George Vanderheyden 1650 Calvert Cliffs Parkway Vice President Lusby, Maryland 20657 Calvert Cliffs Nuclear Power Plant 410.495.4455 Constellation Generation Group, LLC 410.495.3500 Fax I Constellation Energy August 4, 2004 U. S. Nuclear Regulatory Commission Washington, DC 20555 ATTENTION: Document Control Desk

SUBJECT:

Calvert Cliffs Nuclear Power Plant Unit No. 1; Docket No. 50-317 Inservice Inspection Report Please find enclosed the Inservice Inspection Report for the Calvert Cliffs Nuclear Power Plant Unit 1.

This inspection fulfilled the intentions and requirements stated in our program plan and our commitment to comply with American Society of Mechanical Engineers Code Section XI Inservice Inspection Requirements.

Should you have questions regarding this matter, we will be pleased to discuss them with you.

Very trul our GV/CAN/bjd

Enclosures:

(1) Calvert Cliffs Nuclear Power Plant, Inservice Inspection Summary Report for Calvert Cliffs Unit 1, ASME Boiler & Pressure Vessel Code Section XI, Form NIS-1 (2) Calvert Cliffs Nuclear Power Plant, Inservice Inspection Summary Report for Calvert Cliffs Unit 1, ASME Boiler & Pressure Vessel Code Section XI, Form NIS-2 cc: Mr. Craig Lowry (Without Enclosures)

J. Petro, Esquire H. J. Miller, NRC kc7 J. E. Silberg, Esquire Resident Inspector, NRC Director, Project Directorate I-1, NRC R. V. Guzman, NRC R. I. McLean, DNR 04

ENCLOSURE (1)

CALVERT CLIFFS NUCLEAR POWER PLANT, INSERVICE INSPECTION

SUMMARY

REPORT FOR CALVERT CLIFFS UNIT 1 ASME BOILER & PRESSURE VESSEL CODE SECTION XI, FORM NIS-1 Calvert Cliffs Nuclear Power Plant, Inc.

August 4, 2004

Page I of 2 NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS (As required by the Provisions of the ASME Code Rules) 1.Owner Constellation Energy, P.O. Box 1475, Baltimore, MD 21203 (Name and Address of Owner)

2. Plant Calvert Cliffs Nuclear Power Plant, 1650 Calvert Cliffs Parkway, Lusby, MD 20657 (Name and Address of Plant)
3. Plant Unit 1
4. Owner Certificate of Authorization (if required) N/A
5. Commercial Service Date 05/0 811975
6. National Board Number for Unit 209111
7. Components Inspected Component or Manufacturer or Manufacturer or Installer State or National Board No.

Appurtenance Installer Serial No. Province No.

Reactor Pressure Vessel Combustion Engineering CE-67107 14000NV 20911 Pressurizer Combustion Engineering CE-67602 14000NV 20915 Steam Generator #11 Combustion Engineering CE-67504 14000NV 20922 Steam Generator #12 Combustion Engineering CE-67505 14000NV 20923 Reactor Coolant Piping Combustion Engineering N/A N/A N/A Safety Injection Bechtel N/A N/A N/A Pioinv/Suvoorts Pressurizer Spray Bechtel N/A I N/A N/A Pivinw/Suooorts I Pressurizer Safety &Relief Bechtel N/A N/A N/A Pioine/Suovorts l Shutdown Cooling Bechtel N/A N/A N/A Pinine/Suioorts l Main Steam Bechtel N/A N/A NIA Pioine/Sunnorts l Feedwater Piping/Supports Bechtel N/A N/A N/A Charging Piping/Supports Bechtel N/A N/A N/A Letdown Piping Supports Bechtel N/A N/A N/A Containment Spray Bechtel N/A N/A NIA PioinelSumoorts i

8. Examination Dates 6/19/2002 to 7/20/2004
9. Inspection Period Identification: 2002 to 2006
10. Inspection Interval Identification: 1999 to 2009
11. Applicable Edition of Section XI 1998 Addenda None
12. Date/Revision of Inspection Plan: CCNPP Units I & 2 Third Interval ISI Plan, Revision 0

NIS-1 rage OL x

13. Abstract ofExaminations and Tests. Include a list of examinations and tests and a statement concerning status of work required for the Inspection Plan.

The examinations reported herein constitute the sixteenth report of Inservice Inspections performed at Calvert Cliffs Unit 1, and the first report within the second inspection period of the third Inspection interval during commercial operation. The examinations for this inspection period, as required by the Third Interval Plan for Calvert Cliffs Units I& 2, were performed In accordance with the 1998 Edition of ASME Code Section Xl with No Addenda. In addition to the Section Xl required examinations we performed baremetal visual examinations of all of the Unit 1 dissimilar metal butt welds containing Ahloy 82/182 material which operate at hot leg and pressurizer temperatures in accordance with the EPRI MRP recommendations.

We also performed baremetal visual and volumetric examinations of the reactor vessel closure head in accordance with the revised NRC Order EA-03-009. See Attachment I for a list of Class 1 and 2 components examined. Nondestructive examination data and procedures are available at the plant site for review.

14. Abstract of Results of Examinations and Tests.

Surface examination of feedwater support 16-FW-1218-R3 integral attachment revealed an indication which exceeded the acceptance criteria of IWC-3512. Supplemental volumetric examinations In accordance with IWC-3512(c) verified the indication was acceptable and the depth of the indication was verified to be less than 1/32" by physical removal of the indication. Examinations of the dissimilar metal butt welds and the reactor vessel closure head were found to be acceptable with no indications of leakage.

15. Abstract of Corrective Measures.

Supplemental examinations of feedwater support 16-FW-1218-R3 found the surface Indication to be acceptable.

We certify that a) the statements made in this report are correct, b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI, and c) corrective measures taken conform to the rules of the ASME Code,Section XI.

Certificate of Authorization No. ( if applicable) N/A Expiration Date 3/

0A Date 07/21/2004 Signed Constellation Energy By m5 f r 1 Owner 9T* IY%tff'AVA/

CERTIFICATE OF INSERVICE INSPECTION L,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectores and the State or provinces of Maryland and employed by ABS Consulting of Houston, TX have inspected the components described in this Owner's Report during the peroid 6/2012002 to 7/20/2004 , and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in this Owners Report in accordance with the inspection plan and as required by the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes and any warranty, expressed or implied, concerning the examinations, tests, and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Doff-4 A.- sH4P/ 4 Fot extra1z 0q&5 i) ~ d3 pat efg Commissions A 74a; N, Is /US M ii/o National Board, State, Province, and Endorsements Date Q I TiULY a,06' N 6 17775 } / 13S

-- -- I --

Pae of 1 - 10 Attachment I Inservice Inspectlon Report Owner Constellation Energy, P.O. Box 1475. Baltimore, MD 21203 Owner Certifcate of Authorization (If Req.): NIA Plant: Calvert Cliffs Nuclear Power Plant, 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Commercial Service Date: 05/08/1975 Plant Unit: 1 National Board Number for Unit 20911 Summary No. Comp ID t1.4- it- 0 .... .A.- M4fhitAhUR" sUe C-#.- MMn M.-l C.-. f.*-

..v -. -Y ...... - .... 1.

cIA 1 003625 ICI BOLTING 1-64 ICI BOLTING 1-64 B-G-2 B7.10 NDE-5712-C VT CCO44V-182 Accept 064 A-I 57r2004 Commenr: No caUIns rnoed.

003es0 2-401D LOWER SHELL ATODEG. B-B 92.12 NDE-5419-CC UT CC04-IU-018 Accept 064 4/22004 Conments: NO RECORDABLE INDICATIONS NOTED 004000 3-401 LOWER SHELL TO LOWER HEAD B-B B2.11 NDE-5419-CC UT CC04-lU-017 Accept 064 4J22/2004 NDE-5419-CC UT CCO44U-031 Accept 064 4/27/2004 Commefts: ID GEOMETRY INDICATIONS WERE NOTED 004050 4-404 NOZZLE TO HEAD WELDS B-0 93.110 NDE-5419-CC UT CCo4-IU-014 Accept 064 4/0/004 Comments: WILL CONSIDER SUBMIT'ING RELIEF REQUEST FOR THIS WELD BASED ON LIMITED UT COVERAGE 004250 4-404 IRS NOZZLE INSIDE RADIUS SECTION B-D B3.120 NDE-5417-CC UT CC04-IU-032 Accept 064 4/21/2004 NO RECORDABLE INDICATIONS NOTED 004550 MANWAY STUDSINUTS 1-20 MANWAY STUDS 1-20 B9--1 B7.20 NDE-5712-CC VT CCo44V-005 Accept 064 U-1 A-4 411042004 Conmf: No evIdence o boric acddfound 005750 OUTLET SIDE MANWAY STUDSINUTS OUTLET SIDE MANWAY STUDSINUTS - - NDE-5712-CC VT CCO44V-01 I Accept 064 U-1 A-4 4/11r2004 Comment: No cwable hndcaft noted 005850 INLET SIDE MANWAY STUDSrNUTS INLET SIDE MANWAY STUDSrNuTS - - NDE-5712-CC VT CC044V-012 Accept 064 U-1 A-5 4/11/2004 Comments: No rmccrdble kIdlcallo noled 007050 OUTLET SIDE MANWAY STUDSrNUTS OUTLET SIDE MANWAY STUDSNUTS - - NDE-s712.CC VT CCO44V-013 Accept 064 U-I A-S 4/11I2004 Comments: No Recordable Indications noted.

007150 INLET SIDE MANWAY STUDSrNUTS INLET SIDE MANWAY STUDSrNuTS - - NDE-8712-CC VT CC044V-014 Accept 064 U-1 A-4 4/11/2004 Comments: No recordable indications noted.

104550 30-RC-IiB-7 ELBOWTOSAFE END R-A R1.20 NDE-5710-CC VT CC04-IV-010 Accept 064 120344004.4008 4/13/2004 Conts: No leakage noted.

107600 30-RC-12A -10 SAFE END TO PIPE R-A R1.20 NDE-5710-CC VT CCo4-lV-016 Accept 064 12034-004 4008 4/15/2004 Comments: No leakage noted 110450 12-PSL-1 NOZZLETOSAFEEND R-A RI11 NDE-5710-CC VT CCo4-IV-0I8 Accept 064 80798,120244009 4/11r2004 Comments: No leakage noted 110850 12-PSL-6 ELBOWTOPIPE R-A RI11 NDE-5412-CC UT CC044U-002 Accept 064 60798,12024-0009 4/27/2004 Comments: NO RECORDABLE INDICATiONS NOTED 110900 12-PSL-9 PIPETOELBOW R-A R1.11 NDE-5412-CC UT CC04-IU-02S Accept 064 60796, 120244009 4/27/2004 Comnrnts: INDICATIONS WERE INTERMITTENT 360 DEGREES AROUND WELD 111100 12-PSL-13(star) NOZZLE TO SAFE END R-A Ri11 NDE-6710-CC VT CCO4-IV.009 Accept 064 6079s,1202440009 4/132004 Conmnenft: No bleake noted

Page of 2 - 10 Attachment I InservIce Inspection Report Owner. Constellation Energy, P.O. Box 1475. Baltimore, MD 21203 Owner Certificate of Authorization (HfReq.): N/A Plant Calvert Cliffs Nuclear Power Plant, 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Commercial Service Date: 0510811975 Plant UnIt: 1 National Board Number for Unit 20911 Summary No. 0 Comp ID Comp Desc. Categor! Item Procedure ~

tUtothnot/Rhoot/F7ot Ite

.mfml Ip v , v o u is Cuctom

. y @ c ,, Ila^

  • J%

M...-

lu, . .- c , n%-&-

C-n . a 113150 12-SC-1004 - 1(star) NOZZLE TO SAFE END R-A R1.20 NDE-5710-CC VT CCO44V-08 Accept 052 91101,9114U 4/10/204 Comments: No leakage noted 114350 12-SI-1009 -16 SAFE END TO NOZZLE R-A R1.20 NDE-5710-CC VT CC044-v021 Accept 052 91100 414/2004 Comments: no leakage noted 115000 12-SI-1011 -13 NOZZLE TO SAFE END R-A R1.20 NDE-5710-CC VT CCO44V-017 Accept 052 91100SH0003 4/15/2004 Comments: No leakage noted 118300 4-PS-1003-2 TEETOELBOW R-A R1.11 NDE-5412-CC UT CC04-IU-029 Accept 084 91099SH0002 412712004 Comments: ID ROOT GEOMETRY WILL CONSIDER THIS WELD FOR REUEF REQUEST BASED ON LIMITED COVERAGE 118500 4-PS-1003 -t NOZZLE TO SAFE END R-A R1.11 NDE-5710-CC VT CC044V-004 Accept 064 91099SH-t002 4/10/2004 Comm~ents: No widicatlons noted 123100 4-SR-1005 -1 NOZZLE TO SAFE END R-A R1.11 NDE-5710-CC VT CC04V-022 Accept 064 91098SH0002 411/2004 Commernts: No leakage noted 123450 4-SR-100W- 1 NOZZLE TO SAFE END R-A R1.11 NDE-5710-CC VT CC04V-023 Accept 064 91098SHOOOI0 418/r2004 Comments: No leakage noted 124210 2.5-SR-1004 - 2A PIPE TO PIPE R-A B9.21 NDE-5210-CC PT CC04-IP-01 I Accept 0t4 91098SHOOOI 4/23/2004 Comments: This was a presevce examisnatIon the orlgral report was filed wit the MO package.

126300 2-CV.1003- 13 PIPE TO PIPE R-A R1.20 NDE-5412-CC UT CC04-IU-030 Accept 041 FSK-MP-490 v=004 Coniments: NO RECORDABLE INDICATIONS NOTED 129750 2-CV-1005 - 17 ELBOW TO PIPE R-A R1.20 NDE-5412-CC UITCCO44-.1-012 Accept 041 FSK-MP-492 4V17/2004 Canments: WILL CONSIDER FOR RELIEF REQUEST SUBMITAL DUE TO LIMITED COVERAGE 12l800 2-CV-1005 - 18 ELBOW TO PIPE R-A R1.20 NDE4412.CC UT CCO44IU.013 Accept 041 FSK(-MP-492 4117/2004 Commrents: NO RECORDABLE INDICATIONS NOTED 129950 2-CV-1005 - 21 PIPE TO PIPE R-A R1.20 NDE-5412-CC UT CC04-IU-033 Accept 041 FSK-MP-492 4/17/2004 Comments: Root geometry seen intermittently 380 degrees at loe amplitudes.

130000 2-CV-1005 - 22 PIPE TO PIPE R-A R1.20 NDE-5412-CC LT CC04"U-035 Accept 041 FSK-MP-492 4117/2004 Commants: ROOT GEOMETRY INDICATIONS NOTED 130450 2-CV-1005 -29 NOZZLE TO SAFE END R-A R1.11 NDE-6710-CC VT CC044IV.020 Accept 041 FSK-MP-492 4114/2004 Comnts: No leakage noted 131250 2-DR-1003 -1A SAFE END TO PIPE R-A R1.20 NDE-5412-CC UT CC044U-036 Accept 064 FSK-MP-575, -5i5H 411/204 Comments: NO RECORDABLE INDICATIONS NOTED 131500 2-DR-1004-1 NOZZLE TO SAFE END DRAIN LINES R-A R1.20 NDE-5710-CC VT CCO4-r008 AcCept 084 FSK-MP"1053. .053H 4112/2004 Comnts: No leakage noted 132150 2-DR-1 008

  • 1 NOZZLE TO SAFE END DRAIN LINES R-A R1.20 NDE-4710-CC VT CCo4-4V-019 Accept 064 FSK-MP-1006, -lOO0GH- 4114V2004 Comments: No leakage noted

Page of 3 - 10 Attachment I Inservice Inspection Report Owner Constellation Energy, P.O. Box 1475, Baltimore, MD 21203 Owner Certificate of Authorization (HfReq.): N/A Plant: Calvert Cliffs Nuclear Power Plant, 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Commercial Service Date: 05/08/1975 Plant Unit: 1 National Board Number for Unit: 20911 C ---,,o V *UI f. - ~In r-~nn rfl- Categ or Iem Procedure -

Method/Sheet/Results System ISO Num Exam Date 132450 2-DR-1007 - NOZZLE TO SAFE END DRAIN LINES R-A R1.20 NDE-5710-CC VT CCO44V-07 Accept 064 FSK-MP-507 4/12/2004 Comments: No leakage noted 133200 11A-1 INTEGRAL ATTACHMENT RCP-I IA B-K 810.30 NDE-210-CC PT CC04-IP-020 Accept 064 A-33 4/22/2004 Comments: NO RECORDABLE INDICATIONS NOTED 133250 11A-2 INTEGRAL ATTACHMENT RCP-1 1A B-K B10.30 NDE-5210-CC PT CCU4-IP.021 Accept 064 A-33 4/22/2004 Conaents: NO RECORDABLE INDICATIONS NOTED 133500 11A-C-I THROUGH 1e RCP-1 1A SEAL BOLTING B--2 87.60 NDE-5712-CC VT CC04-IV-OfO Accept 064 4Rn2004 Comments: No recodble indications noted 134050 118-C-1 THROUGH 16 RCP-118 SEAL BOLTING B--2 87.60 NDE-5712-CC VT CCO4-IV-081 Accept 064 4/27/004 Comments: No recordable indications noted 134600 12A-C-1 THROUGH 16 RCP-12A SEAL BOLTING B--2 B7.60 NDE-5712-CC VT CC044V-04 Accept 064 4/27/2004 Commns: No recordable indications noted 135150 128C01 THROUGH 16 RCP-12B SEAL BOLTING B--2 B7.60 NDE-5712-CC VT CC04-IV-3 Accept 064 Comments: No ecordble IIdtions noted I-CV-100F1I PRESSURIZER SPRAY VALVE LOWER B-M-i 812.30 NDE-5210.CC PT CC04-IP-002 Accept 064 91099SHOO02 4/27/2004 135235 Comments: No recordable ndiations noted.

1-CV-100F-2 PRESSURIZER SPRAY VALVE UPPER B-M-I 812.30 NDE-210-CC PT CC04-IP-003 Accept 064 91099SHOO02 4/27/2004 135240 Comments: No recordable Indications noted.

136150 1-MOV-614 ON 12-S-1009 VALVE BODY BOLTING B--2 87.70 NDE-s712-CC VT CCU4-IV-038 Accept 052 91100 4/15/2004 Commvenls: No material loss. No signs d Boric Abd 1-MOV-424 ON 12-S1010 VALVE BODY BOLTING W-0-2 87.70 NDE-5712-CC VT CCo4-V-039 Accept 052 91100SH10002 4/15/2004 136200 Comments: No recordable indications noted 136250 1-MOV-634ON 12-SI-1011 VALVE BODY BOLTING B--2 87.70 NDE-5712-CC VT CCO4-IV-040 Accept 052 91100SHOD03 4/15/2004 Comments: No recdable Indications noted 136300 1-MOV-644 ON 12-S11012 VALVE BODY BOLTING B-0-2 B7.70 NDE-571 2-CC VT CC04-lV-031 Accept 052 91 100SHOO04 4/20/04 Commnts: No recordable indications noted 136450 1-MOV-403 ON 2.5-SR-1003 VALVE BODY BOLTING B-0-2 87.70 NDE-5712-CC VT CCO44V-030 Accept 064 91098SH0002 4/27/2004 Commns: No recordable indications noted.

136500 1-MOV-405 ON 2.5-SR-1004 VALVE BODY BOLTING B-0-2 B7.70 NDE-5712-CC VT CCU4V-065 Accept 064 91093SHooo1 4/2712004 Comments: No recordable Indication noted 136550 I-CV-517 ON 2-CV-1003 VALVE BODY BOLTING B--2 87.70 NDE-5712-CC VT CC04-IV-034 Accept 041 FSK-MP-490 Co aments: No recordable indictions noted 136600 1-CVC-3ss ON 2-CV-1003 VALVE BOOY BOLTING B-0-2 87.70 NDE-5712-CC VT CCU44V-033 Accept 041 FSK-MP-490 4/20/2004 Comments: No bolting on this valve.

136650 1-CVC-165 ON 2-CV-1003 VALVE BODY BOLTING B--2 B7.70 NDE-4712-CC VT CCO-V-032 Accept 041 FSK-MP-490 4/2ot20014 Comments: There was no bdlti assocated wift gim

Page of 4 -10 Attachment I Inservice Inspection Report Owner Constellation Energy, P.O. Box 1475, Baltimore, MD 21203 Owner Certificate of Authorizatlon (If Req.): N/A Plant: Calvert Cliffs Nuclear Power Plant, 1650 Calvert Cliffs Parkway. Lusby, MD 20657 Commercial Seovtce Date: 05/08/1975 Plant Unit: 1 National Board Number for Unit: 20911

'1mmdC

.e. txrs

'u.

Immns rmnI vum* ,u *F r..

n.

wwVU.C. Categorw item Procedure Ijathk,.AIh910a

-. 11lOIRI1B7X:

1-il[ -. -

.4.

.1II Otlatam

-7li .....

IMC

.l V Mt,,n, I=am fat.

13M850 1-CVC-392 ON 2-CV-1005 VALVE BODY BOLTING B-G-2 87.70 NDE-5712-CC VT CC04-4V-088 Accept 041 FSK-MP-492 4/15/2004 Comments: No valve bolting on tis valve.

137100 1-CV-515 ON 2-1004 VALVE BODY BOLTING B4--2 B7.70 NDE-5712-CC VT CC04-IV458 Accept 041 FSK-MP-455. -458 4/27/2004 Comments: No recordable dications noted 137200 1-CV-516 ON 2LD-1I002 VALVE BOGY BOLTING B-G-2 B7.70 NDE-5712-CC VT CCO44V-059 Accept 041 FSK-MP-455, -456 412712004 Comments: No recodble Indcatiors noted 137250 1-CV-518 ON 2-CV-1004 VALVE BODY BOLTING B-C-2 B7.70 NDE-5712-CC VT CC04-IV-041 Accept 041 FSK-MP-401 4/15r2004 Coaments: No recordable indications noted 137300 1-CV-519 ON 2-CV-1005 VALVE BODY BOLTING B-G-2 B7.70 NDE-5712-CC VT CC04-IV-042 Accept 041 FSK-MP-492 4/1512004 Comments: No recordable InlIcatons noted 13785O 1-1-217 ON 12-SI-1009 VALVE BODY BOLTING B4--2 87.70 NDE-5712-CC VT CCO44V-078 Accept 052 91100 4/2012004 Comments: No reco ble ndications noted 137700 1-SI-227 ON 12-SI-1010 VALVE BODY BOLTING B-G-2 B7.70 NDE-5712-CC VT CC04-V-079 Accept 052 91100SHO002 412012004 Conts: No rewbdb indictin noted 137750 141-247 ON 12-S1-1012 VALVE BODY BOLTING B-G-2 B7.70 NOE-5712-CC VT CCO44V-080 Accept 052 91`1008HC0004 4/27/2004 Comments: No recordable indications noted.

137800 141-237 ON 12-S1-1011 VALVE BODY BOLTING B-0-2 07.70 NDE-5712-CC VT CC04V-081 Accept 052 911005H0003 4/27/2004 Commentt: No redable Indlicatons noted 137t)0 1-MOV-651 ON 14-SC-1004 VALVE BODY BOLTING BG-2 87.70 NDE-5712-CC VT 2004BV028 Accept 052 91101.91148 3/1/2004 Coments: No Indications noted.

137900 1-MOVW- ON 12-SC-1004 VALVE BODY BOLTING 8-G-2 87.70 NDE-4712-CC VT CCO44-V82 A-t 052 91101.91146 4/27/2004 Conts: No recordable indications noted 137950 11-5-118 ON 8-81-1001 VALVE BODY BOLTING BG-2 B7.70 NDE-5712-CC VT CC04-IV-043 Accept 052 91100 4/1512004 Comments: No recordable Indications noted 138000 141-128 ON "81-1002 VALVE BODY BOLTING B-4-2 87.70 NDE-5712-CC VT CC044V-089 Accept 052 91 1005t10002 4/15/2004 Comments: Sliht cornelon. no materdal Ioss noted 138050 1-41-138 ON t-S1-1003 VALVE BOGY BOLTING B4--2 B7.70 NOE-5712-CC VT CC04-IV-070 Accept 052 911008110003 4/1152004 comments: No recordable Indications noted 138100 1-51-148 ON 8-51-1004 VALVE BODY BOLTING B-0-2 B7.70 NDE-5712-CC VT CC044V-038 Accept 052 911005H0004 4/202004 Comments: No recordable Indications noted 138630 2.5-SR-1007 - 2FB INLET FLANGE BOLTING B4--2 87.50 NDE-5712-CC VT CC044V-87 Accept 084 910985H0002 4/27/2004 Comments: No recoable IdctIons noted 138840 2.5-SR-1008 - 2FB INLET FLANGE BOLTING B--2 B7.50 NDE-5712-CC VT CC044V-088 Accept 084 91098SHOI01 4/2712004 Cots: No indications noted

Page of 5-10 Attachment I Inservice Inspection Report Owner Constellation Energy, P.O. Box 1475, Baltimore, MD 21203 Owner Certificate of Authorization (f Req.): N/A Plant: Calvert Cliffs Nuclear Power Plant. 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Commerclal Service Date: 05108/1975 Plant Unit: I National Board Number for Unit: 20911 Summary No. Comp ID Comp Desc. Catlegon kRem Procedure PVIUL IuonUIvWQUS C.Ctm

Jfl~m AC0 Mi,. ..

l-I rc-S.0.,

n.f ualJ

=

138650 PRESSURE RETAINING COMPONENT REACTOR PRESSURE VESSEL B-P B15. 10 NDE-5710-CC VT CC04-IV-164 Acce-t 06A 8072SHO1OO Y712004 Commns: No Indications noted 138750 PRESSURE RETAINING COMPONENT PRESSURIZER B-P 615.20 NDE-5710-CC VT CC044V-165 Accept 064 607295HO001 57/2004 Co Tfens: No IndlcatIons noted.

138850 PRESSURE RETAINING COMPONENT STEAM GENERATORS B-P B15.30 NDE-5710-CC VT CCO44IV-166 Accept 064 80729SHo1OO Y7/2004 Commnts: No Indications noted.

1389!0 PRESSURE RETAINING COMPONENT HEAT EXCHANGERS B-P B15.40 NDE-4710-CC VT CC044V-167 Accept 064 607295H0001 57/2004 Conf No IrndIatIons noted.

60729sHooo1/ 60730 139050 PRESSURE RETAINING COMPONENT PIPING B-P B15.50 NDE-5710-CC VT CC044V-168 Accept 064 052 041 60731 57/2004 Conms: No Indications node.

139150 PRESSURE RETAINING COMPONENT PUMPS B-P B15.60 NDE-5710-CC VT CC04-1V-169 Accept 064 607295H0001 5/7/2004 Cons: No indIcations noted.

139250 PRESSURE RETAINING COMPONENT VALVES B-P B15.70 NDE-5710-CC VT CC04-IV-170 Accept 052 041 60730 & 60731 5/7/2004 Convnrt Minor packg leakage noted on several valves corecled on fte spot under IR4 -95.

600250 12-PSL - H-1 COMPONENT SUPPORT F-A FIOC NDE-5711-CC VT CCO4-4V-050 Accept 064 12024-9 REV 11 4/23/2004 Comrents: No .lcorabe Indications eos550 3-PS-1001 - H-12 COMPONENT SUPPORT F-A FI.IA NDE-5711-CC VT CCO4-V-04 2 Accept 064 910995H0001. SH0002 40/2004 Cornffs: NO RECORDABLE INDICATIONS NOTED 605350 2-L-l1004 - R-4 (144-35) COMPONENT SUPPORT-SNUBBER F-A F1.10C NDE-5711-CC VT CCo4-4V-180 Accept 041 FSK-MP-455, -456 4/19/2004 Comment: No recordable Inicatons noted 605400 2-LD-1004 (1-64-31) COMPONENT SUPPORT-SNUBBER F-A FIOC NDE-5711-CC VT CC04-IV-181 Accept 041 FSK-MP-455, -456 4/19/2004 Comments: No recordable indicatom noted.

605600 2-CV-1003 - H-28, R-32 CONPONENT SUPPORT F-A F1.10B NDE-4711-CC VT CC04-IV-057 Accept 041 FSK-MP-490 427/2004 Comnna: NO RECORDABLE INDICATIONS NOTED 605650 2-CV-1003 - H-27, R-33 CONPONENT SUPPORT F-A F1.108 NDE-5711-CC VT CC04-4V-05 Accept 041 FSK-MP-490 471274004 Comma: NO RECORDABLE INDICATIONS 2-CV-1005 - R-13, R-14 COMPONENT SUPPORT F-A F1.108 NDE-5711-CC VT CC04-NV-027 Accept 041 FSK-MP-492 51/2004 Conrsef: No relevant conditions noted.

806850 2-CV-1005 - R-17 COMPONENT SUPPORT F-A F1.10B NDE-5711-CC VT C004V-l18S Accept 041 FSK-MP-492 511/2004 NDE-571 1-CC VT CC04-NV426 Info 041 FSK-MP-492 4/22a2004 Convients: Examination folIlowrg bed removal revealed no recorable Indications.

606700 2-CV-1005 - R-15, R-18, H-12 COMPONENT SUPPORT-SNUBBER F-A Fi1OC NDE-5711-CC VT CC04-V-184 Accept 041 FSK-MP-492 5/1/2004 NDE-571 1-CC VT CCO44V-025 Info 041 FSK-MP-492 416/2004 Comma: ExamInation foalng beadremoval revealed no recordable Idications.

Page of 6 -10 Attachment I Inservice Inspection Report Owner Consteeilation Energy, P.O. Box 1475, Baltimore, MD 21203 Owner Certificate of Authorizatlon (If Req.): N/A Plant: Calvert iCliffs Nuclear Power Plant, 1650 Calvert Cliffs Parkway. Lusby, MD 20657 Commer cia!l Sevice Date: 05/08/1975 Plant Unit: 1 National Board Number for Unit 20911 ummary No. CopID Corrp Desc. Categor Item Procedure Method/Sheet/Results System ISO Num Exam Date 2-CV-1005-H-14 COMPONENT SUPPORT F-A F1.10B NDE-6711-CC VT CCO4-4V-186 Accept 041 FSKXMP-492 4/2/00 Ca NDE-571 1-CC VT CCO4tV026 Info 041 FSK-MP-492 5/1/2004 Comments: R-xaminaton lai lad removal revealed no recbe Indications.

607900 11A-ISC COMPONENT SUPPORT F-A F1.40C NDE-5711-CC VT CC04-tV-044 Info 064-B This examination was not completed measreent need to be taken to verify the loedaig on the sprin cans. Exam will be remseduled to verify cods.

607950 11A-2SC COMPONENTSUPPORT F-A F1.40C NDE-5711 -CC VT CC04-V-045 Info 064-B 4r23Q004 Comments: This examination was not completed messmrements need to be taken to verity the eading on the spring cans. Exam wit be rescheduled to verity beds.

eosooo IIA-3SC COMPONENT SUPPORT F-A F1.40C NDE-5711 -CC VT CC04-IV-048 Info 4/23/2004 Comments: This examination was not completed measurements need to be taken to verify the oading on the spring cans. Exam witlbe rescheduled to verify loads.

IIA-4SC COMPONENT SUPPORT F-A F1.40C NDE-5711 CC VT CCO4-V-047 Info 064- 4/23J2004 Comments: This examination was not completed measurement need to be taken to verify the loading on the sprng cans. Exam wit be rescheduled to verify beds.

808075 14496 COMPONENT SUPPORT F-A F1.40C NDE-5711-CC VT CCC4-V-049 Accept 084-B Comments: 4/23/2004 Cf: NO RECORDABLE INDICATIONS NOTED soso8s 1-44-097 COMPONENT SUPPORT F-A F1.40C NDE-5711-CC VT CC04NV-048 Accept 0848 4/3/2004 Comments: NO RECORDABLE INDICATIONS NOTED Class 2 252275 SCHE-11-SI INTEGRAL ATTACHMENT C-C C3.10 NDE-5110-CC MT CC04-lM-001 Accept 052 418/2004 Comments: 72% coverage due to obstructions. Consider for relef request submittal. No rewdable indications 300400 2441-1201-4 ELBOW TO PIPE R-A R1.20 NDE-5412-CC UT 20046U002 Accept 052 91097SH0012 24/2004 NDE-5210-CC PT 2004BP01 I Accept 052 91097SH0012 2/4/2004 Comments: No recordabe Indict noted 300850 24-SI-1201 - R-7 INTEGRAL ATTACHMENT C-C C3.20 NDE-5210-CC PT 2004BP017 Accept 052 91097SH0012 2/2t2oo4 NDE-5210-CC PT CC04-IP-22 Accept 052 91097SH0012 6e30n2004 Comments: INITIAL EXAM IDENTIFIED WELD SPATTER AND AN ARC STRIKE WHICH INTERFERED WITH COMPLETION OF THE EXAM FOLLOWUP EXAM HAD NO RECORDABLE INDICATIONS.

301800 24-SI-1202-H-22 INTEGRAL ATTACHMENT C-C C3.20 NDE-5210-CC PT CC04-IP-001 Accept 052 91097SH0013 3/18N2004 Comments: No recordable Indications noted 307200 14-SI-1201 - 2 ELBOW TO PIPE R-A RI.20 NDE-5412-CC UT CC04-IU-001 Accept 052 91097SH0011, SH0013 3/25no4 Comments: NO RECORDABLE INDICATIONS NOTED 309650 12-SI-1213 -4 PIPE TO ELBOW R-A RI.20 NDE-5412-CC UT CC044U-003 Accept 052 91097SH0001 3/15/2004 Comments: NO RECORDABLE INDICATIONS NOTED 91097SH0026, 91166, 311300 12-SI-1214 - 22 PIPE TO ELBOW R-A RI.20 NDE-5412-CC UT 20048U018 Accept 052 91109 3/101204 Comments: Previousy recorded IndICation bs not recodabe under current Code.

Page of 7 - 10 Attachment I Inservice Inspectlon Report Owner Constellation Energy, P.O. Box 1475. Balimore, MD 21203 Owner Certificate of AuthorizatIon (1fReq.): N/A Plant: Calvert Cliffs Nuclear Power Plant, 1650 Calvert Cliffs Parkway. Lusby, MD 20657 Comrnercial Service Date: 05108/1975 Plant Unit: I National Board Number for UnIt 20911 Summary No. Camp ID Camp Desc. Cater Item Procedure 154kAIftkaaa.,

-Y*IH%-flJfl USWUU

.J4. P.vetFm O.U IMCM MI...m

  • -JJ -*1I Cn-t.Anl P%.,

JOIUd 312250 12-SI-1216-1 TEE TO PIPE R-A R1.20 NDE-5210-CC PT 2004BP015 Accept 052 91097SH000 , 91110 2ten20o4 NDE-5412-CC UT 2004BL1003 Accept 052 91097SH0006, 911 10 2/6rA4 Comments: Consider for relW request due to lited wverage on UT. No recordeble ndications noted.

333550 6-SI-1217-3 ELBOWTOPIPE R-A RI.20 NDE-5412-CC UT 20048U014 Accept 052 91110 3/4/2004 Conmnets: NO RECORDABLE INDICATIONS NOTED.

333900 8-S1-1217-9 PIPETOELBOW R-A R1.20 NDE-5412-CC UT 2004BU019 Accept 052 91110 3t10t2004 Comments: No IndIcatIons Noted 3388 4-5-1209-1 BRANCH CONNECTION TO ELBOW R-A R1.20 NDE-5210-CC PT 2004BP012 Accept 052 91169 2tsnoo4 NDE-5412-CC UT 2004BU1005 Accept 052 91169 2t/U2004 Comnents: Relief Request reguired due to only 50% coverage.

339350 4-SI-1209 -10 ELBOW TO PIPE R-A Ri.20 NDE-5412-CC UT 20048U001 Accept 052 91189 2t/U2004 NDE-5210-CC PT 2004BP013 Accept 052 91189 21562004 Comments: UT exim coverage kilted to 91.5% due to loss of contact on hItradose od etbow.

91172, 910975H0002, 403350 8-CS-1205 -3 PIPE TO ELBOW R-A R1.20 NDE-5412-CC UT 2004BU024 Accept 081 91145 3/16/204 Comments: NO RECORDABLE INDICATIONS NOTED 91172, 91097SH0002.

403400 8-CS-125 -4 ELBOW TO ELBOW R-A R1.20 NDE-412-CC UT 2004BU025 Accept 081 91145 3/16U2004 Comments: NO RECORDABLE INDICATIONS NOTED 91172. 91097SH0002.

403550 8CS-1205-8 PIPE TO ELBOW R-A R1.20 NDE-5412-CC UT 2004811028 Accept 081 91145 3/1U/2004 Comments: NO RECORDABLE INDICATIONS NOTED 91172, 91097SHtO02.

403650 8-CS-1205 -8 PIPE TO ELBOW R-A R1.20 NDE-5412-CC UT 2004BU020 Accept 051 91145 3/11/2004 Comments: No Indications Noted 408550 8-CS-1206 - 20 PIPE TO ELBOW R-A R1.20 NDE-5412-CC UITCC04-IU1-034 Accept 051 910975H0007, 91173 513t2004 NDE-5210-CC PT CC04-IP-019 Accept 051 91097SH0007, 91173 5/Y2004 NDE-54 12-CC UT 2004BU012 Accept 061 91097SH0007,91173 3/4/2004 Comments: ID GEOMETRIC INDICATIONS NOTED 408950 8-CS-1206 - 27 ELBOW TO PIPE R-A R1.20 NDE-5412-CC UT 20048U004 Accept 051 91097SH0007, 91173 217/2004 NDE-5210-CC PT 2004BP014 Accept 081 91097SH0007, 91173 2tet2004 Comments: No recordable hIdications noted.

91097SH0011, 91166.

412950 14-SC-1203 -28 PIPE TO TEE R-A R1.20 NDE-5412-CC UT 2004BU021 Accept 052 91148 3/12/2004 Comments: No Indcations Noted 413000 14-SC-1204 -1 TEE TO PIPE R-A R1.20 NDE-5412-CC UT 20048U022 Accept 052 91097SH0001 3/122004 Comments: No Indications Noted 413100 14-SC-1204 -2 PIPE TO ELBOW R-A R1.20 NDE-5412-CC UT 2004811015 Accept 052 91097SH0001 3NV2004 Comments: IDRoot Geometry noted. No recordable idictions noted.

Page of 8 - 10 Attachment I Inservice Inspection Report Owner Constellation Energy, P.O. Box 1475, Baltimore, MD 21203 Owner Certificate of Authorization (If Req.): N/A Plant: Calvert Cliffs Nuclear Power Plant, 1650 Calvert Cliffs Parkway. Lusby, MD 20657 Commercial Service Date: 05/08/1975 Plant Unit: 1 National Board Number for Unit 20911 Summary No. ComD ID Como Desc. Categor! Item Procedure Method/Sheet/Results System ISO Num Exam Date 413150 14-30-1204 - 3 ELBOW TO ELBOW R-A R1.20 NDE-4412-CC UT 2004BLt1J1Accept 052 91097SHW0t 3/8/2004 Conments: ID Root Geometry noted. No reordable idlctnws noted.

417200 10-SC-1214-1 TEE TO PIPE R-A R1.20 NDE-5412-CC UT 2004BU017 Accept 052 91097SH0001, SHOO05 3/412004 Contents: Wi consider for relief request due to UT coverage.

417950 10-SC-1214 -13 ELBOW TO PIPE R-A R1.20 NDE-5412-CC UT CC04-IU-004 Accept 052 91097SH0001. SHODOS 312412004 Come: NO RECORDABLE INDICATIONS NOTED 419150 -SC-1206S 1A PIPE TO ELBOW R-A R1.20 NDE-5412-CC UT 2004BU013 Accept 052 91097SH001 1 3/4/2(04 Commt : NO RECORDABLE INDICATIONS NOTED.

421400 1/64RV-3993 BRANCH CONNECTION C-F-2 HELB NDE-s IO-CC MT CCO4-4M-008 Accept 083 60345SHO001 4/17/2004 NDE-541 1-CC UT CC04-1U-021 Accept 083 80345SHDD01 4123P2004 Comments: To be considered for relief quest due to coverage.

422350 18-IRV-4001 8-IN. BRANCH CONNECTION AUGMT HELB NDE-5110-CC MT CC04-IM-OOS Accept 083 80345SHW001 4/1712004 NDE-541 1-CC UT CC04-1L-022 Accept 083 80345S3t1tO1 4/23/2C04 Commnts Wll consider for relIef request due to UT coverage.

422400 1-WRV-4002 8-IN. BRANCH CONNECTION AUGMT HELB NOE-110-CC MT CC04-IM-007 Accept 083 f0345SHD001 4/17/2004 NDE-5411-CC UT CC04-lu-020 Accept 083 80345SHo001 4/23/2004 Contnents: WI consider for ree request due to UT coverage.

422450 1/8-RV-4003 8-IN. BRANCH CONNECTION AUGMT HELB NDE-5110-CC MT CC04-IM-004 Acceot 083 80345SHD100 4/17/2004 NDE-541 1-CC UT CCO44U-019 Accept 083 80345SHDC01 4/23/2004 Comment: WM consider for relief request due to UT coverage.

422500 1/-RV4004 t-N. BRANCH CONNECTION AUGMT HELB NDE-51 10-CC MT CC04-IM-003 A-cet 083 I0345SHC001 4117/2C04 NDE-6411 -CC UT CCo44U-024 Accept 083 80345SHW01 4123R004 WN consider for rele request due to UT coverage.

422550 1/8-RV-4005 8-IN. BRANCH CONNECTION AUGMT HELS NDE-51 10-CC MT CC04-IM-02 Accept 083 f0345SHC001 NDE-541 1CC UT CCO44tU-023 Accept 083 60345SHW01 4/2312004 Commiens: Wil consider for relief request due to UT coverage.

433500 18-FW-1218 - R-3 INTEGRAL ATTACHMENT C-C C3.20 NDE-5110.CC MT CC04-IM-010 Accept 045 91093 41282004 NDE-5413-CC UT CCO44U-018 Accept 045 91093 4/2212004 NDE-5403-CC UT CC04-IU-037 Info 045 91093 4/282004 NDE-5110-CC MT CC04-IM-4S Reject 045 91093 4/21/2004 Comment: The rejectable surface ndcation was found to be acceptable using supplemental vdlunet techraiques and the depth was verified to be less than 1/32 by physical removal of the hflicaton.

433550 18-FW-1218 -8 PIPE TO PIPE R-A R1.20 NDE-8411-CC UT CC044U-010 Accept 045 91093 4/1312004 orrnfents: ID ROOT GEOMETRY INDICATIONS NOTED 038 041 045052 436050 PRESSURE RETAINING COMPONENT SYSTEM LEAKAGE TEST C-H C7.10 NOE-5710-CC VT CC044V-171 Accept 083 VARIOUS 567J2004 Conments: No hnications noted.

Page of 9 -10 Attachment 1 Inseivice Inspecton Report Owner Constellation Energy, P.O. Box 1475. Baltimore, MD 21203 Owner Cerifcate of Authorization (1fReq.): N/A Plant Calvert Cliffs Nuclear Power Plant, 1650 Calvert Cliffs Parkway, Lusby. MD 20657 Commercial Service Date: 05/08/1975 Plant Unit: 1 National Board Number for Unit: 20911 e, bln^m VWU...IIItaly-mmo Ulu. t~~il L,*IUO.

I---- fl-.-.

~Ilat tN-t -

WU-.ns If P

0 s uu ti^kAIeka*0.

ivo m.*-.ous

.1t.

JYII Reon

  • Un, I, C.m nnf* LS!aO PRESSURE RETAINING 436150 PRESSURE RETAINING COMPONENT PIPING C-H C7.30 NDE-5710-CC VT CC04-iV-172 Accept COMPONENTS VARIOUS 5Y7/2004 Comments: No Indications vioted.

PRESSURE RETAINING 436250 PRESSURE RETAINING COMPONENT PUMPS C-H C7.50 NDE-5710-CC VT CC044V-179 Accept COMPONENTS VARIOUS Y712004 Comments: No indications noted PRESSURE RETAINING 436350 PRESSURE RETAINING COMPONENT VALVES C-H C7.70 NDE-8710-CC VT CCO4-IV-174 Accept COMPONENTS VARIOUS 5t7/2004 Comments: No Indications noted.

700900 SCHE-1 1-S1 COMPONENT SUPPORT F-A F1 .40B NDE-571 1-CC VT CC04-iV-183 Accept 052 B-3/ 12015-0012 7/2at2004 Comments: No recordable indications noted.

701000 SCHE4-12-51 COMPONENT SUPPORT F-A F1.40B NDE-5711 -CC VT 2004BV004 Accept 052 2/9N2004 Comments: No recordable Indications noted.

701250 24-SI-1001 - R-7 COMPONENT SUPPORT F-A F1 .20B NDE-5711-CC VT 2004BV003 Accept 052 91097SH0012 2/2/2004 Comments: The as found condits were accepted in accordance with ES200400128 Supp No. 000.

701450 24-SI-1202 - H-22 COMPONENT SUPPORT F-A F1.20A NDE-571 1-CC VT 2004BV034 Accept 052 91097SH0013 3/1S/2004 Comments: NO RECORDABLE INDICATIONS NOTED 91097H0026. 911it, 704450 12-SI-1004 - H-2 COMPONENT SUPPORT F-A F1.20B NDE-5711-CC VT CC04-iV-073 Accept 052 91109 3/10/2004 Cormenns: No recorble hdlone noted 704750 10-SI-1002 - R-12 COMPONENT SUPPORT F-A F1.20B NDE-5711-CC VT CC04-iV-001 Accept 052 91097SHo0026 329/2004 Comments: No Recordable indications 708250 6-5I-1010-H-3 COMPONENT SUPPORT F-A F1.20A NDE4711-CC VT 2004BV025 Reject 052 91143, 91100SH0001 3/1/2004 Comments: Issue Report 3R4-09-424 was witten to evaitate the as found conditions. ES200400221 Supp No. 0 accepted fe as found condition and directed the drawins to be dianged.

701550 6-SI-1012 - R-2 COMPONENT SUPPORT F-A F1.20A NDE-5711-CC VT 2004BV024 Accept 052 91144, 9i 100SH0002 3112004 Comments: No recordable Indications noted 711700 4-SI-1208-H-11,R-9 COMPONENT SUPPORT F-A F1.206 NDE-5711-CC VT 20049V028 Accept 052 91097SH0016, SH0017 3V412004 Comments: No recordable ndiations noted.

711750 4-51-1208* H-10, R-8 COMPONENT SUPPORT F-A F1.20B NDE-5711-CC VT CC04-iV-071 Accept 052 91097SH0016, SH0017 3/25/2004 Comments: NO RECORDABLE INDICATIONS NOTED 717850 2-SI-1226 -S-1 COMPONENT SUPPORT F-A F1.20B NDE-4711-CC VT 2004BV016 Accept 052 FSK-MP-432 2t24/2004 Comments: No recordable hidications noted.

717900 2-SI-1228- S-2 COMPONENTSUPPORT F-A F1.20B NDE-571I-CC VT 2004BV017 Reject 052 FSK-MP-432 2124/2004 Comiments: Issue Report IR4409-422 was written to evaluate the as found conditions. ES200400154 Supp No. 0 evaluated the as found conditors and found hemto be acceptable and directed the dawing to be updated to relet the as beit conditions.

717950 2-S1-1226 - S-3 COMPONENTSUPPORT F-A F1.20B NOE-711-CC VT 2004BV018 Accept 052 FSK-MP-432 2124/2004 Comments: Issue Report # IR4-009421 was written to evaluate the as found condtions. ES200400154 SUp, No 0 evauated the as tound conditions endfound thm to be acceptable and directed the dawing to be updated to refec the as butt conditions.

718300 S-CS-1203 - R4 COMPONENT SUPPORT-SNUBBER F-A F1.20C NDE-5711-CC VT 2004BV002 Accept 061 91097SH0005 2N9/2004 Comments: Concrete damage is noiservce Induced. No rewdable indications noted.

Page of 10 -10 Attachment I Inservice Inspection Report Owner Constellation Energy, P.O. Box 1475, Baltimore, MD 21203 Owner Certificate of Authorization (H1Req.): NIA Plant: Calvert Cliffs Nuclear Power Plant, 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Comrnmerclal Service Date: 05108/1975 Plant Unit: 1 National Board Number for Unlt 20911 Summary No. ComD ID Como Desc. Catego Item Procedur Method/Sheet/Results System ISO Num Exam Date 718800 8-CS1205 -H4-5, R4 COMPONENT SUPPORT F-A F1.20A NDE-4711 -CC VT 2004BV033 Accept 061 91172, 91097SHOO02. 91 3/16/2004 Comments: Cleafances found weto acceptable h accordance with ES-02.

721550 14-SC-1203 - A-270 COMPONENT SUPPORT F-A F1.20B NDE-5711-CC VT 2004BV001 Accept 052 91097SHDO11, 91166. 91 2N/2004 Comments: No recordable Idications noted.

721950 14-1204 - H4-5, R-4 COMPONENT SUPPORT F-A F1.20A NDE-5711 -CC VT 2004BV031 Accept 052 91097SH0001 3/6/2004 Comments: SOME MINOR COATINGS DAMAGE ON RESTRAINT NOTED 722300 14-SC-1204 - R-1 COMPONENT SUPPORT F-A F1.20m NDE-5711-CC VT rC04-4V402 Accept 052 910975H0001 3/29/2004 Comrents: No rable Idlostous 722750 12-SC-1200 - H4 COMPONENT SUPPORT F-A F1.20B NDE-5711-CC VT CC04V-072 Accept 052 91097SHOO02, SH1OWS 3/25/2004 Comments: NO RECORDABLE INDICATIONS NOTED 723500 10-SC-1214 - H4-8. R-7 COMPONENT SUPPORT F-A F1.20B NDE-571 1-CC VT CC4-IV-003 Acct 052 91097SH6001, SHOD0s 3/18/2004 Comments: NO RECORDABLE INDICATIONS NOTED 725750 34-MS-1204 COMPONENT SUPPORT-vARIABLE F-A F1.20C NDE-5711-CC VT CCO44V-075 Accept 083 603455sH000 4119/2004 Comments: NO RECORDABLE INDICATIONS NOTED 725800 34-MS-1204 - R-e COMPONENT SUPPORT F-A F1.20B NDE-4711-CC VT CC04-rIv-76 Accept 063 60345SH0001 4R0/2034 Comments: NO RECORDABLE INDICATIONS NOTED 725950 34-MS-1205 1 COMPONENT SUPPORT-VARIABLE F-A F1.20C NDE-5711-CC VT CCo4-IV-077 Accept 083 80345SH0001 4/19/2004 commets: NO RECORDABLE INDICATIONS NOTED 726e00 6-MS-1208 - R-2 COMPONENT SUPPORT F-A F1.20B NDE-57i1-CC VT CCU 4-IV-415 Accept 063 eO345SHOO01. SH0002 419/2004 Comments: No nc ble Indlcations.

727200 16-FW-1218 - R4 COMPONENT SUFPORT-SNUBBER F1.20C NDE-5711-CC VT CCO4IV-037 Accept 045 91M 4/21rdOO4 Comments: No recordable indications.

ENCLOSURE (2)

CALVERT CLIFFS NUCLEAR POWER PLANT, INSERVICE INSPECTION

SUMMARY

REPORT FOR CALVERT CLIFFS UNIT 1 ASME BOILER & PRESSURE VESSEL CODE SECTION XI, FORM NIS-2 Calvert Cliffs Nuclear Power Plant, Inc.

August 4, 2004

2004-1 Class I and 2 NIS-2's Completed

%N&"4Imb fu'ti:Vi, 'I 1199700129 97-1-027 1MOV658 Two 1200200636 2003-1 -047a 1CKVCVC-1 87 One 2003-1-047b 1#CC5-1005 One 1200200640 2003-1 -M48a 1CKVCVC-184 Two 2003-1 -048b 1#CC7-1009 Two 1200200641 2003-1-049a 1CKVCVC-435 One 2003-1-049b 1#CC5-1006 One 1200202505 2002-1-049b 1HVCVC-172 Two 2002-1 -049c 1#CC7-1 002 TWO 1200202602 2002-1-033 1PUMPRC11B(s) One 1200202689 2002-1 -050a 1CKVCVC-1 71 Two 2002-1 -050b 1#CC7-1002 Two 1200202762 2002-1-051 1CV1OF One 1200203109 2003-1-046a 1CKVSI-426 Two 2003-1 -046b 1#DC2-1003 Two 1200203364 2003-1-056 1RV200 One 2003-1-056a 1#CC10-1007 One 1200203390 2004-1-027 1PZVRXI1 One 1200203521 2004-1-010 1CV4070 Two 1200203958 2003-1-032- IPIJMPRC12A(s)- One 1200203966 2003-1-008 1RV201 One 2003-1 -008a 1#CC10-1008 One 1200204093 2003-1-057 1ERV404 One 2003-1 -057a 1#CCI0-1004 One 1200204377 2003-1-058 1ERV402 One 2003-1 -058a 1#CCI0-1003 One 1200204580 2002-1-052 1RV200 One 2002-1-062 1#CCI0-1007 One 1200204888 2002-1-060 1#CC-2,1" & under One 2003-1-022b 1#CC7-1001 Two 1200205233 2003-1-022c 1HVCVC-166 Two 2003-1 -022a 1CKVCVC-165 Two 2003-1-052c 1HVCVC-178 Two 1200205235 2003-1 -052a 1CKVCVC-177 Two 2003-1 -052b 1#CC7-1003 Two 1200205240 2003-1-077 1#CCI0-1003-H3 One 1200205247 2003-1-078 1#CC10-1004-H3 One 2003-1-023b 1#CCIO-1001 One 1200205332 2003-1-023a 1MOV403 One 2003-1-024a 1MOV405 One 1200205334 2003-1 -024c 1#CC10-1002-R12 One 2003-1-024b 1#CC10-1002 One MEIU Reference No. 200447-22-3496

2004-1 Class 1 and 2 NIS-2's Completed 1200301717 2003-1-018 1PUMPRC11 B(s) One 1200303202 2003-1-080 1ACC233X-SUP Two 1200303410 2003-1-072 1CV648 One 1200303794 2003-1-075 1ACC233Z-SUP Two 1200304508 2003-1-081 1HVSI-4163 Two 1200400341 2004-1-009a 1#HC7-1004 Two 2004-1-009b 1#HC7-1004-H2/R3 Two 1200401939 2004-1-017 1#GC9-1003-R6 Two SNUB POOL SNUB-0-004 *Snubber Pool 1, 2, & 3 MEWU Reference No. 2004-47-22-3496

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xl

1. Owner: Calvert Cliffs Nuclear Power Plant, Inc. Date: 514/2004 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet I of 2 (address)
2. Plant: Calvert Cliffs Nuclear Power Plant Unit: One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 97-1-027, MWO No. 1199700129 (address) (P.O. no., job no., etc.)

Type Code Symbol Stamp: N/A

3. Work Performed by: Calvert Cliffs Nuclear Power Plant Dept.

(name) Authorization No.: N/A Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, Md. 20657 Section X) Class: Two (address)

4. Identification of Systern SystemNumber 052 SystemName: Safety Injection 5.(a)Applicable ConstructionCode and Class: ASME Draft Code for Pumps & Valves,1968 Edition, March 1970 Add; Class 2 (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition
6. Identification of Components Repaired or Replaced and Replacement Components: ASME Repaired, Code Name of Name of Manufacturers National Other Year Replaced, oi Stamped Conponet Manufacturer Serial Number Board No. Identification Built Replacemen (Yes or No)

Valve Velan Enginnering 1-MOV-658 NIA Low Pressure Safety Injection 197S Repalred/Repi No Co. system supply to Shut Down aced Cooling Heat Exchangers Isolation valve

7. Description of Work:

This plan was for the pluging of the leak off line and seal welding the plug on 1MOV-658, Low Pressure Safety Injection system supply to Shut Down Cooling Heat Exchangers isolation valve.

8. Tests Conducted: Hydrostatic:E PneumaticE Nominal Operating Pressure: Inservice: 0 Leakage: C] Functional: El Pressure: NIA psi. Test Temperature: NIA Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

No Section Xi Pre-Service NDE was performed in support of this activity.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Renair/Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A

/ GCharles H. Ballard Signed: Engineering Technician Date: 5/4/2004 d-wnf-d)e~e ignee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the periodto /-2 - O .andstate to the bestofmy knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section X1.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures descrbed in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

___dCommnissions: IV8 '?eTA/ 4'r M o . //7 ___7

-Inspector's Signature National Board, State, and Endorsements Date:e.-,/ 200 4

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY

. As Required Required by the Provisions of the ASME Code Section Xl

1. Owner: Calvert Cliffs Nuclear Power Plant, Inc. Date: 6/1512004 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet 1 of 2 (address)
2. Plant: Calvert Cliffs Nuclear Power Plant Unit: One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-047a, MWO No. 1200200636 (address) (P.O. no., job no., etc.)

Type Code Symbol Stamp: N/A

3. Work Performed by Calvert Cliffs Nuclear Power Plant Dept. Authorization No.: N/A (name)

Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class: One (address)

4. Identification of System: System Number 041 System Name: Chemical Volume Control 5.(a) Applicable Construction Code and Class: ASME Draft Code for Pumps & Valves, 1968 Edition, March 1970 Add; Class I (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition
6. Identification of Components Repaired or Replaced and Replacement Components: ASME Repaired, Code Name of Name of Manufacturers National Other Year Replaced, oi Stamped Comuponet Manufacturer Serial Number Board No. Identification Built Replacemen (Yes or No)

Valve Velan Engineering SN: 335 N/A #11 Regen. Heat Exch. to #IIA 1975 Repaired/Repl Yes Co. RCS Cold Leg Loop Check Valve aced CheckValve Enertech Inc. 408934 SN: 11269 NIA Valve, Nozzle Check, 2 In., 1500 2002 Replacement Yes lb., Large Groove connections, Enertech, Tp. KRV (Mark#

212M3N)

7. Description of Work:

This plan was for the work needed to replace 1-CKVCVC-1 87, #11 Regen. Heat Exch. to #11A RCS Cold Leg Loop Check Valve.

8. Tests Conducted: Hydrostatic:[] Pneumatic1l Nominal Operating Pressure: Inservice: O Leakage: 3 Functional: E Pressure: 2355 psi. Test Temperature: 74 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (l) size is 8-1/2 in. x I I in., (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section Xi System Leakage Test of the affected component was performed during the system conditions listed in section 8. of this report.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this RevalrlReplacgement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: NIA Expiration Date: N/A 7 A7</ / Charles H. Ballard Signed: rcs Engineering Technician Date: 6/15/2004 Owner or eesanee, Title '

Certificate of Inservice Inspection 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period 9a9-a -3 to i - O -° , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

bDo0h-2-D A . $/)#7O//Z F AUZ, 'OI; t&r§ZS Pot 7EZ- -IW Commissions: AJiJi9 3,1 ,trOn7/.1 4-J7/

5  ;; 1 16 1217791o A40115

,.Insectoes Signature National Board, State, and Endorsements Date: /&'

/ 200 h,

FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES As Required by the ProvisIons of the ASME Code,Section II, D islon 1 Pg. I of_ 2

1. Manufactured and certified by Eiertech, A Diy. of Curtiss-Wright Flow Control Corp., 2950 BIrch St., Brea, CA 92821 Iname and address of N Certiflcate Holder)
2. Manufactured for *CalvertCliffs Nuclear Power Plant, PO Box 17323. Baltimore, MD 21297-1323 Iname and address ef Purchaser)
3. Location of Instaliation Calvert Cliffs nuclear Power PIant- 1650 Calvert Cliffs Parkway, Lusby, MD 20657 (name and address)
4. ModelNo., Series No., or Type KRV KR Drawing raig MD20990 Rev. A CRN A____None_____ None
6. ASME Code. Section ilt. Division 1: 1995 W9. 1 NQne (edition) laddenda date) (claess (Code Cese no.)
6. Pump or vaive Nozzle Check Valve Nominal Inlet size 2 Outlet size 2 On.7 ItnNl
7. Material: Body SA-479 Type 316 86oinel N/A DsA .-479 Tye 16 Bolting N/A (a) .. W IC) (d) (e1 Cert. Nat'l Body Bonnet Disk Holder's Board Serial Serial Serial Serial No. No. No. No. No.

11256 None KNG-001

  • None KNH-001 11257 None KNG-002 None KNH-002 11258 None KNG-003 None KNH-003 11259- None KNG-004 None KNH-004 11260 None KNG-005 None KNH-005 11261 None KNG-006 None KNH-006 11262 None KNG-007 None KNH-007 11263 None
  • KNG-OO0 None KNH-008 11264 None KNG-009 None KNH-009 11265 None KNG-01 0 None KNH-010 11266 None KNG-011 None KNH-O11 11267 None KNG-012 None KNH-012 11268 None KNG-013 None KNH-013 11269 None KNG-014 None KNH-014 11270 None KNG-015 None KNH-015 11271 None *KNG-016 None KNH-016 11t272 None KNG-017 None KNH-017 11273 None KNG-018 None KNH-01 B I . .
  • Supplemental kormation in form of Usts. sketches. br drawings may be used provided (11 adze IsBI x 11, (2)hIformation hI kems I through 4 on this Date Report is Included on each sheet. 131each Sheet is numbered and the number of sheets Is recorded at the top of this foT.

(12188) This form (Eoo0371 may be obtalned from the Order Dept.. ASME. 22 Law Drive. Box 2300, Fairfield. NJ 07007.2300. REPRINT M3

.M NPV-1 (Back-Pg. 2 of 2 )

c H11256 thru Certificate HOlder'S Serial No. 11273 _

8. Design conditions 2800 psi 250 _ or valve pressuro class 1500 (11 (pressurel Itemperaturel
9. Cold working pressure 3600 psiastIO1,F
10. Hydrostatic test 5400 psi. Disk differential test pressure N/A _psi II. Remarks: Qly 18, Enertech Job Number 29345V CERTIFICATION OF DESIGN Design Specification certified by JohnR.Sponsel, P.E. State MD Re9. no 17308 Design Report certified by IraJ,Silverman P.E. Stase Reg. no. 23241 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this pump or valve conforms to the rules for construction of the ASME Code,Section III, Division 1.

N Certificate of Authorization No. N-2826 ExpM - 10/11/05 Date - Ech.Aoiv Enelecsme of Cit-WrigAhePbw CoolCofp Signed e (N Certificate Holder (authorized represantaftve)

CERTIFICATE OF INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boler and Pressure Vessel Inspectors and the State or Province of Califomia snd employsd by HSB CT of Connecticut have inspected the pump, or valve, described In this Data Report on l . t9Z . and state that to the best of my knowledge and belief, the Certificate Holder has con-structed this pump, or valve, In accordance with the ASME Code.Section III, Division 1.

By signing this certificate; neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the component described in this Data Report; Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.

Date /. £390Signed eiz P ESo missions e (Auhorized Inspectori (Nat'l 3d. (nict. endotsements) and stae or prov. and no.1 (11For manually operated valves only.

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xl

1. Owner: Calvert Cliffs Nuclear Power Plant, Inc. Date: 611412004 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet 1 of 2 (address)
2. Plant: Calvert Cliffs Nuclear Power Plant Unit: One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-047b, MWO No. 1200200636 (address) (P.O. no., job no., etc.)

Type Code Symbol Stamp: N/A

3. WorkPerformedby: Calvert Cliffs Nuclear Power Plant Dept. Authorization No.: N/A (name)

Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class: One (address)

4. Identification of System: System Number 041 System Name: Chemical Volume Control 5.(a) Applicable Construction Code and Class: ASME B31.7 1969 Edition, Sum. 1971 Add; Class 1 (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition
6. Identification of Components Repaired or Replaced and Replacement Components: ASME Repaired, Code Name of Name of Manufacturers National Other Year Replaced, ox Stamped Componet Manufacturer Serial Number Board No. Identification Built Replacemen (Yes or No)

Piping System Bechtel 2"CC-5-1005 N/A #11A Charging Line Stop Valve 1975 Repaired/Repi No aced Pipe DuBose National 400298 Ht.#: 8324H N/A Pipe, 2 In., Sch. 160, ASME SA- 2000 Replacement No Energy Services 376, Tp. 316 Inc.

Nut Mackson Inc. 408227 Ht.#: S44018 NIA Nut, Heavy Hex, 7/8 In.X 9 TPI, 2002 Replacement No ASME SA-194 Gr. 2H AlIthread Rod Mackson Inc. 410155 Ht.#: S20751 -N/A Rod, Aluth read, 7/8 In. X 9 TPI, 2003 Replacement No ASME SA-193 Gr. B7 Flange Energy & Process 411064 Heat Code: N/A Flange, 2 In., 1500 lb., Large 2003 Replacement No Corporation XX13 Tongue, Weld Neck, ASME SA-182, Tp. F 316

7. Description of Work:

This plan was for the piping, fittings, hanger support work and fasteners needed to support the replacement of 1-CKVCVC-187, #11 Regen. Heat Exch. to #11A RCS Cold Leg Loop Check Valve.

8. Tests Conducted: Hydrostatic:. PneumaticC Nominal Operating Pressure: Inservice: E Leakage: W Functional: E Pressure: 2355 psi. Test Temperature: 74 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 1I in., (2) information in Items 1through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet2of 2 FORM NIS-2 (Back)

9. Remarks:

A Section Xl VT-1 Visual Examination of the replacement threaded fasteners was performed to satisfy Section Xi Pre-Service NDE Requirements. A Section Xl System Leakage Test of the affected component was performed durina the system conditions listed in section 8. of this report. A Section Xi Surface Examination of the affected component was performed to satisy Section Xi Pre-Service Requirements.

Code Case N-416-2 was invoked to satisfy Section Xl required pressure tests. Addtional Section III Examinations were performed (as applicable) to satisfy Code Case N-416-2 and Req.Guide 1.147.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Repair/Reopacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H.Ballard Signed: G Engineering Technician Date: 6/14/2004 Ownerror 6wrefiDesi-g e, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period 9-A2 -03 to S - XO ° , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

OOci-JDz-I 4 - S 4in'/[l4 r-cv -

cT,;- ,,d 5 PetYL - -r-6 Commissions: NA/ 'j&3 J. M//7/< 8,'/

, nsnecto,'s Signature National Board, State, and Endorsements Date: /6 200 -

- . I

. - J FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xi

1. Owner. Calvert Cliffs Nuclear Power Plant, Inc. Date: 6/1412004 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet I of 2 (address)
2. Plant: Calvert Cliffs Nuclear Power Plant Unit: One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-048a, MWO No. 1200200640 (address) (P.O. no., job no., etc.)

Type Code Symbol Stamp: N/A

3. WorkPerfornedby: Calvert Cliffs Nuclear Power Plant Dept. Authorization No.: N/A (name)

Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class: Two (address)

4. Identification of System: System Number 041 System Name: , Chemical Volume Control 5.(a) Applicable Construction Code and Class: ASME Draft Code for Pumps & Valves,1968 Edition, March 1970 Add; Class 1:

(b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition

6. Identification of Components Repaired or Replaced and Replacement Components: ASME Repaired, Code Name of Name of Manufacturers National Other Year Replaced, ot Stamped Componet Manufacturer Serial Number Board No. Identification Built Replacemen (Yes or No)

Valve Velan Engineering SN: 1404 NIA #1I Regen. Heat Exchanger Inlet 1975 Repaired/Repi Yes Co. Check Valve (Containment need Isolation)

Check Valve Enertech Inc. 408934 SN: 11266 N/A Valve, Nozzle Check, 2 In., 1500 2002 Replacement Yes lb., Large Groove connections, Enertech, Tp. KRV (Mark#

212M3N)

7. Description of Work:

This plan was for the work and parts needed to replace 1-CKVCVC-184, #11 Regen. Heat Exchanger Inlet Check Valve.

8. Tests Conducted: Hydrostatic:j] PneumaticC Nominal Operating Pressure: Inservice: r Leakage: 6 Functional: a kPressure: 2355 psi. Test T icnperatwe. Z74 Dcg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) information in Items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

-I 1 j I_0 Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section XI System Leakace Test of the affected component was performed during the system conditions listed in section 8. of this report.

Applicable Manufacturer's Data Reports to be Attached

-Certificate of Compliance We certify that the statements made in this. tOwnt tre correct and that this Repalr/Replacement conforms to the rules of the ASM IWde, Section X1.

Type Code Symbol Stamnp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H.Ballard Signed: Engineering Technician Date: 6/14/2004 Ownmer ori5AersTsizhee, it Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period 9 - a S -5O3 to 6 - rO 9Y , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

DOAb)4,O A . Se-/ 1 ,6J4 F:ce ,A,..

,U1)L2_ai< PL-& Commissions: /dC 9 831 , //7/ 4-"11 A Insnctors Signature National Board, State, and Endorsements Date: t 1 200--

FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES*

As Required by the Provisions of the ASME Code,Section III, DIv1slon I Pg. 1of.2...

1. Manufactured and certified by Enertech, A Diy. of Curliss-Wright Flow Control Corp., 2950 Birch St.. Brea, CA 92821 (name d addresa of N Certificate Holderl
2. Manufacted for *Calvert Cliffs Nuclear Power Plant, PO Box 17323, Baltimore, MD 21297-1323 (name and address ef Purchaser)
3. Locationof installetion Calvert Cliffs nuclear Power Plant, 1650 Calvert Cliffs Parkway, Lusby, MD 20657 (name and address)
4. Model No., Series No., or Type KRV Drawing MD20990 Rev. A CRl None
6. ASME Codo. Section RI, Division 1: 1995 1q96 I NQne leditionl leddends date) (isasl - (Code Case .o.I
6. Pump or valve Nozzle Check Valve Nominal Inlet size Outlet size 2 (in.) oin.g
7. Material: Body Bonnet ______________ DiskSA.-479 Type 318 Botn N/A la) .. lb) , c) (d) (al Cert. Nat'l Body Bonnet Disk Holder's Board Serial Serial Serial Serial No. No. No. No. No.

11256 None KNG-001 None KNH-001 11257 None KNG-002 None KNH-002 11258 None KNG-003 None KNH-003 11259 None KNG-004 None KNH-004 11260 None KNG-005 None KNH-005 11261 None KNG-006

  • None KNH-006 11262 None KNG-007 None KNH-007 11263 None KNG-008 None KNH-008 11264 None KNG-009 None KNH-009 11265 None KNG-010 None KNH-010 11266 None KNG-011 None KNH-01 1 11267 None KNG-012 None KNH-01 2 11268 None KNG-013 None KNH-013 11269 None KNG-014 None KNH-014 11270 None KNG-O1 5 None KNHII-015 11271 None *KNG-016 None KNH-016 11272 None KNG-017 None KNH-017 11273 None KNG-018 None KNH4018
  • Supptementai Information in form of Ustsasketches, br drawings may be used provided (II size Is 8 1 x 11, 12! Information In Items 1 through 4 on this Data Report is Included on each shoet, 13) each sheet Is numbered and the number of sheets Isrecorded at the top of this form.

112/88) ThIs form IE000371 may be obtained from the Order Dept.. ASME. 22 Law Drive. Box 2300. Fairfield, NJ 07007 2300. REPRINT W93

  • I -t-AMNPV-1 IBack-Pg.2o:f 2 ) ' 1 11256 thru Certificate Holder's Serial No. 11273
8. Design conditions 2800 psi 250 _ or valve presaur dess 1500 (pressure) ltemperature)
9. Cold working pressure 3600 psi at 1 o0F
10. Hydrostatic test 540 psi. Disk differential test pressure N/A psi I1. Remarks: Oty. 18, Enertech Job Number 29345V CERTIFICATION OF DESIGN Design Specification certified by John R. Sponsel, I P.i State MD Fleg. no. 17308 Design Report certified by- Ira J, Silverman PE State Ceg no. 23241 CERTIFICATE OF COMPLIANCE We certify that the statements made In this report are correct and that this pump or valve conforms to the rules for construction of the ASME Code, Section Ill, Division 1.

N Certificate of Authoritation No. N-2826 10/11/05 Data Nmame me//6/A'3 Frb ADhio !CwFtCo Signed  ? d Z INCertificate Holder) (authorized representativei CERTIFICATE OF INSPECTION 1, the undersigned. holding a valid commission Issued by the National Board of Bolrer and Pressure Vessel Inspectors and the State or Province of Caitomia and employ d by HSB CT of Connedicut have inspected the pump, or valve. described in this Data Report on l 5. O and state that to the best of my knowledge and bellel, the Certificate Holder has corn structed this pump. or valve, In acaordance with the ASME Code,Section III, Division 1.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or Implied, concerning the component described In this Data Report: Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.

Data Signed AE.. issions ComComm '>'a ' ,0C4,% 2 '

(Authorized Inspector) (Net'l. Wd. ncd.endorsements) and stats or prev. and no.)

(1)For manually oparatrd valves only.

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xl

1. Owner: Calvert Cliffs Nuclear Power Plant, Inc. Date: 611412004 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet I of 2 (address)
2. Plant: Calvert Cliffs Nuclear Power Plant Unit: One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-048b, MWO No. 1200200640 (address) (P.O. no., job no., etc.)

Type Code Symbol Stamp: N/A

3. Work Performed by: Calvert Cliffs Nuclear Power Plant Dept. Authorization No.: N/A (name)

Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class: Two (address)

4. Identification of System System Number 041 SystemName: ChemIcal Volume Control 5.(a)ApplicableConstructionCodeandClass: ASME B31.7 1969 Edition, Sum. 1971 Add; Class 2 (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition
6. Identification of Components Repaired or Replaced and Replacement Components: ASME Repaired, Code Name of Name of Manufacturers National Other Year Replaced, oi Stamped Componet Manufacturer Serial Number Board No. Identification Built Replacemen (Yes or No)

Piping System Bechtel 2" CC-7-1009 N/A Charging Pumps discharge piping 1975 Repaired/Repi No to Containment Penatration #28. aced Pipe DuBose National 400298 Ht.#: 8324H N/A Pipe, 2 In, Sch. 160, ASME SA- 2000 Replacement No Energy Services 376, Tp. 316 Inc.

Nut Mackson Inc. 408227 Ht.#: S44018 NIA Nut, Heavy Hex, 7/8 In.X 9 TPI, 2002 Replacement No ASME SA-1 94 Gr. 2H Ailthread Rod Mackson Inc. 410155 Ht.#: S20751 N/A Rod, Allthread, 7/8 In. X 9 TPI, 2003 Replacement No ASME SA-193 Gr. B7 Flange DuBose National 409374 Ht. Code: N/A Flange, 2 In., 1500 lb., Large 2003 Replacement No Energy Services BHZ Tongue, Socketweld, ASME SA-Inc. 182, Gr. F316

7. Description of Work:

This plan was for the piping, fittings, hanger support work and fasteners needed to support the replacement of 1-CKVCVC-1 84, #11 Regen. Heat Exchanger Inlet Check Valve.

8. Tests Conducted: Hydrostatic:[] Pneumaticf] Nominal Operating Pressure: Inservice: El Leakage: i Functional: al Pressure: 2355 psi. Test Temperature: 74 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) information in Items 1through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section XI Svstem Leakaae Test of the affected component was oerformed durina the system conditions listed in section 8. of this report. Code Case N-416-2 was invoked to satisfy Section XI required pressure tests. Addtional Section III Examinations were performed (as applicable) to sahsfv Code Case N-416-2 and Rea.Guide 1.147.

Applicable Manufacturer's Data Reports to be Attached We certify that the statements made m s repon are correcxaa this Repair/Reolacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp: NIA Certificate of Authorization No.: N/A Expiration Date: N/A Charles H. Ballard Signed: Engineering Technician Date: 6/14/2004 Owner or Owner's Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described inthisOwner'sReportduringtheperiod 9-S-03 to 8-t°v , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

Da'J41D /1, SPI-PI/Df AL q1Z reiAJ/ AFEZ Is" Commissions: A £ 9

  • 3 I . ,4-/) 1/7/ A.ta /

Da t Ae 00 ' A'6Natioaiioard State, and Endorsements Date: G -& 200 C~-

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl

1. Owner: Calvert Cliffs Nuclear Power Plant, Inc. Date: 611612004 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet I of 2 (address) z ., Plant+.

... Calvert Cllffs Nuclear Power Plant Unit: One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-049a, MWO No. 1200200641 (address) (P.O. no., job no., etc.)

apt. Type Code Symbol Stamp: N/A

3. Work Performed by: Calvert Cliffs Nuclear Power Plant D4 ap.Authorization No.: N/A (name)

Exp Date: N/A 1650 Calvert Cllffs Parkway, Lusby, MD 20657 Section XI Class: One (address)

4. Identification of Systemn System Number 041 System Name: Chemical Volume Control 5.(a) Applicable Construction Code and Class: ASME Draft Code for Pumps & Valves, 1968 Edition, March 1970 Add; Class I I (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition
6. Identification of Components Repaired or Replaced and Replacement Components: ASME Repaired, Code Name of Name of Manufacturers National Other Year Replaced, oi Stamped Cormponet Manufacturer Serial Number Board No. Identification Built Replacemen (Yes or No)

Valve Velan Engineering SN: 4248 NIA #11 Regen. Heat Exch. to U11A 1975 Repalred/Rept Yes Co. RCS Cold Leg Loop CV By Pass aced Check Valve Check Valve Enertech Inc. 408934 SN: 11270 N/A Valve, Nozzle Check, 2 In., 1500 2002 Replacement Yes lb., Large Groove connections, Enertech, Tp. KRV (Mark #

212M3N) -

7. Description of Work:

This plan was for the work needed to replace 1-CKVCVC-435, #11 Regen. Heat Exch. to #1 1A RCS Cold Leg Loop CV By Pass Check Valve.

8. Tests Conducted: Hydrostatic:5 PncumaticO Nominal Operating Pressure: Inservice: E Leakage:R Functional:fl Pressure: 2355 psi. Test Temperature: 74 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x I I in., (2) information in Items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet2of 2 It7. FORM NIS-2 (Back)

9. Remarks:

A Section Xl System Leakage Test of the affected component was performed during the system conditions listed in section 8. of this report.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Revalr[Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A

~elr 7Charles H. Ballard Signed: Eni ng Technician Date: 6/16/2004 Owner or Owner's Designee, Title Certificate of Inservice Inspection 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described inthisOwner'sReportduringtheperiod /-1/103 to (~// 0y and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

b644 1 A -S43HfmH /f,,.

G 'J-t Commissions: AJ 83 913/, Yad //)1 , 4O'WE r JS r /Nt7i7o Br SA// a ESS

.. Insnector's Sian~ature National Board, State, and Endorsements Date: i -/ 7 -------2-0-0D--

FORM NPV-1 CERTIFICATk HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES As Required by the Provisions of the ASME Code, Section 111, Division I 2 Pg. 1 oi.2..

1. Manufactured and certified by Enertech, A Div. of Curtiss-Wright Flow Control Corp., 2950 Birch St., Brea, CA 92821 Inamerand eddrest of N Certficate Holder)
2. Manufactured for Calvert Cliffs Nuclear Power Plant, PO Box 17323, Baltimore, MD 21297-1323 Inarme and address of Prchaser)
3. Locatlon of installation Calvert Cliffs nuclear Power Plant; 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Iname and address)
4. Model No., Series No., or Type KRV Drawing MD20990 Rev. A CRN None
6. ASME Cod, Sectlon* Ilt, Division 1: 1995 I9 . NoneWm ledition) (addenda date) (class) (Code Case no.)
6. Pump or vave Nozzle Check Valve Nominal Inlet slzo 2 Outlet size 2 on.) (In. N
7. Material: Body SA-479 Type 316 Bdninet N/A Disk SX-479 TYPe 316 BolN/A (a) .. b) (c) (dl (a)
  • Cart. Nat'I Body Bonnet DlsIk Holderes Board Serial Serial Serial Serial No. No. No. No. No.

11256 None KNG-001

  • Non KNH-001 11257 None KNG-002 None KNH-002 11258 None KNG-003 None KNH-003 11259 None KNG-004 None KNH-004 11260 .None KNG-005 None KNH-005 11261 None KNG406 . None KNH 006 11262 None KNG-007 None KNH-007 11263 None KNG-008 None KNH-008 11264 None KNG-009 None KNH-009 11265 None KNG-O1 0 None KNH-010
  • 11266 None KNG-01 1 None KNH-011 11267 None KNG-012 None KNH-012 11268 None *KNG-013 None KNH-013 11269 None KNG-014 None KNH-014 11270 None KNG-015 None KNH-015 11271 None *KNG-016 None KNH-01 6
  • 11272 None KNG-017 None KNH-017 11273 None KNG-018 None KNH-018
  • Supplamentdl Information in form of lists, sketches. br drawings may be used provided (1) size Is 81$ x 11, (2) information In iems 1 through 4 on this Data Report Is Included on each sheet. (3)each sheet is numbered end the number of sheets Is recorded at the top of this forn.

(12)88) This form iE000371 may be obtained from the Order Dept.. ASME, 22 Law Drive, 3ox 2300, Fairfield, NJ 07007-2300. htPINTOW4

r. - -

IM NPV-1 (Back -Pg. 2 of 2 .)

o 'S 11256th7

... ICertificate Hoideres Serial No. 11273 S. Design conditions 2800 _ 250 _ F or valve pressure dass 1600 11)

(pressure) Itemperature)

9. Cold working pressure 3600 psi at 1I 60F
10. Hydrostatic test 5400 psi. Disk differential test pressure N/A IPsI I1. Remarks: Oty. 18, Enertech Job Number 29345V CERTIFICATION OF DESIGN DesignSpecificationcertifiedby John R. Sponsel, 11 P.E. Ste MD Rg. no. 17308 Design Report certified... by Ir J. Silverman Saeng CA o 23241 CERTIFICATE OF COMPUANCE We certify that the statements made In this report are correct and that this pump or valve conforms to the rules for construction of the ASME Code,Section III, Division 1.

N Certificate of Authoiation No N-2826 110/11/05 Dato Name E Deiv.

Ane C)'k

  • FowC Cop Signed.

(NCenimicate Holderl (authorized representaftv)

CERTIFICATE OF INSPECTION 1I the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the Stat. or Province of California and emp ed byBCT of Connecticut have Inspected the pump, or valve, described in this Data Report on

  • 1
  • OT5 , and state that to the best of my knowledge and belief, the Certificate Hold'er has con-structed this pump, or valve, In accordance with the ASME Cods,Section III, DivIsIon 1.

By signing this certiflcate; neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the component described in this Data Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.

Date -bL0L350SIgned A(Authorized 7Inspector ommissions eA4 pJ864wA (Nael. 8d. lincL endorsements) and stat or prov. and nol

1) For manually operated valves only.

FORM NIS-2 OWNER'S REPORT FOR REPAIR I REPLACEMENT ACTIVITY As Required by the Provislons of the ASME Code Section Xi

1. Owner: Calvert Cliffs Nuclear Power Plant, Inc. Date: 611612004 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet I of g (addess)
2. Plant: Calvert Cliffs Nuclear Power Plant unit. One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&F RNo. 2003-1-049b, MWO No. 1200200641 (address) (P.O. no.,job no., e*c.)

Type Code Symbol Stamp: NA

3. WorkPerformedby: Calvert Cliffs Nuclear Power Plant Dept. Authorization No.: N/A (name)

Exp Date: N 1650 Calvert Cliffs Parkway, Lusby, MD 20657 SectionXI Class: One (addess)

4. Identification of System: SystemNumber 041 SystemName: Chemical Volume Control 5.(a) Applicable Construction Code and Class: A.SME B31.7 1969 Edition, Sum. 1971 Add; Class I (b) Applicable Sect XI Ed. for RepairslReplacement 1998 Edition Identificatidon of Components Repaired or Replaced ind Replacement Components: .. . ASME.

Rcpaired, Code Name of Name of Manufacturers National Other Year Replaced, o: Stamped Componet Manufacturer Serial Number BoardNo. Identification Built Replacemer (Yes or No)

Piping System Bechtel 2"CC-5-1006 N/A #11 Regen. Heat Exch. to II1A 1975 Repalred/Rept No RCS Cold Leg Loop CV By Pass aced piping Pipe DuBose National 400298 E1.0s 324E N/A Pipe, 2 In., Sch. 160, ASME.SA- 2000 Replacement

  • No Energy Services 376, Tp. 316 Inc.

Nut Mackson Inc. 408227 Ht: 54401S N/A Nut, Heavy Rex, 7/8 In. X 9 TPI, 2002 Replacement No ASMESA-194 Gr.2H Allthread Rod Macksou Inc. 410155 EtA. S20751 N/A Rod, Ailthread, 7/8 In. X 9 TPI, 2003 Replacement No ASME SA-193 Gr. B7

'Flange Energy & Process 411064 Beat Code: N/A Flang, 2 In, 1500 lb., Large 2003 Replacement no

- Corporation XX13 Tongue, Weld Neck, ASME SA-182, Tp. F 316 Reducing Tee Energy & Process 411064 Ht: 70802 NIA Tee, Reducing, 2 In. X 314 In., 2003 Replacement No Corporation Sc.I60, butt weld, ASME SA-403, Gr. WP316 Plate Energy Steel & 402572 Ht.: N/A Plate, Steel 1/4 In. X 48 In. X 96 2001 Replacement No Supply Co. 832N34270 In., ASME SA-36 Pipe Tloga Pipe Supply 402564 Et.#: L42618 NIA Pipe, 3/4 In. Sch. 160, ASME SA- 2001 Replacement No Co. Inc. 376, Tp. 316

7. Description of Work:

This plan was for the piping, fittings, hanger support work and fasteners needed to support the replacement of 1-CKVCVC-435, #I11 Regen. Heat Exch. to #11A RCS Cold Leg Loop CV By Pass Check Valve.

NOTE: Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size is 8-1/2 in x l lin., (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheetgpf .-

fib FORM NIS-2 (Back)

8. Tests Conducted: HYdostatic:O PneumaticO Nominal Operating Pressure: is ervice: 0 Leakage: E Functional: a Pressure: 2355 psi. Test Temperature: 74 Deg. F
9. Remarks:

A Section Xi VT-1 Visual Examination of the replacement threaded fasteners was oerformed to satisfv Section Xi Pre-Service NDE Requirements. A Section XI System Leakaqe Test of the affected component was Performed durina the system conditions listed In section 8. of this report. A Section Xi VT-3 Visual Examination of the affected component support was performed prior to the system belna returned to service. A Section Xi Surface Examination of the affected component was oerformed to satisv Section Xl Pre-Service Requirements. Code Case N-416-2 was Invoked to satisfy Section XI required oressure tests. Addtlonal Section IlIl Examinations were performed fas applicable) to satisfy Code Case N-416-2 and Rea.Guide 1.147.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Renalr/Repfacernent conforms to the rules of the ASM Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H. Ballard Signed: ° Engineering Technician Date: 6/16/2004 Owner or Owner's Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period // -/3 -03 to 6-// " 5 , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XM.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

b00J4t4O4. Sp4k1e Ait ,I,2.

Ar AdVUJ?_Zt I s Commissions: AOld 963 / / Alm)I //7/J 4A //

69 -

6'-~ 1/-0Z/ Nai 2a B r ,7 aX an Endorse ment ao Inspectoes sigatr National Board, State, and Endorsements Date: 6;- / ^7 200 VIsr

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xi

1. Owner: Calvert Cliffs Nuclear Power Plant, Inc. Date: 0113012003 (namne) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet I of 2 (add)ss)
2. Plan Calvert Cliffs Nuclear Power Plant Unit- One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2002-1-049b, MWO No. 1200202505 (add=s) (P.O. no, job no, ect.)
3. WorkPerformedby: Calvert Cliffs Nuclear Power Plant Dept. Type Code Symbol Stamp: Y (namc) Authorization No.: N/A Exp Date: M 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Sectio XI Class: Two (address)
4. IdentificationofSystem: SystemNumber 041 SystemName: Chemical Volume Control 5.(a) Applicable ConstructionCode and Class: ASME Draft Code for Pumps & Valves, 1968 EditIon, March 1970 Add; Class Two (b) Applicable SectXI Ed. for Repairs/Replacement 1998 Edition
6. Identification of Components Repaired or Replaced and Replacement Components: ASME Repaired, Code Name of Name of Manufacturers National Otiher Year Replaced,oi Stamped Componet Manufacturer Serial Number Board No. Identification Built Replacemm (Yes or No)

Valve Velan Engineering NIA #12 Charging Pump Discharge 1975 Repalred/Repl Yes Co. Isolation Valve sced Gate Valve Velan Engineering 90585-GX SN: NIA Valve, Gate, 2 In.1690 lb.; ASME 1994 Replacement Yes Co. 951075-1 SA-1S2 Tp. F316

7. Description of Work:

This plan was for the replacement of 1-HVCVC-172, #12 Charging Pump Discharge Isolation Valve.

8. Tests Conducted: HYdrostatic:Q PCumalicf Nominal Operating Pressure: bIservice: [1 Leakage:R FunctionaL 5 Pressure: 2300 psi. Test Temperature: 118 Deg. F NOTE: Supplemental sheets in fonn of lists, sketches, or drawings maybe used, provided (I) size is 8-1/2 in. x 11 in., (2) information in Items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form

- k7U Sheet2of 2 FORM NIS-2 (Back)

9. Remarks:

Code Case N-416-1 was invoked to satisfy Section Xi required Pressure tests. Addtlonal Section il Examinations were performed (as aDDlicable) to satisfv Code Case N-41-1 and Req.Gulde 1.147.

Applicable Manufacturer's Data Reports to be Atached Certificate of Compliance We certi dat the statements made in this report are corTect and that this Repair/Replacement confotmso the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate ofAuthorization No.: N/A Expiration Date: N/A 00 <Charles H.Ballard Signed: Engineerng Tchnician Date: 01/30/2003 Owner or Ownees Designce. rite I Certificate of Inservice Inspection I, the undersigned, holding a valid cormnission issued by the National Board of Boiler and Pressure Vessel inspectors and the Statepf Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components described in this Owner's Report during L.

, the period l 3 4 3/< to ;ZL2 / A9 and state to the best of my knowledge and belief, the Owner has performed exaninations and taken correctve measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XM.

By signing this certificate neither the Inspector nor his employer makes any wanrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report Furthennore, neither the Inspector nor his employer shall be liable in any mamer for any personal injury or property damage of a loss of any kind arising fkom or connected with this inspection

/f Commissions: PA z

  • iso6I d! S, 4A. 5**37 lnspectoeis Sigature National Board, State. ia Endorsements Date: 2.. t 20013

.V ri I -I

    • . ##^

il-;

DATA PACKAGE NO. _95075 P.7 FORM WPV.-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUmPS OR VALVES

  • An Required by the Provisions of the ASHE Code, Section 1U3, Division I Pa.

I of 2

1. manufactured and certt iled by VEIM ruNC. 2125 IWARD AVE. MTh. QXNADA m sad addess of N Cafiicakt Holder)
2. manufactured fos_ BALTIMORE GAS _- _& _ELECTRIC_ _ c , P.O._ BOX - _ 1472_ _ BALTYMORM.

, _ . .

  • Mfl ^ &2ii20v a
3. Location of installIon eVERT CIIFFS NUCLEAR PLANT NORTH OF LUSBY.

CA MD. 206S7 anmc nd adds)

4. Modal No., Series No., or Types -GATE Drawin P-76800-a22 Rev FL ciw CR.. _A
5. ASS Code, Section U!, Dirision Is a 1989 NOE- . /A (edito (addcnda date) (class) (Codcase Cm o.)
6. Pump or valve NAM Nominal inlet size 2 Outlet sire 2v M.) W
7. materials Body SA-182.F316 Boet SA-l82.F316 Disk SA-351.CFEM Bolting SA-54.,6o3 SA-194 .6 (a) (b) (C) (d) (e)

Cert. Nat' 1 Body Bonnet Disk Holder' a Board Serial Serial Serial Serial No. NO . No. No. No.

u51075-1 w N/A - I/Cl E-ER _ H/C: ADU - X/C ; 03R_

W

§9 75- .,

4' 91.


a- Wsg ass e~is S tflfls.

w= ==-

suppw=a lal rmation In frbm of =ss, wces, or drwaings may be Used provided (1) sIe I s 12 x I 1, (2)Inhformtln In Item: I trough4 on this Da Rep=o isIncjuded o each ,ee;(3) each shd Is sumbered and the number of ahee4 is recorded at t Itop of tld5 fbrm.

(12133) ThMfrm (E0037) may be obtained from te Order Dept, ASM, 22 L&W DBZVE< BOX 2300 Fairfield, M 07007-2300.

1.

0 ' ;t FORQ MV-1 (Back - Pg. 2 of 2 .7 Certificate Rolder's SBezrial No. 951075

8. Design conditions .100

_405S ps psi _ o valve pressure class or 1690 (1)

(PraUM) oacmnro))

9. Cold working pressure 405 , psi at 100?*
10. Bydrostatis teat _ 6350 psi. Disk differential teat pressure 46S0 pSi
11. Remarks s MATBRIALS ?MBBT ASMR SMCI N Il MDITIO: 1989 ADDENDA2 NXON CZRTZPICkU OP D3SS62 Design Specification certified by J.M. FARRBTJ P.Z. State OUR Reg. no. 30032 Design report certified by S. ____TSKY P.R. State _QgL_ Reg. no. 22125 CRRTI1ZCAT3 OP COMPLIANCE We certify that the statements made in this report are correct and that this pump or valve conforms to the rules for construction of the ASMB Code, Section IIU, Division 1.

N Certificate of Authorization No. . N-2797-1 REpires MAY 2.95 Date 2 N Zlame VULAN INC. Signed c v4.. =

(- -- OCmaCfa Holdv(* zcp=roseudh)

CZRTIPICATS OW INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of OUEBBC and employed by PROVIWCE of OUEBRC! have inspected the pump, or valve, described in this Data Report on -- o- Z.F , and state that to the best of my knowledge and belief, the Certificate Holder has constructed this pump, or valve, in accordance with the ASME Code,Section III, Division 1.

By signing this certificate, neither the inspector nor his employer makes any warrenty, expressed or implied, concerning the component described in this Data Report.

Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with thia inspection.

Date 2- Si-°z-.

ssgn 9 s___Cosml ons

'ozc0t (Ki. Rd. ancL wdorment) ad s'ats ogpQCm.ad o)

(1) For manually operated valves only.

RAYMOND LA'C.;CN D RPtIE OU aArMENTsLu C'J£3,C

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xi

1. Owner Caivert Cliffs Nuclear Power Plant, Inc. Date: 0113012003

(_M) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet 1oftL

... (addrss)

2. Plant .Caivert Cliffs Nuclear Power Plant unit.. One (name) 1660 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2002-1-049c, MWO No. 1200202505 (address) (P.O. nojob no, etc.)

Type Code Symbol Starop: NIA

3. WorkPerformedby: Cavert Cliffs Nuclear Power Plant Dept. Authorization No.: ;Q, (name)

Exp Date: NIA 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section Xl Class: Two (address)

4. Identification of System: SystemNumber 041 SystemName: Chemical Volume Control 5.(a) Applicable Construction Code and Class: ASME B31.7 1969 Edition, Summer 1971 Add; Class Two (b) Applicable Sect XI Ed. for Repairs/Replacement -

1998 Edition

6. Identification of Components Repaired or Replaced and Replacement Components: -. -

- -Repaired, Code Name of Name of Manufacturers National Other Year Replaced, ot Stamped Componet Manufacturer Serial Number Board No. Identification Built Replacemer (Yes or No)

Piping System Bechtel NIA N/A f12 ChargIng Pump Discharge 1975 -RepalredtRepl No Piping aced Pipe Consolidated 20439 HeatN 447/ NIA PIpe, 2 In.Sch. 160, ASME SA- 1998 Replacement No Power Supply XBJ 376Tp.316 Reducer Insert Ladish Co. FP8588 Heat Code: N/A Reducer, Insert. 2 In. X 3/4 In, 1973 Replacement No D6MC Hl ASME SA-182, Gr. F316, Socketweld, 6000 lb.

Tee DcBose National 54906-GX Heat N/A Tee, 2 In., 6000 lb., ASME SA- 1992 Replacement No Energy Services Code: RV 112, Tp. F316, Socket Weld Inc.

Pipe Strap Anvil Internatonal 34757 N/A Strap, Pipe Guide, 2 In, Part# 2 1999 Replacement No Inc. (Grinnell Pipe of PG-44 en Drwg.# FSK-MP-Supports) 0S71SH 005 &6 Elbow Consolidated 408879 Heat Code: N/A Elbow, Pipe, 2 In., 45 Deg, 6000 2002 Replacement No Power Supply MA lb, Socketweld, ASME SA-12, Gr. F316

7. Description of Workc This plan was for the use of the parts listed herein to support the replacement of 1-HVCVC-172, #12 Charging Pump Discharge Isolation Valve. This plan also covers any work on supports/hangers needed to support this work.
8. Tests Conducted. Hydrostatic:o Pneumatico Nominal Operating Pressure: Inservice: Ol Leakage. O Functional C3 Pressure: 2300 psi. Test Temperature: 118 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-l/2 in. x I I in, (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet:kof a FORM NIS-2 (Back)

9. Remarks:

Code Case N-416-1 was Invoked to satisfy Section XI required Pressure tests. Addtional Section III Examinations were oerformed (as apalicable) to satisfy Code Case N-416-1 and Rea.Guide 1.147.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance _ _ __ _

W certi that the statements made in this report are correct and that tis ReoallRenlacemnt conoms to the rules of the ASME Code,Section XI.

Type Code Symibol Stamp: N/A Certificate ofAuthorization No.: NIA Expiration Date: N/A Charles H.Ballard Signed: Engieering Technician Date 01/30/2003 Owner or Owne sDesl ne;Titfe

. .. Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectoms and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components descnbedin ffiis Owner's Report ding the period /64 /I.2. -to _2j//o3 , and state to the best of my knowledge and belief, the Owner has performed examinations and taken correctve rrteasureu described in this Owner's Report in accordance with the requirernents of the ASME Code, Section XL By signing this certificate neither the Inspector nor his employer makes any wamnt, expressed or implied, concerning the examinations and corrective measures described in this Owner's ReporL Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal inxury or property damage of a loss of any kind arising forn or connected with this inspection.

/7h sx )(3 Comnmissions: A20? ZoS- 19 4 I tJ'4 fliA 37Z Lnspetoes Signature National Board, State, and Endorsements Date: 200

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xl

.O Calvert Cliffs Nuclear Power Plant, Inc. Date 0810412003 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet I of 2 (address)

2. Plant Calvert Cliffs Nuclear Power Plant Unit One (nae) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2002-1-033, MWO No. 1200202602 (address) (P.O. no.job no., etc.)
3. WorkPerformedby. Calvert Cliffs Nuclear Power Plant Dept Type Code Symbol Stamp: N/A (name) Authorization No.: NIA Exp Date: N 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class: One (address)
4. Identification of System: SystemNumber 064 SystemName: ReactorCoolantSystem 5.(a) Applicable Constuction Code and Class: ASME B&PV Code Sect. III, 1983 Edition, Summer 1983 Add; 5is

`s- -i (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition

.6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired, Code Name of Name of Manufacturers National Other Year Replaced, o0 Stamped Componet Manufacture Serial Number Board No. Identification Built Rcplacemen (Yes or No)

RCP Seal Sulzer Bingham SN: 1C870 NB 1290 #11B Reactor Coolant Pump 1988 RepalredtRepl Yes Inc. Mechanical Seal. aced Seal BCE CCNPP Shops 1199901394 SN: NIA Seal, Cartridge Assembly (RCP) 1999 Replacement Yes 1864 875 i Complete Sulzer Bingham per FCR £740074

7. Description of Work This plan was for the replacement of the mechanical seal on #11 B Reactor Coolant Pump
8. Tests Conducted. Hydrostatic:[ Paeumaticf Nominal Operating Pressure: Inseice: C] Leakage: 2 Functional:;

Pressure: 2250 psi. Test Temperature: A28 Deg. F NOTE: Supplemental sheets in form oflists, sketches, or drawings may be used, provided (1) size is S-112 in x 1I1 in., (2) information in Items I through 6 on this report is included on each sheet, and (3) each sheet is mbhered and the nunber of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section Xi System Leakaae Test of the affected component was performed durina the system conditions listed in section 8. of this report Applicable Manufacturers Data Reports to be Attached Certificate of Compliance ______

We certify that the statements made in this report are correct aCd that this Revafr/Renlacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A CertificateofAuthorizationNo.: N/A ExpirationDate: N/A Charles H.Ballard Signed: Engineering Technician Date: 08/04/2003 Ower fwe nscsg, Tidle Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by AB§ Consulting of Houston, Tx. ave inspected the components descrnbed in this Owner's Report during the period _ -7 3 to t / xI okw . andstatetothebestofmy knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report Fbrthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any Idnd arising from or connected with this inspection.

7 (z4 q Commissions:A/atf/ o2/ 8 1/3 AAB2WDi

, inspectoes Sigature National Board, State, and Endorsements Date: if / St 200 3

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xi

1. Owner: Calvert Cliffs Nuclear Power Plant, Inc. Date: 1210312003 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet I of 2 (address)
2. Plant: Calvert Cliffs Nuclear Power Plant Unit One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2002-1-050a, MWO No. 1200202689 (address) (P.O. no., job no., etc.)

Ipt. Type Code Symbol Stamp: N/A

3. Work Performed by: Calvert Cliffs Nuclear Power Plant Di Authorization No.: N/A (name)

Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class: Two (address)

4. Identification of System: System Number 041 SystemName: Chemical Volume Control 5.(a) Applicable Construction Code and Class: ASME Draft Code for Pumps & Valves,1968 Edition, March 1970 Add; Class Two (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition
6. Identification of Components Repaired or Replaced and Replacement Components: ASME Repaired, Code Name of Nane of Manufacturers National Other Year Replaced, oi Stamped Componet Manufacturer Serial Number Board No. Identification Built Replacemen (Yes or No)

Valve Velan Engineering 1-CKVCVC-171 N/A #12 Charging Pump Discharge 1975 Repaired/Rep! Yes Co. Check Valve aced Check Valve Velan Engineering 90585-GX SN: N/A Valve, Check, 2 In, 2680 1994 Replacement Yes Co. 951037-1 Ib.,Socketweld, SA-182, Tp F316, BGE Dwg 12968-0138

7. Description of Work:

This plan was for the replacement of 1-CKVCVC-171, #12 Charging Pump Discharge Check Valve.

8. Tests Conducted: Hydrostatic:[ PneumaticO Nominal Operating Pressure: Inservice: E Leakage: i Functional: E Pressure: 2320 psi. Test Temperature: 112 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) information in Items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section Xl System Leakage Test of the affected component was performed during the system conditions listed in section 8. of this report. Code Case N-416-1 was invoked to satisfy Section Xl required pressure tests. Addtional Section III Examinations were performed (as applicable) to satisfy Code Case N-416-1 and Rea.Guide 1.147.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this RepafrlReplacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H. Ballard Signed: c - Engineering Technician Date: 1V03/2003 Owner or Owners ignee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period to , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

Commissions: It,9P3/0`31 A I.9 /117/

Insoector's Signature National Board, State, and Endorsements Date: 4', q200 -3

DATA PACrAGH NO.- 951037 P.6 rt 5'DATA REPO LAR P OVAES

. --- C -9 Pg. I of, 2

1. Kanufactured and certified by YVEhAN INC. 2125 WARD AV_. MTL. CANADA (name and address of F Ceruificate Holder)
2. Manufactured for BALTIMORE GAS & ELECTRIC 'P.O. BOX 1472 BALTIMORE, MD. 21203 (name and address of purchiser)
3. Location of installion CALVERT CLIFFS NUCLEAR PLANT NORTH OF LUSBY. MD. 20657 (rame and address)
4. Model No., Series No., or TQpes PS.CECK Drawing P1-76800-K28 Rev D CRN N/A
5. ASME Code, Section III, Division It 198S NONE 1 NTA (editlon) (addenda date) (CUass) (Code Case no.)
6. Pump or valve VALVE Koinal inlet size 20 Outlet size 20
7. Materials Body SA-182.F316 Bonnet SA-182,F316 Disk COLMONOY 4 Bolting N/&

(a) tb) (C) td) *(e)

Cert. Nat' 1 Body Bonnet Disk Holder ' s Board Serial Serial Serial Serial No. No. No . NO . . No.

951037-1 N/A H /C : CH H/Ce 1AR.A H/C: 2072 951037-2 U I, a

a .

U

_ 951037-3 nfl--a--a----_ I9 ff .3?

N...

Supplemental Information in fbrn of Usts, iketches; or drawings may be used provided (1) ize is S 1/2 x I1, C2) Infornation In Itemns I through 4 on this Data Repoet Is Included on tact sheet, (3) each shee Is numbered and the number of sheets Is recorded at the top of Ihis form.

(12/88) MIs form (500037) may bc obtaine from the Order Dept., ASME, 22 LAW DRI <E<BOX 2300 Fairfield, NJ 07007-2300.

PORQ PV-1 (Back - Pg. 2 of 2 P.7 S. Dexign conditions 6430 psi 100 OF or valve pressure class 2680 (1)

(preaxr) ACmperd)

9. Cold working pressure 6430 psi at 1007Y
10. Hydrostatic test 10050 psi. Disk differential tes~t pressure 7375 psi
11. Remarkas MATERIALS MEET ASMa SECTION II EDITIONS 1989 AMDDENDA: NONE CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this pump or valve conforms to the rules for construction of the ASME Code,Section III, Division 1.

N Certificate of Authorization No. N-2797-1 __xPirs -MAY 2_98 Date MAY 2 61995 Name VELAN INC Signed __

(N Certificate. Holder) A (autbov se3aZrve)

'1 CERTIFICATE OF INSPECTIOR I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of OUBBMC and employed by PROVINCE of OUEBEC have inspected the pump, or valve, described in this Data Report on 4-Y,- 4& , and state that to the best of my knowledge and belief, the Certificate Holder has constructed this pump, or valve, in accordance with the ASME Code,Section III, Division 1.

By signing this certificate, neither the inspector nor his employer makes any warrenty, expressed or implied, concerning the component described in this Data Report.

Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Date 925- signOS'2' - Commissions _

rhoried Inspo0) (Natel d.Od.endorsmmnt) and stats or prov. and no.)

(1) For manually operated valves only. RAYMOND LAUZON Q PMGI3 DU ATIMENTMTDOUA.o

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xl

1. Owner: Calvert Cliffs Nuclear Power Plant, Inc. Date: 11/06/2003 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657. Sheet i of 2 (address)
2. Plant: Calvert Cliffs Nuclear Power Plant Unit: One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2002-1-050b, MWO No. 1200202689 (address) (P.O. no., job no., etc.)

Type Code Symbol Stamp: N/A

3. WorkPerformedby: Calvert Cliffs Nuclear Power Plant Dept. Authorization No.: N/A (name)

Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class: Two (address)

4. Identification of System: System Number 041 System Name: Chemical Volume Control 5.(a) Applicable Construction Code and Class: ASME B31.7 1969 Edition, Summer 1971 Add; Class Two (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 EditIon
6. Identification of Components Repaired or Replaced and Replacement Components: ASME Repaired, Code Name of Name of Manufacturers National Other Year Replaced, oi Stamped Comnponet Manufacturer Serial Number Board No. Identification Built Replacemen (Yes or No)

Piping System Bechtel 2" CC-7-1002 N/A #12 Charging Pump Discharge 1975 Repaired/Repl No Piping aced Pipe Consolidated 20439 Heat# 447 N/A Pipe, 2 In., Sch. 160, ASME SA- 1998 Replacement No Power Supply 376, Tp. 316 Tee DuBose National 54906-GX Heat N/A Tee, 2 In., 6000 lb, ASME SA- 1992 Replacement No Energy Services Code: BV 182, Tp. F316, Socket Weld Inc.

Insert Reducer Ladish Co. F-8588 Heat Code: N/A Reducer, Insert, 2 In. X 3/4 In., 1973 Replacement No D6MC H1 6000 lb., Socketweld, ASME SA-182, Gr. F316

7. Description of Work.

This plan was for the use of the parts listed herein to support the replacement of 1-CKVCVC-171, #12 Charging Pump Discharge Check Valve. This plan also covered work on supports/hangers needed to support this work.

8. Tests Conducted: HydrostaticO PneumaticCj Nominal Operating Pressure: Inservice: 0 Leakage: i Functional: C]

Pressure: 2320 psi. Test Temperature: 112 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x I 1 in., (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section XI System Leakage Test of the affected component was performed during the system conditions listed in section 8. of this report. Code Case N-416-1 was invoked to satisfy Section Xl required pressure tests. Addflonal Section III Examinations were Performed (as applicable) to satisfy Code Case N-416-1 and-Req.Guide 1.147.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Repair/Replacement conforms to the rules of the ASME Code,Section X.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: NIA Charles H.Ballard Signed: Engineering Technician Date: 11/06/2003 Owner or Oirne~sVesinei, Title`

Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period_ to - and state to the best of my knowledge and belief; the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

_y p4 - -

Commissions: ?Ad q3 /,4O Z . , .

Alq1L/L?

// AlInspector's Signature National Board, State, and Endorsements Kate: Im 3 200 -3

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xi

1. Owncr Calvert Cliffs Nuclear Power Plant, Inc. _ Date: 101312003 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet of 2 (address)
2. Plant: Calvert Cliffs Nuclear Power Plant Unit: One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2002-1-051, MWO No. 1200202762 (address) (P.O. no., job no., etc.)

ept. Type Code Symbol Stamp: N/A

3. Work Performed by: Calvert Cliffs Nuclear Power Plant DE Authorization No.: N/A (name)

Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section Xl Class: One I (address)

4. Identification of System: System Number 064 System Name: Reactor Coolant System 5.(a)ApplicableConstructionCodeandClass: ASMEB31.1.0 1967Edition,CCasesN-2,N110 -.

(b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition

6. Identification of Components Repaired or Replaced and Replaceint Components: ASME Repaired, Code Name of Name of Manufacturers National Other Year Replaced, oi Stamped

. Comnponet Manufacturer Serial Number Board No. Identification Built Replacemen (Yes or No)

Valve ITT Hammel Dahl 69-4126-002 NIA 11 lBPressurizerSprayCuitrol 197S Repalred/Repi No Valve ' ed Bonnet Flowserve 400322 SN; D909A- NtA Bont!i, Bellows, 3 In. 1500 lb. 2000. Replacement No Corporation 1-1 ITT Hammel-Dahl Angle Valve, Drwg. #12121-0006, Item 02 -

Pipe Cap Dulose National 10486-GX Heat NMA Cap, Pipe, 12 InI, 300Q lb. SW, 1996 Replacement No Energy Services Code: HTK ASME SA-482, Tp. 316 Inc.

Plug Neles Jamesbory 56479-GX SN: N/A Plugtor3 In.1500 lb.ITT 1991 Replacement No R1613-1 IHanid-Dabl Angle Valve, Drwg.

N1212140006, Item 16

7. Description of Work:

This plan was for the rebuilding and replacement of the Bonnet and Plug on 1-CV-100F, which is #11B Pressurizer Spray Control Valve.

8. Tests Conducted: Hydrostatic:Q Pncunaticl Nominal Opaating Pressure: Inservicc: 0 Lkahgc: 0 Functional: 0 Pressure: 2250 psi. Test Temperature: 532 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x II in., (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:.

A Section Xi Svstem Leakace Test of the affected component was Derformed durino the system conditions listed in section 8. of this report. A Section Xl Surface Examination of the affected component was Derformed to satisy Section Xi Pre-Service Requirements.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance ______

We certify that the statements made in this report are correct and that this Revalr/Renlacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H. Ballard Signed: __ Engineering Technician Date: 10/3/2003 Owner or Ownces Designee, Title Certificate of Inservice Inspection 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period to //-/s- dL,. 6,: and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthernore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

1

  • Commissions: A/A, 7 11 3 421 //6W 44/AT nspectoe's Signature National Board, State, and Endorsemenpq, Date 'AC S0 [AK 200 -

O ___ _

. is.  ;

FORM NIS-2 OWNER'S FEPORT FOR REPAIR / FKEPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner: Calvert Cliffs Nuclear Power Plant, Inc. Date: 6115/2004 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet I of 2 (address)
2. Plant: Calvert Cliffs Nuclear Power Plant Unit: One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-046a, MWO No. 1200203109 (address) (P.O. no., job no., etc.)
3. Work Performed by: Calvert Cliffs Nuclear Power Plant Dept. Type Code Symbol Stamp: N/A (name) Authorization No.: N/A Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class: Two (address)
4. Identification of System: System Number 052 System Name: Safep nection 5.(a) Applicable Construction Code and Class: ASME Draft Code for Pumps & Valves,1968 Editlon, March 1970 Add; Class 2 (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition
6. Identification of Components Repaired or Replaced and Replacement Components: ASME Repaired, Code Name of Name of Manufacturers National Other Year Replaced, oi Stamped Componet Manufacturer Serial Number Board No. Identification Built Replacemen (Yes or No)

Valve Velan Enginnering 1-CKVSI426 N/A #13 High Pressure Safety 1975 Repalred/Repl No Co. Injection Pump Mini Flow Check aced Valve CheckValve Enertech Inc. 411160 SN: 11319 N/A Valve, Nozzle Check, 2 In, 1500 2004 Replacement Yes lb, Enertech KRV, Body SA-479, Tp. 316, Disc SA-564, Tp.

6301H1075

7. Description of Work:

This plan was for the work needed to replace 1-CKVSI-426, #13 High Pressure Safety Injection Pump Mini Flow Check Valve.

8. Tests Conducted: Hydrostatic:Fj Pneumatic: Nominal Operating Pressure: Inservice: f Leakage: j Functional: E Pressure: 1310 psi. Test Temperature: 82 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

as ---- % *v Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section Xl System Leakaae Test of the affected component was performed during the system conditions listed in section 8. of this report.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Revalr/Reolacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A K A Charles H.Ballard Signed: gineering Technician Date: 6/15/2004 Owner or Owne' Designee, Ttle I Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period _aA3 Ok to '- 9S-9 Aand state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

bco4J1D A, SW U1M fo& fe-ionjfJ sejoeads Pt. ZYKE-fAi Commissions: N6 98 3/ ,O1 //7X, 4A /

u 9B N ai77 /Sa, nd

, Insoector's Signature National Board, State, and Endorsemnents Date: 6' - f/& 200 -

N1

FORM NPV;1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES*

  • . .. As Required by the Provislons of-the ASME Code,Section III, DIvi8ion I

.. *. .. .. .Pg.1of 2

1. Manufactured and ceified'by Enertech, A Div. of Curtiss-Wdght Flow Control Corp., 2950 Birch St., Brea, CA 82821 (name and address of N Certificate Holder)
2. Manufactured for Calvert Cliffs Nuclear Power Planit, PO Box 17323. Baltimore, MD 21297-1323 haine and address of Purchaseri
3. Location of Instalan Calvert Cliffs nuclear Power Plant; 1650 Calvert Cliffs Parkway, Lusby, .MD.206S7.

(name an4 iddress:

4. Model No., Series No., or Typ KRV Drowing MD21083 Rev. A None S. ASME Code,Section III; Division t: 1995 1996 2 .None (edition) (addenda date) Iless) ICode Case no.)
6. Pump or valve NNorhini Inlet size . 2 Outlet size

((in.)

7 MateIal Bdy SA-479Type316 Sonnet N/A Disk US-564Tiye30H1075 Bolting .

(b .. . .. . (c (al Wb (cW d (el Cert. Nat' I Body Bonnet Disk.

Holder's Board Serial Serial Serial Serial No. No. No. No. No.

11311 None . KTV-3327 None KITW-3335 11312 None KTV-3328 None KTW-3336 11313 None KTV-3329 None... 'TW3337 .

11314 None . KTV-3330 .None - KTW-3338 11315 Nne-. KTV-3331 None . KTW-3339 11316 None* KTV-3332 . None . ITW-3340

  • 11317 None .* KTV-3333 . None ' .; T..K:FW-3341 11318 . - None KTV-3334 None KTW-3342

_ _ .7 Supplemental Information In form of lsts, sketches, or drawings may be used provided (1) size Is B X x I1I, (21 Informatioe in Items I through 4 on this Data Report Is included on each sheet, 13) each sheet Is numbered and the number ef sheets Is recorded at the top of this for3n.

(12/88) This form lEOWO371 may be obtained from the Order Oept., ASME, 22 Law Drive, Box 2300, Fairfield, NJ 07007.2300. REPFUNT U93

FORM NPV-t (Bock - Pg. 2 of 2..

11311 thru Ce'rtificate Holder's Serial No. 11318

.8Design conditiona 1600 psi 30 F or valve pressure class 1500 (pressure) . Itemperaturel

9. Cold working pressure 3600 psl at tOOF
10. Hydrostatic test - 5400 psi.. Disk differantial test pressure N/A _

-. i px-I 1: Rlemarks: Qty. 8, Enertech Project Number 810048 CERTIFICATION OF DESIGN Design Specification certifted'by John R. Sponsel, I P.E. State MD Reg. no. 17308 Design Report certified by Ira J, Silverman P.E. State CA Reg. no. 23241 I

CERTIFICATE OF COMPLIANCE We certify that the statements made In this report are correct and that this pump or valve conforms to the rules for construction of the ASMi Code, Section lIl. Division 1.

N Certificats of Authorization No N2826E

.1 bate

1. 1 .

Edt A Div. of Curtfss-Wwfght Flow Corrro Cbrp.

INCertificate fHolder)

Big (authorizud represntatv I

CERTIFICATE OF INSPECT1iON

.1,the undersigned. holding a valid commission Ipssued by the National Board of Boller and Pressure Vessel Inspectors and the StatS or Province of Calaforia end employed by HSB CT of Connecticut . have Inspected the pump, or valve, described In thisflita Report on

. 1 - Zq 4~* - !and stats that to the best of my knowildge and belief, the Certificite Holder has con-structed this pump, or valve, In accordance with the ASME Code, Section ill, Division 1.

By signing this certificate; neither the Inspector nor his employer mekei any warranty, expressed or Implied, concerning the component described in this Data Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any klhd aIsIng from or connected with this Inspection.

Date / 42I3igned mLissona 14q4-lAuthorized Inspector) [Nat'l. 8d. (Incl. endorsements) and state or prov. and no.)

(11 For manua'ly operated valvesvonly.

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl

1. Owner: Calvert Cliffs Nuclear Power Plant, Inc. Date: 611512004 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet I of 2 (address)
2. Plant: Calvert Cliffs Nuclear Power Plant Unit: One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-046b, MWO No. 1200203109 (address) (P.O. no., job no., etc.)
3. Work Performed by: Calvert Cliffs Nuclear Power Plant Dept. Type Code Symbol Stamp: N/A (name) Authorization No.: N/A Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class: Two (address)
4. Identification of System: System Number 052 SystemName: Safety Injection 5.(a) Applicable Construction Code and Class: ASME B31.7 1969 Edition, Sum. 1971 Add; Class 2 (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition
6. Identification of Components Repaired or Replaced and Replacement Components: ASME Repaired, Code Name of Name of Manufacturers National Other Year Replaced, oi Stamped Componet Manufacturer Serial Number Boaard No. Identification Built Replacemen (Yes or No)

Piping System Bechtel 2"DC-2-1003 N/A #13 High Pressure Safety 1975 Repaired/Repi No Injection Pump Mini Flow Recirc. aced to Refueling Water Tank Pipe Albert Pipe Supply F-5630 Ht.#: 496481 N/A Pipe, 2 In., Sch. 80, ASME SA- 1970 Replacement No Co. Inc. 376, Tp. 304 Nut Mackson Inc. 408227 Ht.#: S44018 N/A Nut, Heavy Hex, 7/8 In. X 9 TPI, 2002 Replacement No ASME SA-194 Cr. 2H Allthread Rod Mackson Inc. 410155 Ht.#: S20751 N/A Rod, Aulthread, 7/8 in. X 9 TPI, 2003 Replacement No ASME SA-193 Gr. B7 Flange DuBose National 411588 Ht.#:31438 N/A Flange, 2 In., 1500 lb., Raised 2003 Replacement No Energy Services Code: BQL Face, Socketweld, ASME SA-182, Inc. Gr. F316 Nut Mackson Inc. 400066 Heat Code: N/A Nut, Heavy Hex, 7/8 In. X 9 TPI, 2000 Replacement No JKX ASME SA-194 Gr. 2H

7. Description of Work:

This plan was for the piping, fittings, hanger support work and fasteners needed to support the replacement of 1-CKVSI-426, #13 High Pressure Safety Injection Pump Mini Flow Check Valve.

8. Tests Conducted: Hydrostatic:n PneumaticO Nominal Operating Pressure: Inservice: E Leakage: R Functional: n Pressure: 1310 psi. Test Temperature: 82 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section Xi Svstem Leakage Test of the affected comoonent was performed durina the svsteml conditions listed in section 8. of this report. Code Case N-416-2 was invoked to satisfv Section Xl required pressure tests. Addtional Section III Examinations were performed (as applicable) to satisfy Code Case N416-2 and Rea.Guide 1.147.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this RepalrlReplacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H. Ballard Signed: V Engineering Technician Date: 6/15/2004 Owner`r (iwnes Designee, Title i' Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period .2.23 04 to C- M- O., and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

bLordL A. 5 N-71A rY AlIz.

5-04J AMvJ6IS PM a -o -A( Commissions: AXJ3 &'3/, /10 /7/ 71 4 /1

,vi JA. -77'e D Inspector's Signture National Board, State, and Endorsements -

Date: 6v- 14 200

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xl

1. Owner:

Calvert Cliffs Nuclear Power Plant, Inc. Date: 6/15/2004 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet I of 0 (address)

2. Plant: Calvert Cliffs Nuclear Power Plant _ Unit: One (name) 1650 Calvert Cliffs Parkway; -Lusby, MD 20657 R&R No. 2003-1-056, MWO No. 1200203364 (address) (P.O. no.,job no., etc.)

Type Code Symbol Starmp: N/A

3. Work Performed by: Calvert Cliffs Nuclear Power Plant Dept.

Authorization No.: N/A (name)

Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class: One (address)

4. Identification of System System Number 064 SystemName: Reactor Coolant System 5.(a) Applicable Construction Code and Class: ASME B&PV Code Sect. III, 1968 Edition, Win. 1968 Add; Class A, CCases N-2, N-10 (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition
6. Identification of Components Repaired or Replaced and Replacement Components: ASME Repaired, Code Name of Name of Manufacturers National Other Year Replaced, oi Stamped Componet Manufacturer Serial Number Board No. Identification Built Replacemen (Yes or No)

Valve Dresser Industrial SN: BM-07953 N/A Unit One Pressurizer Safety 1977 Repalred/Repl Yes Valve Co. Relier Valve aced Nozzle Consumer Power 06045-GX AAA26 N/A Nozzle, Maxiflow Relier Valve, 2 1987 Replacement Yes Co. (Midland Plant 1/2 In., Model 31739A, Dresser Project) P/N 4231701N, ASME SA-182 Gr.

F347 Relief Valve Dresser Industries 411829 SN: BN- N/A Valve, Consolidated Closed 2004 Replacement Yes Inc. 04373 Bonnet Maxlflow Safety; 2-1I2 In.

Mode! 31739A, only for RV 200 4dDK & location.

Disc Dresser Industries 409135 SN:*915F 6 N/A Disc, Maxillow Relief Valve, 2 1/2 2003 Replacement Yes Inc. In., Model 31739A, Dresser P/N 1840404N, ASME SB-637 Gr. 688 ReliefValve Consumer Power 06045.GX AAA19 N/A Cannibalized pressurizer relief 1987 Replacement Yes Co. (Midland Plant valve, SIN BN 04376 Project)

7. Description of Work:

This plan was for the replacement of Unit-1 Pressurizer Safety Valve, 1-RV-200.

8. Tests Conducted: Hydrostatic:n PneumaticG Nominal Operating Pressure: Inservice: l Leakage: i Functional: 0 Pressure: 2260 psi. Test Temperature: 660 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 1I in., (2) information in Items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

i -

r 0-56~-Sheetaof ~..

c'36FORM NIS-2 (Back)

9. Remarks:

A Section XI VT-1 Visual Examination of the replacement threaded fasteners was performed to satisfy Section Xl Pre-Service NDE Requirements. A Section Xl System Leakaae Test of the affected component was performed during the system conditions listed in section 8. of this report.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Repalr/Reolacenent conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A i dI/ *7v Charles H. Ballard Signed: Engineering Technician Date: 6/15/2004 er or Ownes Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described inthis Owner's Report during the period 3 30-0' to 4_-__-__and

_ state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described- in this Owner's Report in accordance with the requirements of the ASME Code, Section )[.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

D044LD A Se-/IA (tvL AU?.

DoffsSH jeiL2 S PrL T7-1741 Commissions: Ak3 '7g31 1 1/17/1 AJ  ; yL'-?7 M

/AU' _5 Insnectores Signature National Board, State, and Endorsements Date: --/ 7 - 200.

FORM NVR-1 REPORT i tEPAIR [Z MODIFICATION i OR REPLACEMENT ]

OF NUCLEAR PRESSURE RELIEF DEVISES

1. Work performed by Dresser Flow Control, Dresser Inc. La. Hwy 3225 @ Us Hwy 167 N 4118291408989 01287030101284080

( name of organization) (P.O. no., job no., eta)

P. 0. Box 1430 Alexandria, Louisiana 71309-1430 (address)

2. Work performed for Baltimore Gas & Electric Co. 1650 Calvert Cliffs Parkway Lusby, Maryland 20657

( name and address )

3. Owner Baltimore Gas & Electric Co. 1650 Calvert Cliffs Parkway Lusby, Maryland 20657 (name)

(address)

4. Name, address and Identification of nuclear power plant Baltimore Gas & Electric Co. Calvert Cliffs Nuclear Station 1650 Calvert Cliffs Parkway Lusby, Maryland 20657
5. a: Repaired pressure relief device: Safety Valve b: Name of manufacturer Same as item 1 above c: Identifying nos. 31739A BN-04373 N/A STEAM 2-1/2" 1977 (type) (mrs serial no.) (Nat'l. Bd. No.) (service) (size) (yearbultt) d: Construction Code ASME Section III 1968 Winter 1968 W 1968 Art. 9 A (name/section/division) (edition) (addenda) (Code case(s)) (Code Class)
6. ASME Code Section Xl applicable for in service inspection: 1998 NO NONE (edition) (addenda) (Code Case(s))
7. ASME Code Section Xl used for repairs, modifications, or replacements: 1998 NO NONE (edition) (addenda) (Code Case(s))
8. Construction Code used for repairs, modifications, or replacements: 1968 W 1968 Art. 9 NONE (edition) (addenda) - (Code Case(s))
9. Design responsibility Same as item 1 above
10. Opening pressure: 2485 PSIG Blowdown (if applicable) N/A  %. Set pressure and blowdown adjustment made at: Wyle Laboratories, Huntsville, Alabama Using Steam

-lcataon (test medium) i 1. Description of work: (include name and identifying number of replacement parts) Valve Was Disassembled, Inspected, Repaired Assembled, & Tested. Parts Replaced: Base P/N 1861505NC2015,S/N AAA-19; Nozzle PIN 18448060S278,SIN AAA26; Bellows PIN 1840801N, SIN 2872/2-2; Disc PIN 1840404N, S/N ADK-59; Guide/Support Plate Gaskets PIN 3831018N, Cotter Pins P/N 2220219, & Adi. Ring Pin Gaskets PIN 3610508.

12. Remarks: Base was modified on owner's purchase order 411554, Dresser order no. 31-52548-0.

CERTIFICATE OF INSPECTION I, P.-W.l a ) A / - certify that to the best of my knowledge and belief the statements made in this report are Correct and the repair, modification or replacement of the pressure relief devices described above conforms to Section Xl of the ASME Code and the National Board Inspection Code 'VR' and 'NR' rules.

National Board Certificate of Authorization No. VR-70,95,97-118 & 12G-124 to use the 'VR stamp expires 6-29-2004 National Board Certificate of Authorization No. NR-45 to use the M Ra stamp expires 630-2005 Date  ;/t4 O ( Same as Item 1 above. Signed (name of certificate holder ) (authorized representive)le)

CERTIFICATE OF INSPECTION I, ,j k?,-f/OS,*4b, , holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors and certificate of competency issued by the jurisdiction of Louisiana and employed by Hartford Steam Boiler Inspection and Insurance Co. of Hartford, CT have Inspected the repair, modification or replacement described In this report on and state that to the best of my knowledge and belief, this repair, modification or replacement has been completed in accordance with Section Xl of the ASME Code and the National Board Inspection Code "VR' and

'NR' rules.

By signing this certificate, neither the undersigned nor my employer makes any warranty, expressed or Implied, concerning the repair modification or replacement described in this report. Furthermore, neither the undersigned nor my employer shall be liable in any manner for any personal injury, property damage or ss ao 8 nd arising from or connected with this inspection.

Date Signed Commissions .424= A lkb'LrcJ (National Board (i. endorsements),

iurisdiction, and no.1

FORM N-2 CERTIFICATE HOLDERS' DATA REPORT PuR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*

As Required by the Provisions of the ASME Code, Section Ill Not to Exceed One Day's Production Pg.Iof 2 Dresser Flow Control, Dresser Inc. La. Hwy 3225 @ US Hwy 167 N

1. Manufactured and certified by P. 0. Box 1430 Alexandria, Louisiana 71309-1430 (name and address of NPT Certificate Holder) _
2. Manufactured for Calvert Cliffs Nudear Power Plant P.O. Box 17323 820 G & E Building Baltimore Md 21297-1323 (name and addes of pwdhaser)
3. Location of installation Calvert Cliffs Nuclear Plant, 1650 Calvert Cliffs Parkway Lusby Md 20657 (nam andm address)
4. Type OS417 SB637 (Inconel X-750) 170 KSI NIA 2003 (drawing no.) (matl spec, no.) tensile strength) (CRN) ( yearbult)
5. ASME Code Section III, Division 1: 1968 - Winter 1968 1 N/A

( edition) (addenda date) (cdass) (Code Case no.)

6. Fabricated In accordance with Const. Spec. (Div. 2 only) NJA Revision N/A Date NIA (no)
7. Remarks: Serial Numbers Are Used In Ueu Of NPT Stamping.
8. Nom. thickness (in.) N/A Mi ndesign thickness (In.) NiA Dia. ID (ft. & In.) N/A Length overall ( ft & in.) N/A
9. When applicable. Certificate Holders' Data Reports are attached for each item of this report Part or Appurtenance National Serial Number Board No.

In Numerical Order (1) ADK59 (2)

(3) 4 (4) t (5) 4 (6)

(7)

(8)

(9)

(10)

(11)

(12) I (13) I (14) I (15) l (16)

(17)

(18) l.

(19)

(20)

(21) I.

(22) 1-(23)

(24)

(25)

10. Design pressure N/A psi Temp. N/A *F. Hydro. Test pressure 4500 PSIG at temp. OF
  • Supplemental information inthe form of lists. Sketches, or drawings may be used provided (1)sIze is 8-1/2 x 11, (2)information Initems 2 and 3 on this Data Report Is ninduded on each sheet. (3)each sheet isnumbered and the number of sheets is recorded at the top of this form.

4 1 FORM N-2 (Back - Pg. 2 of 2 )

Certificate Holder's Serial Nos. ADK59 and CERTIFICATION OF DESIGN Design specificaffons certified by NZA P.E. State N/A Reg. No. N/A (wten applicable)

Design report* certilled by NWA P.E. State N/A Reg. No. NIA (when applicable)

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this ( these) DISC conforms to the rules of construction of the ASME Code, Section Iii, Division 1.

NPT Certificate of Authorization No. N-2434 Expires _012004 Date 3/i 103 Name SEE LINE I

{ NPT Certificate Holder)

Signed i*V W) I (authorized represewtattva)

CERTIFICATE OF INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province of LOUISIANA and employed by H.S. B. I.& i. Co.

of HARTFORD, CT. have Inspected these items described in this Data Report on 1/M o0k..I , and state that to the best of my knowedge and belief, the Certificate Holder has fabricated these parts or appurtenances Inaccordance with the ASME Code,Section III, Division 1.Each part listed has been authorized tor stamping on the date shown above.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or imptied, concerning the equipment desraibed in this Data Report. Furthermore, neither the Inspector nor his employer shall be gable Inany manner for any personal injury or property damage or loss of any kind arising from or connected witht p pecon.

Date 3 // Signed Al f Commissions _

-I f AMMaWM Mwf hp Imaectnr s I, I%NM.04 E 4 n e d,.-4 n, . zs an CRX o.-. .Go.svaw

}.-

- Se1w dn l e

I A el -. 71r 4c-k I DSO A'. 3ei FORM NV-I N CERTIFICATS HOLDERS' DATA REPORT FOR SAFETY AN4 SAFETY RELIEF VALVES*

(AS REQUIRED IT THE PROVISIONS OF THE ASKE CODE, SECTION III, DIV. 1)

1. RANUFACTURED if DRESSER INDUSTRIAL VALVE A IXSTR. DIV. Ml6Ayl7ft NOWMN ALEWDRIi. 1.603IfiANA (ANAEAND ADDRESS OF ItDRTI FICATE HOLDER)
2. MANUFACTURED FOR Babcock & Wilcox Pwr-Gen.Div.qP.0.Box 1260, Lynchburg, Va. 24505 CRNAE AND ADDAESS OF PURCHIASER 01 OWNER)
3. LOCATIOR OF INSTALLATION Cons~ers Power Co., Midland Unit 1, Midland, Mich.

(NAME AND ADDRESS) 4 - 4CP-243Z 258 1978 (CRAN) (BRAVING NO.) (AT'L IRO.HO.) (TEAR D9ILT3

5. VALVE 2 31739A-1-X2-0S278 ITENT41111NE So. BN04376 (MODEL DO..SERIES NO.) (N CERTIFICATIHQLDER5'1SEIIAL.NC-.)

TYPE Safety CLASS J (SAFETYSAFETY RELIEF;PILOT:POWER ACTUATED)

ORIFICE SIZE.. 1.& , SOMINAL INLET SIZE 21/2 CUTLET SIZE 6" IICH INCH INCII

0. SET PRESSURE (PStC) 2500 RATED TEMPERATURE 670 IDF STAMPED CAPACITY 297.845 L!S/HR.
  • 3  % OVERPRESSURE SLOWDOWN (PSIG) 125 SAT.STEAM HYDROSTATIC TEST (Psi) INLET 3750 -SIG OUTLET 1050 PSIG (APPLICASLE TO VALVES FOR CLOSED SYSTEMR' HLY]

T. PRESSURE RETAINING PIECES SERIAL IN. OR MATERIAL SPECIFICATION.

IDENTIFICATION INCL. TYPE OR GRADE SODY B/A/AAAIS SA-182 Gr. F316 SONNET 1Zffsx== B/AR/AAA40 SA105 SUPPORT RaOS NOZZLE TRIlIAAA26 SA-187 !Gr- r-347 eISC RjrjAAT~nq SA-6137 !Gr. figg SFRI19 WASHERS 15023 SA-105 ADIUSTINO SCREW M6356aSB-164 Class A SPINDLE t'17RR7 *SA--479 er- 147 SPARIN - -- AH1210 AISI H21 DOLTING OTHER PIECES ohtlct Elamse 79207 SA-182 Gr. F316 B^-^ -of, a M.14 SA_194 Gr. 21 - I

  • SUPPLEMENT SHEETS IN FORM OF LISTS.SKETCHES OR ORAWINOS MAY BE USED PROVIDED (I) SIZE IS 3-1/2"X II1 (2) INFORMATION IN ITEMS 1-2 0H THIS DATA REPORT IS INCLUDED ON EACH SHEET. AND (3) EACH SHEET IS NUNDERED AND NUMBER OF SHEETS IS RECORDED AT TOP OF THIS FORM.

_. , i , _,__

1S ;i j ;sIii '

FORM xWlI (SACX)

CERTIFICATE OF COMPLIANCE wl CERTIFY THAT THE STATEMENTS YADI IN THIS REPORT ARl CORRECT AND THAT THIS TALYI CONFORMS TO THE RULES OF CONSTRUCTION OF THE ASNE CODE FOR NUCLEAR PO1E1 PLANT COMPONENTS, SECTION III, DIV.I, 1971 EDITION. ADDENDA Sumer 1972 , CODE CASE N/A DATE 1-26-78' SISNED IV/p Ball=

DATE(N CERTlFICATE 0OIDER) P1ri pal Qual y Assurance Engiear OUR ASE CERTIFICATE OF AUTIIORIZATICO MD. 71-1747 _ UDSE THE M SYMBOL EXP!RES Ma 20, 1980 (NV)

(DATE)

CERTIFICATION Of 0131?t DESIGN INFORNATION 0N FILE AT 1resbr-Plarm, AlexAndrfia, TA..

STRESS ANALYSIS REPORT (CLASS I ONLY) ON FILE AT Dress2r Wlpant Al ewaredr4^ T.a_

DESISJI SPECIFICATIONS CERTIFIED AVI Johtn IIU_ M 1.par PE STATE V4 r ln. Rao. No. 4418 STRESS REPORT CERTIFIED ay' Y.S. Lai FE STATE T.nLouisina RE2.N3. 14105 1

SISNATURE NOT REQUIRED-LIST NAME ONLY CERTIFICATE OF SHOP INSPECTION ITHE UNOERSIGNED. HOLDINS A VALID COMNISSION ISSUED BY THE NATIONAL BOA2D DF DOILIR AND PRESSURE VESSEL INSPECTORS ANO THE ;TATE OR PROVINCE OF LOUISIANA AND EMPLOYED BY TlE HARTFCA§ STal ILA BST 1..II.

COUP1W OF IANTFOPA, CCXN., HAVE INSPECTED THE PUIP.OR VALVE.DESCRIVD IN TNIS DATh REPORT ON 19.A AND STATE THAT TO TIHE DEST OF BY INOVLEDG1 AND SELIEF.TNS X CERTIFICATE HOLDER 1IAS CONSTRUCTED TVIS PUMP, OR.VALVE, IN ACCORDANCE WITHItHE-ASME CODE FOR NUCLEAR FI1ER PLANT COMPONENTS.

BY SININ3 THIS CERTIFICATE. NEITHER THE INSPECTOR NOR HIS EMPLOYER KAXES ANY VARIIAIRYEXPAISSED OR IMPLIED, CONCERNINI THE £QUIPMENT DESCRIBED IN THIS DATA REPORT.FUTHERVORE.NEITHER. THE INSPECTOR NOR HIS EMPLOYER SHALL BE LIABLE IN ANY MAMNEA FOR ANY PERSONAL INJURY OR PROPERTY DAMASE OR A LOSS OF ANiT KIND ARISINI FO oOR Dnp; E. WIT SIS IB FICTION.

DAtE _102 I In' I4'fly SDAMEP. A&P T tw e COEMISSIONSNational Board No. 7876 I SPECTOR) .NATOL.DR.STATE PROY.AN ND.)

V . - _

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xl

1. Owner: Calvert Cliffs Nuclear Power Plant, Inc. Date: 6115/2004 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet 1of 2 (address)
2. Plant: Calvert Cliffs Nuclear Power Plant Unit: One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-056a, MWO No. 1200203364 (address) (P.O. no., job no., etc.)
3. Work Performed by: Calvert Cliffs Nuclear Power Plant Dept. Type Code Syrbol Stamp: N/A (name) Authorization No.: N/A Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class: One (address)
4. Identification of System: System Number 064 System Name: Reactor Coolant System 5.(a) Applicable Construction Code and Class: ASME B31.7 1969 Edition, Sum. 1971 Add; Class I (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition
6. Identification of Components Repaired or Replaced and Replacement Components: ASME Repaired, Code Name of Name of Manufacturers National Other Year Replaced, oi Stamped Componet Manufacturer Serial Number Board No. Identification Built Replacemen (Yes or No)

Piping System Bechtel 21/2"CC-10-1007 N/A - #11 Pressurizer Piping to Safety 1975 Repalred/Repi No Relief Valve 1-RV-200 aced Nut Mackson Inc. 409779 Heat Code: N/A Nut, Heavy Hex, 11/8 In.X 8 TPI, 2003 Replacement No AGM ASME SA-194 Gr. 7 Rod Nova Machine 38612 Heat Code: N/A Rod, Allthread, I 1/8 In.X 8 TPI, 1999 Replacement No Products Corp. MWX ASME SA-193 Gr. B7

7. Description of Work:

This plan was for the replacement of pressure retaining fastener materials to assist in the replacement of Unit-1 Pressurizer Safety Valve, 1-RV-200.

8. Tests Conducted: Hydrostatic:E Pneumatic] Nominal Operating Pressure: Inservice: E Leakage: 1 Functional: I]

Pressure: N/A psi. Test Temperature: N/A Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

.nr -

C} - - Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section XI VT-1 Visual Examination of the reDlacement threaded fasteners was performed to satisfy Section XI Pre-Service NDE Requirements.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Renalr/Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H. Ballard Signed: /n/a, g Engineering Technician Date: 6/15/2004 Owner-o'wner's De rinee, Titr Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period 39 V Y to 6,11 @e . and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

DO ddZ-0 4 - S14-ePoMr f ,,=t ,V.

EUOH,%) A4OiCfs pat-GA F Commissions: 4J13 7?S3/, /) /1 7/ AWY Tnqntnr'qs1;in hatre National Board, State, and Endorsements Date: 6 -/7 -------- 1 f-

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xi

1. Owner: Calvert Cliffs Nuclear Power Plant, Inc. Date: 6118/2004 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet I of 2 (address)
2. Plant: Calvert Cliffs Nuclear Power Plant Unit: One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2004-1-027, MWO No. 1200203390 (address) (P.O. no., job no., etc.)

Type Code Synbol Stamp: N/A

3. Work Performed by: Calvert Cliffs Nuclear Power Plant Dept. Authorization No.: N/A (name)

Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class: One (address)

4. Identification of System: System Number 064 SystemName: ReactorCoolantSystem 5.(a) Applicable Construction Code and Class: ASME B&PV Code Sect. 1I1,1965 Edition, Win.1967 Add; Class A CCases: 1335-2, 1336, 1359-1 (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition
6. Identification of Components Repaired or Replaced and Replacement Components: ASME Repaired, Code Name of Name of Manufacturers National Other Year Replaced, oi Stamped Componet Manufacturer Serial Number Board No. Identification Built Replacemen (Yes or No)

Pressure Vessel Combustion Vessel SN: 67107; 20911 Unit PI Reactor Vessel and Head 1971 Repaired/Repl Yes Engineering Head SN: 67207 aced ICI Flange ABB Combustion 95991-GX SN: 94- N/A Flange, S In., 2500 lb, Large 1994 Replacement No Engineering 0855 Tongue, Blind with 6 holes for ICI's, ASTM A-182, Gr.F321 Plug BGE CCNPP Shops 0200101511 SN: N/A Plug, Incore Detection Seal, Dwg. 2001 Replacement No 011, 012 & 013 12148-03,ASTM-A276, Ty316 SS

7. Description of Work:

This plan was for the installation of dummy stainless steel ICI plugs and a new In Core Instrumentation Flange on Unit #1 Reactor Vessel at the #4 ICI penetration.

8. Tests Conducted: Hydrostatic:E Pneumaticfl Nominal Operating Pressure: Inservice: l Leakage: b Functional: a]

Pressure: 2260 psi. Test Temperature: 660 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 1I in., (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section Xl VT-1 Visual Examination of the replacement threaded fasteners was performed to satisfy Simertinn Yl Prp-.qprvirA Ngl Rqnutiremnts A Rpreninn -YIX Svrtm I ank-n Tt Ta f Ikf

-tv ...-,\

g!ffg%&tofr41
  • Io

&r^mn,%nfn#

wlvI&t a l Iu~\.- Ac o *_*--lllu. ow>g1 was performed durinq the system conditions listed in section 8. of this report.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Repair/Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H. Ballard Signed: W Engineering Technician Date: 6/18/2004 Owner ofOwner's Designee, Ttkle Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period /-a 'if 7

-0 to 5- /0 -09 , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

DoAd-t SrZ A. 5"194 A2.R, A,4kI1Al C04-71;S 7- L-F4C Commissions: AJIB ;;  ; J X. i/&T 5e. -1 -la A4 A / 7 n9 Nai o7 Ste

/ a Ere Inspector's Sign;ture National Board, State, and Endorsemnents Date: 200 2"00-1-u

'~I--- ii FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xl

1. Owner: Calvert Cliffs Nuclear Power Plant, Inc. Date: 6/1512004 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet 1 of 2 (address)
2. Plant: Calvert Cliffs Nuclear Power Plant Unit: One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2004-1-010, MWO No. 1200203521 (address) (P.O. no., job no., etc.)

Type Code Symbol Stamp: N/A

3. Work Performed by: Calvert Cliffs Nuclear Power Plant Dept. Authorization No.: N/A (name)

Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class: Two (address)

4. Identification of System: System Number 083 System Name: - Main Steam & SG Blowdown 5.(a) Applicable Construction Code and Class: ASME B&PV Code Sect. III,1977 Edition, Win.1979 Add; Class 2 (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition
6. Identification of Components Repaired or Replaced and Replacement Components: - ASME Repaired, Code Name of Name of Manufacturers National Other Year Replaced, oi Stamped Componet Manufacturer Serial Number Board No. Identification Built Replacemen (Yes or No)

Valve Fisher Controls 8252433436 N/A #11ISteam Generator Auxiliary 1980 RepalredtRepl Yes Feed Water Pump Steam Supply aced Control Valve Plug, Primary Fisher Controls 76678-GX SN: N/A Plug, Primary, 6 In. Control 1992 Replacement Yes Intl., Inc. LB3717-1 Valve, ASME SA-479, Gr. 316L /

Stellite, BGEDRWG #1229040018, Item 67

7. Description of Work:

This plan was for the work and part needed to rebuild 1-CV-4070, #11 Steam Generator Auxiliary Feed Water Pump Steam Supply Control Valve.

8. Tests Conducted: Hydrostatic:[] Pneumatico Nominal Operating Pressure: Inservice: E Leakage: f Functional: [

Pressure: NiA psi. Test Temperature: N/A Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) information in Items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

No Section Xi Pre-Service NDE was performed in suODort of this activity.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Repalr/Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A Dso e iX e4 Charles H. Ballard Signed: 5, Engineering Technician Date: 6/15/2004 Owner orT er's rs-igne'e itle Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described inthisOwner'sReportduringtheperiod d-/a - 0M to S -t- e'l , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected w'th this inspection.

45. ,:OR-

/R af iH

= JO A;?-L'AS PEZ 7.L.-fLFYAX Commissions: AJ 3r983 , /10//7/, -'J//

Inspectores Signature National Board, State, and Endorsements Date: 6-14'* 200O4

003B-P21C18573 FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAteM 0001 NUCLEAR PARTS AND APPURTENANCES As Required by the Provisions of the ASME Code,Section III Not To Exceed One Day's Production Pg. of

1. Manufactured end certified by FISHER CONTROLS INT'L INC, KAPSHALLTOWN, IOWA 50158 InaW and 8sd&s ot NPT Certifcate 14old0f
2. Manulacturedfor Baltimore Gas & Electric Co.. Box 1535, Baltimore. Md. 21203 sname and address of ovicnlaserI
3. Locationofinstallation Calvert Cliffs Nuclear Station. Lbsby. Md. 20657

.nAn am lcddressi

4. Type 34A2071 Rev G SA-479-S31603 70.0 KSI N/A 1993

-draweng 1.1 'Matil spec. noJ tnflStr*Ngthl -CNI ear bwlt

5. ASME Coda, Section III: 1977 Winter 1979 2 N/A a.0t.Ons addends alts iclasse Code Case moI
6. Fabricated in accordance with Const. Spec. IDiv. 2 onlyl N/A Revision N/A Date N/A

'no.,

7. Remarks:

PARTS ARE FOR VALVE SIN 8252433-436

8. Nom. thickness in. l NIA Min, design thickness (in.ANA Die. ID fit & in.) - NLA.- Length overall (ft & in.I N/A
9. When applicable. Certificate Holders' Data Reports are attached for each item of this report:

Part or Appurtenance -N efc Part or Appurtenance National Serial Number 1 4O o.No II Serial Number Board Number

.m.NlOideS  ! § in Numerical Order Heat Number I i1 LB3717-1 31333-1 '26)

12) 1(27) 13! !128) ---- I
14) :429)

,,  !: m1.

.aVP

-I 161, I-131)

(73 (32)

'8) (33t

19) 1341 (10) 1351 t111  :(361 1 137) 1131 _138) t14) - _-_ - _._. 139) -

015 :_ (403 I -.___

116. _ 141) 71 142 _

11i_..). 143) _

  • 191 - 144 .

120) 345)

(21) 1461 122) 147)

.123) *148)

  • 124) :149)

'125) . (i0- -_

10. Design pressure 1000 psi. Temp. 580 F. Hydro, test pressure N-A at temp. F
  • ponatiep~e j.1
  • Supplemental informatioin the form o lists. sketches. or drawings may be used provided 311site is 8X K t 121 2Informtion in stems 2 and 3 on ths Data Reort is included on each sheet. i31 each sheet is numbered and the numboer of sheets Is recorded at the top of this form.

112/86) This form (E000403 may be obtained from the Order Oct.. ASME. 22 Low Dive. Box 2300. Fasirfield, NJ 07007.2300.

- 'I- -I FORM N-2 (back)

Mfr. Serial No.

CERTIFICATION OF DESIGN Design specifications certified by Robert F. Ash PE State Md. Rel n. 9198 Design report certified by N/A PE. State N/A Fel.no. N/A l ~whefl Ip4.aob~e)

CERTIFICATE OF SHOP COMPLIANCE We certify that the statements made in this report are correct and that this Ithese) Primary Plug conforms to the rules of construction of the ASME Code, Section Ill.

NPT Certificate of Authorization No. 1930 Expires 11-18-95 Date 7-: Name FISHER CONTROLS INT'L INC NPT Cert.ieste Holdeu Signed < a ra_Ilutihonzed eptesontatZ CERTIFICATE OF SHOP INSPECTION

  • tigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province ofI dA and employed by HARTFORD S.B.I & I CO.

of HARTFORD. CONN have inspected these items described in this Dats Repor on_ 7 " S - . and state that to the i best of my nowledge and belief, the Certificate Holder has fabricated these parts or appurtenances in accordance with the ASME Code. Section l Ill. Each part I sted has been authorized for stamping on the date shown above.

By signing this certificate. neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the equipment described In this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising fram or connected with this inspection.

Date 7-2? 3 Signed 7 i. ( 4 tAuthenzed Inetorl Commissions °;a4*

KN&OCM. 1Inal. endoreamonisl staesat Sav. ane nol!

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner: Calvert Cliffs Nuclear Power Plant, Inc. Date: 6/1712004 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet 1of 2 (address)
2. Plant: Calvert Cliffs Nuclear Power Plant Unit One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-032, MWO No. 1200203958 (address) (P.O. no.. job no., etc.)
3. Work Performed by: Calvert Cliffs Nuclear Power Plant Dept. Type Code Symbol Stamp: N/A (name) Authorization No.: N/A Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class: One (address)
4. Identification of Systemn System Number 064 System Name: Reactor Coolant System 5.(a)Applicable Construction Code and Class: ASME B&PV Code Sect. 1I1,1983 Edition, Sum. 1983 Add; Class I (b) Applicable Sect XM Ed. for Repairs/Replacement 1998 Edition
6. Identification of Components Repaired or Replaced and Replacement Components: ASME Repaired, Code Name of Name of Manufacturers National Other Year Replaced, oi Stamped Componet Manufacturer Serial Number Board No. Identification Built Replacemen (Yes or No)

RCP Seal Sulzer Blngham SN: 1C869 NB 1294 #12A Reactor Coolant Pump 1988 Repaired/Repi Yes Inc. Mechanical Seal aced Seal BGE CCNPP Shops 1200202602 SN: NB 1290 Seal, Cartridge Assembly (RCP) 2003 Replacement Yes IC870 875B-3V Complete Sulzer Blngham per FCR 87-0074

7. Description of Work:

This plan was for the replacement of the mechanical seal on #12A Reactor Coolant Pump.

8. Tests Conducted: Hydrostatic:E Pneumatics Nominal Operating Pressure: - Inservice: E Leakage: 0 Functional:E Pressure: 2260 psi. Test Temperature: 532 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 3X FORM NIS-2 (Back)

9. Remarks:

A Section Xl System Leakage Test of the affected component was oerformed during the system conditions listed in section 8. of this report.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Repalr/Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H.Ballard Signed: , , Engineering Technician _Date: 6/17/2004 Owner ororwerss ignee, T ite Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described inthisOwner'sReportduringtheperiod 6' -A' 3 to 6-/1 69y ,andstatetothebestofmy knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

OHAJ 4J*Zl Pg z-f Comnissions: A16\ 9A-3) , 1t9 11/7/, FhJ N7at io7 Bo

'a State and EndI D Inspector's Signature National Board, State, and Endorsemnents Date: _ _ _I 200 Y

T -d FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xl

1. Owner: Calvert Cliffs Nuclear Power Plant, Inc. Date: 611512004 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet I of 2 (address)
2. Plant: Calvert Cliffs Nuclear Power Plant Unit: One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-008, MWO No. 1200203966 (address) (P.O. no., job no., etc.)

Type Code Symbol Stamp: N/A

3. Work Performed by: Calvert Cliffs Nuclear Power Plant Dept. Authorization No.: N/A (name)

Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class: One (address)

4. Identification of System: System Number 064 System Name: Reactor Coolant System 5.(a) Applicable Construction Code and Class: ASME B&PV Code Sect. 111, 1968 EditIon, Win. 1968 Add; Class A, Cases N-2, N-10 (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition
6. Identification of Components Repaired or Replaced and Replacement Components: ASME Repaired, Code Name of Name of Manufacturers National Other Year Replaced, ox Stamped Componet Manufacturer Serial Number Board No. Identification Built Replacemen (Yes or No)

Valve Dresser Industrial SN: BM-07952 N/A Unit One Pressurizer Safety 1977 Repaired/Rep] Yes Valve Co. Relief Valve aced Nozzle Dresser Industries 86592-GX SN: N/A Nozzle, Maxiflow Relief Valve, 2 1987 Replacement Yes Inc. AAB60 1/2 In., Model 31739A, Dresser P/N 4231701N, ASME SA-182 Gr.

F347 Relief Valve Dresser Industries 404679 SN: BM- N/A Valve, Consolidated Closed 2002 Replacement Yes Inc. 07948 Bonnet Maxiflow Safety; 2-1/2 In.

Model 31739A, only for RV 201 location.

Disc Dresser IndustrIes 95597-GX SN: N/A DIsc, Maxinlow ReliefValve,2 1/2 1995 Replacement Yes Inc. ACM73 In., Model 31739A, Dresser P/N 1840404N, ASME SB-637 Gr. 688

7. Description of Work:

This plan was for the replacement of Unit-1 Pressurizer Safety Valve, 1-RV-201.

8. Tests Conducted: Hydrostatic:[ PneumaticO Nominal Operating Pressure: Inservice: O Leakage:R Functional: E Pressure: 2260 psi. Test Temperature: 660 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section Xi VT-1 Visual Examination of the replacement threaded fasteners was performed to satisfy Q.Crfinn YX Prga:hfrui' tJvtIflu I P I I -I%-

fl Pgn.,;rnmmnta NIF .. -v4- I -av II,-J. A Section Xi System Leakage Test of the affected CO Donent was performed during the system conditions listed in section 8. of this report.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Repair/Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H.Ballard Signed: Z" "/ n'1. /

Owner or Owner's Designee, TieT Engineering Technician Date: 6/15/2004 Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period //-f 2)- 0 3 to 6 -/0 - 0 4 , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

iDOA)41-0, A . j.nM fitZ ,Yi2i.

ZYOH- A10f-2-IS pL'YZ-ff Commissions: AJ157953 1AfO/17/, 4Ad//

NJ ationa Boad a0 / a nd S Inspector's Signature National Board, State, and Endorsements Date: 7-/6 200 1

Alexandria. Louisiana USA FORM N-2 OR NPr CERTIFICATE HOLDERS' DATA REPORT FOR IDOENMCAL NUCLEAR PARTS AND APPURIENANCES-As Required by the Provisions of the ASME Code,Section III, Div. 1 Not to Exceed One Day's Production Page l of 1 Dresser Industries, Inc., Dresser Valve & Controls Div. Industrial Valve Operations

1. Manufactured and certified by Intersection Hwy. 167 & 3225 North, Alexandria, LA 71309-1430 (Name and Address of Certificate Holder) .
2. Manufactured for Baltimore Gas & Electric P. 0. Box 1635 Baltimore, MD 21203-1535 (Name and A"dres of Purchaser)
3. Location of Installation Baltimore Gas & Electric 1650 Calverts Cliffs Parkway Lusby, MD 20657 (Name and Address)
4. Type OS417 SB637 Inconel X750 NIA NIA 1995 (Drawing NoJ (Mat'l. Spec. NoJ frensile Strength) (CRNM (Year Built)
5. ASME Code, Section III: 1968 Winter 1968 A Article 9 NIA (Edition) (Addenda) (Class) ICode Case No.)
6. Fabricated in accordance with Const. Spec. (Div. 2 only) N/A Revislor I N/A Date N/A
7. Remarks: N/A No.)
8. Nom. thickness (in.) NIA Min. design thickness lin.)_NLfADia. ID (ft.&in.)NIA_.Length overall (ft.&in.)l N/A
9. When anolicable. Certificate Holders' data renorts are attached for each item of this report. t Part or Appurtenance National Board No. Par or Appurtenance National Board No.

Serial Number In Numerical Order Sorial Number In Numerical Order tll Af-7M 71 I) ACM 79 19A7 19pi t12 A MtP72 _

141 ALM 74 I'M th90 _ ___ _ _ _ _ _ _ _ _ _

{ 12fl ._ __ _ _ __ ___ _ __ _ _

IA)1AM 7R_

till

  1. 191,0 IR) fill 119) 127) f4Q1 .

12411

'IA)

(IMs fI2~

11 7 II .

__} _ (*4 4 49 1 1_ _ __ _ __ _ _ _ _ __ _ __ _ __ _

14S;) __ _ _ _ _ _ _ _ _ _ _ _

Mdi} I4415 _ _ _ _ _ _ _ _ _ _ _ __ _ _

I47 l'~

1O.Deslgn Pressure N/A psi Temp. N/A 'F Hydro test pressure 4500 at temp. 'F

  • Supplemental information in form of lists, sketches or drawings may be used provided, 41) size Is8X xI1, (2)information in items 2 & 3 on this data report is Included on each sheet, (3) sheet Is numbered and number of sheets is recorded at top of this form, and (4) each additional sheet shall be signed by the Certificate Holder and the ANI.

_ r---_

CERTIFICATE OF DESIGN Design specifications certified by N/A P.E. NIA Reg. no. NIA (when applicable)

Design report' certified by NIA P.E. N/A Reg. no. N/ilA CERTIFICATE OF SHOP COMPLIANCE We certify that the statements made in this report are correct and that these disc conform to the rules of construction of the ASME Code, Section Ill.

NPT Certificate of Authorization No. N-2434 . Expires Mau 20. 1995 Date 4/2 Lqs Name See Line 1 (NPT Certificat. Holder)

Signed (authorized repros CERTIFICATE OF SHOP COMPLIANCE 1.the undersigned, holding a valid commission by the National Board of Boiler and Pressure Vessel Inspector and the state or province of Louisiana and employed by The Hartford Steam Boiler lnpect n_ Insurance Co.,

of Hartford, CT, have Inspected these items described in this data report on ________S . and state that to the best of my knowledge and believe, the Certificate Holder has fabricated these parts or appurtenances In accordance with the ASME Code, Section Ill. Each part listed has been authorized for stamping on the date shown above.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or Implied concerning the equipment described In this data report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Date _ Signed ,M I Commissions _ _ _ _ _ _

(Athoidzed Inspectorl INalt. 8d. Onol. endorsements) state or prov. andno.)

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xl

1. Owner: Calvert Cliffs Nuclear Power Plant, Inc. Date: 611512004 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet I of 2 (address)
2. Plant: Calvert Cliffs Nuclear Power Plant Unit: One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-008a, MWO No. 1200203966 (address) (P.O. no., job no., etc.)
3. Work Performed by: Calvert Cliffs Nuclear Power Plant Dept. Type Code Symbol Stamp: N/A (name) Authorization No.: N/A Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class: One (address)
4. Identification of System: System Number 064 SystemName: Reactor Coolant System 5.(a)ApplicableConstructionCodeandClass: ASME B31.7 1969 Edition, Sum. 1971 Add; Class I (b) Applicable Sect Xl Ed. for Repairs/Replacement 1998 Edition '
6. Identification of Components Repaired or Replaced and Replacement Components: ASME Repaired, Code Name of Name of Manufacturers National Other Year Replaced, oi Stamped Componet Manufacturer Serial Number Board No. Identification Built Replacemen (Yes or No)

Piping System Bechtel 2 1/2"CC-10-1008 N/A #11 Pressurizer Piping to Safety 1975 Repalred/Repl No Relief Valve 1-RV-201 aced Nut Mackson Inc. 409779 Heat Code: NIA Nut, Heavy Hex, 11/8 In. X 8 TPI, 2003 Replacement No AGM ASME SA-194 Cr. 7 Rod Nova Machine 38612 Heat Code: N/A Rod, Allthread, 1 1/8 In. X 8 TPI, 1999 Replacement No Products Corp. MWX ASME SA-193 Gr. B7

7. Description of Work:

This plan was for the replacement of pressure retaining fastener materials to assist in the replacement of Unit-I Pressurizer Safety Valve, 1-RV-201.

8. Tests Conducted: Hydrostatic:E PneumaticO Nominal Operating Pressure: Inservice: E Leakage: fl Functional: fl Pressure: NIA psi. Test Temperature: N/A Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x I I in., (2) information in Items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section XI VT-I Visual Examination of the replacement threaded fasteners was performed to satisfy Section Xl Pre-Service NDE Requirements.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Renalr/Relacerment conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A A~<(2 5 ~1I.&/LjCharles H.Ballard Signed: , Engineering Technician Date: 6/15/2004 Owner or Owner's Designee, Tite Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described inthis Owner's Report during the period / .2- O' to 56-/°09 , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

()Q~s A XSHA4-P//$ F . A/.

HU t o Commissions: V 8q JI3 /5 0 /7t A e//

Al /S / X779' A1,0 /X/

National Board, State, and Endorsements Date: 200

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section XI

1. Owner: Calvert Cliffs Nuclear Power Plant, Inc. Date: 6/1512004 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet 1of 2 (address)
2. Plant: Calvert Cliffs Nuclear Power Plant .

Unit: One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-057, MWO No. 1200204093 (address) (P.O. no., job no., etc.)

Type Code Symbol Stamp: N/A

3. Work Performed by: Calvert Cliffs Nuclear Power Plant Dept. Authorization No.: N/A (name)

Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class: One (address)

4. Identification of System. System Number 064 SystemName: Reactor Coolant System 5.(a) Applicable Construction Code and Class: ASME B&PV Code Sect. III, 1968 Edition, Win. 1968 Add; Class A, CCases 1581, N-2, N-10 (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition
6. Identification of Components Repaired or Replaced and Replacement Components: ASME Repaired, Code Name of Name of Manufacturers National Other Year Replaced, ox Stamped Componet Manufacturer Serial Number Board No. Identification Built Replacemen (Yes or No)

Valve Dresser Industries BM-07951 N/A Unit H1 Pressurizer Electromatic 1996 Repaired/Repi No Power Operated Safety Valve aced Electromatic Dresser Industries 402603 SN: BS- NIA Valve, Pressurizer ERV, 2 1/2 In. 2001 Replacement No Relief Valve Inc. 07325 2500 lb., Consolidated Electromatic, P/N: 31533VX-30 XFF1-NC2005

7. Description of Work:

This plan was for the replacement of Unit-1 Pressurizer Power Operated Relief Valve 1-ERV-404.

8. Tests Conducted: Hydrostatic:] Pneumatic{] Nominal Operating Pressure: Inservice: 17 Leakage: i Functional: E]

Pressure: 2260 psi. Test Temperature: 660 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section Xl System Leakage Test of the affected component was performed durina the system conditions listed in section 8. of this report.

- Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Repair/Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H.Ballard Signed: / Engineering Technician Date: 6/15/2004 Owner or Owner's Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period 8- a 1-3 to 6 -//-a . and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection DOt4a- A .31,f li4 v ql.o AceJ AiO2rZ-Ifi PbLYZ 7,S-7-C-A4q-- Commissions: 4AC 9 0'3 / , AfD//7/ 4.A///

,J ,Nl775 l Ai oaSt S Imnecor'sSi~ntureNational Board, State, and Endorsements Date: A- 16 --

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xl

1. Owner: Calvert Cliffs Nuclear Power Plant, Inc. Date: 6/1512004 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet 1 of 2 (address)
2. Plant: Calvert Cliffs Nuclear Power Plant Unit: One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-057a, MWO No. 1200204093 (address) (P.O. no.,job no., etc.)

Type Code Symbol Stamp: N/A

3. Work Performed by: Calvert Cliffs Nuclear Power Plant Dept. Authorization No.: N/A (name)

Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class: One (address)

4. Identification of System: SystemNumber 064 SystemName: - Reactor Coolant System 5.(a)ApplicableConstructionCodeandClass: ASME B31.7 1969 Edition, Sum. 1971 Add; Class I (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition
6. Identification of Components Repaired or Replaced and Replacement Components: ASME Repaired, Code Name of Name of Manufacturers National Other Year Replaced, oi Stamped Componet Manufacturer Serial Number Board No. Identification Built Replacemen (Yes or No)

Piping System Bechtel 2 1I2"CC-10-1004 N/A #11 Pressurizer Piping to 1-ERV- 1975 Repaired/Repi No 404 aced Nut Nova Machine 38612 Heat Code: N/A Nut, Heavy Hex, 1 1/ In. X 8 TPI, 1999 Replacement No Products Corp. MVJ ASME SA-194 Gr. 7 Rod Nova Machine 38612 Heat Code: N/A Rod, Allthread, 1 1/8 In. X 8 TPI, 1999 Replacement No Products Corp. MWX ASME SA-193 Gr. B7

7. Description of Work:

This plan was for the replacement of fastener materials to support the replacement of the Unit-1 Pressurizer Power Operated Relief Valve 1-ERV-404.

8. Tests Conducted: Hydrostatic:E] PneumaticO Nominal Operating Pressure: Inservice: E Leakage: [ Functional: E Pressure: N/A psi. Test Temperature: N/A Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2of 2 FORM NIS-2 (Back)

9. Remarks:

A Section XI VT-1 Visual Examination of the replacement threaded fasteners was Performed to satisfy Section Xl Pre-Service NDE Requirements.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Renalr/Reolacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H.Ballard Signed: Engineering Technician Date: 6/15/2004 Owner or Owneres Designee, Title -

Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period 9- aS - __ to 6 //-OY , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

4M-4Z/S Commissions: Ai13 913/ , A1f) 1274, .P`/

-= tn nIS A77oa A n Edrmn Ins~ctoss sznaureNational Board, State, and Endorsements Date: (a -0/

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xi

1. Owner: Calvert Cliffs Nuclear Power Plant, Inc. Date: 6118/2004 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet I of 2 (address)
2. Plant: Calvert Cliffs Nuclear Power Plant Unit: One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-058, MWO No. 1200204377 (address) (P.O. no., job no., etc.)

,pt. Type Code Symbol Stamp: N/A

3. Work Performed by: Calvert Cliffs Nuclear Power Plant De (name)

Authorization No.: N/A Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class: One (addirss)

4. Identification of System: System Number 064 System Name: Reactor Coolant System 5.(a) Applicable Construction Code and Class: ASME B&PV Code Sect. 1I1,1968 Edition, Win.1968 Add; Class A,

-CCases 1581, N-2, N-10 (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 EditIon

6. Identification of Components Repaired or Replaced and Replacement Components: ASME Repaired, Code Name of Name of Manufacturers National Other Year Replaced, oi Stamped Componet Manufacturer Serial Number - Board No. Identification Built Replacemen (Yes or No)

Valve Dresser Industries BM.07950 N/A Unit #1 Pressurizer Electromatic 1975 Repalred/Repl No Power Operated Safety Valve aced Electromatic Wyle Laboratories 412522 SN: BY- N/A Valve, Pressurizer ERV, 21/2 In. 2004 Replacement No Relief Valve 77325 2500 lb., Consolidated Electromatic, PIN: 31533VX-30 XFFI-NC200S

7. Description of Work:

This plan was for the replacement of Unit-1 Pressurizer Power Operated Relief Valve 1-ERV-402.

8. Tests Conducted: Hydrostatic:n PneumaticO Nominal Operating Pressure: Inservice: n Leakage: i Functional: E Pressure: 2260 psi. Test Temperature: 660 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) information in Items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section Xi VT-1 Visual Examination of the replacement threaded fasteners was performed to satisfy Section Xi Pre-Service NDE Requirements. A Section Xi System Leakage Test of the affected component was performed during the system conditions listed in section 8. of this report.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Renair/Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H.Ballard Signed: G Engineering Technician Date: 6/18/2004 Owner or owneis Designee, Trile Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period ? - a / - 0 3 to 6 /-C*O9 .and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section XM.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

DWJ4-- '1 .SH1 Sad" r F0tZ H12 MA10VJ^- 6Co7S Commissions: / 13 9/i (of!) //63 6e Siatur Nional Bard, Ste a m1 aInspector's Signature National Board, State, and Endorsements Date: ( - -L- -- 2O- -

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl.

1. Owner: Calvert Cliffs Nuclear Power Plant, Inc. Date: 611812004 ':

(name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet I of 2 (address)

2. Plant: Calvert Cliffs Nuclear Power Plant Unit: One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-058a, MWO No. 1200204377 (address) (P.O. no.. job no., etc.)

Type Code Symbol Stamp: N/A

3. Work Performed by: Calvert Cliffs Nuclear Power Plant Dept.

(name)

Authorization No.: N/A Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class: One (address)

4. Identification of System: SystemNumber 064 SystemName: Reactor Coolant System 5.(a) Applicable ConstructionCode and Class: ASME B31.7 1969 Edition, Sum. 1971 Add; Class I (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition
6. Identification of Components Repaired or Replaced and Replacement Components: ASME Repaired, Code Name of Name of Manufacturers National Other Year Replaced, oi Stamped Conponet Manufacturer Serial Number Board No. Identification Built Replacemen (Yes or No)

Piping System Bechtel 2 1/2"CC-10-1003 N/A #11 Pressurizer Piping to 1-ERV- 1975 Repaired/Repl No 402 aced Nut Nova Machine 38612 Heat Code: N/A Nut, Heavy Hex, 1 1/8 In. X 8 TPI, 1999 Replacement No Products Corp. MVJ ASME SA-194 Gr. 7 Rod Nova Machine 38612 Heat Code: N/A Rod, AlIthread, 1 1/S In. X 8 TPI, 1999 Replacement No Products Corp. MWX ASME SA-193 Gr. B7

7. Description of Work.

This plan was for the replacement of fastener materials to support the replacement of the Unit-1 Pressurizer Power Operated Relief Valve 1-ERV-402.

8. Tests Conducted: Hydrostatic:E Pneumaticj Nominal Operating Pressure: Inservice: E Leakage: El Functional: [

Pressure: N/A psi. Test Temperature: N/A Deg. F NOTE Siujppemeiinl sheetsm nform of lists, sketches, or drawings may be used, provided[(l1) size is 8-1/2 in. x 11 in., (2) information in Items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section Xl VT-1 Visual Examination of the replacement threaded fasteners was performed to satisfy Section Xl Pre-Service NDE Requirements.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Repalr/Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H.Ballard Signed: Engineering Technician Date: 6/18/2004 Owner or nwrer' es~lignee,ritle Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period Y/ -2 kO091 to 6 -/ ov / and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

DoMJ/f-L- A - S q. 4'//V 7 F , C IV -ZIVIAJC6 -S Pht - 82L Commissions: A113 7 , /. I/S A )/465

- Insnector's Signature National Board, State, and Endorsements Date: - =L- 200O4r

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xi

1. Owner: Calvert Cliffs Nuclear Power Plant, Inc. Date: 11/17/2003 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet I of 2 (address)
2. Plant: Calvert Cliffs Nuclear Power Plant Unit: One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2002-1-052, MWO No. 1200204580 (address) (P.O. no., job no., etc.)
3. Work Performed by Calvert Cliffs Nuclear Power Plant Dept. Type Code Symbol Stamp: N/A (name) Authorization No.: N/A Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class: One (address)
4. Identification of Systemn System Number 064 SystemName: Reactor Coolant System 5.(a)Applicable ConstructionCode and Class: ASME B&PV Code Sect. Ill, 1968 Edition, Winter 1968 Add; Class A, CCases N-2, N-10.

(b) Applicable Sect XI Ed. for Repairs/Replacement 1998 EditIon

6. Identification of Components Repaired or Replaced and Replacement Components: ASME Repaired, Code Name of Name of Manufacturers National Other Year Replaced, oz Stamped Componet Manufacturer Serial Number Board No. Identification Built Replacemen (Yes or No)

Valve Dresser Industrial SN: BN-04373 N/A Unit One Pressurizer Safety 1977 Repalred/Repi Yes Valve Co. Relief Valve aced Nozzle Dresser Industries 15988-GX SN: ACS N/A Nozzle, Maxflfow Relief Valve, 2 1996 Replacement Yes Inc. 96 1/2 In, Model 31739A, Dresser F/N 423170 IN, ASME SA-182 Gr.

F347 Relief Valve Dresser Industries 404679 SN: BM- N/A Valve, Consolidated Closed 2002 Replacement - Yes Inc. 07953 Bonnet Maxiflow Safety; 2-112 In.

Model 31739A, only for RV 200 location.

Disc Dresser Industries 95597-GX SN: ACM N/A DIsc, Maxinfow Relief Valve, 2 1/2 1995 Replacement Yes Inc. 76 In, Model 31739A, Dresser P/N 1840404N, ASME SB-637 Gr. 688

7. Description of Work:

This plan was for the replacement of Unit-I Pressurizer Safety Valve, 1-RV-200.

8. Tests Conducted: Hydrostatic:n Pneumatico Nominal Operating Pressure: Inservicc E Leakage:E. Functional:[]

Pressure: 2250 psi. Test Temperature: 594 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section Xl VT-1 Visual Examination of the replacement threaded fasteners was performed to satisfy Section Xl Pre-Service NDE Requirements. A Section Xl System Leakaae Test of the affected component was Performed duino the system conditions listed in section 8. of this report.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Renalr/Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: NIA Expiration Date: N/A iD // Charles H. Ballard Signed: A, e nEngineering Technician Date: 11/17/2003 Owner or Owner's Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period to , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XM.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

7 Commissions: coa'x 4bg-:7 -'4)I f7DI Z / Inspector's Signature National Board, State, and Endorsements Date: / .g 20 -o

inutra ValvesI Alexandria, Louisiana USA FORM N-2 OR NPT CERliFICATE HOLDERS' DATA' REPORT FOR IDEBIiCAL NUCLEAR PARTS AND APPUIRTENANCESX As Required by the Provisions of the ASME Code,Section III, DIv. 1 Not to Exceed One Day's Production Page 1 of 1 Dresser Industries, Inc., Dresser Valve & Controls Div. Industrial Valve Operations

1. Manufactured and certified by Intersection Hwv. 167 & 3225 Nbrth. Alexandria. LA 71309-1430 IName and Address of Certificate Holder)
2. Manufactured for Baltimore Gas & Electric P. 0. Box 1535 Baltimore, MD 21203-1E35 (Name and Address of Purchaser)
3. Location of Installation Baltimore Gas & Electric 1650 Caiverts Cliffs Parkway lusby, MD 206574702 (Name end Addreasl
4. Type OS417 - SA182 Gr. F347 76 KSI N/A 1996 (Drawing No.) (Mat'l. Spec. No.1 (Tensile Strength) (CRN) (Year Built)
5. ASME Code,Section III Division 1:1968 Wrnter 1968 Article 9 (Cl. 11 NIA (Edition) (Addenda) (Class) Code Case Noj
6. Fabricated In accordance with Const. Spec. (Div. 2 only) N/A Revision iN/A Date NiA

-l--J,_.ttSA(No.) rI/P.

/. 11emarKs:

8. Norn. thickness tin.) NIA MiUn. design thickness finj) N/A Dia. ID (ft.&in.L!N/ALength overall (ft.&In.)liNA S. When applicable, Certificate Holders' data reports are attached for each item of this report.

Part or Appurtenance National Board No. Part or Appurtenance National Bloard No.

Serial Number In Numerical Order serial Number In Numerical Order 12 A) 171 5271 12R)

(1 71 _ _ _ _ _ _ _ _ _ _ _ _ _ _

14 M )_ _ _ _ _ _ _ _ _ _ _ _

4121)_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

(4 122 _ _ _ _ _ _ _ _ _ _ _ _ _

1191I (I A f117 11 71 _ _ _ _ _ _ _ _ _ _ _ _ _ _

MIt 14 0 ) _ _ _ _ _ _ _ _ _ _ _ _ _ _

fo lr)_ _ _ _ _ _ _ _ _ _ _ _ _ _

10.Design Pressure N/A psi Temp. N/A *FHydro test pressure 4500 PSIG at temp. 'F

'Supplemental Information Inform of lists, sketches or drawings may be used provided, 1I size is 8 1Kx 11, (2) Information Initems 2 & 3 on this data report Is Included on each sheet, (3) sheet Is numbered and number of sheets is recorded at top of this form, and (4) each additional sheet shall be signed by the Certificate Holder and the ANIL

CERTIFICATE OF DESIGN Design specifications certified by N/A P.E. NIA Rag. no. N/A (when applicablo)

Design reports certified by N!/A P.E. N/A Reg. no. Wj A CERTIFICATE. OF COMPLIANCE We certify that the statements made In this report are correct and that this (these) Nozzles conform to the rules of construction of the ASME Code, Section il Division 1.

NPT Certificate of Authorization No. N-2434 Expires May 20, 1998 Date l/ /9? Name See Line 1 Signed /  ?

(NPT Certificata Holder) (authodzad representalva)

CERTIFICATE OF INSPECTION l, the undersigned, holding a valid commission by the National Board of Boiler and Pressure Vessel Inspector and the state or province of Louisiana and employed by The Hartford Steam Boiler ingspctlon & Insurance Co.,

of Hartford, CT, have inspected these Items described In this data report on . and

  • /Kf state that to the best of my knowledge and believe, the Certificate Holder has fabricated these parts or appurtenances In accordance with the ASME Code, Section liI Division 1. Each part listed has been authorized for stamping on the date shown above.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or Impfled concerning the equipment described In this data report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal injury or property damage or loss of any kind arising from or connected with this Inspection.

Date Signed Commissions __ _ _ _ _ _

(Authorized rispector) MNat'l. Bd. (in. endorsement) astate or prov. and no.1

.A, r a Aeadria LuwaI A Alexandria, Laulstana USA FORM N-2 OR NPT CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES" As Required by the Provisions of the ASME Code,Section III, Div. 1 Not to Exceed One Day's Production Page I of I Dresser Industries, Inc., Dresser Valve & Controls Div. Industrial Valve Operations

1. Manufactured and certified by Intersection Hwy. 167 & 3225 North, Alexandria. LA 71309-1430 (Name end Address of Certificate Holder)
2. Manufactured for Baltimore Gas & Electric P. 0. Box 1635 Baltimore, MD 21203-1535 (Name and Address of Purchaser)
3. Location of Installation Baltimore Gas & Electric 1650 Calverts Cliffs Parkway Lusby, MD 20657 (Name and Address)
4. Type OS417 S5637 Inconel X750 NtA NJA 1995 (Drawing No.) IMat1. Spec. No.) (Tensile Strength) (CRN) (Yeer Bunt)
5. ASME Code, Section ill: 1968 Winter 1968 A Article 9 NJA lEdition) (Addenda) (Class) ICodo Case No.)
6. Fabricated In accordance with Const. Spec. (Div. 2 only) N/A Revision NIA Date N/A

- Pa- -.a(NoJ)

7. remarnas: _NM
8. Nom. thickness tin.) NIA Min. design thickness (in.) N/A Dla. ID (ft.&in.). NIALength overall (ft.&in.) NlA
9. When applicable, Certificate Holders' data reports are attached for each Item of this report.

Part or Appurtenance National Board No. Part or Appurtenance National Board No.

Serial Number In Numerical Order Serial Number In Numerical Order III A4IM 71 _ Mul MI} ArM7s 141 AthM 74 cm AeM 75 .

m7, tam

'in} , ._ _ _ _ _ _ _ _ _ _ _ _ _

t461 _ ____ __ _____. ___

{141 1341 (IRM

'in' _ _____ _ _ _ _ _ _ _

El7 --- _ _ _ _____ _ _ _ _ _

(t9m 1141_ _ _ _ _ __ _ _ _ _ _

1491 W41

~ _ '_________*______I__

1441 1468

.. 7 _ .. _.__

M5}

!'47


--I Ev41 E,%l t4rm

.. ;U... __.._..___,

10.Design Pressure N/A psi Temp. N/A *F Hydro test pressure 4500 at temp. 'F

'Supplemental Information in form of lists, sketches or drawings may be used provided, (1) size is 8Y x 11, (2) information InItems 2 & 3 on this data report Is Included on each sheet, (3) sheet Is numbered and number of sheets Is recorded at top of this form, and (4) each additional sheet shall be signed by the Certificate Holder and the ANI.

I % --- .

CERTIFICATE OF DESIGN Design specifications certified by N/A P.E. NIA Reg. no. NLA (when appUcabla)

Design report' certified by NIA P.E. N/A Rag. no. N/A CERTIFICATE OF SHOP COMPLIANCE We certify that the statements made in this report are correct and that these disc conform to the rules of construction of the ASME Code, Section IlIl.

NPT Certificate of Authorization No. N-2434 Expires May 20. 1995 Date ,/27LiL Name See line 1 Signed

'(NT Certificate Holdars (authorized rop.en CERTIFiCATE OF SHOP COMPLIANCE I, the undersigned, holding a valid commission by the National Board of BoIler and Pressure Vessel inspector and the state or province of Louisiana and employed by The Hartford Steam Boiler InoectonA Insurance Co.,

of Hartford, CT, have Inspected these Items described In this data report on //'o /IS *. and state that to the best of my knowledge and believe, the Certificate Holder has fabticated these parts or appurtenances in accordance with the ASME Code, Section lil. Each part listed has been authorized for stamping on the date shown above.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or Implied concerning the equipment described In this data report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Date Signed d ,I? Commissions ro.

/ AuthoIzed In-speotori (Nat'!. Bd. ((nol. endors amants) state or prov. and no.)

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section XI

1. Owner: Calvert Cliffs Nuclear Power Plant, Inc. Date: 11/17/2003 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet I of 2 (address) -
2. Plant: Calvert Cliffs Nuclear Power Plant Unit: One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2002-1-062, MWO No. 1200204580 (address) (P.O. no., job no., etc.)
3. Work Performed by: Calvert Cliffs Nuclear Power Plant Dept. Type Code Symbol Stamp: N/A (name) Authorization No.: N/A Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class: One (address)
4. Identification of System: System Number 064 System Name: Reactor Coolant System 5.(a) Applicable Construction Code and Class: ASME B31.7 1969 Edition, Summer 1971 Add; Class One (b)Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition
6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired, Code Name of Name of Manufacturers National Other Year Replaced, oi Stamped Componet Manufacturer Serial Number Board No. Identification Built Replacemen (Yes or No)

Piping System Bechtel 2 1/2"CC-10-1007 N/A Pressurizer Piping to Safety 1975 Repaired/Rept No Relief Valve 1-RV-200 aced Nut Cardinal Industrial S7533-GX N/A Nut, Heavy Hex, I 1/8 In. X I TPI, 1992 Replacement No Products Inc. ASME SA-194 Gr. 7 Rod Allied Nut & Bolt 18438 N/A Rod, Allthread, I 1/8 In. X 8 TPI, 1998 Replacement No Co. Inc. ASME SA-193 Gr. B7

7. Description of Work:

This plan was for the replacement of pressure retaining fastener materials on 1-RV-200 on the Inlet flange to the piping system 1#CCIO-1007.

8. Tests Conducted: Hydrostatic:E PneumaticO Nominal Operating Pressure: rIservice:E Leakage:f Functional:'El Pressure: N/A psi. Test Temperature: N/A Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section Xl VT-1 Visual Examination of the replacement threaded fasteners was performed to satisfy Section Xl Pre-Service NDE Requirements.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this RevalrlReplacement conforms to the rules of the ASME Code,Section XI.

Type Code Syrnbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: NIA

/1e I/Charles H.Ballard Signed: _ EngineeringTechnician Date: 11/17/2003 Owner or ees Designee, Title Certificate of Inservice Inspection 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period to , and state to the best of my knowledge and belief; the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section X1.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

, Commissions: A~ ZY/3/ V,7#4 - A4 /Z7(

/ Insnectoes Sigmature National Board, State, and Endorsements Date: /-- /200_ 3

FORM NIS-2 OWNER'S REPORT FOR REPAIR I REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section XI

1. Owner Calvert Cliffs Nuclear Power Plant, Inc. Date: 01124/2003

, (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet I of a.

(addmss)

2. Plant: Calvert Cliffs Nuclear Power Plant Unit: One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2002-1.060, MWO No. 1200204888 (address) (P.O. no., job no., etc.)

Cliffs Nuclear Power Plant Dept.

Calvert (nWokamre) 3 WorkPefomedby:y.Authorization Type Code Symbol NIA N/A No.: Stamp:

Exp Date: A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class: One (address)

4. Identification of System: System Number 064 SystemName: Reactor Coolant System 5.(a) Applicable Construction Code and Class: ASME B31.7 1969 Edition, Summer 1971 Add; Class One (b) Applicable Sect M Ed. for Repairs/Replacement 1998 Edition
6. Identification of Components Repaired or Replaced and Replacement Components: ASME Repaired, Code Name of Name of Manufacturers National Other Year Replaced, ol Stanmed Componet Manufacturer Serial Number Board No. Identification Built Replacemere (YMs or No)

Tubing System Bechtel I NIA NIA #11 Pressurizer Instrumentation 1970 RepalrWRepl No aced Tubing Consolidated 20439 Ht. 0442042 N/A Tubing, 1m2 In. X .065 Wall, 1998 .Replacement No Power Supply ASME BA213, Tp. 316 .7 Tubing Nut bid Atlantic 18402-GX Beat N/A Nut, Tabe, 1/2 In. Parker 1997 Replacement No Instrumentatlon Inc Code: TIH Hanuifln, P/N 8BZ4;S,  :

ASTMIASME A/SA182 or A/SA479, Tp. 316 Tubing Ferrule Mid Atlantic 18402-OX Beat N/A Ferrule, Tube, 1m2 In. Parker 1997 Replacement No Instrumentation Inc Code: CEKU -- Hanailln, PIN 8TZ-SS, ASTMJASME A/SA182 or A/SA479, Tp. 316 Tubing Union Parker Hannifin 77567-GX Heat NIA Union, Tube, 3/4 In. X In2 1992 Rep latc emen t No Corp Code: CBTD "n4arkerHannlfin, PIN 12TZ-SS,ASTMWASME A/SAIU2 or AISA479, Tp. 316

7. Description of Work: I This plan was for the work and parts needed to replace tubing and fittings upstream of 1-HVRC-1180, a drain valve for instrument I-LT-1 1OX.
8. Tests Conducted: Hydrostatic:fl PneumaticQ Nominal Operating Pressure: Inservice:C Leakagc: C Functional: Q Pressure: N/A psi. Test Temperature: N/A Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-ll2 in. x I I in., (2) information in Items 1through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheetaof g.

FORM NIS-2 (Back)

9. Remarks:

No Section Xl Pre-Serfice NDE was performed in support of this activity.

Applicable Manufactuer's Data Reports to be Attached Certificate of Complance _______cfn__

We certifyrthat the statements made in this report are correct and thatthis Roileaemrtc~onronnto the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A CertificateofAuthorizationNo.: N/A ExpirationDate: N/A

°/ (70 o4D / Charles IL Ballard Signed: Engineering Technician Date: 01/24/2003 OwnerorOwneesDesigneeitle Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components described inthis Owners Report during the period //- /O 2 to 2-2/- O3 . and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report Furtiermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or pmperty damage of a loss of any kind arising from or connected vt~ipc Commissions: A14 7/7 Z- 9P4- ,x/5 k l wr$Signature Nadonal Board, State, and Endorsements Date: Z/- 200 &L

-- - -1 FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xi

1. Owner: Calvert Cliffs Nuclear Power Plant, Inc. Date: 6/1512004 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet I of 2 (address)
2. Plant: Calvert Cliffs Nuclear Power Plant Unit: One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-022a, MWO No. 1200205233 (address) (P.O. no., job no., etc.)
3. Work Performed by: Calvert Cliffs Nuclear Power Plant Dept. Type Code Symbol Stamp: N/A (name) Authorization No.: N/A Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class: Two (address)
4. Identification of System: System Number 041 System Name: Chemical Volume Control 5.(a) Applicable ConstructionCode and Class: ASME Draft Code for Pumps & Valves,1968 Editlon, March 1970 Add; Class-2 (b) Applicable Sect Xl Ed. for Repairs/Replacement 1998 Edition
6. Identification of Components Repaired or Replaced and Replacement Conponents: ASME Repaired, Code Name of Name of Manufacturers National Other Year Replaced, o0 Stamped Componet Manufacturer Serial Number Board No. - Identification Built Replacemen (Yes or No)

Valve Velan Engineering I-CKVCVC-165 N/A #llCbargIng Pump Discharge 1975 Repalred/Repl Yes Co. Check Valve aced Check Valve Enertech Inc. 408934 SN: 11273 N/A Valve, Nozzle Check, 2 In., 1500 2002 Replacement Yes lb., Large Groove connections, Enertech, Tp. KRV (Mark #

212M3N)

7. Description of Work:

Thus plan was for the replacement of 1-CKVCVC-165, #1 ICharging Pump Discharge Check Valve.

8. Tests Conducted: Hydrostatic:] Pneumatic: Nominal Operating Pressure: Inservice: O Leakage: F Functional:

Pressure: 2400 psi. Test Temperature: 115 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x I I in., (2) information in Items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section Xi System Leakage Test of the affected component was performed durina the system conditions listed in section 8. of this report.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Repalr/Reolacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H. Ballard Signed: Engineering Technician Date: 6/15/2004 Owner or Owner's Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period 7- ~aY -03 to G -mO Y , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

,TVJ A)1Z4ZIS PEEL 7-F*FS Commissions: /V 15 I . A) II/A7/ A. //

-Anr4 NIoal Board, /w //Srse

.TIn~ectoi't 1.ionature National Board, State, and Endorsements Date: 44-,IG60

FORM NPV-I CERTIFICATE fOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES*

As Required by the Provisions of the ASME Code.Section III, Division I

1. Manufactured and certified by Enertech, A Div. of CurUss-Wright Flow Cbntrol Corp., 2950 Blirh St., Brea, CA 92821 (name and address of N Certificate Holder)
2. Manufactured for Calvert Cliffs Nuclear Power Plant, PO Box 17323, Baltimore, MD 21297-1323 (name and address of Purchaser)
3. Location ot instalation Calvert Cliffs nuclear Power Plant; 1650 Calvert Clffs Parkway,-Lusby, MD 20657 (n~ame and address)
4. Model No., Series No., or Type KRV Drawing MD20990 Rev A CaRN None
6. ASME Code, Section rtl Division 1: 1995 ba dt 1 None (edition) laddenda data) (class) lCode Case no.)
6. Pump or valve Nozzle Check Valve Nominal Inlet slze- 2 Outlet size 2 7nd oin.)
7. Material: Body SA-479 Type 31 6 66e N/A________________

(a) lb) IC) (d) (el Cert. Nat'l Body Bonnet Disx Holder's Board Serial Serial Serial Serial No. No. No. No. No.

11256 None. KNG-001 None KNH-001 11257 None KNG-002 None KNH-002 11258 None KNG-003 None KNH-003 11259 None KNG-004 None KNH-004 11260 None KNG-005 None KNH-005 11261 None KNG-006 None KNH-006 11262 None KNG-007 None KNH-007 11263 None KNG-008 None KNH-008 11264 None KNG-009 None KNH.009 11265 None KNG-010 None KNH-010 11266 None KNG-011 None KNH-01 1 11267 None KNG-012 None KNH-012 11268 None KNG-013 None KNH-013 11269 None KNG-014 None KNH-014 11270 None KNG-015 None KNH-015 11271 None KNG-016 None KNH-016 11272 None KNG-017 None KNH-017 11273 None KNG-018 None KNH-018

  • Supplemental kIformasion In form of lists, sketches. br drawings may be used provided II) size is81 x 11, (2) hinformetion iMItems 1 through 4 on this Data Report Is Included on each sheet (31 each sheet is numbered end the number ot sheets Is recorded at the top of this forn.

112188) This form (E00037) may be obtained from the Order Dept.. ASME, 22 Law Drive. Box 2300. Fairfield. NJ 07007-2300. &9PRINT M3

I AM NPV-1 (Back - Pg. 2 of 2..)

- . .11256 thru Certificate Holder's Serial No. 11273

8. Design conditions _____ 2800__ps___ralvpesur psi 250 e or valve pressure class 1500 11

()

(pressure) (temperaturel 0

9. Cold working pressure 3600 psi at I °F
10. Hydrostatic test 5400 psi. Disk differential test pressure N/A psi
11. Remarks: Oty. 18, Enertech Job Number 29345V CERTIFICATION OF DESIGN Design Specification certified by JohnR.Sponsel, I P.E. State MD Rag. 17308 DesignReport certifiedby Ira J, Silverman p.A.State C eg. no. 23241 CERTIFICATE OF COMPLIANCE We certify that the statements made In this report are correct and that this pump or valve conforms to the rules for construction of the ASME Cods, Section ill, Division 1. ao is __a____

NP Lertrincae As 01 Autnorizalon No. i'i-Z1!5. Expato d 1s1 1/Ut Date _____ _0__3 Nsame Enertd Oiv. d CuLs.Wrd Fow Convol Corp. Signed , a IN Certificate Holder) (authoriecd represuntatva)

CERTIFICATE OF INSPECTION 1, the undersigned. holding a valid commission issued by the Nationsl Board of Boler and Pressure Vessel Inspectors and the State or Province of Califoia and employed byHSBCT of Connecticut have inspected the pump, or valve, described in this Data Report on

! /i / . &@ , and state that to the best of my knowledge and belief, the Certificate Holder has con-structed this pump, or valve, In accordance with the ASME Code, Section Ill, Division 1.

By signing this certificate, neither the Inspector nor Nis employer makes any warranty, expressed or Implied, concerning the component described in this Data Report; Furthermore, neither the Inspector not his employer shall be liable ln any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.

Date - £6'0S Signed 4. Com rnmisaions eav1go  ; 04 % A/

(Authorized Inspector) INafl. Bd.lncl. endorsements) and state or prov. and no.]

(I) For manually operated valves only.

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl

1. Owner. Calvert Cliffs Nuclear Power Plant, Inc. Date: 6/1512004 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet I of 2-.

(address)

2. Plant: Calvert Cliffs Nuclear Power Plant Unit: One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-022b, MWO No. 1200205233 (address) (P.O. no., job no., etc.)

Type Code Symbol Stamp: NIA

3. WorkPerformedby- Calvert Cliffs Nuclear Power Plant Dept.

(name) Authorization No.: N/A Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section Xl Class: Two (address)

4. Identification of System: System Number 041 System Name: Chemical Volume Control 5.(a) Applicable Construction Code and Class: ASME B31.7 1969 Edition, Sum. 1971 Add; Class 2 (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition
6. Identification of Components Repaired or Replaced and Replacement Components: - ASME Repaired,. Code Name of Name of Manufacturers National Other Year Replaced. oI Stamped Componet Manufacturer Serial Number Board No. Identification Built Replacemen (Yes or No)

Piping System Bechtel 2" CC-7-1001 N/A #11 Charging Pump Discharge --- 1975 Repalred/Repi No Piping aced Pipe DuBose National 400298 Ht#: 8324H N/A Pipe, 2 In., Sch. 160, ASME SA- 2000 Replacement No Energy Services 376, Tp. 316 Inc.

Insert Reducer DuBose National 54906-GX Heat NIA Reducer, Insert, 2 In.X 3/4 In., 1992 Replacement No Energy Services Code: DVE 6000 lb, Socketweld, ASME SA-Inc.' 182, Gr. F316 Tee DuBose National 54906-GX Heat N/A Tee, 2 In, 6000 lb., Socket Weld, 1992 Replacement No Energy Services Code: BV ASME SA-IS2, Gr. F316 Inc.

Nut Mackson Inc. 400066 Heat Code: N/A Nut, Heavy Rex, 7/1 In.X 9 TPI, 2000 Replacement No JIX ASME SA-194 Gr. 2H Ailthread Rod Mackson Inc. 410155 t#: S20751 NIA Rod, Allthread, 7/8 In. X9 TPI, 2003 Replacement No ASME SA-193 Gr. B7 Flange DuBose National 409374 Ht. Code: N/A Flange, 2 In., 1500 lb., Large 2003 Replacement No Energy Services BEZ Tongue, Socketweld, ASME SA-Inc. 182, Gr. F316

7. Description of Work:

This plan was for the work, piping, fittings, hanger supports and fasteners needed to support the replacement of 1-CKVCVC-165 and IHVCVC-166, #11 Reactor Coolant Charging Pump discharge Check Valve and Isolation valve.

8. Tests Conducted: Hydrostatic:[] Pneumatico Nominal Operating Pressure: Inservice: 6 Leakage: l Functional: El Pressure: 2400 psi. Test Temperature: 115 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) information in Items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is

SheetQof 2-FORM NIS-2 (Back)

9. Remarks:

A Section Xl System Inservice Test of the affected component was Perforrned during the system

,nneditnnc lichmte in comi-inn 8. nf this nannrt

~ , ,,...-

we. ., , v. - vex U s, v<

CodefCaseQ~

ou. --

Eut Nt11-2l-

. -v-~

wasQ e ..

invotkned

,-1vt..-.-

tam -,9.-v3isfv s v Sat~ion Yl I I.

reauired Dressure tests. Addtional Section III Examinations were Derformed (as applicable) to satisfy Code Case N-416-2 and Re-q.Guide 1.147.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this ReoalrlReolacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H. Ballard Signed: Engineering Technician Date: 6/15/2004 Owner or Ownei's D~sijiiee Title '

Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors I and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described inthisOwner'sReportduringtheperiod 7- OY-o3 to 6-/0O1 . and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section M.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

bosIhJ AJO.-2USd Pt -7Em -I-< Commissions: AJ813 9t; ,/ D i/;7/ , A4IV Inspecto's Signature National Board, State, and Endorsements Date: 6 -/6 200-Y

. i v - -'4 FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xi

1. Owner: Calvert Cliffs Nuclear Power Plant, Inc. Date 611512004 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet I of 2 (address)
2. Plant: Calvert Cliffs Nuclear Power Plant Unit: One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-022c, MWO No. 1200205233 (address) (P.O. no., job no., etc.)
3. Work Performed by: Calvert Cliffs Nuclear Power Plant Dept. Type Code Symbol Stamp: N/A (name) Authorization No.: N/A Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class: Two (address)
4. Identification of Systern SystemNumber 041 SystemName: Chemical Volume Control
5. (a) Applicable Construction Code and Class: ASME Draft Code for Pumps & Valves, 1968 Edition, March 1970 Add; Class 2 -

(b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition

6. Identification of Components Repaired or Replaced and Replacement Components: ASME Repaired, Code Name of Name of Manufacturers National Other Year Replaced, ot Stamped Componet Manufacturer Serial Number Board No. Identification Built Replacemen (Yes or No)

Valve Velan Engineering 1-HVCVC-166 N/A #11 Charging Pump Discharge 1975 Repaired/Repi Yes Co. IsolatIon Valve aced Gate Valve Framatome ANP 400425 SN: 001028-1 N/A Valve, Gate, 2 In. 1690 lb.; ASME 2001 Replacement Yes Inc. SA-132 Gr. F316

7. Description of Work:

This plan was for the replacement of 1-HVCVC-166, #11 Charging Pump Discharge Isolation Valve.

8. Tests Conducted: Hydrostatic:[] PneumaticCl Nominal Operating Pressure: Inservice: El Leakage: W Functional: 1 Pressure: 2400 psi. Test Temperature: 115 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 1 I in., (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section Xl Svstem Leakaae Test of the affected component was performed during the system cnnditions listed in section 8. of this report. Code Case N-416-2 was invoked to satisfy Section XI reauired pressure tests. Addtional Section III Examinations were Derformed (as applicable) to satisfy Code Case N416-2 and Reci.Guide 1.147.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this RepalrlReplacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamnp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H.Ballard Signed: A4740 xYi' Engineering Technician Date: 6/15/2004 Owner or Own sibnee, Titedi Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period 7 -A -o 3 to C -/p '- , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures descnbed in this Owner's Report in accordance with the requirements of the ASME Code, Section Xa.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's ReporL Furthermore, neither the Inspector nor his -

employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

ach4-e A . stH4-P/1124 r/azw Atiz-

D i+AJl &77-&2S _ Commuissions: flJr6 9 {5 1, Ate //'7/ , A///1 1o N t n B r-7dA , State a E Inspector's Signature National Board, State, and Endorsemnents Date: 6& /6 200

£ DATA PACKAGE NO. 001028 FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES

  • As Required by the Provisions of the ASME Code,Section II, Division 1 Pg. 1 of -. 2.
1. Manufactured and certified by VELAN iNC. 2125 WNRD AVE.MONTREAL.OUEEBC CANADA g4KlT6 (ncame and address of N Certillcate Holder)
2. Wanufactured for FRAMTO1ME TECOLOGIES 3315-A OLD ZOItEST RD.LYXCHB1TRG.VA.IJSA 24501 (name and address of purchaser)
3. Location of installion -IA (name and address)
4. Model No., Series No., or Type: GAT Drawing PI-76800-N22 Rev E CRN_ ./A
5. ASME Code, Section II, Division 1: 1989 .OQ. I (edition) (addenda date) (class) (Code Case no.)
6. Pump or valve VALVE Nominal inlet size 2._.2Outlet size 2 (In.) -('n.)
7. Material: Body, SA-182.F316 BonnetSA-182.7316 Disk SA-351.CP8M Bolting SA-194.8M SA-564,630H1100 (a) (b) (c) (d) (e)

Cert. Nat'l Body Bonat Disk

'Holder I s Board Serial Serial Serial Serial No. NO. No. NO. No.

001028-1 N/A . R/C:CX !c: ZA E/C: 750 a001028-2 CAK I 75G 001028-3 YZA 750 C01028-4 CAX YZA 75G 001028-5 CAK FZA 750 OC1028-6 CUX FZA 1?

uu=== ===

=N v

_ _m

_I

.P - -

_i Supplemental Information hI form of rists, sketches, or drawings may be used provi'ded (1)slfe Is 1/2 x ll,(2) Information In Items 1 through 4on is Data Report Is Included on each sheet, (3)each shest Is numbered and the number of sheets Is recorded at the top of this form.

(12/38) Ths form (E00037) may be obtained trom the Order Dept, ASME, 22 LAW DRIVE< BOX 2300 Fatrield. NJ 07007-2300.

-' .t@¢t w PAGE 3 OFsA  ;:w

FORM NPV-1 (Back - Pg. 2' 6f 2 )

Certificate [older's Serial No. 001028

8. Design conditions 4055 psi 100 *F or valve pressure class 1690 (12)

(pressure) (temerature)

9. Cold working pressure 4055 psi at 100F7
10. Hydrostatic test 6350 psi. Disk differential test pressure 4650 psi Remarks: MATSERIALS MEET AS= SECTION II EDITION: 1989 ADDENDA: NONE C:RTIF}CATI OF CONTLXANCE We certify that the statements made in this report are correct and that this pump or valve conforms to the rules for construct'on of the ASME Code,Section III, Division 1.

N Certificate of Authorization No. N-2797-1 3xp Date OCT I A XOI1_ Name VELAN NC. Signed (NCertificate Holder) uhorind repr tie)

CERTIFICATZ OF INSPECTION -

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of OUBBSC and employed by REGIZ DU BATIMENT a c I OUEBEC / have inspected the pump, or valve, described in this Data Report on U*t4.O4 /lO' O , and state that to the best of my knowLedge and belief, the Certificate Holder has .onstructed *this pump, or valve, in accordance with the AS1H Code, Section I1, Division 1.

By signing this certificate, neither the inspector nor his employer makes any warrenty, expressed or implied, concerning the component described in this Data Report. Furthermor.,

neither the inspector nor his employer shall be liable in any mamaar for any personal injury or propert, damage or a loss of any kind arising from or -connected with this inspection.

Date signed NZL__

o=1issions 0t3BEC J. MARCHAND Q QC #

871 .4

/ ~t d Inspector) 3 (Nat'L Bd (f~tciE D u QUt

_ _ ( / 1/ stre or prov. andano.) _ ,, ._ .

(1) For manually operated valves only. . arri .

t " _ . .7 -..

rP~~n$ -L4. -SL

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required by the Provisions of the ASMt Code Section Xl

1. Owner: Calvert Cliffs Nuclear Power Plant, Inc. Date: 6/1612004 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet I of 2 (address)
2. Plant: Calvert Cliffs Nuclear Power Plant Unit: One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-052a, MWO No. 1200205235 (address) (P.O. no-,job no., etc.)

Type Code Symbol Stamp: N/A

3. Work Performed by: Calvert Cliffs Nuclear Power Plant Dept. Authorization No.: N/A (name)

Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class: Two (address)

4. Identification of System: System Number 041 SystemName: Chemical Volume Control 5.(a)ApplicableConstructionCodeandClass: ASME Draft Code forPumps & Valves, 1968 Edition, March 1970 Add; Class 2 (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition
6. Identification of Components Repaired or Replaced and Replacement Components: ASME Repaired, Code Name of Name of Manufacturers National Other Year Replaced, oi Stamped Componet Manufacturer Serial Number Board No. Identification Built Replacemen (Yes or No)

Valve Velan Engineering SN: 8370 N/A #13 Charging Pump Discharge 1975 Repaired/Repi Yes Co. Check Valve aced Check Valve Enertech Inc. 408934 SN: 11271 N/A Valve, Nozzle Check, 2 In., 1500 2002 Replacement Yes lb, Large Groove connections, Enertech, Tp. KRV (Mark#

212M3N)

7. Description of Work:

This plan was for the replacement of 1-CKVCVC-177, #13Charging Pump Discharge Check Valve.

8. Tests Conducted: Hydrostatic:E Pneumatics Nominal Operating Pressure: Inservice: E Leakage: E Functional: 1-Pressure: 2352 psi. Test Temperature: 17 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2f M2

.5_h FORM NIS-2 (Back)

9. Remarks:

A Section Xi System Leakage Test of the affected component was performed during the system conditions listed in section 8. of this report.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this RepairlReplacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H.Ballard Signed: Engineering Technician Date: 6/16/2004 Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period 9 - AD-03 to ( -/0 - OY . and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XM.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

>7O"J AKJI-&S Pew Commissions: A113 9&3) / 1//7/1 14//1 A -,,/ at ,7 o AD A , Insoector's Signature National Board, State, and Endorsements Date: (O '/ 200 9

i. - I %

FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES*

As Required by the Provisions of the ASME Code,Section III, Division I Pg. 1 of 2

1. Manufactured and certified by Enertech, A Div. of Curtiss-Wright Flow Control Corp., 2950 Birch St., Brea, CA 92821 Iname end addresi of N Cirtiflcate Holder)
2. Manufactured for Calvert Cliffs Nuclear Power Plant, PO Box 17323, Baltimore, MD 21297-1323 (name and address of Purchaser)
3. Location of InstallatLon Calvert Cliffs nuclear Power Plant; 1650 Calvert Cliffs Parkway, Lusby, MD 20657 (name and address)
4. Model No.. Series No., or Type KRV Drawing MD20990 Rev. A CRN None
6. ASME Code, Section- iP,Division 1: 1995 1996 1 NQne iedition) laddenda date) (class) (Code Case no.)
6. Pump or valve Nozzle Check Valve Nominal Inlet aize 2 Outlet size 2 On.) oin.)

7.Material: Body SA49Tye3 6rionet N/ADisk SA-479Tye316 Bolting NA la) (b) Ic) (d) (el Cort. Nat'l Body Bonnet Disk Holder's Board Serial Serial Serial Serial No. No. No. No. No.

11256 None KNG-001 None KNH-001 11257 None KNG-002 None KNH-002 11258 None KNG-003

  • None KNH-003 11259 None KNG-004 None KNH-004 11260 None KNG-005 None KNH-005 11261 None KNG-006 None KNH-006 11262 None KNG-007 None KNH-007 11263 None KNG-008 None KNH-008 11264 None KNG-009 None KNH-009 11265 None KNG-010 None KNH-010 11266 None KNG-011 None KNH-011 11267 None KNG-012 None KNH-012 11268 None KNG-013 None KNH-013 11269 None KNG-014 None KNH-014 11270 None KNG-01 5 None iKNH-015 11271 None *KNG016 None KNH-016
  • 11272 None KNG-41 7 None KNH-017 11273 None KNG-018 None KNH-018
  • Supplemental Information In form of Uts. sketches. br drawings may be used provided (1 size Is 8% x 11, W2Information In Items 1 through 4 on this Data Report is Included on each sheet. 131each sheet Is numbered and the number ot sheets Is recorded at the top of this torn.

(IV88) This form 11200037) may be obtained from the Order Dept.. ASME. 22 Law Drive, Box 2300. Fairfield, NJ 07007.2300. IMPRINT as

.M NPV-t1Back-.Pg. 2 of 2 l 11256 thru Certificate Holder's Serial No. 11273

8. Design conditions 2800 Psi 250 For valve pressure dass 1500 (1)

Ipressure) Itemperaturel

9. Cold working pressure 3600 psi at 1001F
10. Hydrostatic test 5400 psi. Disk differential test prassure N/A 1i. Remarks: Oty. 18, Enertech Job Number 29345V CERTIFICATION OF DESIGN Design Specification certified by John R. Sponsel, II P.E. State MD Reg. no. 17308 Design Report certified by Ira J. Silverman P.E. State CA Reg. no. 23241 CERTIFICATE OF COMPUANCE We certify that the statements made in this report are correct and that this pump or valve conforms to the rules for construction of the ASME Code,Section III, Division 1.

N Certificate of Authorization No. N-2826 Exp>, 10/11/05 Datea/4/3 -Name Enenled AOiv. Curss-Wrht sFbWCa p.

orCO Signed I 6 A T INCertificate Holder) (authorized represuntatlvel CERTIFICATE OF INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of tateor the ofandemployed California Povine and by HSB CT of Connecticut have inspected the pump, or valve, described in this Data Report on l - if. '

  • and state that to the best of my knowledge and belief, the Certificate Holder has con-structed this pump, or valve, In accordance with the ASME Code, Section Ill, Division 1.

By signing this certIficate, neither the inspector nor his employer makes any warranty, expressed or Implied, concerning the component described in this Data Report Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.

Date 1'bt-@0Signed Ag PŽ.P W icosmissions 'A/9'2 P (Authorized Inspector) INati. 8d. (lncLendorsernents) and stme or prov. and no.1 (1) For manually operated valves only.

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl

1. Owier: Calvert Cliffs Nuclear Power Plant, Inc. Date 611612004 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet I of 0-(address)
2. Pl Calvert Cliffs Nuclear Power Plant Unit: One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-052b, MWO No. 1200205235 (address) (P.O. no., job no., etc.)
3. WorkPerformedby: Calvert Cliffs Nuclear Power Plant Dept. Type Code Symbol Starnp: N (name) AuthorizationNo.: N/A Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section X Class: Two (address)
4. Identification of System: System Number 041 System Name: Chemical Volume Control 5.(a)ApplicableConstructionCodeandClass: ASME B31.7 1969 Editlon, Sum.1971 Add; Class 2 (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition
6. Identification of Cornponents Repaired or Replaced and Replacement Components: ASME Repaired, Code Name of Name of Manufacturers NBational Other Year Replaced, ox Stamped Cornponet Manufacturer Serial Number Bo ard No. Identification Built Replacemen (Yes or No)

Piping System Bechtel 2" CC-7-1003 NtA #13 Charging Pump Discharge 1975 Repaired/Repl No Piping aced Pipe DuBose National 400298 Ht.#: 8324H N/A Pipe, 2 In., Sch. 160, ASME SA- 2000 Replacement No Energy Services 376, Tp. 316 Inc.

Insert Reducer Energy & Process 411138 Heat Code: N/A Reducer, Insert, 2 In. X 1 In, 6000 2003 Replacement No Corporation EM6S lb., Socketweld, ASME SA-182, Gr. F316.

Tee DuBose National S4906-GX Heat N/A Tee,21In, 6000 lb., Socket Weld, 1992 Replacement No Energy Services Code: BV ASME SA-182, Gr. F316 Inc.

Nut Mackton Inc. 408227 Ht.#: S44018 N/A Nut, Heavy Hex, 7/8 in. X 9 TPI, 2002 Replacement No ASME 6A-194 Gr. 2H Allthread Rod Mackson Inc. 410155 Ht#: S20751 NIA Rod, Allthread, 7/MIn. X 9 TPI, 2003 Replacement No ASME SA-193 Gr. B7 Flange DuBose National 409374 Ht. Code: NIA Flange, 2 In, 1500 lb., Large 2003 Replacement No Energy Services EHI Tongue, Socketweld, ASME SA-Inc. 182, Gr. F316 Coupling Ladish Co. F-8588 Heat Code: N/A Coupling, 2 In., 6000 lb., ASTM A- 1973 Replacement No D6MG H 182, Gr. F316 Pipe Strap Anvil International 34757 Lot#: 17925 N/A Strap, Pipe Guide, 2 In., for PG- 1999 Replacement No Inc. Grlnnell 44, BGEDRWG FSK-MP-Supports 0571SH 0005 & 6, Item #2

7. Description of Work:

This plan was for the work, piping, fittings, hanger supports and fasteners needed to support the replacement of 1-CKVCVC-177 and 1HVCVC-178, #13 Reactor Coolant Charging Pump discharge Check Valve and Isolation valve.

Sheet 2 of 2 FORM NiS-2 (Back)

8. TestsConducted: Hydrostatic:O Pneumatics Nominal Operating Pressure: Inservice: Leakage:Eo Functional:O Pressure: 2352 psi. Test Temperature: 1 17 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of {his form.
9. Remarks:

A Section Xl System Leakage Test of the affected component was Performed during the system conditions listed in section 8. of this report. Code Case N-416-2 was invoked to satisfy Section Xl required Pressure tests. Addtional Section III Examinations were performed (as applicable) to satisfy Code Case N-416-2 and Rea.Guide 1.147.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Repalr/Reolacement conforms to the rules of the ASME Code, Section XM.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H.Ballard Signed: Engineering Technician Date: .6/16/2004 Owner or il awesDsgne Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board ofBoiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period 9 -AN- 0 5 to 6 -/&)- / and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XM.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or

-- c-rined-CStlhisi -I -- espection. _ .7-TL)4o-J AMILX Pe 7Z/'1 Commissions: l'S W3/,AI,9//7/ 1 A4iJ//

Insoector's Signature National Board, State, and Endorsements Date: 6 - / 7 - 200if

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xi

1. Owner: Calvert Cliffs Nuclear Power Plant, Inc. Date: 6117/2004 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet 1of 2 (address)
2. Plant: Calvert Cliffs Nuclear Power Plant Unit: One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-052c, MWO No. 1200205235 (address) (P.O. no., job no., etc.)
3. Work Performed by: Calvert Cliffs Nuclear Power Plant Dept. ype Code Symbol Stamp: N/A (name) Authorization No.: N/A Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class: Two (address)
4. Identification of System: System Number 041 SystemName: Chemical Volume Control
5. (a)Applicable Construction Code and Class: ASME Draft Code for Pumps & Valves,1968 Edition, March 1970 Add; Class 2 (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition
6. Identification of Components Repaired or Replaced and Replacement Components: ASME Repaired, Code Name of Name of Manufacturers National Other Year Replaced, oi Stamped Componet Manufacturer Serial Number Board No. Identification Built Replacemen (Yes or No)

Valve Velan Engineering 1-HVCVC-178 N/A #13 Charging Pump Discharge 1975 Repalred/Repi No Co. Isolation Valve aced Gate Valve Vendor. BWNS 70390LNP SN: N/A Valve, Gate, 2 In. 1690 lb.; ASME 1994 Replacement Yes Nuclear 941005-1 SA-182 Gr. F316 Mfgr: Velan Engrg. Co.

7. Description of Work:

This plan was for the replacement of 1-HVCVC-178, #13Charging Pump Discharge Isolation Valve.

& TestsConducted:-- -Hydrostatic:E]-- Pneumaticfl -NominalOperatingPressure- -- Inservice:--Leakage: --Functional: -- -

Pressure: 2352 psi. Test Temperature: 117 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x I I in., (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet2of 2 FORM NIS-2 (Back)

9. Remarks:

A Section XI System Leakaae Test of the affected comoonent was cerformed durina the system conditions listed in section 8. of this report. Code Case N-416-2 was invoked to satisfy Section Xl required pressure tests. Addtional Section III Examinations were performed (as applicable) to satisfy Code Case N-416-2 and Rea.Guide 1.147.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Repair/Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H.Ballard Signed: ;0 Engineering Technician Date: 6/17/2004 Owneror Owner's Designee,Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period ' X;L-c3 to (V /0 - 1V7 , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

Do) AJAfi) A - S94-7'),4 iFtKL ,(l/Z sow Womits Pk' iff Commissions: /JIq'3/, ,qO 1/7/ 44V//

aio77

/ l oa0 Sae ad Inspector's Signature National Board, State, and Endorsements Date: 6_-_/_7 200-S

  • e AR\\toS FORM NPVY 1CERTIFIC. - HOLDERS' DATA REPORT FOR NUCLL. PUMPS OR VALVES*

As Required b, .e Provisions of the ASME Code. Sectio( Division 1 Pg. 1 of -

1. Manufactured and certified by \ . '\Y& NQ It.& \i\, .

(name and address of N Certificate Holderl

2. Manufactured for Lvtii9& SRXN\_O fi_

Ename and address of Purchaser)

3. Location of Installation .

(name-VW address)

4. Model No., Series No., or Type GF,. Drawing\ '. Rev. 6CR
5. ASME Code. Section 111. Division 1: \°!°.4 . C (addenda datel

. (class)

Coda Cse no.)

lditiont

6. Pump or valveo . . Nominal inlet size Outlet size v
7. Materbl: Body Bonnet Dkk Bolting Bi6XqC W la) (1b IC) Id; (a)

Coet. Nat'I Body 8onnet Disk Holders Board Serial senra 4.,i , Serial Serial No. No. No. No - No.

9i\ObSW \ tbW t As-etll.%

i ' \ B~t -?

. ~ ~~ ~ ~ ~ CC ~ S: ~ ~-V C.S - f, 41\

  • Supplemental informraon inform of Hats. skitcas, or drawvngs may be used provided 111 ize s 8 X 11. (21 information In items 1 through 4 8 on tis Dot Rport IsIncluded on each sheet. 13) each sheet Isnumbered and the number ol shaots Is reco,rded at the top of this form.

112188) This form (E00037) may be obtained from the Order Dept.. ASME. 22 Law Drive B,ox 2300. Farfield. NJ 07007-2300.

[ PA E PPF~

ORM NPV-1 (Back - Pg. 2 of Certificate Holder's Serial No. -M M B. Design conditions ~AQ 1& psi aF or valve pressur, class Coeneasuraie S. Cold working pressure - ~A psi at wo00F IO. Hydrostatic test (aii 1lso... psi. Disk differential test pressure Wa^psi 1 1. Remarks: Anl~% U SY\ ai A X.SS~ I CERTIFICATION OF DESIGN Design Specification certified by Design Report catfe by -

-'& NJ.

4ak\"%

pi.EStateDO S

'e.n.MQ

1E CERTIFICATE OP COMPLIANCE We certify that the statements made in this report are correct and tht this pump at valve conforms to the rules for construction of the ASME Cods, Section Iii, Division 1.

Os A '

A kpL w N Certificate of Authorization No. Expires Dat amNin INCactifleate

\'inCo Hodder Signed lauthoriad reprd~ntative)

CERTIFICATE OF INSPECTION I. the undersigned. holding a valid conjnission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or ifpvince of and employed by of have inspected the pump, or yaive, described in this Data Report on

-q 41-/ g, and state that to the best of my knowledge and belief, the Certificate Holder hies con-structed tWs pump, or valve, in accordance with the ASME Code, Section Ill, Division 1.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the component described In this Data Report. Furthermore, neither the inspector not his employer shall be liable in any maniner for anty personal injury orproperty damage or a loss of any kind arising from or connected with this inspection.

Date 2Ž4~.Signed / lAuthodedzs Intolator)

/'rommissions (Qe ,

Naili. 0d.111vAt. endorsewnantsl and state or praw. and no.1 (II For manually operated valves only.

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xl

1. Owner: Calvert Cliffs Nuclear Power Plant, Inc. Date: 611512004 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet I of 2 (address)
2. Plant: Calvert Cliffs Nuclear Power Plant Unit: One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-077, MWO No. 1200205240 (address) (P.O. no., job no., etc.)
3. Work Performed by Calvert Cliffs Nuclear Power Plant Dept. Tpe Code Symbol Stamp: N/A (name) Authorization No.: N/A Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class: One (address)
4. Identification of System: System Number 064 System Name: Reactor Coolant System 5.(a)ApplicableConstructionCodeandClass: ASME B31.7 1969 Edltion, Sum.1971 Add; Class 1 (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition
6. Identification of Components Repaired or Replaced and Replacement Components: ASME Repaired, Code Name of Name of Manufacturers National Other Year Replaced, oi Stamped Componet Manufacturer Serial Number Board No. Identification Built Replacemen (Yes or No)

Pipe Support Bechtel 2 1/2"CC-10-1003-H3 N/A #11 Pressurizer Pipe Support to 1- 1975 Repalred/Repl No ERV.402 aced Spring Can Anvil International 411825 PN: N/A Support, Constant, Anvil Figure 2004 Replacement No Inc. Grinnell 80VB014-NB SO-V, Size 14, Type B, with Travel Supports Stop, Load - 620 lbs.

7. Description of Work:

This plan was for the replacement of the Spring Can on pipe line 2 1/2"CC-10-1003, Pressurizer Piping to Electric Relief Valve 1-ERV-402, support number H3.

8. Tests Conducted: Hydrostatic:[ PneumaticCl Nominal Operating Pressure: Inservice: E Leakage: M Functional:

Pressure: N/A psi. Test Temperature: N/A Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) information in Items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section Xi VT-3 Visual Examination of the affected component suDDort was Derformed Drior to the system being returned to service.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this ReaalrlReolacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A Signed:

AD S A t,/4 J Charles H. Ballard Engineering Technician Date: 6/15/2004 Owner or Ok~ers- Des-ignee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described inthis Owner's Reportduringtheperiod 39-7-a Y to 6 -3 09Y , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section MI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

bDo&t- A .sn4f/o;" - f 2..

o ' Commissions: A) 8 9 T 3 All /M7/41 1/

setSn Nata B79o/tte ad os

,, Inspector's Signature National Board, State, and Endorsemnents Date: 6 - A -- 2

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xl

1. Owner: Calvert Cliffs Nuclear Power Plant, Inc. Date: 611412004 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet 1 of 2

- (address)

2. Plant: Calvert Cliffs Nuclear Power Plant Unit: One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-078, MWO No. 1200205247 (address) (P.O. no., job no., etc.)

Type Code Symbol Stamp: N/A

3. Work Performed by: Calvert Cliffs Nuclear Power Plant Dept. Authorization No.: N/A (name)

Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section X1 Class: One (address)

4. Identification of System: SystemrNumnber 064 System Name: Reactor Coolant System S.(a) Applicable Construction Code and Class: ASME 631.7 1969 Edition, Sum. 1971 Add; Class I (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition
6. Identification of Components Repaired or Replaced and Replacement Components: ASME Repaired, Code Name of Name of Manufacturers National Other Year Replaced, oi Stamped Comnponet Manufacturer Serial Number Board No. Identification Built Replacemen (Yes or No)

Pipe Support Bechtel 2 1/2"CC-10-1004-H3 N/A #11 Pressurizer Pipe Support to 1- 1975 Repalred/Repl No ERV-404 aced Spring Can Anvil International 411825 PN: N/A Support, Constant, Anvil Figure 2004 Replacement No Inc. Grlnnell SIHCO15-NB 81-H- SIze 15, Type C, with Supports Trave Stop, Load - 725 lbs,

7. Description of Work:

This plan was for the replacement of the Spring Can on pipe line 2 1/2"CC-10-1004, Pressurizer Piping to Electric Relief Valve 1-ERV-404, support number H3.

8. Tests Conducted: Hydrostatic:[J Pneumatico Nominal Operating Pressure: Inservice: E Leakage: E Functional: 0 Pressure: N/A psi. Test Temperature: N/A Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (I) size is 8-1/2 in. x 11 in., (2) information in Items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section Xi VT-3 Visual Examination of the affected component supp~ort was Derformed Porior to the system being returned to service.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Repalr/Repiacement conforms to the rules of the ASME Code, Section X1.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H.Ballard Signed: .ignee, Tf Engineering Technician Date: 6/14/2004 Owner or Owneiresignee le Certificate of Inservice Inspection 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period 3 -/ 7 0 3" to 60 / , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with inspection.

Aot. az7f)1J AJ7W Z/S fA)Z 7~Z6-t

>z- /i--LOY- Commissions: MJ ?83/. MO //7/. /X//

V,6l /I77cf WV //3'S

.. .. National Board, State, and Endorsements Date: 4 _/,y/ 4r-v.oo 0e

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl

1. Owner: Calvert Cliffs Nuclear Power Plant, Inc. Date: 611612004 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet I of 2 (address)
2. Plant: Calvert Cliffs Nuclear Power Plant Unit: One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-023a, MWO No. 1200205332 (address) (P.O. no., job no., etc.)

Type Code Symbol Stamp: N/A

3. Work Performed by: Calvert Cliffs Nuclear Power Plant Dept. Authorization No.: N/A (name)

Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class: One (address)

4. Identification of System: System Number 064 System Name: Reactor Coolant System 5.(a) Applicable Construction Code and Class: ASME Draft Code for Pumps & Valves, 1968 Edition, March 1970 Add; Class`1-(b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition
6. Identification of Components Repaired or Replaced and Replacement Components: ASME Repaired, Code Name of Name of Manufacturers National Other Year Replaced, Oz Stamped Componet Manufacturer Serial Number Board No. Identification Built Replacemen (Yes or No) 1975 Repaired/RepI Valve Velan Enginnering SN: 155 NIA Pressurizer Isolation Block Valve 1975 Repaired/Repl Yes Co. for I-ERV-402 aced Gate Valve Flowserve 405820 SN: E506T- NIA Valve, Gate, 2 1/2 In., 1703 lb., 2002 Replacement Yes Corporation 1-1 Sch. 160 Buttwelded, Flowserve P/N W01-25821, ASME SA-351 Gr. CF8M
7. Description of Work:

This plan was for the replacement of 1-MOV-403, #11 Pressurizer Isolation Block Valve for 1-ERV-402.

8. Tests Conducted: Hydrostatic:r PneumaticO Nominal Operating Pressure: Inservice: E Leakage: i- Functional: a Pressure: 2260 psi. Test Temperature: 660 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) information in Items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 a.2,z 0FORM NIS-2 (Back)

9. narks: . ........ _ _ _ _

A Section Xl VT-1 Visual Examination of the replacement threaded fasteners was performed to satisfy Section Xl Pre-Service NDE Requirements. A Section Xl System Leakage Test of the affected component was performed during the system conditions listed in section 8. of this report. A Section XI Surface Examination of the affected component was performed to satisv Section XI Pre-Service Requirements.

Code Case N-416-2 was invoked to satisfy Section Xl required pressure tests. Addtlonal Section III Examinations were performed (as applicable) to satisfy Code Case N-416-2 and Req.Guide 1.147.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Repalr/Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H. Ballard Signed: 4 W9 9 Engineering Technician Date: 6/16/2004 Owner or Owners Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period /2 - A to -.;2) -o*' , and state to the best of my knowledge and belief; the Owner has performedexammations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

D0-JA*-t0 A SNA-ib^4 1-v-L 4R1 p.

Zroj" AIDDDS, p Amp Commissions: 16 9&3/ 1AD //7/ X441//

IVJ5 1A77 51 Af O /,'5..

- Ins~netnr's Sirntum National Board, State, and Endorsements Date: & /77 2000

?<,- 0, FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES*

As Required by the.Provlslons of the ASME Code; Section Iil, Division 1

  • ---. Pg. 1 of 2 j
1. Manufactured and certified by Flowserve Corporation, 701 First Steeti Williamsport, PA 17701 Iname and address of N Certificate Holder)
2. Manufactured for Constellation Nuclear, P.O. Box 1609, Lusby, MD 20657

[name and address of Purchaser)

3. Location ot installation CCNPP, 165Q Calvert Cliffs Parkway, Lusby, MD 20657 (name and address)
4. Model No., Series No., or Type D.D. Gate Drawing W0125821 Rev. A CRN NIA

'S. ASME Code, Section 111.Division 1: 1995 1996 I N/A (edition) (addenda date) cl(ssi (Code Case no.)

e. Pump or valve' Valve Nominal Inlet size 2 1/2" Outlet size 2 l1l" 7.Material: Body SA35l-CF8M Bonnet SA351-CF8M Disk Dolting SA479-316 Bolt,', Studs: SA453-660B Nuts: SA194-8M (a) (bl ic) (d) (e)

Cart. Nat'l Body - Bonnet Disk Holder's Board Serial Serial Serial Serial No. No. No. No. No.

E506T- 1-1 N/A 'RI5 R21 6 and 19 E506T-1-2 N/A R16 R19 5 and 18 E506T-1-3 *N/A R17 R20 7and20 E506T- 14 NYA R18 - R22 8 and 21 '

. . M

.. .O ff informatIon form of lists.

Suppiemental in or drawings may be used provided (1)aIze is 8 if, x II, (21 Information Initerns 1 through 4 sketches,

'Supple montal Inforumationl In form of lists, sketches, or drawings may be used providedII size Is1S K X 11l, 12) Informaton WIntern I through 4 on this Oata Report is Included on each sheet. (31 each shast Is numbered and the number of sheets Is recorded at the top of this form.

Ii2t8di This form (!000371 may be obtained fron the Order Dept., ASME, 22 Law Drive, Box 2300, Fairfield, NJ07007-2300. REPRJNTSU93

FORM NPVY1 (Back - Pg. 2 of 2..

CertificatelHoIlder'i SrialNo. E506T1-1 thru 4 S. Design conditions 2485 psr 675 eF or valve pressure class 1703 (pressure) (temperature)

9. Cold workingpressure 4087 psi at 100WF
10. Hydrostatic test pstL Disk differenttal test pressura - 4500

-61 psi

11. Re k: Maiterial: Bonnet Stads: (30) Trace Code E621 (2) Trace Code B719 Bonnet Nuts: (23) Trace Code TSK (9) Trace Code A288 I

CSRTIFICATION OF DESIGN Design Specification certified by John EL Spowel P.E. State MD Reg. no. 17308 Design Report certified by Ronald S. Farreff P.E. State PA Fleg. no. PE-0352 16-E I .

CERTIFICATE OF COMPUANCE We certify that the statements made Inthis report are correct and that this pump or valve conforms to'the rules for construcifon of the ASME Code, Section Ili, Division 1.

N Csrtifica o ot Authortzatlon No. N712 - - .- a Flowserve Cotporation INCertificate Holderl uthorized rs$senthval CERTIFICATE OF INSPECTiON i the undersigned, holding a valid commission Issued by the National Board of 3oller and Pressuri Vessel Inspectors and the Statu 6MVIM of Pennsvlvania and employed by One Beacon America Insurance at Boston. Mass. have Inspected the pump, or valve, described In this Data Report on I-/57 O0--J 3.

  • and state that to the beat of my knowledge and belief, the Certificate Holder has cont structed this pump, or valve, In accordance with the ASME Codas Section ill, Division 1.

By signind this cetficate, neither the Inspector nor his employer makes any warranty. expressed or Im 1fed con component described In this Data Report. Furthermore, neither the Inspector nor his eamployer ihal be liable in any er any personal Injury or proper a r at Itany kind arising from or connected with this Inspection.

Date 43C Slgne '~ mmrbasona Pennsylvania 2392 9 Cha~vrellt2t 0 INat'l. sd. fInd. endorsammntsi and stUs or prov. and no.J (11 For manually eperatid valves only..

FORM NIS-2 OWNER'S REPORT FOR REPAIR I REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xi

1. Owner: Calvert Cliffs Nuclear Power Plant, Inc. Date: 611612004 (name) 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Sheet I of 2 (address)
2. Plant: Calvert Cliffs Nuclear Power Plant Unit: One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-023b, MWO No. 1200205332 (address) (P.O. no., job no., etc.)

Type Code Symbol Stamp: N/A

3. Work Performed by: Calvert Cliffs Nuclear Power Plant Dept.

Authorization No.: N/A (name)

Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class: One (address)

4. Identification of System: System Number 064 System Name: Reactor Coolant System
5. (a) Applicable Construction Code and Class: ASME B31.7 1969 Edition, Sum. 1971 Add; Class 1 (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition
6. Identification of Components Repaired or Replaced and Replacement Components: ASME Repaired, Code Name of Name of Manufacturers National Other Year Replaced, oi Stamped Componet Manufacturer Serial Number Board No. Identification Built Replacemen (Yes or No)

Piping System Bechtel N/A N/A #11 Pressurizer Piping to l-MOV- 1975 Repaired/Repi No 403 aced Pipe DuBose National 410658 Ht.#: PZ278 N/A Pipe, 2 1/2 in., Sch. 160, ASME 2003 Replacement No Energy Services SA-376, Tp. 316 Inc.

Elbow Consolidated 408690 Ht.: F8746 N/A Elbow, Pipe, 2 1/2 In., 90 Deg., 2002 Replacement No Power Supply Sch.160, Long Radius, butt weld, ASME SA403, Gr. WP316 Concentric DuBose National 410658 Ht#: F8791 N/A Reducer, Pipe, Concentric, 4 In. X 2003 Replacement No Reducer Energy Services 2 1/2 in., Sch. 120 X 160, ASME Inc. SA-403, Gr. WP316

7. Description of Work:

This plan was for the piping/fittings in support of the replacement of 1-MOV-403, #11 Pressurizer Isolation Block Valve for 1-ERV-402.

8. Tests Conducted: Hydrostatic:E PneumaticC Nominal Operating Pressure: Inservice: LI Leakage: i Functional: a]

Pressure: 2260 psi. Test Temperature: 660 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) information in Items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section Xi System Leakacie Test of the affected component was performed during the system conditions listed in section 8. of this report. A Section Xl Surface Examination of the affected component was performed to satisv Section Xl Pre-Service Requirements. A Section Xl Ultrasonic Examination of the affected component was performed to satisfy Section Xl Pre-Service NDE Requirements. Code Case N-416-2 was invoked to satisfy Section Xl required pressure tests. Addtional Section III Examinations were performed (as applicable) to satisfy Code Case N-416-2 and Rea.Guide 1.147.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this RepairlReplacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H. Ballard Signed: . Engineering Technician Date: 6/16/2004 Ownero Owneras Lk-fgnee, TitIe Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have-inspected the components described in this Owner's Report during the period /.a - a - 3 to .5- ao -o ,and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XM.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

bob <<D A .Sgw/f /:, /-f2.

R0 1)094L15 Pk -8z- Commissions
AJt 7 & 3 /Vd //7/ '4.V//

n-XauNia AosI oarSate adnr

,_ Insmector's Sisma~ture National Board, State, and Endorsements Date:6 -/7 -. 2003*

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl

1. Owner: Calvert Cliffs Nuclear Power Plant, Inc. Date: 6117/2004 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet 1of 2 (address)
2. Plant: Calvert Cliffs Nuclear Power Plant Unit: One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-024a, MWO No. 1200205334 (address) (P.O. no.,job no., etc.)
3. Work Performed by: Calvert Cliffs Nuclear Power Plant Dept. Type Code Symbol Stamp: N/A (name) Authorization No.: N/A Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class: One (address)
4. Identification of System: System Number 064 System Name: Reactor Coolant System 5.(a) Applicable Construction Code and Class: ASME Draft Code for Pumps & Valves, 1968 Edition, March 1970 Add; Class 1 (b) Applicable Sect )a Ed. for Repairs/Replacement 1998 Edition
6. Identification of Components Repaired or Replaced and Replacement Components: ASME Repaired, Code Name of Name of Manufacturers National Other Year Replaced, oi Stamped Componet Manufacturer Serial Number Board No. Identification Built Replacemen (Yes or No)

Valve Velan Enginnering 154 N/A Pressurizer Isolation Block Valve 1975 Repalred/Repl No Co. for l-ERV-404 aced Gate Valve Flowserve 405820 SN: E506T- N/A Valve, Gate, 2 1/2 In., 1703 lb., 2002 Replacement Yes Corporation 1-2 Sch. 160 Buttwelded, Flowserve P/N W01-25821, ASME SA-351 Gr. CF8M

7. Descripion of Work:

This plan was for the replacement of 1-MOV-405, #11 Pressurizer Isolation Block Valve for 1-ERV-404.

8. Tests Conducted: Hydrostatic:[] Pneumatic{] Nominal Operating Pressure: Inservice: E Leakage: W Functional: E Pressure: 2260 psi. Test Temperature: 660 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (I) size is 8-1/2 in. x 11 in., (2) information in Items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

a 4 01 q Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section Xl VT-1 Visual Examination of the replacement threaded fasteners was performed to satisfy Section XI Pre-Service NDE Requirements. A Section XI System Leakage Test of the affected component was performed during the system conditions listed in section 8. of this report. A Section Xl Surface Examination of the affected component was performed to satisy Section Xl Pre-Service Requirements.

Code Case N416-2 was invoked to satisfy Section Xl required pressure tests. Addtional Section III Examinations were performed (as applicable) to satisfy Code Case N-416-2 and Req.Guide 1.147.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Reoalr[Replacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A Signed: Engineering Technician Date: 6/17/2004 Own forO 4ts-feg-nee, riie Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described inthisOwner'sReportduringtheperiod iB-LD--o3 to 6 - *,- O' , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

Dd)O )4

  • rm 1e40.

So Ivf AJOFZnZIoS EZ 7nct7-r Y Commissions: /A 6 r 3/ , 10,)// 7/ / 4J//

Tn/nc Nta oa7rd, Stateo and Endrsee In-snector's Sionature National Board, State, and Endorsemnents Date: $ - r 2 -- --

FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES*

As Required by the.Provisions of the ASME Code; Section 111,Division 1 Pg. 1 of 2

1. Manufactured and cenified by Flowserve Corporation, 701 First Street, Williamsport, PA 17701 (name and address of N Certificate Holder)
2. Manufactured for Constellation Nuclear, P.O. Box 1609, Lusby, MD 20657 Iname and address of Purchaser)
3. Location of instellation CCNPP, 1650 Calvert Cliffs Parkway, Lusby, MD 20657 (name and addressl
4. Model No., Series No., or Type D.D. Gate arawing W0125821 Rev A CRN N/A
5. ASME Code, Section Ill. Division 1: 1995 1996 1 N/A (editionl (addenda data) Iclassl (Code Case no.)
6. Pump or valve Valve Nominal Inlet size 2 1/2" Outlet size 2 1/2" lin l(in.)

7 Material Body SA351-CF8M Bonnet SA351-CF8M Disk SA479-316 Bolting Studs: SA453-660B Nuts: SA1 94-8M (a) Ib) (ci (d) (el Cert. Nat'l - Body Bonnet Disk Holder's Board Serial Serial Serial Serial No. No. No. No. No.

E506T- 1-1 NIA R15 R21 6 and 19 E506T-1-2 N/A R16 R19 5and 18 E506T-1-3 N/A R17 R20- 7 and 20 E506T- 14 N/A - R18 R22 8 and 21 ziOV

.. .11

  • Supplemental information In form of ists. sketrchas. or drawings may be used provided 111size is 8Ys X 11, (21 information In Iterns I through 4 on this Data Report Is Included on each sheet. 131each sheet Is numbered and the number of sheets Is recorded at the top of this form.

(11/881 This form 1E00037) maybe obtained from the Order Dept., ASME. 22 Law Drive, Box 2300. Fairfield, NJ07007.2300. REPAINT V93

FORM NPV-1 (Back - Pg. 2 of 2 Certificate Holder'i Serial No. E506T-1-1 II= 4

8. Design conditions 2485 psi 675 F or valve pressure class 1703 11 (pressurel Itemperaturel
9. Cold workingpressurs 4087 psi at 100°F
10. Hydrostatic test 6150 psi. Disk differential test pressure 4500 p31
1. Remarks tei: Bonnet Studs: (30) Trace Code E621 (2) Trace Code B719 Bonnet Nuts: (23) Trace Code TSK (9) Trace Code A288 CERTIFICATION OF DESIGN Design Specificaton certified by John R.Sponsel -. PE. State MD Reg. no. 17308 Design Report certdfl d by Ronald S. PafeU P.E State PA eDn.PE-035216-E CERTIFICATE OF COMPPUANCE We certify thatthe statements made in this report are correct and that this pump or valve conforms to'the rules for construction of the ASME Code, Section 111, Division 1.

N Certifica a of Authorization No. N1712 4.15/04 9 AIts Date .j.M.i&.anme AI no Flowserve Corporation Srgned AW (NCerticate Holderl, N. uthorlaed reserntyivel CERlIFICATE OF INSPECTION 1, the undersigned, holding a valid commriss3on Issued by'tha National Board of Boiler and Pressure Vessel Inspectors and the State f 'CA;PM of* PennsvIvania and employed by One Beacon America Insuranco of _Boston. Mass. have Inspected the pump, or valve, described in this Date Report on i-i/i25~6~. &,AO_ and state that to the best of my knowledge and belief, the Certificate Holder has con.

structad this pump, or valve, In accordance with the ASME Code, Saction 111, Division 1.

By signin9 this certificate, neither the Inspector nor his employer makes any warranty' expressed or Implied, con' component described In this Data Report. Furthermore, neither the Inspector nor his employer shall be liable In any ar r any personal Injury or props a a I of any kind arising from or connected with this Inspection.

Date-3-o-od F Pennsylvania 2392 9 adrles 4Ayljzed ictro [iNat'l. Bd. ilnd. endorsemental and state ot prov. and no.)

v .-

(1) For manually operated valves only..

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl

1. Owner: Calvert Cliffs Nuclear Power Plant, Inc. Date: 6/1712004 (name) 1650 Calvert Cliffs Parkway; -Lusby, MD 20657 Sheet I of 2 (address)
2. Plant: Calvert Cliffs Nuclear Power Plant Unit: One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-024b, MWO No. 1200205334 (address) (P.O. no., job no., etc.)
3. Work Performed by: Calvert Cliffs Nuclear Power Plant Dept. ype Code Symbol Stamp: N/A (name) (name)Authorization No.: N/A Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class: One (address)
4. Identification of System: System Number 064 System Name: Reactor Coolant System 5.(a) Applicable Construction Code and Class: ASME B31.7 1969 Edition, Sum. 1971 Add; Class I (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition
6. Identification of Components Repaired or Replaced and Replacement Components: ASME Repaired, Code Name of Nameof Manufacturers National Other Year Replaced, oz Stamped Componet Manufacturer Serial Number Board No. Identification Built Replacemen (Yes or No)

Piping System Bechtel 4'CC-10-1002 NIA #11 Pressurizer Piping to 1-MOV- 1975 Repaired/Repi No 405 aced Concentric DuBose National 410658 Ht.#: F8791 N/A Reducer, Pipe, Concentric, 4 In.X 2003 Replacement No Reducer Energy Services 2 1/2 In., Sch. 120 X 160, ASME Inc. SA-403, Gr. WP316

7. Description of Work:

This plan was for the fitting and work needed to support the replacement of 1-MOV-405, #11 Pressurizer Isolation Block Valve for 1-ERV-404.

8. Tests Conducted: Hydrostatic:E Pneumaticd Nominal Operating Pressure: Inservice: E Leakage: i Functional: 2 Pressure: 2260 psi. Test Temperature: 660 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 a 11b FORM NIS-2 (Back)

9. Remarks:

A Section Xl System Leakage Test of the affected component was performed during the system conditions listed in section 8. of this report. A Section Xi Surface Examination of the affected component was performed to satisy Section Xi Pre-Service Requirements. A Section Xl Ultrasonic Examination of the affected component was performed to satisfy Section Xl Pre-Service NDE Requirements. Code Case N-416-2 was invoked to satisfy Section Xi required pressure tests. Addtional Section III Exarrinations were-performed (as applicable) to satisfy Code Case N-416-2 and Rea.Guide 1.147.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Repalr/Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H. Ballard Signed: Engineering Technician Date: 6/17/2004 Owner 6r OWn-e~s Designee, Title Certificate of Inservice Inspection I, the undersigned,.holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components descnlbed in this Owner's Report during the period I J v 3 to 6(4&-O , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

-TOMAJ Al~rL4 P L WCommissions: Ilt5 r3/, ,9t)//7/ A4/1/

U'J I A 7 5 A 7 //,

Insneetor's Sianature National Board, State, and Endorsements Date: 6 - Go 2r0O

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl

1. Owner: Calvert Cliffs Nuclear Power Plant, Inc. Date: 6/17/2004 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet I of 2 (address)
2. Plant: Calvert Cliffs Nuclear Power Plant Unit: One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-024c, MWO No. 1200205334 (address) (P.O. no., job no., etc.)
3. Work Performed by: Calvert Cliffs Nuclear Power Plant Dept. Type Code Symbol Stamp: N/A (name) Authorization No.: N/A Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class: One (address)
4. Identification of System: System Number 064 SystemName: Reactor Coolant System 5.(a) Applicable Construction Code andClass: ASME B31.7 1969 Edition, Sum. 1971 Add; Class I (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition -
6. Identification of Components Repaired or Replaced and Replacement Components: ASME Repaired, Code Name of Name of Manufacturers National Other Year Replaced, oi Stamped Componet Manufacturer Serial Number Board No. Identification Built Replacemen (Yes or No)

Pipe Support Bechtel 2 1/2"CC-10-1002- N/A #11 Pressurizer Pipe Support to 1- 1975 Repalred/Repl No R12 MOV.405 aced Steel Plate DuBose National 89317-GX Ht.#: N/A Plate, Steel 1 1/2 In. X 48 In. X 96 1993 Replacement No Energy Services 421J4411 InASME SA-36 Inc.

Nut Consolidated 405854 Ht.# 7307732 N/A Nut, Heavy Hex, 5/8 In. X 11 TPI, 2001 Replacement No Power Supply ASME SA-194 Gr. 2H Rod Mackson Inc. 412170 Ht.#: 622817 N/A Rod, Allthread, 5/8 In. XIITPI, 2004 Replacement No ASME SA-193 Gr. B7

7. Description of Work:

This plan was for the pipe support work on 2 1/2"CCI0-1002-R12 in support of the replacement of 1-MOV-405, #11 Pressurizer Isolation Block Valve for 1-ERV-404.

8. Tests Conducted: Hydrostatic:[] PneumaticO2 Nominal Operating Pressure: Inservice: f Leakage: E Functional: E Pressure: NIA psi. Test Temperature: N/A Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) information in Items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

ci"qe i.Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section Xi VT-3 Visual Examination of the affected component support was performed prior to the system being returned to service.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Repalr/Reolacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H.Ballard Signed: Engineering Technician Date: 6/17/2004 Owner Kr ~v Deit-d, rifle Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described inthisOwner'sReportduringtheperiod '1-/7- ' to 6 - .and state to the best of my knowledge and belief, the Owner has performed examinations and.taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

bOsJLie-d) 4 . 5* -i /7Z't ,w.,

a'0 aTO1J-iJ A)OWt/2 Ld ;41- S 7 4 f Commissions: V n 7r 3 1 , l) /7/, at/

I Al N oard,9 Sae-,aEosens t/ v nsnectnrss Signature National Board, State, and Endorsements Date: v I ----- 20---

FORM NIS-2 OWNER'S REPORT 1OR REPAIR / REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl Owner:

O. Calvert Cliffs Nuclear Power Plant, Inc. Date: 6116/2004 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet I of 2 (address)

2. Plant: Calvert Cliffs Nuclear Power Plant Unit: One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-018, MWO No. 1200301717 (address) (P.O. no., job no., etc.)
3. Work Performed by: Calvert Cliffs Nuclear Power Plant Dept. Type Code Symbol Stamp: N/A (name) Authonzation No.: N/A Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class: One (address)
4. Identification of System: System Number 064 System Name: Reactor Coolant System 5.(a) Applicable Construction Code and Class: ASME B&PV Code Sect. 111,1983 Edition, Sum.1983 Add; Class 1 (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition
6. Identification of Components Repaired or Replaced and Replacement Components: ASME Repaired, Code Name of Name of Manufacturers National Other Year Replaced, oi Stamped Componet Manufacturer Serial Number Board No. Identification Built Replacemen (Yes or No)

RCP Seal Sulzer Blngham SN: 1C864 NB 1236 #1IB Reactor Coolant Pump 1988 Repalred/Repi Yes Inc. Mechanical Seal. aced Seal BGE CCNPP Shops 1200103259 SN: NB: 1238 Seal, Cartridge Assembly (RCP) 2002 Replacement Yes IC866 875B-3V Complete Sulzer Blngham per FCR 87-0074

7. Description of Work:

This plan was for the replacement of the mechanical seal on #11 B Reactor Coolant Pump.

8. Tests Conducted: Hydrostatic:FJ Pneumaticf Nominal Operating Pressure: Inservice: [ Leakage: W Functional: E Pressure: 2260 psi. Test Temperature: 532 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) information in Items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section Xi System Leakage Test of the affected component was performed during the system conditions listed in section 8. of this report.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this RevalrlReolacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H. Ballard Signed: Engineering Technician Date: 6/16/2004 er or Owner's Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period 3 3 to 0Y ., and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

00AL47- d .S9470N =2 AN.

OLt Commissions: iJfS , SDA3 117/ enI/

- - e l Sav7 Nationa77BaM St and EJnre

, Inspector's Signature National Board, State, and Endorsemnents Date: i L s7 0- -

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xl

1. Owner: Calvert Cliffs Nuclear Power Plant, Inc. Date: 4/1912004 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet I of 2 (address)
2. Plant: Calvert Cliffs Nuclear Power Plant Unit: One_

(name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-080, MWO No. 1200303202 (address) (P.O. no.,job no., etc.)

3. Work Performed by: Calvert Cliffs Nuclear Power Plant Dept. Type Code Symbol Stamp: N/A Work -_bAuthorization No.: N/A Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 _ Section XI Class: Two (address)
4. Identification of System: System Number 041 System Name: Chemical Volume Control
5. (a) Applicable Construction Code and Class: ASME 831.7 1969 Edition, Sum. 1971 Add; Class 2 (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition
6. Identification of Components Repaired or Replaced and Replacement Components: ASME Repaired, Code Name of Name of Manufacturers National Other Year Replaced, oi Stamped Componet Manufacturer Serial Number Board No. Identification Built Replacemen (Yes or No)

Pipe Support Bechtel 1-ACC233X-SUP N/A #l1ChargingPumpDischargeDe- 1980 Repalred/Repi No Surger Restraint aced

7. Description of Work:

This plan was for the work on the support/restraint around #11 Charging Pump Discharge De-surger. Shims were used and are not considered Section XI work, but the welding was controlled by a Section Xl WAT which was documented on the R&R.

8. Tests Conducted: Hydrostatic:[] PneumaticCl Nominal Operating Pressure: Inscrvice: E Leakage: D Functional: E Pressure: N/A psi. Test Temperature: N/A Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) information in Items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

No Section XI Pre-Service NDE was performed in support of this activity.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance _______

We certify that the statements made in thUs report are correct and that this RepairlReplacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H. Ballard Signed: Engineering Technician Date: 4/19/2004 Owner or Owner's Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period 12 -/0 - 0 3 to 2 - . 3- o * , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

9 ,- Commissions: l S-3 A( A Ap Q n i v- ,

,Insnecrns Sirnature National Board, State, and Endorsements Date: -4'K-.23 r 7--

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xi

1. Owner: Calvert Cliffs Nuclear Power Plant, Inc. Date: 6/1512004 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet I of 2 (address)
2. Plant: Calvert Cliffs Nuclear Power Plant _ Unit: One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-072, MWO No. 1200303410 (address) (P.O. no., job no., etc.)
3. Work Performed by: Calvert Cliffs Nuclear Power Plant Dept. Type Code Symbol Stamnp: N/A (name) Authorization No.: N/A Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class: One (address)
4. Identification of System: System Number 052 System Name: Safety Injection 5.(a)ApplicableConstructionCodeandClass: ASME B31.1.0 1967 Edition, CCases N-2, N-10 (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition
6. Identification of Components Repaired or Replaced and Replacement Components: ASME Repaired, Code Name of Name of Manufacturers National Other Year Replaced, oi Starped Componet Manufacturer Serial Number Board No. Identification Built Replacemen (Yes or No)

Valve ITT Hammel-Dahl 694126-006 N/A #12B Safety Injection Tank, 1974 Repafred/Repi No Reactor Safeguards Check Valve aced leakage drain CV to R.W.T.

Plug Assembly Flowserve 400322 Ht.#: 726176 N/A Plug & Stem Ass. I In. 1500 lb. 2000 Replacement No Corporation ITT Hammel-Dahl Unbalanced Globe Valve, BGEDRWG 12121-0013, Item #6

7. Description of Work:

This plan was for the rebuilding of the #12B Safety Injection Tank, Reactor Safeguards Check Valve leakage drain 1-CV-648 to R.W.T.

8. Tests Conducted: Hydrostatic:[ Pneumaticd Nominal Operating Pressure: Inservice: E Leakage: E Functional: M Pressure: N/A psi. Test Temperature: NIA Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet2of 2 FORM NIS-2 (Back)

9. Remarks:

No Section Xi Pre-Service NDE was performed in support of this activity.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this RevalrlReplacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H.Ballard Signed: Engineering Technician Date: 6/15/2004 Own5er of Owner's Designee, Title-Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period 10 -a7-0 3 to 3-9 v and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

DEEDj A. SJt41 rL*r M9z Z3y add4me-s -i r-m an - a=, -) Commissions: AJ8 ' 93 / , Ato //7 / A-i//f AJ /77 IA/ 4f/S.

6: - 4, Inspector's Signature National Board, State, and Endorsements Date: l 6 200 M -

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xl

1. Owner: Calvert Cliffs Nuclear Power Plant, Inc. Date: 2/1912004 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet 1 of 2 (address)
2. Plant: Calvert Cliffs Nuclear Power Plant ___ Unit: One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2003-1-075, MWO No. 1200303794 (address) (P.O. no., job no., etc.)

Type Code Symbol Stamp: N/A

3. Work Performed by: Calvert Cliffs Nuclear Power Plant Dept. Authorization No.: N/A (name)

Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class: Two (address)

4. Identification of System: System Number 041 System Name: Chemical Volume Control 5.(a) Applicable Construction Code and Class: ASME B31.7 1969 Edition, Sum. 1971 Add; Class 2 (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition
6. Identification of Components Repaired or Replaced and Replacement Components: ASME Repaired, Code Name of Name of Manufacturers National Other Year Replaced, oi Stamped Componet Manufacturer Serial Number Board No. Identification Built Replacemen (Yes or No)

Pipe Support Bechtel IACC233Z, SUP N/A #13 Charging Pump Discharge De- 1980 Repaired/Repl No

! . . I

. I  : .. .

Surger Restraint aced Steel Plate DuBose National 400428 Ht#Y07703 N/A Plate, Steel I/2 In. X 48 In. X 96 2001 Replacement No Energy Services or A351S In., ASME SA-36 Inc.

7. Description of Work:

This plan was for the work on the support/restraint around #13 Charging Pump Discharge De-surger that was allowed by ES200300606-000.

8. Tests Conducted: Hydrostatic:M Pneumaticd Nominal Operating Pressure: Inservice: O Leakage:E Functional: a Pressure: N/A psi. Test Temperature: N/A Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x I I in., (2) information in Items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

No Section XI Pre-Service NDE was performed in support of this activity.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Repair/Replacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H.Ballard Signed: Owo__Tln e Technician Date: 2/19/2004 Owner or Own s Designee, itl Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period _3 to /g -. 27 - o 3 , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

~  % 9 Conmnissions: WRT 41tn 17/,

A3 AzT.Aga7L Insnectores Sinature National Board, State, and Endorsements Date: 3-O-

  • 20

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xl

1. Owner: Calvert Cliffs Nuclear Power Plant, Inc. Date: 4/20/2004 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet I of 2 (address)
2. Plant: Calvert Cliffs Nuclear Power Plant Unit: One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 - R&R No. 2003-1-081, MWO No. 1200304508 (address) (P.O. no., job no., etc.)

Dpt Type Code Symbol Stamp: N/A

3. Work Performed by: Calvert Cliffs Nuclear Power Plant De (name)

Authorization No.: N/A Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class: Two (address)

4. Identification of System: System Number 052 System Name: Safety InJection __ _ __

5.(a) Applicable Construction Code and Class: ASME Draft Code for Pumps & Valves, 1968 Edition, March 1970 d; Class 3 (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition

6. Identification of Components Repaired or Replaced and Replacement Components: ASME Repaired, Code Name of Name of Manufacturers National Other Year Replaced, oi Stamped Componet Manufacturer Serial Number Board No. Identification Built Replacemen (Yes or No)

Valve Velan Enginnering SN: 1314 N/A Refueling Water Tank Drain to 1975 Repaired/Rep! Yes Co. Miscellaneous Waste Storage aced Tank Isolation Valve

7. Description of Work:

This plan was for the welding on 1-HVSI-4163, Refueling Water Tank Drain to Miscellaneous Waste Storage Tank Isolation Valve. This welding is only for tacks on the bonnet assembly to prevent the Yoke Bushing/Nut from backing out.

8. Tests Conducted: Hydrostatic:Z Pneumatic: Nominal Operating Pressure: inservice: E Leakage: E Functional: E Pressure: N/A psi. Test Temperature: N/A Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) information in Items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2

. FORM NIS-2 (Back)

9. Remarks:

No Section Xi Pre-Service NDE was performed in SUDDort of this activity.

Applicable Manufacturer's Data Reports to be Attached

- Certificate of Compliance RevalrlReplacement conforms to the We certify that the statements made in this report are correct and that this rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H.Ballard Signed: AYo- Owner or Owners Designee, Title Engineering Technician Date: 4/20/2004 Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period / 2_- 1 o It - /2- /8? -0 3 , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

Commissions: A49 9U.?/ 1 4Az ',f 41 7 ,

Inspector's Sitwure National Board, State, and Endorsements Date: 5.... 200(

FORM NIS-2 OWNER'S REPORT FOR REPAIR i REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl

1. Owner: Calvert Cliffs Nuclear Power Plant, Inc. Date: 6/17/2004 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet I of 2 (address)
2. Plant: Calvert Cliffs Nuclear Power Plant Unit: One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2004-1-009a, MWO No. 1200400341 (address) (P.O. no., job no., etc.)
3. Work Performed by: Calvert Cliffs Nuclear Power Plant Dept. Type Code Symbol Stamp: N/A (name) Authorization No.: N/A Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class: Two (address)
4. Identification of System: System Number 041 System Name: Chemical Volume Control 5.(a)ApplicableConstructionCodeandClass: ASME B31.1.0 1967 Edition, 1972 Add (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition
6. Identification of Components Repaired or Replaced and Replacement Components: ASME Repaired, Code Name of Name of Manufacturers National Other Year Replaced, oi Stamped Componet Manufacturer Serial Number Board No. Identification Built Replacemen (Yes or No)

Piping System Bechtel 3"HC-7-1004 N/A #12 Boric Acid Pump discharge to 1975 Repaired/Repl No I-BS-209, basket strainer. aced Pipe Tloga Pipe Supply 76446-GX Ht.#: N/A Pipe, 3 In.Sch. 10, ASME SA-376 1993 Replacement No Co. Inc. L25610 Tp. 304 Nut Mackson Inc. 407912 Ht.#: N/A Nut, Heavy Hex, s/8 in. X 11 TPI, 2002 Replacement No 7307732 ASME SA-194 Gr. 2H Rod Mackson Inc. 409797 Ht.#: 614117 N/A Rod, Althread, 518 In. X 11 TPl, 2003 Replacement No ASME SA-1 93 Gr. B7 Slip-on Flange DuBose Natlonal 54906-GX Heat N/A Flange, 3 In., 150 lb., Raised Face, 1992 Replacement No Energy Services Code: D3912 Slip-on, ASME SA-182, Gr. F316 Inc.

7. Description of Work:

This plan was for the replacement of the 3" piping, fittings and fastener material from I -HVCVC-236 to the flange on the upstream side of basket strainer 1-BS-209.

8. Tests Conducted: Hydrostatic:M PneumaticC Nominal Operating Pressure: Inservice:E Leakage:R Functional: a Pressure: 100 psi. Test Temperature: 150 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x I1 in., (2) information in Items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 q tA I -FORM NIS-2 (Back)

9. Remarks:

A Section Xi Svstem Leakaae Test of the affected component was performed durina the system conditions listed in section 8. of this report. Code Case N-416-2 was invoked to satisfy Section XI required Pressure tests. Addtional Section III Examinations were performed (as anolicable) to satisfy Code Case N-416-2 and Rea.Guide 1.147.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this RenalrlReolacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H. Ballard Signed: Engineering Technician Date: 6/17/2004 Owner or Owner's Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period . 3 -o to 3-5 *Y , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

DoAM-u A - SH14*-P/I'L FAmt /YIZ.

o4tN 46DA6S k-7 7WCF~f Z Commissions
AJIR9 9-3J 3 Ai9 /17/ , //

_ _l _

Dt Inspector's Signture National Board, State, and Endorsements Date: 60 - / 7 200v

F6 RM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl

1. Owner: Calvert Cliffs Nuclear Power Plant, Inc. Date: 6/1712004 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet I of 2 (address)
2. Plant: Calvert Cliffs Nuclear Power Plant __ Unit: One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2004-1-009b, MWO No. 1200400341 (address) (P.O. no., job no., etc.)

Type Code Symbol Stamp: N/A

3. Work Performed by: Calvert Cliffs Nuclear Power Plant Dept. Authorization No.: N/A (name)

Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class: Two (address)

4. Identification of System: System Number 041 SystemName: Chemical Volume Control 5.(a) Applicable Construction Code and Class: ASME B31.1.0 1967 Edition, 1972 Add (b) Applicable Sect Xl Ed. for Repairs/Replacement 1998 Edition
6. Identification of Components Repaired or Replaced and Replacement Components: .ASME Repaired, Code Name of Name of Manufacturers National Other Year Replaced, oi Stamped Componet Manufacturer Serial Number Board No. Identification Built Replacemen (Yes or No)

Pipe Support Bechtel 3"HC-7.1004,H2/R3 N/A Pipe Support on CVCS Sys. 1975 Repilred/Repl No upstream of 1-BS-209, basket aced strainer.

7. Description of Work:

This plan was for the removal and rewelding of pipe support 3"HC-7-1004, H2 / R3, upstream of 1-BS-209, basket strainer.

8. Tests Conducted: Hydrostatic:E PneumaticC] Nominal Operating Pressure: Inservice: E Leakage: [] Functional: E Pressure: N/A psi. Test Temperature: N/A Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x I I in., (2) information in Items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

No Section XI Pre-Service NDE was Derformed in support of this activity, Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Reoalr/Renlacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Sta-mp: N/A Certificate ofAuthorization No.: N/A Expiration Date: N/A Charles H.Ballard Signed: Engineering Technician Date: 6/17/2004 Owner or Owfr's Deignee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid cormnission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described in this Owner's Report during the period A v / to S -/ Y e" , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XM.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection. - -

&0,4Ai-O A &8hffD ftA7 MfO> lJS Z72 Commissions: A18 3 8X3 1 /A 11//7/ .4A4J0 Insnectnr's Sianature National Board, State, and Endorsements Date:- 6- /7 --- M

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xl

1. Owner: Calvert ClIffs Nuclear Power Plant, Inc. Date: 5/20/2004 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet 1 of 2 (address)
2. Plant. Calvert Cliffs Nuclear Power Plant Unit: One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2004-1-017, MWO No. 1200401939 (address) (P.O. no., job no., etc.)

Type Code Symbol Stamp: N/A

3. Work Performed by. Calvert Cliffs Nuclear Power Plant Dept.

Authorization No.: N/A (name)

Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class: Two (address)

4. Identification of System: System Number 052 SystemName: Safety Injection 5.(a)ApplicableConstructionCodeandClass: ASME B31.7 1969 Edition, Sum. 1971 Add; Class 2 (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition
6. Identification of Components Repaired or Replaced and Replacement Components: ASME Repaired, Code Name of Name of Manufacturers National Other Year Replaced, oi Stamped Componet Manufacturer Serial Number Board No. Identification Built Replacemen (Yes or No)

Rod Eye Grin neil Pipe Support Bechtel 12" GC-9-1003-R6 N/A Sarety Injection Piping Support 1975 Repalred/Repl No aced Rod Eye Grinnell 45824 NIA Bracket, Rod Eye, Rear 1999 Replacement No Bracket Corporation Assembly, 2 1/2" size, Grinnell Fig. 201, Item 17, ASME SA-216, Gr.WCB

7. Description of Work:

This plan was for the replacement of the lower rod eye bracket on Snubber 1-52-34, on support 12"GC9-1 003-R6.

8. Tests Conducted: Hydrostatic:M Pneumaticfj Nominal Operating Pressure: Inservice: El Leakage: M Functional: E Pressure: N/A psi. Test Temperature: NIA Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Z0 d -bO1 0>/'=d4/ ACW j3 . J A 8AB PE Orf AJ1-ak oF RD p . A00f P/ot7 $et2 of 2 FORM NIS.2 (Back)

9. e,=arks:

No Sectdon Xl Pre-Service NDE was grftrned in suoyort of ths actM _

- Applicable Manufactwc's Data Repmu to be Attacbed

.~' . Certificate of Compliance  ;

We ear that tlt stamtrnade hi rLport aetrect Ad tbat this -8421108212e rdes of ibe ASO Code, SwdcronM.

Type coa Symbol Stapp: N/A Cerdficateof Autorizadon No.: NIA xpiratdon Date NIA Sipe / Charles H.3allard Signue 4MS f Date:+/-O So,20Q4 t

Certificate oflnservice Inspection 1,the undesigned, holding a valid coovuhIon isuadby dte Nadonul Board of Boiler and Ptesgure Vessel laspectors and dmc State of Mayland an employed by ABS Conmufi of oustom TX have inspected th cwrmpotenb deribed intbis Ow s Repot ing thepegiod .2-A to astateto te benof Imowledge and belief, the Own= bAs performed raminvions owd taken co ticdve =ea=u descnbed inthis Ovrs Report in accordance with the xarirea of the ASM Code Secion :L By siS this certficte neither 1e Isp!eTtr wr his enmpljdybrakes aty warant exprwed or implie4 canjceg dw examinarios and coucive maswu desenbed in this Owncs fepoit fPfwre, neirdh the Inpector nor his employer shall b liable i any mrer for any pesonal irjuy or property 4gtwga ofa lu of any kd adsig f0om o connected wih thu isspecdox g6 1.a-771 //(5 1Hv rm4 Stoand

_otiana~oa . Enaorsemants Pats: 6- - 5.Z 200j34 .. . . .

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl

1. Owner: Calvert Cliffs Nuclear Power Plant, Inc. Date: 6/21/2004 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet 1 of AL (address)
2. Plant: Calvert Cliffs Nuclear Power Plant __ Unit: Common (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. SNUB-0-004, MWO No. SNUB POOL (address) (P.O. no., job no., etc.)

Type Code Symbol Stamp: N/A

3. Work Performed by: Calvert Cliffs Nuclear Power Plant Dept. Authorization No.: N/A (name)

Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section X Class: 1, 2, & 3 (address)

4. Identification of System: System Number 065B SystemName: Seismic Snubbers 5.(a) Applicable Construction Code and Class: ASME B31.7 1969 Ed, Sum.1971 Add. Class I or Combustion Eng. Spec 8067-487-503 (b) Applicable Sect X1 Ed. for Repairs/Replacement 1998 Edition
6. Identification of Components Repaired or Replaced and Replacement Components: ASME Repaired, Code Name of Name of Manufacturers National Other Year Replaced, oi Stamped Componet Manufacturer Serial Number Board No. Identification Built Replacemen (Yes or No)

Snubber Pool Grinnell Snubber Pool N/A Hydraulic Shock and Sway 1975 RepaIred/RepI No Corporation Suppressor aced Snubber Grinnell 59013-GX SN: 32323 N/A Hydraulic Shock and Sway 1991 Replacement No Corporation Suppressor, 1 1/2 In. Bore X 5 In.

Stroke, Grinnell Fig. 200 Opt. 1 Snubber Grinnell 59013-GX SN: 32325 NIA Hydraulic Shock and Sway 1991 Replacement No Corporation Suppressor, 1 1/2 In. Bore X 5 In.

Stroke, Grinnell Fig. 200 Opt. I Snubber Anvil International 411825 SN: 35846 N/A Hydmullc Shock and Sway 2004 Replacement No Inc. Grinnell Suppressor, Size: 3 X 5 In.

Supports Stroke, Anvil Fig. 3306N Snubber Grinnell 59013-GX SN: 32321 N/A Hydraulic Shock and Sway 1991 Replacement No Corporation Suppressor, 1 1/2 In. Bore X 5 In.

Stroke, Grinnell Fig. 200 Opt. 1

7. Description of Work:

This plan was for the continued control of the Snubber Pool and documentation of new components/parts added to the Snubber Pool per Section XI 1998, IWA-4132, Items Rotated From Stock. This plan covers all Snubber work from the end of Unit #2, 2003 outage through to the end of Unit #1, 2004 outage.

8. Tests Conducted: Hydrostatic:D PneumaticC Nominal Operating Pressure: Inservice: E Leakage: a Functional: E Pressure: NIA psi. Test Temperature: N/A Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in., (2) information in Items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Qh..f a4f J FORM NIS2 (Back)

9. Remarks:

A Section Xl VT-3 Visual Examination of the affected component suDport was performed prior to the system being returned to service.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Revalr/Reptacement conforms to the rules of the ASME Code, Section X1.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: NIA

_g4 / Charles H. Ballard Signed: ,' D e, Tite Engineering Technician Date: 6/21/2004 1wnarorO%;nee Desigznee~,Titlc~-"

Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by ABS Consulting of Houston, Tx. have inspected the components described inthisOwner'sReportduringtheperiod St-;'3-D V/ to -aI -9ov ,and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XM.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Reports Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

DOD4A-O A .SH479/As'1 1-Ab .

,M IjVjA CoME7 ek)2 7 . Commissions: AJA 9A A ABASIJ 4 , lfI/f 3

- --2 I -e Z7" v /3/77 97, 0 U ss

, P Inspector's Signature National Board, State, and Endorsements Date: { -is?. 200 4"