Text

Exel -no IC www.exeloncorp.com CoxelrnCenertionCornpai, Nuclear Quad Cities Nuclear Dovel Station 22710 2X)6 Avenue Nor-,n CoQdova, IL 61242-9740 SVP-04-041 April 26, 2004 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555 Quad Cities Nuclear Power Station, Units 1 and 2 Facility Operating License Nos. DPR-29 and DPR-30 NRC Docket Nos. 50-254 and 50-265

Subject:

Quad Cities Nuclear Power Station's Occupational Radiation Exposure Report for January through December 2003 In accordance with Technical Specifications Section 5.6.1, enclosed is Quad Cities Nuclear Power Station's Occupational Radiation Exposure Report for January through December 2003. This report is a tabulation of the number of station, utility, and contractor personnel monitored during the year (2003) receiving an annual deep dose equivalent of greater than 100 mrem, and the associated person-rem according to work and job function.

Should you have any questions concerning this letter, please contact Mr. W. J. Beck at (309) 227-2800.

Respectfully, Tothy J. Tulon te Vice President Quad Cities Nuclear Power Station

Attachment:

Quad Cities Occupational Radiation Exposure Report cc: Regional Administrator - NRC Region IlIl (w/o attachment)

REIRS Project Manager, Office of Nuclear Regulatory Research (w/ attachment)

NRC Senior Resident Inspector - Quad Cities Nuclear Power Station (w/o attachment)

Facility: QDC Page 1 of 2 Year: 2003 Occupational Radiation Exposure Report 04/22/04 12:38 PM Number of Personnel ( > 100 mrem) Quantity of Person-rem Station Utility Contractors/ Total Station Utility Contractors/ Total Employees Emplovees Others Persons Emplovees Employees Others Person-rem Reactor Operations and Surveillance Maintenance 32 3 27 62 4.198 0.762 3.071 8.031 Health Physics 25 1 4 30 4.048 0.399 1.025 5.472 Engineering 13 0 3 16 2.940 0.000 0.079 3.019 Supervisory 16 1 3 20 2.377 0.033 0.344 2.754 Operations 31 3 0 34 1.872 0.511 0.000 2.383 117 8 37 162 15.435 1.705 4.519 21.659 Routine Maintenance Maintenance 143 11 250 404 111.663 1.575 80.505 193.743 Health Physics 46 2 7 55 24.867 0.137 0.412 25.416 Engineering 22 0 17 39 6.646 0.000 2.810 9.456 Supervisory 34 1 7 42 6.891 0.012 1.344 8.247 Operations 62 2 1 65 25.149 0.035 0.246 25.430 307 16 282 605 175.216 1.759 85.317 262.292 Inservice Inspection Maintenance 26 2 53 81 1.711 0.023 2.211 3.945 Health Physics 9 0 1 10 0.155 0.000 0.010 0.165 Engineering 2 0 4 6 0.009 0.000 0.114 0.123 Supervisory 3 0 0 3 0.069 0.000 0.000 0.069 Operations 8 0 0 8 0.177 0.000 0.000 0.177 48 2 58 108 2.121 0.023 2.335 4.479 Special Maintenance Maintenance 121 5 161 287 39.601 0.392 96.825 136.818 Health Physics 30 1 5 36 3.975 0.083 0.423 4.481 Engineering 7 0 12 19 1.752 0.000 3.984 5.736 Supervisory 16 0 4 20 1.970 0.000 0.448 2.418 Operations 12 0 0 12 0.821 0.000 0.000 0.821 686 6 182 374 48.119 0.475 101.680 150.274 Waste Processing Maintenance 4 0 26 30 0.244 0.000 2.307 2.551 Health Physics 27 0 1 28 1.456 0.000 0.003 1.459 Engineering 3 0 0 3 0.020 0.000 0.000 0.020 Supervisory 7 0 1 8 0.417 0.000 0.051 0.468 Operations 47 0 1 48 2.873 0.000 1.391 4.264 88 0 29 117 5.010 0.000 3.752 8.762

Facility: QDC Page 2 of 2 Occupational Radiation Exposure Report Year: 2003 04/22/04 12:38 PM Number of Personnel ( > 100 mrem) Quantity of Person-rem Station Utility Contractors/ Total Station Utility Contractors/ Total Employees Emplovees Others Persons Emplovees Emplovees Others Person-rem Refueling Maintenance 60 9 19 88 12.879 0.834 2.424 16.137 Health Physics 16 0 0 16 1.775 0.000 0.000 1.775 Engineering 1 0 1 2 0.089 0.000 0.644 0.733 Supervisory 5 0 1 6 0.440 0.000 0.404 0.844 Operations 7 0 0 7 0.456 0.000 0.000 0.456 89 9 21 119 15.639 0.834 3.472 19.945 Total by Job Function Maintenance 143 11 268 422 170.296 3.586 187.343 361.225 Health Physics 46 3 7 56 36.276 0.619 1.873 38.768 Engineering 22 0 18 40 11.456 0.000 7.631 19.087 Supervisory 34 2 7 43 12.164 0.045 2.591 14.800 Operations 62 5 1 68 31.348 0.546 1.637 33.531 307 21 301 629 261.540 4.796 201.075 467.411