DRESDEN NUCLEAR POWER STATION UNITS 1, 2 AND 3 RADIOACTIVE EFFLUENT RELEASE REPORT January Through December 2003 DOCKET NUMBERS: 50-010/50-237/50-249 Regulatory Limits
- a.
For Noble Gases Dose Rate
- 1)
Less than 500 mrem/year to the whole body.
- 2)
Less than 3000 mrem/year to the skin.
TDo'se (Ggimmn Rndintion
- 1)
Less than or equal to 5 mrad/quarter.
- 2)
Less than or equal to 10 mrad/year.
Rein Radiation
- 1)
Less than or equal to 10 mrad/quarter.
- 2)
Less than or equal to 20 mrad/year.
b.,c.
For Iodine-131, for Iodine-133, and for all radionuclides in particulate form with half-lives greater than 8 days.
Dose Rate
- 1)
Less than 1500 mrem/year.
Dose
- 1)
Less than or equal to 7.5 mrem/quarter to any organ.
- 2)
Less than or equal to 15 mrem/year to any organ.
- d.
For Liquid
- 1)
Less than or equal to 1.5 mrem to the whole body during any calendar quarter.
- 2)
Less than or equal to 5 mrem to any organ during any calendar quarter.
- 3)
Less than or equal to 3 mrem to the whole body during any calendar year.
- 4)
Less than or equal to 10 mrem to any organ during any calendar year.
- 2.
Maximum Permissible Concentration a., b., c. For fission and activation gases, iodines and particulates with half-lives greater than 8 days, allowable dose rates are calculated by solving equations 10-1 and 10-2 from the Offsite Dose Calculation Manual.
- d.
For liquid effluents, allowable release limits are calculated by solving equations 10-3 and 10-4 from the Offsite Dose Calculation Manual.
- 3.
Average Energy The average energy of fission and activation gases was calculated for the gaseous effluents released from the site.
The average energy is based on the percentage of each fission gas nuclide present and its average energy per disintegration (E in MeV/dis) for gamma and beta emissions separately.
&GA.NINA
=
5.35E-01 MeV/dis P-EBA
=
3.86E-01 MeV/dis I
DRESDEN NUCLEAR POWER STATION UNITS 1, 2 AND 3 RADIOACTIVE EFFLUENT RELEASE REPORT January Through December 2003 DOCKET NUMBERS: 50-010/50-237/50-249
- 4.
Measurement and Approximations of Total Radioactivity
- a.
Fission and Activation Gases:
- b.
- c.
Particulates:
The Units 2/3 and Unit 1 Chimneys, Units 2/3 Reactor Building Vent and Unit I Chemical Cleaning Building effluents are continually sampled for iodines and particulates. These samples are pulled weekly and analyzed by gamma isotopic. The particulate filters are composited and sent to a vendor for gross alpha, Sr-89/90, and Fe-55 analysis. Noble gas grab samples are obtained and analyzed by gamma isotopic weekly. Tritium samples are obtained and analyzed monthly.
For the Units 2/3 Chimney and Units 2/3 Reactor Building Vent effluents, the average flow at the release points is used to calculate the Curies released. For the Unit I Chimney and Unit 1 Chemical Cleaning Building effluents, the design basis flows are used to calculate Curies released.
- d.
Liquid Effluents:
The river discharge tanks are analyzed by isotopic prior to discharge. A representative portion of this sample is saved and composited with other discharges that occur during the sampling period. The composite is sent to a vendor for analyses of gross alpha, H-3, Fe-55, and Sr-89/90 content.
The tank volumes and activities are used to calculate the diluted activity released at the discharge point from batch discharges.
- e.
Less than the lower limit of detection (<LLD)
Samples are analyzed such that the ODCM LLD requirements are met. When a nuclide is not detected then <LLD is reported.
- f.
Equipment out-of-service (1) On September 5, 2003 at 1057, continuous monitoring for Unit 2/3 Chimney Noble Gas was interrupted when the Unit 2/3 System Particulate, Iodine, and Noble Gas monitor (SPING) was out of service for approximately 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> due to a failure of the gamma background channel (channel 8). The condition was identified immediately on September 5, 2003 (Reference Dresden Station Condition Report 174515 and Work Request 110961). The monitor was returned to operable status on September 5, 2003 at 1158 when the background channel was restored during troubleshooting. Particulate and iodine samples continued to collect as required throughout the period the noble gas channel was inoperable.
- g.
Estimation of Data/Corrections:
(1) On April 30, 2003, the weekly Unit 2/3 Chimney iodine sample was analyzed using an incorrect geometry.
The iodine cartridge geometry was not available and the sample was counted using the particulate filter geometry. When the sample was reanalyzed using the proper geometry, the LLD for I-133 could not be met due to the decay of the sample. The condition was identified on May 16,2003 (Reference Dresden Condition Report 159252). The significance of the error is small. The two geometries are similar, and a comparison of long-lived nuclide activity on counts performed between the two geometries demonstrated reasonable agreement (within approximately +/-25%). The value reported from the initial count using the particulate filter geometry was used to estimate the 1-133 concentration.
2
(2) On July 23, 2003, the weekly Unit 2/3 Chimney iodine sample did not meet the I-131 LLD required by site procedures due to short sample collection time (4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />) and subsequent small sample volume. The sample Minimum Detectable Activity (MDA) for I-131 of 1.84E-12 pCi/cc was above the required LLD of 1.00E-12 ItCi/cc. The condition was identified on August 12, 2003 (Reference Dresden Condition Report 171265). The I-131 value for this sample was estimated using the concentration derived from the next iodine sample, drawn during the period of July 23 to 24. ODCM Table 12.4-1 notation (3) allows LLD's to be increased by a factor of 10 when samples are collected for short periods of time, so the requirements of the ODCM were met.
(3) On November 14, 2003, the weekly Unit 2/3 Chimney iodine sample did not meet the I-131 LLD required by site procedures due to short sample collection time (less than 11 hours1.273148e-4 days <br />0.00306 hours <br />1.818783e-5 weeks <br />4.1855e-6 months <br />) and subsequent small sample volume.
The sample MDA for I-131 of 1.4133E-12 pCi/cc was above the required LLD of 1.00E-12 ilCi/cc. The condition was identified on December 19,2003 (Reference Dresden Condition Report 192236). The I-131 concentration for this sample was estimated to be the MDA value (1.4133E-12 ptCi/cc) for the purposes of reporting. ODCM Table 12.4-1 notation (3) allows LLD's to be increased by a factor of 10 when samples are collected for short periods of time, so the requirements of the ODCM were met.
(4) On December 11, 2003 at 0300, the Unit I Chemical Cleaning Building sample pump tripped due to a loss of power to the building. The sample pump could not be restarted due to malfunction. Ventilation for the IRSF was secured. This condition was identified immediately on December 11, 2003 (Reference Dresden Condition Report 190128). It is estimated that no activity was released during the short time after the sample collection was secured and the ventilation system was shut down.
3
DRESDEN NUCLEAR POWER STATION UNITS 1, 2 AND 3 RADIOACTIVE EFFLUENT RELEASE REPORT January Through December 2003 DOCKET NUMBERS: 50-010/50-237/50-249 SUMMATION OF ALL GASEOUS RELEASES Units I1St Quarter Qunrl 3 rd Onarter 4 th Quarter Est. Total Frrnr, qn A
FTNTON k ArTTVATTON r.AqE5
- 1.
Total Release Ci 4.12E+01 6.59E+01 5.17E+01 3.82E+01 18.9%
- 2.
Average Release Rate for the Period j!Ci/sec 5.30E+00 8.38E+00 6.50E+00 4.80E+00
- 3.
Percent of Technical Specification Limit B.
- 1.
Total lodine-131 l
Ci 1.04E-03 8.43E-04 8.87E-04 2.13E-03 29.8%
- 2.
Average Release Rate of 1-131 for the Period 1tCi/sec 1.33E-04 41.07E-04 1.12E-04 2.68E-04
- 3.
Percent of Technical Specification Limit l
- 4.
Total Iodine-131. Iodine-133 and Iodine-135 Ci 5.55E-03 I 3.18E-03 3.34E-03 4.66E-03 C.
PARTICULATES
- 1.
Particulates with half-lives > 8 days Ci 1.81E-03
- 1. 1 OE-03 2.20E-03 2.68E-03 28.2%
- 2.
Average Release Rate for the Period 4ItCitsec 2.33E-04 1.40E-04 2.77E-04 3.37E-04
- 3.
Percent of Technical Specification Limit
- 4.
Gross Alpha Radioactivity Ci 1.24E-05 5.24E-06 8.30E-06
<LLD D.
- 1. Total Release 7
Ci I 2.49E+01 I 8.16E+00 [ 8.63E+00 l 4.31E+00 l 7.63%
- 2.
Averace Release Rate for the Period uCi/sec 3.21F+l00 1.04E+00 1 09+O00 5.43F-01
- 3.
Percent of Technical Specification Limit
-I I
j
- The information is contained in the Radiological Impact on Man section of the report. Total airborne release data are provided which include fission and activation gases, iodines, particulates, and tritium.
4
DRESDEN NUCLEAR POWER STATION UNITS 1, 2 AND 3 RADIOACTIVE EFFLUENT RELEASE REPORT January Through December 2003 DOCKET NUMBERS: 50-010/50-237/50-249 TABLE OF LOWER LIMITS OF DETECTABILITY FOR AIRBORNE EFFLUENTS
- 1.
FISSION/ACTIVATION GASES Kr-87 Kr-88 Xe-133 Xe-133m Xe-135 Xe-138
- 2.
IODINES 1-131 I-133
- 3.
PARTICULATES Sr-89 Sr-90 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Mo-99 Cs-134 Cs-137 Ce-141 Ce-144 gCi/ml 11.OOE-06 I.OOE-06 I.OOE-06 1.OOE-06 1.001E-06 1.OOE-06 1iCi/ml l.OOE-12 1.OOE-10 iCi/ml 1.00E-I I 1.OOE-1 1 1.OOE-I I 1.00E-I I 1.00E-1 I 1.00E-11 1.00E-I I 1.OOE-1 I 1.00E-I I 1.00E-1 I 1.OOE-I I.OOE-I 1
- 4.
OTHER H-3 Gross Alpha PLCi/m1 1.00E-06 1.00E-I I The above values are the ODCM-required LLDs. Except for the conditions noted in Section 4.g. of this report, the actual analyses always met the required LLDs.
5
DRESDEN NUCLEAR POWER STATION UNITS 1, 2 AND 3 RADIOACTIVE EFFLUENT RELEASE REPORT January Through December 2003 GASEOUS EFFLUENTS DOCKET NUMBER: 50-010 Dl MAIN CHIMNEY GROUND LEVEL RELEASES SEMI-ELEVATED RELEASES ELEVATED RELEASES xx CONTINUOUS MODE NUCLIDES RELEASED UNIT lst QTR 2n& QTR 3"d QTR 4"' QTR TOTAL FISSION GASES Ar-41 Ci Kr-85 Ci Kr-85m Ci Kr-87 Ci Kr-88_
Ci Xe-133 Ci Xe-133m Ci Xe-135 Ci Xe-135m Ci Xe-138 Ci TOTAL Ci None None None None None IODINES 1-131 Ci 1-133 Ci 1-135 Ci TOTAL Ci None None None None None PARTICULATES Fe-55 Ci Sr-89 Ci Sr-90 Ci Be-7 Ci Cr-51 Ci Mn-54 Ci 2.18E-06 3.81 F-07 6.30F,07 2.36F-06 5.55E-06 Co-57 Ci Co-58 Ci Fe-59 Ci Co-60 Ci 1.69E-06 1.67E-06 7.42E-07 4.60E-07 4.57F-06 7n-65 Ci Sr-85 Ci 7r-95 Ci Mo-99 Ci Ru-103 Ci Cd-109 Ci Az-110m Ci Sn-1 13 Ci Sb-124 Ci Sb-125 Ci Cc-134 Ci Cs-136 Ci Cc-137 Ci Ba-133 Ci 4.88E-08 4.88E-08 Ba-140 Ci Ce-141 Ci Ce-144 Ci 2.1 OF-06 2.1 OE-06 TOTAL Ci 3.87E-06 2.1OE-06 1.37E-06 4.92E-06 1.23E-05
- The activity of this nuclide is less than the LLD.
6
DRESDEN NUCLEAR POWER STATION UNITS 1, 2 AND 3 RADIOACTIVE EFFLUENT RELEASE REPORT January Through December 2003 DI MAIN CHIMNEY GASEOUS EFFLUENTS DOCKET NUMBER: 50-010 GROUND LEVEL RELEASES SEMI-ELEVATED RELEASES ELEVATED RELEASES xx BATCH MODE NUCLIDES RELEASED UNIf 1t QTR 2nd QTR 3'd QTR 4" QTR TOTAL FISSION GASES Ar-41 Ci Kr-85 Ci Kr-85m Ci K r-87 C i K r-88 C i Xe-133 Ci Xe-133m Ci Xe-135 Ci X e-I135rn C i X e-138 Ci TOTAL Ci None None None None None IODINES 1-13 1 C i 1-133 Ci 1.135 C i TOTAL Ci None None None None None PARTICULATES Fe-55 Ci Sr-89 Ci Sr-90 Ci Be-7 Ci C r-5I C i Mn-54 Ci Co-57 Ci Co-58 Ci Fe-59 Ci C o-60 C i Zn-65 Ci Sr-85 Ci 7r-95 Ci M o-99 Ci Ru-103 Ci AZ-110m Ci Sn-1 13 Ci Sb-124 Ci Sb-125 Ci Cs-] 34 Ci Cs-136 Ci Cs-137 Ci B a-133 C i Ba-140 Ci Ce-141 Ci Ce-144 Ci TOTAL Ci None None None None None
- The activity of this nuclide is less than the LLD.
7
DRESDEN NUCLEAR POWER STATION UNITS 1, 2 AND 3 RADIOACTIVE EFFLUENT RELEASE REPORT January Through December 2003 D2/3 REACrOR BUILDING VENT GASEOUS EFFLUENTS DOCKET NUMBERS: 50-237/50-249 xx GROUND LEVEL RELEASES SEMI-ELEVATED RELEASES ELEVATED RELEASES CONTINUOUS MODE NUCLIDES RELEASED UNIT l
Is QTR 2"d QTR 3 rd QTR 4th QTR TOTAL FISSION GASES Ar-41 Ci Kr-85 Ci 1.59F,04 1.59F-04 Kr-85m Ci 2.79E-01 2.79F-01 Kr-87 Ci Kr-88 Ci Xe-133 Ci 2.07E+00 2.07F+00 Xe-133m Ci Xe-135 Ci 3.43E-06 9.76F-06 1.17E-05 2.49E-05 Xe-135m Ci S
Xe-138 Ci TOTAL Ci 2.79E-01 1.69E-04 2.07E+00 2.35E+00 IODINES 1-131 Ci I.16E-05 5.59E-05 3.04E-04 3.71E-04 1-133 Ci 1.98E-06 4.07E-05 1.1 IE-04 4.39E-05 1.97E-04 1-135 Ci TOTAL Ci 1.98E-06 5.22E-05 1.67E-04 3.48E-04 5.69E-04 PARTICULATES Fe-55 Ci 1.27E-04 1.08E-04 8.33E-04 6.65E-05 I.13.E-03 Sr-89 Ci Sr-90 Ci Be-7 Ci Cr-51 Ci 2.76E-06 4.03E-05 4.31 E-05 Mn-54 Ci 6.99E-05 7.29E-05 3.34F-04 4.74E-04 9.52E-04 Co-57 Ci CO-58 Ci 1.58F-05 4.28F.-06 2.01 E-05 Fe-59 Ci 4.01 F,05 4.29E-05 8.30E-05 Co-60 Ci 7.99E-05 8.50E-05 2.12F-04 5.39F-04 9.1SE-04 7n-65 Ci 8.03E-05 2.07F-04 2.87E-04 Sr-85 Ci 7.31 E-07 7.31 F-07 Nb-95 Ci Mo-99 Ci 1.56E-05 1.56E-05 Ru-103 Ci Cd-109 Ci Ae-1 1Om Ci 9.25E-06 9.26E-06 Sn-113 Ci Sn-117m Ci Sb-124 Ci Cs-137 Ci 8.67F,07 4.OOE-06 1.54E-06 6.41 E-06 Ba-133 Ci 1.OSE-06 1.36E-05 1.46E-05 Ba-140 Ci Ce-141 Ci Ce-144 Ci Hg-203 Ci TOTAL Ci 2.96E-04 2.72E-04 1.52E-03 1.39E-03 3.48E-03
- The activity of this nuclide is less than the LLD.
8
DRESDEN NUCLEAR POWER STATION UNITS 1, 2 AND 3 RADIOACTIVE EFFLUENT RELEASE REPORT January Through December 2003 D2/3 REACTOR BUILDING VENT GASEOUS EFFLUENTS DOCKET NUMBERS: 50-237/50-249 Wy GROUND LEVEL RELEASES SEMI-ELEVATED RELEASES ELEVATED RELEASES BATCH MODE__
NUCLIDES RELEASED UNIT lIt QTR 2'd QTR 3rd QTR 4th QTR TOTAL FISSION GASES Ar-41 Ci K r-85 C i Kr-85m Ci K r-87 C i K r-88 Ci X e-1 33 Ci X e-133rn C i X e-135 C i X e-135rn Ci X e-138 C i TOTAL Ci None None None None None IODINES 1-131 C i 1-133 C i 1-135 C i TOTAL Ci None None None None None PARTICULATES Fe-55 C i Sr-89 C i Sr-90 C i Be-7 C i C r-5 1 C i M n-54 Ci C o-57 C i Co-58 Ci Fe-59 Ci Co-60 Ci 7n-65 Ci Sr-85 Ci 7r-95 Ci M o-99 Ci R u-103 Ci Ag-I IOmn Ci Sn-1 13 Ci Sb-124 Ci Sb-125 Ci C-s-1 34 Ci Cs-136 Ci Cs-137 Ci Ba-133 Ci Ba-140 Ci Cc-141 Ci I
I I
I I___
Ce-144 Ci I
I I_
TOTAL Ci I
- The activity of this nuclide is less than the LLD.
9
DRESDEN NUCLEAR POWER STATION UNITS 1, 2 AND 3 RADIOACTIVE EFFLUENT RELEASE REPORT January Through December 2003 D2/3 MAIN CHIMNEY GASEOUS EFFLUENTS DOCKET NUMBERS: 50-237/50-249 GROUND LEVEL RELEASES SEMI-ELEVATED RELEASES ELEVATED RELEASES xx CONTINUOUS MODE NUCLIDES RELEASED UNIT 1" QTR 2"" QTR 3rd QTR 41h QTR TOTAL FISSION GASES Ar-41 Ci 1.45E-01 3.1 OE-01 2.91 E-01 5.58E-01 3.92F+00 Kr-85 Ci Kr-85m Ci 9.23E-01 7.04E-01 1.36F+00 2.68E-01 3.25F.+00 Kr-87 Ci 1.42F+00 1.IBF.+00 1.09F+0O 8.50E-01 4.53F+00 Kr-88 Ci 2.03E+00 1.22F+00 1.56F+00 6.78E-01 5.50F+00 Xe-131m Ci 4.05E-02 6.71 E-02 8.90F-02 S
1.97F-01 Xe-133 Ci 1.76F+00 1.36E+01 4.51 E+00 1.32F+00 2.12E+01 Xe-133m Ci 4.25E-02 1.1SE-02 5.40E-02 Xe-135 Ci 1.75F+01 2.35E+01 2.17E+01 I.51E+OI 7.77F+01 Xe-135m Ci 3.59E+00 1.11 E+01 3.85E+00 3.76E+00 2.23E+01 Xe-138 Ci 1.35E+01 1.41 E+O1 1.46F+01 1.36E+01 5.59E+01 TOTAL Ci 4.09E+01 6.589E+01 5.17E+01 3.61 E+OI 1.95E+02 IODINES 1-131 Ci 1.04E-03 8.31 E-04 7.81 E-04 7.83E-03 4.48E-03 1-133 Ci 3.67F-03 2.03E-03 2.09E-03 1.92E-03 9.71 E-03 1-135 Ci 8.47F-04 2.64E-04 3.02E-04 5.68E-04 1.98E-03 TOTAL Ci 5.55E-03 3.13E-03 3.17E-03 4.32E-03 1.62E-02 PARTICULATES Fe-SS Ci 1.21 E-05 1.21 E-05 Be-7 Ci 1.46E-05 1.46F-05 Cr-SI Ci Mn-54 Ci 1.07E-04 9.37E-05 5.98E-05 2.50F-04
- 5. l E-04 Co-57 Ci t
Co-58 Ci 1.97E-06 1.97E-06 Fe-59 Ci Co-60 Ci 2.46F-04 1.64E-04 1.66F-04 2.01E-04 7.77E-04 Zn-65 Ci 3.36E-05 3.36E-05 Sr-85 Ci Y-88 Ci Sr-89 Ci I.71 E-04 7.01 E-05 7.32E-05 3.14E-04 Sr-90 Ci 7x-95 Ci Mo-99 Ci 6.52E-06 7.66E-06 1.42E-05 Ru-103 Ci 5
Cd-109 Ci Az-110m Ci 8.88E-05 3.54E-06 9.24E-05 Sn-113 Ci Sn-117m Ci Cs-136 Ci Cs-137 Ci 1.40E-06 1
1.40E-06 Ba-140 Ci 8.73F-04 5.14E-04 3.72E-04 3.06E-04 2.07E-03 Hc-203 Ci S
Ce-141 Ci t
Ce-144 Ci S
TOTAL Ci 1.5 I E-03 8.24E-04 6.76E-04 8.31 E-04 3.84E-03
- The activity of this nuclide is less than the LLD.
10
DRESDEN NUCLEAR POWER STATION UNITS 1, 2 AND 3 RADIOACTIVE EFFLUENT RELEASE REPORT January Through December 2003 D2/3 MAIN CHIMNEY GASEOUS EFFLUENTS DOCKET NUMBERS: 50-237/50-249 GROUND LEVEL RELEASES SEMI-ELEVATED RELEASES ELEVATED RELEASES XX BATCH MODE NUCLIDES RELEASED UNIT 1" QTR 2"d QTR 3rd QTR 4h QTR TOTAL FISSION GASES Ar-41 Ci Kr-85 Ci K r-85m Ci Kr-87 Ci Kr-88 Ci Xe-l 33 Ci Xe-133m Ci Xe-135 Ci Xe-135rn Ci X e-138 Ci TOTAL Ci None None None None None IODINES 1-131 Ci 1-133 C i 1-135 Ci TOTAL Ci None None None None None PARTICULATES Fe-55 Ci Sr-89 CiC Sr-90 Ci Be-7 Ci Cr-5i Ci Mn-54 Ci Co-57 Ci Co-58 Ci FR-59 Ci Co-60 Ci Sbn-65 Ci Sr-85 Ci 7z-95 Ci M o-99 Ci Ru-103 Ci A g-110rn Ci Sn-11 Ci Sb-124 Ci Sb-125 Ci C s-134 Ci Cs-136 Ci Cs-137 Ci Ba-133 Ci Ba-140 Ci Ce-144 Ci TOTAL Ci None None None None None
- The activity of this nuclide is less than the LLD.
- 11
DRESDEN NUCLEAR PONVER STATION UNITS 1, 2 AND 3 RADIOACTIVE EFFLUENT RELEASE REPORT January Through December 2003 CHEMICAL CLEANING BUILDING GASEOUS EFFLUENTS DOCKET NUMBERS: 50-010/50-237/50-249 WY GROUND LEVEL RELEASES SEMI-ELEVATED RELEASES ELEVATED RELEASES CONTINUOUS MODE NUCLIDES RELEASED UNIT Il QTR 2' QTR 3rd QTR 4h QTR TOTAL FISSION GASES Ar-41 Ci Kr-85 Ci Kr-85m Ci Kr-87 Ci Kr-88 Ci Xe-133 Ci Xe-133m Ci Xe-135 Ci Xe-135m Ci Xe-138 Ci TOTAL Ci None None None None None IODINES 1-131 Ci 1-133 Ci 1-135 Ci TOTAL Ci None None None None None PARTICULATES Fe-55 Ci Sr-89 Ci Sr-90 Ci Be-7 Ci Cr-51 Ci Mn-54 Ci 3.01E-06 7.65F.-07 6.77E-06 1OSE-05 Co-57 Ci Co-58 Ci 2.21E-07 2.21 E-07 Fe-59 Ci Co-60 Ci 3.OOE-06 6.35F-07 7.07E-07 2.38E-06 6.72E-06 Zn-65 Ci Sr-85 Ci Zr-95 Ci M1o-99 Ci t
Ru-103 Ci t
A-l l Om Ci Sn-113 Ci Sb-124 Ci Sh-125 Ci Cs-134 Ci Cs-136 Ci Cs-137 Ci Ba-133 Ci Ba-140 Ci Ce-141 Ci S.14E-07 5.14E-07 Ce-144 Ci TOTAL Ci 6.53E-06 1.40E-06 9.28E-07 9.I5E-06 1.80E-05
- The activity of this nuclide is less than the, LLD.
12
DRESDEN NUCLEAR POWER STATION UNITS 1, 2 AND 3 RADIOACTIVE EFFLUENT RELEASE REPORT January Through December 2003 CHEMICAL CLEANING BUILDING GASEOUS EFFLUENTS DOCKET NUMBERS: 50-010/50-237/50-249 xx GROUND LEVEL RELEASES SEMI-ELEVATED RELEASES ELEVATED RELEASES BATCH MODE NUCLIDES RELEASED UNIT l
I" QTR 2a QTR 3rd QTR 4t' QTR TOTAL FISSION GASES Ar-41 Ci Kr-85 Ci Kr-85m Ci Kr-87 Ci Kr-88 C.
Xe-133 Ci Xe-133m Ci Xe-135m Ci Xe-138 Ci TOTAL Ci None None None None None IODINES 1-131 C i 1-133 C i 1-135 Ci TOTAL Ci None None None None None PARTICULATES Fe-55 Ci Sr-89 Ci Sr-90 Ci Be-7 Ci Cr-S1 Ci
=
=
__=
M n-54 Ci Co-57 Ci Co-58 Ci Fe-59 Ci Co-60 Ci
.n-65 Ci Sr-85 Ci 7x-95 Ci Mo-99 Ci Ru-103 Ci Ae-133m Ci Sn-I 13 Ci Sb-124 Ci Sb-125 Ci Cs-134 Ci C s-136 Ci C s-137 Ci B a-133 Ci Ba-140 Ci Ce-141 Ci C e-144 C i TOTAL Ci None None None None None
- The activity of this nuclide is less than the LLD.
13
DRESDEN NUCLEAR POWER STATION UNITS 1, 2 AND 3 RADIOACTIVE EFFLUENT RELEASE REPORT January Through December 2003 DOCKET NUMBERS: 50-010/50-237/50-249 TABLE OF LOWER LIMITS OF DETECTABILITY FOR LIQUID EFFLUENTS
- 1.
FISSION/ACTIVATION GASES PCi/ml Kr-87 Kr-88 Xe-133 Xe-133m Xe-135 Xe-138 I.OOE-05 I.OOE-05 1.00E-05 I.OOE-05 1.OOE-05 1.001E-05
- 2.
- 3.
PARTICULATES pjCi/ml Fe-55 1.00E-06 Sr-89 5.00E-08 Sr-90 5.00E-08 Mn-54 5.OOE-07 Fe-59 5.00E-07 Co-58 5.00E-07 Co-60 5.OOE-07 Zn-65 5.OOE-07 Mo-99 5.00E-07 Cs-134 5.OOE-07 Cs-137 5.OOE-07 Ce-141 5.OOE-07 Ce-144 5.OOE-06
- 4.
OTHER 11Ci/ml H-3 1.00E-05 Gross Alpha 1.001E-07 The above values are the ODCM-required LLDs. Actual analyses always met the required LLDs.
14
DRESDEN NUCLEAR POWER STATION UNITS 1, 2 AND 3 RADIOACTIVE EFFLUENT RELEASE REPORT January Through December 2003 DOCKET NUMBERS: 50-010/50-237/50-249 SUMMATION OF ALL LIQUID RELEASES TIkits ISt (Quarter 2 nd 01narter 3 rd Quarter 4th Quarter Est.
Total Frrr, %
A.
FISSION & ACTIVATION PRODUCTS
- 1. Total Release (not including H-3. gases, alpha)
Ci 1.77E-03
<LLD
<LLD 1.23E-04 13.5%
- 2.
Averace Diluted Conc. During Period Ci/m 46.68E-09
<LLD
<LLD 1.16E-08
- 3.
Percent of Technical Specification Limit B.
- 1. Total Release Ci 1.40E+0 I
<LLD
<LLD l 2.02E-02 12.1 %
- 2.
Averaae Diluted Conc. During Release uCi/ml 5.28E-09
<LLD
<LLD 1.91E-06
- 3.
Percent of Technical Specification Limit J
C.
DISSOLVED AND ENTRAINED GASES
- 1. Total Release Ci
<LLD
<LLD
<LLD l
<LLD 20.3%
- 2.
Average Diluted Conc. During Period ItCi/ml
<LLD
<LLD
<LLD
<LLD
- 3.
Percent of Technical Snpecification Limit D.
GROSS ALPHA ACTIVITY
- 1.
Total Release Ci 1.82E-06
<LLD
<LLD
<LLD 5.58%
E.
VOLUME OF WASTE RELEASED Liters I 3.99E+06 4.90E+06 3.59E+06 1.06E+07 1.00%
(prior to dilution)
F.
VOLUME OF DILUTION WATER USED l
2 l
l l
DURING PERIOD L0 0
0 5.00%
- The information is contained in the Radiological Impact on Man section of the report.
15
DRESDEN NUCLEAR POWER STATION UNITS 1, 2 AND 3 RADIOACTIVE EFFLUENT RELEASE REPORT January Through December 2003 RADWASTE LIQUID EFFLUENTS DOCKET NUMBERS: 50-010/50-237/50-249
- 1. Number of Batch Releases:
5
- 2.
Total Time for Batch Releases:
1.73E+03 minutes
- 3.
Maximum Time Period for a Batch Release:
3.75E+02 minutes
- 4.
Average Time Period for a Batch Release:
3.45E+02 minutes
- 5.
Minimum Time Period for a Batch Release:
3.24E+02 minutes
- 6.
Average Stream Flow During Periods of Release of Effluent into a Flowing Stream:
1.52E+05 Ipm RATCH-4 MODF T.it I St rl-nrter
)n rj.rn,,
'Ard I]iinert~
Ath tinirtpr Tnt!,1 tLJajfl I
Vua~4l 1Lt
~ D J*&
Sta S J.
.W.
u vz*v Fe-55 Ci 8.12E-04 8.12E-04 Sr-89 Ci Sr-90 Ci 1-131 Ci**
1-132 Ci 1-133 Ci 1-134 Ci 1-135 Ci Cr-Si Ci Mn-54 Ci 2.89E-04 2.89E-04 Co-58 Ci 2.26E-05 2.26E-05 Fe-59 Ci 4.63E-05 4.63E-05 Co-60 Ci 3.54E-04 3.54E-04 Zn-65 Ci As-76 Ci Zr-95 Ci Sr-91 Ci Mo-99 Ci Tc-99m Ci Ru-103 Ci Ac-11Om Ci 1.1OE-04 1.1OE-04 Sb-124 Ci Cs-134 Ci Cs-136 Ci**
Cs-137 Ci 1.14E-04 1.1 4E-04 Cs-138 Ci Ba-140 Ci La-140 Ci*
Ce-1 41 Ci (above)
Ci 1.75E-03 None None None 1.75E-03 T o ta l H-3 Ci I1.40E+01 1______I.40E+01 Kr-87 Ci Kr-88 Ci Xe-133 Ci Xe-133m Ci Xe-135 Ci Xe-138 Ci
- The activity of this nuclide is less than the LLD.
16
DRESDEN NUCLEAR POWER STATION UNITS 1, 2 AND 3 RADIOACTIVE EFFLUENT RELEASE REPORT January Through December 2003 RADWASTE LIQUID EFFLUENTS DOCKET NUMBERS: 50-010/50-237150-249 CONTINT JOT ITS MODE TT.nt I5t r)wnirtpr Ind Ouarter rd uinrteir 4th ()uarter Totnl Fe-55 Ci Sr-89 Ci Sr-90 Ci 1-131 C i 1-132 Ci 1
1-133 Ci 1-134 Ci 1-135 Ci Cr-51 Ci Mn-54 Ci Co-58 Ci Fe-59 Ci Co-60 Ci Zn-65 Ci As-76 Ci I
Zr-95 Ci Sr-91 Ci Mo-99 Ci Tc-99m Ci Ru-103 Ci I
AR-10m Ci Sb-124 Ci Cs-134 Ci 1_
Cs-136 Ci C s-137 C i Cs-138 Ci Ba-140 Ci La-140 Ci Ce-141 Ci II (above)
Ci None None None None None T o tal H-3 Ci Kr-87 Ci Kr-88 Ci Xe-133 Ci Xe-133m Ci I
I Xe-135 Ci Xe-138 Ci
- The activity of this nuclide is less than the LLD.
17
DRESDEN NUCLEAR POWER STATION UNITS 1, 2 AND 3 RADIOACTIVE EFFLUENT RELEASE REPORT January Through December 2003 LPCI SYSTEM EFFLUENTS DOCKET NUMBERS: 50-237/50-249
- 1. Number of Batch Releases:
126
- 2. Total Time for Batch Releases:
1.56E+02 minutes
- 3. Maximum Time Period for a Batch Release:
1.24E+00 minutes
- 4.
Average Time Period for a Batch Release:
1.24E+00 minutes
- 5.
Minimum Time Period for a Batch Release:
1.24E+00 minutes
- 6.
Average Stream Flow During Periods of Release of Effluent into a Flowing Stream:
9.46E+04 1pm BATC-14 MODE Unit I" Ouarter 2d Ouarter 3td Ouarter 4th Ouarter Total Fe-55 Ci Sr-89 Ci Sr-90 Ci 1-131 Ci 1-132 Ci 1-133 Ci 1-134 Ci 1-135 Ci Cr-51 Ci Mn-54 Ci Co-58 Ci Fe-59 Ci Co-60 Ci 3.71 E-06 3.71 E-06 Zn-65 Ci As-76 Ci Zr-95 Ci Sr-91 Ci Mo-99 Ci Tc-99m Ci Ru-103 Ci Ac!-1Om Ci Sb-124 Ci Cs-134 Ci Cs-136 Ci Cs-137 Ci 1.21 E-05 1.21 E-05 Cs-138 Ci
= _
Ba-140 Ci La-140 Ci Ce-141 Ci Np-239 Ci (above)
Ci 1.21E-05 3.71E-06 1.58E-05 Total H-3 Ci Kr-87 Ci Kr-88 Ci Xe-133 Ci Xe-135 Ci Xe-138 Ci
- The activity of this nuclide is less than the LLD.
18
DRESDEN NUCLEAR POWER STATION UNITS 1, 2 AND 3 RADIOACTIVE EFFLUENT RELEASE REPORT January Through December 2003 DOCKET NUMBERS: 50-237/50-249 LPCI SYSTEM EFFLUENTS CO"NI TOT TS MODF TUnit 1'" Ouarter 2nd Ouarter 3Id Ouarter 4th Ouarter Total Fe-55 Ci Sr-89 Ci Sr-90 Ci 1-131 C i 1-132 Ci 1-133 Ci 1-134 Ci 1-135 Ci Cr-51 Ci M n-54 I
Ci Co-584 Ci Fe-59 Ci Co-60 Ci Zn-65 Ci As-76 Ci Zr-95 Ci Sr-91 Ci Mo-99 Ci Tc-99m Ci Ru-103 Ci AR-lOrm Ci Sb-124 Ci
=
==
Cs-134 Ci Cs-136 Ci I
Cs-137 Ci Cs-138 Ci Ba-140 Ci La-140 Ci Ce-141 Ci Np-239 Ci (above)
Ci None None None None None T o ta l_
H-3 Ci Kr-87 Ci Kr-887 Ci Xe-133 Ci Xe-135 Ci I
I X e-138 C i I
I_
I__
I__
I__
- The activity of this nuclide is less than the LLD.
19
DRESDEN NUCLEAR POWER STATION UNITS 1, 2 AND 3 RADIOACTIVE EFFLUENT RELEASE REPORT January Through December 2003 DOCKET NUMBERS: 50-010/50-237/50-249 UNITS 1, 2 & 3 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS A.
SOLID WASTE SHIPPED OFFSITE FOR BURIAL OR DISPOSAL (NOT IRRADIATED FUEL)
- 1.
Type of Waste Unit 12-month Est. Total Error, %
period
- a.
Spent resins, filter sludges, evaporator bottoms, etc.
m3 1.26E+02 2
Ci 1.36E+03 5%
- b.
Dry compressible waste, contaminated equipment, etc.
m3 1.25E+03 Ci 1.03E+01 25%
- c.
Irradiated components, control rods, etc.
m3 3.27E+00 Ci 4.14E+04 25%
- d.
Other (describe) - Contaminated Oil m3 3.62E+01 25%
Ci I1.40E-0625
- 2.
Estimate of Major Nuclide Composition (by type of waste)
- a.
Spent resins, filter sludges, evaporator bottoms, etc.
Perrent CE Aries Fe-55 Co-60 Cs-137 Mn-54 Ni-63 Zn-65 67.5 16.9 6.6 5.3 1.4 1.1 9.19E+02 2.30E+02 8.96E+01 7.22E+01 1.93E+01 1.53E+01
- b.
Dry compressible waste, contaminated equipment, etc.
Perrent %
(Cries Fe-55 Co-60 Cs-137 Ni-63 Mn-54 40.9 21.6 20.4 12.6 3.5 4.21E+00 2.22E+00 2.10E+00 1.30E+00 3.65E-01
- c.
Irradiated components, control rods, etc.
Peraent %
Co-60 Fe-55 Ta-182 Ni-63 Mn-54 51.8 39.0 4.6 2.6 1.6 irieps 2.14E+04 1.62E+04 1.92E+03 1.06E+03 6.78E+02 20
DRESDEN NUCLEAR POWER STATION UNITS 1, 2 AND 3 RADIOACTIVE EFFLUENT RELEASE REPORT January Through December 2003 DOCKET NUMBERS: 50-010/50-237/50-249 UNIT 1, 2 & 3 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS (Cont.)
- 2.
Estimate of Major Nuclide Composition (by type of waste) - Continued
- d.
Other - Contaminated Oil Percent 9n Fe-55 Co-60 Ni-63 Cs-137 Mn-54 43.4 25.9 16.9 8.4 4.8 CDmies 6.08E-07 3.63E-07 2.37E-07 1.18E-07 6.67E-08
- 3.
Solid Waste Description NTTMBFR OF ST-TIPMFNTS 28 11 10 3
1 MnDE OF TR ANSPORTATTQN Motor Freight (exclusive use only)
Motor Freight (exclusive use only)
Motor Freight (exclusive use only)
Motor Freight (exclusive use only)
Motor Freight (exclusive use only)
DESTTNATTON GTS Duratek, Oak Ridge, TN CNS, Barnwell, SC Envirocare, Clive Ur Alaron, Wampum, PA GTS Duratek, Kingston, TN B.
IRRADIATED FUEL SHIPMENTS (Disposition)
NUTMRFR OF SHTTPMFNTS None MODE OF TRANSPORTATION DESTINATIN 21
DRESDEN NUCLEAR POWER STATION UNITS 1,2 AND 3 RADIOACTIVE EFFLUENT RELEASE REPORT January Through December 2003 DOCKET NUMBER: 50-010/50-237/50-249 ABNORMAL RELEASES*
A. LIQUID
- 1.
Number of Releases:
n
- 2.
Total Activity Releases:
B. GASEOUS
- 1.
Number of Releases:
- 2.
Total Activity Releases:
A AAF+nn C, A
0 nnF+0Ci No abnormal releases occurred during 2003.
- These releases are included in the Effluents Summation of all Releases Tables and in the Radiological Impact on Man.
22
DRESDEN NUCLEAR POWER STATION UNITS 1, 2 AND 3 RADIOACTIVE EFFLUENT RELEASE REPORT January Through December 2003 DOCKET NUMBER: 50-010/50-237/50-249 UNMONITORED RELEASES*
A. LIQUID
- 1.
Number of Releases:
9
- 2.
Total Activity Releases:
2 03F-fl? Ci B. GASEOUS
- 1.
Number of Releases:
4
- 2.
Total Activity Releases:
7 16 F-)4 (hi A. I Water in on-site storm sewers are routinely sampled and analyzed for tritium content. The highest storm drain concentration measured during 2003, 1016 pCiA, was used for all of 2003. The total activity released is based on an estimated typical discharge flow of 10 gallons per minute. An estimated 2.02E-02 Ci of H-3 may have been released into the environment.
Various storm sewer locations on-site are periodically analyzed for Tritium.
A.2.
Grab samples of the Wastewater Treatment System effluent are routinely collected and analyzed for radioactivity. Gamma spectroscopy analysis identified Mn-54 on several samples taken in December 2003. A total of l.I9E-04 Ci is estimated to have been released via this pathway.
B.l The Unit I Main Turbine Floor (MTF) is used as an area to work on contaminated equipment. The ventilation, which exhausts through the Unit I Main Chimney, is no longer operational and the floor is at ambient pressure with the outside environment. With radiological work activities being performed on the MTF, the potential exists for airborne activity to be released to the environment through various potential release points. The estimated release through these points is 3.6E-05 Ci per year of Cs-137.
B.2 The Chemistry Hotlab ventilation exhausts directly into the environment without any monitoring. The calculated release to the environment is 5.99E-04 Ci of noble gases and 4.12E-05 Ci of iodines/particulates.
B.3 The Unit 2/3 heating steam system has low-level contamination present. During operation of the system, some steam is vented directly into the environment. A total activity of 1.91E-06 Ci is estimated to have been released to the environment from this system during 2003.
B.4 Past radiological surveys have identified low-level contamination in the East Turbine Building Ventilation ductwork. This system vents directly to the environment, therefore, a postulated release is calculated. A total activity of 3.77E-05 Ci is estimated to have been released to the environment from this system during 2003.
- These releases are included in the Effluents Summation of all Releases Tables and in the Radiological Impact on Man.
23
DRESDEN NUCLEAR POWER STATION UNITS 1, 2 AND 3 RADIOACTIVE EFFLUENT RELEASE REPORT January Through December 2003 DOCKET NUMBER: 50-010 RADIOLOGICAL IMPACT ON MAN*
UNIT I
- 1.
Airborne Releases
?A4
- n. gin T'l-n-frnn A ;A--r...,. V.1l-
.1 Quarterly Ohi.
1 SQTR 2nd QTR 3rd QTR Yearly Obj.
Annual Dose 4QTR Gamma Air 5.0 mrad 0.OOE+00 (e) 0.OOE+00 (e)
O.OOE+00 (e) 0.OOE+00 (e) 10.0 mrad 0.OOE+00 (e)
(m rad)__
Beta Air 1 0.0 mrad O.OOE+00 (e)
O.OOE+00 (e) 0.OOE+00 (e) 0.OOE+00 (e) 20.0 mrad 0.OOE+00 (e)
(m rad)
Total Body 2.5 mrem 0.OOE+00 (e) 0.OOE+00 (e) 0.OOE+00 (e) 0.OOE+00 (e) 5.0 mrem O.OOE+00 (e)
(mrem)
Skin 7.5 mrem 0.OOE+00 (e)
O.OOE+00 (e) 0.OOE+00 (e) 0.OOE+00 (e) 15.0 mrem 0.OOE+00 (e)
Organ 7.5 mrem 1.95E-05 (c) 5.03E-06 (t,a) 4.43E-06 (a) 7.95E-4 (i,c) 15.0 mrem 8.17E-04 (c)
Critical Organ Lung GI_LLI GILLI Liver ()
Liver
~Bone (c)Lie Liquid Releases Maximum Doses from Anuatic Effluents Quarterly I St QTR 2 nd QTR 3r QTR 4t QTR Yearly Obj.
Annual Dose O b i.
Total Body 1.5 mrem None None None None 3.0 mrem None (mrem) 5.0 mrem None None NoeNne 1.__rm Nn Omrgan 5.0 mrem None None None None 10.0 mr-er None 2.
Critical Organ None None None None None
- The doses reported include abnormal releases. These doses are the highest among the four analyzed receptors as described in parentheses [(i)=infant, (c)=child, (t)=teenager, (a)=adult, (e)=every receptor has the same value].
24
DRESDEN NUCLEAR POWER STATION UNITS 1, 2 AND 3 RADIOACTIVE EFFLUENT RELEASE REPORT January Through December 2003 DOCKET NUMBER: 50-237 RADIOLOGICAL IMPACT ON MAN*
UNIT 2
- 1.
Airborne Releases Maximum Doses from Airborne Releases Quarterly Ohi 1 St QTR 2n QTR 3' QTR 4th QTR Yearly Obj.
Annual Dose Gamma Air 5.0 mrad 1.80E-04 (e) 2.33E-04 (e) 3.07E-04 (e)
I.IOE-04 (e) 10.0 mrad 8.30E-04 (e)
(m rad)__
Beta Air 10.0 mrad 1.46E-05 (e) 1.91E-05 (e) 2.12E-05 (e) 1.60E-05 (e) 20.0 mrad 6.88E-05 (e)
(m rad )__
Total Body 2.5 mrem 1.69E-04 (e) 1.76E-04 (e) 2.31E-04 (e) 8.26E-05 (e) 5.0 mrem 6.26E-04 (e)
(Smrnem) 7.5 mrem 1.52E-04 (e) 1.95E-04 (e) 2.54E-04 (e) 9.38E-05 (e) 15.0 mrem 6.95E-04 (e)
Organ 7.5 mrem 3.71E-04 (c) 3.03E-03 (c) 4.14E-03 (c) 3.31E-03 (c) 15.0 mrem 1.09E-02 (c)
(rnre r )
I__
I__
Critical Organ Lung Thyroid Thyroid Thyroid Thyroid Liquid Releases Maximum Doses from Anuatic Effluents Quarterly I1" QTR 2nd QTR 3' QTR 4 th QTR Yearly Obj.
Annual Dose O b i.
Total Body 1.5 mrem 5.58E-05 (a)
O.OOE+O0 (e)
O.OOE+O0 (e) 3.86E-09 (c) 3.0 mrem 5.58E-05 (a)
(Omrgeam) 5.0 mrem 7.71E-05 (c)
O.OOE+00 (e)
O.OOE+O0 (e) 2.30E-08 (a) 10.0 mrem 7.71E-05 (c) 2.
Critical Organ Liver None None GILLI Liver The doses reported include abnormal releases. These doses are the highest among the four analyzed receptors as described in parentheses [(i)=infant, (c)=child, (t)=teenager, (a)=adult, (e)=every receptor has the same value].
25
DRESDEN NUCLEAR POWER STATION UNITS 1, 2 AND 3 RADIOACTIVE EFFLUENT RELEASE REPORT January Through December 2003 DocKEr NUMBER: 50-249 RADIOLOGICAL IMPACT ON MAN*
UNIT 3
- 1.
Airborne Releases Maximum Doses from Airborne Releases Quarterly OhM I" QTR 2nd QTR 3rd QTR 4th QTR Yearly Obj.
Annual Dose Gamma Air 5.0 mrad 4.94E-04 (e) 5.27E-04 (e) 4.81E-04 (e) 4.79E-04 (e) 10.0 mrad 1.98E-03 (ej Beta Air 10.0 mrad 4.41E-05 (e) 4.76E-05 (e) 4.23E-05 (e) 5.95E-05 (e) 20.0 mrad 1.89E-04 (e)
Total Body 2.5 mrem 3.72E-04 (e) 3.97E-04 (e) 3.63E-04 (e) 3.61E-04 (e) 5.0 mrem 1.49E-03 (e)
(rnrernL)__
Skin 7.5 mrem 4.19E-04 (e) 4.44E-04 (e) 4.06E-04 (e) 4.08E-04 (e) 15.0 mrem 1.68E-03 (e)
Organ (mrem) 7.5 mrem 2.16E-03 (c) 7.12E-03 (c) 9.05E-03 (c) 4.75E-03 (c) 15.0 mrem 2.311E-02 (c)
Critical Organ Thyroid Thyroid Thyroid Thyroid Thyroid Liquid Releases Maximum Doses from Aquatic Effluents l
Quarterly l It QTR 2 nd QTR 3r QTR 4 th QTR Yearly Obj.
Annual Dose O b i.
Total Body 1.5 mrem 5.19E-05 (a)
O.OOE+00 (e)
O.OOE+00 (e) 2.36E-07 (c) 3.0 mrem 5.21E-05 (a)
Organ 5.0 mrem 7.14E-05 (c)
O.OOE+00 (e)
O.OOE+00 (e) 1.65E-06 (a) 10.0 mrem 7.20E-05 (c) mre) 2.
Critical Organ Liver None None Liver Liver
- The doses reported include abnormal releases. These doses are the highest among the four analyzed receptors as described in parentheses [(i)=infant, (c)=child, (t)=teenager, (a)=adult, (e)=every receptor has the same value].
26
DRESDEN NUCLEAR POWER STATION UNITS 1, 2 AND 3 RADIOACTIVE EFFLUENT RELEASE REPORT January Through December 2003 DOCKET NUMBER: 50-010/50-237/50-249 METEOROLOGICAL DATA The remaining pages of this report contain the Dresden Station meteorological site quarterly joint-frequency wind rose tables for 2003.
27
Dresden Nuclear Station 35 ft. Wind Speed and Direction January-March.
2003 15OFt-35Ft Delta-T (F)
Number of Observations -
2154 Values are Percent Occurrence SPEED
...----------------- WIND DIRECTION CLASSES
STABILITY CLASSES ----------
wNWA NR NNX TOTAL EU HU SU N
NNE NE ENE E
SSW SW WSW W EU MU C SU A N L SS m PS ES 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 EU KU 1 SU N
3 SS MS ES 0.00 0.00 0.00 0.14 0.05 0.05 0.05 0.00 0.00 0.00 0.05 0.23 0.09 0.00 0.00 0.00 0.00 0.05 0.23 0.00 0.00 0.00 0.00 0.00 0.00 0.32 0.05 0.00 0.00 0.00 0.00 0.05 0.23 0.05 0.05 0.00 0.00 0.00 0.00 0.42 0.09 0.09 0.00 0.00 0.00 0.00 0.28 0.09 0.00 0.00 0.00 0.00 0.09 0.32 0.05 0.09 0.00 0.00 0.00 0.09 0.05 0.19 0.00 0.00 0.00 0.00 0.09 0.19 0.23 0.09 0.00 0.00 0.00 0.09 0.19 0.09 0.09 0.00 0.00 0.00 0.09 0.28 0.23 0.00 0.00 0.00 0.00 0.28 0.42 0.14 0.14 0.00 0.00 0.00 0.19 0.46 0.14 0.05 0.00 0.00 0.00 0.28 0.51 0.14 0.00 0.00 0.00 0.00 0.23 0.42 0.05 0.05 0.00 0.00 0.00 0.00 1.72 4.60 1.67 0.70 0.00 0.00 1.72 4.60 1.67 0.70 8.68 EU MU 4 SU N
1 SS 8MS ES 0.05 0.00 0.09 1.02 0.70 0.00 0.00 0.09 0.09 0.00 0.88 0.42 0.00 0.00 0.00 0.00 0.00 0.51 0.00 0.00 0.00 0.00 0.05 0.00 0.79 0.56 0.00 0.00 0.09 0.09 0.05 0.88 0.14 0.00 0.00 0.00 0.00 0.00 0.51 0.05 0.00 0.00 0.09 0.00 0.09 0.60 0.51 0.05 0.00 0.37 0.05 0.00 1.86 0.70 0.00 0.00 0.05 0.00 0.09 1.30 0.42 0.00 0.00 0.00 0.05 0.09 0.56 0.56 0.05 0.00 0.00 0.00 0.00 0.70 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.19 1.35 0.37 0.05 0.00 0.00 0.00 0.97 0.32 0.00 0.00 0.00 0.00 0.00 0.00 0.14 0.00 0.00 0.00 0.00 0.00 0.56 0.88 0.28 0.09 0.00 0.05 0.00 0.19 0.74 0.00 0.00 0.00 0.00 0.00 0.09 0.00 0.00 0.00 0.00 0.00 0.05 0.37 0.23 0.60 0.00 0.00 0.05 0.05 0.23 0.32 0.00 0.00 0.00 0.00 0.00 0.14 0.14 0.00 0.00 0.00 0.00 0.00 0.51 1.30 0.84 0.05 0.00 0.00 0.00 0.74 0.65 0.00 0.00 0.00 0.00 0.05 0.46 0.56 0.00 0.00 0.00 0.00 0.00 0.51 1.44 0.51 0.05 0.00 0.05 0.05 1.76 1.39 0.05 0.00 0.00 0.00 0.05 0.42 0.97 0.00 0.00 0.00 0.00 0.00 0.37 0.84 0.93 0.14 0.05 0.09 0.05 1.21 0.97 0.05 0.00 0.00 0.19 0.19 0.51 0.46 0.00 0.00 0.00 0.00 0.09 0.42 0.79 0.28 0.14 0.00 0.09 0.14 0.84 0.79 0.19 0.00 0.14 0.05 0.23 1.30 0.42 0.00 0.00 0.00 0.05 0.05 0.46 0.51 0.28 0.05 0.00 0.09 0.19 0.51 0.70 0.00 0.00 0.19 0.00 0.19 0.70 0.19 0.00 0.00 0.00 0.05 0.00 0.88 1.76 0.23 0.00 0.19 0.05 0.19 1.16 3.34 0.05 0.00 0.42 0.09 0.05 0.56 0.42 0.00 0.00 0.05 0.00 0.05 1.07 2.37 0.23 0.00 0.37 0.28 0.23 1.25 2.65 0.00 0.00 0.70 0.09 0.42 1.21 0.60
'0.00 0.00 0.05 0.09 0.19 1.35 2.14 0.19 0.05 0.65 0.46 0.19 1.21 2.09 0.00 0.00 0.14 0.00 0.05 0.05 0.05 0.00 0.00 0.28 0.09 0.05 1.21 1.53 0.05 0.00 0.19 0.05 0.19 2.23 1.95 0.00 0.00 0.00 0.05 0.09 0.42 0.05 0.00 0.00 0.51 0.51 0.37 0.74 10.86 17.46 4.87 0.60 0.37 0.74 10.86
. 17.46 4.87 0.60 2.00 2.00 1.49 1.30 16.62 17.18 0.32 0.00
.1.62 1.62 0.46 1.39 8.17 4.46 0.00 0.00 1.49 1.30 16.62 17.18 0.32 0.00 0.46 1.39 8.17 4.46 0.00 0.00 16.11
Dresden Nuclear Station 35 ft. Wind Speed and Direction January-March.
2003 15OFt-35Ft Delta-T (F)
SPEED WIND DIRECTION CLASSES
STABILITY CLASSES ----------
CLASS N
NNE NE ENE E
NWNNW TOTAL EU MU SU N
2 SS 4 MS ES 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.23 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.05 0.00 0.09 0.00 0.00 0.00 0.14 0.00 0.05 0.09 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.14 0.14 0.05 0.05 0.46 0.19 0.00 0.00 0.05 0.05 0.46 0.19 0.00 0.00 0.88 EU G MU T SU N
2 SS 4 MS ES 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 TOT 4.13 3.57 6.45 2.37 3.76 3.48 2.55 5.94 7.61 6.78 6.69 4.74 10.45 12.44 9.89 9.15 100.00 4.27 2.37 3.48 37.84 43.87 6.87 1.30 100.00 Wind Direction by Stability N
NNE NE ENE E
SSW SW WSW W WNW NW NNW TOTAL 0.14 0.09 0.09 2.55 1.16 0.05 0.05 0.09 0.14 0.05 2.23 0.97 0.09 0.00 0.51 0.05 0.19 3.81 1.86 0.05 0.00 0.00 0.05 0.09 1.25 0.88 0.09 0.00 0.00 0.00 0.00 1.21 2.04 0.42 0.09 0.00 0.05 0.00 0.84 2.04 0.37 0.19 0.00 0.05 0.09 0.74 0.97 0.70 0.00 0.00 0.00 0.05 2.04 2.83 0.88 0.14 0.00 0.05 0.09 2.79 3.90 0.74 0.05 0.05 0.32 0.23 2.27 2.46 1.21 0.23 0.28 0.14 0.51 2.74 2.23 0.56 0.23 0.19 0.14 0.42 1.76 1.67 0.51 0.05 0.60 0.19 0.23 2.88 5.99 0.42 0.14 1.11 0.37 0.70 3.76 6.08 0.37 0.05 0.84 0.56 0.42 2.88 4.83 0.32 0.05 0.46 0.19 0.32 4.09 3.95 0.09 0.05 4.27 2.37 3.48 37.84 43.87 6.87 1.30
-STABILITY CLASSES-Extremely Unstable Moderately Unstable Slightly Unstable Neutral Slightly Stable Moderately Stable Extremely Stable Wind Direction by Wind Speed N
NNE NE ENE E
SSW SW WSW W WMJ NW NNW TOTAL 0.00 0.28 1.86 1.49 0.51 0.00 0.00 0.00 0.37 1.39 1.25 0.56 0.00 0.00 0.00 0.28 1.35 2.97 1.86 0.00 0.00 0.00 0.37 1.30 0.70 0.00 0.00 0.00 0.00 0.37 1.95 1.30 0.14 0.00 0.00 0.00 0.60 1.81 0.97 0.09 0.00 0.00 0.00 0.37 1.25 0.65 0.28 0.00 0.00 0.00 0.56 2.69 1.39 1.07 0.23 0.00 0.00 0.32 2.51 3.30 1.44 0.05 0.00 0.00 0.60 2.27 2.41 1.35 0.14 0.00 0.00 0.46 1.72 2.04 2.14 0.32 0.00 0.00 0.60 1.39 1.49 1.25 0.00 0.00 0.00 0.97 2.92 4.97 1.53 0.05 0.00 0.00 0.84 3.76 4.78 3.02 0.05 0.00 0.00 0.93 4.04 4.60 0.28 0.05 0.00 0.00 0.74 3.20 4.60 0.60 0.00 0.00 0.00 8.68 35.42 38.90 16.11 0.88 0.00
-WIND SPEED CLASSES-C A L M
< 3.5 mph 3.6 -
7.5 mrph 7.6 - 12.5 mph 12.6 - 18.5 mph 18.6 - 24.5 mph
> 24.5 mph
Dresden Nuclear Station 300 ft. Wind Speed and Direction January-March. 2003 300Ft-35Ft Delta-T (F)
Nuffber of Observatlons -
2157 Values are Percent Occurrence SPEED ------------------
WIND DIRECTION CLASSES------------------
STABILITY CLASSES------
CLASS N
NNE NE ENE E ESE SE SSE 5 SSW SW WSWW WNW N.4 NNWl TOTAL EU MU SU N Ss P's ES TOTAL EU MU C SU A N L SS MMs ES EU MU 1 SU
- N 3 SS MS ES 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.09 0.09 0.00 0.00 EU 0.00 mu 0.00 4 SU 0.05 N 0.46 7 SS 0.05 Ms 0.05 ES 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.09 0.00 0.00 0.00 0.00 0.00 0.00 0.14 0.00 0.00 0.00 0.00 0.00 0.00 0.97 0.05 0.00 0.00 0.00 I0.00 0.14 10.60
- 0.19 10.00 I0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.05 0.00 0.37 0.09 0.05 0.00 0.00 0.09 0.05 0.79 0.42 0.00 0.00
- 0. 23
- 0.
05 0.0S 1.1if 0.3 0.0cC 0.00 0.00 0.00 I 0.00 0.00I 0.00I 0.00 0.00
- 0.
00 0.00 0.00 0.05 0.14 0.05 0.00 0.00 0.00 0.09 0.32 0.37 0.09 0.00 0.05 0.00 0.05 1.07 0.19 0.00 0.00 0.00 0.00 0.00 1.21 0.05 0.00 I0.00
).
00 1.00 1.00 1.00
).
00 0.00 0.00 0.00 0.00 0.00 0.05 0.14 0.00 0.00 0.00 0.00 0.00 0.23 0.28 0.00
- 0.
05 0.00 0.00 0.00 0.51 0.14
- 0.
05 0.00 0.00 0.00 0.00 0.56 0.26 0.09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.09 0.00 0.00 0.00 0.00 0.05 0.23 0.14 0.05 0.05 0.00 0.00 0.00 0.19 0.51 0.05 0.00 0.00 0.00 0.00 P0.09 10.42 10.00 I0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.05 0.70 0.51 0.00 0.00 0.00 0.05 0.05 0.42 0.74 0.05 0.00 0.00 0.00 0.00 0.23 0.83 0.28 0.00 0.00I 0.00 0.00I 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.19 0.23 0.00 0.00 0.00 0.00 0.09 0.32 0.60 0.09 0.05 0.00 0.00 0.00 0.74 0.32 0.28 0.00 0.00 0.00 D. 00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.05 0.05 0.00 0.00 0.00 0.00 0.46 0.09 0.09 0.05 0.00 0.00 0.14 1.44 0.97 0.14 0.00 0.00 0.0DC
- 0. 00 1.44
- 0. 74 0.2 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.14 0.09 0.00 0.00 0.00 0.00 0.00 1.07 0.70 0.23 0.09 0.00 I0.05 0.28 1.39 0.83 10.70 I 0.19 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
- 0. 05 0.00 0.00 0.00 0.00 0.00 0.05 0.19 0.19 0.09 0.00 0.00 0.00 0.05 0.83 0.32 0.05 0.00 0.00 0.05 0.23 1.56 0.86E 0.26 0.09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
- 0.
05 0.00 0.00 0.00 0.00 0.05 0.09 0.32 0.09 0.09 0.00 0.00 0.09 0.09 0.42 0.23 0.46 0.00 0.00 I0.00 I 0. 05 10.65 0.79 0.28 i0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00.0.00 0.00 0.00 0.00 0.00 0.05 0.14 0.00 0.05 0.09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 EU MU 8 SU
- N I Ss 2MS ES EU 1mu 3 SU
- N 1ISS ES 0.00 0.00 0.09 0.60 0.42 0.00 0.00 0.00 0.00 0.05
- 1.
56
- 0. 5E 0.00(
0.0 0.00 0.00 O.0D9 0.65 0.19 0.14 0.05
- 0.
05 0.05 0.05 1.07 0.51 0.14 0.00 0.05 0.09 0.09 1.34 0.70 0.23 0.00 0.00 0.00 0.05 0.56 0.23 0.00 0.00 0.00 0.19 0.14 1.16 0.46 0.28 0.05 0.09 0.14 0.42 2.18 2.04 0.14 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.09 0.51 0.19 0.05 0.00 0.00 0.23 0.14 1.21 0.79 0.23 0.00 0.00 0.14 0.37 2.27 2.09 0.19 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.09
- 0.
05 0.00 0.00 0.00 0.00 0.05 0.65 0.14 0.05 0.00 0.00 0.19 0.32 1.53 0.46 0.05 0.00 0.00 0.09 0.19 3.11 1.44 0.09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.79 0.70 0.19 0.00 0.00 0.00 0.14 0.65
- 6. 12 2.87 0.74 0.19 0.09 0.09 0.88 1.25 13.58 7.51 1.81 0.19 0.37 0.37 0.65 1.95 20.12 12.52 2.83 0.23 0.00 0.00 0.00 0.00 0.79 0.70 0.19 0.00 1.67 0.00 0.00 0.00 0.14 0.65 6.12 2.87 0.74 0.19 10.71 0.00 0.00 0.88 1.25 13.58 7.51 1.81 0.19 25.31 0.65 1.95 20.12 12.52 2.83 0.23 38.66
Dresden Nuclear Station 300 ft. Wind Speed and Direction January-March.
2003 300Ft-35Ft Delta-T (F)
STABILITY CLASSES ---------
SPEED
..................--..-..-----.-- - WIND DIRECTION CLASSES CLASS N
SSW SW WSW W WNW Rd NNW TOTAL EU MU SU N
2 SS 4MS ES 0.00 0.00 0.00 0.51 0.05 0.00 0.00 0.00 0.00 0.05 0.88 0.05 0.00 0.00 0.00 0.05 0.00 1.95 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.23 0.09 0.00 0.00 0.00 0.00 0.00 0.28 0.09 0.00 0.00 0.00 0.00 0.00 0.14 0.19 0.00 0.00 0.00 0.00 0.05 0.37 0.09 0.05 0.00 0.00 0.00 0.00 0.79 0.32 0.28 0.00 0.00 0.14 0.05 0.19 0.65 0.09 0.00 0.00 0.09 0.14 1.16 0.32 0.00 0.00 0.00 0.05 0.09 0.14 0.14 0.05 1.02 0.46 0.37 0.65 0.00 0.00 0.00 0.00 0.23 0.23 0.19 2.13 1.44 0.00 0.00 0.19 0.09 0.00 0.51 0.23 0.05 0.05 0.00 0.00 0.14 0.88 0.51 0.00 0.00 0.46 0.83 0.79 11.54 5.05 0.46 0.05 0.46 0.83 0.79 11.54 5.05 0.46 0.05 19.19 EU G MU T SU N
2 SS 4 MS ES 0.00 0.00 0.00 0.23 0.00 0.00 0.00 0.00 0.00 0.00 0.37 0.00 0.00 0.00 0.00 0.00 0.00 0.19 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.09 0.09 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.42 D.00 0.00 0.00 0.00 0.00 0.05 0.05 0.00 0.00 0.00 0.09 0.09 0.14 0.19 0.00 0.00 0.00 0.05 0.00 0.14 0.05 0.00 0.00 0.00 0.05 0.05 0.19 0.46 0.00 0.00 0.00 0.14 0.09 0.70 0.14 0.00 0.00 0.00 0.00 0.00 0.28 0.00 0.00 0.00 0.00 0.00 0.00 0.09 0.00 0.00 0.00 0.00 0.00 0.32 0.32 2.50 1.30 0.00 0.00 0.32 0.32 2.50 1.30 0.00 0.00 4.45 TOT 4.91 3.52 6.07 3.76 2.69 2.23 4.27 3.71 7.83 7.00 7.09 5.61 7.70 13.58 9.92 10.11 100.00 0.93 2.83 4.96 54.66 29.95 6.03 0.65 100.00 Wind Direction by Stability N
SSW SW WSW W WNW NW NNX TOTAL 0.00 0.00 0.23 3.48 1.16 0.05 0.00 0.00 0.00 0.19 3.06 0.28 0.00 0.00 0.23 0.28 0.14 4.45 0.93 0.05 0.00 0.05 0.00 0.14 2.69 0.74 0.14 0.00 0.00 0.00 0.00 1.58 0.93 0.14 0.05 0.00 0.00 0.05 0.79 1.25 0.09 0.05 0.00 0.05 0.09 1.48 2.32 0.32 0.00 0.00 0.05 0.23 1.72 1.25 0.42 0.05 0.00 0.00 0.14 4.22 2.60 0.83 0.05 0.00 0.19 0.32 2.87 2.32 1.02 0.28 0.00 0.23 0.56 3.94 1.90 0.42 0.05 0.00 0.14 0.28 0.32 0.37 0.32 2.60 3.76 1.53 2.50 0.83 0.60 0.00 0.05 0.32 0.70 0.88 6.86 4.36 0.42 0.05 0.19 0.46 0.60 4.82 3.29 0.51 0.05 0.00 0.28 0.70 6.35 2.60 0.19 0.00 0.93 2.83 4.96 54.66 29.95 6.03 0.65
-STA31LITY CLASSES-Extremely Unstable Moderately Unstable Slightly Unstable Neutral Slightly Stable Moderately Stable Extremely Stable Wind Direction by Wind Speed N
SSW SW WSW W WNW NW NNW TOTAL 0.00 0.19 0.60 1.11 2.23 0.56 0.23 0.00 0.09 0.14 1.02 0.93 0.97 0.37 0.00 0.05 0.56 1.34 1.95 1.99 0.19 0.00 0.23 0.88 1.34 1.25 0.05 0.00 0.00 0.19 0.56 0.70 0.93 0.32 0.00 0.00 0.09 0.51 0.74 0.51 0.37 0.00 0.00 0.05 1.25 1.30 1.34 0.32 0.00 0.00 0.00 0.46 1.16 1.34 0.56 0.19 0.00 0.14 0.70 2.69 2.46 1.39 0.46 0.00 0.05 0.23 2.09 3.43 1.11 0.09 0.00 0.05 0.51 1.25 3.06 1.72 0.51 0.00 0.05 0.65 1.30 1.76 1.62 0.23 0.00 0.14 1.11 1.85 2.50 1.34 0.74 0.00 0.19 0.83 2.27 5.01 4.22 1.07 0.00 0.05 0.83 2.60 5.05 1.11 0.28 0.00 0.14 0.88 2.55 4.91 1.53 0.09 0.00 1.67 10.71 25.31 38.66 19.19 4.45
-WIND SPEED CLASSES-C A L M 3,5 mph 3.6 -
7.5 mph 7.6 - 12.5 mph 12.6 - 18.5 mrph 18.6 - 24.5 mph
>24.5 mph
Dresden Nuclear Station 35 ft. Wind Speed and Direction April-June.
2003 15OFt-35Ft Delta-T (F)
Nurrber of Observations -
2173 Values are Percent Occurrence SPEED -------
CLASS N
NNE NE
WIND DIRECTION CLASSES ENE E
STABILITY CLASSES ----------
EU MU SU N
SS MS ES TOTAL SW WSW W 6WN NW NNW TOTAL EU MU C SU A N L SS mHS ES 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 EU MU I SU N
3 SS MS ES 0.00 0.00 0.05 0.37 1.01 0.92 0.05 0.00 0.00 0.09 0.51 1.10 0.55 0.05 0.00 0.00 0.05 0.37 0.60 0.09 0.00 0.00 0.00 0.00 - 0.05 0.00 0.00 0.18 0.28 0.14 0.14 0.23 0.23 0.00 0.00 0.00 0.00 0.00 0.14 0.00 0.28 0.00 0.00 0.00 0.00 0.18 0.28 0.05 0.23 0.00 0.00 0.00 0.14 0.28 0.37 0.14 0.00 0.00 0.00 0.09 0.37 0.46 0.28 0.05 0.00 0.00 0.18 0.18 0.14 0.05 0.00 0.00 0.00 0.14 0.28 0.18 0.41 0.05 0.00 0.05 0.09 0.28 0.14 0.28 0.05 0.00 0.00 0.18 0.14 0.09 0.28 0.00 0.00 0.00 0.14 0.28 0.32 0.14 0.00 0.00 0.00 0.09 0.28 0.83 0.64 0.00 0.00 0.00 0.64 0.78 0.78 0.60 0.14 0.05 0.23 3.73 6.12 5.66 3.13 0.14 0.05 0.23 3.73 6.12 5.66 3.13 19.05 EU MU 4 SU
- N 7 SS ES ES 0.23 0.00 0.14 1.15 0.69 0.14 0.00 0.37 0.14 0.14 1.89 1.89 0.28 0.00 1.47 0.55 0.41 2.67 3.64 0.09 0.05 1.29 0.41 0.23 1.20 2.21 0.05 0.00 0.18 0.09 0.05 0.92 2.25 0.09 0.09 0.14 0.09 0.09 0.74 1.24 0.51 0.00 0.05 0.00 0.00 0.28 0.28 0.18 0.09 0.18 0.05 0.05 0.41 0.69 0.55 0.00 0.00 0.05 0.00 0.18 1.01 0.69 0.00 0.05 0.00 0.05 0.23 0.60 0.46 0.09 0.05 0.00 0.05 0.18 0.78 0.60 0.23 0.09 0.05 0.05 0.46 0.41 0.09 0.00 0.00 0.05 0.05 0.69 0.92 0.09 0.00 0.09 0.09 0.09 0.64 0.46 0.55 0.05 0.23 0.09 0.05 0.28 0.37 0.05 0.00 0.46 0.00 0.00 0.64 0.74 0.05 0.00 4.B8 4.88 1.66 1.43 12.56 18.18 4.46 0.60 1.66 1.43 12.56 18.18 4.46 0.60 43.76 EU MU 8 SU N
1 SS 2 MS ES 0.28 0.09 0.00 0.32 0.18 0.00 0.00 0.69 0.09 0.00 0.97 0.05 0.00 0.00 1.15 0.14 0.28 1.61 0.69 0.00 0.00 0.23 0.09 0.18 1.01 0.92 0.00 0.00 0.14 0.14 0.09 1.56 1.24 0.05 0.00 0.00 0.05 0.05 0.69 0.69 0.09 0.00 0.00 0.00 0.00 0.23 0.41 0.00 0.00 0.00 0.05 0.09 0.69 1.06 0.05 0.00 0.09 0.09 0.05 0.37 0.78 0.09 0.00 0.37 0.23 0.14 0.37 0.55 0.09 0.00 0.05 0.00 0.09 0.14 0.51 0.28 0.00 0.37 0.23 0.09 0.55 0.46 0.00 0.00 0.05 0.05 0.14 0.28 0.32 0.00 0.00 0.09 0.00 0.05 0.55 0.28 0.00 0.00 0.28 0.14 0.00 0.51 0.32 0.00 0.00 0.46 0.18 0.28 0.32 0.32 0.00 0.00 4.23 4.23 1.56 1.52 10.17 8.79 0.64 0.00 1.56 1.52 10.17 8.79 0.64 0.00 26.92 EU 1MU 3 SU N
1 SS aK5 ES 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.05 0.05 0.00 0.00 0.09 0.05 0.00 0.32 0.09 0.00 0.00 0.00 0.05 0.00 0.41 0.28 0.00 0.00 0.00 0.00 0.00 0.18 0.09 0.00 0.00 0.00 0.00 0.00 0.14 0.18 0.00 0.00 0.05 0.14 0.05 0.37 0.64 0.00 0.00 0.14 0.23 0.09 0.74 0.46 0.00 0.00 0.09 0.14 0.05 0.28 0.18 0.00 0.00 0.41 0.05 0.09 0.51 0.00 0.00 0.00 0.05 0.00 0.00 0.14 0.09 0.00 0.00 0.37 0.14 0.05 0.28 0.14 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.00 1.24 1.24 0.78 0.32 3.45 2.25 0.00 0.00 0.78 0.32 3.45 2.25 0.00 0.00 8.05
Dresden Nuclear Station 35 ft. Wind Speed and Direction April-June.
2003 15OFt-35Ft Delta-T (F)
SPEED WIND DIRECTION-CLASSES ----------------------------------
STABILITY CLASSES ----------
EU MU SU N
SSW SW WSW W WNW NW NNW TOTAL EU 1MU 9 SU
- N 2 SS 4MS ES 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.14 0.00 0.00 0.05 0.00 0.05 0.32 0.32 0.00 0.00 0.05 0.05 0.00 0.18 0.05 0.00 0.00 0.00 0.00 0.00 0.05 0.18 0.00 0.00 0.00 0.00 0.00 0.32 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.09 0.09 0.05 0.05 0.87 0.69 0.00 0.00 0.05 0.05 0.87 0.69 0.00 0.00 1.75 EU G MJ T SU N
2 SS 4 MS ES 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.32 0.00 0.00 0.00 0.00 0.00 0.00 0.09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.41 0.05 0.00 0.00 0.00 0.00 0.41 0.05 0.00 0.00 0.46 TOT 5.61 8.79 13.90 8.47 8.15 5.52 2.53 5.11 6.03 6.21 5.02 5.34 4.05 4.79 4.19 6.30 100.00 10.58 4.10 3.54 31.20 36.08 10.77 3.73 100.00 Wind Direction by Stability N
SSW SW WSW W WNW NW NNW TOTAL 0.51 0.09 0.18 1.84 1.69 1.06 0.05 1.06 0.23 0.23 3.36 3.04 0.83 0.05 2.62 0.69 0.74 4.65 4.97 0.18 0.05 1.52 0.51 0.41 2.44 3.31 0.28 0.00 0.41 0.32 0.14 3.08 3.73 0.37 0.09 0.14 0.18 0.14 1.98 2.21 0.87 0.00 0.05 0.00 0.00 0.87 1.06 0.23 0.32 0.18 0.09 0.14 1.38 2.21 0.97 0.14 0.14 0.28 0.09 1.01 2.99 1.24 0.28 0.64 0.46 0.32 1.84 2.12 0.69 0.14 0.23 0.18 0.18 0.92 1.79 1.06 0.64 0.92 0.32 0.28 1.98 1.33 0.23 0.28 0.14 0.55 0.09 0.23 0.18 0.18 1.70 1.61 1.47 1.15 0.1B 0.87 0.28 0.18 0.51 0.23 0.05 0.92 0.97 0.87 0.64 0.97 0.18 0.28 1.61 1.84 0.83 0.60 10.58 4.10 3.54 31.20 36.08 10.77 3.73
-STABILITY CLASSES-Extremely Unstable Moderately Unstable Slightly Unstable Neutral Slightly Stable Moderately Stable Extremely Stable Wind Direction by Wind Speed N
NNE NE ENE E
WNW NW NNW TOTAL 0.00 2.39 2.35 0.87 0.00 0.00 0.00 0.00 2.30 4.69 1.79 0.00 0.00 0.00 0.00 1.10 8.88 3.87 0.05 0.00 0.00 0.00 0.55 5.38 2.44 0.09 0.00 0.00 0.00 0.69 3.68 3.22 0.55 0.00 0.00 0.00 0.41 2.81 1.56 0.74 0.00 0.00 0.00 0.74 0.87 0.64 0.28 0.00 0.00 0.00 0.92 1.93 1.93 0.32 0.00 0.00 0.00 1.20 1.93 1.47 1.24 0.14 0.05 0.00 0.60 1.47 1.75 1.66 0.74 0.00 0.00 1.01 1.89 1.06 0.74 0.32 0.00 0.00 0.87 1.15 1.70 1.06 0.23 0.32 0.00 0.74 1.79 0.83 0.28 0.32 0.09 0.00 0.87 1.98 0.97 0.97 0.00 0.00 0.00 1.84 1.06 1.24 0.05 0.00 0.00 0.00 2.81 1.89 1.56 0.05 0.00 0.00 0.00 19.05 43.76 26.92 8.05 1.75 0.46
-WIND SPEED CLASSES-CALH
< 3.5 irph 3.6 -
7.5 nph 7.6 - 12.5 rrph 12.6 - 18.5 mph 18.6 - 24.5 mph
> 24.5 mph
Dresden Nuclear Station 300 ft. Wind Speed and Direction April-June.
2003 300Ft-35Ft Delta-T (F)
Nurber of Observations -
2179 Values are Percent Occurrence SPEED
WIND DIRECTION CLASSES ----------------------------------
STABILITY CLASSES ----------
CLASS N
SSW SW WSW W WNW Nd NNW TOTAL EU MU SU N
SS MS ES TOTAL EU MU C SU A N L SS MMS ES 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 EU MU I SU N
3 SS MS ES 0.00 0.00 0.00 0.05 0.00 0.05 0.00 0.00 0.00 0.00 0.09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.05 0.00 0.00 0.00 0.00 0.09 0.05 0.18 0.00 0.00 0.00 0.00 0.09 0.09 0.05 0.00 0.00 0.00 0.00 0.05 0.00 0.05 0.00 0.00 0.00 0.00 0.05 0.05 0.00 0.00 0.00 0.00 0.05 0.05 0.05 0.00 0.00 0.00 0.00 0.00 0.14 0.14 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.09 0.00 0.05 0.00 0.00 0.05 0.00 0.05 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.05 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.05 0.05 0.09 0.05 0.78 0.46 0.41 0.05 0.09 0.05 0.78 0.46 0.41 0.05 1.88 EU MU 4 SU N
7 SS MS ES 0.00 0.00 0.00 0.55 0.05 0.14 0.00 0.00 0.05 0.14 0.64 0.18 0.18 0.00 0.05 0.14 0.18 0.64 0.37 0.00 0.00 0.18 0.28 0.73 1.33 1.15 0.05 0.00 0.05 0.18 0.09 0.64 0.32 0.14 0.00 0.05 0.05 0.05 0.32 0.05 0.00 0.00 0.00 0.00 0.14 0.37 0.18 0.05 0.00 0.00 0.14 0.09 0.46 0.09 0.09 0.05 0.00 0.00 0.00 0.09 0.09 0.05 0.00 0.00 0.00 0.00 0.18 0.09 0.05 0.00 0.00 0.00 0.00 0.14 0.09 0.09 0.00 0.00 0.05 0.05 0.18 0.23 0.05 0.14 0.00 0.05 0.00 0.28 0.28 0.23 0.05 0.00 0.00 0.05 0.28 0.05 0.05 0.00 0.00 0.00 0.09 0.18 0.05 0.14 0.00 0.05 0.09 0.09 0.32 0.14 0.23 0.00 0.37 0.37 1.01 1.70 6.61 3.40 1.51 0.23 1.01 1.70 6.61 3.40 1.51 0.23 14.82 0.09 0.05 0.14 0.92 0.50 0.14 0.09 0.05 0.14 0.14 1.28 1.10 0.28 0.00 0.46 0.28 0.55 2.94 1.97 0.64 0.05 0.09 0.78 0.55 3.40 1.47 0.00 0.00 0.14 0.05 0.37 1.06 0.96 0.23 0.05 0.00 0.09 0.05 0.78 0.28 0.05 0.00 0.00 0.00 0.00 0.46 0.28 0.50 0.00 0.00 0.00 0.05 0.55 0.28 0.32 0.09 0.00 0.00 0.00 0.14 0.32 0.18 0.00 0.05 0.09 0.05 0.32 0.50 0.05 0.05 0.00 0.00 0.00 0.09 0.37 0.41 0.18 0.00 0.14 0.23 0.28 0.46 0.18 0.09 0.00 0.05 0.14 0.73 0.37 0.14 0.05 0.00 0.00 0.23 0.37 0.37 0.05 0.05 0.00 0.18 0.23 0.18 0.05 0.05 0.05 0.09 0.18 0.05 0.28 0.00 0.09 0.00 0.96 0.96 2.02 2.75 13.77 9.27 3.30 0.73 2.02 2.75 13.77 9.27 3.30 0.73 EU 1 MU 3 SU N
1 SS 8MS 0.14 0.09 0.28 0.46 0.55 0.50 0.28 0.18 0.14 1.65 1.65 0.32 0.32 0.18 0.14 2.07 1.51 0.41 0.05 0.00 0.00 1.01 0.05 0.00 0.05 0.14 0.23 1.97 0.96
.0.00 0.00 0.00 0.00 0.73 0.69 0.32 0.00 0.00 0.09 0.55 0.32 0.28 0.00 0.05 0.23 0.50 0.09 0.23 0.00 0.05 0.14 0.64 0.73 0.28 0.09 0.32 0.41 0.69 0.92 0.23 0.00 0.05 0.14 0.28 1.01 0.50 0.18 0.18 0.09 0.55 0.28 0.23 0.00 0.00 0.09 0.41 0.60 0.18 0.05 0.00 0.00 0.41 0.41 0.18 0.05 0.00 0.32 0.37 0.41 0.14 0.14 0.09 0.05 0.64 0.37 0.00 1.33 1.33 1.33 2.34 12.94 10.56 3.81 1.33 2.34 12.94 10.56 3.81 ES 0.00 0.00 0.09 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.09 0.05 0.00 0.09 0.00 0.37 0.37 32.68
Dresden Nuclear Station 300 ft. Wind Speed and Direction SPEED
WIND DIRECTION CLASSES CLASS N
NNE NE ENE E
SSW April-June.
2003 300Ft-35Ft Delta-T (F)
STABILITY CLASSES ----------
SW WSW W WNW NW NNW TOTAL EU MU SU N
- N 2 SS 4MS ES 0.00 0.00 0.00 0.32 0.14 0.00 0.00 0.23 0.09 0.05 0.41 0.14 0.00 0.05 0.14 0.09 0.05 0.32 0.05 0.05 0.00 0.00 0.00 0.00 0.14 0.00 0.00 0.00 0.00 0.00 0.05 0.69 0.14 0.00 0.00 0.00 0.00 0.00 0.64 0.05 0.00 0.00 0.00 0.00 0.00 0.23 0.14 0.18 0.00 0.00 0.00 0.00 0.09 0.37 0.00 0.00 0.00 0.00 0.05 0.18 0.83 0.28 0.00 0.00 0.05 0.18 0.50 0.69 0.18 0.00 0.05 0.00 0.18 0.46 0.46 0.32 0.00 0.09 0.14 0.23 0.46 0.09 0.00 0.00 0.05 0.05 0.00 0.28 0.00 0.00 0.00 0.18 0.00 0.00 0.37 0.00 0.09 0.00 0.00 0.00 0.00 0.78 0.18 0.14 0.00 0.14 0.09 0.00 0.32 0.00 0.00 0.00 0.87 0.87 0.50 0.78 6.20 3.26 1.24 0.05 0.50 0.78 6.20 3.26 1.24 0.05 12.90 EU G MU T SU N
2 SS 4 MS ES 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.09 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.09 0.00 0.00 0.00 0.00 0.00 0.00 0.14 0.00 0.00 0.00 0.00 0.00 0.00 0.09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.14 0.41 0.00 0.00 0.05 0.00 0.09 0.64 0.50 0.00 0.00 0.00 0.00 0.14 0.32 0.00 0.00 0.00 0.00 0.09 0.00 0.64 0.05 0.00 0.00 0.00 0.00 0.00 0.41 0.00 0.00 0.00 0.09 0.14 0.09 0.41 0.00 0.00 0.00 0.00 0.00 0.05 0.05 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.18 0.23 0.46 2.98 1.06 0.00 0.00 0.23 0.46 2.98 1.06 0.00 0.00 4.91 TOT 5.23 9.59 13.77 11.61 8.81 4.41 3.95 3.99 4.86 6.98 5.46 5.55 4.50 3.90 3.85 3.53 100.00 3.76 5.19 8.08 43.28 27.99 10.28 1.42 100.00 Wind Direction by Stability N
NNE NE ENE E
SSW SW WSW W WNW NW NNw TOTAL 0.23 0.14 0.41 2.29 1.24 0.83 0.09 0.55 0.46 0.55 4.13 3.07 0.78 0.05 0.96 0.69 0.92 5.97 3.95 1.15 0.14 0.32 1.06 1.28 5.97 2.75 0.23 0.00 0.23 0.37 0.73 4.54 2.48 0.41 0.05 0.05 0.14 0.09 2.66 1.06 0.41 0.00 0.00 0.00 0.23 1.74 0.96 1.01 0.00 0.00 0.18 0.41 1.65 0.92 0.64 0.18 0.00 0.05 0.18 1.33 2.52 0.78 0.00 0.18 0.46 0.73 2.34 2.71 0.50 0.05 0.05 0.09 0.46 1.38 1.93 1.38 0.18 0.28 0.64 0.60 2.16 1.10 0.46 0.32 0.09 0.14 0.23 2.11 1.24 0.55 0.14 0.32 0.14 0.37 1.84 0.83 0.37 0.05 0.05 0.18 0.69 1.56 0.73 0.46 0.18 0.46 0.46 0.18 1.61 0.50 0.32 0.00 3.76 5.19 8.08 43.28 27.99 10.28 1.42
-STABILITY CLASSES-Extremely Unstable Moderately Unstable Slightly Unstable Neutral Slightly Stable Moderately Stable Extremely Stable Wind Direction by Wind Speed N
SSW SW WSW W WI NW NNW TOTAL 0.00 0.09 0.73 1.93 2.02 0.46 0.00 0.00 0.09 1.19 2.98 4.22 0.96 0.14 0.00 0.09 1.38 6.88 4.73 0.69 0.00 0.00 0.32 3.72 6.29 1.10 0.14 0.05 0.00 0.23 1.42 2.85 3.35 0.87 0.09 0.00 0.09 0.50 1.24 1.74 0.69 0.14 0.00 0.09 0.73 1.24 1.24 0.55 0.09 0.00 0.14 0.92 1.28 1.15 0.46 0.05 0.00 0.28 0.23 0.64 1.84 1.33 0.55 0.00 0.00 0.32 1.10 2.66 1.61 1.28 0.00 0.18 0.32 1.06 1.97 1.47 0.46 0.00 0.00 0.09 0.05 0.69 0.87 1.38 1.47 1.61 1.33 1.01 0.37 0.78 0.41 0.00 0.00 0.41 1.06 1.06 0.64 0.73 0.00 0.09 0.46 0.73 1.38 1.10 0.09 0.00 0.05 0.92 0.69 1.28 0.55 0.05 0.00 1.88 14.82 32.81 32.68 12.90 4.91
-WIND SPEED CLASSES-C A L M c 3.5 mph 3.6 -
7.5 rph 7.6 -12.5 rph 12.6 - 18.5 Iph 18.6 - 24.5 nph
> 24.5 aph
Dresden Nuclear Station 35 ft. Wind Speed and Dlrectlor, July-Septeirber.
2003 15CFt-35Ft Delta-T (F)
Number of Observatiros -
2177 Values are Percent Occurrence SPEED --------------------------------- WIND OIECTMON CLASSES ----------------------------------
CLASS 1
SSW SW WSW W WNd Ilr NNW TOTAL STABILITY CLASSES ---------
EU MJ SU N
5S MS ES TOTAL EU C SU A N L SS ES 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.O0 0.00 0.00 0.00 0.00 0.00 0.00 0.0D 0.00 0.00 0.00 0.00 0.00 0.00 D.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.OC 0.00 C.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 C.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.CO 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.ec 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.0C 0.00 0.0o 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 o.o0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.C0 O.CC 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 O.0O 0.00 0.00 0.00 0.00 0.0O 0.00 0.00 0.OD 0.00 0.00 0.00 0.00 0.0D 0.00 C.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.C0 EU 0.09 IVU. 14 1 SU 0.14 N 0.37 3 SS 0.87
.X5 0.37 ES 0.18 EU MU 4SU
1 SS 2KS ES 0.87 0.09 0.05 C..23 0.46 0.05 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.05 0.OC 0.18 0.92 0.32 0.00 0.73 0.09 0.14 0.37 0.64 0.05 0.00 0.00 C.00 0.00 0.00 0.05 0.00 O.CO 0.05 0.00 0.05 0.18 0.46 0.09 0.05 0.60 0.23 0.18 1.75
'.70 0.23 0.00 0.46 0.05 0.09 0.14 0.14 0.00 0.00 0.00 0.05 0.00 0.14 0.18 0.14 0.09 0.87 0.05 0.05 1.06 2.30 0.00 0.00 0.37 0.05 0.05 0.32 0.00 0.00 0.00 0.00 0.05 0.05 C.23 0.32 0.18 0.14 0.28 0.09 0.32 0.78 1.19 0.14 0.00 0.23 0.14 0.00 0.09 0.29 0.05 0.00 0.00 0.00 0.05 0.09 0.18 0.32 0.05 0.32 0.00 0.09 0.64 1.38 0.87 0.18 0.09 0.09 0.00 0.37 0.41 0.00 0.05 0.M0 0.00 0.00 0.00 0.09 0.37 0.14 0.32 0.23 0.18 0.37 1.33 0.73 0.14 0.23 0.14 0.00 0.64 0.83 0.18 0.00 0.09 C.05 0.00 0.14 0.41 1.15 0.23 O.09 0.14 0.14 C.41 1.33 0.73 0.14 0.23 0.32 0.14 0.78 0.64 0.00 C.00 0.00 C.O0 0.00 0.00 C.00 0.05 0.28 0.23 0.64 0.51 0.69 0.64 0.51 0.32 O.I C. 18 0.05 0.18 0.18 0.14 0.51 0.51 1.61 1.56 0.SI 0.60 0.09 0.14
- 0. 18&~{73 0.23 0.09 0.18 0.23 0.69 0.83 0.96 0.73 0.00 0.09 0.00 0.00 0.00 0.00 0.00 0.23 0.64 0.64 0.55 0.18 0.18 C.18 0.69 1.29 1.10 0.51 0.41 0.00 0.09 0.83 0.23 0.05 0.00 0.05 0.00 0.00 0.46 0.37 0.64 0.51 0.14 0.18 0.26 1.06 0.83 0.28 0.00 0.69 0.23 0.14 0.55 0.05 0.05 0.00 0.00 0.00 0.00 0.14 0.73 0.64 0.14 0.00 0.05 0.00 0.14 0.70 0.46 0.14 0.23 D.60 0.23 0.09 0.14 0.14 1.01 0.83 1.52 1.79 0.32 0.28 0.0^ 0.05 0.00 0.09 0.00 0.37 0.83 0.69 0.64 0.32 0.16 0.23 0.28 0.73 0.23 0.00 0.18 0.14 0.00 0.23 0.14 0.05 0.00 0.09 0.09 0.00 0.32 1.24 0.69 0.28 0.87 0.18 0.05 0.41 0.83 0.0C 0.05 0.05 0.00 D.05 0.05 0.05 0.00 0.C0 0.37 0.37 0.55 0.32 3.49 9.19 8.04 3.95 6.75 6.75 2.20 2.48 10.89 20.49 6.16 1.29 5.'4 5.14 1.93 1.47 7.12 5.60 0.51 0.05 8.04 3.95 25.91 0.55 0.32 3.49 9.19 2.20 2.48 10.89 20.49 6.16 1.29 50.25 0.41 0.18 0.32 0.96 0.87 0.05 0.00 0.87 0.28 0.18 0.64 0.18 0.00
.0.00 1.47 7.12 5.60 0.51 0.05 21.82 EU 1MU 3 SU N
- SS 8 FS ES 0.O0 0.00 0.00 0.05 1G.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 D.00 c.00 0.00 0.OC 0.00 0.00 0.00 0.00 0.cc 0.oc 0.co 0.00 0.00 0.00 0.00 0.00 0.00 0.Co 0.CC 0.00 0.00 0.00 0.00 0.00 0.00 Q.00 0.00 0.00 0.00 0.00 0.00 0.00 C.00 0.14 0.05 0.05 0.05 0.00 0.00 0.00 0.00 0.00 0.^i5 0.09 0.18 0.00 0.00 0.37 0.09 0.00 C.28 0.00 0.00 0.00 0.28 0.00 0.09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 c.0o 0.00 0.00 0.00 0.05 0.00 0.00 0.23 0.00 0.00 0.00 0.30 0.00 0.00
,0.00 0.00 0.00 0.05 0.00 0.00 0.00
.0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 C.83.0.83 0.14 O.1B 0.64 0.la 0.00 0.05 0.14 0.18 0.64 0.18 0.00 0.u5 2.02
Dresden Naclear Station 35 ft. Wind Speed and Direction July-Sep-e nter.
2003 1SOFt-35Ft Delta-T (F)
SPEED --------------------------------- WIND DIRECTICN CLASSES STABILITY CLASSES ----------
CLASS N
SSW S' WSW W WNW Mi NNW TOTAL
_U MU SU N
N 2 SS 4 HS Is 0.00 O.Ca 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 C.00 0.00 0.00 0.00 0.03 0.00 0.00 0.00 0.00 0.00 0.0u 0.0C 0.00 0.00 0.00 0.00 o.0o 0.00 0.00 0.00 0.00 0.0o 0.00 0.00 0.00 0.0o 0.00 0.0o 0.0o o.co 0.00 0.00 0.0o 0.00 0.00 0.00 0.00 O.u0 0.03 0.00 0.00 0.00 0.00 o.o0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.30 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.03 0.00 0.00 0.00
.00 0.00 0.00 0.00 0.00 0.00 0.0o 0.00 0.03 0.00 0.00 0.00 0.00 0.00 0.D0 D.00 0.00 0.00 0.00 0U.0 0.00 0.00 0.00 0O.0 0.00 0.00 C.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0."0 0.00 0.00 0.00 C.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.0D 0.00 D.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.0D 0.00 0.00 0.00 0.00 0.00 0.00 0.0o 0.00 0.00 0.00 C.00 o.o0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.0o 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.03 0.00 0.00 0.00 0.00 0.00 0.00 0.00 D.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 C.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.0C 0.00 0.00 0.00 0.00 C.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.DO 0.00 0.00 0.00 0.00 EU G KU T SU N
2 SS 4 MS ES IJ.00 0.00 0.00 0.00 0.03 0.00 0.00 0.00 0.00 0.00 0.00 0.C0 0.00 0.00 0.00 0.00 0.00 0.03 0.00 0.00 0.0D TOT 3.95 3.54 6.43 5.70 4.55 5.19 5.93 7.44 7.76 8.50 8.18 6.48 8.18 7.53 5.33 5.33 IC3.O 13.09 4.82 4.46 22.14 35.46 14.70 5.33 100.00 I.ind Direction by Stability N
NNE NE ENE E
SSW S7W WSW W
W IJ WV 14Ni T07AL
-STABILITY CLASSES-0.96 0.23 0.18 0.60 2.38 0.41 0.18 0.73 0.14 0.14 0.55 1.61 0.37 C.00 1.10 0.28 0.32 2.07 2.30 0.32 0.05
!.24 0.14 0.09 1.52 2.48 0.14 0.09 0.51 0.28 0.37 1.10 1.79 0.37 0.14 0.41 0.C9 0.14 1.10 1.98 1.19 0.28 0.55 C.37 0.16 1.0; 2.25 1.29 0.28 0.55 0.55 0.32 1.38 2.39 1.88 0.37 0.32 1.29 0.28 0.37 0.41 0.41 i.5G~ E84 3.40 0 0YEO 1.19 1.33 0.60 0.46 0.87 0.18 0.37 1.75 2.16 1'.79 1.06
- 0. B7 0.41 0.41 2.07 1.24 0.96 0.51 0.69 0.41 0.46 2.34 3.12 1.01 0.14 1.47 0
0.1 0.32
'.61 2.76 0.73 0.23 0.51 0.41 0.23 0.87 1.70 0.96 0.64 1.01 0.28 0.09 0.78 2.11 0.73 0.32 13.09 4.82 4.46 22.14 35.46 14.70 5.33 Extremely Unstable Moderately Unstable Slightly Unstable Neutral Slightly Stable Moderately Stable Extrernely Stable Wind Direction by Wind Speea N
1NNE NE ENE E
SSW SW WSW W WVN 1`d NSd TOTAL 0.00 2.16 1.75 0.05 0.00 0.00 0.00 0.00 1.47 2.02 0.CS
- 0.
C0.
0.00 0.00 0.00 0.87 4.69 0.87 0.00 0.00 0.CO 0.00 0.63 4.32 0.78 0.00 0.00 0.00 0.00 0.96 2.80 0.78 0.00 0.00 0.00 0.00 0.69 3.49 1.01 0.00 0.00 0.00 0.00 0.60 3.31 2.02 0.00 O.0D 0.00 0.30 0.00 2.07 2.11 2.99 3.08
- 2. 11 2.25 0.28 0.32 0.00 0.00 0.00 0.00 0.00 1.75 3.3!
2.71 0.73 0.00 0.00 0.00 2.07 4.13 1.61 0.37 0.00 0.00 0.00 2.02 2.76 1.70 0.00 0.00 0.00 0.00 1.65 3.45 2.80 0.28 0.00 0.00 0.00 1.56 3.77 2.16 0.05 0.00 0.00 0.CO 2.62 1.99 0.73 0.00 0.00 0.00 0.00 2.71 2.43 0.18 0.00 0.00 0
.00 0.00 25.91 50.25 21.82 2.02 0.00 0.00
-WIND SPEED CLASSES-CA'. M
< 3.5 mh 3.6 -
7.5 nph 7.6 - 12.5 rph 12.6 - 18.5 rph 18.6 -24.5 rp^
>24.5 mph
Dresden Nuclear Station 300 ft. Wind Speed and Direction July-September.
2003 300Ft-35Ft Celta-T (F)
Nruber of Observations -
2202 Values are Percent Occurrence SPEED WIND DIRECTION CLASSES --------------------------------
STABILITY CLASSES --------
CLASS N
VWN'W NW iNW TOTAL ElU PU SU N
SS MS ES TOTAL EU MU C SL A N L SS M tS ES 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 CG.OD 0.00 0.00 0.0C 0.00 0.00 D. 00 0.00 0.00 0.00 0.00 0.00 0.CD 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
- 0.
C 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 C.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 C.00 C.00 0.00 0.00 0.00 0.00 o.o0 0.00 0.00 0.00 0.00 0.o0 0.00 0.00 0.00 0.00 0.00.
0.00 0.00 0.o0 0.00 0.00 0.00 0.00 0.00 0.00 o.00 0.00 C.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.0C 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.0o 0.00 0.00 0.00 0.0o 0.00 0.00 0.00 EU MJ ISu N
3 SS MS ES 0.00 0.00 0.00 0.09 0.00 0.00 0.00 0.00 0.G0 0.05 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.00
- 0. 14 0.05 S.OO 0.C0 0.00 0.00 0.14 S.09 0.00 0.00 0.00 0.0D 0.05 0.05 0.05 0.05 0.00 0.00 0.W0 0.00 0.09 0.00 0.05 0.00 0.00 0.00 0.00 0.10 0.00 0.09 0.00 0.00 0.00 0.00 0.05 0.09 0.00 0.0M 0.00 0.00 0.00 0.23 0.05 0.05 0.00 0.0C 0.00 0.00 0.27 0.09 0.05 0.00 0.00 0.00 M.CO 0.23 0.05 0.27 0.05 0.00 0.00 0.00 0.18
- 0. CO 0.05 0.00 0.00 0.00 O.CO 0.09 0.14 0.09 0.00 0.0C 0.00 0.00 0.09 0.00 0.14 0.00 0.00 0.00 0.00 0.S9 0.14 0.05 0.00 0.CO 0.CS 0.09 0.09 0.05 0.00 0.00 0.00 0.00 0.00 0.18 1.91 0.86 0.91 0.05 0.00 0.18 1.91 0.86 0.91 0.05 3.91 EL 4 SU N
1 Ss 2 MS ES 0.00 S.27 0.09 0.36 0.14 0.10 0.05 0.23 0.14 0.36 0.45 0.54 0.18 0.00 0.00 0.09 0.27 0.36 0.09 0.09 0.05 C.14 0.14 0.:8 0.86 0.64 0.36 0.05 0.00 0.09 0.C5 0.23 0.27 0.05 0.14 0.00 0.27 0.14 1.i4 1.04 0.'09 0.14 0.00 0.00 0.23 1.00 0.77 0.27 0.05 0.09 0.27 0.36 1.86 1.45 0.18 0.00 0.00 0.00 0.18 0.73 0.36 0.14 0.05 0.00 0.14 0.41 0.68 0.59 0.00 0.00 0.00 0.05 0.23 0.18 0.18 0.41 0.00 0.00 0.18 0.09 0.64 0.50 0.14 0.00 0.00 0.18 0.27 0.54 0.32 C.18 0.05 0.00 0.14 0.23 0.50 0.86 0.54 0.00 0.00 0.00 0.09 0.41 0.27 0.27 0.05 0.05 0.09 0.36 0.73 0.60 0.73 0.09 0.00 0.00 C0.05 0.45 0.27 0.18 0.00 0.00 0.05 0.27 0.36 0.36 0.14 o.ao 0.00 0.05 0.09 0.59 0.27 0.45 0.00 0.05 0.05 0.14 0.36 0.64 0.50 0.14 0.00 0.05 0.14 0.91 0.45 0.27 0.00 0.00 0.09 0.23 0.82 C.50 0.36 0,09 0.00 0.00 0.09 0.05 0.00 0.18 0.77 0.35 0.54 0.3Z 0.18 0.27 O.O, 0.00
'7 0.00 0.00 0.09 0.36 0.23 0.32 0.00 0.05 0.23 0.36 0.32 0.18 O.09 0.05 0.05 0.05 1.18 2.59 7.95 5.04 3.50.
0.45 1.18 2.59 7.95 5.04 3.50 0.45 20.75
- 0. 00 09 0.05 0.14 0.08 0.14 0.50 0.64 0.77 1.04 0.77 0.45 0.00 0.05 0.00 0.05 0.27 0.77 0.68 0.41 0.41 0.09 0.36 0.36 0.59 0.50 0.27 0.00 0.05 0.05 0.09 0.32 0.64 0.27 0.00 0.09 0.05 0.00 0.18 0.47 0.05 0.14 0.86 0.86 2.18 3.54 11.04 11.49 5.31 1.09 2.18 3.54 11.04 11.49 5.31 1.09 35.51 EU 1IMU 3 SU
- N 155 8aM ES 0.14 0.05 0.00 0.23 0.73 0.23 0.00 0.14 0.09 0.14 0.64 0.59 C.27 C.00 0.05 0.27 0.18 0.82 0.50 0.23 C.05 0.00 0.00 0.00 0.09 0.00 0.00 0.00 0.00 0.14 0.05 0.36 C.36 0.09 0.00 C.00 C.00 0.00 0.23 0:'54 0.'4 0.00 0.00 0.00 0.14 0.41 1.23 0.68 0.09 0.00 0.05 0.14 0.64 1.04 0.77 0.09 0.00 0.05 0.09 1.14 1.91 0.27 0:18 0.00 0.23 0.54 0.73 1.32 0.91 0.05 0.05 0.14 0.18 0.73 1.14 0.50 0.09 0.14 0.14 0.32 0.86 0.68 0.45 0.09 0.05 0.14 0.18 0.77 1.18 0.32 0.05 0.05 0.18 0.23
- 1. 18 1.32 0.27 0.00 0.00 0.05 0.14 0.35 0.68 0.45 C.00 0.00 0.05 0.05 0.14 0.59 0.00 0.00 0.59 0.59 1.54 2.36 9.31 13.81 5.59 C.6B 1.54 2.36 9.31 s
13.81 0.68 33.00
Drescen Nuclear Statlcn 300 ft. Wind Speed and Direction July-Septe-Der.
2003 300Ft-35Ft Delta-T (F)
SPEED
- WIND DIRECTI0N CLASSES STABILITY CLASSES ----------
CLASS H
SSW SW HSW H 14NMJ NX NWtd TOTAL EU MU SU N
SS I'S ES TOTAL EU I 1,lJ 9 SU N
2 SS 4 PS ES I.00 0.00 0.00 0.05 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.CD 0.CO 0.00 0.00 0.00 0.0G 0.00 0.00 0.00 0.00 O.CO 0.00 0.00 0.00 0.00 0.05 0.09 0.00 0.00 0.00 0.00 0.00 0.00 0.27 0.09 D.00 0.00 0.00 0.00 0.00 0.05 0.09 0.00 0.00 0.09 0.09 0.05 0.09 0.00 0.00 0.00 0.00 C.05 0.05 0.27 0.23 0.00 0.00 0.00 0.00 0.23 0.45 0.05 0.05 0.00 0.05 0.05 0.18 0.09 0.18 0.09 0.00 0.05 0.00 0.09 0.00 0.00 0.00 0.00 0.00 0.05 0.36 0.41 0.00 O.CO 0.14 0.i8 0.05 0.27 0.18 0.00 0.00 0.00 0.00 0.00 0.14 0.18 0.00 0.00 0.00 0.C0 0.05 0.00 0.23 0.05 O.CO 0.14. 0.14 0.36 0.32 1.45 2.36 0.73 0.14 0.36 0.32 1.45 2.35 0.73 0.14 5.50 EU G MU T SU N
2 Ss 4 1S ES 0.00 0.00 0.00 0.00 0.05 O.0O 0.00 0.00 0.00 0.00 0.00 O.00 0.00 O.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.o0 o.c0 0.0o 0.00 0.00 0.00 0.00 0.00
.o00 0.z0 0.oo 0.00 0.0o 0.00 0.00 0.00 0.00 0.0o 0.CD 0.0C 0.00 0.00 0.00 0.00 0.00 0.M0 0.00 0.00 0.00 0.05 0.05 0.00 0.09 0.05 0.00 0.00 0.00 C.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.13 0.00 0.00 0.00 3.00 0.00 0.00 0.00 C.00 C.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 C.00 0.00 0.00 0.09 0.14 0.18 0.05 0.00 I..00 0.09 D.14 0.18 0.05 0.00 0.45 TOT 4.59 5.31 5.90 6.86 4.59 4.00 6.77 6.99 7.90 8.76 7.40 6.95 8.04 7.67 4.72 3.54 100.00 1.63 5.27 9.C8 3:.79 33.74 16.00 2.41 10C.00 WinC DIrection by Stability N
NNE NE ENE E
SSW S1!
WSW 2' VM NW NNW TOTAL
-STABILITY CLASSES-0.36 0.45 0.45' 1.18 1.50 0.59 C.05 0.27 0.32 0.64 1.91 1.32 0.77 0.09 0.05 0.64 0.36 2.18 1.95 0.41 0.32 0.09 0.00 0.27 0.27 0.59 0.68 3.09 1.96 2.32 1.45 0.45 0.27 0.05 0.05 0.00 0.23 0.32 1.14 1.50 0.82 0.00 0.00 0.32 0.64 1.63 2.45 1.59 C.14 0.0i 0.23 0.68 1.86 2.18 1.77 0.23 0.00 0.09 0.09 0.41 0.36 1.00 2.1ir !L23 3.36 a'3.32 1.50 1.59 0.18 0.14 0.09 0.27 0.50 2.09 2.18 1.91 C.36 0.14 0.32 0.68 2.86 1.63 1.14 0.18 0.05 0.27 0.50 2.77 2.95 I.D4 0.45 0.27
-10. 77 0.82 2.54 2.32 0.95 0.00 0.05 0.09 C.32 1.32 1.86 1.09 0.00 0.14 0.32 0.54 0.73 1.45 C.19 0.18 1.63 5.27 9.08 31.79 33.74 16.08 2.41 Extrenely Unstable Moderately Unstable Slightly Unstable Neutral Slightly Stable M.oderately Stable Extre.ely Stable Wind Direction by Wind Speed N
NNE NE ENE E
.'W NWd NWNl TOTAL 0.00 0.09 1.09
- .91 1.36 0.09 0.05 0.00 0.09 0.95 2.36 1.86 0.05 0.00 0.00 0.18 0.82 2.82 2.09 0.00 0.00 C.00 C.23 2.32 4.22 0.09 0.00 0.00 0.00 0.18 1.45 1.82 1.00 0.14 0.00 0.00 0.14 1.04 1.54 0.91 0.36 0.00 0.00 0.27 1.54 2.27 2.54 0.14 0.00 0.00 0.14 1.09 2.72.
2.72 0.32 0.00 0.00 0.32 0.95 2.27 3.63 0.59 0.14 0.00 0.41 1.18 2.54 3.77 0.77 0.09 0.00 0.00 0.59 0.23
- .45 1.62 1.E6.. 2.09 2.82 2.0e 0.64 0.14 0.05 0.00 0.00 0.32 1.59 2.59 2.68 0.82 0.05 0.CO 0.23 1.18 2.18 3.22 0.82 0.05 0.00 0.27 1.03 1.41.
1.68 0.32 0.05 0.00 0.23 1.27 0.91 D.82 0.32 0.00 0.D0 3.91 20.75 35.51 33.68 5.50 0.45
-WIND SEE0 CLASSES-CALM
< 3.5 rp?.
3.6 -
7.5 iiph 7.6 -12.5 rmh 12.6 - 18.5 ffph 18.6 - 24.5 mph
> 2d.5 mph
Dresden Nuclear Station 35 ft. Wind Speed and Direction October-Decemrber.
2003 15OFt-35Ft Delta-T (F)
Number of Observations -
2177 Values are Percent Occurrence SPEED WIND DIRECTION CLASSES ----------------------------------
CLASS N
STABILITY CLASSES ---------
EU MU SU N
SS rS ES TOTAL EU C SU A ft L SS ES ES 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 EU MU I SU N
3 SS FS ES 0.05 0.00 0.05 0.05 0.26 0.09 0.05 0.00 0.00 0.00 0.18 0.37 0.05 0.00 0.00 0.05 0.00 0.09 0.55 0.18 0.00 0.05 0.00 0.00 0.05 0.28 0.09 0.00 0.00 0.00 0.00 0.00 0.23 0.05 0.05 0.00 0.00 0.00 0.09 0.28 0.14 0.09 0.00 0.05 0.00 0.09 0.09 0.23 0.09 0.00 0.00 0.00 0.18 0.18 0.32 0.00 0.00 0.00 0.00 0.05 0.23 0.37 0.18 0.00 0.00 0.00 0.05 0.32 0.18 0.41 0.00 0.00 0.00 0.09 0.14 0.18 0.46 0.00 0.00 0.00 0.09 0.32 0.23 0.09 0.00 0.00 0.00 0.09 0.51 0.2B 0.05 0.00 0.00 0.00 0.18 0.73 0.37 0.00 0.00 0.00 0.09 0.32 0.78 0.32 0.14 0.00 0.00 0.05 0.23 0.32 0.51 0.28 0.09 0.09 0.18 1.84 5.60 3.58 1.88 0.09 0.09 0.18 1.84 5.60 3.58 1.88 13.28 EU MU 4 SU N
7 SS Ms ES 0.51 0.09 0.09 0.55 0.73 0.05 0.00 0.05 0.00 0.00 0.23 0.23 0.00 0.00 0.18 0.05 0.00 0.41 0.64 0.00 0.00 0.28 0.05 0.09 0.55 0.60 0.00 0.00 0.18 0.05 0.00 1.79 1.56 0.05 0.05 0.18 0.14 0.09 1.01 1.56 1.01 0.23 0.09 0.09 0.09 0.41 0.78 0.73 0.00 0.05 0.00 0.14 0.78 0.87 0.18 0.00 0.00 0.00 0.05 0.60 0.41 0.23 0.00 0.00 0.00 0.00 0.46 0.87 0.18 0.05 0.00 0.05 0.00 0.46 0.87 0.41 0.28 0.14 0.05 0.05 0.69 0.64 0.23 0.05 0.18 0.14 0.23 1.15 1.42 0.55 0.05 0.14 0.00 0.18 1.06 1.65 0.73 0.00 0.09 0.05 O.18 1.19 2.02 0.05 0.05 0.46 0.14 0.00 1.15 1.15 0.14 0.00 2.53 2.53 0.87 1.19 12.49 16.03 4.55 0.73 0.87 1.19 12.49 16.03 4.55 0.73 38.40 EU MU 8 SU
- N 1 SS 2 MS ES 0.00 0.00 0.00 0.09 0.14 0.00 0.00 0.00 0.00 0.05 0.18 0.18 0.00 0.00 0.18 0.05 0.00 0.37 0.00 0.00 0.00 0.00 0.05 0.00 0.05 0.00 0.00 0.00 0.09 0.05 0.05 1.06 0.51 0.00 0.00 0.05 0.00 0.09 1.10 0.73 0.00 0.00 0.09 0.09 0.00 0.64 0.37 0.14 0.00 0.00 0.09 0.09 1.38 1.19 0.00 0.00 0.28 O.18 0.09 1.56 1.29 0.00 0.00 0.14 0.09 0.09 1.47 1.65 0.00 0.00 0.32 0.00 0.05 0.78 0.73 0.09 0.00 0.51 0.14 0.05 0.28 0.51 0.09 0.00 0.32 0.18 0.23 1.61 0.23 0.00 0.00 1.29 0.18 0.14 2.25 1.33 0.00 0.00 0.32 0.23 0.09 2.62 1.19 0.00 0.00 0.23 0.05 0.05 0.69 0.32 0.00 0.00 3.81 3.81 1.38 1.06 16.12 10.38 0.32 0.00 1.38 1.06 16.12 10.38 0.32 0.00 33.07 EU I MU.
3 SU N
1 SS 8 MS ES 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.14 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.09 0.00 0.00 0.00 0.00 0.00 0.00 0.23 0.09 0.00 0.00 0.00 0.00 0.05 0.92 0.46 0.00 0.00 0.14 0.14 0.14 1.10 0.83 0.00 0.00 0.32 0.05 0.05 1.19 0.55 0.00 0.00 0.09 0.09 0.14 0.32 0.23 0.00 0.00 0.14 0.05 0.00 0.14 0.23 0.00 0.00 0.28 0.00 0.05 1.19 0.05 0.00 0.00 0.14 0.28 0.05 0.05 0.00 0.05 0.87. 0.83 0.55 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.41 0.00 0.00 0.00 1.38 1.38 0.41 0.51 7.49 3.03 0.00 0.00 0.41 0.51 7.49 3.03 0.00 0.00 12.82
Dresden Nuclear Station 35 ft. Wind Speed and Direction October-December.
2003 ISOFt-35Ft Delta-T (F)
......... STABILITY CLASSES ----------
SPEED -------------------------------- WIND DIRECTION CLASSES CLASS N
NNE NE ENE E
SSW SW WSW W WNW NW NNW TOTAL EU MU SU N
2 SS 4MS ES 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.28 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.05 0.55 0.18 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.18 0.28 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.09 0.05 0.14 0.00 0.00 0.00 0.05 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.09 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.14 0.14 0.28 0.09 1.06 0.73 0.00 0.00 0.00 0.00 0.00 0.00 0.14 0.00 0.00 0.00 0.28 0.09 1.06 0.73 0.00 0.00 2.30 0.00 0.00 0.14 0.00 0.00 0.00 0.14 TOT 2.80 1.65 2.76 2.11 5.79 6.89 4.41 7.21 8.68 8.64 6.06 4.78 8.96 12.08 10.98 6.20 100.00 7.95 3.03 3.03 39.14 35.78 8.45 2.62 100.00 Wind Direction by Stability N
NNE NE ENE E
WNW NW NN14 TOTAL 0.55 0.09 0.14 0.69 1.15 0.14 0.05 0.05 0.00 0.05 0.73 0.78 0.05 0.00 0.37 0.14 0.00 0.87 1.19 0.18 0.00 0.32 0.09 0.09 0.64 0.87 0.09 0.00 0.28 0.09 0.05 2.89 2.30 0.09 0.09 0.23 0.14 0.18 2.30 2.57 1.15 0.32 0.18 0.23 0.09 1.38 1.33 1.10 0.09 0.05 0.09 0.28 3.31 2.99 0.51 0.00 0.41 0.37 0.32 3.86 2.94 0.60 0.18 0.46 0.18 0.14 3.35 3.67 0.37 0.46 0.51 0.28 0.18 1.70 1.98 0.69 0.73 0.83 0.23 0.09 1.24 1.70 0.55 0.14 0.78 0.37 0.55 4.13 2.20 0.83 0.09 1.56 0.23 0.32 4.59 4.27 1.10 0.00 0.69 0.32 0.41 4.96 4.04 0.37 0.18 0.69 0.18 0.14 2.48 1.79 0.64 0.28 7.95 3.03 3.03 39.14 35.78 8.45 2.62
-STABILITY CLASSES-Extremely Unstable Moderately Unstable Slightly Unstable Neutral Slightly Stable Moderately Stable Extremely Stable Wind Direction by Wind Speed N
NNE NE ENE E
WNW NW NN'` TOTAL 0.00 0.55 2.02 0.23 0.00 0.00 0.00 0.00 0.60 0.51 0.41 0.14 0.00 0.00 0.00 0.87 1.29 0.60 0.00 0.00 0.00 0.00 0.46 1.56 0.09 0.00 0.00 0.00 0.00 0.32 3.67 1.75 0.05 0.00 0.00 0.00 0.60 4.23 1.98 0.09 0.00 0.00 0.00 0.55 2.20 1.33 0.32 0.00 0.00 0.00 0.69 2.02 2.76 1.42 0.32 0.00 0.00 0.83 1.29 3.40 2.34 0.83 0.00 0.00 0.96 1.56 3.45 2.16 0.51 0.00 0.00 0.87 2.07 1.98 0.87 0.28 0.00 0.00 0.73 1.84 1.56 0.55 0.09 0.00 0.00 0.92 3.72 2.57 1.56 0.09 0.09 0.00 1.29 3.77 5.19 1.61 0.18 0.05 0.00 1.65 3.63 4.46 1.24 0.00 0.00 0.00 1.38 3.03 1.33 0.46 0.00 0.00 0.00 13.28 38.40 33.07 12.82
'2.30 0.14
-WIND SPEED CLASSES-CALM
< 3.5 nMh 3.6 -
7.5 mph 7.6 - 12.5 uph 12.6 - 18.5 mrph 18.6 - 24.5 mph
> 24.5 mph
Dresden Nuclear Station 300 ft. Wind Speed and Direction October-Decerber.
2003 300Ft-3SFt Delta-T (F)
Nutber of Observations -
2202 Values are Percent Occurrence SPEED --
WIND DIRECTION CLASSES ----------------------------------
STABILITY CLASSES ----------
EU MU SU N
NNE NE ENE E
SSW SW WSW W WVrW NW NNX TOTAL EU MJ C SU A N L SS EMS ES 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
- 0. 00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0:00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 EU MU I SU N
3 SS MS ES 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.05 0.05 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.09 0.00 0.00 0.00 0.00 0.00 0.09 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.14 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.05 0.00 0.00 0.00 0.00 0:00 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.09 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.05 0.00 0.00 0.00 0.00 0.00 0.14 0.05 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.64 0.59 0.05 0.00 0.00 0.00 0.64 0.59 0.05 0.00 1.27 EU 0.00 MU 0.00 4 SU 0.14 N 0.36 7 SS 0.09 MS 0.09 ES 0.00 0.05 0.00 0.05 0.18 0.23 0.05 0.00 0.00 0.00 0.00 0.18 0.00 0.09 0.00 0.00 0.14 0.05 0.36 0.09 0.05 0.00 0.00 0.00 0.00 0.23 0.50 0.09 0.00 0.05 0.09 0.05 0.54 0.36 0.14 0.00 0.00 0.00 0.00 0.77 0.54 0.00 0.00 0.00 0.00 0.00 0.54 0.27 0.05 0.00 0.00 0.09 0.09 1.63 0.41 0.09 0.05 0.00 0.00 0.05 0.45 0.18 0.00 0.05 0.00 0.14 0.14 0.54 0.50 0.09 0.00 0.00 0.00 0.09 0.54 0.41 0.00 0.00 0.00 0.09 0.09 0.50 0.54 0.05 0.00 0.00 0.00 0.00 0.27 0.14 0.00 0.00 0.00 0.00 0.05 1.04 0.95 0.45 0.05 0.00 0.00 0.00 0.18 0.14 0.05 0.00 0.00 0.00 0.00 0.54 0.05 0.14 0.00 0.00 0.00 0.00 0.18 0.1B 0.05 0.00 0.00 0.05 0.23 0.82 0.41 0.09 0.05 0.00 0.00 0.00 0.27 0.36 0.14 0.00 0.00 0.05 0.18 0.23 0.41 0.18 0.32 0.00 0.00 0.00 0.32 0.32 0.00 0.14 0.05 0.00 0.14 0.68 0.50 0.32 0.23 0.00 0.00 0.00 0.59 0.23 0:09 0.09 0.00 0.14 0.05 1.27 0.95 0.27 0.00 0.00 0.05 0.00 0.45 0.27 0.05 0.00 0.00 0.14 0.18 0.91 0.59 0.14 0.00 0.00 0.00 0.05 0.64 0.23 0.00 0.00 0.00 0.00 0.09 1.23 0.73 0.05 0.00 0.00 0.09 0.18 0.50 0.23 0.05 0.00 0.00 0.23 0.05 1.09 0.23 0.14 0.00 0.09 0.09 0.36 0.64 6.40 3.72 0.77 0.27 0.05 0.05 1.14 1.36 12.03 7.72 2.27 0.68 0,36 0.64 6.40 3.72 0.77 0.27 12.26 EU MU 8 SU N
1 SS 2MS ES 0.00 0.23 0.09 0.36 0.41 0.09 0.00 1.14 1.36 12.03 7.72 2.27 0.68 25.25 EU 1IMU 3 SU N
I SS 8MS ES 0.00 0.00 0.00 0.14 0.54 0.32 0.27 0.00 0.00 0.00O 0.09 0.59 0.05 0.32 0.00 0.09 0.09 0.32 0.09 0.05 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.05 0.00 0.00 1.18 0.36 0.00 0.00 0.00 0.00 0.00 1.23 0.68 0.23 0.00 0.00 0.00 0.00 0.27 0.91 0.59 0.05 0.00 0.00 0.05 1.77 0.64 0.68 0.05 0.00 0.14 0.23 1.36 0.73 0.27 0.05 0.00 0.00 0.05 0.91 1.00 0.09 0.09 0.05 0.05 0.00 1.00 1.14 0.23 0.36 0.05 0.14 0.18 0.32 0.64 0.27 0.32 0.00 0.09 0.09 1.32 0.86 0.23 0.00 0.36 0.41 0.36 1.91 1.09 0.91 0.00 0.00 0.05 0.09 2.59 1.68 0.32 0.00 0.00 0.09 0.00 0.77 0.91 0.14 0.09 0.50 0.50 1.04 1.14 15.21 11.85 4.36 1.59 1.04 1.14 15.21 11.85 4.36 1.59
Dresden Nuclear Station 300 ft. Wind Speed and Direction October-Decerlber.
2003 300Ft-35Ft Delta-T (F)
SPEED
WIND DIRECTI1N CLASSES -------------------------------
STABILITY CLASSES ----------
CLASS N
NNE NE ENE E
SSW SW WSW W WhW NW NNW TOTAL EU MU SU N
- N 2 SS 4MS ES 0.00 0.00 0.00 0.09 0.14 0.14 0.00 0.00 0.00 0.00 0.18 0.27 0.00 0.00 0.00 0.00 0.00 0.09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.32 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.32 0.00 0.00 0.00 0.00 0.00 0.45 0.09 0.05 0.05 0.00 0.00 0.05 1.18 0.23 0.05 0.00 0.00 0.05 0.09 1.04 1.04 0.18 0.00 0.00 0.00 0.18 1.41 1.59 0.09 0.09 0.00 0.00 0.00 0.41 0.45 0.05 0.05 0.00 0.09 0.00 0.14 0.45 0.05 0.00 0.00 0.05 0.09 1.09 0.18 0.05 0.00 0.05 0.05 0.00 1.18 1.14 0.27 D.00 0.05 0.09 0.09 1.68 0.59 0.00 0.00 0.00 0.00 0.00 0.45 0.14 0.05 0.00 0.09 0.09 0.32 0.50 9.90 6.63 0.95 0.18 0.32 0.50 9.90 6.63 0.95 0.18 18.57 EU G HU T SU N
2 SS 4 MS ES 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.14 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.09 0.05 0.00 0.00 0.00 0.00 0.00 0.27 0.36 0.00 0.00 0.00 0.00 0.00 0.95 0.82 0.00 0.00 0.00 0.00 0.00 0.50 0.36 0.00 0.00 0.00 0.05 0.05 0.27 0.05 0.00 0.00 0.00 0.00 0.09 0.36 0.00 0.00 0.00 0.00 0.00 0.09 1.04 0.05 0.00 0.00 0.00 0.05 0.00 0.36 0.41 0.00 0.00 0.05 0.09 0.00 0.23 0.05 0.00 0.00 0.00 0.00 0.00 0.14 0.00 0.00 0.00 0.05 0.05 0.18 0.23 4.36 2.13 0.00 0.00 0.18 0.23 4.36 2.13 0.00 0.00 6.95 TOT 3.54 2.54 2.27 2.68 5.18 4.86 5.00 8.31 8.17 8.45 6.40 5.81 8.99 11.40 10.81 5.59 100.00 0.77 3.04 3.86 48.55 32.65 8.40 2.72 100.00 Wind Direction by Stability N
SSW SW WSW W WNW NW NNW TOTAL 0.00 0.23 0.23 0.95 1.23 0.64 0.27 0.05 0.00 0.05 0.82 1.14 0.18 0.32 0.00 0.23 0.14 1.04 0.68 0.18 0.00 0.05 0.09 0.05 1.36 1.00 0.14 0.00 0.05 0.09 0.09 3.68 1.04 0.18 0.05 0.00 0.14 0.18 2.41 1.77 0.32 0.05 0.00 0.09 0.18 1.95 2.00 0:68 0.09 0.00 0.00 0.14 4.59 2.32 1.18 0.09 0.00 0.18 0.32 4.09 2.91 0.64 0.05 0.00 0.05 0.45 3.86 3.54 0.32 0.23 0.05 0.14 0.23 2.23 2.45 0.59 0.73 0.09 0.23 0.41 1.82 1.95 0.64 0.68 0.00 0.27 0.32 5.40 2.27 0.64 0.09 0.41 0.68 0.54 4.86 3.54 1.36 0.00 0.09 0.23 0.32 6.49 3.32 0.36 0.00 0.00 0.77 0.41 3.04 0.23 3.86 3.00 48.55 1.50 32.65 0.36 8.40 0.09 2.72
-STABILITY CLASSES-Extremely Unstable Moderately Unstable Slightly Unstable Neutral Slightly Stable Moderately Stable Extrerely Stable Wind Direction by Wind Speed N
NNE NE ENE E
WNW Rw NNW TOTAL
-WIND SPEED CLASSES-0.00 0.05 0.68 1.18 1.27 0.36 0.00 0.00 0.09 0.54 0.27 1.04 0.45 0.14 0.00 0.05 0.68 0.82 0.64 0.09 0.00 0.00 0.09 1.23 1.32 0.05 0.00 0.00 0.00 0.05 0.86 2.36 1.59 0.32 0.00 0.00 0.09 0.73 1.41 2.13 0.50 0.00 0.00 0.09 1.04 1.27 1.82 0.64 0.14 0.00 0.05 0.41 2.54 3.18 1.50 0.64 0.00 0.14 0.36 0.73 2.77 2.41 1.77 0.00 0.05 0.41 1.63 2.13 3.36 0.86 0.00 0.09 0.77 1.36 2.82 0.95 0.41 0.00 0.05 0.77 1.91 1.91 0.73 0.45 0.00 0.09 1.00 2.68' 2.59 1.45 1.18 0.00 0.09 0.82 1.95 5.04 2.68 0.82 0.00 0.18 0.91 2.09 4.72 2.50 0.41 0.00 0.05 1.04 1.73 2.00 0.64 0.14 0.00 1.27 12.26 25.25 35.69 18.57 6.95 CALM 3.5 mph 3.6 -
7.5 mph 7.6 - 12.5 mph 12.6 - 18.5 mph 18.6 - 24.5 mph
> 24.5 mph
Dresden Nuclear Station 35 ft. Wind Speed and Direction Jar~uary-0ece-ber.
2003 15OFt-35Ft Delta-T (F)
Number of Observations -
B681 Values are Percent Occurrence SPEED WIND DIRECTI(M CLASSES------------------
STABILITY CLASSES------
CLASS N
NNE NE ENE E
WM&J N6' NNW TOTAL EU MU SUN Ss MS ES TOTAL EU MU C SU A N ILSS MKS ES EU MU I SI
- N I 55 2 MS ES EU IMU 3 SU
- N 1 Ss 8 Fs ES 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.03 0.03 0.06 0.23 0.55 0.36 0.08 0.41 0.05 0.09 0.74 0.65 0.06 0.00 0.09 0.05 0.00 0.32 0.20 0.00 0.00 0.00 0.01 0.01C
- 0.
12 0.01C 01.01 0.0cc 0.00 (
0.00 I 0.00 I 0.00I 0.00 0.00 0.00 0.00 0.01 0.02 0.23 0.66 0.25 0.01 0.29 0.07 0.07 0.82 0.83 0.08 0.00 0.20 0.05 0.02 0.51 0.10 0.00 0.00 0.00 I0.00 I0.00 I 0.16 I0.01 0.00 I 0.00
).
00
- 0.
00
- 0.
00 D.00 0.00 0.00 0.00 0.01 0.01 0.02 0.17 0.46 0.09 0.01 0.59 0.21 0.17 1.36 1.62 0.09 0.01 0.54 0.07 0.09 0.99 0.38 0.00 0.00 0.01 0.0DC 0.02 0.32 0.12 0.01 0.01c 0.00 0.00 0.00 0.00 0.00 0.00, 0.00 0.01 0.01 0.00 0.09 0.23 0.13 0.02 0.61 0.14 0.12 0.84 1.42 0.02 0.00 0.15 0.05 0.06 0.52 0.23 0.00 0.00 0.00 I 0.00 I0.00
!0.01
!0.01 10.00 I0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.02 0.02 0.14 0.23 0.13 0.06 0.16 0.06 0.09 0.92 1.59 0.16 0.05 0.12
- 0.
08 0.03 0.92 0.59 0.02 0.00 0.02 0.01 0.00 0.09 0.06 0.00 0.00 0.00 0.00, 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01
- 0.
08 0.22 0.21 0.06 0.16 0.06 0.07 0.74 1.27 0.67 0.13 0.03 0.05 0.03 0.59 0.65 0.02 0.01 0.00 0.01 0.00 0.15 0.07 I0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.00 0.07 0.16 0.18 0.12 0.12 0.08
- 0.
08 0.36 0.66 0.56 0.06 0.08 0.07 0.01 0.44 0.48
- 0.
08 0.00 0.00 0.00 0.00 0.14
- 0.
08 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.02 0.01 0.00 0.14 0.30 0.47 0.12 0.08 0.05 0.08 0.53 1.05 0.58 0.05 0.06 0.12
- 0.
08 0.90 0.69 0.01 0.00 0.03 0.01 0.03 0.39 0.30 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.13 0.32 0.43 0.24 0.03 0.02 0.06 0.45 1.12 0.48 0.03 0.14 0.14 0.09 1.09 1.11 0.03 0.00 0.05 0.07 0.07 0.50 0.66 0.00 0.00 0.00I 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.00 0.01 0.14 0.30 0.30 0.22 0.06 0.05 0.05 0.39 0.97 0.54 0.10 0.32 0.13 0.13 0.97 0.98 0.06 0.00 0.21 0.14 0.08 0.68 0.37 0.00 0.00 0.00 0.00
- 0.
00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.14 0.31 0.28 0.38 0.06 0.06 0.08 0.44 0.93 0.60 0.29 0.20 0.02 0.09 0.65 0.56 0.15s 0.00 0.15 0.07 0.13 0.47 0.21 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.02 0.00 0.01 0.18 0.31 0.31 0.22 0.09 0.08
.0.10 0.67 0.60 0.22 0.02 0.39 0.17 0.12 0.47 0.43 0.03 0.00
- 0.
18 0.02 0.07 0.33 0.10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.00 0.00 0.17 0.45 0.29 0.15 0.10 0.12 0.10 0.93 1.41 0.30 0.01 0.24 0.12 0.22 1.00 1..19 0.02 0.00 0.20 0.02 0.02 0.53 0.14 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.00 0.16 0.56 0.32
- 0.
08 0.22 0.05 0.12 0.90 1.57 0.45 0.02 0.66 0.18 0.15 1.17 1.11 0.00 0.00 0.30 0.07 0.12 0.59 0.32 0.00 0.01 0.00I 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.02 0.02 0.26 0.60 0.50 0.36 0.17 0.10 0.16 0.77 1.31
- 0.
13 0.02 0.36 0.24 0.07 1.14 0.93 0.01 0.00 0.10 0.01 0.02 0.23 0.02 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.02 0.02 0.01 0.36 0.69 0.51 0.30 0.52 0.10 0.02 0.85 1.06 0.07 0.01 0.23 0.07 0.14 0.82 0.66 0.00 0.00 0.01 0.01 0.03 0.21 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.15 0.15 0.17 0.18 2.70 6.38 4.75 2.42 3.67 3.67 1.28 1.46 11.70 18.04 5.01 0.81 3.80 3.80 1.59 1.34 12.50 10.47 0.45 0.01 1.27 1.27 0.45 0.60 4.93 2.48 0.00 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.17 0.18 2.70 6.38 4.75 2.42 16.75 1.28 1.46 11.70 18.04 5.01 0.81 41.98 1.59 1.34 12.50 10.47 0.45 0.01 30.16 0.45 0.60 4.93 2.48 0.00 0.01 9.73
Dresden Nuclear Station 35 ft. Wind Speed and Direction January-December.
2003 15OFt-35Ft Delta-T (F)
SPEED
WIND DIRECTION CLASSES ----------------------------------
CLASS N
SSW SW WSW W WN`WJ NW NNW TOTAL
.-------- STABILITY CLASSES ----------
EU MU SU N
2 SS 4 MS ES 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.07 0.07 0.00 0.00 0.00 0.01 0.01 0.14 0.09 0.00 0.00 0.01 0.02 0.01 0.15 0.15 0.00 0.00 0.07 0.05 0.01 0.08 0.02 0.00 0.00 0.01 0.00 0.00 0.02 0.05 0.00 0.00 0.00 0.01 0.01 0.08 0.01 0.00 0.00 0.00 0.00 0.00 0.06 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.09 0.09 0.09 0.05 0.60 0.40 0.00 0.00 0.09 0.05 0.60 0.40 0.00 0.00 1.23 EU G MU T SU N
2 SS 4 MS ES 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.08 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.14 0.01 0.00 0.00 0.00 0.00 0.00 0.14 0.01 0.00 0.00 0.15 TOT 4.12 4.39 7.38 4.67 5.56 5.28 3.86 6.43 7.52 7.53 6.49 5.33 7.90 9.20 7.59 6.74 100.00 8.99 3.58 3.63 32.57 37.78 10.21 3.25 100.00 Wind Direction by Stability N
NNE NE ENE E
SSW SW WSW W WNW NW NNT TOTAL 0.54 0.13 0.15 1.42 1.39 0.41 0.08 0.48 0.13 0.12 1.72 1.60 0.33 0.01 1.15 0.29 0.31 2.85 2.58 0.18 0.02 0.77 0.20 0.17 1.46 1.89 0.15 0.02 0.30 0.17 0.14 2.07 2.47 0.31 0.10 0.20 0.12 0.12 1.56 2.20 0.90 0.20 0.20 0.16 0.09 1.00 1.41 0.83 0.17 0.20 0.18 0.20 2.03 2.60 1.06 0.16 0.22 0.24 0.23 2.30 3.31 0.94 0.28 0.61 0.33 0.28 2.33 2.76 0.90 0.32 0.47 0.20 0.31 1.77 2.04 1.03 0.67 0.70 0.28 0.30 1.76 1.49 0.56 0.24 0.55 0.26 0.36 2.76 3.19 0.61 0.16 1.17 0.31 0.38 2.89 3.56 0.77 0.12 0.63 0.38 0.28 2.41 2.88 0.63 0.38 0.78 0.21 0.21 2.23 2.42 0.58 0.31 8.99 3.58 3.63 32.57 37.78 10.21 3.25
-STABILITY CLASSES-Extremely Unstable Moderately Unstable Slightly Unstable Neutral Slightly Stable Moderately Stable Extremely Stable Wind Direction by Wind Speed N
NNE NE ENE E
SSW SW WSW W WNW NW NNW TOTAL 0.00 1.35 1.99 0.66 0.13 0.00 0.00 0.00 1.19 2.15 0.88 0.17 0.00 0.00 0.00 0.78 4.05 2.07 0.47 0.00 0.00 0.00 0.50 3.14 1.00 0.02 0.00 0.00 0.00 0.59 3.03 1.76 0.18 0.00 0.00 0.00 0.58 3.09 1.38 0.23 0.00 0.00 0.00 0.56 1.91 1.16 0.22 0.00 0.00 0.00 1.06 2.41 2.05 0.77 0.14 0.00 0.00 1.12 2.20 2.60 1.34 0.25 0.01 0.00 0.98 2.15 2.58 1.47 0.35 0.00 0.00 1.11 2.45 1.67 1.03 0.23 0.00 0.00 1.06 1.79 1.61 0.71 0.08 0.08 0.00 1.07 2.97 2.79 0.91 0.12 0.05 0.00 1.14 3.32 3.27 1.41 0.06 0.01 0.00 1.76 2.67 2.75 0.39 0.01 0.00 0.00 1.91 2.64 1.91 0.28 0.00 0.00 0.00 16.75 41.98 30.16 9.73 1.23 0.15
-WIND SPEED CLASSES-CALM 3.5 rph 3.6 -
7.5 tnph 7.6 - 12.5 mph 12.6 - 1B.5 mph 18.6 - 24.5 mph
> 24.5 mph
Dresden Nuclear Station 300 ft. Wind Speed and Direction January-December.
2003 300Ft-35Ft Oelta-T (F)
Nuiber of Observations -
8740 Values are Percent Occurrence SPEED --------------------
WIND DIRECTION CLASSES ----------------------------------
CLASS N
NNE NE ENE E
STA3ILITY CLASSES ----------
EU MU SU N
55 MS ES TOTAL EU MU C SU A N L SS PM S ES 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.CO 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00.0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 EU MU I SU N
3 SS MS ES 0.00 0.00 0.00 0.06 0.03 0.01 0.00 0.00 0.00 0.01 0.07 0.01 0.00 0.00 0.00 0.00 0.00 0.01 0.06 0.02 0.00 0.00 0.00 0.00 0.07 0.09 0.06 0.00 0.00 0.00 0.01 0.05 0.07 0.03 0.00 0.00 0.00 0.00 0.03 0.05 0.02 0.00 0.00 0.00 0.00 0.08 0.02 0.02 0.00 0.00 0.00 0.01 0.03 0.03 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.10 0.09 0.09 0.02 0.02 0.01 0.00 0.00 0.00 0.01 0.00 0.10 0.02 0.08 0.01 0.00 0.01 0.00 0.07 0.01 0.01 0.00 0.01 0.00 0.00 0.06 0.03 0.05 0.00 0.00 0.00 0.00 0.07 0.02 0.03 0.00 0.00 0.00 0.00 0.07 0.06 0.01 0.01 0.00 0.00 0.02 0.07 0.02 0.00 0.00 0.01 0.01 0.02 0.06 1.03 0.65 0.39 0.02 0.02 0.06 1.03 0.65 0.39 0.02 2.19 EU HJ 4 SU
1 SS 8MS ES 0.00 0.01 0.07 0.03 0.07 0.11 0.43 0.33 0.08 0.13 0.11 0.08 0.01 0.01 0.08 0.05 0.10 0.07 0.17 0.08 0.58 0.82 0.47 0.45 0.10 0.18 0.02 0.01 0.07 0.10 0.03 0.07 0.09 0.10 0.59 0.74 0.59 0.76 0.26 0.16 0.07 0.08 0.01 0.10 0.07 0.40 0.21 0.03 0.03 0.11 0.16 0.18 1.27 0.98 0.21 0.05 0.15 0.16 0.13 1.09 0.62 0.17 0.03 0.06 0.09 0.27 0.80 0.66 0.14 0.01 0.06 0.26 0.24 1.77 0.92 0.05 0.00 0.01 0.00 0.00 0.58 0.02 0.00 0.00 0.01 0.01 0.05 0.02 0.07 0.09 0.54 0.30 0.31 0.14 0.08 0.11 0.02 0.02 0.03 0.00 0.07 0.10 0.22 0.07 0.97 0.54 0.53 0.45 0.09 0.08 0.02 0.00 0.02 0.00 0.07 0.00 0.07 0.00 1.02 0.57 0.49 0.58 0.05 0.17 0.00 0.00 0.00 0.05 0.14 0.54 0.35 0.06 0.01 0.00 0.07 0.09 0.47 0.61 0.29 0.00 0.00 0.00 0.06 0.37 0.82 0.46 0.03 0.00 0.05 0.05 0.33 0.18 0.09 0.02 0.01 0.02 0.14 0.66 0.63 0.40 0.07 0.00 0.02 0.10 0.92 0.53 0.49 0.05 0.00 0.00 0.01 0.30 0.15 0.09 0.01 0.00 0.01 0.08 0.65 0.53 0.31 0.00 0.00 0.06 0.11 1.14 1.03 0.27 0.06 0.00 0.01 0.07 0.22 0.18 0.06 0.00 0.03 0.07 0.10 0.71 0.66 0.21 0.06 0.02 0.15 0.32 0.93 1.02 0.48 0.08 0.00 0.01 0.03 0.30 0.23 0.19 0.00 0.01 0.02 0.09 0.38 0.43 0.29 0.16 0.02 0.07 0.14 0.89 1.04 0.38 0.13 0.00 0.03 0.07 0.43 0.27 0.10 0.07 0.01 0.08 0.17 0.55 0.42 0.33 0.10 0.09 0.11 0.16 0.59 0.59 0.31 0.13 0.00 0.03 0.02 0.57 0.31 0.16 0.05 0.01 0.07 0.13 0.96 0.63 0.24 0.11 0.02 0.08 0.11 0.96 0.84 0.24 0.02 0.00 0.02 0.07 0.41 0.22 0.09 0.00 0.02 0.17 0.23 0.76 0.48 0.18 0.02 0.14 0.18 0.25 1.42 1.21 0.38 0.00 0.00 0.02 0.00 0.10 0.08 0.17 0.42 0.45 0.17 0.17 0.13 0.10 0.00 0.01 0.01 0.05 0.11 0.16 0.14 0.10 0.73 0.77 0.55 0.27 0.15 0.08 0.01 0.03 0.01 0.03 0.06 0.08 0.23 0.07 1.40 1.16 1.21 0.82 0.27 0.06 0.02 0.02 0.13 0.13 0.68 1.40 6.77 3.76 1.64 0.29 0.49 0.49 1.56 2.23 12.60 9.00 3.1B 0.68 0.70 0.70 1.14 1.95 14.37 12.19 4.15 0.72 0.68 1.40 6.77 3.76 1.64 0.29 14.66 1.56 2.23 12.60 9.00 3.18 0.68 29.74 1.14 1.95 14.37 12.19 4.15 0.72 35.22
Dresden Nuclear Station 300 ft. Wind Speed and Direction January-December.
2003 300Ft-35Ft Delta-T (F)
SPEED WIND DIRECTION CLASSES ----------------------------------
CLASS N
STABILITY CLASSES ----------
EU MU SU N
2 SS 4FIS ES 0.00 0.00 0.00 0.24 0.09 0.03 0.00 0.06 0.02 0.02 0.37 0.11 0.01 0.01 0.03 0.03 0.01 0.58 0.01 0.01 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.00 0.00 0.00 0.00 0.01 0.32 0.08 0.00 0.00 0.00 0.00 0.00 0.02 0.00 0.00 0.00 0.00 0.00 0.00 0.27 0.18 0.02 0.00 0.00 0.00 0.00 0.03 0.00 0.00 0.00 0.00 0.00 0.00 0.21 0.11 0.08 0.01 0.00 0.00 0.00 0.05 0.01 0.00 0.00 0.00 0.02 0.05 0.42 0.19 0.02 0.00 0.00 0.00 0.02 0.09 0.10 0.00 0.00 0.00 0.01 0.05 0.51 0.62 0.24 0.00 0.00 0.00 0.00 0.30 0.43 0.00 0.00 0.00 0.05 0.10 0.58 0.85 0.10 0.03 0.01 0.00 0.03 0.30 0.24 0.00 0.00 0.01 0.03 0.09 0.55 0.33 0.14 0.03 0.00 0.03 0.08 0.18 0.06 0.00 0.00 0.02 0.09 0.09 0.42 0.23 0.01 0.00 0.00 0.03 0.02 0.29 0.02 0.00 0.00 0.02 0.06 0.05 0.55 0.31 0.01 0.00 0.00 0.01 0.03 0.41 0.13 0.01 0.00 0.15 0.11 0.06 0.98 0.69 0.09 0.00 0.02 0.08 0.05 0.3B 0.14 0.00 0.00 0.06 0.05 0.02 0.78 0.30 0.05 0.01 0.01 0.02 0.01 0.15 0.01 0.00 0.00 0.03 0.02 0.05 0.41 0.22 0.02 0.00 0.01 0.00 0.00 0.06 0.00 0.00 0.00 0.39 0.39 0.50 0.59 7.25 4.32 0.85 0.10 0.06 0.06 0.18 0.27 2.49 1.17 0.01 0.00 0.50 0.59 7.25 4.32 0.85 0.10 14.02 EU G MU T SU N
2 SS 4 MS ES 0.00 0.00 0.00 0.06 0.01 0.00 0.00 0.00 0.00 0.02 0.14 0.00 0.00 0.00 0.18 0.27 2.49 1.17 0.01 0.00 4.19 TOT 4.57 5.24 6.99 6.22 5.32 3.88 5.00 5.77 7.20 7.80 6.59 5.98 7.31 9.13 7.32 5.68 100.00 1.77 4.08 6.50 44.52 31.10 10.22 1.81 100.00 Wind Direction by Stability N
SSW SW WSW W WN4 NW NNh' TOTAL 0.15 0.21 0.33 1.97 1.28 0.53 0.10 0.22 0.19 0.35 2.47 1.45 0.43 0.11 0.31 0.46 0.39 3.40 1.88 0.45 0.11 0.13 0.35 0.51 3.27 1.70 0.24 0.01 0.07 0.18 0.38 2.92 1.48 0.25 0.05 0.01 0.13 0.16 1.75 1.40 0.41 0.02 0.00 0.11 0.29 1.70 1.93 0.90 0.06 0.01 0.11 0.37 2.46 1.67 1.01 0.14 0.00 0.08 0.25 3.01 2.85 0.94 0.07 0.07 0.27 0.63 2.83 2.97 0.86 0.17 0.05 0.18 0.43 2.40 2.12 1.08 0.33 0.13 0.37 0.51 2.36 1.56 0.77 0.30 0.07 0.25 0.34 3.51 2.24 0.71 0.18 0.33 0.57 0.65 4.02 2.76 0.78 0.02 0.09 0.24 0.48 3.55 2.30 0.61 0.06 0.15 0.37 0.41 2.91 1.51 0.26 0.07 1.77 4.08 6.50 44.52 31.10 10.22 1.81
-STABILITY CLASSES-Extremely Unstable Moderately Unstable Slightly Unstable Neutral Slightly Stable Moderately Stable Extremely Stable Wind Direction by Wind Speed N
SSW SW WSW W WNW NW NNW TOTAL 0.00 0.10 0.78 1.53 1.72 0.37 0.07 0.00 0.09 0.71 1.66 2.01 0.61 0.16 0.00 0.09 0.86 2.96 2.35 0.69 0.05 0.00 0.22 2.04 3.30 0.62 0.05 0.01 0.00 0.16 1.08 1.93 1.72 0.41 0.02 0.00 0.10 0.70 1.24 1.33 0.48 0.03 0.00 0.13 1.14 1.52 1.74 0.41 0.06 0.00 0.08 0.72 1.93 2.11 0.71 0.22 0.00 0.22 0.56 1.58 2.68 1.43 0.73 0.00 0.13 0.54 1.84 3.00 1.72 0.58 0.00 0.23 0.77 1.38 2.67 1.19 0.35 0.00 0.10 0.98 1.67 1.99 0.87 0.37 0.00 0.15 1.14 2.15 2.28 1.00 0.59 0.00 0.13 0.81 1.86 3.58 2.08 0.66 0.00 0.15 0.80 1.70 3.20 1.26 0.21 0.00 0.11 1.03 1.46 2.24 0.76 0.07 0.00 2.19 14.66 29.74 35.22 14.02 4.19
-WINO SPEED CLASSES-CALM
< 3.5 rph 3.6 -
7.5 nph 7.6 - 12.5 nfh 12.6 - 18.5 mph 18.6 - 24.5 mph
> 24.5 mph