1~~Entergy Entergy Nuclear Northeast Indian Point Energy Center 295 Broadway, Suite 1 PO Box 249 Buchanan, NY 10511-0249 Tel 9147345340 Fax 914 734 5718 Fred Dacimo Vice President, Operations May 1, 2003 Re: Indian Point Unit Nos. 1 and 2 Docket Nos. 50-3 and 50-247 NL-03-068 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Mail Stop O-P1-17 Washington, D.C.

20555-0001

Subject:

Annual Effluent and Waste Disposal Report

Dear Sir:

I Attached is the 2002 Annual Effluent and Waste Disposal Report for Entergy Nuclear Operation, Inc.'s (ENO's) Indian Point Unit Nos. 1 and 2.

No new regulatory commitments are being made by ENO in this correspondence.

Should you have any questions regarding this matter, please contact Mr. John McCann, Licensing Manager at (914) 734-5074.

Sincerely, Fred R. Dacimo Vice President, Operations Indian Point Energy Center Attachments

cc:

Mr. Hubert J. Miller Regional Administrator -

Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Mr. Patrick D. Milano, Senior Project Manager Project Directorate I-1 Division of Licensing Project Management Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Mail Stop O-8-C2 Washington, D.C.

20555 Senior Resident Inspector U.S. Nuclear Regulatory Commission P.O. Box 38 Buchanan, NY 10511 Attn. Chief, Compliance Section New York State DEC Division of Water 50 Wolf Road Albany, NY 12233 Attn. Regional Water Engineer New York State DEC 200 White Plains Road White Plains, NY 10601

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 ANNUAL EFFLUENT AND WASTE DISPOSAL REPORT 2002 ENTERGY NUCLEAR OPERATIONS, INC.

INDIAN POINT UNIT NOS. 1 & 2 DOCKET NOS. 50-03 & 50-247 MAY 2003

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 ANNUAL EFFLUENT AND WASTE DISPOSAL REPORT 2002 FACILITY:

Indian Point Station (Units 1 and 2)

LICENSEE:

Entergy Nuclear Operations, Inc.

This information is provided pursuant to 10 CFR 50.36a(a)(2) and employs certain guidance as set forth in Regulatory Guide 1.21, Revision 1. The numbered sections of this part of the report reference corresponding sections of the subject Regulatory Guide, pages 1.21-10 through 1.21-12.

This Annual Effluent and Waste Disposal Report for Indian Point Units 1 and 2 covers discharges for 2002.

Entergy Nuclear Operations, Inc., the licensee for Indian Point Unit 3, will also issue a report for the Indian Point Unit No. 3 facility, separately.

A.

Supplemental Information and Definition

1.

Regulatory Limits Indian Point Units 1 and 2 are presently subject to radioactive waste release specifications that are set forth in Appendix A to Facility Operating Licenses DPR-5 and DPR-26, entitled "Technical Specifications and Bases" (Indian Point Unit No. 2 Technical Specification Section 3.9 "Radioactive Effluents").

2.

Maximum Permissible Concentrations (MPC)

Gaseous Effluents Concentrations of gaseous discharges in unrestricted areas are computed by producing release rate (Q) and the annual average dispersion factor (X/Q) at the most restrictive site boundary location.

The mixture percent of MPC* is obtained by adding the effects of each nuclide; the effect of each nuclide is, in turn, the quotient of its computed concentration and its MPC.

10 CFR 20 Appendix B Table 2 Col 1 (Pre-1994).

A-1

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 Liquid Effluents All liquid discharges from Indian Point are made through a common discharge canal with a minimum of 100,000 gpm dilution water.

The isotopic content, excluding tritium and dissolved noble gas, of continuous and batch mode discharges of liquid effluent for each calendar quarter has been added and a weighted average fraction of MPC*

has been calculated for this isotopic mixture.

The percent of the applicable limit reported in Section C of this document is the percent of MPC concentration of the time-average diluted concentration for each quarter.

The tritium limit has been established in the same manner as the limits for other isotopes in liquid effluents. A derived MPC of 2x10-4 uCi/ml for dissolved noble gases has been conservatively adopted for liquid effluents due to the swimming pathway.

10 CFR 20 Appendix B Table 2 Col 2 (Pre-1994).

3.

Average Energy The average energy (E)* of the radionuclide mixture in releases of fission and activation gases for the four quarters in 2002 are provided below:

1st 2nd 3rd 4th Quarter Quarter Quarter Quarter Beta 0.054 0.050 0.081 0.157 Gamma 0.000 0.000 0.011 0.034

  • Values in MeV/Dis.
4.

Measurements and Approximations of Total Radioactivity

a.

Fission and Activation Gases Analysis of effluent gases was performed in compliance with the requirements of Table 4.10-3 of the Technical Specifications.

In the case of isolated tanks (batch releases), the total activity discharged was based on an isotopic analysis of each batch and the volume of gas in that batch.

Vapor Containment ventilation discharges have generally been treated as batch releases.

At least one complete isotopic concentration analysis of A-2

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 containment air was performed per week.

This was applied to gross analysis of the ventilation air performed prior to each discharge.

This information was combined with the volume of air in each discharge to calculate the radionuclide composition of these discharges.

The continuous discharges were based on the isotopic content determined from weekly samples of ventilation air.

This information was combined with total air volume discharged by this route.

The accumulation of batch and containment ventilation releases was then used to determine total discharges.

Iodines and Particulates Iodine-131 and particulate releases are quantified by collecting a continuous sample of ventilation air on a potassium-iodide impregnated activated charcoal cartridge and a glass-fiber filter paper.

These samples are obtained as required by Table 4.10-3 of the Technical Specifications.

The concentration of isotopes found by analysis of these samples was combined with the volume of air discharged during the sampling period to calculate the amount of activity discharged.

For other iodine isotopes the ratio of each isotope to iodine-131 was determined by a monthly 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> composite sample.

This ensures the proper identification of the short-lived I-133 and I-135 isotopes.

d.

Liquid Effluents A sample of each batch discharge was taken and an isotopic analysis was performed in compliance with the requirements specified in Table 4.10-1 of the Technical Specifications.

This isotopic concentration data was combined with information of volume discharged to determine the amount of each isotope discharged in the period.

Samples of continuous discharges have been taken and analyzed in compliance with Table 4.10-1 of the Technical Specifications.

This concentration data was combined with the volume discharged to calculate the amount of each isotope discharged.

A-3

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 The above concentrations were used in conjunction with the actual dilution flow to calculate the fraction of maximum permissible concentration.

e.

Error Estimates The total error estimate is the geometric sum of counting uncertainty and sampling uncertainty, expressed as a percent.

Sampling uncertainties are considered independent of activity level and largely fixed in value.

However, counting uncertainties are activity level dependent.

The percent counting uncertainty is the quotient of the 1 sigma (Poisson) uncertainty and the activity measured.

This percent uncertainty is maximized at low activity levels, specifically at the lower limit of detection (LLD).

It can be shown that the percent uncertainty at LLD is no more than 35%.

But as most positive samples are detected at several multiples of LLD, at least, the percent uncertainty is more likely to be in the 8% to 12% range.

Adding a consideration of fixed uncertainty of sampling, the total uncertainty is estimated to be 15%.

A-4

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 2nd 3 rd 4th

5.

Batch Releases:

a.

Liquid Number of Batch Releases Total Time Period of Batch Releases (Minutes)

Maximum Time Period of Batch Release (Minutes)

Average Time Period of Batch Release (Minutes)

Minimum Time Period of Batch Release (Minutes)

Average Stream Flow (cfs) 2000 2001 2002 1st Qtr.

Qtr.

Qtr.

Qtr.

20 5,090 37 7,360 26 6,310 53 16,600 580 695 575 1,390 255 199 243 78 20 80 5,433 1,942 6,886 7,062 5,944 7,710 2nd Qtr.

123 1,972 8,475 7,592 3rd Qtr.

118 314 48 3,402 7,651 4, 785 4th Qtr.

77

b.

Gaseous Number of Batch Releases Total Time Period of Batch Releases (Minutes)

Maximum Time Period of Batch Release (Minutes)

Average Time Period of Batch Release (Minutes)

Minimum Time Period of Batch Release (Minutes)

6.

Abnormal Releases 1st Qtr.

143 148,000 148,000 149,000 40,000 130,000 131,000 132,000 32,200 1,040 1,200 1,260 520 1

3 8

2 a.

b.

Liquid -

None Gaseous -

None A-5

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 ANNUAL EFFLUENT AND WASTE DISPOSAL REPORT B -

GASEOUS EFFLUENTS 2002 ENTERGY NUCLEAR OPERATIONS, INC.

INDIAN POINT UNIT NOS. 1 & 2 DOCKET NOS. 50-03 & 50-247 MAY 2003

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 2002 EFFLUENT AND WASTE DISPOSAL GASEOUS EFFLUENTS --

SUMMATION OF ALL RELEASES UNITS QUARTER QUARTER

EST.

TOTAL:

1 2

ERROR, A. FISSION AND ACTIVATION GASES
1. TOTAL RELEASE
Ci
9.25E+00 : 3.33E+00 : 1.50E+01 :
2. AVERAGE RELEASE
uCi/SEC:

1.19E+00 4.23E-01 RATE FOR PERIOD

3. PERCENT OF TECHNICAL:
1.71E-03 : 4.71E-04 SPECIFICATION LIMIT :

B. IODINES

1. TOTAL IODINE-131
Ci
2.51E-04 : 2.55E-04 : 1.50E+01 :
2. AVERAGE RELEASE
uCi/SEC:

3.23E-05 : 3.24E-05 RATE FOR PERIOD

3. PERCENT OF TECHNICAL:
1.59E-04 : 1.59E-04 SPECIFICATION LIMIT :

C. PARTICULATES

1. PARTICULATES WITH
Ci
1.46E-03 : 7.18E-04 : 1.50E+01 HALF-LIVES >8 DAYS
2. AVERAGE RELEASE
uCi/SEC:

1.87E-04 : 9.13E-05 RATE FOR PERIOD

3. PERCENT OF TECHNICAL:
1.45E-06 : 2.19E-06 SPECIFICATION LIMIT :
4. GROSS ALPHA
Ci
2.10E-07 : 2.64E-07 RADIOACTIVITY D. TRITIUM
1. TOTAL RELEASE
Ci
2.50E+02 : 2.54E+02 : 1.50E+01 :
2. AVERAGE RELEASE
uCi/SEC:

3.22E+01 : 3.23E+01 RATE FOR PERIOD

3. PERCENT OF TECHNICAL:

7.90E-02 : 7.92E-02 SPECIFICATION LIMIT :

B-1

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 EFFLUENT AND WASTE DISPOSAL 2002 ANNUAL REPORT GASEOUS EFFLUENTS --

SUMMATION OF ALL RELEASES CONTINUOUS MODE BATCH MODE

NUCLIDES UNITS QUARTER QUARTER QUARTER QUARTER
RELEASED 1

2 1

2

1. FISSION AND ACTIVATION GASES
H3
Ci
2.50E+02 :

2.54E+02 : 0.OOE+00 : 0.OOE+00 :

C14
Ci
2.OOE+O0 : 2.OOE+00 :

0.OOE+00 : 0.OOE+00 :

AR41 Ci
1.07E-08 :

6.OOE-05 :

2.89E-02 :

3.45E-02 :

KR85M
Ci
1.07E-08 :

5.18E-05 :

1.58E-03 : 6.43E-04 :

KR85
Ci
0.OOE+00 :

0.OOE+00 : 5.74E+00 :

3.20E-03 :

KR87
Ci
0.OOE+00 :

2.86E-05 : 5.17E-04 : 1.79E-04 :

KR88
Ci
0.OOE+00 :

6.19E-05 : 1.80E-03 : 6.94E-04 :

XE131M
Ci
0.OOE+00 :

0.OOE+00 : 5.48E-05 : O.OOE+00 :

XE133M
Ci
0.OOE+00 : 0.OOE+00 :

6.28E-03 :

4.47E-04 :

XE133
Ci
1.84E-03 : 4.55E-03 : 1.45E+00 : 1.27E+00 :
XE135M Ci
0.OOE+00 :

1.30E-05 :

2.50E-04 : 1.02E-04 :

XE135
Ci
8.93E-04 : 1.60E-03 : 1.98E-02 : 9.14E-03 :
XE138
Ci 0.OOE+00 : 0.OOE+00 : 7.46E-05 :

4.85E-05 :

TOTAL FOR :
PERIOD
Ci 2.52E+02 2.56E+02 7.25E+00 :

1.32E+00 (ABOVE)

CONTINUOUS MODE BATCH MODE

NUCLIDES
UNITS :

QUARTER QUARTER QUARTER QUARTER

RELEASED 1

2 1

2

2. IODINES
I131
Ci
2.51E-04 : 2.55E-04 0.OOE+00 0.OOE+00 :
TOTAL FOR:
PERIOD
Ci 2.51E-04 2.55E-04 0.OOE+00 :

0.OOE+00 (ABOVE)

B-2

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 EFFLUENT AND WASTE DISPOSAL 2002 ANNUAL REPORT GASEOUS EFFLUENTS --

SUMMATION OF ALL RELEASES CONTINUOUS MODE BATCH MODE

NUCLIDES
UNITS QUARTER QUARTER QUARTER QUARTER
RELEASED 1

2 1

2

3. PARTICULATES
C060
Ci
1.78E-06 : 3.65E-07 0.OOE+00 0.OOE+00 :
SR89
Ci
0.OOE+00 : 4.13E-07 0.OOE+00 0.OOE+00 :
CS134
Ci
4.05E-06 0.OOE+00 0.OOE+00 0.OOE+00 :
CS137
Ci
3.47E-06 : 1.63E-05 0.OOE+00 0.OOE+00 :
  • NI63
Ci
7.96E-08 : 3.60E-07 : 0.OOE+00 : 0.OOE+00 :
  • NB95
Ci
3.69E-06 : 0.OOE+00 : 0.OOE+00 : 0.OOE+00 :
  • RB88
Ci
0.OOE+00 0.OOE+00 : 1.44E-03 : 7.01E-04 :
  • BA133
Ci
1.25E-06 : 0.OOE+00 : 0.OOE+00 : 0.OOE+00 :
TOTAL FOR:
PERIOD
Ci 1.43E-05 1.74E-05 1.44E-03 7.01E-04 (ABOVE)

DENOTES SUPPLEMENTAL ISOTOPES B-3

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 EFFLUENT AND WASTE DISPOSAL 2002 ANNUAL REPORT GASEOUS EFFLUENTS --

SUMMATION OF ALL RELEASES UNITS QUARTER

QUARTER
EST.

TOTAL:

3 4

ERROR, A. FISSION AND ACTIVATION GASES
1. TOTAL RELEASE
Ci
1.07E+02 : 1.61E+03 : 1.50E+01 :
2. AVERAGE RELEASE
uCi/SEC:

1.34E+01:

2.02E+02 RATE FOR PERIOD

3. PERCENT OF TECHNICAL:
2.31E-02 : 3.32E-01 SPECIFICATION LIMIT :

B. IODINES

1. TOTAL IODINE-131
Ci
2.62E-04 : 2.88E-04 : 1.50E+01 :
2. AVERAGE RELEASE
uCi/SEC:

3.29E-05 3.63E-05 RATE FOR PERIOD

3. PERCENT OF TECHNICAL:
1.62E-04 : 1.78E-04 SPECIFICATION LIMIT :

C. PARTICULATES

1. PARTICULATES WITH
Ci
6.30E-04 : 8.46E-02 1.50E+01 HALF-LIVES >8 DAYS
2. AVERAGE RELEASE
uCi/SEC:

7.93E-05 : 1.06E-02 RATE FOR PERIOD

3. PERCENT OF TECHNICAL:
5.40E-06 : 2.39E-06 SPECIFICATION LIMIT :
4. GROSS ALPHA
Ci
2.41E-07 : 1.45E-07 RADIOACTIVITY D. TRITIUM
1. TOTAL RELEASE
Ci
2.70E+02 : 1.05E+02 : 1.50E+01 :
2. AVERAGE RELEASE
uCi/SEC:

3.40E+01 : 1.33E+01 RATE FOR PERIOD

3. PERCENT OF TECHNICAL:
8.35E-02 : 3.25E-02 SPECIFICATION LIMIT :

B4

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 EFFLUENT AND WASTE DISPOSAL 2002 ANNUAL REPORT GASEOUS EFFLUENTS --

SUMMATION OF ALL RELEASES CONTINUOUS MODE BATCH MODE

NUCLIDES
UNITS QUARTER QUARTER QUARTER QUARTER
RELEASED 3

4 3

4

1. FISSION AND ACTIVATION GASES
H3
Ci
2.70E+02 : 1.05E+02 0.OOE+00 0.OOE+00 :
C14
Ci
2.OOE+00 : 2.OOE+00 0.OOE+00 : 0.OOE+00 :
AR41
Ci
1.79E-04 : 3.70E-05 : 6.81E-02 : 1.63E-02 :
KR85M
Ci
6.54E-05 : 3.44E-06 : 1.64E-01 : 3.12E-02 :
KR85
Ci
O.OOE+00 : 3.50E+02 : 2.24E+01 : 4.50E+01 :
KR87
Ci
1.32E-05 : 1.78E-09 : 5.99E-03 : 2.71E-06 :
KR88
Ci
3.99E-05 : 1.28E-08 : 1.40E-01 : 8.44E-06 :
XE131M Ci
0.OOE+00 : O.OOE+00 : 4.65E-01 : 1.13E+00 :
XE133M
Ci
0.OOE+00 : 1.16E+01 : 1.16E+00 : 2.01E+00 :
XE133
Ci
1.16E-02 : 1.06E+03 : 7.85E+01 : 1.26E+02 :
XE135M
Ci
3.64E-05 : 7.53E-06 : 7.22E-05 : 1.44E-06 :
XE135
Ci
1.68E-03 : 4.54E-01 : 1.96E+00 : 4.80E+00 :
TOTAL FOR:
PERIOD
Ci 2.72E+02 1.53E+03 1.05E+02 1.79E+02 (ABOVE)

B-5

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 EFFLUENT AND WASTE DISPOSAL 2002 ANNUAL REPORT GASEOUS EFFLUENTS --

SUMMATION OF ALL RELEASES CONTINUOUS MODE BATCH MODE

NUCLIDES
UNITS :

QUARTER QUARTER QUARTER QUARTER

RELEASED 3

4 3

4

2. IODINES
I131
Ci
2.62E-04 : 2.88E-04 0.OOE+00 0.OOE+O0 :
TOTAL FOR :
PERIOD
Ci 2.62E-04 2.88E-04 :

0.OOE+00 0.OOE+00 (ABOVE)

CONTINUOUS MODE BATCH MODE

NUCLIDES
UNITS :

QUARTER QUARTER QUARTER QUARTER

RELEASED:

3 4

3 4

3. PARTICULATES
C058 Ci 0.OOE+00 :

1.85E-05 :

O.OOE+00 :

0.OOE+00 :

C060 Ci 2.37E-06 :

3.39E-06 :

0.OOE+00 : 0.OOE+00 :

CS137
Ci 3.98E-05 :

9.06E-06 :

0.OOE+00 :

0.OOE+00 :

  • N163
Ci 6.42E-07 :

1.26E-05 :

0.OOE+00 :

0.OOE+00 :

  • RB88 Ci 0.OOE+00 : 2.67E-02 : 5.87E-04 :

5.78E-02 :

TOTAL FOR:
PERIOD Ci 4.28E-05 2.67E-02 :

5.87E-04 :

5.78E-02 (ABOVE)

DENOTES SUPPLEMENTAL ISOTOPES B-6

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 ANNUAL EFFLUENT AND WASTE DISPOSAL REPORT C -

LIQUID EFFLUENTS 2002 ENTERGY NUCLEAR OPERATIONS, INC.

INDIAN POINT UNIT NOS. 1 & 2 DOCKET NOS. 50-03 & 50-247 MAY 2003

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 EFFLUENT AND WASTE DISPOSAL 2002 ANNUAL REPORT LIQUID EFFLUENTS --

SUMMATION OF ALL RELEASES UNITS QUARTER QUARTER

EST.

TOTAL:

1 2

ERROR, A. FISSION AND ACTIVATION PRODUCTS
1. TOTAL RELEASE (EXCL.:

Ci 1.81E-01 :

6.98E-02 :

1.50E+01 TRIT., GASES, ALPHA):

2. AVERAGE DILUTED
uCi/ML :

5.45E-10 :

1.89E-10 CONC. DURING PERIOD :

3. PERCENT OF 7.54E-04 :

5.30E-04 APPLICABLE LIMIT B. TRITIUM

1. TOTAL RELEASE Ci 1.54E+02 :

1.43E+02 :

1.50E+01 :

2. AVERAGE DILUTED
uCi/ml 4.62E-07 3.86E-07 CONC. DURING PERIOD :
3. PERCENT OF 5.08E-03 :

6.28E-03 APPLICABLE LIMIT C. DISSOLVED AND ENTRAINED GASES

1. TOTAL RELEASE Ci
1.67E-02 :

0.OOE+00 :

1.50E+01 :

2. AVERAGE DILUTED
uCi/ml :

5.01E-11 :

0.OOE+00 CONC. DURING PERIOD :

3. PERCENT OF 2.50E-05 :

0.OOE+00 APPLICABLE LIMIT D. GROSS ALPHA RADIOACTIVITY

1. TOTAL RELEASE Ci 8.58E-05 :

5.85E-05 :

5.OOE+01 :

E. VOLUME WASTE RELEASED :LITERS :

6.27E+07 :

5.08E+07 :

1.OOE+01

(PRIOR TO DILUTION)

F. VOLUME DILUTION WATER :LITERS :

3.33E+11 :

3.70E+11 :

1.OOE+01

USED DURING PERIOD C-1

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 EFFLUENT AND WASTE DISPOSAL 2002 ANNUAL REPORT LIQUID EFFLUENTS --

SUMMATION OF ALL RELEASES CONTINUOUS MODE BATCH MODE

NUCLIDES UNITS QUARTER QUARTER QUARTER QUARTER
RELEASED 1

2 1

2

H3
Ci
1.31E-01 : 1.95E-01 : 1.54E+02 : 1.43E+02 :
MN54
Ci
0.OOE+00 0.OOE+00 : 2.11E-04 : 4.73E-04 :
FE55
Ci
0.OOE+00 0.O0E+00 : 1.38E-03 : 1.14E-02 :
C058
Ci
1.35E-02 0.OOE+00 : 1.54E-02 : 1.50E-02 :
C060
Ci
0.OOE+00 0.OOE+00 : 7.51E-04 : 1.65E-03 :
NI63
Ci
1.25E-01 0.OOE+00 : 6.74E-03 : 7.33E-03 :
SR89
Ci
0.OOE+00 0.OOE+00 : 0.OOE+00 : 2.93E-05 :
SR90
Ci
4.59E-04 : 3.44E-04 : 1.91E-04 : 3.20E-04 :
NB95
Ci
0.OOE+00 0.OOE+00 0.OOE+00 : 1.06E-05 :
AGllOM
Ci
0.OOE+00 0.OOE+00 0.OOE+00 : 4.29E-05 :
CS134
Ci
0.OOE+00 0.OOE+00 0.OOE+00 : 1.13E-04 :
CS137
Ci
2.71E-04 : 5.64E-04 : 1.37E-02 : 2.56E-02 :
  • SB124
Ci
0.OOE+00 : 0.OOE+00 : 3.74E-04 : 1.82E-04 :

SB125

Ci
0.OOE+00 : 0.OOE+00 : 3.14E-03 : 1.33E-03 :

C057

Ci
0.OOE+00 : 0.OOE+00 : 4.46E-05 : 5.61E-05 :
  • CD109
Ci
0.00E+00 : 5.41E-03 : 0.00E+00 : 0.00E+00 :

C-2

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 EFFLUENT AND WASTE DISPOSAL 2002 ANNUAL REPORT LIQUID EFFLUENTS --

SUMMATION OF ALL RELEASES CONTINUOUS MODE BATCH MODE

NUCLIDES
UNITS QUARTER QUARTER QUARTER QUARTER
RELEASED 1

2 1

2 LIQUID EFFLUENTS (CONTD)

TOTAL FOR :
PERIOD
Ci 2.70E-01 2.02E-01 1.54E+02 1.43E+02 (ABOVE)

CONTINUOUS MODE BATCH MODE

NUCLIDES
UNITS QUARTER QUARTER QUARTER QUARTER
RELEASED 1

2 1

2

  • XE133
Ci
0.OOE+00 : O.OOE+00 : 1.67E-02 : 0.OOE+00 :

DENOTES SUPPLEMENTAL ISOTOPES C-3

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 EFFLUENT AND WASTE DISPOSAL 2002 ANNUAL REPORT LIQUID EFFLUENTS --

SUMMATION OF ALL RELEASES UNITS QUARTER QUARTER

EST.

TOTAL:

3 4

ERROR, A. FISSION AND ACTIVATION PRODUCTS
1. TOTAL RELEASE (EXCL.:

Ci 4.26E-02 :

1.48E-01 1.50E+01 TRIT., GASES, ALPHA):

2. AVERAGE DILUTED
uCi/ml :

1.02E-10 :

5.69E-10 CONC. DURING PERIOD :

3. PERCENT OF 4.42E-04 :

3.32E-03 APPLICABLE LIMIT B. TRITIUM

1. TOTAL RELEASE Ci 1.74E+02 :

5.94E+02 :

1.50E+01 :

2. AVERAGE DILUTED
uCi/ml :

4.14E-07 :

2.28E-06 CONC. DURING PERIOD :

3. PERCENT OF 6.85E-03 :

3.61E-02 APPLICABLE LIMIT C. DISSOLVED AND ENTRAINED GASES

1. TOTAL RELEASE Ci 2.91E-02 :

6.70E-02 :

1.50E+01 :

2. AVERAGE DILUTED
uCi/ml :

6.94E-11 :

2.57E-10 CONC. DURING PERIOD :

3. PERCENT OF 3.47E-05 1.29E-04 APPLICABLE LIMIT D. GROSS ALPHA RADIOACTIVITY
1. TOTAL RELEASE
Ci
1.63E-03 : 5.46E-04 : 5.OOE+01 :

E. VOLUME WASTE RELEASED :LITERS : 5.25E+07 5.33E+07 : 1.00E+01 (PRIOR TO DILUTION)

F. VOLUME DILUTION WATER :LITERS : 4.20E+11 : 2.60E+11 : 1.00E+01 USED DURING PERIOD C-4

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 EFFLUENT AND WASTE DISPOSAL 2002 ANNUAL REPORT LIQUID EFFLUENTS --

SUMMATION OF ALL RELEASES CONTINUOUS MODE BATCH MODE

NUCLIDES
UNITS QUARTER QUARTER QUARTER QUARTER
RELEASED 3

4 3

4

H3
Ci
8.42E-02 : 1.77E-02 : 1.73E+02 : 5.94E+02 :
NA24
Ci
0.OOE+00 0.OOE+00 0.OOE+00 : 1.28E-04 :
CR51
Ci
0.OOE+00 0.OOE+00 0.OOE+00 : 2.11E-03 :
MN54
Ci
0.OOE+00 0.OOE+00 : 8.77E-05 : 2.08E-04 :
FE55
Ci
0.OOE+00 0.O0E+00 0.OOE+00 : 1.90E-02 :
FE59
Ci
0.OOE+00 : 0.OOE+00 0.OOE+00 : 1.48E-05 :
C058
Ci
0.OOE+00 : 0.OOE+00 : 6.41E-03 : 2.54E-02 :
C060
Ci
0.OOE+00 : 0.O0E+00 : 1.49E-03 : 5.58E-03 :
NI63
Ci
0.OOE+00 : 5.37E-04 : 1.14E-02 : 1.72E-02 :
SR89
Ci
3.43E-04 : 2.21E-04 : 1.67E-04 : 1.88E-04 :
SR90
Ci
3.85E-04 : 3.24E-04 : 2.18E-04 : 2.88E-04 :
NB95
Ci
0.OOE+00 0.OOE+00 : 0.OOE+00 : 1.88E-05 :
AGlOM
Ci
0.OOE+00 0.O0E+00 0.OOE+00 : 1.27E-04 :
TE132
Ci
0.OOE+00 0.OOE+00 0.OOE+00 : 3.90E-05 :
I131
Ci
0.00E+00 0.OOE+00 : 0.00E+00 : 3.90E-03 :
I132
Ci
O.OOE+00 0.00E+00 0.OOE+00 : 5.56E-05 :
CS134
Ci
O.OOE+00 0.OOE+00 : 1.30E-04 : 6.56E-04 :

C-5

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 EFFLUENT AND WASTE DISPOSAL 2002 ANNUAL REPORT LIQUID EFFLUENTS --

SUMMATION OF ALL RELEASES CONTINUOUS MODE BATCH MODE

NUCLIDES
UNITS QUARTER QUARTER QUARTER QUARTER
RELEASED 3

4 3

4 LIQUID EFFLUENTS (CONTD)

CS137
Ci
5.29E-04 : 2.83E-07 : 2.01E-02 : 3.67E-02 :
CS138
Ci 0.OOE+00 : 0.OOE+00 : 0.OOE+00 :

9.36E-03 :

LA140
Ci
0.OOE+00 : 0.OOE+00 : 0.O0E+00 :

1.66E-04 :

  • SB124
Ci
0.OOE+00 :

0.OOE+00 : 1.18E-05 : 7.38E-03 :

  • SB125
Ci
0.OOE+00 : 0.00E+00 :

1.14E-03 :

1.65E-02 :

  • TE123M
Ci
0.00E+00 : 0.OOE+00 : 0.OOE+00 :

2.49E-04 :

  • C057
Ci 0.OOE+00 : 0.OOE+00 : 7.60E-05 :

1.92E-04 :

  • SB122
Ci
0.OOE+00 : 0.OOE+00 :

6.25E-06 : 0.OOE+00 :

  • CD109
Ci
0.OOE+00 : 1.74E-03 0.OOE+00 : 0.OOE+00 :
  • C059 Ci 0.OOE+00 :

0.OOE+00 : 2.52E-05 : O.OOE+00 :

TOTAL FOR:
PERIOD Ci 8.55E-02 2.06E-02 1.74E+02 5.94E+02 (ABOVE)

EFFLUENT AND WASTE DISPOSAL 2002 ANNUAL REPORT LIQUID EFFLUENTS --

SUMMATION OF ALL RELEASES CONTINUOUS MODE BATCH MODE

NUCLIDES
UNITS :

QUARTER QUARTER QUARTER QUARTER

RELEASED 3

4 3

4

  • XE133 Ci 0.OOE+00 :

0.OOE+00 :

8.23E-03 :

4.22E-02 :

  • XE131M Ci 0.OOE+00 : 0.OOE+00 :

0.OOE+00 :

1.54E-03 :

  • KR85 Ci 0.OOE+00 :

0.00E+00 : 2.09E-02 : 2.33E-02 :

DENOTES SUPPLEMENTAL ISOTOPES C-6

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 ANNUAL EFFLUENT AND WASTE DISPOSAL REPORT D -

SOLID WASTE 2002 ENTERGY NUCLEAR OPERATIONS, INC.

INDIAN POINT UNIT NOS. 1 & 2 DOCKET NOS. 50-03 & 50-247 MAY 2003

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 Solid Radwaste Disposal Report 2002. Solid Radwaste Shipped Offsite for Burial, Reprocessing, or Disposal (No irradiated fuel).

12 MONTH PERIOD

1.

Type of Waste

a.

Spent Resins, sludges, etc.

b. DAW
c. Irradiated components Units m3 Ci m3 ci Class A Class B 0

0 1200 6.75 0

0 38.6 14.7 0

0 Class C 0

0 0

0 3.4 26.4 Error, %

+I-25

+/- 25

+/- 25

+/- 25

+/- 25

+/- 25 m3 Ci 0

0 control rods, etc.

2.

Measurement of major nuclide composition in percent (by type of waste)

DAW Waste Class A Nuclide H-3 Mn-54 Fe-55 Co-57 Co-58 Co-60 Ni-59 NI-63 Sr-90 Zr-95 Nb-95 Tc-99 Ag-11 Om Sb-124 Sb-125 Cs-134 Cs-137 Ce-144 mCi 3.46E+00 4.56E+00 9.77E+02 3.56E-01 1.62E+02 2.68E+03 2.16E+01 1.37E+03 9.01 E+00 2.17E-01 9.01 E-02 2.27E+00 2.53E-02 4.94E-01 5.63E+00 9.35E+00 1.49E+03 9.20E+00 Percent 0.051%

0.068%

14.483%

0.005%

2.402%

39.729%

0.320%

20.309%

0.134%

0.003%

0.001%

0.034%

0.000%

0.007%

0.083%

0.139%

22.088%

0.136%

D-1

Pu-238 Pu-239 Pu-241 Am-241 Cm-242 Cm-243 1.02E-02 3.77E-03 4.07E-01 4.02E-02 4.68E-02 7.16E-03 6.75E+03 NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 0.000%

0.000%

0.006%

0.00 1%

0.00 1%

0.000%

Total DAW Waste Class B Nuclide H-3 Fe-55 Co-58 Co-60 Ni-63 Sr-90 Tc-99 Cs-134 Cs-1 37 Ce-144 Pu-238 Pu-239 Am-241 Cm-242 Cm-243 Total Irradiated Components Waste Class C Nuclide H-3 C-14 Mn-54 Fe-55 Fe-59 Co-58 Co-60 Ni-59 Ni-63 Sr-90 mCi 3.72E+01 9.43E+00 9.80E-01 4.08E+03 6.61 E+02 3.09E+00 8.13E+00 9.21 E-01 9.87E+03 1.44E+00 4.89E-03 3.72E-03 1.70E-02 4.14E-03 6.51 E-02 1.47E+04 mCi 7.26E+00 1.45E+00 4.56E+01 8.96E+03 3.36E-02 7.05E+00 1.61 E+04 1.1 8E+01 1.23E+03 7.11 E-03 Percent 0.254%

0.064%

0.007%

27.808%

4.505%

0.021%

0.055%

0.006%

67.270%

0.010%

0.000%

0.000%

' 0.000%

0.000%

0.000%

Percent 0.03%

0.01%

0.17%

33.95%

0.00%

0.03%

61.01%

0.04%

4.66%

0.00%

D-2

Nb-94 Tc-99 Sb-125 1-120 Cs-134 Cs-137 Ce-144 Pu-238 Pu-239 Pu-241 Am-241 Cm-242 Cm-244 1.93E-01 2.65E-01 2.51 E+00 2.48E-05 4.79E-01 2.25E+01 5.07E-01 9.39E-06 3.70E-06 2.30E-04 4.17E-03 1.OOE-02 4.27E-06 2.64E+04 NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 0.00%

0.00%

0.01%

0.00%

0.00%

0.09%

0.00%

0.00%

0.00%

0.00%

0.00%

0.00%

0.00%

Total

3.

Solid Waste Disposition Number Of Shipments Mode of Transport Destination 6

Hittman Transport GTS Duratek Galaher Road I

Hittman Transport Barnwell Waste Management Facility 26 Hittman Transport GTS Duratek Bear Creek 1

TAG Transport GTS Duratek Bear Creek

4.

Solid Waste Containers

a. 8-120 High Integrity Container - 120.3 cubic feet
b. 20' Sea Land - 1280 cubic feet
c. B-25 Steel Box - 96 cubic feet
d. 55 Gallon Drum - 7.5 cubic feet During 2002 one (1) Type B container was used for the shipment of an 8-120 liner in an 8-120 B shipping cask. All other shipments were LSA.

No solidification agents or absorbents were used Note: Waste characterization and classification is determined using the RADMAN software program.

D-3

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 ANNUAL EFFLUENT AND WASTE DISPOSAL REPORT E -

RADIOLOGICAL IMPACT ON MAN 2002 ENTERGY NUCLEAR OPERATIONS, INC.

INDIAN POINT UNIT NOS. 1 & 2 DOCKET NOS. 50-03 & 50-247 MAY 2003

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 RADIOLOGICAL IMPACT EVALUATION Doses from gaseous immersion, inhalation, ground deposition, and vegetation ingestion were evaluated for the nearest residence likely to be occupied in the critical sector for each pathway and were combined to provide a conservative determination of the maximum individual offsite radiation dose from these pathways.

Calculations were performed for members of the public on site for this reporting period.

To this end, it is assumed that members of the public on-site are exposed 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> per year.

Based on an assumed on-site location most likely to be occupied, a gaseous effluent dispersion factor is obtained. The dose is then computed with consideration for the total effluents released, the on-site dispersion factor and the exposure time.

Doses to such individuals were found to be significantly less than one percent of the maximum individual offsite dose.

Doses were also evaluated for all sectors assuming an individual ingesting milk and meat from a cow located at 5.0 mile distance.

In all cases these evaluations were performed using the models presented in Regulatory Guide 1.109.

All releases were evaluated using actual meteorological conditions existing during the release period.

Integrated dose from the population within 50 miles of Indian Point from gaseous effluents were computed based on the most current population data.*

Dose calculations for liquid pathways to individuals and populations are computed for a year.

The MIDAS computer program that is utilized for these calculations incorporated the calculation model and parameters that are presented in Regulatory Guide 1.109.

The fish, invertebrate, algae, drinking, shoreline, swimming and boating pathways are calculated for the adult, teenager, child and infant.

These calculations are performed for reasons such as estimating the population water consumption dose, the population recreation dose, and cost-benefit analysis.

NUREG-0017, "Calculation of Release of Radioactive Materials in Gaseous and Liquid Effluents from Pressurized Water Reactors", assumes an annual release of 8.0 Ci/yr of carbon-14.

Therefore, to be consistent with NUREG-0017, a release of 7.3 curies of carbon-14 was assumed for the year, (adjusted for actual power operating capacity) in addition to the radioactive materials measured in Indian Point's gaseous effluents.

This impact evaluation demonstrates that the dose commitment to man from the operation of Indian Point Unit Nos. 1 and 2 is negligible, and is well below the levels set forth in 10 CFR 20, 10 CFR 50, and the Indian Point Unit Nos. 1 and 2 Technical Specifications.

Population data was based on the 1990 census.

E-1

Re: In 2002 INDIAN POINT UNITS 1 AND 2 RADIOLOGICAL IMPACT ON MAN*

(Reference Regulatory Guide 1.21, Page 12)

A. Maximum Individual Doses (1) Pathways (Gaseous)

Total Body Skin Thyroid millirem millirem millirem a) Nobel Gas Immersion 3.96E-2 1.93E-1 N/A b) Inhalation 5.95E-1 N/A 6.04E-1 c) Ground Deposition 1.67E-3 1.96E-3 1.67E-3 d) Milk Ingestion 1.25E-1 N/A 1.43E-1 e) Meat Ingestion 1.73E-2 N/A 1.74E-2 f) Vegetable Ingestion 4.16E-1 N/A 4.20E-1 NL-03-068 May, 2003 Ban Point Unit Nos. 1 & 2 locket Nos. 50-03 & 50-247 Bone millirem N/A

1. 73E-1
1. 67E-3 4.27E-1
7. OOE-2
1. 33E+0 (2) Pathways (Liquid)

E-2

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 Maximum Dose to Individuals 2002 millirem:

BONE LIVER TOTAL BODY THYROID KIDNEY LUNG GI SKIN Shore Exposure ADULT TEEN CHILD 3.40E-04 4.70E-04

9. 60E-05 3.40E-04
4. 70E-04
9. 60E-05 3.40E-04 4.70E-04
9. 60E-05 3.40E-04 4. 70E-04
9. 60E-05 3.40E-04
4. 70E-04
9. 60E-05 3.40E-04
4. 70E-04
9. 60E-05 3.40E-04
4. 70E-04
9. 60E-05 4.OOE-04 5.40E-04 1.13E-04 Fresh Water Sport Fish ADULT TEEN CHILD
1. 75E-02 1.80E-02
2. 30E-02
1. 17E-02 1.21E-02
1. lOE-02 8.30E-03 5.OOE-03
2. 58E-03
1. 03E-03 8.78E-04 8.24E-04 4.10E-03 4.20E-03 3.60E-03 1.78E-03
1. 84E-03
1. 54E-03 1.34E-03
1. OOE-03
5. 60E-04
0. OOE+00
0. OOE+00
0. OOE+00 Fresh Water Invertebrate ADULT TEEN CHILD
5. 70E-03
5. 60E-03
7. OOE-03 3.40E-03 3.50E-03 3.20E-03 2.44E-03 1.57E-03
1. 05E-03
1. 64E-04 1.28E-04 1.26E-04
1. 09E-03 1.09E-03 9.70E-04
5. 60E-04
6. 20E-04
5. 30E-04
1. 78E-03 1.23E-03
4. 80E-04
0. OOE+00
0. OOE+00
0. OOE+00 Total All Pathways ADULT TEEN CHILD 2.40E-02 2.40E-02 2. 90E-02 1.51E-02 1.63E-02 1.44E-02
1. llE-02
7. lOE-03 3.70E-03 1.53E-02 1.43E-03
1. 04E-03 5.60E-03
5. 80E-03
4. 60E-03
2. 63E-03 2.70E-03 1.14E-03 3.40E-03 2.70E-03 1.14E-03
4. OOE-04 5.40E-04
1. 13E-04 N/A = Not Applicable
  • See analogous Entergy Effluent report for Indian Point Unit public.

No. 3 to calculate a combined dose to the E-3

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 2002 B. Population (1)

Pathways (Gaseous)

Total Body (Man-rem)

Thyroid*

(Man-rem) a) Nobel Gas Immersion l.lE+01 l.1E+0l b) Inhalation 3.OE+01 3.OE+0l c) Ground Deposition 2.OE-02 2.OE-02 d) Totals 4.1E+01 4.1E+01

  • The thyroid values consist of a sum of total body and thyroid.

(2)

Pathways (Liquid)

Liquid Population Dose 2002 Person-rem:

Shore Exposure Bone Liver Total Body Thyroid Kidney Lung GI Skin 0.08 0.08 0.08

0. 08 0.08 0.08 0.08 0.10 Fresh Water Sport Fish Ingestion 6.70E-02 4.20E-02 2.50E-02 2.80E-03 1.50E-02 6.20E-03 4.10E-03 0

Commercial Fish Ingestion 1.lOE-01 7.20E-02 4.30E-02 4.70E-03 2.50E-02 1.lOE-02 7.OOE-03 0

Fresh Water Invertebrate Ingestion l.lOE-02 6.20E-03 3.80E-03 2.50E-04 1.90E-03 1.OOE-03 2.70E-03 0

C. Average Dose to Individuals (1)

Pathways a) Liquid-Total Body 2.58E-6 millirem b) Gaseous-Total Body 2.65E-3 millirem E-4

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

JAN/FEB/MAR 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD [Year/Month/Day/Hour)

[2002/ 1/ I/ 0]

TO

[2002/ 3/31/23]

PASQUILL STABILITY:

A WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 24.00 -

80.00 N

NNE NE ENE

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

.0 3.0 6.0 4.0 1.0 1.0

.0

.0 4.0 6.0 2.0 3.0 1.0 1.0 1.0 2.0 3.0

7. 0
11. 0 1.0

.0

.0

. 0

.0 21.0 8.0 1.0 2.0 4.0 12.0 22.0 26.0 6.0 8.0 3.0

.0

.0 8.0 6.0 2.0 8.0 6.0 2.0

5. 0 2.0 8.0 16.0 1.0
2. 0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 TOTAL 20.0 20.0 5.0 1.0 1.0

.0

.0 33.0 20.0 5.0 10.0 8.0 15.0 31.0 44.0 10.0 S

SSW SW WSW

.0

.0

.0

.0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0 38.0 121.0 62.0 2.0

.0

.0 223.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 10.00 50.90 10 2150 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-5

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

JAN/FEB/MAR 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/ 1/ 1/ 0]

TO

[2002/ 3/31/23]

PASQUILL STABILITY:

B WIND SPEED (MPH)

WIND FROM N

NNE NE ENE

.60 -

3.50 -

7.50 -

12.50 -

CALMS 3.50 7.50 12.50 18.50 18.50 -

24.00 24.00 -

80.00

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

.0

.0 1.0 1.0

.0 2.0 2.0

. 0 2.0

2. 0 10.0 2.0

. 0

.0 2.0 2.0

.0 6.0 3.0

.0

.0

.0

.0

.0 7.0 8.0 2.0 5.0 4.0 5.0 7.0 8.0 10.0 4.0 3.0

. 0 3.0 8.0 3.0

.0 3.0 8.0 3.0 7.0 3.0

1. 0

.0

7. 0 3.0
1. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

. 0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 TOTAL 11.0 6.0 1.0

.0

.0 2.0

.0 10.0 18.0 15.0 7.0 4.0 6.0 7.0 17.0 13.0 S

SSW SW WSW

.0

.0

.0

.0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0 19.0 65.0 32.0 1.0

.0

.0 117.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 10.00 50.90 10 2150 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-6

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

JAN/FEB/MAR 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/ 1/ 1/ 0)

TO

[2002/ 3/31/23)

PASQUILL STABILITY:

C WIND SPEED (MPH)

WIND FROM

.60 -

3.50 3.50 -

7.50 7.50 -

12.50 -

18.50 -

12.50 18.50 24.00 24.00 -

80.00 CALMS TOTAL N

NNE NE ENE

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

.0 1.0

.0

.0

.0

.0

.0 1.0 2.0 2.0 1.0 1.0

.0

.0

. 0

1. 0
1. 0 11.0 6.0 3.0 1.0 5.0 6.0 6.0 5.0 6.0
6. 0 4.0 9.0 6.0 8.0 7.0 2.0 1.0

.0

.0 2.0 1.0 1.0 2.0 12.0 1.0 1.0 1.0

2. 0
7. 0
1. 0

.0

.0

.0

.0

.0

.0

.0

.0

1. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

. 0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0 14.0 7.0 3.0 1.0

.0

.0

1. 0 9.0 21.0 8.0 6.0 3.0 11.0 13. 0
12. 0 9.0 S

SSW SW WSW

.0

.0

.0

. 0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0 10.0 75.0 32.0 1.0

.0

.0 118.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 10.00 50.90 10 2150 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-7

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

JAN/FEB/MAR 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD [Year/Month/Day/Hour)

[2002/ 1/ 1/ 0]

TO

[2002/ 3/31/23]

PASQUILL STABILITY:

D WIND SPEED (MPH)

WIND FROM

.60 -

CALMS 3.50 3.50 -

7.50 -

7.50 12.50 12.50 -

18.50 18.50 -

24.00 24.00 -

80.00 TOTAL N

NNE NE ENE E

ESE SE SSE

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

. 0

.0

.0

.0

14. 0 11.0 13.0 6.0 10.0 6.0 16.0 20.0 28.0 15.0 11.0 10.0 5.0 6.0 5.0 12.0 59.0 51.0 7.0 2.0 2.0 4.0 3.0 32.0 57.0 25.0 16.0 18.0 51.0 64.0 82.0 50.0 36.0 23.0 1.0

.0

.0

.0

.0 12.0 21.0 2.0 2.0 3.0

11. 0 35.0 43.0 18.0
4. 0

.0 2.0

.0

.0 2.0

.0

.0

2. 0

.0

.0

.0

.0

2. 0
1. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 113. 0 85.0 21.0 8.0

12. 0 10.0 19.0 64.0 108.0 42.0 29.0 31.0 67.0 107.0 131.0 80.0 S

SSW SW WSW W

WNW NW NNW TOTAL

.0 188.0 523.0 207.0 9.0

.0

.0 927.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS.

DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER.

DURING THIS PERIOD (ALL STABILITIES) 10.00 50.90 10 2150 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-8

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

JAN/FEB/MAR 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/ 1/ 1/ 0]

TO

[2002/ 3/31/23]

PASQUILL STABILITY:

E WIND SPEED (MPH)

WIND FROM

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

3.50 7.50 12.50 18.50 24.00 80.00 CALMS TOTAL N

NNE NE ENE

. 0

. 0

. 0

. 0 E

ESE SE SSE

. 0

. 0

. 0

. 0 18.0 36.0 16.0

11. 0 13. 0 15.0 19.0 21.0 46.0 45.0 30.0 19.0 22.0 12. 0 15.0 11.0 9.0 18.0 15.0 4.0 1.0

.0

.0 6.0 71.0 18.0 10.0 4.0 11.0 8.0 13. 0 1.0

. 0 3.0

.0

.0

.0 1.0 9.0 1.

9.0 2.0

. 0

. 0

. 0

.0

.0

.0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0 1.0

. 0

. 0

. 0

. 0

2. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

. 0

.0

. 0

. 0

.0

.0

.0

.0

.0 27.0 57.0 31.0 15.0

14. 0 15.0 19.0 28.0 127.0 65.0 40.0 23.0 33.0 22.0 28.0 12.0 S

SSW SW WSW

. 0

. 0

. 0

. 0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0 349.0 189.0 15.0 3.0

.0

.0 556.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 10.00 50.90 10 2150 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-9

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

JAN/FEB/MAR 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD [Year/Month/Day/Hour)

[2002/ 1/ 1/ 0]

TO

[2002/ 3/31/23]

PASQUILL STABILITY:

F WIND SPEED (MPH)

WIND FROM

.60 -

CALMS 3.50 3.50 -

7.50 7.50 -

12.50 12.50 -

18.50 18.50 -

24.00 N

NNE NE ENE

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

.0 18.0 28.0

11. 0 3.0 4.0 4.0 4.0 4.0 10.0 18.0 5.0 4.0 4.0 5.0 2.0
10. 0 1.0 10.0 11.0

.0 1.0

.0

.0 1.0 2.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 24.00 -

80.00

_ ___.0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

. 0 TOTAL 19.0 38.0 22.0 3.0 4.0 4.0 4.0 5.0 12.0 18.0 5.0 4.0 4.0 5.0 2.0 10.0 S

SSW SW WSW

.0

.0

.0

.0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0 134.0 25.0

.0

.0

.0

.0 159.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 10.00 50.90 10 2150 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-10

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS JAN/FEB/MAR 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/ 1/ 1/ 0]

TO

[2002/ 3/31/231 PASQUILL STABILITY:

G WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 24.00 -

80.00 N

NNE NE ENE

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

.0 14.0 7.0 3.0 2.0 1.0

.0

.0 1.0 2.0

. 0

.0 1.0

1. 0 2.0 2.0 3.0

.0

1. 0 10.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 1.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0 TOTAL 14.0 8.0 14.0 2.0 1.0

.0

.0 1.0 2.0

.0

.0

.0 1.0 2.0 2.0 3.0 S

SSW SW WSW

.0

.0

.0

.0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0 38.0 11.0 1.0

.0

.0

.0 50.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 10.00 50.90 10 2150 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-11

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS -

JAN/FEB/MAR 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/ 1/ 1/ 0)

TO

[2002/ 3/31/23)

PASQUILL STABILITY: ALL WIND SPEED (MPH)

WIND FROM CALMS

.60 -

3.50 -

7.50 -

12.50 -

3.50 7.50 12.50 18.50 18.50 -

24.00 24.00 -

80.00 N

NNE NE ENE

. 0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

.0 68.0 88.0 48.0 23.0 29.0 27.0 40.0

52. 0 96.0 91.0 52.0 34.0 33.0 26.0 29.0 40.0 93.0 100. 0 47.0 7.0 3.0 4.0 3.0 72.0 152.0 52.0 37.0 33.0 88.0 107.0 137.0
74. 0 50.0 33.0 2.0

.0

.0

.0

.0 26.0 56.0

10. 0 8.0 6.0 16.0 50.0 69.0 23.0 7.0

. 0

.0

.0

.0

.0

.0

. 0 4.0

.0

.0

.0

.0 4.0 1.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0 TOTAL 218.0 221.0 97.0 30.0 32.0 31.0 43.0 150.0 308.0 153.0 97.0 73.0 137.0 187.0 236.0 137.0 S

SSW SW WSW

.0

.0

.0

.0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0 776.0 1009.0 349.0 16.0

.0

.0 2150.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 10.00 50.90 10 2150 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-12

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS - JAN/FEB/MAR 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M)

FOR PERIOD [Year/Month/Day/Hour)

[2002/ 1/ I/ 0]

TO

[2002/ 3/31/23]

PASQUILL STABILITY:

A WIND SPEED (MPH)

WIND FROM

.60 -

3.50 3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

7.50 12.50 18.50 24.00 80.00 CALMS TOTAL N

NNE NE ENE

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

.0 3.0 1.0

.0 1.0 3.0

.0 2.0 1.0

.0 2.0 2.0 2.0 1.0

.0 1.0

. 0 1.0 3.0 7.0 5.0 1.0

1. 0

. 0 9.0 5.0 1.0

.0

.0 1.0

.0 1.0

.0 10.0 2.0

.0

.0

.0

.0

.0 19.0 7.0

.0 1.0 2.0 7.0 9.0 5.0 4.0 9.0

.0

.0

. 0

. 0

.0

.0 8.0 1.0 3.0 6.0

6. 0 1.0 17.0 26.0

.0

.0

.0

.0

.0

.0

.0 4.0

.0 1.0 3.0

4. 0

.0 1.0

3. 0 13.0
1. 0
5. 0

. 0

. 0 2.0

.0 1.0 1.0 1.0

.0

.0

2. 0

.0

.0

1. 0 28.0 6.0 7.0 6.0 4.0 1.0 2.0 37.0 13.0 6.0 9.0 10.0 11.0 30.0 47.0 6.0 S

SSW SW WSW

.0

.0

.0

.0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0 19.0 35.0 66.0 71.0 22.0 10.0 223.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 60.00 50.90 10 2150 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-13

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

JAN/FEB/MAR 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/ 1/ 1/ 0]

TO

[2002/ 3/31/23]

PASQUILL STABILITY:

B WIND SPEED (MPH)

WIND FROM

.60 3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

3.50 7.50 12.50 18.50 24.00 80.00 CALMS TOTAL N

NNE NE ENE

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

.0

. 0

. 0

.0 1.0

.0

.0

.0 2.0

.0

.0

.0 1.0

.0

.0

.0

1. 0 3.0 2.0

.0

.0 1.0 5.0 1.0 5.0 7.0

5. 0 3.0 3.0

. 0

1. 0
1. 0 2.0 6.0
1. 0

.0

.0

.0

.0 6.0 4.0 3.0 1.0 2.0 4.0 2.0

.0 3.0 3.0 1.0

.0

.0

.0

. 0 3.0 3.02.0 7.0

2. 0 1.0
1. 0 5.0 9.0 4.0 3.0

.0

.0

. 0

.0

.0 4.0 1.0

1. 0

.0

. 0

. 0

. 0

. 0 4.0 1.0

1. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

.0

1. 0

. 0

1. 0

. 0 16.0 4.0

.0 1.0

.0

.0 1.0 16.0

12. 0 15.0 6.0 6.0 6.0 8.0 15.0 11.0 S

SSW SW WSW

.0

.0

.0

.0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0 5.0 33.0 32.0 35.0 9.0 3.0 117.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 60.00 50.90 10 2150 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-14

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

JAN/FEB/MAR 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/ 1/ 1/ 0]

TO

[2002/ 3/31/23]

PASQUILL STABILITY:

C WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 N

NNE NE ENE

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

.0

. 0 2.0

.0 1.0

.0

.0

.0

.0 2.0

.0

1. 0

.0

.0

.0

.0

1. 0 7.0
1. 0 2.0 1.0
1. 0

.0

.0 5.0 5.0 3.0 5.0

.0 2.0 1.0

.0 3.0 6.0 3.0

.0

.0

.0

.0

.0 1.0 5.0 1.0 2.0 1.0 3.0 6.0 3.0 2.0

5. 0

.0

.0 2.0 6.0 3.0

.0 2.0

6. 0 3.0 4.0 1.0
4. 0 7.0
1. 0

.0

.0

. 0

.0

.0

. 0

. 0

. 0 2.0 1.0

.0

.0

.0 1.0 2.0 1.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 1.0 1.0

.0 1.0 3.0

.0

.0 TOTAL 18.0 4.0 2.0 1.0 1.0

.0

.0 8.0 20.0 9.0 9.0 2.0 9.0 15.0 12.0 8.0 S

SSW SW WSW

.0

.0

.0

.0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0 4.0 36.0 33.0 32.0 7.0 6.0 118.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 60.00 50.90 10 2150 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-15

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

JAN/FEB/MAR 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/ 1/ 1/ 0)

TO

[2002/ 3/31/23]

PASQUILL STABILITY:

D WIND SPEED (MPH)

WIND FROM CALMS

.60 3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

3.50 7.50 12.50 18.50 24.00 80.00 N

NNE NE ENE

.0

.0

.0

.0 E

ESE SE SSE

. 0

. 0

. 0

. 0 2.0 5.0 3.0 5.0 3.0 2.0 5.0 4.0 8.0 5.0 5.0 6.0 1.0 1.0 1.0

.0 18.0 27.0 11.0 7.0 6.0 10.0

13. 0 18.0 35.0 21.0 10.0 5.0 6.0 6.0 9.0
13. 0 35.0 26.0 2.0

.0 1.0 5.0 9.0 27.0 28.0 12.0 9.0 16.0 33.0

22. 0 43.0 29.0 39.0
5. 0

.0

.0 6.0

.0 3.0 14.0

6. 0
16. 0 3.0 7.0 23.0 47.0 61.0 14.0 20.0 1.0

.0

.0

.0

.0

.0 4.0 3.0 3.0 1.0 4.0 1.0 17.0 21.0 10.0 10.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0 2.0 6.0

14. 0 7.0 TOTAL 124.0 64.0 16.0 12.0 10.0 17.0 27.0 67.0 80.0 57.0 28.0 38.0 66.0 99.0 149.0 73.0 S

SSW SW WSW

.0

.0

.0

.0 W

WNW NW NNW

. 0

. 0

.0

.0 TOTAL

.0 56.0 215.0 297.0 235.0 85.0 39.0 927.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 60.00 50.90 10 2150 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-16

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

JAN/FEB/MAR 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/ 1/ 1/ 0)

TO

[2002/ 3/31/23)

PASQUILL STABILITY:

E WIND SPEED (MPH)

WIND FROM

.60 -

3.50 3.50 -

7.50 7.50 -

12.50 -

18.50 -

24.00 -

12.50 18.50 24.00 80.00 CALMS TOTAL N

NNE NE ENE E

ESE SE SSE

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 5.0 6.0 5.0 2.0 2.0 3.0 4.0 7.0 8.0 8.0 15.0 12.0 11.0 4.0 1.0 1.0 8.0 28.0 9.0 2.0 5.0 5.0 5.0 25.0 35.0 51.0 23.0

12. 0
12. 0 15.0 6.0 2.0 14.0 10.0
1. 0

.0 1.0 5.0 1.0 5.0 3 1. 0

45. 0 23.0 17.0 7.0
12. 0 11.0 4.0 2.0 2.0

.0

.0 2.0 7.0 5.0 2.0 7.0

5. 0 3.0
1. 0
1. 0 5.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 1.0

.0 1.0

.0

.0

.0 2.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0 1.0

.0

.0

.0

.0 2.0

.0

.0 29.0 46.0 15.0 4.0 7.0 8.0 10.0 39.0 83.0 109. 0 65.0 42.0 31.0 36.0 25.0 7.0 S

SSW SW WSW W

WNW NW NNW TOTAL

.0 94.0 243.0 181.0 31.0 4.0 3.0 556.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 60.00 50.90 10 2150 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-17

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

JAN/FEB/MAR 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M)

FOR PERIOD [Year/Month/Day/Hour)

[2002/ 1/ 1/ 0)

TO

[2002/ 3/31/23]

PASQUILL STABILITY:

F WIND SPEED (MPH)

WIND FROM N

NNE NE ENE

.60 -

CALMS 3.50

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

.0 6.0 3.0 2.0

.0 1.0 1.0 2.0 5.0 11.0 6.0 6.0 3.0 3.0 5.0 2.0 2.0 3.50 -

7.50 5.0 17.0 5.0 1.0

. 0

.0 3.0 3.0 19.0 9.0 5.0 3.0 3.0

.0 1.0

1. 0 7.50 -

12.50 2.0 3. 0

. 0

.0

.0

.0

.0 3.0 12.0 3.0 1.0 2.0

.0

.0

.0 12.50 -

18.50

.0

.0 1.0 1.0

.0 1.0

.0

.0

1. 0
1. 0

.0

1. 0

.0

.0

.0

.0 18.50 -

24.00 24.00 -

80.00

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 TOTAL 13.0 23.0 7.0 1.0 1.0 1.0 2.0 8.0 43.0 19.0 12.0 9.0 9.0 5.0 3.0 3.0 S

SSW SW WSW

.0

.0

.0

.0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0 58.0 72.0 26.0 3.0

.0

.0 159.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS.

DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER.

DURING THIS PERIOD (ALL STABILITIES) 60.00 50.90 10 2150 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-18

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - JAN/FEB/MAR 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/ 1/ 1/ 0]

TO

[2002/ 3/31/23]

PASQUILL STABILITY:

G WIND SPEED (MPH)

WIND FROM

.60 -

3.50 3.50 -

7.50 7.50 -

12.50 12.50 -

18.50 18.50 -

24.00 24.00 -

80.00 CALMS TOTAL.

N NNE NE ENE

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

.0

. 0

1. 0 4.0 2.0

.0

.0 1.0 2.0 4.0 2.0 2.0 2.0

.0

.0

.0

.0

.0 8.0 2.0

.0

.0

.0 1.0

1. 0 9.0 4.0

.0 2.0

. 0

1. 0 1.

.0

.0

1. 0

.0

. 0

.0

.0

.0

.0

.0

.0 1.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

. 0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0 10.0 6.0 2.0

.0

.0 1.0 3.0 13.0 6.0 2.0 4.0

.0 2.0

1. 0

. 0 S

SSW SW WSW

.0

.0

.0

.0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0 20.0 28.0 2.0

.0

.0

.0 50.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 60.00 50.90 10 2150 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-19

NL-03-068 May, 2003 Re: Indian Point Unit Nos. I & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

JAN/FEB/MAR 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M)

FOR PERIOD [Year/Month/Day/Hour)

[2002/ 1/ 1/ 0)

TO

[2002/ 3/31/23]

PASQUILL STABILITY:

ALL WIND SPEED (MPH)

WIND FROM CALMS

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

3.50 7.50 12.50 18.50 24.00 80.00 N

NNE NE ENE

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

.0 16.0 16.0

14. 0 11.0 9.0 6.0
14. 0 21.0 33.0 23.0 31.0 26.0 16.0 10.0 5.0 5.0 42.0 86.0 36.0 16.0
13. 0 16.0 19.0 66.0 115. 0
94. 0 46.0 25.0 24.0 24.0 19.0 21.0 73.0 46.0 3.0

.0

1. 0
5. 0 10.0 58.0 87.0
64. 0 37.0 40.0 57.0
52. 0 62.0 42.0 58.0 8.0

.0

.0

.0

.0

.0 29.0 21.0

35. 0
16. 0
29. 0
76. 0 108.0 19.0 23.0 1.0

.0

. 0

.0

.0

.0 4.0 7.0 4.0 6.0 4.0 2.0 21.0 42.0 13.0 16.0

.0

.0

.0

.0

.0

.0

.0 1.0 1.0 3.0

.0 4.0 12.0 16.0 8.0 TOTAL 228.0 157.0 53.0 27.0 23.0 27.0 43.0 178.0 264. 0 221.0 131.0 111.0 132.0 195.0 252.0 108.0 S

SSW SW WSW

.0

.0

.0

.0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0 256.0 662.0 637.0 407.0 127.0 61.0 2150.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 60.00 50.90 10 2150 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-20

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

JAN/FEB/MAR 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M)

FOR PERIOD [Year/Month/Day/Hour)

[2002/ 1/ 1/ 0)

TO

[2002/ 3/31/23]

PASQUILL STABILITY:

A WIND SPEED (MPH)

WIND FROM N---

N NNE NE ENE E

ESE SE SSE CALMS

.0

. 0

.0

.0

.0

.0

.0

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

3.50 7.50 12.50 18.50 24.00 24.00 -

80.00 TOTAL

.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 1.0

.0

.0

. 0

.0

.0

.0

.0

.0

. 0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 5.0

.0

.0

. 0 1.0

.0 2.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0 1.0 1.0

.0 4.0

.0

.0

.0

.0

.0

.0

.0

.0 S

SSW SW WSW

.0

.0

.0

.0

.0

.0

.0

.0

.0 1.0

.0

.0 1.0

. 0 1.0 1.0

.0

.0 6.0

.0

.0

1. 0 1.0

.0 4.0 1.0 1.0 5.0 W

WNW NW NNW

. 0

.0

.0

.0 TOTAL

.0

.0 1.0

.0 8.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 6.0 122.00 112.00 10 2150 4.0 19.0 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-21

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

JAN/FEB/MAR 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/ 1/ 1/ 0)

TO

[2002/ 3/31/23]

PASQUILL STABILITY:

B WIND SPEED (MPH)

WIND FROM

.60 -

3.50 3.50 -

7.50 7.50 -

12.50 -

18.50 -

24.00 -

12.50 18.50 24.00 80.00 CALMS TOTAL N

NNE NE ENE

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 2.0

.0

.0

.0

.0 2.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 S

SSW SW WSW

.0

.0

.0

.0

.0 3.0 1.0 1.0

.0 1.0 1.0 8.0

.0

.0

1. 0
1. 0

.0

1. 0
1. 0
8. 0

. 0 3.0

.0 2.0 1.0 8.0 3.0

.0 1.0

.0

2. 0
1. 0 8.0
6. 0

.0

1. 0
21. 0

.0

.0

.0

.0

.0

.0

1. 0

. 0

.0 2.0

1. 0

.0 4.0 3.0 1.0 2.0 14. 0

.0

.0

.0

.0

.0 2.0

.0

.0

.0 4.0 1.0

.0 7.0

.0

.0 9.0 1.0

.0 4.0 3.0 2.0 13.0 13.0 3.0 4.0 52.0

.0

.0

.0

.0

.0

.0

.0

.0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0

.0 2.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 122.00 112.00 10 2150 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-22

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -- JAN/FEB/MAR 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M)

FOR PERIOD [Year/Month/Day/Hour)

[2002/ 1/ 1/ 0)

TO

[2002/ 3/31/23)

PASQUILL STABILITY:

C WIND SPEED (MPH)

WIND FROM

.60 -

3.50 3.50 -

7.50 -

7.50 12.50 12.50 -

18.50 -

18.50 24.00 24.00 -

80.00 CALMS TOTAL N

NNE NE ENE

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 5.0

.0 1.0 5.0

.0 1.0

.0

.0

1. 0

.0

1. 0

.0

1. 0

.0

.0

.0

. 0

.0 5.0

5. 0 3.0 1.0 1.0 2.0 9.0 4.0 3.0 1.0 5.0

.0

.0 3.0 6.0 1.0 3.0 3.0 15.0 61.0 1.0 3.0

2. 0
15. 0
13. 0 1.0 2.0

.0

.0

.0

. 0

.0

.0

.0

.0 2.0

.0

.0

.0 3.0 6.0 2.0 3.0 S

SSW SW WSW

.0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

. 0

.0

.0

.0 1.0

.0 1.0 1.0 3.0

.0

1. 0

.0

.0 13.0 4.0 9.0 3.0 5.0 13.0 23.0 26.0 4.0 12.0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0

.0 8.0 34.0 47.0 16.0 7.0 112.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 122.00 112. 00 10 2150 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-23

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

JAN/FEB/MAR 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M)

FOR PERIOD [Year/Month/Day/Hour)

[2002/ 1/ 1/ 0]

TO

[2002/ 3/31/23]

PASQUILL STABILITY:

D WIND SPEED (MPH)

WIND FROM N

NNE NE ENE

.60 -

CALMS 3.50 3.50 -

7.50 -

12.50 -

7.50 12.50 18.50 E

ESE SE SSE

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 3.0 7.0 4.0 3.0 7.0 7.0 5.0 4.0 4.0 6.0

.0 1.0 1.0

.0 3.0

.0 22.0 23.0

14. 0 8.0 10.0
11. 0 26.0 36.0 15.0 9.0 13.0 7.0 6.0
12. 0 24.0 15.0 37.0 2.0 3.0 6.0 10.0 14.0 28.0 36.0 20.0 27.0 23.0
32. 0 30.0 40.0 23.0 37.0 15.0

.0

.0 1.0 2.0 3.0 23.0 16.0 30.0 7.0

13. 0 36.0 62.0 82.0 26.0 49.0 18.50 -

24.00 5.0

.0

. 0

.0

.0 3.0 7.0 10.0 3.0 2.0 9.0 44.0 32.0 5.0 17.0 24.00 -

80.00

_ ___.0

.0

.0

.0

.0

.0

.0

.0 2.0

2. 0 1.0 2.0 5.0
15. 0 28.0 6.0 22.0 TOTAL 82.0 32.0 21.0 18.0 29.0 35.0 85.0 99.0 81.0 53.0
53. 0 90.0 158.0 194.0 87.0 140.0 S

SSW SW WSW W

WNW NW NNW TOTAL

.0 55.0 251.0 368.0 365.0 137.0 81.0 1257.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 122.00 112.00 10 2150 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-24

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

JAN/FEB/MAR 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/ 1/ 1/ 0]

TO

[2002/ 3/31/23)

PASQUILL STABILITY:

E WIND SPEED (MPH)

WIND FROM

.60 -

CALMS 3.50 N

NNE NE ENE E

ESE SE SSE

. 0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 1.0 3.0 2.0 1.0 2.0 4.0 8.0 8.0 6.0 8.0 7.0 2.0 1.0 1.0 2.0 1.0 3.50 -

7.50 15.0 4.0 2.0 2.0 4.0 6.0 41.0 63. 0 31.0 18.0

12. 0 7.0 11.0 4.0 3.0 10.0 3.0

.0

.0 3.0 3.0

3. 0 20.0 59.0 38.0 23.0 17.0 5.0 11.0 3.0 5.0 16.0 6.0

.0

.0 8.0 9.0 3.0 6.0 14. 0

15. 0 8.0
9. 0 3.0 4.0 1.0 1.0
7. 0

.0

.0

.0

.0

.0

.0 3.0 8.0

.0

.0 1.0

.0

.0

.0

. 0

. 0 7.50 -

12.50 -

18.50 -

12.50 18.50 24.00 24.00 -

80.00

_ ___.0

.0

.0

. 0

.0

.0

. 0 2.0 3.0 1.0

.0

.0

.0 1.0

.0

.0

.0 TOTAL 19.0 7.0 4.0 6.0 6.0 13.0 80.0 155.0 91.0 57.0 46.0 17.0 27.0 8.0 11.0 34.0 S

SSW SW WSW W

WNW NW NNW TOTAL

.0 56.0 233.0 206.0 67.0 12.0 7.0 581.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 122.00 112.00 10 2150 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-25

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

JAN/FEB/MAR 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/ 1/ 1/ 0]

TO

[2002/ 3/31/23]

PASQUILL STABILITY:

F WIND SPEED (MPH)

WIND FROM

.60 -

3.50 3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

7.50 12.50 18.50 24.00 80.00 CALMS TOTAL N

NNE NE ENE

.0

.0

.0

.0 E

ESE SE SSE

. 0

. 0

. 0

.0 1.0 4.0 4.0 3.0 2.0 3.0 5.0 2.0 3.0 2.0 3.0 4.0 1.0

.0

.0

.0 4.0 4.0 3.0

.0 9.0

.0 9.0 11.0 10.0 6.0 3.0 2.0 2.0 3.0

.0 2.0

1. 0

. 0

1. 0

.0

.0

.0 1.0 8.0 8.0 2.0

.0

.0

.0 3.0

.0 2.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 1.0

.0 1.0

1. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 6.0 8.0 8.0 3.0 2.0 3.0 15.0 21.0 21.0 10.0 7.0 6.0 4.0 6.0 1.0 4.0 S

SSW SW WSW

.0

.0

.0

.0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0 37.0 59.0 26.0 3.0

.0

.0 125.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 122.00 112.00 10 2150 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-26

NL-03-068 May, 2003 Re: Indian Point Unit Nos. I & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS JAN/FEB/MAR 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/ I/ 1/ 0]

TO

[2002/ 3/31/23)

PASQUILL STABILITY:

G WIND SPEED (MPH)

WIND FROM

.60 -

CALMS 3.50 3.50 -

7.50 7.50 -

12.50 -

18.50 -

12.50 18.50 24.00 24.00 -

80.00 TOTAL N

NNE NE ENE E

ESE SE SSE

.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

. 0

. 0

. 0

.0

.0

.0

.0

.0

.0

.0 1.0

.0 1.0 1.0

.0

. 0 1.0

. 0

.0

. 0

.0

. 0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0 1.0 1.0

1. 0
1. 0

.0

.0

1. 0 S

SSW SW WSW W

WNW NW NNW

.0

.0

.0

.0

.0

.0

.0

.0 TOTAL

.0 4.0

.0

.0

.0

. 0

.0 4.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 122.00 112.00 10 2150 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-27

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

JAN/FEB/MAR 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M)

FOR PERIOD [Year/Month/Day/Hour)

[2002/ 1/ 1/ 0]

TO

[2002/ 3/31/23)

PASQUILL STABILITY:

ALL WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 N

NNE NE ENE

.0

. 0

. 0

. 0 E

ESE SE SSE

.0

.0

.0

.0 5.0 14.0 10.0 7.0 11.0 15.0 18.0 15.0

14. 0 16.0 10.0 8.0 2.0 1.0 5.0 1.0 41.0 31.0 19.0 10.0
14. 0 17.0 84.0 110.0 56.0 33.0 28.0 17.0 19.0 20.0 27.0 28.0 41.0 2.0 4.0 9.0 10.0
17. 0 57.0 107.0 67.0 53.0 42.0 47.0 46.0 49.0 30.0 61.0 15.0

.0

.0 1.0 2.0 3.0 40.0 31.0 51.0 16.0 29.0 42.0

92. 0 101. 0 29.0 59.0 5.0

.0

.0

.0

.0

.0 7.0 15.0

12. 0 5.0 4.0 9.0 52.0 42.0 8.0 26.0 24.00 -

80.00

.0

.0

.0

.0

.0

.0 2.0 3.0 3.0 5.0 2.0 6.0 18.0 35.0 8.0 24.0 TOTAL 107.0 47.0 33.0 27.0 37.0 52.0 208.0 281.0 203.0 128.0 115.0 129.0 229.0 248.0 107.0 199.0 S

SSW SW WSW

. 0

. 0

. 0

. 0 W

WNW NW NNW

. 0

. 0

. 0

. 0 TOTAL

.0 152.0 554.0 642.0 511.0 185.0 106.0 2150.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 122.00 112.00 10 2150 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-28

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS - APR/MAY/JUN 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD [Year/Month/Day/Hour)

[2002/ 4/ 1/ 0]

TO

[2002/ 6/30/23)

PASQUILL STABILITY:

A WIND SPEED (MPH)

WIND FROM N

NNE NE ENE

.60 -

CALMS 3.50 E

ESE SE SSE

.5

.2

.3

.2

.0

.0

.0

.5

.6

.3

.2

.0

.0

.2

.8

.3 3.5 1.0 2.0 1.0

.0

.0

.0 3.0 4.0 2.0 1.0

.0 1.0

1. 0 5.0 2.0 3.50 -

7.50 28.0 5.0 1.0

.0 1.0 1.0

1. 0 33.0 64.0 10.0 9.0 6.0 8.0
17. 0 23.0 16.0 4.0 4.0

.0

.0

.0

.0

.0 3.0 12.0 5.0 4.0 2.0 1.0 18.0 16.0 3.0 7.50 -

12.50 -

18.50 -

12.50 18.50 24.00 24.00 -

80.00

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

. 0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 TOTAL 35.5 10.2 3.3 1.2

. 0 1.0 1.0 39.5 80.6 17.3 14.2 8.0 9.0 36.2 44.8 21.3 S

SSW SW WSW W

WNW NW NNW TOTAL 4.0 25.0 222.0 72.0

.0

.0

.0 323.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 10.00 50.90 131 2053 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-29

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS - APR/MAY/JUN 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 {M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/ 4/ 1/ 0]

TO

[2002/ 6/30/23)

PASQUILL STABILITY:

B WIND SPEED (MPH)

WIND FROM

.60 -

3.50 3.50 -

7.50 7.50 -

12.50 -

18.50 -

12.50 18.50 24.00 24.00 -

80.00 N

NNE NE ENE E

ESE SE SSE CALMS

_ ___.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0.0

1. 0

.0 1.0

.0 1.0 4.0 4.0 1.0

4. 0
4. 0 1.0 2.0

.0 1.0

.0

2. 0 9.0 12.0

.0

. 0 3.0

.0

.0 3.0 28.0

14. 0 5.0 2.0
4. 0
5. 0 6.0 7.0 3.0 2.0

.0

.0

.0

.0

.0 1.0 2.0 1.0 3.0

.0 2.0 5.0 2.0

. 0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

. 0 TOTAL 13.0 14.0

.0 1.0 1.0

.0

. 0 5.0 34.0 19.0 9.0 2.0 6.0 11.0 8.0 9.0 S

SSW SW WSW W

WNW NW NNW TOTAL

.0 15.0 95.0 21.0

.0

.0

.0 131.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 10.00 50.90 131 2053 NOTE: CALMS WERE DISTRIBUTED IN PROPORTtON TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-30

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

APR/MAY/JUN 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/ 4/ 1/ 0]

TO

[2002/ 6/30/23]

PASQUILL STABILITY:

C WIND SPEED (MPH)

WIND FROM

.60 3.50 3.50 -

7.50 7.50 -

12.50 -

12.50 18.50 18.50 -

24.00 24.00 -

80.00 CALMS TOTAL N

NNE NE ENE E

ESE SE SSE

. 0

. 0

. 0

. 0

.0

.0

. 0

. 0

.0

.0

.0

. 0

.0

.0

. 0

. 0 2.0 1.0 2.0 1.0 1.0

.0

.0 2.0 6.0 1.0

1. 0 2.0 1.0 1.0 1.0 1.0 13.0 11.0 4.0

.0 9.0

.0

.0 9.0 24.0 10.0 3.0 3.0 3.0 5.0 5.0 2.0 3.0

.0

.0 1.0

. 0 2.0 1.0 4.0 1.0

1. 0
1. 0
2. 0
1. 0 4.0

.0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

.0

.0

.0

.0

.0

.0

.0

. 0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 17.0 15.0 6.0

1. 0
1. 0

.0

.0 11.0 30.0

12. 0 5.0 6.0 6.0 5.0 10.0 6.0 S

SSW SW WSW W

WNW NW NNW TOTAL

.0 23.0 93.0 15.0

.0

.0

.0 131.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 10.00 50.90 131 2053 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-31

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS - APR/MAY/JUN 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/ 4/ 1/ 0)

TO

[2002/ 6/30/23]

PASQUILL STABILITY:

D WIND SPEED (MPH)

WIND FROM

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

3.50 7.50 12.50 18.50 24.00 80.00 CALMS TOTAL N

NNE NE ENE

. 0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

.0 10.0 24.0 21.0 23.0 27.0 20.0 17.0 33.0 16.0 20.0 13.0 6.0 4.0 3.0 4.0 10.0 57.0 70.0 15.0 6.0 1.0

.0 2.0 38.0

75. 0 17.0
12. 0 8.0 15.0 21.0 41.0 56.0 6.0 31.0

.0

.0

.0

.0

.0 5.0 10.0 13.0 1.0

.0 1.0 2.0 6.0 14.0

1. 0
1. 0

.0

.0

.0

. 0

.0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

. 0

.0

.0

74. 0 126.0 36.0 29.0 28.0 20.0 19.0 76.0 101.0 50.0 26.0
14. 0 20.0 26.0 51.0 80.0 S

SSW SW WSW

.0

. 0

. 0

. 0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0 251.0 434.0 89.0 2.0

.0

.0 776.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 10.00 50.90 131 2053 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-32

NL-03-068 May, 2003 Re: Indian Point Unit Nos. l & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - APR/MAY/JUN 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD [Year/Month/Day/Hour)

[2002/

4/ 1/

0]

TO

[2002/ 6/30/23)

PASQUILL STABILITY:

E WIND SPEED (MPH)

WIND FROM

.60 CALMS 3.50 N

NNE NE ENE

. 1

. 1

. 1

. 1 E

ESE SE SSE

. 0

. 0

.1I

.1 20.0 29.0 21.0

17. 0
11. 0 15.0 17.0 44.0 55.0 25.0 16.0 18.0 5.0 6.0 9.0 10.0 3.50 -

7.50 7.0 40.0 19.0 3.0 3.0

.0

.0 21.0 47.0 20.0 1.0 6.0 11.0 6.0 5.0 4.0 7.50 -

12.50

12. 50 -
18. 50

.0

. 0

. 0

. 0 2.0

.0

.0 1.0 2.0 1.0

.0

. 0

.0

.0

.0

.0

. 0

.0

.0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

.0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

.0

.0

.0

.0

. 0

. 0

.0

.0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0 18.50 -

24.00 24.00 -

80.00 TOTAL 27.1 69.1 40.1 20.1 14.0 15.0 17.1 66.1 104.2 46.1 17.1 24.1 16.0 12.0 14.0 14.0 S

SSW SW WSW

.2

.1

.1

.1I W

WNW NW NNW

.0

. 0

. 0

.0 TOTAL 1.0 318.0 193.0 4.0

.0

.0

.0 516.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 10.00

50. 90 131 2053 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-33

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

APR/MAY/JUN 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/ 4/ 1/ 0]

TO

[2002/ 6/30/23)

PASQUILL STABILITY:

F WIND SPEED (MPH)

WIND FROM

.60 -

CALMS 3.50 3.50 -

7.50 7.50 -

12.50 12.50 -

18.50 18.50 -

24.00 24.00 -

80.00 N

NNE NE ENE

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

.0 24.0 10.0 10.0 6.0 7.0 1.0 4.0 11.0 7.0 10.0 4.0 9.0 1.0 2.0 2.0 6.0

.0 12.0

9. 0 2.0

.0

.0

.0

.0 2.0 1.0

.0

.0

.0

. 0

.0 1.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

. 0

.0

.0 TOTAL 24.0 22.0 19.0 8.0 7.0 1.0 4.0 11.0

9. 0 11.0 4.0 9.0 1.0 2.0 2.0 7.0 S

SSW SW WSW

.0

.0

.0

.0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0 114.0 27.0

.0

.0

. 0

.0 141.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 10.00

50. 90 131 2053 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-34

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

APR/MAY/JUN 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/ 4/ 1/ 0]

TO

[2002/ 6/30/23]

PASQUILL STABILITY:

G WIND SPEED (MPH)

WIND FROM N

NNE NE ENE CALMS

.0

.0

.0

.0

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

3.50 7.50 12.50 18.50 24.00 80.00 E

ESE SE SSE

. 0

. 0

. 0

. 0 8.0 7.0 3.0 4.0 2.0 1.0 2.0

.0

. 0

.0 1.0

.0 2.0 3.0

2. 0 3.0
2. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0 TOTAL 10.0 7.0 3.0 4.0 2.0 1.0 2.0

.0

.0

.0 1.0

.0

.0

.0 2.0 3.0 S

SSW SW WSW

. 0

. 0

. 0

.0 W

WNW NW NNW

.0

. 0

. 0

. 0 TOTAL

.0 33.0 2.0

.0

.0

.0

.0 35.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 10.00 50.90 131 2053 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-35

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS

- APR/MAY/JUN 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD [Year/Month/Day/Hour)

[2002/ 4/ 1/ 0]

TO

[2002/ 6/30/23)

PASQUILL STABILITY:

ALL WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 N

NNE NE ENE

. 5

. 3

.4

. 2 E

ESE SE SSE

. 0

. 0

. 1

. 6 68.0 72.0 59.0 52.0 49.0 37.0 40.0

94. 0
92. 0 62.0 37.0 35.0 11.0
14. 0 23.0 34.0 116.0 150.0 48.0 11.0 4.0 1.0 3.0 104.0 240.0 72.0 30.0 25.0 41.0
52. 0 80.0 89.0 15.0 40.0

.0

.0

.0

.0

.0 10.0 26.0 21.0

9. 0 3.0 6.0 26.0 28.0
17. 0
1. 0
1. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0 TOTAL 200.5 263.3 107.4 63.2 53.0 38.0 43.1 208.6 358.8 155.4 76.2 63.1 58.0 92.2 131.8 140.4 S

SSW SW WSW

. 8

.4

.2

.1I W

WNW NW NNW

. 0

. 2

. 8

. 4 TOTAL 5.0 779.0 1066.0 201.0 2.0

.0

.0 2053.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 10.00 50.90 131 2053 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-36

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

APR/MAY/JUN 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/ 4/ 1/ 0]

TO

[2002/ 6/30/23)

PASQUILL STABILITY:

A WIND SPEED (MPH)

WIND FROM

.60 -

3.50 3.50 -

7.50 7.50 -

12.50 -

18.50 -

24.00 -

12.50 18.50 24.00 80.00 CALMS TOTAL N

NNE NE ENE

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

.0 1.0 1.0 2.0

.0

.0

.0 1.0 1.0

.0

. 0

. 0

.0

. 0 1.0

1. 0
1. 0 3.0 1.0 1.0

.0

.0

.0

.0 34.0 16.0 3.0 3.0 3.0

.0

.0 1.0 2.0

14. 0 1.0 1.0

.0

.0 1.0 2.0 53. 0 13.0 2.0 2.0 5.0.

9.0 11.0 13.0 12.0 14.0 1.0

.0

.0 4.0 7.0 2.0

4. 0 7.0 2.0
3. 0
2. 0 4.0 11.0 24.0 10.0 1.0

.0

.0

.0

.0

.0

. 0

. 0

.0 2.0 5.0

1. 0

.0 4.0 14.0 1.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 1.0

.0

.0 7.0 9.0

. 0 33.0 4.0 4.0

.0

.0 1.0 2.0 92.0 36.0 9.0

14. 0 11.0 13.0 33.0 62.0 26.0 S

SSW SW WSW

.0

.0

.0

.0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0 7.0 67.0 139.0 82.0 28.0 17.0 340.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 60.00 50.90 9

2175 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-37

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS - APR/MAY/JUN 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/ 4/ 1/ 0)

TO

[2002/ 6/30/23]

PASQUILL STABILITY:

B WIND SPEED (MPH)

WIND FROM

.60 3.50 3.50 -

7.50 -

12.50 -

18.50 -

24.00 CALMS 7.50 N

NNE NE ENE

.0

. 0

.0

. 0 E

ESE SE SSE

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

.0 2.0 1.0

.0

.0

.0

.0

.0

.0 1.0 4.0 3.0

.0

.0

.0

.0

.0 13.0 25.0 10.0 3.0 2.0 1.0 2.0 2.0 12.50 18.50 24.00 80.00 TOTAL 8.0____

4.0---- ----

0--

1.0----

17.0---

8.0 4.0

.0 1.0 17.0 6.0

.0

.0

.0 1.0 1.0

.0

.0

.0 1.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 5.0 2.0

.0

.0 22.0 2.0

.0

.0

.0 28.0 1.0 3.0 2.0

.0 16.0 2.0 1.0

.0 1.0 7.0

.0 1.0 1.0

.0 4.0 1.0 2.0 1.0

.0 5.0 1.0 1.0 4.0 1.0 10.0 3.0 6.0 2.0 2.0 15.0 4.0 1.0

.0

.0 8.0 S

SSW SW WSW

. 0

. 0

. 0

. 0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0 4.0 68.0 34.0 21.0 10.0 5.0 142.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS.

DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 60.00 50.90 9

2175 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-38

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

APR/MAY/JUN 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M)

FOR PERIOD [Year/Month/Day/Hour)

[2002/ 4/ 1/ 0]

TO

[2002/ 6/30/23]

PASQUILL STABILITY:

C WIND SPEED (MPH)

WIND FROM CALMS

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

3.50 7.50 12.50 18.50 24.00 N

NNE NE ENE

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

.0

.0 1.0 1.0

.0

.0

.0

.0 1. 0 3.0

.0

.0

.0

.0

.0

.0 5.0 4.0 3.0 1.0

.0 1.0

.0 10.0 20.0 5.0 1.0 3.0 2.0 3.0 1.0 4.0 7.0 10.0 1.0

. 0

.0

.0

.0 9.0 7.0 1.0 1.0 2.0 4.0 1.0 3.0 4.0 3.0

.0

.0

.0

.0

.0

. 0 3.0

.0 1.0

.0

.0

1. 0 1.0 4.0 1.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

1. 0 1.0 1.0 1.0 2.0 3.0

. 0 24.00 -

80.00 1.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0 TOTAL 16.0 15.0 4.0 1.0

.0 1.0

.0 23.0 30.0 8.0 3.0 6.0 8.0 8.0 11.0 9.0 S

SSW SW WSW

.0

.0

.0

.0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0 6.0 63.0 50.0 14.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 9.0 60.00 50.90 9

2175 1.0 143.0 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-39

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - APR/MAY/JUN 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M)

FOR PERIOD [Year/Month/Day/Hour)

[2002/ 4/ 1/ 0]

TO

[2002/ 6/30/23]

PASQUILL STABILITY:

D WIND SPEED (MPH)

WIND FROM

.60 3.50 3.50 -

7.50 -

12.50 -

18.50 -

7.50 12.50 18.50 24.00 24.00 -

80.00 CALMS TOTAL N

NNE NE ENE

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

.0 3.0 3.0 5.0 5.0 6.0 5.0 6.0 9.0 11.0 6.0 4.0 1.0 1.0

.0

. 0 4.0 14.0 34.0 24.0 23.0 19.0 17.0 26.0 32.0 39.0 9.0 5.0 2.0 3.0 2.0 3.0 6.0 31.0 22.0 6.0 6.0 6.0

.0

. 0 58.0 22.0 7.0 6.0 3.0 7.0 3.0 14.0 32.0

34. 0 7.0

.0

.0

.0

.0

.0 26.0 8.0 10.0

10. 0 7.0 8.0 17.0
52. 0 43.0 2.0 1.0

.0

.0 1.0 1.0 2.0

.0

1. 0
1. 0 2.0 5.0 2.0 5.0 7.0 16.0 3.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 2.0 1.0 87.0 67.0 35.0 34.0 31.0 22.0 32.0 125.0 81.0 33.0 27.0

13. 0 21.0 27.0 78.0 102.0 S

SSW SW WSW

.0

.0

.0

.0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0 69.0 258.0 223.0 222.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 37.0 60.00 50.90 9

2175 6.0 815.0 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-40

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

APR/MAY/JUN 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/ 4/ 1/ 0]

TO

[2002/ 6/30/23]

PASQUILL STABILITY:

E WIND SPEED (MPH)

WIND FROM N

NNE NE ENE

.60 -

3.50 -

7.50 -

12.50 -

CALMS 3.50 7.50 12.50 18.50

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

.0 4.0 11.0 4.0 3.0 6.0 5.0 6.0 10.0 9.0 11.0 5.0 5.0 4.0 2.0 2.0 3.0 15.0 47.0 12.0 8.0 4.0 4.0 10.0 37.0 41.0 27.0 7.0 2.0 3.0 5.0 5.0 5.0 8.0 27.0 1.0 1.0

.0

.0 1.0 49.0 29.0 18.0 11.0 3.0 10.0 14.0 10.0 2.0

.0

.0

.0

.0

.0

.0

.0 2.0 5.0 3.0 4.0

.0 3.0 6.0 11.0 2.0 18.50 -

24.00

.0

.0

.0

.0

.0

.0

.0

.0 1.0

.0

.0 1.0

.0

.0

.0

.0 24.00 -

80.00

_ ___.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0 1.0

1. 0

. 0 TOTAL 27.0 85.0 17.0 12.0 10.0 9.0 17.0 98.0 85.0 59.0 27.0 11.0 20.0 27.0 29.0 12.0 S

SSW SW WSW

.0

.0

.0

.0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0 90.0 232.0 184.0 36.0 2.0 1.0 545.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 60.00 50.90 9

2175 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-41

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

APR/MAY/JUN 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 {M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/ 4/ 1/ 0]

TO

[2002/ 6/30/23]

PASQUILL STABILITY:

F WIND SPEED (MPH)

WIND FROM

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

NNE NE ENE

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

.0 7.0 6.0 4.0

.0

1. 0
1. 0 2.0 1.0 3.0 1.0 4.0 2.0 4.0 6.0

.0 3.0

12. 0 16.0 3.0 1.0 1.0 1.0
1. 0 6.0 8.0 8.0 5.0 2.0 1.0 1.0 1.0

.0 5.0 6.0

.0

.0 4.0 3.0 5.0 1.0 4.0 3.0 5.0 1.0

2. 0 7.0
2. 0

.0 1.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0 1.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 25.0 28.0 7.0 1.0 1.0 2.0 3.0 8.0 15.0

12. 0
14. 0 5.0 8.0 14.0 3.0 3.0 S

SSW SW WSW

.0

.0

.0

.0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0 45.0 66.0 36.0 2.0

.0

.0 149.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 60.00 50.90 9

2175 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-42

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS - APR/MAY/JUN 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M)

FOR PERIOD [Year/Month/Day/Hour)

[2002/ 4/ 1/ 0]

TO

[2002/ 6/30/23]

PASQUILL STABILITY:

G WIND SPEED (MPH)

WIND FROM

.60 -

CALMS 3.50 3.50 -

7.50 -

12.50 -

18.50 -

7.50 12.50 18.50 24.00 24.00 -

80.00 N

NNE NE ENE E

ESE SE SSE

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 2.0 2.0 2.0 1.0 1.0 1.0 3.0 4.0

.0 2.0 3.0 2.0

.0 2.0 2.0 2.0 3.0 4.0

.0 2.0

.0

.0

..0

2. 0 1.0

.0

.0

.0 2.0

.0

.0

.0

.0

.0

.0

. 0

.0 1.0

. 0

.0

.0

.0

1. 0

.0

.0

.0

1. 0
1. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

. 0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

. 0

.0

.0

.0

.0

.0

.0 TOTAL 5.0 6.0 2.0 1.0

.0 1.0 3.0 6.0 1.0 2.0 4.0 2.0 2.0

.0 3.0 3.0 S

SSW SW WSW W

WNW NW NNW TOTAL

.0 26.0 12.0 3.0

.0

.0

.0 41.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS.

DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER.

DURING THIS PERIOD (ALL STABILITIES) 60.00 50.90 9

2175 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E43

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - APR/MAY/JUN 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M)

FOR PERIOD [Year/Month/Day/Hour)

[2002/ 4/ 1/ 0)

TO

[2002/ 6/30/23]

PASQUILL STABILITY: ALL WIND SPEED (MPH)

WIND FROM

.60 -

3.50 3.50 -

7.50 7.50 -

12.50 12.50 -

18.50 18.50 -

24.00 24.00 -

80.00 CALMS TOTAL N

NNE NE ENE

. 0

.0

. 0

. 0 E

ESE SE SSE

. 0

.0

. 0

. 0 17.0 24.0 17.0 9.0 13.0 12.0 17.0 28.0 27.0 20.0 16.0

10. 0
9. 0 9.0 5.0 14.0 56.0 109. 0 43.0 33.0 23.0 23.0 37.0 134.0 150.0 62.0 24.0 14.0
12. 0
14. 0 13.0 19.0 73. 0
72. 0 10.0 7.0 6.0 1.0 3.0 175.0 77.0 32.0 28.0
14. 0 33.0 37.0 46.0 55.0 56.0 8.0

.0

.0

.0

.0

.0 37.0 20.0 19.0 18.0 10.0 19.0 36.0 97.0 57.0 3.0 1.0

.0

.0 2.0 6.0 8.0 4.0 2.0

6. 0 8.0
4. 0
4. 0 15.0 26.0 17.0 5.0

.0

.0 2.0

.0 8.0

.0 1.0

.0

.0

2. 0

.0

.0

8. 0 14. 0
1. 0 210.0 214.0 70.0 49.0 42.0 36.0 57.0 374.0 276.0 139.0 96.0 52.0 77.0 119. 0 201.0 163.0 S

SSW SW WSW

. 0

.0

. 0

. 0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0 247.0 766.0 669.0 377.0 86.0 30.0 2175.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 60.00 50.90 9

2175 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-44

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

APR/MAY/JUN 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/ 4/ 1/ 03 TO

[2002/ 6/30/23]

PASQUILL STABILITY:

A WIND SPEED (MPH)

WIND FROM

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

CALMS 3.50 7.50 12.50 18.50 24.00 24.00 -

80.00 N

NNE NE ENE

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 1.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 2.0 4.0

.0

.0

.0

.0 1.0 1.0 1.0

1. 0

.0

.0

. 0

.0

.0

.0 1.0 3.0

.0

.0

.0

. 0 1.0 6.0 3.0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0 3.0

1. 0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

. 0

.0

.0

.0

.0

.0

.0

.0 TOTAL

_ ___.0

.0

.0

. 0

.0 3.0 3.0 7.0

. 0 1.0

.0

.0 2.0 10.0 5.0 1.0

.0 S

SSW SW WSW

.0

.0

.0

.0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0

.0 1.0 10.0 14.0 4.0

.0 29.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 122.00 112.00 9

2175 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E45

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

APR/MAY/JUN 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/ 4/ 1/ 0)

TO

[2002/ 6/30/23]

PASQUILL STABILITY:

B WIND SPEED (MPH)

WIND FROM

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

3.50 7.50 12.50 18.50 24.00 80.00 CALMS TOTAL N

NNE NE ENE

.0

.0

.0

.0 E

ESE SE SSE

. 0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 7.0

. 0 7.0 1.0 1.0

.0

.0

.0

.0

.0

.0

.0

1. 0

.0

.0

.0

.0

.0 20.0 2.0

.0 1.0 1.0

1. 0 2.0 4.0 5.0 2.0
2. 0

.0

.0

.0

.0 4.0 4.0 3.0 2.0 4.0

2. 0
4. 0 5.0 7.0 5.0 7.0

. 0 1.0

.0

.0 4.0 4.0

1. 0
1. 0
2. 0

.0

1. 0

.0 4.0 4.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

9. 0
8. 0

.0

.0 3.0

.0

.0

.0

.0

.0 32.0 7.0 3.0

. 0 4.0 5.0 20.0 23.0 10.0 9.0 S

SSW SW WSW

. 0

.0

. 0

. 0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0

.0 9.0 38.0 39.0 13.0 17.0 116.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS.

DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 122.00 112.00 9

2175 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY.

OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-46

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS - APR/MAY/JUN 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/ 4/ 1/ 0]

TO

[2002/ 6/30/23J PASQUILL STABILITY:

C WIND SPEED (MPH)

WIND FROM N

NNE NE ENE

.60 -

CALMS 3.50

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

.0

.0

.0

1. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 3.50 -

7.50 1.0

.0

.0 6.0 1.0

.0 18.0 6.0

2. 0 1.0
3. 0 1.0 1.0
1. 0
1. 0
2. 0 7.50 -

12.50 10.0---

10.0 1.0

.0 1.0 1.0 5.0 15.0 1.0 1.0 2.0 2.0 4.0 4.0 4.0

12. 0 12.50 -

18.50 1.0 1.0

.0

.0

.0

.0 5.0 3.0 3.0 3.0 3.0 2.0 3.0 11.0 10.0 11.0 18.50 -

24.00

_ ___.0

.0

. 0

.0

.0

.0 1.0 1.0 2.0

2. 0 4.0

.0 2.0 4.0 8.0 2.0 1.0 24.00 -

80.00

.0

.0

.0

.0

.0

.0

.0

.0 3.0 3.0

.0

. 0 4.0 4.0 2.0

2. 0 TOTAL 11.0 2.0 1.0

.0 2.0

.0 39.0 10.0 8.0 12.0 8.0 8.0 15.0 28.0 17.0 28.0 S

SSW SW WSW

.0

.0

.0

.0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0 1.0 35.0 60.0 56.0 24.0 13.0 189.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 122.00 112.00 9

2175 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-47

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

APR/MAY/JUN 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M)

FOR PERIOD [Year/Month/Day/Hour)

[2002/ 4/ 1/ 0]

TO

[2002/ 6/30/23)

PASQUILL STABILITY:

D WIND SPEED (MPH)

WIND FROM CALMS

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

3.50 7.50 12.50 18.50.

24.00 N

NNE NE ENE

.0

.0

. 0

.0 E

ESE SE SSE

.0

.0

.0

.0 6.0 6.0 4.0 4.0 3.0 4.0 11.0 10.0 2.0 1.0 3.0 2.0 3.0 1.0

1. 0 22.0 24.0 17.0
12. 0
12. 0 21.0 82.0 64.0 17.0 7.0 10.0 6.0 3.0 10.0 9.0 19.0 39.0 8.0
12. 0 18.0 15.0 8.0 64.0 40.0 8.0 5.0 7.0 9.0
12. 0
24. 0 23.0 41.0
12. 0 2.0 1.0

.0

. 0

. 0 61.0 19.0 8.0 16.0

11. 0 10.0 23.0 65.0 44.0 34.0 3.0

.0

.0

.0

.0

.0 3.0 1.0 11.0 7.0 5.0 12.0 10.0 31.0 13.0 15.0 24.00 -

80.00

_ ___.0

.0

.0

.0

.0

.0 1.0 1.0 1.0 1.0 1.0 3.0 3.0 9.0

9. 0 4.0 5.0 TOTAL 82.0 40.0
34. 0 34.0 30.0 33.0 222.0 134.0 47.0 37.0 36.0 42.0 57.0 139.0 96.0 115.0 S

SSW SW WSW

.0

.0

.0

.0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0 60.0 335.0 333.0 306.0 111.0 33.0 1178.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 122.00 112.00 9

2175 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-48

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

APR/MAY/JUN 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/ 4/ I/ 0]

TO

[2002/ 6/30/23]

PASQUILL STABILITY:

E WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 24.00 -

80.00 N

NNE NE ENE

. 0

. 0

. 0

. 0 E

ESE SE SSE

. 0

. 0

. 0

. 0 5.0 2.0 5.0 2.0 7.0 5.0 12.0

16. 0 9.0 6.0 5.0 3.0 2.0 4.0 2.0 2.0 15.0 6.0 2.0 4.0 6.0 6.0 32.0 37.0 26.0
9. 0 7.0 4.0 6.0 2.0 6.0 12.0 18.0

.0

.0 1.0

1. 0 3.0 41.0 56.0 22.0 11.0 10.0 8.0 15.0 2.0 3.0 17.0 2.0

.0 6.0

. 0 7.0

. 0

18. 0
6. 0 10.0

. 0 7.0

10. 0
4. 0
1. 0 4.0

.0

.0

.0

.0

.0

.0 1.0 3.0 1.0

.0

.0 2.0 1.0

.0 1.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 TOTAL 40.0 8.0 7.0 6.0 14.0 14.0 104.0 115.0

64. 0 36.0 22.0 24.0 34.0 12.0 13.0 35.0 S

SSW SW WSW

. 0

. 0

. 0

. 0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0 87.0 180.0 207.0 65.0 9.0

.0 548.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 122.00 112.00 9

2175 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-49

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS - APR/MAY/JUN 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M)

FOR PERIOD (Year/Month/Day/Hour)

[2002/ 4/ 1/ 0]

TO

[2002/ 6/30/23]

PASQUILL STABILITY:

F WIND SPEED (MPH)

WIND FROM

.60 3.50 3.50 -

7.50 7.50 -

12.50 12.50 -

18.50 18.50 -

24.00 24.00 -

80.00 CALMS TOTAL N

NNE NE ENE

. 0

. 0

. 0

.0 E

ESE SE SSE

. 0

.0

. 0

.0 1.0 1.0

.0

.0

.0 3.0 7.0 3.0 3.0 2.0

.0

.0 1.0

.0 1.0 1.0 8.0 1.0 1.0

.0

.0

.0 11.0 6.0 4.0 3.0 2.0

1. 0 3.0 3.0 4.0 6.0

.0

.0

.0 3.0 2.0 1.0 3.0 2.0 31.0 2.0

1. 0
3. 0

.0

2. 0
12. 0
2. 0

.0

.0

.0 4.0

.0 1.0

.0

.0

.0

.0

.0

.0

4. 0
1. 0

.0

1. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 9.0 2.0 1.0

.0

.0 3.0 18.0 9.0

10. 0 7.0 3.0 4.0 8.0 6.0 17.0 10.0 S

SSW SW WSW

.0

.0

.0

.0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0 23.0 53.0 25.0 6.0

.0

.0 107.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 122.00 112.00 9

2175 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-50

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS - APR/MAY/JUN 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M)

FOR PERIOD [Year/Month/Day/Hour)

[2002/ 4/ 1/ 01 TO

[2002/ 6/30/23)

PASQUILL STABILITY:

G WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 24.00 -

80.00 TOTAL N

NNE NE ENE

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

. 0 1.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0 1.0 1.0 2.0 1.0 1.0

. 0

1. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0 1.0

. 0

.0

.0

1. 0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

1. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0 S

SSW SW WSW

.0

. 0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0 1.0 2.0

.0 3.0

.0 2.0

.0

. 0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0 1.0 5.0 1.0 1.0

.0

.0 8.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 122.00 112.00 9

2175 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-51

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - APR/MAY/JUN 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M)

FOR PERIOD [Year/Month/Day/Hour)

[2002/ 4/ 1/ 0]

TO

[2002/ 6/30/23]

PASQUILL STABILITY: ALL WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

NNE NE ENE

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

.0 12.0 9.0 10.0 6.0

10. 0
12. 0 30.0 29.0
14. 0 9.0 8.0 6.0 3.0 4.0 6.0 4.0 45.0 31.0 20.0 16.0 19.0 27.0 150.0 114.0 52.0 21.0 22.0
12. 0 13.0 17.0 20.0 39.0 68.0 9.0 12.0 18.0 17.0 13. 0 144.0 99.0 34.0 20.0 21.0 27.0 33.0 37.0 48.0
74. 0
17. 0 3.0 1.0

.0

.0 1.0 91.0 28.0 17.0 29.0 16.0 24.0 51.0 92.0 60.0 57.0 3.0

.0

.0

.0

.0

.0 6.0 5.0 16.0 11.0 6.0 16.0 22.0 44.0 16.0 16.0

.0

.0

.0

.0

.0

.0 1.0

.0

1. 0 4.0

. 0 3.0 22.0 21.0 4.0 7.0 145.0 52.0 43.0 40.0 46.0 53.0 422.0 275.0 134.0 94.0 73.0 88.0 144. 0 215.0 154.0 197.0 S

SSW SW WSW

.0

.0

.0

.0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0 172.0 618.0 674.0 487.0 161.0 63.0 2175.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS.

DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 122.00 112.00 9

2175 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-52

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

JUL/AUG/SEP 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/ 7/ 1/ 0]

TO

[2002/ 9/30/23]

PASQUILL STABILITY:

A WIND SPEED (MPH)

WIND FROM

.60 -

3.50 3.50 -

7.50 7.50 -

12.50 -

18.50 -

24.00 -

12.50 18.50 24.00 80.00 CALMS TOTAL N

NNE NE ENE

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 4.0 4.0

.0 1.0 1.0 1.0 1.0

.0

.0 54.0 7.0

.0

.0 1.0 1.0 3.0 25.0 92.0 7.0 6.0 22.0 10.0 2.0 2.0 13. 0 29.0 14.0

.0

.0

.0

.0 4.0 3.0 4.0 3.0

.0

.0

.0

.0 5.0

5. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 83.0 21.0

.0

.0

.0 1.0 3.0 29.0 100.0 10.0 7.0 23.0 11.0 3.0 2.0 18.0 S

SSW SW WSW

.0

.0

.0

.0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0 12.0 244.0 55.0

.0

.0

.0 311.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 10.00 50.90 0

22 08 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-53

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

JUL/AUG/SEP 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD [Year/Month/Day/Hour)

[2002/ 7/ 1/ 0]

TO

[2002/ 9/30/23]

PASQUILL STABILITY:

B WIND SPEED (MPH)

WIND FROM

.60 -

CALMS 3.50 3.50 -

7.50 -

12.50 -

18.50 -

7.50 12.50 18.50 24.00 24.00 -

80.00 N

NNE NE ENE E

ESE SE SSE

. 0

. 0

. 0

. 0

. 0

. 0

.0

.0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0 2.0

.0

.0

.0 3.0 1.0 2.0 1.0

12. 0
3. 0 1.0 2.0

. 0

1. 0
1. 0

. 0 33.0 11.0 1.0

.0 2.0 1.0

.0 3.0 25.0 11.0 1.0 7.0 2.0

1. 0
1. 0 1.0 8.0 5.0

.0

.0

. 0

. 0 1.0

.0 1.0

1. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

. 0

. 0

.0

.0

.0

.0 TOTAL 43.0 16.0 1.0

.0 2.0 1.0

.0 3.0 38.0 15.0 2.0 9.0 2.0 2.0 2.0 1.0 S

SSW SW WSW W

WNW NW NNW TOTAL

.0 22.0 100.0 15.0

. 0

.0

.0 137.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 10.00 50.90 0

2208 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-54

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS JUL/AUG/SEP 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD [Year/Month/Day/Hour)

[2002/ 7/ 1/ 0]

TO

[2002/ 9/30/23)

PASQUILL STABILITY:

C WIND SPEED (MPH)

WIND FROM

.60 -

3.50 -

CALMS 3.50 7.50 7.50 -

12.50 12.50 -

18. 50 18.50 -

24.00 24.00 -

80.00 N

NNE NE ENE

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

.0 3.0 5.0

. 0 1.0

.0 1.0 1.0 6.0 13.0 3.0 1.0 2.0 2.0 1.0

.0

.0 20.0 18.0 10.0 3.0

.0 6.0 2.0 3.0 14. 0 6.0 2.0 1.0 2.0

1. 0
2. 0 5.0
7. 0

.0

.0 1.0 2.0

.0

.0 1.0

2. 0

.0

.0

.0

.0

.0

1. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

. 0

. 0

. 0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0 TOTAL 28.0 30.0 10.0 4.0

.0

.0 1.0 6.0 28.0

11. 0 3.0 5.0 2.0 1.0 1.0 3.0 S

SSW SW WSW

.0

.0

.0

.0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0 38.0 79.0 16.0

.0

.0

.0 133.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 10.00 50.90 0

2208 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-55

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

JUL/AUG/SEP 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/ 7/ 1/ 0]

TO

[2002/ 9/30/23]

PASQUILL STABILITY:

D WIND SPEED (MPH)

WIND FROM

.60 -

CALMS 3.50 3.50 -

7.50 -

12.50 -

18.50 -

7.50 12.50 18.50 24.00 24.00 -

80.00 N

NNE NE ENE E

ESE SE SSE

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 11.0 20.0 15.0 20.0

17. 0
10. 0 8.0 20.0 32.0 15.0 7.0 6.0 1.0 4.0 3.0 3.0
84. 0 159.0 35.0 10.0

.0

.0 3.0

3. 0
94. 0 28.0
10. 0 8.0 4.0 1.0 4.0 8.0 19.0 59.0

.0

.0

.0 1.0 4.0

.0 4.0 5.0

.0

.0

.0

.0

.0

2. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 TOTAL 114.0 238. 0 50.0 30.0 17.0 11.0 8.0 23.0 130.0 48.0 17.0

14. 0 5.0 5.0 7.0 13.0 S

SSW SW WSW W

WNW NW NNW TOTAL

.0 192.0 448.0 90.0

.0

.0

.0 730.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 10.00 50.90 0

2208 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-56

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

JUL/AUG/SEP 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/ 7/ 1/ 0)

TO

[2002/ 9/30/23)

PASQUILL STABILITY:

E WIND SPEED (MPH)

WIND FROM CALMS

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

3.50 7.50 12.50 18.50 24.00 24.00 -

80.00 N

NNE NE ENE

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

. 0 20.0 62.0 42.0 21.0 25.0 20.0 21.0 28.0 70.0 36.0 24.0 16.0 10.0 9.0 9.0 13.0 9.0 89.0 39.0 3.0 2.0

.0

.0 5.0 55.0 26.0 3.0 2.0 1.0 2.0 1.0

. 0

. 0

2. 0

.0

.0 4.0 2.0

. 0

. 0 4.0 2.0

.0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

.0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

. 0

. 0

.0

.0 TOTAL 29.0 153.0 81.0 24.0 27.0 20.0 21.0 33.0 129.0 64.0 27.0 18.0 11.0 11.0 10.0 13.0 S

SSW SW WSW

. 0

.0

. 0

. 0 W

WNW NW NNW

.0

.0

.0

. 0 TOTAL

.0 426.0 237.0 8.0

.0

.0

.0 671.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 10.00 50.90 0

2208 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-57

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - JUL/AUG/SEP 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/ 7/ 1/ 0]

TO

[2002/ 9/30/23)

PASQUILL STABILITY:

F WIND SPEED (MPH)

WIND FROM

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

3.50 7.50 12.50 18.50 24.00 80.00 CALMS TOTAL N

NNE NE ENE

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

.0 19.0 60.0 15.0 7.0 8.0 7.0 4.0 3.0 10.0 8.0 5.0 2.0 2.0 4.0 3.0 8.0

.0 3 6. 0

14. 0 1.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0 1.0 1.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

. 0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 20.0 97.0 29.0 8.0 8.0 7.0 4.0 3.0 10.0 8.0 5.0 2.0 2.0 4.0 3.0 8.0 S

SSW SW WSW

.0

.0

.0

.0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0 165.0 51.0 2.0

.0

.0

.0 218.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 10.00 50.90 0

2208 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-58

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

JUL/AUG/SEP 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/ 7/ 1/ 0]

TO

[2002/ 9/30/23]

PASQUILL STABILITY:

G WIND SPEED (MPH)

WIND FROM

.60 -

3.50 3.50 -

7.50 7.50 -

12.50 -

18.50 -

12.50 18.50 24.00 24.00 -

80.00 N

NNE NE ENE CALMS

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

.0 3.0 1.0 1.0

.0

.0

.0 2.0 2.0 1.0

.0

.0

.0

.0

.0

.0 1.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 TOTAL

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 3.0 1.0 1.0

. 0

.0

.0

.0 2.0 S

SSW SW WSW

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 W

WNW NW NNW

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

1. 0 TOTAL

.0 8.0

.0

.0

.0

. 0

.0 8.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 10.00 50.90 0

2208 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-59

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

JUL/AUG/SEP 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/ 7/ 1/ 0)

TO

[2002/ 9/30/23]

PASQUILL STABILITY: ALL WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 N

NNE NE ENE

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

.0 58.0 148. 0 73.0 49.0 50.0 37.0 34.0 63.0 141.0 65.0 39.0 29.0 16.0 20.0 16.0 25.0 200.0 320.0 99.0 17.0 4.0 2.0 3.0 36.0 280.0 78.0

22. 0
42. 0 17.0 6.0 9.0 24.0 62. 0 88.0

.0

. 0

.0 14.0

.0

.0 14. 0

13. 0

.0 8.0

.0

.0

.0

8. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0 TOTAL 320.0 556.0 172.0 66.0 54.0 40.0 37.0 99.0 435.0 156.0 61.0 71.0 33.0 26.0 25.0 57.0 S

SSW SW WSW

.0

.0

.0

.0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0 863.0 1159.0 186.0

. 0

.0

.0 2208.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 10.00 50.90 0

2208 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-60

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

JUL/AUG/SEP 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/ 7/ 1/ 0]

TO

[2002/ 9/30/23]

PASQUILL STABILITY:

A WIND SPEED (MPH)

WIND FROM

.60 -

3.50 -

3.50 7.50 7.50 -

12.50 -

12.50 18.50 CALMS N

NNE NE ENE

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

.0

.0

.0

.0

1. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 4.0

.0

.0

.0

.0

.0 1.0 58.0

14. 0 3.0

.0 3.0 1.0 3.0

.0 3.0 33.0 3.0

.0

. 0

.0 1.0 4.0 39.0 7.0 1.0 1.0 2.0 9.0

19. 0 3.0 15.0 31.0

.0

.0

.0

.0

.0

.0 7.0 3.0 4.0

. 0 2.0 2.0 1.0 7.0

10. 0 18.50 -

24.00 6.0----

6.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 1.0 1.0

.0

. 0 1.0 2.0 24.00 -

80.00

_ ___.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 2.0 2.0 4.0 TOTAL 74. 0 34.0 3.0

. 0 1.0

.0 1.0 5.0 104.0 24.0 8.0 1.0 8.0 12.0 23.0 13.0 34.0 S

SSW SW WSW

.0

.0

.0

.0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0 1.0 90.0 137.0 67.0 10.0 6.0 311.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 60.00 50.90 0

2208 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-61

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3)

JOINT FREQUENCY DISTRIBUTIONS -

JUL/AUG/SEP 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/

7/

1/

0]

TO

[2002/ 9/30/23]

PASQUILL STABILITY:

B WIND SPEED (MPH)

WIND FROM

.60 3.50 3.50 -

7.50 -

12.50 -

18.50 -

7.50 12.50 18.50 24.00 24.00 -

80.00 CALMS TOTAL N

NNE NE ENE

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0 3.0 3.0 1.0 1.0 1.0

.0

1. 0

.0

.0 1.0 8.0 2.0 1.0

.0 2.0 1.0

.0 9.0 20.0 4.0 3.0 1.0 1.0

.0

.0 2.0 20.0 2.0

.0

.0 9.0 3.0

.0 9.0 3.0 2.0

1. 0 3.0 2.0 2.0
2. 0 12.0

.0

.0

.0

.0

.0 1.0

1. 0 2.0
2. 0 1.0 3.0 4.0 3.0
4. 0
4. 0 1.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

1. 0 1.0

.0

.0

.0

.0

. 0

. 0

.0

.0

.0

.0

.0

.0

.0

.0 2.0 42.0 4.0 1.0

.0 2.0 1.0

.0 22.0

24. 0 6.0 6.0 1.0 4.0 6.0 6.0
12. 0 S

SSW SW WSW

.0

.0

.0

.0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0 7.0

54. 0 44.0 27.0 2.0 3.0 137.0 DATA MEASUREMENT HEIGHT CM ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS.

DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER.

DURING THIS PERIOD (ALL STABILITIES) 60.00 50.90 0

2208 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-62

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

JUL/AUG/SEP 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M)

FOR PERIOD [Year/Month/Day/Hour)

[2002/ 7/ 1/ 0]

TO

[2002/ 9/30/23]

PASQUILL STABILITY:

C WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 N

NNE NE ENE

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

.0 2.0

.0

1. 0

. 0

. 0

.0

.0

. 0 5.0

.0

1. 0

.0

.0

.0

.0

14. 0 4.0 6.0 2.0 2.0

. 0 2.0 12.0 16.0 2.0 1.0 1.0 2.0 2.0 2.0

2. 0 14.0 7.0 2.0 1.0 2.0

.0

.0 3.0 2.0

1. 0 1.0 1.0 1.0

.0 1.0

.0 8.0 2.0

.0

. 0

.0

.0

.0

.0

.0 3.0

.0

.0 2.0 1.0 2.0

.0 2.0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0 24.00 -

80.00

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 1.0 TOTAL 40.0 13.0 9.0 3.0 4.0

. 0 2.0 15.0 23.0 6.0 3.0 2.0 3.0 4.0 3.0 3.0 S

SSW SW WSW

.0

.0

.0

.0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0 10.0 66.0 36.0 18.0 2.0 1.0 133.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 60.00 50.90 0

2208 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-63

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

JUL/AUG/SEP 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M)

FOR PERIOD [Year/Month/Day/Hour)

[2002/ 7/ 1/ 0]

TO

[2002/ 9/30/23]

PASQUILL STABILITY:

D WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

FROM CALMS 3.50 7.50 12.50 18.50 N

NNE NE ENE

.0

.0

. 0

.0 E

ESE SE SSE

. 0

.0

.0

.0 3.0 4.0 13.0 6.0 5.0 3.0 5.0 7.0 15.0 7.0 3.0 1.0 1.0 1.0 1.0

1. 0 16.0 42.0 22.0 20.0 10.0 9.0 4.0 18.0 27.0 14.0 11.0

.0 1.0 2.0 4.0 6.0 59.0 72.0 21.0 5.0 4.0 2.0 1.0 32.0 27.0 17.0 5.0 7.0 10.0 2.0 5.0 15.0 62.0 13.0

.0 1.0 1.0

.0 5.0

5. 0
9. 0 8.0 1.0 1.0 6.0
6. 0 19.0 20.0 18.50 -

24.00 4.0

.0

.0

.0

.0 1.0

.0

.0

.0

.0

.0

.0

.0 2.0 4.0 2.0 24.00 -

80.00

.0O

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 4.0 4.0 TOTAL 144.0 131.0 56.0 31.0 20.0 15.0

10. 0
62. 0 78.0 46.0 20.0 9.0 11.0 13.0 36.0 48.0 S

SSW SW WSW

.0

.0

.0

.0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0 74.0 206.0 284.0 145.0 13.0 8.0 730.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 60.00 50.90 0

2208 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-64

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

JUL/AUG/SEP 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M)

FOR PERIOD [Year/Month/Day/Hour)

[2002/ 7/ 1/ 0]

TO

[2002/ 9/30/23)

PASQUILL STABILITY:

E WIND SPEED (MPH)

WIND FROM

.60 -

CALMS 3.50 3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

7.50 12.50 18.50 24.00 80.00 TOTAL N

NNE NE ENE E

ESE SE SSE

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 9.0 12.0 4.0 2.0 4.0 6.0 4.0 7.0 7.0 6.0 6.0 8.0 10.0 8.0 12.0 5.0 17.0 83.0 14.0 9.0 9.0 11.0 9.0 36.0 30.0 38.0 16.0 6.0 4.0 6.0 5.0 4.0 25.0 58.0 4.0 1.0 1.0

1. 0 2.0 26.0 40.0 27.0 8.0 3.0 7.0 9.0 11.0 13.0 1.0 1.0 1.0 5.0 5.0

. 0

.0 1.0

5. 0
5. 0 7.0

.0

1. 0 7.0 5.0

.0

.0

.0

.0

.0

.0 1.0

.0

.0

1. 0

.0

.0

.0

.0 1.0

.0

1. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 51.0 154.0 23.0

12. 0
14. 0 18.0 15.0 69.0 83.0 76.0 30.0
17. 0
22. 0 31.0 33.0 23.0 S

SSW SW WSW W

WNW NW NNW TOTAL

.0 110.0 297.0 236.0 25.0 3.0

.0 671.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 60.00 50.90 0

2208 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-65

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - JUL/AUG/SEP 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/ 7/ 1/ 0]

TO

[2002/ 9/30/23]

PASQUILL STABILITY:

F WIND SPEED (MPH)

WIND FROM

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

CALMS 3.50 7.50 12.50 18.50 24.00 80.00 N

NNE NE ENE

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

.0 15.0 14.0 10.0 3.0 3.0 5.0 2.0 1.0 2.0 6.0 4.0 4.0 4.0

.0 7.0 2.0 15.0 48.0 3.0

1. 0 1.0

.0

.0 2.0 8.0 15.0 3.0 1.0 3.0 2.0 2.0

.0 2.0 18.0

.0

.0

.0

.0 1.0 1.0 2.0

2. 0 1.0 1.0 1.0 1.0 1.0
2. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

1. 0

.0

.0 1.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0 TOTAL 32.0 80.0 13.0 4.0 4.0 5.0 3.0 4.0 10.0 23.0 8.0 6.0 8.0 4.0 10.0 4.0 S

SSW SW WSW

.0

.0

.0

.0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0 82.0 104.0 30.0 2.0

.0

.0 218.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 60.00 50.90 0

2208 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-66

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

JUL/AUG/SEP 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/ 7/ 1/ 0]

TO

[2002/ 9/30/23]

PASQUILL STABILITY:

G WIND SPEED (MPH)

WIND FROM

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

3.50 7.50 12.50 18.50 24.00 80.00 CALMS TOTAL N

NNE NE ENE

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

.0

.0

.0 1.0

.0

.0

.0

.0

.0

.0

.0 2.0 1.0

.0

.0

.0

.0 1.

. 0

.0

. 0

. 0

. 0

.0

.0

.0

.0 3.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 1.0

.0 1.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 S

SSW SW WSW

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 2.0 1.0

.0 3.0

.0

.0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0 4.0 4.0

.0

.0

. 0

.0 8.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 60.00 50.90 0

2!? 08 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-67

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

JUL/AUG/SEP 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/ 7/ 1/ 0]

TO

[2002/ 9/30/23)

PASQUILL STABILITY:

ALL WIND SPEED (MPH)

WIND FROM

.60 -

CALMS 3.50 N

NNE NE ENE

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

.0 29.0 30.0 29.0 12.0 12.0 14.0 11.0 18.0 30.0 19.0 17.0

14. 0 15.0 10.0 19.0 9.0 3.50 -

7.50 75.0 179.0 46.0 32.0 24.0 21.0 16.0 135.0 115.0 76.0 34.0 12.0 10.0 18.0 11.0 17.0 7.50 -

12.50 153.0 160.0 27.0 7.0 7.0 4.0 8.0 110.0 79.0 48.0 16.0

14. 0 30.0 34.0 23.0 47.0 12.50 -

18.50 113.0 16.0 1.0

.0

1. 0

.0

.0 13.0

17. 0 22.0 3.0 3.0 5.0 19.0 37.0 34.0 18.50 -

24.00 13.0

.0

.0

.0

.0 1.0

.0

.0 1.0

. 0

.0 1.0

.0 3.0 5.0 6.0 24.00 -

80.00 1.0 1.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0 6.0 61.0

11. 0 TOTAL 384 0

384. 0 385.0 103.0 51.0 44.0 40.0 35.0 276.0 242.0 165.0 70.0 44.0 60.0 84.0 101.0 124.0 S

SSW SW WSW

.0

.0

.0

.0 W

WNW NW NNW

.0

.0

. 0

.0 TOTAL

.0 288.0 821.0 767.0 284.0 30.0 18.0 2208.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 60.00

50. 90 0

2208 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-68

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS - JUL/AUG/SEP 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/ 7/ I/ 0]

TO

[2002/ 9/30/23]

PASQUILL STABILITY:

A WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 24.00 -

80.00 N

NNE NE ENE

.0

. 0

.0

. 0 E

ESE SE SSE

.0

.0

.0

.0

.0

.0

. 0

. 0

. 0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 1.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

. 0

. 0

.0 5.0 5.0 1.0

.0

.0

.0

.0

1. 0

.0

.0

.0 1.0

.0

.0

.0 1.0

.0 1.0

.0

.0

. 0

.0

.0 1.0

.0

.0

1. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

1. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0 TOTAL 1.0

.0

.0

.0

.0

.0 7.0

.0 S

SSW SW WSW

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 W

WNW NW NNW

.0

.0

.0

.0

.0

.0

.0

.0 1.0

.0 1.0

1. 0 TOTAL

.0

.0 1.0 6.0 3.0 1.0

.0 11.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 122.00 112.00 0

2208 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-69

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

JUL/AUG/SEP 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/ 7/ 1/ 0]

TO

[2002/ 9/30/23]

PASQUILL STABILITY:

B WIND SPEED (MPH)

WIND FROM

.60 -

3.50 3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

7.50 12.50 18.50 24.00 80.00 CALMS TOTAL N

NNE NE ENE

.0

.0

.0

.0 E

ESE SE SSE

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 1.0 16.0 16.0 1.0

.0 1.0

.0

.0 1.0

.0

.0

.0 1.0

.0

.0

.0 1.0 3.0 19.0 1.0

.0 1.0

1. 0 4.0 5.0 4.0 4.0 6.0 1.

. 0

.0

. 0

. 0 3.0 3.0

.0 1.0 1.0

1. 0
1. 0 3.0 4.0 8.0 21.0

. 0

.0

.0

.0

.0

.0

.0

.0

1. 0 7.0

.0

.0

.0

.0

1. 0
7. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 2.0 1.0

1. 0 2.0

.0

.0

.0 1.0 4.0 38.0 2.0 1.0

.0 2.0 5.0 9.0 10.0

14. 0 35.0 S

SSW SW WSW

.0

.0

.0

.0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0

.0 19.0 49.0 42.0 9.0 4.0 123.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 122.00 112.00 0

2208 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-70

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS -

JUL/AUG/SEP 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M)

FOR PERIOD [Year/Month/Day/Hour)

[2002/ 7/ 1/ 0]

TO

[2002/ 9/30/23]

PASQUILL STABILITY:

C WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 N

NNE NE ENE

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

.0

.0

.0 1.

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 1.0

.0 1.0

.0 2.0

.0

32. 0
13. 0 2.0 1.0 1.0 1.0 2.0

.0 2.0 4.0 3. 0 3.0

.0

.0

.0 1.0 1.0 9.0 4.0 1.0

1. 0 2.0 2.0 6.0 1.0 5.0 30.0 1.

.0

.0 4.0 3.0 1.0 4.0 3.0 3.0 2.0 12.0

6. 0
4. 0
5. 0
2. 0
28. 0
1. 0

.0

.0

.0

.0

.0 1.0

.0 3.0

. 0

1. 0 1.0

.0 1.0 2.0 10.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 2.0 2.0 1.0 TOTAL 6.0

.0 2.0

.0 3.0 1.0 46.0 20.0 8.0 2.0 5.0 10.0 12.0 9.0 13.0 73. 0 S

SSW SW WSW

. 0

. 0

.0

.0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0 1.0 62.0 65.0 57.0 20.0 5.0 210.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 122.00 112.00 0

2208 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-71

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS JUL/AUG/SEP 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M)

FOR PERIOD [Year/Month/Day/Hour)

[2002/ 7/ 1/ 0)

TO

[2002/ 9/30/23]

PASQUILL STABILITY:

D WIND SPEED (MPH)

WIND FROM

.60 -

3.50 3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

7.50 12.50 18.50 24.00 80.00 CALMS TOTAL N

NNE NE ENE

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

. 0 4.0 4.0 4.0 6.0

.0 5.0 8.0 20.0 8.0 6.0 2.0 2.0

.0

.0 3.0 4.0 38.0 21.0 16.0 19.0 9.0 8.0 41.0 35.0 19.0 12.0 1.0 4.0 2.0 6.0 7.0 34.0

54. 0 28.0 16.0
12. 0 5.0 5.0 46.0 52.0 21.0 11.0 8.0 13.0 6.0 11.0 19.0 74.0 38.0 3.0 2.0

.0

.0

.0 30.0 32.0 18.0 4.0 4.0 8.0 10.0 29.0 24.0 84.0

.0

.0

.0

.0

.0 3.0

3. 0 1.0
6. 0

.0

.0 2.0 2.0 9.0 6.0 21.0 1.0

.0

.0 1.0

1. 0 2.0 9.0
1. 0 6.0 3.0

.0

.0

2. 0
9. 0
6. 0
3. 0 134.0 56.0 38.0 37.0 15.0 18.0 128.0 141.0 72.0 33.0 15.0 27.0 22.0
64. 0 65.0 220.0 S

SSW SW WSW

. 0

.0

.0

.0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0 76.0 272.0 381.0 286.0 48.0 22.0 1085.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 122.00 112.00 0

2208 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-72

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS JUL/AUG/SEP 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/ 7/ 1/ 0]

TO

[2002/ 9/30/23]

PASQUILL STABILITY:

E WIND SPEED (MPH)

WIND FROM

.60 -

CALMS 3.50 3.50 -

7.50 -

12.50 -

18.50 -

7.50 12.50 18.50 24.00 24.00 -

80.00 TOTAL N

NNE NE ENE E

ESE SE SSE

.0

.0

.0

. 0

. 0

. 0

. 0

. 0

.0

.0

. 0

. 0

. 0

. 0

. 0

. 0 7.0 6.0 6.0 5.0 3.0 8.0 8.0 13.0 23.0 27.0 8.0 3.0 2.0 2.0 7.0 2.0 10.0 4.0 5.0 3.0 5.0 3.0 17.0 48.0 44.0 16.0 6.0 3.0 2.0 6.0

14. 0 17.0 5.0 1.0 1.0 4.0 3.0 6.0 26.0 57.0 30.0 9.0 5.0 6.0 6.0 7.0 21.0 47.0 4.0 3.0

.0

.0

.0 1.0 6.0 8.0 1.0 1.0

.0 7.0 9.0 9.0 4.0 17.0

.0

.0

.0

.0

.0

.0

.0

.0 2.0

.0

.0

.0 2.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0 1.0

.0

.0 26.0

14. 0 12.0 12.0 11.0 18.0 57.0 126.0 100. 0 53.0 19.0 19.0 21.0 25.0 46.0 83.0 S

SSW SW WSW W

WNW NW NNW TOTAL

.0 130.0 203.0 234.0 70.0 4.0 1.0 642.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 122.00 112.00 0

2208 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-73

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

JUL/AUG/SEP 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/ 7/ 1/ 0]

TO 12002/ 9/30/23]

PASQUILL STABILITY:

F WIND SPEED (MPH)

WIND FROM N

NNE NE ENE

.60 CALMS 3.50 3.50 -

7.50 7.50 -

12.50 -

18.50 -

12.50 18.50 24.00 E

ESE SE SSE

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 1.0 5.0

.0

1. 0 3.0 2.0 8.0 3.0 7.0 8.0 4.0

.0 3.0 2.0 3.0

.0 6.0 3.0

.0

.0 3.0 3.0 3.0 3.0 2.0 7.0 4.0 2.0 31.0 4.0

10. 0 14.0

.0

.0

.0

.0

.0

.0

.0 1.0

.0

. 0 1.0 3.0

.0

.0

.0 15.0 1.0

. 0

.0

.0

.0

.0

.0

. 0

.0

.0

.0 2.0 2.0

.0

.0 2.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0 24.00 -

80.00

_ ___.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0 TOTAL 8.0----

8.0 8.0 1.0 1.0 3.0 2.0 11.0 7.0 9.0 15.0 5.0 7.0 8.0 6.0 13.0 31.0 S

SSW SW WSW W

WNW NW NNW TOTAL

.0 50.0 57.0 20.0 7.0

.0

.0 134.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 122.00 112.00 0

2208 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-74

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS - JUL/AUG/SEP 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/ 7/ 1/ 0)

TO

[2002/ 9/30/23)

PASQUILL STABILITY:

G WIND SPEED (MPH)

WIND FROM

.60 -

3.50 -

CALMS 3.50 7.50 N

NNE NE ENE

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

.0

. 0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 7.50 -

12.50 1.0 1.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

1. 0
1. 0

.0

.0

.0 12.50 -

18.50 18.50 -

24.00

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 1.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

. 0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0 24.00 -

80.00 TOTAL S

SSW SW WSW

.0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0 1.0 2.0

.0

.0

.0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0

.0

.0 2.0 1.0

.0

.0 3.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 122.00 112.00 0

2208 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-75

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - JUL/AUG/SEP 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/ 7/ 1/ 0)

TO

[2002/ 9/30/23]

PASQUILL STABILITY:

ALL WIND SPEED (MPH)

WIND FROM

.60 3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

3.50 7.50 12.50 18.50 24.00 80.00 CALMS TOTAL N

NNE NE ENE

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

.0

12. 0 15.0 11.0 12.0 6.0 15.0 24.0 36.0 38.0 41.0
14. 0 5.0 5.0 4.0 13.0 6.0 55.0 28.0 22.0 22.0 16.0 12.0 110.0 100.0 67.0 36.0 8.0
10. 0 10.0 16.0 33.0 69.0 63.0 29.0
17. 0 16.0
10. 0 15.0 105.0 115.0 51.0 21.0 17.0 29.0 25.0 23.0 49.0 172.0 46.0 6.0 2.0

.0

.0 1.0 44.0 43.0 22.0 5.0 6.0 24.0 29.0 47.0 38.0 153.0 1.0

.0

. 0

. 0

.0

.0 4.0 1.0 12.0

.0 1.0 1.0 4.0 10.0 10.0 38.0 1.0

. 0 1.0 2.0 14.0 9.0 5.0

1. 0

.0

.0

.0

.0 2.0 14.0 9.0 5.0 177.0 78.0 52.0 50.0 33.0 43.0 287.0 296.0 190.0 103.0 46.0 69.0 75.0 114.0 152.0 443.0 S

SSW SW WSW

. 0

.0

. 0

. 0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0 257.0 614.0 757.0 466.0 82.0 32.0 2208.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 122.00 112.00 0

2208 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-76

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

OCT/NOV/DEC 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/10/ 1/ 0)

TO

[2002/12/31/23]

PASQUILL STABILITY:

A WIND SPEED (MPH)

WIND FROM

.60 -

3.50 3.50 -

7.50 7.50 -

12.50 -

18.50 -

24.00 -

12.50 18.50 24.00 80.00 CALMS TOTAL N

NNE NE ENE

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

1. 0

.0

.0

.0

.0

.0

1. 0

.0 10 0

.0

.0 1.0 1.0

.0 3.0 7.0 1.0

.0

.0 2.0 0 3.0 10.0 5.0 10.

.0

.0

.0 6.0 2.0

.0

.0

6. 0

.0

.0

.0

.0

.0

6. 0
2. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 20.0

.0

.0

.0 1.0

.0

.0 3.0 14.0

1. 0

. 0

. 0 2.0 3.0

17. 0 7.0 S

SSW SW WSW

. 0

.0

.0

.0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0 2.0 42.0 24.0

.0

.0

.0 68.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 10.00 50.90 9

2199 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-77

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS - OCT/NOV/DEC 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/10/ 1/ 0]

TO

[2002/12/31/23]

PASQUILL STABILITY:

B WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 N

NNE NE ENE

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

.0

.0

. 0

.0

. 0

. 0

.0

.0

.0

.0

.0

.0

.0

.0 1.0 1.0 1.0 13.0 1.0

.0 1.0

.0

.0

.0 3.0 8.0 3.0

.0

.0 3.0 3.0 4.0 2.0 10.0

.0

.0

.0

.0

.0 3.0

.0 3.0

.0 5.0 1.0

.0

.0 5.0

1. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 TOTAL 23.0 1.0

.0 1.0

.0

.0

.0 3.0 11.0 3.0

.0

.0 3.0 4.0 10.0 4.0 S

SSW SW WSW

.0

.0

. 0

.0 W

WNW NW NNW

.0

.0

.0

. 0 TOTAL

.0 3.0 41.0 19.0

.0

.0

.0 63.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 10.00 50.90 9

2199 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-78

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS OCT/NOV/DEC 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD [Year/Month/Day/Hourl

[2002/10/ 1/ 0]

TO

[2002/12/31/23]

PASQUILL STABILITY:

C WIND SPEED (MPH)

WIND FROM

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

CALMS 3.50 7.50 12.50 18.50 24.00 24.00 -

80.00 N

NNE NE ENE

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0 1.0 3.0

. 0

.0

.0 1.0 1.0

.0

.0 16.0 5.0

.0

.0 2.0

.0 3.0 2.0 11.0

3. 0
2. 0 2.0 8.0 4.0 10.0 3.0 5.0 1.0

.0

.0

.0

.0

.0

.0

1. 0

.0 1.0 3.0

1. 0
3. 0 8.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 1.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 TOTAL 21.0 6.0

.0

.0

.0

. 0

.0 3.0 15.0 3.0 2.0 2.0 10.0 8.0 19.0 3.0 S

SSW SW WSW

.0

.0

.0

.0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0 6.0 66.0

19. 0 1.0

.0

.0 92.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 10.00 50.90 9

2199 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-79

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - OCT/NOV/DEC 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/10/ 1/ 0]

TO

[2002/12/31/23)

PASQUILL STABILITY:

D WIND SPEED (MPH)

WIND FROM

.60 -

CALMS 3.50 N

NNE NE ENE

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

.0 17.0 28.0 17.0 8.0 4.0 4.0 7.0 14.0 26.0 20.0 15.0 10.0 11.0 6.0

12. 0 4.0 3.50 -

7.50 116.0 181.0 11.0 1.0

.0 2.0 2.0

22. 0 47.0 21.0 11.0 20.0 35.0 47.0 59.0 57.0 7.50 -

12.50 57.0 90.0

.0

.0

.0

.0 2.0 20.0 20.0 4.0 4.0

4. 0 1.0 18.0 29.0 7.0 12.50 -

18.50

.0

1. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

2. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

. 0

.0

.0

.0

.0

.0

.0 18.50 -

24.00 24.00 -

80.00 TOTAL 190.0 300.0 28.0 9.0 4.0 4.0 9.0 38.0 93.0 45.0 26.0 34.0 47.0 71.0 102.0 68.0 S

SSW SW WSW

.0

.0

.0

. 0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0 203.0 630.0 232.0 3.0

.0

.0 1068.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 10.00 50.90 9

2199 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-80

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

OCT/NOV/DEC 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD [Year/Month/Day/Hour)

[2002/10/ 1/ 0)

TO

[2002/12/31/23]

PASQUILL STABILITY:

E WIND SPEED (MPH)

WIND FROM N

NNE NE ENE

.60 -

CALMS 3.50

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

.0 18.0 58.0 51.0 23.0 12.0 18.0 15.0 38.0 47.0 31.0 25.0 21.0 22.0 13.0

14. 0 9.0 3.50 -

7.50 21.0

75. 0 24.0 2.0

.0

.0

.0 11.0

60. 0 24.0 8.0 5.0 9.0 26.0
14. 0 6.0 1.0 4.0

.0

.0

.0

. 0

.0

.0 11.0

.0

.0

.0

.0 2.0 3.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 7.50 -

12.50 12.50 -

18.50

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0 18.50 -

24.00 24.00 -

80.00 TOTAL 40.0 137.0 75.0 25.0 12.0 18.0 15.0 49.0 118.0 55.0 33.0 26.0 31.0 41.0 31.0 15.0 S

SSW SW WSW

.0

.0

.0

.0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0 415.0 285.0 21.0

. 0

.0

.0 721.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS.

DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 10.00 50.90 9

2199 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-81

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - OCT/NOV/DEC 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD [Year/Month/Day/Hour)

[2002/10/ 1/ 0]

TO

[2002/12/31/23]

PASQUILL STABILITY:

F WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

FROM CALMS 3.50 7.50 12.50 18.50 18.50 -

24.00 24.00 -

80.00 N

NNE NE ENE

.0

. 0

. 0

.0 E

ESE SE SSE

.0

.0

.0

.0 22.0 37.0 21.0 9.0 7.0 2.0 4.0 8.0 13.0 3.0

1. 0 3.0 4.0 2.0 2.0 3.0

.0 10.0 16.0 2.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

1. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 TOTAL 22.0 47.0 38.0 11.0 7.0 2.0 4.0 8.0 13.0 3.0 1.0 3.0 4.0 2.0 2.0 3.0 S

SSW SW WSW

.0

.0

.0

.0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0 141.0 28.0 1.0

.0

.0

.0 170.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 10.00 50.90 9

2199 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-82

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

OCT/NOV/DEC 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD [Year/Month/Day/Hour)

[2002/10/ 1/ 0)

TO

[2002/12/31/23]

PASQUILL STABILITY:

G WIND SPEED (MPH)

WIND FROM

.60 -

3.50 3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

7.50 12.50 18.50 24.00 80.00 CALMS TOTAL N

NNE NE ENE

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

.0 4.0 9.0 1.0 1.0 1.0

. 0 1.0

.0

.0

.0

.0 1.0

.0

.0 1.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

. 0

.0

. 0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 4.0 9.0 1.0 1.0

.0

.0 1.0

.0 S

SSW SW WSW

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 W

WNW NW NNW

.0

.0

.0

.0

. 0

.0

. 0

.0

.0

.0 1.0

.0 TOTAL

.0 17.0

.0

.0

.0

.0

.0 17.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 10.00 50.90 9

2199 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-83

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

OCT/NOV/DEC 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/10/ 1/ 0J TO

[2002/12/31/23]

PASQUILL STABILITY:

ALL WIND SPEED (MPH)

WIND FROM

.60 -

3.50 3.50 -

7.50 7.50 -

12.50 -

18.50 -

12.50 18.50 24.00 24.00 -

80.00 CALMS TOTAL N

NNE NE ENE

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

.0 61.0 132. 0 90.0 41.0 23.0 24.0 27.0 61.0 90.0

54. 0 41.0 34.0 38.0 23.0 31.0 17.0 176.0 272.0 51.0 6.0 1.0

.0 2.0 41.0 133.0

52. 0 21.0 27.0 57.0 83.0 97.0 73.0 83.0 95.0 1.0

.0 2.0

.0 4.0 2.0

41. 0 4.0 2.0
4. 0 23.0
23. 0 51.0 10.0

.0

1. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

3. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

. 0

.0

.0

.0

.0

.0

.0

.0 320.0 500.0 142.0 47.0 24.0 24.0 29.0 104.0 264.0 110. 0 62.0 65.0 97.0 129.0 182.0 100. 0 S

SSW SW WSW

.0

.0

.0

.0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0 787.0 1092.0 316.0 4.0

.0

.0 2199.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 10.00 50.90 9

2199 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-84

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

OCT/NOV/DEC 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/10/ 1/ 0]

TO

[2002/12/31/23]

PASQUILL STABILITY:

A WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 N

NNE NE ENE

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 1.0 1.0 2.0 2.0 3.0

.0

.0

.0

.0

.0 1.0

.0 S

SSW SW WSW

.0

.0

.0

.0 4.0

.0

. 0

.0

.0

.0

.0 4.0 4.0 1.0

.0 3.0 3.0 4.0 23.0 9.0

.0

.0

.0

.0

.0

.0

.0

.0 4.0 2.0 8.0 1.0 2.0 8.0

27. 0 1.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

8. 0

.0

9. 0 24.00 -

80.00 1.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

1. 0

.0 2.0 TOTAL 15.0

.0

.0

.0

.0 1.0

.0 6.0 7.0 5.0

.0

.0 1.0 5.0 21.0 7.0 68.0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0

.0 7.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 60.00 50.90 68 2140 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-85

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

OCT/NOV/DEC 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/10/ 1/ 0]

TO

[2002/12/31/23]

PASQUILL STABILITY:

B WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 N

NNE NE ENE

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

.0

.0

. 0

. 0

. 0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0 4.0 3.0 1.0

.0

.0

.0

4. 0
3. 0
1. 0

.0

.0

.0

.0

2. 0

.0 S

SSW SW WSW

.0

.0

.0

.0 9.0

.0 1.0 1.0

.0 2.0 1.0 2.0 1.0

.0 1.0 3.0 3.0 5.0

3. 0
3. 0
25. 0 6.0

.0

.0 1.0 2.0

.0

.0 1.0 1.0 2.0 5.0 3.0 19.0

1. 0
5. 0
19. 0
2. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

1. 0
1. 0

.0 4.0 24.00 -

80.00 1.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 2.0

.0 3.0 TOTAL 18.0

.0

.0 1.0

.0

.0

.0 6.0 5.0 3.0 1.0

.0 1.0 7.0 13.0 6.0 61.0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

. 0

.0 10.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 60.00 50.90 68 2140 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-86

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

OCT/NOV/DEC 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M)

FOR PERIOD [Year/Month/Day/Hourl

[2002/10/ 1/ 0)

TO

[2002/12/31/23]

PASQUILL STABILITY:

C WIND SPEED (MPH)

WIND FROM

.60 CALMS 3.50 N

NNE NE ENE

. 0

. 0

. 0

. 0 E

ESE SE SSE

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

. 0 3.50 -

7.50 3.0

.0

.0

.0

.0

.0 4.0 4.0 1.0 1.0

.0O

.0 1.0 3.0 2.0 7.50 -

12.50

11. 0 1.0

.0

.0

.0 2.0 3.0 2.0 3.0 2.0 5.0

1. 0
5. 0 3.0 6.0 1.0 35.0 12.50 -

18.50

7. 0

.0

.0 1.0 3.0

.0

.0 12.0

.0

.0

.0

1. 0
5. 0

.0

20. 0 18.50 -

24.00

.0. 0

. 0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0 4.0 4.0 4.0 8.0

8. 0 24.00 -

80.00

.0

.0

.0

.0

.0

. 0

. 0

.0

.0

.0

.0

.0

.0

.0 4.0

.0 4.0 TOTAL 21.0---

21.0 1.0

.0

.0

.0

.0 7.0

7. 0 11.0 3.0

.0 2.0 8.0 13.0 20.0 3.0 89.0 S

SSW SW WSW

. 0

. 0

. 0

. 0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0

.0 22.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 60.00 50.90 68 2140 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-87

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

OCT/NOV/DEC 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/10/ 1/ 0]

TO

[2002/12/31/23)

PASQUILL STABILITY:

D WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 N

NNE NE ENE

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

.0 1.0 7.0 5.0 5.0 1.0

.0 5.0 7.0 10.0 3.0 1.0 4.0 3.0

. 0 3.0

.0 23.0 44.0 23.0 10.0 6.0 3.0 6.0 11.0 29.0 13.0 8.0 8.0 9.0 8.0 8.0 8.0 83.0

94. 0 10.0 1.0

.0

.0 13.0

12. 0 27.0 13.0 11.0 12.0 19.0 26.0 25.0 22.0 95.0 15.0 5.0

.0

.0 1.0

.0 7.0

11. 0 13. 0 13.0
12. 0 13.0 29.0 52.0 49.0 24.0 2.0

.0

.0

.0

.0

.0

.0 2.0

.0

.0 2.0 1.0 14.0 33.0 7.0 24.00 -

80.00 2.0

. 0

.0O

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 3.0 6.0

.0 TOTAL 228.0 162.0 43.0 16.0 7.0 3.0

24. 0 37.0 79.0 42.0 21.0 38.0 45.0 80.0 127.0 86.0 S

SSW SW WSW

.0

.0

.0

.0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0 55.0 217.0 368.0 302.0 85.0 11.0 1038.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 60.00 50.90 68 2140 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-88

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - OCT/NOV/DEC 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 {M)

FOR PERIOD [Year/Month/Day/Hour)

[2002/10/ 1/ 0)

TO

[2002/12/31/23]

PASQUILL STABILITY:

E WIND SPEED (MPH)

WIND FROM

.60 -

CALMS 3.50 3.50 -

7.50 -

12.50 -

18.50 -

7.50 12.50 18.50 24.00 N

NNE NE ENE E

ESE SE SSE

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 6.0 12.0 11.0 2.0 5.0 3.0 3.0 6.0 7.0 5.0 10.0 10.0 3.0 4.0

1. 0 3.0 32.0 75.0
14. 0 4.0 3.0 11.0 13.0 26.0 29.0 24.0 16.0 11.0 14.0 11.0 10.0 5.0 22.0 32.0 2.0

.0 2.0

2. 0 6.0
14. 0 31.0 44.0 18.0 10.0 10.0 27.0 15.0 8.0 2.0 3.0

.0 1.0

.0 7.0 4.0 1.0

10. 0 71.0 4.0 9.0

.0

19. 0
8. 0 9.0

.0

.0

.0

.0

.0

.0

.0

.0 4.0

.0

.0

.0

.0 2.0 5.0

.0 24.00 -

80.00

_ ___.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 1.0 1.0

.0

. 0 TOTAL 62.0 122.0 27.0 6.0 8.0 16.0 22.0 47.0 81.0 80.0 48.0 31.0 27.0 64.0 39.0 25.0 S

SSW SW WSW W

WNW NW NNW TOTAL

.0 91.0 298.0 241.0 63. 0 11.0 1.0 705.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 60.00 50.90 68 2140 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-89

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - OCT/NOV/DEC 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M)

FOR PERIOD [Year/Month/Day/Hour)

[2002/10/ 1/ 0]

TO

[2002/12/31/23]

PASQUILL STABILITY:

F WIND SPEED (MPH)

WIND FROM

.60 -

CALMS 3.50 N

NNE NE ENE

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

.0 7.0 9.0 2.0 2.0 3.0 3.0 3.0 4.0 7.0 2.0 3.0 7.0 3.0 4.0 3.0 5.0 3.50 -

7.50 16.0

24. 0

.0 1.0

.0 9.0 7.0 1.0 10.0 9.0 7.0 5.0 2.0

.0 1.0 2.0 7.50 -

12.50 3.0 4.0

.0O

.0O

.0 4.0 2.0 1.0 6.0 2.0 1.0

.0 1.0 2.0

.0

.0 12.50 -

18.50

.0

1. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

. 0 18.50 -

24.00 24.00 -

80.00 TOTAL 26.0 38.0 2.0 2.0 3.0 3.0 3.0 5.0 23.0 13.0 11.0 12.0 6.0 4.0 4.0 7.0 S

SSW SW WSW

.0

.0

.0

.0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0 67.0 77.0 17.0 1.0

.0

.0 162.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 60.00 50.90 68 2140 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-90

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

OCT/NOV/DEC 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M)

FOR PERIOD [Year/Month/Day/Hour)

[2002/10/ I/ 0)

TO

[2002/12/31/23]

PASQUILL STABILITY:

G WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 24.00 -

80.00 N

NNE NE ENE

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

.0 1.0 2.0 2.0

.0 1.0

.0

.0 1.0 1.0 2.0 2.0 1.0

.0

.0

.0

.0

.0

3. 0

.0

.0

.0

.0

.0 1.0

.0

.0

.0

.0

.0

.0

.0

1. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0 TOTAL 1.0 5.0 2.0

.0 1.0

.0

.0 1.0 1.0 2.0 2.0 1.0 S

SSW SW WSW

.0

.0

.0

.0 W

WNW NW NNW

. 0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0 1.0 TOTAL

.0 13.0 4.0

.0

.0

.0

.0 17.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 60.00 50.90 68 2140 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-91

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

OCT/NOV/DEC 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/10/ 1/ 0]

TO

[2002/12/31/23]

PASQUILL STABILITY: ALL WIND SPEED (MPH)

WIND FROM

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

3.50 7.50 12.50 18.50 24.00 80.00 CALMS TOTAL N

NNE NE ENE

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

.0 15.0 30.0 20.0 9.0 10.0 6.0

11. 0 18.0 25.0 12. 0 16.0 22.0 9.0 8.0 7.0 8.0 74.0 146.0 37.0
14. 0 9.0 15.0 19.0 48.0 82.0 48.0 31.0 24.0 25.0 20.0 25.0 18.0 132.0 131.0 12.0 2.0 2.0 2.0 19.0 34.0 72.0 62.0 31.0 23.0 35.0 64.0 52.0 38.0 119. 0 19.0 5.0

.0

.0 9.0

.0

9. 0 22.0 26.0 5.0 13. 0 18.0 56.0 76.0 64.0 27.0 2.0

.0 6.0

.0

.0 2.0 1.0

6. 0

.0

.0 2.0 1.0

21. 0 51.0 7.0 4.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 4.0

13. 0

.0 371.0 328.0 74.0 25.0 19.0 23.0 49.0 109. 0 207.0 148.0 83.0 84.0 88.0 173.0 224.0 135.0 S

SSW SW WSW

.0

.0

.0

.0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0 226.0 635.0 709.0 432.0 117.0 21.0 2140.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 60.00 50.90 68 2140 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-92

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS OCT/NOV/DEC 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/10/ 1/ 0]

TO

[2002/12/31/23]

PASQUILL STABILITY:

A WIND SPEED (MPH)

WIND FROM N

NNE NE ENE E

ESE SE SSE CALMS

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 S

SSW SW WSW

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

. 0

. 0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

3.50 7.50 12.50 18.50 24.00 80.00

.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0 2.0

.0

. 0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0 TOTAL

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0 W

WNW NW NNW TOTAL

.0

.0

.0

.0

.0

.0 1.0

.0

.0

.0 3.0

.0

.0

.0 2.0 1.0 3.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS) 122.00 112.00 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 9 2199 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-93

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

OCT/NOV/DEC 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/10/ 1/ 0]

TO

[2002/12/31/23]

PASQUILL STABILITY:

B WIND SPEED (MPH)

WIND FROM

.60 -

3.50 3.50 -

7.50 7.50 -

12.50 -

18.50 -

12.50 18.50 24.00 24.00 -

80.00 CALMS TOTAL N

NNE NE ENE E

ESE SE SSE

.0

.0

.0

.0

.0

. 0

. 0

.0

.0

. 0

.0

. 0

.0

.0

.0

.0

.0

.0

. 0

.0

. 0

.0

.0

.0

.0

.0

. 0

. 0

.0

.0

.0

.0

.0

.0

.0

. 0

. 0

. 0

.0

.0

.0

.0

.0

.0

. 0 3.0

.0

.0

.0 1.0

1. 0 3.0

. 0

. 0

. 0

. 0

1. 0
1. 0

. 0

. 0

.0

.0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

. 0

.0

. 0

.0 3.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 1.0 3.0 S

SSW SW WSW

.0

.0

.0

.0

.0

.0

.0

.0 W

WNW NW NNW

. 0

. 0

. 0

. 0

.0 2.0

.0

.0 1.0 6.0

.0

.0 TOTAL

.0

.0

.0 6.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS.

DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER.

DURING THIS PERIOD (ALL STABILITIES) 0 3.0 122.00 112.00 9

2199 2.0 11.0 NOTE:

CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-94

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

OCT/NOV/DEC 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/10/ 1/ 0]

TO

[2002/12/31/231 PASQUILL STABILITY:

C WIND SPEED (MPH)

WIND FROM

.60 -

3.50 3.50 -

7.50 7.50 -

12.50 -

18.50 -

12.50 18.50 24.00 24.00 -

80.00 CALMS TOTAL N

NNE NE ENE

.0

.0

.0

.0 E

ESE SE SSE

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

1. 0

.0

.0

.0

.0

.0

.0

1. 0

.0

.0 S

SSW SW WSW

.0

.0

.0

.0

.0

.0

.0

.0 1.0

.0 1.0 1.0 1.0

.0

.0

.0 3.0 1.0 5.0 3.0 16.0

.0

.0

.0

.0

.0

.0

.0

.0 2.0

.0

.0 1.0 2.0 6.0 1.0 8.0 20.0

. 0

. 0

.0

.0

.0

.0

.0

.0 4.0

.0

.0

. 0

.0 2.0 1.0 2.0 9.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0 3.0

.0

.0 3.0

.0

.0

.0

.0 1.0

.0 2.0 1.0 7.0

. 0

.0 1.0 5.0 13.0 7.0 13.0 50.0

.0

.0

.0

.0 W

WNW NW NNW TOTAL

.0

.0

.0

.0

.0

.0 2.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 122.00 112.00 9

2199 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-95

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

OCT/NOV/DEC 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/10/ 1/ 0]

TO

[2002/12/31/23]

PASQUILL STABILITY:

D WIND SPEED (MPH)

WIND FROM

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

3.50 7.50 12.50 18.50 24.00 80.00 CALMS TOTAL N

NNE NE ENE

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

.0 4.0 2.0 3.0 2.0 3.0 4.0 4.0 8.0 4.0 2.0

.0 4.0 1.0

.0 1.0 1.0 29.0

14. 0 9.0
14. 0 2.0 7.0 22.0 27.0 14.0 4.0 11.0 9.0 10.0 13. 0 10.0 20.0 72.0 20.0 4.0 5.0 4.0 12.0 17.0
24. 0
24. 0 13.0 24.0 19.0 47.0 36.0 18.0 68.0 59.0 13.0

.0

.0 1.0 5.0 2.0 20.0 26.0 7.0

14. 0 23.0 62.0 70.0 56.0 132.0
10. 0

. 0

.0 1.0 3.0 8.0 1.0 3.0

8. 0 5.0 52.0 5.0
26. 0
51. 0
13. 0 45.0 2.0

.0

.0

.0

.0

.0

.0 3.0

.0

. 0

. 0 3.0 17.0 23.0 5.0 13.0 176.0 49.0 16.0 21.0 10.0 28.0 46.0 85.0 76.0 26.0 54.0 63.0 163.0 193.0 103.0 279.0 S

SSW SW WSW

.0

.0

.0

.0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0 43.0 215.0 407.0 490.0 167.0 66.0 1388.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 122.00 112.00 9

2199 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-96

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS -

OCT/NOV/DEC 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M)

FOR PERIOD [Year/Month/Day/Hour]

[2002/10/ 1/ 0]

TO

[2002/12/31/23]

PASQUILL STABILITY:

E WIND SPEED (MPH)

WIND FROM CALMS

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

3.50 7.50 12.50 18.50 24.00 80.00 N

NNE NE ENE

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

.0 8.0 14. 0 5.0 5.0 1.0 7.0 5.0 3.0

13. 0
10. 0 6.0 7.0 2.0 4.0 2.0 5.0 17.0 9.0 6.0 5.0 1.0
10. 0 24.0 32.0 21.0 22.0 8.0 5.0 8.0
1. 0 8.0 28.0 23.0 3.0 4.0 1.0 3.0 15.0 21.0 43.0 37.0
19. 0 10.0 15.0 15.0 10.0 11.0 41.0 1.0

.0

.0

.0

.0

.0

11. 0
13. 0 18.0 4.0 6.0

.0 6.0

1. 0 3.0 10.0

.0

.0

.0

.0

.0

.0 3.0

.0 2.0

.0

.0

.0 4.0 1.0 1.0 1.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

. 0

.0 1.0

.0

.0 TOTAL 49.0 26.0 15.0 11.0 5.0

32. 0 64.0 91.0 91.0 55.0 30.0 27.0 35.0 18.0 25.0 85.0 S

SSW SW WSW

.0

.0

.0

.0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0 97.0 205.0 271.0 73.0

12. 0 1.0 659.0 DATA MEASUREMENT HEIGHT {M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 122.00 112.00 9

2199 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-97

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

OCT/NOV/DEC 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M)

FOR PERIOD [Year/Month/Day/Hour)

[2002/10/ 1/ 0]

TO

[2002/12/31/23]

PASQUILL STABILITY:

F WIND SPEED (MPH)

WIND FROM

.60 -

3.50 3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

7.50 12.50 18.50 24.00 80.00

CALMS, TOTAL N

NNE NE ENE

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

.0 2.0 1.0

.0

.0 1.0 2.0 3.0 4.0 5.0 3.0 3.0

. 0

1. 0 2.0 1.0

.0 6.0 6.0

.0

.0 1.0

1. 0 2.0 10.0 6.0 2.0 3.0 2.0 1.0 2.0 2.0 2.0 1.

.0

.0 2.0 1.0

.0 9.0

.0

.0

2. 0
1. 0

.0

.0

.0

.0

9. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

2. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 9.0 7.0

.0

. 0 1.0 3.0 5.0

14. 0 11.0 7.0 7.0 2.0 2.0 4.0 3.0 13.0 S

SSW SW WSW

.0

.0

.0

.0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0 28.0 45.0 13. 0 2.0

.0

.0 88.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 122.00 112.00 9

2199 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-98

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

OCT/NOV/DEC 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M)

FOR PERIOD [Year/Month/Day/Hour)

[2002/10/ 1/ 0J TO

[2002/12/31/23]

PASQUILL STABILITY:

G WIND SPEED (MPH)

WIND FROM

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

NNE NE ENE

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

.0 S

SSW SW WSW

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

. 0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

. 0

. 0

.0

.0

.0

.0

.0

.0

.0

. 0

. 0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0

.0

.0

. 0

.0

.0

.0

.0 W

WNW NW NNW

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0 TOTAL

.0

.0

.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 122.00 112.00 9

2199 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-99

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 INDIAN POINT (UNITS 2 & 3) -

JOINT FREQUENCY DISTRIBUTIONS -

OCT/NOV/DEC 2002 BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M)

FOR PERIOD (Year/Month/Day/Hourl

[2002/10/ 1/ 0]

TO

[2002/12/31/23]

PASQUILL STABILITY:

ALL WIND SPEED (MPH)

WIND FROM

.60 -

3.50 3.50 -

7.50 -

12.50 -

7.50 12.50 18.50 18.50 -

24.00 24.00 -

80.00 CALMS TOTAL N

NNE NE ENE

.0

.0

.0

.0 E

ESE SE SSE

.0

.0

.0

.0

14. 0 17.0 8.0 7.0 5.0
13. 0
12. 0 15.0 22.0 15.0 9.0 11.0 4.0 6.0 4.0 6.0 52.0 29.0 15.0 19.0 3.0 18.0 49.0 69.0 41.0 28.0 22.0 16.0
19. 0 17.0 20.0 50.0 96.0 23.0 8.0 6.0 8.0 27.0 40.0 71.0
62. 0 34.0 35.0 34.0 66.0 48.0 34.0 121.0 60.0 13.0

.0

.0

1. 0 5.0 13.0 33.0 46.0 11.0 20.0
24. 0 70.0 77.0 60.0 152. 0 10.0

.0

.0

.0

.0

.0 4.0 3.0

14. 0

.0 5.0 5.0 30.0 59.0 15.0 48.0 2.0

.0

.0

.0

.0

.0

.0 3.0

.0

.0

.0 3.0 17.0 30.0 5.0 13. 0 234.0 82.0 31.0 32.0

17. 0 63.0 118.0 194.0 185.0 88.0 91.0 93.0 206.0 237.0 138.0 390.0 S

SSW SW WSW

.0

.0

.0

.0 W

WNW NW NNW

.0

.0

.0

.0 TOTAL

.0 168.0 467.0 713.0 585.0 193.0 73.0 2199.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE)

TEMPERATURE SENSOR SEPARATION (METERS)

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 122.00 112.00 9

2199 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-100

NL-03-6 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 ANNUAL EFFLUENT AND WASTE DISPOSAL REPORT F -

REPORTABLE CHANGES TO THE PROCESS CONTROL PROGRAM (PCP)

OFFSITE DOSE CALCULATION MANUAL (ODCM)

AND RADIOACTIVE WASTE SYSTEMS G -

REPORTABLE ITEMS THE RADIOACTIVE LIQUID EFFLUENT MONITORING INSTRUMENTATION RADIOACTIVE GASEOUS EFFLUENT MONITORING INSTRUMENTATION H -

UNPLANNED RELEASES 2002 ENTERGY NUCLEAR OPERATIONS, INC.

INDIAN POINT UNIT NOS. 1 & 2 DOCKET NOS. 50-03 & 50-247 MAY 2003

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 SECTION F Reportable Changes A. Process Control Program (PCP)

Section 6.14.1 of the Indian Point Unit No. 2 Technical Specifications requires that the licensee initiated changes to the PCP be reported to the Commission in the Annual Radioactive Effluent Release Report.

During the 2002 reporting period there were no changes to the PCP.

B. Offsite Dose Calculation Manual (ODCM)

Section 6.15.2 of the Indian Point Unit No. 2 Technical Specifications requires that changes to the ODCM be reported to the Commission in the Annual Radioactive Effluent Release Report.

During the 2002 reporting period there were no changes to the ODCM.

C. Radioactive Waste Systems (RWS)

Section 6.16.1 of the Indian Point Unit No. 2 Technical Specifications requires that major changes to the RWS be reported to the Commission in the Annual Radioactive Effluent Release Report.

During the 2002 reporting period there were no major changes made to the RWS.

F-1

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 SECTION G Reportable Items A.

Radioactive Liquid Effluent Monitoring Instrumentation None B.

Radioactive Gaseous Effluent Monitoring Instrumentation None G-1

NL-03-068 May, 2003 Re: Indian Point Unit Nos. 1 & 2 Docket Nos. 50-03 & 50-247 SECTION H Unplanned Releases A. Unplanned Liquid Releases None B. Unplanned Gaseous Releases None C. Excessive Activity In Liquid Holdup Tanks On November 7, 2002 while draining the Reactor Coolant System (RCS) to the Refueling Water Storage Tank (RWST) approximately 42,200 gallons of water was placed into the RWST.

As a result, the quantity of radioactive material contained in the RWST exceeded the Technical Specification 3.9.A.5.a. permissible limit of 10 curies. At the time, radiochemistry sampling of the RWST indicated an activity of.262 uCi/cc resulting in 42.33 curies.

In accordance with Technical Specification 3.9.A.5.b, the addition of radioactive liquid to the RWST was immediately suspended, and actions were taken to reduce the curie content below the limit.

The cause for this condition was attributed to inadequate radiochemistry sampling of the RCS during the draindown.

H-1