PSEG Nuclear LLC P.O. Box 236, Hancocks Bridge, New Jersey 08038-0236 T PSEG MAY 1 5 2003 NuclearLLC LRN-03-0232 United States Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 SUPPLEMENTAL INFORMATION FOR RELIEF REQUEST HC-RR-Bl I HOPE CREEK GENERATING STATION FACILITY OPERATING LICENSE NPF-57 DOCKET NO. 50-354 On April 14, 2003, PSEG Nuclear requested relief (HC-RR-Bl1) from the requirements of ASME Section Xl 1989 Edition, Table IWB-2500-1, Examination Category. B-D, Item B3.100, in order to implement the alternative requirements of an enhanced VT-1, visual examination technique of the surface M-N shown in ASME Section Xl, Figures IWB-2500-7 (a) through (d) as an alternative to ASME Section Xl Table IWB-2500-1, Examination Category B-D, Item B3.100 that required volumetric examination (Ultrasonic, UT) of the Inner Radius of Class 1 Reactor Vessel Nozzles. The request for relief is for the second 10-year inservice inspection (ISI) interval.

On May 14, 2003, a telecon was held between the NRC and PSEG to further discuss the relief request. As a result of this telecon, PSEG is submitting the following supplemental information to support the completion of the NRC Staffs review of relief request HC-RR-Bl 1.

Enhanced visual resolution demonstrations (EVT-1) for reactor vessel nozzle inner radii will qualify the examination parameters. These parameters will remain consistent with the subsequent EVT-1 examinations. The following parameters should be considered during qualification and examination of EVT-1 nozzle inner radii exams:

Lighting Field of view Magnification Depth of Field Speed of camera movement during examination 95-2168 REV. 7/99

Document Control Desk 2

MAY 1 5 2003 LRN-03-0232 Should you have any questions regarding this submittal please contact Brian Thomas at 856-339-2022.

Sincerely, G. Salamon Manager - Nuclear Safety and Licensing C

Mr. H. J. Miller, Regional Administrator U. S. Nuclear Regulatory Commission - Region I 475 Allendale Road King of Prussia, PA 19406 U. S. Nuclear Regulatory Commission ATTN: Mr. G. Wunder, Licensing Project Manager - Hope Creek Mail Stop 08B1 Washington, DC 20555 USNRC Senior Resident Inspector - Hope Creek (X24)

Mr. K. Tosch, Manager, IV Bureau of Nuclear Engineering P.O. Box 415 Trenton, NJ 08625