June 2, 2004 Mr. Mark B. Bezilla Vice President-Nuclear, Davis-Besse FirstEnergy Nuclear Operating Company Davis-Besse Nuclear Power Station 5501 North State Route 2 Oak Harbor, OH 43449-9760
SUBJECT:
DAVIS-BESSE NUCLEAR POWER STATION, UNIT 1 - REQUEST FOR ADDITIONAL INFORMATION RELATED TO LICENSE AMENDMENT REQUEST (TAC NO. MC0366)
Dear Mr. Bezilla:
By letter dated August 11, 2003, FirstEnergy Nuclear Operating Company requested a license amendment to relocate Surveillance Requirement (SR) 4.5.2.f from the Technical Specifications to the Technical Requirements Manual. SR 4.5.2.f requires periodic performance of a vacuum leakage rate test of the watertight enclosure for valves DH-11 and DH-12.
The U.S. Nuclear Regulatory Commission (NRC) staff has found that additional information as discussed in the enclosure to this letter, is needed to complete its review of your application.
This request is from a different technical review branch than previously have requested additional information.
The NRC staff developed the enclosed question and forwarded it to your staff on May 3, 2004.
This question was discussed with your staff and it was agreed that you would provide a response 60 days from the date of this letter. If our understanding is not correct, please contact me at (301) 415-3027 at the earliest opportunity.
Sincerely,
/RA/
Jon B. Hopkins, Sr. Project Manager, Section 2 Project Directorate III Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No.: 50-346
Enclosure:
As stated cc w/encl: See next page
June 2, 2004 Mr. Mark B. Bezilla Vice President-Nuclear, Davis-Besse FirstEnergy Nuclear Operating Company Davis-Besse Nuclear Power Station 5501 North State Route 2 Oak Harbor, OH 43449-9760
SUBJECT:
DAVIS-BESSE NUCLEAR POWER STATION, UNIT 1 - REQUEST FOR ADDITIONAL INFORMATION RELATED TO LICENSE AMENDMENT REQUEST (TAC NO. MC0366)
Dear Mr. Bezilla:
By letter dated August 11, 2003, FirstEnergy Nuclear Operating Company requested a license amendment to relocate Surveillance Requirement (SR) 4.5.2.f from the Technical Specifications to the Technical Requirements Manual. SR 4.5.2.f requires periodic performance of a vacuum leakage rate test of the watertight enclosure for valves DH-11 and DH-12.
The U.S. Nuclear Regulatory Commission (NRC) staff has found that additional information as discussed in the enclosure to this letter, is needed to complete its review of your application.
This request is from a different technical review branch than previously have requested additional information.
The NRC staff developed the enclosed question and forwarded it to your staff on May 3, 2004.
This question was discussed with your staff and it was agreed that you would provide a response 60 days from the date of this letter. If our understanding is not correct, please contact me at (301) 415-3027 at the earliest opportunity.
Sincerely,
/RA/
Jon B. Hopkins, Sr. Project Manager, Section 2 Project Directorate III Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No.: 50-346
Enclosure:
As stated cc w/encl: See next page DISTRIBUTION:
PUBLIC PD3-2 R/F AMendiola JHopkins PCoates ACRS OGC JUhle SReynolds, RIII FOrr ADAMS Accession Number: ML041470234 OFFICE PDIII-2/PM PDIII-2/SC NAME JHopkins AMendiola DATE 06/02/04 06/02/04 OFFICIAL RECORD COPY
Davis-Besse Nuclear Power Station, Unit 1 cc:
Mary E. OReilly FirstEnergy Corporation 76 South Main St.
Akron, OH 44308 Manager - Regulatory Affairs FirstEnergy Nuclear Operating Company Davis-Besse Nuclear Power Station 5501 North State - Route 2 Oak Harbor, OH 43449-9760 Director, Ohio Department of Commerce Division of Industrial Compliance Bureau of Operations & Maintenance 6606 Tussing Road P.O. Box 4009 Reynoldsburg, OH 43068-9009 Regional Administrator U.S. Nuclear Regulatory Commission 801 Warrenville Road Lisle, IL 60523-4351 Michael A. Schoppman Framatome ANP 1911 N. Ft. Myer Drive Rosslyn, VA 22209 Resident Inspector U.S. Nuclear Regulatory Commission 5503 North State Route 2 Oak Harbor, OH 43449-9760 Barry Allen, Plant Manager FirstEnergy Nuclear Operating Company Davis-Besse Nuclear Power Station 5501 North State - Route 2 Oak Harbor, OH 43449-9760 Dennis Clum Radiological Assistance Section Supervisor Bureau of Radiation Protection Ohio Department of Health P.O. Box 118 Columbus, OH 43266-0118 Carol OClaire, Chief, Radiological Branch Ohio Emergency Management Agency 2855 West Dublin Granville Road Columbus, OH 43235-2206 Zack A. Clayton DERR Ohio Environmental Protection Agency P.O. Box 1049 Columbus, OH 43266-0149 State of Ohio Public Utilities Commission 180 East Broad Street Columbus, OH 43266-0573 Attorney General Office of Attorney General 30 East Broad Street Columbus, OH 43216 President, Board of County Commissioners of Ottawa County Port Clinton, OH 43252 President, Board of County Commissioners of Lucas County One Government Center, Suite 800 Toledo, OH 43604-6506 David Lochbaum, Nuclear Safety Engineer Union of Concerned Scientists 1707 H Street NW, Suite 600 Washington, DC 20006 The Honorable Dennis J. Kucinich United States House of Representatives Washington, D.C. 20515 The Honorable Dennis J. Kucinich United States House of Representatives 14400 Detroit Avenue Lakewood, OH 44107 Mr. James P. Riccio Nuclear Policy Analyst Greenpeace 702 H. Street, NW, Suite 300 Washington, DC 20001 Paul Gunter Director Nuclear Watchdog Project Nuclear Information & Resource Service 1424 16th Street NW Suite 401 Washington, DC 20009
Davis-Besse Nuclear Power Station, Unit 1 cc:
Lew W. Myers Chief Operating Officer FirstEnergy Corporation 76 South Main St.
Mail Stop A-GO-14 Akron, OH 44308
ENCLOSURE REQUEST FOR ADDITIONAL INFORMATION DAVIS-BESSE NUCLEAR POWER STATION DOCKET NO. 50-346 By letter dated August 11, 2003, FirstEnergy Nuclear Operating Company requested a license amendment to relocate Surveillance Requirement (SR) 4.5.2.f from the Technical Specifications to the Technical Requirements Manual. SR 4.5.2.f requires periodic performance of a vacuum leakage rate test of the watertight enclosure for valves DH-11 and DH-12.
The U.S. Nuclear Regulatory Commission staff has found that additional information as discussed below is needed to complete its review of your application.
1.
Associated with the proposed surveillance requirement is a change reducing the surveillance frequency. Provide additional information regarding the assessment of the change in risk of the proposed surveillance frequency change.