FINAL AS-ADMINISTERED WALKTHROUGH JPMS FOR THE DUANE ARNOLD EXAMINATION - NOVEMBER 2002

QF-1030-11 Rev. 1 (FP-T-SAT-30) 1"...

JOB PERFORMANCE MEASURE (JPM)

Committed to Nuclear Excellence "SITE:

DAEC TASK TITLE:

JPM NUMBER:

RELATED PRA INFORMATION:

TASK NUMBERS:

K/A NUMBERS:

SLOI Recirc power reduction/ Recirc MG lube oil high temperature alarm/Recirc pump trip/Scram 202002-xx REV.

0 100.19 Respond to Loss of Two Reactor Recirculation Pumps 202002 A4.09(3.2/3.3) 2.1.32(3.4/3.8) 2.1.33(3.4/4.0) 2.2.22(3.4/4.1)

APPLICABLE METHOD OF TESTING:

1 EVALUATION LOCATION:

Discussion:

In-Plant:

Simulator:

FI]

Simulate/walkthrough:

Control Room:

Other:

Time for Completion:

10 Minutes Time Critical:

Alternate Path /

/

Faulted:

YES TASK APPLICABILITY:

SROIRO Additional signatures may be added as needed.

Instructor Vafldated bry "Validation Instructor (See JPM Validation Checklist, Attachment 1)

Retention: Life of policy + 1 Qyrs.

Retain in: Training Program File Disposition: Reviewer and Approver Page 1 of 11 7

Perform: w 7 Ei--

NO Date

,*,,/izZIAO "-2 v

v ff 4=-,4r=#vj I

'Y' /. 0

QF-1030-11 Rev. 1 (FP-T-SAT-30)

Retention: Li"e OT poiicy + lUyrs.

Retain in: Training Program File Disposition: Reviewer and Approver Page 2 of 11

QF-1 030-11 Rev. I (FP-T-SAT-30)

JPM 202002-xx, SLO/ Recirc power reduction/ Recirc MG lube oil high temperature alarm/Recirc pump trip/Scram, Rev. 0 JPM Number:

202002-xx JPM

Title:

SLO/ Recirc power reduction/ Recirc MG lube oil high temperature alarmlRecirc pump trip/Scram Examinee:

Job

Title:

Start Time Evaluator:

Date:

Finish Time PERFORMANCE RESULTS:

SAT:ZIZ UNSAT:ZIZ COMMENTS/FEEDBACK: (Comments shall be made for any steps graded unsatisfactory).

EVALUATOR'S SIGNATURE:

NOTE: Only this page needs to be retained in examinee's record if completed satisfactorily. If unsatisfactory performance is demonstrated, the entire JPM should be retained.

Page 3 of 10

QF-1030-11 Rev. 1 (FP-T-SAT-30)

JPM 202002-xx, SLO/ Recirc power reduction/ Recirc MG lube oil high temperature alarm/Recirc pump trip/Scram, Rev. 0 I will explain the initial conditions, which step(s) to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this job performance measure will be satisfied.

DURING THE JPM, ENSURE PROPER SAFETY PRECAUTIONS, FME, AND/OR RADIOLOGICAL CONCERNS AS APPLICABLE ARE FOLLOWED.

INITIAL CONDITIONS:

"* The plant is in single loop with the "B" Recirc Loop in operation.

"* The "A" Recirc Pump was removed from service two days ago due to high vibrations.

Power is being lowered for plant shutdown to inspect the "A" Recirc Pump.

Assume all single loop STPs have been performed satisfactorily.

INITIATING CUES (IF APPLICABLE):

The OSS directs you to reduce power 30 MWE at 2 to 5 MWe/minute with the "B" Recirc MG.

Page 4 of 10 JPM BRIEFING/TURNOVER Add required site specific JPM briefing material here:

i.e., This section is read once for the entire package of JPMs. It is not required to review this section for every JPM being performed in the package. The initial conditions and initiating cue(s)/tasks to be performed should be read and then provided to the examinee.

You may use any approved reference materials normally available including logs. Make all written reports, oral reports, and log entries as if the evolution is actually being performed.

EOP Immediate Actions are required to be performed from memory. After completing immediate action steps without using the procedure, you may then use any approved reference materials.

If this JPM is performed on the simulator, the JPM administrator should only give cues that are not indicated on the simulator. If simulator indication is sufficient to indicate the completion of a step, the JPM administrator should not have to give a cue to the trainee to continue the evolution.

I

QF-1030-11 Rev. I (FP-T-SAT-30)

JPM 202002-xx, SLO/ Recirc power reduction/ Recirc MG lube oil high temperature alarm/Recirc pump trip/Scram, Rev. 0 JPM PERFORMANCE INFORMATION Required Materials:

General

References:

Task Standards:

ARP 1 C04A B-9 Rev 2 01 264 Rev 70 T.S. 3.4.1 Recirc. Loops Operating

1. Recirc pump speed reduced.
2. Loss of both Recirc pumps identified.
3. Manual scram pushbuttons depressed.

Start Time:

NOTE: Critical steps are marked with a "Y" below the performance step number. Failure to meet the standard for any critical step shall result in failure of this JPM.

Performance Step:

At 1C04, reduce "B" MG Set speed control.

Critical: Y Standard:

"B" MG Set Control knob turned counterclockwise to commence power reduction.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

Page 5 of 10

QF-1030-11 Rev. I (FP-T-SAT-30)

JPM 202002-xx, SLO/ Recirc power reduction/ Recirc MG lube oil high temperature alarm/Recirc pump trip/Scram, Rev. 0

=Performance Step:

Critical: N IStandard:

Performance:

Comments:

Performance Step:

Critical: N Standard:

Performance:

A Comments:

Monitor Recirc Loop Flows and Core Flow.

Any or all of the following indications monitored:

FI-4523 A Loop Flow FI-4526 B Loop Flow FR-4528 Total Core Flow B012 Total Core Flow SATISFACTORY UNSATISFACTORY Continue to reduce recirc speed in at <5 MWe/min.

Commences power reduction with Recirc Flow at <5 MWe/min.

(At this point ARP 1C04A B-9 "B" Recirc MG Fluid Drive Oil HI Temp" will Alarm)

SATISFACTORY UNSATISFACTORY Booth Instructor:

(Following 2 Recirc Flow reductions or directions from the Floor Instructor)

Insert Annunciator Alarm 1C04A B-9 Insert override: lc04a(18) ON ET:

Performance Step:

Critical: N Standard:

Inform OSS of 1 C04A B-9 and pull the ARP.

Inform OSS "B" Recirc MG Fluid Drive Oil HI Temp" is alarming Pull and review ARP 1 C04A B-9 for actions.

Performance:

Comments:

SATISFACTORY UNSATISFACTORY Note: If the operator inserts a Manual SCRAM any time following this alarm the last critical task to SCRAM the Reactor should be considered completed satisfactory.

Page 6 of 10

QF-1030-11 Rev. I (FP-T-SAT-30)

JPM 202002-xx, SLO/ Recirc power reduction/ Recirc MG lube oil high temperature alarm/Recirc pump trip/Scram, Rev. 0 Simulator Booth Instructor:

When the candidate starts to go to 1C21 (back panels) or as directed by the Evaluator:

Insert Malfunction ET Performance Step:

Critical: N Standard:

Performance:

Comments:

rr06b RECIRC M-G DRIVE MOTOR BREAKER TRIP-M-G B Identify loss of both Recirc pumps.

Recognition that both Recirc pumps have tripped.

SATISFACTORY UNSATISFACTORY Cue: If the operator requests permission to manually scram the Reactor, act as the OSS and grant permission.

I



-

Prerormance Step:

Critical: Y Standard:

Manually :Scram the Reactor.

Manual Scram Pushbuttons depressed.

Performance:

Comments:

SATISFACTORY UNSATISFACTORY If the operator inserts a Manual SCRAM any time after the High Temperature alarm is received this would be considered satisfactory completion for this step.

Cue that JPM is now complete.

Terminating Cues:

When Manual Scram Pushbuttons have been depressed.

Stop Time:

Page 7 of 10 I

QF-1030-11 Rev. I (FP-T-SAT-30)

JPM 202002-xx, SLO/ Recirc power reduction/ Recirc MG lube oil high temperature alarm/Recirc pump trip/Scram, Rev. 0 SIMULATOR SET UP:

Reset to IC 20 or comparable IC to ensure SLO and power reduction will not be in the Buffer or Exclusion region of the Power to Flow Map..

Secure the "A" Recirc pump.

If desired, once conditions stabilize snap to IC 0 and save as IC _

to be used during the JPM setup.

SIMULATOR EVENT TRIGGERS:

Set Event Triggers as needed for the simulator malfunctions.

SIMULATOR MALFUNCTIONS:

Booth Instructor: Following 2 Recirc Flow reductions or directions from the Floor Instructor Insert Annunciator Alarm for IC04A B-9 Insert override: lc04a(18) ON ET:

T Booth Instructor: When the operator says or starts to go to 1C21 the "B" Recirc MG will trip placing the plant in natural circ.

(Or as directed by the Floor Instructor)

Insert Malfunction rr06b RECIRC M-G DRIVE MOTOR BREAKER TRIP-M-G B ET SIMULATOR OVERRIDES:

None SIMULATOR REMOTE FUNCTIONS:

None Page 8 of 10

QF-1030-11 Rev. 1 (FP-T-SAT-30)

TURNOVER SHEET INITIAL CONDITIONS:

The plant is in single loop with the "B" Recirc Loop in operation.

The "A" Recirc Pump was removed from service two days ago due to high vibrations.

Power is being lowered for plant shutdown to inspect the "A" Recirc Pump.

Assume all single loop STPs have been performed satisfactorily.

INITIATING CUES (IF APPLICABLE):

0 The OSS directs you to reduce power 30 MWE at 2 to 5 MWe/minute with the "B" Recirc MG.

Page 9 of 10

QF-1030-11 Rev. I (FP-T-SAT-30)

JPM 202002-xx, SLO/ Recirc power reduction/ Recirc MG lube oil high temperature alarm/Recirc pump trip/Scram, Rev. 0 ATTACHMENT I JOB PERFORMANCE MEASURE VALIDATION CHECKLIST ALL STEPS IN THIS CHECKLIST ARE TO BE PERFORMED UPON INITIAL VALIDATION AND PRIOR TO USE.

REVIEW STATEMENTS YES NO N/A

1.

Are all items on the signature page filled in correctly?

El El El

2.

Has the JPM been reviewed and validated by SMEs?

F El]

El

3.

Can the required conditions for the JPM be appropriately El El El1 established in the simulator if required?

4.

Does the performance steps accurately reflect trainee's actions in El El El accordance with plant procedures?

5.

Is the standard for each performance item specific as to what El El El controls, indications and ranges are required to evaluate if the trainee properly performed the step?

6.

Has the completion time been established based on validation data El El El or incumbent experience?

7.

If the task is time critical, is the time critical portion based upon El El El actual task performance requirements?

8.

Is the Licensee level appropriate for the task being evaluated if El El El required?

9.

Is the K/A appropriate to the task and to the licensee level if El El El required?

10.

Have the performance steps been identified and typed (Critical /

El El El Sequence / Time Critical) appropriately?

11.

Have all special tools and equipment needed to perform the task El El El been identified and made available to the trainee?

12.

Are all references identified, current, accurate, and available to the El El El trainee?

13.

Have all required cues (as anticipated) been identified for the El El El evaluator to assist task completion?

All questions/statements must be answered "YES" or the JPM is not valid for use. If all questions/statements are answered "YES" then the JPM is considered valid and can be performed as written. The individual(s) performing the validation shall sign and date this form.

Validation Personnel /Date Validation Personnel /Date Validation Personnel /Date Validation Personnel/Date Validation Personnel/Date Validation Personnel/Date Page 10 of 10

D UANE ARNOLD ENERGY CENTER JOB PERFORMANCE MEASURE NUMBER: 239001-02 TASK NUMBER:

95.15 TITLE: Install EOP Defeat 5 to depressurize the reactor Rev. 1 DEVELOPED BY:

VALIDATED BY:

Instriirtnr istructor REVIEWED BY:

APPROVED BY:

Plant Reviewer "training Supervisor-Operatis '

Date /.

Date Date Date Date TDT-3.08 Rev. 4 ructor

DUANE ARNOLD ENERGY CENTER JOB PERFORMANCE MEASURE JPM No. 239001-02 JPM

Description:

Install EOP Defeat 5 to depressurize the reactor.

Task No. 95.15 Task

Description:

Perform the required actions of the MSIV and Main Steam Line Drain Total Isolation Defeat.

K/A

Reference:

A4.02 3.2/3.2 239001 APPLICABLE METHOD OF TESTING:

Simulate Performance Actual Performance X

Simulator X

In-Plant Control Room Time for Completion: 10 minutes 2 39001-02_jpm.doc JPM 239001-02 Rev.1 I

-1I-

JOB PERFORMANCE MEASURE VALIDATION CHECKLIST NOTE All steps of this checklist should be performed upon initial validation. Prior to JPM usage, revalidate JPM using steps 7 through 10.

JPM No. 239001-02 JPM Title Install EOP Defeat 5 to depressurize the reactor.

1.

Task description and number, JPM description and number are identified S2.

Task elements identified and K/A references are included

3.

Performance location specified

a.

in-plant

b.

control room

c.

simulator

4.

Initial conditions and cues identified

a.

setup, required materials, and procedure

b.

malfunctions and instructor actions

c.

initiating and terminating cues

5.

Task standards identified and verified by SME review S6.

Critical tasks/steps identified meet criteria and identified with a "C"

7.

Verify JPM steps fit the most currenq procedures Procedure Rev. -L Date 9

8.

Pilot test JPM 0...'

a.

verify cues both verbal and visual are free of conflict

b.

ensure performance time is accurate

9.

If the JPM cannot be performed as written with proper responses, then revise the JPM

10. When JPM is revalidated, SME/Instructor signs and dates JPM SME/Instructor Date SME/Instructor Date SME/Instructor Date 2001B3 JPM 239001-02 Rev. I

SIMULATOR SETUP:

EVENT TRIGGERS None MALFUNCTIONS:

Time Malfunction Malfunction ET Delay F. Sev. Ramp I. Sev.

No.

Title 0

AD01D PSV-4403 leak N/A 0

7%

0 0

0 SW24 WW load N/A 0

100%

0 0

blockage OVERRIDES:

Time Override Tag Override Description ET Delay Value.

Ramp 0

AD HS-4400 N/A 0

CLOSE 0

0 AD HS-4401 N/A 0

CLOSE 0

0 AD HS-4402 N/A 0

CLOSE 0

0 AD HS-4405 N/A 0

CLOSE 0

0 AD HS-4406 N/A 0

CLOSE 0

0 AD HS-4407 N/A 0

CLOSE 0

REMOTE FUNCTIONS:

None 2 3 9 001-02jpm.doc JPM 239001-02 Rev. 1 INSTRUCTOR ACTIONS:

1. Insert malfunctions and overrides.
2. Override ADS logic.
3. Place ADS handswitches in the OPEN position.
4. Allow 850 psig in RUN to cause a Group 1, then place the Mode Switch in the SHUTDOWN position.
5. Read initial conditions and initiating cues to the operator.

TASK STANDARDS:

1. HS-4427A placed in OVERRIDE position
2. HS-4427B placed in OVERRIDE position
3. HS-4427C placed in OVERRIDE position
4. HS-4427D placed in OVERRIDE position
5. All MSIV handswitches taken to CLOSE and PCIS reset
6. MO-1043 is OPEN
7. CV-1064 is OPEN
8. MO-4424 is OPEN
9. MO-4423 is OPEN REQUIRED MATERIALS:

EOP Defeat 5 GENERAL

REFERENCES:

EOP Defeat 5, Rev. 1, 2/16/1999 JPM 239001-02 239001-02_jpm.doc Rev. 1

Read to the operator the following information:

239001-02-jpm.doc JPM 239001-02 Rev. 1 INITIAL CONDITIONS:

1.

The reactor scrammed due to a safety relief valve failing open.

2.

The Mode Switch was NOT taken out of RUN prior to 850 psig.

3.

DW temperature is 280 degrees F.

4.

Emergency Depressurization has been directed.

5.

All SRVs have failed.

6.

You are the BOP operator.

INITIATING CUES:

The OSS directs you to perform the required actions of EOP Defeat 5 in order to depressurize the RPV with the Main Steam Line Drains.

This task is not time critical.

Inform the evaluator when you have completed the task.

PERFORMANCE INFORMATION Time Start NOTE: The first four steps may be performed in any order.

PERFORMANCE STEP:

At Panel 1C15, place GROUP 1 CHANNEL Al ALL Critical: C SIGNALS OVERRIDE keylock switch HS-4427A in OVERRIDE and confirm amber light is ON.

STANDARD:

HS-4427A taken to OVERRIDE and the amber light is confirmed ON.

COMMENTS:

PERFORMANCE STEP:

At Panel 1C15, place GROUP 1 CHANNEL A2 ALL Critical: C SIGNALS OVERRIDE keylock switch HS-4427C in OVERRIDE and confirm amber light is ON.

STANDARD:

HS-4427C taken to OVERRIDE and the amber light is confirmed ON.

COMMENTS:

PERFORMANCE STEP:

At Panel 1C17, place GROUP 1 CHANNEL B1 ALL Critical: C SIGNALS OVERRIDE keylock switch HS-4427B in OVERRIDE and confirm amber light is ON.

STANDARD:

HS-4427B taken to OVERRIDE and the amber light is confirmed ON.

COMMENTS:

239001-02jpm.doc JPM 239001-02 Rev. 1I NOTE:

Critical steps are denoted with a "C". Failure to meet the standard for this step constitutes failure.

PERFORMANCE STEP:

At Panel 1C17, place GROUP 1 CHANNEL B2 ALL Critical: C SIGNALS OVERRIDE keylock switch HS-4427D in OVERRIDE and confirm amber light is ON.

STANDARD:

HS-4427D taken to OVERRIDE and the amber light is confirmed ON.

COMMENTS:

PERFORMANCE STEP:

Verify all MSIV handswitches are in CLOSE position.

Critical: C STANDARD:

All MSIV handswitches are in the CLOSE-position.

COMMENTS:

PERFORMANCE STEP:

Reset Group 1 using DIV 1 RESET and DIV 2 RESET Critical: C pushbuttons on 1C05.

STANDARD:

PCIS is reset using the DIV 1 and DIV 2 pushbuttons.

COMMENTS:

PERFORMANCE STEP:

At 1C04, open MO-1043 MSL HEADER DRAINS BYPASS Critical: C valve.

STANDARD:

MC-1043 is open.

COMMENTS:

PERFORMANCE STEP:

At 1C04, verify CLOSED, MO-1044 MSL DRAIN ORIFICE Critical:

BYPASS valve.

STANDARD:

MO-1044 is verified CLOSED.

COMMENTS:

PERFORMANCE STEP:

At 1C04, open CV-1064 MSL HEADER DRAIN valve by Critical: C placing HS-1064 in OPEN position.

STANDARD:

CV-1064 is OPEN.

COMMENTS:

JPM 239001-02 Rev. 1 239001-02jpm.doc PERFORMANCE STEP:

At 1C04, open MO-4424 OUTBD MAIN STM LINE DRAIN Critical: C ISOL valve by placing handswitch HS-4424 in OPEN position.

STANDARD:

MO-4424 is OPEN.

COMMENTS:

PERFORMANCE STEP:

At 1C03, open MO-4423 INBD MAIN STM LINE DRAIN Critical: C ISOL valve by placing handswitch HS-4423 in OPEN position.

STANDARD:

MO-4423 is OPEN.

COMMENTS:

PERFORMANCE STEP:

At 1C04, open MO-1044 MSL DRAIN ORIFICE BYPASS Critical:

as necessary to vent the RPV.

STANDARD:

MO-1044 is opened.

COMMENTS: CUE: If asked if opening MO-1044 is necessary, direct the operator to open MO-1044.

Time Stop TERMINATING CUES: All 4 Override switches taken to OVERRIDE and MSL Drain valves are open.

JPM 239001-02 239001-02_jpm.doc Rev. 1

239001-02 VERIFICATION OF COMPLETION JPM

Description:

Install EOP Defeat 5 to depressurize the reactor.

Evaluator:

Licensee:

RO RO SRO F-] SRO Cert sTA

[II NSPEO Result:

F-1 SATISFACTORY F-1 UNSATISFACTORY COMMENTS/FEEDBACK: (Note any trainee discrepancies or misperformed steps.)

Evaluator's Signature 239001-02_jpm.doc Date JPM 239001-02 Rev. 1 JPM No.:

Operator:

QF-1030-11 Rev. I (FP-T-SAT-30)

Nl!l JOB PERFORMANCE MEASURE (JPM)

Committed to Nctear cen SITE:

TASK TITLE:

JPM NUMBER:

RELATED PRA INFORMATION:

TASK NUMBERS:

K/A NUMBERS:

DAEC RESTART OF A REACTOR FEED PUMP FOLLOWING A REACTOR SCRAM Using 01 644 QRC 1 259001-11 REV.

2 45.03 A4.02 (3.9/3/7)

Lb APPLICABLE METHOD OF TESTING:

Discussion:

EVALUATION LOCATION:

In-Plant:

Simulator:

LII Simulate/walkthrough:

Control Room:

Other:

Perform: I-(

Time for Completion:

Alternate Path /

Faulted:

TASK APPLICABILITY:

10 Minutes Time Critical:

NO RO/SRO Retention: Lite of policy + lOyrs.

Retain in: Training Program File Disposition: Reviewer and Approver Page 1 of 12 NO I

QF-1030-11 Rev. 1 (FP-T-SAT-30) 259001-11, RESTART OF A REACTOR FEED PUMP FOLLOWING A REACTOR SCRAM Using 01 644 QRC 1, Rev 2 JPM Number:

JPM

Title:

259001-11 RESTART OF A REACTOR FEED PUMP FOLLOWING A REACTOR SCRAM Using 01644 QRC 1 Examinee:

Job

Title:

Start Time Evaluator:

Date:

Finish Time PERFORMANCE RESULTS:

SAT: I I

UNSAT:

IZ COMMENTS/FEEDBACK: (Comments shall be made for any steps graded unsatisfactory). I EVALUATOR'S SIGNATURE:

NOTE: Only this page needs to be retained in examinee's record if completed satisfactorily. If unsatisfactory performance is demonstrated, the entire JPM should be retained.

Page 2 of 12

QF-1030-11 Rev. I (FP-T-SAT-30) 259001-11, RESTART OF A REACTOR FEED PUMP FOLLOWING A REACTOR SCRAM Using 01 644 QRC 1, Rev 2 I will explain the initial conditions, which step(s) to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this job performance measure will be satisfied.

DURING THE JPM, ENSURE PROPER SAFETY PRECAUTIONS, FME, AND/OR RADIOLOGICAL CONCERNS AS APPLICABLE ARE FOLLOWED.

INITIAL CONDITIONS:

A reactor scram has occurred.

IPOI 5 has been entered and immediate actions have been taken.

EOP 1 has been entered.

Both feedwater pumps tripped when reactor water level exceeded 211".

"* The S/U Feed Reg Valve is tagged out for maintenance.

"* The scram occurred four (4) minutes ago.

"* You are the 1C05 operator.

INITIATING CUES (IF APPLICABLE):

As the OSS, I direct you to Start the "B" (Bravo) Reactor Feed Pump and restore level to 170 to 211 inches using 01 644 QRC 1.

Page 3 of 12 JPM BRIEFING/TURNOVER Add required site specific JPM briefing material here:

i.e., This section is read once for the entire package of JPMs. It is not required to review this section for every JPM being performed in the package. The initial conditions and initiating cue(s)/tasks to be performed should be read and then provided to the examinee.

You may use any approved reference materials normally available including logs. Make all written reports, oral reports, and log entries as if the evolution is actually being performed.

EOP Immediate Actions are required to be performed from memory. After completing immediate action steps without using the procedure, you may then use any approved reference materials.

If this JPM is performed on the simulator, the JPM administrator should only give cues that are not indicated on the simulator. If simulator indication is sufficient to indicate the completion of a step, the JPM administrator should not have to give a cue to the trainee to continue the evolution.

QF-1030-11 Rev. I (FP-T-SAT-30) 259001-11, RESTART OF A REACTOR FEED PUMP FOLLOWING A REACTOR SCRAM Using 01 644 QRC 1, Rev 2 JPM PERFORMANCE INFORMATION Required Materials:

General

References:

Task Standards:

01 644 QRC 1 01644 QRC 1

1. Verify that the Aux Oil Pumps are running.
2. Verify that the high reactor water level trips are reset.
3. Start "B" RFP.

Start Time:

NOTE:

When providing "Evaluator Cues"l to the examinee, care must be exercised to avoid prompting the examinee. Typically cues are only provided when the examinee's actions warrant receiving the information (i.e. the examinee looks or asks for the indication).

NOTE:

Critical steps are marked with a "Y" below the performance step number. Failure to meet the sta.ndard for any critical step shall result in failure of thlis JPM.

Performance Step:

Verify Feed Reg Valve Controllers (HC-1579 and HC-1621) are in Manual and Critical: N Closed.

Standard:

HC-1579 and HC-1621 verified to be in MANUAL and both FRVs verified to be closed.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

HC-1 622 is tagged out and will probably be marked N/A.

Page 4 of 12

QF-1030-11 Rev. I (FP-T-SAT-30) 259001-11, RESTART OF A REACTOR FEED PUMP FOLLOWING A REACTOR SCRAM Using 01 644 QRC 1, Rev 2 Performance Step:

Zritical: N Standard:

Performance:

Comments:

Performance Step:

Critical: Y Standard:

Performance:

Comments:

Verify at least one Condensate pump is running At least one Condensate pump is verified to be running SATISFACTORY UNSATISFACTORY The operator may choose to secure one of the Condensate pumps.

Verify RFP Aux Oil Pumps 1P2A and B running.

The operator will verify that 1 P2A and 1 P2B are running or will start the pumps as necessary.

SATISFACTORY UNSATISFACTORY Note: The operator is allowed to place the switches for the Aux oil pumps in start even though the pumps are running.

Page 5 of 12 Performance Step:

Verify CV-1 611, RFP Recirc Valve, closed.

Critical: N Standard:

The operator will verify that CV-1611 is closed.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

QF-1030-11 Rev. 1 (FP-T-SAT-30) 259001-11, RESTART OF A REACTOR FEED PUMP FOLLOWING A REACTOR SCRAM Using 01 644 QRC 1, Rev 2

'Performance Step:

Verify CV-1631, Startup Feed Line Block, open Critical: N Standard:

The operator may skip this step or mark the step N/A due to the tagout of the SUFRV.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

Performance Step:

Throttle open MO-1708, Condensate F/D Bypass Valve, for approximately 5 Critical: N seconds.

Standard:

The operator will open the Condensate Demin Bypass valve using HS-1 708 for approximately 5 seconds..

Performance:

SATISFACTORY UNSATISFACTORY Comments:

Performance Step:

Verify RFP/MN TURB HI LEVEL CH.A, B, C trips reset at 1C05.

Critical: Y Standard:

The operator will reset the RFP/MN HI LEVEL trips by pushing in the reset pushbuttons.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

Page 6 of 12

QF-1030-11 Rev. 1 (FP-T-SAT-30) 259001-11, RESTART OF A REACTOR FEED PUMP FOLLOWING A REACTOR SCRAM Using 01 644 QRC 1, Rev 2 I Performance Step:

Start Reactor Feed Pump 1 P-1 B.

Critical: Y Standard:

The operator will start the "B" Reactor Feed Pump using HS-1616.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

Performance Step:

Establish desired RPV injection by manually adjusting Feed Reg Valve Critical: N Controller HC-1621 or the Startup Feed Reg Valve Controller HC-1622.

Standard:

The operator will manually adjust HC-1621 to control injection.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

HC-1622 SUFRV controller is tagout an would not be used.

Performance Step:

Stop RFP Aux Lube Pump IP2B Critical: N Standard:

The operator will stop "B" RFP Aux Lube Oil pump and return the handswitch to AUTO.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

Page 7 of 12

QF-1030-11 Rev. I (FP-T-SAT-30) 259001-11, RESTART OF A REACTOR FEED PUMP FOLLOWING A REACTOR SCRAM Using 01 644 QRC 1, Rev 2 Performance Step:

Critical: N Standard:

Performance:

Comments:

When directed by the OSS, adjust the Feed Reg Valve Controllers to the desired RPV level control setpoint and return to AUTO.

The operator will manually control reactor water level with CV-1 621.

SATISFACTORY UNSATISFACTORY Cue: Restore reactor water level to 170" to 211".

If asked about shifting the controllers to AUTO reply, "When level is stable between 170 and 211 inches you may shift control to AUTO".

Terminating Cues:

"B" RFP running and the operator controlling level.

(Level does not have to be restored to 170 to 211 inches. The operator just has to demonstrate control of level)

SStop Time:

Page 8 of 12 I

QF-1030-11 Rev. 1 (FP-T-SAT-30) 259001-11, RESTART OF A REACTOR FEED PUMP FOLLOWING A REACTOR SCRAM Using 01 644 QRC 1, Rev 2

-3IMULATOR SET UP:

1. Reset to IC-14.
2. Start "B" Well Water pump and secure "D" Well Water pump.
3. Insert a manual scram.
4. Ensure that reactor water level exceeds 211", and then lower reactor water level to less than 200".
5. Perform appropriate steps of IPOI 5, with the exception of leaving both Condensate pumps running.
6. Hang a Warning Tag on the HC-1 622 "S/U FRY" and MO-1 631 "SUFRV Block Valve".
7. Place HC-1579 and HC-1621 in MANUAL. Place the Master feed Reg valve controller in MANUAL and close both feed reg valves.
8. Read initial conditions and initiating cues to the operator.

SIMULATOR EVANT TRIGGERS:

None SIMULATOR MALFUNCTIONS:

None SIMULATOR OVERRIDES:

None SIMULATOR REMOTE FUNCTIONS:

None Page 9 of 12

QF-1030-11 Rev. I (FP-T-SAT-30) 259001-11, RESTART OF A REACTOR FEED PUMP FOLLOWING A REACTOR SCRAM Using 01644 QRC 1, Rev 2 TURNOVER SHEET INITIAL CONDITIONS:

A reactor scram has occurred.

IPOI 5 has been entered and immediate actions have been taken.

EOP 1 has been entered.

Both feedwater pumps tripped when reactor water level exceeded 211" The S/U Feed Reg Valve is tagged out for maintenance.

The scram occurred four (4) minutes ago.

You are the 1 C05 operator.

INITIATING CUES (IF APPLICABLE):

As the OSS, I direct you to Start the "B" (Bravo) Reactor Feed Pump and restore level to 170 to 211 inches using 01 644 QRC 1.

Page 10 of 12

QF-1030-11 Rev. I (FP-T-SAT-30) 259001-11, RESTART OF A REACTOR FEED PUMP FOLLOWING A REACTOR SCRAM Using 01 644 QRC 1, Rev 2 ATTACHMENT 1 JOB PERFORMANCE MEASURE VALIDATION CHECKLIST ALL STEPS IN THIS CHECKLIST ARE TO BE PERFORMED UPON INITIAL VALIDATION AND PRIOR TO USE.

REVIEW STATEMENTS

YES, NO N/A
1.

Are all items on the signature page filled in correctly?

D-1 D]

2.

Has the JPM been reviewed and validated by SMEs?

II El

3.

Can the required conditions for the JPM be appropriately

[i D

established in the simulator if required?

4.

Does the performance steps accurately reflect trainee's actions in Ei D

accordance with plant procedures?

5.

Is the standard for each performance item specific as to what

[

El Eli controls, indications and ranges are required to evaluate if the trainee properly performed the step?

6.

Has the completion time been established based on validation data LI or incumbent experience?

7.

If the task is time critical, is the time critical portion based upon El El actual task performance requirements?

8.

Is the Licensee level appropriate for the task being evaluated if W

Ei]

El required?

1-1

9.

Is the K/A appropriate to the task and to the licensee level if Il El required?

10.

Have the performance steps been identified and typed (Critical /

El El Sequence / Time Critical) appropriately?

11.

Have all special tools and equipment needed to perform the task Eli

[1 been identified and made available to the trainee?

12.

Are all references identified, current, accurate, and available to the Eli El trainee?

13.

Have all required cues (as anticipated) been identified for the El

[]

evaluator to assist task completion?

All questions/statements must be answered "YES" or the JPM is not valid for use. If all questions/statements are answered "YES" then the JPM is considered valid and can be performed as written. The individual(s) performing the validation shall sign and date this form.

Validation Personnel /Datd Validation Personnel /Date Validation Personnel /Date Validation Personnel/Date Validation Personnel/Date Validation Personnel/Date Page 11 of 12

QF-1030-11 Rev. 1 (FP-T-SAT-30) 259001-11, RESTART OF A REACTOR FEED PUMP FOLLOWING A REACTOR SCRAM Using 01 644 QRC 1, Rev 2 Ialidation Personnel /Date Validation Personnel/Date Page 12 of 12

VE ARNOLD ENERGY CENTER JOB PERFORMANCE MEASURE NUMBER: 295024-06 TASK NUMBER:

95.28 TITLE: Containment Venting Irrespective of Radioactive Release (Alternate Path, Hard Pipe Vent)

Rev. 5 Pla s 1.,

DEVELOPED BY:

Date VALIDATED BY:

REVIEWED BY:

APPROVED BY:

SME/Instructor Plantever

?-b "rQ-0 Date Date Da e TDT-3.08 Rev. 4 Tra nf g Supervisor-Operations

DUANE ARNOLD ENERGY CENTER JOB PERFORMANCE MEASURE JPM No. 295024-06 JPM

Description:

Containment venting irrespective of radioactive release (Alternate Path, Hard Pipe Vent)

Task No. 95.28 Task

Description:

Vent the torus irrespective of rad release K/A

Reference:

EK3.07 (3.5/4.0) 295024 EAL.14 (3.4/3.5)

EA2.01 (4.2/4.4)

APPLICABLE METHOD OF TESTING: SRO/RO Simulate Performance Actual Performance X

Simulator X

In-Plant Control Room Time for Completion: 10 minutes 2 9 5024-06jpm.doc JPM 295024-06 Rev. 5

-1I-

JOB PERFORMANCE MEASURE VALIDATION CHECKLIST NOTE All steps of this checklist should be performed upon initial validation. Prior to JPM usage, revalidate JPM using steps 7 through 10.

JPM No. 295024-06 JPM Title Containment venting irrespective of radioactive release (Alternate Path, Hard Pipe Vent)

<TZ__

1. Task description and number, JPM description and number are identified
2.

Task elements identified and K/A references are included

3.

Performance location specified

a.

in-plant

b.

control room C. simulator

4.

Initial conditions and cues identified

a.

setup, required materials, and procedure

b.

malfunctions and instructor actions

c.

initiating and terminating cues

5.

Task standards identified and verified by SME review

6.

Critical tasks/steps identified meet criteria and identified with a "C"

7.

Verify JPM steps fit the most current procedures Procedure Rev..

Date 41k. -.

'L4W~. ko

8.

Pilot test JPM V',

sr

a.

verify cues both verbal and visual are free of conflict

b.

ensure performance time is accurate

9.

If the JPM cannot be performed as written with proper responses, then revise the JPM

10. When JPM is revalidated, SME/Instructor signs and dates JPM SME/Instructor Date '

SME/Instructor SME/Instructor 295024-06.jpm.doc Date Date JPM 295024-06 Rev. 5 vz""'

SIMULATOR SETUP:

Reset to IC-14, or equivalent.

EVENT TRIGGERS None MALFUNCTIONS:

JPM295024-06 Time Malfunction Malfunction Title ET Delay F. Sev. Ramp I. Sev.

No.

0 AD01D Reac Pres Rlf or Safety Vlv 1.00 180 Leak-PSV4403 (VI) sec.

0 PC13F Break-Disch Pip of

.8 PSV4407 into Torus Air Space. Adjust as necessary to get drywell pressure

>53 psig.

0 AD01H Reac Pres Rlf or Safety Vlv 1.00 60 sec.

Leak-PSV4407 (VI) set the malfunction as necessary to keep the drywell pressure >53 psig.

0 RP02A RPS EPA Breaker Trip RPS A EPA Bkr 0

AN 1C35B (D-03) Simulator IC35B(15)

Out of Bounds Annunciator 0

AN 1C35B (D-04) Simulator 1C35B(16)

Out of Bounds Annunciator 0

RH09D RHR MO-1905 Thermal Overload Breaker Trip OVERRIDES:

JPM295024-06 Time Override Tag Override Description ET Delay Value.

Ramp 0

DI RH HS-1903C Cont Spray Vlv Ctrl RESET 0

DI RH HS-2001C Cont Spray Valve Ctrl RESET REMOTE FUNCTIONS:

None 295024-06jpm.doc JPM 295024-06 Rev. 5 INSTRUCTOR ACTIONS:

1.

Place the simulator in run and perform the following:

"* Place the MODE switch to SHUTDOWN.

"* Allow drywell pressure to rise to 50 psig. then open four ADS SRV's to depressurize the RPV.

"* When Drywell pressure reaches approximately 70 psig. remove malfunctions AD01D, AD01H and PC13F.

2.

Freeze the simulator.

3.

Note any discrepancies in the comments section for any misperformed steps.

4.

Turn off simulator failure alarm at the instructor station.

5.

Read initial conditions and initiating cues to student.

6.

Place the simulator in run.

TASK STANDARDS:

1.

Fuses RR-F2 and RR-F3 installed.

2.

CV-4301 and CV-4309 closed.

3.

HS 4300A in override.

4.

CV-4300 open.

5.

CV-4357 open.

REQUIRED MATERIALS:

SEP 301.1 SEP 301.3 GENERAL

REFERENCES:

EOP-2 SEP 301.1 SEP 301.3 JPM 295024-06 2 95024-06jpm.doc Rev. 5

Read to the operator the following information:

295024-06jpm.doc JPM 295024-06 Rev. 5 INITIAL CONDITIONS:

1. EOP-2 has been entered on high drywell pressure and temperatures due to SRV-4403, Safety Valve leaking.
2.

"A" RPS Bus has been lost.

3.

HS-1903C (HS-2001C) will not energize to allow spray valve control.

4.

MO-1905, RHR Inboard Inject Valve has a thermal overload.

5.

Torus and drywell pressures are approximately 70 psig and rising.

6.

Emergency Depressurization has been performed based on drywell temperatures and pressures.

INITIATING CUES:

The OSS directs you to Vent the Torus Irrespective of Rad Release per SEP 301.1 for containment pressure control.

This task is NOT time critical.

Inform the evaluator when you have completed the task.

PERFORMANCE INFORMATION Time Start PERFORMANCE STEP:

Verify torus water level is below 16 feet.

Critical:

STANDARD:

Operator verifies torus water level less than 16 feet.

COMMENTS:

PERFORMANCE STEP:

Install Defeats as permitted by the EOPs/SAGs.

Critical:

If venting irrespective of the radioactivity release rate in EOPs/SAGs, install DEFEAT 10, Drywell/Torus Vent and Purge Isolation Defeat. If DEFEAT 10 cannot be installed, exit this procedure and use the Hard Pipe Vent per SEP 301.3.

STANDARD:

Operator determines from the initial conditions that the "A" RPS bus is de-energized and he must exit this procedure and use SEP 301.3.

COMMENTS: If asked about fuel failure; there is no fuel failure If asked if the ERO is manned; the ERO is not manned.

If asked if SEP 301.3 is to be performed; perform SEP 301.3 PERFORMANCE STEP:

Verify torus water level is below 16 feet.

Critical:

STANDARD:

0perator verifies torus water level less than 16 feet.

COMMENTS:

CUE: This was done previously in SEP 301.1 prior to determining that SEP 301.3 was required.

2 95024-06jpm.doc JPM 295024-06 Rev. 5 PERFORMANCE STEP:

Shutdown and isolate the Steam Packing Exhauster as Critical:

follows:

At 1C07, place STEAM PACKING EXHAUSTER BLOWER 1K-6A and B handswitches HS-5205 and HS-6201in the PULL-TO-LOCK position.

STANDARD:

Operator places HS-5205 and HS-6201in the PULL-TO LOCK position.

COMMENTS:

Cue:

PERFORMANCE STEP:

Shutdown and isolate the Steam Packing Exhauster as Critical:

follows:

At 1C07, close MO-1178 and MO-1180, IK-6A[B]

DISCHARGE valves. If power is unavailable, manually close the valves in the Condenser Bay.

STANDARD:

Operator places MO-1178 and MO-1180 to the CLOSE position.

COMMENTS:

Cue:

PERFORMANCE STEP:

Shutdown and isolate the Steam Packing Exhauster as Critical:

follows:

Close V-04-84, STEAM PACKING EXHAUSTER LOOP SEAL ISOLATION. (Condenser Bay, west wall, mezzanine

- 745' level.)

STANDARD:

Operator directs the auxiliary operator (or any inplant operator) to CLOSE V-04-84.

COMMENTS:

Cue:

Contact the operator as the auxiliary operator and inform him that V-04-84 is CLOSED.

295024-06jpm.doc JPM 295024-06 Rev. 5 PERFORMANCE STEP:

Close V-05-97, 1T-15 OUTLET ISOLATION, in the Hogger Critical:

Room.

STANDARD:

An operator is sent to CLOSE V-05-97.

COMMENTS:

Cue:

Instructor acts as Aux Operator/2nd Assistant V-05-97 is closed.

PERFORMANCE STEP:

Install the fuses for CV-4357 as follows:

Critical:

Obtain two 125 VDC fuses from the Hard Pipe Vent Package in the EOP Tool Box.

STANDARD:

Two 125 VDC fuses are obtained from the Hard Pipe Vent Package in the EOP Tool Box.

COMMENTS:

PERFORMANCE STEP:

Install the fuses for CV-4357 as follows:

Critical: C At 1C03 backpanel, install fuses at RR-F2 and RR-F3.

STANDARD:

Operator removes the cage and fuses RR-F2 and RR-F3 are installed.

COMMENTS:

PERFORMANCE STEP:

At 1C03, close the following valves:

Critical:

CV-4301 OUTBD TORUS VENT ISOL CV-4309 INBD TORUS VENT BYPASS ISOL STANDARD:

CV-4301 and CV-4309 closed.

COMMENTS:

JPM 295024-06 Rev. 5 295024-061jpm.doc PERFORMANCE STEP:

Place HS-4300A, CV-4300 HARD PIPE VENT ALT Critical: C PWR/PCIS OVERRIDE, in the OVERRIDE position at 1C32.

STANDARD:

HS-4300A is in OVERRIDE position.

COMMENTS:

PERFORMANCE STEP:

Open the following valves at 1C03 to establish the hard Critical: C pipe vent path:

CV-4300, INBD TORUS VENT ISOL.

CV-4357, HARD PIPE VENT STANDARD:

CV-4300 and CV-4357 are opened.

COMMENTS:

PERFORMANCE STEP:

Monitor containment parameters and confirm actuation of Critical:

rupture disc PSE-4357 on 1C03.

STANDARD:

Operator verifies lowering drywell pressure on PI-4396C or PI-4396D.

JPM 295024-06 Rev. 5 295024-061 pm.doc COMMENTS:

CUE: Pressure may not drop while the candidate is monitoring PI-4396C or PI-4396D.

This is due to the hard pipe vent being sized to remove 10% percent of the decay heat approximately 21 hours2.430556e-4 days <br />0.00583 hours <br />3.472222e-5 weeks <br />7.9905e-6 months <br /> after the shutdown during a station blackout. The leak is much greater than the hard pipe vent capacity and time after shutdown is much less than 21 hours2.430556e-4 days <br />0.00583 hours <br />3.472222e-5 weeks <br />7.9905e-6 months <br />.

Time Stop TERMINATING CUES: Candidate attempts to establish a 45 psig. to 53 psig. pressure band.

JPM 295024-06 295024-06_jpm.doc Rev. 5 PERFORMANCE STEP:

Monitor and control containment venting as follows:

Critical:

If venting for containment pressure control only, vent as necessary to maintain pressure below the Primary Containment Pressure Limit (53 psig). Establish a pressure band for venting between 45 psig and 53 psig, unless otherwise directed by the TSC.

STANDARD:

Operator monitors containment venting and establishes a pressure band 45 psig. to 53 psig.

COMMENTS:

CUE: When the candidate informs you that he will establish a pressure band 45 psig. to 53 psig. the JPM may be terminated.

VERIFICATION OF COMPLETION JPM No.: 295024-06 JPM

Description:

Containment venting irrespective of radioactive release (Alternate Path, Hard Pipe Vent)

Operator:

Evaluator:

Licensee:

[l RO F-1 STA El SRO E-NSPEO Fl SRO Cert Result:

F-SATISFACTORY E-UNSATISFACTORY COMMENTS/FEEDBACK: (Note any trainee discrepancies or misperformed steps.)

Evaluator's Signature 295024-06jpm.doc Date JPM 295024-06 Rev. 5 QF-1030-11 Rev. 1 (FP-T-SAT-30)

S N M C-`b JOB PERFORMANCE MEASURE (JPM)

Commiltted to Nuclear-Excel!

SITE:

TASK TITLE:

JPM NUMBER:

RELATED PRA INFORMATION:

TASK NUMBERS:

K/A NUMBERS:

DAEC PERFORM THE REQUIRED ACTIONS FOR A REPEATED MANUAL SCRAM 212000-10 REV.

1 95.06 K4.07 (4.1/4.1)

A4.01 (4.6/4.6)

SG 15 (4.5/4.7)

A4.14 (3.8/3.8)

APPLICABLE METHOD OF TESTING:

Discussion:

EVALUATION LOCATION:

In-Plant:

Simulator:

Lab:

SRO/RO LIII Simulate/walkthrough:

[--]

L Control Room:

Other:

L---I Perform:

IK]

LIZ Time for Completion:

10 Mir Alternate Path NO Faulted:

TASK APPLICABILITY:

Additional signatures may be added as needed.

iutes Time Critical:

Deveioped b Y Validated by:

Approved by:'

Instructor

"_,ý ý ý Va Wid-ation Instructor (S

JPM Validation Ch mat 1)

Training Supervisor-Operations Retention: Lire or policy + 10yrs.

Retain in: Training Program File Disposition: Reviewer and Approver Page 1 of 15 NO Date Date

ý// Z/O 2ý_

/b#

Date

QF-1030-11 Rev. 1 (FP-T-SAT-30)

Disposition: Reviewer and Approver Rea;in I

uin Tr a in i y

P g Iueyrs.

Retain in: Training Program File Page 2 of 15 D,=+nn+;

I ;.F-iF I;

QF-1030-11 Rev. I (FP-T-SAT-30)

JPM 212000-10, Perform the Required Actions for a Repeated Manual Scram, Rev. 1 JPM Number:

212000-10 JPM

Title:

PERFORM THE REQUIRED ACTIONS FOR A REPEATED MANUAL SCRAM Examinee:

Job

Title:

Start Time Evaluator:

Date:

Finish Time PERFORMANCE RESULTS:

SAT:

UNSAT:

I COMMENTS/FEEDBACK: (Comments shall be made for any steps graded unsatisfactory).

EVALUATOR'S SIGNATURE:

NOTE: Only this page needs to be retained in examinee's record if completed satisfactorily. If unsatisfactory performance is demonstrated, the entire JPM should be retained.

Page 3 of 15

QF-1030-11 Rev. I (FP-T-SAT-30)

JPM 212000-10, Perform the Required Actions for a Repeated Manual Scram, Rev. 1 JPM BRIEFING/TURNOVER I will explain the initial conditions, which step(s) to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this job performance measure will be satisfied.

DURING THE JPM, ENSURE PROPER SAFETY PRECAUTIONS, FME, AND/OR RADIOLOGICAL CONCERNS AS APPLICABLE ARE FOLLOWED.

_INITIAL CONDITIONS:

A manual scram has been attempted but the rods did not fully insert.

V-17-24 has NOT been closed.

INITIATING CUES (IF APPLICABLE):

The OSS directs you to perform the required actions of a repeated manual scram per RIP 102.1 until all control rods are fully inserted.

Page 4 of 15 Add required site specific JPM briefing material here:

i.e., This section is read once for the entire package of JPMs. It is not required to review this section for every JPM being performed in the package. The initial conditions and initiating cue(s)/tasks to be performed should be read and then provided to the examinee.

You may use any approved reference materials normally available including logs. Make all written reports, oral reports, and log entries as if the evolution is actually being performed.

EOP Immediate Actions are required to be performed from memory. After completing immediate action steps without using the procedure, you may then use any approved reference materials.

If this JPM is performed on the simulator, the JPM administrator should only give cues that are not indicated on the simulator. If simulator indication is sufficient to indicate the completion of a step, the JPM administrator should not have to give a cue to the trainee to continue the evolution.

QF-1030-11 Rev. 1 (FP-T-SAT-30)

JPM 212000-10, Perform the Required Actions for a Repeated Manual Scram, Rev. 1 JPM PERFORMANCE INFORMATION Required Materials:

General

References:

Task Standards:

RIP 102.1 EOP-SP Section 100, Rod Insertion Procedures

1. Defeat 3 performed per EOP-SP.
2. Defeat 12 performed IF RPV Level is <119 inches.
3. Operator resets the scram using the REACTOR SCRAM RESET handswitch on 1 C05.
4. Operator re-scrams the reactor using the Manual Scram Pushbuttons on 1C05.

Start Time:

NOTE: When providing "Evaluator Cues" to the examinee, care must be exercised to avoid prompting the examinee. Typically cues are only provided when the examinee's actions warrant receiving the information (i.e. the examinee looks or asks for the indication).

NOTE: Critical steps are marked with a "Y" below the performance step number. Failure to meet the standard for any critical step shall result in failure of this JPM.

Performance Step:

Critical: N Standard:

Page 5 of 15 Perform Defeat 3, RPS Scram Logic Defeat per EOP-SP Section 200.

Candidate inserts Defeat 3 SATISFACTORY UNSATISFACTORY Note: This step is not marked critical but the critical steps of this procedure have been noted as critical if required for support of RIP 102.1.

Performance:

Comments:

QF-1030-11 Rev. I (FP-T-SAT-30)

JPM 212000-10, Perform the Required Actions for a Repeated Manual Scram, Rev. I Start of EOP Defeat 3 Performance Step:

Critical: Y Standard:

Performance:

Comments:

Performance Step:

Critical: Y Standard:

Performance:

Comments:

At Panel 1C15, place RPS CHANNEL Al OVERRIDE keylock switch C71A-S15A to OVERRIDE position and confirm amber light is ON.

C71A-S15A placed in OVERRIDE position.

SATISFACTORY UNSATISFACTORY Note: C71A-S15A-D can be performed in any order but all must be positioned to OVERRIDE.

The amber light should be checked but is not critical for satisfactory completion of the step.

At Panel 1C15, place RPS CHANNEL A2 OVERRIDE keylock switch C71A-S15C to OVERRIDE position and confirm amber light is ON.

C71A-S15C placed in OVERRIDE position.

SATISFACTORY UNSATISFACTORY Note: C71A-S15A - D can be performed in any order but all must be positioned to OVERRIDE.

The amber light should be checked but is not critical for satisfactory completion of the step.

Page 6 of 15

QF-1030-11 Rev. I (FP-T-SAT-30)

JPM 212000-10, Perform the Required Actions for a Repeated Manual Scram, Rev. 1 SPerformance Step:

Critical: Y

- Standard:

Performance:

Comments:

[Performance Step:

Critical: Y Standard:

Performance:

Comments:

At Panel 1C17, place RPS CHANNEL B2 OVERRIDE keylock switch C71A-S15D to OVERRIDE position and confirm amber light is ON C71A-S15D placed in OVERRIDE position.

SATISFACTORY UNSATISFACTORY Note: C71A-Sl5A - D can be performed in any order but all must be positioned to OVERRIDE.

The amber light should be checked but is not critical for satisfactory completion of the step.

Page 7 of 15 Performance Step:

At Panel 1C05, verify that the Al, A2, B1, B2 amber Battleshort lights are ON.

Critical: N Standard:

The Al, A2, B1, B2 amber Battleshort lights are verified to be ON at 1 C05.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

At Panel 1C17, place RPS CHANNEL B1 OVERRIDE keylock switch C71A-S15B to OVERRIDE position and confirm amber light is ON C71A-S15B placed in OVERRIDE position.

SATISFACTORY UNSATISFACTORY Note: C71A-S15A - D can be performed in any order but all must be positioned to OVERRIDE.

The amber light should be checked but is not critical for satisfactory completion of the step.

QF-1 030-11 Rev. I (FP-T-SAT-30)

JPM 212000-10, Perform the Required Actions for a Repeated Manual Scram, Rev. 1 U u ------

Reset the reactor scram using REACTOR SCRAM RESET handswitch C71A-$5 on IC05.

Scram is reset at 1C05.

Performance:

Comments:

End of EOP Defeat 3 Performance Step:

Critical: Y*

Standard:

Performance:

(Comments:

SATISFACTORY UNSATISFACTORY Note: This step is also required in RIP 102.1 this step is satisfied by use of either procedure.

Go back to RIP 102.1 Direct the in-plant operator to install DEFEAT 12 (Reset of ARI).

In-plant operator Is instructed to install Defeat 12.

RPV water level is verified to be >119 inches.

SATISFACTORY UNSATISFACTORY Cue: Simulator Driver: When directed to install Defeat 12 accept the directions and about 2 minutes after you would pick up the defeat package call back and inform the operator Defeat 12 is installed.

Water level verification is NOT critical.

Note: Defeat 12 is usually handed out the back door of the control room and the in-plant operator is instructed to pick it up there. However, he may be called to the Control Room.

  • This may be directed at any time after entry into RIP 102.1 and is not critical if RPV Level remains above 119 inches and all control rods are inserted.

Page 8 of 15 P rerormance Step:

Critical: Y Standard:

Go b ck to RIP 1 2.1

---Idl

QF-1030-11 Rev. I (FP-T-SAT-30)

JPM 212000-10, Perform the Required Actions for a Repeated Manual Scram, Rev. 1 P rerrormance Step: 3 Critical: Y Standard:

Performance:

Comments:

Reset the Reactor Scram.

Operator resets the scram using the REACTOR SCRAM RESET handswitch on 1C05.

SATISFACTORY UNSATISFACTORY Note: This may have been performed in the last step of Defeat 3.

Performance Step: 4 Confirm that annunciator (IC05B, C-1) SCRAM DISCHARGE VOLUME HI Critical: N LEVEL TRIP, is reset.

Standard:

Operator verifies Scram Discharge Volume Hi Level Trip is reset.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

! Performance Step: 5 Assess rod positions using any of the following methods:

Critical: N e

3D Monicore Program RODLOG 9

SPDS Computer Display DR 9

Full Core Display Standard:

Operator assesses rod positions by using either of the following: 3D Monicore Program RODLOG, SPDS Computer Display DR, or the Full Core Display.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

Page 9 of 15

\\

QF-1030-11 Rev. I (FP-T-SAT-30)

JPM 212000-10, Perform the Required Actions for a Repeated Manual Scram, Rev. 1 I Performance Step: 6 Critical: Y If reactor pressure is greater than 600 psig (the minimum reactor pressure needed to scram control rods without CRD hydraulic assistance), perform the following:

Performance:

Comments:

iPerrormance Step: 6 b)

Critical: N Standard:

Re-scram using the Manual Scram Pushbuttons on 1C05 Depress both Manual Scram Pushbuttons on 1005.

SATISFACTORY UNSATISFACTORY If closed, OPEN charging water header throttle valve V-17-24 (RB 757',

CRD Flow Control Station Area) and verify that HCU accumulators are charged.

Verify V-1 7-24 is open.

Performance:

'Comments:

Performance Step: 7 Critical: N a) b)

Standard:

Performance:

Comments:

SATISFACTORY UNSATISFACTORY V-1 7-24 is NOT closed per the turnover and this step may be marked N/A or skipped.

Cue: If asked whether V-17-24 is open or closed reply that V-17-24 is open.

If reactor pressure is less than 600 psig, perform the following:

If closed, OPEN charging water header throttle valve V-17-24 (RB 757',

CRD Flow Control Station Area) and verify that HCU accumulators are charged.

Re-scram using the Manual Scram Pushbuttons on 1C05.

RPV pressure is greater than 600 psig and these steps may be marked N/A or skipped.

SATISFACTORY UNSATISFACTORY Page 10 of 15 a)

Standard:

SB

QF-1030-11 Rev. I (FP-T-SAT-30)

JPM 212000-10, Perform the Required Actions for a Repeated Manual Scram, Rev. 1 I Performance Step: 8 Critical: N I/

Standard:

Check for indications of control rod movement using any of the following methods:

"* 3D Monicore Program RODLOG

"* SPDS Computer Display DR

"* Full Core Display Operator assesses rod positions by using either of the following: 3D Monicore Program RODLOG, SPDS Computer Display DR, or the Full Core Display.

Performance:

Comments:

SATISFACTORY UNSATISFACTORY Performance Step: 9 Repeat Steps (3) - (8) as directed by the OSS until all control rods are Performance Step: 9 Critical: Y Standard:

Repeat Steps (3) - (8) as directed by the OSS until all control rods are inserted to or beyond position 02.

Steps 3 - 8 are repeated until all rods are fully inserted.

Performance:

Comments:

SATISFACTORY UNSATISFACTORY Booth Instructor:

On the 3r reset of the scram remove the malfunction for the hydraulic ATWS and allow the rods to scram.

Delete Malfunction: rpO5f Terminating Cues:

All rods have been verified full in.

Stop Time:

Page 11 of 15

QF-1030-11 Rev. I (FP-T-SAT-30)

JPM 212000-10, Perform the Required Actions for a Repeated Manual Scram, Rev. 1 SIMULATOR SET UP:

"= Reset to any Full power IC.

"* Verify malfunction rpO5f HYDRAULIC LOCK SCRAM DISCHARGE VOLUME is active

"* Depress the SCRAM pushbuttons on 1C05.

SIMULATOR EVENT TRIGGERS:

None SIMULATOR MALFUNCTIONS:

Time Malf No.

Malfunction Title ET Delay F. Sev. Ramp I. Sev.

00:00 rp05f HYDRAULIC LOCK As N/A N/A N/A N/A SCRAM DISCHARGE Needed VOLUME

\\--'SIMULATOR OVERRIDES:

None SIMULATOR REMOTE FUNCTIONS:

None Page 12 of 15

QF-1030-11 Rev. I (FP-T-SAT-30)

JPM 212000-10, Perform the Required Actions for a Repeated Manual Scram, Rev. 1 TURNOVER SHEET I

INITIAL CONDITIONS:

A manual scram has been attempted but the rods did not fully insert.

V-17-24 has NOT been closed.

INITIATING CUES (IF APPLICABLE):

  • The OSS directs you to perform the required actions of a repeated manual scram per RIP 102.1 until all control rods are fully inserted.

Page 13 of 15

QF-1030-11 Rev. I (FP-T-SAT-30)

JPM 212000-10, Perform the Required Actions for a Repeated Manual Scram, Rev. 1 ATTACHMENT I JOB PERFORMANCE MEASURE VALIDATION CHECKLIST ALL STEPS IN THIS CHECKLIST ARE TO BE PERFORMED UPON INITIAL VALIDATION AND PRIOR TO USE.

REVIEW STATEMENTS YES NO N/A

1.

Are all items on the signature page filled in correctly?

1:1

[]

[]

2.

Has the JPM been reviewed and validated by SMEs?

E]

Li L

3.

Can the required conditions for the JPM be appropriately

[T 0i n

established in the simulator if required?

4.

Does the performance steps accurately reflect trainee's actions in Ei Li accordance with plant procedures?

5.

Is the standard for each performance item specific as to what i

i controls, indications and ranges are required to evaluate if the trainee properly performed the step?

6.

Has the completion time been established based on validation data E

Li

[l or incumbent experience?

7.

If the task is time critical, is the time critical portion based upon El Li Li actual task performance requirements?

8.

Is the Licensee level appropriate for the task being evaluated if

[

Li Li required?

9.

Is the K/A appropriate to the task and to the licensee level if EL" L i required?

./10.

Have the performance steps been identified and typed (Critical/ I Li Li Sequence / Time Critical) appropriately?

11.

Have all special tools and equipment needed to perform the task E

Li Li been identified and made available to the trainee?

12.

Are all references identified, current, accurate, and available to the Li Ll il trainee?

13.

Have all required cues (as anticipated) been identified for the E Li Li evaluator to assist task completion?

All questions/statements must be answered "YES" or the JPM is not valid for use. If all questions/statements are answered "YES" then the JPM is considered valid and can be performed as written. The individual(s) performing the validation shall sign and date this form.

Validation Personnel /

7D6te Validation Personnel /Date Validation Personnel /Date Validation Personnel/Date Validation Personnel/Date Validation Personnel/Date Page 14 of 15

QF-1030-11 Rev. 1 (FP-T-SAT-30)

JPM 212000-10, Perform the Required Actions for a Repeated Manual Scram, Rev. I Validation Personnel /Date Validation Personnel/Date Page 15 of 15

QF-1 030-11 Rev. 1 (FP-T-SAT-30)

NMC C~o,,rtted to Nuclear Excei-ienoe SITE:

TASK TITLE:

JPM NUMBER:

RELATED PRA INFORMATION:

TASK NUMBERS:

K/A NUMBERS:

JOB PERFORMANCE MEASURE (JPM)

DAEC PRA FOR HPCI RAPID START FOR LEVEL CONTROL (FAULTED) 206000-15 REV.

3 5.05 K1.14 (2.9/3.1)

SG-9 (3.9/3.7)

K4.05 (3.313.3)

A4.04 (3.7/3.7)

K4.08 (4.2/4.3)

K4.18 (3.2/3.3)

A1.01 (4.3/4.3)

EK2.06 (4.114.2)

K4.11 (3.4/3.5)

K5.03 (3.113.1)

A4.02 (4.0/3.8)

K4.03 (4.214.1)

.47

/

APPLICABLE METHOD OF TESTING:

EVALUATION LOCATION:

Discussion:

In-Plant:

Simulator:

L-I Simulate/walkthrough:

[

SI Control Room:

7 Other:

Perform:

[-]

I---

Time for Completion:

5 Minutes Time Critical:

Alternate Path /

Faulted:

YES TASK APPLICABILITY:________________________

Additional signatures may be added as needed.

4.-

II I;LI UL*tUI I



Retaen on: Life On Policy + 1 Fyrs.

Retain in: Training Program File Date I Disposition: Reviewer and Approver Page 1 of 13 SRO/RO NO I

I I

-I Deeoedb 7/t Ho Z_ -

QF-1030-11 Rev. I (FP-T-SAT-30)

Pafanlirn -

I ;L,,-,

I~J

.LECLEj~I~

r-*;,

L U)'....

RetainWM In: Trin i y -r IlOra.

Retain in: Training Program File Disposition: Reviewer and Approver Page 2 of 13

QF-1 030-11 Rev. I (FP-T-SAT-30)

JPM 206000-15, PRA for HPCI Rapid Start for Level Control (faulted), Rev. 3

_J JPM Number:

JPM

Title:

Examinee:

Job

Title:

Start Time 206000-15 PRA FOR HPCI RAPID START FOR LEVEL CONTROL (FAULTED)

Evaluator:

Date:

Finish Time PERFORMANCE RESULTS:

SAT: I I UNSAT:

COMMENTSIFEEDBACK: (Comments shall be made for any steps graded unsatisfactory).

I

/

EVALUATOR'S SIGNATURE:

NOTE: Only this page needs to be retained in examinee's record if completed satisfactorily. If unsatisfactory performance is demonstrated, the entire JPM should be retained.

Page 3 of 13

QF-1030-11 Rev. I (FP-T-SAT-30)

JPM 206000-15, PRA for HPCI Rapid Start for Level Control (faulted), Rev. 3 I will explain the initial conditions, which step(s) to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this job performance measure will be satisfied.

DURING THE JPM, ENSURE PROPER SAFETY PRECAUTIONS, FME, AND/OR RADIOLOGICAL CONCERNS AS APPLICABLE ARE FOLLOWED.

NOTE: Check the simulator setup and give the appropriate INITIAL CONDITION INITIAL CONDITIONS:

While operating at power, there has been a complete loss of feedwater.

Water level is at approximately 150 inches and dropping slowly.

INITIATING CUES:

The OSS has directed a second operator to establish RHR in torus cooling.

Per EOP-1, the OSS directs you to RAPIDLY start HPCI and inject into the reactor at greater than 3000 gpm to raise RPV level using 01152 QRC 1.

Page 4 of 13 JPM BRIEFING/TURNOVER Add required site specific JPM briefing material here:

i. e., This section is read once for the entire package of JPMs. It is not required to review this section for every JPM being performed in the package. The initial conditions and initiating cue(s)/tasks to be performed should be read and then provided to the examinee.

You may use any approved reference materials normally available including logs. Make all written reports, oral reports, and log entries as if the evolution is actually being performed.

EOP Immediate Actions are required to be performed from memory. After completing immediate action steps without using the procedure, you may then use any approved reference materials.

If this JPM is performed on the simulator, the JPM administrator should only give cues that are not indicated on the simulator. If simulator indication is sufficient to indicate the completion of a step, the JPM administrator should not have to give a cue to the trainee to continue the evolution.

ALTERNATE INITIAL CONDITIONS IF THE SIMULATOR SETUP IS DIFFERENT:

"* For the purpose of this task, actual simulator conditions may not actually be modeled. You are responsible for HPCI operation only.

"* While operating at power, there has been a complete loss of feedwater.

"* Water level is at approximately 150 inches and dropping slowly.

QF-1030-11 Rev. I (FP-T-SAT-30)

JPM 206000-15, PRA for HPCI Rapid Start for Level Control (faulted), Rev. 3

/

.JPM PERFORMANCE INFORMATION Required Materials:

General

References:

Task Standards:

01 152, QRC 1 and Section 10.1 01152

1.
2.
3.
4.

5.

Lube Oil and Condenser Cooling Valve, HS-2247 placed in OPEN.

Main Steam Supply MO-2202, HS-2202 placed in OPEN.

Auxiliary Oil Pump, HS-2256 placed in START Inject Valve MO-2312, HS-2312 placed in OPEN.

Flow controller shifted to MANUAL with turbine speed >2000 RPM and flow

> 3000 gpm Start Time:

Page 5 of 13 Performance Step:

If HPCI previously tripped on RPV High Water Level, depress HS-2299, RX HI Critical: N WATER LEVEL HPCI TURBINE TRIP reset switch.

Standard:

RPV level has not caused the High Level trip but the operator may depress HS 2299 and this would be allowed but not required.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

QF-1030-11 Rev. I (FP-T-SAT-30)

JPM 206000-15, PRA for HPCI Rapid Start for Level Control (faulted), Rev. 3 "Performance Step:

Open MO-2247, HPCI Lube Oil Cooler Supply Valve.

/Critical: Y Standard:

Places HS-2247 in open.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

Performance Step:

Start IP-233, HPCI VACUUM PUMP.

Critical: N Standard:

Places HS-2221 in start.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

Performance Step:

Open MO-2202, HPCI Turbine Steam Supply Valve.

Critical: Y Standard:

Places HS-2202 in open.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

Performance Step:

Start IP-218, HPCI Aux Oil Pump.

Critical: Y Standard:

Places HS-2256 for IP-218 in start.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

-I Page 6 of 13

QF-1030-11 Rev. I (FP-T-SAT-30)

JPM 206000-15, PRA for HPCI Rapid Start for Level Control (faulted), Rev. 3 Performance Step:

Critical: Y Standard:

Performance:

Comments:

For RPV injection, immediately open MO-2312, HPCI Inject Valve.

Places HS-2312 to open.

SATISFACTORY UNSATISFACTORY NOTE: At this point the operator will have to recognize the failure of the flow controller in AUTOMATIC. He may attempt to adjust the tape to control flow but it will not work. Manual control should be attempted next.

If the operator request permission to shift the HPCI Flow Controller to Manual the OSS should give him permission to shift HPCI Flow control to manual.

01152 section 10.1 "HPCI this JPM.

Flow Controller Transfer from Automatic to Manual" is the alternate path for NOTE: One option the operator could possibly perform is to use the Test Pot and inject. If the operator chooses to use the Test Pot the alternate path section can be marked satisfactory IF RPV level is increasing due to HPCI injection or HPCI is injecting at >3000 gpm injecting into the vessel.

Page 7 of 13 Oerformance Step:

Verify MO-2311, HPCI Pump Discharge Valve, open

- ritical: N Standard:

Observes MO-2311 OPEN.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

QF-1030-11 Rev. I (FP-T-SAT-30)

JPM 206000-15, PRA for HPCI Rapid Start for Level Control (faulted), Rev. 3 Perrormance Step:

"Critical: N Standard:

Performance:

Comments:

Verify FIC 2309 FLOW CONTROL controller Auto/Manual transfer switch in the AUTO position.

FIC 2309 FLOW CONTROL controller Auto/Manual transfer switch in the AUTO position is verified.

SATISFACTORY UNSATISFACTORY This step may be skipped or marked N/A because the operator knows the controller position already.

Performance Step:

Critical: N Standard:

Place FIC-2309 FLOW CONTROL controller Auto/Manual transfer switch in the Place FIC-2309 FLOW CONTROL controller Auto/Manual transfer switch in the BAL position.

Places FIC-2309 to BAL position (indicator pointing toward the BAL position).

Performance:

Comments:

Performance:

Comments:

SATISFACTORY UNSATISFACTORY This step may be skipped or marked N/A because the operator does not have to balance the controller due to the failure of the automatic function.

Adjust the Manual Adjust Knob such that the red pointer of the deviation meter matches (lines up) with the setpoint.

Adjusts the Manual Output Adjust Knob (knurl knob) to align the deviation meter with the setpoint.

SATISFACTORY UNSATISFACTORY This step may be skipped or marked N/A because the operator does not have to balance the controller due to the failure of the automatic function.

Page 8 of 13 Performance Step:

Critical: N Standard:

QF-1 030-11 Rev. I (FP-T-SAT-30)

JPM 206000-15, PRA for HPCI Rapid Start for Level Control (faulted), Rev. 3 0 erformance Step:

KCritical: Y Standard:

Performance:

Comments:

Place FIC-2309 FLOW CONTROL controller Auto/Manual transfer switch in the MANUAL position. Adjust FIC-2309 Manual Adjust Knob to control HPCI Turbine speed to attain the desired HPCI pump flow.

Places FIC-2309 to MANUAL and adjusts the Manual Adjust Knob (knurl knob) to obtain greater than 3000 gpm flow rate and HPCI turbine speed greater than 2000 rpm.

SATISFACTORY UNSATISFACTORY The operator may go directly to this step and start controlling level due to familiarity with this feature of the HPCI Controller.

Terminating Cues:

When HPCI injection has been established at > 3000 gpm injecting into the RPV.

Stop Time:

Page 9 of 13

QF-1030-11 Rev. I (FP-T-SAT-30)

JPM 206000-15, PRA for HPCI Rapid Start for Level Control (faulted), Rev. 3

\\,,S31MULATOR SET UP:

0 Any at-power IC.

EVENT TRIGGERS:

Time Malfunction No.

Malfunction Title ET Delay F. Sev. Ramp I. Sc Setup hp03 HPCI Flow 0

0 0

As Controller failure SIMULATOR MALFUNCTIONS:

None SIMULATOR OVERRIDES:

None SIMULATOR REMOTE FUNCTIONS:

None Page 10 of 13 I

QF-1030-11 Rev. 1 (FP-T-SAT-30)

TURNOVER SHEET

'\\ldNITIAL CONDITIONS:

While operating at power, there has been a complete loss of feedwater.

Water level is at approximately 150 inches and dropping slowly.

INITIATING CUES (IF APPLICABLE):

The OSS has directed a second operator to establish RHR in torus cooling.

Per EOP-1, the OSS directs you to RAPIDLY start HPCI and inject into the reactor at greater than 3000 gpm to raise RPV level using 01 152 QRC 1.

Page 11 of 13 ALTERNATE INITIAL CONDITIONS IF THE SIMULATOR SETUP IS DIFFERENT:

For the purpose of this task, actual simulator conditions may not actually be modeled. You are responsible for HPCI operation only.

While operating at power, there has been a complete loss of feedwater.

Water level is at approximately 150 inches and dropping slowly.

QF-1030-11 Rev. I (FP-T-SAT-30)

JPM 206000-15, PRA for HPCI Rapid Start for Level Control (faulted), Rev. 3 ATTACHMENT I JOB PERFORMANCE MEASURE VALIDATION CHECKLIST ALL STEPS IN THIS CHECKLIST ARE TO BE PERFORMED UPON INITIAL VALIDATION AND PRIOR TO USE.

REVIEW STATEMENTS YES NO N/A

1.

Are all items on the signature page filled in correctly?

1 D

LI

2.

Has the JPM been reviewed and validated by SMEs?

LI LI

3.

Can the required conditions for the JPM be appropriately I

LI L]

established in the simulator if required?

4.

Does the performance steps accurately reflect trainee's actions in I

I accordance with plant procedures?

5.

Is the standard for each performance item specific as to what LI L]

controls, indications and ranges are required to evaluate if the trainee properly performed the step?

6.

Has the completion time been established based on validation data 7

LI

[]

or incumbent experience?

7.

If the task is time critical, is the time critical portion based upon I

LI I

actual task performance requirements?

8.

Is the Licensee level appropriate for the task being evaluated if LI LI required?

9.

Is the K/A appropriate to the task and to the licensee level if 7

LI LI required?

10.

Have the performance steps been identified and typed (Critical /

LI LI Sequence / Time Critical) appropriately?

11.

Have all special tools and equipment needed to perform the task LI EI been identified and made available to the trainee?

12.

Are all references identified, current, accurate, and available to the E

LI L]

trainee?

13.

Have all required cues (as anticipated) been identified for the 19" EL 0

evaluator to assist task completion?

All questions/statements must be answered "YES" or the JPM is not valid for use. If all questions/statements are answered "YES" then the JPM is considered valid and can be performed as written. The individual(s) performing the validation shall sign and date this form.

449ke?-

C11 t/-

Validation Personnel /tafe Validation Personnel /Date Validation Personnel /Date Validation Personnel/Date Validation Personnel/Date Validation Personnel/Date Page 12 of 13

QF-1 030-11 Rev. I (FP-T-SAT-30)

JPM 206000-15, PRA for HPCI Rapid Start for Level Control (faulted), Rev. 3

"\\,.,4alidation Personnel /Date Validation Personnel/Date Page 13 of 13

QF-1030-11 Rev. 1 (FP-T-SAT-30)

NMC JOB PERFORMANCE MEASURE (JPM)

Committed to Nuclear ffx6D11e~

5

'-"J SITE:

TASK TITLE:

JPM NUMBER:

RELATED PRA INFORMATION:

TASK NUMBERS:

K/A NUMBERS:

DAEC SBDG STP 3.8.1-04 SBDG Slow start operability SID /Phase Overcurrent or Ground Fault Alarm/ Rapid SBDG SID. (Alternate Path) 264000-XX REV.

0 RO 19.06 264000 A4.04 Importance RO 3.71 SRO 3.7 APPLICABLE METHOD OF TESTING:

Discussion:

EVALUATION LOCATION:

In-Plant:

Simulator:

L Simulate/walkthrough:

LI]

Control Room:

Other:

Perform:

[-]

Time for Completion:

Alternate Path /

Faulted:

TASK APPLICABILITY:

10 Minutes Time Critical:

AP SROIRO Retention: Lite ot policy + 1 Oyrs.

Retain in: Training Program File Disposition: Reviewer and Approver Page 1 of 10 NO

QF-1030-11 Rev. I (FP-T-SAT-30)

JPM 264000-xx, SBDG STP 3.8.1-04 SBDG Slow Start Operability S/D /Phase Overcurrent or Ground Fault Alarm/ Rapid SBDG S/D. (Alternate Path), Rev. 0 JPM Number:

264000 JPM

Title:

Examinee:

Job

Title:

Start Time SBDG STP 3.8.1-04 SBDG Slow start operability S/D /Phase Overcurrent or Ground Fault Alarm/ Rapid SBDG S/D. (Alternate Path)

Evaluator:

Date:

Finish Time PERFORMANCE RESULTS:

SAT:ZIZ UNSAT:ZIZ COMMENTS/FEEDBACK: (Comments shall be made for any steps graded unsatisfactory).

EVALUATOR'S SIGNATURE:

NOTE: Only this page needs to be retained in examinee's record if completed satisfactorily. If unsatisfactory performance is demonstrated, the entire JPM should be retained.

Page 2 of 10

QF-1030-11 Rev. I (FP-T-SAT-30)

JPM 264000-xx, SBDG STP 3.8.1-04 SBDG Slow Start Operability S/D /Phase Overcurrent or Ground Fault Alarm/ Rapid SBDG S/D. (Alternate Path), Rev. 0 I will explain the initial conditions, which step(s) to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this job performance measure will be satisfied.

DURING THE JPM, ENSURE PROPER SAFETY PRECAUTIONS, FME, AND/OR RADIOLOGICAL CONCERNS AS APPLICABLE ARE FOLLOWED.

INITIAL CONDITIONS:

STP 3.8.1-04 "SBDG Operability Test (Slow Start From Normal Start Air)" is in progress.

1G-31 "A SBDG" has been loaded for two hours at rated load.

The "A" SBDG Operating Checklist has been completed and all conditions were satisfactory.

Assume all STP sections performed to this point are satisfactory and appropriately completed.

INITIATING CUES (IF APPLICABLE):

The OSS directs you to continue with STP 3.8.1-04 at step 7.1.27.

Page 3 of 10 JPM BRIEFING/TURNOVER Add required site specific JPM briefing material here:

i.e., This section is read once for the entire package of JPMs. It is not required to review this section for every JPM being performed in the package. The initial conditions and initiating cue(s)/tasks to be performed should be read and then provided to the examinee.

You may use any approved reference materials normally available including logs. Make all written reports, oral reports, and log entries as if the evolution is actually being performed.

EOP Immediate Actions are required to be performed from memory. After completing immediate action steps without using the procedure, you may then use any approved reference materials.

If this JPM is performed on the simulator, the JPM administrator should only give cues that are not indicated on the simulator. If simulator indication is sufficient to indicate the completion of a step, the JPM administrator should not have to give a cue to the trainee to continue the evolution.

QF-1030-11 Rev. 1 (FP-T-SAT-30)

JPM 264000-xx, SBDG STP 3.8.1-04 SBDG Slow Start Operability S/D /Phase Overcurrent or Ground Fault Alarm/ Rapid SBDG S/D. (Alternate Path), Rev. 0 JPM PERFORMANCE INFORMATION Required Materials:

General

References:

Task Standards:

STP 3.8.1-04 accurately completed up to Step 7.1.27 (Reducing SBDG from full load to 1500KW) 01 324 "SBDG" STP 3.8.1-04 IC08A B-1I "A Diesel Gen. IG-31 Phase Overcurrent or Ground Fault" Start Time:

NOTE: Critical steps are marked with a "Y" be.o.th. pe nce step number. Filre tomeet th standard for any' critical step shaII result in failure of this JPM.

Performance Step:

KCritical: N Standard:

Performance:

Comments:

At 1C08, using speed and voltage adjust, lower generator load to approximately 1500KW at 260 amps and hold for 10 minutes.

"A" SBDG load is reduced to z 1500 KW at z 260 amps using speed and voltage adjust.

SATISFACTORY UNSATISFACTORY If the Operator is taking too long to reduce load, the JPM can continue by inserting the 1 C08A B-1 1 annunciator. The ARP will require load reduction.

Page 4 of 10 I

QF-1030-11 Rev. 1 (FP-T-SAT-30)

JPM 264000-xx, SBDG STP 3.8.1-04 SBDG Slow Start Operability S/D /Phase Overcurrent or Ground Fault Alarm/ Rapid SBDG S/D. (Alternate Path), Rev. 0

'Performance Step:

Critical: N Standard:

Performance:

Comments:

Performance Step:

Critical: Y Standard:

Performance:

Comments:

Place handswitch BUS 1A3 Transfer in MANUAL Place handswitch BUS 1A3 Transfer in MANUAL SATISFACTORY UNSATISFACTORY Cue: When the OSS is asked if he wants to shutdown the "A' SBDG reply "YES, secure the Alpha Standby Diesel Generator".

Performance Step:

Reduce the load on the Diesel Generator to 50 KW by using the DIESEL Performance Step:

Critical: N Standard:

Performance:

Comments:

Reduce the load on the Diesel Generator to 50 KW by using the DIESEL GENERATOR 1G-31 SPEED ADJUST CONTROL.

"A" SBDG load is reduced to approximately 50 KW using speed adjust.

SATISFACTORY UNSATISFACTORY Page 5 of 10 Review ARP actions Pull ARP and review required actions SATISFACTORY UNSATISFACTORY Simulator Driver: About 1 minute after the "A" SBDG is at 1500 KW (or as directed by the Floor Instructor) 1C08A B-1I alarms.

Insert annunciator AN 1C08(23) IC08A(B-11) ANNUNCIATOR BOX (4HX12W): Set Malfunction Value to 3-ON; Delay Time 00:00:00.

Cue: If asked if ARP should be performed - tell the operator to perform the ARP actions.

QF-1030-11 Rev. 1 (FP-T-SAT-30)

JPM 264000-xx, SBDG STP 3.8.1-04 SBDG Slow Start Operability S/D /Phase Overcurrent or Ground Fault Alarm/ Rapid SBDG S/D. (Alternate Path), Rev. 0 Performance Step:

Critical: Y Standard:

Performance:

Comments:

Performance Step:

Critical: Y Standard:

Performance:

Place the control switch for 4KV BREAKER 1A311A DIESEL GENERATOR 1G 31 in the TRIP position. Observe that the green (breaker tripped) and the white (closing spring charged) indicating lights are ON.

The control switch for 4KV BREAKER 1A311A DIESEL GENERATOR 1G-31 is taken to the TRIP position. Verify breaker is OPEN by the green and white indicating lights are on.

SATISFACTORY UNSATISFACTORY Verifying the green and white lights are on is NOT critical for satisfactory completion of this step.

Place the BUS 1A3 TRANFER breaker mode selector switch in the AUTO position.

BUS 1A3 TRANFER breaker mode selector switch is returned to the AUTO position.

SATISFACTORY UNSATISFACTORY Comments:

Page 6 of 10 Performance Step:

At 1C08, confirm annunciator 4KV BUS AUTO TRANSFER INOP (1 C08A, D-7) is Critical: N reset.

Standard:

Confirm annunciator 4KV BUS AUTO TRANSFER INOP (1C08A, D-7) is reset.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

QF-1030-11 Rev. I (FP-T-SAT-30)

JPM 264000-xx, SBDG STP 3.8.1-04 SBDG Slow Start Operability SID /Phase Overcurrent or Ground Fault Alarm/ Rapid SBDG S/D. (Alternate Path), Rev. 0 Oerformance Step:

-tritical: Y Standard:

Performance:

Comments:

Stop A DIESEL GENERATOR 1G-31 by placing A DIESEL GENERATOR 1G-31 Control handswitch HS-3231A on Panel 1 C08 in the STOP position, hold for 5 to 10 sec., and then place the control switch in the Pull to Lock position.

Control handswitch HS-3231A on Panel 1 C08 is held in the STOP position for 5 to 10 sec., and then placed in the Pull to Lock position.

SATISFACTORY UNSATISFACTORY If informed that this will make the SBDG inop acknowledge the "A" SBDG will be/is inop.

If the hand switch is not held in stop for 5 to 10 seconds and the SBDG automatically restarts after the "Shutdown Relay" clears (about 1 minute after switch is taken to Pull to Lock) this step would be marked unsatisfactory.

Otherwise the step is marked satisfactory if the handswitch is in Pull to Lock at the completion of this step.

Performance Step:

Identify the relay that caused the alarm Critical: N Standard:

Request the Auxiliary Operator determine the which relay caused the alarm Performance:

SATISFACTORY UNSATISFACTORY Comments:

Cue: Aux operator reports the Ground Fault relay is the cause of the alarm.

Performance Step:

Inspect the "A" SBDG 1 G-31 for visible damage and/or overheating.

Critical: N Standard:

Direct the Aux Operator to inspect the "A" SBDG for visible signs of damage and overheating..

Performance:

SATISFACTORY UNSATISFACTORY Comments:

Cue: Aux Operator reports there is no apparent damage the "A" SBDG Terminating Cues:

When ARP Operator Actions are complete, direct the operator to suspend the STP and the JPM is complete.

,Stop Time:

Page 7 of 10

QF-1030-11 Rev. I (FP-T-SAT-30)

JPM 264000-xx, SBDG STP 3.8.1-04 SBDG Slow Start Operability S/D /Phase Overcurrent or Ground Fault Alarm/ Rapid SBDG S/D. (Alternate Path), Rev. 0 SIMULATOR SET UP:

This JPM can be run from any IC that supports "A" SBDG STP 3.8.1-04 Slow Start.

Start "A" SBDG in parallel and load to 2850 KW SIMULATOR EVANT TRIGGERS:

ET I dgwatt(l).Ile. 2.2E6 SIMULATOR MALFUNCTIONS:

None SIMULATOR OVERRIDES:

Following the first step and after load reduction or as directed by the Floor Instructor.

Insert annunciator AN 1C08A(23) IC08A(B-11) ANNUNCIATOR BOX (4HX12W): on ET I Set Malfunction Value to: 3-ON Delay Time:

00:00:00 INSERT SIMULATOR REMOTE FUNCTIONS:

None Page 8 of 10

QF-1030-11 Rev. I (FP-T-SAT-30)

JPM 264000-xx, SBDG STP 3.8.1-04 SBDG Slow Start Operability S/D /Phase Overcurrent or Ground Fault Alarm/ Rapid SBDG S/D. (Alternate Path), Rev. 0 TURNOVER SHEET INITIAL CONDITIONS:

STP 3.8.1-04 is in progress.

1G-31 "A SBDG" has been loaded for two hours at rated load.

The "A" SBDG Operating Checklist has been completed and all conditions were satisfactory.

0 Assume all sections performed to this point a satisfactory and appropriately completed.

INITIATING CUES:

0 The OSS directs you to continue with STP 3.8.1-04 at step 7.1.27.

Page 9 of 10

QF-1030-11 Rev. I (FP-T-SAT-30)

`K>_

JPM 264000-xx, SBDG STP 3.8.1-04 SBDG Slow Start Operability S/D /Phase Overcurrent or Ground Fault Alarm/ Rapid SBDG S/D. (Alternate Path), Rev. 0 ATTACHMENT I JOB PERFORMANCE MEASURE VALIDATION CHECKLIST ALL STEPS IN THIS CHECKLIST ARE TO BE PERFORMED UPON INITIAL VALIDATION AND PRIOR TO USE.

REVIEW STATEMENTS YES NO N/A

1.

Are all items on the signature page filled in correctly?

f Fl1 El

2.

Has the JPM been reviewed and validated by SMEs?

Lii LF

3.

Can the required conditions for the JPM be appropriately ED,'

E]

established in the simulator if required?

4.

Does the performance steps accurately reflect trainee's actions in il Rl El accordance with plant procedures?

5.

Is the standard for each performance item specific as to what 1*

Eli LI controls, indications and ranges are required to evaluate if the trainee properly performed the step?

6.

Has the completion time been established based on validation data E"

EI EL or incumbent experience?

7.

If the task is time critical, is the time critical portion based upon

[V EL lI actual task performance requirements?

8.

Is the Licensee level appropriate for the task being evaluated if fL El I:

required?

9.

Is the K/A appropriate to the task and to the licensee level if B"

E]

El required?

10.

Have the performance steps been identified and typed (Critical W

E]

L-El Sequence / Time Critical) appropriately?

11.

Have all special tools and equipment needed to perform the task EL En been identified and made available to the trainee?

12.

Are all references identified, current, accurate, and available to the

[V El El trainee?

13.

Have all required cues (as anticipated) been identified for the E9 El El evaluator to assist task completion?

All questions/statements must be answered "YES" or the JPM is not valid for use. If all questions/statements are answered "YES" then the JPM is considered valid and can be performed as written. The individual(s) performing the validation shall sign and date this form.

Validation Personnel /Date Validation Personnel /Date Validation Personnel/Date Validation Personnel/Date Validation Personnel/Date Page 10 of 10 Validation Personnel /Date

D UANE ARNOLD ENERGY CENTER JOB PERFORMANCE MEASURE NUMBER 263000-01 Task Number: NSPEO 29.01 TITLE: SHIFT 250 VDC BATTERY CHARGERS

/31 2,

6 Rev. 0 07/31/96 Preparer/Date -s..

Pages DEVELOPED BY:,

D Instructor Date VALIDATED BY:

REVIEWED BY:

APPROVED BY:

IE/Instructor Plant Reviewer Training Supervisor-Operations Date Date Date I &I # __J.

IMA;;;-

,rc Lagrer/Dates idages (

FF&I #

TMAR#

Preparer/Date Pages 7

DUANE ARNOLD ENERGY CENTER JOB PERFORMANCE MEASURE JPM 263000-01 Rev. 0 07/31/96 26300001.JPM JPM No. 263000-01 JPM

Description:

Shift 250 VDC Battery Chargers Task No.

Task

Description:

Remove from/place in service (shift) battery NSPEO 29.01 chargers (125 VDC and 250 VDC)

K/A

Reference:

K1.02 (3.2/3.3) 263000 System Generic #9 (3.4/3.5)

APPLICABLE METHOD OF TESTING:

Simulate Performance.

X I Actual Performance Simulator In-Plant X

Control Room Time for Completion: 15 Minutes t

JOB PERFORMANCE MEASURE VALIDATION CHECKLIST NOTE All steps of this checklist should be performed upon initial validation. Prior to JPM usage, revalidate JPM using steps 7 through 10.

JPM #: 263000-01 JPM

Description:

Shift 250 VDC Battery Chargers

1.

Task description and number, JPM description and number are identified

2.

Task elements identified and K/A references are included

3.

Performance location specified

a.

in-plant

b.

control room

c.

simulator

4.

Initial conditions and cues identified

a.

setup, required materials, and procedure

b.

malfunctions and instructor actions

c.

initiating and terminating cues

5.

Task standards identified and verified by SME review

6.

Critical tasks/steps identified meet criteria and identified with a "C"

7.

Verify JPM steps fit the most current procedures Procedure Rev. 1 Date 1-]7]ci"

8.

Pilot test JPM ¢ I

a.

verify cues boq verbal and visual are free of conflict

b.

ensure performance time is accurate

9.

If the JPM cannot be performed as written with proper responses, then revise the JPM

10. When JPM is revalidated, SME/Instructor signs and dates JPM ch,..

Date Dater

/

Date JPM 263000-01 Rev. 0 07/31/96 26300001.JPM Read to the operator the following information:

JPM 263000-01 Rev. 0 07/31/96 26300001.JPM Instructor Note This JPM was written to simulate shutdown of the actual in-service charger and then to simulate startup of the actual standby charger.

INITIAL CONDITIONS:

1. The plant is operating at 100% power.
2. Maintenance is planned on the in-service 250 VDDC battery charger.

INITIATING CUES:

The OSS directs you to shift 250 VDC battery chargers.

This task IS NOT time critical.

Inform the evaluator when you have completed the task.

SIMULATOR SETUP: N/A MALFUNCTIONS: NONE INSTRUCTOR ACTIONS:

1. Obtain OSS permission to perform JPMs in the Essential Switchgear Rooms.
2. Read initial conditions and initiating cues to the operator.

TASK STANDARDS:

1. 1D43 (44) CKT 01 open
2. 1D43 (44) CKT 02 open
3.

1D40 CKT 03 (CKT 02) opened

4. 1B3203 (4202) opened
5.

1B4202 (1B3203) is ON

6. The following are verified:

(a) Float/Equalize switch is in FLOAT (b) Equalizing charge timer switch is set at zero (c) AC POWER breaker 1D44 (1D43) CKT 01 OFF (d) DC OUTPUT breaker 1D44 CKT 02 (1D43 CKT 02 and CKT 03) OFF.

7.

1D40 CKT 02 (CKT 03) closed

8. 1D44 (1D43) CKT 02 closed
9. 1D44 (1D43) CKT 01 closed REQUIRED MATERIALS: 01-388 GENERAL

REFERENCES:

01-388, Sections 6.0, 5.2, 5.3, 3.3, 3.4 JPM 263000-01 Rev. 0 26300001.JPM 07/31/96

PERFORMANCE INFORMATION NOTE:

Critical steps are denoted with a "C". Failure to meet the standard for this step constitutes failure.

Time Start PERFORMANCE STEP:

Notify the control room of the anticipated Critical:

annunciator 250 VDC CHARGER 1D43 (44)

TROUBLE [1C0SB, D-5 (C-4)].

STANDARD:

Control Room Notified COMMENTS: Role play control room communications as necessary.

PERFORMANCE STEP:

Open the AC POWER circuit breaker Critical: C 1D43 (44) CKT 01 at battery charger 1D43 (44).

STANDARD:

1D43 (44) CKT 01 open.

COMMENTS:

Cue: Acknowledge breaker positioning.

PERFORMANCE STEP:

Open the DC OUTPUT circuit breaker Critical: C 1D43 (44) CKT 02 at battery charger 1D43 (44).

STANDARD:

1D43 (44) CKT 02 open.

COMMENTS:

Cue: Acknowledge breaker positioning.

PERFORMANCE STEP:

Verify 250 VDC CHARGER 1D43 (44) TROUBLE Critical:

[1C08), D-5 (C-4)] annunciator is reset.

STANDARD:-

Control room contacted.

COMMENTS: Role play control room communications as necessary.

JPM 263000-01 Rev. 0 07/31/96 26300001.JPM PERFORMANCE STEP:

Open breaker 1B3203 on MCC 1B32 (1B4202 on Critical: C MCC 1B42).

STANDARD:

1B3203 (4202) opened.

COMMENTS:

Cue: Acknowledge breaker positioning.

PERFORMANCE STEP:

Verify breaker 1B4202 on MCC 1B42 (1B3203 on Critical: C MCC 1B32) is ON.

-STANDARD:

1B4202 (1B3203) is ON.

COMMENTS:

Cue: Acknowledge breaker positioning.

PERFORMANCE STEP:

Verify battery charger 1D43 ( 1D44) is not in service Critical:

per section 5.2 (5.3) Battery Charger Shutdown.

STANDARD:

Opposite charger is shutdown.

COMMENTS: Examinee may state that the applicable battery charger shutdown was just completed.

PERFORMANCE STEP:

On Charger 1D44 (1D43), verify the following:

Critical: C (a) Float/Equalize switch is in the FLOAT position.

(b) Equalizing charge timer switch is set at zero.

(c) AC POWER breaker 1D44 (1D43) CKT 01 is in the OFF position.

(d) DC OUTPUT breaker 1D44 CKT 02 (1D43 CKT 02nd CKT 0

) is/are in the OFF position..

'Y STANDARD:

The following are verified:

(a) Float/Equalize switch is in FLOAT.

(b) Equalizing charge timer switch is set at zero.

(c) AC POWER breaker 1D44 (1D43) CKT 01 OFF.

(d) DC OUTPUT breaker 1D44 CKT 02 (1D43 CKT 02 and CKT 03) OFF.

COMMENTS:

Cue: Acknowledge breaker and switch positioning.

PERFORMANCE STEP:

Close circuit breaker 1D40 CKT 02 (CKT 03) on Critical: C panel 1D40.

STANDARD:

1D40 CKT 02 (CKT 03) closed.

COMMENTS:

Cue: Acknowledge breaker positioning.

JPM 263000-01 Rev. 0 07/31/96 26300001.JPM PERFORMANCE STEP:

Notify the control room of the anticipated Critical:

annunciator 250 VDC CHARGER ID44 (43)

TROUBLE [1C08B, C-4 (D-5)].

-STANDARD:

Control room notified.

COMMENTS: Role play control room communications as necessary.

PERFORMANCE STEP:

Close the DC OUTPUT circuit breaker 1D44 (1D43)

Critical: C CKT 02 on Charger 1D44 (1D43).

STANDARD:

1D44 (1D43) CKT 02 closed.

COMMENTS:

Cue: Acknowledge breaker positioning.

PERFORMANCE STEP:

Confirm that the DC VOLTS meter on Critical:

Charger 1D44 (1D43) indicates the same as the value of DC VOLTS on panel 1D40.

STANDARD:

DC Voltage values compared COMMENTS: CUE that charger and bus volts are a ima*tow equal.

6 J D*,Dc PERFORMANCE STEP:

Confirm that DC AMPERES meter on Critical:

Charger 1D44 (1D43) indicates zero after an initial surge.

STANDARD:

DC Amperage response confirmed.

COMMENTS: CUE that DC amps surge and then return to zero.

PERFORMANCE STEP:

Check battery charger 1D44 (1D43) for grounds Critical:

before placing unit in service. (Readings taken with the Ground Detector Switch in POS GRD and in NEG GRD positions.)

STANDARD:

Battery checked for grounds.

COMMENTS: CUE that both the POS GRD and NEG GRD readings are approximately 1/2 the DC bus voltage.

JPM 263000-01 Rev. 0 07/31/96 26300001.JPM PERFORMANCE STEP:

Notify the control room of the reset of annunciator Critical:

250 VDC CHARGER 1D44 (43) TROUBLE [1C08B, C-4 (D-5)] is anticipated.

STANDARD:

Control room notified.

COMMENTS: Role play control room communications as necessary.

PERFORMANCE STEP:

Close the AC POWER circuit breaker 1D44 (1D43)

Critical: C CKT 01 on charger 1D44 (1D43) and confirm AC ON light on front panel is energized.

STANDARD:

1D44 (1D43) CKT 01 closed.

COMMENTS:

Cue: Acknowledge breaker positioning and white light is ON.

PERFORMANCE STEP:

If the battery's state of charge is low, observe that Critical:

the DC AMPERES meter on Charger 1D44 (1D43) indicates an upscale value.

STANDARD:

DC amps observed.

COMMENTS: CUE that DC Amps are slightly greater than bus amps.

PERFORMANCE STEP:

Verify annunciator 250 VDC CHARGER 1D44 (43)

Critical:

TROUBLE [1C08B, C-4 (D-5)] is reset.

STANDARD:

Control Room Notified Time Stop TERMINATING CUES: None JPM 263000-01 Rev. 0 07/31/96 26300001.JPM COMMENTS: Role play control room communications as necessary. Annunciator has reset.

VERIFICATION OF COMPLETION JPM #: 263000-01 JPM

Description:

Shift 250 VDC Battery Chargers Operator:

Evaluator:

Licensee:

Eli RO E

SRO El SRO Cert Eli STA Result:

[]SATISFACTORY FE UNSATISFACTORY COMMENTS/FEEDBACK: (Note any trainee discrepancies or misperformed steps.)

Evaluator's Signature 26300001.JPM Date JPM 263000-01 Rev. 0 07/31/96 QF-1 030-11 Rev. I (FP-T-SAT-30)

Cod. to N C-*

JOB PERFORMANCE MEASURE (JPM)

Comrnmied to Nr,1ac*",Exellence 5~

SITE:

TASK TITLE:

JPM NUMBER:

RELATED PRA INFORMATION:

TASK NUMBERS:

KIA NUMBERS:

DAEC RESET A CONTROL BUILDING CHILLER AFTER TRIP 290003-01 REV.

2 NSPEO 43.02 290003 A4.01 (3.2/3.2) 35 LL_

APPLICABLE METHOD OF TESTING:

Discussion:

EVALUATION LOCATION:

In-Plant:

Simulator:

NSPEO/RO/SRO 7

~ Control Room:

Other:

Perform:

L-q LI-I Time for Completion:

Alternate Path /

Faulted:

TASK APPLICABILITY:

20 Minutes Time Critical:

NO Retention: Life of policy + 10yrs.

Retain in: Training Program File Disposition: Reviewer and Approver Page 1 of 11 NO I

QF-1 030-11 Rev. I (FP-T-SAT-30)

JPM 290003-01, Reset a Control Building Chiller After Trip, Rev. 2 JPM Number: 290003-01 JPM

Title:

RESET A CONTROL BUILDING CHILLER AFTER TRIP Evaluator:

Examinee:

Job

Title:

Start Time Date:

Finish Time PERFORMANCE RESULTS:

SAT:I UNSAT:ZIZ Delete this table if not required Procedure adequately addresses task elements.

Enter Identifier here:

Other document adequately describes necessary task elements.

Enter Identifier here:

Task elements described as attached.

EVALUATOR'S SIGNATURE:

NOTE: Only this page needs to be retained in examinee's record if completed satisfactorily. If unsatisfactory performance is demonstrated, the entire JPM should be retained.

Page 2 of 11 COMMENTS/FEEDBACK: (Comments shall be made for any steps graded unsatisfactory).

QF-1030-11 Rev. 1 (FP-T-SAT-30)

JPM 290003-01, Reset a Control Building Chiller After Trip, Rev. 2 I will explain the initial conditions, which step(s) to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this job performance measure will be satisfied.

DURING THE JPM, ENSURE PROPER SAFETY PRECAUTIONS, FME, AND/OR RADIOLOGICAL CONCERNS AS APPLICABLE ARE FOLLOWED.

INITIAL CONDITIONS:

"* Assume that you are the watchstander in the Reactor Building.

"* An accident has occurred which included a Well Water System flow transient.

"* During the transient, the operating Control Building Chiller automatically tripped.

Well Water flow has been restored to normal and is stable.

Control Building Chiller operation is necessary to maintain Control Room habitability while responding to the accident.

INITIATING CUES (IF APPLICABLE):

You are directed to restore the Control Building Chiller to service.

Use whichever Chiller is currently idle for the purpose of this JPM.

Page 3 of 11 JPM BRIEFING/TURNOVER Add required site specific JPM briefing material here:

i.e., This section is read once for the entire package of JPMs. It is not required to review this section for every JPM being performed in the package. The initial conditions and initiating cue(s)/tasks to be performed should be read and then provided to the examinee.

You may use any approved reference materials normally available including logs. Make all written reports, oral reports, and log entries as if the evolution is actually being performed.

EOP Immediate Actions are required to be performed from memory. After completing immediate action steps without using the procedure, you may then use any approved reference materials.

If this JPM is performed on the simulator, the JPM administrator should only give cues that are not indicated on the simulator. If simulator indication is sufficient to indicate the completion of a step, the JPM administrator should not have to give a cue to the trainee to continue the evolution.

QF-1030-11 Rev. 1 (FP-T-SAT-30)

JPM 290003-01, Reset a Control Building Chiller After Trip, Rev. 2 JPM PERFORMANCE INFORMATION Required Materials:

General

References:

Task Standards:

01730 01730

1.
2.
3.

4.

Control panel lights observed.

RESET pushbutton (Appendix 2, Item #1) depressed and held until cause of the trip is determined.

PS-6930A/B "Push to Reset" pushbutton depressed.

RESET pushbutton (Appendix 2, Item #1) depressed and held until it is determined that the "HIGH PRESS" light is off.

Start Time:

"NOTE: When provi Iding "Evaluator C~ues" to t,he exa Iminee, care must lbe exercis~ed to a Ivoid pr rom pting the examinee. Typically cues are only ~provided when the examinee's actions w'arirant receivng the information (i.e. the examinee looksý or asks for the indication).

NOTE:' Critical steps are marked with a "Y" below the performance step number. Failureto meet the standard for any critical step~ shall 'result in failure of this JPWI.

Performance Step:

Critical Standard:

Performance:

Comments:

Verify well water flow is stable and adequate. Otherwise start the ESW to the Verify well water flow is stable and adequate. Otherwise start the ESW to the effected chiller.

Recognize that ESW operation is not necessary with stable Well Water flow.

SATISFACTORY UNSATISFACTORY Given as an initial condition.

Page 4 of 11

QF-1 030-11 Rev. I (FP-T-SAT-30)

JPM 290003-01, Reset a Control Building Chiller After Trip, Rev. 2 SPerformance Step:

Critical fStandard:

Perform a visual inspection of the Chiller and associated components.

Visual inspection performed.

Performance:

Comments:

SATISFACTORY UNSATISFACTORY CUE: There are no abnormal indications with the Chiller or Chilled Water system.

(If asked about Chiller parameters)

CUE: Provide the parameters for a tripped Chiller as noted on Appendix 2.

Indications provided on temporary multipoint recorder are consistent with a Well Water flow transient.

Performance Step:

Critical Y (SEQ-)

Standard:

At the Chiller control panel, observe which lights are illuminated.

Control panel lights observed Performance:

Comments:

Performance Step:

Critical Standard:

SATISFACTORY UNSATISFACTORY CUE: The POWER light is ON and the SAFETY SWITCHES light is ON Performance:

Comments:

SATISFACTORY UNSATISFACTORY Operator may determine on his/her own that further investigation is not required.

If the Control Room is directed to take HS-6924A[B] STOP, then provide the following CUE:

The OSS has determined that further investigation is not required and has directed that HS-6924A[B] NOT be taken to PULL TO LOCK or STOP.

Page 5 of 11 Place the handswitch HS-6924A[B] on panel I C26A[B] to STOP if further Place the handswitch HS-6924A[B] on panel 1C26A[B] to STOP if further investigation is required.

Further investigation not required.

QF-1 030-11 Rev. 1 (FP-T-SAT-30)

JPM 290003-01, Reset a Control Building Chiller After Trip, Rev. 2 Performance Step:

I Critical Y(SEQ-)

Standard:

Performance:

Comments:

Depress and hold RESET pushbutton (Appendix 2, Item #1) while observing control panel lights. Pay particular attention to the following lights: High Pressure, Low Pressure, Freeze Up.

RESET pushbutton (Appendix 2, Item #1) depressed and held until cause of the trip is determined.

SATISFACTORY UNSATISFACTORY CUE: The "HIGH PRESS" light is illuminated.

The "LOW PRESS" and "FREEZE UP" lights are off.

Note: Operator may mention that the chiller should have fast unloaded prior to a high pressure trip.

Performance Step:

Critical Standard:

Performance:

Comments:

Release the RESET pushbutton.

RESET pushbutton released.

SATISFACTORY UNSATISFACTORY Performance Step:

Critical Standard:

Performance:

Comments:

Ensure that the condition that caused the trip is known and has been corrected before proceeding.

Recognizes well water flow transient as the cause.

SATISFACTORY UNSATISFACTORY Page 6 of 11

QF-1030-11 Rev. I (FP-T-SAT-30)

JPM 290003-01, Reset a Control Building Chiller After Trip, Rev. 2 Performance Step:

Critical Y)(SEQ-)

Standard:

The associated pressure switch must be manually reset by firmly depressing the reset pushbutton located on the switch.

PS-6930A/B "Push to Reset" pushbutton depressed.

Performance:

Comments:

Performance Step:

Critical Y (SEQ-)

Standard:

Performance:

Comments:

SATISFACTORY UNSATISFACTORY This Pressure Switch is INSIDE the left-hand panel (1C429A/B). There are 3 switches in a row at the top of the panel. PS-6930A/B is the one on the far right.

CUE: When PS-6903 A/B pushbutton is depressed, inform the operator that a click was heard.

Depress and hold RESET pushbutton (Appendix 2, Item #11) while observing control panel lights.

RESET pushbutton (Appendix 2, Item #1) depressed and held until it is determined that the "HIGH PRESS" light is off.

SATISFACTORY UNSATISFACTORY When the pushbutton is depressed, provide the following CUE:

"* The "HIGH PRESS", "LOW PRESS" and "FREEZE UP" lights are off.

"* The SAFETY SWITCHES light is OFF.

"* The ANTI-RECYCLE light is ON.

Page 7 of 11 Performance Step:

Release the RESET pushbutton.

Critical Standard:

RESET pushbutton released.

Performance:

SATISFACTORY UNSATISFACTORY Comments:

QF-1030-11 Rev. I (FP-T-SAT-30)

JPM 290003-01, Reset a Control Building Chiller After Trip, Rev. 2 Performance Step:

Critical Standard:

Performance:

Comments:

Observe the SAFETY SWITCHES light is OFF.

Observe the SAFETY SWITCHES light is OFF.

SATISFACTORY UNSATISFACTORY CUE: The SAFETY SWITCHES light is OFF.

(If asked about the ANTI-RECYCLE light)

CUE: The ANTI-RECYCLE light is ON.

COMMENTS: The Chiller is now reset and will restart automatically in 7-17 minutes. The operator may also verify that the chilled water pump is running and that the CHILLER TROUBLE annunciator on 1C26 is reset.

Terminating Cues:

Once the chiller is reset, the operator need not wait for the auto start.

Stop Time:

Page 8 of 11 11

QF-1 030-11 Rev. I (FP-T-SAT-30)

JPM 290003-01, Reset a Control Building Chiller After Trip, Rev. 2 SIMULATOR SET UP: (Modify table as necessary)

None SIMULATOR None SIMULATOR None SIMULATOR None SIMULATOR None EVENT TRIGGERS:

MALFUNCTIONS:

OVERRIDES:

REMOTE FUNCTIONS:

Page 9 of 11

QF-1030-11 Rev. I (FP-T-SAT-30)

TURNOVER SHEET

\\INITIAL CONDITIONS:

"* Assume that you are the watchstander in the Reactor Building.

"* An accident has occurred which included a Well Water System flow transient.

"* During the transient, the operating Control Building Chiller automatically tripped.

"* Well Water flow has been restored to normal and is stable.

"* Control Building Chiller operation is necessary to maintain Control Room habitability while responding to the aocident.

INITIATING CUES (IF APPLICABLE):

You are directed to restore the Control Building Chiller to service.

Use whichever Chiller is currently idle for the purpose of this JPM.

Page 10 of 11

QF-1 030-11 Rev. 1 (FP-T-SAT-30)

JPM 290003-01, Reset a Control Building Chiller After Trip, Rev. 2 ATTACHMENT I JOB PERFORMANCE MEASURE VALIDATION CHECKLIST ALL STEPS IN THIS CHECKLIST ARE TO BE PERFORMED UPON INITIAL VALIDATION AND PRIOR TO USE.

REVIEW STATEMENTS YES NO N/A

1.

Are all items on the signature page filled in correctly?

E Li L]

2.

Has the JPM been reviewed and validated by SMEs?

L1 EL

3.

Can the required conditions for the JPM be appropriately 2

L]

established in the simulator if required?

4.

Does the performance steps accurately reflect trainee's actions in El1 El accordance with plant procedures?

5.

Is the standard for each performance item specific as to what

[

Li LI controls, indications and ranges are required to evaluate if the trainee properly performed the step?

6.

Has the completion time been established based on validation data El E]

[a or incumbent experience?

7.

If the task is time critical, is the time critical portion based upon El LI LI actual task performance requirements?

8.

Is the Licensee level appropriate for the task being evaluated if El Li Li required?

9.

Is the K/A appropriate to the task and to the licensee level if

[]

Li Li required?

10.

Have the performance steps been identified and typed (Critical/

Li Li Sequence / Time Critical) appropriately?

11.

Have all special tools and equipment needed to perform the task El Li Li been identified and made available to the trainee?

12.

Are all references identified, current, accurate, and available to the E-Li El trainee?

13.

Have all required cues (as anticipated) been identified for the 1

Li Li evaluator to assist task completion?

All questions/statements must be answered "YES" or the JPM is not valid for use. If all questions/statements are answered "YES" then the JPM is considered valid and can be performed as written. The individual(s) performing the validation shall sign and date this form.

V\\alidcation Personnel /Date Validation Personnel /Date Validation Personnel/Date Validation Personnel/Date Validation Personnel/Date Validation Personnel/Date Page 11 of 11 Validation Personnel /Date Validation Personnel /Date I

D UANE ARNOLD ENERGY CENTER JOB PERFORMANCE MEASURE NUMBER: 286000-03 TASK NUMBER: NSPEO 9.08 TITLE: Manually Initiate Cable spreading Room C02 (Alternate Path)

Rev. 3 2

DEVELOPED BY:

VALIDATED BY:

REVIEWED BY:

APPROVED BY:

Instructor S -/Instructor Plant Reviewer Training Supervisor-OperatiornW TDT-3.08 Rev. 4 Date

'113/2 Date Date

DUANE ARNOLD ENERGY CENTER JOB PERFORMANCE MEASURE JPM No. 286000-03 JPM

Description:

Manually initiate cable spreading room C02 Task No.

Task

Description:

Initiate cable spreading room CO 2 using NSPEO 9.08 alternate initiation method per 01 513, Section 5.3.2 K/A

Reference:

A3.04 (3.2/3.3) 286000 2.1.30 APPLICABLE METHOD OF TESTING:

Simulate Performance X

Actual Performance Simulator In-Plant X

Control Room Time for Completion: 20 minutes 01B2crev3 JPM 286000-03 Rev. 3 1-I

JOB PERFORMANCE MEASURE VALIDATION CHECKLIST NOTE All steps of this checklist should be performed upon initial validation. Prior to JPM usage, revalidate JPM using steps 7 through 10.

JPM No. 286000-03 JPM Title Manually initiate cable spreading room C02 V

-7 K)

V/_

1. Task description and number, JPM description and number are identified
2.

Task elements identified and K/A references are included

3.

Performance location specified

a.

in-plant

b.

control room

c.

simulator

4.

Initial conditions and cues identified

a. setup, required materials, and procedure
b.

malfunctions and instructor actions

c.

initiating and terminating cues

5.

Task standards identified and verified by SME review

6.

Critical tasks/steps identified meet criteria and identified with a "C"

7.

Verify JPM steps fit the most cur t procedures Procedure Rev. 37 Date

8.

Pilot test JPM 6

6(iN'2°

a. verify cues both verbal and visual are free of conflict
b.

ensure performance time is accurate

9.

If the JPM cannot be performed as written with proper responses, then revise the JPM

10. When JPM is revalidated, SME/Instructor signs and dates JPM Date SME/Instructor SME/Instructor SME/Instructor OlB2crev3 Date Date JPM 286000-03 Rev. 3 SIMULATOR SETUP:

None EVENT TRIGGERS Trigger Trigger File Trigger Logic Statement Trigger Word Description Number Name MALFUNCTIONS:

Time Malfunction Malfunction ET Delay F. Sev. Ramp I. Sev.

No.

Title OVERRIDES:

Time Override Tag Override Description ET Delay Value.

Ramp REMOTE FUNCTIONS:

Time Remote Remote Function Title Value Ramp Function No.

JPM 286000-03 Rev. 3 O0B2crev3 K>

K>

INSTRUCTOR ACTIONS:

1. Inform OSS of performance of in-plant JPM.
2. Read initial conditions and initiating cues to the operator.

TASK STANDARDS:

1. Operator proceeds with alternate initiation method.
2. Place pilot control valve handle in the open position.
3. Proceed to master pilot valve control box at the Cardox unit and break the glass
4. Open the pilot valve for 210 seconds.
5. Verify on 1C26 in the Control Room that the CABLE SPREADING ROOM SUPPLY IV-AC-32 and EXHAUST 1V-EF-33 FANS have auto tripped by observing green lights OFF.
6. Close the master pilot control valve.

REQUIRED MATERIALS:

01 513 GENERAL

REFERENCES:

01 513, Sections 5.3, 7.4, and 8.4 01B2crev3 JPM 286000-03 Rev. 3 I-,-

I Read to the operator the following information:

JPM 286000-03 286000-03jpm.doc Rev.3 I

INITIAL CONDITIONS:

1.

The plant is operating at 100% power.

2.

1C40 annunciator F-6 (CARDOX PRE-INITIATION ALARM) was received and acknowledged. A report of smoke was received from the second floor admin bldg. After approximately 1 minute annunciator 1C40 G-6 (CARDOX INITIATED) had still NOT been received.

3.

You are the Auxiliary Operator.

INITIATING CUES:

The OSS directs you to manually initiate Cable Spreading Room C02, using the normal initiation method.

This task is not time critical.

Inform the evaluator when you have completed the task.

PERFORMANCE INFORMATION Time Start JPM 286000-03 Rev. 3 01B2crev3 NOTE:

Critical steps are denoted with a "C". Failure to meet the standard for this step constitutes failure.

PERFORMANCE STEP:

Verify the local horn sounds at Panel 1C179.

Critical:

STANDARD:

Operator listens for horn sounding.

COMMENTS:

Inform operator that no horn sound is heard. If asked after 24 second time delay has expired inform operator that no audible sound of C02 discharge is heard. If asked about red light at 1C179 inform operator it is OFF.

PERFORMANCE STEP:

Verify on Panel 1C26 in the control room that the CABLE Critical:

SPREADING ROOM SUPPLY FAN 1V-AC-32 and CABLE SPREADING ROOM EXH FAN 1V-EF-33 have Auto tripped by observing the green OFF lights turn on.

STANDARD:

Operator attempts to verify Green OFF lights are ON.

COMMENTS:

Operator goes to 1C26 or calls control room to verify 1V-AC-32 and 1V-EF-33 have auto tripped. Inform operator that CABLE SPREADING ROOM SUPPLY and EXHAUST FANS are still running. Green lights are OFF.(Red running lights are ON).

PERFORMANCE STEP:

Verify discharge using audible indication at Cable Critical:

Spreading Room access or C02 tank pressure and level decrease.

STANDARD:

Discharge verified by audible indications or tank pressure and level decrease.

COMMENTS: Cue: If asked, there is no audible indication of C02 discharge.

PERFORMANCE STEP:

Secure the Cardox System per Section 7.4 and tag it out Critical:

per Section 8.4.

STANDARD:

The Cardox is secured and tagged out.

PERFORMANCE STEP:

If no discharge occurs proceed to alternate initiation Critical: C method.

STANDARD:

Operator proceeds with alternate initiation method.

COMMENTS:

PERFORMANCE STEP:

At North Cable Spreading Room door break glass on the Critical: C pilot box and place pilot control valve handle in the OPEN position.

STANDARD:

Pilot Control Valve handle placed in the OPEN position.

COMMENTS:

PERFORMANCE STEP:

Acknowledge local alarm horn and red actuation light Critical:

(CARDOX SYSTEM ACTUATION) on Panel 1C179.

STANDARD:

Determine horn and light are off.

COMMENTS Inform operator that the horn and light are off.

JPM 286000-03 Rev. 3 01B2crev3 COMMENTS: If asked, another operator will make out the tagout and secure the Cardox System.

I PERFORMANCE STEP:

Proceed to the Master Pilot Valve Controller at the Critical: C CARDOX unit. Break the glass. Inform the control room that you are about to initiate Cardox.

STANDARD:

Locates Master Pilot Valve Controller.

COMMENTS:

Role play as control room and acknowledge that Cardox is about to be initiated.

PERFORMANCE STEP:

Open the pilot control valve for 210 seconds.

Critical: C STANDARD:

Operator opens pilot control valve and has an awareness of how long it has been open.

COMMENTS:

PERFORMANCE STEP:

Verify C02 discharge by observing C02 tank indicators.

Critical:

STANDARD:

Observes tank level and pressure gauges, or listens for flow noise to verify discharge of Cardox.

COMMENTS:

Cue: When asked, the Cardox tank level and pressure are decreasing, sound of Cardox flow is heard, frost is forming on the discharge piping.

PERFORMANCE STEP:

Verify on Panel 1C26 in the control room that the CABLE Critical: C SPREADING ROOM SUPPLY 1V-AC-32 and EXHAUST 1V-EF-33 FANS have auto tripped.

STANDARD:

Operator goes to 1C26 or calls Control Room to verify fans have tripped.

Cue: Inform operator that green lights are lit for the Cable Spreading Room Supply and Exhaust Fans. (1V-AC-32 and 1V-EF-33 have TRIPPED)

PERFORMANCE STEP:

Close the Pilot Control Valve.

Critical: C STANDARD:

Operator closes pilot control valve.

COMMENTS Cue: If the operator states that he/she will wait for 210 seconds, inform the operator that the pilot control valve has been open for 210 seconds. Otherwise wait for that period of time.

JPM 286000-03 Rev. 3 286000-03jpm.doc COMMENTS:

PERFORMANCE STEP:

Notify control room that the manual initiation process for Critical:

the Cardox System is complete.

STANDARD:

Calls control room to report completion of manual initiation.

COMMENTS:

Role play as control room and acknowledge completion of manual Cardox initiation.

PERFORMANCE STEP:

Close the pilot control valve located by the North Cable Critical:

Spreading Room door.

STANDARD:

Closes pilot control valve at North Cable Spreading Room door.

Time Stop TERMINATING CUES:

01B2crev3 Cardox System has been manually initiated per 01 513 Section 5.3. Inform trainee that the Aux Operator will secure the Cardox System per Section 7.4 and the control room is writing the tagout per Section 8.4 JPM 286000-03 Rev. 3 K>

COMMENTS Once the operator states that he will go to the cable spreading room and close the valve, inform him that the Operations Department Manager (back on the Admin Bldg. 2.d floor) will close it. (This allows you to start the next JPM from here.)

PERFORMANCE STEP:

Secure the Cardox System per Section 7.4 and tag it out Critical:

per Section 8.4.

STANDARD:

Operator proceeds to Section 7.4 to secure the Cardox System.

COMMENTS:

Cue: Inform operator that the Aux Operator will secure the Cardox System, per Section 7.4 of 01-513 and that the control room is writing the tagout.

VERIFICATION OF COMPLETION JPM No.: 286000-03 Operator:

JPM

Description:

Manually initiate cable spreading room CO2 Evaluator:

Licensee: [] RO L] STA Result:

LI SATISFACTORY COMMENTS/FEEDBACK: (No n

UNSATISFACTORY te any trainee discrepancies or misperformed steps.)

Evaluator's Signature OlB2crev3 Date JPM 286000-03 Rev. 3 F-1 NSPEO n

SRO Cert