December 16, 2003 LICENSEE:

FirstEnergy Nuclear Operating Company FACILITY:

Davis-Besse Nuclear Power Station, Unit 1

SUBJECT:

SUMMARY

OF MEETING ON JUNE 19, 2003, TO DISCUSS THE LICENSEES MODIFICATIONS TO THE HIGH PRESSURE INJECTION PUMPS On June 19, 2003, members of the U.S. Nuclear Regulatory Commission (NRC) staff met with FirstEnergy Nuclear Operating Company (the licensee), representatives at NRC Headquarters, Two White Flint North, 11545 Rockville Pike, Rockville, MD. The meeting was also video-conferenced with NRC staff at Region III. The purpose of the meeting was to discuss the licensees planned modifications to the Davis-Besse high pressure injection (HPI) pumps to address the issue of possible debris clogging of a cooling port to the hydrostatic bearing. The meeting was a Category 1 public meeting with an audioconference bridge available for those unable to attend in person. The licensees presentation slides are available on the NRC Web site for the meeting. Enclosure 1 is a list of attendees.

The licensees presentation included background information on the HPI pumps, planned modifications to the pumps, and testing planned for the pump modification design. The licensee mentioned that the French had moved the supply port as they were contemplating doing, and that the licensee was trying to obtain information regarding the French pump design and modification. The licensee stated that the first critical operating speed of their pumps was at 3900 rpm and that at a clearance of 2X, the critical operating speed reduced to 3300 rpm.

The licensees contractor was performing analyses concerning the above as the pumps operating speed is 3600 rpm. The licensee stated that the hydraulic performance model would be validated by tests in the plant. The mockup tests are to be performed at Wylie laboratory in Huntsville, Alabama. The licensee expects to complete the self-flushing and clearance tests within the week.

In response to a staff question, the licensee stated that a Failure Modes and Effects Analysis will be available for NRC staff review. In response to another staff question, the licensee stated that the internal strainer would be constructed of austenitic stainless steel and if the strainer were to be destroyed, the debris would flow through the pump. The meeting ended with the staff stating that it would continue to follow the licensees modification design.

/RA/

Jon B. Hopkins, Senior Project Manager, Section 2 Project Directorate III Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-346

Enclosures:

1. Attendance List
2. Meeting Slides cc w/encls: See next page December 16, 2003 In response to a staff question, the licensee stated that a Failure Modes and Effects Analysis will be available for NRC staff review. In response to another staff question, the licensee stated that the internal strainer would be constructed of austenitic stainless steel and if the strainer were to be destroyed, the debris would flow through the pump. The meeting ended with the staff stating that it would continue to follow the licensees modification design.

/RA/

Jon B. Hopkins, Senior Project Manager, Section 2 Project Directorate III Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-346

Enclosures:

1. Attendance List
2. Meeting Slides cc w/encls: See next page DISTRIBUTION:

PUBLIC LMarsh/ELeeds JGolla PDIII-2 Reading WRuland AMendiola HNieh JHopkins TScarbrough THarris SUnikewicz OGC AFranovich ACRS/ACNW DTerao CLipa, RIII BJain Package: ML033450367 Attachment - Slides: ML033450382 ADAMS Accession Number: ML033450292 OFFICE PDIII-2/PM PDIII-2/LA PDIII-1/SC NAME JHopkins THarris AMendiola DATE 12/12/03 12/12/03 12/16/03 OFFICIAL RECORD COPY

ATTENDANCE LIST NRC MEETING WITH FIRSTENERGY NUCLEAR OPERATING COMPANY DAVIS-BESSE HPI PUMP MODIFICATIONS JUNE 19, 2003 J. Powers, FENOC R. Coward, MPR Associates R. Schrauder, FENOC G. Leidich, FENOC S. Kinsey, MPR Associates S. Frantz, Morgan Lewis A. Mendiola, NRC H. Nieh, NRC W. Ruland, NRC T. Scarbrough, NRC S. Unikewicz, NRC J. Hopkins, NRC R. Franovich, NRC D. Terao, NRC W. Lyon, NRC D. Lochbaum, UCS D. Horner, McGraw-Hill M. Woods, Pittsburgh Post Gazette D. Raleigh, Scientech B. Jain, NRC J. Golla, NRC T. Janosi, Hungarian AEA F. Adovjaih, Hungarian AEA

Davis-Besse Nuclear Power Station, Unit 1 cc:

Mary E. OReilly FirstEnergy Corporation 76 South Main St.

Akron, OH 44308 Manager - Regulatory Affairs FirstEnergy Nuclear Operating Company Davis-Besse Nuclear Power Station 5501 North State - Route 2 Oak Harbor, OH 43449-9760 Director, Ohio Department of Commerce Division of Industrial Compliance Bureau of Operations & Maintenance 6606 Tussing Road P.O. Box 4009 Reynoldsburg, OH 43068-9009 Regional Administrator U.S. Nuclear Regulatory Commission 801 Warrenville Road Lisle, IL 60523-4351 Michael A. Schoppman Framatome ANP 1911 N. Ft. Myer Drive Rosslyn, VA 22209 Resident Inspector U.S. Nuclear Regulatory Commission 5503 North State Route 2 Oak Harbor, OH 43449-9760 Randel J. Fast, Plant Manager FirstEnergy Nuclear Operating Company Davis-Besse Nuclear Power Station 5501 North State - Route 2 Oak Harbor, OH 43449-9760 Dennis Clum Radiological Assistance Section Supervisor Bureau of Radiation Protection Ohio Department of Health P.O. Box 118 Columbus, OH 43266-0118 Carol OClaire, Chief, Radiological Branch Ohio Emergency Management Agency 2855 West Dublin Granville Road Columbus, OH 43235-2206 Zack A. Clayton DERR Ohio Environmental Protection Agency P.O. Box 1049 Columbus, OH 43266-0149 State of Ohio Public Utilities Commission 180 East Broad Street Columbus, OH 43266-0573 Attorney General Department of Attorney General 30 East Broad Street Columbus, OH 43216 President, Board of County Commissioners of Ottawa County Port Clinton, OH 43252 President, Board of County Commissioners of Lucas County One Government Center, Suite 800 Toledo, OH 43604-6506 David Lochbaum, Nuclear Safety Engineer Union of Concerned Scientists 1707 H Street NW, Suite 600 Washington, DC 20006 The Honorable Dennis J. Kucinich United States House of Representatives Washington, D.C. 20515 The Honorable Dennis J. Kucinich, Member United States House of Representatives 14400 Detroit Avenue Lakewood, OH 44107 Mr. James P. Riccio Nuclear Policy Analyst Greenpeace 702 H. Street, NW, Suite 300 Washington, DC 20001 Paul Gunter Director Nuclear Watchdog Project Nuclear Information & Resource Service 1424 16th Street NW Suite 401 Washington, DC 20009