Definitions 1.1 1.1 Definitions (continued)

CHANNEL OPERATIONAL A COT shall be the injection of a simulated or actual signal TEST (COT) into the channel as close to the sensor as practicable to verify OPERABILITY of all devices in the channel required for channel OPERABILITY. The COT shall include adjustments, as necessary, of the required alarm, interlock, and trip setpoints required for channel OPERABILITY such that the setpoints are within the necessary range and accuracy. The COT may be performed by means of any series of sequential, overlapping, or total channel steps.

CORE ALTERATION CORE ALTERATION shall be the movement of any fuel, sources, or reactivity control components, within the reactor vessel with the vessel head removed and fuel in the vessel.

Suspension of CORE ALTERATIONS shall not preclude completion of movement of a component to a safe position.

CORE OPERATING LIMITS The COLR is the unit specific document that provides cycle REPORT (COLR) specific parameter limits for the current reload cycle. These cycle specific parameter limits shall be determined for each reload cycle in accordance with Specification 5.6.5. Plant operation within these limits is addressed in individual Specifications.

DOSE EQUIVALENT 1-131 DOSE EQUIVALENT 1-131 shall be that concentration of 1-131 (microcuries/gram) that alone would produce the same thyroid dose as the quantity and isotopic mixture of 1-1 31, 1-132, 1-133,1-134, and 1-135 actually present. The thyroid dose conversion factors used for this calculation shall be those listed in Table IlIl of TID-14844, AEC, 1962, "Calculation of Distance Factors for Power and Test Reactor Sites" or those derived from the data provided in International Commission on Radiological Protection Publication 30, "Limits for Intakes of Radionuclides by Workers," 1979.

E -AVERAGE E shall be the average (weighted in proportion to the DISINTEGRATION ENERGY concentration of each radionuclide in the reactor coolant at the time of sampling) of the sum of the average beta and gamma energies per disintegration (in MeV) for isotopes, other than iodines, with half lives > 15 minutes, making up at least 95% of the total noniodine activity in the coolant.

(continued)

CALLAWAY PLANT 1.1-2 Amendment No. 159

MFIVs 3.7.3 SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.7.3.1 ------------ I------- --- NOTE--------a----

Only required to be performed in MODES 1 and 2.

Verify the closure time of each MFIV is < 15 seconds. In accordance with I the Inservice Testing Program SR 3.7.3.2 ------------------ NOTE ---------------

Only required to be performed in MODES 1 and 2.

Verify each MFIV actuates to the isolation position on 18 months an actual or simulated actuation signal.

CALLAWAY PLANT 3.7-8 Amendment No. 159