Inservice Inspection Program Relief Request HC-RR-B12
ML031130004
Person / Time
Site: Hope Creek 
Issue date: 04/14/2003
From: Salamon G
Public Service Enterprise Group
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
LRN-03-0080
Download: ML031130004 (6)


Text

PSEG Nuclear LLC P.O Box 236, Hancocks Bndge, New Jersey 08038-0236 APR 1 4 2003 0 PSEG Nuclear LLC LRN-03-0080 United States Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 INSERVICE INSPECTION PROGRAM RELIEF REQUEST HC-RR-B12 HOPE CREEK GENERATING STATION FACILITY OPERATING LICENSES NPF-57 DOCKET NOS. 50-354 Pursuant to 10 CFR 50.55a(a)(3), PSEG Nuclear, LLC (PSEG Nuclear) requests approval of the enclosed relief request. Approval for relief is requested in accordance with the hardship or unusual difficulty provisions of 10CFR50.55a(a)(3)(ii). In this instance, visual examination of the inner radius is limited by physical obstructions.

PSEG Nuclear wishes to use the proposed alternative to the required volumetric examination for nozzles in lieu of the existing ASME Section XI Table IWB-2500-1, Examination Category B-D, Item B3.100. Compliance with the proposed alternatives will provide an adequate level of quality and safety for examination of the affected areas.

The attachment to this letter includes the proposed alternative and supporting justification for the relief. Based on the evaluation contained in the attachment, PSEG Nuclear has concluded that the proposed alternative provides an acceptable level of quality and safety. Accordingly, this proposal satisfies the requirements of 1 OCFR50.55a(a)(3)(ii).

This relief request is applicable to PSEG Nuclear Hope Creek Generating Station.

PSEG Nuclear requests that the NRC approve this request by May 2003 in order to support Hope Creek refueling outage RF1 1 scheduled to commence April 12, 2003.

Should you have any questions regarding this request, please contact Mr. Howard Berrick at 856-339-1862.

Sincel G.

alamon Manager - Nuclear Safety and Licensing

Attachment:

ISI Relief Request HC-RR-B12 95-2168 REV 7/99

Document Control Desk APR 1 4 2003 LRN-03-0080 C

Mr. H. Miller, Administrator Regional Administrator - Region I U. S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 U. S. Nuclear Regulatory Commission ATTN: Mr. G. Wunder Licensing Project Manager - Hope Creek Mail Stop 08B1 Washington, DC 20555-001 USNRC Senior Resident Inspector-Hope Creek (X24)

Mr. K. Tosch, Manager IV Bureau of Nuclear Engineering P. O. Box 415 Trenton, NJ 08625

Document Control Desk Attachment I LRN-03-0080 Relief Request HC-RR-B12 ASME Code Component Affected Alternative Exam Requirements for Inner Radius Examination of Class 1 Reactor Pressure Vessel (RPV) Nozzles. [See Table 1 below]

Applicable ASME Code Edition and Addenda ASME Section Xl, 1989 Edition, is the code of record for PSEG Nuclear LLC (PSEG Nuclear) Hope Creek Nuclear Generating Station's Second Ten-Year ISI Program Interval.

Applicable Code Requirement

Conduct volumetric examinations of Hope Creek Nuclear Generating Station RPV Nozzle Inside Radius Sections in accordance with ASME Section Xl 1989 Edition IWB-2500-1 requirements for Class 1 Examination Category B-D, Item B3.100, Figures IWB-2500-7 (a) through (d).

Proposed Alternative Pursuant to 10 CFR 50.55a(a)(3)(ii), PSEG Nuclear LLC proposes to perform an enhanced VT-1 visual examination technique of the surface M-N shown in ASME Section Xl Figures IWB-2500-7 (a) through (d) as an alternative to ASME Section Xl Table IWB-2500-1, Examination Category B-D, Item B3.100 requiring volumetric examination (Ultrasonic, UT) of the Inner Radius of Class 1 Reactor Vessel Nozzles.

The enhanced remote visual examination will be performed upon the examination surface M-N to achieve essentially 40-60% coverage using 8x magnification video equipment to examine the inner radii. The resolution sensitivity for this remote examination will be established using a 1-mil diameter wire standard similar to that used for other reactor pressure vessel internal examinations intended to detect cracking.

Reactor vessel closure head vent and spray nozzles inner radii will receive direct visual examinations (VT-1) conducted in accordance with ASME Xl requirements, while the other remaining aforementioned components will receive enhanced visual examinations using the 1-mil diameter wire standard.

Crack-like surface flaws exceeding the acceptance criteria of Table IWB-3512-1 are unacceptable for continued service unless the reactor vessel meets the requirements of IWB-3142.2, 1WB-3142.3 or IWB-3142.4.

Proposed Alternative In Accordance with 10 CFR 50.55a(a)(3)(ii)

- Hardship or Unusual Difficulty without Compensating Increase in Level of Quality and Safety -

Page 1 of 4

Document Control Desk LRN-03-0080 Attachment I Relief Request HC-RR-B12 Basis for Relief I

The following Hope Creek RPV Nozzle Inner radius exams listed below contain configurations that impede complete 100 percent visual examination coverage of the nozzle inner radius area surface M-N.

Table I Hope Creek RPV Nozzle Inner Radius Exams Summary Component Estimated Limitation Configuration Number Identification Coverage 100195 RPV1-N2A 50%

Thermal Sleeve/Jet Pump Riser 100200 RPV 50%3600 Recirculation Inlet Nozzle 100200 RPV1-N2B 50%

Thermal Sleeve/Jet Pump Riser 600 Recirculation Inlet Nozzle 100210 RPV1-N2C 50%

Thermal Sleeve/Jet Pump Riser 10025 RPI-N2 50%900 Recirculation Inlet Nozzle 100210 RPV1-N2D 50%

Thermal Sleeve/Jet Pump Riser

___________1200 RecirculationInlet Nozzle Thermal Sleeve/Jet Pump Riser 100215 RPVI-N2E 50%

1500 Recirculation Inlet Nozzle 100220 RPV1-N2F 50%

Thermal Sleeve/Jet Pump Riser 2100 Recirculation Inlet Nozzle 100225 RPVI-N2G 50%

Thermal Sleeve/Jet Pump Riser 10025 RPI-N2 50%2400 Recirculation Inlet Nozzle Thermal Sleeve/Jet Pump Riser 100230 RPV-N2H 50%

32700 Recirculation Inlet Nozzle 100235 RPV1-N2J 50%

Thermal Sleeve/Jet Pump Riser

___________3000 RecirculationInlet Nozzle 1002400 RPV1-N2 40%

Thermal Sleeve/Jet Pump Riser 100320 RPV-N 50%

112.3300 Recirculation Inlet Nozzle 100295 RPVC-N5A 40%

Thermal Sleeve/land Sparger 1200 Core Spray Inlet Nozzle 100300 RPV1-N5B 40%

Thermal Sleeve/land Sparger

___________2400 CoreSprayInletNozzle 100320 RPV1-N8A 60%

Instrumentation Lines 1 2.50- Jet Pump Instrumentation Nozzle 100325 RPV1-N8B 60%

Instrumentation Lines 292.50- Jet Pump Instrumentation Nozzle Thermal Sleeve/ Collar & Bolt Assembly 100400 RPVI-N17A 50%

1450 LPCI Inlet Nozzle 10041 RV1-N7I350%Thermal Sleeve/ Collar & Bolt Assembly 10041 RVI-I7B50%1350 L-PCI Inlet Nozzle 10040 RPV-N17 50%Thermal Sleeve/ Collar & Bolt Assembly 10040 RPV-N17 50%2250 LPCI Inlet Nozzle 10040 RPV-N17 50%Thermal Sleeve/ Collar & Bolt Assembly 10040 RPV-NI7 50%3150 LPCI Inlet Nozzle Proposed Alternative In Accordance with 10 CFR 50.55a(a)(3)(ii)

- Hardship or Unusual Difficulty without Compensating Increase in Level of Quality and Safety -

Page 2 of 4

Document Control Desk Attachment I LRN-03-0080 Relief Request HC-RR-B12 Visual examination of the inner radius region for the subject nozzles is limited because reactor internal piping configuration prevents placement of the camera in all positions necessary to examine surface M-N over the full circumference.

The specific nozzle limitations and estimated coverage are indicated in Table 1.

Performance of the volumetric examination results in significant personnel radiation exposure and does not result in a significant increase in the level of plant quality or safety. The redesign and construction of these nozzles and associated thermal sleeves would result in a hardship and unusual difficulty without compensating increase in level of quality or safety.

Performance of the volumetric examination requires the examiner to enter and remain inside the biological shield penetration area around the nozzle for the duration of the ultrasonic examination that takes approximately 1.5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br />. Dose rates for the specified RPV nozzles are in the range of 200 mr/hr to 250 mr/hr with shielding in place. Performance of these examinations results in an estimated personnel exposure of about 3.5 Rem per inspection interval.

Performance of a visual examination using remote cameras essentially eliminates any personnel exposure. The implementation of this relief request should reduce vessel examination time by approximately 18 hours2.083333e-4 days <br />0.005 hours <br />2.97619e-5 weeks <br />6.849e-6 months <br />, which translates to significantly reduced personnel radiation exposure and cost savings.

All nozzle forgings were nondestructively examined during fabrication and have been previously examined using ultrasonic techniques specific to the nozzle configuration. No indications of fabrication or service related cracking have been observed as result of these exams.

Nozzle inner radius examinations are the only non-welded areas requiring examination on the RPV. This requirement was deterministically made early in the development of ASME Section Xl, and applied to 100 percent of nozzles welded with full penetration welds. Fatigue cracking is the only applicable degradation mechanism for the nozzle inner radius region. For all nozzles other than feedwater, there is no significant thermal cycling during operation.

Therefore from a risk perspective there is no need to perform volumetric examination on any nozzles other than feedwater or operational Control Rod Drive (CRD) returns. No service related cracking has been discovered in any of the Boiling Water Reactor (BWR) fleet plant nozzles other than feedwater and operational CRD returns. The six feedwater nozzle inner radius sections will continue to be examined in accordance with UT techniques developed and qualified with GE-NE-523-A71-0594-A Revision 1 (the NRC has approved this report under TAC No. MA6787). PSEG Nuclear believes that application of a visual examination alternative for the listed nozzle inner radius regions ensures an acceptable level of quality and safety.

Proposed Alternative In Accordance with 10 CFR 50.55a(a)(3)(ii)

- Hardship or Unusual Difficulty without Compensating Increase in Level of Quality and Safety -

Page 3 of 4

Document Control Desk Attachment I LRN-03-0080 Relief Request HC-RR-B12 In an internal Nuclear Regulatory Commission (NRC) memorandum (Reference No. 1), the staff indicated that an ultrasonic examination could be replaced by a VT-1 visual examination of the proposed nozzle inspections on the basis that the surveillance is being maintained and a VT-1 visual examination is completed.

Note: For Table IWB-3512-1, the depth of a crack indication is assumed to be one half of the measured length of the crack indication. As previously stated, crack-like surface flaws found exceeding the acceptance criteria of Table IWB-3512-1 are unacceptable for continued service unless the reactor vessel meets the requirements of IWB-3142.2, IWB-3142.3 or IWB-3142.4.

Based on the above, PSEG Nuclear believes that the proposed alternative to perform an enhanced VT-1, visual examination technique of the surface M-N shown in ASME Section XI Figures IWB-2500-7 (a) through (d) in lieu of ASME Section Xl Table IWB-2500-1, Examination Category B-D, Item B3.100 requiring volumetric examination (Ultrasonic - UT) of the Inner Radius of Class 1 Reactor Vessel Nozzles provides reasonable assurance of structural integrity.

Duration of Proposed Alternative Hope Creek - Second Ten-Year Interval (ASME Xl, 1989 Edition)

Precedence Previous relief has been granted to Detroit Edison Company, Fermi Unit 2, Docket No. 50-341, TAC No. MB2166 and MB2755 dated October 5, 2001].

References

1. NRC internal memorandum from K.R. Wichman (NRC) to W.H. Bateman (NRC) dated May 25, 2000;

Subject:

'The Third Meeting with the Industry to discuss the elimination of RPV Inner Radius Inspection (ML003718630).

2. Code Case N-648, Alternative Requirements for Inner Radius Examinations of Class 1 Reactor Vessel NozzlesSection XI, Division 1.

Proposed Alternative In Accordance with 10 CFR 50.55a(a)(3)(ii)

- Hardship or Unusual Difficulty without Compensating Increase in Level of Quality and Safety -

Page 4 of 4