ML023120333

From kanterella
Jump to navigation Jump to search

Review Regarding Proposed Amendment Request, Core Operating Limits Report (Colr), July 26, 2002
ML023120333
Person / Time
Site: Kewaunee 
(DPR-043)
Issue date: 11/08/2002
From: John Lamb
NRC/NRR/DLPM/LPD3
To:
NRC/NRR/DLPM/LPD3
References
TAC MB5717
Download: ML023120333 (2)


Text

November 8, 2002 MEMORANDUM TO: File FROM:

John G. Lamb, Project Manager, Section 1 /RA/

Project Directorate III Division of Licensing Project Management Office of Nuclear Reactor Regulation

SUBJECT:

KEWAUNEE NUCLEAR POWER PLANT - REVIEW REGARDING PROPOSED AMENDMENT REQUEST, CORE OPERATING LIMITS REPORT (COLR), JULY 26, 2002 (MB5717)

During the review of the subject proposed license amendment, the Nuclear Regulatory Commission (NRC) staff determined additional information was necessary to complete its review. In accordance with Nuclear Reactor Regulation Office Instruction 101, the attached draft request for additional information (RAI) was sent via e-mail to G. Riste of Nuclear Management Company, LLC (NMC) at Kewaunee Nuclear Power Plant. A conference call will be arranged between the NRC and NMC staffs. Once the NRC staff and the licensee have a common understanding of the information required, the RAI will be issued formally to the licensee.

Docket No. 50-305

Attachment:

As stated

ML023120333 OFFICE PDIII-1/PM PDIII-1/LA PDIII-1/SC NAME JLamb THarris LRaghavan DATE 11/07/02 11/07/02 11/08/02