

.792 CaseNo NlA Clas

3. Remarks:

SPARF PARTS (Brief description of service for which component was designed.)

Item 4-8 Inclusive to be completed for single will vessels, lackets of jacketed vessels, or shello of heat exchangers.

4. Shell:

Material __

T.S.

Nom.Thk.IJn. Corr.Allow.lin. Diam._ft..In. Length-.t.-In.

(KInd Spec. No.)

Min. of range epecilled)

S. Seems: Long H.T.

R. T.

Efficiency Girth H.T._

R.T.

No. ot Courses S.

Heeds: (a) Material _T.S.

Ib) Material T.S. _

Location ftop.

Crown Knuckle EliIptIcal Conical Wemispherical Flat Side to Pressure bottom. ends)

Thickness Itadlus Radius Patio Apse Angle Radlus Dim.

(convex or concave)

,_(a)

(b)

If removable, bolls used OtheI astening (Material. Spec. No.. T.S., SIte. Number)

(Describe or attach sketch)

~

7. Jacket Cloturt:,

aDescribe as oge* end weld, bar. etc. It bar, gIve dimensions, If bolted, describe or sketch)

8. (a) Design Pressure' psi at
  • F fb) Mn. Pressure-Test Temp.

r Items 9 end 10 to be completed lop tube sections.

9. Tube Sheets: StAtionary: Material Diarn.

in. Thk. _in.

Attachment IKInd I. Spec. No.

(subject to pre.) IWaIdaed.

bolted)

Floating:

Material Dism in. Thk.

In. Attachment

10.

Tubes: Material O.D.

In. Thk._

in. or gage Number Type (Stralght or U)

Item% 1t1-t4 inclusive to be completed for inner chambers of jacketed vessels or channels of heat e rchengers.

It.

Shell Material T.S.

Nom. Thk.

in. Corr. Allow. Jn. Diam. ftlin. Lengthft.tin.

iKinds 1 Spec. No.)

(Min. of range specilleri 12 Smans Long H..T.

R. T.

Efficiency Grrth.

H.

H.T.'_ -

RTR.T.

No.of Courses

13.

teeas Ila) Material

_TS.

lb) Material _

T.S.

Crown Knuckle Elliptical Conical Hemisphericel Flat Side to Pressure Location Thickness Radius Radius Ratio Apea Angle Radius Diem.

(convex or concave)

(a) Top. bottnm, ends Ith) Channel it rernovai.le. olls used ia b)

______i Ic)

Other fattening eot IDescritb or attach skelch)

'4 Is) Design Presiur_

psi at

  • F ib) Mm. Pressure-Tast Temp.

F t t potsweld hedl lealoea List nther Internal or esatrnal pressures with coincident temperature when applicable.

5ulipioensnIai Sheol% in form of lists, sketches. or drawings may De used PrOvidedi iII Site Is Svi in. a 11 In.1 ?2) information in Items I anda ot this DOat Report is 1neluode on ach sneetsl and (31 each sheet is numbered *nd numcor of sheets Is recorded in Item 3. Remarks.

I I 2 ltfl This form IEi000U4U) may be obtained from the Order Dept.. ASME. 345 E. 47th St.. New York. N.Y. 10017

Ieselw obec pktdorlleslsv repliae.

IL Sfety Vhi Outlets: Number Sixe Location_

IL Nozzles:

Purso, linlet.

teltntoo *Mnt ulet. drain)

Number DiemO or Size Type Materiel Thicknees Material How Attacd t7. InspectJon Manholes:

No.

Size Loostion_

Openings: Handholes:

No.__

Size Location Threeded:

No.

Size Location IL Supporu: Skirt Lugs Leg-s Other Attached Yes ow no)

(Number)

(Number)

(Deecrit.)

£wherv a how)

We crity that tth statnmntt mad In thils rpon ar orrect and this vesel prt or apurtenance ft defind in the Code conformt to tse riut of constnuction of the ASME Code. Section Ill.'

(The applicable Design Specification and Design Report are not the reponsibility of the NPT Certificatt Holder for parts An NPT Certificatt Holder for appurtenances is responsible for furnishing a separate Design Specification and Dtsign Report if the appurtt-nance Is not Included in the component Detsign Specification and Design Report.)

Det, SEPTU MBER 28, 19841i Signedt MFTf ])ANIl-TNr

-BY INPT Cerifficate Holder)

D.A.OUELLETTE, Q.A. IANAGER Ctrtiticate o Authorization Exoir s.1qA6 Certificat of Authorization No.

CERTIFICATION OF DESIGN FOR APPURTENANCE (when applicable)

Design Information on file at HAIEL DAHL, INC.

Streu enalysis report on file at N/A Design soecificat;ons certified by R.E.

SODERBERG Prof. Eng. State MA Reg. No. 1Lt473 2..

Stress analysis report certified by N/A Prof. Eng. Sutte Reg. No.

CERTIFICATE OF SHOP INSPECTION

1. the undersigned, holding a valid commis).j1stsued by the National Board of Boiltr and Pretture Veswel Inswectors and the State or Provinet of an-'_T nd emoIoyed by I -1 THR RMe ft ITT1 I A AeIIAI TN-rn of I ON' CR l

have Inspecsed the pert of a pressure vessel described in this Partial Data Report on 9

.194

. and state that. to the best of my knowltege and belief. the NPT Certificate Holder has constructed this part in accordance with the ASME Code. Section 111.

By signing this certif cate.

neither the Inspector nor his employer makes any warranty. *xprensed or Implied, concerning the part ce.

scribed in this Partial Data Report. Furthermore, neither the Inspector nor hit employer shall be lilble in any manner for any personal Injury or property damage or a loss o anry kind arising from or connected with this insoection.

Date S

Commissions di §21?

sieCto e ignnaqure National Btoar.

state. Province anc No.

Form NIS-2 Owner's Report for Repairs or Replacements As required by the provisions of the ASME Code Section Xl RType: L1.52 U.

Job Number E21 - 1040897801 Sheet I of 2 1

'154

_1.

Owner Southern Nuclear Operating Company 40 Inverness Center Parkway Birmingham, Alabama 35242 (as agent for Alabama Power Company,

2. Plant Farley Nuclear Plant Highway 95 South Columbia, Alabama 36319 Unit FNP I Date October 19.2004
3. Work performed by Type Code Symbol Stamp N/A Name: Snuthern Nuclear Operatine Companv Maintenance Department Authorization Number N/A Address:

Joseph M. Farlev Nuclear Plant Expiration Date N/A

4. Identification of System Chemical Volume And Control System 5.

(a) Applicable Construction Code:

ASME Section ll, 19 71 Edition Summer 1971

Addenda, N/A Code Case (b) Applicable Section XI Utilized For Repairs Or Replacements, 19 89 Edition N/A
Addenda, N/A Code Case
6. Identification of Components Repaired or Replaced and Replacement Components:

Name of Component Name of Manufacturer Manufacturer Serial Number National Board No.

Other Identification Year Built

Repaired, Replaced, or Replacement ASME Code Stamped (Yes / No)

WI t

I I

I Studs Unknown UNKNOWN N/A Q-l -E21-CCA-26 Unk Replaced No Nuts Unknown UNKNOWN N/A Q-l-E21-CCA-26 Unk Replaced No Studs Mackson Inc.

S20751 N/A FNP Purchase Order 2004 Replacement No

_P040263_

Nuts Korea Bolt C91060 N/A FNP Purchase Order 2002 Replacement No QP040363

7. Description of Work During the performance of an ASME Section Xl pressure test, boron was found at the joint of flow orifice NIE21FE972. All studs and bolts were replaced with new studs and bolts. Ref: Transaction Number 49644 I..
8. Test Conducted a1 Hydrostatic R Pneumatic LI Normal Operating Pressure Z

None E1 Other Pressure PSI Temperature

Form NIS-2 Owner's Report for Repairs or Replacements As required by the provisions of the ASME Code Section XI RType: L1.52 Job Number E21 - 104089780i ISheet 2 of 2

9. Remarks (Applicable Manufacturer's Data Reports to be attached)

-I

9. Remarks (Applicable Mlanufacturer's Data Reports to be attached)

Material specifications for original bolting material was determined from a review of SSI 109-2. Original CMTR's could not be found.

Heat Number for new nuts is C91060 as listed. The Heat Code for new nuts is JQB.

Certificate of Compliance We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl.

repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization Number N/A Expiration Date N/A Signed Maintenance Manager Date Amlt/L aO Owner or Owner's Designee. Title U

I Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of 6:

,4 and employed by 5-.sR-C* 7 of A~AIC4

.~t C-co have inspected the components described in this Owner's Report during the period to

,/4.s and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Com~missions lnfector's Signature C

ss 7

£ 2-.A National Board, State, Province, and Endorsements Date

//d4/

Form.NIS-2 Owner's Report for Repairs or Replacements As required by the provisions of the ASME Code Section X1 RType: L1.52 Job Number I

E21 -I1040898001

_r-I

1. Owner Southern Nuclear Operating Company 40 Inverness Center Parkway
2. Plant Farley Nuclear Plant Highway 95 South Columbia, Alabama 36319 I

V

3. Work performed by

-Name: Southern Nuclear Operatine Company Maintenance Department Type Code Symbol Stamp N/A Authorization Number N/A Expiration Date N/A Address :

Joseph M. Farley Nuclear Plant

4. Identification of System High Head Safety Injection / Chemical Volume Control System 5.

(a) Applicable Construction Code:

ASME Section 111.

19 71 Edition Summer 1971

Addenda, NIA Code Case (b) Applicable Section XI Utilized For Repairs Or Replacements 19 89 Edition NIA
Addenda, N/A Code Case
6. Identification of Components Repaired or Replaced and Replacement Components:

Name of Name of Manufacturer National Other Year

Repaired, ASME Component Manufacturer Serial Number Board Identification Built Replaced, or Code No.

Replacement Stamped (Yes /No)

Studs Unknown UNKNOWN N/A Piping System ID 1974 Replaced No Q-I-E21-CCB-3891 Nuts Unknown UNKNOWN N/A Piping System ID 1974

'Replaced No

._ _-l-E21-CCB-3891 Studs Mackson. Inc.

S20751 NIA FNP Purchase Order 2004 Replacement No I_

QP040263 Nuts Korea Bolt C91060 NIA FNP Purchase Order 2002 Replacement No QP040363

7. Description of Work During the performance of an ASME Section Xl pressure test. several of the bolts that retain flow orfice NIE21FE983 were determined to be affected by boron. All studs and nuts were replaced. Ref: Transaction Number 49644



8. Test Conducted El Hydrostatic F1 Pneumatic I]

Normal OperatingPressure 0

None D

Other Pressure PSI Temperature __

OF

Form NIS-2 Owner's Report for Repairs or Replacements As required by the provisions of the ASME Code Section XI RType: L1.52 Job Number E21 - 1040898001 ISheet 2 of 2

9. Remarks (Applicable Alanufacturer's Data Reports to be attached)

The specifications for original bolting was determined from review of SSI 109-2. The original CMTR's could not be found.

Heat Number for nuts is C91060 as listed. The Heat Code for nuts is JQB Certificate of Compliance We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xi.

repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization Number N/A Expiration Date N/A Signed Maintenance Manager Date

/4/

oy Owner or Owner's Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of e

and employed by Al 5J? - Cr of Ad^4er-t w torve have inspected the components described in this Owner's Report durinig the period 6Ad

,4 to

,/4/o S

, and state that to the best of my knowledge and belief, the Owner ha' performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions Ad 326

  • T"A lpsztor's Signature National Board, State, Province, and Endorsements Date

Form NIS-2 Owner's Report for Repairs or Replacements As required by the provisions of the ASME Code Section XI RType: L1S2 Job Number G24-1040905301 Sheet I of 2 I.

I w

I. Owner Southern Nuclear Operating Company 40 Inverness Center Parkway Birmingham, Alabama 35242 (as agent for Alabama Power Company)

2. Plant Farley Nuclear Plant Highway 95 South Columbia, Alabama 36319 Unit FNP 1 Date October 28, 2004
3. Work performed by Type Code Symbol Stamp N/A Name: Southern Nuclear Oneratine Companv Maintenance Department Authorization Number N/A Address:

Joseph M. Farley Nuclear Plant Expiration Date N/A

4. Identification of System I "C" Steam Generator Blow Down 5.

(a) Applicable Construction Code:

ASME Section III, 19 71 Edition Winter 1972

Addenda, NIA Code Case (b) Applicable Section XI Utilized For Repairs Or Replacements, 19 89 Edition N/A
Addenda, N/A Code Case
6. Identification of Components Repaired or Replaced and Replacement Components:

Name of Name of Manufacturer National Other Year

Repaired, ASME Component Manufacturer Serial Number Board Identification Built Replaced, or Code No.

Replacement Stamped (Yes / No)

Studs (2)

Texas Bolt Company RR43 N/A FNP Purchase Order 1973 Replaced No 7047-0-62015 Nuts (4)

Texas Bolt Company RR66 N/A FNP Purchase Order 1973 Replaced No

.____ =

7047-0-62015

=

=

Stud (2)

Texas Bolt Company 6096034 N/A FNP Purchase Order 1993 Replacement No QP040063 Nuts (2)

Texas Bolt Company 11399210 N/A FNP Purchase Order 2000 Replacement No

_P000530 Nuts (2)

Korea Bolt HT CODE -JQB N/A FNP Purchase Order 2002 Replacement No Companv HT. C91060 QP040363 I

b I

i1

7. Description or Work During the removal of the IC Steam Generator Blowdown Spoolpiece (Ref: OW71701401). 2 studs and 4 nuts were damaged. The damaged studs and nuts were replaced with new studs and nuts. (Ref: Transaction Numbers 49800 & 49698)



8. Test Conducted El Hydrostatic

[E Pneumatic El Normal Operating Pressure 3 None F1 Other Pressure PSI Temperature __

'IF 2-Z

Form NIS-2 Owner's Report for Repairs or Replacements As required by the provisions of the ASME Code Section XI RType: LI.52 Job Number G24 -

I 1040905301 Sheet 2 of 2 I.

w

9. Remarks (Applicable Manufacturer's Data Reports to be attached)

Certificate of Compliance We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl.

repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization Number N/A Expiration Date NIA Signed Maintenance Manager Date Al STrv'l Owner or Owner's Designee, Title Certificate of Inservice Inspection 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of De ad and employed by 15,13 - C7 of or-6 ecc 7 c CT have inspected the components described in this Owner's Report during the period to 5

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions 6-j 3 Z f; Z AM lzisp'ctor's Signature National Board, State. Province, and Endorsements Date

./

Form NIS-2 Owner's Report for Repairs or Replacements As required by the provisions of the ASME Code Section XI RType: L152 Job Number B21 - 104091060i Sheet I of 2 V

4

1. Owner Southern Nuclear Operating Company 40 Inverness Center Parkway Birmingham, Alabama 35242 (as agent for Alabama Power Company)
2. Plant Farley Nuclear Plant Highway 95 South Columbia, Alabama 36319 Unit FNP I Date October 27.2004
3. Work performed by Type Code Symbol Stamp N/A Name: Southern Nuclear Operating Company Maintenance Department Authorization Number N/A Address:

Joseph M. Farley Nuclear Plant Expiration Date N/A

4. Identification of System I"B Steam Generator 5.

(a) Applicable Construction Code:

ASME Section III, -

19 89 Edition NIA

Addenda, N/A Code Case (b) Applicable Section XI Utilized For Repairs Or Replacements, 19 89 Edition N/A
Addenda, N/A Code Case
6. Identification of Components Repaired or Replaced and Replacement Components:

Name of Component Name of Manufacturer Manufacturer Serial Number National Board No.

Other Identification Year Built

Repaired, Replaced, or Replacement ASME Code Stamped (Yes / No)

I Bolt Ionics 15 NIA FNP Purchase Order APA0At I R 2002 Replaced No Bolt Vicente Berrizbeitia 326 N/A FNP Purchase Order 199 Replacernent No O P70783

.I I

II 1

7. Description of Work While removing the hand hole covers on I B Steam Generator, the #6 bolt on the I OC cover was difficult to remove. The bolt had a damaged thread. The damaged bolt was replaced with a new bolt, along with a new washer. (Ref: Transaction Number 49959)

I.

8. Test Conducted r Hydrostatic

[

Pneumatic

] Normal Operating Pressure 3

None El Other Pressure PSI Temperature OF

Form NIS-2 Owner's Report for Repairs or Replacements As required by the provisions of the ASME Code Section M RType: L1.52 Job Number B21 -:

Sheet 1040910601 2 of 2 P.

W

9. Remarks (Applicable Manufacturer's Data Reports to be attached)

Certificate of Compliance We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xi.

repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization Number N/A Expiration Date N/A Signed a

7 6

r' Maintenance Manager Date Li /hL Lot Owner or Owner's Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of G

and employed by lv25-c7 of o

.'e p e

u 4.T>

have inspected the components described in this Owner's Report during the period A_ It p A

/a, to 1-3 Ad

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions

,-A ?Z a Mnspector's Signature National Board, State, Province, and Endorsements E Date I

Form NIS-2 Owner's Report for Repairs or Replacements As required by the provisions of the ASME Code Section XI RType: L1.52 Job Number B21 - 1041407501 Sheet 1 of 2 WEE_

1. Owner Southern Nuclear Operaiing Company 40 Inverness Center Parkway Birmingham, Alabama 35242 (as agent for Alabama Power Company)
2. Plant Farley Nuclear Plant Highway 95 South Columbia, Alabama 36319 Unit FNP I Date October 25, 2004
3. Work performed by Type Code Symbol Stamp N/A Name: Southern Nuclear Operatine Companv Maintenance Department Authorization Number N/A Address Joseph MI. Farley Nuclear Plant Expiration Date N/A
4. Identification of System I'"A" Steam Generator 5.

(a) Applicable Construction Code:

ASME Section III, 19 89 Edition N/A

Addenda, N/A Code Case (b) Applicable Section XI Utilized For Repairs Or Replacements, 19 89 Edition N/A
Addenda, N/A Code Case
6. Identification of Components Repaired or Replaced and Replacement Components:

Name of Name of Manufacturer National Other Year

Repaired, ASME Component Manufacturer Serial Number Board Identification Built Replaced, or Code No.

Replacement Stamped (Yes I No)

Bolt Vicente Berrizbeitia N/A FNP Purchase Order 1999 Replaced No Q_

_P970783 Bolt Vicente Berrizbeitia 30 N/A FNP Purchase Order 1999 Replaced No QP970783 Bolt Vicente Bcrrizbeitia 180 N/A FNP Purchase Order 1999 Replacement No QP970783 Bolt Vicente Bcrrizbeitia 198 N/A FNP Purchase Order 1999 Replacement No

_QP970783

7. Description of Work During the inspection of bolting prior to reinstallation of the #1DC hand hole cover on the IA Steam Generator (QIB21 H001A), it was discovered that two bolts were damaged. The damaged bolts were replaced with new bolts, along with new washers. Ref: Transaction Number 51535 w
8. Test Conducted E] Hydrostatic n

Pneumatic LI NormalOperatingPressure 3 None I]

Other Pressure PSI Temperature

`F

Form NIS-2 Owner's Report for Repairs or Replacements As required by the provisions of the ASME Code Section XI RType: L1.52 Job Number B21 -

I 1041407501 Sheet 2 of 2 h.

9. Remarks (Applicable Manufacturer's Data Reports to be attached)

Certificate of Compliance We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl.

repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization Number N/A Expiration Date N/A Signed 94Y4

_A Maintenance Manager Date L! ide Owner or Owner's Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of and employed by

,s*.r_- c r of zz~e u

-,-~es.

Jhave inspected the components described in this Owner's Report during the period s

to __

/-.>/=

,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions 1-Idspector's Signature National Board, State, Province, and Endorsements Date

Form NIS-2 Owner's Report for Repairs or Replacements As required by the provisions of the ASME Code Section XI RT~ype: L152 U

Job Number E21 - 20M0064801 Sheet I of 2 F.

i

1. Owner Southern Nuclear Operating Company 40 Inverness Center Parkway Birmingham, Alabama 35242 (as agent for Alabama Power Company)
2. Plant Farley Nuclear Plant Highway 95 South Columbia, Alabama 36319 Unit FNP I

Date November 12, 2004

3. Work performed by Type Code Symbol Stamp N/A Name: Southern Nuclear Operating Company Maintenance Department Authorization Number N/A Address:

Joseph M. Farley Nuclear Plant Expiration Date N/A

4. Identification of System Chemical Volume And Control System 5.

(a) Applicable Construction Code:

ASME Section ll, 19 86 Edition Summer 1986

Addenda, N/A Code Case (b) Applicable Section XI Utilized For Repairs Or Replacements, 19 89 Edition N/A
Addenda, N/A Code Case
6. Identification of Components Repaired or Replaced and Replacement Components:

Name of Name of Manufacturer National Other Year

Repaired, ASME Component Manufacturer Serial Number Board Identification Built Replaced, or Code No.

Replacement Stamped (Yes I No)

Seal Housing Pacific Pumps 2E299-AA N/A FNP Purchase Order 1989 Replaced No (Inboard)

QP3929 Seal Housing Pacific Pumps 2E299-AC N/A FNP Purchase Order 1989 Replaced No (Outboard)

_P3929 Seal Housing Flowserve RLSA01678-4 N/A QP040126 2001 Replacement No (Inboard)

Seal Housing Flowserve RLSA01678-5 N/A QP040126 2001 Replacement No (Outboard) i a

a a -

7. Description of Work The inboard and outboard seal housings were replaced on the lB Charging Pump (QIE21PO02B) as a pan of regularly scheduled maintenance.

Ref: Transaction Number 46381 w

8. Test Conducted El Hydrostatic M Pneumatic Z

Normal Operating Pressure I]

None 1=

Other Pressure PSI Temperature OF

Form NIS-2 Owner's Report for Repairs or Replacements As required by the provisions of the ASME Code Section Xl RType: L1.52 Job Number

.E21 -.

I Sheet 2 of 2 0M0064801



9. Remarks (Applicable Manufacturer's Data Reports to be attached)

Certificate of Compliance We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code,Section XI.

repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization Number N/A Expiration Date N/A Signed Maintenance Manager Date (W/L Le{b Owner or Owner's Designee. Title Certificate of Inservice Inspection 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State orProvinceof Game,-9 andemployedby ovS3-c T of

,'V

-e Er-o Cal ~cei c ecow have inspected the components described in this Owner's Report duringthe period

_/_________to

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions lnsior's Signature National Board, State, Province, and Endorsements Date

Form NIS-2 Owner's Report For Repairs Or Replacements As Required By The Provisions Of The ASME Code Section XI RType: L1.52 Job Number E2I-l M400346501 Sheet I of 2

-F Y

I Wil1. Owner Southern Nuclear Operating Company 40 Inverness Center Parkway Birmingham, Alabama 35242 (as agent for Alabama Power Company)

2. Plant Farley Nuclear Plant Highway 95 South Columbia, Al. 36319 Unit FNP I Date October 27. 2004
3. Work Performed By Type Code Symbol Stamp NIA Name: Southern Nuclear Operatine Company Maintenance Department Authorization Number N/A Address:

Joseph M. Farlev Nuclear Plant Expiration Date N/A

4.

Identification Of System Safety Injection System S.

(a) Applicable Construction Code:

  • Sec sheet 2, 19 Edition
Addenda, Code Case (b) Applicable Section XI Utilized For Repairs Or Replacements.

19 89 Edition N/A

Addenda, N/A Code Case
6. Identification Of Components Repaired Or Replaced and Replacement Components:

Name Of Name Of Manufacturer National Other Year Repaired ASMIE Component Manufacturer Serial Number Board Identification Built Replaced Or Code No.

Replacement Stamped

____(Yes

/ No)

Mech. Snubber Pacific Scientific 26126 N/A P.O. QPI301 1986 Replaced Yes Load Stud Pacific Scientific Unknown N/A P.O. FNP -222 1975 Replaced No Load Stud Nut Pacific Scientific Unknown N/A P.O. FNP - 22 1975 Replaced No Hyd. Snubber Lisega 03615870/ 117 NIA P.O. QP040545 2004 Replacement No Load Stud Grinnell Unknown N/A P.O. QP3129 1989 Replacement No Load Stud Nut Grinnell Unknown N/A P.O. QP3129 1989 Replacement No

7.

Description Of Work Snubber SS41975A was removed from its support by Williams Power Corporation, tested by Wyle Laboratories and was replaced with a Lisega hydraulic snubber by Williams Power Corporation as pan of a scheduled upgrade program. The load stud and load stud nuts damaged during snubber removal were replaced with approved equals. Ref: MIFs 49849, 50674

,w

8.

Test Conducted

[] Hydrostatic

] Pneumatic El Normal Operating Pressure

`

None n Other Pressure

_PSI Temperature _

OF

Form NIS-2 Owner's Report For Repairs Or Replacements As Required By The Provisions Of The ASME Code Section Xl RType: LI.52 Job Number E21 -M400346501 I Sheet 2 of 2 W

9.

Rermarks (Applicable Manufacturer's Data Reports To Be Attached)

  • Pipe hanger was designed to AISC 1969 ED. requirements and welded to AWS D 1.1-86 requirements using material traceability requirements of ASME Section Ill.

Certificate of Compliance We certify that the statements made in this report are correct and this ASME Code, Section Xl.

replacemnent conforms to the rules of the repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization Number N/A Expiration Date N/A Signed Date t/s IW/O Y Owner or Owner's Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of

?

and Employed by eSS

-= 7 of

,.have inspected the components described in this Owner's Report during the period

//,h4 to

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspecior nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

p

,4 Commissions GA 720 Inspctor's Signature National Board, State, Province, and Endorsements Date 0//E7

Form NIS-2 Owner's Report for Repairs or Replacements As required by the provisions of the ASME Code Section )I RType: L1.52 Job Number I

E21 - S400140601 Sheet I of 2 I

q S.

rWi1. Owner Southern Nuclear Operating Company 40 Inverness Center Parkway

2. Plant Farley Nuclear Plant Highway 95 South Columbia, Alabama 36319 Unit FNP I

Date October 21, 2004

3. Work performed by Type Code Symbol Stamp N/A Name: Southern Nuclear Oneratine Company Maintenance Department Authorization Number N/A Address Joseph M. Farley Nuclear Plant Expiration Date N/A
4. Identification of System Chemical Volume And Control System 5.

(a) Applicable Construction Code:

ASME Section 111.

19 71 Edition Summer 1971

Addenda, N/A Code Case (b) Applicable Section XI Utilized For Repairs Or Replacements, 19 89 Edition NIA Addenda,.

N/A Code Case

6. Identification of Components Repaired or Replaced and Replacement Components:

Name of Name of Manufacturer National Other Year

Repaired, ASME Component Manufacturer Serial Number Board Identification Built Replaced, or Code No.

Replacement Stamped (Yes I No)

Studs Texas Bolt Co.

HT37 N/A FNP Purchase Order 1980 Replaced No 7071-Q-60804.

Nuts Texas Bolt Co.

DV70 N/A FNP Purchase Order 1977 Replaced No 7071-0-60107 Studs Nova Machine 61184 N/A FNP Purchase Order 2001 Replacement No Products OPo 01382 Nuts Mackson Inc.

S44037 N/A FNP Purchase Order 2001 Replacement No.

=_______

0P010884

=

_=

7. Description or Work Inlet flange bolting on the Letdown Heat Exchanger (QIE21 H0004) was degraded. Eight studs and 16 nuts were replaced. Ref. Transaction Number 46867 W
8. Test Conducted M Hydrostatic El Pneumatic 2

Normal Operating Pressure 3 None El Other Pressure PSI Temperature OF

Form NIS-2 Owner's Report for Repairs or Replacements As required by the provisions of the ASME Code Section Xl RType: L1.52 Job Number E21 - S400140601

' Sheet 2 of 2

9. Remarks (Applicable Manufacturer's Data Reports to be attached)

Certificate of Compliance We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl.

repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization Number N/A Expiration Date N/A Signed Maintenance Manager Date IL/Z2./a '

Owner or Owner's Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ramp and employed by

,t.,r^ er of MA Ct 4

7°-

-r have inspected the components described in this Owner's Report dd'ring the period

-"I, to

/4/__

5_I

,and state that to the best of my knowledge and belief, the Owner has performed examinations and takencorrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in'this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

AsZ Commissions Ky-A YZE G

'Inspector's Signature National Board, State, Province, and Endorsements Date

.4

{ __

Form NIS-2 Owner's Report For Repairs Or Replacements As Required By The Provisions Of The ASME C6de Section Xl RType: L1.52 Job Number E21 - S400347101 Sheet I of 2

'UI 4

WI

1. Owner Southern Nuclear Operating Company 40 Inverness Center Parkway Birmingham, Alabama 35242 (as agent for Alabama Power Company)
2. Plant Farley Nuclear Plant Highway 95 South Columbia, Al. 36319 Unit FNP I Date October 27, 2004
3. Work Performed By Type Code Symbol Stamp N/A Name: Southern Nuclear Operatine Comnan~ Maintenance Department Authorization Number N/A Address:

Joseph M. Farlev Nuclear Plant Expiration Date N/A

4. Identification Of System Safety Injection System 5.

(a) Applicable Construction Code:

  • See sheet 2 19 Edition'
Addenda, Code Case (b) Applicable Section XI Utilized For Repairs Or Replacements, 19 89 Edition N/A
Addenda, N/A Code Case
6. Identification Of Components Repaired Or Replaced and Replacement Components:

Name Of Name Of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial Number Board Identification Built Replaced Or Code No.

Replacement Stamped

, (Yes / No)

Mech. Snubber Pacific Scientific 38342 N/A P.O. QP2244 1988 Replaced No Hyd. Snubber Usega 03615870/ 133 N/A P.O. QP040545 2004 Replacement No

7.

Description Of Work Snubber SS-1975C was removed from its support by Williams Power Corporation, tested by Wyle Laboratories and was replaced with a Lisega hydraulic snubber by Williams Power Corporation as part of a scheduled upgrade program. Ref: MIF 49858

-I.

8.

Test Conducted E

Hydrostatic El Pneumatic [E Normal Operating Pressure [3 None [1 Other Pressure PSI Temperature OF

Form NIS-2 Owner's Report For Repairs Or Replacements tType: L1.52 As Required By The Provisions Of The ASME Code Section Xl Job Number E21-S400347101 Sheet 2 of 2

9.

Remarks (Applicable Manufacturer's Data Reports To Be Attached)

  • Pipe hanger was designed to AISC 1969 ED. requirements and welded to AWS D 1.1-86 requirements using material traceability requirements of ASME Section III.

Certificate of Compliance We certify that the statements made in this report are correct and this replacement conforms to the rules of the ASME Code, Section Xl.

repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization Number NIA Expiration Date N/A Signed Date it/#

5

/0y Owner or Owner's Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of and Employed by AsP-7r of C

have inspected the components described in this Owner's Report during the period

,0,

/

1y 7

to A/ --

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI; By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions Z

G

--hnsf ector's Signature National Board, State, Province, and Endorsements Date

Form NIS-2 Owner's Report For Repairs Or Replacements As Required By The Provisions Of The ASME C6de Section Xl RType: L1.52 Job Number E21 -S400347201 Sheet I of 2 h

U U

w

1. Owner Southern Nuclear Operating Company 40 Inverness Center Parkway Birmingham, Alabama 35242 (as agent for Alabama Power Company)
2. Plant Farley Nuclear Plant Highway 95 South Columbia, Al. 36319 Unit FNP I Date October 27.2004
3. Work Performed By Type Code Symbol Stamp NIA Name: Southern Nuclear Operating Company Maintenance Department Authorization Number N/A Address:

Joseph M. Farlev Nuclear Plant Expiration Date N/A

4. Identification Of System Safety Injection System 5.

(a) Applicable Construction Code:

  • See sheet 2, 19 Edition Addenda.

Code Case (b) Applicable Section XI Utilized For Repairs Or Replacements, 19 89 Edition N/A

Addenda, N/A Code Case
6. Identification Of Components Repaired Or Replaced and Replacement Components:

Name Of Name Of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial Number Board Identification Built Replaced Or Code No.

Replacement Stamped

_ _ _(

Y e s I N o )

Mech. Snubber Pacific Scientific 26135 NIA P.O. QPI301 1986 Replaced Yes Load Stud Pacific Scientific Unknown N/A P.O. FNP -222 1975 Replaced No Load Stud Nut Pacific Scientific Unknown N/A P.O. FNP -222 1975 Replaced No Hyd. Snubber Usega 03615730/ 132 N/A P.O. QP030735 2003 Replacement No Load Stud Grinnell Unknown N/A P.O. QP3129 1989 Replacement No Load Stud Nut Grinnell Unknown N/A P.O. QP3129 1989 Replacement No

7.

Description Of Work Snubber SS-1975F was removed from its support by Williams Power Corporation, tested by Wyle Laboratories and was replaced with a Lisega hydraulic snubber by Williams Power Corporation as part of a scheduled upgrade program. The load stud and load stud nuts damaged during snubber removal were replaced with approved equals. Ref: MIF 45861, 50676

8.

Test Conducted Hydrostatic a

Pneumatic [D NormalOperatingPressure 3

None n Other Pressure PSI Temperature OF

Form NIS-2 Owner's Report For Repairs Or Replacements As Required By The Provisions Of The ASME Code Section XI RType: L1S2 Job Number E21 - S400347201 I Sheet 2

of 2 W

l 9.

Remarks (Applicable Manufacturer's Data Reports To Be Attached)

  • Pipe hanger was designed to AISC 1969 ED. requirements and welded to AWS D 1.1-86 requirements using material traceability requirements of ASME Section Ill.

Certificate of Compliance We certify that the statements made in this report are correct and this ASME Code, Section Xl.

replacement repair or replacement conforms to the rules of the Type Code Symbol Stamp N/A Certificate of Authorization Number Signed

/T N/A Expiration Date N/A Date 4 He it /° Y Owner or Owner's Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of C

and Employed by wUSA-er of A 7r have inspected the components described in this Owner's Report during the period v

to _

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions Gun SZS Isp tor's Signature National Board, State, Province, and Endorsements Date

Form NIS-2 Owner's Report For Repairs Or Replacements As Required By The Provisions Of The ASME Code Section XI RType: LI.52 Job Number E21 -' 5400347301 Sheet I of 2

1. Owner
2. Plant Unit Southern Nuclear Operating Company Farley Nuclear Plant 40 Inverness Center Parkway Highway 95 South FNP I Birmingham, Alabama 35242 Columbia, Al. 36319 Date (as agent for Alabama Power Company)

October 26, 2004

3. Work Performed By Type Code Symbol Stamp N/A Name: Southern Nuclear Oneratins Companv Maintenance Department Authorization Number N/A Address:

Joseph M. Farlev Nuclear Plant Expiration Date N/A

4.

Identification Of System Safety Injection System 5.

(a) Applicable Construction Code:

  • See sheet 2, 19 Edition
Addenda, Code Case (b) Applicable Section Xi Utilized For Repairs Or Replacements, 19 89 Edition N/A Addenda.

N/A Code Case

6. Identification Of Components Repaired Or Replaced and Replacement Components:

Name Of Name Of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial Number Board Identification Built Replaced Or Code No.

Replacement Stamped

_ _ _(Y es / N o)

Mech. Snubber Pacific Scientific 14068 N/A P.O. QP1299 1980 Replaced Yes Hyd. Snubber Lisega 036158701092 N/A P.O. QP040545 2004 Replacement No

7.

Description Of Work Snubber SS-1975G was removed from its support by Williams Power Corporation, tested by Wyle Laboratories and was replaced with a Lisega hydraulic snubber by Williams Power Corporation as part of a scheduled upgrade program. Ref: MIF 45859

8.

Test Conducted

[

Hydrostatic l Pneumatic []

Normal Operating Pressure 3 None E:

Other Pressure PSI Temperature

`F

Form NIS-2 Owner's Report For Repairs Or Replacements As Required By The Provisions Of The ASME Code Section X1 RType: L1.52 Job Number E21 - S400347301 I Sheet 2 of 2

- w

9.

Remarks (Applicable Manufacturer's Data Reports To Be Attached)

  • Pipe hanger was designed to AISC 1969 ED. requirements and welded to AWS D 1.1-86 requirements using material traceability requirements of ASME Section 111.

Certificate of Compliance We certify that the statements made in this report are correct and this ASME Code, Section Xl.

replacement repair or replacement conforms to the rules of the Type Code Symbol Stamp N/A Certificate of Authorization Number N/A Expiration Date N/A Signed Date ll&YI/Dy Owner or Owner's Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of _

and Employed by ASa-c-r of 4

C1 have inspected the components described in this Owner's Report during the period

?

to

__a/

,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions 6-3 ZA 4

nsector's Signature National Board, State, Province, and Endorsements Date.

Form NIS-2 Owner's Report For Repairs Or Replacements As Required By The Provisions Of The ASME Code Section Xl RType: L1.52 U

Job Number I

E21 -S400347701 Sheet I of 2

1. Owner
2. Plant Unit Southern Nuclear Operating Company Farley Nuclear Plant 40 Inverness Center Parkway Highway 95 South FNP I Birmingham, Alabama 35242 Columbia, Al. 36319 Date (as agent for Alabama Power Company)

October 18. 2004

3. Work Performed By Type Code Symbol Stamp N/A Name: Southern Nuclear Operating Company Maintenance Department Authorization Number N/A Address:

Joseph NIt. Farlev Nuclear Plant Expiration Date N/A

4. Identification Of System Chemical and Volume Control System 5.

(a) Applicable Construction Code:

  • See sheet 2, 19 Edition
Addenda, Code Case (b) Applicable Section XI Utilized For Repairs Or Replacements, 19 89 Edition N/A Addenda.

N/A Code Case

6. Identification Of Components Repaired Or Replaced and Replacement Components:

Name Of Name or Manufacturer National Other Year Repaired ASME Component Manufacturer Serial Number Board Identification Built Replaced Or Code No.

Replacement Stamped

_ _ _(Y es / N o)

Mech. Snubber Pacific Scientific 34184 N/A P.O. QP1299 1983 Replaced No Hyd. Snubber Lsega 03615730/051 N/A P.O. QP040545 2004 Replacement No

7.

Description Of Work Snubber SS-2743 was removed from its support by Williams Power Corporation. tested by Wyle Laboratories and was replaced with a Lisega hydraulic snubber by Williams Power Corporation as part of a scheduled upgrade program. Ref: MIF 45854

8.

Test Conducted

[.

Hydrostatic Pneumatic F1 Normal]OperatingPressure 13 None []

Other Pressure PSI Temperature OF

Form NIS-2 Owner's Report For Repairs Or Replacements RType: Ll-52 As Required By The Provisions Of The ASME Code Section Xl Job Number E21 - S400347701 Sheet 2 of 2

9. Remarks (Applicable Manufacturer's Data Reports To Be Attached)
  • Pipe hanger was designed to AISC 1969 ED. requirements and welded to AWS D 1. 1-86 requirements using material traceability requirements of ASME Section 111.

Certificate of Compliance We certify that the statements made in this report are correct and this replacement conforms to the rules of the ASME Code, Section Xl.

repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization Number N/A Expiration Date N/A Signed

?

6 Date

__ot Owner or Owner's Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of _

_1__

and Employed by 4SE-co of AmA Amco, Car have inspected the components described in this Owner's Report during the period A,/jj/

4' to

,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken' corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

,Commissions Te ZS hThpctor's Signature National Board, State, Province, and Endorsements Date A/A/1aY

Form NIS-2 Owner's Report For Repairs Or Replacements As Required By The Provisions Of The ASME Code Section XI RType: L1.52 Job Number G24 - S400348101 Sheet I of 2 I.

M 1.

Owner Southern Nuclear Operating Company 40 Inverness Center Parkway Birmingham, Alabama 35242 (as agent for Alabama Power Company)

2.

Plant Unit Farley Nuclear Plant Highway 95 South Columbia, Al. 36319 FNP I Date October 21, 2004

3. Work Perforned By Type Code Symbol Stamp

. A Name: Southern Nuclear Operatine Company Maintenance Department Authorization Number N/A Address:

Joseph M. Farlev Nuclear Plant Expiration Date NIA

4. Identification Of System Steam Generator Blowdown Treatment System 5.

(a) Applicable Construction Code:

  • See sheet 2, 19 Edition
Addenda, Code Case (b) Applicable Section Xi Utilized For Repairs Or Replacements, 19 89 Edition N/A
Addenda, N/A Code Case
6. Identification Of Components Repaired Or Replaced and Replacement Components:

Name Of Name Of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial Number Board Identification Built Replaced Or Code No.

Replacement Stamped (Y es I N o)

Mech. Snubber Pacific Scientific 26153 N/A P.O. QP1301 1986 Replaced Yes Hyd. Snubber Usega 03615870/171 N/A P.O. QP040545 2004 Replacement No

7.

Description Of Work Snubber SS-4462 was removed from its support by Williams Power Corporation, tested by Wyle Laboratories and was replaced with a Lisega hydraulic snubber by Williams Power Corporation as part of a scheduled upgrade program. Ref: MIF 45845

8.

Test Conducted W Hydrostatic M Pneumatic [

NormalOperatingPressure Z None []

Other Pressure PSI Temperature OF

Form NIS-2 Owner's Report For Repairs Or Replacements As Required By The Provisions Of The ASME Code Section XI RType: L1.52 Job Number G24 - S400348 101 I Sheet 2 of 2

9.

Remarks (Applicable Manufacturer's Data Reports To Be Attached)

  • Pipe hanger was designed to AISC 1969 ED. requirements and welded to AWS D 1.1-86 requirements using material traceability requirements of ASME Section 111.

Certificate of Compliance We certify that the statements made in this report are correct and this ASME Code,Section XI.

replacement repair or replacement conforms to the rules of the Type Code Symbol Stamp N/A Certificate of Authorization Number N/A Expiration Date N/A Signed Owner or Owner's Designee, Title Date tLq o't/° e

Certificate of Inservice Inspection I, the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of _

and Employed by A4s7-er of A'd C.i-.,ceQ ehave inspected the components described in this Owner's Report during the period jJ/1.^ 0.Y' to

,/i4,'

,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions boo :Z US6A

-ir sector's Signature National Board, State, Province, and Endorsements Date

/5>/o Z

Form NIS-2 Owner's Report For Repairs Or Replacements As Required By The Provisions Of The ASME Code Section )a RType: L1.52 1*

Job Number G24 - S400348401 Sheet I of 2 1.

Owner

2.

Plant Unit Southern Nuclear Operating Company Farley Nuclear Plant 40 Inverness Center Parkway Highway 95 South FNP I Birmingham, Alabama 35242 Columbia, Al. 36319 Date (as agent for Alabama Power Company)

October 18. 2004

3. Work Performed By Type Code Symbol Stamp N/A Name : Southern Nuclear Oneratine Company Maintenance Department Authorization Number N/A Address:

Joseph M. Farlev Nuclear Plant Expiration Date N/A

4.

Identification Of System Steam Generator Blowdown Treatment System 5.

(a) Applicable Construction Code:

  • See sheet 2.

19 Edition

Addenda, Code Case (b) ApplicableSectionXI Utilized ForRepairsOrReplacements, 19 89 Edition N/A Addenda.

N/A Code Case

6. Identification Of Components Repaired Or Replaced and Replacement Components:

Name or Name Of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial Number Board Identification Built Replaced Or Code No.

Replacement Stamped

( Yes I N o )

Mech. Snubber Pacific Scientific 14131 N/A P.O. QP1299 1982 Replaced Yes Load Stud Pacific Scientific Unknown N/A P.O. FNP -222 1976 Replaced No Load Stud Nut Pacific Scientific Unknown N/A P.O. FNP - 222 1976 Replaced No Hyd. Snubber I

.Usega 03615870/097 N/A P.O. QP040545 2004 Replacement No Load Stud Grinnell Unknown N/A P.O. QP3129 2004 Replacement No Load Stud Nut Grinnell Unknown N/A P.O. QP3129 2004 Replacement No

7.

Description Of Work Snubber SS-4576B was removed from its support by Williams Power Corporation, tested by Wyle Laboratories and was replaced with a Lisega hydraulic snubber by Williams Power Corporation as part of a scheduled upgrade program. The load stud and nuts damaged during snubber removal were replaced with approved equals. Ref: MlFs 45809,49554

8.

Test Conducted-W Hydrostatic a

Pneumatic n Normal Operating Pressure 3 None FI Other Pressure PSI Temperature OF

Form NIS-2 Owner's Report For Repairs Or Replacements RType: L1-52 As Required By The Provisions Of The ASME Code Section Xl Job Number G24 - S400348401 Sheet 2 of 2

9.

Remarks (Applicable Manufacturer's Data Reports To Be Attached)

  • Pipe hanger was designed to AISC 1969 ED. requirements and welded to AWS D 1.1-86 requirements using material traceability requirements of ASME Section III.

Certificate of Compliance We certify that the statements made in this report are correct and this replacement conforms to the rules of the ASME Code,Section XI.

repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization Number N/A Expiration Date N/A Signed Date 0l l/°

./

Owner or Owner's Designee. Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of G

e.,

and Employed by.

cs- - cr7 of A4W&r -

c

-r have inspected the components described in this Owner's Report during the period

)p/g to

,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

{

Commissions ur-. 3 Ipspctor's Signature National Board, State, Province, and Endorsements Date

Form NIS-2 Owner's Report For Repairs Or Replacements As Required By The Provisions Of The ASME Code Section Xl RType: L1.52 Job Number G24 - S400348501 Sheet I of 2

1. Owner
2. Plant Unit Southern Nuclear Operating Company Farley Nuclear Plant 40 Inverness Center Parkway Highway 95 South FNP 1 Birmingham, Alabama 35242 Columbia, Al. 36319 Date (as agent for Alabama Power Company)

October 26. 2004

3. Work Performed By Type Code Symbol Stamp N/A Name: Southern Nuclear Oneratine Companv Maintenance Department Authorization Number N/A Address:

Joseph M. Farlev Nuclear Plant Expiration Date N/A

4.

Identification Of System Steam Generator Blowdown Treatment System 5.

(a) Applicable Construction Code:

  • See sheet 2,

19 Edition

Addenda, Code Case (b) Applicable Section XI Utilized For Repairs Or Replacements, 19 89 Edition N/A Addenda.

N/A Code Case

6. Identification Of Components Repaired Or Replaced and Replacement Components:

Name Of Name Of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial Number Board Identification Built Replaced Or Code No.

Replacement Stamped

___________(Yes I No)

Mech. Snubber Pacific Scientific 24089 N/A P.O. QP1470 1987 Replaced No Load Stud Pacific Scientific Unknown NIA P.O. QPS308 1990 Replaced No Load Stud Nut Pacific Scientific Unknown N/A P.O. QP6915 1992 Replaced No Hyd. Snubber Lisega 03615960/064 N/A P.O. QP040462 2004 Replacement No Load Stud Pacific Scientific N2360E N/A P.O. QP0896 1986 Replacement No Load Stud Nut Grinnell Unknown N/A P.O. QP3129 1989 Replacement No

7.

Description Of Work Snubber SS-458 IA was removed from its support by Williams Power Corporation, tested by Wyle Laboratories and was replaced with a Lisega hydraulic snubber by Williams Power Corporation as part of a scheduled upgrade program. The load stud and nuts damaged during snubber removal were replaced with approved equals. Ref: MIFs 45862,49855

8.

Test Conducted L Hydrostatic E Pneumatic E Normal Operating Pressure 3

None D Other Pressure PSI Temperature OF

Form NIS-2 Owner's Report For Repairs Or Replacements As Required By The Provisions Of The ASME Code Section XI RType: L1S2 Job Number I

G24 -S400348501 Sheet 2 of 2

9.

Remarks (Applicable Manufacturer's Data Reports To Be Attached)

  • Pipe hanger was designed to AISC 1969 ED. requirements and welded to AWS D 1.1-86 requirements using material traceability requirements of ASME Section 111.

Certificate of Compliance We certify that the statements made in this report are correct and this replacement conforms to the rules of the ASME Code,Section XI.

repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization Number N/A Expiration Date N/A Signed Date 111_4_V_

Owner or Owner's Designee, Title Certificate of Inservice Inspection

1. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of _

and Employed by

-aes-7r of DAY Fe. ^

r have inspected the components described in this Owner's Report during thd'period

&ZA/jh,0 to

'///='

t

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

sp-ector's4pia.ure Commissions GA 7Z 1-iiector's Signature National Board, State, Province, and Endorsements Date.

//__

le _

I Form NIS-2 Owner's Report For Repairs Or Replacements As Required By The Provisions Of The ASME Code Section XI RType: L1.52 U

Job Number I

G24 - S400348601 I

t

1. Owner Southern Nuclear Operating Company 40 Inverness Center Parkway Birmingham, Alabama 35242 (as agent for Alabama Power Company)
2. Plant Farley Nuclear Plant Highway 95 South Columbia, Al. 36319 Sheet I of 2 Unit FNP I Date October 27. 2004
3. Work Performed By Type Code Symbol Stamp N. A Name: Southern Nuclear Operatine Companv Mfaintenance Department Authorization Number N/A Address:

Joseph M. Farlev Nuclear Plant ion Date N/A

4.

Identification Of System Steam Generator Blowdown Treatment System

5.

(a) Applicable Construction Code:

  • See sheet 2, 19 Edition
Addenda, Code Case (b) Applicable Section XI Utilized For Repairs Or Replacements, 19 89 Edition N/A
Addenda, N/A Code Case
6. Identification Of Components Repaired Or Replaced and Replacement Components:

Name Of Name Of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial Number Board Identification Built Replaced Or Code No.

Replacement Stamped (Yes / No)

Mech. Snubber Pacific Scientific 506 N/A P.O. FNP -222 1976 Replaced No Load Stud Pacific Scientific Unknown N/A P.O. FNP -222 1976 Replaced No Load Stud Nut Pacific Scientific Unknown N/A P.O. FNP -222 1976 Replaced No Hyd. Snubber Usega 03615960/065 N/A P.O. QP040462 2004 Replacement No Load Stud Pacific Scientific Unknown N/A P.O. QP1536 1988 Replacement No Load Stud Nut Grinnell Unknown N/A P.O. QP3129 1989 Replacement No

7.

Description Of Work Snubber SS-4581D was removed from its support by Williams Power Corporation, tested by Wyle Laboratories and was replaced with a Lisega hydraulic snubber by Williams Power Corporation as part of a scheduled upgrade program. The load stud and nuts damaged during snubber removal were replaced with approved equals. Ref: MIFs 45864, 49852

8.

Test Conducted M

Hydrostatic

[1 Pneumatic 2

Normal Operating Pressure 3

None I]

Other Pressure PSI Temperature _

OF z

  • Form NIS-2 Owner's Report For Repairs Or Replacements RType: L1.52 As Required By The Provisions Of The ASME Code Section Xl Job Number l

I G24 - S400348601 l Sheet 2 of 2

9.

Remarks (Applicable Manuracturer's Data Reports To Be Attached)

  • Pipe hanger was designed to AISC 1969 ED. requirements and welded to AWS D 1.1-86 requirements using material traceability requirements of ASME Section 111.

Certificate of Compliance We certify that the statements made in this report are correct and this replacement conforms to the rules of the ASME Code, Section Xl.

repair or replacement Type Code Symbol Stamp NIA Certificate of Authorization Number N/A Expiration Date N/A Signed Date Owner or Owner's Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of and Employed by

____S

_____-___7__

of

/Cor 6

CTI have inspected the components described in this Owner's Report durinig the period q,/o/6 to

'/L, a

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described.in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions 6:.,

  • Z s XAg h4 kiS~ctor's Signature National Board, State, Province, and Endorsements Date 11/1/v

Form NIS-2 Owner's Report For Repairs Or Replacements As Required By The Provisions Of The ASME Code Section Xl RType: L1.52 Job Number G24 - S400348701 Sheet I of 2

-3 WI1.

Owner Southern Nuclear Operating Company 40 Inverness Center Parkway Birningham, Alabama 35242 (as agent for Alabama Power Company)

2. Plant Farley Nuclear Plant Highway 95 South Columbia, Al. 36319 Unit FNP I Date October 21, 2004
3. Work Performed By Type Code Symbol Stamp NIA Name: Southern Nuclear Oneratini Companv Maintenance Department Authorization Number N/A Address:

Joseph M. Farley Nuclear Plant Expiration Date N/A

4. Identification Of System Steam Generator Blowdown Treatment System S.

(a) Applicable Construction Code:

  • See sheet 2, 19 Edition Addenda.

Code Case (b) Applicable Section XI Utilized For Repairs Or Replacements, 19 89 Edition N/A

Addenda, N/A Code Case
6. Identification Of Components Repaired Or Replaced and Replacement Components:

Name or Name Of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial Number Board Identification Built Replaced Or Cod No.

Replacement (Yestmpeod Mech. Snubber Pacific Scientific 3502 N/A P.O. FNP 2-29 1977 Replaced Yes Hyd. Snubber Lisega 0f615120/082 N/A P.O. QP040462 2004 Replacement No

7.

Description Of Work Snubber SS-4587A was removed from its support by Williams Power Corporation. tested by Wyle Laboratories and was replaced with a Lisega hydraulic snubber by Williams Power Corporation as part of a scheduled upgrade program. Ref: MIF 47327

8.

Test Conducted F

Hydrostatic El Pneumatic DI Normal Operating Pressure Z None E1 Other Pressure PSI Temperature F_

F

Form NIS-2 Owner's Report For Repairs Or Replacements As Required By The Provisions Of The ASME Code Section XI RType: L1.52 Job Number G24 - S400348701 I Sheet 2 of 2

--w

9.

Remarks (Applicable Manufacturer's Data Reports To Be Attached)

  • Pipe hanger was designed to AISC 1969 ED. requirements and welded to AWS D 1.1-86 requirements using material traceability requirements of ASME Section 111.

Certificate of Compliance We certify that the statements made in this report are correct and this replacement conforms to the rules of the ASME Code.Section XI.

repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization Number N/A Expiration Date N/A Signed Date

-LtOdoX Owner or Owner's Designee. Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of G

and Employed by NrsS-CT of He.47'7o C 7 have inspected the components described in this Owner's Report during the period to

,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

_ Commissions 4

lnructor's Signature National Board, State, Province, and Endorsements Date

/

V S-

Form NIS-2 Owner's Report For Repairs Or Replacements As Required By The Provisions Of The ASME Code Section XI RType: L1.52 Job Number E21. S400349001 Sheet I of 2 b

1.

Owner Southern Nuclear Operating Company 40 Inverness Center Parkway Birmingham, Alabama 35242 (as agent for Alabama Power Company)

2. Plant Farley Nuclear Plant Highway 95 South Columbia, Al. 36319 Unit FNP I Date October 18, 2004
3. Work Performed By Type Code Symbol Stamp N/A Name: Southern Nuclear Oeratine Company Maintenance Department Authorization Number N/A Address:

Joseph M. Farlev Nuclear Plant Expiration Date N/A

4. Identification Of System Chemical and Volume Control System S.

(a) Applicable Construction Code:

See sheet 2, 19 Edition

Addenda, Code Case (b) Applicable Section XI Utilized For Repairs Or Replacements, 19 89 Edition N/A
Addenda, N/A Code Case
6. Identification Of Components Repaired Or Replaced and Replacement Components:

Name Of Name Of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial Number Board Identification Built Replaced Or Code No.

Replacement Stamped (Y es / N o)

Mech. Snubber Pacific Scientific 2524 N/A P.O. FNP 2-29 1978 Replaced Yes Hyd. Snubber Lisega 03615870/170 N/A P.O. QP040545 2004 Replacement No

7.

Description Of Work Snubber SS-6459 was removed from its support by Williams Power Corporation. tested by Wyle Laboratories and was replaced with a Lisega hydraulic snubber by Williams Power Corporation as part of a scheduled upgrade program. Ref: MIF 45806

8.

Test Conducted

[3 Hydrostatic E] Pneumatic NormalOperating Pressure None Other Pressure PSI Temperature OF

Form NIS-2 Owner's Report For Repairs Or Replacements As Required By The Provisions Of The ASME Code Section XI RType: L1.52 Job Number E21 -'

I Sheet 2 S400349001 of 2

9.

Remarks (Applicable Manufacturer's Data Reports To Be Attached)

  • Pipe hanger was designed to AISC 1969 ED. requirements and welded to AWS D 1.1-86 requirements using material traceability requirements of ASME Section Ill.

Certificate of Compliance We certify that the statements made in this report are correct and this ASME Code.Section XI.

replacement conforms to the rules of the repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization Number Signed N/A Expiration Date N/A Date ub,,(

I 61 Owner or Owner's Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of CODA and Employed by W Sr1 - c7-of

.eciMott eCT' have inspected the components described in this Owner's Report during the period A,/

/, a to

, '/,k /

,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

J Commissions 6-, 5 AJAVA lnr5ector's Signature National Board, State, Province, and Endorsements Date

,I////o

Form NIS-2 Owner's Report For Repairs Or Replacements As Required By The Provisions Of The ASME Code Section X1 RType: L1I2 Job Number E21 - S400349101 Sheet I of 2 I.

1.

Owner Southern Nuclear Operating Company 40 Inverness Center Parkway Birmingham, Alabama 35242 (as agent for Alabama Power Company)

2.

Plant

  • Farley Nuclear Plant Highway 95 South Columbia, Al. 36319 Unit FNP I Date October 27 2004
3. Work Performed By Type Code Symbol Stamp N/A Name: Southern Nuclear Onerating Companv M1aintenance Department Authorization Number N/A Address:

Joseph M. Farlev Nuclear Plant Expiration Date N/A

4.

Identification Of System Chemical and Volume Control System 5.

(a) Applicable Construction Code:

See sheet 2 19 Edition

Addenda, Code Case (b) Applicable Section XI Utilized ForRepairsOrReplacements, 19 89 Edition N/A Addenda.

N/A Code Case

6. Identification Of Components Repaired Or Replaced and Replacement Components:

Name or Component Name Of Manufacturer Manufacturer Serial Number National Board No.

Other Identification Year Built Repaired Replaced Or Replacement ASME Code Stamped (Yp / No)W Mech. Snubber Pacific Scientific 2477 N/A P.O. FNP 2-29 1978 Replaced Yes Hyd. Snubber Usega 03615870/ 172 N/A P.O. QP040545 2004 Replacement No

7.

Description Of Work Snubber SS-6460 was removed from its support by Williams Power Corporation, tested by Wyle Laboratories and was replaced with a Lisega hydraulic snubber by Williams Power Corporation as part of a scheduled upgrade program. Ref: MIF 45805

8.

Test Conducted LI Hydrostatic

-1 Pneumatic I]

NormalOperatingPressure 3

None LI Other Pressure PSI Temperature OF Z

Form NIS-2 Owner's Report For Repairs Or Replacements As Required By The Provisions Of The ASME Code Section XI RType: L1.52 Job Number E21.

ISheet S400349101 2 of 2

9.

Remarks (Applicable Manufacturer's Data Reports To Be Attached)

  • Pipe hanger was designed to AISC 1969 ED. requirements and welded to AWS D 1.1-86 requirements using material traceability requirements of ASME Section III.

Certificate of Compliance We certify that the statements made in this report are correct and this replacement conforms to the rules of the ASME Code,Section XI.

repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization Number N/A Expiration Date N/A Signed

/

Z Date it/

a/O4 Owner or Owner's Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of G

and Employed by Af ae.- c7T of

,Asc7IC 0t Or have inspected the components described in this Owner's Report during the period to _

_/_,__--__/

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions 4A SZ*

_A1

-t'spector's Signature National Board, State, Province, and Endorsements Date

Form NIS-2 Owner's Report For Repairs Or Replacements As Required By The Provisions Of The ASME Code Section Xl RType: L1.52 w

Job Number E21 -'S400351901 Sheet I of 2

1. Owner
2. Plant Unit Southern Nuclear Operating Company Farley Nuclear Plant 40 Inverness Center Parkway Highway 95 South FNP I Birmingham, Alabama 35242 Columbia, Al. 36319 Date (as agent for Alabama Power Company)

October 27.2004

3. Work Performed By Type Code Symbol Stamp N/A Name: Southern Nuclear Oneratine Companv Maintenance Department Authorization Number N/A Address:

Joseph M. Farlev Nuclear Plant Expiration Date N/A

4. Identification Of System Chemical and Volume Control System 5.

(a) Applicable Construction Code:

  • See sheet 2, 19 Edition Addenda.

Code Case (b) Applicable Section XI Utilized For Repairs Or Replacements, 19 89 Edition N/A Addenda.

N/A Code Case

6. Identification Of Components Repaired Or Replaced and Replacement Components:

Name Of Component Name Of Manufacturer Manufacturer Serial Number National Board No.

Other Identification Year Built Repaired Replaced Or Replacement ASME Code Stamped (Yes / No)

Load Stud Grinnell Unknown N/A P.O. FNP-222 1976 Replaced No Load Stud Nut Grinnell Unknown N/A P.O. FNP-222 1976 Replaced No Load Stud Grinnell 13A N/A P.O. QP1547 1987 Replacement No Load Stud Nut Grinnell MPI N/A P.O. QP5677 1991 Replacement No

7.

Description Of Work Snubber CVCS-R504 was removed from its support by Williams Power Corporation. tested by Wyle Laboratories and was reinstalled by Williams Power Corporation. The load stud and load stud nuts damaged during snubber removal were replaced with approved equals.

Ref: MIF 50741

8.

Test Conducted R

Hydrostatic E1 Pneumatic D Normal Operating Pressure 3 None El Other Pressure PSI Temperature OF

Form NIS-2 Owner's Report For Repairs Or Replacements RType: L1.52 As Required By The Provisions Of The ASME Code Section XI Job Number 2

E21 - S400351901 lSheet 2 of 2

9.

Remarks (Applicable Manufacturer's Data Reports To Be Attached)

  • Pipe hanger was designed to AISC 1969 ED. requirements and welded to AWS D 1.1-86 requirements using material traceability requirements of ASME Section 111.

Certificate of Compliance We certify that the statements made in this report are correct and this replacement conforms to the rules of the ASME Code,Section XI.

repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization Number N/A Expiration Date N/A Signed Date id_

_e Owner or Owner's Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of and Employed by vs

-c7 of jV

=Cr have inspected the components described in this Owner's Report during the period

/_ _

to e/94 o

y

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

hi_

pCommissions Go 13 tor's Signature National Board, State, Province, and Endorsements Date 11191ic4

Form NIS-2 Owner's Report For Repairs Or Replacements As Required By The Provisions Of The ASME Code Section XI RType: L1.52 I

E21 -S400356101 ri Wl

1. Owner Southern Nuclear Operating Company 40 Inverness Center Parkway Birmingham, Alabama 35242 (as agent for Alabama Power Company)
2. Plant Farley Nuclear Plant Highway 95 South Columbia, Al. 36319 Y

3.

Work Performed By Name: Southern Nuclear Operating Company Maintenance Department Type Code Symbol Stamp N/A Authorization Number N/A Address:

Joseph M. Farlev Nuclear Plant Expiration Date N/A

4.

Identification Of System Chemical and Volume Control System 5.

(a) Applicable Construction Code:

  • Sec sheet 2, 19 Edition
Addenda, Code Case (b) ApplicableSectionXI Utilized ForRepairsOrReplacements, 19 89 Edition N/A
Addenda, N/A Code Case
6. Identification Of Components Repaired Or Replaced and Replacement Components:

Name Of Name Of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial Number Board Identification Built Replaced Or Code No.

Replacement Stamped (Yes / No)

Load Stud Nut Pacific Scientific Unknown N/A P.O. FNP 2-29 1978 Replaced No Load Stud Nut l

ainnell Unknown N/A P.O. QP3129 1989 Replacement No

7.

Description of Work Snubber SS-4434 was removed from its support by Williams Power Corporation. tested by Wyle Laboratories and was reinstalled by Williams Power Corporation. The load stud nuts damaged during snubber removal were replaced with approved equals.

Ref: MIF 50673 U

8.

Test Conducted

[R Hydrostatic a

Pneumatic [] Normal Operating Pressure 3

None M Other Pressure PSI Temperature F

Form NIS-2 Owner's Report For Repairs Or Replacements As Required By The Provisions Of The ASME Code Section XI RType: L1.52 Job Number E21 -S400356101 I Sheet 2 of 2



11 -

9.

Remarks (Applicable Manuracturer's Data Reports To Be Attached)

  • Pipe hanger was designed to AISC 1969 ED. requirements and welded to AWS D 1.1-86 requirements using material traceability requirements of ASME Section 111.

Certificate of Compliance We certify that the statements made in this report are correct and this replacement conforms to the rules of the ASME Code,Section XI.

repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization Number N/A Expiration Date N/A Signed Date Itg 1 4,l y

{Owner or Owner's Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Achy and Employed by 1,',, - e 7 of

,A1gc7'r a

c i have inspected the components described in this Owner's Report during the period to

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

pf_

Commissions e 3z5

,ZAA Inspe r~'s Signature National Board, State, Province, and Endorsements Date

-.1eo M

Form NIS-2 Owner's Report for Repairs or Replacements As required by the provisions of the ASME Code Section Xl RType: L1.52 Job Number Nil -S400370901 Sheet I of 2

1. Owner
2. Plant Unit Southern Nuclear Operating Company Farley Nuclear Plant 40 Inverness Center Parkway Highway 95 South FNP P

Birmingham, Alabama 35242 Columbia, Alabama 36319 Date (as agent for Alabama Power Company

_November 16.2004

3. Work performed by Type Code Symbol Stamp N/A Name: Southern Nuclear Operatinz Comnany Maintenance Department Authorization Number N/A Address:

Joseph M. Farlev Nuclear Plant Expiration Date N/A

4. Identification of System Main Steam System 5.

(a) Applicable Construction Code:

ASME Section ill, 19 71 Edition Summer 1973

Addenda, N/A Code Case (b) Applicable Section XI Utilized For Repairs Or Replacements, 19 89 Edition N/A
Addenda, N/A Code Case
6. Identification of Components Repaired or Replaced and Replacement Components:

Name of Name of Manufacturer National Other Year

Repaired, ASME Component Manufacturer Serial Number Board Identification Built Replaced, or Code No.

Replacement Stamped (Yes I No)

Disc Assembly Atwood & Morrill FNPSN2 N/A FNP Purhcase Order 2001 Replaced No

_P000393 Disc Assembly Atwood & Morsill FNPSN1S NIA FNP Purchase Order 2004 Replacement Yes

=___

_Q

_P020506

_

rs

7. Description of Work The disc assembly was replaced in QINI IV002B after a regularly scheduled inspection showed normal wear on the assembly. Ref: Transaction Number 50063
8. Test Conducted E

Hydrostatic E

Pneumatic E

Normal Operating Pressure n None [] Other Pressure PSI Temperature OF

Form NIS-2 Owner's Report for Repairs or Replacements As required by the provisions of the ASME Code Section Xl RType: L1.52 Job Number Nl -S400370901 I Sheet 2 of 2 w

p 9. Remarks (Applicable Manufacturer's Data Reports to be attached)

The year built and purchase order numbers represent the most recent refurbishment of the disc assemblies.

The disc assemblies have been reserialized to allow for easier tracibility. See attached for correlation to original serial numbers.

Certificate of Compliance We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl.

repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization Number N/A Expiration Date NIA Signed

/

Maintenance Manager Date 11 bZt/e a Owner or Owner's Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of

_a._,,

and employed by Mve -Go of

^1 o

ver 1_r-A have inspected the components described in this Owner's Report during the period 4*&g M to

,/,/e S

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions e-r 3'Z£7 G

'lm'pictor's Signature National Board, State, Province, and Endorsements Date 117/7S

Main Steam Isolation Valve Code Data Information POST FNP At,ssemblvNumber PostS'EiL-#t ]

P#os1 Yr. O N Stamp1

.EQI sItl

, F N P S N ;.' -.

7 1 i p d r

0 0 tl S N IF

' " ' + -

r.- '. ;

F -

, * * ~M~s\\

41>

E~'

FNS1tFNP-SN1P 4768 OP00393 201 No

',FNPSN1A' F6968' OP0003933,-. 2001.

FNPSNI New #

IN-S-D.')671 PD09.00,,

4 Old

' Mi70Bi69B - '1. 6781 QPi691n

(.1987i'No 6-R-341 64768 QP1691 1987 No 9B'yF6968 >QP,1691 '-StA 1987.

comments: Insi#aIn 12N1iV0QOlB.2R14 ibbfemoIIedV 02N11V001B 2R15 2002; Installed In 02N1 1V0002A In 2R162 2i >:

FNPSN2 NewN t~FNPSN-2D4#2i418*

0P000393.

2O01)-"'J-No -

FNP-SN-2P 27763 CP000393 2001 Yes FNPSW2A 31081 0P0393r206v Old 281 7-25320 27763 67283 1981 Yes r

.'-' i67283.

Comments: Insltald In 2N11Vio02BF2Rl4 200:Riemoved fi 02N11V0002B 2R15 2002; Instaled In OINIIV0002B IR18 2603

--v '-.

FNPSN3 New S

.FNP-SN-30 53350 t 0P600393-2001 -&;NN&.

FNP-SN-3P 49471 OP000393 2001 No FNP-

'F6968" OP 393 2001 Old I

r i 831,',3 35 A 22602'

^1984"' 'iNo,'

49471 22602 1984 No i'-, 9Ak'-`-'- F968'l.

Comments: instae In QiNl 1V02B 1Ri72001 ' Remd from 01 11V00028 iRI8 2003; Installed In 02N1V0002C 2R16 20 04' t

F;r stalle In.¢r *i

^t Ir VOO(i'8Z r-;.a i

st

,,,C;4oC.2,,

,J*.....................

S$r NP NNe iNPS D',-

P 49471 0006 01 Ys~

N-N6.

FNPSN4 Newt tFNP-SN-4O'53350.QPoi0569 2001

  • iNo.rz1/46 FNP-SN-4P 49471 OP010569 21 Yes AN-1-25320,3P010569

,.;2001.

Oidt 3'381')t

  • 53350-=

22 60 1984 2'.No'i 3-30381 49471 22601 1984 Yes I.,1-25=

F7352

!' 673831',f 19805 Comments: Italle In QiN1 WVOO1B9 I R1X001st 3

FNPSN5 New F

29418 tQP000393;.s2001 1',`No; FNP-SN-5P 27763 OP000393 2001 No FNP-SN-5AX-kF69686OP000393-2001 01dM',' 3083lf....

i 29418 4,s2260i

'1984 2,-;-No j 4.25329 27763 22601 1984 No 30381

-69C;'P6968

,22601'

'l9840 Comments:

ista led hI 2N11V0002C2Rt4 200i,' Remor d fro n2N1IVO002C 2R15 2002; Instaed In 02N1 1V0002B in 2R18 I.2004jaw'r^>ri,

.( '9*'-*.v.".-

FNPSN6.

NewN If P S O

~ ~ ~ ~ ~ 20 N

FNP-SN-6P yes aya O*d #

4, 1-23955 24989 1977 Yes Comments: 'Rem from Q2N1iV0002C 2R Wilre NOE rto return of service due to heat numbers associated with FNPSN4(R20i01004781),,

FNPSN7 New iFNPl-SN7D', 53350:Q P0105696';200P. 4 No f'jFNP-SN-7P 44520 OP010569 2001 Yes FNP-SN7A,F7352;:,.iQP01O569' 12001

Old,
2-3083.-

533501 2262,1985.

No 3-25320 44520 21144 1983 Yes v-25320 7352 "

F

'22602

.984' Comments: femoved from 02Nl iVo02B 2R14.1 a1e In a1i N1lVWiC 1R17.

.i

'S FNPSN8 Newli NP-SN8D 67811 O'PO$059 2001 No l.

FNP-SN4P 64678 QP010569 2001 No IFNPSN8A eF6973,0P010569; t,2001 Old

' -3R-340

'67811 FNP-191 ;-

97 9

No 7

3R340 64678 FNP-191 1975 No

¶',

69973.,

2684 1984 Comments: Remo(vedtom2N14V0001B2R1 4. InstanedInOI N11Vooo1 AIR 1 7.

V FNPSN9

New, IFNPSN-9O

'-'678W 0P991i99 2000 0

Yes 0

FNP-SN-9P 64768 OP991099 2000 No FNP-SR'9A F6662:.-'OP991099,2000 O1df k-2R-341, 67811 i 211443 'v1983 YeS

2R341 64768 21144 1983.

No S3-3083l 708 F6662

' 22601;

'984 Comments:'inistSedNIn QNl1V0002A1R7i200i'lhemr10 i11VO002A1R18 2003

-"s' i

.4 FNPSNiO New #

NP.SN.10Dj29418.0P990849. 2009>

N FNP-SN-10P F7763 OP990849 2000 No

FNP-SNA. 'F7352 6P990849 -2000 Old#

14.125320:.'29i18

  • '2I44-.1983

'8N' o 1-25320 F7763 21144 1983 No V.22 F7352-Z*2i144

1983 Comments:Instatledin01NV 020IR170220i720e dtr IV0002CINt 2ClR18203 t,

?

FNPSN1I New#

FNP-SN11D>;

'1.PNP-SN lip

,NPSNA11k

OldM 2.30831.708g 2 02, K1985 No 1.

None None Unknown Unknown No

.1-30831 70A',

22601 1984 Comments: Removwed fro Q1NiiVW02A 1R1i Instlled I 02N1 VO2B 2Rt5 2002; Removed from 02N1 tV0002B In 2R16 2004, FNPSN12 New NP-SN-i2DA t'

' !,FNP-SN-12P

.FNP-SN12A OldM 1-3083170

- r 2260l-':1984 No>:e 2R-340 FNP-191 1975 No sNone, None Unknown Unknov Comments: Removed from Q1INIIVO0002C 1Rli; istalle In Q2NIVO0001B 2R15 2002 Page 1 of 2

Main Steam Isolation Valve Code Data Information r7 POST FNP Assembly Number Poi DHsc sh t-

eQ!;\\ti lilS 1

Q r.Blt. N Stamo FNPSN13 New*

FNP-SN.13Dt -'

P-SN-13P Old t'3R-1 ::

'.FNP222 1975:.No 4 3R-341 64788 FNP2-22 1975 No Comments: 'eAo" d fror QINiIVOOO2B 1Ri7; Ij dfi Q2Nt iV0.00A 2R1s 2002 FNPSN14 NewS FNP.SNi'..

-k'-;FNP-SN 141 Oldl e.25=

38053 o

625320 38053 1985 No Comments: Removed firn OiNiiVOQOIA iRi7-installed In O2tAi V0002C 2R15 2002; Removed from 02N1IV0002C In 2R1e 2 FNPSN15 New t FNP-SN-I5O P-SN.15P Oldi S 2-25320.47 29418 22601+ j9B4ne No 2-25320 27763 22601 1984 No i

Comments: Removed irom Ql1 iVoO0la 1R17, tn.alfed n O2N1 iV0O01C 2R15 2002 FNPSN16 Newr FNP.SN:18D

$i66,

'f

'"'i

^

FNP-SN-16P Oldi i'.4R4 4144-41 : <az'FNP.19L 975 A-'Ye5"'

4R-341 FNP-191 1975 No Comments: A'reIb~IreiomQNliVOO lC iR, Insatalle InI2NI IVOOO2A 2R1152002; Removed from 02N I1V0002A In 2R18 2 FNPSN17 New fNP-SN-i7Dl lOPO2O506

-2003r<'No"r FNP-SN-17P QP02050B 2003 No Old lt

-R1R340"F94P i-91975t-kN:

i 1-340 FNP-191 1975 No Comments: bisiWItbd nQINJiVO O2A iRW 6QO9}6I6 I

FNPSN18 New N FN P

S f

FNP-SN-18P QP020508 2003 OldN #

1N4'VFC'Yes^S1 4-0831 53350 22602 1984 Yes Comments: iNSTALLED 1 Ol1Voo2B URIN0 11l9 FNPSNl9 New FNP SN 19P 0P02030504 2003 Yes OldN 5-5341.

Z 21144-:I983<'

No,

5-R-341 21144 1983 Yes Comments: InstalfedInQitV0062CIRIS2003 F;-,

!ii 11V Page 2 of 2

I I

1.

Ia) uctfedtrbY 1L6W

  • I6.r5vl C
  • uw-.elaeu7u

'*^

.'.s and adI dretsasof NPT Certificate Holder)

(b3 ManufcturedforAlabala Power Co.,P.O. BOXi12641i" Biimlnghim, Ala.

35291 (Navne nd eddrdel of N Certificate Holder for completed nuclear component)

2. Identification.CHrtificete oId Serbtip No. Pan 4-30831 Net'l Sd
o.

N/A CRN No. N/A (a) Ctonstructed According to Drawing No.

71;36-H ReV.

4 Drawing Prepared by BernIe L.

W 1 IMams (bl Description of Part Inspected DtsC Assembly (c Applicable ASYE Code: Section Ill, Edition -

.1 I

.Addenda date5 -73 CaseNo.

NIA Class 2

3. Remarks:

In Kind-Rep-Lacemelt - Retf (Prior AFH S.D. 12340)

(Brief description of service for which component was designed.)

Disc & Post Material are SA 182 Gr.

Fl04

_Dlsc.

Heat~

r~ sws Post Heat No.

is 4q471 For 32" 600# Trip Valve Item 44 inclusive to be completed for singte wall vessels. jackets of jacketed vessels, or shells of heat exchangers.

4.

Shell.

Material

_T.S.

Nom.Thk.ijn. Cort.Allow_in. Oiam._ft.lin. Length.1f._in.

AKino & Spec. No.)

(Men. of range soeclfmcdl

5.

Seams Long__.__.

H.T. '_

_ R.T.

Efliciency Grth H.T.'

R.T.

No.of Courses

6.

Heads: la) Material T.1S.

Ibl Material _T.S.

Location fIop.

Crown Knuckle Elliptical Conical HemisPherical Flat Side to Pressure bottom. enasi ThickneSS Radius Radius Ratio Apoeo Angle Radius Diem.

(convesx or concave)

SaI l

11 removable, bolts used Other fastening_

It Me ial, Spec. No.. T.S.. Size. Number)

Othrfstein (Describe of attech sketch) 1 JJ~e: ClSUre IDescribe as ogee and weld, bar, etc. If bar, give dimensions, if bolted, describe or sketch) oat DRs5n Pressure'_____

ps at

  • F lb) Min. Pressure-Test Temp.
  • F ltms 9 ancl 10 tC. be corrcslelId for lube sections.

9 Trt-Sno-c-Staasonav Daterral_.._

_Dem.

en. Thk. _

n Attachment lKnrl & Spec. No.)

tSuopect to pres.)

(Weldled, bolted)

Float.ng 1.ra:ersal.

.a

_n, Thk._.

  • n. Attachmcnt 10 T

?.eatirebl.

_ ___O.D._.

en Thk..

in. or Sage Nurnber_..

Type (Straight or U) lt.-S t l-t14.-cl ti. top ccnmieted for *nner chambers of jacketed vessels or channels of heat xcchangers.

11 S'.P-l eit_

_'Trl S____

__Nom.Thk._in. Corr.Allow._.n. Diam.Ift._in. Length_1t in.

I K -1 b S.tt NC, I IM.n. of range specifIeol t'

S-.-.s L'.;

_H T.

R.T.____

Efficiency 5e G

H Ti_

No. of Courses 1: 3 fAm

-¢a 1

~

_T.S.___

I-- b).1dersio!___

S_

Cro.n Knuckle Elliptical Conical Hemispherical Flat Side to Pressure cTnc

,.e-ss Fla,us Rardius Ratio Ane. Angle Radius Dieam.

Iconvex or concave) 13 T~n

-0 r, rr In. C-annel.

Ii r

I,'a:s use!C lab)

._Iblb Ic_

._ Other lastening. _

IDeIscribe or attach sketch) t4

..' D.-s--

P--ssure'l

_.D: at

'F lb) M.n. Pressure-Test Temp F

i

-H iS rCIC MtIat : IetAt.

List I w.er inl r ^ai or e-terrnal PresSures witn co ncietnt termrietriure when applicable.

_rr:

ses in trr-r, ests, seitts.

or orfawSnrs may be used rc'to-d: 51) site is 1i42 in. a 31 in.: (2) Information In Items I ata 2 01

?h.$5 Data Report IS incouced on eacn s5e"; and (31 each Sheet is numbtiet and number of sheets is recrierto en item 3, RemarkJs t 2.801 This for-r E00040) may be obtained from the Order Dept., ASME. 345 E. 47th St. New York. N.Y. 1001 7

xag

,.r WR>.

'w*

15. Safety Valve Outlets: Number Size Location___
16. Nozzles:

Purpote (Inlet.

Relntoicment outlet. drain)

Number Diam. or Sise Type Material Thickness Material How Attached

17.

Inspection Manholes:

No..-

.Size

-Location Openings: Handholes:

No.

Size Location Threaded:

No.

Size Location

18.

Supports: Skirt Lugs "LeS:

Other Attached (Yes or no)

(Number)

(Number)

(Describel (Where & howl We certify that the statements made in thus report are correct and this vessel part or appurtenance as defined in the Code conforms to the rules of construction of the ASME Code.Section III.

IThe applicable Design Specification and Design Report are not the responsibiliWy of the NPT Certificate Holder lor parts. An NPT Certificate Holder for appurtenances is responsible for furnishing a separate Design Specification and Design Report if the appurte.

nance is not included in the component Design Specification and Design Report.)

D1t1 i/31

_ 19 R Signed _ATWMODLI0IRRI.L.Q oy

.e

-i__-___

INPT Certificate Holder)

UQ.A. Manage Certificate of Authorization Expires 6-Certificate of Authorization No... 4-:2607 (tJPT)

CERTIFICATION OF DESIGN FOR APPURTENANCE (when applicable)

Design infcsm.uts.,. u file.t _&Aabama _Popwer Co.

Stress *nilvy.s rc;).,'t rn file ;.t tJI.

D-se.r' S
c.'c;ao Le'n, 1

i

'v ed by.

-A. K. Anand_...........

Proc.

Eng. State _Penna._

Reg. No. 2503L.

St,,ts ijnWV':s ept.rt certified by..

J1/A................. __

Prof. Eng. State-14./A-.

Reg. No. S/A CERTIFICATE OF SHOP INSPECTION

-. t.e t- *Jart d

h,'cd n9 a val C comiiss-on issued bv the National Board of Boiler and Pressure Vcssel inspectors and the Slate or I

  • f.- ot assachusetLs and employedtv b

-H.S.B. _J... L.J..- Co.

o 8r t ford, CT. -- ---

ve

-nsisp-ctrr tmeh part of a pressure vessel described in his Part.a Da,.

Rero-s Car.._

Z 19g! and state that. to the best of my knowledge aiAtaieel te-t; T Certificate lolner roas constructed this part in accordance with the ASNE Code. Section Ill.

E. s

%nrr this c*rtl:'cae. "eithertne Ine Inipector nor his employer makes any vsarrantv. expressed or implied, concerning the part de.

sW-*fr

i. !r, pa't.

La.ta Ru-ptl. Furthetrmore, neither the Inspector nor his employer shall be liable in any manner for any personal fr.

(.r l.'-o

'v rZia-1 Cr a If,-- cA any kind aris ng frorn or connected with this ntDection.

-'llet."I'.

/Cc,,nmusorisrc*S&a9/

P'vinc No.

~ " :~e f

t Bfotue

.a i,,i lrri.f^rc. St~s~e. Pro.~jn~e ad No.s

Form NIS-2 Owner's Report for Repairs or Replacements As required by the provisions of the ASME Code Section Xl RType: L1.52 I.

Job Number I

E13 - W020002659 Sheet I of 2 I

6*

1. Owner Southern Nuclear Operating Company 40 Inverness Center Parkway Birmingham, Alabama 35242 (as agent for Alabama Power Company)
2. Plant Farley Nuclear Plant Highway 95 South Columbia, Alabama 36319 Unit FNP I

Date Mav 2. 2000 i.

3. Work performed by Type Code Symbol Stamp N/A Name: Southern Nuclear Operating Company Maintenance Department Authorization Number N/A Address:

Joseph M. Farley Nuclear Plant Expiration Date N/A

4. Identification of System Containment Spray System 5.

(a) Applicable Construction Code:

ASMESectionilI, 19 71 Edition Summer 1971 Addenda.

N/A Code Case (b) Applicable Section XI Utilized For Repairs Or Replacements, 19 89 Edition N/A

Addenda, N/A Code Case
6. Identification of Components Repaired or Replaced and Replacement Components:

Name of Name of Manufacturer National Other Year

Repaired, ASME Component Manufacturer Serial Number Board Identification Built Replaced, or Code No.

Replacement Stamped (Yes / No)

Stud (1)

Texas Bolt Company AE12 N/A P. O. 7047-Q-63631 1975 Replaced No Nut (I6)

TenasBolt Company AE17 N/A P.0. 7047-Q-63631 1975 Replaced No Stud ()

Texas Bolt Company 77130 N/A P..QP991143 2000 Replacement No Nut (16)

Ronson INS8764 N/A P. o. QP991143 1992 Replacement No Manufacturinp-Inc.

I _I

_I

_I I

4

4.

9

+

9 9

I S

I 4-I a

a a

1a I

7. Description of Work Flangeboltingon discharge side ofContainment SprayPump QlE13POOOIAwas found tohave a light boron build-upon iL Bolting failed a subsequent VT-I examination due to corrosion and thread damage. Eight (8) new studs and sixteen (16) new nuts were installed.

Ref: MIF 00039385.

Tb

8. Test Conducted D Hydrostatic r1 Pneumatic 0

NormalOperating!Pressure Lf None R

Other Pressure PSI Temperature "F

Form NIS-2 Owner's Report for Repairs or Replacements As required by the provisions of the ASME Code Section Xl RType: L1.52 I

Job Number I

E13 - W020002659 ISheet 2 of 2 U

9. Remarks (Applicable Manufacturer's Data Reports to be attacbed)

Certificate of Compliance We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section XL repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization Number N/A Expiration Date N/A Signed Maintenance Manager Date l/]

G' Owner or Owner's Designee, Title Certificate of Inservice Inspection 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of j

c Ad and employed by s

e-i of qA

<r f

dhave inspected the components described in this Owner's Report during the period

_________oto

,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

e-1pectoe Siknature I

Commissions Cot

Ze National Board, State, Province, and Endorsements Date