Hearing 07/15/04 - Intervenor Exhibit B (Official Exhibit #57), Y. Yan, Et Al., Report, Post-Quench Ductility Results for Zry-4 and M5 Oxidized at 1200 Degrees C, Slow Cooled to 800 Degrees C and Quenched - Rec'D 07/15/04
ML042260354
Person / Time
Site: Catawba  Duke Energy icon.png
Issue date: 03/23/2004
From: Billone M, Burtseva T, Yan Y
- No Known Affiliation
To:
Office of Nuclear Reactor Regulation
Byrdsong A T
References
50-413-OLA, 50-414-OLA, ASLBP 03-815-03-OLA, Catawba-Intervenor-57, RAS 8320
Download: ML042260354 (3)


Text

.j -

"RA S g3,2 Post-Quench Ductility Results for Zry-4 and MS Oxidized at 1200'C, Slow Cooled to 800'C and Quenched Y. Yan, T. Burtseva and M. C. Billone March 23, 2004 DOCKETED USNRC August 9, 2004 (11:45AM)

OFFICE OF SECRETARY RULEMAKINGS AND ADJUDICATIONS STAFF UUCtER REGULATORY COMISSuON sg~-BIYL- GL4 Offichi Exh. No i 1 bidmatr of &iA,1re Staff IDENTIFIED '2I7/10WlQ Applicant RECEIVED 4_1_S_ __=

Intervenor_ REJECTED . .

Cont'g Off'r__

Contractor DATE Othur_ Witnes Repofttr /

--Te-rhP cla-l 5eiC V- C?& sec Y-0:)-

Table 1 Test Matrix for Oxidation of Samples for Post-Quench Ductility Tests. The times and ECR values listed correspond to those calculated using the Cathcart-Pawel weight gain correlation, a nominal wall thickness of 0.57 mm, and two-sided isothermal oxidation in steam. The relationship between ECR (%) and normalized weight gain (Aw in mg/cm 2 ) is ECR = 1.538 Aw for 0.57-mm-thick cladding samples.

Temperature ECR Equivalent Oxidation Time QC  % s 1000 5 210 10 841 15 1892 17 2430 20 3364 1100 5 67 10 266 15 599 17 769 20 1065 1200 5 25 10 99 15 222 17 285 20 394 1260 5 14 10 58 15 130 17 167 20 231 3

I&

Table 2 Weight Gain (Aw in mg/cm2 ) and Measured ECR (%) Values for Zry-4 and MS Oxidized in Steam at 1200'C. ECR = 1.538 Aw for Zry-4 (0.57-mm wall) and ECR =

1.437 Aw for MS (0.61-mm wall). Alloys were oxidized for the same ramp rate, approximate hold time and cooldown rate for each target ECR value.

Material Cathcart-Pawel Measured Measured ECR, % Weight Gain ECR, %

(Aw), mg/cm2 Zry-4 4.9 3.6 5.5 MS 4.6 2.8 4.0 Zry-4B 7.8 5.30 8.2 Zry-4 10.0 7.1 10.9 MS 9.1 6.3 9.1 Zry_4b 13.0 8.35 12.8 M5b 12.2 9.11 13.1 Zry4 15.7 11.1 17.1 MS 14.1 9.6 13.8 Zry-4 16.8 11.7 18.0 MS 16.0 10.9 15.7 Zry-4 20.1 13.5 20.8 MS 18.7 13.1 18.8 aAdditional test conducted to better determine ductility decrease in the range of 5 to 10% ECR.

bAdditional tests run to determine post-quench ductility at 13% CP-predicted ECR and 17% Baker-Just-predicted ECR.