ASME Section XI Inservice Inspection 90-Day Report
ML050540688
Person / Time
Site: Palisades Entergy icon.png
Issue date: 02/15/2005
From: Domonique Malone
Nuclear Management Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML050540688 (67)


Text

INM Palisades Nuclear Plant Com e to 4

He Operated by Nuclear Management Company, LLC Committed to Nuclear Excellec February 15, 2005 ASME, Section Xl, Article IWA-6000 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Palisades Nuclear Plant Docket 50-255 License No. DPR-20 ASME Section Xl Inservice Inspection 90-Day Report By enclosure to this letter, Nuclear Management Company, LLC (NMC) is providing the report for the Inservice Testing Program of Palisades Plant Technical Specification 5.5.7. The American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code, Section Xl, Article IWA-6000 requires that inservice inspection reports be submitted within 90 days following the completion of the most recent refueling outage. The most recent refueling outage for Palisades was completed on November 17, 2004.

Summary of Commitments This letter contains no new commitments and no revisions to existing commitments.

DaniJ. Malone Site Vice President, Palisades Nuclear Plant Nuclear Management Company, LLC Enclosure CC Administrator, Region l1l, USNRC Project Manager, Palisades, USNRC Resident Inspector, Palisades, USNRC 27780 Blue Star Memorial Highway C

Covert, Michigan 49043-9530

- Telephone: 269.764.2000

ENCLOSURE I NUCLEAR MANAGEMENT COMPANY PALISADES NUCLEAR PLANT DOCKET 50-255 February 15, 2005 INSERVICE INSPECTION (ISI) OF CLASS 1, 2 AND 3 SYSTEMS ISI Report 3-7 65 Pages Follow

PALISADES NUCLEAR PLANT ENGINEERING PROGRAMS DEPARTMENT Review and Approval Summary TITLE:

REPORT 3-7 Zzg AIt-

/ZY/zcoaS ISI Engineer

/ MWAcker Date ASMEPro ramsan ValvesSupervisor / DRWilliams Date Engineering Programs~gnager / THFouty' Date/

PALISADES NUCLEAR PLANT 2004 INSERVICE INSPECTION REPORT Submitted in accordance with the American Society of Mechanical Engineers (ASME)

Boiler and Pressure Vessel (B&PV) Code, Section Xl, Article IWA-6000, 1989 Edition.

1. Date:

February 15, 2005

2. Plant Owner:

Consumers Energy 212 West Michigan Avenue Jackson, Michigan 49201

3. Plant:

Palisades Nuclear Plant 27780 Blue Star Memorial Highway Covert, Michigan 49043

4. Unit No:

1

5. Commercial Service Date:

[

6. Major Components Inspected:

I December 31, 1971 Component Pressurizer RPV Head Manufacturer Combustion Eng Combustion Eng Mfg Serial No.

CE-66601 CE-66110 State No.

M96728M M96725M National Board No.

NB20851 NB20827

7. Completion Date for Inspections:
8. Code Inspector:
9. Authorized Inspection Agency:
10. Abstract:

November 17, 2004 Kenneth L Blake Hartford Steam Boiler See ISI Report

2004 INSERVICE INSPECTION 3-7 PALISADES NUCLEAR PLANT Summary Inservice Inspection 3-7 was conducted during the period of April 18, 2003, through November 17, 2004, in accordance with Section 5.5.7 of the Palisades Nuclear Plant Technical Specifications. The American Society of Mechanical Engineers (ASME)

Boiler and Pressure Vessel (B&PV) Code, Section Xl, 1989 Edition controlled the inspections and provided the acceptance criteria for these examinations. Included in this report are two separate sections. Section 1 details the examinations that were performed and provides the final inspection results. Section 2 provides a listing of the repairs and replacements that have been performed over the last operating cycle and during the refueling outage. The attached NIS-2 forms document these repairs and replacements.

Inspection Activities This was the first examination of the third period of the third inspection interval. Areas examined during this inspection included reactor vessel head penetrations and pressurizer penetrations. Various components of the primary coolant system, engineered safeguards system, main steam system, main feedwater system and support systems, as identified in the attached Non-destructive Examination (NDE)

Results Summary Report, were also examined.

The examinations were performed using ultrasonic (UT), liquid penetrant (PT), and visual techniques. The examinations were conducted by the Consumers Energy non-destructive testing (NDT) services department, and Framatome ANP examination personnel, using site-approved procedures. Examinations were performed by personnel qualified in the NDT process, in accordance with the requirements of ASME Section Xl, IWA-2300.

SECTION 1 EXAMINATION DETAILS AND FINAL INSPECTION RESULTS

FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules e3 r

,o

1. Owner Cr r-SFxterS Ersm 2-1 Z \\1jr tCA Xv

%e 03 scs1~e 4t q 2- \\

(Name and Ad ss of Owner)

2. Plant Ru' Z8ic5 ueSorp\\

A 1

Ct q q0 3

'(Name and Address of Plant) j I

I

3. Plant Unit
4. Owner Certificate of Authorization (if required)

N Al5

5. Commercial Service Date 121S31l1M71
6. National Board Number for Unit tAZCU8M7
7. Components Inspected Manufacturer Component or Manufacturer or Installer State or National Appurtenance or Installer Serial No.

Province No.

Board No.

RIN "C.

cEyziv nb~~ov-hcer%-\\aCeE-G(Aio M19(-12SM NR2.082-N 9v C3 Vstuvs5 CF- &GG01 MCG-728h tN87-3

_%V ME

=_______________________'..__________*

Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8MV in. x 11 in.,

(2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82)

This Form (E00029) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y. 10017

FORM NIS-I (B1ack)

8. Examination Dates 'll 8(ZW3 to I Illkoaoq 9. Inspection Interval from 5/IiZIqS-to _7__2Z___o_
10. Abstract of Examinations. Include a list of examinations and a statement concerning status of work required for current interval.

Scc

-p WA E Rqsu\\k Stap on

11. Abstract of Conditions Noted

?

ttS CA Xbs Re\\ks Savvwn"

12. Abstract of Corrective Measures Recommended and Taken We certify that the statements made in this report are correct and the examinations and corrective mea-sures taken conform to the rules of the ASME Code,Section XI.

Certificate of Authorization No. (if applicable) rtt/

Expiration Date rA Date 7^nn VA 2no 6-Signed CVo!

'eBy

/_ZI

/7 Owner CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of MC.t tPV1%..

-ind employed by 1S Mb - C-T of

-have inspected the components described in this Owner's Report during the period Nprml l8)12o0o3 to-t eynt\\Ot-

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

2; Commissions M l 3007 02 Inspector's Signature National Board, State, Province, and Endorsements Date I

c V

(12/82)

PALISADES NDE RESULTS

SUMMARY

NIS 1 Category System Component ID Configuration Disposition Exam Comments AUG ESS FWS ESS-24-SIS-SH1-207 ESS-24-SIS-SH2-207 FWS-3-AWS-tS1-258 FWS-3-AWS-1S1-259 FWS-3-AWS-1Sl-260 FWS-3-AWS-2S1-253 FWS-3-AWS-2S1*254 FWS-3-AWS-2S1-255 FWS-4-AWS-1S1-257 FWS-4-AWS-2S1-252 Check Valve CK-ES3181 to Pipe Check Valve CK-ES 3166 to Tee Elbow to Pipe Pipe to Safe End Safe End to Nozzle Elbow to Pipe Pipe to Safe End Safe End to Nozzle Pipe to Elbow Pipe to Elbow Acceptable Acceptable UTIPT UTIPT Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable UT UT UT UT UT UT UT UT PCS PCS-042 Weld 1 PCS-042 Weld 2 PCS-042 Weld 3 PCS-042 Weld 4 PCS-042 Weld 5 PCS-042 Weld 6 PCS-042 Weld 7 PCS-042 Weld 8 PCS-042 Weld 9 PCS-042 Weld 10 PCS-043 Weld I PCS-043 Weld 2 PCS-043 Weld 3 PCS-043 Weld 4 TE-O11H (Hot Leg TE)

TE-1 12HC (Hot Leg TE)

TE-0112HA (Hot Leg TE)

TE-01 12HD (Hot Leg TE)

TE-0112HB (Hot Leg TE)

TE-0121H (Hot Leg TE)

TE-0122HC (Hot Leg TE)

TE-0122HD (Hot Leg TE)

TE-0122HA (Hot Leg TE)

TE-0122HB (Hot Leg TE)

TE-O4IIA(ColdLegTE)

TE-0112CC (Cold Leg TE)

TE-0112CA (Cold Leg TE)

TE-011 1B (Cold Leg TE)

Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable BM Visual BM Visual BM Visual BM Visual SM Visual BM Visual BM Visual BM Visual BM Visual BM Visual BM Visual BM Visual BM Visual BM Visual 1 of 13

PALISADES NDE RESULTS

SUMMARY

NIS I Category System Component ID PCS-043 Weld 5 PCS-043 Weld 6 PCS-043 Weld 7 PCS-043 Weld 8 PCS-043 Weld 9 PCS-043 Weld 10 PCS-043 Weld 11 PCS-043 Weld 12 PCS-12-SCS-2H1-1 PCS-12-SCS-2H1-2 PCS-2-PSS-1PI-55 PCS-4-PRS-IP 1-1A PCS-72-RCL-2A Configuration TE-0 122CD (Cold Leg TE)

TE-0122CB (Cold Leg TE)

TE-0122CA (Cold Leg TE)

TE-01 22CC (Cold Leg TE)

TE-0121A (Cold Leg TE)

TE-0122CB (Cold Leg TE)

TE-0122CD (Cold Leg TE)

TE-0121B (Cold Leg TE)

Nozzle to Safe End Safe End to Elbow Pipe to Reducer PORV - Safe End to Pipe P-SOC Flywheel Disposition Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Exam BM Visual BM Visual BM Visual BM Visual BM Visual BM Visual BM Visual BM Visual UT UT UT'IPT UT UT Comments PZR PCS-4-PRS-1P1-1 PCS-4-PRS-1P1-1A PCS-4-PSS-1P1-20 PCS-4-PSS-1PI-21 Pressurizer Heater Sleeves Pressurizer T-72 Weld TE-0101 PRZ RV-1039 PRZ RV-1040 PRZ RV-1 041 PZR-002 Weld 1 (LT-0103)

PZR-002 Weld 2 (LT-0 103)

PZR-002 Weld 7 (LT-0103)

PZR-002 Weld 8 (LT-0 103)

PZR-003 Weld 1 (LT-0 102)

PORV - Nozzle to Safe End PORV - Safe End to Pipe SPRAY -Elbow to Safe End SPRAY - Safe End to Nozzle J-Welds (120 Penetrations)

Upper Temperature Element Nozzle to Safe End Nozzle to Safe End Nozzle to Safe End Nozzle to Safe End Safe End to Pipe Nozzle to Safe End Safe End to Pipe Nozzle to Safe End Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable UT BM Visual UT BM Visual UT UT BM Visual BM Visual BM Visual BM Visual BM Visual BM Visual BM Visual EM Visual BM Visual BM Visual 2 of 13

PALISADES NDE RESULTS

SUMMARY

NIS I Category System Component ID PZR-003 Weld 2 (LT-0 102)

PZR-003 Weld 7 (LT.0 102)

PZR-003 Weld 8 (LT-0102)

PZR-004 Weld 1 (LT-01018)

PZR-004 Weld 2 (LT-101B)

PZR-004 Weld 7 (LT.0101B)

PZR-004 Weld 8 (LT-0101E)

PZR-005 Weld 1 (LT-0101A)

PZR-005 Weld 2 (LT-0101A)

PZR-005 Weld 7 (LT-0101A)

PZR-005 Weld 8 (LT-0101A)

TE-0102 Configuration Safe End to Pipe Nozzle to Safe End Safe End to Pipe Nozzle to Safe End Safe End to Pipe Nozzle to Safe End Safe End to Pipe Nozzle to Safe End Safe End to Pipe Nozzle to Safe End Safe End to Pipe (Pad Weld)

Disposition Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Exam BM Visual BM Visual BM Visual BM Visual BM Visual BM Visual BM Visual BM Visual BM Visual EM Visual BM Visual BM Visual Comments RVH 119-01-A 119-02-A 119-03-A 119-04-A 119-05-A 1 1 946-A 11 9-07-A 119-08-A 119-09-A 119-10-A 119-11-A 119-12-A 119-13-A 119-14-A 119-15-A CRD-01 CRD-02 CRD-03 CRD-04 CRD-05 CRD-06 CRD-07 CRD-08 CRD-09 CRD-10 CRD-11 CRD-12 CRD-13 CRD-14 CRD-15 J-Weld J-Weld J-Weld J-Weld J-Weld J-Weld J-Weld J-Weld J-Weld J-Weld J-Weld J-Weld J-Weld J-Weld J-Weld Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable UT BM Visual UT BM Visual UT BM Visual UT BM Visual UT BM Visual UT BM Visual UT BM Visual UT BM Visual UT EM Visual UT BM Visual UT BM Visual UT BM Visual UT BM Visual UT BM Visual UT BM Visual 3 of 13

PALISADES NDE RESULTS

SUMMARY

NIS I Category System Component ID 119-16-A 119-17-A 119-18-A 119-19-A 119-20-A 119-21-A 119-22-A 119-23-A 119-24-A 119-25-A 119-26-A 119-27-A 119-28-A 119-29-A CRD-16 CRD-17 CRD-18 CRD-19 CRD-20 CRD-21 CRD-22 CRD-23 CRD-24 CRD-25 CRD-26 CRD-27 CRD-28 CRD-29 Configuration

J-Weld rJ-Weld

.J-Weld

.1-Weld

.J-Weld IJ-Weld 2J-Weld J-Weld tJ-Weld SJ-Weld

1-Weld

.J-Weld

.J-Weld J-Weld Disposition Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Exam UT BM Visual UT BM Visual UT BM Visual UT BM Visual UT BM Visual UT BM Visual UT BM Visual UT BM Visual UT BM Visual UT BM Visual UT BM Visual UT BM Visual UT BM Visual Comments 119-30-A CRD-30

.- Weld Acceptable 119-31-A 119-32-A 119-33-A 119-34-A 119-35-A 119-36-A 119-37-A 119-38-A 119-39-A 1 19-40-A CRD-31 CRD-32 CRD-33 CRD-34 CRD-35 CRD-36 CRD-37 CRD-38 CRD-39 CRD-40 CRD-41 CRD42 J-Weld J-Weld J-Weld J-Weld J-Weld J-Weld J-Weld J-Weld

.-Weld J-Weld

.-Weld J-Weld Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable UT Weld 119-29-A no longer BM Visual pressure retaining-new weld 119-29-AR Installed with Acceptable results UT Weld 119-30-A no longer EM Visual pressure retaining-new weld 11 9-30-AR Instabed with Acceptable results UT BM Visual UT EM Visual UT BM Visual UT EM Visual UT BM Visual UT BM Visual UT BM Visual UT BM Visual UT BM Visual UT BM Visual UT BM Visual UT BM Visual 119-41-A 119-42-A 4 of 13

PALISADES NDE RESULTS

SUMMARY

NIS I Categcorv System Comoonent ID U

11943-A 1 1944-A 11945-A 119-46 119-47 119-48 Configuration CRD-43 J-Wetd CRD-44 J-Weld CRD45 J-Weld ICI-6 J-Weld ICI-7 J-Weld ICI-8 J-Weld ICI-J-Weld ICI-2 J-Weld IC1-3 J-Weld ICI-4 J-Weld IC-5 J-Weld J-Weld Disposition Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Exam UT BM Visual UT DM Visual UT SM Visual UT BM Visual UT BM Visual UT SM Visual UT SM Visual UT SM Visual UT SM Visual UT SM Visual UT SM Visual UT SM Visual Comments 11949 119-50 119-51 119-52 119-53 RPV Vent Une B-B PZR Pressurizer T-72 Weld 2-983 Upper Head Circumferential Weld Acceptable UT B-G-2 RVH CRDM No. 01 CRDM No. 01N CRDM No. 02 CRDM No. 02N CRDM No. 03 CRDM No. 03N CRDM No. 04 CRDM No. 04N CRDM No. 05 CRDM No. 05N CRDM No. 06 Reactor Vessel CRDM Bolts Reactor Vessel CRDM Nuts Reactor Vessel CRDM Bolts Reactor Vessel CRDM Nuts Reactor Vessel CRDM Bolts Reactor Vessel CRDM Nuts Reactor Vessel CRDM Bolts Reactor Vessel CRDM Nuts Reactor Vessel CRDM BoSls Reactor Vessel CRDM Nuts Reactor Vessel CRDM Bolls Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable VT-1 VT-1 VT-1 VT-1 VT-1 VT-1 VT-1 VT-t VT-1 VT-1 VT-1 5 of 13

PALISADES NDE RESULTS

SUMMARY

NIS I Category System Component ID CRDM No. 06N CRDM No. 07 CRDM No. 07N CRDM No.08 CRDM No. 08N CRDM No.09 CRDM No. 09N CRDM No. 10 CRDM No. ION CROM No.11 CRDM No.11 N CRDM No.12 CRDM No. 12N CRDM No.25 CRDM No. 25N CRDM No.26 CRDM No. 26N CRDM No.27 CRDM No. 27N CRDM No.28 CRDM No. 28N CRDM No.29 CRDM No. 29N CRDM No.30 CRDM No. 30N CRDM No.31 CRDM No. 31N CRDM No.32 Configuration Reactor Vessel CRDM Nuts Reactor Vessel CRDM Bolts Reactor Vessel CRDM Nuts Reactor Vessel CRDM Bolts Reactor Vessel CRDM Nuts Reactor Vessel CRDM Bolts Reactor Vessel CRDM Nuts Reactor Vessel CRDM Bolts Reactor Vessel CRDM Nuts Reactor Vessel CRDM Bolts Reactor Vessel CRDM Nuts Reactor Vessel CRDM Bolts Reactor Vessel CRDM Nuts Reactor Vessel CRDM Bolts Reactor Vessel CRDM Nuts Reactor Vessel CRDM Bolts Reactor Vessel CRDM Nuts Reactor Vessel CRDM Bolts Reador Vessel CRDM Nuts Reactor Vessel CRDM Bolts Reactor Vessel CRDM Nuts Reactor Vessel CRDM Bolts Reactor Vessel CRDM Nuts Reactor Vessel CRDM Bolts Reactor Vessel CRDM Nuts Reactor Vessel CRDM Bolts Reactor Vessel CRDM Nuts Reactor Vessel CRDM Bolts Disposition Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Exam VT-1 VT-1 VT-1 VT-1 VT-i VT-i VT-1 VT-1 VT-i Vr-i VT-I VT-1 VT-1 VT-1 VT-i VT-i VT-1 VT-1 VT-i VT-i VT-I VT-i VT-i VT-1 VT-i VT-1 VT-i VT-i Comments 6 of 13

PALISADES NDE RESULTS

SUMMARY

NIS I Category System Component ID CRDM No. 32N CRDM No. 33 CRDM No. 33N CRDM No. 34 CRDM No. 34N CRDM No. 35 CROM No. 35N CRDM No. 36 CRDM No. 36N CRDM No. 37 CRDM No. 37N CRDM No. 38 CROM No. 38N CRDM No. 39 CRDM No. 39N CRDM No. 40 CRDM No. 40N CRDM No. 41 CRDM No. 41N Configuration Reactor Vessel CRDM Nuts Reactor Vessel CRDM Bolts Reactor Vessel CRDM Nuts Reactor Vessel CRDM Bolts Reactor Vessel CRDM Nuts Reactor Vessel CRDM Bolts Reactor Vessel CRDM Nuts Reactor Vessel CRDM Bolts Reactor Vessel CRDM Nuts Reactor Vessel CRDM Bolts Reactor Vessel CRDM Nuts Reactor Vessel CRDM Bolts Reactor Vessel CROM Nuts Reactor Vessel CRDM Bolts Reactor Vessel CRDM Nuts Reactor Vessel CRDM Bolts Reactor Vessel CRDM Nuts Reactor Vessel CRDM Bolts Reactor Vessel CRDM Nuts Disposition Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Exam VT-i VT-i VT-1 Vr-1 VT-1 VT-1 VT-1 VT-1 VT-i VT-1 VT-i VT-i VT-i VT-i VT-i VT-1 VT-1 VT-1 VT-i Comments B-P PCS Heat Exchangers Piping Pressurizer Pumps Reactor Vessel Steam Generator Valves Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable V`1-2 Vr-2 V`1-2 VT-2 Vr-2 VT-2 V`1-2 7 of 13

PALISADES NDE RESULTS

SUMMARY

NIS I Category System Component ID Configuration Disposition Exam Comments C-H ESS Containment Sump Acceptable VT-2 ESS Pump Suction Acceptable VT-2 High Pressure Safety Injection Acceptable VT-2 System PCS PASM and PCS Sampling System Acceptable VT-2 SDC Shutdown Cooling System Acceptable VT-2 F-A CVC CCS-10-ASH-1PI-PR1A(H7.2A)

Pipe Restraint Acceptable VT-3 CCS-14-ASH-1P1-PR2(H5.1)

Pipe Restraint Acceptable VT-3 CVC-2-CHL-1A2-1APR(H-2.8)

Pipe Restraint Acceptable VT-3 CVC-2-CHL-2A1-39PR1(H-3.18)

Pipe Restraint Acceptable VT-3 CVC-2-CHL-2A1-7PRA(H-3.3)

Pipe Restraint Acceptable VT-3 CVC-2-LDL-281-20PR(H-2.1)

Pipe Restraint Acceptable VT-3 CVC-2-LDL-2B2-21PR(H-1.7)

Pipe Restraint Acceptable VT-3 CVC-2-PSS-IP1-32PRE(H-4.10)

Pipe Restraint Acceptable VT-3 CVC-2-PSS-1P1-52PRB(H-4.1)

Pipe Restraint Acceptable VT-3 ESS ESS-10-SIS-LPA-230PR(H162)

Pipe Restraint Acceptable VT-3 ESS-10-SIS-LPA-231PR(H164)

Pipe Restraint Acceptable VT-3 ESS-2-LTC-1B-26PR(H-732)

Pipe Restraint Acceptable VT-3 ESS-3-SIS-LRA-205PR(H1B)

Pipe Restraint Acceptable VT-3 ESS-4-SIS-HPB-212PR(H201.1)

Pipe Restraint Acceptable VT-3 ESS-6-SIS-lAl-3PR(H-703.4)

Pipe Restraint Acceptable VT.3 ESS-8-CSS-1PA-212PR2(H125)

Pipe Restraint Acceptable VT-3 8 of 13

PALISADES NDE RESULTS

SUMMARY

NIS 1 Category System Component ID ESS-8-CSS-1PA-216PR(H123)

ESS-8-CSS-1PA-218PR(R121.1)

ESS-B-CSS-SLA-231PR1(R883.4)

ESS-8-CSS-SLA-234PR1(R884.9)

ESS-8-CSS-SLA-240PR2(H892)

ESSl-8SIS-1A6-202PSS(H701)

Configuration Pipe Restraint Pipe Restraint Pipe Restraint Pipe Restraint Pipe Restraint Pipe Support Structure Disposition Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Exam VT.3 VT-3 VT.3 Vr-3 Vr-3 VTr-3 Comments MSS PCS MSS-36-MSL-1 SI-202PR(H 14)

MSS-8-MSV-2S2-208PR3(R55.1)

PCS-12.PSL.IH1.SPRA(H-536)

PCS-3-PSS-IB-4PRB(H-1 8)

Pipe Restraint Pipe Restraint Acceptable Acceptable Vr-3 VT-3 Pipe Restraint Pipe Restraint Acceptable Acceptable Vr-3 Vr-3 SFP SFP-1O-FPP-IPA-PR1(HS4)

SFP-10-FPP-IPB-PR2(R85.IA)

SFP.12-SFX-SLI-PRI(H89.1)

Pipe Restraint Pipe Restraint Pipe Restraint Acceptable Acceptable Acceptable VT-3 VT-3 Vr-3 SWS SWS-10-CRS-RL4-PR2(H274)

SWS-6-CRS-2R2-PSSI(H298)

Pipe Restraint Pipe Support Structure Acceptable Acceptable Vr-3 Vr-3 R-A AFW Segment AFW-W10 Segment AFW-1 1 Segment AFW-012 SegmentAFW-016 Segment AFW-01 8 Segment BLD-003 Acceptable Acceptable Acceptable Acceptable Acceptable VT-2 Vr-2 VT-2 Vr-2 Vr-2 BLD Acceptable VT-2 9 of 13

PALISADES NDE RESULTS

SUMMARY

NIS I Category System Component ID Configuration Disposition Exam Comments Segment 1LD-004 Segment BLD-006A Acceptable Acceptable Acceptable VT-2 VT-2 VT-2 CBA Segment CBA-012 Acceptable VT-2 CWS Segment CWS-01 1 Segment CWS-012 Acceptable Acceptable VT-2 VT-2 FWS AFW-016 Weld 251 AFW-016 Weld 252 AFW-016 Weld 253 AFW-016 Weld 254 AFW-016 Weld 255 AFW018 Weld 256 AFW-018 Weld 257 AFW-018 Weld 258 AFW-018 Weld 259 AFW-018 Weld 260 Elbow to Pipe Pipe to Elbow Elbow to Pipe Pipe to Safe End Safe End to Nozzle Elbow to Pipe Pipe to Elbow Elbow to Pipe Pipe to Safe End Safe End to Nozzle Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable UT UT UT UT UT UT UT UT UT UT LPI Segment LPI-001A Segment LPI-002A Segment LPI-003A Segment LPI-004A Segment MSS-048 Segment MSS-049 Acceptable Acceptable Acceptable Acceptable VT-2 VT-2 VT-2 VT-2 MSS Acceptable Acceptable VT-2 VT-2 NSW 10 of 13

PALISADES NDE RESULTS

SUMMARY

NIS 1 Category System Component ID Configuration Disposition Exam Comments Segment NSW-005 Acceptable VT-2 PCS PCS-039 Weld 1 PCS-039 Weld 2 PCS-039 Weld 6 Segment PCS-01 1 Segment PCS-012 Segment PCS-013 Segment PCS-014 Segment PCS-015 Segment PCS-016 Segment PCS-017 Segment PCS-018 Segment PCS-019A Segment PCS-019B Segment PCS-020A Segment PCS-020B Segment PCS-021A Segment PCS-021B Segment PCS-022A Segment PCS-022B Segment PCS-023 Segment PCS-026 Segment PCS-027 Segment PCS-034A Segment PCS-040 Segment PCS-041 Segment PCS-042 Nozzle to Safe End Safe End to Elbow Pipe to Elbow Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable UT UT UT VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 11 of 13

PALISADES NDE RESULTS

SUMMARY

NIS I Category System Component ID Configuration Disposition Exam Comments Segment PCS-043 Acceptable VT-2 PZR PZR-009 Weld 1 PZR-009 Weld 1A PZR-009 Weld 3 PZR-015 Weld 19 PZR-015 Weld 20 PZR-015 Weld 21 Segment PZR-002 Segment PZR-003 Segment PZR.004 Segment PZR-005 Segment PZR-006 Segment PZR-007 Segment PZR-008 Segment PZR-009 Segment PZR-010 Segment PZR-014A Segment PZR-015 Segment PZR-018 Segment PZR-019 Segment PZR-020 PORV - Nozzle to Safe End PORV - Safe End to Pipe Pipe to Elbow Pipe to Elbow SPRAY - Elbow to Safe End SPRAY - Safe End to Nozzle Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable Acceptable UT UT UT UT UT UT VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 SDC Segment SDC-002B1 Segment SDC-005 Segment SDC-006 Segment SDC-009 Segment SDC-001 1A2 Acceptable Acceptable Acceptable Acceptable Acceptable VT-2 VT-2 VT-2 VT-2 VT-2 12 of 13

PALISADES NDE RESULTS

SUMMARY

NIS I Category System Component ID Configuration Disposition Exam Comments Segment SDC-0012A2 Acceptable Vr-2 SSS Segment SSS-OOA Acceptable VT-2 Segment SSS-001B Acceptable VT-2 Segment SSS-002A Acceptable VT-2 Segment SSS-002B Acceptable VT-2 Segment SSS-005A Acceptable Vr-2 Segment SSS-006A Acceptable V7-2 Segment SSS-007 Acceptable VT-2 Segment SSS-008A Acceptable Vr-2 Segment SSS-009 Acceptable Vr-2 13 of 13

SECTION 2 ASME SECTION Xi REPAIRS AND REPLACEMENTS

(

ASME Section Xl Repairs and Replacements The following is a list of the repairs or replacements, which have been performed through the restart from the 2004 refueling outage, for which NIS-2 forms are attached.

Work Order Description of Work 1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

19.

20.

21.

22.

24110781 24110518 24110552 24110782 24422506 24211866 24322215 24322720 24322718 24321117 24422766 24210555 24110546 24323635 24422559 24110866 24322390 24422966 24323693 24323694 24212130 24322358 Replaced Valve MV-SFP101 Replaced Valve MV-SFP102 Replaced Valve MV-SFP103 Replaced Valve MV-SFP104 Replaced Valve CK-CVC2114 Repaired RVH CRDM Penetrations 29 and 30 Replaced Fasteners on Containment Penetration MZ-1 8A Replaced Snubber SNB-62 Replaced Snubber SNB-68 Replaced Snubber SNB-80 Replaced Snubber SNB-79 bolting Replaced Stem and Disc on Valve MO-3011 MV-SW135 CK-ES3339 E-50A Replaced Bonnet Bolt on Valve CV-0872 RV-1 040 Repaired Damaged Gasket Area for Seal Housing CRD-12 Plug 15 tubes in the "A" Steam Generator Plug 3 tubes in the UB" Steam Generator Replace Fasteners on VHX-2 Flange Repaired Inlet Flange on RV-0722

I PALISADES NUCLEAR POWER PLANT FORM NIS-2 OWNER'S REPORT FOR REPAIR/ REPLACEMENT ACTIVITY I

ITEM 121-01¶-::1

1. Owner Consumers Energy Company Name
2. Plant Palisades Nuclear Power Plant Date 1/512005 Sheet 1

of 2

Name 27780 Blue Star Highway, Covert, Ml 49043 Address Nuclear Management Company, LLC WO#24110781 Repair Organization P.O. No., Job No., etc Type Code Symbol Stamp N/A

3. Work Performed by Name 27780 Blue Star Hwy, Covert, Ml 49043 Address
4.

Identification of System SFP

  • Authorization Expiration Date Code Class N/A N/A Class 3
5.

(a) Applicable Construction Code ASME B31.1 1989 Edition Addenda n/a Code Case n/a (b) Applicable Edition of Section Xl Utilized for RepairlReplacement Activity 1989 With No Addenda (c) Applicable Section XI Code Cases None

6.

Identification of Components ASME National Corrected, Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

MV-SFP101 AC Service &

S/N 01 n/a PO# G0254244 1998 Installed No Repair Inc No 4-I.

+

4 4

4.

4 4

4 1

1

.1 J.

f t

4 I

I 4-4-

4 4-4-

I I

4 4-4-

4.

4-4 4

4.

A.

A.

7.

Description of Work Replace Valve MV-SFP101 (Fuel Pool Cooling Pump P-51A Suction Valve)

8.

Tests conducted:

Hydrostatic ]

Pneumatic[]

Nominal Operating Pressure i Exempt E]

Other E Pressure psi Test Temp.

Other:

n/a NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1 /2 in. x 11 in., (2)

Information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and number of sheets is recorded at the top of this form.

-I PALISADES NUCLEAR POWER PLANT FORM NIS-2 OWNER'S REPORT FOR REPAIR/ REPLACEMENT ACTIVITY I 4

ITEM 4

}

9. Remarks None CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section Xi.

Type Code Symbol Stamp N/A Certificate of Auth ation No.

N/A Expiration Date N/A Signed

/i4 z-4 /'

1z

, ASME Program Engineer Date avow> cog hi S

ZOo*

CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by HSR-CT of Connecticut have inspected the components described in this Owner's Report during the period April 18, 2003 to November 17.2004

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury of property damage or a loss of any kind arising from or connected with this inspection.

Commissions Ml 300762 Inspector's Signature National Board, Province and Endorsements Date -/5cenZY S

, OCOS-

PALISADES NUCLEAR POWER PLANT FORM NIS-2 OWNER'S REPORT FOR REPAIR/ REPLACEMENT ACTIVITY ITEM I

'1yI

1.

Owner

2.

Plant Consumers Energy Company Name Palisades Nuclear Power Plant Name 27780 Blue Star Highway, Covert, Ml 49043 Date Sheet 1/5/2005 1

of 2

WO#24110518 Address Repair Organization P.O. No., Job No., etc

3.

Work Performed by Nuclear Management Company, LLC NaeType Code Symbol Stamp N/A Name 27780 Blue Star Hwy, Covert, Ml 49043 Authorization N/A Address Expiration Date N/A

4.

Identification of System SFP Code Class Class 3

5.

(a) Applicable Construction Code ASME B31.1 1989 Edition Edition Addenda n/a Code Case n/a (b) Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 1989 With No Addenda (c) Applicable Section Xl Code Cases None

6.

Identification of Components ASMVE National Corrected, Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

MV-SPF102 AC Service &

S/N 01 n/a PO# P029273 2003 Installed No R ep air

7.

Description of Work

8.

Tests conducted:

Replace Valve MV-SFP102 (Spent Fuel Pool Cooling Pump P-51A Discharge Valve)

Hydrostatic El Other El Pneumaticn Pressure Nominal Operating Pressure Ea psi Test Temp.

Exempt EJ 0 F Other:

n/a NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1 /2 in. x 1 in., (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and number of sheets is recorded at the top of this form.

I PALISADES NUCLEAR POWER PLANT FORM NIS-2 OWNER'S REPORT FOR REPAIR/ REPLACEMENT ACTIVITY I I

ITEM L5 i-

9. Remarks None CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp NIA Certificate of Auth tion No.

NIA Expiration Date NIA Signed

, ASMEProgram Engineer Date

_qkto>!C ZOO CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by HS2-CT of Connecticut have inspected the components described in this Owner's Report during the period April 18, 2003 to November 17.2004

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury of property damage or a loss of any kind arising from or connected with this inspection.

Commissions Ml 300762 Inspector's Signature Date ;ZZAf&4p.S

, o7°°5 National Board, Province and Endorsements

PALISADES NUCLEAR POWER PLANT FORM NIS-2 OWNER'S REPORT FOR REPAIR/ REPLACEMENT ACTIVITY ITEM 1/512005

1. Owner
2.

Plant Consumers Energy Company Name Palisades Nuclear Power Plant Name 27780 Blue Star Highway, Covert, Ml 49043 Date Sheet 1

of 2

WO#24110552 Address Repair Organization P.O. No., Job No., etc

3. Work Performed by Nuclear Management Company, LLC Name Type Code Symbol Stamp N/A 27780 Blue Star Hwy, Covert, Ml 49043 Authorization NIA Address Expiration Date N/A
4.

Identification of System SFP Code Class Class 3

5.

(a) Applicable Construction Code ASME B31.1 1989 Edition Edition Addenda nla Code Case n/a (b) Applicable Edition of Section XI Utilized for Repair/Replacement Activity 1989 With No Addenda (c) Applicable Section XI Code Cases None

6.

Identification of Components ASME National Corrected, Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

MV-SFP103 AC Service &

S/N 01 n/a PO# P800438 2004 Installed No RepairInc No__

4 4

+

+

I 4

4 4

I

+

4.

I 4

7.

Description of Work

8.

Tests conducted:

Replaced Valve MV-SFP103 (Suction Valve for Spent Fuel Pool Cooling Pump P-51B)

Hydrostatic [

Other E PneumatlcD Pressure Nominal Operating Pressure i PSI Test Temp.

Exempt n 0 F Other:

n/a NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1 /2 in. x 11 in., (2)

Information in items 1 through 6 on this report is Included on each sheet, and (3) each sheet is numbered and number of sheets is recorded at the top of this form.

I PALISADES NUCLEAR POWER PLANT FORM NIS-2 OWNER'S REPORT FOR REPAIR/ REPLACEMENT ACTIVITY I ITEM lI t0552

9. Remarks None CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Autho 7'tion No.

NIA Expiration Date N/A Signed

/

ASME Program Engineer Date t

2'z3*

CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by HSB-CT of Connecticut have inspected the components described in this Owner's Report during the period April 18,2003 to November 17.2004

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury of property damage or a loss of any kind arising froT or connected with this inspection.

Commissions Ml300762 Inspector's Signature Date ZAJuASJWe S

National Board, Province and Endorsements

PALISADES NUCLEAR POWER PLANT FORM NIS-2 OWNER'S REPORT FOR REPAIR/ REPLACEMENT ACTIVITY FrEM Ti4"1 7

.-.A 1/5/2005

1. Owner
2. Plant Consumers Energy Company Name Palisades Nuclear Power Plant Date Sheet I

of 2

Name 27780 Blue Star Highway, Covert, Ml 49043 WO#24110782 Address Repair Organization P.O. No., Job No., etc

3. Work Performed by Nuclear Management Company, LLC Name Type Code Symbol Stamp N/A 27780 Blue Star Hwy. Covert, Ml 49043 Authorization N/A Address Expiration Date N/A
4.

Identification of System SFP Code Class Class 3

5.

(a) Applicable Construction Code ASME B31.1 1989 Edition Addenda n/a Code Case n/a (b) Applicable Edition of Section Xi Utilized for Repair/Replacement Activity 1989 With No Addenda (c) Applicable Section Xl Code Cases None

6.

Identification of Components ASME National Corrected, Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

MV-SFP104 AC Service p SIN 01 n/a PO# P800437 2004 Inslalled No

_ _ _ _ _ _ _R e p a i r

7.

Description of Work

8.

Tests conducted:

Replace valve MV-SFP104 (Spent Fuel Pool Cooling Pump P-51B Discharge)

Hydrostatic E Other n Pneumatico Pressure Nominal Operating Pressure i

Exemptn psI Test Temp.

0 F Other n/a NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1 /2 In. x 11 in., (2)

Information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and number of sheets is recorded at the top of this form.

I PALISADES NUCLEAR POWER PLANT FORM NIS-2 OWNER'S REPORT FOR REPAIR/ REPLACEMENT ACTIVITY I I

ITEM 07

9. Remarks None CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this conforms to the requirements of the ASME Code, Section Xi.

Type Code Symbol Stamp N/A Certificate of Authoation No.

N/A Expiration Date N/A -

Signed 1414 1C 9L

. ASME Program Engineer Date jq-o,)

5 f

ZOO CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by HSR-CT I of Connecticut have inspected the components described in this Owner's Report during the period April 18, 2003 to November 17.2004

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xi.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury of property damage or a loss of any kind arising for connected with this inspection.

Commissions MI 300762 Inspector's Signature National Board, Province and Endorsements Date Han~ey s-D C?'OOS

PALISADES NUCLEAR POWER PLANT FORM NIS-2 OWNER'S REPORT FOR REPAIR/ REPLACEMENT ACTIVITY I

ITEM 422506 1/412005

1. Owner
2.

Plant Consumers Energy Company Name Palisades Nuclear Power Plant Name 27780 Blue Star Highway, Covert, Ml 49043 Date Sheet 1

of 2

WO#24422506 Address Repair Organization P.O. No., Job No., etc

3. Work Performed by Nuclear Management Company, LLC Name Typo Code Symbol Stamp N/A NameAuhrztoNA 27780 Blue Star Hwy, Covert, MI 49043 Authorization N/A Address Expiration Date NMA
4.

Identification of System Chemical and Volume Control Code Class Class 1

5.

(a) Applicable Construction Code ANSI 831.1 1989 Edition Addenda N/A Code Case N/A (b) Applicable Edition of Section Xi Utilized for RepairlReplacement Activity 1989 With No Addenda (c) Applicable Section Xl Code Cases N-416-1

6.

Identification of Components ASME National Corrected, Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Charging Line Flowserve-Edward 25AIT n/a G0205574Q 1996 Installed No Loop-1A Check No 2" Elbow Dubose Steel, Inc.

n/a n/a PO# 5026-1989 Installed No 9257 Item 2 N

2" Elbow Dubose Steel, Inc.

n/a n/a PO# 5030-1991 Installed No 43790 Item 6 2" Pipe Dubose Steel, Inc.

n/a n/a PO# 2004-1990 Installed No I_

7277 Item 1

7.

Description of Work

8.

Tests conducted:

Replaced CK-CVC2114 Hydrostatic [

Pneumatico Pressure Nominal Operating Pressure i Exempt E psi Test Temp.

° r Other DI Other Not applicable NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1 /2 in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and number of sheets is recorded at the top of this form.

I PALISADES NUCLEAR POWER PLANT FORM NIS-2 OWNER'S REPORT FOR REPAIR/ REPLACEMENT ACTIVITY I ITEM 2 o;,-,*

9. Remarks None CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp NMA Certificate of Authorization No.

N/A Expiration Date N/A Signed

.44a Y, g / 3t

, ASME Program Engineer Date Z2a&%*

or (d

ZoQ!-

CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by HSn-CT of Connecticut have inspected the components described in this Owner's Report during the period April 18, 2003 to November 17.2004

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury of property damage or a loss of any kind arising from or connected with this inspection.

Commissions M1 300762 inspectors Signature National board, Province and Endorsements Date

$nfuAW?4 5o oas-

I PALISADES NUCLEAR POWER PLANT FORM NIS-2 OWNER'S REPORT FOR REPAIR/ REPLACEMENT ACTIVITY ITEM g

o

,'-1

1. Owner Consumers Energy Company Date 1/4/2005
2.

Plant Name Palisades Nuclear Power Plant Name 27780 Blue Star Highway, Covert, Ml 49043 Sheet 1

of 2

3. Work Performed by Address Framatome ANP WO# 24211866 Repair Organization P.O. No., Job No., etc Type Code Symbol Stamp N/A Name 3315 Old Forest Road, Lynchburg, VA 24506 Authorization Expiration Date Code Class N/A N/A Address
4.

Identification of System PCS

5.

(a) Applicable Construction Code ASME Section III Class 1 1989 Edition Addenda N/A Code Case N-2143-1 (b) Applicable Edition of Section Xi Utilized for Repair/Replacement Activity 1989 With No Addenda (c) Applicable Section Xi Code Cases N-416-1

6.

Identification of Components ASME National Corrected, Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

RPV Head Framatome Weld Rod Heat#

N/A Weld#

2004 Installed CRD Pent #29 NX3804JK 119-29-AR No RPV Head Framatome Weld Rod Heat#

N/A Weld#

2004 Installed CRD Pent #30 NX3804JK 119-30-AR No

7.

Description of Work Repaired CRDM penetrations using ambient temper bead welding per NRC approved Relief Request.

8.

Tests conducted:

Hydrostatic []

Pneumatic[]

Nominal Operating Pressure i Exempt L Other El Pressure psi Test Temp.

a F Other:

NOTE: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size is 8 1 /2 in. xI 1 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and number of sheets is recorded at the top of this form.

PALISADES NUCLEAR POWER PLANT FORM NIS-2 OWNER'S REPORT FOR REPAIR/ REPLACEMENT ACTIVITY ITEM

9. Remarks Reactor Vessel Head CRDM Penetrations J-Groove welds were replaced with new pressure boundary welds in accordance with approved NRC relief request using the ambient temper bead method.

CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this conforms to the requirements of the ASME Code, Section Xi.

Type Code Symbol Stamp N/A Certificate of Authoization No.

N/A Expiration Date N/A Signed

, ASMEProgram Engineer Date

-y iCL M

Z<30c 5 CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by HSR-QT of Connecticut*

have inspected the components described in this Owners Report during the period April 18, 2003 to November 17.2004

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xi.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury of property damage or a loss of any kind arising from or connected with this inspection.

Commissions Ml 300762 Inspector's Signature National Board, Province and Endorsements Date 4AleeAo'Y.S

I PALISADES NUCLEAR POWER PLANT FORM NIS-2 OWNER'S REPORT FOR REPAIR/ REPLACEMENT ACTIVITY ITEM

f225T7,
1. Owner Consumers Energy Company Date 1/412005 Name
2.

Plant Palisades Nuclear Power Plant Name 27780 Blue Star Highway, Covert, MI 49043 Sheet 1

of 2

3.

Work Performed by Address Nuclear Management Company, LLC WO#24322215.

Repair Organization P.O. No., Job No., etc Type Code Symbol Stamp N/A Name 27780 Blue Star Hwy, Covert, MI 49043 Address

4.

Identification of System CIS

5.

(a) Applicable Construction Code ASME B31.1 Authorization Expiration Date Code Class N/A N/A Class 2 1989 Edition Addenda N/A Code Case N/A (b) Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 1989 With No Addenda (c) Applicable Section XI Code Cases None

6.

Identification of Components ASME National Corrected, Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No) 5/8' -11 UNC X Nova Machine N/A N/A PO# G0360383 2001 Installed No 4-1/2" Long Products INC Item 1 l

No 5/8" -11 Heavy Consolidated N/A N/A PO# P801158 2004 Installed Hex Nuts Power Supply Item 2 l

No 4

4 4

4-4.-I 4

7.

Description of Work Replaced Fasteners on Containment Penetration MZ-18A

8.

Tests conducted:

Hydrostatic El PneumaticR Nominal Operating Pressure 0 Exempt [:

Other E Pressure psi Test Temp.

Other.

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1 /2 in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and number of sheets is recorded at the top of this form.

I PALISADES NUCLEAR POWER PLANT FORM NIS-2 OWNER'S REPORT FOR REPAIR/ REPLACEMENT ACTIVITY I ITEM P4322215j77

9. Remarks L

X:>

None CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authoriation No.

N/A Expiration Date N/A Signed i

6

/.

, ASME Program Engineer Date Li CD5 CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by HSB-CT of Connecticut have inspected the components described in this Owner's Report during the period April 18, 2003 to November 17.2004

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury of property damage or a loss of any kind arising from or connected with this inspection.

Commissions M1300762 Inspector's Signature Date

-4cAOAe Y (S' National Board, Province and Endorsements 400oa

l PALISADES NUCLEAR POWER PLANT FORM NIS-2 OWNER'S REPORT FOR REPAIR/ REPLACEMENT ACTIVITY ITEM I

1/4/2005

1. Owner
2.

Plant Consumers Energy Company Name Palisades Nuclear Power Plant Date Sheet 1

of 2

Name 27780 Blue Star Highway, Covert, Ml 49043.

WO#24322720 Address Repair Organization P.O. No., Job No., etc

3. Work Performed by Nuclear Management Company, LLC Name Type Code Symbol Stamp N/A 27780 Blue Star Hwy, Covert, Ml 49043 Authorization N/A Address Expiration Date N/A
4.

Identification of System ESS Code Class Class I

5.

(a) Applicable Construction Code B31.1 1989 Edition Edition Addenda n/a Code Case n/a (b) Applicable Edition of Section XI Utilized for Repair/Replacement Activity 1989 With No Addenda (c) Applicable Section Xl Code Cases None

6.

Identification of Components ASMVE National Corrected, Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Snubber Fronek AIDEINC ADH-1000 n/a PO# G0284322 1999 Installed No SNB-62 S/N 2488

7.

Description of Work

8.

Tests conducted:

Scheduled Snubber Replacement per Snubber Program Hydrostatic n Other E Pneumatlco Pressure Nominal Operating Pressure L Exempt Li psi Test Temp.

° F Other VT-3 of replacement snubber NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1 /2 in. xI 1 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and number of sheets is recorded at the top of this form.

I PALISADES NUCLEAR POWER PLANT FORM NIS-2 OWNER'S REPORT FOR REPAIR/ REPLACEMENT ACTIVITY I ITEM E-72O??7 al

9. Remarks None CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section Xi.

Type Code Symbol Stamp N/A Certificate of Authori tion No.

NMA Expiration Date NIA Signed ASME Program Engineer Date 1C0QZ LA a&

CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by HSB-CT of Connecticut have inspected the components described in this Owners Report during the period April 18, 2003 to November 17.2004

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury of property damage or a loss of any kind ariemn onycted with this inspection.

Commissions Ml 300762 Inspectotr's Signature Date 34ulAZS So National Board, Province and Endorsements

. 0200S

.1 PALISADES NUCLEAR POWER PLANT FORM NIS-2 OWNER'S REPORT FOR REPAIR/ REPLACEMENT ACTIVITY ITEM 1/1012005

1. Owner
2.

Plant Consumers Energy Company Name Palisades Nuclear Power Plant Name 27780 Blue Star Highway, Covert, MI 49043 Date Sheet I

of 2

WO#24322718 Address Repair Organization P.O. No., Job No., etc

3. Work Performed by Nuclear Management Company, LLC Name Type Code Symbol Stamp N/A 27780 Blue Star Hwy, Covert, Ml 49043 Authorization N/A Address Expiration Date N/A
4.

Identification of System ESS Code Class Class I

5.

(a) Applicable Construction Code ASME B31.1 1973 Edition Addenda n/a Code Case n/a (b) Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 1989 With No Addenda (c) Applicable Section Xi Code Cases None

6.

Identification of Components ASMVE National Corrected, Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Snubber BASIC-PSA INC.

S/N42298 n/a PO#P029531 2003 Installed No S N B -6 8

7.

Description of Work

8.

Tests conducted:

Scheduled Snubber Replacement per Snubber Program Hydrostatic M Other i Pneumaticrl Pressure Nominal Operating Pressure n psi Test Temp.

Exempt n 0F Other VT-3 of replacement snubber NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1 /2 in. x 11 in., (2) information in items 1 through 6 on this report is Included on each sheet, and (3) each sheet Is numbered and number of sheets is recorded at the top of this form.

I PALISADES NUCLEAR POWER PLANT FORM NIS-2 OWNER'S REPORT FOR REPAIR/ REPLACEMENT ACTIVITY I ITEM,432.7 1

9. Remarks None CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Auth zation No.

N/A Expiration Date N/A Signed 7/'

zz 4Q

, ASME Program Engineer Date

a2v)

Q ZOOS CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by HSB-CT of Connecticut have inspected the components described in this Owner's Report during the period April 18, 2003 to November 17.2004

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury of property damage or a loss of any kind arising from or connected with this inspection.

Commissions Ml 300762 Inspector's Signature National Board, Province and Endorsements Date :;A qY //

PALISADES NUCLEAR POWER PLANT FORM NIS-2 OWNER'S REPORT FOR REPAIR/ REPLACEMENT ACTIVITY ITEM El 1/10/2005

1. Owner
2. Plant Consumers Energy Company Name Palisades Nuclear Power Plant Date Sheet 1

of 2

Name 27780 Blue Star Highway, Covert, Ml 49043 WO# 24321117 Address Repair Organization P.O. No., Job No., etc

3. Work Performed by Nuclear Management Company, LLC Name Type Code Symbol Stamp N/A 27780 Blue Star Hwy, Covert, Ml 49043 Authorization N/A Address Expiration Date N/A
4.

Identification of System ESS Code Class 1

5.

(a) Applicable Construction Code ASME B31.1 1973 Edition Addenda n/a Code Case n/a (b) Applicable Edition of Section Xi Utilized for RepairlReplacement Activity 1989 With No Addenda (c) Applicable Section Xi Code Cases None

6.

Identification of Components ASME National Corrected, Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

SNB-80 BASIC-PSA INC S/N#41724 n/a PO#P025747 2003 Installed No Bolt 1/4" -20 BASIC-PSA INC n/a n/a PO#P804287 2004 Installed No I I I

7.

Description of Work

8.

Tests conducted:

Replaced snubber with spare Hydrostatic []

Other i PneumatlcE Pressure Nominal Operating Pressure LI psi Test Temp.

Exempt E 0F Other VT-3 NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1 /2 in. x 11 In., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and number of sheets Is recorded at the top of this form.

I PALISADES NUCLEAR POWER PLANT FORM NIS-2 OWNER'S REPORT FOR REPAIR/ REPLACEMENT ACTIVITY I ITEM

9. Remarks None CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp NMA Certificate of Authorization No.

N/A Expiration Date N/A Signed

/iy/

"Z/641

, ASME Program Engineer Date tk

200, z

CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by HSR-CT of Connecticut have inspected the components described in this Owner's Report during the period April 18, 2003 to November 17.2004

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury of property damage or a loss of any kind arising from or connected with this inspection.

H e

Commissions M1 300762 Inspectors Signature National Board, Province and Endorsements Date ZiAqdtluAY /Z-I.200s-

PALISADES NUCLEAR POWER PLANT FORM NIS-2 OWNER'S REPORT FOR REPAIR/ REPLACEMENT ACTIVITY ITEM N&2166 111012005

1.

Owner

2.

Plant Consumers Energy Company Name Palisades Nuclear Power Plant Date Sheet 1

of 2

Name 27780 Blue Star Highway, Covert, MI 49043 WO#24422766 Address Repair Organization P.O. No., Job No., etc

3. Work Performed by Nuclear Management Company, LLC Name Type Code Symbol Stamp N/A 27780 Blue Star Hwy, Covert, Ml 49043 Authorization N/A Address Expiration Date NMA
4.

Identification of System ESS Code Class Class 1

5.

(a) Applicable Construction Code ASME B31.1 1989 Edition Addenda n/a Code Case nla (b) Applicable Edition of Section XI Utilized for Repair/Replacement Activity 1989 With No Addenda (c) Applicable Section XI Code Cases None

6.

Identification of Components ASME National Corrected, Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

SNB-79 bolting BASIC-PSA INC n/a n/a PO#P804287 2004 Installed No

7.

Description of Work

8.

Tests conducted:

SNB-79 Replaced Fasteners Hydrostatic ]

Other i Pneumatico Pressure Nominal Operating Pressure 2 psi Test Temp.

Exempt n

° F Other:

VT-3 NOTE: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size is 8 1 /2 in. x 11 in., (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and number of sheets is recorded at the top of this form.

PALISADES NUCLEAR POWER PLANT FORM NIS-2 OWNER'S REPORT FOR REPAIR/ REPLACEMENT ACTIVITY ITEM _

27

9. Remarks None CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Auth 7 ationNo.

N/A Expiration Date N/A Signed

//

4 f

4%

, ASME Program Engineer Date 7

W IO 2C!)z 5 CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by HSB-CT of Connecticut have inspected the components described in this Owners Report during the period April 18, 2003 to November 17.2004

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury of property damage or a loss of any kind arising from or connected with this inspection.

Commissions M1300762 Inspectors Signature Date 0TJA.C'/0 National Board, Province and Endorsements 1 2osO

PALISADES NUCLEAR POWER PLANT FORM NIS-2 OWNER'S REPORT FOR REPAIR/ REPLACEMENT ACTIVITY ITEM z421

-55 _ I 1/4/2005

1. Owner Consumers Energy Company Date
2. Plant Name Palisades Nuclear Power Plant Name 27780 Blue Star-Highway, Covert, Ml 49043 Sheet 1

of 2

WO# 24210555 Address Repair Organization P.O. No., Job No., etc

3. Work Performed by Nuclear Management Company, LLC Name Type Code Symbol Stamp N/A Name 27780 Blue Star Hwy, Covert. Ml 49043 Authorization N/A Address Expiration Date N/A
4.

Identification of System ESS Code Class 2

5.

(a) Applicable Construction Code ASME Section III 1974 Edition Edition Addenda n/a Code Case n/a (b) Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 1989 With No Addenda (c) Applicable Section XI Code Cases None

6.

Identification of Components ASME National Corrected, Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Valve Disc Velan Valve Corp.

P/N 1559-15-121 n/a PO#1002-2373 1981 Installed No Valve Stem Velan Valve Corp.

P/N 1547-057-072 n/a PO#1003-0728 1982 Installed No

7.

Description of Work Replaced stem and disc on valve MO-3011

8.

Tests conducted:

Hydrostatic g Other M Pneumatics Pressure Nominal Operating Pressure I

Exemptm psi Test Temp.

0 F Other:

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1 /2 in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and number of sheets is recorded at the top of this form.

PALISADES NUCLEAR POWER PLANT FORM NIS-2 OWNER'S REPORT FOR REPAIR/ REPLACEMENT ACTIVITY ITEM

L.

S

9. Remarks None CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Author ion No.

N/A Expiration Date N/A Signed I XSME Program Engineer Date L

.i 2...

CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by HSR-CT of Connecticut have inspected the components described in this Owner's Report during the period April 18, 2003 to November 17.2004

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury of property damage or a loss of any kind arising fro or connected with this inspection.

Commissions Ml 300762 Inspector's Signature National Board, Province and Endorsements Date ieeA14,q1 S

I PALISADES NUCLEAR POWER PLANT FORM NIS-2 OWNER'S REPORT FOR REPAIR/ REPLACEMENT ACTIVITY I

ITEM 2411054

1. Owner Consumers Energy Company Name
2.

Plant Palisades Nuclear Power Plant Date 1/10/2005 Sheet 1

of 2

Name 27780 Blue Star Highway, Covert, Ml 49043 Address Nuclear Management Company, LLC WO#241 10546 Repair Organization P.O. No., Job No., etc Type Code Symbol Stamp NMA

3.

Work Performed by Name 27780 Blue Star Hwy, Covert, Ml 49043 Address

4.

Identification of System SWS

5.

(a) Applicable Construction Code ASME B31.1 Authorization Expiration Date Code Class N/A N/A Class 3 1989 Edition Edition Addenda n/a Code Case n/a (b) Applicable Edition of Section Xi Utilized for Repair/Replacement Activity 1989 With No Addenda (c) Applicable Section Xl Code Cases None

6.

Identification of Components ASME National Corrected, Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No) 4' Flange Energy Steel n/a n/a PO#P800595 2004 Installed No MV-SW135 Divesco n/a n/a PO# P804415 2004 Installed No V alve__

t

.t

.t 1*

4-t 4-4 4-4-

4

7.

Description of Work Replaced Valve MV-SW135

8.

Tests conducted:

Hydrostatic E]

Pneumatlcm Nominal Operating Pressure R Exempt LI Other M Pressure psi Test Temp.

Other n/a NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size Is 81 /2 in. x 11 in., (2)

Information in items 1 through 6 on this report Is included on each sheet, and (3) each sheet is numbered and number of sheets is recorded at the top of this form.

I PALISADES NUCLEAR POWER PLANT FORM NIS-2 OWNER'S REPORT FOR REPAIR/ REPLACEMENT ACTIVITY -I ITEM

9. Remarks None CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section Xi.

Type Code Symbol Stamp N/A Certificate of Autho ization No.

N/A Expiration Date NIA Signed

/ 4> '

A &

ASME Program Engineer Date

_c__Us,_

CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michiqan and employed by HSR-CT of Connecticut have inspected the components described in this Owner's Report during the period April 18, 2003 to November 17.2004

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury of property damage or a loss of any kind arising from or connected with this inspection.

Commissions Ml 300762 Inspector's Signature Date J/fA I

/ 9

,___s_

National Board, Province and Endorsements

z PALISADES NUCLEAR POWER PLANT FORM NIS-2 OWNER'S REPORT FOR REPAIR/ REPLACEMENT ACTIVITY ITEM 77,

1. Owner Consumers Energy Company Name
2.

Plant Palisades Nuclear Power Plant Date Sheet 1/8/2005 1

of 2

Name 27780 Blue Star Highway. Covert, Ml 49043 WO#24323635 Address Repair Organization P.O. No., Job No., etc

3.

Work Performed by Owner NameType Code Symbol Smp NA Same Authorization N/A Address Expiration Date N/A

4. Identification of System ESS Code Class Class 2
5.

(a) Applicable Construction Code ASME B31.1 1989 Edition Addenda n/a Code Case n/a (b) Applicable Edition of Section Xi Utilized for Repair/Replacement Activity 1989 With No Addenda (c) Applicable Section XI Code Cases N416-1

6.

Identification of Components ASME National Corrected, Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Chesk Valve Flowserve US INC S/N 21AXS n/a PO# P030853 2003 Installed No C K -ES3339 Valve disc Flowserve U n/a n/a PO# P028851 2003 Installed No 2" Pipe Chicago Tube &

n/a n/a PO#1007-1744 1986 Installed No Iron 2" Elbow Tioga Pipe n/a n/a PO# G0224250 1997 Installed No Sup Co

7.

Description of Work Replaced Check Valve CK-ES3339

8.

Tests conducted:

Hydrostatic e Pneumatlcf Pressure Nominal Operating Pressure psi Test Temp.

Exempt Fn a F Other LI Other n/a NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1 /2 in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and number of sheets is recorded at the top of this form.

I PALISADES NUCLEAR POWER PLANT FORM NIS-2 OWNER'S REPORT FOR REPAIR/ REPLACEMENT ACTIVITY ITEM 46:T1.

9. Remarks None CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Auhor ation No.

N/A Expiration Date N/A Signed ASME Program Engineer Date qaKqc I8 Zo05 CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by HSR-CT of Connecticut have inspected the components described in this Owner's Report during the period April 18, 2003 to November 17.2004

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury of property damage or a loss of any kind arising from or connected with this inspection.

Commissions Ml 300762 Inspector's Signature Date JAXW,?/Z

/1 National Board, Province and Endorsements

PALISADES NUCLEAR POWER PLANT FORM NIS-2 OWNER'S REPORT FOR REPAIR/ REPLACEMENT ACTIVITY ITEM z42256V':-

1/17/2005

1. Owner
2. Plant Consumers Energy Company Name Palisades Nuclear Power Plant Name 27780 Blue Star Highway, Covert, Ml 49043 Date Sheet I

of 2

WO#24422559 Address Repair Organization P.O. No., Job No., etc

3. Work Performed by Westinghouse Electric Company Type Code Symbol Stamp N/A Name P.O.Box 355, Pittsburg,PA 15230 Authorization N/A Address Expiration Date N/A
4.

Identification of System PCS Code Class Class 1

5.

(a) Applicable Construction Code ASME Section III 1989 Edition Addenda n/a Code Case n/a (b) Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 1989 With No Addenda (c) Applicable Section Xl Code Cases None

6.

Identification of Components ASME National Corrected, Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Helicoil for 1-ABB Combustion n/a n/a PO#G0223583 1998 Installed No 5/8" stud hole Eng Nuclear POW No 1-5/8" Washer ABB Combustion n/a n/a PO#G0191526 1996 Installed Eng Nuclear POW No 1-5/8" Nut Nova machine n/a n/a PO#G0310446 1999 Installed No Products 1-5/8" Stud Westinghouse n/a n/a PO#P040490 2003 Installed No Electric Co

7.

Description of Work

8.

Tests conducted:

Repaired Stud Hole #5 with Helicoil and Installed new Stud, Nut and Washer on E-50A Manway Hydrostatic Other 2 PneumaticU Pressure Nominal Operating Pressure i psi Test Temp.

Exempt L 0F Other:

n/a NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet Is numbered and number of sheets is recorded at the top of this form.

I PALISADES NUCLEAR POWER PLANT FORM NIS-2 OWNER'S REPORT FOR REPAIR/ REPLACEMENT ACTIVITY I

_TE --

ITEM Z422559 -q - : I-

9. Remarks None CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Autlorization No.

N/A Expiration Date N/A Signed e "4VI,/

6

, ASME Program Engineer Date I -I I

ZoC0

  • CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by HS2-CT of Connecticut have inspected the components described in this Owner's Report during the period April 18, 2003 to November 17.2004

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury of property damage or a loss of any kind arising from r connected with this inspection.

Commissions Ml 300762 Inspector's Signature National Board, Province and Endorsements Date a

-9 0700's-

I PALISADES NUCLEAR POWER PLANT FORM NIS-2 OWNER'S REPORT FOR REPAIR/ REPLACEMENT ACTIVITY ITEM 0866 1/13/2005

1. Owner
2.

Plant Consumers Energy Company Name Palisades Nuclear Power Plant Name 27780 Blue Star Highway, Covert, Ml 49043 Date Sheet 1

of 2

WO#24110866 Address Repair Organization P.O. No., Job No., etc

3.

Work Performed by Nuclear Management Company, LLC Name Type Code Symbol Stamp N/

27780 Blue Star Hwy, Covert, MI 49043 Authorization N/A Address Expiration Date N/A

4.

IdentIfication of System MSS Code Class Class 2

5.

(a) Applicable Construction Code ASME B31.1 1989 Edition Addenda n/a Code Case n/a (b) Applicable Edition of Section XI Utilized for RepairlReplacement Activity 1989 With No Addenda (c) Applicable Section XI Code Cases None

6.

Identification of Components ASME National Corrected, Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

CV-0782 Energy &

n/a n/a PO#P032250 2003 Installed Bonnet bolt Process No 4

4 4

4.
4.

I 4

4 4

4

4.

4.I I

4 4

4

4.
4.

I 4

4 4

.1

1.
4.

I 4

7.

Description of Work

8.

Tests conducted:

Replace Bonnet bolt on Atmospheric Dump Valve CV-0782 Hydrostatic L Other E Pneumatico Pressure Nominal Operating Pressure psi Test Temp.

Exempt L

° F Other n/a NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1 /2 in. x 11 in., (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and number of sheets is recorded at the top of this form.

I PALISADES NUCLEAR POWER PLANT FORM NIS-2 OWNER'S REPORT FOR REPAIR/ REPLACEMENT ACTIVITY I ITEM 6

9. Remarks None CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate ofAuth*ation No.

N/A Expiration Date NIA Signed

/e f

f i

ASME Program Engineer Date

____11 13 2

CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by HSR-CT of Connecticut have inspected the components described in this Owner's Report during the period April 18, 2003 to November 17,2004

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xi.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury of property damage or a loss of any kind arising from or connected with this inspection.

Commissions Ml 300762 Inspector's Egnature National Board, Province and Endorsements Date vA/4cci"

/} 7 goo0se

I PALISADES NUCLEAR POWER PLANT FORM NIS-2 OWNER'S REPORT FOR REPAIR/ REPLACEMENT ACTIVITY ITEM 422390~ij 111312005

1. Owner Consumers Energy Company Name
2.

Plant Palisades Nuclear Power Plant Date Sheet 1

of 2

Name 27780 Blue Star Highway, Covert, Ml 49043 WO#24322390 Address Nuclear Management Company, LLC

3.

Work Performed by Repair Organization P.O. No., Job No., etc Type Code Symbol Stamp N/A Name 27780 Blue Star Hwy, Covert, Ml 49043 Address

4.

Identification of System PCS Authorization Expiration Date Code Class N/A N/A Class I S.

(a) Applicable Construction Code ASME Section III Addenda n/a 1986 Edition Code Case n/a (b) Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 1989 With No Addenda (c) Applicable Section XI Code Cases None

6.

Identification of Components ASME National Corrected, Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

RV-1040 Valve Dresser Industries n/a n/a PO#G0265252 1998 Installed No Disc

7.

Description of Work Replaced Valve Disc RV-1 040

8.

Tests conducted:

Hydrostatic []

Pneumatlcn l Nominal Operating Pressure i Exempt L Other El Pressure psi Test Temp.

Other:

n/a NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1 /2 in. x 11 in., (2) information in items 1 through 6 on this report Is included on each sheet, and (3) each sheet is numbered and number of sheets is recorded at the top of this form.

PALISADES NUCLEAR POWER PLANT FORM NIS-2 OWNER'S REPORT FOR REPAIR/ REPLACEMENT ACTIVITY ITEM Bi22g 77~TI

9. Remarks None CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed

-ASME Program Engineer Date 2Ioo CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michican and employed by HS8-CT of Connecticut have inspected the components described in this Owner's Report during the period April 18, 2003 to November 17,2004 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section Xi.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury of property damage or a loss of any kind arising from r connected with this inspection.

Commissions M1 300762 Inspector's Signature National Board, Province and Endorsements Date 37 Aeo4P A

I PALISADES NUCLEAR POWER PLANT FORM NIS-2 OWNER'S REPORT FOR REPAIR/ REPLACEMENT ACTIVITY ITEM f 4

1

1. Owner Consumers Energy Company Date 1/10/2005 Name
2.

Plant Palisades Nuclear Power Plant Name 27780 Blue Star Highway, Covert, Ml 49043 Sheet I

of 2

Address PCI Energy Services WO#24422966 Repair Organization P.O. No., Job No., etc Type Code Symbol Stamp N/A

3. Work Performed by Name One Energy Drive, Lake Bluff, IL 60044 Address
4.

Identification of System PCS

5.

(a) Applicable Construction Code ASME Section III Authorization Expiration Date Code Class N/A N/A Class 1 1986 Edition Addenda 1988 Code Case nta (b) Applicable Edition of Section XI Utilized for RepairlReplacement Activity 1989 With No Addenda (c) Applicable Section Xl Code Cases None

6.

Identification of Components ASME National Corrected, Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

CRD-12 Upper Ionics, Inc.

n/a n/a PO#P804708 2001 Corrected Yes Housing

7.

Description of Work Repaired Damaged gasket seating area on CRDM-12 upper housing

8.

Tests conducted:

Hydrostatic [

PneumatIcE Nominal Operating Pressure i

Exempt gl Other M Pressure psi Test Temp.

a F Other:

PT NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1 /2 in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and number of sheets is recorded at the top of this form.

I PALISADES NUCLEAR POWER PLANT FORM NIS-2 OWNER'S REPORT FOR REPAIR/ REPLACEMENT ACTIVITY I ITEM 22966 i;>E,

9. Remarks Weld repair and machining of CRD-12 upper housing performed by PCI Energy Services CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section Xi.

Type Code Symbol Stamp N/A Certificate of Authoriz tion No.

NJA Expiration Date NIA Signed

/4 a'0 6

, ASME Program Engineer Date.;C3 ~vI2.1 ZC0s CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by HSB-CT of Connecticut have inspected the components described in this Owner's Report during the period April 18, 2003 to November 17.2004

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury of property damage or a loss of any kind arising fromgr connected with this inspection.

Commissions Ml 300762 Inspector's Signature Date IaAiAl, k-l National Board, Province and Endorsements coo.S

PALISADES NUCLEAR POWER PLANT FORM NIS-2 OWNER'S REPORT FOR REPAIR/ REPLACEMENT ACTIVITY ITEM I2-3236-r

1. Owner
2. Plant Consumers Energy Company Name Palisades Nuclear Power Plant Name 27780 Blue Star Highway, Covert, Ml 49043 Date Sheet 1

of 2

WO#24323693 Address Repair Organization P.O. No., Job No., etc

3. Work Performed by Owner NaeType Code Symbol Stamp N/A Name Same Authorization N/A Address Expiration Date N/A
4.

Identification of System PCS Code Class Class 1

5.

(a) Applicable Construction Code ASME Section il, 1977 Edition Addenda n/a Code Case n/a (b) Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 1989 With No Addenda (c) Applicable Section Xl Code Cases None

6.

Identification of Components ASME National Corrected, Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Tube Plugs Westinghouse n/a n/a PO#P800987 2004 Installed No Electric Company l

7.

Description of Work

8.

Tests conducted:

Plugged 15 tubes in the 'A" Steam Generator Hydrostatic E Other g PneumaticFE Pressure Nominal Operating Pressure E psi Test Temp.

Exempt E

° F Other NOTE: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size is 8 1 /2 in. x 11 In., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and number of sheets is recorded at the top of this form.

I PALISADES NUCLEAR POWER PLANT FORM NIS-2 OWNER'S REPORT FOR REPAIR/ REPLACEMENT ACTIVITY I ITEM

-369

9. Remarks None CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section Xi.

Type Code Symbol Stamp N/A Certificate of Aut rization No.

N/A Expiration Date NIA Signed

/$?4,/4/

6. 4/.

. ASME Program Engineer Date J5I 70o l

CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by HSB-CT of Connecticut have inspected the components described in this Owners Report during the period April 18, 2003 to November 17.2004

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury of property damage or a loss of any kind arising from or connected with this inspection.

Commissions Ml 300762 Inspector's Signature Date j';AItA/C> If National Board, Province and Endorsements

PALISADES NUCLEAR POWER PLANT FORM NIS-2 OWNER'S REPORT FOR REPAIR/ REPLACEMENT ACTIVITY ITEM

1. Owner
2.

Plant Consumers Energy Company Name Palisades Nuclear Power Plant Name 27780 Blue Star Highway, Covert, Ml 49043 Date Sheet 1

of 2

WO#24323694 Address Repair Organization P.O. No., Job No., etc

3. Work Performed by Owner Name Type Code Symbol Stamp N/A Same Authorization N/A Address Expiration Date N/A
4.

Identification of System PCS Code Class Class 1

5. (a) Applicable Construction Code ASME Section III 1977 Edition Addenda nla Code Case n/a (b) Applicable Edition of Section XI Utilized for RepairlReplacement Activity 1989 With No Addenda (c) Applicable Section Xl Code Cases None
6.

Identification of Components ASME National Corrected, Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Tube Plugs Westinghouse n/a n/a PO#P800987 2004 Installed No Electric Company No

_ I

_ I I __

I I

I _

_ I _

7.

Description of Work

8.

Tests conducted:

Plugged 3 tubes In the ABE Steam Generator Hydrostatic E Other D PneumaticCl Pressure Nominal Operating Pressure'

]

psi Test Temp.

Exempt 0 Other NOTE: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size is 8 1 /2 in. x 11 in., (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and number of sheets is recorded at the top of this form.

I PALISADES NUCLEAR POWER PLANT FORM NIS-2 OWNER'S REPORT FOR REPAIR/ REPLACEMENT ACTIVITY I ITEM Pi32j 94,7i S

9. Remarks None CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed 49 2,;,//VJ i

. ASME Program Engineer Date t

a) 20 Oa CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by HBR-CT of Connecticut have inspected the components described in this Owner's Report during the period April 18,2003 to November 17.2004

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury of property damage or a loss of any kind arising from or connected with this inspection.

Commissions MI 300762 Inspector's Signature Date ZJAkq&e. 5 /?

National Board, Province and Endorsements

PALISADES NUCLEAR POWER PLANT FORM NIS-2 OWNER'S REPORT FOR REPAIR/ REPLACEMENT ACTIVITY ITEM >4213

1. Owner Consumers Energy Company Name
2.

Plant Palisades Nuclear Power Plant Date Sheet 1/19/2005 1

of 2

Name 27780 Blue Star Highway, Covert, MI 49043 WO#24212130 Address Owner

3. Work Performed by Repair Organization P.O. No., Job No., etc Type Code Symbol Stamp N/A Authorization N/A Name Same Address
4.

Identification of System CRS S. (a) Applicable Construction Code ASME B31.1 Addenda n/a Expiration Date Code Class N/A 3

1989 Edition Code Case n/a (b) Applicable Edition of Section Xl Utilized for RepairlReplacement Activity 1989 With No Addenda (c) Applicable Section Xl Code Cases None

6.

IdentificatIon of Components ASME National Corrected, Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No) 5/8"-11 X 4" Nova Machine n/a n/a PO#P801470 2004 Installed N

Studs Products No 5/8"-11 Nuts Consolidated n/a n/a PO#P801158 2004 Installed N

Power Supply No 9

I 4

9 4

I I

14 4-I I

7.

Description of Work Replaced Fasteners on VHX-2 flange

8.

Tests conducted:

Hydrostatic l PneumatIcE Nominal Operating Pressure RI Exempt M Other n Pressure psi Test Temp.

Other n/a NOTE: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size Is 81 /2 In. x 11 in., (2)

Information in items 1 through 6 on this report is Included on each sheet, and (3) each sheet is numbered and number of sheets is recorded at the top of this form.

PALISADES NUCLEAR POWER PLANT FORM NIS-2 OWNER'S REPORT FOR REPAIR/ REPLACEMENT ACTIVITY ITEM F?

7

9. Remarks None CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authopization No.

N/A Expiration Date N/A Signed A

, ASME Program Engineer Date CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by HSB-CT of Connecticut have inspected the components described in this Owner's Report during the period April 18, 2003 to November 17.2004

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury of property damage or a loss of any kind arising from o with his inspection.

Commissions Ml 300762 Inspectors Signature National Board, Province and Endorsements Date WV4/UtY 1 i

_ or

I PALISADES NUCLEAR POWER PLANT FORM NIS-2 OWNER'S REPORT FOR REPAIR/ REPLACEMENT ACTIVITY ITEM

1. Owner Consumers Energy Company Date 1/19/2005 Name
2.

Plant Palisades Nuclear Power Plant Name 27780 Blue Star Highway, Covert, Ml 49043 Address Sheet 1

of 2

WO#24322358 Repair Organization P.O. No., Job No., etc

3. Work Performed by Owner Name Same Type Code Symbol Stamp Authorization Expiration Date Code Class Address
4.

Identification of System MSS

5.

(a) Applicable Construction Code ASME B31.1 N/A 1989 Edition Addenda n/a Code Case n/a (b) Applicable Edition of Section Xi Utilized for RepairlReplacement Activity 1989 With No Addenda (c) Applicable Section Xi Code Cases None

6.

Identification of Components ASME National Corrected, Code Name of Name of Manufacturer Board Other Year Removed, or Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Main Steam Crosby RV-0722 n/a PO#P804673 2004 Corrected No Safety Valve

7.

Description of Work Repaired Scratch from inlet flange on RV-0722

8.

Tests conducted:

Hydrostatic M PneumaticE Nominal Operating Pressure i

Exempt D Other 2 Pressure psi Test Temp.

0F Other NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1 /2 in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and number of sheets is recorded at the top of this form.

PALISADES NUCLEAR POWER PLANT FORM NIS-2 OWNER'S REPORT FOR REPAIR/ REPLACEMENT ACTIVITY ITEM 3

9. Remarks None CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section Xi.

Type Code Symbol Stamp NIA Certificate of Authqization No.

NIA Expiration Date N/A Signed

/1X 6

7 o

, ASME Progam Engineer Date 9

2,00 CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by HSB-CT of Connecticut have inspected the components described in this Owner's Report during the period April 18, 2003 to November 17.2004

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section Xi.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measure described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury of property damage or a loss of any kind arising from connected with this inspection.

Commissions Ml 300762 Inspectors Signature National Board, Province and Endorsements Date VAA4uARf`-' /?