ML043270498
| ML043270498 | |
| Person / Time | |
|---|---|
| Site: | Dresden, Quad Cities (DPR-019, DPR-025, DPR-029, DPR-030) |
| Issue date: | 12/03/2004 |
| From: | Rossbach L NRC/NRR/DLPM/LPD3 |
| To: | NRC/NRR/DLPM |
| Rossbach L, 415-2863, NRR/DLPM | |
| References | |
| TAC MC4397, TAC MC4398 | |
| Download: ML043270498 (6) | |
Text
1Note: As of the date of issuance of this summary, public access to ADAMS has been temporarily suspended so that security reviews of publicly available documents may be performed and potentially sensitive information removed. Please check the NRC Web site for updates of the resumption of ADAMS access.
December 3, 2004 LICENSEE:
Exelon Generation Company, LLC FACILITY:
Quad Cities and Dresden Nuclear Power Stations
SUBJECT:
SUMMARY
OF SEPTEMBER 23 and 24, 2004, MEETING WITH EXELON GENERATION COMPANY, LLC, ON EXELONS EVALUATION OF EXTENDED POWER UPRATE FLOW INDUCED VIBRATIONS (TAC NOS.
On September 23 and 24, 2004, a Category 1 public meeting was held between the U.S. Nuclear Regulatory Commission (NRC) and representatives of Exelon Generation Company, LLC, (Exelon) at Exelon Nuclear, Cantera Cornerstone 2, 4300 Winfield Road, Warrenville, Illinois. The purpose of the meeting was to discuss Exelons evaluation of the impact of flow induced vibrations (FIV) under extended power uprate (EPU) conditions on reactor pressure vessel internals, steam and feedwater systems and components at Quad Cities Nuclear Power Station (QCNPS), Units 1 and 2, and Dresden Nuclear Power Station (DNPS), Units 2 and 3. In its letter to NRC dated May 12, 2004, Exelon committed to hold this meeting as part of their actions to obtain approval from the NRC to return QCNPS, Units 1 and 2, to full licensed power. A list of meeting attendees is provided as Attachment 1.
The licensee presented an overview of their vibration evaluation for plant components known to be susceptible to EPU FIV, their vulnerability review for identifying other potential EPU vulnerabilities, the status of steam dryer load analysis, and the status of new steam dryers for QCNPS, including plans to instrument the new steam dryer at QCNPS, Unit 1. A copy of the licensees presentation is available in the Agencywide Documents Access and Management System at accession number ML0427302601.
Following Exelons presentations, the NRC staff discussed the licensees work in these areas with the responsible Exelon staff with supporting documentation available. The NRC staff also discussed with Exelon staff the failure of feedwater isokinetic probes at DNPS.
No decisions were made at this meeting. The NRC staff will continue its review of these activities after Exelon submits documentation of this work. Exelons May 12, 2004, letter to NRC, commits to submit documentation of the work described above and to have an additional meeting to discuss this work with NRC management. In addition, it was agreed to hold a meeting at Exelon on October 19, 2004, to discuss in more detail Exelons plans to instrument the new steam dryer at QCNPS, Unit 1.
Members of the public were in attendance. No public meeting feedback forms or comments were received.
Please direct any inquiries to Lawrence Rossbach at 301-425-2863, or lwr@nrc.gov.
Sincerely,
/RA/
Lawrence Rossbach Project Directorate III Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket Nos. 50-254, 50-265, 50-237, and 50-249 Attachments: 1. List of Attendees
- 2. Licensee Handout(s) (see ADAMS accession number ML042730260) cc w/atts: See next page Members of the public were in attendance. No public meeting feedback forms or comments were received.
Please direct any inquiries to Lawrence Rossbach at 301-425-2863, or lwr@nrc.gov.
Sincerely,
/RA/
Lawrence Rossbach Project Directorate III Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket Nos. 50-254, 50-265, 50-237, and 50-249 Attachments: 1. List of Attendees
- 2. Licensee Handout(s) (see ADAMS accession number ML042730260) cc w/atts: See next page DISTRIBUTION:
PUBLIC PDIII-2 r/f OGC ACRS/ACNW LRossbach TMarsh/JLyons WRuland GSuh PCoates TMensah EImbro DTerao TScarbrough JWu BElliot VThomas ASheikh SReynolds, RIII MRing, RIII MKurth, RIII MSheikh, RIII DHills, RIII DWeaver MBanerjee KManoly REnnis JStang GThomas DHelton ADAMS Accession Number: ML043270498(Letter)
ML042730264 (Package)
ML042730260 (Enclosure 2)
OFFICE PM:PDIII-2 LA:PDIII-2 SC:PDIII-2 NAME LRossbach PCoates GSuh DATE 11/23/04 11/23/04 12/3/04 OFFICIAL RECORD COPY
ENCLOSURE 1 ATTENDEES*
Meeting with Exelon Generation Company Evaluation of Extended Power Uprate Flow Induced Vibrations at Quad Cities and Dresden September 23 and 24, 2004 NRC G. Imbro S. Reynolds D. Terao M. Ring D. Hills L. Rossbach T. Scarbrough J. Wu B. Elliot V. Thomas A. Sheikh M. Kurth M. Sheikh Exelon J. Meister S. Eldridge M. Molaei L. Dyas K. Moser P. Simpson T. Roddey B. Kouba K. Jury D. Gullott C. Alguire S. Bolime J. Nosko G. DaBoo Other D. Tubbs C.F. Soltis K. Fujikawa K. OHara C. Settles
- Some part time
Dresden and Quad Cities Nuclear Power Stations cc:
Site Vice President - Dresden Nuclear Power Station Exelon Generation Company, LLC 6500 N. Dresden Road Morris, IL 60450-9765 Dresden Nuclear Power Station Plant Manager Exelon Generation Company, LLC 6500 N. Dresden Road Morris, IL 60450-9765 Regulatory Assurance Manager - Dresden Exelon Generation Company, LLC 6500 N. Dresden Road Morris, IL 60450-9765 U.S. Nuclear Regulatory Commission Dresden Resident Inspectors Office 6500 N. Dresden Road Morris, IL 60450-9766 Chairman Grundy County Board Administration Building 1320 Union Street Morris, IL 60450 Regional Administrator U.S. NRC, Region III 801 Warrenville Road Lisle, IL 60532-4351 Illinois Emergency Management Agency Division of Disaster Assistance &
Preparedness 110 East Adams Street Springfield, IL 62701-1109 Document Control Desk - Licensing Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Senior Vice President - Nuclear Services Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Vice President of Operations - Mid-West Boiling Water Reactors Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Vice President - Licensing and Regulatory Affairs Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Director - Licensing and Regulatory Affairs Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Associate General Counsel Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Manager Licensing - Dresden, Quad Cities and Clinton Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Site Vice President - Quad Cities Nuclear Power Station Exelon Generation Company, LLC 22710 206th Avenue N.
Cordova, IL 61242-9740 Quad Cities Nuclear Power Station Plant Manager Exelon Generation Company, LLC 22710 206th Avenue N.
Cordova, IL 61242-9740
Dresden and Quad Cities Nuclear Power Stations cc:
Regulatory Assurance Manager - Quad Cities Exelon Generation Company, LLC 22710 206th Avenue N.
Cordova, IL 61242-9740 Quad Cities Resident Inspectors Office U.S. Nuclear Regulatory Commission 22712 206th Avenue N.
Cordova, IL 61242 David C. Tubbs MidAmerican Energy Company One River Center Place 106 E. Second, P.O. Box 4350 Davenport, IA 52808-4350 Vice President - Law and Regulatory Affairs MidAmerican Energy Company One River Center Place 106 E. Second Street P.O. Box 4350 Davenport, IA 52808 Chairman Rock Island County Board of Supervisors 1504 3rd Avenue Rock Island County Office Bldg.
Rock Island, IL 61201