SOUTHERN CALIFORNIA An1 ESEUD I SO Nan An EDISON INTERNATIONAV& Company Dwight E. Nunn Vice President October 25, 2004 U. S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555

Subject:

Docket No. 50-362 Special Report: Inservice Inspection of Steam Generator Tubes, Cycle 13 San Onofre Nuclear Generating Station, Unit 3

Reference:

Steam Generator Program Guidelines, Nuclear Energy Institute Document Number NEI 97-06, Revision 1 Gentlemen:

On October 14, 2004, Southern California Edison (SCE) completed the inservice inspection of steam generator tubes at San Onofre Nuclear Generating Station Unit 3. The attached report is submitted in accordance with Technical Specification (TS) 5.7.2.c reporting requirements:

Report the number of tubes plugged in each steam generator within 15 days of completing the inspection; Report the complete results of steam generator tube inspections within 12 months of inspection completion.

The attachment to this letter, "Special Report: Inservice Inspection of Steam Generator Tubes," which was prepared in accordance with the referenced industry guidance, satisfies these reporting requirements. This report contains no new commitments.

Independent from the TS 5.7.2.c reporting requirements, this report also incorporates results of a secondary side inspection of eggcrate tube supports using remote video equipment.

If you require any additional information, please advise.

Sincerely, Attachments cc:

B. S. Mallett, NRC Regional Administrator, Region IV B. M. Pham, NRC Project Manager, San Onofre Units 2 & 3 C. C. Osterholtz, NRC Senior Resident Inspector, San Onofre Units 2 & 3 Institute of Nuclear Power Operations (INPO)

P.O. Box 128 San Clemente. CA 92674.0128 949-368-1480 Fax 949-368-1490

'1.M

Inservice Inspection of Steam Generator Tubes Special Report Attachment Page 1 of 11 SPECIAL REPORT: INSERVICE INSPECTION OF STEAM GENERATOR TUBES Regulatory Reporting Requirements Reporting Requirement 5.7.2.c of Appendix A, Technical Specification to Facility Operating License NPF-15, requires the number of tubes plugged and tubes sleeved in each steam generator to be reported to the Nuclear Regulatory Commission within 15 days following completion of the inspection.

Reporting Requirement 5.7.2.c of Appendix A, Technical Specification to Facility Operating License NPF-15, requires the complete results of steam generator tube inservice inspection to be reported to the Nuclear Regulatory Commission within 12 months following completion of the inspection.

Inspection Scope Tables 1 and 2 summarize the inspection scope. Also, when indications by the bobbin probe were non-quantifiable or distorted, the inspection program included inspection with the Plus-Point Probe. Table 3 provides the list of Nondestructive Examination (NDE) techniques utilized for each degradation mechanism.

Inspection Scope Expansion Row 3 of Tables 1 and 2 shows the only significant inspection program scope expansion in response to inspection results. In response to one indication, the planned cold leg top-of-tubesheet rotating plus point probe inspection (30% in SG E-088 and 29% in SG E-089) was expanded to 100% in both steam generators. No indications were detected in this expanded scope inspection. Additional Information on this expansion response follows.

One circumferential indication was detected at the cold leg top-of-tubesheet in Steam Generator E-089 during planned rotating plus point probe inspection. That indication, in Tube Row 51 Column 129 at TSC + 0.06 inches, had an amplitude of 0.14 volts and a phase angle indicative of outside diameter initiation. The indication's rotating plus point probe data was used to produce the following size information. The indication's maximum depth was 39% and the length was 0.24 inches (approximately 37 degrees of the 360 degree circumference of the tube).

Results This report satisfies the listed regulatory reporting requirements.

Table 4 summarizes the number of tubes repaired and active degradation mechanisms found. Each tube is only counted once in this listing, although it may also have an eddy current indication of a type below the point in the listing where it appears. The Appendices provide the complete results of the steam generator tubing inservice inspection.

Condition Monitoring was performed on all rotating plus point probe indications using established criteria. All indications were within the criteria acceptance range. Thus, there was no insitu pressure or leak testing of tubing. Condition Monitoring results provide assurance that performance criteria in the NEI guidance (structural integrity and accident-induced leakage) were met during operation prior to this inspection.

Inservice Inspection of Steam Generator Tubes Special Report Attachment Page 2 of 11 Results of Secondary Side Inspection (SSI) of Eggcrate Tube Supports Visual inspections of the steam generator tube lattice supports for both steam generators at SONGS Unit 3 were completed using remote video equipment. The Unit 3 Cycle 13 (U3C13) inspection encompassed 17 camera drops on each of the two steam generators. These inspections were conducted from the fifth to the tenth or uppermost lattice support structure.

The results indicate no evidence of ongoing Flow Accelerated Corrosion (FAC). These results are similar to the last lattice inspection on Unit 3 conducted in the Cycle 11 refueling outage. Using the conservative plugging criteria developed from the initial FAC discovery, no tubes were plugged.

Repair of Tubes Tables 5 and 6 list the tubes repaired by plugging for each steam generator. Although approved for use, sleeves have not been used to date in Unit 3.

Table 5 provides an itemized listing of the tubes plugged in steam generator E-088 along with the corresponding Table 4 category specifying the indication orientation/location.

Table 6 provides an itemized listing of the tubes plugged in steam generator E-089 along with the corresponding Table 4 category specifying the indication orientation/location.

Repair Methods, Number of Tubes Repaired and Effective Plugging Percentage All tube plugging was performed using the design, materials, and installation methods of AREVA. A "roll" method was used for all tube plugs. Three tubes in Steam Generator E-088 and five tubes in Steam Generator E-089 were "stabilized" in the vicinity of the top of the tubesheet using the design, materials, and installation methods of AREVA.

46 tubes were plugged in Steam Generator E-088 during the Cycle 13 refueling outage. A total of 704 tubes have been plugged. No tubes have ever been sleeved in this steam generator. The design number of tubes is 9350 tubes. The effective plugging percentage for E-088 is 7.6%.

62 tubes were plugged in Steam Generator E-089 during the Cycle 13 refueling outage. A total of 651 tubes have been plugged. No tubes have ever been sleeved in this steam generator. The design number of tubes is 9350 tubes. The effective plugging percentage for E-089 is 7.0%.

Inservice Inspection of Steam Generator Tubes Attachment Description of Tables and Appendices Special Report Page 3 of 11 Table 1 -

Table 2 -

Table 3-Table 4 -

Table 5 -

Table 6-Appendix 1 -

Appendix 2 -

Appendix 3-Appendix 4 -

Summary of the Inspection Scope for Steam Generator E-088 for the U3C13 Refueling Outage Summary of the Inspection Scope for Steam Generator E-089 for the U3C1 3 Refueling Outage List of Nondestructive Examination (NDE) Techniques Utilized for Each Degradation Mechanism for the U3C13 Refueling Outage Number of Tubes Repaired and Active Degradation Mechanisms Found During the U3C13 Refueling Outage U3C13 Refueling Outage Tubes Plugged, Steam Generator E-088 U3C13 Refueling Outage Tubes Plugged, Steam Generator E-089 Steam Generator Reference Information Legend for Appendices 3 and 4 Inspection Summary, Steam Generator E-088 Inspection Summary, Steam Generator E-089

Inservice Inspection of Steam Generator Tubes Attachment Special Report Page4of 11 TABLE 1 - Summary of the Inspection Scope for Steam Generator E-088 for the U3C13 Refueling Outage Number of Tubes / % of Tubes Inspection Scope Item In Steam Generator E-088 Planned Actual Full length of tube with the Bobbin Probe (excluding U-8692/ 100%

8692/ 100%

bends for Rows 1-3)

Hot leg top-of-tubesheet with the Plus-Point Probe (to 16 8692/ 100%

8692/ 100%

inches below the expansion transition)

Cold leg top-of-tubesheet with the Plus-Point Probe 2623 /30%

8692/ 100%

U-bend regions of Rows 1, 2, and 3 with both mid and high 184/100%

184/100%

frequency Plus-Point Probes U-bend regions of Rows 4 through 10 with mid-frequency 432/100%

432/100%

Plus-Point Probes Plus-Point Probe examinations of tube support All / 100%

298/100%

intersections with dents greater than, or equal to, 2 volts Plus-Point Probe examinations of dings greater than, or All / 100%

305 / 100%

equal to, 4 volts Plus-Point Probe examination of all tube support intersections with quantified wear indications by the bobbin All / 100%

843 /100%

probe Plus-Point Probe examinations of hot leg scallop bar supports with the above adjacent hot leg square bend and 75/20%

75/20%

the below one support elevation of tubing freespan

Inservice Inspection of Steam Generator Tubes Attachment Special Report Page 5 of 11 TABLE 2 - Summary of the Inspection Scope for Steam Generator E-089 for the U3C13 Refueling Outage Number of Tubes / % of Tubes Inspection Scope Item In Steam Generator E-089 Planned Actual Full length of tube with the Bobbin Probe (excluding U-8761 / 100%

8761 /100%

bends for Rows 1-3)

Hot leg top-of-tubesheet with the Plus-Point Probe (to 16 8761 /100%

8761 /100%

inches below the expansion transition)

Cold leg top-of-tubesheet with the Plus-Point Probe 2610/29%

8761 /100%

U-bend regions of Rows 1, 2, and 3 with both mid and high 174/100%

174 /100%

frequency Plus-Point Probes U-bend regions of Rows 4 through 10 with mid-frequency 449 /100%

449 /100%

Plus-Point Probes Plus-Point Probe examinations of tube support All / 100%

327/100%

intersections with dents greater than, or equal to, 2 volts Plus-Point Probe examinations of dings greater than, or All / 100%

400 / 100%

equal to, 4 volts Plus-Point Probe examination of all tube support intersections with quantified wear indications by the bobbin All / 100%

592 / 100%

probe Plus-Point Probe examinations of hot leg scallop bar supports with the above adjacent hot leg square bend and 73 /20%

73/20%

the below one support elevation of tubing freespan

Inservice Inspection of Steam Generator Tubes Attachment Special Report Page 6of 11 TABLE 3 - List of Nondestructive Examination (NDE) Techniques Utilized for Each Degradation Mechanism for the U3C13 Refueling Outage Table 5 Indication Orientation / Location Probe Type for Probe Type for Category Detection Characterization Circumferentially oriented ID indications near 1

the expansion transition at the top of the hot Plus Point Plus Point leg tubesheet Circumferentially oriented OD indications 2, 3 near the expansion transition at the top of the Plus Point Plus Point hot or cold leg tubesheet Axially oriented ID indications below the 4

expansion transition at the top of the hot leg Bobbin Plus Point tubesheet Circumferentially oriented ID indications 5

below the expansion transition at the top of Plus Point Plus Point the hot leg tubesheet 6

Indications of wear at tube support locations Bobbin Plus Point 7, 8 Volumetric indications Bobbin or Plus Plus Point Point 9Miscellaneous preventative plugging Pobinto ls Pu on

Inservice Inspection of Steam Generator Tubes Attachment Special Report Page7of 11 TABLE 4 - Number of Tubes Repaired and Active Degradation Mechanisms Found During the U3C13 Refueling Outage Category Indication Orientation / Location SG E-088 SG E-089 Tubes with circumferentially oriented ID indications near the 1

expansion transition at the top of the hot leg tubesheet. (ID 3

3 Circ @ TSH)

Tubes with circumferentially oriented OD indications near 2

the expansion transition at the top of the hot leg tubesheet.

0 1

(OD Circ @ TSH)

Tubes with circumferentially oriented OD indications near 3

the expansion transition at the top of the cold leg tubesheet.

0 1

(OD Circ @ TSC) 4 Tubes with axially oriented ID indications below the inlet 1

6 top-of-tubesheet. (ID Axial below TSH)

Tubes with circumferentially oriented ID indications below 6

2 the inlet top-of-tubesheet. (ID Circ below TSH) 6 Tubes with indications of wear at tube support locations.

36 45 (Wear @ Support)

Tubes with apparent previous loose part wear (not an active 2

degradation mechanism). (OD Vol @ TSH) 8 Tubes with miscellaneous volumetric indications (not an 0

1 active degradation mechanism). (OD Vol @ Miscellaneous) 9 Tubes with Data Quality/ALARA complications (Data 0

1 Quality © Miscellaneous)

Total 46 62

Inservice Inspection of Steam Generator Tubes Attachment Special Report Page 8 of 11 TABLE 5 - SONGS U3C13 Refueling Outage Tubes Plugged STEAM GENERATOR E-088 Row Column Reason for Plugging Tube (per Table 4) 78 26 Wear @ Support 8

38 ID Circ @ TSH 10 56 ID Circ @ TSH 57 67 ID Circ below TSH 40 68 Wear @ Support 139 69 Wear @ Support 46 78 Wear @ Support 48 80 Wear @ Support 53 83 Wear @ Support 58 84 Wear @ Support 53 85 Wear @ Support 55 85 Wear @ Support 67 89 Wear @ Support 69 89 Wear @ Support 60 90 Wear @ Support 53 91 Wear @ Support 55 91 Wear @ Support 69 91 Wear @ Support 57 93 Wear @ Support 68 94 Wear @ Support 62 96 Wear @ Support 146 96 Wear @ Support 55 97 Wear @ Support 52 98 Wear @ Support 54 98 Wear @ Support 145 99 Wear @ Support 44 100 Wear @ Support 50 100 Wear @ Support 47 101 Wear @ Support 47 103 Wear @ Support 131 103 Wear @ Support 81 111 Wear @ Support 18 112 ID Axial below TSH

Inservice Inspection of Steam Generator Tubes Attachment Special Report Page9of 11 TABLE 5 (CONT.) - SONGS U3C13 Refueling Outage Tubes Plugged STEAM GENERATOR E-088 Row Column Reason for Plugging Tube (per Table 4) 48 112 Wear @ Support 47 113 Wear@Support 81 113 Wear @ Support 10 114 ID Circ below TSH 11 125 ID Circ below TSH 11 127 ID Circ @ TSH 48 128 Wear @ Support 8

132 ID Circ below TSH 11 139 ID Circ below TSH 80 140 Wear @ Support 11 149 ID Circ below TSH 54 156 Wear @ Support 14 174 Wear @ Support

Inservice Inspection of Steam Generator Tubes Attachment Special Report Page 10 of 11 TABLE 6 - SONGS U3C13 Refueling Outage Tubes Plugged STEAM GENERATOR E-089 Row Column Reason for Plugging Tube (per Table 4) 27 3

OD Vol TSH 29 3

ODVol@TSH 65 27 Wear @ Support 46 36 Wear @ Support 38 40 Wear @ Support 27 47 ID Circ @ TSH 33 55 Wear @ Support 66 60 Wear @ Support 78 60 OD Vol a Miscellaneous 27 61 ID Axial below TSH 31 63 ID Circ below TSH 9

65 Data Quality @ Miscellaneous 31 65 ID Axial below TSH 31 67 ID Axial below TSH 111 67 ID Circ below TSH 33 71 Wear @ Support 35 71 Wear @ Support 39 73 Wear @ Support 47 73 Wear @ Support 49 77 Wear @ Support 56 80 Wear @ Support 128 80 Wear @ Support 53 81 Wear @ Support 59 81 Wear @ Support 63 81 Wear @ Support 56 82 Wear @ Support 64 82 Wear @ Support 63 83 Wear @ Support 101 83 ID Circ @ TSH 55 85 Wear @ Support 61 85 Wear @ Support 58 86 Wear @ Support 62 88 Wear @ Support 55 89 Wear @ Support 58 90 Wear @ Support

Inservice Inspection of Steam Generator Tubes Attachment Special Report Page 11 of 11 TABLE 6 (CONT.) - SONGS U3C13 Refueling Outage Tubes Plugged STEAM GENERATOR E-089 Row Column Reason for Plugging Tube (per Table 4) 65 91 Wear @ Support 145 91 Wear @ Support 51 93 Wear @ Support 146 94 Wear @ Support 61 95 Wear @ Support 51 101 Wear @ Support 145 101 Wear @ Support 144 106 Wear @ Support 31 107 ID Axial below TSH 37 107 Wear @ Support 40 110 Wear @ Support 47 111 Wear @ Support 50 114 Wear @ Support 27 115 ID Axial below TSH 102 118 ID Axial below TSH 60 122 OD Circ@ TSH 57 123 Wear @ Support 110 124 Wear @ Support 79 125 Wear @ Support 51 129 OD Circ @ TSC 79 129 Wear @ Support 45 131 Wear @ Support 47 133 Wear @ Support 106 142 Wear @ Support 43 145 Wear C Support 30 146 ID Circ @ TSH 78 160 Wear © Support

Inservice Inspection of Steam Generator Tubes Attachment Special Report Page 1 of 4 Appendix 1 Steam Generator Reference Information

Inservice Inspection of Steam Generator Tubes Special Report Attachment Page 2 of 4 Steam Generator CE Model 3410 Tube Support Drawing 15 iri~1 r

4 Vs )

M C

N l

10H; 1{ cc 3l.75_

09H 09C 30.75' 08H 08C W

AS I30.75 07H

=

07C 06K H-C 05H

-050 04H

=04C 03H 03C 02H

=

20 35.

01H-010 27.25' TSH TSC 23' TEH rrTEC

Inservice Inspection of Steam Generator Tubes Attachment Special Report Page 3 of 4 STEAM GENERATOR TUBE SUPPORT INTERSECTIONS ABOVE THE 7 T11 (FULL) EGGCRATE SUPPORT SUPPORT INTERSECTIONS ROW STRUCTURES 122-147 08H 09H 10Hl DBH VHI VH2 VH3 VSM I VC3 VC2 VCI DBC OGC 09C 08C 120-121*

08H 09H 10H DBH VHI VH2 VH3 VSM VC3 VC2 VCI DBC IOC 09C 08C 115-119 08H 09H

=

DBH VHI VH2 VH3 VSM VC3 VC2 VC1 DBC 09C 08C 86-114 08H 09H DBH VH2 VH3 VSM VC3 VC2 DBC 09C 08C 84-85*

08H 09HFf DBH VH2 VH3 VSM VC3 VC2 DBC 09C 08C 83 08H DBH VH2 VH3 VSM VC3 VC2 DBC 08C 51-82 08H

=

DBH VH3 VSM VC3 DBC

=

08C 49-50*

08H DBH VSM DBC 08C 19-48 DBH VSM DBC 1-18 DBH

=

DBC

  • Indicates those rows adjacent to scallop bars

Inservice Inspection of Steam Generator Tubes Attachment Special Report Page 4 of 4 SOUTHERN CALIFORNIA EDISON, SAN ONOFRE CE MODEL 3410 STEAM GENERATOR 1S

?a 3*

do so go 70 Do 100 110 120 110 140 150 ICO 170 I

4*)

130 I

I

-I ;

I 0

o 6 a

I 'L R

iI!

P!

-4 170 110 100 70

£0 50 40 10 20 10 g ~

0 0 0 0 0~og

~ % %

~ '

o g g o o g. ~00 0 o2

% 0 0o %

0 0

_ Q Q 0 0 0 0 0

0 0 0 0 0 0 O Q~

~

0 0 O

o g g o 0g g o o g go0 0 0 0 0 00 0 0 0 g 0 g o g g g g g g

0 g 0

0gg 0o o o g g g g 0 0<0 O o o O o o o%0~%

0 0 0

O%0 000 0

A 5 0 0 0 4

, 0 ~ ~ ~

O 0 0 0 ~ 2 0 0 2 0 2 2 000 0

0

0 0 g o g 0 0 o ~ o ~ ~

0 0 0 0 0 0 0 0 000 60 0 0 0 O 0 o o0~

o o 0

~ 0 %OoR o ID V0 0

0" 000

~0 0 0~ o o o 0 0 0 0 0 0

0~t~

0o g o o o o g g g g g g g g g 0 g g g g g g g g o o o g gg0 o o o o ~ o o DOo oOo""

`o "I"

-.012 o

." 0o 1

110 I,,

110 oo

-590

-so

-770

-So

-so

,40

-tg, 0

1 65 0g

0o6 og61 o5 gojgggo q 0

g 0 g 0 g 6

jg-,

- o0.

90 1 o 9 3-9 0 cooV 2 a 2 9 60 0.0000 06'0'H 0.3' g

-i-~

v v~v~ ~oO 000 o° o~o o~o Ao °o o~o io SO O vi ODO OOO lOO

§ 0 0o

°0°°o o gg0 g gg0 0 0 0 0 3 0 0 0 0 0 0 0 0 0 0 0 3 g g g S

>~~o g ~ o o o o o o o o g g ~ 02 g g~

0 0 0 0 0 0

0 0

0 0 0

0, 0 00 0o 00 0 0 0 0

0

.80ggf 0o 0 0 v 'J 0v ~

0V 0 0 ro o9oo

~ ~ o o o o o o o

& ~

4 t

~ ~ ~ o 0

0 0 ~ 0 0 0 0 0 0 ~ j 2 a ~ 9 -_

_00 0

0 0

000 0

~

~

? ~ ? 2

ggC,

~ ~ s s s 0 0 0 00 og g go o og go o o og g 0O % 0 0 6g g g ggO g g g

g g 0~~~

g0ggggggg 00 00 0 0 0 0 0

o o o o g o o o g o o o g g 0 0 0 0 0 0 0 0 1oo100

% % % O % 0 0

0 0 0 0 ~

0 o

o n

a Y

Y y

y o y Y o0Yr Y o o A

  • 3 g g g0.o..

0...

900.0,2110, W0V U V 00 10 0

30 40 50 to

?O so 40 se CCI 00g0g

'O 7

0 3

5 0

0000og 00 0°o~o ggogogogo t° 4 ° gg gg f g o~g W ~vgg° 10 110 10 1I0 140 150 0

170 go 70 so so

Inservice Inspection of Steam Generator Tubes Attachment Special Report Page 1 of 2 Appendix 2 Legend for Appendices 3 and 4

Inservice Inspection of Steam Generator Tubes Attachment Special Report Page 2 of 2 List of Abbreviations and Format Used to Describe Indications from Rotating Probe Testing "I-Code" Abbreviations Explanation of the Abbreviations SCI Single Circumferential Indication MCI Multiple Circumferential Indications SAI Single Axial Indication MAI Multiple Axial Indications MMI Mixed Mode Indications SVI Single Volumetric Indication (i.e. no special axial or circumferential aspect)

MVI Multiple Volumetric Indications (i.e. no special axial or circumferential aspect)

Format In Appendices 3 and 4, a single line of data is associated with each individual rotating probe indication. Below is a descriptive example of the format.

ROW UNE VOLTS DEG CHN IND

%TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL #

LEG PROBE 4

1 VOLTS EG C

CODE LOCATION EXT EXT INCHES INCHES HOT CODE COLD

1. All I-Code" indications require a single line entry. The example above displays the form of a Resolution Report line. The VOLTS field contains the Plus-Point P-to-P voltage of the largest, most representative response. The DEG field contains the corresponding phase angle. The CHN field contains the reporting channel (i.e. the appropriate 300kHz Plus-Point channel). The IND field contains the appropriate 3-letter code (see list above). The %TW field indicates the percent wall loss for wear indications. The LOCATION field contains the abbreviation for the referenced landmark and the (FROM-TO) distance for the indication. The EXT fields contain the landmarks of the beginning and end of the test extent. The UTIL 1 field contains the axial or circumferential length. The UTIL 2 field was used to document the actual inspection distance below the hot leg top-of-tubesheet for applicable inspections. The CAL # field identifies the sequence number of the Calibration Group to obtain the data. The LEG field indicates the leg the probe originated from. The PROBE field contains the abbreviated identification of the type of probe used. Exceptions to this general guidance are provided in paragraphs 2 and 3 below.
2.

For axial indications of extended length, the location should be ranged (FROM-TO) in the LOCATION field. If the range of such an indication includes any part of a support structure, it should be referenced from that landmark.

3.

Some data lines contain a note abbreviation in the UTIL 1 or UTIL 2 column. These are the definitions of common abbreviations:

LAR: Lead Analyst Reviewed LOCOK: Location Verification IDOK: Tube ID Verification HR: INF (indication not found) is reported and tube encode is correct

Inservice Inspection of Steam Generator Tubes Attachment Special Report Appendix 3 Inspection Summary Steam Generator E-088

Framatome ANP Inc.

Customer Name: SONGS Unit 3 10/14/04 11:58:34 Component: S/G 88 Page 1 of 28 Query Name : rpcicodes and 0-100%twd.qry Query

Title:

MAI, MCI, MMI, MVI, SAI, SCI, SVI, 0-100% TWD Selected Outages/Scopes3:10/04 R 10/04 R 10/04 R 10/04 R 10/04 R 10/04 R 10/04 R 10/04 R 10/04 R 10/04 R 10/04 R 10/04 R 10/04 R F013 F013 F013 F013 F013 F013 F013 F013 F013 F013 F013 F013 F013 Out of Scope BOBBIN RPC TSH RPC TSC +1/-i RPC TSC +3/-1 RPC UBENDS R1-3 RPC UBENDS R4-10 RPC 20% H/L SCALLOP BARS H/L SPECIAL INTEREST C/L SPECIAL INTEREST UBEND SPECIAL INTEREST Special Retest with RPC PLP and Boundings Input Selected

All Tubes Output File Selected :

Selected Indications : MAI,MCI,MMI,MVI,SAI,SCI,SVI,TWD, Selected Probes

ALL Selected Channels
ALL Selected Cals
ALL Selected Extentl
ALL Selected Extent2
ALL Selected Util 1 Selected Util 2 Selected Tube Heat TWD Range Volts Range Degrees Range Radius from Center Range Location Range Inspection Leg Queried : BOTH Include In-Service or Out-Service Tubes : In-Service only Advanced User Query :

I

I Framatome ANP Inc.

10/14/04 11:58:34 Customer Name: SONGS Unit 3 Component: S/G 88 Page 2 of 28 MAI, MCI, MMI, MVI, SAI, SCI, SVI, 0-100% TWD QUERY: rpc icodes and 0-100%twd ROW LINE VOLTS DEG CHN IND STW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 7

1 0.27 45 P 3 TWD 11 DBC

+1.06 TEC TEH 38 HOT 600UL 16 2

0.34 76 P 2 TWD 14 05H

-0.57 TEC TEH 49 HOT 600UL 43 5

0.48 102 P 2 TWD 21 04C

-0.14 TEC TEH 3

HOT 600UL 33 7

0.22 121 P 2 TWD 11 VSM

-0.92 TEC TEH 3

HOT 600UL 35 7

0.32 53 P 2 TWD 12 VSM

-0.88 TEC TEH 4

HOT 600UL 49 7

0.18 117 P 2 TWD 10 06H

-1.12 TEC TEH 3

HOT 600UL 43 9

0.16 143 P 2 TWD 9 VSM

-0.86 TEC TEH 3

HOT 600UL 67 11 0.33 133 P 2 TWD 16 VH3

-0.78 TEC TEH 3

HOT 600UL 29 13 0.30 87 P 3 TWD 15 DBH

+1.25 TEC TEH 3

HOT 600UL 43 13 0.39 137 P 2 TWD 15 VSM

-0.78 TEC TEH 4

HOT 600UL 66 14 0.23 129 P 2 TWD 12 04C

-0.20 TEC TEH 3

HOT 600UL 68 14 0.52 123 P 2 TWD 20 VH3

-0.95 TEC TEH 4

HOT 600UL 70 14 0.49 135 P 2 TWD 22 VH3

+0.00 TEC TEH 3

HOT 600UL 72 14 0.29 71 P 3 TWD 16 DBC

-1.73 TEC TEH 3

HOT 600UL 69 15 0.32 150 P 2 TWD 16 VH3

-0.76 TEC TEH 3

HOT 600UL 71 15 0.19 68 P 2 TWD 8 VH3

-0.73 TEC TEH 4

HOT 600UL 0.18 85 P 2 TWD 8 VSM

-1.02 TEC TEH 4

HOT 600UL 75 15 0.09 26 P 3 TWD 4 DBC

-1.85 TEC TEH 4

HOT 600UL 0.14 192 P 3 TWD 7 DBC

+2.12 TEC TEH 4

HOT 600UL 77 15 0.25 99 P 3 TWO 14 DBC

-1.81 TEC TEH 3

HOT 600UL 51 17 0.23 129 P 2 TWD 13 VH3

+0.74 TEC TEH 7

HOT 600UL 22 18 0.29 43 P 2 TWD 15 VSM

-0.82 TEC TEH 7

HOT 600UL 67 19 0.27 89 P 2 TWD 15 VH3

-0.98 TEC TEH 7

HOT 600UL 83 19 0.36 99 P 2 TWD 15 VH2

+0.89 TEC TEH 24 HOT 600UL 74 20 0.19 173 P 3 TWO 11 DBH

+1.91 TEC TEH 7

HOT 600UL 78 20 0.35 85 P 3 TWO 17 DBH

+1.73 TEC TEH 7

HOT 600UL 82 20 0.17 30 P 3 TWD 8 DBC

+2.03 TEC TEH 24 HOT 600UL 43 21 0.27 101 P 2 TWD 15 VSM

+0.59 TEC TEH 7

HOT 600UL 79 21 0.22 128 P 3 TWO 12 DBC

+1.81 TEC TEH 7

HOT 600UL 0.52 110 P 3 TWD 24 DBH

+1.63 TEC TEH 7

HOT 600UL 80 22 0.21 75 P 3 TWD 12 DBH

+1.91 TEC TEH 7

HOT 600UL 82 22 0.30 61 P 3 TWO 13 DBC

+1.75 TEC TEH 24 HOT 600UL 71 23 0.20 52 P 3 TWD 11 DBH

+1.67 TEC TEH 7

HOT 600UL 56 24 0.15 67 P 3 TWD 8 DBH

+1.47 TEC TEH 8

HOT 600UL 98 24 0.23 154 P 2 TWD 11 06C

+0.89 TEC TEH 23 HOT 600UL 0.16 50 P 2 TWD 8 06C

+0.06 TEC TEH 23 HOT 600UL 91 25 0.22 158 P 2 TWD 9 VH2

+0.82 TEC TEH 24 HOT 600UL 78 26 0.94 67 P 2 TWO 31 VC3

+0.99 TEC TEH 11 HOT 600UL 0.40 84 P 2 TWD 18 VC3

-0.74 TEC TEH 11 HOT 600UL 77 27 0.26 15 P 3 TWD 12 DEC

+1.53 TEC TEH 49 HOT 600UL 76 28 0.16 40 P 3 TWD 8 DBC

+1.83 TEC TEH 54 HOT 600UL

Framatome ANP Inc.

10/14/04 11:58:34 Customer Name: SONGS Unit 3 Component: S/G 88 Page 3 of 28 MAI, MCI, MMI, MVI, SAI, SCI, SVI, 0-100% TWD QUERY: rpcicodes and 0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL i LEG PROBE 82 28 0.27 71 P 3 TWD 12 DBH

-1.75 TEC TEH 24 HOT 600UL 94 28 0.47 71 P 2 TWD 19 VSM

-0.76 TEC TEH 24 HOT 600UL 0.35 100 P 2 TWD 14 VH2

-1.09 TEC TEH 24 HOT 600UL 0.28 66 P 2 TWD 12 VH3

+0.82 TEC TEH 24 HOT 600UL 98 28 0.16 48 P 3 TWD 7 DBH

-2.00 TEC TEH 24 HOT 600UL 102 28 0.29 97 P 2 TWD 13 VH2

+0.86 TEC TEH 24 HOT 600UL 77 29 0.26 146 P 2 TWD 12 VC3

-0.75 TEC TEH 54 HOT 600UL 0.24 108 P 3 TWD 11 DBC

-1.86 TEC TEH 54 HOT 600UL 79 29 0.30 123 P 2 TWD 14 VC3

-0.85 TEC TEH 11 HOT 600UL 0.18 156 P 3 TWD 10 DBH

+1.47 TEC TEH 11 HOT 600UL 89 29 0.30 116 P 2 TWD 13 VH2

+0.93 TEC TEH 24 HOT 600UL 0.48 102 P 2 TWD 19 VH2

-0.05 TEC TEH 24 HOT 60OUL 99 29 0.28 123 P 3 TWD 13 DBH

+1.68 TEC TEH 23 HOT 600UL 107 29 0.20 153 P 2 TWD 9 VH2

-0.62 TEC TEH 23 HOT 600UL 60 30 0.35 116 P 2 TWD 15 VH3

-0.82 TEC TEH 54 HOT 600UL 78 30 0.75 110 P 2 TWD 28 VSM

+0.79 TEC TEH 11 HOT 600UL 0.26 25 P 2 TWD 13 VSM

+0.08 TEC TEH 11 HOT 600UL 0.41 50 P 2 TWD 18 VH3

+0.69 TEC TEH 11 HOT 600UL 0.33 150 P 2 TWD 15 VH3

-0.62 TEC TEH 11 HOT 600UL 102 30 0.39 78 P 2 TWD 17 08C

-1.00 TEC TEH 23 HOT 600UL 0.18 55 P 2 TWD 7 08C

+0.00 TEC TEH 23 HOT 600UL 73 31 0.35 130 P 2 TWD 15 VH3

+0.89 TEC TEH 54 HOT 600UL 75 31 0.21 148 P 3 TWO 12 DBC

+1.75 TEC TEH 11 HOT 600UL 0.22 101 P 2 TWD 11 VH3

+0.83 TEC TEH 11 HOT 600UL 77 31 0.30 128 P 2 TWD 13 VC3

+0.93 TEC TEH 54 HOT 600UL 0.53 125 P 2 TWD 20 VSM

+0.97 TEC TEH 54 HOT 600UL 0.57 139 P 3 TWD 22 DBH

+1.77 TEC TEH 54 HOT 600UL 107 31 0.31 46 P 2 TWD 14 VH2

-0.95 TEC TEH 24 HOT 600UL 109 31 0.22 39 P 3 TWD 10 DBC

-1.80 TEC TEH 23 HOT 600UL 74 32 0.30 19 P 3 TWD 17 DBH

+1.34 TEC TEH 15 HOT 600UL 76 32 0.50 34 P 3 TWD 20 DBH

+1.75 TEC TEH 16 HOT 600UL 110 32 0.34 114 P 2 TWD 15 02H

-0.89 TEC TEH 24 HOT 600UL 73 33 0.27 154 P 2 TWD 12 VH3

+0.72 TEC TEH 16 HOT 600UL 0.48 112 P 3 TWD 19 DBH

+1.48 TEC TEH 16 HOT 600UL 75 33 0.29 34 P 3 TWD 17 DBC

-1.92 TEC TEH 15 HOT 600UL 0.27 130 P 2 TWD 14 VC3

+0.81 TEC TEH 15 HOT 600UL 81 33 0.32 148 P 2 TWD 14 VSM

-0.92 TEC TEH 23 HOT 600UL 0.63 133 P 2 TWD 24 VH3

+0.80 TEC TEH 23 HOT 600UL 0.40 49 P 2 TWD 18 VH3

+0.06 TEC TEH 23 HOT 600UL 103__3 ___0.35__ 97__ P_ 2_ TWO__15_____

+0.73-------------

TEC--------TEH ---------

24------- HOT----------------------

103 33 0.35 97 P 2 TWD 15 VH2

+0.73 TEC TEH 24 HOT 600UL 111 33 0.36 98 P 2 TWD 15 VH2

-0.96 TEC TEH 24 HOT 600UL 56 34 0.44 123 P 2 TWD 18 VH3

-0.89 TEC TEH 16 HOT 600UL 74_____34____0.33______32____P___3___TWO_____18____DE______+___.37_____TEC_____T___E___15____HOT_______________

72 34 0.51 110 P 2 TWD 20 VSM

-0.89 TEC TEH 16 HOT 600UL 74 34 0.33 32 P 3 TWD 18 DBH

+1.37 TEC TEH 15 HOT 600UL 76 34 0.54 103 P 2 TWD 21 VH3

+0.84 TEC TEH 16 HOT 600UL 0.18 150 P 3 TWD 9 DBC

+1.95 TEC TEH 16 HOT 600UL 0.22 41 P 3 TWD 10 DBH

+1.55 TEC TEH 16 HOT 600UL

Framatome ANP Inc.

10/14/04 11:58:34 Customer Name: SONGS Unit 3 Component: S/G 88 Page 4 of 28 MAI, MCI, MMI, MVI, SAI, SCI, SVI, 0-100% TWD QUERY: rpc_icodes and 0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 114 34 0.38 75 P 3 TWD 15 DBC

+1.86 TEC TEH 24 HOT 600UL 63__35__ 0.21_ __68_ P__3_T_ _O __13 _DBH __- 1.83_TECTE__ -

____--- ____---_____________________OT____

=--------------

63 35 0.21 68 P 3 TWD 13 DBH

-1.46 TEC TEH 15 HOT 600UL 75 35 0.12 146 P 3 TWD 8 DBC

-1.46 TEC TEH 15 HOT 600UL 81 35 0.15 34 P 3 TWD 6 DBC

-1.60 TEC TEH 23 HOT 600UL 111 35 0.69 97 P 2 TWD 24 VH2

-0.96 TEC TEH 24 HOT 600UL 76 36 0.40 132 P 2 TWD 17 VH3

-0.15 TEC TEH 16 HOT 600UL 0.56 120 P 2 TWD 21 VH3

-0.64 TEC TEH 16 HOT 600UL 0.32 107 P 3 TWD 14 DBC

+2.17 TEC TEH 16 HOT 600UL 75 37 0.14 163 P 3 TWD 9 DBC

+1.76 TEC TEH 15 HOT 600UL 109 37 0.14 152 P 3 TWD 6 DBC

+2.15 TEC TEH 23 HOT 600UL 111_ 37_ 0.43_ 119 P=2 TWO_

0.93-------T---

C---T_____

24------------------

HOT-----=

111 37 0.43 119 P 2 TWD 17 VH2

-0.93 TEC TEH 24 HOT 600UL 113 37 0.27 143 P 2 TWD 13 VH2

-0.93 TEC TEH 23 HOT 600UL 119 37 0.18 161 P 3 TWD 7 DBC

-1.34 TEC TEH 24 HOT 600UL 8

38 0.31 18 P 1 SCI TSH

-0.20 TSH TSH 0.19 19.87 58 HOT 580PP 40 38 0.26 146 P 2 TWD 12 VSM

-0.71 TEC TEH 16 HOT 600UL 0.39 123 P 2 TWO 16 VSM

+0.73 TEC TEH 16 HOT 600UL 56 38 0.42 83 P 2 TWD 17 VH3

-0.87 TEC TEH 16 HOT 600UL 74____38____0.19______133_____P___3___TWO_____12____________+1____68____TEC_______E_____15____HOT______________

74 38 0.19 133 P 3 TWD 12 DBH

+1.68 TEC TEH 15 HOT 600UL 78 38 0.29 137 P 3 TWD 17 DBH

+1.53 TEC TEH 15 HOT 600UL 80 38 0.20 130 P 2 TWD 11 VC3

+0.69 TEC TEH 15 HOT 600UL 0.69 125 P 2 TWD 28 VSM

+0.71 TEC TEH 15 HOT 600UL 0.28 117 P 2 TWD 15 VC3

-0.89 TEC TEH 15 HOT 600UL 0.76 129 P 2 TWD 29 VH3

-0.91 TEC TEH 15 HOT 600UL 0.43 105 P 3 TWD 22 DBH

+1.46 TEC TEH 15 HOT 600UL 84 38 0.29 147 P 2 TWD 12 VH2

+0.69 TEC TEH 24 HOT 600UL 110 38 0.14 123 P 3 TWD 7 DBH

+1.69 TEC TEH 23 HOT 600UL 25 39 0.31 108 P 2 TWD 14 VSM

+1.20 TEC TEH 16 HOT 600UL 31 39 0.19 150 P 2 TWD 11 07H

+0.62 TEC TEH 15 HOT 600UL 81 39 0.30 101 P 2 TWD 15 VC3

+0.87 TEC TEH 27 HOT 600UL

_____39__0.31__69__P_2__TWO__13______-1.01___________TEC_________TE_________23_______HOT_______________________

111 39 0.31 69 P 2 TWD 13 VH2

-1.01 TEC TEH 23 HOT 600UL 113 39 0.41 98 P 2 TWD 16 VH2

-0.98 TEC TEH 24 HOT 600UL 115 39 0.22 92 P 2 TWD 9 VH2

-1.01 TEC TEH 23 HOT 600UL-66 40 0.21 7

P 3 TWD 12 DBC

+1.25 TEC TEH 19 HOT 600UL 76 40 0.35 83 P 2 TWD 15 VH3

+0.69 TEC TEH 20 HOT 600UL 0.20 101 P 3 TWD 9 DBC

+1.95 TEC TEH 20 HOT 600UL 80 40 0.34 94 P 2 TWD 17 VH3

-0.06 TEC TEH 19 HOT 600UL 0.14 139.P 2 TWD 8 VH3

+0.61 TEC TEH 19 HOT 600UL 0.25 88 P 2 TWD 15 VC3

-0.04 TEC TEH 19 HOT 600UL 0.20 118 P 2 TWD 12 VC3

+0.65 TEC TEH 19 HOT 600UL 90 40 0.35 50 P 2 TWD 17 VH2

-0.93 TEC TEH 27 HOT 600UL 94 40 0.64 130 P 2 TWD 25 VSM

+0.75 TEC TEH 27 HOT 600UL 110_____40____0.10______119_____P___3___TWO_________DE________1___59____TEC_____TE______27____HOT______________

110 40 0.10 119 P 3 TWD 5 DBH

+1.59 TEC TEH 27 HOT 600UL 118 40 0.21 117 P 3 TWD 11 DBH

-1.51 TEC TEH 27 HOT 600UL

Framatome ANP Inc.

Customer Name: SONGS Unit 3 10/14/04 11:58:34 Component: S/G 88 Page 5 of 28 MAI, MCI, MMI, MVI, SAI, SCI, SVI, 0-100% TWD QUERY: rpc icodes and 0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 39 41 0.30 145 P 2 TWD 17 VSM

-0.83 TEC TEH 19 HOT 600UL 49 41 0.60 120 P 2 TWD 21 08H

+1.40 TEC TEH LOCOK 20 HOT 600UL 81__41__

0.27 143------P 2

TWO------14-----V--------+0.79--------TEC---------------27 HOT 81 41 0.27 143 P 2 TWD 14 VSM

+0.79 TEC TEH 27 HOT 600UL 0.28 124 P 2 TWD 14 VH3

+0.81 TEC TEH 27 HOT 600UL 0.43 69 P 2 TWD 20 VH3

+0.06 TEC TEH 27 HOT 600UL 0.20 152 P 2 TWD 11 VH3

-0.93 TEC TEH 27 HOT 600UL 113 41 0.18 169 P 3 TWD 10 DBH

+1.81 TEC TEH 27 HOT 600UL 32____42____0.27______127_____P___2___TWO_____12____________+0____74____T_______________20____HOT______________

32 42 0.27 127 P 2 TWD 12 07H

+0.74 TEC TEH 20 HOT 600UL 48 42 0.21 140 P 2 TWD 10 07H

-0.71 TEC TEH 20 HOT 600UL

___________0.25__90__P2_TWO__11______-0.31___________T______________EH______20_______HOT_____________________L_

72 42 0.31 101 P 2 TWD 13 VH3

+0.22 TEC TEH 20 HOT 600UL 0.25 91 P 2 TWD 11 VH3

-0.31 TEC TEH 20 HOT 600UL 0.39 131 P 2 TWD 14 VH3

+0.84 TEC TEH 20 HOT 600UL 110 42 0.35 128 P 2 TWD 17 VH2

-0.75 TEC TEH 27 HOT 600UL 0.11 142 P 2 TWD 6 VH2

+0.84 TEC TEH 27 HOT 600UL 114 42 0.13 135 P 3 TWD 7 DBH

+1.52 TEC TEH 27 HOT 600UL 120 42 0.19 33 P 3 TWD 8 DBC

+1.90 TEC TEH 28 HOT 600UL 124 42 0.26 85 P 2 TWD 11 04C

+0.89 TEC TEH 28 HOT 600UL 33 43 0.15 160 P 2 TWD 7 07H

+0.62 TEC TEH 20 HOT 600UL 37 43 0.47 116 P 2 TWD 18 VSM

+0.66 TEC TEH 20 HOT 600UL 49 43 0.32 - 85 P 2 TWD 11 08H

+1.67 TEC TEH LOCOK 20 HOT 600UL 0.39 81 P 2 TWD 16 08H

-1.43 TEC TEH LOCOK 20 HOT 600UL 97 43 0.33 101 P 2 TWD 14 VH2

+0.85 TEC TEH 28 HOT 600UL 111 43 0.47 99 P 2 TWD 21 VH2

-0.99 TEC TEH 27 HOT 600UL 117 43 0.26 67 P 2 TWD 11 VH2

-1.00 TEC TEH 28 HOT 600UL 123 43 0.22 92 P 2 TWD 12 08C

+0.87 TEC TEH 27 HOT 600UL 56 44 0.41 49 P 2 TWD 16 08H

+0.89 TEC TEH 20 HOT 600UL 58 44 0.32 80 P 2 TWD 16 08H

-0.44 TEC TEH 19 HOT 600UL 72 44 0.23 39 P 3 TWD 10 DBC

+2.11 TEC TEH 20 HOT 60OUL 120 44 0.22 169 P 2 TWD 10 VH1

-1.00 TEC TEH 28 HOT 600UL 67 45 0.17 120 P 2 TWD 10 08H

+0.38 TEC TEH 19 HOT 600UL 73 45 0.40 74 P 2 TWD 16 VC3

+0.13 TEC TEH 20 HOT 600UL 75 45 0.43 122 P 2 TWD 20 VSM

+0.69 TEC TEH 19 HOT 600UL 0.34 150 P 2 TWD 17 VH3

+0.79 TEC TEH 19 HOT 600UL

  • 0.21 85 P 2 TWD 11 VH3

+0.10 TEC TEH 19 HOT 600UL 129 45 0.54 118 P 2 TWD 20 VH1

+0.81 TEC TEH 28 HOT 600UL 36 46 0.29 137 P 2 TWD 13 VSM

+0.78 TEC TEH 20 HOT 600UL 0.37 95 P 2 TWD 15 VSM

-0.76 TEC TEH 20-HOT 600UL 0.22 123 P 2 TWD 7 07H

-0.38 TEC TEH 20 HOT 600UL 56 46 0.61 122 P 2 TWD 21 08H

+0.67 TEC TEH 20 HOT 600UL 128 46 0.25 103 P 2 TWD 11 02C

+0.94 TEC TEH 28 HOT 600UL 17 47 0.34 35 P 2 TWD 15 02H

-1.19 TEH TEC 39 COLD 600UL 27 47 0.33 67 P 2 TWD 15 02H

-1.18 TEH TEC 39 COLD 600UL 35 47 0.34 137 P 2 TWD 15 VSM

+0.69 TEH TEC 39 COLD 600UL 61 47 0.27 139 P 2 TWD 13 08H

+0.65 TEH TEC

-39 COLD 600UL

Framnatome ANP Inc.

l0/14/04 22:58:34 Customer Name: SONGS Unit 3 Component: S/G 88 Page 6 of 28 MAI, MCI, MMI, MVI, SAI, SCI, SVI, 0-100% TWD QUERY: rpc icodes and 0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 75 47 0.27 92 P 2 TWO 13 VH3

+0.08 TEH TEC 37 COLD 600UL 0.32 114 P 3 TWD 13 DBC

+1.75 TEH TEC 37 COLD 600UL 0.21 98 P 2 TWD 11 VC3

+0.28 TEH TEC 37 COLD 600UL 79 47 0.28 84 P 2 TWD 13 VC3

-0.97 TEH TEC 37 COLD 600UL 109 47 0.23 134 P 2 TWD 11 09C

-0.89 TEH TEC 27 COLD 600UL 76 48 0.55 128 P 2 TWD 22 VSM

-0.89 TEH TEC 37 COLD 600UL 0.36 67 P 2 TWD 17 VC3

+0.97 TEH TEC 37 COLD 600UL 0.25 142 P 2 TWD 12 VH3

+0.20 TEH TEC 37 COLD 600UL 0.45 111 P 2 TWD 20 VSM

+0.91 TEH TEC 37 COLD 600UL 0.27 121 P 2 TWD 13 VH3

+0.71 TEH TEC 37 COLD 600UL 0.10 139 P 2 TWD 6 VC3

-0.85 TEH TEC 37 COLD 600UL 86 48 0.26 86 P 2 TWD 12 VH2

-0.80 TEH TEC 27 COLD 600UL 106 48 0.38 119 P 3 TWD 17 DBH

+2.14 TE8 TEC 28 COLD 600UL 118 48 0.42 143 P 2 TWD 18 VH1

-0.73 TEH TEC 27 COLD 600UL 122 48 0.27 89 P 2 TWD 13 VH1

+0.71 TEH TEC 27 COLD 600UL 0.53 89 P 2 TWD 21 VH2

-0.93 TEH TEC 27 COLD 600UL 49 49 0.37 91 P 2 TWD 14 08C

-1.07 TEH TEC 38 COLD 600UL 0.42 114 P 2 TWD 15 08H

+2.15 TEH TEC LOCOK 38 COLD 600UL 0.22 129 P 2 TWD 8 08H

-0.47 TEH TEC 38 COLD 600UL 91__49__

0.27___

114__P2_

TWO___13 ______

0.71___________TE_____

_______EC

_______27_

COLD_________________________L_

91 49 0.27 114 P 2 TWD 13 VH2

-0.71 TEH TEC 27 COLD 600UL 105 49 0.25 42 P 2 TWD 12 VH2

-0.81 TEH TEC 27 COLD 600UL 123 49 0.29 87 P 2 TWD 14 VHl

-0.85 TEH TEC 27 COLD 600UL 125 49 0.31 97 P 2 TWD 13 08C

+0.83 TEH TEC 28 COLD 600UL 36 50 0.32 130 P 2 TWD 13 07H

-0.22 TEH TEC 36 COLD 600UL 0.33 68 P 2 TWD 14 07H

+0.39 TEH TEC 36 COLD 600UL 0.26 148 P 2 TWD 11 07H

+0.89 TEH TEC 36 COLD 600UL 70 50 0.30 87 P 2 TWD 14 08H

-0.99 TEH TEC 37 COLD 600UL 106 50 0.55 87 P 2 TWD 22 VH2

+0.94 TEH TEC 27 COLD 600UL 0.34 130 P 2 TWD 15 VH2

-0.80 TEH TEC 27 COLD 600UL 0.24 115 P 2 TWD 12 VH3

+1.04 TEH TEC 27 COLD 600UL 37 51 0.40 47 P 2 TWD 16 07H

+0.46 TEH TEC 36 COLD 600UL 53 51 0.23 151 P 2 TWD 10 08H

-1.11 TEH TEC 36 COLD 600UL 0.25 142 P 2 TWD 11 07H

-0.30 TEH TEC 36 COLD 600UL 73 51 0.33 87 P 2 TWD 14 VH3

+0.24 TEH TEC 36 COLD 600UL 0.29 138 P 2 TWD 12 VSM

-0.86 TEH TEC 36 COLD 600UL 0.27 140 P 2 TWD 12 VC3

+0.80 TEH TEC 36 COLD 600UL 0.39 121 P 2 TWD 16 VC3

+0.24 TEH TEC 36 COLD 600UL 0.19 25 P 2 TWD 9 VSM

+0.22 TEH TEC 36 COLD 600UL 0.30 141 P 2 TWD 13 VH3

+0.72 TEH TEC 36 COLD 600UL 0.31 84 P 2 TWD 13 VSM

+0.72 TEH TEC 36 COLD 600UL 131 51 0.50 110 P 3 TWD 20 DBC

+1.90 TEC TEH 44 HOT 600UL 0.54 124 P 2 TWD 22 VH2

+0.74 TEC TEH 44 HOT 600UL 133 51 0.21 47 P 2 TWD 9 08C

+0.84 TEC TEH 45 HOT 600UL 36 52 0.34 43 P 2 TWD 14 06H

+0.42 TEH TEC 36 COLD 600UL 106 52 0.15 25 P 3 TWD 7 DBC

-1.71 TEH TEC 29 COLD 600UL 112 52 0.32 11 P 3 TWD 14 DBH

+2.00 TEH TEC 30 COLD 600UL 122_____________________________________________________52_________________________

0.33=---

2 P 2 W 1--+7T-T2CO-122 52 0.33 27 P 2 TWD 14 VH1

+0.73 TEH TEC 29 COLD 600UL 126 52 0.43 128 P 2 TWD 18 VH1

+0.83 TEH TEC 29 COLD 600UL 35 53 0.22 82 P 2 TWD 10 VSM 6TEH TEC 35 COLD 600UL

Framatome ANP Inc.

10/14/04 11:58:34 Customer Name: SONGS Unit 3 Component: S/G 88 Page 7 of 28 MAI, MCI, MMI, MVI, SAI, SCI, SVI, 0-100% TWD

'QUERY:

rpc icodes and 0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE w

43_______________

53__0._8_139_P_2___W__16_______._2__TE__TEC_35__OL-D__-______________________________________

43 53 0.38 139 P 2 TWD 16 VSM

+0.02 TEH TEC 35 COLD 600UL 0.68 140 P 2 TWD 25 VSM

+0.77 TEH TEC 35 COLD 600UL 73 53 0.42 90 P 2 TWD 17 VC3

+0.78 TEH TEC 36 COLD 600UL 0.33 138 P 2 TWD 14 VC3

+0.26 TEH TEC 36 COLD 600UL 0.35 123 P 2 TWD 15 VH3

-0.22 TEH TEC 36 COLD 600UL 28 54 0.29 96 P 2 TWD 13 06H

+0.14 TEH TEC 35 COLD 600UL 64 54 0.32 50 P 2 TWD 14 08H

-0.35 TEH TEC 36 COLD 600UL 116 54 0.33 158 P 3 TWD 13 DBH

+1.94 TEH TEC 30 COLD 600UL 122 54 0.35 114 P 2 TWD 14 VH1

-0.75 TEH TEC 30 COLD 600UL 124 54 0.21 108 P 2 TWD 9 VH1

-0.87 TEH TEC 29 COLD 600UL 0.29 97 P 2 TWD 12 10H

+0.73 TEH TEC 29 COLD 600UL 130 54 0.29 138 P 3 TWD 13 DBH

-1.82 TEH TEC 30 COLD 600UL 132 54 0.19 118 P 3 TWD 9 DBH

-1.70 TEC TEH 44 HOT 600UL 79 55 0.19 167 P 3 TWD 7 DBH

+1.82 TEH TEC 35 COLD 600UL 131 55 0.23 19 P 3 TWD 11 DBH

+1.86 TEC TEH 44 HOT 600UL 10 56 0.58 21 P 1 SCI TSH

-0.05 TSH TSH 0.16 18.11 55 HOT 580PP 48 56 0.39 40 P 2 TWD 16 02H

-1.07 TEH TEC 36 COLD 600UL 76____56____0___22____113_____P___2____W_____10______________0___91______E____TEC_____36____COLD______________L 76 56 0.22 113 P 2 TWD 10 05C

+0.91 TEH TEC 36 COLD 600UL 0.29 112 P 2 TWD 12 04C

+0.90 TEH TEC 36 COLD 600UL 1

0.21 126 P 2 TWD 9 03C

+0.96 TEH TEC 36 COLD 600UL 120 56 0.56 95 P 2 TWD 21 10H

+1.59 TEH TEC LOCOK 29 COLD 600UL 124 56 0.21 158 P 3 TWD 9 DBH

+2.08 TEH TEC 29 COLD 600UL 126 56 0.12 31 P 2 TWD 7 VH1

-0.79 TEH TEC 29 COLD 600UL 130 56 0.17 133 P 3 TWD 7 DBH

-1.53 TEH TEC 29 COLD 600UL 132 56 0.12 110 P 3 TWD 5 DBH

-2.05 TEC TEH 44 HOT 600UL 75 57 0.27 119 P 2 TWD 12 VH3

+0.79 TEH TEC 36 COLD 600DUL 0.65 134 P 2 TWD 23 VSM

+0.81 TEH TEC 36 COLD 600UL 0.25 113 P 2 TWD 11 VC3

-0.79 TEH TEC 36 COLD 600UL 0.12 151 P 2 TWD 6 VH3

+0.20 TEH TEC 36 COLD 600UL 77 57 0.38 112 P 2 TWD 16 VC3

+0.18 TEH TEC 35 COLD 600UL 0.55 61 P 2 TWD 22 VC3

+0.86 TEH TEC 35 COLD 600UL 81 57 0.44 105 P 2 TWD 17 07H

+0.88 TEH TEC 30 COLD 600UL 85 57 0.85 5l9 P 2 TWD 28 08H

-0.76 TEH TEC 30 COLD 600UL 89 57 0.50 122 P 2 TWD 19 09H

+0.53 TEH TEC 30 COLD 600UL 123 57 0.31 153 P 3 TWD 14 DBH

+2.24 TEH TEC 30 COLD 600UL 131 57 0.18 106 P 3 TWD 8 DBH

+1.76 TEC TEH 44 HOT 600UL 135 57 0.31 10 P 3 TWD 12 DBH

+1.33 TEC TEH 45 HOT 600UL 128_____58____0__48____1___7___P__2___TWO_____19_____________0__81____T_________TEC____30____COLD______________

72 58 0.40 108 P 2 TWD 16 08H

+0.71 TEH TEC 36 COLD 600UL 76 58 0.21 58 P 3 TWD 10 DBC

-2.02 TEH TEC 36 COLD 600UL 84 58 0.50 148 P 2 TWD 19 VH2

-0.95 TEH TEC 29 COLD 600VL 0.46 98 P 2 TWD 19 09H

-1.24 TEH TEC 29 COLD 600UL 0.74 82 P 2 TWD 26 09H

+1.65 TEH TEC LOCOK 29 COLD 600UL 118 58 0.33 13 P 3 TWD 15 DBH

+2.16 TEH TEC 30 COLD 600UL 128 58 0.48 107 P 2 TWD 19 VH3

+0.81 TEH TEC 30 COLD 600UL

Framatome ANP Inc.

Customer Name: SONGS Unit 3 MAI, MCI, MMI, NVI, SAI, SCI, SVI, 0-100% TWD QUERY: rpc icodes and 0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION 0.23 21 P 2 TWD*9 VH3

+0.26 134 58 0.33 65 P 2 TWD 13 VC1

-0.96 0.27 129 P 2 TWD 11 VC2

-0.77 10/14/04 11:58:34 Component: S/G 88 Page 8 of 28 EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 1_,______

-=

TEH TEC 30 COLD 600UL

,_______________________TEC________E_____45____HOT________________

TEC TEH 45 HOT 600UL

  • TEC TEH 45 HOT 600UL 69 59 0.18 57 P 3 TWD 9 DBC

+1.75 TEH TEC 36 COLD 600UL 79 59 0.35 143 P 3 TWD 13 DBH

+2.16 TEH TEC 35 COLD 600UL 81 59 0.26 167 P 3 TWD 11 DBH

+1.66 TEH TEC 29 COLD 600UL 0.68 125 P 2 TWD 25 VC3

-0.77 TEH TEC

  • 29 COLD 600UL 0.64 56 P 2 TWD 23 VC3

-0.06 TEH TEC 29 COLD 600UL 89 59 0.30 35 P 2 TWD 13 01H

+0.77 TEH TEC 29 COLD 600UL 0.48 114 P 2 TWD 19 09H

+0.87 TEH TEC 29 COLD 600UL 121 59 0.12 11 P 3 TWD 5 DBC

-1.54 TEH TEC 29 COLD 600UL 123 59 0.26 59 P 2 TWD 10 VH1

+0.73 TEH TEC 30 COLD 600UL 137 59 0.45 37 P 3 TWD 17 DEC

+1.63 TEC TEH 45 HOT 600UL 8

60 0.26 135 P 3 TWD 10 DBH

-0.69 TEC TEH 38 HOT 600UL 84 60 0.40 116 P 2 TWO 16 09H

-1.08 TEH TEC 29 COLD 600UL 86_60_0.27_153_P_2_T____1____

0.80-----------TEH--------TEC--------30------COLD------------------------

86 60 0.27 153 P 2 TWD 11 08H

-0.80 TEH TEC 30 COLD 600UL 0.25 704 P 2 TWD 10 09H

-0.89 TEH TEC 30 COLD 600UL 96 60 0.34 77 P 2 TWD 15 09H

-0.28 TEH TEC 30 COLD 600UL 100 60 0.74 75 P 2 TWD 26 VH2

-0.73 TEH TEC 30 COLD 600UL 126 60 0.59 122 P 2 TWD 22 VH1

-0.97 TEH TEC 32 COLD 600UL 134 60 0.44 71 P 3 TWD 17 D8H

+1.66 TEC TEH 45 HOT 600UL 136 60 0.53 97 P 3 TWD 21 DBH

+1.45 TEC TEH 44 HOT 600UL 0.40 143 P 2 TWD 18 VC3

-0.80 TEC TEH 44 HOT 600UL 0.17 172 P 3 TWD 8 DBC

+2.11 TEC TEH 44 HOT 600UL 73 61 0.44 103 P 2 TWD 18 VSM

+0.83 TEH TEC 36 COLD 600UL 85 61 0.52 78 P 2 TWD 20 08H

+0.55 TEH TEC 31 COLD 600UL 87_____61____0.53______34____P2____TWO_____20____________+0____75____TEE_____TEC_____32____COLD________________

87 61 0.53 34 P 2 TWO 20 08H

+0.75 TEH TEC 32 COLD 600UL 89 61 0.51 132 P 2 TWD 20 09H

+0.85 TEH TEC 31 COLD 600UL 93 61 0.71 84 P 2 TWO 25 09H

+0.75 TEH TEC 31 COLD 600UL 97 61 0.21 142 P 2 TWD 9 04C

-0.97 TEH TEC 32 COLD 600UL 133 61 0.10 95 P 3 TWD 6 DBC

-1.75 TEC TEH 44 HOT 600UL 40 62 0.43 77 P 2 TWD 17 VSM

+0.85 TEH TEC 34 COLD 600UL 46 62 0.35 87 P 3 TWD 14 DBH

+2.24 TEH TEC 33 COLD 600UL 74 62 0.16 14 P 3 TWD 7 DBH

+1.93 TEH TEC 33 COLD 600UL 76 62 0.29 105 P 2 TWD 12 04C

+0.93 TEH TEC 34 COLD 600UL 82 62 0.39 62 P 2 TWD 16 VH3

+0.85 TEH TEC 32 COLD 600UL 86 62 0.45 146 P 2 TWD 18 VH2

-0.75 TEH TEC 32 COLD 600UL 90 62 0.51 76 P 2 TWD 20 VH2

-0.77 TEH TEC 31 COLD 600UL 94 62 0.33 80 P 2 TWD 14 09H

+0.00 TEH TEC 32 COLD 600UL 110 62 0.33 67 P 2 TWD 14 VH2

-0.91 TEH TEC 32 COLD 600UL 126 62 0.33 123 P 2 TWD 14 VH1

-1.19 TEH TEC 32 COLD 600UL 0.20 104 P 2 TWO 9 VH1

+0.04 TEH TEC 32 COLD 600UL

Framatome ANP Inc.

10/14/04 11:58:34 Customer Name: SONGS Unit 3 Component: S/G 88 Page 9 of 28 MAI, MCI, MMI, MVI, SAI, SCI, SVI, 0-100% TWD QUERY: rpc icodes and_0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 37 63 0.37 93 P 2 TWD 15 VSM

+0.75 TEH TEC 34 COLD 60OUL 61 63 0.49 126 P 2 TWD 19 08H

-0.99 TEH TEC 34 COLD 600UL 81 63 0.38 133 P 2 TWD 16 VSM

-0.83 TEH TEC 32 COLD 600UL 93 63 0.35 59 P 2 TWD 15 09H

+1.00 TEH TEC 32 COLD 600UL

.95 63 0.53 104 P 2 TWD 21 09H

+0.28 TEH TEC 31 COLD 600UL 141 63 0.21 145 P 2 TWD 9 08H

+0.70 TEC TEH 45 HOT 600VL 0.39 64 P 3 TWD 15 DBH

-1.12 TEC TEH 45 HOT 600UL 90 64 0.43 86 P 2 TWD 17 VH2

-0.79 TEH TEC 32 COLD 600UL 94 64 0.30 128 P 2 TWD 13 08H

-0.45 TEH TEC 32 COLD 600UL 0.30 129 P 2 TWD 13 09H

+0.26 TEH TEC 32 COLD 600UL 106 64 0.34 136 P 2 TWD 14 VC2

-0.83 TEH TEC 32 COLD 600UL 108 64 0.25 33 P 3 TWD 10 DBH

+1.88 TEH TEC 31 COLD 600UL 116 64 0.22 151 P 3 TWD 8 DBH

+1.80 TEH TEC 31 COLD 600UL 134__64__0.44__148__P_2_TWO__19______-0.96__________T_____________T_________40______COLD_____________________L_

134 64 0.44 148 P 2 TWD 19 VH2

-0.96 TEH TEC 40 COLD 600UL 138 64 0.32 125 P 2 TWD 15 VH2

-0.88 TEH TEC 40 COLD 600UL 140 64 0.33 132 P 2 TWD 15 VH2

-0.84 TEH TEC 40 COLD 600UL 9

65 0.18 129 P 3 TWD 8 DBH

+0.65 TEC TEH 38 HOT 600UL 39 65 0.47 115 P 2 TWD 19 VSM

+0.79 TEH TEC 33 COLD 600UL 45 65 0.32 145 P 2 TWD 13 02H

-1.19 TEH TEC 34 COLD 600UL 73 65 0.27 126 P 2 TWD 11 VH3

+0.91 TEH TEC 34 COLD 600UL 0.41 104 P 2 TWD 16 VH3

-0.81 TEH TEC 34 COLD 600UL 81 65 0.70 135 P 2 TWD 25 VSM

+0.98 TEH TEC 31 COLD 600UL 95 65 0.79 84 P 2 TWD 26 09H

-0.16 TEH TEC 32 COLD 600UL 9

0.36 80 P 2 TWD 15 08H

+0.32 TEH TEC 32 COLD 600UL 0.20 145 P 2 TWD 9 09H

+0.89 TEH TEC 32 COLD 600UL 97 65 0.27 118 P 2 TWD 12 09H

-0.71 TEH TEC 31 COLD 600UL 99 65 0.42 122 P 2 TWD 17 08H

+0.68 TEH TEC 32 COLD 600UL 121 65 0.37 59 P 2 TWD 15 VH1

+0.79 TEH TEC 31 COLD 600UL 50 66 0.33 27 P 2 TWD 14 08V

-1.16 TEH TEC LOCOd 34 COLD 600UL

_________________0.25_____39____P___2__TWO_____10___V_________+0___92____TEH____TEC____31____COLD_____________L 92 66 0.35 144 P 2 TWD 15 09H

-0.08 TEH TEC 32 COLD 600UL 0.28 25 P 2 TWD 12 09H

+1.01 TEH TEC 32 COLD 600UL 94 66 0.22 126 P 2 TWD 10 09H

+0.61 TEH TEC 31 COLD 600UL 27____67____0.44______124_____P___2__TWO_____17____V_______+1.19_______TE_____T___d___34____COLD______________L 96 66 0.31 42 P 2 TWD 13 OSH

-0.10 TEH TEC 32 COLD 600UL 98 66 0.33 35 P 2 TWD 14 09H

+0.81 TEH TEC 31 COLD 600UL 102 66 0.27 107 P 2 TWD 12 09H

+0.87 TEH TEC 31 COLD 600UL 110 66 0.25 49 P 2 TWD 11 VH2

-0.97 TEH TEC 31 COLD 600UL 126 66 0.50 108 P 2 TWD 19 VH1

-0.70 TEH TEC 31 COLD 600UL 0.25 39 P 2 TWD 10 VH1

+0.92 TEH TEC 31 COLD 600UL 134 66 0.32 138 P 2 TWD 15 VH1

-0.88 TEH TEC 40 COLD 600UL 0.42 140 P 2 TWD 18 VH2

-0.94-TEH TEC 40

.COLD 600UL 17 67 0.26 61 P 3 TWD 11 DBH

+1.89 TEH TEC 34 COLD 600UL 27 67 0.44 124 P 2 TWD 17 VSM

+1.19 TEH TEC 34 COLD 600UL

Framatome ANP Inc.

10/14/04 11:58:34 Customer Name: SONGS Unit 3 Component: S/G 88 Page 10 of 28

MAI, MCI,
MMI, MVI,
SAI, SCI,
SVI, 0-100% TWD QUERY: rpcicodes and_0-100%twd.qry

.I ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 39 67 0.49 10 P 2 T-20

-0.75-_--T_

33_COLD ---

39 67 0.49 106 P 2 TWD 20 VSM

-0.75 TEH TEC 33 COLD 600UL 0.40 140 P 2 TWD 17 VSM

-+0.63 TEH TEC 33 COLD 600UL 53 67 0.58 114 P 2 TWD 22 08H

-0.98 TEH TEC 34 COLD 600UL 57 67 0.30 17 P 1 SCI TSH

-10.41 TSH TSH 0.15 18.31 140 HOT 580PP 95___67 __0.44 ___106

__P __2 T

18--------------+0.61 TEH-----T 31_____ COLD_____

95 67 0.44 106 P 2 TWD 18 09H

+0.61 TEH TEC 31 COLD 600UL 101 67 0.58 61 P 2 TWD 22 09H

+0.83 TEH TEC 32 COLD 600UL 125 67 0.34 37 P 2 TWD 14 VH1

+0.89 TEH TEC 31 COLD 600UL 141 67 0.28 55 P 3 TWD 14 DBH

+1.54 TEC TEH 47 HOT 600UL 40 68 0.35 92 P 2 TWD 16 VSM

-1.00 TEH TEC 33 COLD 600UL 0.96 116 P 2 TWD 30 VSM

+0.81 TEH TEC 33 COLD 600UL 48 68 0.44 104 P 2 TWD 18 VSM

+0.95 TEH TEC 33 COLD 600UL 76 68 0.48 67 P 2 TWD 20 07H

+0.99 TEH TEC 33 COLD 600UL 82 68 0.30 149 P 2 TWD 13 VH3

-0.79 TEH TEC 32 COLD 600UL 0.35 128 P 2 TWD 15 VSM

-0.28 TEH TEC 32 COLD 600UL 88 68 0.35 71 P 2 TWD 15 08H

-1.02 TEH TEC 31 COLD 600UL 92 68 0.79 130 P 2 TWD 26 09H

-0.14 1

TEH TEC 31 COLD 600UL 94 68 0.39 138 P 2 TWD 16 VH2

+0.77 TEH TEC 32 COLD 600UL 96 68 0.30 63 P 2 TWD 13 09H

+0.77 TEH TEC 31 COLD 600UL 98 68 0.34 26 P 3 TWD 15 DBH

+2.24 TEH TEC 32 COLD 600UL 112 68 0.32 91 P 2 TWD 13 VH2

-0.93 TEH TEC 31 COLD 600UL 132 68 0.29 95 P 2 TWD 15 VH2

-0.84 TEC TEH 47 HOT 600UL 138 68 0.19 60 P 3 TWD 10 DBH

+1.98 TEC TEH 47 HOT 600UL 31 69 0.64 104 P 2 TWD 23 07H

-1.04 TEH TEC 34 COLD 600UL 37 69 0.38 154 P 2 TWD 17 VSM

+0.97 TEH TEC 33 COLD 600UL 81 69 0.27 63 P 2 TWD 12 VSM

-0.61 TEH TEC 31 COLD 600UL 0.53 62 P 2 TWD 20 VC3

+0.85 TEH TEC 31 COLD 600UL 0.26 122 P 2 TWD 12 VC3

-0.99 TEH TEC 31 COLD 600UL 0.13 114 P 3 TWD 6 DBH

+0.95 TEH TEC 31 COLD 600UL 0.17 89 P 3 TWD 7 DBH

+1.20 TEH TEC 31 COLD 600UL 0.33 23 P 2 TWD 14 VH3

-0.02 TEH TEC 31 COLD 600UL 91____69

____0.47

______114

_____P___2__TWD_____18____________+0.77_______TEH____TEC_____32

____COLD _______________

91 69 0.47 114 P 2 TWD 18 08H

+0.77 TEH TEC 32 COLD 600UL 0.41 107 P 2 TWD 17 09H

-0.20 TEH TEC 32 COLD 600UL 95 69 0.29 136 P--2--T-----12--------+0.26----TEH

-TEC -

32---------COLD---------------------------L--

93 69 0.32 126 P 2 TWD 14 09H

+0.73 TEH TEC 31 COLD 600UL 95 69 0.29 136 P 2 TWD 12 08H

+0.26 TEH TEC 32 COLD 600UL 97 69 0.25 43 P 2 TWD 11 07H

+0.88 TEH TEC 31 COLD 600UL 125 69 0.26 40 P 2 TWD 11 10H

+0.04 TEH TEC 31 COLD 600UL 137 69 0.29 99 P 2 TWD 13 VH1

-1.01 TEC TEH 49 HOT 600UL 0.21 137 P 2 TWD 10 VH1

+0.88 TEC TEH 49 HOT 600UL 139 69 0.28 140 P 2 TWD 15 VH1

+0.75 TEC TEH 47 HOT 600UL 1.00 106 P 2 TWD 33 VC1

-0.88 TEC TEH 47 HOT 600UL 141 69 0.20 37 P 3 TWD 9 DBC

+2.03 TEC TEH 49 HOT 600UL 0.21 62 P 3 TWD 9 DBH

+1.69 TEC TEH 49 HOT 600UL 88 70 0.58 101 P 2 TWD 22 VH2

-0.79 TEH TEC 31 COLD 600UL 96 70 0.81 123 P 2 TWD 27 07H

+0.79 TEH TEC 31 COLD 600UL 0.17 148 P 2 TWD 8 09H

-0.10 TEH TEC 31 COLD 600UL

Framatome ANP Inc.

Customer Name: SONGS Unit 3 MAI, MCI, MMI, MVI, SAI, SCI, SVI, 0-100% TWD QUERY: rpc icodes and 0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION 10/14/04 11:58:34 Component: S/G 88 Page 11 of 28 EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 132 70 0.63 108 P 2 TWD 26 VH1

+0.63 TEC TEH 47 HOT 600UL 0.20 75 P 2 TWD 11 VH1

+0.12 TEC TEH 47 HOT 600UL 136 70 0.54 36 P 2 TWD 23 VH1

+0.85 TEC TEH 47 HOT 600UL 138 70 0.19 105 P 3 TWD 10 DBH

+1.59 TEC TEH 49 HOT 600UL 95__71__0.26__132__p_2__TWD__12______-0.87___________T__________TEC________31______COLD________________________

95 71 0.26 132 P 2 TWD 12 07H

-0.87 TEH TEC 31 COLD 600UL 101 71 0.30 154 P 2 TWD 13 09H

+0.75 TEH TEC 32 COLD 600UL 0.24 107 P 3 TWD 11 DBH

-1.75 TEH TEC 32 COLD 600UL 103 71 0.35 30 P 2 TWD 15 09H

+0.87 TEH TEC 31 COLD 600UL 141_____71____0.20______56____P_______TWD_______________H___+1____61____TEC_____________47____HOT______________

141 71 0.20 56 P 3 TWD 11 DBH

+1.61 TEC TEH.47 NOT 600UL 143 71 0.52 136 P 3 TWD 20 DBH

+1.86 TEC TEH 49 HOT 600UL 0.41 40 P 3 TWD 17 DBH

-1.64 TEC TEH 49 HOT 600UL 76 72 0.27 88 P 2 TWD 12 VH3

-0.61 TEH TEC 33 COLD 600UL 92 72 0.42 84 P 2 TWD 17 05H

+0.85 TEH TEC 31 COLD 600UL 0.47 128 P 2 TWD 19 09H

-0.04 TEH TEC 31 COLD 600UL 94____72

____0.28 _______48___P___2___T______12___________+0.3____

___TE______TEC____32

_ ___COLD ______________

94 72 0.28 148 P 2 TWD 12 07H

+0.31 TEH TEC 32 COLD 600UL

___________0.15__73__p_2__TWO_6______-0.97_____________E___________EC______31______COLD______________________L_

96 72 0.29 42 P 2 TWD 13 09H

+0.28 TEH TEC 31 COLD 600UL 0.15 73 P 2 TWD 6 09H

-0.97 TEH TEC 31 COLD 600UL 98 72 0.66 72 P 2 TWD 23 07H

+0.79 TEH TEC 32 COLD 600UL 112__72__0.49__104__p_2_T__D_19______-0.86___________TE____________E_______31______COLD______________________L_

106 72 0.38 146 P 2 TWD 16 VC2

-0.85 TEH TEC 32 COLD 600UL 110 72 0.46 100 P 2 TWD 18 VH2

-0.99 TEH TEC 32 COLD 600UL 112 72 0.49 104 P 2 TWD 19 VH2

-0.86 TEH TEC 31 COLD 600UL 130 72 0.26 106 P 2 TWD 11 VH1

-0.87 TEH TEC 31 COLD 600UL 140 72 0.36 19 P 3 TWD 17 D3H

+1.98 TEC TEH 47 HOT 600UL 142 72 0.36 107 P 3 TWD 15 DBH

+1.49 TEC TEH 49 HOT 600UL 0.41 133 P 2 TWD 17 VH1

+0.90 TEC TEH 49 HOT 600UL 41 73 0.29 123 P 3 TWD 13 D8H

-1.54 TEH TEC 34 COLD 600UL

__________________0.28_____68______2___TW_____12____________+0.85______TEH_____TEC_____32

___COLD _______________

43 73 0.39 89 P 2 TWD 17 VSM

-0.85 TEH TEC 33 COLD 600UL 47 73 0.57 87 P 3 TWD 20 DBC

-1.86 TEH TEC 33 COLD 600UL 77 73 0.34 83 P 2 TWD 14 VH3

+0.91 TEH TEC 34 COLD 600UL 91 73 0.38 141 P 2 TWD 16 08H

+0.83 TEH TEC 32 COLD 600UL 0.79 144 P 2 TWD 26 09H

-0.30 TEH TEC 32 COLD 600UL 93 73 0.40 149 P 2 TWD 17 09H

+0.85 TEH TEC 31 COLD 600UL 95 73 0.61 73 P 2 TWD 22 09H

+0.55 TEH TEC 32 COLD 600UL 0.28 68 P 2 TWD 12 VH3

+0.85 TEH TEC 32 COLD 600UL 0.39 148 P 2 TWD 16 VSM

+0.75 TEH TEC 32 COLD 600UL 0.34 137 P 2 TWD 14 VH3

+0.04 TEH TEC 32 COLD 600UL 0.46 33 P 2 TWD 18 VC2

+0.06 TEH TEC 32 COLD 600UL 0.15 130 P 2 TWD 7 07H

-0.94 TEH TEC 32 COLD 600UL 97 73 0.29 118 P 2-TWD 13 08H

-0.61 TEH TEC 31 COLD 600UL 0.38 114 P 2 TWD 16 08H

+0.73 TEH TEC 31 COLD 600UL 0.58 112 P 2 TWD 22 09H

+0.65 TEH TEC 31 COLD 600UL 42 74,0.57 96 P 3 TWD 22 DBH

-1.76 TEH TEC 34 COLD 600UL 44 74 0.34 96' P 3 TWD 13 DBH

-1.95 TEH TEC 33 COLD 600UL 0.41 145 P 3 TWD 16 DBC

'+1.92 TEH TEC 33 COLD 600UL 66 74 0.42 144 P 3 TWD 18 DBH

+1.71 TEH TEC 34 COLD 600UL

Framatome ANP Inc.

10/14/04 11:58:35 Customer Name: SONGS Unit 3 Component: S/G 88 Page 12 of 28 MAI, MCI, MMI, MVI, SAI, SCI, SVI, 0-100% TWD QUERY: rpc icodes and 0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL Y LEG PROBE 82 74 0.56 23 P 3 TWD 22 DBH

+1.92 TER TEC 32 COLD 600UL 92 74 0.56 105 P 2 TWD 21 07H

+0.82 TEA TEC 31 COLD 600UL 0.26 19 P 2 TWD 12 09H

+0.87 TER TEC 31 COLD 600UL 94__74__ 0.28__

61_P__ 2_TD__

12_ 09____

0.40_

TE___________

T____________31_______COLD________________________L__

94 74 0.28 61 P 2 TWD 12 09H

-0.40 TER TEC 31 COLD 600UL 100 74 0.34 152 P 2 TWD 14 09H

+0.95 TEH TEC 31 COLD 600UL 0.30 54 P 2 TWD 13 09H

-0.06 TEH TEC 31 COLD 600UL 102 74 0.20 156 P 2 TWD 9 09H

+0.71 TER TEC 32 COLD 600UL 130 74 0.53 119 P 2 TWD 20 VH1

-0.93 TER TEC 31 COLD 600UL 134 74 0.36 94 P 2 TWD 18 VH1

-0.89 TEC TER 47 HOT 600UL 138 74 0.73 112 P 2 TWD 28 VH1

-0.95 TEC TER 47 HOT 600UL 0.37 114 P 2 TWD 18 VH2

-1.01 TEC TER 47 HOT 600UL 142 74 0.22 44 P 3 TWD 12 DBH

+1.85 TEC TER 47 HOT 600UL 4

75__0.33___130__P___TD__14______-1.79__TEATC_34_COLD__

45 75 0.33 130 P 3 TWD 14 DBC

-1.79 TEH TEC 34 COLD 600UL 47 75 0.36 91 P 3 TWD 14 DBC

-1.75 TER TEC 33 COLD 600UL 75 75 0.52 125 P 2 TWO 21 VSM

-0.87 TER TEC 33 COLD 600UL 0.36 123 P 2 TWD 16 VSM

+1.05 TEH TEC 33 COLD 600UL 93 75 0.71 77 P 2 TWD 25 09H

-0.26 TEA TEC 31 COLD 600UL 103 75 0.37 48 P 2 TWD 15 VH2

+0.80 TEA TEC 32 COLD 600UL 0.22 113 P 2 TWD 10 09H

+0.46 TER TEC 32 COLD 600UL 0.35 82 P 2 TWD 15 09H

+1.01 TER TEC 32 COLD 600UL 0.51 122 P 2 TWD 20 09H

-0.85 TEA TEC 32 COLD 600UL 0.29 116 P 2 TWD 13 09H

+0.72 TEH TEC 32 COLD 600UL 129 75 0.33 71 P 2 TWD 14 VH1

+0.84 TEA TEC 31 COLD 600UL 133 75 0.39 46 P 2 TWD 18 10H

+0.81 TEC TEA 47 HOT 600UL 143 75 0.33 64 P 3 TWD 14 DBH

+1.67 TEC TEA 49 HOT 600UL 46 76 0.23 102 P 3 TWD 15 DBH

-2.03 TEC TEA 6

HOT 600UL 92 76 0.32 46 P 2 TWD 13 09H

-0.25 TEA TEC 23 COLD 600UL 112 76 0.41 142 P 2 TWD 16 VH2

-1.00 TEA TEC 24 COLD 600UL 120 76 0.39 144 P 2 TWD 15 VH1

-0.86 TEA TEC 24 COLD 600UL 0.35 154 P 2 TWD 13 VH2

-0.96 TEA TEC 24 COLD 600UL 0.32 66 P 2 TWD 12 VH2

+0.86 TEA TEC 24 COLD 600UL 124 76 0.25 114 P 3 TWD 10 DBH

+1.87 TEA TEC 24 COLD 600UL 0.48 121 P 2 TWD 18 VH2

-0.85 TER TEC 24 COLD 600UL 130 76 0.70 90 P 2 TWD 24 VH1

+0.76 TEA TEC 23 COLD 600UL 136 76 0.39 140 P 2 TWD 19 VH1

+0.61 TEC TEA 47 HOT 600UL 138 76 0.46 125 P 2 TWD 18 VH2

-0.94 TEC TEA 49 HOT 600UL 0.37 106 P 2 TWD 16 VH1

-0.26 TEC TEA 49 HOT 600UL 140 76 0.52 125 P 2 TWD 20 VH1

-0.93 TEC TEA 49 HOT 600UL 47 77 0.37 120 P 3 TWD 17 DBC

-1.93 TEC TEA 5

HOT 60OUL 49 77 0.26 65 P 2 TWD 14 06H

-0.91 TEC TEA 6

HOT 600UL 93 77 0.46 68 P 2 TWD 18 09H

-0.22 TEA TEC 23 COLD 600UL 95 77 0.30 101 P 2 TWD 13 08H

+0.48 TEA TEC 45 COLD 600UL 101 77 0.27 136 P 2 TWD 11 09H

-0.69 TEA TEC 23 COLD 600UL 0.78 102 P 2 TWD 26 09H

+0.65 TEA TEC 23 COLD 600UL 121__77__0.12__130__P__3_TWO__4__DEC_-0.82__________TEA________TEC__________3_____COLD_________________________

121 77 0.12 130 P 3 TWD 4 DBC

-0.82 TER TEC 23 COLD

.600UL

Framatome ANP Inc.

10/14/04 11:58:35 Customer Name: SONGS Unit 3 Component: S/G 88 Page 13 of 28 MAI, MCI, MMI, MVI, SAI, SCI, SVI, 0-100% TWD QUERY:.rpcicodes and_0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 46 78 0.93 14 P 3 TWD 35 DEH

+1.58 TEC TEH 6

HOT 600UL 0.23 136 P 3 TWD 14 DEH

-1.62 TEC TEH 6

HOT 600UL 66 78 0.27 110 P 2 TWD 15 02H

-0.28 TEC TEH 5

HOT 60OUL 90 78 0.37 93 P 2 TWD 16 09H

-0.06 TEH TEC 45 COLD 600UL 0.26 146 P 2 TWD 12 09H

+0.69 TEH TEC 45 COLD 600UL 94__78__0.41__116__P_2____D__16______-0.12___________TEH_____________C_____24______COLD______________________L_

94 78 0.41 116 P 2 TWD 16 09H

-0.12 TEH TEC 24 COLD 600UL 0.41 145 P 2 TWD 15 09H

+0.38 TEH TEC 24 COLD 600UL 102 78 0.57 118 P 2 TWD 20 09H

+0.95 TEH TEC 24 COLD 600UL 104 78 0.18 152 P 2 TWD 7 09H

+0.39 TEH TEC 23 COLD 600UL 128__78__0.50__130__P_2_T____19______-0.94___________TEH________TEC________23______COLD______________________L_

118 78 0.34 148 P 2 TWD 13 VH1

-0.77 TEH TEC 24 COLD 600UL 128 78 0.50 130 P 2 TWD 19 VH1

-0.94 TEH TEC 23 COLD 600UL 130 78 0.36 111 P 2 TWD 15 VH1

-0.90 TEH TEC 23 COLD 600UL 142_____78____0.38______19____P___3___________16____________+1.50_______TEC_____TEH_____49____HOT______________

136 78 0.42 121 P 2 TWD 20 VH1

-0.91 TEC TEH 47 HOT 600UL 140 78 0.20 i48 P 2 TWD 11 VH1

-0.97 TEC TEH 47 HOT 600UL 142 78 0.38 19 P 3 TWD 16 DBH

+0.50 TEC TEH 49 HOT 600UL 0.79 124 P 2 TWD 26 VH1

-0.90 TEC TEH 49 HOT 600UL 57 79 0.27 119 P 3 TWD 17 DBC

-1.82 TEC TEH 6

HOT 600UL 61 79 0.53 79 P 2 TWD 24 VSM

+0.85 TEC TEH 6

HOT 600UL 91 79 0.23 79 P 2 TWD 10 07H

+0.33 TEH TEC 46 COLD 600UL 0.37 125 P 2 TWD 15 09H

+0.43 TEH TEC 46 COLD 600UL 93 79 0.27 112 P 2 TWD 12 09H

-0.26 TEH TEC 45 COLD 600UL 99 79 0.39 103 P 2 TWO 16 07H

+0.78 TEH TEC 46 COLD 600UL 101 79 0.63 75 P 2 TWD 24 09H

+0.91 TEH TEC 45 COLD 600UL 103 79 0.31 133 P 2 TWO 13 09H

-0.91 TEH TEC 46 COLD 600UL 0.33 105 P 2 TWD 14 09H

+0.18 TEH TEC 46 COLD 600UL 0.36 122 P 2 TWD 15 09H

+0.67 TEH TEC 46 COLD 600UL 119 79 0.20 148 P 3 TWD 8 DBH

+0.16 TEH TEC 24 COLD 600UL 143 79 0.56 96 P 3 TWD 21 DBH

+1.83 TEC TEH 49 HOT 600UL 48 80 0.84 94 P 3 TWD 29 DBH

-1.30 TEC TEH 5

HOT 600UL 0.16 144 P 3 TWD 8 DBC

-1.47 TEC TEH 5

HOT 600UL 80 80 0.47 80 P 2 TWD 23 VSM

+0.88 TEC TEH 5

HOT 600UL 126 80 0.39 130 P 2 TWD 16 VH1

-0.75 TEH TEC 46 COLD 600UL 140 80 0.35 37 P 3 TWD 15 DBH

-1.88 TEC TEH 49 HOT 600UL 0.72 103 P 2 TWD 25 VH1

-0.80 TEC TEH 495 HOT 600UL 144 80 0.41 155 P 3 TWD 17 DBC

+2.07 TEC TEH 49 HOT 600UL 0.18 12 P 3 TWD 9 DBH

+1.91 TEC TEH 49 HOT 600UL 61 81 0.22 10 P 3 TWO 11 DBH

+1.54 TEC TEH 5

HOT 600UL 81 81 0.34 142 P 2 TWD 15 VH3

-0.83 TEH TEC 45 COLD 600UL 0.29 81 P 2 TWD 13 VC3 0.04 TEH TEC 45 COLD 600UL 0.38 148 P 2 TWO 16 VH3

+0.83 TEH TEC 45 COLD 600UL 0.32 130 P 2 TWO 14 VSM

+0.91 TEH TEC 45 COLD 600UL 0.62 132 P 2 TWD 24 VC3

-0.97 TEH TEC 45 COLD 600UL 0.52 76 P 2 TWD 21 VC3

+0.93 TEH TEC 45 COLD 600UL 99 81 0.51 138 P 2 TWD 19 09H

+0.71 TEH SEC 46 COLD 600UL 101 81 0.64 147 P 2 TWD 24 09H

-1.01 TEH SEC 45 COLD 600UL

Framatome ANP Inc.

10/14/04 11.58:35 Customer Name: SONGS Unit 3 Component: S/G 88 Page 14 of 28 MAI, MCI, MMI, MVI, SAI, SCI, SVI, 0-100% TWD QUERY: rpc icodes and 0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL Y LEG PROBE 103 81 0.62 91 P 2 TWD 22 09H

+0.93 TEH TEC 46 COLD 600UL 113 81 0.28 87 P 3 TWD 11 DBH

+1.93 TEH TEC 45 COLD 600UL 121 81 0.38 79 P 2 TWD 17 VH1

+0.55 TEH TEC 45 COLD 600UL 52__82__0.57__73__P_3__TW___23_D_____-1.26____________TEC_________TEH_________5_____HOT__________________U_____

52 82 0.57 73 P 3 TWD 23 DBH

-1.26 TEC TEH 5

HOT 600UL 56 82 0.59 117 P 3 TWD 24 DBH

-1.36 TEC TEH 5

HOT 600UL 62 82 0.29 125 P 3 TWD 14 DBH

-1.82 TEC TEH 5

HOT 600UL 94 82 0.61 147 P 2 TWD 22 09H

-0.26 TEH TEC 46 COLD 600UL 102 82 0.37 118 P 2 TWD 16 09H

+0.46 TEH TEC 45 COLD 600UL 0.26 79 P 3 TWD 10 DBH

+1.86 TER TEC 45 COLD 600UL 136 82 0.25 160 P 2 TWD 13 VH1

-0.87 TEC TEH 47 HOT 600UL 142__82__0.63__115__p_2_TWD__23______-0.90___________TEC________T_____________49_________OT____________________

142 82 0.63 115 P 2 TWD 23 VH2

-0.90 TEC TEH 49 HOT 600UL 144 82 0.16 105 P 3 TWD 7 DBC

+1.90 TEC TEH 49 HOT 600UL 0.24 87 P 3 TWD 11 DBH

+1.86 TEC TEH 49 HOT 600UL 51 83 0.25 48 P 3 TWD 16 DBH

-1.55 TEC TEH 6

HOT 600UL 0.40 65 P 3 TWD 22 DBC

-1.89 TEC TEH 6

HOT 600UL 53 83 0.66 100 P 3 TWD 26 DBC

-2.10 TEC TEH 5

HOT 600UL 57 83 0.24 52 P 3 TWD 12 DBC

-1.74 TEC TEH 5

HOT 600UL 0.16 26 P 3 TWD 9 DBC

+1.70 TEC TEH 5

HOT 600UL 61 83 0.43 112 P 3 TWD 23 DBC

+2.06 TEC TEH 6

HOT 600UL 63 83 0.33 53 P 3 TWD 15 DBC

+1.78 TEC TEH 5

HOT 600UL 85 83 0.27 130 P 2 TWD 13 06H

+0.81 TEH TEC 27 COLD 600UL 101 83 0.60 129 P 2 TWD 22 09H

-0.59 TEH TEC 46 COLD 600UL 131 83 0.32 80 P 2 TWD 16 VH1

-0.99 TEC TEH 47 HOT 600UL 141 83 0.60 112 P 2 TWD 22 VC1

+0.84 TEC TEH 49 HOT 600UL 143 83 0.16 107 P 3 TWD 9 DBC

+2.07 TEC TEH 47 HOT 600UL 145 83 0.43 124 P 3 TWD 18 DBC

+1.84 TEC TEH 49 HOT 600UL 54 84 0.20 87 P 3 TWD 10 DBC

-1.32 TEC TEH 5

HOT 600UL 58 84 0.64 80 P 3 TWD 29 DBH

+1.21 TEC TEH 6

HOT 600UL 60 84 0.22 10 P 3 TWD 12 DBH

+1.92 TEC TEH 5

HOT 600UL 74 84 0.34 79 P 3 TWD 16 DBC

-1.78 TEC TEH 5

HOT 600UL 94 84 0.44 63 P 2 TWD 18 08H

-0.35 TEH TEC 28 COLD 600UL 102 84 0.30 96 P 3 TWD 14 DBH

+1.60 TEH TEC 28 COLD 600UL 114 84 0.31 100 P 3 TWD 14 DBH

+1.89 TEH TEC 28 COLD 600UL 120 84 0.48 112 P 2 TWD 20 VH2

-0.80 TEH TEC 27 COLD 600UL 124 84 0.34 62 P 2 TWD 14 VH1

-1.10 TEH TEC 28 COLD 600UL 0.42 132 P 2 TWD 17 VH2

-1.05 TEH TEC 28 COLD 600UL 128 84 0.28 146 P 2 TWD 12 VH1

+0.94 TEH TEC 28 COLD 600UL 130 84 0.56 97 P 2 TWD 22 VHI

-0.77 TEH TEC 27 COLD 600UL 134 84 0.66 146 P 2 TWD 23 VH1

-0.84 TEC TEH 49 HOT 600UL 136 84 0.33 89 P 2 TWD 16 VH1

+0.50 TEC TEH 47 HOT 600UL 0.29 48 P 2 TWD 15 VHI

-0.91 TEC TEH 47 HOT 600UL

Framatome ANP Inc.

10/14/04 11:58:35 Customer Name: SONGS Unit 3 Component: S/G 88 MAI, MCI, MMI, MVI, SAI, SCI, SVI, 0-100% TWD QUERY: rpcicodes and_0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 53 85 0.39 70 P 3 TWD 18 DEC

-2.08 TEC TEH 0.37 135 P 3 TWD 17 DBH

-1.52 TEC TEH 0.87 52 P 3 TWD 30 DBH

+1.54 TEC TEH 55 85 0.52 77 P 3 TWD 26 DBH

+1.36 TEC TEH 57 85 0.40 41 P 3 TWD 18 DBH

+1.78 TEC TEH Page 15 of 28 61 85 0.40 65 85 0.24 73 85 0.18 75 85 0.24 95 85 0.42 0.34 97 85 0.29 101___85___0.45_

101 85 0.45 18 10 99 45 82 69 122 112 P 3 TWD P__3_TWO P 3 TWD P 3 TWD P 3 TWD P__2_TWO P 2 TWD P 2 TWD P 2 TWD P 2 TWD 18 15 12 12 18 16 13 18 DBH A

DBH A

DBC A

DBC 08H A

09H A

09H 09H

-2.02

+1.33

-1.81

-1.74

+0.86

-0.84

-0.14

-0.53 TEC TEC TEC TEC TEC TEH TEH TEH TEH TEH TEH TEH TEH TEC TEC TEC CAL F LEG PROBE 5

HOT 60_UL 5

HOT 600UL 5

HOT 600UL 6

HOT 600UL 5

HOT 600UL 5_____HOT____________________

6 HOT 600UL 6

HOT 600UL 5

HOT 600UL 7

HOT 600UL 27 COLD 600UL 27 COLD 600UL 28 COLD 600UL 28 COLD 600UL 103 85 0.34.

110 P 2 TWD 16 09H

+0.25 TEH TEC 27 COLD 600UL 137 85 0.08 152 P 2 TWD 4 09H

-1.04 TEC TER 49 HOT 600UL 0.25 121 P 2 TWD 11 09H

+0.89 TEC TEH 49 HOT 600UL 60 86 0.60 77 P 3 TWD 24 DBH

-1.76 TEC TEH 5

HOT 600UL 106 86 0.49 99 P 2 TWD 19 VH3

-0.88 TEH TEC 28 COLD 600UL 112 86 0.21 58 P 2 TWD 11 08H

+0.99 TER TEC 27 COLD 600UL 122 86 0.35 116 P 3 TWD 16 DBH

+1.91 TEH TEC 28 COLD 600UL 124 86 0.29 165 P 3 TWD 12 DBH

-0.14 TEH TEC 27 COLD 600UL 0.14 73 P 3 TWD 6 DBH

+1.83 TEH TEC 27 COLD 600UL 128 86 0.62 107 P 2 TWD 24 VH1

-0.82 TEH TEC 27 COLD 600UL 53 87 0.25 141 P 3 TWD 16 DBH

-1.61 TEC TER 6

HOT 600UL 55 87 0.57 77 P 3 TWD 23 DBH

-1.52 TEC TEH 5

HOT 600UL 103 87 0.48 102 P 2 TWD 19 09H

-0.04 TEH TEC 28 COLD 600UL 119 87 0.14 102 P 3 TWD 7 DBH

+0.69 TEH TEC 28 COLD 600UL 133 87 0.55 124 P 2 TWD 24 VH1

-0.79 TEC TER, 47 HOT 600UL 54__88__0.39___72_P__3_TWO___18_D__W_-1.48____________TEC_________TE__________5_____HOT________________________

54 88 0.39 72 P 3 TWD 18 DBH

-1.48 TEC TEH 5

HOT 600UL 58 88 0.36 62 P 3 TWD 16 DBH

-1.74 TEC TER 5

HOT 600UL 62 88 0.24 150 P 3 TWD 12 DBH

-1.62 TEC TEH 5

HOT 600UL 68 88 0.23 124 P 3 TWD 15 DBH

-1.51 TEC TER 6

HOT 600UL 94 88 0.31 97 P 2 TWD 13 09H

-0.80 TEH TEC 23 COLD 600UL 96 88 0.24 88 P 2 TWD 9 07H

+0.25 TEH TEC 24 COLD 600UL 104 88 0.38 104 P 2 TWD 14 08H

+0.50 TEH TEC 24 COLD 600UL 118 88 0.45 112 P 2 TWD 18 VH1

-0.63 TER TEC 23 COLD 600UL 130 88 0.33 74 P 2 TWD 15 VH1

+0.24 TER TEC 27 COLD 600UL 0.20 156 P 2 TWD 10 VH1

+0.75 TEH TEC 27 COLD 600UL 134 88 0.62 139 P 2 TWD 22 VH1

-0.82 TEC TEH 49 HOT 600UL 138 88 0.29 56 P 2 TWD 13 VHI

+0.71 TEC TEH 49 HOT 600UL 0.85 124 P 2 TWD 27 VH1

-0.78 TEC TEH 49 HOT 600UL 63 89___0_23___57_____________DEC_____________E___T____5__HOT_________

63 89 0.23 57 P 3 TWD 11 DBC

+2.14 TEC TER 5

HOT 600UL

Framatome ANP Inc.

10/14/04 11:58:35 Customer Name: SONGS Unit 3 Component: S/G 88 Page 16 of 28 MAI, MCI, MMI, MVI, SAI, SCI, SVI, 0-100% TWO QUERY: rpcicodes and_0-1001twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL I LEG PROBE 67 89 0.72 105 P 3 TWD 27 DBC

-1.90 TEC TEH 5

HOT 600UL,

69 89 0.52 143 P 3 TWO 26 DBC-

-1.45 TEC TEH 6

HOT 600UL 73 89 0.15 148 P 3 TWO 9 DBH

+1.61 TEC TEH 6

HOT 600UL 79 89 0.45 145 P 2 TWD 21 VH3

+0.72 TEC TEH 5

HOT 600UL 0.22 74 P 3 TWD 11 DBH

+1.64 TEC TEH 5

HOT 600UL 95___89 __0.36___132__P __2 __TWO __14 ________+_.57 TEH---T-----23---COL----D________________________________L 95 89 0.36 132 P 2 TWO 14 09H

+0.57 TEH TEC 23 COLD 600UL 99 89 0.72 110 P 2 TWO 25 09H

+0.72 TEH TEC 23 COLD 600UL 121 89 0.15 46 P 3 TWO 7 DBH

-1.11 TEH TEC 22 COLD 600UL 0.11 156 P 3 TWO 6 DBH

+0.23 TEH TEC 22 COLD 600UL 13189___0.20__110__P_2____O__________-0.93___________TE_____________________47_______HOT_______________________

131 89 0.20 110 P 2 TWO 11 VH1

-0.93 TEC TEH 47 HOT 600UL 137 89 0.32 123 P 2 TWO 16 VH1

+0.73 TEC TEH 47 HOT 600UL 0.18 135 P 2 TWO 10 VH1

-0.85 TEC TEH 47 HOT 600UL 143 89 0.23 128 P 2 TWD 10 08C

+0.91 TEC TEH 49 HOT 600UL 58 90 0.29 67 P 3 TWO 18 DBH

-1.46 TEC TEH 6

HOT 600UL 60 90 0.88 64 P 3 TWO 30 DBH

+1.60 TEC TEH 5

HOT 600UL 72 90 0.21 72 P 3 TWO 14 DBC

+1.97 TEC TEH 6

HOT 600UL 76 90 0.31 59 P 2 TWO 16 08C

-0.20 TEC TEH 6

HOT 600UL 116 90 0.23 142 P 3 TWD 11 DBH

+1.93 TEH TEC 22 COLD 600UL 134 90 0.18 144 P 2 TWO 8 VH1

+0.82 TEC TEH 49 HOT 600UL 53 91 0.95 108 P 3 TWD 31 DBH

-1.45 TEC TEH 5

HOT 600UL 0.16 66 P 3 TWO 9 DBH

+1.93 TEC TEH S

HOT 600UL 55 91 0.59 109 P 3 TWO 28 DBH

+1.30 TEC TEH 6

HOT 600UL 1.09 78 P 3 TWO 37 DBH

-1.54 TEC TEH 6

HOT 600UL 0.30 58 P 3 TWO 18 DBC

+2.02 TEC TEH 6

HOT 600UL 57 91 0.26 27 P 3 TWO 13 DBC

+1.85 TEC TEH 5

HOT 600UL 0.31 107 P 3 TWO 15 DBC

-2.09 TEC TEH 5

HOT 600UL 63 91 0.31 145 P 3 TWD 15 DBC

-1.87 TEC TEH 5

HOT 600UL 65 91 0.19 25 P 3 TWD 12 DBC

-1.75 TEC TEH 6

HOT 600UL 69 91 0.26 134 P 3 TWO 17 DBH

-1.48 TEC TEH 6

HOT 600UL 0.55 56 P 3 TWD 27 DBH

+1.68 TEC TEH 6

HOT 600UL 119 91 0.65 136 P 3 TWO 19 DBH

+1.98 TEH TEC 21 COLD 600UL 121 91 0.25 107 P 3 TWD 12 DBH

+2.05 TEH TEC 22 COLD 600UL 123 91 0.32 137 P 3 TWD 10 DBH

+1.98 TEH TEC 21 COLD 600UL 133 91 0.19 51 P 2 TWO 9 VH1

-0.91 TEC TEH 49 HOT 600UL 137 91 0.12 47 P 3 TWO 6 DBC

+1.68 TEC TEH 49 HOT 600UL 143 91 0.37 29 P 2 TWO 18 VC1

-0.85 TEC TEH 47 HOT 600UL 145 91 0.15 157 P 3 TWO 7 DBH

+1.99 TEC TEH 49 HOT 600UL 0.49 90 P 2 TWO 19 VC1

-0.84 TEC TEH 49 HOT 600UL 147 91 0.68 96 P 2 TWO 26 VC1

-0.90 TEH TEC 40 COLD 600UL 0.69 107 P 2 TWO 26 VC1

+0.53 TEH TEC 40 COLD 600UL 58 92 0.30 106 P 3 TWO 18 DBH

-1.68 TEC TEH 6

HOT 600UL 60 92 0.34 14 P 3 TWO 16 DBH

+2.05 TEC TEH 5

HOT 600UL

__02____92____0.29______139_____P___3__T___O___9___DEE_______1___92____TE_____TEC_____21____COLD-_____________L 102 92 0.29 139 P 3 TWO 9 DBH

+1.92 TEH TEC 21 COLD 600UL

Framatome ANP Inc.

10/14/04 11:58:35 Customer Name: SONGS Unit 3 Component: S/G 88 Page 17 of 28 MAI, MCI, MMI, MVI, SAI, SCI, SVI, 0-100% TWD QUERY: rpcicodes and 0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 110 92 0.35 75 P 2 TWD 15 09H

-1.15 TEH TEC 21 COLD 600UL 114 92 0.57 136 P 3 TWD 17 DBH

+1.89 TEH TEC 21 COLD 600UL 118 92 0.58 92 P 3 TWD 17 DBH

+1.96 TEH TEC 21 COLD 600UL 142 92 0.30 141 P 2 TWD 12 VH1

-0.91 TEC TEH 49 HOT 600UL 144 92 0.29 29 P 2 TWD 15 10C

-1.07 TEC TEH 52 HOT 600UL 146 92 0.38 69 P 2 TWD 17 VC1

+0.99 TEH TEC 40 COLD 600UL 0.41 114 P 2 TWD 18 10C

+0.56 TEH TEC 40 COLD 600UL 0.34 21 P 3 TWD 13 DEC

.+1.65 TEH TEC 40 COLD 600UL 57__93__0.80___92_P__3___WO__33_DBH__-1.27_______________EC_______TE__________6_____HOT________________________

57 93 0.80 92 P 3 TWD 33 DBH

-1.27 TEC TEH 6

HOT 600UL 59 93 0.45 79 P 3 TWD 20 DBH

-1.95 TEC TEH 5

HOT 600UL 99 93 0.45 122 P 2 TWD 19 09H

+0.50 TEH TEC 21 COLD 600UL 125 93 0.46 45 P 3 TWD 19 DBH

+1.80 TEH TEC 22 COLD 600UL 137 93 0.32 89 P 2 TWD 14 VH1

-0.95 TEC TEH 49 HOT 600UL 139 93 0.25 99 P 2 TWD 13 VC1

+0.87 TEC TEH 47 HOT 60OUL 141 93 0.38 100 P 2 TWD 15 VC1

+0.84 TEC TEH 49 HOT 600UL 145 93 0.29 98 P 2 TWD 16 VC1

-0.71 TEC TEH 52 HOT 600UL 0.42 110 P 3 TWD 19 DBC

+1.68 TEC TEH 52 HOT 600UL 147 93 0.54 142 P 2 TWD 24 VH2

-0.68 TEC TEH 53 HOT 600UL 68 94 0.50 107 P 3 TWD 26 DBH

-1.73 TEC TEH 6

HOT 600UL 74 94 0.23 97 P 3 TWD 11 DBH

-1.93 TEC TEH 5

HOT 600UL 86 94 0.29 99 P 2 TWD 8 01C

-0.92 TEH TEC 21 COLD 600UL 94 94 0.22 119 P 2 TWD 10 07H

+0.95 TEH TEC 21 COLD 600UL 106 94 0.27 134 P 2 TWD 12 VH2

-0.75 TEH TEC 21 COLD 600UL 114 94 0.28 151 P 3 TWD 9 DBH

-0.96 TEH TEC 21 COLD 600UL 134 94 0.22 133 P 2 TWD 10 VH1

+0.78 TEC TEH 49 HOT 600UL 0.31 141 P 2 TWD 14 VH1

-0.87 TEC TEH 49 HOT 600UL 138 94 0.30 65 P 2 TWD 15 VH1

+0.85 TEC TEH 47 HOT 600UL 142 94 0.26 149 P 2 TWD 14 VH2

-0.82 TEC TEH 52 HOT 600UL 0.17 35 P 2 TWD 9 VH1

+0.86 TEC TEH 52 HOT 600UL 0.19 135 P 2 TWD 11 VH1

-0.78 TEC TEH 52 HOT 600UL 53 95 0.37 55 P 3 TWD 21 DEC

-1.30 TEC TEH 6

HOT 600UL 101 95 0.47 90 P 2 TWD 20 09H

-0.21 TEH TEC 21 COLD 600UL 0.19 93 P 2 TWD 9 09H

+1.02 TEH TEC 21 COLD 600UL 123 95 0.77 137 P 2 TWD 27 VH1

+0.87 TEH TEC 20 COLD 600UL 145 95 0.09 18 P 3 TWD 6 DBC

-1.57 TEC TEH 53 HOT 600UL 56 96 0.31 30 P 3 TWD 15 DBC

+2.17 TEC TEH 5

HOT 600UL 62 96 0.53 107 P 3 TWD 26 DBC

+1.72 TEC TEH 6

HOT 600UL 94 96 0.12 19 P 2 TWD 5 08H

-0.49 TEH TEC 19 COLD 600DL 0.19 159 P 2 TWD 9 09H

+0.79 TEH TEC 19 COLD 600UL 114 96 0.51 160 P 3 TWD 21 DBH

+2.20 TEH TEC 19 COLD 600UL 124 96 0.21 73 P 3 TWD 12 DBH

+0.54 TEH TEC 20 COLD 600UL 0.48 47 P 3 TWD 22 DBH

+1.97 TEH TEC 20 COLD 600UL

Framatome ANP Inc.

10/14/04 11:58:35 Customer Name: SONGS Unit 3 Component: S/G 88 Page 18 of 28 MAI, MCI, MMI, MVI, SAI, SCI, SVI, 0-100% TWD QUERY: rpc icodesand 0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 126 96 0.30 134 P 2 TWD 14 VH1

-0.92 TEH TEC 19 COLD 600UL 128 96 0.53 136 P 2 TWD 21 VH2

-0.85 TEH TEC 20 COLD 600UL 132 96 0.14 106 P 2 TWD 8 VH1

+0.55 TEC TEH 47 HOT 600UL 0.38 109 P 2 TWD 18 VH1

-0.85 TEC TEH 47 HOT 600UL 134 96 0.41 135 P 2 TWD 16 VH1

-0.89 TEC TEH 49 HOT 600UL 144 96 0.70 95 P 2 TWD 28 VH1

+0.78 TEC TEH 52 HOT 600UL 0.23 23 P 2 TWD 13 VHI

+0.17 TEC TEH 52 HOT 600UL 0.30 54 P 3 TWD 15 DBH

+1.80 TEC TEH 52 HOT 600UL 146 96 0.58 39 P 3 TWD 27 DBC

+1.92 TEC TEH 53 HOT 600UL 55 97 0.67 103 P 3 TWD 26 DBH

-1.77 TEC TEH 5

HOT 600UL 0.60 9

P 3 TWD 24 DBH

+1.53 TEC TEH 5

HOT 600UL 85 97 0.45 90 P 2 TWD 19 09H

-1.23 TEH TEC 20 COLD 600UL 0.44 35 P 2 TWD 18 09H

+1.33 TEH TEC LOCOK 20 COLD 600UL 93 97 0.52 110 P 2 TWD 21 09H

-0.19 TEH TEC 20 COLD 600UL 0.20 148 P 2 TWD 10 09H

+0.85 TEH TEC 20 COLD 600UL 95 97 0.24 89 P 2 TWD 12 09H

-0.21 TEH TEC 19 COLD 600UL 101 97 0.67 119 P 2 TWD 24 09H

-0.96 TEH TEC 20 COLD 600UL 103 97 0.19 71 P 2 TWD 9 09H

-0.92 TEH TEC 19 COLD 600UL 0.19 113 P 2 TWD 9 09H

+0.81 TEH TEC 19 COLD 600UL 123 97 0.42 137 P 3 TWD 18 DBH

+1.38 TEH TEC 19 COLD 600UL 125 97 0.28 41 P 3 TWD 15 DBH

+1.66 TEH TEC 20 COLD 600UL 131 97 0.23 116 P 2 TWD 12 VH1

+0.83 TEC TEH 47 HOT 600UL 0.12 18 P 2 TWD 7 VH1

-0.87 TEC TEH 47 HOT 600UL 135 97 0.32 103 P 2 TWD 16 VH1

-0.93 TEC TEH 47 HOT 600UL 141 97 0.31 146 P 2 TWD 17 VH2

+1.05 TEC TEH 53 HOT 600UL 52 98 0.64 100 P 3 TWD 29 DBH

+1.60 TEC TEH 6

HOT 600UL 0.45 112 P 3 TWD 24 DBH

-1.54 TEC TEH 6

HOT 600UL 54 98 0.69 103 P 3 TWD 26 DBH

-2.05 TEC TEH 5

HOT 600UL 56 98 0.30 154 P 3 TWD 18 DBH

-1.65 TEC TEH 6

HOT 600UL 58 98 0.27 54 P 3 TWD 13 DBH

-1.72 TEC TEH 5

HOT 600UL 60 98 0.30 12 P 3 TWD 18 DBH

+1.95 TEC TEH 6

HOT 600UL 84 98 0.24 103 P 2 TWD 12 09H

-1.36 TEH TEC LOCOK 19 COLD 600UL 86 98 0.21 63 P 2 TWD 10 06H

+0.86 TEH TEC 20 COLD 600UL 88 98 0.25 92 P 2 TWD 12 09H

-1.07 TEH TEC 19 COLD 600UL 92 98 0.50 129 P 2 TWD 22 08H

-0.57 TEH TEC 19 COLD 600UL 96 98 0.38 119 P 2 TWD 18 09H

+0.67 TEH TEC 19 COLD 600UL 142 98 0.33 116 P 2 TWD 18 VHI

+0.76 TEC.TEH 53 HOT 600UL 51 99 0.37 54 P 3 TWD 17 DBH

-1.49 TEC TEH 5

HOT 600UL 0.40 6

P 3 TWD 18 DBH

+1.59 TEC TEH 5

HOT 600UL 55 99 0.36 93 P 3 TWD 17 DBH

-1.67 TEC TEH 5

HOT 600UL 59 99 0.19 112 P 3 TWD 9 DBH

-1.77 TEC TEH 5

HOT 600UL 87 99 0.31 163 P 2 TWD 15 07H

+0.97 TEH TEC 19 COLD 600UL 0.15 114 P 2 TWD 7 08H

-0.45 TEH TEC 19 COLD 600UL 0.22 99 P 2 TWD 10 09H

+0.97 TEH TEC 19 COLD 600UL

Framatome ANP Inc.

Customer Name: SONGS Unit 3 MAI, MCI, MMI, MVI, SAI, SCI, SVI, 0-100% TWD 10/14/04 11:58:35 Component: SIG 86 Page 19 of 28 QUERY: rpc icodes and 0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 91_ 99-- 0.27-- 16 P 2 =TW 13

+0.90 T---TEC 19 COLD

==

0UL 91 99 0.27 106 P 2 TWD 13 08H

+0.90 TEH TEC 19 COLD 600UL 0.26 48 P 2 TWD 13 08H

-0.59 TEH TEC 19 COLD 600DL 99 99 0.39 93 P 2 TWD 18 09H

-0.15 TEH TEC 19 COLD 600UL 113 99 0.22 157 P 3 TWD 12 DBH

+2.14 TEH TEC 20 COLD 600UL 125 99 0.33 37 P 3 TWD 16 DBH

+0.81 TEH TEC 20 COLD 600UL 0.37 125 P 3 TWD 18 DBH

+1.78 TEH TEC 20 COLD 600UL 129 99 0.55 96 P 2 TWD 21 10H

-0.25 TEH TEC 20 COLD 600UL 143 99 0.14 63 P 3 TWD 8 DBC

+1.66 TEC TEH 52 HOT 600UL 145 99 0.52 129 P 2 TWD 24 VH2

+0.88 TEC TEH 53 HOT 600UL 0.25 142 P 2 TWD 14 08H

+0.77 TEC TEH 53 HOT 600UL 0.78 136 P 2 TWD 30 VH3

+0.78 TEC TEH 53 HOT 600UL 0.27 64 P 2 TWD 15 VH3

+0.16 TEC TEH 53 HOT 600UL 0.30 20 P 3 TWD 17 DBC

+1.98 TEC TEH 53 HOT 600UL 44 100 0.75 71 P 3 TWD 32 DBH

-1.49 TEC TEH 6

HOT 600UL 0.26 103 P 3 TWD 17 DBH

+1.59 TEC TEH 6

HOT 600UL 46 100 0.59 24 P 3 TWD 24 DBH

+1.62 TEC TEH 5

HOT 600UL 50 100 0.61 76 P 3 TWD 29 DBH

-1.55 TEC TEH 6

HOT 600UL 56 100 0.20 144 P 2 TWD 11 VSM

-0.85 TEC TEH 5

HOT 600UL 82 100 0.33 101 P 2 TWD 16 VH3

-0.84 TER TEC 19 COLD 600UL 0.29 45 P 2 TWD 14 VH3

+0.73 TEH TEC 19 COLD 600UL 84 100 0.67 119 P 2 TWD 24 09H

-1.50 TEH TEC LOCOK 20 COLD 600UL 0.36 81 P 2 TWD 16 09H

+1.52 TEH TEC LOCOK 20 COLD 60ODUL 100 100 0.46 142 P 2 TWD 19 09H

+0.85 TEH TEC 20 COLD 600UL 106 100 0.35 131 P 2 TWD 17 09H

-0.88 TEH TEC 19 COLD 600UL 126 100 0.32 88 P 2 TWD 15 VH1

-0.94 TEH TEC 19 COLD 600UL 128 100 0.58 133 P 2 TWD 22 VH1

-0.89 TEH TEC 20 COLD 600UL 132 100 0.46 133 P 2 TWD 21 VH1

-0.87 TEC TEH 47 HOT 600UL 136 100 0.28 123 P 2 TWD 15 VH1

-0.88 TEC TEH 52 HOT 600UL 0;41 93 P 2 TWD 20 VH2

-1.10 TEC TEH 52 HOT 600UL 146 100 0.26 52 P 2 TWD 15 10C

+0.00 TEC TEH 53 HOT 600UL 0.23 101 P 2 TWD 13 08C

-0.23 TEC TEH 53 HOT 600UL 0.49 110 P 2 TWD 23 10C

+0.84 TEC TEH 53 HOT 600UL 0.25 84 P 2 TWD 14 VC2

-0.90 TEC TEH

53.

HOT 600UL 45 101 0.54 16 P 3 TWD 22 DBH

+1.17 TEC TEH 5

HOT 600UL 0.14 39 P 3 TWD 7 DBH

-1.77 TEC TEH 5

HOT 600UL 0.34 73 P 3 TWD 16 DBC

-1.85 TEC TEH 5

HOT 600UL 47 101 0.51 85 P 3 TWD 26 DBH

-1.86 TEC TEH 6

HOT 600UL 0.30 85 P 3 TWD 18 DBC

-1.93 TEC TEH 6

HOT 600UL 49 101 0.36 118 P 3 TWD 16 DBH

-1.51 TEC TEH 5

HOT 600UL 83 101 0.15 109 P 2 TWD 7 07H

-0.64 TEH TEC 19 COLD 600UL 87 101 0.26 107 P 2 TWD 13 07H

+0.19 TEH TEC 19 COLD 600UL 89 101 0.41 149 P 2 TWD 17 07H

+0.95 TEH TEC 20 COLD 600UL 95 101 0.50 92 P 2 TWD 22 09H

-0.48 TEH TEC 19 COLD 600UL 0.17 36 P 2 TWD 8 09H

+0.69 TEH TEC 19 COLD 600UL 99 101 0.32 125 P 2 TWD 15 08H

-0.32 TEH TEC 19 COLD 600UL 0.33 122 P 2 TWD 16 09H

+0.71 TEH TEC 19 COLD 600UL 0.32 122 P 3 TWD 14 DBH

+1.34 TEH TEC 19 COLD 600UL 101 101 0.37 103 P 2 TWD 16 09H

-0.21 TEH TEC 20 COLD 600UL

Framatome ANP Inc.

10/14/04 11:58:35 Customer Name: SONGS Unit 3 Component: S/G 88 Page 20 of 28 MAI, MCI, MMI, MVI, SAI, SCI, SVI, 0-100% TWD QUERY: rpcicodes and_0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 105 101 0.28 131 P 2 TWD 13 VH2

+0.40 TEH TEC 20 COLD 600UL 133 101 0.29 151 P 2 TWD 16 VH1

-0.95 TEC TEH 52 HOT 600UL 0.55 124 P 2 TWD 24 10H

-1.03 TEC TEH 52 HOT 600UL 143 101 0.27 75 P 2 TWD 15 VC1

-0.89 TEC TEH 52 HOT 600UL 0.13 151 P 3 TWD 7 DBC

+1.96 TEC TEH 52 HOT 600UL 44 102 0.32 78 P 3 TWD 13 DBC

+1.44 TEH TEC 11 COLD 600UL 48 102 0.39 113 P 3 TWD 16 DBH

-1.71 TEH TEC 12 COLD 600UL 80 102 0.74 68 P 2 TWD 28 VC3

-0.86 TEA TEC 11 COLD 600UL 84 102 0.31 29 P 2 TWD 14 09H

-1.44 TEA TEC LOCOK 45 COLD 600UL 0.40 137 P 2 TWD 17 07H

-0.88 TEA TEC 45 COLD 600UL 86 102 0.45 160 P 2 TWD 18 09H

+0.63 TEH TEC 17 COLD 600UL 90 102 0.46 103 P 2 TWD 18 08H

+0.88 TEA TEC 17 COLD 600UL 0.24 145 P 2 TWD 11 09H

+0.08 TEA TEC 17 COLD 600UL 92 102 0.52 62 P 2 TWD 20 09H

+0.97 TER TEC 18 COLD 600UL 94__102__0.32__94_P__2_T__D_14__0911_-0.36___________TEA________TEC________17______COLD________________________

94 102 0.32 94 P 2 TWD 14 09H

-0.36 TER TEC 17 COLD 600UL 100 102 0.39 115 P 2 TWD 15 09H

-0.29 TER TEC 1S COLD 600UL 134 102 0.35 149 P 2 TWD 18 VH2

+0.80 TEC TEA 52 HOT 600UL 0.24 99 P 2 TWD 13 VH2

-0.86 TEC TEH 52 HOT 600UL 144 102 0.36 72 P 2 TWD 19 VC3

+0.77 TEC TEH 53 HOT 600UL 0.21 44 P 3 TWD 13 DBH

+1.88 TEC TEH 53 HOT 600UL 41 103 0.44 95 P 3 TWD 18 DBH

+1.66 TER TEC 12 COLD 600UL 0.26 134 P 3 TWD 12 DBH

-1.65 TEH TEC 12 COLD 600UL 47 103 1.18 97 P 2 TWD 36 VSM

-0.77 TER TEC 11 COLD 600UL 91 103 0.47 131 P 2 TWD 19 08H

+0.84 TEH TEC 17 COLD 600UL 95 103 0.33 57 P 2 TWD 14 09H

+0.88 TER TEC 17 COLD 600UL 97 103 0.66 127 P 2 TWD 23 09H

+0.31 TEH TEC 18 COLD 600UL 99 103 0.15 139 P 2 TWD 7 09H

+0.27 TEA TEC 17 COLD 600UL 0.62 98 P 2 TWD 23 09H

+0.92 TER TEC 17 COLD 600UL 127 103 0.56 149 P 2 TWD 21 VH1

-0.90 TEH TEC 17 COLD 600UL 0.78 82 P 2 TWD 26 VH1

+1.02 TEH TEC 17 COLD 600UL 131 103 1.03 69 P 2 TWO 34 VC3

-0.82 TEC TER 52 HOT 600UL 137 103 0.62 77 P 2 TWO 26 VH1

-0.91 TEC TEH 52 HOT 600UL 0.34 49 P 2 TWD 17 VH1

+0.74 TEC TEH 52 HOT 600UL 38 104 0.29 84 P 3 TWD 13 DBH

-1.55 TEA TEC 12 COLD 600UL 40____104_____0.78_____135_____P___2___T___D__28____VS______+0.90______TEA_____TEC__________COLD____________U__

40 104 0.78 135 P 2 TWD 28 VSM

+0.90 TEH TEC 11 COLD 600UL 48 104 0.56 105 P 2 TWD 23 VSM

+0.88 TEA TEC 11 COLD 600UL 88 104 0.36 132 P 2 TWD 14 VH2

-0.85 TER TEC 46 COLD 600UL 92 104 0.30 50 P 2 TWD 13 09H

+0.23 TEH TEC 17 COLD 600UL 94 104 0.26 95 P 3 TWD 13 DBH

+1.25 TEA TEC 18 COLD 600UL 126 104 0.51 154 P 2 TWD 20 VH1

-0.92 TEA TEC 17 COLD 600UL 142 104 0.30 134 P 3 TWD 17 DBH

+2.01 TEC TEA 53 HOT 600UL 37 105 0.46 42 P 3 TWD 18 DBH

+1.92 TEH TEC 11 COLD 600UL 87__105__0.22___63__P3_TW____8_0__11_-2.01___________TEA___________EC______45______COLD________________________

87 105 0.22 63 P 3 TWD 8 DBH

-2.01 TER TEC 45 COLD 600UL

Framatome ANP Inc.

10/14/04 11:58:35 I

Customer Name: SONGS Unit 3 Component: S/G 88 Page 21 of 28 MAI, MCI, MMI, MVI, SAI, SCI, SVI, 0-100% TWD QUERY: rpc icodes and_0-100%twd.qry ROW LINE VOLTS DEG CHN-IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL t LEG PROBE 91 105 0.62 134 P 2 TWD 23 09H

-0.17 TEH TEC 17 COLD 600UL 93 105 0.35 125 P 2 TWD 14 08H

-0.50 TER TEC 18 COLD 600UL 95 105 0.70 134 P 2 TWD 25 09H

+0.82 TEH TEC 17 COLD 600UL 0.22 38 P 3 TWD 9 DBH

+0.79 TEH TEC 17 COLD 600UL 105 105 0.32 111 P 2 TWD 13 VH2

-0.52 TEH TEC 18 COLD 600UL 143 105 0.33 64 P 3 TWD 18 DBH

-1.69 TEC TEH 53 HOT 600UL 0.39 132 P 3 TWD 21 DBC

+1.61 TEC TEH 53 HOT 600UL 0.29 15 P 3 TWD 16 DBH

+1.78 TEC TEH 53 HOT 600UL 32 106 0.32 92 P 2 TWD 16 04C

+0.86 TEH TEC 11 COLD 600UL 38 106 0.19 63 P 2 TWD 8 VSM

+0.19 TEH TEC 12 COLD 600UL 0.32 109 P 2 TWD 13 VSM

+1.03 TEH TEC 12 COLD 600UL 48 106 0.55 78 P 2 TWD 23 VSM

+0.84 TEH TEC 11 COLD 600UL 0.39 65 P 2 TWD 18 VSM

-0.73 TEH TEC 11 COLD 600UL 0.62 85 P 2 TWD 25 VSM

-0.11 TEH TEC 11 COLD 600UL 84 106 0.39 95 P 2 TWD 15 09H

-1.46 TEH TEC LOCOK 46 COLD 600UL 0.70 117 P 2 TWD 24 09H

+1.56 TEH TEC LOCOK 46 COLD 600UL 98 106 0.38 144 P 2 TWD 16 09H

+0.99 TEH TEC 17 COLD 600UL 0.28 46 P 2 TWD 13 09H

-0.10 TEH TEC 17 COLD 600UL 102 106 0.26 98 P 2 TWD 12 04C

+0.88 TEH TEC 17 COLD 600UL 126 106 0.51 120 P 2 TWD 20 VH1

-0.48 TEH TEC 17 COLD 600UL 128__106 __0 _52 __137_P_2__T _D _20 ______

0.92__________TE_________

T__________17______COLD____

=----------------L--

128 106 0.52 137 P 2 TWD 20 VH1

-0.92 TEH TEC 17 COLD 600UL 130 106 0.44 135 P 2 TWD 18 VHI

-0.83 TEH TEC 18 COLD 600UL 0.29 108 P 2 TWD 13 VHl

-0.14 TEH TEC 18 COLD 600UL 136 106 0.51 26 P 2 TWD 23 VH2

-1.20 TEC TEH 52 HOT 600UL 140 106 0.16 91 P 3 TWD 10 DBH

+1.36 TEC TEH 53 HOT 600UL 29 107 0.31 58 P 3 TWD 12 DBH

-1.70 TEH TEC 11 COLD 600UL 35 107 0.41 141 P 2 TWD 16 VSM

-0.86 TEH TEC 12 COLD 600UL 0.35 145 P 2 TWD 14 VSM

+0.00 TEH TEC 12 COLD 600UL 73 107 0.29 124 P 2 TWD 12 VH3

-0.79 TEH TEC 12 COLD 600UL 0.69 119 P 2 TWD 24 VH3

+0.88 TEH TEC 12 COLD 600UL 81 107 0.34 69 P 3 TWD 14 DBH

-1.93 TEH TEC 46 COLD 600UL 97 107 0.59 101 P 2 TWD 22 09H

+0.OZ TEH TEC 17 COLD 600UL 0.64 67 P 2 TWD 23 09H

-0.63 TEH TEC 17 COLD 600UL 111 107 0.67 100 P 2 TWD 24 VH2

-0.80 TEH TEC 17 COLD 600UL 115 107 0.12 10 P 3 TWD 5 DBH

+2.24 TEH TEC 17 COLD 600UL 24__108__0.66__ 119_ _P _2 _T __D_23 0.51_____

_____TEE_____ T ___________12______COLD_______________________

24 108 0.66 119 P 2 TWD 23 VSM

-0.51 TEH TEC 12 COLD 600UL

0. 1 1 2 P 2 TDVS

=--------------------

0.09-

=---E---------

TEC----------12--------COLD-------------__

36 108 0.51 104 P 2 TWD 19 VSM

-0.91 TEH TEC 12 COLD 600UL 0.51 122 P 2 TWD i9 VSM

-0.09 TEH TEC 12 COLD 600UL 44 108 0.77 120 P 2 TWD 25 VSM

-0.54 TEH TEC 12 COLD 600UL 0.68 118 P 2 TWD 23 VSM

+0.11 TEH TEC 12 COLD 600UL 48 108 0.39 133 P 2 TWD 15 VSM

-0.58 TEH TEC 12 COLD 600UL 84 108 0.42 143 P 2 TWD 17 09H

-1.72 TEH TEC LOCOK 18 COLD 600UL 0.41 123 P 2 TWD 17 09H

+1.51 TEH TEC LOCOK 18 COLD 600UL 86 108 0.66 75 P 2 TWD 24 VH2

-0.32 TEH TEC 17 COLD 600UL 102 108 0.45 66 P 2 TWD 18 VH2

-0.78 TEH TEC 17 COLD 600UL

Framatome ANP Inc.

10/14/04 11:58:35 Customer Name: SONGS Unit 3 Component: S/G 88 Page 22 of 28 MAI, MCI, MMI, MVI, SAI, SCI, SVI, 0-100% TWD QUERY: rpc icodes and 0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 126 108 0.30 109 P 2 TWD 13 VH1

+0.27 TEH TEC 17 COLD 600UL 0.57 136 P 2 TWD 22 VH1

-0.97 TEH TEC 17 COLD 600UL 136 108 0.34 91 P 2 TWD 18 VHI

+0.70 TEC TEH 52 HOT 600UL 0.44 135 P 2 TWD 21 VHI

-0.93 TEC TEH 52 HOT 600UL 142 108 0.28 136 P 2 TWD 16 VH3

+0.82 TEC TEH 53 HOT 600UL 0.30 137 P 2 TWD 16 VH2

-1.07 TEC TEH 53 HOT 600UL 0.23 133 P 2 TWD 13 VHI

-0.92 TEC TEH 53 HOT 600UL 17 109 0.29 69 P 3 TWD 13 DBC

-2.00 TEH TEC 12 COLD 600UL 47__109__0.33__69__P_2__TWD__16__V___-0.13___________TEH________TE_________________COLD___________________U____

47 109 0.33 69 P 2 TWD 16 VSM

-0.13 TEH TEC 11 COLD 600UL 89 109 0.33 67 P 2 TWD 14 08H

+0.82 TEH TEC 17 COLD 600UL 0.24 127 P 2 TWD 11 09H

+0.61 TEH TEC 17 COLD 600UL

=_ --

95 109 0.25 52 P 2 TWD 14 09H

+0.82 TEH TEC 17 COLD 600UL 99 109 0.22 144 P 2 TWD 10 09H

+0.78 TEH TEC 17 COLD 600UL 117 109 0.35 125 P 2 TWD 14 VH2

-0.81 TEH TEC 18 COLD 600UL 121 109 0.26 77 P 2 TWD 11 10H

-1.12 TEH TEC 18 COLD 600UL 44 110 0.50 83 P 2 TWD 22 VSM

+0.82 TEH TEC 11 COLD 600UL 82 110 0.41 40 P 2 TWD 17 VH3

+0.83 TEH TEC 18 COLD 600UL 84 110 0.20 52 P 2 TWD 9 08H

+0.11 TEH TEC 17 COLD 600UL 0.72 135 P 2 TWD 25 09H

-1.72 TEH TEC LOCOR 17 COLD 600UL 0.78 117 P 2 TWD 26 09H

+1.49 TEH TEC LOCOK 17 COLD 600UL 96 110 0.26 100 P 2 TWD 10 09H

+0.19 TEH TEC 18 COLD 600UL 122 110 0.36 146 P 2 TWD 15 VH1

-0.76 TEH TEC 17 COLD 600UL 124 110 0.58 108 P 2 TWD 21 VHC

-0.19 TEH TEC 18 COLD 600UL 134 110 0.51 139 P 2 TWD 23 VH1

-0.86 TEC TEC 52 HOT 600UL 142 110 0.17 57 P 3 TWD 11 DBH

+2.12 TEC TEC 53 HOT 600UL 73 111 0.29 122 P 2 TWD 13 VSM

-0.69 TEH TEC 10 COLD 600UL 0.44 146 P 2 TWD 18 VSM

+0.79 TEH TEC 10 COLD 600UL 81 111 0.41 119 P 2 TWD 17 VH3

+0.90 TEH TEC 17 COLD 600UL 0.95 124 P 2 TWD 30 VC3

-0.73 TEH TEC 17 COLD 600UL 0.49 108 P 2 TWD 19 VC3

+0.90 TEH TEC 17 COLD 600UL 87 111 0.25 104 P 2 TWD 11 08H

-0.38 TEH TEC 17 COLD 600UL 91 111 0.43 55 P 2 TWD 17 09H

+0.65 TEH TEC 17 COLD 600UL 93 112 0.45 122 P 2 TWD 18 08H

+0.31 TEH TEC 18 COLD 600UL 95 111 0.38 78 P 2 TWD 16 09H

+0.86 TEH TEC 17 COLD 600UL 101 111 0.37 45 P 2 TWD 16 VH2

+0.80 TEH TEC 17 COLD 600UL 86__112__0.39__40__P_2__TWO__15______-0.21________________H________________18______COLD________________________

127 111 0.38 112 P 2 TWD 16 VH1

-0.85 TEH TEC 18 COLD 600UL 139 Ill 0.26 67 P 3 TWD 13 DBH

+1.80 TEC TEH 52 HOT 600UL 18 112 0.44 12 2

SAI TSH

-1.28 TSH TSH 0.14 19.00 89 HOT 580PP 0.36 11 2

SAI TSH

-1.56 TSH TSH 0.12 19.00 89 HOT 580PP 34 112 0.33 32 P 2 TWD 15 VSM

+0. 65 TEH TEC 9

COLD 600UL 36 112 0.34 93 P 2 TWD 14 VSM

-0.75 TEH TEC 10 COLD 600UL 0.74 132 P 2 TWD 25 VSM

+0.73 TEH TEC 10 COLD 600UL 48 112 0.59 91 P 2 TWD 22 VSM.02 TEH TEC 10 COLD 600UL 1.21 91 P 2 TWD 33 VSM

+0. 83 TEH TEC.

10 COLD 600UL 86 112 0.39 40 P 2 TWD 15 08H

-0.21 TEH TEC 18 COLD 600UL

Framatome ANP Inc.

10/14/04 11-58:35 Customer Name: SONGS Unit 3 Component: S/G 88 Page 23 of 28 MAl, MCI, MMI, MVI, SAI, SCI, SVI, 0-100% TWD QUERY: rpc icodesand_0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL. I UTIL 2 CAL # LEG PROBE 92 112 0.70 101 P 2 TWD 25 09H

+0.23 TEH TEC 17 COLD 600UL 0.28 100 P 2 TWD 13 09H

+0.82 TEH TEC 17 COLD 600UL 112__112 _0.54__ 124__P_2_TW___21 _____

0.75_

T-------_

_TEC----------17_______COLD____

112 112 0.54 124 P 2 TWD 21 VH2

-0.75 TEH TEC 17 COLD 600UL 118 112 0.37 108 P 2 TWD 15 VH2

-0.85 TEH TEC 18 COLD 600UL

___________0.49

__73 __P _2 __TWD 19 -------

- 0.91----

T--------------TEC 18------ COLD------------__

122 112 0.37 112 P 2 TWD 15 VH1

+0.75 TEH TEC 18 COLD 600UL 0.49 73 P 2 TWD 19 VH2

-0.91 TEH TEC 18 COLD 600UL 124 112 0.79 112 P 2 TWD 26 VH1

+0.75 TEH TEC 17 COLD 600UL 136 112 0.47 79 P 2 TWD 22 VH2

-1.24 TEC TEH 53 HOT 600UL 1

113 0.40 125 P 2 TWD 20 04H

+0.77 07H TEH LAR 40 HOT 600UL 47 113 0.48 77 P 2 TWD 20 VSM

-0.90 TEH TEC 7

COLD 600UL 0.60 103 P 2 TWD 24 VSM

-0.02 TEH TEC 7

COLD 600UL 0.93 112 P 2 TWD 31 VSM

+0.82 TEH TEC 7

COLD 600UL 0.17 154 P 3 TWD 8 DBC

-1.68 TEH TEC 7

COLD 600UL 73 113 0.43 73 P 2 TWD 17 02H

-1.24 TEH TEC 8

COLD 600UL 77 113 0.28 93 P 2 TWD 12 VSM

+0.89 TEH TEC 8

COLD 600UL 0.17 109 P 3 TWD 8 DBC

+1.87 TEH TEC 8

COLD 600UL 0.45 111 P 2 TWD 18 VH3

+0.87 TEH TEC 8

COLD 600UL 0.25 107 P 2 TWD 11 VSM

-0.02 TEH TEC 8

COLD 600UL 81 113 0.55 91 P 2 TWD 21 08C

-0.26 TEH TEC 17 COLD 600UL 1.02 113 P 2 TWD 31 VSM

-0.61 TEH TEC 17 COLD 600UL 0.29 121 P 2 TWD 13 VC3

+0.84 TEH TEC 17 COLD 600UL 89 113 0.49 123 P 2 TWD 19 09H

+0.53 TEH TEC 17 COLD 600UL 91 113 0.29 105 P 2 TWD 12 09H

-0.39 TEH TEC 18 COLD 600UL 0.54 96 P 2 TWD 20 09H

+0.50 TEH TEC 18 COLD 600UL 93 113 0.37 72 P 2 TWD 16 09H

+0.61 TEH TEC 17 COLD 600UL 105 113 0.39 108 P 2 TWD 16 VH2

-0.73 TEH TEC 17 COLD 600UL 141 113 0.28 158 P 2 TWD 15 09C

+0.88 TEC TEH 53 HOT 600UL 10 114 1.22 34 P 1 MCI TSH

-17.95 TSH TSH 0.57 19.64 60 HOT 580PP 0.43 22 P 1 SCI TSH1 V

-12.25 TSH TSH 0.14 19.64 60 HOT 580PP 70 114 0.30 110 P 2 TWD 13 07H

-0.76 TEH TEC 8

COLD 600UL 76 114 0.55 97 P 2 TWD 22 VH3

+0.63 TEH TEC 71 COLD 600UL 0.39 136 P 2 TWD 18 VC3

+0.84 TEH TEC 7

COLD 600UL 0.31 107 P 2 TWD 15 VSM

-0.71 TEH TEC 7

COLD 600UL 84 114 0.38 122 P 2 TWD 15 09H

+1.89 TEH TEC LOCOK 15 COLD 600UL 0.51 131 P 2 TWD 20 09H

-1.41 TEH TEC IOCOK 15 COLD 600UL 86 114 0.39 74 P 2 TWD 16 VH2

-0.67 TEH TEC 16 COLD 600UL 120 114 0.31 100 P 3 TWD 14 D8H

+0.42 TEH TEC 16 COLD 600UL 122 114 0.24 81 P 2 TWD 9 VH1

+0.55 TEH TEC 15 COLD 600UL 126 114 0.36 122 P 2 TWD 14 VH1

+0.80 TEH TEC 15 COLD 600UL 43 115 0.58 139 P 2 TWD 23 VSM

+0.76 TEH TEC 7

COLD 600UL 79 115 0.46 149 P 2 TWD 20 VH3

+0.86 TEH TEC 7

COLD 600UL 0.46 71 P 2 TWD 19 VC3

-0.86 TEH TEC 7

COLD 600UL 91 115 0.28 124 P 2 TWD 12 09H

+0.29 TEH TEC 16 COLD 600UL 125 115 0.41 144 P 2 TWD 16 VH1

+0.63 TEH TEC 15 COLD 600UL 127 115 0.42 110 P 2 TWD 17 VH1

+0.83 TEH TEC 16 COLD 600UL 78 116 0.48 99 P 2 TWD 19 02H

-0.45 TEH TEC 8

COLD 600UL

Framatome ANP Inc.

Customer Name: SONGS Unit 3 MAI, MCI, MMI, MVI, SAI, SCI, SVI, 0-100% TWD QUERY: rpc icodes and 0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION 10/14/04 11:58:35 Component: S/G 88 Page 24 of 28 EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 84 116 0.47 101 P 2 TWD 19 09H

-1.54 TEH TEC LOCOK 15 COLD 600UL 0.56 141 P 2 TWD 21 09H

+1.35 TEH TEC LOCOK 15 COLD 600UL 86 116 0.40 96 P 2 TWD 16 09H

-1.10 TEH TEC 16 COLD 600UL 102__11__0.46__128__P_2_TW___18_____-0.91_________TE_____

TEC----------16-------COLD--------------------UL----

102 116 0.46 128 P 2 TWD 18 VH2

-0.91 TEH TEC 16 COLD 600UL 124 116 0.65 139 P 2 TWD 24 VH1

-0.77 TEH TEC 16 COLD 600UL 79 117 0.29 137 P 2 TWD 14 07H

-0.77 TEH TEC 7

COLD 600UL 0.73 110 P 2 TWD 27 VC3

-0.92 TEH TEC 7

COLD 600UL 0.81 121 P 2 TWD 28 VC3

+0.80 TEH TEC 7

COLD 600UL 83____11______0.33______80____P___2__________14____01________0.90______TE_______EC____16____COLD____________UL_

83 117 0.33 80 P 2 TWD 14 01H

+0.90 TEH TEC 16 COLD 600UL 0.30 146 P 2 TWD 12 05C

+0.50 TEH TEC 16 COLD 600UL 87 117 0.39 124 P 2 TWD 16 09H

+0.31 TEH TEC 16 COLD 600UL 113_____117_____0.19______36____P___3____W_____8___D___W___+1.89_______TEH______EC____15____COLD____________UL_

113 117 0.19 36 P 3 TWD 8 DBH

+1.89 TEH TEC 15 COLD 600UL 46 118 0.19 89 P 2 TWD 10 07H

+0.39 TEH TEC 7

COLD 600UL 74____118_____0.51______97____P___2___TWO_____21____0_______+0.95_______TEH_____TEC_____7___COLD____________UL_

74 118 0.51 97 P 2 TWD 21 08H

+0.95 TEH TEC 7

COLD 600UL 84 118 0.46 130 P 2 TWD 19 09H

-1.20 TEH TEC 15 COLD 600UL 96 116 122 126 130 132 136 127 118 118 118 118 118 118 118 119 0.40 0.33 0.43 0.40 0.44 0.09 0.12 0.35 108 106 59 153 120 107 14 139 P 2 TWD 16 P_2_TWO_14 P 2 TWD 14 P _ 2 _ T W O _ 1 6 P 2 TWD 17 P 2 TWD 16 P 3_ T W_ 8_

P 2 TWD 18 P 3 TWD 4 P 3 TWD 8 P 2 TWD 14 VH2 VH1 VH2 VH1 VH2 DBH DBH VH1

-0.93

- 0.8 5_

-0.86

+0.78_

-0.86

+0.78

-0.88

+1.77

+1.49

-1.00 TEH TEC

_ E T EC__

TEW TEC TE____TEC TEH TEC TEC TEC TEC___TE_

TEH TEC TEC TEH TEC TEH TEH TEC COLD 600UL COLD 600UL COLD 600UL COLD__________L COLD 600UL COLD 600UL HOT 600UL HOT 600UL COLD 600UL l-<

s N

- z z

b------------

86 120 0.42 66 P 2 TWD 17 VH2

-0.65 TEH TEC 16 COLD 600UL 106 120 0.19 76 P 3 TWD 9 DBC

+1.56 TEW TEC 16 COLD 600UL 120 120 0.36 108 P 2 TWD 14 lOW

-1.65 TEA TEC LOCOK 15 COLD 600UL 124 120 0.52 107 P 2 TWD 20 VH2

-0.76 TEW TEC 15 COLD 600UL 35 121 0.39 119 P 2 TWD 17 05H

+0.81 TER TEC 5

COLD 600UL 75 121 0.22 109 P 2 TWD 11 VH3

-0.79 TEH TEC 5

COLD 600UL 81 121 0.45 154 P 2 TWD 18 VH3

+0.83 TEH TEC 16 COLD 600UL 0.69 105 P 2 TWD 24 VH3

-0.81 TEH TEC 16 COLD 600UL 40 122 0.27 88 P 2 TWD 12 07H

-0.45 TEH TEC 6

COLD 600UL 58 122 0.31 36 P 2 TWD 14 02H

-1.19 TEW TEC 5

COLD 600UL 84 122 0.43 127 P 2 TWD 18 09H

-1.55 TEH TEC LOCOK 16 COLD 600UL 112 122 0.56 71 P 2 TWD 21 04C

-0.91 TEH TEC 15 COLD 600UL 2 3 _ _ 1 2 3 _ 0. 3 6_

1 23_

P_ 2_ T W O_ 1 0 7W

+ 0.3 5 T EW__

_ _ _ _ _ _ _ _ _ _T EC__

_ _ _ _ _ _ _ _ _ _5__ _ _ _ _C OL__

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _U L

23 123 0.36 123 P 2 TWD 16 07H

+0.35 TEA TEC 5

COLD 600UL 29 123 0.28 114 P 2 TWD 12 07H

+0.63 TEA TEC 6

COLD 600UL 43 123 0.39 88 P 2 TWD 17 07H

-- 0.42 +TEH TEC 5

COLD 600UL 59 123 0.25 79 P 2 TWD 12 07H

-0.29 TEH TEC 5

COLD 600UL 20 __24_0.52__105__P__2_TWO__19__07__-0.21___________T_____H____TEC_________6_____COLD________________________

20 124 0.52 105 P 2 TWD 19 07H

-0.21 TEN TEC 6

COLD 600UL

Framatome ANP Inc.

10/14/04 11:58:35 Customer Name: SONGS Unit 3 Component: S/G 88 Page 25 of 28 MAI, MCI, MMI, MVI, SAI, SCI, SVI, 0-100% TWD QUERY: rpc icodes and_0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 32 124 0.59 126 P 2 TWD 23 VSM

-0.70 TEH TEC 5

COLD 600UL 78 124 0.49 114 P 2 TWD 19 VH3

+0.00 TEH TEC 6

COLD 600UL 0.68 80 P 2 TWD 24 VH3

+0.98 TEH TEC 6

COLD 600UL 0.43 75 P 2 TWD 16 VC3

-0.73 TEH TEC 6

COLD 600UL 0.66 95 P 2 TWD 23 VC3

+0.90 TEA TEC 6

COLD 600UL 120 124 0.46 107 P 2 TWD 19 10H

+1.50 TEH TEC LOCOR 15 COLD 600UL 125------0.50 20 p---1-----C----_T-__

-15.44-____ _____

=------0.18 18.51 118---HOT----------P 11 125 0.50 20 P 1 SCI TSH

-15.44 TSH TSH 0.18 18.51 118 HOT 580PP 0.28 20 P 1 SCI TSH

-13.80 TSH TSH 0.16 18.51 118 HOT 580PP 35 125 0.40 108 P 2 TWD 18 VSM

+0.80 TEH TEC 5

COLD 600UL 0.30 148 P 2 TWD 13 VSM

-0.76 TEH TEC 5

COLD 600UL 49 125 0.33 118 P 2 TWD 14 08H

-1.28 TEH TEC LOCOR 6

COLD 600UL 0.46 74 P 2 TWD 18 08H

+1.67 TEH TEC LOCOK 6

COLD 600UL 0.29 55 P 2 TWD 12 08C

-1.34 TEH TEC LOCOK 6

COLD 600UL 79__125__0.42_

106__

P_ 2__TWO_18_______

+0.84 TEH----------------TEC---------------

5---

COLD----------------------

79 125 0.42 106 P 2 TWD 18 VC3

+0.84 TEH TEC 5

COLD 600UL 0.35 123 P 2 TWD 15 VC3

-0.86 TEH TEC 5

COLD 600UL 24 126 0.38 108 P 2 TWD 15 07H

+0.74 TEH TEC 4

COLD 600UL 46 126 0.39 94 P 2 TWD 17 01H

+0.90 TEH TEC 5

COLD 600UL 48 126 0.55 143 P 2 TWD 21 VSM

+0.82 TEH TEC 6

COLD 600UL 114 126 0.43 145 P 2 TWD 17 VH2

-0.89 TEH TEC 46 COLD 600UL 0.33 101 P 2 TWD 14 VC2

-0.91 TEH TEC 46 COLD 600UL 11 127 0.54 29 P 1 SCI TSH

-0.04 TSH TSH 0.15 18.82 89 HOT 580PP 23 127 0.35 112 P 2 TWD 16 06H

+0.40 TEH TEC 3

COLD 600UL 37 127 0.37 77 P 2 TWD 14 VSM

-0.84 TEH TEC 4

COLD 600UL 49 127 0.41 65 P 2 TWD 16 08H

-1.22 TEH TEC 4

COLD 600UL 85 127 0.39 60 P 2 TWD 16 VH2

+0.80 TEH TEC 46 COLD 600UL 34 128 0.21 111 P 2 TWD il VSM

+0.76 TEH TEC 3

COLD 600UL 48 128 1.24 110 P 2 TWD 34 VSM

+0.02 TEH TEC 4

COLD 600UL 0.74 127 P 2 TWD 25 VSM

-0.63 TEH TEC 4

COLD 600UL 0.45 110 P 2 TWD 17 VSM

+0.73 TEH TEC 4

COLD 600UL 60 128 0.36 37 P 2 TWD 14 08H

+0.27 TEH TEC 4

COLD 600UL 64 128 0.32 118 P 2 TWD 13 08H

+0.38 TEH TEC 4

COLD 600UL 41 129 0.46 19 P 3 TWD 19 DBH

+1.70 TEH TEC 4

COLD 600UL 61 129 0.54 101 P 2 TWD 20 08H

+0.48 TEH TEC 4

COLD 600UL 81 129 0.83 113 P 2 TWD 29 VC3

+0.83 TEH TEC 45 COLD 600UL 0.35 63 P 2 TWD 15 VH3

+0.93 TEH TEC 45 COLD 600UL 129 129 0.38 138 P 3 TWD 16 DBH

+1.92 TEH TEC 46 COLD 600UL 82 130 0.34 110 P 2 TWD 17 VC3

-0.80 TEC TEH 9

HOT 600UL 0.65 142 P 2 TWD 26 VH3

-0.88 TEC TEH 9

HOT 600UL 128 130 0.27 90 P 2 TWD 14 08C

-0.98 TEC TEH 10 HOT 600UL 49 131 0.24 65 P 3 TWD 15 D8H

-1.02 TEC TEH 18 HOT 600UL 77 131 0.25 106 P 2 TWD 14 VH3

-0.90 TEC TEH 18 HOT 600UL 79 131 0.30 117 P 2 TWD 15 VSM

-0.55 TEC TEH 17 HOT 600UL 8

132 0.27 16 P 1 SCI TSH

-6.02 TSH TSH 0.14 19.54 60 HOT 580PP 76 132 0.30 148 P 2 TWD 16 VH3

+0.75 TEC TEH 18 HOT 600UL 80 132 0.10 136 P 3 TWD 5 DBC

+1.99 TEC TEH 17 HOT 600UL

Framatome ANP Inc.

10/14/04 11:58:35 Customer Name: SONGS Unit 3 Component: S/G 88 Page 26 of 28 MAI, MCI, MMI, MVI, SAI, SCI, SVI, 0-100% TWD QUERY: rpc icodes and 0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL I LEG.

PROBE 82 132 0.47 124 P 2 TWD 21 VH3

+0.81 TEC TEH 9

HOT 600UL 0.30 146 P 2 TWD 15 VH3

-0.91 TEC TEH 9

HOT 60OUL 112 132 0.42 40 P 2 TWD 20 VC3

+0.62 TEC TEH 10 HOT 600UL 0.31 81 P 2 TWD 16 VC2

-0.90 TEC TEH 10 HOT 600UL 114__132 _0.32__

130__P_2_TW___16 _____

0.84_________

_TEC________

TEE_________9_______OT___

114 132 0.32 130 P 2 TWD 16 VH2

-0.84 TEC TEH 9

HOT 600UL 113 133 0.33 109 P 2 TWD 17 VH2

-0.70 TEC TEH 9

HOT 600UL 115 133 0.41 71 P 2 TWD 20 VH1

+0.88 TEC TEH 10 HOT 600UL 8

134 0.24 57 P 3 TWD 15 DBC

-0.87 TEC TEH 46 HOT 600UL 94 134 0.42 56 P 2 TWD 20 VH2

-1.06 TEC TEH 9

HOT 600UL 0.15 28 P 3 TWD 8 DBC

+2.06 TEC TEH 9

HOT 600UL 100 134 0.18 114 P 3 TWD 11 DBC

+2.16 TEC TEH 10 HOT 600UL 706 134 0.67 128 P 2 TWD 27 VH2

-0.90 TEC TEH 9

HOT 600UL 110 134 0.38 139 P 2 TWD 19 VH2

-0.71 TEC TEH 9

HOT 600UL 124 134 0.10 56 P 3 TWD 6 DBH

+1.83 TEC TEH 10 HOT 600UL 76 136 0.32 128 P 2 TWD 17 VSM

-0.77 TEC TEH 18 HOT 600UL 0.50 101 P 2 TWD 23 VH3

+0.94 TEC TEH 21 HOT 600UL 70 138 0.41 107 P 2 TWD 19 VC3

-0.92 TEC TEH 21 HOT 600UL 114 138 0.37 84 P 2 TWD 18 VH2

-0.87 TEC TEH 10 HOT 600UL 11 139 0.29 18 P 1 SCI TS1

-14.57 TSH TSH 0.12 18.39 155 HOT 580PP 83 139 0.27 148 P 2 TWD 14 VH2

+0.79 TEC TEH 10 HOT 600UL 80____1

___2 __0. ____2__127_____P__2___TWO____25____VC3_______________TEC_____T______21 HOT.--------600 ---------

80 14D 0.48 139 P 2 TWD 21 VC3

+0.75 TEC TEH 21 HOT 600UL 0.84 112 P 2 TWD 30 VC3

-0.91 TEC TEH 21 HOT 600UL 0.34 152 P 2 TWD 16 VH3

+0.83 TEC TEH 21 HOT 600UL 0.46 111 P 2 TWD 21 VH3

-0.89 TEC TEH 21 HOT 600UL 110 140 0.29 103 P 2 TWD 15 VH2

+0.60 TEC TEH 9

HOT 600UL 61 141 0.30 135 P 2 TWD 16 VSM

-0.83 TEC TEH 22 HOT 600UL 81 141 0.32 145 P 2 TWD 17 VH3

+0.93 TEC TEH 13 HOT 600UL 0.38 156 P 2 TWD 19 VH3

-0.73 TEC TEH 13 HOT 600UL 60 142 0.28 57 P 2 TWD 15 VH3

-0.92 TEC TEH 22 HOT 600UL 80 142 0.62 127 P 2 TWD 25 VC3

+0.79 TEC TEH 21 HOT 600UL 0.48 147 P 2 TWD 21 VC3

-0.87 TEC TEH 21 HOT 600UL 0.24 99 P 2 TWD 12 VSM

+0.91 TEC TEH 21 HOT 600UL 0.44 144 P 2 TWD 20 VSM

-0.B1 TEC TEH 21 HOT 600UL 0.46 138 P 2 TWD 21 VH3

+0.77 TEC TEH 21 HOT 600UL 0.56 136 P 2 TWD 24 VH3

-0.89 TEC TEH 213 HOT 600UL 98 142 0.36 143 P 2 TWD 17 VH2

-0.99 TEC TEH 13 HOT 600UL 108 142 0.48 108 P 2 TWD 23 VH2

-0.83 TEC TEH 14 HOT 600UL 110 142 0.38.76 P 2 TWD 18 VC2

-1.03 TEC TEH 13 HOT 600UL 37 143 0.44 72 P 2 TWD 20 01H

+0.71 TEC TEH 21 HOT 600UL 57 143 0.42 98 P 2 TWD 19 05H

-0.24 TEC TEH 21 HOT 600UL 67 143 0.48 108 P 2 TWD 21 VH3

+0.89 TEC TEH 21 HOT 600UL 105 143 0.41 57 P 2 TWD 19 VH2

-0.89 TEC TEH 13 HOT 600UL -

107 143 0.41 130 P-2 TWD 20 VH2

-0.77 TEC TEH 14 HOT 600UL 94 144 0.29 116 P 2 TWD 15 VH2

-1.13 TEC TEH.

13 HOT 600UL

Framatome ANP Inc.

10/14/04 11:58:35 Customer Name: SONGS Unit 3 Component: S/G 88 Page 27 of 28 MAI, MCI, MMI, MVI, SAI, SCI, SVI, 0-100% TWD QUERY: rpc icodes and_0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 23 145 0.29 113 P 2 TWD 17 VSM

-1.04 TEC TEH 25 HOT 600UL 59 145 0.51 85 P 2 TWD 22 VH3

+0.95 TEC TEH 21 HOT 600UL 0.37 133 P 2 TWD 18 VH3

-0.85 TEC TEH 21 HOT 600UL 56 146 0.48 124 P 2 TWD 24 VH3

-0.83 TEC TEH 25 HOT 600UL 70____146_____0.22________5___P___2___TWO_____14____________+0.80_______T___d___T_______26____HOT______________

70 146 0.22 85 P 2 TWD 14 01H

+0.80 TEC TEH 26 HOT 600UL 94 146 0.28 85 P 2 TWD 15 VH2

-0.89 TEC TER 13 HOT 600UL 0.30 122 P 2 TWD 16 VH2

+0.95 TEC TEH 13 HOT 600UL 0.69 108 P 2 TWD 28 VH3

-0.91 TEC TEH 13 HOT 600UL 37______47____0.24______142_____p___2__TWO_____14____VSM_____+0.7________T__C___TE______26____HOT______________

37 147 0.24 142 P 2 TWD 14 VSM

+0.78 TEC TEH 26 HOT 600UL 72 148 0.24 135 P 2 TWD 14 VC3

+0.94 TEC TEH 26 HOT 600UL 94 148 0.32 65 P 2 TWD 16 VC3

+0.91 TEC TER 13 HOT 600UL 100 148 0.35 113 P 2 TWD 18 VH2

-0.87 TEC TEH 14 HOT 600UL 11 149 0.30 12 P 1 SCI TSH

-17.38 TSH TSH 0.19 18.49 146 HOT 580PP 0.93 27 P 1 SCI TEH

+0.96 TEH TEH 0.21 190 HOT 580PP 43 149 0.40 68 P 2 TWD 21 VSM

+0.90 TEC TEH 25 HOT 600UL 61 149 0.34 139 P 2 TWD 19 VH3

-0.90 TEC TEH 26 HOT 60OUL 93 149 0.22 31 P 3 TWD 15 DBC

-1.68 TEC TEH 14 HOT 600UL 60__150__0.35__149__P_2_TWO__19__V___-0.94___________T_____d_____TE_________26_______HO________________________

60 150 0.35 149 P 2 TWD 19 VH3

-0.94 TEC TEH 26 HOT 600UL 64 150 0.33 148 P 2 TWD 19 VH3

+0.77 TEC TEH 26 HOT 600UL 51 151 0.29 51 P 2 TWD 16 03H

-1.18 TEC TEH 25 HOT 600UL 82__152__0.38__112__P_2_TW___18____C_-0.20___________T_____d___________H____13_______HOT_______________________

89 151 0.24 113 P 2 TWD 13 VC3

-0.89 TEC TER 14 HOT 600UL 48 152 0.56 101 P 2 TWD 27 VSM

-0.65 TEC TER 26 HOT 600UL 82 152 0.38 112 P 2 TWD 18 08C

-0.20 TEC TER 13 HOT 600UL I

96 152 23 153 67 153 71 153 81 153 83 153 44 154 48 154 54 156 83 157 85 157 74 160 31 161 0.31 n - x 0.41 0.44 0.21 0.40 0.36 0.27 0.80 0.33 0.27 0.41 0.17 94 P 2 TWD 17 86 P 2 TWD 20 132 P 2 TWD 21 127 P 2 TWD 22 165 P 3 TWD 9 108 P 2 TWD 19 104 P 2 TWD 20 154 P 2 TWD 16 90 P 2 TWD 32 103 P 2 TWD 16 34 P 3 TWD 17 73 P 2 TWD 21 164 P 3 TWD 9 VH3 VH3 DBC VH2 VSM VSM VH3 VH2 DBH 08C DBH

-0.89

+0.00

+1.80

+0.85

+0.68

+0.77

+0.77

+0.73

+0.85

+2.25

-0.14

+1.44 02C

+0.79 TEC TER

_-q

__g rr r

TEC TEC TE_

TEC TEC TEC TEC TEC TEC TEC TEC TER TEH TEH TE_

TEH TER TEH TER TEH TEH TEH 14 HOT 25 HOT_____

25 HOT 25 HOT 25 HOT 13 HOT 13 HOT 26 HOT 26 HOT 29 HOT 13 HOT 14 HOT 29 HOT 29 HOT 600UL 600UL 60OUL 600UL 600UL 600UL

____________L__

600UL 60OUL 600UL 600UL 600UL 600UL 60OUL

~~~~---

60OUL B

l-----

0 P

-I.

77 161 0.22 35 P 2 TWD 13 07C

-0.96 TEC TEH 30 HOT 600UL 0.23 107 P 2 TWD 13 08C

-0.96 TEC TER 30 HOT 600UL 0.15 143 P 3 TWD 11 DBH

+1.67 TEC TEH 30 HOT 600UL 79 161 0.35 86 P 3 TWD 15 DBH

+1.74 TEC TEH 29 HOT 600UL 0.28 105 P 2 TWD 16 08H

+0.69 TEC TEH 29 HOT 600UL 36____162_____0.28______145_____P___2__TWO_____15____________40.86_______TEC____TE______30____HOT______________

36 162 0.28 145 P 2 TWD 15 VSM

+0.86 TEC TER 30 HOT 600UL

Framatome ANP Inc.

Customer Name: SONGS Unit 3 10/14/04 11:58:35 Component: S/G 88 Page 28 of 28 MAI, MCI, MMI, MVI, SAI, SCI, SVI, 0-100% TWD QUERY: rpc icodes and_0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 70 162 0.30 154 P 2 TWD 17 08H

+0.81 TEC TEH 29 HOT 600UL 65 163 0.31 129 P 2 TWD 17 VH3

-0.74 TEC TEH 30 HOT 600UL 70 164 0.41 46 P 2 TWD 21 08H

+0.99 TEC TEH 29 HOT 600UL 65 165 0.36 124 P 2 TWD 19 01C

-0.96 TEC TEN 30 HOT 600UL 56 166 0.64 76 P 2 TWD 24 01C

-0.90 TEH TEC 47 COLD 600UL 62 166 0.29 57 P 2 TWD 14 01H

+0.08 TEC TEN 35 HOT 600UL 31 167 0.26 128 P 3 TWD 16 DBH

+0.66 TEC TEH 40 HOT 600UL 57 167 0.33 128 P 2 TWD 15 01H

+0.10 TEC TEH 35 HOT 600UL 32 168 0.11 112 P 3 TWD 8 DBH

+0.00 TEC TEN 40 HOT 600UL 52 168 0.41 120 P 2 TWD 20 01C

-0.15 TEC TEN 39 HOT 600UL 0.34 101 P 2 TWD 18 01H

+0.06 TEC TEN 39 HOT 600UL 49 169 0.39 84 P 2 TWD 19 01C

-0.94 TEC TEN 39 HOT 600UL 38 170 0.20 68 P 2 TWD 11 01H

-0.10 TEC TEH 39 HOT 600UL 28 172 0.49 61 P 2 TWD 23 01C

-0.06 TEC TEH 40 HOT 600UL 30 172 0.32 38 P 2 TWD 17 06H

+0.88 TEC TEN 39 HOT 600UL 34 172 0.51 77 P 2 TWD 23 VSM

+0.87 TEC TEH 39 HOT 600UL 17 173 0.46 129 P 2 TWD 22 01C

-0.84 TEC TEN 40 HOT 600UL 14 174 0.84 108 P 2 TWD 31 01C

-0.10 TEC TEN 39 HOT 600UL 7

175 0.29 141 P 2 TWD 15 01C

-0.98 TEC TEN 50 HOT 600UL Total Tubes

853 Total Records: 1161

Inservice Inspection of Steam Generator Tubes Attachment Special Report Appendix 4 Inspection Summary Steam Generator E-089

Framatome ANP Inc.

Customer Name: SONGS Unit 3 10/14/04 07:17:53 Component: S/G 89 Page 1 of 20 Query Name : rpcicodesand_0-100%twd.qry i Query

Title:

MAI, MCI, MMI, MVI, SAI, SCI, SVI, 0-100% TWD Selected Outages/Scopess: 10/04 RFO13 10/04 RFO13 10/04 RFO13 10/04 RFO13 10/04 RFO13 10/04 RFO13 10/04 RFO13 10/04 RFO13 10/04 RFO13 10/04 RFO13 10/04 RFO13 10/04 RFO13 Out of Scope BOBBIN RPC TSH RPC TSC +1/-l RPC TSC +3/-l RPC UBENDS R1-3 RPC UBENDS R4-10 RPC 20% H/L SCALLOP BARS H/L SPECIAL INTEREST C/L SPECIAL INTEREST UBEND SPECIAL INTEREST Special Retest with RPC Input Selected

All Tubes Output File Selected :

Selected Indications : MAI,MCI,MMI,MVI,SAI,SCI,SVI,TWD, Selected Probes

ALL Selected Channels
ALL Selected Cals
ALL Selected Extentl
ALL Selected Extent2
ALL Selected Util 1 Selected Util 2 Selected Tube Heat TWD Range Volts Range Degrees Range Radius from Center Range Location Range Inspection Leg Queried : BOTH Include In-Service or Out-Service Tubes : In-Service only Advanced User Query

Framatome AUP Inc.

10/14/04 07:*17:53 Customer Name: SONGS Unit 3 Component: S/G 89 Page 2 of 20 MAI, MCI, MMI, MVI, SAI, SCI, SVI, 0-100% TWD QUERY: rpc icodes and 0-100%twd ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 27 3

0.37 115 2 SVI TSH

+10.63 TSH TSH 179 HOT 580PP 29 ____3 ___0. ____4 ___100 _____2___________T______+10.20________T

_______________216_____

HOT__

______P _______

29 3

0.14 100 2 SVI TSH

+10.20 TSH 01H 216 HOT 580PP 0.08 105 2 SVI TSH

+10.41 TSH 01H 216 HOT 580PP 0.08 96 2

SVI TSH

+10.61 TSH 01H 216 HOT 580PP 38 4

0.24 31 P 3 TWD 11 DBH

+1.32 TEC TEH 15 HOT 600UL 44_____6___0.38______142_____P___2___TW______16____________+0.74_______TEC_____TEH_____15______OT______________

44 6

0.38 142 P 2 TWD 16 VSM

+0.74 TEC TEH 15 HOT 600UL 41 7

0.30 114 P 2 TWD 17 VSM

-0.77 TEC TEH 16 HOT 600UL 0.42 89 P 2 TWD 20 VSM

+0.83 TEC TEH 16 HOT 600UL 18__8__0.27__110__P__2_TWO___12______-0.92___________T___________TE_________15_______HOT_______________________

18 8

0.27 110 P 2 TWD 12 02H

-0.92 TEC TEH 15 HOT 600UL 54 8

0.45 103 P 2 TWD 18 02C

-0.95 TEC TEH 15 HOT 600UL 55 9

0.29 114 P 2 TWD 13 02C

+0.12 TEC TEH 15 HOT 600UL 68 12 0.54 123 P 2 TWD 23 02C

+0.00 TEC TEH 20 HOT 600UL 72 14 0.39 149 P 2 TWD 16 VH3

-0.82 TEC TEH 19 HOT 600UL 48 16 0.27 19 P 2 TWD 14 03H

-1.09 TEC TEH 24 HOT 600UL 72 16 0.35 76 P 2 TWD 17 VH3

+0.71 TEC TEH 24 HOT 600UL 0.40 108 P 2 TWD 19 VH3

-1.24 TEC TEH 24 HOT 600UL 76 16 0.36 50 P 2 TWD 18 08C

+0.00 TEC TEH 24 HOT 600UL 78 16 0.41 73 P 2 TWD 16 05C

+0.80 TEC TEH 23 HOT 600UL 83 17 0.46.

103 P 2 TWD 24 08H

+0.73 TEC TEH 16 HOT 600UL 0.21 117 P 2 TWD 13 08H

+0.22 TEC TEH 16 HOT 600UL 0.39 62 P 2 TWD 21 02C

+0.86 TEC TEH 16 HOT 600UL 50 18 0.20 140 P 2 TWD 10 VSM

+0.69 TEC TEH 24 HOT 600UL 0.49 61 P 2 TWD 22 VSM

-0.84 TEC TEH 24 HOT 600UL 78 18 0.33 140 P 2 TWD 16 VH3

-0.88 TEC TEH 24 HOT 600UL 82 18 0.47 115 P 2 TWD 19 08C

+0.97 TEC TEH 15 HOT 600UL 75 19 0.70 133 P 2 TWD 28 VC3

+0.86 TEC TEH 24 HOT 600UL 0.27 57 P 2 TWD 14 VSM

-0.56 TEC TEH 24 HOT 600UL 50 20 0.47 114 P 2 TWD 21 VSM

+0.60 TEC TEH 24 HOT 600UL 0.60 77 P 2 TWD 25 VSM

+0.19 TEC TEH 24 HOT 600UL 24 22 0.26 134 P 2 TWD 14 VSM

-0.89 TEC TEH 20 HOT 600UL 68__22__0.44__148__P_2__TWO__18______-0.95___________T__________T_____________19______HOT______________________

68 22 0.44 148 P 2 TWD 18 VH3

-0.95 TEC TEH 19 HOT 600UL 72 22 0.34 117 P 2 TWD 15 VH3

-0.99 TEC TEH 19 HOT 600UL 63 23 0.33 89 P 2 TWD 16 01H

+0.76 TEC TEH 20 HOT 600UL 78 24 0.58 106 P 2 TWD 23 VC3

-0.91 TEC TEH 61 HOT 600UL 84 24 0.27 17 P 3 TWD 12 DBC

+1.33 TEC TEH 15 HOT 600UL 96 24 0.60 89 P 2 TWD 27 09C

+0.71 TEC TEH 16 HOT 600UL 98 24 0.45 152 P 2 TWD 18 04H

-1.00 TEC TEH 15 HOT 600UL 79 25 0.47 44 P 2 TWD 17 08C

-1.07 TEC TEH 23 HOT 600UL 99_ 25_

0.26_

126_P_2_ TW__ 11____

0.97-----

TEC T-----H----

15------HOT -------------------

99 25 0.26 126 P 2 TWD 11 VH2

-0.97 TEC TEH 15 HOT 600UL l0l 25 0.29 123 P 2 TWD 13 VH2

-0.93.

TEC TEH 15 HOT 600UL 65 27 0.79 57 P 2 TWD 24 VC3

-0.99 TEC TEH 29 HOT 600UL 1.12 136 P 2 TWD 30 VSM

-0.87 TEC TEH 29 HOT 600UL 0.34 99 P 2 TWD 13 VH3

+0.62 TEC TEH 29 HOT 600UL 81__27__0.22__63__P_3__TWO__13_______-1.58___________TEC________T_____________12______HOT______________________

81 27 0.22 63 P 3 TWD 13 DBH

-1.58 TEC TE H 12 HOT 600UL

Framatome ANP Inc.

10/14/04 07:17:53 Customer Name: SONGS Unit 3 Component: S/G 89 Page 3 of 20 MAI, MCI, MMI, MVI, SAI, SCI, SVI, 0-100% TWD QUERY: rpc icodes and 0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 97 27 0.12 134 P 3 TWD 8 DBC

-1.81 TEC TEH 12 HOT 600UL 38 28 0.39 62 P 2 TWD 18 VSM

+0.83 TEC TEH 30 HOT 600UL 0.30 80 P 2 TWD 15 VSM

-0.80 TEC TEH 30 HOT 600UL 66 28 0.30 107 P 2 TWD 15 VH3

-0.81 TEC TEH 30 HOT 600UL 106 28 0.36 142 P 3 TWD 15 DBH

+1.80 TEC TEH 11 HOT 600UL 0.36 137 P 2 TWD 15 VH2

-0.87 TEC TEH 11 HOT 600UL 77 29 0.78 122 P 2 TWD 24 VC3

+0.80 TEC TEH 29 HOT 600UL 79 29 0.50 65 P 2 TWD 18 VC3

+0.78 TEC TEH 29 HOT 600UL 0.31 117 P 2 TWD 12 VSM

-0.85 TEC TEH 29 HOT 600UL 81 29 0.44 139 P 2 TWD 21 VH3

+0.77 TEC TEH 12 HOT 600UL 36____30____0.____0___100_____P___2___TWD_____18____________+0.88_______TEC_____T___H___29____HOT______________

36 30 0.50 100 P 2 TWO 18 VSM

+0.88 TEC TEH 29 HOT 600UL 46 30 0.25 44 P 2 TWO 13 VSM

+0.14 TEC TEH 30 HOT 600UL 106 30 0.32 126 P 2 TWD 17 09H

+0.72 TEC TEH 12 HOT 600UL 85 31 0.21 32 P 3 TWD 13 DBH

-1.57 TEC TEH 12 HOT 600UL 97 31 0.32 121 P 2 TWD 16 VH2

-0.89 TEC TEH 12 HOT 600UL 105 31 0.29 156 P 2 TWD 15 VH2

-0.85 TEC TEH 12 HOT 600UL 107 31 0.37 112 P 3 TWD 15 DBH

-1.58 TEC TEH 11 HOT 600UL 84 32 0.16 18 P 3 TWD 10 DBH

-1.78 TEC TEH 12 HOT 600UL 110 32 0.17 163 P 3 TWD 8 DBH

+1.39 TEC TEH 11 HOT 60U 59 33 0.32 162 P 2 TWD 12 VH3

-0.97 TEC TEH 32 HOT 600UL 110 34 0.29 56 P 2 TWO 13 07H

+0.27 TEC TEH 11 HOT 600UL 46 36 1.07 107 P 2 TWD 34 VSM

-0.84 TEC TEH 33 HOT 60OUL 0.67 112 P 2 TWD 26 VSM

+0.92 TEC TEH 33 HOT 600UL 0.31 28 P 2 TWD 13 VSM

+0.27 TEC TEH 33 HOT 600UL 102 36 0.36 76 P 2 TWO 18 VH2

-0.78 TEC TEH 12 HOT 600UL 111 37 0.38 17 P 3 TWD 16 DBC

+2.17 TEC TEH 11 HOT 600UL 26 38 0.30 117 P 2 TWD 15 03H

-0.21.

TEC TEH 39 HOT 60OUL 38 38 0.48 104 P 2 TWD 20 VSM

+0.06 TEC TEH 33 HOT 600UL 112 38 0.32 16 P 3 TWD 18 DBH

+1.05 TEC TEH 12 HOT 600UL 41 39 0.17 47 P 3 TWD 8 DBC

+1.87 TEC TEH 38 HOT 600UL 69__39__0.38___87___2__TWO__16_______-0.89___________TEC________TEN________38______HOT_________________________

69 39 0.38 87 P 2 TWD 16 VH3

-0.89 TEC TEH 38 HOT 600UL 77 39 0.38 135 P 2 TWD 16 VC3

+0.85 TEC TEH 38 HOT 600UL 79 39 0.53 83 P 3 TWD 20 DBC

+1.77 TEC TEH 38 HOT 600UL 109 39 0.17 63 P 3 TWD 10 DBC

-1.35 TEC TEH 12 HOT 600UL 38 40 0.19 95 P 2 TWD 10 VSM

-0.11 TEC TEH 39 HOT 600UL 1.02 94 P 2 TWD 33 VSM

-0.73 TEC TEH 39 HOT 600UL 78 40 0.18 152 P 3 TWD 11 DBC

-1.75 TEC TEH 39 HOT 600UL 112 40 0.33 27 P 3 TWD 18 DBH

+1.47 TEC TEH 12 HOT 600UL 39 41 0.31 93 P 3 TWD 13 DBH

-1.90 TEC TEH 38 HOT 600UL 115 41 0.31 131 P 2 TWD 14 VH1

+0.84 TEC TEH 7

HOT 600UL 74 42 0.41 75 P 2 TWD 19 VH3

+0.77 TEC TEH 39 HOT 60OUL

Framatome ANP Inc.

Customer Name: SONGS Unit 3 MAI, MCI, MMI, MVI, SAI, SCI, SVI, 0-100% TWD QUERY: rpcqicodes and 0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION 10/14/04 07:17:53 Component: S/G 89 Page 4 of 20 EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE e---_--------

= -----

e------

88 42 0.27 84 P 2 TWD 12 VC3

+0.86 TEC TEH 7

HOT 600UL 100 42 0.33 48 P 2 TWD 15 VH2

-0.89 TEC TEH 7

HOT 600UL 110 42 0.32 83 P 2 TWD 16 VH2

-0.98 TEC TEH 8

HOT 600UL 23 43 0.37 119 P 2 TWD 18 01H

+0.86 TEC TEH 39 HOT 600UL 39____43____0.50______107_____P___2___TW______22____V___M___+0.91_______TEC_____TEH_____39____HOT______________

39 43 0.50 107 P 2 TWD 22 VSM

+0.91 TEC TEH 39 HOT 600UL 75 43 0.83 110 P 2 TWD 27 VC3

+0.74 TEC TEH 38 HOT 600UL 92 44 0.31 118 P 2 TWD 16 VH2

-0.86 TEC TEH 2

HOT 600UL 102 44 0.22 34 P 3 TWD 9 DBH

+1.88 TEC TEH 61 HOT 600UL 110 44 0.28 98 P 2 TWD 13 VH2

-0.65 TEC TEH 61 HOT 600UL 124 44 0.37 121 P 2 TWD 19 VH2

-0.82 TEC TEH 2

HOT 600UL 0.25 148 P 2 TWD 14 VH1

-0.90 TEC TEH 2

HOT 600UL 43 45 0.46 37 P 3 TWD 16 DBH

+1.68 TEC TEH 42 HOT 600UL 106 __46 __0_24__ 86_ P__

2_ TWO__14______

0.93____________TEC_________TEH ______

____2_____HOT______

75 45 0.30 158 P 2 TWD 11 VH3

-0.89 TEC TEH 42 HOT 600UL 107 45 0.66 95 P 2 TWD 25 VH2

-0.71 TEC TEH 61 HOT 600UL 0.82 39 P 2 TWD 28 VH2

+0.71 TEC TEH 61 HOT 600UL 115 45 0.80 136 P 2 TWD 28 VH1

-1.06 TEC TEH 61 HOT 600UL 88 46 0.36 123 P 3 TWD 14 DBC

-1.89 TEC TEH 61 HOT 60OUL 90 46 0.33 36 P 2 TWD 17 VH2

-1.18 TEC TEH 2

HOT 600UL 106 46 0.24 86 P 2 TWD 14 VH3

-0.93 TEC TEH 2

HOT 600UL 118 46 0.37 119 P 2 TWD 19 VH1

-0.99 TEC TEH 2

HOT 600UL 0.15 151 P 2 TWD 9 VH1

+0.86 TEC TEH 2

HOT 600UL 122 46 0.21 62 P 2 TWD 12 VH2

-0.81 TEC TEH 2

HOT 600UL 124 46 0.20 113 P 2 TWD 12 VH2

-0.91 TEC TEH 2

HOT 600UL 27 47 0.24 25 P 1 SCI TSH

-5.70 TSH TSH 0.19 139 HOT 580PP 0.26 28 P 1 SCI TSH

-0.10 TSH TSH 0.15 139 HOT 580PP 0.79 31 P 1 MCI TSH

-12.57 TSH TSH 0.66 19.10 139 -HOT 580PP 41 47 0.32 63 P 2 TWD 18 VSM

-0.08 TEH TEC 6

COLD 600UL 0.29 107 P 2 TWD 16 VSM

+0.80 TEH TEC 6

COLD 600UL 49 47 0.17 20 P 3 TWD 11 DBH

+1.00 TEH TEC 6

COLD 600UL 53 47 0.22 155 P 2 TWD 13 03C

+0.86 TEH TEC 6

COLD 600UL 57 47 0.37 118 P 2 TWD 20 08H

+0.52 TEH TEC 6

COLD 600VL 103 47 0.36 127 P 2 TWD 17 VH2

-0.90 TEH TEC 12 COLD 600UL 111 47 0.27 128 P 2 TWD 14 08C

+0.88 TEH TEC 12 COLD 600UL 26 48 0.49 26 P 2 TWD 21 VSM

-1.23 TEH TEC 5

COLD 600UL 60 48 0.58. 115 P 2 TWD 27 08H

-0.88 TEH TEC 6

COLD 600UL 88 48 0.38 120 P 2 TWD 18 VH2

-0.83 TEH TEC 11 COLD 600UL 49 49 0.55 130 P 2 TWD 26 08H

+1.61 TEH TEC LOCOK 6

COLD 600UL 65 49 0.49 153 P 2 TWD 24 VH3

-0.74 TEH TEC 6

COLD 600UL 0.19 -164 P 2 TWD 12 VH3

+0.78 TEH TEC 6

COLD 600UL 131 49 0.22 19 P 3 TWD 10 DBH

+1.60 TEC TEH.57 HOT 600UL 36 50 0.20 159 P 3 TWD 12 DBH

+2.23 TEH TEC 6

COLD 600UL

Framatome ANP Inc.

10/14/04 07:17:53 Customer Name: SONGS Unit 3 Component: S/G 89 Page 5 of 20 MAI, MCI, MMI, MVI, SAT, SCI, SVI, 0-100% TWD QUERY: rpcicodes and 0-100%twd.qry ROW LINE VOLTS DEG CHN INDA TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 60 50 0.38 133 P 2 TWD 20 08H

-0.41 TEH TEC 6

COLD 600UL 62 50 0.60 99 P 2 TWD 24 08H

-0.15 TEH TEC 5

COLD 600UL 102__50 __0.39__

96__

P2__

TWD__19____2_

0.81___

______T____

C_

=-----------COLD-----------------------------L-102 50 0.39 96 P 2 TWD 19 VH2

-0.81 TEH TEC 11 COLD 600UL 108 50 0.48 138 P 2 TWD 22 VH2

+0.99 TEH TEC 12 COLD 600UL 122 50 0.22 98 P 2 TWD 12 08C

+0.87 TEH TEC 11 COLD 600UL 31 51 0.29 103 P 2 TWD 14 06H

+0.81 TEH TEC 5

COLD 600UL 43 51 0.28 99 P 2 TWD 13 02H

+0.77 TEH TEC 5

COLD 600UL 57 51 0.19 99 P 2 TWD 12 08H

+0.36 TEH TEC 6

COLD 600UL 0.30 84 P 2 TWD 17 08H

+0.93 TEH TEC 6

COLD 600UL 81 51 0.19 155 P 3 TWD 10 D8H

+1.52 TEH TEC 11 COLD 600UL 127 51 0.34 34 P 3 TWD 16 DBH

-1.52 TEH TEC 11 COLD 600UL 82 52 0.12 10 P 3 TWD 6 DBC

+1.68 TEH TEC 11 COLD 600UL 102 52 0.14 62 P 3 TWD 8 DBC

+1.04 TEH TEC 11 COLD 600UL 37 53 0.45 144 P 2 TWD 23 VSM

+0.00 TEH TEC 6

COLD 60OUL 63 53 0.46 106 P 2 TWD 20 08H

+0.38 TEH TEC 5

COLD 600UL 65 53 0.31 101 P 2 TWO 18 08H

-0.64 TEH TEC 6

COLD 600UL 0.31 67 P 2 TWO 18 08H

-0.20 TEH TEC 6

COLD 600UL 71 53 0.30 19 P 2 TWD 14 08H

+0.52 TEH TEC 5

COLD 600UL 133 53 0.61 123 P 3 TWD 22 DBH

+1.91 TEC TEH 57 HOT 600UL 0.41 78 P 2 TWO 17 07H

+0.02 TEC 07H 57 HOT 60OUL 46 54 0.22 83 P 3 TWD 11 DBH

+1.84 TEH TEC 5

COLD 600UL 68 54 0.37 146 P 2 TWD 20 08H

+0.32 TEH TEC 6

COLD 600UL 76 54 0.18 154 P 3 TWD 11 DBH

+0.98 TEH TEC 6

COLD 600VL 130 54 0.21 28 P 3 TWID 11 DBH

+1.58 TEH TEC 11 COLD 600UL 132 54 0.25 40 P 3 TWD 11 DBH

+1.45 TEC TEH 57 HOT 600UL 33 55 0.33 42 P 2 TND 18 VSM

-0.85 TEH TEC 6

COLD 600UL 0.95 95 P 2 TWO 34 VSM

+0.85 TEH TEC 6

COLD 600UL 41 55 0.30 123 P 2 TWD 17 VSM-

-0.85 TEH TEC 6

COLD 600UL 67 55 0.29 127 P 2 TWD 14 08H

+0.63 TEH TEC 5

COLD 600UL 69 55 0.38 151 P 2 TWD 20 08H

+0.74 TEH TEC 6

COLD 600UL 107 55 0.42 37 P 2 TWD 19 08C

+0.94 TEH TEC 11 COLD 600UL 38 56 0.20 47 P 2 TWD 10 06H

+0.50 TEH TEC 5

COLD 600UL 70 56 0.26 125 P 2 TWD 13 08H

+0.65 TEH TEC 5

COLD 600UL 112 56 0.33 III P 2 TWO 17 VH2

-0.86 TEH TEC 12 COLD 600UL 0.27 143 P 2 TWO 13 VH2

+0.86 TEH TEC 12 COLD 600UL 126 56 0.28 136 P 2 TWO 14 VH1

+0.90 TEH TEC 11 COLD 600UL 125 57 0.69 121 P 2 TWD 28 VH1 08 TEH TEC 12 COLD 600UL 0.48 118 P 2 TWD 22 VH1

+0.80 TEH TEC 12 COLD 600UL 135 57 0.41 128 P 2 TWD 17 10H

+1.21 TEC TEH 57 HOT 600UL 22 58 0.36 106 P 2 TWD 17 03H

+0.84 TEH TEC 5

COLD 600UL 108 58 0.42 103 P 2 TWO 20 VC3

+0.87 TEH TEC 12 COLD 600UL

Framatome ANP Inc.

Customer Name: SONGS Unit 3 MAI, MCI, MMI, MVI, SAI, SCI, SVI, 0-100% TWD QUERY: rpc icodes andO-100%twd.qry 10/14/04 07:17:53 Component: S/G 89 Page 6 of 20 ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 124 58 0.20 34 P 3 TWD 11 DBH

-1.59 TEH TEC 12 COLD 600UL 0.42 120 P 2 TWD 20 VH1

-0.85 TEH TEC 12 COLD 600UL 0.37 64 P 2 TWD 18 VH1

+0.79 TEH TEC 12 COLD 600UL 0.37 97 P 2 TWD 18 VH2

-0.81 TEH TEC 12 COLD 600UL 134 58 0.48 91 P 2 TWD 19 VC3

+0.61 TEC TEH 57 HOT 600UL 136 58 0.26 23 P 3 TWD 11 DBH

-1.38 TEC TEH 57 HOT 600UL 41__59__0.53__100__p_2__TWO__25__V___-0.81___________TE__________T_____C____6_____COLD_______________________L_

91 59 0.53 100 P 2 TWD 25 VSM

-0.81 TEH TEC 6

COLD 600UL 0.58 101 P 2 TWO 27 VSM

+0.00 TEH TEC 6

COLD 600UL 65 59 0.69 125 P 2 TWD 29 VSM

-0.85 TEH TEC 6

COLD 600UL 0.27 159 P 2 TWD 16 VSM

+0.72 TEH TEC 6

COLD 600UL 83 59 0.42 32 P 3 TWD 20 DBH

+1.47 TEH TEC 12 COLD 600UL 137 59 0.14 19 P 3 TWD 6 DBC

+1.76 TEC TEH 57 HOT 600UL 66 60 0.50 55 P 2 TWD 21 01H

+1.02 TEH TEC 5

COLD 600UL 0.45 134 P 2 TWD 20 VSM

-0.82 TEH TEC 5

COLD 600UL 1.05 117 P 2 TWO 34 VSM

+0.75 TEH TEC 5

COLD 600UL 78 60 0.51 116 P 1 SVI DBH

+2.76 DBH DBH 175 HOT 560P2 84 60 0.21 53 P 3 TWD 11 DBH

+1.24 TEH TEC 10 COLD 600UL 132 60 0.71 36 P 2 TWD 25 VH2

-0.84 TEC TEH 57 HOT 600UL 0.59 42 P 2 TWD 22 VH1

-0.88 TEC TEH 57 HOT 600UL 27 61 0.35 22 P 1 SCI TSH

-10.06 TSH TSH 0.18 18.44 147 HOT 580PP 0.35 14 2

SAI TSH

-1.78 TSH TSH 0.14 18.44 147 HOT 580PP 0.36 15 2

SAI TSH

-1.27 TSH TSH 0.17 18.44 147 HOT 580PP 33 61 0.37 139 P 2 TWD 17 VSM

+0.76 TEH TEC 4

COLD 600UL 49 61 0.22 107 P 2 TWD 12 08C

+1.61 TEH TEC LOCOK 4

COLD 600UL 77 61 0.59 114 P 2 TWD 24 VH3

-0.83 TEH TEC 4

COLD 600UL 0.63 148 P 2 TWD 25 VSM

+0.73 TEH TEC 4

COLD 600UL 79__61__0.34___0_p__2_TWO__16________-0.78___________TEA_________TEC________3_____COLD_________________________

79 61 0.34 0

P 2 TWO 16 VH3

-0.78 TEH TEC 3

COLD 600UL 81 61 0.23 118 P 2 TWO 12 VH3

-0.76 TEH TEC 38 COLD 600UL 89 61 0.42 48 P 2 TWD 19 VH2

-0.68 TEH TEC 10 COLD 600UL 127 61 0.46 107 P 2 TWD 21 10H

+0.41 TEH TEC 38 COLD 600UL 129 61 0.24 87 P 2 TWD 12 VH1

-0.66 TEH TEC 10 COLD 600UL 42 62 0.34 71 P 2 TWD 16 VSM

+0.21 TEH TEC 3

COLD 600UL 50 62 0.43 0

P 2 TWO 19 08H

-1.24 TEH TEC 3

COLD 600UL 78 62 0.47 105 P 2 TWD 20 VC3

-0.71 TEH TEC 3

COLD 600UL 88 62 0.52 113 P 2 TWD 22 VH2

-0.74 TEH TEC 10 COLD 600UL 126 62 0.36 58 P 2 TWD 18 VH1

-0.92 TEH TEC 38 COLD 600UL 130 62 0.65 109 P 2 TWD 26 VH1

+0.90 TEH TEC 38 COLD 600UL 31 63 0.39 26 P 1 SCI TSH

-9.85 TSH TSH. 0.21 18.43 147 HOT 580PP 41 63 0.52 67 P 2 TWD 22 VSM

-0.83 TEH TEC 4

COLD 600UL 0.62 66 P 2 TWD 25 VSM

+0.04 TEH TEC 4

COLD 600UL 127 63 0.33 108 P 2 TWO 16 VH1

+1.05 TEH TEC 39 COLD 600UL 0.22 114 P 2 TWD 12 VH1

-0.72 TEH TEC 39 COLD 600UL 129 63 0.37 121 P 2 TWD 18 10H

-+0.42 TEH TEC 10 COLD 600UL-0.50 74 P 2 TWD 22 VH1

+0.91 TEH TEC 10 COLD 600UL 80 64 0.22 0

P 3 TWD 10 DBH

+1.02 TEH TEC 3

COLD 600UL

Framatome ANP Inc.

10/14/04 07:17:53 Customer Name: SONGS Unit 3 Component: S/G 89 Page 7 of 20 MAI, MCI, MMI, MVI, SAI, SCI, SVI, 0-100% TWD QUERY: rpc icodes and_0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 82 64 0.49 87 P 2 TWD 22 VH3

+0.82 TEH TEC 38 COLD 600UL 88__64__

0.41_____

P2__ T__ D_ 19______

0.70___TE___TEC_--

___COL___- ________________________________________

88 64 0.41 63 P 2 TWD 19 VH2

-0.70 TEH TEC 10 COLD 600UL 96 64 0.52 35 P 2 TWD 22 VH2

-0.62 TEH TEC 10 COLD 600VL 140 64 0.68 71 P 3 TWO 24 DBH

-1.91 TEC TEH 57 HOT 600UL 25 65 0.32 131 P 2 TWO 15 VSM

+0.96 TEH TEC 3

COLD 600UL 36501172ST 4.15------TSH-----T-------0.14------18.40-------146-------OT------------

31 65 0.18 17 2

SAI TSH

-4.15 TSH TSH 0.14 18.40 146 HOT 580PP 0.38 20 2

SAI TSH

-3.81 TSH TSH 0.14 18.40 146 HOT 580PP 0.41 19 2

SAI TSH

-3.71 TSH TSH 0.14 18.40 146 HOT 580PP 43 65 0.25 48 P 2 TWD 12 VSM

+0.19 TEH TEC 3

COLD 600UL 69 65 0.55 111 P 2 TWD 23 VC3

-0.72 TEH TEC 4

COLD 600UL 0.38 72 P 2 TWD 18 VC3

+0.10 TEH TEC 4

COLD 600UL 71_____65____0.28______150_____P2____TWD_____14____________+0.78_______TEH_____TEC_____3___COLD________________

71 65 0.28 150 P 2 TWD 14 VH3

+0.78 TEH TEC 3

COLD 600UL 125 65 0.29 147 P 2 TWD 15 VH1

+0.68 TEH TEC 10 COLD 600UL 127 65 0.29 144 P 2 TWD 15 VH1

+0.64 TEH TEC 39 COLD 600UL 133 65 0.19 53 P 3 TWD 9 DBH

+1.89 TEC TEH 59 HOT 600UL 40 66 0.19 0

P 3 TWD 9 DBC

+1.24 TEH TEC 3

COLD 600UL 44 66 0.12 0

P 3 TWO 6 DBC

+1.15 TEH TEC 3

COLD 600UL 50 66 0.51 47 P 2 TWD 22 08H

+1.25 TEH TEC 4

COLD 600UL 86 66 0.43 121 P 2 TWD 20 09H

+0.21 TEH TEC 38 COLD 600UL 88 66 0.28 76 P 2 TWD 14 09H

+0.89 TEH TEC 10 COLD 600UL 124 66 0.41 149 P 2 TWD 19 VH1

-0.66 TEH TE C 10 COLD 600UL 130 66 0.36 133 P 2 TWD 17 VHI

+0.86 TEH TEC 39 COLD 600UL 0.23 70 P 2 TWO 12 08C

+0.87 TEH TEC 39 COLD 600UL 21 67 0.50 77 P 2 TWO 21 VSM

-1.03 TEH TEC 3

COLD 600UL 25 67 0.29 98 P 2 TWO 14 VSM

-0.94 TEH TEC 3

COLD 600UL 31 67 0.54 15 2

SAI TSH

-4.53 TSH TSH 0.28 18.52 146 HOT 580PP 91 67 0.33 143 P 2 TWD 16 VH3

-0.86 TEH TEC 38 COLD 600UL 99 67 0.19 154 P 3 TWD 9 DBH

+1.92

.TEH TEC 38 COLD 600UL 111 67 0.70 26 P 1 SCI TSH

-22.67 TSH TSH

.23 22.75 117 HOT 58OPP 127 67 0.33 124 P 2 TWD 16 VH1

+0.04 TEH TEC 39 COLD 600UL 141 67 0.35 154 P 2 TWD 16 VH1

-0.77 TEC TEH 59 HOT 600UL 0.23 71 P 3 TWD 11 DBC

-1.77 TEC TEH 59 HOT 600UL 24 68 0.34 120 P 3 TWD 14 DBH

+1.70 TEH TEC 41 COLD 600UL 40 68 0.44

.25 P 2 TWD 18 VSM

-0.86 TEH TEC 3

COLD 600UL 130 68 0.53 138 P 2 TWD 23 VH1

+1.03 TEH TEC 39 COLD 600UL 0.18 132 P 3 TWD 9 DBH

+0.00 TEH TEC 39 COLD 600UL 134 68 0.55 144 P 2 TWD 22 10H

-0.79 TEC TEH 59 HOT 600UL 0.26 100 P 2 TWO 13 10H

+0.79 TEC TEH 59 HOT 600UL 39____69____0.47______145_____P___2___TWO_____21____________+0.79_________E_____TEC_____4___COLD_______________

39 69 0.47 145 P 2 TWD 21 VSM

+0.79 TEH TEC 4

COLD 600UL 41 69 0.46 99 P 2 TWD 20 VSM

+0.84 TEH TEC 3

COLD 600UL 144 70 0.65 94 P 2 TWD 25 VC1

+0.34 TEC TEH 59 HOT 600UL 33 71 0.77 118 P 3 TWD 28 DBC

+1.55 TEH TEC 4

COLD 600UL

Framatome ANP Inc.

10/14/04 07:17:53 Customer Name: SONGS Unit 3 Component: S/G 89 Page 8 of 20 MAI, MCI, MMI, MVI, SAI, SCI, SVI, 0-100% TWD QUERY: rpcicodes and 0-100%twd.qry ROW LINE VOLTS DEG CAN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

= --

_= _- -

35 71 0.92 108 P 2 TWD 31 VSM

-0.85 TEN TEC 3

COLD 600UL 0.19 125 P 2 TWD 7 VSM

-0.08 TEN TEC 3

COLD 600UL 0.26 0

P 3 TWD 12 DBC

+1.51 TEH TEC 3

COLD 600UL 89 71 0.27 136 P 2 TWD 14 09H

+0.41 TEH TEC 38 COLD 600UL 97 71 0.15 111 P 3 TWD 7 DBH

+1.86 TEH TEC 38 COLD 600UL 36 72 0.36 64 P 3 TWD 16 DBH

-1.10 TEN TEC 3

COLD 600UL 44 72 0.60 145 P 3 TWD 24 DBC

+1.49 TEN TEC 4

COLD 600UL 46 72 0.36 86 P 2 TWD 17 VSM

+0.82 TEH TEC 3

COLD 600UL 130 72 0.54 138 P 2 TWD 23 VH1

+0.76 TEN TEC 39 COLD 600UL 132 72 0.49 142 P 2 TWD 20 VH1

+0.92 TEC TEH 59 HOT 600UL 0.54 42 P 2 TWD 22 10H

+0.88 TEC TEH 59 HOT 600UL 39 73 0.69 52 P 3 TWD 27 DBH

+1.62 TEN TEC 4

COLD 600UL 47 73 0.73 67 P 3 TWD 27 DBH

+2.12 TEN TEC 3

COLD 600UL 83____73____0.23______174_____P___3___T___O___16____________+1.74_______TEN_____TEC_____8___COLD______________L 83 73 0.23 174 P 3 TWD 16 DBH

+1.74 TEN TEC 8

COLD 600UL 89 73 0.09 134 P 3 TWD 4 DBH

-0.71 TEH TEC 7

COLD 600UL 145 73 0.37 102 P 3 TWD 15 DBH

+1.17 TEC TEC 59 HOT 600UL 44 74 0.31 77 P 3 TWD 15 DBH

-1.36 TEN TEC 4

COLD 600UL 50 74 0.15 0

P 3 TWD 7 DBH

-1.05 TEN TEC 3

COLD 600UL 80 74 0.11 0

P 3 TWD 5 DBH

+0.58 TEH TEC 3

COLD 600UL 122 74 0.33 98 P 2 TWD 18 VH2

-0.92 TEC TEC 8

COLD 600UL 134__74__0.63__150__P_2_TWO__24__VH__-0.84___________TEC________TEN________59______HOT_________________________

132 74 0.31 146 P 2 TWD 14 VH2

-0.82 TEC TEH 59 HOT 600UL 134 74 0.63 150 P 2 TWD 24 VH2

-0.84 TEC TEH 59 HOT 600UL 136 74 0.45 123 P 2 TWD 19 VH1

+0.88 TEC TEN 59 HOT 600UL 71 75 0.26 62 P 2 TWD 13 VH3

+0.87 TEH TEC 3

COLD 600UL 77 75 0.42 47 P 2 TWD 19 VH3

-0.99 TEH TEC 4

COLD 600UL 0.25 129 P 3 TWD 23 DBC

+1.90 TEC TEC 4

COLD 600UL 12 76 0.36 156 P 3 TWD 17 DBC

-1.84 TEC TEN 25 HOT 600UL 56 76 0.45 105 P 2 TWD 21 VSM

+0.64 TEC TEN 26 HOT 600UL 86 76 0.24 99 P 2 TWD 14 07H

+0.20 TEC TEC 26 COLD 600UL 128 76 0.41 143 P 2 TWD 18 VH1

+0.72 TEC TEC 27 COLD 600UL 138 76 0.50 146 P 2 TWD 20 10H

+0.67 TEC TEN 59 HOT 600UL 122__78__0.39_129__P_2__TWO_18__Viii_-0.82___________TEN________TEC________27______COLD________________________

144 76 0.24 110 P 3 TWD 11 DBH

-1.95 TEC TEH 59 HOT 600UL 49 77 1.22 140 P 3 TWD 34 DBH

-1.88 TEC TEH 25 HOT 600UL 0.52 112 P 3 TWD 22 DBH

+1.76 TEC TEH 25 HOT 600UL 135 77 0.47 90 P 2 TWO 20 VH1

+0.94 TEC TEH 59 HOT 600UL 50 78 0.40 104 P 3 TWD 19 DBH

-1.72 TEC TEH 25 HOT 600UL 52 78 0.40 84 P 3 TWD 24 DBH

+1.38 TEC TEH 26 HOT 600UL 54 78 0.41 66 P 3 TWD 19 DBH

-1.82 TEC TEH 25 HOT 600UL 62 78 0.44 97 P 3 TWD 20 DBH

.+1.84 TEC TEH 25 HOT.

600UL 122 78 0.39 129 P 2 TWD 18 VH1

-0.82 TEH TEC 27 COLD 600UL

Framatome ANP Inc.

10/14/04 07:17:53 Customer Name: SONGS Unit 3 Component: S/G 89 Page 9 of 20 MAI, MCI, MMI, MVI, SAI, SCI, SVI, 0-100% TWD QUERY: rpcicodes and_0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 124 78 0.41 149 P 2 TWD 21 VH1

-0.97 TEH TEC 26 COLD 600UL 130 78 0.56 123 P 2 TWD 24 VH1

+0.83 TEH TEC 27 COLD 600UL 144 78 0.48 104 P 3 TWD 19 DBH

-2.12 TEC TEH 59 HOT 600UL 57 79 0.38 59 P 3 TWD 24 D8H

+1.24 TEC TEH 26 HOT 600UL 61 79 0.32 79 P 3 TWD 21 DBH

+1.99 TEC TEH 26 HOT 60OUL 75 79 0.87 141 P 2 TWD 26 VSM

+0.81 TEC TEH 25 HOT 600UL 0.30 148 P 2 TWD 12 VSM

-0.97 TEC TEH 25 HOT 600UL 127_____79____0.66_____________P__2___TW______26___________+0_________TEH_____TEC____27____COLD_____600________

127 79 0.66 Ill P 2 TWD 26 VH1

+0.'71 TEH TEC 27 COLD 600UL 129 79 131 79_

131 79 137 79 145 79 52 80 0.34 0.32 0.40 0.25 0.53 0.30 0.59 0.32_-

0.32 0.32 0.20 127 P 2 TWD 17 106 P 2 TWD 14 81 P 2 TWD 18 106 P 3 TWD 11 111 P 3 TWD 23 137 P 3 TWD 15 140 P 3 TWD 31 55 P 2 TWD 12 44 P 2 TWD 16 41______________

41 P 3 TWD 10 a

VH1 VH1 09H DBH DBH DBC DBH VH3 09H DBH

+0.77

+0.71

-0.82

-1.77

-2.19

-1.60

-1.85

-0.89

+0.33 F1.89 TEH TEC TE TE_

TEC TEH TEC___T__

TEC TEH T__C__TEH TEC TEH TEC TEH TEC TEH TE____TEC TEC TEH TEC TEH TEH TEC TEH TEC 26

____9__

59 59 59 25 25 27_____

26 25 25 27 COLD HOT HOT HOT HOT HOT HOT HOT COLD COLD 600UL 600UL 600UL 600UL 600____________

600UL 600UL 600UL 60 OUL 600UL 60 OUL b

- u 56 70 86 120 80 80 80 80 v

128 80 0.90 108 P 2 TWD 31 VH1

-0.76 TEH TEC 27 COLD 600UL 0.51 81 P 2 TWD 22 VH1

+0.82 TEH TEC 27 COLD 600UL 134 80 0.30 139 P 2 TWD 14 VH1

+0.67 TEC TEH 59 HOT 600UL 0.53 145 P 2 TWD 22 VH1

-0.88 TEC TEH 59 HOT 600UL 144 80 0.24 173 P 3 TWD 11 DBH.

+1.79 TEC TEH 59 HOT 600UL 53 81 0.71 73 P 3 TWD 27 DBC

-1.44 TEC TEH 25 HOT 600UL 59 81 0.70 62 P 3 TWD 34 DBH

+1.58 TEC TEH 26 HOT 600UL 63 81 0.49 131 P 3 TWD 28 DBH

+1.42 TEC TEH 26 HOT 600UL 137 81 0.38 33 P 2 TWD 16 08H

+0.84 TEC TEH 59 HOT 600UL 56 82 0.94 113 P 3 TWD 31 DBH

-1.85 TEC TEH 25 HOT 600UL 64 82 0.42 135 P 3 TWD 25 DBH

-1.50 TEC TEH 26 HOT 600UL 66 82 0.33 114 P 2 TWO 13 VH3

+0.91 TEC TEH 25 HOT 600UL 0.39 123 P 3 TWD 18 DBH

-1.50 TEC TEH 25 HOT 600UL 108 82 0.22 142 P 2 TWD 9 03C

-1.09 TEH TEC 24 COLD 600UL 132 82 0.61 103 P 2 TWD 24 VH1

+0.00 TEC TEH 59 HOT 600UL 142 82 0.61 20 P 3 TWD 23 DBC

+1.90 TEC TEH 59 HOT 600UL 57 83 0.48 36 P 3 TWD 21 DBH

-1.95 TEC TEH 25 HOT 600UL 0.32 166 P 3 TWD 16 DBH

+1.62 TEC TEH 25 HOT 600UL 63 83 0.94 94 P 3 TWD 38 DBC

+1.52 TEC TEH 26 HOT 600UL 101 83 0.41 19 P 1 SCI TSH

-0.09 TSH TSH

.20 20.73 77 HOT 58OPP 137 83 0.57 32 P 2 TWD 24 09H

+0.93 TEC TEH 31 HOT 600UL 72 84 0.29 154 P 2 TWD 16 VC3

-0.04 TEC TEH 26 HOT 600UL 0.42 134 P 2 TWD 21 VSM

-0.66 TEC TEH 26 HOT 600UL 0.44 122 P 2 TWD 22 VC3

+0.64 TEC TEH 26 HOT 600UL

Framatome ANP Inc.

10/14/04 07:17:53 Customer Name: SONGS Unit 3 Component: S/G 89 Page 10 of 20 MAI, MCI, MMI, MVI, SAI, SCI, SVI, 0-100% TWD QUERY: rpc icodes and 0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 126 84 0.29 150 P 2 TWD 14 VH1

+0.92 TEH TEC 23 COLD 600UL 134 84 0.36 138 P 2 TWD 17 VH1

-0.95 TEC TEH 31 HOT 600UL 144 84 0.61 55 P 2 TWD 24 VH3

+0.75 TEC TEH 61 HOT 600UL 55 85 0.68 158 P 3 TWD 26 DBH

+1.68 TEC TEH 25 HOT 600UL 61 85 1.16 93 P 3 TWD 34 DBC

-1.93 TEC TEH 25 HOT 600UL 63 85 0.33 160 P 3 TWD 21 DBH

+1.31 TEC TEH 26 HOT 600UL 127 85 0.71 98 P 2 TWD 27 VH1

-0.85 TEH TEC 23 COLD 600UL 139 85 0.27 70 P 2 TWD 14 VH3

+0.94 TEC TEH 31 HOT 600UL 58 86 0.87 126 P 3 TWD 30 DBH

-2.03 TEC TEH 25 HOT 600UL 70 86 0.29 128 P 3 TWD 15 DBC

+1.56 TEC TEH 25 HOT 600UL 122 86 0.15 148 P 3 TWD 7 DBH

+0.48 TEH TEC 23 COLD 600UL 126 86 0.34 102 P 2 TWD 16 VH1

-1.00 TEH TEC 23 COLD 600UL 0.32 66 P 2 TWD 15 VH1

+0.97 TEH TEC 23 COLD 600UL 132 86 0.75 40 P 2 TWD 29 VH2

-0.82 TEC TEH 35 HOT 600UL 0.34 77 P 2 TWD 17 VH1

-0.83 TEC TEH 35 HOT 600UL 134 86 0.25 63 P 2 TWD 13 10H

+0.24 TEC TEH 31 HOT 600UL 55 87 0.38 14 P 3 TWD 23 DBH

+1.65 TEC TEH 22 HOT 600UL 57 87 0.43 63 P 3 TWD 13 DBC

-1.75 TEC TEH 21 HOT 600UL 65____87

____0.59

______155_____P___3___TW______17____________+1.7________T_______TEH_____21____HOT______________

65 87 0.59 155 P 3 TWD 17 DBH

+1.71 TEC TEH 21 HOT 600UL 67 87 0.19 69 P 3 TWD 14 DBC

-1.91 TEC TEH 22 HOT 600UL 0.24 169 P 3 TWD 17 DBH

+1.60 TEC TEH 22 HOT 600UL 93 87 0.31 28 P 2 TWD 15 07H

+0.88 TEH TEC 23 COLD 600UL 0.40 145 P 2 TWD 18 08H

+0.77 TEH TEC 23 COLD 600UL 143 87 0.28 96 P 2 TWD 14 VH2

-0.79 TEC TEH 35 HOT 600UL 60 88 0.82 73 P 3 TWD 21 DBH

-1.28 TEC TEH 21 HOT 600UL 62 88 0.74 121 P 3 TWD 34 DBH

-1.97 TEC TEH 22 HOT 600UL 68-88 0.39 112 P 3 TWD 11 DBH

-1.51 TEC TEH 21 HOT 600UL 132 88 0.42 126 P 2 TWD 20 VH2

-0.85 TEC TEH 35 HOT 600UL 0.47 57 P 2 TWD 22 VH1

+0.86 TEC TEH 35 HOT 600UL 0.44 63 P 2 TWD 21 VH1

-0.81 TEC TEH 35 HOT 600UL 146 88 0.27 89 P 2 TWD 18 VH2

-1.10 TEC TEH 34 HOT 600UL 55 89 0.57 125 P 3 TWD 30 DBH

-1.99 TEC TEH 22 HOT 600UL 57 89 0.20 149 P 3 TWD 6 DBH

-2.24 TEC TEH 21 HOT 600UL 97 89 0.27 154 P 3 TWD 12 DBH

+0.00 TEH TEC 22 COLD 600UL 135 89 0.39 68 P 2 TWD 18 VH3

-0.93 TEC TEH 31 HOT 600UL 139_____89____0.27______104_____P___2__T___O___13____________+0.89_______TEC____TEH_____31____HOT______________

139 89 0.27 104 P 2 TWD 13 09H

+0.89 TEC TEH 31 HOT 600UL 0.11 130 P 2 TWD 6 09H

-0.89 TEC TEH 31 HOT 600UL 58 90 0.42 88 P 3 TWD 25 DBC

+1.56 TEC TEH 22 HOT 600UL 0.16 146 P 3 TWD 11 DBH

-1.61 TEC TEH 22 HOT 600UL 100 90 0.24 55 P 3 TWD 11 DBH

-1.75 TEH TEC 21 COLD 600UL 114 90 0.34 79 P 3 TWD 14 DBH

+1.75 TEH TEC 22 COLD 600UL 136 90 0.25 58 P 2 TWD 20 VH1

+0.70 TEC TEH 28 HOT 600UL

Framatome ANP Inc.

Customer Name: SONGS Unit 3 10/14/04 07:17:53 Component: S/G 89 Page 11 of 20 MAI, MCI, MMI, MVI, SAI, SCI, SVI, 0-100% TWD QUERY:

rpc icodes and 0-100ltwd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL 6 LEG PROBE

= -

146 90 0.30 110 P 2 TWD 15 VH3

-0.85 TEC TER 31 HOT 600UL 0.33 66 P 3 TWD 13 DBC

+2.01 TEC TEH 31 HOT 600UL 53 91 0.44 152 P 3 TWD 13 DBH

-2.02 TEC TEH 21 HOT 600UL 0.49 165 P 3 TWO 14 DBH

+1.94 TEC TEH 21 HOT 600UL 61 91 0.23 91 P 2 TWO 19 03H

+0.06 TEC TEE LAR 22 HOT 600UL 65 91 0.57 21 P 3 TWD 30 DBH

+1.99 TEC TEH 22 HOT 600UL 137 91 0.31 134 P 2 TWD 24 VH1

+0.80 TEC TEH 28 HOT 600UL 0.39 96 P 2 TWD 28 09H

+0.80 TEC TEE 28 HOT 600UL 145 91 0.50 144 P 3 TWD 26 DBH

-1.36 TEC TEH 28 HOT 600UL 60__92__

0.69__

139__ P_3__TWD __19 __DEE _ -

1.57___

T C------ H---

_____21___________HOT__________

=--------------

60 92 0.69 139 P 3 TWD 19 DBH

-1.57 TEC TEH 21 HOT 600UL 68 92 0.34 138 P 3 TWD 10 DBH 0TEC TER 21 HOT 600UL 70 92 0.15 40 P 3 TWO 11 DBH

-1.75 TEC TEH 22 HOT 600UL 100 92 0.45 52 P 2 TWD 18 02H

-1.24 TER TEC 22 COLD 600UL 118 92 0.23 73 P 2 TWD 12 VH1

+0.85 TEH TEC 21 COLD 600UL 120 92 0.42 56 P 2 TWD 18 VH1

+0.81 TEH TEC 22 COLD 600UL 130 92 0.73 89 P 2 TWD 27 VH1

-0.81 TEH TEC 21 COLD 600UL 146 92 0.52 55 P 3 TWD 19 DBH

+1.82 TEC TEE 31 HOT 600UL 51 93 0.60 19 P 3 TWD 31 DBH

+1.75 TEC TEE 22 HOT 600UL 53 93 0.48 138 P 3 TWD 14 DBH

-1.70 TEC TEH 21 HOT 600UL 55 93 0.19 103 P 3 TWD 13 DBH

+1.72 TEC TEE 22 HOT 600UL 63 93 0.21 103 P 2 TWO 18 08H

-1.09 TEC TEH 22 HOT 600UL 133 93 0.13 127 P 2 TWD 11 VH1

-0.94 TEC TEH 28 HOT 600UL 52 94 0.30 64 P 3 TWD 9 DBC

-1.16 TEC TEH 21 HOT 600UL 0.42 25 P 3 TWD 13 DBH

+1.80 TEC TEH 21 HOT 600UL 60 94 0.16 76 P 3 TWD 4 DBH

-2.02 TEC TEE 21 HOT 600UL 0.22 7

P 3 TWD 6 DBH

+1.47 TEC TEE 21 HOT 600UL 78 94 0.35 75 P 3 TWD 22 DBH

+1.81 TEC TEH 22 HOT 600UL 82 94 0.35 142 P 2 TWD 17 VH3

-0.04 TEE TEC 21 COLD 600UL 130 94 0.47 126 P 2 TWO 21 VH2

-0.95 TEE TEC 21 COLD 600UL 0.65 115 P 2 TWD 23 VH1

+0.70 TEE TEC 21 COLD 600UL 136 94 0.40 106 P 2 TWD 18 VH1

-0.95 TEC TEE 31 HOT 600UL 144 94 0.24 71 P 3 TWD 10 DBH

+1.77 TEC TER 31 HOT 600UL 146 94 0.46 26 P 3 TWD 29 DBC

+1.48 TEC TEH 28 HOT 600UL 53 95 0.37 115 P 3 TWD 23 DBC

-1.70 TEC TEE 22 HOT 600UL 0.25 49 P 3 TWD 17. DBH

+2.00 TEC TEH 22 HOT 600UL 55 95 0.32 99 P 3 TWD 12 DBH

-1.86 TEC TEE 21 HOT 600UL 61 95 0.68 22 P 3 TWD 33 DEC

+2.06 TEC TEE 22 HOT 600UL 75 95 0.71 66 P 2 TWD 23 VC3

-0.90 TEC TEE 21 HOT 600UL 133 95 0.31 118 P 2 TWD 15 VH1

+0.91.

TEC TEE 31 HOT 600UL 135__95__0.16__62_P__2_TWO__15_______-1.02___________T_____C_____TE_________28_______HOT_______________________

135 95 0.16 62 P 2 TWD 14 VH1

-1.02 TEC TEE 28 HOT 600UL 143__95__0.19__25__P_3__TWO__13__DEE_-1.60___________TEC_________TEE________28_______HOT_______________________

139 95 0.16 56 P 2 TWO 14 VH1

-1.03 TEC TER 28 HOT 600UL 143 95 0.19 25 P 3 TWD 13 D8H

-1.60 TEC TER 28 HOT 600UL

Framatome ANP Inc.

10/14/04 07:17:53 Customer Name: SONGS Unit 3 Component: S/G 89 Page 12 of 20 MAI, MCI, MMI, MVI, SAI, SCI, SVI, 0-100% TWD QUERY: rpc icodesand 0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 56 96 0.91 141 P 3 TWD 23 DBC

+1.87 TEC TEH 21 HOT 600UL 0.22 72 P 3 TWD 7 DBH

-1.85 TEC TEH 21 HOT 600UL 64 96 0.39 72 P 3 TWD 12 DBC

+1.83 TEC TEH 21 HOT 600UL 49 97 0.23 62 P 3 TWD 16 DBH

+1.75 TEC TEH 22 HOT 600UL 53 __97__ 0.30__

42__ P_3___

W___19__DE__

- 1.76___

_____T___C____

TEH___

22----------HOT-------------------------------

53 97 0.30 42 P 3 TWD 19 DBH

-1.76 TEC TEH 22 HOT 600UL 59 97 0.16 145 P 3 TWD 7 DBC

-1.46 TEC TEH 21 HOT 600UL 61 97 0.24 96 P 3 TWD 7 DBC

-1.85 TEC TEH 21 HOT 600UL 105 97 0.18 89 P 3 TWD 8 DBH

-1.80 TEH TEC 22 COLD 600UL 141 97 0.14 64 P 3 TWD 10 DBC

-1.75 TEC TEH 28 HOT 600UL 145 97 0.16 119 P 3 TWD 13 DBC

-i.42 TEC TEH 28 HOT 600UL 50 98 0.23 57 P 3 TWD 16 DBC

-1.74 TEC TEH 22 HOT 600UL 0.38 76 P 3 TWD 23 DBH

-1.90 TEC TEH 22 HOT 600UL 124 98 0.26 102 P 2 TWD 13 VH1

+0.95 TEH TEC 21 COLD 600UL S1 99 0.40 158 P 3 TWD 24 DBH

-1.97 TEC TEH 22 HOT 600UL 44 99 0.26 42 P 3 TWD 18 DBH

-1.79 TEC TEH 22 HOT 600UL 61 99 0.34 140 P 2 TWD 14 VSM

+0.79 TEC TEH 21 HOT 600UL 97 99 0.16 144 P 3 TWD 8 DBH

+0.00 TEH TEC 22 COLD 600UL 139 99 0.27 131 P 2 TWD 13 VH2

-0.98 TEC TEH 61 HOT 600UL 141 99 0.23 106 P 2 TWD 18 VH1

+0.90 TEC TEH 28 HOT 600UL 0.10 13 P 3 TWD 7 DBH

+1.89 TEC TEH 28 HOT 600UL 44 100 0.47 101 P 3 TWD 14 DBH

-1.70 TEC TEH 21 HOT 600UL 52 100 0.47 174 P 3 TWD 14 DBC

-1.85 TEC TEH 21 HOT 600UL 100 100 0.16 33 P 3 TWD 8 DBH

+1.44 TEH TEC 38 COLD 600UL 102 100 0.21 19 P 3 TWD 10 DBH

-1.80 TEH TEC 38 COLD 600UL 132 100 0.74 65 P 2 TWD 27 VH1

-1.19 TEC TEH 61 HOT 600UL 39 101 0.35 17 P 3 TWD 13 DBH

-1.75 TEC TEH 21 HOT 600UL 47 101 0.36 20 P 3 TWD 22 DBC

+1.89 TEC TEH 22 HOT 600UL 49 101 0.37 61 P 3 TWD 14 DBH

-1.70 TEC TEH 21 HOT 600UL S14 101 0.46 139 P 3 TWD 26 DBH

-2.20 TEC TEH 22 HOT 600UL 53 101 0.38 114 P 3 TWD 14 DBH

-1.65 TEC TEH 21 HOT 600UL 83 101 0.29 97 P 2 TWD 13 VSM

+1.36 TEH TEC LOCOK 22 COLD 600UL 127 101 0.48 137 P 2 TWD 19 VH1

-0.75 TEH TEC 22 COLD 600UL 131 101 0.32 94 P 2 TWD 1S VH1

-0.96 TEC TEH 61 HOT 600UL 133 101 0.1S l5l P 2 TWD 1S VH1

+0.66 TEC TEH 28 HOT' 600UL 145 101 0.36 36 P 3 TWD 25 DBC

+1.53 TEC TEH 28

.HOT 600UL 54 102 0.36 138 P 3 TWD 18 DBC

+1.82 TEH TEC 31 COLD 600UL 0.34 148 P 3 TWD 17 DBC

-1.90 TEH TEC 31 COLD 600UL 144 102 0.49 130 P 2 TWD 22 VH2

-0.91 TEC TEH 26 HOT 600UL 0.30 92 P 2 TWD 1S 09H

-1.13 TEC TEH 26 HOT 600UL 41, 103 0.48 75 P 3 TWD 21 DBC

+1.82-TEH TEC 30 COLD 600UL

Framatome ANP Inc.

10/14/04 07:17:53 Customer Name: SONGS Unit 3 Component: S/G 89 Page 13 of 20 MAI, MCI, MMI, MVI, SAI, SCI, SVI, 0-100% TWD QUERY: rpc icodes and 0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 47 103 0.09 19 P 3 TWD 5 DBH

+1.96 TEH TEC 30 COLD 600UL 0.30 32 P 3 TWD 15 DBH

-1.56 TEH TEC 30 COLD 600UL 0.47 31 P 3 TWD 21 DBC

+1.69 TEH TEC 30 COLD 600UL 55 103 0.50 81 P 2 TWD 21 VC3

+1.20 TEH TEC 31 COLD 600UL 83 103 0.59 102 P 2 TWD 24 09H

+1.81 TEH TEC LOCOK 19 COLD 600UL 87 103 0.37 76 P 2 TWD 18 08H

+0.73 TEH TEC 19 COLD 600UL 0.44 134 P 2 TWD 20 09H

+0.73 TEH TEC 19 COLD 600UL 133 103 0.20 103 P 2 TWD 10 VH1

-0.94 TEC TEH 26 HOT 600UL 0.28 112 P 2 TWD 14 08H

+0.88 TEC TEH 26 HOT 600UL 36 104 0.12 37 P 3 TWD 7 DBH

+1.51 TEH TEC 30 COLD 600UL 0.20 57 P 3 TWD 11 DBC

+1.22 TER TEC 30 COLD 600UL 46 104 0.67 88 P 2 TWD 25 VSM

-0.90 TEH TEC 31 COLD 600UL 74 104 0.14 13 P 3 TWD 8 DBC

+0.58 TEH TEC 31 COLD 600UL 88 104 0.27 75 P 2 TWD 13 08H

-0.24 TEH TEC 20 COLD 600UL 0.12 151 P 2 TWD 7 08H

-0.83 TEH TEC 20 COLD 600UL 110__104__0.45__101_P_2__TWO_19__VH2_-0.85___________TE_________TEC________19______COLD________________________

110 104 0.45 101 P 2 TWD 19 VH2

-0.85 TEH TEC 19 COLD 600UL 114 104 0.56 82 P 2 TWD 24 VH2

-0.85 TEH TEC 19 COLD 600UL 138 104 0.43 138 P 2 TWD 20 VH1

-0.88 TEC TEH 26 HOT 600UL 0.13 72 P 2 TWD 8 VH1

-0.19 TEC TEH 26 HOT 600UL 129 105 0.55 96 P 2 TWD 23 VH1

+0.80 TEH TEC 20 COLD 600UL 114 106 0.31 29 P 3 TWD 15 DBH

+2.00 TEH TEC 19 COLD 600UL 144 106 0.56 135 P 3 TWD 30 DBH

-1.98 TEC TEH 26 HOT 600UL 0.23 31 P 3 TWD 16 DBC

-1.60 TEC TEH 26 HOT 600UL 29 107 0.29 114 P 3 TWD 15 DBC

-1.81 TEH TEC 31 COLD 600UL 31 107 0.48 49 P 3 TWD 21 DBH

-1.78 TEH TEC 30 COLD 600UL 0.42 23 2

SAI TSH

-6.37 TSH TSH 0.10 18.21 92 HOT 580PP 37 107 0.86 105 P 2 TWD 29 VSM

-0.80 TEH TEC 31 COLD 600UL 1.22 119 P 2 TWD 35 VSM

+0.72 TEH TEC 31 COLD 600UL 0.44 83 P 2 TWD 19 VSM

-0.16 TEH TEC 31 COLD 600UL 41 107 0.34 26 P 2 TWD 15 VSM

-0.84 TEH TEC 31 COLD 600UL 0.30 114 P 2 TWD 14 VSM

+0.94 TEH TEC 31 COLD 600UL 43 107 0.21 67 P 2 TWO 12 VSM

+0.25 TEH TEC 30 COLD 600UL 0.31 138 P 2 TWD 16 VSM

+0.81 TEH TEC 30 COLD 600UL 0.26 130 P 3 TWD 13 DBC

+1.59 TEH TEC 30 COLD 600UL 83 107 0.24 123 P 2 TWD 13 09H

-1.15 TEH TEC LOCOK 19 COLD 600UL 121 107 0.34 142 P 3 TWD 17 DBH

+2.24 TEH TEC 20 COLD 600UL 133 107 0.13 132 P 2 TWD 8 09H

-0.82 TEC TEH 26 HOT 600UL 0.24 159 P 2 TWD 12 09H

+0.78 TEC TEH 26 HOT 600UL 126 108 0.51 74 P 2 TWD 22 10H

+0.18 TEH TEC 20 COLD 600UL 134 108 0.20 98 P 2 TWD 11 10H

+0.88 TEC TEH 26 HOT 600UL 138 108 0.29 143 P 2 TWD 14 VH2

-1.01 TEC TEH 26 HOT 600UL 14 110 0.15 37 P 3 TWD 8 DBH

-1.27 TEH TEC 31 COLD 600UL 40 110 0.82 126 P 2 TWD 30 VSM

-0.76 TEH TEC 30 COLD 600UL

.0.39 53 P 2 TWD 18 VSM

-0.21 TEH TEC 30 COLD 600UL 0.26 17 P 3 TWD 13 DBC

+1.44 TEH TEC 30 COLD 600UL 74 110 0.45 47 P 2 TWD 19 03H

-0.16 TEH TEC 31 COLD 600UL 128 110 0.25 103 P 2 TWD 12 10H

-0.94 TEH TEC 20 COLD 600UL

Framatome ANP Inc.

10/14/04 07:17:53 Customer Name: SONGS Unit 3 Component: S/G 89 Page 14 of 20 MAI, MCI, MMI, MVI, SAI, SCI, SVI, 0-100% TWD QUERY: rpcqicodes and 0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE


= ---

0.36 130 P 2 TWD 17 10H

+0.96 TEH TEC 20 COLD 600UL 0.24 155 P 2 TWD 12 08H

-0.81 TEH TEC 20 COLD 600UL 132 110 0.31 55 P 2 TWD 12 08H

+0.93 TEC TEH 25 HOT 600UL 0.36 112 P 2 TWD 14 07H

+0.49 TEC TEH 25 HOT 600UL 134 110 0.37 129 P 2 TWD 18 VH2

-0.86 TEC TEH 26 HOT 600UL 47 111 0.37 59 P 2 TWD 18 VSM

+0.33 TEH TEC 30 COLD 600UL 0.97 103 P 2 TWD 33 VSM

+0.91 TEH TEC 30 COLD 600UL 127_1_1_

0.43_ 60_ P 2 =TWO_19_

0.25-----------

TEH--------TEC 19------ COLD----------------------

127 111 0.43 60 P 2 TWD 19 09H

-0.25 TEH TEC 19 COLD 600UL 0.40 72 P 2 TWD 19 10H

+0.35 TEH TEC 19 COLD 600UL 129 111 0.44 126 P 2 TWO 20 09H

-0.86 TEH TEC 20 COLD 600UL 0.32 118 P 2 TWD 15 09H

+0.46 TEH TEC 20 COLD 600UL 44 112 0.29 110 P 2 TWD 15 VSM

-0.82 TEH TEC 30 COLD 600UL 0.16 101 P 2 TWD 9 VSM

+0.19 TEH TEC 30 COLD 600UL 80 112 0.24 18 P 3 TWD 13 DBH

+1.75 TEH TEC 30 COLD 600UL 106 112 0.19 146 P 2 TWD 11 VH2

-0.98 TEH TEC 19 COLD 600UL 0.28 126 P 2 TWO 14 VH2

+0.90 TEH TEC 19 COLD 600UL 120 112 0.45 122 P 2 TWO 20 10H

+1.30 TEH TEC LOCOK 20 COLD 60OUL 0.30 115 P 3 TWO 16 DBH

+0.14 TEH TEC 20 COLD 600UL 122 112 0.43 62 P 2 TWO 19 10H

+0.77 TEH TEC 19 COLD 600UL 140 112 0.39 114 P 2 TWD 19 VH1

-0.91 TEC TEH 26 HOT 60OUL 0.42 24 P 2 TWD 20 04H

+0.93 TEC TEH 26 HOT 600UL 0.36 65 P 3 TWO 23 DBC

-1.75 TEC TEH 26 HOT 600UL 0.34 29 P 3 TWD 22 DBC

+1.61 TEC TEH 26 HOT 600UL 35 113 0.21 22 P 2 TWD 11 VSM

-0.21 TEH TEC 32 COLD 600UL 0.46 86 P 2 TWD 22 VSM

-0.89 TEH TEC 32 COLD 600UL 41 113 0.55 114 P 2 TWD 20 VSM

-0.86 TEH TEC 33 COLD 600UL 0.19 130 P 2 TWD 7 VSM

-0.12 TEH TEC 33 COLD 600UL

_____113__0.36__132_P_2__TWO_17____2_-0.88-----------TEN-----___TEC________19______COLD______________________L_

111 113 0.36 132 P 2 TWD 17 VH2

-0.88 TEH TEC 19 COLD 600UL 0.38 120 P 2 TWO 18 VH2

+0.79 TEH TEC 19 COLD 600UL 121 113 0.36 102 P 2 TWD 17 VH1

-0.78 TEH TEC 20 COLD 600UL 127 113 0.30 79 P 2 TWD 15 08H

+0.87 TEH TEC 19 COLD 600UL 0.29 65 P 2 TWD 15 09H

-0.81 TEH TEC 19 COLD 600UL 44__114__0.40__98__P_2__TWO__20__VSM_-0.88___________TEN________TEC________32______COLD______________________L_

44 114 0.40 98 P 2 TWD 20 VSM

-0.88 TEH TEC 32 COLD 600UL 0.48 92 P 2 TWD 23 VSM

+0.87 TEH TEC 32 COLD 600UL 50 114 1.08 93 P 2 TWD 31 VSM

-0.76 TEH TEC 33 COLD 600UL 0.88 100 P 2 TWD 27 VSM

+0.92 TEH TEC 33 COLD 600UL 114 114 0.55 53 P 2 TWO 23 VH2

-0.88 TEH TEC 19 COLD 600UL 0.27 113 P 2 TWO 14 VH2

+0.94 TEH TEC 19 COLD 600UL 124_____114 _____0.19_____117____P___2___TWO_____10_______H___+0.82______TEH_____TEC____20

____COLD _____________L 124 114 0.19 117 P 2 TWD 10 05H

+0.82 TEH TEC 20 COLD 600UL 126 114 0.35 112 P 2 TWD 17 08H

+0.92 TEH TEC 19 COLD 600UL 136 114 0.28 26 P 3 TWD 19 DBC

+1.16 TEC TEH 26 HOT 600UL 25 115 0.59 112 P 2 TWD 26 VSM

+0.92 TEH TEC 32 COLD 600UL 27 115 0.51 24 2

SAI TSH

-1.70 TSH TSH 0.18 17.83 92 HOT 580PP 83 115 0.48 120 P 2 TWD 24 VSM

+1.25 TEH TEC 17 COLD 600UL 0.65 116 P 2 TWD 29 09H

+2.15 TEH TEC LOCOK 17 COLD 600UL 123_____115_____0.29_____67____P__2___TWO_____16___________+0.42______TEN_____TEC____17____COLD_______________L 123 115 0.29 67 P 2 TWD 16 09H

+0.42 TEH TEC 17 COLD

.600UL 127 115 0.27 43 P 2 TWD 15 08H

-0.48 TEH TEC 17 COLD 600UL 0.29 119 P 2 TWD 17 08H

+0.77 TEH TEC 17 COLD 600UL

I Framatome ANP Inc.

10/14/04 07:17:53 Customer Name: SONGS Unit 3 Component: S/G 89 Page 15 of 20 MAI, MCI, MMI, MVI, SAI, SCI, SVI, 0-100% TWD QUERY: rpcicodes and_0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 137 115 0.26 65 P 2 TWD 14 VH2

-0.99 TEC TEH 26 HOT 600UL 78 116 0.14 174 P 3 TWD 8 DBH

+1.70 TEH TEC 33 COLD 600UL 84 116 0.25 68 P 2 TWD 15 09H

+1.04 TER TEC 17 COLD 60OUL 88 116 0.45 124 P 2 TWD 23 VH2

-0.67 TER TEC 17 COLD 600UL 124 116 0.47 101 P 2 TWD 19 08H

+0.85 TER TEC 18 COLD 600UL 0.32 80 P 2 TWD 15 09H

+0.11 TEN TEC 18 COLD 600UL 0.18 42 P 2 TWD 9 10H

-1.23 TEN TEC 18 COLD 600VL 128 116 0.34 101 P 2 TWD 15 VH1

+0.74 TEH TEC 18 COLD 60OUL 0.28 55 P 2 TWD 13 09C

+0.95 TEN TEC 18 COLD 600UL 39 117 0.42 135 P 2 TWD 18 VSM

-0.76 TER TEC 31 COLD 600UL 105 117 0.25 73 P 3 TWD 12 DBH

+1.42 TEH TEC 18 COLD 600UL 123 117 0.52 139 P 2 TWD 25 09H

-0.62 TEN TEC 17 COLD 600UL 125 117 0.46 133 P 2 TWD 19 08H

+0.76 TEN TEC 18 COLD 600UL 135 117 0.46 160 P 3 TWD 21 DBC

+0.46 TEC TEN 25 HOT 600UL 32__118__0.36_

101__

P_ 2__TD_17______

0.86__

TEN------=

T______C _____30_______COLD_______________________L_

32 118 0.36 101 P 2 TWD 17 VSM

-0.86 TEN TEC 30 COLD 600UL 46 118 0.20 155 P 2 TWD 10 VSM

-0.86 TER TEC 31 COLD 600UL 74 118 0.34 97 P 2 TWD 15 VSM

-0.77 TEH TEC 31 COLD 600UL 102 118 0.51 20 2

SAI TSH

-16.92 TSH TSH 0.17 18.08 144 HOT 580PP 43__119__0.25_______P_2_TWD__13 ______

0.84___________TEN________

TEC_________30_______COLD______________________

43 119 0.25 89I P 2 TWD 13 VSM

-0.84 TEH TEC 30 COLD 600UL

______________0.31

___64 __P __2 __TWO___15________40.72____

TE__ TEC----------31-------COLD---------------_________

45 119 0.42 89 P 2 TWD 18 VSM

-0.86 TEN TEC 31 COLD 600UL 0.31 64 P 2 TWD 15 VSM

+0.72 TEN TEC 31 COLD 600UL 47 119 0.32 32 P 2 TWD 16 VSM

-0.76 TER TEC 30 COLD 600UL 123 119 0.24 126 P 2 TWD 14 09H

-0.13 TEN TEC 17 COLD 600UL 0.46 114 P 2 TWD 23 09H

+0.49 TEN TEC 17 COLD 600UL 48 120 0.25 14 P 2 TWD 12 VSM

-0.84 TER TEC 28 COLD 600UL 0.34 69 P 2 TWD 16 VSM

+0.77 TEN TEC 28 COLD 600UL 122 120 0.24 103 P 2 TWD 14 08H

+0.45 TEN TEC 17 COLD 600UL 0.31 134 P 2 TWD 17 08H

-0.84 TEN TEC 17 COLD 600UL 47 1221 0.44 54 P 2 TWD 20 02H

+0.81 TEN TEC 28 COLD 600UL 99 121 0.36 108 P 2 TWD 20 VH2

-0.98 TEN TEC 17 COLD 600UL 107 121 0.43 20 P 2 TWD 22 VH2

-1.04 TEN TEC 17 COLD 600UL 0.67 154 P 2 TWD 29 VH2

+0.92 TEN TEC 17 COLD 600UL 121 121 0.46 116 P 2 TWD 19 09H

+0.43 TEN TEC 18 COLD 600UL 0.47 706 P 2 TWD 20 VNH

-0.19 TEN TEC 29 COLD 600UL 30 122 0.29 96 P 2 TWD 17 05H

+0.49 TEN TEC 29 COLD 600UL 60 122 0.21 120 P 1 SCI TSH

-0.03 TSH TSH 0.39 18.32 87 HOT 580PP 122 122 0.47 119 P 2 TWD 24 10C

+0.85 TER TEC 17 COLD 600UL 126 122 0.34 98 P 2 TWD 19 VH2 2

TER TEC 17 COLD 600UL 132 122 0.58 33 P 2 TWD 20 VH2

-0.83 TEC TER 25 HOT 600UL 41 123 0.54 96 P 2 TWD 26 VSM

+0.90 TER TEC 29 COLD 600UL 49 123 0.48 151 P 2 TWD 24 08H

+1.56 TEH TEC LOCOR 29 COLD 600UL 57 123 0.74 77 P 2 TWD 31 VH3

-0.86 TER TEC 29 COLD 600UL 107 123 0.12 95 P 3 TWD 7 DBH

-0.42 TER TEC 17 COLD 600UL

Framatome ANP Inc.

10/14/04 07:17:53 Customer Name: SONGS Unit 3 Component: S/G 89 Page 16 of 20 MAI, MCI, MMI, MVI, SAI, SCI, SVI, 0-100% TWD QUERY: rpc icodes and 0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL f LEG PROBE 117 123 0.68 137 P 2 TWD 25 08H

+0.90 TEH TEC 18 COLD 600UL 0.51 101 P 2 TWD 21 06H

+0.87 TEH TEC 18 COLD 600UL 119-123-0.48-66

-p-2-TWD 24


+0.

6

-TEH---TE 17----------------COLD________

=-----------L--

119 123 0.48 66 P 2 TWD 24 09H

+0.76 TEH TEC 17 COLD 600UL 125 123 0.36 65 P 2 TWD 16 05C

+0.75 TEH TEC 18 COLD 600UL 102 124 0.42 114 P 2 TWD 22 VH2

-0.73 TEH TEC 17 COLD 600UL 110 124 0.69 91 P 2 TWD 30 VC2

-0.95 TEH TEC 17 COLD 600UL 0.51 118 P 2 TWD 25 VC2

+0.93 TEH TEC 17 COLD 600UL 112 124 0.74 110 P 2 TWD 26 VH2

-0.98 TEH TEC 18 COLD 600UL 116 124 0.32 80 P 2 TWD 15 09H

+0.76 TEH TEC 18 COLD 600UL 0.27 128 P 2 TWD 13 08H

+0.38 TEH TEC 18 COLD 600UL 0.42 116 P 2 TWD 18 08H

+0.83 TEH TEC 18 COLD 600UL 79 125 0.30 137 P 2 TWD 15 VH3

+0.89 TEH TEC 28 COLD 600UL 0.94 123 P 2 TWD 33 VSM

+0.89 TEH TEC 28 COLD 600UL 107_125_

0.34 70----- P----2 TWO 19--------------+0=----84----TE--------_-EC--_ ----COLD -----------

107 125 0.34 70 P 2 TWD 19 VH2

+0.84 TEH TEC 17 COLD 600UL 117 125 0.36 78 P 2 TWD 16 09H

+0.56 TEH TEC 18 COLD 600UL 0.21 39 P 2 TWD 10 09H

-0.92 TEH TEC 18 COLD 600UL 119 125 0.34 126 P 2 TWD 19 09H

-0.98 TEH TEC 17 COLD 600UL 0.23 51 P 2 TWD 14 09H

+0.17 TEH TEC 17 COLD 600UL 133 125 0.33 134 P 3 TWD 22 DBH

+0.65 TEC TEH 26 HOT 600UL 116 126 0.28 74 P 2 TWD 13 08H

+0.93 TEH TEC 18 COLD 600UL 124 126 0.49 92 P 2 TWD 24 VH2

-0.98 TEH TEC 17 COLD 600UL 69 127 0.26 111 P 2 TWD 15 VSM

+0.81 TEH TEC 29 COLD 600UL 0.43 142 P 2 TWD 22 VC3

-0.76 TEH TEC 29 COLD 600UL 109 127 0.13 130 P 3 TWD 7 DBC

-1.62 TEH TEC 18 COLD 600UL 115 127 0.28 125 P 2 TWD 16 09H

+0.64 TEH TEC 17 COLD 600UL 16 128 0.15 28 P 3 TWD 6 DBH

-0.47 TEH TEC 28 COLD 600UL 38__128__0.22___148__P _2 __TWO __13 __V __

=--0 ----

7 TEH--------TEC 29------ COLD--------------------L-38 128 0.22 148 P 2 TWD 13 VSM

+0.70 TEH TEC 29 COLD 600UL

_________________0.52_____117_____P__2___TWO_____23_______M____0___81____TE_______EC___28____COLD_____________L 44 128 0.39 153 P 2 TWD 18 VSM

-0.78 TEH TEC 28 COLD 600UL 0.52 117 P 2 TWD 23 VSM

+0.81 TEH TEC 28 COLD 600UL 116 128 0.29 103 P 2 TWD 14 09H

-0.80 TEH TEC 18 COLD 600UL 0.55 108 P 2 TWD 22 09H

+0.60 TEH TEC L2 COLD 600UL 0.45 148 P 2 TWD 19 08H

+0.92 TEH TEC 18 COLD 600UL 49 129 0.34 86 P 2 TWD 19 08H

-1.55 TEH TEC LOCOK 29 COLD 600UL 51 129 0.36 65 P 2 TWD 18 08H

+0.73 TEH TEC 28 COLD 600UL 0.14 128 P 2 SCI TSC

+0.06 TSC TSC

.24 61 COLD 580PP 57 129 0.27 150 P 3 TWD 15 DBH

+0.00 TEH TEC 29 COLD 600UL 79 129 0.52 146 P 2 TWD 23 VSM

+0.83 TEH TEC 28 COLD 600UL 0.83 116 P 2 TWD 30 VH3

+0.85 TEH TEC 28 COLD 600UL 0.43 147 P 2 TWD 20 VSM

-0.93 TEH TEC 28 COLD 600UL 85 129 0.38 34 P 2 TWD 20 VH2

+0.85 TEH TEC 17 COLD 600UL 113 129 0.40 44 P 2 TWD 21 09H

+0.86 TEH TEC 17 COLD 600UL 0.38 122 P 2 TWD 20 VH2

+0.88 TEH TEC 17 COLD 600UL 0.31 76 P 3 TWD 17 DBH

+1.96 TEH TEC 17 COLD 600UL 115 129 0.38 80 P 2 TWD 17 09H

-0.89 TEH TEC 18 COLD 600UL 117 129 0.21 96 P 2 TWD 12 08H

+0.97 TEH TEC 17 COLD 600UL 52 130 0.42 47 P 2 TWD 19 01H

+0.87 TEC TEH 17 HOT 600UL

Framatome ANP Inc.

10/14/04 07:17:53 Customer Name: SONGS Unit 3 Component: S/G 89 Page 17 of 20 MAI, MCI, MMI, MVI, SAI, SCr, SVI, 0-100% TWD QUERY: rpc_icodesand_0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 100 130 0.40 124 P 2 TWD 19 VH2

-0.84 TEC TEH 3

HOT 600UL 114 130 0.23 95 P 2 TWD 16 09H

-0.89 TEC TEH 4

HOT 600UL 41 131 0.39 131 P 2 TWD 26 VSM

-0.76 TEC TER 18 HOT 600UL 0.42 123 P 2 TWD 27 VSM

+0.70 TEC TER 18 HOT 600UL 43 131 0.44 81 P 2 TWD 20 VSM

+0.85 TEC TEH 17 HOT 600UL 45____131_____0.________129_____P2____T___D___30____VSM_______0.70______T___C___T_______18____HOT_____________L 45 131 0.49 129 P 2 TWD 30 VSM

+0.70 TEC TER 18

'HOT 600UL 0.26 150 P 2 TWD 20 VSM

-0.89 TEC TEA 18 HOT 600UL 65 131 0.36 32 P 2 TWD 25 02H

-1.25 TEC TEH 18 HOT 600UL

__1__131__0.14__89__P_2_TWD__10______-0.82___________TEC_________TE_________46_______HOT_______________________

111 131 0.14 89 P 2 TWD 10 08H

-0.82 TEC TER 46 HOT 600UL 0.17 89 P 2 TWD 12 08H

+0.78 TEC TEH 46 HOT 600UL 0.20 130 P 2 TWD 14 VH2

-0.82 TEC TEH 46 HOT 600UL 127 131 0.13 35 P 3 TWD 11 DBH

+1.76 TEC TEH 4

HOT 600UL 68____132_____0.56______82____P___2___TWO_____24____VC3_____+0.77_______TEC_____TE______17____HOT______________

68 132 0.56 82 P 2 TWD 24 VC3

+0.77 TEC TER 17 HOT 600UL 76 132 0.28 113 P 2 TWD 15 VH3

-0.75 TEC TEH 17 HOT 600UL 112 132 0.34 137 P 2 TWD 21 08H

+0.80 TEC TEA 4

HOT 600UL 0.43 88 P 2 TWD 25 07H

+0;89 TEC TEA 4

HOT 600UL 114 132 0.81 123 P 2 TWD 29 07H

+0.75 TEC TEA 3

HOT 600UL 45 133 0.16 92 P 3 TWD 7 DBC

-1.09 TEC TEA 17 HOT 600UL 47__133__0.55__104__P2__TAD__31___S__-0.78___________TEC____________EA______18_______HOT_____________________L_

47 133 0.55 104 P 2 TWD 31 VSM

-0.78 TEC TEA 18 HOT 600UL 0.56 129 P 2 TWD 32 VSM

+0.00 TEC TEA 18 HOT 600UL 0.48 117 P 2 TWD 29 VSM

+0.73 TEC TEA 18 HOT 600UL 71 133 0.35 145 P 2 TWD 24 VH3

+0.70 TEC TER 18 HOT 600UL 0.40 100 P 2 TWD 26 VH3

-0.88 TEC TEA 18 HOT 600UL 0.32 151 P 2 TWD 23 VC3

-0.64 TEC TEA 18 HOT 600UL 0.18 12 P 2 TWD 16 VC3

-0.16 TEC TEA 18 HOT 600UL 111 133 0.31 121 P 2 TWD 15 08H

+0.81 TEC TEH 3

HOT 600UL 44 134 0.23 52 P 2 TWD 13 VSM

-0.71 TEC TEH 17 HOT 600UL 76 134 0.20 160 P 3 TWD 9 DBC

-2.09 TEC TEA 17 HOT 600UL 108 134 0.23 102 P 2 TWD 18 VH2

-0.86 TEC TEA 4

HOT 600UL 65 135 0.43 10 P 3 TWD 16 DBC

+1.96 TEC TEA 17 HOT 600UL 111 135 0.26 63 P 2 TWD 14 VH2

+0.24 TEC TEA 3

HOT 600UL 56 136 0.33 184 P 2 TWD 16 VSM

+0.79 TEC TEH 17 HOT 600UL 0.42 82 P 2 TWD 20 VSM

-0.79 TEC TEA 17 HOT 600UL l10 136 0.33 142 P 2 TWD 16 08H

+0.94 TEC TEA 3

HOT 600UL 0.32 42 P 2 TWD 16 08H

-0.84 TEC TEA 3

HOT 600UL 89 137 0.43 113 P 3 TWD 17 DBH

+1.43 TEC TEA 3

HOT 600UL 0.36 124 P 2 TWD 17 VH2

+0.91 TEC TEA 3

HOT 600UL 0.39 84 P 2 TWD 18 VH2

-0.96 TEC TER 3

NOT 600UL 91 137 0.18 60 P 3 TWD 14 DBH

+1.75 TEC TER 4

HOT 600UL 109 137 0.23 123 P 2 TWD 12 08H

+0.98 TEC TEA 3

HOT 600UL 0.57 84 P 2 TWD 24 08H

-0.83 TEC TEA 3

HOT 600UL 111 137 0.38 128 P 2 TWD 23 VH2

+1.05 TEC TER 4

HOT 600UL 46 138 0.28 105 P 2 TWD 21 04C

-0.14 TEC TER 18 HOT 600UL 108 138 0.22 122 P 2 TWD 12 08H

-0.98 TEC TER 3

HOT 600UL 110 138 0.20 75 P 2 TWD 14 08H

+0.00 TEC TER 4

,HOT

.600UL

Framatome ANP Inc.

10/14/04 07:17:53 Customer Name: SONGS Unit 3 Component: S/G 89 Page 18 of 20 MAI, MCI, MMI, MVI, SAI, SCI, SVI, 0-100% TWD QUERY: rpc icodes and 0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL f LEG PROBE

"______w___

107 139 0.32 104 P 2 TWD 20 09H

+0.52 TEC TEH 4

HOT 600UL 109 139 0.14 170 P 3 TWD 6 DBH

+1.61 TEC TEH 3

HOT 600UL 119 139 0.40 120 P 2 TWD 24 10C

-1.31 TEC TEH LOCOK 4

HOT 600UL 74 140 0.17 146 P 2 TWD 12 VC3

+0.77 TEC TEH 14 HOT 600UL 111 141 0.29 80 P 3 TWD 12 DBH

-1.57 TEC TEH 3

HOT 600UL 106 142 0.89 110 P 2 TWD 31 VH2

-0.88 TEC TEH 3

HOT 600UL 112 142 0.31 0

P 3 TWD 21 DBC

+1.88 TEC TEH 4

HOT 600UL 0.27 161 P 2 TWD 18 VC2

-0.94 TEC TEH 4

HOT 600UL 57 143 0.52 83 P 2 TWD 22 VH3

+0.73 TEC TEH 13 HOT 600UL 111 143 0.19 130 P 2 TWD 14 VC3

+0.76 TEC TEH 4

HOT 600UL 36 144 0.25 119 P 2 TWD 17 VSM

-1.00 TEC TEH 14 HOT 600UL 42 144 0.44 85 P 2 TWD 19 VSM

+0.89 TEC TEH 13 HOT 600UL 86 144 0.42 38 P 2 TWD 19 VH2

+0.83 TEC TEH 3

HOT 600UL 98 144 0.25 79 P 2 TWD 12 09H

-0.84 TEC TEH 3

HOT 600UL 37 145 0.37 97 P 2 TWD 17 VSM

+0.98 TEC TEH 13 HOT 600UL 43 145 0.63 106 P 2 TWD 31 VSM

+0.65 TEC TEH 14 HOT 600UL 0.25 140 P 2 TWD 17 VSM

-0.93 TEC TEH 14 HOT 600UL 49 145 0.21 15 P 3 TWD 14 DBC

+1.82 TEC TEH 14 HOT 600UL 67 145 0.44 133 P 2 TWD 20 VC3

+1.16 TEC TEH 13 HOT 600UL 107 145 0.19 96 P 2 TWD 14 08H

-0.02 TEC TEH 4

HOT 600UL 30 146 0.54 31 P 1 SCI TSH

-0.14 TSH TSH 0.28 17.89 110 HOT 580PP 36_____146_____0.23______73__________TW______12____________+0____82____TEC_____TE______13____HOT_______________

36 146 0.23 73 P 2 TWD 12 VSM

+0.82 TEC TEH 13 HOT 600UL 40 146 0.32 43 P 2 TWD 15 VSM

+0.86 TEC TEH 13 HOT 600UL 46 146 0.41 117 P 2 TWD 24 VSM

+0.99 TEC TEH 14 HOT 600UL 0.47 126 P 2 TWD 26 VSM

-0.80 TEC TEH 14 HOT 600UL 76 146 0.40 39 P 2 TWD 18 VH3

+0.73 TEC TEH 13 HOT 600UL 0.45 112 P 2 TWD 20 VH3

-0.75 TEC TEH 13 HOT 600UL 102__146__0.26__134_p_2__TWO_________-0.83____________TEC_________TEH_________5_____HOT________________________

102 146 0.26 134 P 2 TWD 11 VH2

-0.83 TEC TEH 5

HOT 600UL 106 146 0.34 105 P 2 TWD 14 VH2

-0.84 TEC TEH 5

HOT 600UL 39 147 0.33 127 P 2 TWD 16 VSM

+0.90 TEC TEH 13 HOT 600UL 75 147 0.54 75 P 2 TWD 23 VC3

+0.69 TEC TEH 13 HOT 600UL 105 147 0.56 118 P 2 TWD 21 VH2

-0.83 TEC TEH 5

HOT 60OUL 34 148 0.28 158 P 2 TWD 18 VSM

-0.84 TEC TEH 14 HOT 600UL 42 148 0.19 111 P 2 TWD 13 VSM

+0.82 TEC TEH 14 HOT 600UL 0.34 148 P 2 TWD 21 VSM

+0.14 TEC TEH 14 HOT 600UL 58 148 0.35 135 P 2 TWD 21 VSM

+0.65 TEC TEH 14 HOT 600UL 0.27 97 P 2 TWD 18 VC3

-1.02 TEC TEH 14 HOT 600UL 90 148 0.49 96 P 2 TWD 19 VH2

-0.72 TEC TEH 5

HOT 600UL 102 148 0.45 43 P 2 TWD 18 VH2

+0.69 TEC TEH S

HOT 600UL 103 149 0.36 125 P 2 TWD 23 08H

-0.13 TEC TEH 6

HOT 600UL 102 150 0.15 18 P 3 TWD 13 DBC

+1.97 TEC TEH 6

HOT 600UL

Framatome ANP Inc.

10/14/04 07:17:54 Customer Name: SONGS Unit 3 Component: S/G 89 Page 19 of 20 MAI, MCI, MMI, MVI, SAI, SCI, SVI, 0-100% TWD QUERY: rpc icodes and_0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 65 151 0.28 23 P 2 TWD 14 VSM

-0.95 TEC TEH 13 HOT 600UL 0.38 120 P 2 TWD 17 VSM

+0.99 TEC TEH 13 HOT 600UL 0.17 163 P 2 TWD 8 VSM*

+0.14 TEC TEH 13 HOT 600UL 99 151 0.24 145 P 2 TWD 17 08H

-0.91 TEC TEH 6

HOT 600UL 66 152 0.31 138 P 2 TWD 20 VH3

-0.65 TEC TEH 14 HOT 600UL 76 152 0.24 71 P 2 TWD 12 VC3

-0.59 TEC TER 13 HOT 600UL 80 152 0.21 52 P 3 TWD 9 DBC

+1.75 TEC TEH 13 HOT 600UL 81____153_____0.43______103_____p___2___TW______17______________0___9_____T___d___TE______5___HOT______________

81 153 0.43 103 P 2 TWD 17 VH3

+0.91 TEC TER 5

HOT 600UL 0.25 101 P 2 TWD 11 VH3

-0.87 TEC TEH 5

HOT 600UL 0.15 39 P 3 TWD 6 DBC

+1.78 TEC TEH 5

HOT 600UL 67 155 0.20 135 P 2 TWD 15 VSM

+0.67 TEC TEH 10 HOT 600UL 77 155 0.69 115 P 2 TWD 26 VH3

+0.76 TEC TER 9

HOT 600UL 0.44 124 P 2 TWD 19 VH3

-0.99 TEC TEH 9

HOT 600UL 86 156 0.36 37 P 2 TWD 16 VH2

-0.71 TEC TER 5

HOT 600UL 37 157 0.22 37 P 2 TWD 11 VSM

+0.73 TEC TER 9

HOT 600UL 41 157 0.49 120 P 2 TWD 21 VSM

+0.72 TEC TEH 9

HOT 600UL 73 157 0.21 86 P 2 TWD 11 VC3

+0.91 TEC TEH 9

HOT 600UL 87 157 0.32 137 P 2 TWD 15 03H

-1.19 TEC TER 5

HOT 600UL 44 158 0.30 128 P 2 TWD 14 VSM

+0.92 TEC TER 9

HOT 600UL 0.16 127 P 2 TWD 9 VSM

-0.08 TEC TER 9

HOT 600UL 0.33 84 P 2 TWD 16 VSM

-0.78 TEC TEH 9

HOT 600UL 54 158 0.18 124 P 2 TWD 14 VSM

+0.76 TEC TER 10 HOT 600UL 68 158 0.59 109 P 2 TWD 23 VH3

-0.04 TEC TER 9

HOT 600UL 78__158__0.31__147__p_2_TWO__21______-0.85___________TEC_________TEH________10_______HOT_______________________

78 158 0.31 147 P 2 TWD 21 VH3

-0.85 TEC TEH 10 HOT 600UL 43 159 0.31 22 P 2 TWO 21 02H

-0.85 TEC TEH 10 HOT 600UL 68__160__0.59________

2__TWO__24 ___H3 _

0.04___

TEC__________

T_______________9______HOT________________________

66 160 0.30 111 P 2 TWD 20 VH3

-+0.81 TEC TER 10 HOT 600UL 68 160 0.59 131-P 2 TWD 24 VH3

-0.04 TEC TER 9

HOT 600UL 78 160 0.54 131 P 2 TWD 30 VH3

-0.92 TEC TER 10 HOT 600UL

=

38 162 0.21 151 P 2 TWD 16 VSM

-0.75 TEC TEH 10 HOT 600UL 0.20 99 P 2 TWD 15 VSM

-0.06 TEC TER 10 HOT 600UL 40 162 0.21 57 P 2 TWD 11 VSM

-0.08 TEC TEH 9

HOT 600UL 0.34 79 P 2 TWD 16 VSM

-0.69 TEC TER 9

HOT 600UL 60____164_____0.18________5_____P___2__TWO_____14____________+0.77_______TEC____TE______10____HOT______________

58 162 0.18 131 P 2 TWD 14 VH3

-0.79 TEC TEH 10 HOT 600UL 62 162 0.20 68 P 2 TWD 15 VH3

-+.90 TEC TER 10 HOT 600UL 76 162 0.24 71 P 2 TWD 12 08H

+1.00 TEC TEH 9

HOT 600UL 71 163 0.13-44 P 2 TWD 11 02C

+0.08 TEC TER 10 HOT 600UL 46 164 0.15 60 P 2 TWD 12 VSM

-0.17 TEC TEH 10 HOT 600UL 0.24 152 P 2 TWD 17 VSM

-0.75 TEC TER 10 HOT 600UL 60 164 0.18 155 P 2 TWD 14 08C

+0.77 TEC TER 10 HOT 600UL 68 164 0.34 128 P 2 TWD 22 VH3

-0.79 TEC TER 10 HOT 600UL 0.32 100 P 2 TWD 22 01C

+0.86 TEC TEH 10 HOT 600UL-0.17 102 P 2 TWD 13 01C

-0.08 TEC TER 10 HOT 600UL 55 165 0.19 133 P 2 TWD 14 VH3

-0.94 TEC TER 10 HOT 600UL 67 165 0.70 102 P 2 TWD 26 01C

-0.08 TEC TER 9

HOT 600UL

Framatome ANP Inc.

10/14/04 07:17:54 Customer Name: SONGS Unit 3 Component: S/G 89 Page 20 of 20 MAI, MCI, MMI, MVI, SAI, SC}, SVI, 0-100% TWD QUERY: rpc icodes and_0-100%twd.qry ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 2

1-.

87-P-- 2--

13- ----

40.88 TEC

_,E_

46

  • OT,_

20 166 0.25 87 P 2 TWD 13 02H

+0.88 TEC TEH 46 HOT 600UL

__________0.28

_107 _P_2 _TWO _19 __-

_____-0.98_TE-C___

___6 H-_T____-

62 166 0.20 120 P 2 TWD 15 02H

-0.27 TEC TEH 6

HOT 600UL 0.28 107 P 2 TWD 19 02H

-0.98 TEC TEH 6

HOT 600UL 64 166 0.24 19 P 2 TWD 11 07H

+0.67 TEC TEH 5

HOT 600UL 45 167 0.19 534 P 2 TWD 17 VSM

+0.98 TEC TEH 46 HOT 600UL 40 168 0.53 50 P 2 TWD 23 VSM

+0.88 TEC TEH 46 HOT 600UL 0.18 155 P 2 TWD 10 VSM

-0.74 TEC TEH 46 HOT 600UL 0.23 135 P 2 TWD 12 VSM

-0.16 TEC TEH 46 HOT 600UL 45 169 0.34 53 P 2 TWD 17 01C

+0.98 TEC TEH 46 HOT 600UL 37__171__0_52___10__P_2_TWO__20______-0.82____________T_____C________E________5_____HOT________________________

22 1'70 0.23 56 P 2 TWD 10 01C

+0.88 TEC TEH S

HOT 600UL 40 170 0.31 139 P 2 TWD 21 01C

+0.88 TEC TEH 6

HOT 600UL 42 170 0.20 83 P 2 TWD 8 01H

-0.13 TEC TEH 5

HOT 600UL 46 170 0.23 41 P 2 TWD 10 05C

+0.84 TEC TEH 5

HOT 600UL 33 171 0.38 133 P 2 TWD 16 01C

-0.51 TEC TEH.

5 HOT 600UL 37 171 0.52 110 P 2 TWD 20 VSM

-0.82 TEC TEH 5

HOT 600UL Total Tubes

606 Total Records: 789