February 13, 2003 Mr. H. A. Sepp Manager, Regulatory and Licensing Engineering Westinghouse Electric Company P.O. Box 355 Pittsburgh, PA 15230-0355
SUBJECT:
WESTINGHOUSE ELECTRIC COMPANY, REQUEST FOR WITHHOLDING INFORMATION FROM PUBLIC DISCLOSURE FOR INDIAN POINT NUCLEAR GENERATING UNIT NO. 2 (TAC NO. MB7274)
Dear Mr. Sepp:
By letter dated January 20, 2003, Entergy Nuclear Operations, Inc., (the licensee) requested that the U.S. Nuclear Regulatory Commission (NRC) review the small-break loss-of-coolant accident (LOCA) evaluation methodology for the Indian Point Nuclear Generating Unit No. 2.
This methodology was described in Westinghouse Electric Company Report Westinghouse Report WCAP-14936, Revision 0, Code Qualification Document for Best Estimate Small Break LOCA Analysis, dated August 2001. By letter dated January 24, 2003, you submitted an affidavit executed by you on January 24, 2002, requesting that WCAP-14936 be withheld from public disclosure pursuant to Title 10 of the Code of Federal Regulations (10 CFR) Section 2.790.
We are reviewing your application and the material in accordance with the requirements of 10 CFR 2.790. At this time, we believe that a portion of WCAP-14936 contains information that could be considered to be proprietary. However, in order to complete our final determination, we will need a non-proprietary version of WCAP-14936. It is our understanding that the non-proprietary document would be submitted to the NRC via the licensee within 60 days.
If you have any questions regarding this matter, I may be reached at 301-415-1457.
Sincerely,
/RA/
Patrick D. Milano, Senior Project Manager, Section 1 Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-247 cc: See next page
February 13, 2003 Mr. H. A. Sepp Manager, Regulatory and Licensing Engineering Westinghouse Electric Company P.O. Box 355 Pittsburgh, PA 15230-0355
SUBJECT:
WESTINGHOUSE ELECTRIC COMPANY, REQUEST FOR WITHHOLDING INFORMATION FROM PUBLIC DISCLOSURE FOR INDIAN POINT NUCLEAR GENERATING UNIT NO. 2 (TAC NO. MB7274)
Dear Mr. Sepp:
By letter dated January 20, 2003, Entergy Nuclear Operations, Inc., (the licensee) requested that the U.S. Nuclear Regulatory Commission (NRC) review the small-break loss-of-coolant accident (LOCA) evaluation methodology for the Indian Point Nuclear Generating Unit No. 2.
This methodology was described in Westinghouse Electric Company Report Westinghouse Report WCAP-14936, Revision 0, Code Qualification Document for Best Estimate Small Break LOCA Analysis, dated August 2001. By letter dated January 24, 2003, you submitted an affidavit executed by you on January 24, 2002, requesting that WCAP-14936 be withheld from public disclosure pursuant to Title 10 of the Code of Federal Regulations (10 CFR) Section 2.790.
We are reviewing your application and the material in accordance with the requirements of 10 CFR 2.790. At this time, we believe that a portion of WCAP-14936 contains information that could be considered to be proprietary. However, in order to complete our final determination, we will need a non-proprietary version of WCAP-14936. It is our understanding that the non-proprietary document would be submitted to the NRC via the licensee within 60 days.
If you have any questions regarding this matter, I may be reached at 301-415-1457.
Sincerely,
/RA/
Patrick D. Milano, Senior Project Manager, Section 1 Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-247 cc: See next page DISTRIBUTION:
PUBLIC PDI-1 Reading File S. Richards R. Laufer R. Caruso P. Milano S. Little F. Orr R. Landry B. Platchek, RGN-I P. Eselgroth, RGN-I M. Siemien,OGC ACRS Accession Number: ML030450108
- Concurrence by e-mail OFFICE PDI-1\\PM PDI-1\\LA*
SRXB\\SC OGC PDI\\SC NAME PMilano SLittle RCaruso MPSiemien RLaufer DATE 02/11/03 02/11/03 02/11/03 02/12/03 02/13/03 Official Record Copy
Indian Point Nuclear Generating Station Unit 2 Mr. Jerry Yelverton Chief Executive Officer Entergy Operations 1340 Echelon Parkway Jackson, MS 39213 Mr. Michael R. Kansler Senior Vice President and Chief Operating Officer Entergy Nuclear Operations, Inc.
440 Hamilton Avenue White Plains, NY 10601 Mr. Fred Dacimo Vice President - Operations Entergy Nuclear Operations, Inc.
Indian Point Nuclear Generating Units 1 & 2 295 Broadway, Suite 1 P.O. Box 249 Buchanan, NY 10511-0249 Mr. Robert J. Barrett Vice President - Operations Entergy Nuclear Operations, Inc.
Indian Point Nuclear Generating Units 3 295 Broadway, Suite 3 P.O. Box 308 Buchanan, NY 10511-0308 Mr. Dan Pace Vice President Engineering Entergy Nuclear Operations, Inc.
440 Hamilton Avenue White Plains, NY 10601 Mr. James Knubel Vice President Operations Support Entergy Nuclear Operations, Inc.
440 Hamilton Avenue White Plains, NY 10601 Mr. Christopher J. Schwarz General Manager Operations Entergy Nuclear Operations, Inc.
Indian Point Nuclear Generating Unit 2 295 Broadway, Suite 1 P.O. Box 249 Buchanan, NY 10511-0249 Mr. John Kelly Director of Licensing Entergy Nuclear Operations, Inc.
440 Hamilton Avenue White Plains, NY 10601 Ms. Charlene Faison Manager, Licensing Entergy Nuclear Operations, Inc.
440 Hamilton Avenue White Plains, NY 10601 Mr. John McCann Manager, Nuclear Safety and Licensing Indian Point Nuclear Generating Unit 2 295 Broadway, Suite 1 P. O. Box 249 Buchanan, NY 10511-0249 Mr. Harry P. Salmon, Jr.
Director of Oversight Entergy Nuclear Operations, Inc.
440 Hamilton Avenue White Plains, NY 10601 Mr. John M. Fulton Assistant General Counsel Entergy Nuclear Operations, Inc.
440 Hamilton Avenue White Plains, NY 10601 Mr. Thomas Walsh Secretary - NFSC Entergy Nuclear Operations, Inc.
Indian Point Nuclear Generating Unit 2 295 Broadway, Suite 1 P. O. Box 249 Buchanan, NY 10511-0249 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406
Indian Point Nuclear Generating Station Unit 2 Senior Resident Inspector, Indian Point 2 U. S. Nuclear Regulatory Commission 295 Broadway, Suite 1 P.O. Box 38 Buchanan, NY 10511-0038 Mr. William M. Flynn, President New York State Energy, Research, and Development Authority 17 Columbia Circle Albany, NY 12203-6399 Mr. J. Spath, Program Director New York State Energy, Research, and Development Authority 17 Columbia Circle Albany, NY 12203-6399 Mr. Paul Eddy Electric Division New York State Department of Public Service 3 Empire State Plaza, 10th Floor Albany, NY 12223 Mr. Charles Donaldson, Esquire Assistant Attorney General New York Department of Law 120 Broadway New York, NY 10271 Mayor, Village of Buchanan 236 Tate Avenue Buchanan, NY 10511 Mr. Ray Albanese Executive Chair Four County Nuclear Safety Committee Westchester County Fire Training Center 4 Dana Road Valhalla, NY 10592 Ms. Stacey Lousteau Treasury Department Entergy Services, Inc.
639 Loyola Avenue Mail Stop: L-ENT-15E New Orleans, LA 70113 Alex Matthiessen Executive Director Riverkeeper, Inc.
25 Wing & Wing Garrison, NY 10524 Paul Leventhal The Nuclear Control Institute 1000 Connecticut Avenue NW Suite 410 Washington, DC, 20036 Karl Copeland Pace Environmental Litigation Clinic 78 No. Broadway White Plains, NY 10603 Jim Riccio Greenpeace 702 H Street, NW Suite 300 Washington, DC 20001