Draft Submittal
WATTS BAR JULY 2004 EXAM
50-390/2004-301
JULY 23, & JULY 26-30,2004
Administrative Topics Qdtline
Form ES-301-1
Describe activity to be performed:
Calculate target boron concentration for load escalation using Appendix
E Of Sol-62.02. (NEW) [G 2.1.25, 2.8/3.1]
Operating Test Number
Calculate QPPR using Surveillance instruction I-SI-0-21. (0) [G 2.2.12,
3.013.4J
Evaluate RADCON survey map to determine posting requirements. (D)
[G 2.3.1, 2.6/3.0]
Medical Emergency Response. (D) (6
2.4.39,
3.3)
NUREG-1021, Draft Revision 9
Adminisbative Topics Outline
Form ES-301-1
Facility:
WATTS BAR
Date of Examination: 7/26 - 713012004
Operating Test Number
1 Conduct of Operations
1
Describe activity to be performed:
Calculate target boron concentration for load escalation using Appendir
E Of SOi-62.02. (NEW) [G 2.1.25, 2.8/3.1]
Obtain and verify controlled procedure copy using Curator1BSL.
(8)
[G 2.2.21, 3113.21
Calculate QPTR using Surveillance instruction 1-SI-0-21. (5) [G 2.2.12,
3,013.41
Radiation Control
Evaluate RADCON survey map to determine posting requirements. (B)
- G2.3.1, 2.6/3.01
2iassify the event in accordance with the Radiological Emergency Plan
- REP). -(NEW) [G 2.4.38, 4.01
NUREG-1021, Draft Revision 9
A. 1 .a ROISRO
Page 1 of 12
REGION II
INITIAL LICENSE EXAMINATION
ADMINISTRATIVE JOB PERFORMANCE MEASURE
A.1 .a RO/SRO JPMRADMIN
Calculate Target Boron Cb for Load Escalation
Using Appendix E of Sol-62.02
APPLICANT
EXAMlNER
A.1.a RBlSRO
Page 2 of 12
REGION lI
INITIAL LKENSE EXAMINATION
ADMINISTRATIVE JOB PERFORMANCE MEASURE
Task: Calculate Target Boron Cb for Load Escalation Using Appendix E of Sol-62.82
Alternate Path:
NIB
Facilitv JPM #:
New
KIA Ratinds):
G2.1.25
[2.8/3.1]
Task Standard:
Performer completes a calculation for Target Boron Concentration per Sol-62.02,
Appendix E Reactivity balance calculation. Target RCS Boron Concentration is
determined. Performer notifies SM/Unit Supervisor of the results.
Preferred Evaluation Location:
Preferred Evaluation Method:
Simulator
In-Plant -
Perform
X
Simulate ~
References: Sol-62.02, Boron Concentration Control, Rev. 39; NUPOQ, WCAP-16134,
Nuclear Parameters and Operating Package for Watts Bar Unit 1. Cycle 6,
Rev 0.
Task Number:
RO-062-SOI-62-016
APPLICABLE FOR: RO/SRO
Examiner:
I
NAME
SIGNATURE
DATE
COMMENTS
A. 1 .a ROlSRO
Page 3 of 12
ToolsiEsuipmenffPrece~ure~
Needed:
Latest revision of Sol-62.02
~
~
NUPOP for WBN Unit 1 Cycle 5
NOB for WBN Unit I
Ruler or straight edge.
Calculator
NOTE: START THIS JPM AT A LOCATiON WHERE PERFORMER HAS ACCESS
TO PROCEDURES (Simulator, Main Control Room, TIC or provide
performer with procedure).
READ TO OPERATOR
DIRECTION TO TRAINEE:
I will explain the initial conditions, and state the administrative task to be
performed. I will provide initiating cues and reports on other actions when
directed by you. Ensure you indicate to me when you understand your assigned
task. To indicate that you have completed your assigned task return the handout
sheet I provided you.
(NITIAL CONDITIONS:
The Unit is operating at 79% rated thermal Power.
Core average bumup is 13000 MWDiMTU
Control Bank "D" rods are at 190 steps.
RCS Boron Concentration is 615
Target Rod Position at 100% RTP will be 220 Steps on Control Bank "B"
Power will be raised 3% Der hour.
Xenon printout from REACTINW has been performed by an STA.
You are an extra Unit Operator.
INITIATING CUES:
Using the information provided, the SMlUnit SRO has directed you to calcuate
Target Boron Centration for raising power to 100% per Sol-62.01 Appendix E
"Reactivity balance Calculation"
rn
Determine the RCS Target Boron concentration.
a
Notify SMIUnit SRO of the RCS Target Boron Concentration.
A. 1 .a ROiSRO
Page 4 of 12
START TIME:
STEP 1:
STANDARD:
Obtain a copy of the instruction.
A copy of Sol-62.02 Appendix E "Reactivity Balance Calculation"
has been obtained.
EXAMINER'S CUE: Provide the applicant a copy of the instruction.
COMMENTS:
NOTE 1
One calculation is required for each major change. Calculation is
an approximation of Final Target Boron CB. Rough interpolation of
NuPop figures is acceptable and expected.
Dilution or Boration value for power change from P, YC to Pz YO
power in the time period T with rods moving from step position R1
to R2. (Subscript convention: 1 = current point, 2 = target point)
Evaluator Note. JPM Steps 2 through 6 evaluate applicants completion
of the first page of Appendix E.
NOTE 2
STEP 2: [I]
CALCULATE target boron concentration by performing the
following:
Obtains: Current RCS Boron CB:
PPM.
CUE: When CHEM LAB notified, acknowledge request, then report
current RCS Boron Concentrations is 615
STANDARD: Applicant contacts Chem Lab for current boron concentration
(Value provided on task assignment sheet.
COMMENTS:
_____ UNSAT
-
-
UNS T
- Italicized Cues Are To Be Used Only If JPM Performance is Being Sirnuiated.
A.1.a RQiSRO
Page 5 of 12
STEP 3:
Obtains: Core Burnup:
MWDIMTU
STANDARD: Applicant determibes current core burnup from task
assignment sheet. 'i 3000 MWDIMTU. (ICS point display
U7981 or Other ICs dispays that indicate core burnup Le.,
Xenon (Core burnup is provided on task assignment sheet).
COMMENTS:
STEP 4:
Obtains:
Current Reactor power = PI:
Target Reactor power = P2:
YO
%
Calculates: Total Reactor power change:
A%
STANDARD: Applicant determines current reactor power and target power
from information provided on assignment sheet. P I = 79%.
P2 =
assignment. Applicant determines total power change to be
-
21%.
Target reactor power was given on task
COMMENTS:
-
-
UNSAT
-
§AT
__ UNSAT
- Italicized Cues Are To Be Used Only If JPM Performance is Being Simulat@d.
A.7.a R01SRO
Page 6 of 12
STEP 5:
0 btains:
Rate of Reactor Power change:
%Ihr
Number of hours to change power:
w-4
STANDARD: Applicant determines rate of reactor power change from task
assignment to be 3 YO per hour. Applicant calculates number
of hours projected to reach target power as 7 hrs.
COMMENTS:
STEP 6:
Qbtains:
Current Rod Position:
steps
Final Bod Position:
steps
STANDARD: Applicant determines final rod position from task assignment
as 220 Steps.. Applicant determines current rod position from
ICs or Control Board Step Counters (Value provided on task
assignment sheet). Value for current position is 190 steps.
COMMENTS:
-
-
UNSAT
-
-
U N SAT
- italicized Cues Are TO Be Used On/y If JPM Performance Is Being Simulated.
A.1.a ROISRB
Page 7 of 12
CAUTION
Follow sign conventions explicity.
Evaluator Note. JPM Steps 7 through 11 evaiuate applicants completion
-
of the second page of Appendix E steps for Reactivity Balance.
STEP 7: Determines Ap Power Defect:
Power Defect 1 , ~ : From NUPOP, Figure 6-18, 19, or 20.
pcm PI3 -
pcm PD2 =
Pcm
Ap Power Defect
STANDARD: Applicant determines the PD1 for current power level is -2225
pcm (accept 2280 to 2250 pcm) from figure 6-20, and
determines PD2 for target power level as -2750 pcm (accept
2725 to 2775) from figure 6-20, and enters the values in
appropriate table locations. Applicant then calculates Ap
Power Defect by subtracting algebraically PD:! from PDI. The
value determined is S p c m (accept 500 to 550).
COMMENTS:
CRlTlCAb
STEP
-
-
UNSAT
- italicized Cues Are To Be Used Oniy If JPM Performance Is Being .Simu/ated.
A.1.a ROISRO
Page 8 of 12
STEP 8: Determines Ap Xenon:
Xenonr: From WEACTW (either current conditions or projection to
initial condition).
pcm XEI.
Xenon2: From REACTW (projected over time period T).
pcm XE2.
NOTE: Xenon Values must be negative.
Applicant than calculates Ap Xenon by subtracting algebraically XE2
from XEl.
-2704.5 pcm XEr - -2568.5 pcm XE2 =
gcm
(current)
(Target)
Ap Xenon
STANDARD: Applicant determines the XE1 for current power level is -2704.5
pcm from Xenon REACTW printout, and determines XE2 fer
target power level as -2568.5 pcm from the same printout, and
enters the values in appropriate table locations. Applicant then
calculates Ap Xenon by subtracting algebraically XE2 from XE,.
The value determined is a
pcrn.
COMMENTS:
STEP 9 Determines Ap rods:
Rods 1, 2 : From NUPOP, Figure 6-24, or 25.
pcm Kods, -
pcm Rods2 =
pcm
(current)
(Target)
Ap Rods
STANDARD: Applicant determines the Rods1 for current rod position as 220
pcm (accept 205 - 235) from NUPOP Figure 6-25, and
determines Rods2 for target as a
(accept 0 - 35) pcm from
the same figure, and enters the values in appropriate table
locations. Applicant then calculates Ap Rods by subtracting
algebraicaily Rods2 from Rods,. The value determined is 215
pcm. (accept 280 - 230)
COMMENTS:
CRITICAL
STEP
_I SAT
UNSAT
CRITICAL
STEP
-
-
UNSAT
- italicized Cues Are To Be Used Oniy If JPM Petformanee Ls B@hg Simulated.
STEP 10: Determines p boronl:
Current RCS Boron X 1000 + Inverse Boron Worth NUPOP, Figure
6-21).
Boron X (m
+
pcm/%Ap) =
Pcm
(current)
p BQRON,
STANDARD: Applicant enters m g p m for current boron concentration.
Applicant determines the inverse boron worth is
_1pcml%Ap
(accept 157 -159) from NUQOP Figure 6-21 for
the current boron concentration, and enters the values in
appropriate table location. Applicant then calculates p
BORON, by multiplying RCS boron concentration by the
product of 1000 pcm divided by current inverse boron worth
boron worth determined from figure 6-21 for the current RCS
boron concentration. p boron 1 value is calculated is minus
3897.338 pcm. (Accept -3872 to -4922)
p BORON,
COMMENTS:
A.1.a ROlSRO
Page 9 of 22
CRITICAL
STEP
-
-
UNSAT
- italicized Cues Are To Be Used only If JPM Performance Is Being Simulated.
A.1.a ROiSRO
Page 10 of 12
STEP 11: Determines p boron2:
Calculates p boron;? by
Ap Power Defect + __ pcrn Ap Xenon - __ pcrn +
pcm (p BORON$, =
Pcm
p BORON2
STANDARD: Applicant calculates p boron;! by by algebraically
addinglsubtracting the change in power defect, change in
Xenon reactivity, change in reactivity due to rods and current
worth of RCS boron. The result of the calculation in reactivity
required by boron at the target power level. The values
previously calculated are entered into the table observing
proper signs.
+ s p c m (Ap Xenon)
- -
210 pcm (Ap Rods)
+ -3897.338 gcrn (p BORON1, = -3718.338 pcm
(Accept -3693 to -3743)
+ m p c m (Ap Power Defect )
p BORON2
COMMENTS:
Evaluator Note. JPM Steps 22 evaluate applicants completion of the
second page of Appendix E steps for Target PPM.
STEP 12: (
pcmpBORON2 X (
pprnl%Ap Inverse Boron
Worth +
pcrn/%Ap) =
P W
STANDARD: Applicant determinesTarget Boron Concentration by taking p
B0K0N2 times born worth and conversion factor. The target
boron concentration is calculated to be 586 pprn. (Accept 566
to 606)
COMMENTS:
CRITICAL
STEP
-
-
UNSAT
CRITICAL
STEP
-
-
UNSAT
- /talicized Cues Are To Be Used Only I f JPM Performance Is Being Simuiated.
STEP 13:
NOTIFY SMlUnit SRO of RGS Parget Boron Centration
calculated.
EVALUATOR CUE: Role play as SMlUnit supervisor and acknowledge
report. Acknowledge request for independent
verification, State that this Admin JPM has been
completed. W e will stop here.
STANDARD: Applicant informs the SMlUnit Supervisor of the Target RCS
boron concentration that was calculated. Should also inform
him that acceptance criteria for this SI were not met.
COMMENTS:
__ SAT
-
UNSAT
END OF TASK
TIME STOP:
- Italicized Cues Are TO Be Used Only If JPM Performance Is Being Sirnulafed.
APPLICANT CUE SHEET
(TO BE RETURNED YO EXAMINER UPON COMPLETION OF TASK)
DIRECTION TO TRAINEE:.
I will explain the initial conditions, and state the administrative task to be
performed. I will provide initiating cues and reports on other actions when
directed by you. Ensure you indicate to me when you understand your assigned
task. To indicate that you have completed your assigned task return the handout
sheet I provided you.
INlTlAL CONDITIONS:
The Unit is operating at 79% rated thermal Power
Core average burnup is 13000 MWDIMTU.
Control Bank D rods are at 190 steps.
RCS Boron Concentration is 615
Target Rod Position at 100% RTP will be 220 Steps on Control Bank D
Power will be raised 3% per hour.
Xenon printout from REACTINW has been performed by an STA
You are an extra Unit Operator.
INITlATlNG CUES:
Using the information provided, the SMlUnit SRO has directed you to calcuate
Target Boron Centration for raising power to 100% per SO!-62.01 Appendix E
Reactivity balance Calculation
Determine the RCS Target Boron concentration.
Notify SMlUnit SRO of the RCS Target Boron Concentration.
[REACTW -
TIME
(HRSO
.o
1 .o
2.0
3.0
4.0
5.0
6.0
7.0
'VERS WB2.11
POWR
79.0
82.0
85.0
88.0
91 .o
94.0
97.0
100.0
(c/o)
XENON CALCULATION
WATTS EAR UNIT 1 CYCLE 6
BOL NIX XENON DATA
XE
I
(% EQ)
(% EQ)
93.0
79.0
92.6
79.3
92.0
79.9
91.2
80.9
90.4
81.7
89.6
82.9
88.9
84.3
88.3
85.9
XE
WORTH
(PCM)
-2704.5
-2693.2
-2674.9
-2652.9
-2629.7
-2607.1
-2586.4
-2568.5
DEL XE
WORTH
.o
11.3
18.3
22.0
23.2
22.6
20.7
17.9
( P W
JPMRADMIN A.1.b
Page 1 of 8
REGION II
INITIAL LICENSE EXAMINATION
ADMlNlSTRATlVE JOB PERFORMANCE MEASURE
A.l .b JPMRADMIN
OBTAIN AND VERIFY CONTROLLED PROCEDURE
COPY USING CURATOR
APPLICANT
EXAMINER
JPMRADMIN A.l.b
Page 2 of 8
REGION ll
INITIAL LICENSE EXAMINATION
ADMINISTRATIVE JOB PERFORMANCE MEASURE
Task: OBTAIN AND VERIFY CONTROLLED PROCEDURE COPY USING CURATOR
Alternate Path: NIA
Facilitv JBM #:
New
KIA Ratinds):
2.1.21
[3.2/3.2]
Task Standard:
References: SPP-2.3 "Document Control" Rev. 5 Section 3.1 1 and 3.12.
Task Number:: AUO-119-SSP-2.55-004
APPLICABLE FOR: AUOIROISRO
10CFR55.45:
Validation Time:
min. Time Critical: No
Verify for use a controlled procedure copy using CURATOR.
s-_s--_ss---------------------------------_------------------------------
.........................................................................
Applicant:
Time Start:
NAME
Time Finish:
Performance Ratinn: SAT __ UNSAT
~
Performance Time -
COMMENTS
JPMRADMIN A.1.b
Page 3 of 8
ToolslEquipnaenffPrscedures Needed:
Access to computer that has Curator (FYI) that can produce hard copies of documents.
NQTE: START THIS JPM AT A LOCATION WHERE PERFORMER HAS ACCESS
TO COMPUTER THAT HAS CURATOR ACCESS TO WBN. (Main Control
Room, TIC or Shift Clerk's Office, Tagging Office, Classroom).
NOTE TO EVALUATOR: If curator (FYI) program is presently open or minimized, have
the performer exit the program before assigning the task. At the completion of the task,
have the performer exit curator (FYI) program.
READ TO OPERATOR
DIRECTION TO TRAINEE:
I will explain the initial conditions, and state the admini:
stive task to be
performed. I will provide initiating cues and reports on other actions when
directed by you. Ensure you indicate to me when you understand your assigned
task. To indicate that YOU have completed your assigned task return the handout
sheet I provided you.
INITIAL CONDITIONS:
The Unit is at 100% rated thermal power.
SOl-65.02 "Emergency Gas Treatment System" is scheduled lo be performed later in
the current shift.
You are the CRO.
INITIATING CUES:
The Unit Supervisor has directed you to obtain a copy of Sol-65.02 from
CURATOR.
Inform the Unit Supervisor when you have obtained this copy.
JPMRADMIN A.1.b
Page 4 of 8
START TIME:
STEP 1:
STANDARD:
Locate a computer that has access to CURATOR.
Performer locates computer that has access to CURATOR
COMMENTS:
STEP 2:
Open CURATOR software program and access W E " Curator
files.
STANDARD: Performer selects the "FYS" icon and opens program, selects
WBNFYI Prod and enters OK. Performer enters Login ID end
password.
NOTE TO EVALUATOR: Login ID can also be LOOKUP or GUEST,
Password can also be LOOKUP or GUEST.
COMMENTS:
__ SAT
UNSAT
I
-
UNSAT
- Italicized Cues Are To Be Used only If JPhi Performance Is Being Simulated.
JPMRADMIN A.1.b
Page 5 of 8
STEP 3:
Select procedure general from Search Class List to obtain
Search Screen.
STANDARD: Performer Selects PROCEDURE GENERAL from the search
class list by selecting it (Le., highlighting it) with mouse, then
either double click mouse or use forward arrow at top of file.
COMMENTS:
STEP 4:
Enter procedure number into search screen in the Procedure
Number field.
STANDARD: Performer enters Sol-65.02 into procedure number field of the
search screen and then depresses enter key or clicks on
forward arrow. Performer may enter SO1 into the procedure
type field and select advance! then scroll until procedure found.
Performer may enter a combination of letters into the
procedure title field (Le., CONTAIN EMERGENCY or GAS
etc.).
COMMENTS:
-
UNSAT
-
__ UNSAT
- /falicked Cues Are To Be Used Only If JPM Performance Is Being Simukted.
STEP 5:
Selects procedure 501-65.02 from the document list and opens
document.
STANDARD: Performer advances to next step Folder Screen and selects
SOl-65.02 and advances to document screen and then
advances to open document.
NOTE TO EVALUATOR: Document will open in the appropriate format
COMMENTS:
for viewing. (WORD or IMAGENATION).
STEP 6:
Print a copy of Sol-65.02, retrieve copy from printer.
STANDARD: Performer simulates printing a copy of Sol-65.02.
EVALUATOR CUE: Simulate what you would do to print the document.
NOTE TO EVALUATOR: Do not allow print of document.
COMMENTS:
JPMRADMIN A.1.b
Page 6 of 8
-
-
UNS T
-
-
UNSAT
- italicized Cues Are To Be Used Only if JPM Performance Is Being Simulated.
JPMRADMIN A.1.b
Page 7 of 8
STEP 7:
Inform Unit Supervisor that a copy of Sol-65.02 has been
obtained from CURATOR.
STANDARD: Performer Informs Unit Supervisor that a copy of Sol-65.02
has been obtained from CURATOR.
- CUE:
Acknowledge report as Unit Supervisor using repeat
back.
- CUE:
Have applicant close all windows opened and exit from
curator.
COMMENTS:
END OF TASK
TIME STOP:
-
-
UMSAT
- Italicized Cues Are To Be Used Only If JPM Performance Is Being Simulated.
APPLICANT CUE S#ET
(PO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)
DIRECTION TO TRAINEE:
I will explain the initial conditions, and state the administrative task to be
performed. I will provide initiating cues and reports on other actions when
directed by you. Ensure you indicate to me when you understand your assigned
task. To indicate that you have completed your assigned task return the handout
sheet I provided you.
INITIAL CONDITIONS:
The Unit is at 100% rated thermal power.
Sol-65.02 "Emergency Gas Treatment System" is scheduled to be performed later in
the current shift.
You are the CRO.
INITIATING CUES:
e
The Unit Supervisor has directed you to obtain a copy of Sol-65.02 from
CURATOR.
e
Inform the Unit Supervisor when you have obtained this copy.
JPMRADMIN A.2
Page 1 of 13
REGION II
INITIAL LICENSE EXAMINATION
ADMINISTRATIVE JOB PERFORMANCE MEASURE
A.2 JPMRADMIN
CALCULATE QPTR USING I-SI-0-21
APPLICANT
EXAMINER
JPMRADMIN A.2
Page2of13
REGION I1
INITIAL LICENSE EXAMINATION
ADMINISTRATWE JOB PERFORMANCE MEASURE
Task: CALCULATE QPTR USING 1-SI-0-21
Alternate Path:
Facility JPM #
3-QT-JPMADA.2-1
KIA RatincW:
2.1.12
[2.9/4.0]
Task Standard:
Quadrant Power Tilt Ratio has been determined per I-SI-0-21 Section 6.7 and
Attachment I. Acceptance criteria are determined to be NOT met due for N-42
Upper Detector and N-44 Upper Detector.
Preferred Evaluation Location:
Preferred Evaluation Method:
Simulator
In-Plant
~
Perform
X
Simulate -
References: 1-SI-0-21 "Excore QPTR & Axial Flux Difference" Rev. 13; Nuclear Operating
Book (NOB) A-2 Sheet 1 Rev 60, A-2 Sheet 2-4 Rev 59.
Task Number:: RO-092-SI-2-001
APLICABLE FOR: ROISRQ
10CFR55.45:
Validation Time:
13 min. Time Critical: No
-__---------_-------___s_________s_____s-----------------------------------
s--s---------s-----____-------------------------------------------------------
Applicant:
Time Start
NAME
Time Finish:
Performance Ratinn: SAT -
UNSAT __
Performance Time -
COMMENTS
Tools/EauicmenUProcedure% Needed:
Applicant Data Sheet
Latest revision of 1-SI-0-21
Latest revision of NOB Sheets A-2 (all four PR detector channels)
Calculator
JPMRADMIN A.2
Page 3 of 13
NOTE:
START THIS JPM AT A LOCATION WHERE PERFORMER HAS ACCESS
TO PROCEDURES (Simulator, Main Control Room, TIC, etc.).
NOTE TO EVALUATOR: Hand cut the Applicant Data Sheet along with the Applicants
Cue Sheet.
READ TO OPERATOR
DRECTIQN TO TRAINEE:
I wili explain the initial conditions, and state the administrative task to be
performed. I will provide initiating cues and reports on other actions when
directed by you. Ensure you indicate to me when you understand your assigned
task. To indicate that you have completed your assigned task return the handout
sheet I provided you.
lNlTlAL CONDITIONS:
The unit is operating at 1Q0% rated thermal power
AFD Monitor Alarm and QPTR alarms are out of service due to card problem in the
annunciator system.
1-SI-0-21 Excore QPTR &Axial Flux Difference SI is required to be performed every
12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> since both QPTR alarms are inoperabte.
Plant computer is not available for performing this SI.
You are a support CRO.
INlPlATlNG CUES:
Given the data that was just obtained from each power range channel upper and
lower detector currents, the Unit Supervisor directs you to perform Section 6.1
Excore QPTR Determination of 1-Si-(8-21. M&BE wiil NOT be utilized for data
measurements.
rn
Report the results to the Unit Supervisor when Attachment 1 and Section 6.1 have
been completed.
START TIME:
STEP 1:
Obtain a copy of the instruction.
STANDARD: A copy of I-SI-0-21 has been obtained.
EXAMINERS CUE: After the performer identified correct instruction,
the evaluator can provide a copy of the
instruction.
COMMENTS:
NOTE TO EVALUATOR: The following steps are from Section 6.1 of
1-SI-0-21
NOTE 1 Obtaining QPTR calculated values from the Process
Computer is the preferred method to check that the QBTR is
within Technical Specification limits. QPTR values are
obtained from Process Computer calculated computer
points for upper and lower radial flux tilt. These points are
available on the Tilting Factors disptay. The report may
be printed with turn on code TFREP.
NOTE 2 Up to one inoperable excore channel can be marked NIA if
THERMAL BOWER is c 75% RTP.
STEP 2: [Step I]
IF the process Computer is available, THEN PRINT the
Tilting Factors Report AND/OR PERFORM the QPTR
calculations using Attachment 1.
STANDARD: Performer goes to attachment I and commences
performance of attachment 1.
COMMENTS:
JPMRADMIN A.2
Page 4 of 13
~
-
UNSAT
-
__ UNSAT
- Wicked Cues Are Tu Be Used only If JPM Performance Is Being Simu!aated.
JPMRADMIN A.2
Page 5 of 13
lOTE TO EVALUATOR: The following steps are from Attachment 1 of
1 -SI-Q-21
IOTE 1 Determining detector currents by measuring the voltage
across the detectors meter test points, using DVM, is the
IQTE 2
IQTE 3
most accurate method for measiring QPTR and for
determining the validity of a QPTR alarm.
Using detector current meter readings is another method to
quickly check that QPTR Is within limits. These meters are
not as accurate as the DVM readings and may produce
unacceptable results because: $)the meters on the 6
drawer may be scaled too high or (2) the meter may be
unstable due to drift or noise. When unacceptable results
are obtained OVM readings should be obtained, otherwise,
Step [I]
and [2] may be marked NIA if DVM not used.
Up to one inoperable excore channel can be marked NIA if
THERMAL P ~ W E R
is e 75% RTP.
- TEP 3
- [Step I] RECORD BVM information:
A.
B.
Cal Due Date:
iBANDARB: Performer determine step in N/A based on initial conditions
for task performance and proceeds to the next step.
- OMMENTS:
iTEP 4: [Step 21 ENSURE require M&PE is within its current calibration.
- $ANDARB
- Performer determines step is N/A based on initial conditions
for task performance and proceeds to the next step.
- QMMENTS:
~
-
UNSAT
-
-
UNSAT
- Italicized Cues Are To Be Used Only I f JBM Performance Is Being Simu%ated
JPMRADMIN A 2
Page 6 of 13
NOTE 1 The following determination may be made by measuring the
voltage across the 1000 ohm precision resistor in N E power
range drawer B. When using this method the Ohms Law
conversion from a millivolt measurement to a microamp
measurement only requires changing the unit designator (eg.,
280 millivolts converts to 280 microamps.
NOTE 2 Detector A is the TOP or UPPER Detector and Detector 13 is the
BOTTOM or LOWER detector on the NIS drawer El.
CAUTION
An inadvetent reactor trip may be prevented by ensuring
that no power range neutron high flux rate or power
range high flux channek are in the tripped condition
prior to taking EACH measurement in the NIS Power
Range Drawer 8.
STEP 4: [Step 31 DETERMINE the microamps for each upper and lower
excore detector on each NIS power range drawer B,
AND RECORD below:
STANDARD: Performer obtains the detector current microamp readings
from the handout given during task assignment and enters
the appropriate data into Attachment 1 step 3.
NOTE TO EVALUATOR: Values above in ( ) are detector currents from
handout.
COMMENTS:
-
UNSAT
- italicized Cues Are To Be Used Only I f JPM Performance Is Being Simulated.
JPMRADMIN A 2
Page 7 of 13
NOTE: Rt and R b (detector calibration data) changes periodically
throughout the cycle. Current valu& arein NOB SheetA-2,
NIS Calibration Data.
STEP 5: [Step 41 OBTAIN and RECORD current values of Rt and Rb
(voltsimicroamps).
STANDARD: Performer obtains the detector current values from NOB
Sheets A-2 for the respective NIS Power Range Detectors
and records them in appropriate blocks on Attachment I
Step 4.
NOTE TO EVALUATOR: Values above in ( ) are detector currents from
respective NQB Sheets A-2.
COMMENTS:
-
-
UNSAT
- !talicized Cues Are To Be Used Oniy if SPM Performance Is Being Simukated.
JPMRADMIN A.2
Page 8 of I 3
NOTE Reactor Engineering has developed a spreadsheet to ease the
calculations in this attachment. It is located on
\\\\KnxwbngfpG\\Voll \\RXEapps\\RXE files\\SI-0-21 .xIx. The test
director is responsible to verify that the formulas used in the
spreadsheet are correct.
STEP 6: [Step 51 CALCULATE calibrated output voltages by multiplying
the uncalibrated detector output currents by Rt or Rb
(as applicable).
A. Vt=ltxRt
6. Vb=ibXRb
...... -.
. __. ..
......
.
...i
LOWER DETKC'IOH
..... -.
........
T
'
T
P
E
R
DElECTOR
STANDARD: Performer calculates the calibrated output voltages [Step 31
by multiplying the respective detector's current reading
times resistance values [step 41 and records the results in
appropriate blocks on Attachment 1 Step 5.
COMMENTS:
-
I
UNSAP
- Italicized Cues Are To Be Used Only If JBM Performance Is Being Simulated.
JPMRADMIN A.2
Page 9 of 13
STEP 7: [Step S] CALCULATE average calibrated output voltage for the
upper and lower detectors.
UPPER vt
LOWER vb
AVERAGE
(14.317+16.045+14.28+16
(15.053+19.293+14.669+1
.287)/4 = 15.232
5.479)/4 = 15.623
STANDARD: Performer calculates the average output voltages for the
upper detector by adding the respective upper detector's
calibrated output voltage readings [from Step 51 and
dividing the result by the number of channels in service.
This process is repeated for the lower detector using the
lower detector calibrated voltages. The results recorded in
appropriate blocks on Attachment 1 Step 6.
COMMENTS:
- Etalicized Cues Are To Be Used Only If JBM Performance Is Being SirnuIated.
JPMRABMIN A.2
Page 10 of 13
STEP 8: [Step 71 CALCULATE QPTR values by dividing each detectors
(upper or lower) Calibration Output Voltage by the
average (upper or lower) Calibrated Output Voltage.
A. QPTRt = Vt + Avg Vt
B. QP-i-Rb = v b X Avg vb
STANBARB: Performer calculates QPTR values by dividing the
respective Calibrated Output Voltage [from step 51 by the
Average Calibrated Output Voltage for each NIS channel
detector [from step 61. The results recorded in
appropriate blocks on Attachment 1. Performer returns to
Section 6.1 Step 7.
COMMENTS:
NOTE TO EVALUATOR The following steps are from Section 6.1 of
I-si-0-21.
STEP 9: [Step 21 REVIEW the Upper (A) and Lower (B) QPTR values.
STANDARD: Performer reviews QPTR values from Attachment 1 Step 7.
COMMENTS:
-
_. UNSAP
§AT
-
UNSAP
- /talicized Cues Are To Be Used Only If JPM Performance Is Being Simulated.
STEP 20: [Step 31
CHECK (4)
Acceptance Criteria.
ACCEPTANCE CRITERIA: All operable exeore
channels (upper (A) and lower(E3)) indicate a QPTR 2
1.02.
n YES NO
STANDARD: Performer determines that N-42 Upper Detector and N-44A
Upper Detector exceed 1 .Q2
QPTR. Performer then checks
NO statement.
COMMENTS:
STEP I 1 :
Inform the Unit Supervisor that Attachment 'i and Section
6.1 of 1-SI-0-21 has been completed and the resutts of the
QPTR.
STANDARD: Performer inform the Unit Supervisor of the completion of
Attachment 1 and Section 6.1 of I-SI-0-21 and reports that
acceptance criteria have not been satisfied. QPTR for N-42
Lower Detector is 1.047 and for N-44 Upper detector is
1.079 which exceed QPTR limit of 1.02.
EXAMINER'S CUE: Acknowledge report as Unit Supervisor, then
state We wi!l stop here.
COMMENTS:
END OF TASK
TlME STOP:
JPMRADMIN A.2
Page 11 of 13
-
UNSAT
-
-
UNSAT
- /tallcized Cues Are To Be Used OR@ If JPM Performance Is Being Simulated.
APPLICANT CUE SHET
(TO BE RETURNED TO EXAMlNER UPON COMPLESlON OF TASK)
DIRECTION TO TRAINEE:
I will explain the initial conditions, and state the administrative task to be
performed. I will provide initiating cues and reports on other actions when
directed by you. Ensure you indicate to me when you understand your assigned
task. To indicate that you have completed your assigned task return the handout
sheet I provided you.
INlTlAL CONDITIONS:
The unit is operating at 100% rated thermal power
AFD Monitor Alarm and QPTR alarms are out of sewice due to card problem in the
annunciator system.
1-SI-0-21 Excore QPTR & Axial Flux Difference SI is required to be performed every
12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> since both QPTR alarms are inoperable.
Plant computer is not available for performing this SI
You are a support CRO.
INlTlATlNG CUES:
e
Given the data that was just obtained from each power range channel upper and
lower detector currents, the Unit Supervisor directs you to perform Section 6.2
Excore QPTR Determination of 141-0-21. M&TE will NOT be utilized for data
measurements.
e Report the results to the Unit Supervisor when Attachment 1 and Section 6.1 have
been completed.
APPLICANT DATA SHEET
(TO BE RETURNED TQ EXAMINER UPON COMPLETION OF TASK)
The foliowing microampere readings were taken from the Power Range
NCS detectors:
I b Detector Current
N-42A
I
368
386
I
N-438
I
369
385
I
I
N-448
I
371
386
I
JPMRADMIN A.3
Page 1 of 6
REGION
I NlTlAL LICENSE EXAM1 NATION
ADMINISTRATIVE JOB PERFORMANCE MEASURE
A.3 JPMRADMIN
Evaluate RADCON Suwey Map to determine posting
requirements
APPLICANT
EXAMINER
JPMRADMIN A.3
Page 2 of 6
REGION II
INITIAL LICENSE EXAMINATION
ADMINISTRATIVE JOB PERFORMANCE MEASURE
Task: Evaluate RADCON Survey Map to determine posting requirements
Alternate Path: N/A
Facilitv JPM #:
WA Ratinals):
2.3.1
[2.6/3.0]
Task Standard:
Candidate determines appropriate radiological posting requirements associated
with the attached RABCON survey map.
Preferred Evaluation Location:
Simulator 2
In-Plant __
Preferred Evaluation Method:
Perform
X
Simulate __
COMMENTS
ToolslEcruiDmenffProcedures Needed:
JPMRADMIN A.3
Page 3 of 6
BADCON survey map
Latest revision of SPP-5.1, 'Radiological Controls"
NOTE: START THIS JPM AT A LOCATION WHERE PERFORMER HAS ACCESS
TO PROCEDURES (Simulator, Main Control Room, TIC, etc.).
NOTE TO EVALUATOR: Hand out the Survey Map along with the Applicant's Cue Sheet.
READ TO OPERATOR
DIRECTION TO TRAINEE:
I will explain the initial conditions, and state the administrative task to be
performed. I will provide initiating cues and reports on other actions when
directed by you. Ensure you indicate to me when you understand your assigned
task. To indicate that you have completed your assigned task return the handout
sheet I provided you.
INITIAL CONDITIONS:
Plant is operating normally at power.
You are an NAUQ on shift.
INITIATING CUES:
Evaluate the provided RADCON suwey map and determine the appropriate
radiological posting requirements for this room.
Report the results to the Unit Supervisor.
JPMRADMIN A 3
Page 4 of 6
START TIME:
STEP I:
Candidate reviews materials given and may determines
references needed.
STANDARD: Candidate becomes familiar with materials. May refer to
SPP-5. T Radiological Controls.
COMMENTS:
STEP 2: Evaluation as Radiation Areas.
STANDARD: Candidate should determine the general area readings near
the bottom of the map (I00 mrem) the candidate should
identify the room as a High Radiation Area. (Candidate
may specify that the entire room is a Radiation Area and
the area where general area readings were 2 100 mrem
would be specifically posted as a High Radiation Area).
COMMENTS:
___ SAT
-
UMSAT
I
__ UNSAT
Vfalicized Cues Are To Be Used On/y I f JPM Performance Is Being Sirnuhied
STEP 3: Evaluation as Contaminated Area.
STANDARD: Candidate should also determine that the area where
smears 5, 6, 7, 8, 9, I O , 1 I,
12, and 13 were taken would
be posted as a Contaminated Area. These smears
indicated removable contamination > 1000 clprnllO0 cm2.
COMMENTS:
STEP 4: Results of the evaluation are reported to the Unit Supervisor.
STANDARD: Candidate reports results of the previous two steps.
EXAMINER'S CUE: Acknowledge report. as Unit Supervisor, then
state We will stop here.
CQMMENTS:
END OF TASK
TIME STOP:
JPMRADMIN A.3
Page 5 of 6
__ SAT
-
-
UNSAT
- Italicized Cues Are To Be Used only If JPM Performance Is Being Simulated.
APPLICANT CUE SHEET
(TO BE RETURNED SO EXAMINER UPON COMPLETION OF TASK)
DlRECTlON TO TRAINEE.:
I will explain the initial conditions, and state the administrative task to be
performed. I will provide initiating cues and reports on other actions when
directed by you. Ensure you indicate to me when you understand your assigned
task. To indicate that you have completed your assigned task return the handout
sheet I provided you.
INITIAL CONDITIONS:
Plant is operating normally at power.
You are an NAUQ on shift.
iNlTlATlNG CUES:
Evaluate the provided RADCON survey map and determine the appropriate
radiological posting requirements for this room.
Report the results to the Unit Supervisor.
--_
/Survey # 042804-1
[Datflirne: 4/28/2004 14%
~-
WBTC Mock-up
-
JPMRADMIN A.4 80
Page 1 of 10
REGION II
INITIAL LICENSE EXAMINATION
ADMINISTRATIVE JOB PERFORMANCE MEASURE
A.4.RO JPMRADMIN
RESPOND TO A MEDICAL EMERGENCY IN
ACCORDANCE WITH EPIP-10
APPLICANT
EXAMINER
JPMRADMIN 8.4 RQ
Page 2 of 'IO
REGION II
INITIAL LICENSE EXAMINATION
ADMINISTRATIVE JOB PERFORMANCE MEASURE
Task: Respond To A Medical Emergency
Alternate Path:
N/A
Facility JPM #
3-QT-JPMADA.4-1
KIA Ratlnnls):
2.4.39
[3.3/3.1]
Task Standard:
Performer performs actions of Appendix A of PIP-IO, "Medical Emergency
Response".
Preferred Evaluation Location:
Preferred Evaluation Method:
Simulator
In-Plant ___
Perform
X
Simulate
~
References: EPIP-IO, "Medical Emergency Response", Rev. 18.
Task Number:
RO-100-501-100-011
APPLICABLE FOR: RO/SRQ
Examiner:
NAME
I
§IGNATURE
DATE
COMMENTS
JPMRADMIN A.4 RO
Page 3 Qf 10
SIMULATOR OPERATOR INSTRUCTIONS:
This JPM may be performed either on the simulator or in another location. If performed
on the simulator refer to the fullowing.
1. Initialize to any IC.
2. Acknowiedge all alams.
3.
Freeze sirnulator for duration of task performance.
4. NOTE: This JPM may be performed using a console booth instructor who acts
as personnel outside the main control room. Cues may be made by him as
indicated by the JPM.
SlMULATQR OPERATOR INSTRUCTIONS:
When directed by the evaluator, place phone call to the Horseshoe to initiate the
medical emergency:
Call the Horseshoe and state the following:
I want to report a medical emergency.
ToolslE~ui~menffPfocedures
Needed:
Latest revision of EPIP-10
JPMRABIISIN A.4 RO
Page 4 of 10
NOTE START THIS JPM AT A LOCATION WHERE PERFORMER HAS ACCESS
TO PROCEDURES (Simulator, Main Control Room, TIC or provide
performer wlth procedure).
READ TO OPERATOR
DIRECTION TO TRAINEE:
I will explain the initial conditions, and state the administrative task to be
performed. I will provide initiating cues and reports on other actions when
directed by you. Ensure you indicate to me when you understand your assigned
task. To indicate that you have completed your assigned task return the handout
sheet I provided you.
INITIAL CONDITIONS:
You are the Control Room Operator (CRO)
on shift.
You have received a telephone call reporting an onsite medical emergency.
INITIATING CUES:
Respond to the medical emergency in accordance with PIP-IO.
JPMRADMIN A.4 RO
Page 5 of 10
START TIME:
STEP 1:
Obtain a copy of the instruction.
STANDARD: A copy of EPIP-IO has been obtained.
EXAMINERS CUE: After the performer locates and obtains correct
instruction, the evaluator can provide a copy of the
instruction.
COMMENTS:
NOTE TO EVALUATOR: The following steps are from EPIP-10, Appendix
A.
Control room personnel will USE the following checklist in their RESPONSE to
an onsite medical emergency.
STEP 2: [Step A]
Obtain NAME of caller.
STANDARD: CRO requests name of caller and records on Appendix A.
CUE: State to the performer that your name is John Doe.
COMMENTS:
-
-
UNSAT
-
-
UNSAT
JPMRADMIN A.4 RO
Page 6 of 10
STEP 3: [Step B] LOCATION (Bldg., Elev., Column).
STANDARD: Performer requests the location of the caller and records on
Appendix A.
CUE: State to the performer that you are just south of the
station air compressors on elevation 708 in the
Turbine Building.
COMMENTS:
STEP 4: [Step C] Type of Medical Emergency.
STANDARD: Performer requests the type of Medical Emergency and
records on Appendix A.
CUE: State to the performer that you found a male victim lying
on the floor unconscious but has heartbeat and is
breathing.
COMMENTS:
STEP 5: [Step D] Number of Personnel Involved
STANDARD: Performer requests how many people involved and records on
Appendix A.
CUE: State to the performer: no other individuals are involved.
COMMENTS:
CRITICAL
STEP
-
-
UNSAT
CRITICAL
STEP
-
§AT
I_
UNSAT
-
UNSAT
JPMRADMIN A.4 RO
Page 7 of 10
STEP 6:. [Step E] Immediate Area Hazards (Radiological, Safety).
STANDARD: Requests if immediate hazards exist and records on
Appendix A.
CUE: State to the performer: no hazards exist in the area.
COMMENTS:
STEP 7: [Step F] Telephone number of Caller.
STANDARD: Request the telephone number of the caller and records on
Appendix A.
CUE: State to the performer that the phone number of the phone
you are calling from is 5555.
COMMENTS:
STEP 8: [Step G] ALERT and DISPATCH MERT PERSONNEL
STANDARD: Performer alerts and dispatches MER1 personnel.
CUE: As MERT personnel, acknowledge performers
communication.
COMMENTS:
CRITICAL
STEP
-
-
UNSAT
-
-
UMSAT
CRITICAL
STEP
-
-
UNSAT
JPMRABMIN A.4 RO
Page 8 of 10
STEP 9: [Step HI Make the foliowing plant announcement with public
address:
ATTENTION ALL SITE PERSONNL.
ATTENTION ALL SITE PERSONNEL.
A MEDICAL emergency has been reported. The MRT is
to ACTIVATE and RESPOND to the following LOCATION:
,I
STANDARD: Performer makes public address announcement and has
MERT respond to Turbine Building elevation 708, just south of
the station air compressors.
EXAMINIZRS CUE: If NOT being performed on the simulator, do NOT
allow performer to actually perform this
announcement. Ensure it is simulated.
COMMENTS:
STEP I O : [Step I]
CONFIRM that the Shift Manager (SM) has been notified.
STANDARD: Performer ensures the SM has been notified. (may make
phone call or announce to the control crew that a medical
emergency is in progress.)
- CUE:
Acknowledge report as Shift Manager.
COMMENTS:
-
-
UNSAT
CRITICAL
STEP
-
-
UNSAT
JPMRADMIN A.4 80
Page 9 of 10
STEP 1 'i : [Step S] CONFIRM that the Fire Protection Section Duty Shift
Supervisor (Fire Brigade Leader) was notified by:
Radio or
Telephone (extension #331 I
or #3355) or
Pocket Pager #40566
STANDARD: Performer ensures the Fire Protection Section Duty ShiR
Supervisor was notified by Radio, Telephone, or Pocket Pager.
EXAMINER'S CUE: Do NOT allow performer to actually perform this
notification. Ensure it is simulated.
CUE: Acknowledge report as Fire Protection Section Duty Shift
Supervisor.
COMMENTS:
STEP 12: [Step MI CONFIRM1600RDINATE MERT response (via radio or
phone) until Incident Commander assumes control.
STANDARD: Performer confirmsicoordinate the MERT response until the
Incident Commander assumes control.
CUE: As Incident Commander, notify the performer that you
have assumed control of the emergency. We will stop
here.
COMMENTS:
END OF TASK
TIME STOP:
-
-
UNSAT
CRiTiCAL
STEP
-
-
UNSAT
APPLICANT CUE SHEET
(TO BE RETURNED TO XAMINER UPON COMPLETION OF TASK)
DIRECTION TO TRAINEE:
I will explain the initial conditions, and state the administrative task to be
performed. I will provide initiating cues and reports on other actions when
directed by you. Ensure you indicate to me when you understand your assigned
task. To indicate that you have completed your assigned task return the handout
sheet I provided you.
INITIAL CONDITIONS:
You are the Control Room Operator (CKO) on shift
You have received a teiephone call reporting an onsite medical emergency.
INITIATING CUES:
Respond to the medical emergency in accordance with PIP-10.
f
k
APPENDIX A
CONTROL ROOM OPERATOR MEDICAL RESPONSE CHECKLIST
onsite medicai emergency.
A. Obtain NAME of caller
0
B. LOCATION (Bldg., Elev., Coiumn)
0
C. Type of Medical Emergency
0
D. Number of Personnel Involved
0
E. Immediate Area Hazards (Radiological, Safety)
Bs
0
0
F. Telephone Number of Caller
H. Make the following plant announcement with public address:
G. ALERT and DISPATCH MERT PERSONNEL
"ATTENTION ALL SITE PERSONNEL."
"ATTENTION ALL SITE PERSONNEL."
"A MEDICAL emergency has been reported. The MERT is to
ACTIVATE and RESPOND to the following LOCATION: ..
1. CONFIRM that the Shift Manager (SM)
has been notified.
J. CONFlRM that the Fire Protection,Section Duty Shift
I7
Supewisw (Fire Brigade Leader) was notified by:
Telephone (extension #33t 1 or #3355) and Pocket Pager #40%6
K. CONFlRMlCOORDlNATE MERT response (via radio or phone)
0
until Incident Commander assumes control.
PAGE 8 of 24
REVISION I 8
REGION II
JPMRADMIN A.4 SRO Scenario 1
Page 1 of 20
INITIAL LICENSE EXAMINATION
Admin A.4 /Scenario 1
Classify the Event per the REP (SGTR with Ruptured SG
Faulted Inside Containment)
APPLICANT
EXAMINER
JPMRADMIN 8.4 SRO Scenario 1
Page 2 of 20
EVALUATION SHEET
~ Task: Classify the Event Per The RP (SGTR With Ruptured SG Faulted Inside Containment)
Alternate Path: NIA
Facilitv SPM #:
New
KIA Ratinak):
009 '32.04 [3.8/4.0]
009 EK3.06 [3.9/4.01 009 EA2LM [3.8/4.3]
2.4.38 [2.2/4.0]
009 EA2.33 [3.3/3.%]
009 EK3.10 13.413.61
2.4.30 [2.2/3.6]
2.1.14 [2.4/3.3]
Task Standard:
The event is classified as an ALERT based on EAL 1.2.3- "RCS Barrier. SGTR that results in a
safety injection actuation OR entry into E-3." Notifications are made per EPIP-3.
Preferred Evaluation Location:
Simulator
X
In-Plant -
Perform
X
Simulate
~
References: PIP-1 "Emergency Pian Classification Flowpath", Rev. 21; EPIP-3 ALERT", Rev. 26;
Preferred Evaluation Method:
EPIP-8 "Personnel Accountability and Evacuation". Rev 20.
Task Number: SRO-113-EPIP-001
10CFR55.45: 11, 12, 13
APPLlCA5LE FOR: SRO
Applicant:
Time Start:
NAME
Time Finish:
Performance Ratinq: SAT __ UNSAT __
Performance Time __
Examiner:
/
NAME
SIGNATURE
BATE
COMMENTS
JPMRADMIN A.4 SRO Scenario 1
Page 3 of 20
SIMULATOR OPERATOR INSTRUCTIONS:
1. Phis JPM will commence from the point where simulator is frozen at the end of simulator
exam scenario 1
SIMULATOR OPERATOR INSTRUCTIONS:
1. Obtain copy of EPP-3 to facilitate role plays for contacts made by the performer.
2. Performer must use NRC ring down phone.
REQUIRED MATERIALS: EQIP-2 and EPIP-3
SAFETY CONSIDERATIONS: None
JPMRADMIN A.4 SRO Scenario 1
Page 4 of 20
ToolslEquiprnenffProcedures Needed:
Ensure clean copy of EPIP-3 and PIP-8 in all copies of Emergency instructions on the
Simulator Floor and in the file drawer of Unit Supervisors desk.
READ TO OPEFWTOR
DIRECTION TO TRAINEE:
I will expiain the initial conditions, and state the task to be performed. All control
room steps shall be performed for this JPM, including any required
communications. I will provide initiating cues and reports on other actions when
directed by you. Ensure you indicate to me when you understand your assigned
task. To indicate that you have completed your assigned task return the handout
sheet I provided you.
INITIAL CONDITIONS:
Simulator represents the current plant conditions.
Sirnulator operation is frozen
INITIATING CUES:
Using the current conditions, make the initial classification of the event per the
REP and make the required notifications.
Portions of this JPM are time critical.
JPMRADMIN 8.4 SRO Scenario 1
Page 5 of 20
START TIME:
STEP 1:
Refers to EPIP-I to determine level of event
STANDARD: Performer refers to PIP-I and declares an ALERT based
on EAL 1.2.3 RCS Barrier, SGTR that results in a safety
injection initiation OR entry into E-3. This must be
completed within 16 minutes of task assignment.
This step is critical to ensure proper activation of TVA
resources for event In progress.
COMMENTS: RECORD time that declaration was made:
STEP 2:
Implements EPIP-3, ALERT
STANDARD: EPIP-3, ALERT, is implemented.
COMMENTS:
CRITICAL
STEP
-
-
UNSAT
I
-
UNSAT
JPMRADMIN A.4 SRO Scenario 1
Page 6 of 20
NOTE 1
IF ongoing onsite Security events may present risk to the
emergency responders, THEN ... CONSULT with Security to
determine if site access is dangerous to the life and health of
emergency responders.
IF ongoing events makes site access dangerous to the life and
health of emergency responders WHEN activating EPS ...
SELECT STAGING AREA button on the terminal INSTEAD of
the EMERGENCY button. Offsite personnel will be directed to
the Training Center CR 19 (INC). Responders presently within
the Protected Area will monitor Plant Announcements and
report to the TCS or OSC as conditions permit.
NOTE 2
STEP 3:
[STEP I]
DIRECT Shift Personnel to activate the
Emergency Paging System (EPS) to staff the TSC and
Operations Support Center (OSC). Shift Personnel should
confirm activation and provide the 20 minute printed report
to the SM for review.
A
IF the EPS system fails, call the QDS, ringdown or (5-
751-1700) and have him activate the EPS.
5
IF the above methods of activating the EPS fail, Shift
Personnel must use the Radiological Emergency
Response Call Lists to staff the TSC and OSC. This
list is located in the EPS Manuai near the terminal.
STANDARD: Shift personnel are notified to activate the emergency
paging system (EPS)
to staff the TSC and Operations
Support Center (OSC) or EPS is activated in the control
room.
This step is criticai to ensure proper actiwation of TVA
resources for event in progress.
- CUE: After the shift personnel are notified, acknowledge the
request to activate the Emergency Paging System.
COMMENTS:
CRITICAL.
STEP
-
UNSAT
JPMRADMIN A.4 SRO Scenario 1
Page 7 of 20
STEP 4:
[STEP 21 lNlPiATE Appendix A, Initial Notification
Information.
STANDARD: Appendix A is accurately completed.
COMMENTS:
NOTE: ODs should be notified witkin 5 minutes after declaration of the
~
event.
STEP 5:
[STEP 31 NOTiFY the ODs direct by OD% Ringdown or No.
5-751-1900 or 5-751-2495 and PROVIDE the information
from Appendix A.
IF the ODs cannot be contacted within I 0 minutes, the
Tennessee Emergency Management Agency is to notified of
the Radiological Emergency Plan activation by calling 9-1-
800-262-3300 or 9-1-675-741 -0001 or 9-1-800-262-3400.
STANDARD: The ODS is notified and provided the information on
Appendix A. This notification must be made within 5
minutes of event declaration.
Step is critical to ensure timely staffing of CECC and
notification of the appropriate state agencies.
EVALUATOR NOTE: DO NOT allow actual call to ODs. Ensure call is
to simulator instructor
- CUE: (Booth Operator) Role play as the ODS and repeat
back the report.
COMMENTS: RECORD time that ODS was notified:
CRITICAL
STEP
-
§AT
__ UNSAT
JPMRADMIN A.4 SRO Scenario I
STEP 6:
[STEP 41 ANNOUNCE to the crew: AN ALERT is being
declared based on EAL 1.2.3,
I will
be the Site Emergency Director.
describing the event may vary.
Step is critical to alert crew to the declaration ofthe
ALERT and provide for tracking personnel.
STANDARD: The above announcement is made to the crew. Wording
CUE
COMMENTS:
After the crew is notified, acknowledge the report.
STEP 7:
[STEP 51 FAX Appendix A to the ODS. (# pre-
programmed or 5-751-8620), or TEMA at 9-1-615-242-
9635.
STANDARD: Appendix A is placed in the fax machine and transmission
simulated.
- CUE: Do NOT allow fax to be transmitted.
COMMENTS.
Page 8 of 20
CRITICAL
STEP
-
-
UNSAT
-
-
UNSAT
JPMRADMIN A.4 SRO Scenario 1
Page 9 of 20
STEP 8:
[STEP 61 ANNOUNCE to the plant: "ATTENTION ALL
SITE PERSONNEL. ATTENTION ALL SITE PERSONNEL.
AN ALERT emergency is being declared based on EAL
1.2.3 "RCS Barrier, SGPR." Staff the TSC and QSG.
(Repeat)
STANDARD: A public address announcement for Plant Emergency
Response Personnel to staff the TSC and OSC is made
over the plant paging system. Wording describing the event
may vary.
Step is critical to alert all plant personnel of the REP
declaration and instructions staffing TSC and OSC.
COMMENTS:
CAUTION If there is any possibility of a radiological release, A
severe weather condition (such as a Tornado) or
security adversary attack, HOLD assembly and
accountability actions until these conditions have been
resolved. Do not send personnel into areas of
unknown radiological conditions or security risk
without first contacting Radiological Control (RADCON)
or Security.
CRlTlCAL
STEP
__ SAT
-
UNSAT
JPMRADMIN A.4 SRO Scenario 1
Page 10 of 20
NOTE TO Evaluator: Performance Steps 9 through 17 will only be
critical if the decision was made to initiate assembly
and accountability.
If assembly & accountability is not being performed
than go to JPM STEP 18 after JPM Step 9 is completed.
STEP 9:
[STEP 71 EVALUATE piant conditions, and IF conditions
warrant, THEN INITIATE EPIP-8, Personnel Accountability
and Evacuation, Appendix D
STANDARD: Performer decides if conditions warrant initiating assembly
and accountability. If the decision is that conditions do
require assembly & accountability then the performer goes
to PIP-8 then return to EQIP-3 when directed for next step.
If the decision is that conditions do NOT require Assembly
& Accountability then performer proceeds to EQlP 3 step 8.
(Evaluation steps Page I 6 JPM Step 18)
COMMENTS:
EVALUATOR NOTE: The following steps are from EPIP-8 Appendix D.
STEP I O :
[STEP 11 The SMlSED has determined that conditions
require the activation of the assembly and accountability
siren system and process:
STANDARD: The performer determines that assembly and accountability
should be performed and continues to the next step.
COMMENTS:
-
-
UNSAT
UNSAT
JPMRADMIN 14.4 SRO Scenario 1
STEP 11 :
[STEP 21 NOTIFY Nuclearsecurity (NS)
at ext. 8464 or
8495 that:
A.
The assembly and accountability sirens will be
activated immediately. AND
B. NS should implement Appendix E.
STANDARD: The performer notifies Nuclear Security that assembly and
accountability sirens will be activated and Nuclear Security
should implement Appenix E.
This step is critical to ensure assembly card readers
are enabled.
- CUE:
(Booth Operator) Role play as the Security and repeat
back the reportlrequest.
COMMENTS:
STEP -I2
[STEP 31 NOTIFY Radiological Control (RABCON) at ext
7865 That:
A.
The assembly and accountability sirens will be
activated immediately. AND
B. RADCON should implement Appendix F.
STANDARD: The performer notifies RABCQN that assembly and
accountability sirens will be activated and Nuclear Security
should implement Appenix F.
This step is critical to ensure assembly card readers
are enabled.
- CUE:
(Booth Operator) Role play as the RADGON and repeat
back the reportlrequest.
COMMENTS:
Page 11 of 20
CRITKAL
STEP
-
-
UNSAT
CRlTICAL
STEP
-
-
UNSAT
JPMRADMiN A.4 SRO Scenario 1
STEP 13:
[STEP 41 MAKE a public address announcement similar
to: Attention all plant personnel, the site assembly and
accountability process has been initiated. All personnel
report immediately to your assigned assembly areas.
(Repeat)
STANDARD: A public address announcement for Plant Assembly &
Accountability is made over the plant paging system.
Wording of this announcement may vary.
StSP is critical to alert all plant that personnel assembly
& accountability is being conducted.
COMMENTS:
STEP 14:
[STEP 51 ACTIVATE the assembly and accountability
STANDARD: The performer pushes assembly alarm EVAC AUTO or
EVAC MANUAL push button.
This step is critical to activate assembly &
accountability alarm.
COMMENTS:
Page 12 of 20
CRITICAL
STEP
-
-
UNSAP
CRITICAL.
STEP
-
-
UNSAB
JPMRABMIN A.4 SRO Scenario 1
Page 13 of 20
STEP 15:
STANDARD:
COMMENTS:
[STEP SI WHEN the Assembly and Accountability Sirens
have completed the 3-minute cycle and silenced, THEN
MAKE a PA announcement similar to:
"Attention all plant personnel, the site assembly and
accountability process has been initiated. All personnel
report immediately to your assigned assembly areas and be
accounted for".
(Repeat)
After the sirens have silenced, a public address
announcement for Plant Assembly & Accountability is made
over the plant paging system. Wording of this
announcement may vary.
-
-
UNSAT
JPMRADMIN A.4 §BO Scenario 1
Page 14 of 20
NOTE: IF at any time during the assembly and accountability
process RADCON determines that radiatfon guidelines
for an assembly area@) have been exceeded, THEN
REQUEST NS to re-locate affected personnel to another
assembly area OR evacuate affected personnel offsite.
STEP 16:
[STEP 71 NOTIFY Central Emergency Control Center
(CECC) Director either by the direct ring-down telephone in
the TSC or at ext. 751-1614. OR
If the CECC Director can not be reached, notidy the
Operations Duty Specialist (ODS) at ext. 751-1700 that:
A.
The assembly and accountability sirens have been
activated. AND
i3. WBN EPlP-8 is currently being implemented for
assembly and accountability.
STANDARD: The CECC director or the ODS has been notified that
assembly and accountability is being conducted at Watts
Bar and that the sirens have been activated.
- CUE:
(Booth Operator) Role play as the CECC Director or
ODS and repeat back the reportlrequest.
COMMENTS:
STEP 17:
[STEP 81 REFER TO EPIP-2 through EPIP-5 for remaining
actions while Accountability is being performed.
STANDARD: The performer refers to EPIP-3, step 8 while Accountability
is being performed.
COMMENTS:
-
_- UNSAP
JPMRABMIN A.4 SRO Scenario 1
Page 15 of 20
Evaluator Note: The following steps are from EPIP-3
STEP 18:
[STEP 81 CALL FSADCON Lab (~7865)
and SAY: We are
in an ALERT, implement EPP-I4 Radiological Control
Response and CECC EPIP-9.
STANDARD: The WDCON Lab is notified to implement EPIP-14 and
CECC EPIP-9.
This step is critical to notify RADCON so proper
surveys, etc. are implemented.
(Booth Operator) Acknowledge the request to
implement EPIP-14 and CECC PIPS.
- CUE:
COMMENTS:
STEP 19:
[STEP 91 IF there are personnel injuries, IMPLEMENT
WBN EPIP-IO, Medical Emergency Response.
STANDARD: Performer determines that it is NOT necessary to
implement EPIP-10.
- CUE:
Inform the performer that there are NO personnel
injuries.
COMMENTS:
CRiTlCAL
STEP
-
-
UNSAT
-
-
UNSAK
JPMRADMIN A.4 SRO Scenario 1
Page 16 of 20
NOTE: Security and Access Control will be implemented
through PIP-31, Security and Access Control.
STEP 20:
[STEP 101 NOTIFY Duty Plant Management in
accordance with SPP-3.5, AND PROVIDE ALEKT
Notification information.
STANDARD: Duty Plant Manager is provided the Appendix A information.
This step is critical as it alerts plant management to
REP activation.
- CUE:
(Booth Operator) Role play as the Duty Plant Manager
and acknowledge the report.
COMMENTS:
STEP 21:
[STEP 111 EVALUATE the need to implement PIP-13,
Initial Dose Assessment for Radiological Emergencies, for
a dose projection if radioactivity is being released through
normal plant release paths.
STANDARD: The performer determines whether or not EPIP-13 is to be
implemented. Either decision is acceptable.
- CUE
(Booth Operator) If RADCON is notified to implement
EPlP-13, acknowledge the report.
COMMENTS:
CRlTlCAL
STEP
I
-
UNSAT
I
-
UNSAT
JPMRADMIN A.4 SRO Scenario 1
Page 17 of 20
STEP 22:
[STEP 121 RECEIVE Confirmation call from the OD§ (to
verify notification of the State of Tennessee) (MA this step,
if the state was contacted directly).
STANDARD: The performer determines whether or not ODS has notified
the State of Tennessee of REP Activation.
"*CUE:
(Booth Operator) Role play as the ODS and report that
the State of Tennessee has been Notified of REP
Activation at Watt Bar Nuclear Plant.
COMMENTS:
-
-
UNSAT
JPMRADMIN A.4 SRO Scenario 1
Page 18 of 20
NRC notifisation should be made as soon as practicable
but within one hour of ALERT declaration. Whenever
NRC requests, a qualified person must provide a
continuous update to NRC Operations Center.
EVALUATOR NOTE: DO NOT allow actual call to NRC. Ensure call is
STEP 23:
[STEP 131 NOTiFY the NRC, using designated NRC
phone (ENS), of plan activation. The following commercial
numbers are for the NRC Operations Center.
9-2-301-826-51 00 (MAIN)
9-1 -301 -951 -O550 (BACKUP)
9-1 -301 -81 6-51 51 (FAX)
STANDARD: The NRC is notified of plan activation using designated line.
This step is criticar as it alerts NRC to REP activation.
EVALUATOR NOTE: DO NOT allow actual sal! to NRC. Ensure call is
to simulator instructor.
- CUE:
(Booth Operator) Role play the NRC and acknowledge
the report.
1 COMMENTS:
CRITICAL
STEP
I
-
UNSAT
JPMRADMIN A.4 SRQ Scenario 1
Page 19 of 20
STEP 24:
[STEP 141 NOTIFY the NRC Resident Inspector by calling
1776 and PROVIDING the information on Appendix A.
STANDARD: The NRC Resident Inspector is provided Appendix A
information.
This step is critical as it alerts NRC to RP activation.
EVALUATOK NOTE: DO NOT allow actual call to NRC Resident.
Ensure call is to simulator instructor.
(Booth Operator) Role play the NRC Resident and
acknowledge the report.
- CUE:
EVALUATOR NOTE: Give the following cue to performer when the
performer completes the call to the NRC Resident
Inspector:
Role play and report that the TSC is staffed, and that
the SED will be coming to the control room $or a
turnover of SED duties. W e will stop here.
- "CUE:
COMMENTS:
END OF TASK
TIME STOP:
CRITICAL
STEP
-
§AT
-
UNSAT
APPLICANT CUE SHEET
(TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)
DIRECTION TO TRAINEE:
I will explain the initial conditions, and state the task to be performed. Ail control
room steps shall be performed for this JPM, including any required
communications. I will provide initiating cues and reports on other actions when
directed by you. Ensure you indicate to me when you understand your assigned
task. To indicate that you have completed your assigned task return the handout
sheet I provided you.
INITIAL CONDITIONS:
Simulator represents the current piant conditions.
Simuiator operation is frozen.
INITIATING CUES:
Using the current conditions, make the initial classification of the event per the
REP and make the required notifications.
Portions of this JPM are time critical.
Control Roomh-Plant Systems Outline
Form 3-301-2
Facility. Watts Bar
Exam Level (circle one-/
Date of Examination: 7/26 - 713012004
Operating Test No.:
/I
System I JPWI Title
a. JPMF?018A, Perform a Boration of RCS During ATWS per I
8,
S, A I
1
//
11
FR-S.I.
7
b. JPMROZA, Place Excess Letdown In Service per SOI-
62.81,
1 c. JPMR071A, Align SI Pumps for Hot Leg Recirculation per
ES-I .4.
! 1 g. JPMO42ATransfer RCP Board from Normal to Alternate
I
N, S, L
1
6
I/
h. JPMR044, Align of the Upper Cntmt Monitor to the Lower
H
Cntmt From the MCR.
a. JPMA024, Isolate the RCP Seal Injection and Thermal
Barrier per ECA-0.0.
b. JPMA034, Reset the TBAFW Pump (after mechanical
overspeed) per Sol-3.02
dified from bank, (N)ew, (A)Mernatts path, (C)ontroi
NUREG-1021, Draft Revision 9
-
Control Roomlln-Plant Systems Outline
Form ES-301-2
Facility: Watts Bar
Exam Level (circle one): RO I SRO(I)@
Control Room Systems (8 for RO; 7 for SRO-I; 2 or 3 for SRO-U)
Date of Examination: 7/26 - 7/30/2004
Operating Test No.:
System / JPM Title
FR-S.1.
c. JPMR0718, Align SI Pumps for Hot beg Recirculation per
3
I
I
c.
JPMl29A, Return the PRT to Normal per 501-68.01.
D, S, A
5
d
e.
h.
I
I
In-Plant Systems (3 for RO, 3 for SRO-I, 3 or 2 for SRO-U)
a
JPMA024, Isolate the RCP Seal Injection and Th
Barrier per ECA-0 0
JPMAOOIB.. Perform Local Restart of Control and Service
Air Compressors per AOI-10
b
C
- Type Codes: (D)irect from bank, (M)sdified from bank, (N)ew, (A)lternate path, (C)ontrol
room, (S)imulator, (L)ow-Power, (R)CA
_II
NLIREG-1021, Drat? Revision 9
_____
Control Roomlln-Plant Systems Outline
Form ES-381-2
Facility: Watts Bar
Date of Examination: 7/26 - 7/3012004
Exam bevel (circle one): RO
SRO(U)
Operating Test No.:
A
System / JPM Title
b. JPMR022A, Place Excess Letdown In Service per SOI-
62.01.
I
c. JPMR071A, Align SI Pumps for Hot Leg Recirculation per
11 d. JPMR075, Remove 1 RCP from Service (<P-8) per AOI-5.
~
~~
e. JPM129A, Return the PRT to Normal per SOI-68.01.
(1 g. JPM042A, Transfer RCP Board from Normal to Alternate
a. JPMA024, Isolate the RCP Seal Injection and Thermal
b. JPMA034, Reset the TDAFW Pump (after mechanical
overspeed) per Sol-3.02
6. JPMAOOIB, Perform Local Restart of Control and Service
I
Air Compressors per AOI-10.
- Type Codes: (D)irect from bank. (M)odified from bank, (N)ew, (A)iternate path, (C)ontrol
I room, (S)irnulator, &)ow-Power, (R)CA
NUREG-1021. Draft Revision 9
B.1.a ROlSRO
Page 1 of 10
REGION II
INITIAL LlCENSE EXAMINATION
B-1 .a RQlSRQ JPMROl8A
Perform Boration Of The RCS During An ATWS
Per FR-S.1
APPLICANT
EXAMINER
B.1.a RO/SRO
Page 2 of 40
REGION II
INITIAL LICENSE EXAMINATION
Task: Perform Boration Of The RCS During An ATWS Per FR-S. 1
Alternate Path:
Emergency Borate Valve 1-FCV-62-138 cannot be open from MCR requiring
use of RNO to open varve lecaily. Local Operation also fails requiring use of
alternate boration valve 1-ISV-62-929.
3-OT-JPMR01BA Rev 6
Facilitv JPM #:
K/A Ratinafs):
029-EK3.Il [4.2/4.3] 023-EAT .02 [3.6*/3.3]
2.1.20 [4.3/4.2]
2.1.32 [4.2/3.4]
029EA1.03 [3.5*/3.2]
029-EA1.05 [3.7*/3.6*]
Task Standard:
Preferred Evaluation Location:
Preferred Evaluation Method:
Simulator X In-Plant __
Perform
X
Simulate ~
References: FR-S. 1, Nuclear Power Generation/ATWS, (Rev 16)
Task Number:: RO-113-FR-S.1-001
APPLICABLE FOR: ROl§RO
1QCFR55.45: 4, 5, 6, 7, 8, 12
Validation Time:
8 min.
Time Critical: No
The RCS has been borated per FR-S. 1 Step 4.
-_---_s-------------___s__s__________s__-----------------------------------
_____-_-____-_-____-__s_______s_______s_---------------------_-------------
Applicant:
Time Start:
NAME
Time Finish:
Performance Rating: §AT __ UNSAT _s
Performance Time __
COMMENTS
B.1.a ROlSRO
Page 3 of 10
SIMULATOR OPERATOR INSTRUCTIONS:
1. Initialize to IC 153.
2.
3.
Piace Hold Order on CCP IB-B.
Insert the foilowing over ride: ior rdihs82138a close to fail 1-FCVS2-I38 to the
closed position.
3. After performer indicates understanding of the task, place simulator to RUN
4. Place simulator to RUN after performer has been briefed.
5. This JPM has been pre-shot in IC#l53. Shouid IC#153 be erased or fail to perform
as expected then use the following set-up instructions:
Initialize in IC #5Q.
Insert remote function cvrQ3 off to remove power from CCP-1 B-B.
Insert override to fail 1-FI-62-139 as is: ier zaofi62439 as is.
Insert the following over ride: ior zdihs62138a close to fail 1-FCV-62-138 io the
Insert imf rpOlc ATWS Condition.
Insert ior zdific335 close
When RX Trip Signal is activated, trip the Turbine, start XJ AFW pump, wait for
After the Reactor Coolant Pump transfer occurs, FREEZE the simulator.
Place H.0. on CCP B.
After performer indicates understanding of the task. place simulator to RUN.
SIMULATOR OPERATOR INSTRUCTIONS:
Step 10 of the JPM requires the following remote function to OPEN 1-lSV-62-929:
Pull to lock CCP ZB-B.
closed position.
PC5 to trip and dear horns and annunciators.
mrf cvrlO open for 1-ISV-62-929
B.l .a R01SR0
Page4of40
TQsls/EttUiplrrsent/Proceelures Needed:
Ensure clean copy of FR-§.I in ail copies of Functional Restoration Guidelines on the
Simulator Floor.
READ TO OPERATdR
DIRECTION TO TRAINEE:
I will explain the initial conditions, and state the task to be performed. All control
room steps shall be performed for this JPM, including any required
communications. I will provide initiating cues and reports on other actions when
directed by you. Ensure YOU indicate to me when you understand your assigned
task. To indicate that you have completed your assigned task return the handout
skeet I provided you.
INlTlAL CONDITkONS:
Unit in Mode 1 at 100% RTP
1-FI-62-139 BA TO BLENDER FLOW is OQS, being calibrated by 1Ms.
CCP I
B-B is out of sewice (hold order)
A valid Rx Trip First-Out Alarm (§/e /ow ievel) was received
No Rx Trip occurred.
E-0 was entered and transition made to FR-S.1.
The first three steps of FR-S.1 have been completed.
The OAC will monitor the Rods inserting.
You are the CRO.
iNlTlATlNG CUES:
You are to perform boration of the RCS per FR-S.1 Step 4.
You are to notify the Unit Supervisor when the borabion has been established.
E.1.a RO/SRO
Page 5 of 10
START TIME:
STEP 1:
Obtain a copy of the procedure.
STANDARD: A copy of FR-S.1 has been obtained.
COMMENTS:
-
I_ UNSAT
STEP 2:
[Step 41 INITIATE RCS boration:
a. ENSURE at least one centrifugal charging pump
RUNNING.
__ SAT
STANDARD: Charging Pump A is verified to be running by either Red light
on 1-HS-62-108A or Amps on I-El-62-108A.
_I UNSAT
COMMENTS:
STEP 3:
[STEP 4b] OPEN RWST outlet valves 1-LCV-62-135 and 'I-
LCV-62-136.
STANDARD: 1-HS-62-135A and I-HS-62-136A have been placed in the
OPEN position. Step is critical to provide RWST flow path
for boration of RCS.
EVALUATOR NOTE: Either one oftha 2 valves being opened will satisfy
this step.
COMMENTS:
CRITICAL
STEP
__ SAT
-
UNSAT
i
STEP 4:
[STEP 4cl
CLOSE VCT outlet valves 1 -bCV-62-132 and 1
LCV-62-133.
STANDARD:
1-HS-62-132A and 1-HS-62-133A have been placed in the
CLOSE position.
Step is critical isolate VCT from
operating CCP and ensure RWST boration source.
EVALUATOR NOTE: Either one sf the 2 valves being closed will satisfy
this step.
COMMENTS:
STEP 5:
[STEP 4d] OPEN BIT outtet values, 1-FCV-63-25 and 1-
FCV-63-26.
STANDARD: 1-MS-622% and 1-HS-62-26A have been placed in the
OPEN position. Step is critical increased boration flow
path to RCS.
EVALUATOR NOTE: Either one of the 2 valves being opened will
satisfy this step.
COMMENTS:
STEP 6:
[STEP 4el
CHECK BIT flow.
STANDARD: Flow is determined by use of 1-Fl-63-170
COMMENTS:
f3.Z.a ROlSRO
Page 6 of 10
CRITICAL
STEP
-
I
UNSAT
CRITICAL
STEP
-
-
UNSAT
-
-
UNSAT
B.1.a ROlSRO
Page 7 of 10
STEP 7:
[STEP 4fl
PLACE BA pumps in FAST speed.
STANDARD: Hand switches for boric acid pumps are been placed in the
fast speed position (1-HS-62-230D & -232D).
COMMENTS:
STEP 8:
[STEP 4g] Throttle OPEN emergency borate valve I-FCV-62-
138 to maintain boric acid flow greater than 35 gpm.
STANDARD: I-HS-62-138A (Emergency Borate Valve), has been placed in
the OPEN position AND Fl-62-137A has been checked for
flow > 35 gpm. FCV-62-138 will not OPEN and the RNO
column must be entered.
COMMENTS:
NOTE:
Steps 9 through 12 of this JPM are the RNO steps for FR-SI,
Step 4g
STEP 9:
[STEP 4g RNO] IF BA flow less than or equal to 35 gpm:
THEM:
e
Locally QPEN emergency borate valve Z-FCV-62-138
[blender station elev 71 31 OR
STANDARD: An AUO has been directed lo open 1-FCV-62-138.
- CUE:
When notified as AUQ, acknowledge the report using
repeat back. Then report that 4-FCV-62-138 cannot be
opened locally from the push button or hand wheel.
COMMENTS:
-
UNSAT
-
UNSAT
I
-
UNSAT
5.l.a RO/SRO
Page 8 of 10
STEP 18:
[STEP 4g RNOJ a ALIGN manual boration:
1) Locally OPEN alternate boration valve 1 -ISV-62-929
[blender station eiev 7131.
STANDARD: An AUO has been directed to open 1-ISV-62-929. Step is
critical in that provides boration path from BAT to CCP.
When notified as AUO, acknowledge the report using
repeat back.
- CUE:
Then report that you have opened I-ISV- 62-929
COMMENTS:
CONSOL OPERATOR NOTE: Use Remote Function Page CV to Open
1-62-929 or insert mrf cvrl0 open.
STEP 11:
[STEP 4g RNO] 2) OPEN blender BA supply I-FCV-62-140
STANDARD: 1-HS-62-140D has been placedkhecked in the OPEN
position.
COMMENTS:
STEP 12:
[STEP 4g RNQ] 3) MONITOR BA flow.
STANDARD: BA Flow is checked on 2-FI-62-139 at > 35 gpm or the AUO at
local station has been notified to check BA flow.
If AUO contacted, report the flow is 38 gpm.
- CUE:
COMMENTS:
CRITICAL
STEP
-
SAY
-
UNSAT
-
-
UNSAT
-
-
UNSAT
STEP 13:
Notify the Unit Supervisor that the step 4 is complete.
STANDARD: The Unit Supervisor has been notified that Step 4 of FR-S.l
has been completed.
- CUE:
When notified, acknowledge the report using repeat
back.
COMMENTS:
END OF TASK
TIME STOP:
B.1 a ROlSRO
Page 9 of 10
-
-
UNSAT
CANDEDATE CUE SHEET
(TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)
DlRECTlQN PO TRAINEE:
I will explain the initial conditions, and state the task to be performed. All control
room steps shall be performed for this JPM, including any required
communications. I will provide initiating cues and reports on other actions when
directed by you. Ensure you indicate to me when you understand your assigned
task.
INITIAL CONDITIONS:
Unit in Mode 'I at 100% RTP
1-FI-62-139
%A TO BLENDER FLOW is OOS, being calibrated by IMs.
CCP 1 B-5 is out of service (hold order).
A valid Rx Trip First-Out Alarm (SIG low level) was received.
No Rx Trip occurred.
E-0 was entered and transition made to FR-§.I
The first three steps of FR-§.I have been completed.
The OAC will monitor the Rods inserting.
You are the CRO.
INITIATING CUES:
You are to perform boration of the RCS per FR-S.1 Step 4.
You are to notify the Unit Supemisor when the boration has been established.
B.7.b ROlSRO
Page 1 of 9
REGION ll
IN lTlAL LICENSE EXAM1 NATlO N
B.l .b RQiSRO JPMR022A
Place Excess Letdown In Service Per SO!-62.01
APPLICANT
EXAMINER
B.1.b ROlSRO
Page 2 of 9
REGION II
INITIAL LICENSE EXAMINATION
-
Task: Place Excess Letdown In Service Per $01-62.01
Alternate Path: N/A
Facility JPM #:
3-OT-JPMR022A Rev 2
WA RatinqW:
004 A 4.06 [3.6/3.1]
004 A 1 .I 1 [3.0/3.0]
004 A 2.22 [3.2/3.1]
2.2.30 [3.9/3.4]
2.1.23 [3.9/4.0]
004 A 2.22 [3.2/3.1]
Task Standard:
Excess Letdown has been placed in service per $01-62.01, Section 8.3
Preferred Evaluation Location:
Preferred Evaluation Method:
Simulator
In-Plant -
Perform
X
Simulate -
References: $01-62.01~ CVCS-Charging and Letdown, (Rev 46)
Task Number:: RO-062-$01-62-007
APPLICABLE FOR: RO/SRO
lOCFR55.45: 6, 12
Validation Time:
11 min. Time Critical: No
-_s-_____s-__--____----------------------------------------------~~--------
___________________--------------------------------------------------------
Applicant:
Time Start:
NAME
Time Finish:
Performance Ratina: SAT -
UNSAT __
Performance Time -
Examiner:
I
NAME
SIGNATURE
DATE
COMMENTS
B.1.b ROlSRO
Page 3 cf 9
SIMULATOR OPERATOR INSTRUCTIONS:
1, Initialize to IC 158.
2.
PLACE 1-FCV-62-59, EXCESS LETDOWN DIVERT in the DIVERT position.
3. Acknowledge all alans.
4.
Place simulator in FREEZE until the performer indicates an understanding of the
task.
5. NOTE: This JPM has been pre-shot in IC #158. Should IC #I58 be erased or fail
to perform as expected then use the following set-up instructions:
a. Initialize simulator to any at power maintained IC.
b. Isolate the following letdown and charging valves:
I-FCV-62-72
1-FCV-62-69
1 -FCV-62-70
1-FCV-62-73
1 -FCV-62-90
1-FCV-62-74
1 -FCV-62-9 1
1-FCV-62-76
c. Place 1-FCV-62-93 in manual and stabilize seal flow at 8 to 9 gpm per RCP
seal.
d. PLACE 1-FCV-62-59, EXCESS LETDOWN DIVERT in the DIVRT position.
e. Acknowledge all alarms.
f. Place the simulator in FREEZE until the performer indicates an understanding
of the task.
g. After performer indicates understanding of the task, place simulator to RUN.
SIMULATOR OPERATOR INSTRUCTIONS:
None
B.1.b RB/SRO
Page 4 of 9
ToollslEauipmentlProcedures Needed:
Ensure clean copy of Sol-62.01 in all copies of System Operating lnstructions on the
Simulator Floor.
READ TO OPERATOR
DIRECTION TO TRAINEE:
I will explain the initial conditions, and state the task to be performed. All control
room steps shall be performed for this JPM, including any required
communications. I will provide initiating cues and reports on other actions when
directed by you. Ensure you indicate to me when you understand your assigned
task. To indicate that you have completed your assigned task return the handout
sheet I provided you.
INITIAL CONDITIONS:
The Unit is operating at power.
A small leak has been found on the normal letdown path
Letdown and Charging have been isolated.
You are the Operator at the Controls.
The RABCON Supervisor has been informed of the intent to establish Excess Letdown.
INITIATING CUES:
The Unit Supervisor has directed you to establish Excess letdown to the VCP per
procedure.
YOU are to notify the Unit Supervisor when the procedure has been compketed.
B.1.b RO/SRB
Page 5 of 9
START TIME:
STEP 1:
Obtain a copy of the procedure.
XANBARD: A copy of SOI-62.01, Section 8.3 has been obtained.
XIMMENTS:
--
CAUTION 1 RCP Seal leakoff flow must be within lit~& specified
in Appendix B of SOl-68.02, according to the #I
seal
differential pressure. As excess letdown is placed into
service, the #I seal leafoff flow could potentially fall
below the limits.
CAUTION 2 With normal Letdown isolated, C,
may only be raised
small amounts, to avoid excessive letdown to the
RCDT.
NOTE 1 RADCON Shift Supervisor should be notified of intent to place
NOT 2 Charging and RCP seal flow must be manually controlled.
excess Letdown in service.
STEP 2: [STEP I] OPEN Excess LDHX CCS valves:
NO MEN C U T
EXC LTDN HX OUT CI
STANDARD: 1-HS-70-143A and 1-HS-78-85A placed in the OPEN
position. Step is critical to establish cooling water flow to
the letdown heat exchanger.
COMMENTS:
__ SAT
__ UNSAT
CRlTlCAL
STEP
-
__ UNSAT
%.
STEP 3:
[STEP 21 CHECK I-HS-62-59A, CVCS EXCESS
LETDOWN DIVERT FLOW CNTL, aligned to one of the
following (N/A choice NOT aligned):
[a] NORM
[b] DIV
STANDARD: 1-HS-62-59A has been placed to the NORM position.
Step is critical to allow excess letdown to be aligned to
VCT per task assignment.
COMMENTS:
NOTE As VCT level rises, 1-LCV-62-118, .LETDOWN DIVERT TO
HUT, Auto Diverts to HUTS.
STEP 4:
[STEP 31 PERFORM the following:
STANDARD: I-HS-62-54A and I-HS-62-55A have been placed in the
OPEN positions. Step is critical to establish excess
letdown Row path from RCS to VCT.
COMMENTS:
E.1.b ROlSRO
Page 6 of 9
CRITICAL
STEP
-
-
UNSAT
CRITICAL
STEP
~
__ UNSAT
B.1.b ROlSRO
Page 7 of 9
CAUTION
xcess letdown design flow is 20 gpm. Preop W-2.2
determined that 1-FCV-62-56, CVCS EXCESS
LETDOWN FLOW CONTROL, can pass up to 50 gprn
(depending on RCS pressure and I-HIC-62-56A
output), which could cause higher than designed
excess letdown and CCS temperature.
NOTE
If excess letdown is being placed in service in preparation
for 1-TRl-62-901, flow may be maintained at a small value
to allow piping and the heat exchanger to remain at an
elevated temperature and pressure
step
EVALUATOR MOTE: Steps 5 and 6 are both part of the same instruction
STEP 5:
[STEP 41
SLOWLY OPEN I-HIC-62-56A, EXCESS
LTDN FLOW CONTROL,
STANDARD: 1-FCV-62-56 has been throttled open using 1 -HIC-62-568
Step is critical to establish excess letdown flow path
flow path to RCS.
COMMENTS:
STEP 6:
[STEP 41 to maintain Excess LD Hx Outlet temperature
below 206°F and Excess LD Hx CCS Qutiet temperature
below 135 "F
STANDARD: I-TI-62-58 on 1-M-5 has been checked below 206°F and
1-TI-70-86 on 0-M-27 has been checked below 135°F.
COMMENTS:
CRITICAL
STEP
-
UNSAT
-
-
UNSAT
B.1.b ROSRO
Page 8 of 9
STEP 7:
STANDARD:
- CUE:
Notify the Unit Supervisor that the step 4 is complete.
The Unit Supervisor has been notified that Step 4 of FR-S.l
has been completed.
When notified, acknowledge the report using repeat
back.
COMMENTS:
END OF TASK
TIME STOP:
_I SAT
I
UNSAT
APPLICANT CUE SHEET
(TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)
DIRECTION TO TRAINEE:
I will explain the initial conditions, and state the task to be performed. All control
room steps shall be performed for this JPM, including any required
communications. B will provide initiating cues and reports on other actions when
directed by you. Ensure you indicate to me when you understand your assigned
task.
INITIAL CONDITIONS:
The Unit is operating at power.
A srnali leak has been found on the normal letdown path.
Letdown and Charging have been isolated.
You are the Operator at the Controls
The RADCON Supervisor has been informed of the intent to establish Excess Letdown.
INITIATING CUES:
The Unit Supervisor has directed you to estabtisk Excess letdown to the VCT per
procedure.
You are to notify the Unit Supervisor when the procedure has been cornpkted.
B.l .c ao/sao
Page 2 of 1 1
REGION I1
INITIAL LICENSE EXAMINATION
Task: Align SI pumps for Hot Leg Recirculation per ES-I .4
Alternate Path: N/A
Facility JPM #:
New
KIA Ratinn(s):
006 A 3.03 [4.1/4.1j
006 A 4.01 [4.1/3.9j 006 A 4.02 [4.0*/3.8]
006 A 4.04 [3.7*/3.6] 006 A 4.08 f4.214.31 2.1.20 [4.3/4.2]
2.1.23 [3.9/4.0]
2.1.31 [4.2/3.9]
The SI pumps have been aligned for hot leg recirculation per ES-1.4 Step 3
Task Standard:
Preferred Evaluation Location:
Preferred Evaluation Method:
Simulator
In-Plant __
References: E§-I .4
Transfer To Hot Leg Recirculation Rev. 9
Task Number:: 88-1 13-ES-1.4-001
APPLICABLE FOR: ROlSRQ
1OCFR55.45: 3, 6. 7, 8
Validation Time: 6 min.
Time Critical: No
Perform
X
Simulate -
_-_-__-----__-________sssss_______---------------_-_-------------_---
sss________-____________________________------------------------_----------
Candidate:
Time Start:
NAME
Time Finish:
Performance Ratincl: SAT -
UNSAT __
Performance Time -
Examiner:
/
NAME
SIGNATURE
DATE
E.1 .c ROlSRO
Page 3 of 11
SIMULATOR OPERATOR INSTRUCTIONS:
1.
initialize to IC # 159.
2.
Acknowledge all alarms and clear motor trip-out white lights.
3.
After performer indicates understanding of task, place simulator in RUN
4. This JPM has been pre-shot in IC # f59. Should IC # 159 be erased or fail to
perform as expected then use tRe foilowing set-up instructions:
Initialize to IC-50.
Insert imf thofa 100 @ 100% Severity ( Hot beg Break Loop 2).
stop RCPs.
Insert rfi sir14 to on (Restore power to FCV-63-1).
Insert rfi sir06 to on (Restore power to FCV-63-22).
Insert rfi sir0l to on (Restore power to C I A FCVs 63-67, 80, 98, 11 8)
Ensure I-FCV-1-153 (CCS to RHR Hx) is OPEN.
C6ose 1-HS-70-207 (CDWE Supply from Hdr 1B).
Ensure CCS flows and pressures stabilize.
Alarm Silence Generator Gore Monitor Alarm
Perform transfer tu Containment Sump, steps 1 through 28 of ES-I .3
Place simulator to FREEZE after transfer complete.
SIMULATOR OPERATOR INSTRUCTIONS:
None
[NOTE: Operator actions for this task are considered important by the WBN PRA with
respect to Core Damage Frequency.]
B.1.c RB/SRO
Page 4 of 11
Tool~lEquipmenffProcedures Needed:
Ensure clean copy of E§-1.4 in the simulator copies on the Simulator Floor.
READ TO OPERATOR
DIRECTION TO TRAINEE:
I will explain the initial conditions, and state the task to be performed. All control
room steps shali be performed for this JPM, including any required
communications. I will provide initiating cues and reports on other actions when
directed by you. Ensure you indicate tu me when you understand your assigned
task. To indicate that you have completed your assigned task return the handout
sheet I provided you.
INITlAL CONDITIONS:
A Large Break LOCA has occurred
Three (3) hours has elapsed since the Large Break LOCA occurred
E-? had been entered and all steps through 31b have been completed.
RHR has been aligned for hot leg recirculation per ES-1.4 Step 1.
You are the Operator at the Cuntrols.
INlTlATlNG CUES:
The Unit Supervisor directs you to align SI pumps for hot leg recirculation
per ES-1.4 Step 3.
You are to notify the Unit Supervisor when Step 3 is complete.
B.l.c ROlSRO
Page5of 11
START TIME:
STEP 1:
EXAMINER'S CUE: After the performer has identified the correct
instruction, the evaluator can provide a copy of
the instruction.
Obtain a copy of the appropriate procedure.
STANDARD: A copy of ES-1.4 has been obtained.
COMMENTS:
STEP 2:
[9 ALIGN SI pumps for hot leg recirc:
a. STOP SI pump A-A.
STANDARD: SI pump IA-A is stopped with 1-HS-63-IOA. Step is
critical since following step isolates the SI pump's
discharge. Recirc path to RWST was isolated in ES-
1.3.
COMMENTS:
I
UNSAT
CRITICAL
STEP
-
__ UNSAT
- Italicized Cues Are To Be Used Only If JPM Performance Is Being Simulated.
B.2.c ROlSRO
Page 6 of 41
STEP 3:
[3.b] CLOSE Train A crosstie valve 1-FCV-63-152
STANDARD:
I-HS-63-152A is placed to the close position and green
valve position indicating light is verified ON, red valve
position light OFF on respective valve hand switch. Step
is critical to isolate SI pump A-A discharge from SI
pump 1B-B discharge.
COMMENTS:
STEP 4:
[3c] OPEN Train A hot leg injection valve 1-FCV-63-156.
STANDARD: 1-HS-63-1568 is placed to the open position and red valve
position indicating light is verified ON, green valve position
light OFF on respective valve hand switch. Step is critical
to align SI pump A-A discharge to RCS hot legs 1 & 3.
COMMENTS:
CRITICAL
STEP
__ SAT
-
UNSAT
CRITICAL
STEP
I
_I UNSAT
- italicized Cues Are To Be Used Only MJPM Petformame Is Being Simulated.
6.l.c RO/SRO
Page 7 of 11
STEP 5: 3 4 START SI pump A-A.
STANDARD: SI pump 1A-A is started with 1-HS-63-1OA. Step is
critical to establish SI pump A-A flow to RCS hot legs 1
& 3.
COMMENTS:
STEP 6:
[3e]
ENSURE Train A hot leg flow on 1-FI-63-152.
STANDARD: Performer ensures Train A hot leg flow is indicated on 1-
COMMENTS:
STEP 7:
[3fl
STOP SI pump 3-B.
STANDARD: SI pump 15-5 is stopped with 1-HS-63-15A. Step is
critical since following step isolates the SI pumps
discharge. Recirc path to RWST was isolated in ES-
z .3.
COMMENTS:
CRITICAL
STEP
__ UNSAT
-
UNSAT
CRITICAL
STEP
-
-
UNSAP
- Italicized Cues Are To Be Used Only If JPM Performance Is Being Simulafed.
B.1.c ROlSRO
Page 8 of 11
STEP 8:
[3gl CLOSE Train S crosstie valve 1-FCV-63-153.
STANDARD: 1-HS-63-153A is placed to the close position and green
valve position indicating light is verified ON, red valve
position light OFF on respective valve hand switch. Step is
critical to isolate SI pump 1B-B discharge from SI pump
1A-A discharge.
NOTE TO EVALUATOR: Step is critical if Operator has not closed the
COMMENTS:
Train A crosstie valve I-FCV-63-152. (JPM Step 3).
STEP 9:
[3h] OPEN Train 5 hot leg injection valve 1-FCV-63-259
STANDARD: 1-HS-63-153A is placed to the open position and red valve
position indicating light is verified ON, green valve position
light OFF on respective valve hand switch. Step is critical
to align SI pump A A discharge to RCS hot legs 2 i3 4.
COMMENTS:
1 COMMENTS:
CRITICAL
STEP
-.
-
UNSAT
CRETICAL
STEP
-
I
UNSAT
- l&alicized Cues Are To Be Used Oniy If SPM Performance Is Being Simulated.
B.1.c ROlSRO
Page 9 of 11
[3i] START SI pump B-B.
STANBARD: SI pump 1B-B is started with 1-HS-63-158. Step is
critical to establish Si pump 1B-E3 flow to RCS hot legs
2 & 4.
COMMENTS:
STEP .% 1:
[3j] ENSURE Train E? hot leg flow on 4-Fi-63-20
STANBARD:
Performer ensures Train 5 hot leg flow is indicated on
f-FI-63-20 (SI PMP B FLOW).
COMMENTS:
STEP 12:
[3k] ENSURE power restored to 1-FCV-63-22 using
Appendix A (ES-1 A), 1-FCV-63-22 Breaker
Operation.
STANRARR: Performer AUO to restore power to 1 -FCV-63-22 in
accordance with Appendix A of ES-I .4.
- CUE:
If asked, State to power was restored to 1-FCV-62-22
per Appendix D of E-I.
COMMENTS:
CRITICAL
STEP
-
-
UNSAT
-
I
UNSAT
-
-
UNSAT
- Italicized Cues Are To Be Used Only If JPM Performance Is Being Simulated.
B.1.c RO/SRO
Page 10 of 11
STEP 13:
[31]
CLOW SI pump cold leg injection valve l-FCV-63-
22.
STANDARD: 1-HS-63-228 is placed to the close position and green
valve position indicating light is verified ON, red valve
position light OFF on respective valve hand switch.
- CUE:
After valve has been closed, state to performer that
another operator will complete procedure, this JPM
is complete. We will stop here.
COMMENTS:
END OF TASK
TIME STOP:
- Italicized Cues Are To Be Used On/y If JPM Performance Es Being Simdated.
APPLICANT CUE SHEET
(TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)
DlRECTlON TO TRAINEE:
I will explain the initial conditions, and state the task to be performed. All control
room steps shall be performed for this JPM, including any required
communications. I will provide initiating cues and reports on other actions when
directed by you. Ensure you indicate to me when you understand your assigned
task. To indicate that you have completed your assigned task return the handout
sheet I provided you.
INITIAL CONDITIONS:
A Large Break LOCA has occurred.
Three (3) hours has elapsed since the Large Break LOCA occurred.
E-I had been entered and all steps through 31b have been completed
RHR has been aligned for hot leg recirculation per §-I
.4 Step 1.
You are the Operator at the Controls.
INlTlATlNG CUES:
The Unit Supervisor directs you to align SI pumps for hot leg recirculation
per 25-1.4 Step 3.
YOU are to notify the Unit Supervisor when Step 3 is complete.
B.1.c ROlSRO
Page I of 11
REGION ll
I M IT1 AL L I C E N S E EXAM I N AT f 0 N
B-1 .c RO/SRO JPMR071 B
Align SI Pumps for Hot Leg Recirculation per ES-1.4
APPLICANT
--
-
EXAMlNER
B.1.d BOER0
Page I
of 13
REGION II
INITIAL LICENSE EXAMINATION
B.1 .d ROISRO JPMR075
Remove One RCP From Service (P
P8) Per AOi-5
APPLICANT
EXAMINER
B.1.d RB/SRO
Page 2 of 13
REGION II
INITIAL LICENSE EXAMINATION
Task: Remove One RCP From Service (<P-8) Per AOB-5
Alternate Path: No
Facility JPM #:
3-OT-JPMR075 Rev 2
WA Ratlngls):
017 AA 1.85 [3.813.8]
017 AA 1.13 [3.4/3.4] 017 AA 1.08 [3.0*/2.9]
019 AB 1.20 [2.7/2.7]
017 AA 1.22 [4.0/4.2]
2.4.4 [4.0/4.3]
Task Standard: Reactor Coolant Pump #3 has been shutdown without a Hi-Hi Steam
Generator Level occurring in #3 SIG per AOI-5.
Preferred Evaluation Location:
Simulator
In-Plant __
Preferred Evaluation Method:
Perform
X
Simulate __
Candidate:
Time Start:
NAME
Time Finish:
Performance Ratina: SAT ___ UNSAT
~
Performance Time -
COMMENTS
SIMULATOR OPERATOR INSTRUCTIONS:
1.
Initialize to IC # 162.
B.1.d ROlSRO
Page 3 of I 3
2. Acknowledge all alarms.
3. After performer indicates understanding of task, place simulator in run.
4. NOTE: This JPM has been pre-shot in IC #I62 Should IC #I62 be erased OF fail
to perform as expected then use the following set-up instructions:
a.
Initialize to I C 4
b.
Reduce load to = I 5 % and then place rod control into manual and transfer
steam dumps to pressure mode.
Reduce reactor and turbine load to approximately 9%
c.
d. Insert the following overrides:
ior zaoti6229 220
ior zaoti6230 220
e
ior an:ov:14c090 on
e. Place simulator to FREEZE.
f.
Place simulator in run when directed by the examiner.
SIMULATOR OPERATOR INSTRUCTIONS:
NONE
B.1.d ROlSRO
Page 4 of 13
ToolslEquipmentlProcedures Needed:
Ensure clean copy of AQt-5 in all copies of Abnormal Operating Instructions on the
Simulator Floor.
READ TO OPERATOR
DIRECTION TO TRAINEE:
I will explain the initial conditions, and state the task to be performed. All control
room steps shall be performed for this JPM, including any required
communications. I will provide initiating cues and reports on other actions when
directed by you. Ensure you indicate to me when you understand your assigned
task. To indicate that you have completed your assigned task return the handout
sheet I provided you.
INITIAL CONDITIONS:
Unit is at approximately 9% RTP
RCP #3 Pump Bearing Temperature is high
RCP lf3 Restart is planned after brief entry into containment.
You are the Operator at the Controls.
INITIATING CUE3
The Unit Supervisor has directed you to remove RCP #3 from service according
to A014 Section 3.2.
You are to notify the Unit Supervisor when ready to transition to Section 3.4, RCP
RESTART.
B.1 .d ROlSRO
Page 5 of 13
START TIME:
STEP 1:
Obtain a copy of the procedure.
STANDARD: A copy of AO8-5 Section 3.2 has been obtained.
EXAMINERS CUE: Afier fhe performer has identified the correct
instruction, the evaluator can provide a copy of the
instruction.
COMMENTS:
CAUTION
Following the shutdown of the RCP, the affected
loop Tavg may drop below Tcold in the active
loops. Tavg will recover to a value equal to
Tcold in the active loops fslbwing isolation of
feedwater to the affected SIG.
As affected SG RCS loop flow reverses, steam
flow will drop to zero. SG level will initially drop
due to shrink from loss of RCS heat input and
then rise if feed flow continues.
N O E S
Malfunctions addressed by this procedure require RCP
shutdown as soon as possible following a rapid load
reduction.
Exceeding any of the limits listed on Attachment 1 of this
procedure will require immediate shutdown of the affected
RCP.
a
Malfunctions resulting in high #I
seal leakoff will require
closing #I
seal return FCV following RCP coastdown.
-
-
UNSAT
- ltaRicized Cues Are To Be Used Only If JPM Performance Rs Being Simulated.
B.1.d ROISRB
Page 6 of 43
NOTE TO EVALUATQR: :Evaluator wiEl need to give the following cue
iflwhen the candidate refers to the ICs screen for RCP #3:
- CUE: State that the plant computer indications for seal
leakoff and pump bearing temperature are reading EJ
220 "F.
STEP 2:
[Step I] CHECK RCP immediate shutdown required.
- REFER TO ATTACHMENT 1, RCP Immediate Shutdown
Criteria.
STANDARD: Performer refers to Attachment 1 and determines that
immediate shutdown is not required, but RCP bearing
temperature is = 220 T and seal outlet temperature is = 220
OF. by checking 1-TI-62-29 and 1-TI-62-30.
- CUE:
When contacted role play as appropriate andstate that
shaff vibration is 8 mils and stable, and frame vibration
js 0.8 mils and stable.
COMMENTS:
STEP 3:
[Step 1 RNQ] MONITOR RCP immediate shutdown
Criteria:
- IF RCP shutdown required, THEN PERFORM Step 2.
GOT0 Step3.
STANBARB: Performer determines that immediate shutdown is not
required, and proceeds to Step 3.
COMMENTS:
-
-
UNSAT
- italicized Cues Are To Be Used Only If JPM Performance is Being Simulated.
B. 1 .d ROlSRO
Page 7 of 13
STEP 4:
[Step 31 REDUCE reactor power to less than 10% to ailow
removal of one RCP.
REFER TO AOI-39, Rapid Load Reduction.
REFER TO GO-5, Unit Shutdown from 30 % Reactor
Power to Hot Standby.
STANDARD: Performer checks the following parameters and determines
that reactor power is less than $0% (also given in initial
conditions) and continues to next step:
Power Range channels 1-NI-41B, -428, -438,
-44B
LOOP AT I-T1-68-2D, -25D, 44D, -67D.
COMMENTS:
i
I
STEP 5:
[Step 41
DO NOT CONTINUE this instruction UNTIL
reactor power is iess than 10%.
~
STANDARD: The performer has determines that power is less than 15%
(from previous step) and continues to next step.
COMMENTS:
I
-
_I UNSAT
-
-
UNSAT
- lfalicized Cues Are To Be Used Only If JPM Performance ls Being Simulated,
B.1.d ROlSRO
Page 8 of 13
STEP 6:
[Step 51
CHECK if RCP restart is possible:
0
Limiting condition for pump operation can be
immediately resolved.
STANDARD: The performer determines from initial conditions that
immediate restart is planned or performer checks with Unit
Supervisor to determine if RCP restart is possible.
If asked respond as Unit Supervisor that RCP
immediate resfart is planned foSrlowing containment
entry.
- CUE:
COMMENTS:
STEP 7:
[Step 61
WHEN reactor power less than to IO%, THEN:
a. DEFEAT IOOP
signals to Tavg and AT auctioneer
units for affected loop.
STANDARD: 1-XS-68-2D and 1-XS-68-2M have been placed in the
LOOP 3 position and then pulled out. This step is critical
to remove loop three signals from Tavg and delta T
auctioneer units.
COMMENTS:
STEP 8:
[Step 6 continued]
b. ENSURE control rods in
MANUAL.
STANDARD: Rod Bank Select switch 92-RESS) on 1-M-4 has been
checked in MANUAL.
COMMENTS:
-
UNSAT *
CRITICAL
STEP
-
-
UNSAT
-
-
UNSAT
- Italicized Cues Are To Be Used O ~ l y
If JPM Performance Is Being Simulated.
B.1.d ROlSRO
Page 9 of 13
STEP 9:
[Step 6 continued]
valve in MANUAL and raise level in affected SIG to 60% narrow
range.
C. PLACE affected loop bypass reg
STANDARD:
The #3 SIG level is raised to 80% narrow range by manually
opening the MFW bypass reg. Valve 1-LIC-3-90A.
COMMENTS:
STEP I O :
[Step 6 continued]
d. STOP affected RCP.
STANDARD: 1-HS-68-50BA has been placed in MANUAL position
(pushed in). 1-HS-68-50AA, #3 RCP Normal Bkr
Handswitch has been placed in STOP position. This step
is critical In stopping affected RCP.
COMMENTS:
-
_. UNSAT
CRITICAL
STEP
__ SAT
__ UNSAT
- Italicized Goes Are To Be Used Onry If JPM Performance Is Being Simulated.
t3.l.d ROISRB
Page 10 of 13
NOTE TO EVALUATOR: Applies to following steps; Steam flow
indications are initially off-scale !OW, and will come on-
scale after the #3 RCP is stopped. Flow indications may
fluctuate on and off scale.
STEP 11:
[Step 71
MAINTAIN affected SG level on PROGRAM:
LOWER MFW flow as steam flow drops.
STANDARD: The feedwater flow to #3 S/G is reduced to prevent #3 SIG
level from rising by manualiy closing the MFW bypass reg.
Valve with 1-LIC-3-90A. This step is critical to prevent
SIG overfill as steam flow lowers from SIG #.
COMMENTS:
STEP 12:
[Step 81
ISOLATE blowdown from affected SG
STANDARD: #3 SIG blowdown is isolated by piacing I-HS-1-25/183 in
close. This step is critical to prevent SIG low level.
COMMENTS:
CRITICAL
STEP
-
UNSAT
CRITICAL
STEP
- ltaiicized Cues Are TQ Be Used Qnly If JBM Performance Is Being Simulated.
B.1 d ROISRO
~
P x l 1 of 13
STEP 13:
[Step 91
a.
b.
CLOSE affected spray valve.
IF RCP 1 OR 2 was stopped, THEN:
PLACE affected pzr spray controller in MANUAL
STANDARD: Performer determines that #3 RCP was stopped; therefore
NO action is required by this step.
COMMENTS:
STEP 14:
[Step I O ] REFER TO Tech Specs:
LCO 3.4.1, RCS Press, Temp and Flow DNB Limits.
0
RCS Minimum Temp For Critically.
LCO 3.4.4, RCS Loops Modes 1 and 2.
STANDARD: Performer refers to Tech Specs OR notifies US to refer to
Tech Specs.
- CUE:
When performer refers to Tech Spec or Unit
Supervisor is directed to refer to Tech Spec, state that
the Unit Supervisor will research Tech Specs.
COMMENTS:
-
-
UNSAT
-
UNSAT
- Italicized Cues Are To Be Used Only If JPM Petformame Is Being Simulated.
B.1.d ROlSRO
Page 12 of 13
STEP 15:
[Stepll]
CHECK RCP restart criteria:
Plant conditions stable.
0
RCP ready for restart.
STANDARD: Performer determines Plant conditions are stable and RCP
ready for restart.
- CUE: When performer asks Unit Supervisor when the RCP
will be ready for RESTART, or QPS Supt approval is
sought for RESTART, then state this JBM has been
completed. We will stop here.
COMMENTS:
END OF TASK
TIME STOP:
-
-
UNSAT
- Italicized Cues Are To Be Used Only \\f JPM Performance is Being Sirnulafed.
APPLICANT CUE SHEET
(TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)
DIRECTION TO TRAINEE:
I will explain the initial conditions, and state the task to be performed. A11 control
room steps shall be performed for this JPM, inchding any required
communications. B will provide initiating cues and reports on other actions when
directed by you. Ensure you indicate to me when you understand your assigned
task. To indicate that you have completed your assigned task return the handout
sheet I provided you.
INITIAL CONDITIONS:
Unit is at approximately 9% RBP
RCP #3 Pump Bearing Temperature is high
RCP #3 Restart is planned after brief entry into containment.
You are the Operator at the Controls.
INITIATING CUES:
The Unit Supervisor has directed you to remove RCP #3 from service according
to 4401-5 Section 3.2.
You are to notify the Unit Supervisor when ready to transition to Section 3.4, RCP
RESTART.
B. 1 .e ROlSRO
Page I
of 9
REGION II
INITIAL LICENSE EXAMINATION
B.1 .e ROiSRO JPMRI29A
Return the PRT to Normal per Sol-68.01
APPLICANT
EXAM!"?
B.l.e ROWRO
Page 2 of 9
REGION II
INITIAL LICENSE EXAMINATION
-
Task: RETURN THE PKT TQ NORMAL PER Sol-68.01
Alternate Path:
1-PCV-68-340 fails open after PRT is cooled requiring performer to respond
by attempting closure of its associated motor operated block valve. A
manual reactor trip and safety injection will be required (auto reactor trip and
auto SI have been defeated).
Facilitv JPM #:
3-0T-JPMR129A Rev 1
KIA Ratinds):
010 A 1.03
(2.913.2)
2.1.23
(3.914.0)
2.1.28
(3.213.3)
002 K 1.05
(3.Z3.4)
Task Standard:
PRT cooling is established and the level is being maintained per SQI-68.01.
Performer attempts closure of 1-FCV-68-333 then manually trips the reactor
and manually initiates SI.
Preferred Evaluation Location:
Preferred Evaluation Method:
Simulator
In-Plant __
Perform
X
Simulate
~
References: SQ1-68.01 "Reactor Coolant System Pressurizer Relief Tank" Rev. 40
Task Number:: RQ-068-Sol-68-006
APPLICABLE FOR: ROISUO
1OCFR55.45:
2, 3, 4, 6
Validation Time: 15 min. Time Critical: No
_______---______________________________----------------------------------
___-__________--_----------------------------------------------------------
Candidate:
Time Start:
NAME
Time Finish:
Performance Ratins: SAP -
UNSAT -
Performance Time -
Examiner:
NAME
I
SIGNATURE
BATE
COMMENTS
B.1.e ROISRQ
Page 3 of 9
SIMULATOR OPERATOR INSTRUCTIONS:
1.
Initialize to IC # 163
2.
Acknowledge all alarms.
3.
Freeze simulator until the performance indicates understanding of the task and time
is ailowed for control board familiarization.
4. NOTE: This JPM has been preshot in IC #163. The following is the setup instructions
if needed:
Initialize to IC # 50.
Brain PRT to slightly <70% with 1-HS-68-318
Open and close PZF PQRV (without tripping reactor) until PWT temperature is
approximately 120°F.
Allow pressurizer pressure to return to normal.
Close both valves after pressure is lowered.
Insert the following override: ior zdihs68333a open to fail open 1-FCV-68-333
Block valve for 1-PCV-68-340.
Insert the following malfunctions:
irnf rp0lb Automatic Reactor Trip Signal Failure
irnf sp02b Auto SI initiation Signal Failure
irnf rc07b (ea) 1QQ to fail 1-PCV-68-340 to 100% assigned to event trigger 1,
Acknowledge all alarms
5. After performer indicates understanding of task, place simulator in run.
SIMULATOR OPERATOR INSTRUCTIONS:
After completion of JPM Step 5 or when cued by evaluator then enter the following
malfunction trigger: irnf itrigger to fail PQRV 68-340 to 100%.
B.1.e ROlSRO
Page 4 Qf 9
ToolslEsuignaenffProcedures Needed:
Ensure clean copy of SO%-68.01 in all copies of Operating Instructions on the Simulator
Floor.
READ TO OPERATOR
DlRECTlON TO TRAINEE:
I will explain the initial conditions, and state the task to be performed. All control
room steps shall be performed for this JPM, including any required
communications. I will provide initiating cues and reports an other actions when
directed by you. Ensure you indicate to me when you understand your assigned
task. To indicate that you have completed your assigned task return the handout
sheet E provided you.
INITIAL CQNDITIQNS:
The Unit is at 100% RTP
Leakage past a Pressurizer PQRV has caused the PRT temperature to go up to
120°F.
You are the Operator at the Controls (OAC).
INITIATING CUES:
The Unit Supervisor has directed you to cool the PRT to normal per the
appropriate SO!.
You are to notify the Unit Supervisor when the conditions in the PRT are normal.
B.1.e ROISRQ
Page 5 of 9
START TIME:
STEP 1:
Obtain a copy of the procedure.
STANDARD: A copy of Sol-68.01 section 8.3 has been obtained.
EXAMINERS CUE: After the performer has demonstrated the method of
obtaining the correct instruction, the evaluator can
provide a copy of the instruction.
COMMENTS:
STEP 2:
[Step I] PERFORM the following:
[a] NOTIFY UO of the anticipated primary water usage.
[b] ENSURE Primary Water is aligned per Sol-81.01.
[c] ENSURE a Primary Makeup Water Pump is running.
[d] ENSURE the non-running Primary Makeup Water Pump
handswitch is in P-Auto.
STANDARD: Performer determines that primary water makeup pump is
aligned normal with Primary Water Pump A in service by
checking red light LIT on 1-HS-82-3A and that Primary Water
Pump B is off by checking green light LIT on 1-HS-81-7A with
associated handswitch in P-AUTO (pulled cut or pulled up).
- CUE:
State to performer that Primary Water is aligned per SO[-
81.01.
COMMENTS:
-
-
UNSAT
- Italicized Cues Are To Be Used Onry If JPM Performance Is Being Simulated.
5.l.e RO/SRO
Page 6 of 9
NOTE 4:
Reduced Primary Water header pressure in the following step
may require the non-running Primary Water Pump to be
started.
STEP 3:
[Step 21 IF PRT temperature rises to 12OoF, THEN
PERFORM the following:
CRITICAL
STANDPIPES
1-M-5
OPEN
STANDARD: 1-FCV-81-12 and I-FCV-68-303 are opened by placing I-HS- 81-12A and 1-HS-68-3038 to the open position and verified
open by red indicating lights LIT on associated valve hand
switches. Step is critical provide flow path for cooling
water to the PRT.
CQMMENTS:
-
_. UNSAT
- italicized Cues Are Po Be Used only If JBM Performance Is Being Simulated.
B.l .e ROlSRO
Page 7 of 9
STEP 4:
[STEP 31 WHEN PRT level rises to 8Q% OR PRT temperature
12OoF, THEN PERFORM the following:
STANDARD: When PRT level increases to 80% or if PRT temperature falls
below 120°F, the performer will close 1-FCV-81-12 and I-FCV- 68-303 placing l-HS-81-12A and 1-HS-68-3038 to the close
position and verify valves are closed by green indicating lights
LIT on associated valve hand switches. Step is critical to
prevent PRT level increase above 80% or reduce primary
water usage when tank is less than 120°F.
COMMENTS:
STEP 5:
[Step 41 NOTIFY U.8. to ENSURE ONE Primary Water Pump
STOPPED and handswitch in Manual.
STANDARD: Performer stops, if necessaryy, one primary water makeup
pump if the P-AUTO pump started with I-HS-81-7A by pushing
in switch and going to stop, then returns switch to MANUAL
(pushed in or pushed down).
COMMENTS:
CRITICAL
STEP
-
-
UNSAT
-
-
UNSAT
- Italicized Cues Are TO Be Used Only I f JPM Performance Is Being Simulated.
E.1.e ROlSRO
Page 8 of 9
STEP 6:
[Step 51 IF required, THEN PERFORM Section 8.1, Return
PRT Level to Normal from High Level.
STANDARD: Performer determines that Section 8.1 doesldces not need to
be performed to lower PRT level. Outcome depends on level
in tank.
COMMENTS:
NOTE TO EVALUATOR: CUE console operator for trigger 1. imf itrigger to
fail P O W 68-340 fully open.
STEP 6:
Initiate Reactor Trip and Safety Injection and GO TO E-0,
Reactor Trip and Safety Injection.
STANDARD: Performer determines that a PORV 68-340 has faiied open, and
attempts to close the valve and its associated block valve with
1 -HS-68-334AA and 1-HS-68-333A. Performer determines
that PORV and its associated block valve will not close.
Performer announces this to the Unit Supervisor. Performer
determines that RCS pressure is rapidly lowering based on
observation of PZR Pressure Indications and recorders.
Performer initiates a manual trip and safety injection with hand
switches 7-RP-l or 2 and 1-HS-63-133B or 133A. This step is
critical in response to pressurizer small break LOCA.
- CUE: After performer has manually tripped the reactor and
initiated safety injection, then state to performer This
JPM has been completed. We will stop here.
COMMENTS:
END OF TASK
TIME STOP:
-
_I UNSAT
CRITICAL
STEP
I
-
UNSAT
- Mahized Cues Are To Be Used Only If JPM Performance Is Being Simulated.
APPLICANT CUE SHEET
(TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)
DIRECTION TO TRAINEE:
1 will explain the initial conditions, and state the task to be performed. AI% control
room steps shall be performed for this JPM, including any required
communications. I will provide initiating cues and reports on other actions when
directed by you. Ensure you indicate to me when you understand your assigned
task. To indicate that you have completed your assigned task return the handout
sheet I provided you.
INITIAL CONDITIONS:
The Unit is at 100% RTP
Leakage past a Pressurizer PORV has caused the PRT temperature to go up to
120°F.
You are the Operator at the Controls (OAC).
INITIATING CUES:
The Unit Supervisor has directed you to cool the PRT to normal per the
appropriate Sol.
You are to notify the Unit Supervisor when the conditions in the PRT are normal.
REGION II
B.1.f RQ/SRO
Page 1 of 9
INITIAL LICENSE EXAMINATION
B.1.f ROISRO JPMRO16A
Place RHR Spray in Service per FR-Z.1
APPLICANT
EXAMINER
B. 1 .f ROlSRO
Page 2 of 9
REGlQN II
INITIAL LICENSE EXAMINATION
Task: Place RHR Spray in Service Per FR-Z.1
Alternate Path: When 1-FCV-72-41 starts to open in the sequence to align the "B" Train RHR
for spray, the 18-5 RHR pumps trips, this required RNO response to get " A
train RHR spray in service.
3-OT-JFMROIGA Rev 4
Facility JPM #:
KIA Ratinq4s.):
005-A4.01 [3.6/3.4]
2.1.20 [4.3/4.2]
2.1.30 [3.9/3.4]
2.1.31 [4.2/3.9]
Task Standard:
Preferred Evaluation Location:
Preferred Evaluation Method:
Simulator
In-Plant ___
Perform
X
Simulate __
References: FR-Z.1, High Containment Pressure, (Rev 8)
Task Number:: RO-113-FR-Z.1-002
APPLICABLE FOR: ROlSRO
1OCFR55.45: 3, 4, 6, 7, 8
Validation Time: 10 min. Time Critical: No
Train "A" of RHR Spray has been placed in-service per FR-Z.I .
...........................................................................
-_______-____-_______ss_s_s_s___________-----------------------------------
Candidate:
Time Start:
NAME
Time Finish:
Performance Ratina: SAT -
UNSAT -
Performance Time -
COMMENTS
SIMULATOR OPERATOR INSTRUCTIONS:
I. Initialize to IC 466.
2.
Place Hold Order on A CS Pump
3.
Place simulator to RUN and acknowledge all alarms.
3.
Place simulator in FREEZE till performer has been briefed.
4. Place simulator to RUN after performer has been briefed
6.1 .f ROlSRO
Page 3 of 9
5. This JPM has been pre-shot in IC #166. Should IC #I66 be erased or fail to
perform as expected then use the following set-up instructions:
Initialize to IQO% BOL IC 50.
Insert irnf tho1 b 100 LOCA Hot Leg Loop 1 @ 100% .
insert irnf chOla 15 Cntmt Press Tx PDI 3-42 @ 15
Insert irnf ch01b 15 Cntntt Press Tx PDI 3-43 @ 15
Insert irnf chOlc 15 Cntmt Press Tx PBI 3-44 @ 15
Insert imf &Old 15 Cntmt Press Tx PDI 3-45 @ 25
STOP RCPS
Insert mrfsirl4 on (place power on 63-1).
Insert mrf csr04 off Select OFF (power to CS pump B).
Insert ior zaoei7212a 35 override value to 35 (CS pump B amps).
Insert ior zaofi7213 3000 override value to 3000 (CS pump B flow).
Insert ior zlohs7210a [3] override value to ON (CS pump 3 red light).
Insert isr zlohs7210a [1] override value to OFF (CS pump B light).
Insert ior zlohs7227a [=I]
override value to OFF (CS pump A light).
Insert ior zaotr726 106 override to 106 (CS Temp).
Insert ior zaopdi3042 12 override value to 12
Insert ior zaopdi3043 12 override value to 12
Insert ior zaopdi3044 12 override value to 12
Insert ior zaopdi3045 12 override value to 12
Insert ior zaopdi3045[1] 12 override value to 12
Insert lor zaopdi3045[2] 12 override value to 12
Insert ior zaopdr30133[1] 0.5 Cntmt Annulus AP
Insert ior zdihs72lOa ptlock (this helps simulate B CS pump on but is really off.
Perform appropriate procedures (E-0, ES-1.3) prior to placing RHR spray in service
Stop 1A-A CSP and Place in PTL and place hold order tag.
(through step 9 of Fa-Z.1).
SIMULATOR OPERATOR INSTRUCTIONS:
Step 6 of the JPM requires the following malfunction to be inserted when RHR Spray
valve 7-FCV-72-41 starts to OPEN:
irnf rho1 b to trip 1543 RHR pump
8.1 .f ROlSRO
Page 4 of 9
ToalslEquipmentlProcedures Needed:
Ensure clean copy of FR-Z.l in all copies of Functional Restoration Guidelines on the
Simulator FEOOF.
READ TO OPERATOR
DIRECTION TO TRAINEE:
I will explain the initial CoRditiORs, and state the task to be performed. All control
room steps shall be performed for this JPM, including any required
communications. I wili provide initiating cues and reports on other actions when
directed by you. Ensure you indicate to me when you understand your assigned
task. To indicate that you have compieted your assigned task return the handout
sheet I provided you.
INITIAL CONDITIONS:
The unit was at 100% when a Large Break LOCA occurred.
1A-A Containment Spray Pump has been tagged out of service.
15-5 Containment Spray Pump started and has been spraying Containment.
The break occurred an hour and 10 minutes ago.
All ECCS equipment is performing its design functions and is on Containment Sump
Recirc.
You are the Operator at the Controls (OAC).
INITIATING CUES:
The Unit Supervisor directs you to place RHR Spray in-service per FR-2.1 Step IO.
You are to notify the Unit Supervisor when RHR Spray is in service.
B.1 .f ROISRO
Page 5 of 9
START TIME:
STEP 1:
Obtain a copy of the procedure.
STANDARD: A copy of FIR-2.1 has been obtained.
COMMENTS:
STEP 2:
[Step I O ] DETERMINE if RHR Spray should be placed in
service:
a. CHECK the following conditions:
- At least one hour elapsed since beginning of the
accident.
- Cntmt Press greater than 9.5 psig.
- At least one charging pump and one SI pump
running.
-
RD: 1. Performer has determined that an hour has lapsel- since
the beginning of the accident. [Given in initial
conditions1
2. Cntmt press has been checked > 9.5 psig.
3. I-FCV-63-72 and 1-FCV-63-73 verified to be open by
red indicating lights.
4. 1 CCP & 1 SIP verified to be running by indicating lights
or amps.
COMMENTS:
STEP 3:
[STEP lob] ALIGN Train B RHR spray:
1) ENSURE Train B RHR pump RUNNING.
S T A N D I : Train B RHR pump verified to be running by indicating light
or amps.
COMMENTS:
-
-
UNSAT
-
-
UNSAT
-
-
UNSAT
B.l .f ROISRO
Page 6 of 4
STEP 4:
[STEP 10b 211 Close KHR crosstie 1-FCV-74-35.
STANDARD: 1-HS-74-35-A has been placedlchecked in the CLOSED
position and the green light illuminated on HS.
COMMENTS:
STEP 5:
[STEP 10b 3)] CLOSE RHR injection 1-FCV-63-94.
STANDARD: 1-HS-63-94-A has been placed in the CLOSED position
and the green light illuminated on WS. Step is crltical to
establish B Train RHR Spray.
COMMENTS:
STEP 6:
[STEP 10b 4)] OPEN RWR spray 1-FCV-72-41,
STANDARD: 1-HS-72-41A has been placed/checked in the OPEN
position and the Red light illuminated on HS. Step is
critical to establish B Train RHR Spray Flow.
COMMENTS:
CONSOLE OPERATOR NOTE: When FCV-72-41 STARTS OPEN in
the this step imf rhOlb to trip the 1B RHR pump. If asked to check
pump -state that it tripped on instantaneous QVW current.
EVALUATOR NOTE: Performer will acknowledge trip of 1B-B RHR
pump and place hand switch in pull-to-lock. Performer will either
have US dispatch personnel or will dispatch personnel to
investigate the trip of 1B-B RHR pump.
-
UNSAT
CRITICAL
STEP
-
-- UNSAP
CRITICAL
STEP
-
UNSAT
5.1 .f ROlSRO
Page 7 of 9
STEP 7:
[STEP 10b RNO] ALIGN Train A RHR spray:
I)
ENSURE Train A RHR pump RUNNING.
I
STANDARD: Train A RHR pump verified to be running by indicating light
or amps.
COMMENTS:
STEP 8:
[STEP 10b RNO] 2) CLOSE RHR crosstie 1-FCV-74-33.
STANDARD: 1-HS-74-33-A has been placedkhecked in the CLOSED
position and the green light illuminated on HS.
COMMENTS:
[STEP 10b RMO] 3) CLOSE RHR injection I-FCV-63-93.
STANDARD: 1-HS-63-93-14 has been placed in the CLOSED position
and the green light illuminated
HS. Step is critical to
establish A Train RHR Spray.
COMMENTS:
I
-
_il UNSAT
-
-
UNSAT
CRITICAL
STEP
-
-
UNSAT
B.1.f ROlSRO
Page 8 of 9
STEP I O :
[STEP 1Qb RNO] 4) OPEN RHR spray 1-FCV-72-40,
STANDARD: 1-HS-72-408 has been placedlchecked in the OPEN
position and the Red light illuminated on hand switch.
Step is critical to establish A Train RHR Spray.
COMMENTS:
STEP 11:
Notify the Unit Supervisor thaf RHR spray is in service.
STANDARD: Notify the Unit Supervisor that RHW spray has been placed
En service.
- CUE:
When notified, acknowledge the report using repeat
back.
COMMENTS:
END OF TASK
TIME STOP:
CRlTlCAL
STEP
I
-
-
UNSAT
APPLICANT CUE SHEET
(TO BE RETURNED PO EXAMINER UPON COMPLETlON OF TASK)
DIRECTION TO TRAINEE:
I will expiain the initial conditions, and state the task to be performed. All control
room steps shall be performed for this JPM, including any required
communications. I will provide initiating cues and reports on other actions when
directed by you. Ensure you indicate to me when you understand your assigned
task.
INITIAL CONDITIONS:
The unit was at 108% when a Large Break LOCA occurred.
1A-A Containment Spray Pump has been tagged out of service.
1 B-B Containment Spray Pump started and has been spraying Containment.
The break occurred an hour and 18 minutes ago
All ECCS equipment is performing its design functions and is on Containment Sump
Recirc.
You are the Operator at the Controls (OAC).
INITIATING CUES:
The Unit Supervisor directs you to place RHR Spray in-service per FR-Z.1 Step I O .
You are to notify the Unit Supervisor when RHR Spray is in service.
B.l .g ROiSRO
Page 1 of 18
REGION II
INITIAL LICENSE EXAMINATION
B.l =g ROlSRO JPMRB42A
Transfer RCP Board from Normal to Alternate per
sol-202.01
APPLICANT
EXAMINER
B.1.g ROlSRO
Page 2 of 10
REGION LI
INITIAL LICENSE EXAMINATION
T;rsk: Transfer RCP Board from Normal to Alternate per Sol-202.01
Alternate Path: NIA
Facility JPM #:
New
KIA Ratingls):
062A4.01 [3.3/3.1]
2.1.30 [3.9/3.4j
2 1.23 [4.8/3.4]
Task Standard:
The RCP 1A board is being fed from the Alternate Feeder (without an inadvertent
RCP trip) per Sol-282.01 Section 8.2.
Preferred Evaluation Location:
Simulator 2
In-Plant _s
Perform
X
Simulate -
References: Sol-202.04 "6.9 KV Reactor Coolant Board $A" Rev. 7
Task Number: RO-202-SOI-202-002
APPLICABLE FOR: KOISRO
Preferred Evaluation Method:
Examiner:
I
NAME
SIGNATURE
DATE
COMMENTS
SIMULATOR OPERATOR INSTRUCTIONS:
1
~
2. Place the Simulator in RUN
3. Acknowledge a16 alarms
Initialize to IC 175.
SIMULATOR OPERATOR INSTRUCTIONS:
NONE
B.1.g ROlSRO
Page 3 of 15
B.1.g RO/SRO
Page 4 of 10
ToolslEuuipmenffBrocedures Needed:
Ensure clean copy of SQI-202.01 in all copies of Operating Instructions on the
Simulator Floor.
READ TO OPERATOR
DIRECTION TO TRAINEE:
I will explain the initial conditions, and state the task to be performed. All control
room steps shall be performed for this JPM, including any required
communications. I will provide initiating cues and reports on other actions when
directed by you. Ensure you indicate to me when you understand your assigned
task. To indicate that YOU have completed your assigned task return the handout
sheet I provided you.
INITIAL CONDITIONS:
The Unit is in Mode 1 at 26% power.
RCP I
is being fed off its normal power source
You are the Operator At The Controls.
INITIATING CUES:
USER0 has directed you to transfer RCP 1 to its Alternate Supply per
Sol-202.01 and has granted approval to perform the task.
You are to notify the USlSRO when the transfer has been completed.
B.1.g ROlSRO
Page 5 of 10
START TIME:
STEP I:
EXAMINERS CUE: Affer the performer has demonstrated the mefhod of
obtaining the correct instruction, the evaluator can
provide a copy of the instruction.
Obtain a copy of the procedure.
STANDARD: A copy of Sol-202.01 has been obtained and performer has
turned to section 8.2.
I
COMMENTS:
STEP 2:
[Step $1 OBTAIN SRO approval
- CUE:
If asked, role play as Unit Supervisor and approve transfer
of 1A Unit Board from its normal supply to it alternate
supply.
STANDARD: Performer obtains SRO approval to perform task. (May
assume approval granted since directed by Unit Supervisor to
perform task.)
COMMENTS:
-
-
UNSAT
-
-
UNSAT
- Italicized Cues Are To Be Used Only !f JBM Performance Is Being Simulated-
STEP 3:
[STEP 21 CHECK voltage 6560 to 7260V lo Alternate ACB
on 1-1-57-112, START BUS AVOLTAGE iq-M-51.
STANDARD: I-El-57-1 12 has been checked and voltage verified to be within
the normal voltage range (6560 to 7260V).
COMMENTS:
STEP 4:
[STEP 31 ENSURE l-HS-68-8AA, RCP 1 NORMAL BKK &
LIFT PMP [1-M-5], PUSHED IN to place handswitch in control
ofACB 2112.
STANDARD: 1-HS-68-8AA has been placed in the IN position.
COMMENTS:
8.l.g ROlSRQ
Page 6 of 10
-
-
UNSAT
-
_I UNSAT
- italicized Cues Are To Be Used Only If JPM Performance Is Being Simulated.
B.1.g ROlSRO
Page 7 of 10
STEP 5:
[STEP 41 ENSURE I-HS-68-8BA, RCP I
ALTERNATE BKR
& XFER SELECTOR [I-M-5], PUSHED IN to place ACE 2522
auto transfer circuit in MANUAL.
STANDARD: 1-HS-68-8BA has been verified in the PUSHED IN position.
COMMENTS:
STEP 6:
[STEP 51 MONITOR 1-EI-68-8A, RCP I
AMPS [1-M-5] during
transfer to ensure RCP Amp load transfers to Alt supply.
STANDARD: The performer verifies that the amps on ?-Ef-57-8A rise during
the transfer in the following steps.
COMMENTS:
CAUTION
Release handswitches SLOWLY after transfer is complete to
prevent inadvertent breaker actuation.
STEP 7:
[STEP 61 PLACE I-HS-68-$BA, RCP 1 ALTERNATE BMW &
XFER SELECTOR, in START and HOLQ UNTIL transfer is
complete.
STANDARD: l-HS-68-8BA Hand switch is placed in the Start Position and
held in the Start Position.
Step is critical to assure prevent loss of bus during
performance of the next step.
COMMENTS:
-
__ UNSAT
-
__ UNSAT
CRITICAL
STEP
-
___ UN§AT
- italicized Cues Are To Be Used Only !f JPM Performance Is Being Simulated.
B.1 .g ROlSRO
Page 8 of 10
EVALUATOR NOTE: JPM Steps 8 and 9 evaluate procedure step
7.
STEP 8:
[STEP 71 PLACE I-HS-68-8AA, RCP 1 NORMAL 5KR &
LIFT PUMP, in STOP, and
STANDARD: 1-HS-68-8AA has been placed in the STOP position, then,
1-HS-68-8AA is released.
Step is critical to allow board transfer without
loss of bus or loads on the bus.
COMMENTS:
STEP 9:
[STEP 71 ENSURE Alt ACB 2522 CLOSED, and Normal
ACB 2? 12 OPEN.
STANDARD: 1.
Alternate Supply Bkr, 2522, red position indicating light
verified ON.
Normal Supply Bkr, 21 12, green position indicating light
verified ON.
2.
COMMENTS:
CRITICAL
STEP
-
-
UNSAT
- ffaficized
Cues Are To Be Used Only I f JPM Betformanee Is Being Simufated.
B.1.g HBlSRO
Page 9 of 10
STEP I O :
Notify Unit Supervisor that 6.9kV RCP Board I A has been
transferred to its alternate supply.
-
- CUE:
When notified, acknowledge the rsport using repeat
back.
STANDARD: The Unit Supervisor has been notified that 6.9kV RCP Board
la is on its alternate supply.
COMMENTS:
-
UNSAT
END OF TASK
/___
TIME STOP:
- !falicized Cues Are To Be Used only if JPM Betformance Is Being SimuMxf.
APPLICANT CUE SHEET
(TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)
DIRECTION TO TRAINEE:
I will explain the initial conditions, and state the task to be performed. All control
room steps shall be performed for this JPM, including any required
communications. I wilt provide initiating cues and reports on other actions when
directed by you. Ensure you indicate to me when you understand your assigned
task. Po indicate that you have completed your assigned task return the handout
sheet I provided you.
INITIAL CONDITIONS:
The Unit is in Mode 1 at 26% power.
RCP 1 is being fed off its normal power source.
You are the Operator At The Controls.
INITIATING CUES:
USlSRO has directed you to transfer RCP 4 to its Alternate Supply pes
SQI-202.04 and has granted approval to perform the task.
You are to notify the USlSRO when the transfer has been completed.
B.i.h RO
Page 1 of 14
REGION II
INITIAL. LICENSE EXAMINATION
B.1.h RO JPMR044
Alignment of the Upper Containment Monitor to the
Lower Containment from the MCR
APPLICANT
EXAMINER
B3.h RO
Page 2 of 14
Task:
Alternate Path:
F
=
)</A Ratinqk):
Task Standard:
REGION II
(NITIAL LICENSE EXAMINATION
JOBPERFORNlANCENlEASURE
EVALUATION SHEET
ALIGNMENT OF THE UPPER CONTAINMENT MONITOR TO THE
CONTAINMENT FROM THE MCR
3-OT-JPMR044 Rev 6
073K1.02 [3.613.9]
OWER
Perform alignment of the upper containment rad monitor to the lower containment compartment.
Candidate:
Time Start :
NAME
Time Finish:
Performance Ratincl: SAT
UNSAT
Performance Time
Examiner:
I
NAME
SIGNATURE
DATE
B.1.h RO
Page 3 of 14
SIMULATOR OPERATOR INSTRUCTIONS:
1. Initialize to IC 181
2. Acknowledge all alarms
2. NOTE: This JPM has been pre-shot in IC #18?. Should IC #181 be erased or fail to
perform as expected then use the following set-up instructions:
a. Reset simulator to 100% IC #(40, 50, or 60); then perform the following
b. Go to run, acknowledge alarms.
c. Close the following valves and ensure green indicating light is lit on 0-M-12.
1-HS-90-109
1-HS-90-108
1-HS-90-109
1-HS-90-110
1-HS-90-1 I 1
The above will cause W173E to Alarm which is expected for the conditions.
d. Set up e l trigger for use in 4PM Step 6 by entering the following:
ior an:ov:06c087 (el) alarm
ior zlolrm90112c[3] (el) off
e. View simulator over ride summary to ensure that the above over rides have been
assigned to e l trigger.
f. Freeze simulator.
g. Place simulator in run when directed by the examiner
NOTE TO CONSOLE OPERATOR: This JPM requires the use of triggersloverrides which
must be inserted at the appropriate times (Performance Steps 5,8 and 9) to have
annunciator alarms or monitor lights that reflect operations that the candidate will request N O
to start/ stop radiation monitor sample pumpslreset iodine bow flow alarm locally.
B.4.h 80
Page 4 of 14
TooBs(EcluipmenffProc~du~es
Needed:
Ensure enough copies of Sol-90.02; GASEOUS PKOCESS RaDlATlON MONITORS
are available in the Simulator file cabinet, since Operators will obtain their own copy of the
procedure.
READ TO OPERATOR
DIRECTION TO TRAINEE:
B will explain the initial conditions, and state the task to be performed. All control
room steps shall be performed for this JPM, including any required
communications. I will provide initiating cues and reports on other actions when
directed by you. Ensure you indicate to me when you understand your assigned
task. To indicate that you have completed your assigned task return the handout
sheet I provided you.
INITIAL CONDITIONS:
You are the Unit 1 CRO.
Unit I
is at 100% power.
1 -RM-90-106 has been removed from service for maintenance per appropriate
procedure.
INITIATING CUES:
The Unit Supervisor has requested you to align the upper containment rad monitor
to lower containment per proper procedure. You are to notify the Unit Supervisor
when the alignment is complete.
B.7.h RO
Page 5 of 14
START TIME:
STEP 1:
Obtain a copy of the appropriate procedure.
STANDARD: Operator obtains a copy of S0%-30.02; GASEOUS
PROCESS RADIATION MONITORS Section 8.1.
COMMENTS:
NOTE Bf any Radiation Monitor experiences sufficient elevated reading
above normal request MIG to perform purge.
NOTE Chemistry shouid be notified to address compensatory measures
for any radiation monitor required operable per Tech Specs/BDCM,
which is being removed from service.
Role play as Chem Lab, acknowledge request to address cornp
measures since 1-RM-90-112 will not be aligned to upper
containment.
CUE:
STEP 2:
[I]
ENSURE Upper Containment Air Monitor Aligned per
Section 5.2.
STANDARD: Operator determines that the Upper Containment Air Monitor
is aligned per procedure.
Inform the operator that the upper containment air
monitor is aligned for normal operation per SO!-90.
02, Section 5.2.
CUE:
COMMENTS:
-
-
UNSAT
-
-
UNSAT
B.1.h RO
Page 6 of 14
STEP 3:
121 NQTlFY Chem lab of intent to realign monitors so that
proper sampling of Cntmt. and release permits are
addressed.
STANDARD: Operator notifies the Chem lab of intent to realign monitors
so that proper sampling of Cntmt. and release permits are
addressed.
Using repeat back, acknowledge the message.
CUE:
COMMENTS:
NQTE If 1-RM-90-112 is aligned in place of 1-RM-90-106, it is inoperable
during a lower containment purge until the alarm setpoints are
recalibrated.
STEP 4: [3] DEPRESS the TOGGLE MONITOR pushbutton on the ICS
PURGE computer screen AND ENSURE SPXLO96,
Radiation Monitor in Use, displays 1-RM-90-112.
STANDARD: Operator enters PURGE using any ICS key board, then
using mouse, selects push button TOGGLE MONITOR
106/112. Operator then verifies that computer point
SPXL096 RADIATION MONITOR IN USE is displaying 90-
112.
COMMENTS:
-
U N SAT
~
-
UNSAP
STEP 5: [4J CONTACT MIG to determine the appropriate value for ICs
point SPXR035, 1-RM-90-112B Bias, for setpoint
calculation and update SPXR095 in the ICs.
STANDARD: Operator contacts MIG and to determine Bias value to use
for IC§ point SPXR095.
CUE:
Role play as ME, acknowledge request, then state that bias
value must be calculated for 1-RM-90-112B. When the bias
value has been calculated, an Instrument Mechanic will adjust
value in ICs and notify the Unit Supervisor.
COMMENTS:
STEP 6: [5] SHUTDOWN Lower Containment Air Monitor per Section 7.2.
STANDARD: Operator determines that the Lower Containment Air Monitor
has already been removed from service per initial conditions.
CUE: If asked, inform the operator that the lower containment air
monitor has been removed from service.
COMMENTS:
B.1.h RO
Page 7 of 14
__ SAT
-
UNSAT
-
-
UNSAT
B.l.h RO
Page 8 of 14
STEP 7: [6]
ENSURE 1-RE-90-106 and 1-RE-90-112 pumps are OFF
before aligning monitor. The following handswitches control
power to the sample pumps [A3Uff37 on top of monitor
enclosure]:
I-HS-90-106A
1-HS-90-106B
- 1-HS-90-112A
I-HS-90-1126
STANDARD: Operator contacts the Aux. Building AUO to ensure I-RE-90-
106 and 1-RE-90-112 pumps are OFF before aligning
monitor.
CONSOLE OPERATOR: Roll play as AUO, Acknowledge request, then
activate e l trigger by: imf itrigger, then contact
the candidate and give him/her the following cue:
CUE:
Inform the operator that both 1-RE-90-106 and 1-RE-90-
112 pumps are OFF and that 1-PMP90-112A was the
running pump.
COMMENTS:
STEP 8: [S]
RECORD the monitor sample pump STOPPED (N/A pump
NOT stopped):
[a] I
-HS-90-112A
[b] 1-HS-90-112B.
STANDARD: Operator records the monitor sample pump STOPPED and
N/As pump NOT stopped 1-HS-90-112B.
If asked, 1-PMP-90-112A was the running pump.
CUE:
COMMENTS:
-
-
UNSAT
I
-
UNSAT
E.1.h RO
Page 9 of 14
STEP 9:
[a] PERFORM the following:
NOMENCLATURE
-0WER CONTAINMENT
SUP TO 1-RE-SO-I12
)ROSS TIE
2NTMT TO RM-106 CIV-
)VI INSIDE CNTMT
ZNTMT TO RM-1QG CIV-
- VI
OUTSIDE CNTMT
ZNTMT TO RM-112 CIV-
CVI OUTSIDE CNTMT
ZNTMT TO RM-112 CIV-
CVI INSIDE CNTMT
CNTMT TO RM-112 CIV-
CVI INSIDE CNTMT
CNTMT TO RM-112 CIV-
CVI INSIDE CNTMT
CNTMT TO RM-I 12 CIV.
STANDARD: Operator contacts the Aux. Building AUO and directs the
AUO to open I-ISIV-90-112A. The operator then places the
rad monitors containment isolation valves in the correct
configuration as per this check list and verifies position by
valve indicating lights.
NOTE: Rad monitoring will be inadequate if this valve
Lineup not done properly.
CUE:
When asked as AUQ, acknowledge request, then state that 1-
ISIV-90-112A is now OPEN.
COMMENTS:
CRITICAL
STEP
-
-
UNSAT
B.1.h RO
Page 10 of 14
STEP 10: [9]
START the monitor sample pump STOPPED in Step [7]
(N/A pump NOT started):
[a]
1-HS-90-I12A
[b]
1-HS-90-1128
STANDARD: Operator contacts the Aux Building AUO and directs the
AUO to start I-PMP-90-1128. Operator determines that step
[9] [b] is N/A. Rad monitoring will be inadequate if pump
is not started.
CONSOLE OPERATOR: Roll play as AUO, Acknowledge request. then
insert override: ior an:ov:05C087 off to set
W173E clear, then contact the candidate and
give himlher the following cue:
CUE: As AUO when contacted, inform the operator that 1-PMP-90-
112A has been started.
COMMENTS:
CRITICAL
STEP
-
-
UNSAT
B.1.h RO
Page II of 14
STEP 11: [IO] IF IODINE LOW FLOW ALARM on skid comes in, THEN
RESET with 1-HS-90-2 12JB.
STANDARD:
Operator informs the Aux Building N O to reset the lODiNE
LOW FLOW ALARM on the skid with I-HS-90-112JB, if in
alarm.
CONSOLE OPERATOR: Roll play as AUQ, Acknowledge request, then
modify override: zlo?rm90112~[3] on to turn
green operate light on for the iodine monitor and
give himlher the following cue:
CUE: When contacted as the AUO, acknowledge request using repeat
back, then inform the operator that the IODINE LOW FLOW is in
ALARM.
CUE: When asked to RESET alarm as AUO, then acknowledge
request (modify the over ride above), then state the alarm has
been reset.
COMMENTS:
-
-
U N SAT
B.1.h RQ
Page 12 of 14
STEP 12: 6111 PERFORM Monitor Source Check [O-M-l2], and
- NSURE 1-RM-90-112 (A, B & C) green OPERATE
Lights LIT and red HIGH &yellow ALEKT Lights NOT
LIT.
ENSURE ANN 173-A UPR CNTMP AIR 1-RM-I 12 RAD
HI, NOT LIT.
ENSURE ANN 273-D UQR CNTMTAIR 1-RM-112
INSTR MALF, NOT LIT.
STANDARD: Operators performs a monitor source check and ensures that
1-RM-90-112
(A, B&C) green OPERATE bights are LIT and
red HIGH & yellow ALERT Lights NOT LIT.
ENSURES ANN 173-8 UPK CNTMTAIK 1-RM-112 RBB and til
and ANN 173-D UPR CNTMT AIR 1-RM-112 INSTR MALF
NOT LIT.
COMMENTS:
STEP 13:
[I21
ENSURE Local Panel Lights RESET
STANDARD: Directs the AUO, to ensure local panel lights are reset.
CUE: When contact as the AUO, inform the operator that t4e local
panel lights are reset.
COMMENTS:
-
I
UNSAT
-
UNSAT
B.1.h RO
Page 13 of 14
STEP 14:
IF the alarm setpoint values for 1-RM-90-112
were
changed in step [4] [due to purging lower
containment], return the alarm setpoint values to
normal WHEN the purge is secured.
STANDARD: Operator determines step is not applicable at this time.
COMMENTS:
STEP 15:
Notifies Unit Supervisor that Upper Cntmt monitor
has been aligned to lower Cntmt per SOI-90.02
Section 8.4. States that bias will be adjusted by
MIG when they have completed their calculation of
the bias value.
STANDARD: Unit Supervisor has been notified that Upper Cntmt monitor
has been aligned to lower Cntmt. And that the bias will be
adjusted later by MIG.
CUE:
COMMENTS:
When notified, acknowledge report using repeat back.
END OF TASK
TIME STOP:
-
-
UNSAT
__ SAT
-
UNSAT
APPLICANT CUE SHEET
(TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)
DIRECTION TO TRAINEE:
I will explain the initial conditions, and state the task to be performed. All control
room steps shall be performed for this JPM, including any required
communications. I will provide initiating cues and reports on other actions when
directed by you. Ensure you indicate to me when you understand your assigned
task. Bo indicate that you Rave completed your assigned task return the handout
sheet I provided you.
INITIAL CONDITIONS:
You are the Unit 1 CRO.
Unit 1 is at 100% power.
1-RM-90-106 has been removed from sewice for maintenance per appropriate
procedure.
INITIATING CUES:
The Unit Supervisor has requested ysu to align the upper containment rad monitor
to lower containment per proper procedure. You are to notify the Unit Supervisor
when the alignment is complete.
B.2.a /Local
Page Z of 10
REGION II
INITIAL LICENSE EXAMINATION
B.2.a JPMA024/Local
Isolate the RCP Seal Injection and Thermal Barrier
per ECA-0.0
APPLICANT
EXAMINER
B.2.a /Local
Page 2 of I O
REGION II
INITIAL LICENSE EXAMINATION
Task: isolate The RCP Seal Injection And Thermal Barrier Per ECA-O.0
Alternate Path: N/A
Facilitv JPM #:
KIA Rating(sl:
855-EK3.02 [4.3/4.6]
004-Kl.04 [3.4/3.8]
2.1.30 [3.9/3.4]
Task Standard:
Preferred Evaluation Location:
Preferred Evaluation Method:
Simulator-
In-Plant X
Perform
Simulate
References: ECA-0.0 "boss of Shutdown Power" Rev.18
Task Number:: AUO-113-ECA-0.0-001
APPLICABLE FOR: AUOIROISRO
3-OT-JPMA024 Rev 6
The valves listed in Appendix " A of ECA-0.0 have been located and closed
RO-113-ECA-0.0-001
10CFR55.45: 6, 8, 9, 10
Validation Time: 22 rnin. Time Critical: No
...........................................................................
_______________________s_ss_ssss________-----------------------------------
Candidate:
Time Start:
NAME
Time Finish:
Perfsmance Rating: §AT -
UNSAT -
Performance Time -
Examiner:
NAME
!
SIGNATURE
BATE
COMMENTS
B.2.a /Local
Page 3 of 10
-
Toelsl~uuiprnentlPracedures Needed:
Hard Hat, Safety Glasses, Hearing Protection, and Plant Approved Shoes.
ECA-0.0 Appendix A
ALARA considerations, BIT room.
NOTE:
EVALUATOR NOTE:
Provide copy of ECA-0.0 Attachment A to performer with
candidates cue sheet
READ TO OPERATOR
DIRECTION TO TRAINEE:
I will explain the initial conditions, and state the task to be performed. At1 control
room steps shall be performed for this JPM, including any required
communications. I will provide initiating cues and reports on other actions when
directed by you. Ensure you indicate to me when you understand your assigned
task. To indicate that you have completed your assigned task return the handout
sheet 1 provided you.
INITIAL. CONDITIONS:
The unit has just entered Mode 3 following a shutdown required by Tech. Specs due to
the Boss of 6.9kV Shutdown Board 1 B-B.
The B CVCS Seal Injection Water Filter is in service.
A tornado on site caused a complete loss of Off-Site power and the ?A-A Diesel
Generator failed to start.
The crew transitioned to ECA-0.0 due to the loss of shutdown power and is progressing
through the steps.
Attempts are being made to restore shutdown power.
You are an AUO on shift.
INITIATING CUES:
The CRO has directed you to perform Appendix A of ECA 0.0 to isolate the RCB
seals and thermal barrier.
You are to notify the CRO when you have finished Appendix A.
8.2.a Local
Page 4 of 10
START TIME:
STEP 7 :
Obtain a copy of Appendix A of ECA-0.0.
STANDARD: A copy of the Appendix A of ECA-0.0 has been obtained.
EXAMINERS CUE: Provide copy of Appendix A of ECA-Q.0 to
performer.
COMMENTS:
Note: These steps can be performed in amy order. (Steps 2- 9)
STEP 2:
[Step I] ISOLATE RCP seal return valves [reach rods
outside filter cubicle]:
CLOSE 1-ISV-62-642, CVCS SEAL WBR RETURN
FILTER INLET ISQL [A5T/713].
STANDARD: 1-ISV-62-642 has been located and turned clockwise to
close. Step is critical to isolate flow path from RCP
seals to VCT.
- CUE:
After the performer demonstrates how to close valve,
state that the hand wheel turns several turns and
stops.
COMMENTS:
__ §AT
___ UNSAT
CRITICAL
STEP
-
-
UNSAT
- Italicized Cues Are To Be Used Only If JPM Performance !s Being Simukted.
B.2.a /Local
Page 5 of 10
STEP 3:
[STEP 1 continued] 9
CLOSE 2-BW-62-643, CVCS
SEAL WTR RETURN FILTER BYPASS [A5Tnl3].
STANDARD: 1-BW-62-643 has been located and checked closed.
- CUE:
After the performer demonstrates how to check valve
closed, state that the hand wheel does not turn when
clockwise motion is applied.
COMMENTS:
STEP 4:
[STEP 21 ISOLATE RCP seal injection [reach rods
outside seal water injection filter cubicles]:
CLOSE I-ISV-62-549, CVCS SEAL WTR INJ FLTW
E3 OUT !SOL [A5T/713].
STANDARD: 1-8SV-62-549 has been located and turned clockwise to
close. Step is critical because it isolates the flow path
from CVCS to RCP seals preventing thermal shock to
shaft and seal if CVCS charging is restored.
- CUE: After the performer demonstrates how to close
valve, state that the hand wheel turns several turns
and stops.
COMMENTS:
-
-
UNSAT
CRITICAL
STEP
-
UNSAT
- Italicized Cues Are To Be Used Only if JPM Petforaance is Being Simulated.
B.2.a /Local
Page 6 of 10
STANDARD:
- CUE:
STEP 5:
[STEP 2 continued] * CLOSE 1-BW-62-546, CVCS
SEAL WTR BNJ FLTR BYP [MT/713].
-BW-62-546 has been located and checked closed.
After the performer demonstrates how to check
valve closed, state that the hand wheel does not turn
when clockwise motion is applied.
COMMENTS:
STEP 6:
[STEP 2 continued]
CLOSE 1-ISV-62-550, CVCS
SEAL WTR INJ FLTR A OUT ISOL [A5T/713].
STANBARD: 1 -ISV-62-550 has been located and checked closed.
After the performer demonstrates how to check
valve closed, state that the hand wheel does not turn
when clockwise motion is applied.
- CUE:
COMMENTS:
I__ SAT
-
UNSAT
-
~
UNSAT
- /falicked Cues Are To Be Ysed Only If JPM BerFormance Is Being Simulated.
B.2.a Local
Page 7 of 10
NOTE TO EVACUATQR: CUE: Stop performer before entering
BIT room (for ALARA concerns) and have candidate describe
valve location (valve 1-FCV-70-90). Use posted survey map.
After candidate describes the valves approximate location.
Simulate the performance of the next step without entering the
BIT Room.
STEP 7:
[STEP 31 ISOLATE RCP thermal barrier:
CLOSE I-FCV-70-90, THERMAL BARRIER CCS
RETURN [above south side of BIT].
STANDARD: 1 -FCV-70-90 has been located, actuator engaged and
turned clockwise to close. This step is critical to isolate
flow pat4 to protect CCS from steam formation in
CCS.
EXAMINER NOTE: This valve is in the BIT room, overhead just
below the ceiling in the southwest corner behind the
BIT. ALARA considerations. If candidate attempts to
climb up to valve without first checking with RADCON,
stop candidate and require contact with RADCON. See
note preceding this step.
- CUE: After the performer demonstrates how to close
valve, state that the hand wheel turns many turns
and stops.
COMMENTS:
CRiTlCAb
STEP
__ SAT
- italicized Cues Are To Be Used Only I f JPM Performance Is Being Simwiated.
B.2.a /Local
Page 8 of 10
STEP 8:
[STEP 3 continued]
CLOSE l-ISV-70-677A, CCS
THRM BAR BSTR PUMP ?A-A DlSCH ISOCATION
[A5W/737].
STANDARD: 1-ISV-70-677A has been located and turned clockwise to
close. Step is critical to isolate flow path to prevent
thermal shock to RCP seals when CCS is restored.
- CUE
After the performer demonstrates how to close
valve, state that the hand wheel turns many turns
and stops.
COMMENTS:
STEP 9:
[STEP 3 continued]
CLOSE l-!SV-70-6773, CCS
THRM BAR BSTR PUMP I
B-B DlSCH ISOLATION
[A5W/737].
STANDARD: l-ISV-70-677B has been located and turned clockwise to
close. Step is critical to isolate flow path to prevent
thermal shock to RCP seals when CCS is restored.
After the performer demonstrates how to close
valve, state that the hand wheel turns many turns
and stops.
- CUE:
COMMENTS:
CRITICAL
STEP
-
-
UNSAT
CRITICAL
STEP
-
-
UNSAP
- /falicized Cues Are To Be Used Ody If JPM Performance Is Being Simulated.
STEP I O :
Inform the Control Koorn Operator that Appendix A of
ECA-0.0 has been completed.
STANDAKD: The control room operator has been informed that the
Appendix A has been completed.
- CUE:
When notified, acknowledge the report using repeat
back.
COMMENTS:
END OF TASK
TIM STOP:
B.2.a /Local
Page 9 Qf 10
-
-
UNSAT
- Italicized Cues Are TO Be Used Only If JPM Performance Is Being Simulated.
CANDIDATE CUE SHEET
(TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)
DIRECTION TO TRAINEE:
I will explain the initial conditions, and state the task to be performed. All control
room steps shall be performed for this JPM, including any required
communications. I will provide initiating cues and reports on other actions when
directed by you. Ensure you indicate to me when you understand your assigned
task. To indicate that you have completed your assigned task return the handout
sheet B provided you.
INITIAL CONDITIQNS:
The unit has just entered Mode 3 following a shutdown required by Tech. Specs due to
the loss of 6.9kV Shutdown Board IB-8.
The "B" CVCS Seal Injection Water Filter is in service.
A tornado on site caused a complete loss of Off-Site power and the 1A-A Diesel
Generator failed to start.
The crew transitioned to ECA-0.0 due to the loss of shutdown power and is progressing
through the steps.
Attempts are being made to restore shutdown power.
You are an AUO on shift.
INlTlATlNG CUES:
The CRO has directed you to perform Appendix "A" of ECA 0.0 to isolate the RCP
seals and thermal barrier.
You are to notify the CRO when you have finished Appendix A.
B.2.b /Local
Page 1 of 7
REGION II
INITIAL LICENSE EXAMINATION
B.2.b JPMA034/Local
Reset the TDAFW Pump (after mechanical
overspeed) per SOI-3.02
APPLICANT
EXAMINER
B.2.b /Local
Page 2 of 7
REGION II
INITIAL LICENSE EXAMINATION
JOB PERFORMANCE MASURE
Bask: Reset The TSAFW Pump (After Mechanical Overspeed) Per 501-3.02
Alternate Path: NIB
Facility JPM #:
3-OT-JPMA034 Rev 6
K/A Ratinds):
061-K4.07 [3.1/3.3]
2.1.30 [3.9/3.4]
Task Standard:
The Turbine-Driven AFW pump Trip and Throttle (TT) valve has been reset as
indicated by the trip lever remaining in the engaged position.
Candidate:
Time Start:
Time Finish:
NAME
Performance Rating: SAT __ UNSAT
~
Performance Time -
COMMENTS
Ei.2.b /bacai
Page 3 of 7
PoolslEuuipmen~Broced~res
Needed:
Hard Hat, Safety Glasses, Hearing Protection, Gloves and Plant Approved Shoes.
Sol-3.02 (Latest Revision)
Safety Considerations: Keep away from rotating parts during JPM performance (Pump
has auto start)
NOTE:
JPM to be started at the Radwaste AUO Desk.
READ TO OPERATOR
DIRECTION TO TRAINEE:
I will explain the initial conditions, and state the task to be performed. All control
room steps shall be performed for this JPM, including any 'required
communications. I will provide initiating cues and reports on other actions when
directed by you. Ensure you indicate to me when you understand your assigned
task. To indicate that you have completed your assigned task return the handout
sheet I provided you.
INITIAL CONDITIONS:
A Reactor Trip has occurred from 100 % power.
The Turbine-Driven AFW pump has tripped on mechanical overspeed.
The MCW Operator informs you of the AFW pump turbine trip and that he ran the motor
in the closed direction for 30 seconds.
You are the Aux Building AUO.
INITIATING CUES:
The MCR operator directs you to locally check the Trip and Throttle (T and T)
valve in the proper position to be reset and then reset the Turbine-Driven AFW
pump Trip and Throttie valve.
You are to notify the MCR operator after the valve has been reset so that the MCR
alarm may be reset.
B.2.b /Local
Page 4 of 7
START TIME:
STEP I:
Obtain a copy of the procedure.
STANDARD: A copy of Sol-3.02 Section 8.3 has been obtained.
EXAMINERS CUE: After the performer has demonstrated the
method of obtaining the correct instruction, the
evaluator can provide a copy of the instruction.
COMMENTS:
NOTE: The following steps are the steps in Section 8.3.
NOTE 1
Following an Overspeed Trip, the I-HS-46-56!3, TB AFW PMP
TRIP/THV 1-FCV-1-51 PQS CNTL, local limit lights will show valve
CLOSED.
NOTE 2
FIGURE 1 provides additional information for local operation
STEP 2:
[STEP 4 1 IF a Mechanical Overspeed Trip occurred,
THEN RELATCH the Mechanical Overspeed Trip Device
locally.
STANDARD: The connecting rod has been placed in the reset position
(moved towards the T&T valve) by Pulling the reset
connecting rod towards the trip and throttle valve till
movement stops. Step is critical to reset mechanical
Overspeed trip mechanism.
- CUE: If asked, before linkage is reset, state that the trip
lever is down, and the valve stem pieces are not
meshed.
- CUE:
If asked, afler performer demonstrates proper
method to reset trip device, then state the trip lever
remains in the engaged position but the valve stem
pieces are meshed.
COMMENTS:
-
-
UNSAT
CRITICAL
STEP
-
sl_ UNSAT
- Italicized Cues Are To Be Used Only I f JPlM Performance Is Being Simulated.
B.2.b /Local
Page 5 of 7
STEP 3:
[STEP 21 IF in the MCR, THEN PLACE 1-HS-46-56A-S,
T-D AFWP T&T VLV, in CLOSE, and HOLD for 30
seconds to latch 1-FCV-1-51 motor drive to the valve
stem.
STANDARD: Performer N/As step based upon task assignment initial
conditions and proceeds to next step.
COMMENTS:
~
UNSAT
STEP 4:
[STEP 3 1 IF local [A3T/692], THEN
[a] PLACE 1-XS-46-57, TB AFW PMP CONTROLS
TRANSFER SWITCH to AUX. [behind CCS Seal
leakage tank]
FCV-1-51 POS CNTL, TO CLOSE, and HOLD for 30
seconds to latch 1-FCV-1-51 motor drive to the valve
stem.
[b] DEPRESS 1-HS-46-56B, TD AFW PMP TRIP/THV 1-
STANDARD: Perkmer N/As step based upon task assignment initial
conditions.
I
COMMENTS:
-
-
UNSAP
- italicized Cues Are To Be Used Only If JPM Performance Is Being Simulated.
STEP 5:
[STEP 41 IF Turbine will not be restarted immediately,
THEN ENSURE motor drive is latched to valve stem
(IQcaliy).
STANDARD: Performer verifies that motor drive is latched to valve
stem.
- CUE: I f valve checked; the valve stem pieces are meshed
COMMENTS:
STEP 6:
NOTIFY Unit Operator that Turbine Driven AFW pump Trip
& Throttle Valve has been reset.
STANDARD: The MGR operator has been notified that Turbine Driven
AFW pump Trip & Throttle Valve has been reset.
- CUE:
When notified, acknowledge the report using repeat
back
COMMENTS:
END OF TASK
TIME STOP:
B.2.b /Local
Page 0 of 7
-
-
UNSAT
-
-
UNSAT
- italicized Cues Are To Be Used Only If JPM Performance Is Being Simulated.
CANDIDATE CUE SHEET
(TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)
DIRECTION TO TRAINEE:
I will explain the initial conditions, and state the task to be performed. All control
room steps shall be performed for this JPM, including any required
communications. I will provide initiating cues and reports on other actions when
directed by you. Ensure you indicate to me when you understand your assigned
task. To indicate that you have completed your assigned task return the handout
sheet I provided you.
INITIAL CONDITIONS:
A Reactor Trip has occurred from 100 % power.
The Turbine-Briven AFW pump has tripped on mechanical overspeed.
The MCW Operator informs you of the AFW pump turbine trip and that he ran the motor
in the closed direction for 40 seconds.
You are the Aux Building AUO.
INITIATING CUES:
The NlCR operator directs you to locally check the Trip and Throttle (T and T)
valve in the proper position to be reset and then reset the Turbine-Driven AFW
pump Trip and Throttle valve.
You are to notify the MCR operator after the valve has been reset so that the MCR
alarm may be reset.
B.2.c Local
Page 1 of 22
REGION II
INITIAL LICENSE EXAMINATION
B.2.c JPMAOOl B/Local
Perform local restart of Control and Service Air
Compressors per AOI-10
APPLICANT
EXAMINER
B.2.c /Local
Page 2 of 12
REGION II
INITIAL LICENSE EXAMINATION
Perform local restart of Control and Service Air Compressors per AOI-10.
Alternate Path: Compressor "A has high discharge air temperature and high oil
indication lights. Compressor "a" fails to auto load.
3-OT-JPMA001B Rev 3
FaciliW JPM #:
- atur
K/A Ratinds):
878-A3.01 [3.1/3.2]
065-AK3.08 [3.7/3.9] 065-AA2.08 [2.9/3.3]
2.1.20 [4.2/4.2]
2.1.30[3.1/3.2]
Task Standard: "A" and "B" Air Compressors have been aligned and started per AOI-10. Control Air
(Non-Essential) pressure has been re-established.
Preferred Evaluation Location:
Simulator -
References: 801-10 "Loss of Control Air" Rev. 27
Task Number:: AUO-032-AOI-010-002
APPLICABLE FOR: AUO/RB/SRB
Preferred Evaluation Method:
In-Plant
X
Perform
Simulate
X
RO-032-801-10-002
10CFR55.45: 3, 4, 6, 8
Validation Time:
10
min.
Time Critical: No
s--____s_______________------_----------------------------
_____________-------_________sss_ssss___-----------------------------------
Candidate:
Time Start:
NAME
Time Finish:
Performance Rating: SAT -
UNSAT _s
Performance Time -
COMMENTS
8.2.c /Local
Page 3 of 12
ToolslEcluipmentl8rocedures Needed:
Hard Hat, Safety Glasses, Hearing Protection, Gloves and Plant Approved Shoes.
AOI-10 Attachment 1
High Noise Area. Energized rotating equipment that can auto start.
NOTE:
EVALUATOR NOTE: Provide a copy of AOI-IO Attachment 1 to perfolrmer with
candidate's cue sheet.
READ TO QPERATQR
DIRECTION TO TRAINEE:
I will explain the initial conditions, and state the task to be performed All control
room steps shall be performed for this JPM, including any required
communications. I will provide initiating cues and reports on other actions when
directed by you. Ensure you indicate to me when you understand your assigned
task. To indicate that you have completed your assigned task return the handout
sheet I provided you.
INITIAL CONDITIONS:
A Station Blackout has occurred resulting in a reactor trip.
The DGs have started and are feeding the SD Bds.
The Control and Service Air compressors were aligned normal with "C" air compressor
in the lead prior to the BlackouVtrip.
A loss of Non-essential and Service air has occurred (Air pressure is at 75 psig
drop p ing ) .
Essential Air is being supplied by the Aux. Air cornpressors
The 480V Aux Bldg Common Bd does not have voltage available on its normal or alt
Local control power is available to the air compressors (no alarm in MCR).
You are a support AUQ on shift
supply.
INITIATING CUES:
The MCR operator has dispatched you with a copy of Attachment 1 of AOl-10 with
instructions to perform steps 2 through 'IO.
Notify the MCR operator when the task is complete.
B.2.c /Local
Page 4 of 12
START TIME:
STEP 1:
Obtain a copy of the procedure.
STANDARD: A copy of AOI-IO, Attachment 1 ha5 been obtained.
EXAMINERS CUE Provide copy of AOI-10 Attachment 1 to
performer.
COMMENTS:
STEP 2:
[Step 21 Localiy CHECK 0-PCV-33-4, SERVICE AIR
SUPPLY [SOLATION, CLOSED [T7M/708].
STANDARD: 0-PCV-33-4 has been checked in the closed position by
either the green local indicating light or the stem down on
the valve.
- CUE:
When the valve is checked, state fiat green light
QN, Red right OFF, Stem down, indication at C
COMMENTS:
-
-
UNSAT
-
__ UNSAT
- Italicized Cues Are To Be Used Only !f JPM Performance Is Being Simulated.
B.2.c Local
Page 5 of 12
STEP 3:
[STEP 31 CHECK local station alarm DARK [ Panel O-L-
240, T7M/708]
STANDARD: Local Station (Panel 0-b-24Q) Alarms have been checked
and Operator proceeds to RNO column due to high
discharge air temp and high oil temp on A compressor.
Step is critical because A cornpressor would have
trip logic still set with switch not reset locally.
- CUE:
When checked, state that Compressor A has a
high discharge air temp and high oil temp light
illuminated.
COMMENTS:
STEP 4:
[STEP 3 RNO a] IF local control station alarm LIT, THEN
PERFORM the following for each air cornpressor in alarm:
a.
RESET high air temp at each compressor (0-TS-32-
4T, -36, -31).
STANDARD: The High Air Temp reset push button, 0-TS-32-41, (on
west side of A air compressor) has been depressed.
Step is critical because A compressor cannot be
started with the alarm switch NOT reset.
- CUE:
When checked, and after candidate indicates how to
depress pushbutton for 0-TS-32-41
state it is as you
see it (reseq.
COMMENTS:
CRITICAL
STEP
-
-
L A T
CRITLCAL
STEP
I__ SAT
-
UNSAT
- ltaiicized Cues Are To Be Used Only E f JPM Performance Is Being Simulated.
B.2.c Local
Page 6 of 12
STEP 5:
[STEP 3 RNO b] RESET high oil temp at each air
compressor (0-TS-32-40, -35, -30).
STANDARD: The High oil Temp reset push button, 0-TS-32-40, (on
east side of A air cumpressor) has been depressed.
Step is critical because A compressor cannot be
started with the alarm switch NOT reset.
- CUE:
COMMENTS:
When checked, and affer candidate indicates how to
depress pushbuffon for 0-TS-32-40 state it is as you
see it reset.
STEP 6:
[STEP 3 RNO c] RESET cummon alarm using C-HS-32-
233: COMPRESSOR A, B, C RESET [0-L-24< yellow
PB].
STANDARD: 0-HS-32-233 has been pushed. Step is critical because
A compressor cannot be started without using
pushbutton to reset trip logic.
COMMENTS:
CRlTlCAL
STEP
-
CRITICAL
STEP
-
- ltaficired Cues Are To Be Used Only If JBM Performance Is Being Simulated.
B.2.c /Local
Page 7 of 12
STEP 7:
[STEP 3 RNO d] CHECK common and all local alarms,
DARK.
STANDARD: All alarms on panel have been checked dark.
- CUE:
After high air temp and high oil temp. reset push
buttons at compressor
and 0-HS-32-256 has
been pushed, inform performer that all alarms
lights on panel are dark.
COMMENTS:
STEP 8:
[STEP 41 PLACE the following C&SS Compressors to
WAND [Q-L-240]:
A, 0-HS-32-25D.
B, Q-HS-32-26A.
STANDARD: 0-HS-32-25B for A Compressor and 0-HS-32-26A for
B Compressor have been placed to the HAND position.
Step is critical because the hand switches enable the
respective local start pushbuttons.
- CUE:
COMMENTS:
Both handswitches point to HAND.
-
-
UNSAT
CRITICAL
STEP
-
-
UNSAT
- /talicized Cues Are TO Be Used Only If JPM Performance Is Being Simulated.
B.2.c /Local
Page 8 of 12
STEP 9:
[STEP 51 PLACE 0-HS-32-25A1 STATION AIR
COMPRESSOR SEQUENCE CONTROL, to Position I.
STANDARD: 0-HS-32-25A, Station Air Compressor Sequence Selector
Control, has been placed in Position 1.
- CUE:
State that Sequence Selector indicates position 3
before operation and fhen state position 1 affer
operation.
COMMENTS:
STEP I O :
[STEP 61 START Air Compressor A by pushing 0-HS- 32-25E.
'STANDARD: 0-HS-32-25E manual start push button is depressed
Step is critical to start air compressor.
- CUE:
I f JPM Steps 4,5, 6, and 8 were SAT, then when PB
is depressed, if asked, state that a air cornpressor
sfart was heard. If JPM Steps 4, 5, 6, or 8 were
UNSAT, if asked, state that compressor staart was
not heard.
COMMENT'S:
___ SAT
-
UNSAT
CRITICAL
STEP
-
-
UNSAT
- italicized Cues Are To Be Used Onry If JPM Performance Is Being Simulated.
B.2.c /Local
Page 9 of 12
STEP 11:
[STEP 73 CHECK Compressor A loads automatically.
STANDARD: It has been determined that air compressor "A" is NOT
loaded. Operator proceeds to RNO coiumn due to failure
of "A" compressor to load.
When checked, state that the air compressor sound
indicates that it has NOT loaded, state that air
pressure is NOT rising (several /oca/ gauges), or, if
both solenoids are checked to be magnetized, state
that they are de-energized.
- CUE
COMMENTS:
STEP 12:
[STEP 7 RNO] IF Compressor A does not Auto load,
THEN PLACE 0-HS-32-43A and -435 to ON (Local O-JB-
291-226).
STANDARD: 0-HS-32-438 and 0-HS-42-43B have been placed to the
ON positions and it has been deteimined that air
compressor "Ai has loaded. Step is critical to ensure
solenoids energized to allow "A" air compressor to
load.
- CUE: Affer hand switches have been placed to the ON
position and when checked, state that the air
compressor sound indicates that it has loaded, the
air pressure is rising, or, if both so/ensids are
checked to be magnefized, state that they are
energized.
COMMENTS:
-
___ UNSAT
CRlTICAL
STEP
-
UNSAT
- Italicized Cues Are To Be Used Only I f JPM Performance is Being Simulated.
B.2.c /Locai
Page 10 of 12
STEP 13:
[STEP 7 RNO] IF Compressor A does not load from
local panel THEN:
a. CLOSE 0-ISV-32-578, STATION AIR COMPR A
UNLQADING HEIR ISOL.
UNLOADING HBR TEST.
b. VENT 0-TV-32-579, STATION AIR COMPR A
STANDARD: Performer determines that cornpressor has loaded
(previous step) and moves to the next step.
COMMENTS:
STEP 14:
[STEP 81 START Compressor B by pushing 0-HS-32-
268.
STANDARD: 0-HS-32-26B manual start push button is depressed
Step Is critical to start air compressor.
- CUE:
If JPM Step 8 was SAP, then when PB is depressed,
if asked state that a air compressor sfasp was
heard. If JPM Steps 8 were UNSAT, if asked, state
that compressor starf was not heard.
COMMENTS:
STEP 15:
[STEP 91 CHECK Compressor B loads automatically.
STANDARD: It has been determined that air compressor "B" is fully
loaded.
- CUE:
When checked, state that the air compressor sound
indicates that it has loaded or, if both solenoids are
checked to be magnetized, state that they are
energized.
COMMENTS:
-
__ UNSAT
CRITICAL
STEP
-
-
UNSAT
-
-
UNSAT
- italicized Cues Are To Be Used Only 15 JPM Performance Is Being Simuiated.
5.2.c /Local
Page 11 of 12
STEP 16:
STANDARD:
[STEP 101 MONITOR Air Compressor operation.
Compressors auto loading.
Qil Pressure 25-30 psig on A, B, and C.
Cooling water flow.
Oil pressure is checked on both compressors to be 25-30
psig. (A. 0-PI-32-40 & B. 0-PI-32-35)
Cooling water is verified by observing discharge drains.
Compressors are checked for full load operation.
Operator determines that Compressor A will have to be
manuaily loaded and unloaded to maintain greater
then 80 psig.
NOTE: C Air Compressor is shutdown due to loss of
power
- CUE:
Affer each parameter is checked, inform the
Performer that each compressor has 28 psi$ oil
pressure, the coolhng water fiow is normal and the
compressors are ful!y loaded.
EXAMINERS CUE: When operator determines that Compressor
A will have to be manually kwdedlunioaded
then terminate JBM by stating Well stop
here.
COMMENTS:
END OF TASK
TIME STOP:
- Italicized Cues Are To Be Used Ody FJPM Performance Is Being Simulated.
CANDIDATE CUE SHEET
(TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)
DIRECTION TO TRAINEE:
I vdl explain the initial conditions, and state the task to be performed. All control
room steps shall be performed for this JPM: including any required
communications. I will provide initiating cues and reports on other actions when
directed by you. Ensure you indicate to me when you understand your assigned
task. To indicate that you have completed your assigned task return the handout
sheet I provided you.
lNlTlAL CONDITIONS:
A Station Blackout has occurred resulting in a reactor trip.
The DGs have started and are feeding the SB Bds.
The Control and Service Air compressors were aligned normal with "C" air compressor
in the lead prior to the Blackoutltrip.
A loss of Non-essential and Service air has occurred (Air pressure is at 75 psig
dropping).
Essential Air is being supplied by the Aux. Air compressors.
The 48QV Aux Bldg Common Bd does not have voltage available on its normal or alt
supply.
Local control power is available to the air compressors (no alarm in MCR).
You are a support AUO on shift
INITfATING CUES:
The MCR operator has dispatched you with a COPY of Attachment 1 of AOI-10 with
instructions to perform steps 2 through I O .
Notify the MCR operator when the task is complete.