t SWESTINGHOUSE TECHNOLOGY ADVANCED MANUAL LESSON PLAN Ch. 4.17
Title:
- Written by: Van Sickle Date: 04/01...
I
References:
- 6.
Included in lesson plan
_________________________________.1
- 1. Westinghouse Systems Manual (RPS)
- 2. '10CFR50.62 (ATWS Rule) - -, ý I t
- 3. -NUREG-1000, "Generic Implications of ATWS Events at the
,Salem Nuclear Power Plant" (1983)
- 4.
NLJREG-460, "Anticipated Transients Without Scram for Light Water Reactors" (1980)
- 5.
NUREG-1560, "Individual Plant Examination Program:
.Perspectives on Reactor Safety and Plant Performance" (1997)
- 6.
Draft Report: Regulatory Effectiveness of the Anticipated Transient Without Scram Rule" (2000)
- 7.
NUREG/CR-4674, "Precursors to Potential Severe Core Damage Accidents: 1991" Learning Objectives:
I.
Define the term "anticipated transient without scram" (ATWS).
- 2.
Describe the most limiting (most severe) ATWS case for a pressurized water reactor (PWR).
3.
List three parameters or components that affect a plant's sensitivity to an ATWS event.
- 4. ' Describe the modification' i ade to Westinghouse reactor trip breakers after the Salem ATWS.
- 5.
State the functions of the ATWS mitigation system.
- 6.
List three event tree considerations (headings) used in estimating the conditional core dariage probability of ATWS sequences.
Page 1 of 8 4/6
WESTINGHOUSE TECHNOLOGY ADVANCED MANUAL LESSON PLAN Ch. 4.7
Title:
ATWS Written by: Van Sickle IDate: 04/01 Introduction 4.7.1 Introduction Learning Objective 1
- 1. Definition: anticipated operational occurrence (AOO) as defined in 10CFR50.62, Appendix A, followed by failure of reactor trip portion of protection system specified in GDC 20 of Appendix A.
- 2.
AOO def. (from 10CFR50, App. A definitions): those conditions of normal operation that are expected to occur one or more times during life of nuclear power unit (e.g., main generator trip, LOOP, etc.).
RPS Design 4.7.2 Reactor Protection System Design Fig. 4.7-1
- 1. Tripping of one reactor trip breaker is enough to trip reactor.
- 2.
Bypass breakers are installed to allow testing of RPS without tripping reactor.
- 3. Trip actuation:
- a. Input signals from transmitters received in analog section and compared to setpoint in bistables.
- b. If bistable trip setpoint is met or exceeded, trip signal is sent to logic cabinets.
- c. When proper coincidence is reached, power is removed from undervoltage coils, and reactor trips.
ATWS Historical 4.7.3 ATWS Historical Background
Background
- 1. Possible source of concern in plants as early as 1968 in discussions between ACRS, regulatory staff, reactor instrument designers.
- 2.
Separation of control and protection functions found to be adequate.
Page 2 of 8
WESTINGHOUSE TECHNOLOGY ADVANCED MANUAL LESSON PLAN Ch.- 4.7
Title:
ATWS Written by: Van Sickle..
.[Date:
04/01-..
"3. In 1969, emphasis placed on (a) evaluating likelihood of colm(m6n-moide failures of RPS and (b) analyzing consequences of postulated ATWS events.
Learning Objective 2
- 4.
Worst case for PWR: loss of feedwater ATWS. Analysis:
a: After loss of feed, without trip on loss of heat sink protection signal, heat input from reactor and loss of heat "removal in SGs increase RCS temperature.
- b. Coolanit xpansion due to RCS temperature increase causes laige insurge into PZR; which compresses steam bubble and causes pressure to rise rapidly. Control systems not assumed to operate'to limit pressure.
- c. RCS temperature increase causes steam pressure to increase to'poirnt of lifting SG safety valves. AFW cannot keep up with steam flow, and SGs dry out. RCS temperature increases at faster rate.
- d. If MTC is-negative, some negative reactivity added by increasing RCS temperature, but not enough to prevent PZR from going'sblid. -RCS pressure increases rapidly to > 3000 psia.
Learning Objective 3
- f. Severity (peak pressure reached) affected by:
I Value'ofMTC -' determines whether & how much negative reactivity is added w/ tý'mperature increase.
Worst at BOL:
o PZR volume-affects time to reach solid conditions.
S -'PZR safety valve capacity - determines coolant outflow when plant is solid, affects ultiirnate pressure reached.
Secondary inventory - affects diyout time for Sgs.
Whether turbine trips - tripping'lengthens dryout time for SGs.
Page 3 of 8
WESTINGHOUSE TECHNOLOGY ADVANCED MANUAL LESSON PLAN Ch. 4.7 1
Title:
ATWS Written by: Van Sickle IDate: 04/01 Operational 4.7.4 Operational Occurrences Occurrences Salem ATWS 4.7.4.1 Salem ATWS
- 1. First event (02/22/83): Salem Unit 1 at 20% power w/ one main feed pump operating & second pump at minimum speed.
- a. During transfer of loads from offsite to main generator, limit switch failure causes loss of nonvital distribution bus affects operating MFP control power, one RCP, CR lighting, 125-Vac miscellaneous distr. panel.
- b. Loss of distr. panel causes loss of nonvital indications in CR, including MFP indications, steam & feed flows.
- c. SG levels decrease to low-low level trip setpt.; trip breakers fail to open.
- d. Operator manually trips reactor 3.5 see later, masking failure of auto trip.
- 2.
Second event (02/25/83): Salem at 12% power w/ manual feed control.
- a. W/ difficulty in controlling levels, one SG drops to low-low level setpt. No auto trip, but first-out annunciator indicates trip.
- b. After another operator notices no trip, plant is tripped 23 see after auto trip signal developed.
- c. Tests are performed to verify proper operation of RPS. Trip breakers fail to open on demands by auto trip signals.
Mechanical interference in trip breaker mechanisms prevents proper operation.
Page 4 of 8
WESTINGHOUSE TECHNOLOGYADVANCED MANUAL LESSON PLAN Breaker Malfunction 4.7.4.2 Breaker Malfunction Fig. 4.7-2
- 1. Normal operation of breaker design at time of Salem event:
- a. When no trip signal, undervoltage coil is energized & holds main trip shaft such that breaker is closed.
lTrip' signa l de-ene:gizes UV coil.
- c. Spring'pulis up on ann, which causes main trip shaft to rotate in counterclockwise direction.
ad.
Rotation of main triposhaft allows trip spring to pull trip bar igto the left, whichinopens trip breaker and removes power from, CRDMs. 'At Salem, UV coils operated properly, but mechanical interference in mechanisms prevented trip breakers from op eining.
- e. On manual trip, shunt trip coil is energized in addition to UV coil being de-energized. Energizing shunt trip coil
" cpushes bar attached to main trip shaft to the right, causing counterclockwise rotation of main trip shaft and the rest of the mechanical sequence described above. Manual trip
-~
work~d'at Salem.
- 2.
Similar breaker proslems found at McGuire in 1987. NRC Bulletin 88-01 issued as resiilt.
Plant Modifications 4.7.5 Plant Modifications Reactor Trip 4.7.5.1 Reactor Trip'Breakers' Breakers Fig. 4.7-3.
Westinghouse trip br~eaker design modified so that auto trip Learning Objective 4 fredundantly de-6;engizes UV coil & energizes shunt trip coil.
Page 5 of 8
WESTINGHOUSE TECHNOLOGY ADVANCED MANUAL LESSON PLAN Ch. 4.7
Title:
ATWS Written by: Van Sickle I Date: 04/01 ATWS Rule 4.7.5.2 ATWS Rule Requirements Requirements
- a. Required to be independent of RPS from sensor output to interruption of power to control rods.
- b. Required for CE, B&W because of high percentage of time operating w/ positive or slightly negative MTC.
- c. Not required for Westinghouse because of larger PZR safety valves and low percentage of time operating w/ positive or slightly negative MTC.
- 2.
ATWS mitigation system Learning Objective 5
- a. Required by ATWS Rule to auto initiate AFW & initiate turbine trip under conditions indicative of an ATWS, with equipment from sensor to final actuation device that is diverse from reactor trip system.
- b. Typically non-safety-related, nonvital powered, microprocessor based.
Fig. 4.7-4
- c. Trojan AMSAC: Actuates on low-low level in 3/4 SGs (25 sec delay) within 6 min of turbine load having exceeded 40%.
Fig. 4.7-5
- e. IP3 AMSAC software problems from poor maintenance practices & poor quality assurance.
Page 6 of 8
"WESTINGHOUSE TECHNOLOGY ADVANCED MANUAL LESSON PLAN Ch.74.7 ITitle: ATWS Written by: Van Sickle F Date: 04/01 -
PRA Insights' 4.7.6
-PRA Insights..
Historical 4.7.6.1 Historical
- 1. NUREG-460, ATWS Task Force, SECY-83-293.
Draft report is included
- 2. 'Conclusions-of draft report issued by Nuclear Regulatory in this lesson plan.
Research:
- a. Required hardware modifications have been implemented (1986 - 1990 typical). DSS or something may have to be revisited for We~tinghouse if fuel changes'mean more operation with less negative MTCs.
- b. Goal-of 1 _0E-05/RY for'P(ATWS) has been met for all reactor types. Large decrease in frequency of auto trips.
Better than expected improvements in RPS reliability.
- c. Trip breaker reliability is key. Industry programs to maintain reliability still needed.
- d. Large uncertainty in'RPS reliability estimates; much more operating experience needed to generate sufficient system demands. Hence, ATWS Rule requirements still needed.
- e. Costs of implementation much less than expected. Fewer than expected spurious trips caused by ATWS mitigation equipment.
- 3. NUREG-1560 conclusions:
- b. ATWS is important contributor at 2,Westinghouse plants (Beaver Valley 1 & Indian Point 3) because they operate w/
some or all PORV block valves closed.
.5 Page 7 of 8
I WESTINGHOUSE TECHNOLOGY ADVANCED MANUAL LESSON PLAN Ch. 4.7 ITitle: ATWS Written by: Van Sickle IDate: 04/01 Plant Event Fig. 4.7-6(a) shows event significance (in CCDP) vs. other Harris events.
Fig. 4.7-6(b) shows Harris ATWS event tree. Function headings provide answer to Objective 6.
Summary 4.7.6.2 Plant Event
- 1. Harris 1 event (06/03/91):
- a. RCS low flow trip signal developed during calibration; B trip breaker opened, but A breaker did not.
- b. Cause of failure: failed circuit board due to improper maintenance.
- c. Had both trip breakers not opened, conditional core damage probability: 6.6E-06.
- d. 4 ATWS sequences result in core damage. Dominant sequence is sequence 2 in Fig. 4.7-6(b), which is ATWS*(failure to manually insert control rods)*(primary pressure is limited)*(AFW successfully actuates)*(failure of emergency boration) 4.7.7 Summary Page 8 of 8
TRANSIENT 5.01 RAMP LOAD INCREASE, 50 - 100%, 5%/MIN Initial Conditions:
BOL Bank D Rod Position: 84 steps S Tavg:5 70.3 °F
-' J Charging flow provided by one centrifugal charging pump Pressurizer'Pressuie: 2235 psig All control systems in automatic:---'
Nu~lear Power:50%
Iiitiating Event: 5%/mm load increase' Point Explanation.
- 1.
'Generator load increases as'the control valves open in response to the 5%/min load increase command input by the operator at the turbine EHC station.
- 2.
Bank D rod position increases as outward motion is called for by the power mismatch
.(turbine load increasing relative to nuclear power) and 'emperature mismatch (T,*f> T.vg) circuits of the rod control systef.
mi.
- 3.
Nuclear power increases'in response to the positive reactivity. added by rod with'drawal.'
- 4.
Pressurizer level drops slightly at the start of the transient due to the slight cooling of the "reakctdr coolant caused by the power mismatch, withý turbine load > nuclear power. Note: The
-decrease in T.vg cannot be distinguished on the Tavg plot.
- 5.
TVg increases as the rods are withdrawn and nuclear power increases. Over the time interval in which Tavg is increasing, nuclear power exceeds turbine load.
- 6.
Tref increases with generator load (Tef varies linearly with turbine P,),,-.
- 7.
Charging flow initially increases as the pressurizer level drops relative to the setpoint (which is unchanged at the start of the transi6nt with rio change in T.,g). Chairging flow continues to increase with pressurizer level less than the level setpoint (both the level and the setpoint are constantly changing du'ring the'transieiht). Later, charging flow decieases when the actual level exceeds the setpoint.
- 8.
Bank D rod position increases at a slower rate (and sometimes stops) during the 10 min interval as the total error input to the rod control system becomes small. During the intervals of constant rod position, the power mismatch circuit calls for rod insertion (due to the nuclear power increasing faster than the rate of turbine load increase), while the temperature mismatch circuit still calls for rod withdrawal (Trf> Tavg). (Note: Although it is difficult to see on the plots, close inspection of the recorded data for this transient reveals that there are half-minute intervals in this time frame when the temperature error exceeds 2TF [enough for slow rod motion], but rods don't move. This means that during those intervals the power mismatch is of comparable magnitude and opposite sign.)
TRANSIENT 5.01 (CONT'D)
Point Explanation Westinahouse Technoloay Advanced Course Transient 5.01 Guide Rev 0102
-USNRC Technical Training Center 5.01-1
Westinghouse Technology Advanced Course Transient 5.01 Guide
- 9.
Steam flow increases as the control valves open to increase load.
- 10.
Steam generator level initially swells with the load increase.
- 11.
Feed flow increases steadily throughout the transient as the steam generator water level control system attempts to match steam and feed flows. The slight decrease in feed flow very early in the transient is the result of the level control system response to the initial swell in steam generator level.
- 12.
Steam pressure decreases as the control valves are opened. dQ/dt = UA(Tavg - T,,); Tavg is increasing and Tt (also PJ) is decreasing throughout the load change as dQ/dt increases.
Note 1: The starting bank D rod position of 84 steps is not typical for a plant operating at 50% power.
The rods were initially diluted in to their starting positions so that the power change could be completed with all control systems in automatic and with Tavg maintained on program throughout. Trojan's relaxed axial offset technical specification is not very restrictive on AFD, so starting with the bank D rods halfway in does not place the plant in an action statement.
Note 2: At steady state at the end of the transient, nuclear power = secondary load, so Tavg is unchanging. As for the reactivity balance, the negative reactivity added by the power defect associated with the power change is balanced by the positive reactivity added by the rod withdrawal, so that the net endpoint p = 0.
What this transient illustrates:
- 1. The plant response to a normal power increase controlled at the turbine EHC system station.
- 2. The actions of the rod control and pressurizer level control systems.
- 3. The initial swell in steam generator level associated with a power increase.
- 4. The programmed increase in Tavg and decrease in steam pressure associated with a power increase.
USNRC Technical Training Center 5.01-2 Rev 0102 USNRC Technical Training Center 5.01-2 Rev 0102
TRANSIENT 5.02 RAMP LOAD DECREASE, 100 - 50%, 5%/MIN Initial Conditions:
BOL Bank D Rod Position: 219 steps Tayg: 585.3 'F Charging flow provided by one centrifugal charging pump Pressurizer Pressure: 2235 psig All control systems in automatic Nuclear Power: 100%
Initiating Event: 5%/min load decrease Point Explanation
- 1.
Generator load decreases as the control valves close in response to the 5%/min load decrease command input by the operator at the turbine EHC station. The "holdup" in the load decrease over the second and third minutes of the transient appears to be characteristic of the turbine EHC system.
- 2.
Bank D rod position decreases as inward motion is called for by the power mismatch (turbine load decreasing relative to nuclear power) and temperature mismatch (TTe < Tavg) circuits of the rod control system.
- 3.
Nuclear power decreases in response to the negative reactivity added by rod insertion.
- 4.
Pressurizer level increases slightly at the start of the transient due to the slight heatup of the reactor coolant caused by the power mismatch, with turbine load < nuclear power. Note: The increase in T.,g is difficult to distinguish on the Tayg plot.
- 5.
T..g decreases as the rods are inserted and nuclear power decreases. Over the time interval in which Tavg is decreasing, nuclear power is less than turbine load.
- 6.
T,, decreases with generator load (Tef varies linearly with turbine Pimp).
- 7.
Charging flow initially decreases as the pressurizer level rises relative to the setpoint (which is unchanged at the start of the transient with little change in TaVg). Charging flow later increases when the actual level decreases relative to the setpoint (both the level and the setpoint are constantly changing during the transient).
- 8.
Steam flow decreases as the control valves close to decrease load.
- 9.
Feed flow decreases as the steam generator water level control system closes the main feed regulating valves to match steam and feed flows.
- 10.
Steam pressure increases as the control valves close. dQ/dt = UA(TBvg - Tst.); Tavg is decreasing and T,,t (also P,,) is increasing throughout the load change as dQ/dt decreases.
TRANSIENT 5.02 (CONT'D)
Note 1: For this transient only, the turbine EHC system was modified to permit a rate-controlled load Wo~~~~f~~~n~
hmfllflloAdace ous USNRC Technical Training Center Transient 5.02 Guide Jtll V
-V n.UL-1
Westinghouse Technology Advanced Course Transient 5.02 Guide decrease. Typically, with a GE EHC system, a load decrease proceeds as fast as the control valves can close in response to the operator pushing the load decrease pushbutton or decreasing the valve position limit with the potentiometer.
Note 2: At steady state at the end of the transient, nuclear power = secondary load, so Tavg is more or less unchanging. As for the reactivity balance, the positive reactivity added by the power defect associated with the power change is balanced by the negative reactivity added by the rod insertion, so that the net endpoint p = 0.
What this transient illustrates:
- 1. The plant response to a normal power decrease controlled at the turbine EHC system station.
- 2. The actions of the rod control and pressurizer level control systems.
- 3. The programmed decrease in T.yg and increase in steam pressure associated with a power decrease.
1.A
,_a ran g
Ci.
11 LI Rev 0102 I TQTTlD I, Ir h
I Ir 5.02-2
TRANSIENT 5.03 RAPID LOAD DECREASE, 100 - 90%
Initial Conditions:
BOL Bank D Rod Position: 219 steps T.vg: 585.1 'F Charging flow provided by one centrifugal charging pump Pressurizer Pressure: 2235 psig All control systems in automatic Nuclear Power:100%
Initiating Event: Rapid closure of turbine control valves with the valve position limiter Point Explanation
- 1.
Generator load decreases as the control valves close in response to the rapid reduction of the valve position limiter potentiometer setpoint by the operator at the turbine EHC station. The decrease in load occurs much more slowly than the almost instantaneous control valve closure, apparently due to the relatively large amount of steam (downstream of the control valves in the high pressure turbine and in the MSRs) that is still available to drive the turbine elements.
- 2.
Tr decreases with generator load (Trf varies linearly with turbine Pimp).
- 3.
Bank D rod position decreases at or near the maximum rate (72 steps/min) as rapid inward rod motion is called for by the power mismatch (turbine load decreasing relative to nuclear power) and temperature mismatch (T,,f < Tavg) circuits of the rod control system.
- 4.
Nuclear power decreases in response to the negative reactivity added by rod insertion and (to a small extent) by the increase in reactor coolant temperature (discussed in point 5 below).
- 5.
Pressurizer level increases at the start of the transient due to the heatup of the reactor coolant caused by the power mismatch, with turbine load < nuclear power.
- 6.
T,,g increases at the start of the transient due to the power mismatch, with turbine load <
nuclear power. Note that, although it is somewhat difficult to see on the plots, the increase in the Tevg indication lags the increase in pressurizer level (which indicates the increase in actual Tavg) because of the RTD manifold arrangement and loop transport time.
- 7.
Charging flow initially decreases as the pressurizer level rises relative to the level setpoint (which is unchanged at the start of the transient with T vg > full-load Tavg).
- 8.
Steam flow decreases as the control valves close to decrease load.
- 9.
Feed flow decreases as the steam generator water level control system closes the main feed regulating valves to match steam and feed flows.
- 10.
Steam generator level initially shrinks with the load decrease.
TRANSIENT 5.03 (CONT'D)
Point Explanation Westingyhouse Technoloa, Advanced Course Transient 5.03 Guide USNRC Technical Training Center 5.03-1 Rev 0102
Westin~bouse Technolomrv Advanced Course Taset50 ud
- 11.
Feed flow increases in response to the level error resulting from the initial shrink.
- 12.
Steam pressure increases as the control valves close. dQ/dt = UA(Tavg - T,.); T,ýt (also Pst) is increasing as the turbine load (and dQ/dt) is decreased. The increase in Ts, is exaggerated a bit by the increase in Tavg.
- 13.
Rod insertion and a small mismatch between nuclear power and secondary load bring Tayg down toward Tre, Note: At steady state at the end of the transient, nuclear power = secondary load, so Tayg is more or less unchanging. As for the reactivity balance, the positive reactivity added by the power defect associated with the power change is balanced by the negative reactivity added by the rod insertion, so that the net endpoint p = 0.
What this transient illustrates:
- 1. The plant response to a short, rapid power decrease initiated at the turbine EHC system station with the valve position limiter.
- 2. The actions of the rod control and pressurizer level control systems.
- 3. The initial shrink in steam generator water level associated with a power decrease, and the response of the steam generator water level control system.
- 4. The programmed decrease.in Tavg and increase in steam pressure associated with a power decrease.
USNRC Technical Training Center 5.03-2 Rev 0102 Rev 0102 Transient 5.03 Guide S
[ /
/¥ USNRC Technical Training Center 5.03-2
TRANSIENT 5.04 RAPID LOAD DECREASE, 100 - 15%
Initial Conditions:
BOL Bank D Rod Position: 219 steps Tavg: 585.1 TF Charging flow provided by one centrifugal charging pump Pressurizer Pressure: 2235 psig All control systems in automatic Nuclear Power:100%
Initiating Event: Rapid closure of turbine control valves with the valve position limiter Point Explanation
- 1.
Generator load rapidly decreases as the control valves close in response to the rapid reduction of the valve position limiter potentiometer setpoint by the operator at the turbine EHC station.
- 2.
Trf decreases with generator load (T,*f varies linearly with turbine Pimp).
- 3.
Bank D rod position decreases at the maximum rate (72 steps/min) as rapid inward rod motion is called for by the power mismatch (turbine load decreasing rapidly relative to nuclear power) and temperature mismatch (Tf << Tavg) circuits of the rod control system.
- 4.
Nuclear power decreases rapidly in response to the negative reactivity added by rod insertion and by the increase in reactor coolant temperature, as discussed in point 7.
- 5.
Pressurizer level increases at the start of the transient due to the heatup of the reactor coolant caused by the power mismatch, with secondary load < nuclear power.
- 6.
Pressurizer pressure rises as the steam bubble is squeezed by the thermal expansion of the reactor coolant. The pressure increase is stopped by pressurizer spray.
- 7.
Tgvg increases at the start of the transient due to the power mismatch, with secondary load <
nuclear power. Note that, although it is somewhat difficult to see on the plots, the increase in the Tavg indication lags the increase in pressurizer level (which indicates the increase in actual Tavg) because of the RTD manifold arrangement and loop transport time. The increase in Tavg is limited by the actuation of the steam dumps, which limits the total primary-to-secondary power imbalance.
- 8.
Charging flow initially decreases sharply as the pressurizer level rises relative to the level setpoint (which is unchanged at the start of the transient with Tavg > full-load Tavg).
- 9.
Steam dump demand increases rapidly with the rapid reduction in Tef (the Tavg - Tmf difference rapidly increases). The maximum steam dump demand (Tayg - T,*f = 16.4°F) is reached at 12 see. All 12 steam dump valves open fully, as discussed in point 13.
TRANSIENT 5.04 (CONT'D)
Point Explanation Westinahouse Technoloey Advanced Course Transient 5.04 Guide USNRC Technical Training Center 5.04-1 Rev 0102
- 10.
Steam flow initially decreases rapidly as the control valves close to decrease load.
- 11.
Feed flow decreases as the steam generator water level control system closes the main feed regulating valves to match steam and feed flows.
- 12.
Steam generator level initially shrinks with the rapid load decrease.
- 13.
Steam flow increases (stops decreasing) as all steam dump valves open fully with a loss-of load arming signal (from the rapid reduction in turbine load) and maximum demand.
- 14.
Feed flow rapidly increases in response to the rapid increase in steam flow and to the level error resulting from the initial shrink.
- 15.
Steam pressure increases as the control valves close. dQ/dt = UA(Tavg - Ts,); T,. (also Pt) is increasing as the turbine load (and dQ/dt) is decreased. Note that the rise in steam pressure is limited by steam dump operation; after the dumps actuate, total secondary load is always >
turbine load.
- 16.
Bank D rod position stays constant over-24 sec during the second minute. At this point, the initial large input to the power mismatch circuit from the reduction in turbine load has died off, nuclear power has been decreasing faster than turbine load, and Tavg is > T,,f. The total error input to the rod control system is < 1 TF, and rod motion stops.
- 17.
Bank D rod position decreases again, at a slower rate than earlier in the transient, with Tavg
> Tf,.
Note 1: Steady-state conditions do not appear to have been reached by the end of the plotted four minutes of parameter values. Bank D rods are still being inserted by the rod control system to bring Tag down to T,,f, and nuclear power is still decreasing as a result. As Tvg decreases, the steam dump demand will trend toward 0, and secondary load will return to turbine load only..The steam dumps have been armed by a loss-of-load arming signal and will remain armed until they are reset by the operator.
Note 2: This transient is essentially identical to supplemental transient 5.OA (Rapid Load Decrease, 100
- 50%), except that many of the parameter responses are exaggerated because of the greater magnitude of the load decrease. The early-transient increases in Tavg, pressurizer level, pressurizer pressure, and steam pressure are greater than in transient 5.OA, the intervals of maximum-speed rod insertion and 100% steam dump demand are longer, and the oscillation in SG level is greater. The plant conditions at the end of the four-minute span are farther from steady state than in transient 5.OA but are changing in a similar fashion.
TRANSIENT 5.04 (CONT'D)
What this transient illustrates:
- 1. The plant response to a rapid power decrease initiated at the turbine EHC system station with the USNRC Technical Training Center 5.04-2 Rev 0102 5.04-2 Westinehouse Teehnoloav Advanced Course Transient 5.04 Guide Rev 0102 USNRC Technical Training Center
Transient 5.04 Guide ca CItJJ12ZUU3%;
ý
- thlA-A~
yfzTanin
.0 ud valve position limiter.
- 2. The actions of the rod control,pressurizer level control, and pressurizer pressure control systems.
- 3. The initial shrink in steam generator water level associated with a power decrease, and the response of the steam generator water level control system.
- 4. The actions of the steam dump control system in response to a large loss of load.
- 5. The increase in T.,g when nuclear power >> secondary load.
- 6. The programmed decrease in Tavg and increase in steam pressure associated with a power decrease.
USNRC Technical Training Center 5.04-3 RV U1U
USNRC Technical Training Center 5.04-3 Key 0u02
TRANSIENT 5.11 MANUAL REACTOR TRIP Initial Conditions:
BOL Bank D Rod Position: 219 steps Tavg: 585.1 'F Charging flow provided by one centrifugal charging pump Pressurizer Pressure: 2235 psig All control systems in automatic Nuclear Power:100%
Initiating Event: Operator depresses manual trip pushbutton Point Explanation
- 1.
Bank D rod position falls to 0 in - 2 sec when the opening of the reactor trip breakers kills power to all rod drive system coils.
- 2.
Nuclear power initially decreases rapidly in concert with the prompt drop in neutron flux associated with the trip. At - 15 sec, the rate of power decrease follows the decay of delayed neutron precursors.
- 3.
Generator load decreases rapidly to 0 when the turbine trips. The turbine trip input comes from the P-4 contact of the reactor protection system.
- 4.
Pressurizer level decreases with the increase in reactor coolant density. Reactor coolant temperature is decreasing rapidly in response to the mismatch between nuclear power (decreasing to decay heat level with the trip) and secondary load (momentarily at maximum steam dump capacity). The minimum level reached is 18.9%.
- 5.
The decrease in pressurizer pressure reflects the expansion of the steam bubble associated with the drop in pressurizer level.
- 6.
Charging flow responds to pressurizer level control system commands. Immediately following the trip, charging flow initially increases with pressurizer level < the level setpoint, then sharply decreases with level > the level setpoint (pressurizer level is decreasing with the increase in reactor coolant density, and the level setpoint is decreasing with the decrease in auctioneered high Tavg, but level and level setpoint are not in step with each other). Later, the large "bulge" in charging flow reflects the decrease in pressurizer level to below the no-load level setpoint (25%).
- 7.
Steam dump demand follows the Tavg - T2 f difference. The steam dump demand increases to maximum immediately after the trip as T,,f quickly decreases to the no-load value, then decreases as the steam dump actuation reduces Tavg below the no-load value.
TRANSIENT 5.11 (CONT'D)
Point Explanation USRCTchialTaiigete....-.
£1ev u__.
h f
Transient 5.11 Guide Rev 0102 USNRC Technical Training Center 5.11-1
Woof-hmiucu Ta-rh~nnjo A dvanced Course Transient 5.11 Guide
- 8.
Steam flow (1) decreases to 0 as the turbine steam admission valves close with the turbine trip, then (2) increases as the steam dump valves blast open in response to the turbine trip arming signal and large demand, and finally (3) returns to 0 as the steam dump valves modulate closed in response to the reduction in demand.
- 9.
Steam generator level shrinks to below the bottom of the narrow-range indicating range with the closure of the turbine steam admission valves.
- 10.
The steam generator level control system at first decreases feed flow in response to the reduction in steam flow with the trip, and then increases feed flow in response to (1) the increase in steam flow with steam dump actuation and (2) the steam generator level error (level
< setpoint) resulting from the trip-induced shrink.
- 11.
The rapid reduction in feed flow reflects feedwater isolation on reactor trip coincident with low Tayg (564°F). All feedwater regulating valves and feedwater isolation valves close with the isolation signal.
- 12.
The indicated feed flow reflects operation of the AFW system.
- 13.
Steam pressure tracks toward Pat (1092 psig) for no-load Tavg. During most of the interval defined by this point, the steam dump valves are closed, there is relatively little heat transfer from the reactor coolant in the SGs, and decay heat increases the reactor coolant temperature and, in turn, steam pressure. Toward the end of the interval, the reactor coolant temperature has increased to the no-load TVg value, and the steam dump valves are modulating to maintain the no-load Tavgsteam pressure. Ultimately, the rate of energy removal from the reactor coolant by the SGs/steam dumps equals the rate of energy addition from decay heat.
What this transient illustrates:
- 1. The plant response to a reactor trip.
- 2. The actions of the pressurizer level control system.
- 3. The initial shrink in steam generator water level associated with a turbine trip, and the response of the steam generator water level control system.
- 4. The actions of the steam dump control system in response to a turbine trip and the maintenance of no-load Tag/steam pressure after a turbine trip.
USNR Tehnicl Tainng Cnte 5.1-Z ievU:7 USNRC Technical Training Center 5.11-2 Key JUlu
TRANSIENT 5.12 RAPID LOAD DECREASE, 100 - 50%, RODS IN MANUAL Initial Conditions:
BOL Bank D Rod Position: 219 steps Tavg: 585.1 'F Charging flow provided by one centrifugal charging pump Pressurizer Pressure: 2235 psig Rod bank selector switch placed in manual Nuclear Power:100%
Initiating Event: Rapid closure of turbine control valves with the valve position limiter Point Explanation
- 1.
Generator load rapidly decreases as the control valves close in response to the rapid reduction of the valve position limiter potentiometer setpoint bythe operator at the turbine EHC station.
- 2.
Tref decreases with generator load (T,*f varies linearly with turbine Pimp).
- 3.
Bank D rod position does not change with the rod control system in manual.
- 4.
Pressurizer level increases at the start of the transient due to the heatup of the reactor coolant caused by the power mismatch, with secondary load < nuclear power.
- 5.
Pressurizer pressure rises as the steam bubble is squeezed by the thermal expansion of the reactor coolant. The pressure increase is stopped by pressurizer spray.
- 6.
Tavg increases at the start of the transient due to the power mismatch, with secondary load <
nuclear power. Note that, although it is somewhat difficult to see on the plots, the increase in the TVg indication lags the increase in pressurizer level (which indicates the increase in actual Tavg) because of the RTD manifold arrangement and loop transport time. The increase in Tavg is limited by the actuation of the steam dumps, which limits the total primary-to-secondary power imbalance. Without rod insertion to suppress nuclear power as in supplemental transient 5.OA (Rapid Load Decrease, 100 - 50%), Tvg attains a higher value than is reached in that transient.
- 7.
Nuclear power decreases in response to the negative reactivity added by the increase in Tavg.
Nuclear power drops to about 93% and stays approximately constant over the last three minutes of the transient, when there is little change in reactivity effects.
- 8.
Charging flow initially decreases sharply as the pressurizer level rises relative to the level setpoint (which is unchanged at the start of the transient with Tvg > full-load Tavg).
- 9.
Steam dump demand increases rapidly with the rapid reduction in Tef (the Tavg -Tf difference rapidly increases). The maximum steam dump demand (Tayg - Tref= 16.4°F) is reached at 23 sec. All 12 steam dump valves open fully, as discussed in point 13.
TRANSIENT 5.12 (CONT'D)
Point Explanation USNRC Technical Training Center 5.12-1 Rev IJ1UZ 5.12-1 Transient 5.12 Guide Rev 0102 USNRC Technical Training Center
Westinchbouse Technoloiev Advanced Course Taset51 ud
- 10.
Steam flow initially decreases rapidly as the control valves close to decrease load.
- 11.
Feed flow decreases as the steam generator water level control system closes the main feed regulating valves to match steam and feed flows.
- 12.
Steam generator level initially shrinks with the rapid load decrease.
- 13.
Steam flow rapidly increases as all steam dump valves open fully with a loss-of-load arming signal (from the rapid reduction in turbine load) and maximum demand.
- 14.
Feed flow rapidly increases in response to the rapid increase in steam flow and to the level error resulting from the initial shrink.
- 15.
Steam generator level increases with (1) the increase in the boiling rate in the SGs during the recovery from the initial shrink, (2) the swell in level resulting from steam dump actuation, and (3) feed flow > steam flow (note that feed flow exceeds the steam flow value of - 3 X 106 lbm/hr for the last half of the first minute).
- 16.
Tvg (and T,. - Tre,) stays constant over the last minutes of the transient, as nuclear power is equal.to total secondary load. Turbine load = - 40%; nuclear power = - 90%.
Note: At steady state at the end of the transient, nuclear power = total secondary load (turbine load +
steam dumps), so T,,g is unchanging. As for the reactivity balance, the positive reactivity added by the decrease in fuel temperature associated with the relatively small power change is balanced by the negative reactivity added by the increase in coolant temperature, so that the net endpoint p = 0.
What this transient illustrates:
- 1. The generator load response to a rapid power decrease initiated at the turbine EHC system station with the valve position limiter.
- 2. The actions of the pressurizer level control and pressurizer pressure control systems.
- 3. The initial shrink in steam generator water level associated with a power decrease, and the ensuing recovery in SG level as the boiling rate increases with increasing Tavg.
- 4. The actions of the steam dump control system in response to a large loss of load, and steam dumps serving as a significant portion of total secondary load.
- 5. The increase in T.Vg when nuclear power >> secondary load.
USNRC Technical Training Center 5.12-2 Rev IJ1UZ 5.12-2 I
I..........
. g a Transient 5.12 Guide USNRC Technical Training Center Rev 0102
TRANSIENT 5.13 RAPID LOAD DECREASE, 100 - 50%, STEAM DUMPS OFF Initial Conditions:
BOL Bank D Rod Position:.219 steps T.yg: 585.1 'F Charging flow provided by one centrifugal charging pump Pressurizer Pressure: 2235 psig Steam dump bypass interlock switches placed in off position Nuclear Power: 100%
Initiating Event: Rapid closure of turbine control valves with the valve position limiter Point Explanation
- 1.
Generator load rapidly decreases as the control valves close in response to the rapid reduction of the valve position limiter potentiometer setpoint by the operator at the turbine EHC station.
- 2.
Bank D rod position decreases at the maximum rate (72 steps/min) as rapid inward rod motion is called forby the power mismatch (turbine load decreasing rapidly relative to nuclear power) and temperature mismatch (Tr << Tayg) circuits of the rod control system.
- 3.
Pressurizer level increases greatly at the start of the transient due to the heatup of the reactor coolant caused by the power mismatch, with turbine load < nuclear power.
- 4.
Pressurizer pressure rises as the steam bubble is squeezed by the thermal expansion of the reactor coolant. The pressure increase is slowed by pressurizer spray. Pressure reaches the pressurizer PORV lift setpoint (2335 psig), after which it drops sharply.
- 5.
TVg increases at the start of the transient due to the power mismatch, with turbine load <
nuclear power. Note that, although it is somewhat difficult to see on the plots, the increase in the Tavg indication lags the increase in pressurizer level (which indicates the increase in actual T2vg) because of the RTD manifold arrangement and loop transport time. Note that rod insertion is not as effective as steam dump actuation in limiting the increase in Tavg, as Tayg attains a higher value than is reached in transient 5.12 (Rapid Load Decrease, 100 - 50%, Rods in Manual).
- 6.
Nuclear power decreases in response to the negative reactivity added by the rod insertion and the increase in Tvg.
- 7.
Steam dump demand increases rapidly to maximum with the rapid reduction in Te, (the T.,
Tef difference rapidly increases). No steam dump valves open, as shown by the steam flow trace, as the steam dump bypass interlock switches have been placed in the off positions.
- 8.
Steam flow initially decreases rapidly as the control valves close to decrease load.
- 9.
Steam generator level initially shrinks with the rapid load decrease.
TRANSIENT 5.13 (CONT'D)
Point Explanation Westinghouse Technology Advanced Course Transient 5.13 Guide Rev 0102 USNRC Technical Training Center 5.13-1
USNRC Technical Training Center 5.13-2 i{ev IJ1UL 5.13-2 Rtev 0102
- 10.
Steam pressure increases rapidly with the closure of the turbine control valves and the large increase in Tavg. Once the new control valve position is reached, turbine load and heat transfer in the SGs are essentially constant, so steam pressure must constantly increase. dQ/dt =
UA(Tavg - Tt); with an increasing Tavg, Ttm (and P,) must increase for a constant dQ/dt.
- 11.
Steam generator level increases with (1) the increase in the boiling rate in the SGs during the recovery from the initial shrink and (2) feed flow > steam flow.
- 12.
The change in bank D rod position slows as the inputs to the rod control system from the temperature and power mismatch circuits almost cancel. Ta.g is >> Trf, so the temperature mismatch circuit is calling for rod insertion, but nuclear power has been decreasing at a fast rate with turbine load constant for over a minute, so the power mismatch circuit is calling for rod withdrawal.
- 13.
The turbine trips (as indicated by the step drop in generator load) on high steam generator water level (69%).
- 14.
The reactor trips (as indicated by the step drop in bank D rod position) with the turbine trip and power > the P-7 setpoint.
- 15.
Feed flow drops to 0 as feedwater is isolated on high steam generator water level.
- 16.
Feed flow over the last two minutes of the transient reflects AFW system operation.
- 17.
Steam pressure twice increases above the setpoint for the lowest set safety valve (1170 psig),
once at - 1 min, 45 sec, and again shortly after 3 min.
- 18.
Large increases in steam flow after the trip reflect openings of the PORV and the lowest set safety valve, with most of the flow attributable to the MSSV.
- 19.
With the steam dumps unavailable, Tavg will ultimately be maintained at the saturation temperature for the PORV lift pressure instead of at no-load Tavg.
TRANSIENT 5.13 (CONT'D)
What this transient illustrates:
- 1. The generator load response to a rapid power decrease initiated at the turbine EHC system station Transient 5.13 Guide USNRC Technical Training Center
with the valve position limiter.
- 2. The actions of the rod control, pressurizer level control, and pressurizer pressure control systems.
- 3. The initial shrink in steam generator water level associated with a power decrease, and the ensuing recovery in SG level as the boiling rate increases with increasing T.v,.
- 4. The increase in Tavg when nuclear power >> secondary load.
- 5. That rod insertion (starting with bank D rods almost completely withdrawn) is not as effective as steam dump actuation in limiting the increase in T,,vg with nuclear power >> secondary load.
USNRC Technical Training Center 5.13-3 Rev 0102 Westinghouse Technoloz' Advanced Course Transient 5.13 Guide USNRC Technical Training Center 5.13-3 Rev 0102
TRANSIENT 5.14 RAPID LOAD DECREASE, 100 - 50%, STEAM DUMPS OFF, RODS IN MANUAL Initial Conditions:
BOL Bank D Rod Position: 219 steps Tavg: 585.1 'F Charging flow provided by one centrifugal charging pump Pressurizer Pressure: 2231 psig Steam dump bypass interlock switches placed in off position, Nuclear Power: 100%
rod bank selector switch placed in manual Initiating Event:- Rapid closure of turbine control valves with the valve position limiter Point Explanation
- 1.
Generator load rapidly decreases as the control valves close in response to the rapid reduction of the valve position limiter potentiometer setpoint by the operator at the turbine EHC station.
- 2.
Pressurizer level increases greatly at the start of the transient due to the heatup of the reactor coolant caused by the power mismatch, with secondary load < nuclear power.
- 3.
Pressurizer pressure rises as the steam bubble is squeezed by the thermal expansion of the reactor coolant. Pressure reaches the pressurizer PORV lift setpoint (2335 psig) twice and decreases quickly after each lift.
4*.
Tayg increases at the start of the transient due to the power mismatch, with secondary load <
nuclear power. Note that, although it is somewhat difficult to see on the plots, the increase in the Tvg indication lags the increase in pressurizer level (which indicates the increase in actual Tavg) because of the RTD manifold arrangement and loop transport time. With no rods and no steam dumps available to limit the increase in primary temperature, Tayg attains a higher value than that reached in transient 5.12 (Rapid Load Decrease, 100 - 50%, Rods in Manual) and in transient 5.13 (Rapid Load Decrease, 100 - 50%, Steam Dumps Off).
- 5.
Nuclear power decreases in response to the negative reactivity added by the increase in Ta.g.
- 6.
Steam flow initially decreases rapidly as the control valves close to decrease load.
- 7.
Steam generator level initially shrinks with the rapid load decrease.
- 8.
Steam pressure increases rapidly with the closure of the turbine control valves and the large increase in Tayg. Once the new control valve position is reached, turbine load and heat transfer in the SGs are essentially constant, so steam pressure must constantly increase. dQ/dt =
UA(Tavg - T,,); with an increasing Tavg, T5, (and P3 n) must increase for a constant dQ/dt.
TRANSIENT 5.14 (CONT'D)
Point Explanation Westinghouse Technoloiv Advanced Course Transient 5.14 Guide USNRC Technical Training Center 5.14-1 Rev 0102
- 9.
Steam generator level increases with (1) the increase in the boiling rate in the SGs during the recovery from the initial shrink and (2) feed flow > steam flow.
- 10.
The reactor trips (as indicated by the step drop in bank D rod position) on high pressurizer level.
- 11.
The large increase in steam flow after the trip reflects openings of the PORV and the lowest set safety valves, with most of the flow attributable to the MSSVs.
- 12.
Pressurizer pressure drops rapidly after the.trip with the expansion of the steam bubble that accompanies the rapid cooling of the reactor coolant.
- 13.
The charging flow trace about halfway through the second minute is characteristic of an ESF actuation. The normal charging line is isolated, and charging flow is governed by the position of flow control valve FCV-121 and the flow restrictions provided by the RCP seals (seal injection flow is maintained after the ESF actuation). The ESF actuation results from pressurizer pressure reaching the low pressure ESF actuation setpoint.
- 14.
Pressurizer level increases with ECCS injection and isolation of letdown.
What this transient illustrates:
- 1. The generator load response to a rapid power decrease initiated at the turbine EHC system station with the valve position limiter.
- 2. The actions of the pressurizer level control and pressurizer pressure control systems.
- 3. The initial shrink in steam generator water level associated with a power decrease, and the ensuing recovery in SG level as the boiling rate increases with increasing Tavg.
- 4. The increase in Tavg when nuclear power >> secondary load.
- 5. The characteristic charging flow response with an ESF actuation.
USNRC Technical Training Center 5.14-2 Key IJIUI USNRC Technical Training Center Transient 5.14 Guide --
5.14-2 R, ev 0102
Westnghuse echo~o~
Adance CorseTransient 5.21 Guide TRANSIENT 5.21 DROPPED ROD (SHUTDOWN BANK A ROD M-14)
Initial Conditions:
BOL Bank D Rod Position: 219 steps Ta,g: 585.1 TF Charging flow provided by one centrifugal charging pump Pressurizer Pressure: 2235 psig All control systems in automatic Nuclear Power: 100%
Initiating Event: Shutdown bank A rod M-14 drops completely into the core Point Explanation
- 1.
Nuclear power drops in response to the negative reactivity insertion associated with the dropped rod. Of the two power range channels plotted, the power drop is greatest on channel NI-44 because it is closest to the dropped rod and measuring power in the most affected quadrant of the core. (Shutdown bank A rod M-14 is very close to the core "comer" adjacent to NI-44. See the attached core map.)
- 2.
Bank D rod position increases with the power mismatch circuit of the rod control system calling for outward rod motion (nuclear power is decreasing relative to turbine load). The rod motion stops when bank D rods reach the automatic-rod-stop interlock setpoint of 223 steps.
- 3.
TAvg (all loops) decreases with the power mismatch caused by the dropped rod, with nuclear power < turbine load. The decrease in Tavg continues until enough positive reactivity has been added from MTC to make nuclear power = to turbine load. (The drop in coolant temperature and the positive reactivity associated with it indicate that the positive reactivity associated with the rod withdrawal of point 2 above is not enough to counteract the negative reactivity of the dropped rod.) Note the spread in the loop temperatures: loop #3, closest to the dropped rod, is affected the most (its Tavg undergoes the greatest drop); loop #2 is next closest; loop #4 is third closest; and loop #1, which "flows" through the core quadrant diametrically opposite from the quadrant containing the dropped rod, is affected the least. (Don't be fooled by the relative Tavg values and the expanded scale: the loop #4 Tavg starts out and stays higher than the other three loop T.,g's, but it decreases more than the loop #1 Tavg.) The temperature spread graphically illustrates that complete coolant mixing in the reactor and in the reactor vessel upper plenum does not occur.
- 4.
The positive reactivity from the coolant temperature drop and (to a small extent) from the rod withdrawal increases nuclear power. The effect of MTC is most obvious in the quadrant measured by NI-43, which is diametrically opposite from the location of the dropped rod.
TRANSIENT 5.22 (CONT'D)
Point Explanation USNRC Technical Training Center 5.21-1 Westinvhouse TechnoloLy-¢ Advanced Course Rev 0102
W-tng h-1se Technolo~ Advanced Course Taset52 ud 5.'
Steam pressure drops as heat transfer conditions in the SGs change due to the reduced Tavg.
The lower TaVg cannot continue to support steam pressure at its initial value. dQ/dt = UA(TSvg T,,t); dQ/dt is essentially constant with the turbine control valve position unchanging, so Tt, (and Pt) is gradually decreasing to maintain the same AT across the SG tubes.
- 6.
Generator load gradually falls off with the degraded steam pressure. The Trojan GE turbine EHC system does not employ first stage pressure feedback, so the control valves remain at their initial positions, and load becomes a function of steam pressure.
Note 1: The dropped rod is located closer to the edge of the core than any other rod, except for its symmetrical counterparts. At 100% power, any dropped rod closer to the center of the core causes a high negative flux rate trip. The core map on the MID panel in the simulator effectively illustrates the rod location.
Note 2: At steady state at the end of the transient, the negative reactivity from the dropped rod is balanced by the positive reactivity from the decrease in coolant temperature and from the slight decrease in fuel temperature associated with the slight decrease in power. The following summarizes the trends in many of the major plant parameters during this transient, steady state to steady state:
Auctioneered high Tag drops from 585.1 'F to 583.3°F.
Steam pressure drops from 792 psig to 770 psig.
Generator load drops from 1162 MW to 1143 MW (98.5%).
NI-44 power drops to 91.8%.
NI-43 power increases to 100.8%.
What this transient illustrates:
- 1. The negative reactivity associated with a dropped rod.
- 2. The spread in coolant temperatures between core quadrants, illustrating that the dropped rod affects the portions of the core closest to it the most.
USNRC Technical Training Center 5.21-2 Rev U1U
USNRC Technical Training Center 5.21-2 Transient 5.21 Guide Rev 0102t
TRANSIENT 5.22 FAST ROD WITHDRAWAL, 45% LOAD Initial Conditions:
BOL Bank D Rod Position: 103 steps Tavg: 568.7°F Charging flow provided by one centrifugal charging pump Pressurizer Pressure: 2237 psig All control systems in automatic Nuclear Power: 50%
Initiating Event: Rod control system controller failure withdraws bank D rods at 72 steps/min Point Explanation
- 1.
Bank D rod position increases at 72 steps/min in response to the controller failure.
- 2.
Nuclear power increases with the positive reactivity associated with the rod withdrawal. The increase in power is tempered somewhat by the negative reactivity associated with the increase in reactor coolant temperature.
- 3.
TaVg increases with the power mismatch caused by the rod withdrawal, with nuclear power >
turbine load. The increase in Tavg is also evident in the increase in pressurizer level.
- 4.
Steam pressure increases as heat transfer conditions in the SGs change due to the increased Tayg. dQ/dt = UA(Tavg - T.tm); dQ/dt is essentially constant with the turbine control valve position unchanging, so Tt, (and P.,) is gradually increasing to maintain the same AT across the SG tubes.
- 5.
Steam dump demand steadily increases to maximum with T
>>,g
>> Trf. Steam dump actuation does not occur (there is no change in steam flow at this point), as there is no loss-of-load arming signal.
- 6.
Pressurizer level, which is increasing because of the decrease in reactor coolant density (Tnvg is increasing), reaches the high level trip setpoint.
- 7.
Steam dump actuation brings Tvg toward no-load Tayg. The steam dumps are armed by the turbine trip, and the large initial demand (Tavg - no-load T,,g) causes all 12 steam dump valves to open. The valves modulate closed as the steam dump demand is decreased.
- 8.
Pressurizer pressure drops rapidly with the expansion of the pressurizer steam bubble associated with the post-trip reactor coolant contraction. The decreased reactor coolant temperature caused by steam dump operation increases the coolant density.
- 9.
The charging flow perturbation reflects an ESF actuation. The low pressurizer pressure ESF actuation is caused by the rapid expansion of the pressurizer steam bubble resulting from the rapid reactor coolant volume contraction following the trip.
TRANSIENT 5.22 (CONT'D)
Note 1: The "blip" in generator load at - 2 min reflects the voltage/current spike accompanying the USNRC Technical Training Center 5.ZZ-1 iiev uiui 5.22-1 Transient 5.22 Guide Rev 0102 USNRC Technical Training Center
opening of the output breakers.
Note 2: This transient is essentially the same as supplemental transient 5.2A (Slow Rod Withdrawal, 45% Load), except that the parameters change more quickly and that the reactor trip and ESF actuation occur sooner.
What this transient illustrates:
- 1. The response of the plant to a fast rod withdrawal at power, particularly the increases in reactor coolant temperature, pressurizer level, and steam pressure.
- 2. A high pressurizer level reactor trip.
- 3. A low pressurizer pressure ESF actuation.
USNRC Technical Training Center 5.22-2 Rev 0102 5.22-2 Westinehouse Technoloev Advanced Course Transient 5.22 Guide Rev 0102 USNRC Technical Training Center
TRANSIENT 5.23 FAST ROD WITHDRAWAL FROM SOURCE RANGE Initial Conditions:
BOL Bank D Rod Position: 105 steps T.yg: 558.1 TF Charging flow provided by one centrifugal charging pump Pressurizer Pressure: 2235 psig Normal plant configuration for hot standby, except S.R. and Nuclear Power: 551 cps in S.R.
I.R. trips are bypassed at NI cabinets Initiating Event: Rod control system controller failure
- withdraws bank D rods at 72 steps/min Point Explanation
- 1.
Bank D rod position increases at 72 steps/min in response to the controller failure.
- 2.
Source range power increases with the positive reactivity associated with the rod withdrawal.
- 3.
Intermediate range power also registers the increase in power caused by the rod withdrawal.
- 4.
Nuclear power (power range) is on scale when rod withdrawal has increased neutron flux sufficiently. The point of adding heat has been reached.
- 5.
Pressurizer level and T ay increase slightly after the point of adding heat has been reached.
Heat transfer from the fuel to the coolant is now great enough to raise coolant temperature.
- 6.
The reactor trip (indicated by the step drop in bank D rod position) is caused by a high positive flux rate. The turbine trip and P-7 reactor trip is not a possible reactor trip, because the source range plot illustrates that the source range instruments have not been de-energized by P-1 0 at any time during the transient.
Note: The increase in reactor power caused by the rod withdrawal raises Ta.g to a peak of 559.2 'F. The increase in coolant temperature and corresponding increase in steam pressure do increase steam flow through the steam dump valves (the steam dumps are operating in the steam pressure mode of control),
but the steam flow value is two orders of magnitude less than the range of indication and thus cannot be distinguished on the steam flow plot.
What this transient illustrates:
- 1. The response of the plant to a fast rod withdrawal starting in the source range, particularly the increase in power as measured by all three ranges of excore instruments.
- 2. A high positive flux rate reactor trip.
USNRC Technical Training Center 5.23-1 Rev 0102 5.23-1 Westintghouse Technology Advanced Course Transient 5.23 Guide Rev 0102 USNRC Technical Training Center
TRANSIENT 5.31 LOOP #1 COLD-LEG RTD FAILS HIGH Initial Conditions:
BOL Bank D Rod Position: 219 steps Tavg: 585.2'F Charging flow provided by one centrifugal charging pump Pressurizer Pressure: 2230 psig All control systems in automatic Nuclear Power:100%
Initiating Event: Loop #1 cold-leg RTD fails high Point Explanation
- 1.
Auctioneered high Ta.9 undergoes a rapid increase to > 620°F. The loop #1 Tayg becomes auctioneered high T~vg; that loop has a Tc of 630°F (the upper limit of the instrument range) because of the failed-high cold-leg RTD and a TH of> 610TF (normal).
- 2.
Bank D rod position decreases at the maximum rate (72 steps/min) because of the large temperature mismatch input to the rod control system calling for fast rod insertion. The large temperature mismatch results from the failed-high auctioneered high Tag.
- 3.
Nuclear power decreases due to the negative reactivity associated with rod insertion. The positive reactivity insertion resulting from the decrease in reactor coolant temperature, as discussed in point 4 below, is not enough to counteract it.
- 4.
Actual Tavg decreases due to the large imbalance between nuclear power and secondary load, with nuclear power decreasing rapidly. To maintain secondary load, energy must be taken from the reactor coolant, reducing its temperature.
- 5.
The pressurizer level decrease reflects the reduction in reactor coolant volume caused by the decrease in coolant temperature.
- 6.
Charging flow increases greatly with pressurizer level low relative to the level setpoint, which remains at the maximum value (61.5%) with auctioneered high Tayg > 584.7'F.
- 7.
Steam dump demand increases to 100% with the RTD failure. The T.,g - T,,f input to the loss-of-load controller is maximized with T, >> T,,,f Note that at this time the dumps have not actuated, as there is no loss-of-load arming signal (no drop in turbine load yet).
- 8.
Pressurizer pressure drifts lower as the pressurizer steambubble expands with reactor coolant contraction. The pressurizer heaters cannot maintain normal operating pressure.
- 9.
Steam pressure drops as heat transfer conditions in the SGs change due to the reduced Tang.
The lower Tag cannot continue to support steam pressure at its initial value. dQ/dt = UA(Tavg T=); dQ/dt is essentially constant with the turbine control valve position unchanging, so Ts*
(and P,.) is gradually decreasing to maintain the same AT across the SG tubes.
TRANSIENT 5.31 (CONT'D)
Point Explanation Westinahouse Technology Advanced Course Transient 5.31 Guide USNRC Technical Training Center 5.31-1 Rev 0102
- 10.
Generator load gradually falls off with the degraded steam pressure. The Trojan GE turbine EHC system does not employ first stage pressure feedback, so the control valves remain at their initial positions, and load becomes a function of steam pressure. Note: the faster dropoff in load just prior to the turbine trip reflects the response of the initial pressure limiter, a GE turbine EHC system feature which closes the control valves in response to a throttle pressure that decreases to less than 90% of a manually adjustable setpoint.
- 11.
Steam flow increases sharply at approximately 1 mrin, 30 sec. The reduction in turbine load discussed in point 10 arms the dumps on the loss-of-load controller, and the existing 100% demand causes all 12 dump valves to blast open. The steam flow increase results.
- 12.
The reactor trip (indicated by the step drop in bank D rod position) is caused by an ESF actuation on high steam flow plus low steam pressure. The high steam flow setpoint is reached with the steam dump valves blasting open, and the low steam pressure setpoint is reached as the Mteam pressure constantly decreases. Note that the ESF actuation takes place when the steam pressure is - 685 psig; the input to the low steam pressure bistable reaches the low steam pressure setpoint before actual pressure does because of the lead-lag circuit through which the steam pressure signal is processed. Note also that the other ESF actuation signals are not possible: pressurizer pressure and T.vg are not low enough yet, there is no steam line AP, and there is nothing causing containment pressure to increase.
- 13.
The charging flow perturbation reflects the ESF actuation. The initial drop in flow reflects charging line isolation; the flow settles at the relatively high value governed by the maximum opening of charging flow control valve FCV-121 (the pressurizer level is low throughout most of the transient) and the flow restriction of the RCP seals (the only path left for injection from the CVCS).
- 14.
Pressurizer level recovers with ECCS flow and letdown isolation following the ESF actuation.
- 15.
Feed flow after the trip reflects AFW system operation (main feedwater is now isolated).
- 16.
Steam flow decreases to 0, reflecting the MSIV closure associated with the high steam flow ESF actuation.
Note 1: The "blip" in generator load shortly after 2 min reflects the voltage/current spike accompanying the opening of the output breakers.
TRANSIENT 5.31 (CONT'D)
Note 2: For pt. 12, the lead-lag unit changes a ramp of f(t) = kt into k[t + (,u
- x2)(1 - eC2)] for a lead constant of T, and a lag constant of r2. For the low steam pressure portion of the high steam flow ESF actuation, 't1 = 50 sec, T2 = 5 sec. So, after the exponential term dies out, ramp kt becomes k(t + 45 see).
Westinehouse Technolosy Advanced Course Transient 5_31 Guide USNRC Technical Training Center 5.31-2 Rev 0102
Westinghouse Technology Advanced Course Transient 5.31 Guide What this transient illustrates:
- 1. The responses of the rod control, pressurizer level control, and steam dump control systems to a failed-high cold-leg RTD.
- 2. The decrease in Tavg when nuclear power << secondary load.
- 3. A reactor trip and ESF actuation on high steam flow + low steam pressure.
USNRC Technical Training Center 5.31-3 Rev U1UZ USNRC Technical Training Center 5.31-Rev 0102
Westinghouse Technology Advanced Course Transient 5.32 Guide TRANSIENT 5.32 LOOP #1 HOT-LEG RTD FAILS HIGH, - 25% LOAD Initial Conditions:
BOL Bank D Rod Position: 187 steps Tavg: 562.7°F Charging flow provided by one centrifugal charging pump Pressurizer Pressure: 2235 psig Steam dumps armed due to previous load rejection Nuclear Power: 32%
Initiating Event: Loop #1 hot-leg RTD fails high Point Explanation
- 1.
Auctioneered high T.,g increases rapidly to - 600TF. The loop #1 T.,g becomes auctioneered high Tavg; that loop has a TH of 650'F (the upper limit of the instrument range) because of the failed hot-leg RTD, an increase of some 801F above its initial value. This increase in TH increases Ta.g by - 40TF.
- 2.
Charging flowincreases greatly with pressurizer level low relative to the level setpoint, which has increased to the maximum value (61.5%) with auctioneered high Tag > 584.71F.
- 3.
Steam dump demand increases to 100% with the RTD failure. The Tavg - Tf input to the loss-of-load controller is maximized with Tavg> Trf. As discussed in point 4 below, the dump valves open immediately, as the steam dump control system is already armed in the Tavg mode.
- 4.
Steam flow increases sharply after the first several sec. With the dumps already armed and a 100% demand, all 12 dump valves blast open.
- 5.
Steam pressure decreases sharply with all 12 dump valves opening and relieving steam to the condenser.
- 6.
The reactor trip (indicated by the step drop in bank D rod position) is caused by an ESF actuation on high steam flow plus low steam pressure. The high steam flow setpoint is reached with the steam dump valves blasting open, and the low steam pressure setpoint is reached as the steam pressure constantly decreases. Note that the ESF actuation takes place when the steam pressure is - 887 psig; the input to the low steam pressure bistable reaches the low steam pressure setpoint before actual pressure does because of the lead-lag circuit through which the steam pressure signal is processed. Note also that the other ESF actuation signals are not possible: pressurizer pressure and Tavg are not low enough yet, there is no steam line AP, and there is nothing causing containment pressure to increase.
- 7.
The charging flow perturbation reflects the ESF actuation. The initial drop in flow reflects charging line isolation; the flow settles at the relatively high value governed by the maximum opening of charging flow control valve FCV-121 (the pressurizer level is below the setpoint level [61.5%] throughout the transient) and the flow restriction of the RCP seals (the only path left for injection from the CVCS).
TRANSIENT 5.32 (CONT'D)
Point Explanation USNRC Technical Training Center 5.32-1 Rev 0102
- 8.
Steam flow decreases to 0, reflecting the MSIV closure associated with the high steam flow ESF actuation.
Note 1: The "blip" in generator load at - 48 sec reflects the voltage/current spike accompanying the opening of the output breakers.
Note 2: This transient is essentially the same as transient 5.3A (Loop #1 Hot-Leg RTD Fails High, 100%) and transient 5.3B (Loop #1 Cold-Leg RTD Fails High, 100%), except that the starting power level is lower than in those transients.
What this transient illustrates:
- 1. The responses of the pressurizer level control and (already armed) steam dump control systems to a failed-high hot-leg RTD.
- 2. A reactor trip and ESF actuation on high steam flow + low steam pressure.
USNRC Technical Training Center 5.32-2 Rev 0102 Westinizhouse Technoloev3 Advanced Course Transient 5.32 Guide USNRC Technical Training Center 5.32-2 Rev 0102
Westinphouse Technolo~yv Advanced Course Taset53 ud TRANSIENT 5.33 POWER RANGE CHANNEL NI-41 FAILS HIGH Initial Conditions:
BOL Bank D Rod Position: 219 steps Tavg: 585.1 'F Charging flow provided by one centrifugal charging pump Pressurizer Pressure: 2235 psig All control systems in automatic Nuclear Power: 100%
Initiating Event: Power range channel NI-41 fails high Point Explanation
- 1.
Nuclear power (from NI-41) increases to maximum (initiating event).
- 2.
Bank D rod position decreases at the maximum rate (72 steps/min). The failed-high power range channel becomes auctioneered high nuclear power, and its step increase relative to a constant turbine load develops a large rod insertion signal in the power mismatch circuit of the rod control system.
- 3.
Actual nuclear power decreases due to the negative'reactivity associated with rod insertion.
The positive reactivity insertion resulting from the decrease in reactor coolant temperature, as discussed in point 4 below, is not enough to counteract it during this phase of the transient.
- 4.
TVg decreases due to the large imbalance between nuclearpower and turbine load, with nuclear power decreasing rapidly. To maintain turbine load, energy must be taken from the reactor coolant, reducing its temperature. The reduction in Tayg is also evident in the decreasing pressurizer level and pressurizer pressure.
- 5.
Steam pressure drops as heat transfer conditions in the SGs change due to the reduced T,,g.
The lower TVg cannot continue to support steam pressure at its initial value. dQ/dt = UA(Tavg T,,); dQ/dt is essentially constant with the turbine control valve position unchanging, so Tt*
(and Pt) is gradually decreasing to maintain the same AT across the SG tubes.
- 6.
Generator load gradually falls off with the degraded steam pressure. The Trojan GE turbine EHC system does not employ first stage pressure feedback, so the control valves remain at their initial positions, and load becomes a function of steam pressure.
- 7.
Bank D rod position stops decreasing. Over the first minute or so of the transient, the large negative input to the rod control system from the initial "spike" in auctioneered high nuclear power has been decaying off, while a large positive input due to the decrease in auctioneered high Tag relative to T,,,f has been building in. These inputs essentially cancel at-1 min, and rod motion stops. For several seconds prior to this point, the rod insertion speed is slowing, showing that the total error calling for rod insertion has decreased greatly from the initial error associated with the NI-41 failure.
TRANSIENT 5.33 (CONT'D)
Point Explanation USNRC Technical Training Center 5.33-1 Rev 0102 USNRC Technical Training Center 5.33-1 Transient 5.33 Guide Rev 0102
- 8.
Bank D rod position remains constant over the last three miin of the transient. Ordinarily, outward rod motion would result from the continued decrease in Tavg and the continued decay of the nuclear power spike, but the failed channel exceeds the overpower rod stop setpoint (103%), and this rod stop requires only a one-out-of-four coincidence.
- 9.
Nuclear power increases with the positive reactivity insertion associated with the reduction in coolant temperature after rod insertion stops.
- 10.
Tayg remains constant over the final two min of the transient. At this point, nuclear power and turbine load are essentially equal, meaning that a power mismatch that would change T.vg no longer exists.
Note: By the end of the 4 plotted min, new steady-state conditions have essentially been reached: the negative reactivity from the rod insertion is balanced by the positive reactivity from the reduction in fuel temperature associated with the power change and from the reduction in coolant temperature,.
and Tavg is constant with nuclear power equal to the turbine load, which has decreased from its initial 100% value because of the degraded steam pressure. Final steady-state values: nuclear power =
91.2%, generator load = 1079 MW, Tavg = 568.2'F.
What this transient illustrates:
- 1. The response of the rod control system to a failed-high power-range NI.
- 2. The decrease in Tavg when nuclear power < secondary load.
- 3. An overpower rod stop.
- 4. Steady-state to steady-state reactivity balances with changing parameters.
USNRC Technical Training Center 5.33-2 Rev U1UZ 5.33-2 Transient 5.33 Guide Rev 0102 USNRC Technical Training Center
WestinL-house Technoloev Advanced Course Taset53 ud TRANSIENT 5.34 STEAM DUMP LOSS-OF-LOAD CONTROLLER FAILS TO MAXIMUM DEMAND Initial Conditions:
BOL Bank D Rod Position: 219 steps T.vg: 585.1 'F Charging flow provided by one centrifugal charging pump Pressurizer Pressure: 2233 psig Steam dumps armed due to previous load rejection Nuclear Power: 100%
Initiating Event: Steam dump loss-of-load controller fails to maximum demand Point Explanation
- 1.
The initiating event increases steam dump demand to 100%.
- 2.
Steam flow increases sharply as the steam dump valves open. The dumps are already armed, and the 100% demand resulting from the controller failure causes all 12 dump valves to blast open.
- 3.
Steam generator level swells as the steam dump valves open.
- 4.
Steam pressure drops with the additional steam release associated with steam dump operation.
- 5.
Generator load gradually falls off with the degraded steam pressure. The Trojan GE tubine EHC system does not employ first stage pressure feedback, so the control valves remain at their initial positions, and load becomes a function of steam pressure.
- 6.
The reactor trip (indicated by the step drop in bank D rod position) is caused by an ESF actuation on high steam flow plus low steam pressure. The high steam flow setpoint is reached with the steam dump valves blasting open, and the low steam pressure setpoint is reached as the steam pressure constantly decreases. Note that the ESF actuation takes place when the steam pressure is - 750 psig; the input to the low steam pressure bistable reaches the low steam pressure setpoint before actual pressure does because of the lead-lag circuit through which the steam pressure signal is processed. Note also that the other ESF actuation signals are not possible: pressurizer pressure and Tvg are not low enough yet, there is no steam line _AP, and there is nothing causing containment pressure to increase.
- 7.
The charging flow perturbation reflects the ESI actuation. The initial drop in flow reflects charging line isolation; the flow then returns to a relatively high value governed by the maximum opening of charging flow control valve FCV-121 (the pressurizer level is low immediately after the ESF actuation) and the flow restriction of the RCP seals (the only path left for injection from the CVCS).
TRANSIENT 5.34 (CONT'D)
USNRC Technical Training Center 5.34-1 k(ev UIUL 5.34-1 e
0102A Transient 5-34 Guide USNRC Technical Training Center
Point Explanation
- 8.
Charging flow gradually decreases as the pressurizer level is increased by ECCS injection.
FCV-121 gradually closes to its minimum opening as the pressurizer level error (level >
setpoint) continues to increase.
- 9.
Steam dump demand returns to 0 after the turbine trip. The turbine trip which accompanies the reactor trip puts the turbine trip controller in play, and the steam dump demand falls as Ta.g decreases to < the no-load value.
Note: This transient is very similar to transient 5.32 (Loop #1 Hot-Leg RTD Fails High, 25% Load),
transient 5.3A (Loop #1 Hot-Leg RTD Fails High, 100%), and transient 5.3B (Loop #1 Cold-Leg RTD Fails High, 100%). In those transients, the already armed steam dump control system opens all steam dump valves when auctioneered high Tavg fails high, which results in a large steam dump demand.
What this transient illustrates:
- 1. The response of the (already armed) steam dump control system to a loss-of-load controller demand failure.
- 2. A reactor trip and ESF actuation on high steam flow + low steam pressure.
USNRC Technical Training Center 534-2 Rev 0102 5.34-2 Westingyhouse Technology Advanced Course Transient 5.34 Guide Rev 0102 USNRC Technical Training Center
Westinohouse Technology Advanced Course Taset53 ud TRANSIENT 5.35 IMPULSE PRESSURE CHANNEL PT-505 FAILS LOW Initial Conditions:
BOL Bank D Rod Position: 219 steps Tag: 585.2'F Charging flow provided by one centrifugal charging pump Pressurizer Pressure: 2230 psig All control systems in automatic Nuclear Power: 100%
Initiating Event: Impulse pressure channel PT-505 fails low Note: This impulse pressure channel feeds the rod control system (T,,f for the temperature mismatch circuit and Pi for the power mismatch circuit), the steam dump control system (T,,, for the loss-of-load controller), and the steam generator water level control system (the level setpoint varies linearly with Pimp from 0 - 20% load); provides one input to the P-13 permissive (turbine at-power permissive);
establishes the high steam flow setpoint for the high steam flow + low-low Tavg or low steam pressure ESF actuation in protection channel I; and supplies the C-5 interlock (automatic rod withdrawal block
< 15% load).
Point Explanation
- 1.
Tra undergoes a rapid decrease to its minimum value of 5571F (programmed T.vg for no load).
- 2.
Bank D rod position decreases at the maximum rate (72 steps/min) because of the large temperature mismatch (T,,f<< Tayg) and large power mismatch (turbine load decreasing rapidly relative to nuclear power) inputs to the rod control system calling for fast rod insertion. The large mismatches result from the failed-low impulse pressure channel.
- 3.
Nuclear power decreases due to the negative reactivity associated with the rod insertion. The positive reactivity insertion resulting from the decrease in reactor coolant temperature, as discussed in point 4 below, is not enough to counteract it.
- 4.
TVg decreases due to the large imbalancebetween nuclear power and turbine load, with nuclear power decreasing rapidly. To maintain turbine load, energy must be taken from the reactor coolant, reducing its temperature.
- 5.
The pressurizer level decrease reflects the reduction in reactor coolant volume caused by the decrease in coolant temperature.
- 6.
Charging flow increases greatly with pressurizer level low relative to the level setpoint. Both the pressurizer level and the level setpoint (a function ofauctioneered high Ta.g) are decreasing, but the pressurizer level remains below the level setpoint.
- 7.
Steam dump demand increases to 100% with the impulse pressure failure. The TVg - T,,f input to the loss-of-load controller is maximized with Tavg >> T,,f. Note that at this time the dumps have not actuated, as there is no loss-of-load arming signal (no drop in turbine load yet).
TRANSIENT 5.35 (CONT'D)
USNRC Technical Training Center 5.35-1 Rev 0102 USNRC Technical Training Center 5.35-1 Transient 5.35 Guide Rev 0102
Point Explanation
- 8.
Pressurizer pressure drifts lower as the pressurizer steam bubble expands with reactor coolant contraction. The pressurizer heaters cannot maintain normal operating pressure.
- 9.
Steam pressure drops as heat transfer conditions in the SGs change due to the reduced Tavg. The lower Tag cannot continue to support steam pressure at its initial value. dQ/dt UA(T,,vg - TJ; dQ/dt is essentially constant with the turbine control valve position unchanging, so T.tm (and Pt,) is gradually decreasing to maintain the same AT across the SG tubes.
- 10.
Generator load gradually falls off with the degraded steam pressure, and, after-1 min 24 sec, with throttling of the turbine control valves in response to the initial pressure limiter.
The Trojan GE turbine EHC system does not employ first stage pressure feedback, so at first the control valves remain at their initial positions, and load becomes a function of steam pressure. Later, the initial pressure limiter closes the control valves in response to a throttle pressure that has decreased to less than 90% of setpoint.
- 11.
Steam flow decreases first with the reduction in steam pressure and later with closure of the turbine control valves by the initial pressure limiter.
- 12.
Steam generator level decreases with the reduction in feed flow (the failed-low impulse pressure channel has driven the steam generator water level setpoint to its minimum programmed value of 33%, so feed flow is decreased to bring level down to the new setpoint) and the slow shrink associated with the continued decrease in Tavg.
- 13.
Bank D rod position stays constant over the last interval of the transient. At this point, the primary-to-secondary power mismatch has driven Tavg close to the minimum T,,f value (decreasing the temperature mismatch 6alling for rod insertion), the large initial input to the power mismatch circuit from the failed transmitter has died off, and nuclear power has been decreasing faster than turbine load for a fairly long period (a power mismatch calling for rod withdrawal). The total error input to the rod control system thus drops below 1 *F, and rod motion stops. Also, any developing total error that would cause rod withdrawal is prevented from affecting rod position by the C-5 (auto rod withdrawal block) interlock (the input to C-5 is from the failed-low channel).
TRANSIENT 5.35 (CONT'D)
Note: The protection channel I high steam flow setpoint is exceeded immediately with the impulse pressure channel failure because the setpoint is driven to its minimum programmed value, but a high steam flow ESF actuation is avoided because the reduction in steam pressure is not large enough to USNRC Technical Training Center 5.35-2 Rev 0102 Rev 0102 Westinghouse TechnoloLyv Advanced Course USNRC Technical Training Center 5.35-2
Transient 5.35 Guide Westinghouse Technology Advanced Course reach the low steam pressure setpoint.
What this transient illustrates:
- 1. The responses of the rod control and steam dump control systems to a failed-low impulse pressure channel.
- 2. The decrease in Tvg when nuclear power < secondary load.
USNR Tehnicl Tainig Cnter5.3-3 Ky IIIJ USNRC Technical Training Center 5.35-3 R¢ev 0IU0
TRANSIENT 5.36 IMPULSE PRESSURE CHANNEL PT-505 FAILS HIGH Initial Conditions:
BOL Bank D Rod Position: 148 steps Tavg: 569.5 0F Charging flow provided by one centrifugal charging pump Pressurizer Pressure: 2235 psig All control systems in automatic Nuclear Power: 50%
Initiating Event: Impulse pressure channel PT-505 fails high Note: This impulse pressure channel feeds the rod control system (T,,f for the temperature mismatch circuit and Pimp for the power mismatch circuit), the steam dump control system (Tr for the loss-of-load controller), and the steam generator water level control system (the level setpoint varies linearly with Pimp from 0 - 20% load); provides one input to the P-13 permissive (turbine at-power permissive);
establishes the high steam flow setpoint for the high steam flow + low-low Tavg or low steam pressure ESF actuation in protection channel I; and supplies the C-5 interlock (automatic rod withdrawal block
< 15% load).
Point Explanation
- 1.
Tref undergoes a rapid increase to its maximum value of 584.7'F (programmed T.,, for full load).
- 2.
Bank D rod position increases at the maximum rate (72 steps/min) because of the large temperature mismatch (Tf>> Tvg) and large power mismatch (turbine load increasing rapidly relative to nuclear power) inputs to the rod control system calling for fast rod withdrawal. The large mismatches result from the failed-high impulse pressure channel.
- 3.
Nuclear power increases due to the positive reactivity associated with the rod withdrawal.
The negative reactivity insertion resulting from the increase in reactor coolant temperature, as discussed in point 4 below, is not enough to counteract it.
- 4.
Ta,9 increases due to the large imbalance between nuclear power and turbine load, with nuclear power increasing rapidly. As the turbine load is essentially unchanging, energy must be added to the reactor coolant, increasing its temperature.
- 5.
The pressurizer level increase reflects the expansion in reactor coolant volume caused by the increase in coolant temperature.
- 6.
Charging flow decreases greatly with pressurizer level high relative to the level setpoint. Both the pressurizer level and the level setpoint (a function ofauctioneered high Tavg) are increasing, but the pressurizer level remains above the level setpoint.
- 7.
Pressurizer pressure increases as the pressurizer steam bubble is squeezed by the reactor coolant expansion. Pressurizer spray limits the pressure increase.
TRANSIENT 5.36 (CONT'D)
Transient 5.36 Guide Rev 0102 USNRC Technical Training Center 5.36-1
Westinghouse Technology Advanced Course Transient 5.36 Guide Point Explanation
- 8.
Steam pressure increases as heat transfer conditions in the SGs change due to the increased Tvg. dQ/dt = UA(Tavg - T,*); dQ/dt is essentially constant with the turbine control valve position unchanging, so T, (and Pt) is gradually increasing to maintain the same AT across the SG tubes.
- 9.
The steam dump demand increase indicates that the increase in nuclear power has driven T9 higher than Tf by > 5F, even though T,,f is much higher than its initial value. Note that at this time the dumps have not actuated, as there is no loss-of-load arming signal (no drop in turbine load).
- 10.
Bank D rod position decreases as the outputs of the temperature mismatch circuit (Tv, >
Tf) and power mismatch circuit (the large initial input from the failed transmitter has died off, and nuclear power has been increasing faster than turbine load for a fairly long period) call for rod insertion.
- 11.
TVg is decreasing as the rod insertion decreases nuclear power and narrows the primary-to secondary power mismatch. At steady-state (not yet reached at 4 min), nuclear power will have been made equal to turbine load, and the plant will be operating at - 50% power with the full-load programmed Tavg value. The new steady state will involve both a higher bank D rod position and a higher coolant temperature, with the associated reactivity changes canceling each other.
Note 1: The starting bank D rod position of 148 steps is not typical for a plant operating at 50%
power. The rods were initially diluted in to their starting positions so that the response to the failure would be more dramatic. Trojan's relaxed axial offset technical specification is not very restrictive on AFD, so starting with the bank D rods deeply inserted does not place the plant in an action statement. If this transient is started from the normal 100% conditions, the rods would be withdrawn to the 223-step auto withdrawal limit and then stop, and the slight change in reactivity would minimally affect other plant parameters, making for quite an uninteresting transient.
Note 2: The undershoot in pressurizer pressure during the second minute is caused by "overzealous" spraying. Tavg and pressurizer level are still increasing at this point, so steam bubble expansion cannot be contributing to the drop in pressure. (Info provided in case students ask.)
What this transient illustrates:
- 1. The responses of the rod control and steam dump control systems to a failed-high impulse pressure channel.
- 2. The increase in T vg when nuclear power > secondary load.
USNRC Technical Training Center 5.36-2 Rev 0102 I
USNRC Technical Training Center 5.36-2 Rey 0102
TRANSIENT 5.41 CONTROLLING PRESSURIZER PRESSURE CHANNEL FAILS HIGH Initial Conditions:
BOL Bank D Rod Position: 219 steps T.vg: 584.7'F Charging flow provided by one centrifugal charging pump Pressurizer Pressure: 2230 psig All control systems in automatic Nuclear Power: 100%
Initiating Event: Controlling pressurizer pressure channel (PT-455) fails high Point Explanation
- 1.
Actual pressurizer pressure trends down with maximum pressurizer spray. The pressurizer pressure control system is responding to a pressure input of 2500 psig (well above the pressure setpoint of 2235 psig) from the failed channel.
- 2.
The pressurizer level increase over the first - 2.5 min of the transient appears to be due primarily to reactor coolant expansion into the pressurizer resulting from the decreased density of the coolant caused by the pressure reduction. See the discussion which follows the point explanations for a more detailed explanation of this point. Also contributing to the indicated level increase is the fact that, at pressures lower than the 2235-psig setpoint, the indicated level overstates the actual level. See the attached figures for a more detailed explanation of this phenomenon. The corresponding decrease in charging flow over the same time interval is caused by pressurizer level exceeding the level setpoint (61.5%).
- 3.
Generator load decreases after 2 min due to an OTAT runback. The decreasing pressure on the three "good" channels is lowering the OTAT trip and runback setpoints.
- 4.
Bank D rod position and nuclear power decrease as the rod control system calls for inward rod motion in response to the turbine load decrease resulting from the runback (both the temperature mismatch and power mismatch circuits are calling for inward rod motion).
- 5.
The reactor trips (indicated by the step drop in bank D rod position) on OTAT. Pressurizer pressure is not low enough at the time of the trip to make low pressurizer pressure a plausible trip.
- 6.
The low pressurizer pressure ESF actuation setpoint is reached at - 2 min, 55 sec.
- 7.
Charging flow makes its characteristic response to an ESF actuation. The post-ESF charging flow value is relatively low because the pressurizer level is near the no-load setpoint and thus charging flow control valve FCV-121 is not wide open.
- 8.
Pressurizer level increases with ECCS flow and letdown isolation at the end of the transient.
TRANSIENT 5.41 (CONT'D)
Westinghouse Technology Advanced Course Transient 5.41 Guide USNRC Technical Training Center 5.41-1 Rev 0102
Detailed explanation for point 2:
At time 0, pressurizer pressure r 2235 psig, pressurizer level = 61.5%.
At time 2 min, 31 see (approximate end of level increase), pressurizer pressure r 1985 psig, pressurizer level = 65.2%.
Apparent increase in reactor coolant volume = (65.2 - 61.5%)(130 gal/% pzr lvl) = 481 gal.
From system description, RCS water volume at full power = 91,629 gal (includes 61.5% pressurizer level).
Specific volume of H20 at 585'F, 2235 psig = 0.02251 ft3/lbm (interpolated from subcooled H20 property tables).
Specific volume of H20 at 585'F, 1985 psig = 0.02263 fi3/lbm (interpolated from subcooled H20 property tables).
Assuming constant water mass, Vol. (end)
Vol.(start)
Spec. vol. (end)
Spec. vol. (start)
Calculated increase in reactor coolant volume
= Vol. (end) - Vol. (start);
= [Vol. (start)] x [Spec. vol. (end)] - Vol. (start);
[Spec. vu1. (start)]
=
(91, 629 gal) (0.02263 ft3/lbm) - '91,629 gal; (0.02251 ft/lbm)
= 488 gal.
Note the substantial agreement between the results of the two sets of calcukations The absolute closeness of the two results is a bit fortuitous. A difference of one unit in the last decimal place of either interpolated specific volume changes the final result by - 40 gal. Also, the calculated increase in coolant volume does not account for the fact that charging flow is less than letdown during the time interval of interest (a cumulative charging deficit of 40 gal over the first 2.5 min), or for the difference between indicated and actual levels when pressurizer pressure is different from the 2235-psig setpoint. The calculations are intended to show that the explanation for the observed parameter response is reasonable, not that the response is precisely predictable.
What this transient illustrates:
- 1. The response of the pressurizer pressure control system (maximum spray) to a failed-high controlling pressurizer pressure channel.
- 2. An increase in indicated pressurizer level with a decrease in coolant density.
- 3. An OTAT reactor trip.
- 4. A low pressurizer pressure ESF actuation.
USNRC Technical Training Center 5.41-2 Rev 0102 Westinghouse Technology Advanced Course Transient 5.41 Guide USNRC Technical Training Center 5.41-2 Rev 0102
Westinf~house Technology Advanced Course Taset54 ud TRANSIENT 5.42 CONTROLLING PRESSURIZER LEVEL CHANNEL FAILS LOW Initial Conditions:
BOL Bank D Rod Position: 219 steps Tavg: 585.1 'F Charging flow provided by one centrifugal charging pump Pressurizer Pressure: 2235 psig All control systems in automatic Nuclear Power: 100%
Initiating Event: Controlling pressurizer level channel (LT-459) fails low Point Explanation
- 1.
Charging flow increases to maximum as charging flow control valve FCV-121 opens fully.
The pressurizer level control system is responding to a level input of 0%, which is well below the level setpoint of 61.5%.
- 2.
Pressurizer level increases rapidly with maximum charging and no letdown (one letdown isolation valve and the previously open orifice isolation valve have been closed in response to the < 17% level of the failed channel).
- 3.
The reactor trip (as indicated by the step drop in bank D rod position) is caused by high pressurizer level (92%), as indicated by the 2 "good" level channels.
- 4.
Charging flow increases after the trip because plant pressure drops as T.,g decreases to < no load Ta.g. The operating charging pump's output increases when the discharge pressure drops (characteristic of centrifugal pump operation).
- 5.
Pressurizer level recovers after the trip due to (a) continued charging (at a high rate) and plant heatup and (b) continued charging alone after the plant heatup is stopped at no-load Tvg by steam dump operation (the end of the post-trip heatup accounts for the slope change in the pressurizer level recovery).
Letdown is still isolated. The pressurizer eventually fills completely.
- 6.
After-30 min, continued charging increases pressurizer pressure to the PORV lift setpoint, indicating that the plant is now solid. Note that the solid plant conditions are obtained several minutes after the indicated pressurizer level reaches 100%. At the low pressure (- 1860 psig for several minutes) and lower pressurizer water temperatures (pressurizer heaters have been turned off in response to the < 17% level of the failed channel) experienced during much of this transient, the indicated level overstates the actual level. See the attached figures for amore detailed explanation of this phenomenon. In addition, the pressurizer is not completely filled when the level reaches the upper taps of the level detectors.
- 7.
Charging flow decreases after 30 min as plant pressure increases and charging pump output decreases.
TRANSIENT 5.42 (CONT'D)
USNRC Technical Training Center 5.42-1 Rev (J1UZ USNRC Technical Training Center 5.42-1 Transient 5.42 Guide S.......
I.............
DI............
Rey 0102
Point Explanation
- 8.
The pressurizer pressure and charging flow "squiggles" between 32 and 36 min indicate PORV lifts.
- 9.
VCT level drops during the interval of 0 - 19 min because maximum charging and isolated letdown are depleting the VCT inventory. The change in slope at - 3 min indicates initiation of automatic makeup, which slows but does not stop the VCT level decrease.
Also, there is a less-than-obvious increase in the rate of VCT inventory depletion shortly after 14 min which reflects the increase in charging flow at that time.
- 10.
VCT level recovers after 19 min with continued automatic makeup and seal return because the VCT outlet valves have shut on low VCT level (the charging pump suctions are now supplied by the RWST). The change in slope in the VCT level increase at - 24 min indicates the cutoff of automatic makeup; the level continues to increase with seal return alone. (If seal return were supplied to the suction of the charging pumps, then recovery of the VCT would end with the cutoff of automatic makeup.)
What this transient illustrates:
- 1. The response of the pressurizer level control system (maximum charging) to a failed-low controlling pressurizer level channel.
- 2. A high pressurizer level reactor trip.
- 3. The depletion and recovery of VCT level.
- 4. The development of solid plant conditions due to overfilling of the RCS.
USNRC Technical Training Center 5.42-2 Rev 0102 Westinghouse Technologv Advanced Course Transient 5.42 Guide USNRC Technical Training Center 5.42-2 Rev 0102
TRANSIENT 5.43 CONTROLLING PRESSURIZER PRESSURE CHANNEL FAILS LOW Initial Conditions:
BOL Bank D Rod Position: 219 steps Tavg. 585.1 OF Charging flow provided by one centrifugal charging pump Pressurizer Pressure: 2235 psig All control systems in automatic Nuclear Power: 100%
Initiating Event: Controlling pressurizer pressure channel (PT-455) fails low Point Explanation
- 1.
Actual pressurizer pressure trends up with maximum heater output from both variable and backup heaters. The pressurizer pressure control system is responding to a pressure input of 1700 psig (well below the pressure setpoint of 2235 psig) from the failed channel.
- 2.
On five different occasions, the pressurizer pressure increases to the PORV lift setpoint.
Only PORV PCV-456 lifts; the 2-out-of-2 coincidence for PCV-455A cannot be met with one of its inputs (pressure channel 455) failed low. With each PORV lift, pressure drops about 40 psig, the PORV recloses in a few seconds, and the upward trend in pressure resumes with maximum heater output.
- 3.
The decrease in pressurizer level reflects the increasing reactor coolant density associated with the increasing pressure. Recall the detailed explanation for the trend in pressurizer level in transient 5.41 (Controlling Pressurizer Pressure Channel Fails High). In that transient, pressurizer level increases with a decrease in pressure and corresponding decrease in coolant density. In this transient, pressurizer level decreases with an increase in pressure and corresponding increase in coolant density. Also contributing to the indicated level decrease is the fact that, at pressures higher than the 223 5-psig setpoint, the indicated level understates the actual level.
- 4.
The five short-term increases ("blips") in pressurizer level are coincident with the PORV lifts.
Each PORV lift results in a decrease in reactor coolant density and corresponding increase in pressurizer level.
What this transient illustrates:
- 1. The response of the pressurizer pressure control system (maximum heaters) to a failed-low controlling pressurizer pressure channel.
- 2. The responses of pressurizer pressure, pressurizer level, and charging flow to several PORV lifts.
USNRC Technical Training Center 5.43-1 Rev 0102 5.43-1 Westinghouse Technology Advanced Course Transient 5.43 Guide Rev 0102 USNRC Technical Training Center
TRANSIENT 5.51 CONTROLLING STEAM GENERATOR LEVEL CHANNEL FAILS LOW Initial Conditions:
BOL Tavg: 58 5.1 F Pressurizer Pressure: 2235 psig Nuclear Power: 100%
Bank D Rod Position: 219 steps Charging flow provided by one centrifugal charging pump All control systems in automatic Initiating Event: Controlling SG #1 level channel (LT-519) fails low Point Explanation
- 1.
Feed flow to SG #1 increases to maximum as the main feed regulating valve opens in response to the controlling level input falling well below the 44% level setpoint.
- 2.
Steam generator level in SG #1 increases rapidly with the feed flow increase and no change in steam flow.
- 3.
The turbine trip (as indicated by the step drop in generator load) is caused by high steam generator water level (the level measured by the two "good" level detectors on SG #1 reaches the 69% level turbine trip setpoint).
- 4.
The reactor trip (as indicated by the step drop in bank D rod position) is caused by the turbine trip with plant power above the P-7 setpoint.
What this transient illustrates:
- 1. The response of the steam generator water level control system (maximum feed regulating valve position) to a failed-low controlling steam generator level channel.
- 2. A turbine trip on high SG level.
- 3. A reactor trip on a turbine trip + P-7.
USNRC Technical Training Center 5.51-I Rev 01112 USNRC Technical Training Center Transient 5.51 Guide 5.51-1 Rev 0102
Westinphouse Technoloffv Advanced Course Taset55 ud TRANSIENT 5.52 CONTROLLING STEAM GENERATOR LEVEL CHANNEL FAILS HIGH Initial Conditions:
BOL Tavg:585.1 0F Pressurizer Pressure: 2235 psig Nuclear Power: 100%
Bank D Rod Position: 219 steps Charging flow provided by one centrifugal charging pump All control systems in automatic Initiating Event: Controlling SG #1 level channel (LT-519) fails high Point Explanation
- 1.
Feed flow to SG #1 decreases to minimum as the main feed regulating valve closes in response to the controlling level input rising well above the 44% level setpoint.
- 2.
Steam generator level in SG #1 decreases rapidly with the feed flow decrease and no change in steam flow.
- 3.
The reactor trips (as indicated by the step drop in bank D rod position) on low steam generator water level (25.5%, as measured by the two "good" SG #1 level channels) and steam flow/feed flow mismatch.
What this transient illustrates:
- 1. The response of the steam generator water level control system (minimum feed regulating valve position) to a failed-high controlling steam generator level channel.
- 2. A reactor trip on low SG level + steam flow/feed flow mismatch.
USNRC Technical Training Center 5.52-1 Key uiu
5.52-1 USNRC Technical Training Center Transient 5.52 Guide R~ev 0102
TRANSIENT 5.53 CONTROLLING STEAM GENERATOR FEED FLOW CHANNEL FAILS LOW Initial Conditions:
BOL Bank D Rod Position: 219 steps "TIvg: 585.1 TF Charging flow provided by one centrifugal charging pump Pressurizer Pressure: 2235 psig All control systems in automatic Nuclear Power: 100%
Initiating Event: Controlling SG #1 feed flow channel (FT-510) fails low Point Explanation
- 1.
Feed flow to SG #1 increases to maximum as the main feed regulating valve opens in response to the large steam flow/feed flow mismatch (feed flow < steam flow) input to the steam generator water level control system.
- 2.
Steam generator level in SG #1 increases with the feed flow increase and no change in steam flow. Even after feed flow begins to decrease (as explained in point 3 below), steam generator level continues to rise as long as feed flow exceeds steam flow.
- 3.
The large (integrated) level error causes feed flow to SG #1 to decrease, overriding the still present steam flow/feed flow mismatch. This trend in feed flow illustrates that steam generator water level control is level dominant.
- 4.
Steam generator level in SG #1 decreases with feed flow less than steam flow. The level error input to steam generator water level control brings level back to setpoint (44%).
- 5.
Steam generator level in SG #1 remains constant at setpoint over the final 10 min of the transient. The integrated level error from the first 10 min of the transient (level > setpoint) counteracts the steam flow/feed flow mismatch (controlling feed flow channel still failed low) during this interval.
What this transient illustrates:
- 1. The response of the steam generator water level control system to a failed-low controlling steam generator feed flow channel.
- 2. That steam generator water level control is a level-dominant system.
USNRC Technical Training Center 5.53-1 Rev 0102 5.53-1 Transient 5.53 Guide Rev 0102 USNRC Technical Training Center
TRANSIENT 5.54 CONTROLLING STEAM GENERATOR FEED FLOW CHANNEL FAILS HIGH Initial Conditions:
BOL Bank D Rod Position: 219 steps Tavg: 585.1 OF Charging flow provided by one centrifugal charging pump Pressurizer Pressure: 2235 psig All control systems in automatic Nuclear Power: 100%
Initiating Event: Controlling SG #1 feed flow channel (FT-510) fails high Point Explanation
- 1.
Feed flow to SG #1 decreases as the main feed regulating valve closes in response to thelarge steam flow/feed flow mismatch (feed flow > steam flow) input to the steam generator water level control system.
- 2.
Steam generator level in SG #1 decreases with the feed flow decrease and no change in steam flow. The change in SG level in this transient is not as great as that seen in transient 5.53, as the flow error input to the water level control system is not as large. (Feed flow failing high goes from 3.7 X 106 lbm/hr to 5 X1 06 lbm/hr; feed flow failing low goes from 3.7 X 106 lbm/hr to 0.) Even after feed flow begins to increase (as explained in point 3 below), steam generator level continues to drop as long as steam flow exceeds feed flow.
- 3.
The (integrated) level error causes feed flow to SG #1 to increase, overriding the still-present steam flow/feed flow mismatch. This trend in feed flow illustrates that steam generator water level control is level dominant.
- 4.
Steam generator level in SG #1 increases with feed flow greater than steam flow. The level error input to steam generator water level control brings level back to setpoint (44%).
- 5.
Steam generator level in SG #1 remains constant at setpoint over the final few minutes of the transient. The integrated level error from the first several minutes of the transient (level <
setpoint) counteracts the steam flow/feed flow mismatch (controlling feed flow channel still failed high) during this interval.
What this transient illustrates:
- 1. The response of the steam generator water level control system to a failed-high controlling steam generator feed flow channel.
- 2. That steam generator water level control is a level-dominant system.
USNRC Technical Training Center 5.54-1 Rev 0102 Westinghouse Technology Advanced Course Transient 5.54 Guide USNRC Technical Training Center 5.54-1 Rev 0102
TRANSIENT 5.61 TRIP OF #1 MAIN FEED PUMP Initial Conditions:
BOL Bank D Rod Position: 219 steps T.,g: 585.1 *F Charging flow provided by one centrifugal charging pump Pressurizer Pressure: 2235 psig All control systems in automatic Nuclear Power: 100%
Initiating Event: #1 main feed pump trips Point Explanation
- 1.
- 1 MFP flow rate decreases to 0 with the trip of the pump.
- 2.
- 2 MFP flow rate increases to compensate for the tripped pump. With the loss of discharge pressure from the #1 pump, the AP across the main feed regulating valves decreases, and the feed pump speed control system increases the speed of the still operating pump to boost feedwater pressure and regulating valve AP.
- 3.
Generator load decreases rapidly to less than 60% on the loss-of-feed-pump turbine setback.
The setback feature of the turbine EHC system reduces load at 2%/sec by rapidly reducing the input to the load limit circuit.
- 4.
Bank D rod position decreases at the maximum rate (72 steps/min) in response to the power mismatch circuit (turbine load decreasing rapidly) and temperature mismatch circuit (Tf <
Tavg) of the rod control system.
- 5.
Nuclear power decreases in response to the negative reactivity added by rod insertion and, to a small extent, by the increase in Tavg.
- 6.
Steam dump demand increases to a large value with the drop in T1.f accompanying the turbine setback and the increase in Tavg resulting from the power mismatch (nuclear power > secondary load).
- 7.
Steam flow decreases in response to the closure of the turbine control valves resulting from the setback, then increases with steam dump actuation. The steam dumps are armed by the setback-induced rapid load reduction, and a large demand exists, as described in point 6 above.
The steam dump demand and arming signal exist for several seconds prior to the increase in steam flow at - 36 sec; before this time steam dump operation is masked by the rapid control valve closure.
- 8.
Steam dump demand decreases, first rapidly and then steadily, as rod insertion brings Tavg down to T~r TRANSIENT 5.61 (CONT'D)
Point Explanation USNRC Technical Training Center 5.61-1 Rev 0102 5.61-1 Transient 5.61 Guide Rey 0102 USNRC Technical Training Center
- 9.
The change in bank D rod position slows as the inputs to the rod control system from the temperature and power mismatch circuits almost cancel. Tavg is > Tef, so the temperature mismatch circuit is calling for rod insertion, but nuclear power has been decreasing with turbine load constant, so the power mismatch circuit is calling for rod withdrawal.
What this transient illustrates:
- 1. A loss-of-feed-pump turbine setback.
- 2. Steam dump actuation to handle the difference between nuclear power and secondary load.
USNRC Technical Training Center 5.61-2 Rev 0102 Westinehouse Technoloe" Advanced Course Transient 5.61 Guide USNRC Technical Training Center 5.61-2 Rev 0102
Westiniyhouse Technolo~yv Advanced Course Taset56 ud TRANSIENT 5.62 INADVERTENT MSIV CLOSURE Initial Conditions:
BOL Bank D Rod Position: 194 steps Tayg: 567'1F Charging flow provided by one centrifugal charging pump Pressurizer Pressure: 2235 psig All control systems in automatic Nuclear Power: 50%
Initiating Event: The MSIV in the main steam line from the
- 1 SG inadvertently shuts Point Explanation
- 1.
Steam flow from the #1 SG rapidly decreases to near 0 as the MSIV shuts. The MSIV closes in about 2 sec.
- 2.
Steam generator level in the #1 SG shrinks rapidly in response to the large reduction in steam demand from that SG with the MSIV closure.
- 3.
Feed flow to the #1 SG rapidly decreases as the #1 SG water level control system responds to the rapid drop in steam flow by closing the #1 SG main feedwater regulating valve.
- 4.
Steam pressure in the #1 main steam line increases rapidly, as steam is bottled up in the #1 SG and its associated main steam line.
- 5.
The removal of flow resistance associated with the isolation of the #1 main steam line causes steam flow from the #4 SG (as well as from the #2 and #3 SGs) to increase.
- 6.
Steam generator level in the #4 SG (as well as in the #2 and #3 SGs) swells in response to the increase in steam demand from that SG.
- 7.
Feed flow to the #4 SG (as well as to the #2 and #3 SGs) increases as the #4 SG water level control system responds to the increase in steam flow by opening the #4 SG main feedwater regulating valve.
- 8.
Steam pressure in the #4 main steam line (as well as in the #2 and #3 main steam lines) decreases in response to the increased heat transfer in (and increased steaming from) that SG.
The 3 unaffected SGs are attempting to maintain the turbine load at the original level and cannot support the necessary steam flow at the original steam pressure.
- 9.
The reactor trips (as indicated by the step drop in bank D rod position) on low-low steam generator water level in the #1 SG. The level shrink and reduction in feed flow quickly drop the water level off-scale low in that SG.
TRANSIENT 5.62 (CONT'D)
USNRC Technical Training Center Transient 5.62 Guide 5.62-1 Rev 0102
Westinehouse Technoloev Advanced Course Taset56 ud What this transient illustrates:
- 1. The effects of a closed MSIV: reduced steam flow, SG level shrink, increased steam pressure.
- 2. Increased steam flow from the other 3 main steam lines to "pick up the slack."
USNRC Technical Training Center 5.62-2 Rev 0hZ USNRC Technical Training Center Transient 5.62 Guide 5.62-2 Rev 0102
Westinghouse Technolony Advanced Course Transient 5.63 Guide TRANSIENT 5.63 RCP TRIP Initial Conditions:
BOL T.,g: 563.2°F Pressurizer Pressure: 2235 psig Nuclear Power: 28%
Bank D rod position: 178 steps Charging flow provided by one centrifugal charging pump Feed reg. valve for SG #1 is in manual and maintaining -60%
level initially; it is placed in auto after the SG level reaches its minimum value as a result of the initial shrink All other control systems in automatic Initiating Event:-The RCP in loop #1 trips Point Explanation
- 1.
RCS -flow in loop #1 decreases to 0 as the reactor coolant pump coasts down with flywheel inertia.
- 2.
RCS flow in loop #4 (as well as in loops #2 and #3) increases with the decrease in flow resistance from loop #1 and the development of reverse flow in that loop supplied by the discharge of the 3 running pumps.
- 3.
The reduction in steam flow in steam line #1 reflects the degradation of heat transfer in SG
- 1. The reduction of the reactor coolant flow rate in the tubes of that SG reduces the heat transfer coefficient for primary-to-secondary heat transfer, thereby reducing the boiling rate, and steam flow drops rapidly.
- 4.
The relative absence of boiling in SG #1 and its associated flow resistance allows feedwater to flow into the tube bundle region from the downcomer (where SG level is measured), and the drop in steam generator level in the #1 SG results. Contributing to the level drop is the reduction in recirculation flow from the moisture separators to the downcomer with the reduction in steam flow. Note: the manual manipulation of SG level prior to the initiation of the transient prevents a reactor trip on low-low SG level.
- 5.
The increase in RCS flow in loop #1 reflects the development of reverse flow in that loop.
Discharge from the 3 running pumps is supplied to the cold leg of the idle loop via the reactor vessel annulus.
TRANSIENT 5.63 (CONT'D)
USNRC Technical Training Center 5.63-1 Rev 0102 Wlestinahouse Technoloav Advanced Course Transient 5.63 Guide USNRC Technical Training Center 5.63-1 Rev 0102
Westinehouse Technoloi~v Advanced Course Taset56 ud Point Explanation
- 6.
The decreased value of loop #1 T.vg that exists at the end of the 4 plotted minutes also reflects the development of reverse flow in that loop. Once reverse flow in the idle loop is fully developed, the flow in that loop enters the SG (from the cold leg) with a temperature
- equal to the T, of the other 3 loops and exits (to the hot leg) a little colder. At this point, the greatly reduced flow and altered pressure drops in loop #1 mean that the actual loop conditions are transmitted to the bypass manifold RTDs with a much greater time lag and that the calculated Tavg may not be a true average loop temperature. However, the time span denoted by this point is a fairly long time after the development of reverse flow, and the actual loop #1 T. and T. differ by only a.few degrees because of the minimal heat transfer in that loop's SG, so the indicated T8,,g at the end of the 4 minutes should be very close to the transient endpoint T.,g in this loop.
- 7.
Steam flow in steam line #4 (as well as in steam lines #2 and #3) increases as heat transfer in the SGs in the loops with the running RCPs increases to maintain the unchanged turbine load. The increased steam flow is supported by a core AT which is a few degrees larger than its initial value now that the core mass flow rate has decreased to - 3/4 of its initial value (dQ/dt = dm/dt [TB - TJ).
What this transient illustrates:
- 1. The reduction in RCS loop flow associated with an RCP trip and the subsequent development of reverse flow in that loop.
USNRC Technical Training Center 5.63-2 Rev U1IJZ USNRC Technical Training Center Transient 5.63 Guide 5.63-2 Rev 0102
Westinghouse Technolo~yv Advanced Course Taset57 ud TRANSIENT 5.71 SG SAFETY VALVE FAILS OPEN Initial Conditions:
BOL Bank D Rod Position: 103 steps Tvg: 558.2°F Charging flow provided by one centrifugal charging pump Pressurizer Pressure: 2233 psig Normal plant configuration for startup Nuclear Power: ~108 amps in I.R.
Initiating Event: One safety valve on main steam line #1 fails to 100% open Point Explanation
- 1.
Steam flow in main steam line #1 increases to the safety valve capacity for no-load steam pressure.
- 2.
Steam generator level in SG #1 swells with the surge in steam demand associated with the safety valve failing open.
- 3.
Steam pressure in main steam line #1 decreases as the failed safety valve discharges to the atmosphere.
- 4.
Tavg decreases due to the cooldown of the reactor coolant caused by the additional steaming through the safety valve.
- 5.
Steam pressure in main steam line #4 (as well as the other intact main steam lines) decreases but lags the steam pressure in main steam line #1. The other three main steam lines cannot feed the failed-open safety valve because the check valve in main steam line #1 prevents backflow, but the cooldown of the reactor coolant (see explanation for point 4 above) is reducing the steam pressures in the intact steam lines.
- 6.
Intermediate range power increases in response to the positive reactivity insertion associated with the decrease in reactor coolant temperature. The increase is rather small: 2.47 X 10.
amps to 2.71 X 10"8 amps.
- 7.
The reactor trip (indicated by the step drop in bank D rod position) and ESF actuation (indicated by the characteristic perturbation in charging flow) is caused by high steam line AP.
At -19 sec, the AP between steam line #1 and at least two of the other steam lines has reached the 100 psi setpoint.
- 8.
The decrease in steam generator level in SG #1 reflects dissipation of that SG's inventory through the failed-open safety valve.
TRANSIENT 5.71 (CONT'D)
Point Explanation USNRC Technical Training Center 5.71-I xev uiui 5.71-1 Rev 0202 Transient 5.71 Guide S
g7.........
USNRC Technical Training Center
- 9.
Feed flow during the latter few minutes of the transient reflects AFW system operation. The AFW system actuation is caused by the ESF actuation. The AFW flow to SG #1 is a little larger than that to the other 3 SGs because of the lower pressure in SG #1.
What this transient illustrates:
- 1. The relatively slow dissipation of one SG's inventory through a failed-open safety valve.
- 2. The isolation of the steam break from the other 3 SGs by the faulted SG's check valve.
- 3. A steam-break-induced cooldown of the RCS.
- 4. An increase in reactivity associated with a decrease in RCS temperature.
USNRC Technical Training Center 5.71-2 Rev 0202 Transient 5.71 Guide USNRC Technical Training Center 5.71-2 Rev 0202
TRANSIENT 5.72 LARGE STEAM BREAK INSIDE CONTAINMENT WITH LOOP, 10-8 AMPS IN I.R.
Initial Conditions:
BOL Charging flow provided by one centrifugal charging pump Tvg: 558.2"F Normal plant configuration for startup Pressurizer Pressure: 2232 psig Initiating Event: Large break on main steam line #1 (8.72 X Nuclear Power: -1 0' amps in I.R.
106 lbm/hr) and LOOP occur simul Bank D Rod Position: 103 steps taneously at -5 sec.
Point Explanation
- 1.
Steam flow in main steam line #1 increases off-scale high with the steam break.
- 2.
Steam generator level in SG #1 swells off-scale high with the surge in steam demand associated with the steam break.
- 3.
Steam pressure in main steam line #1 decreases as steam is discharged to the containment atmosphere.
- 4.
Steam pressure in main steam line #4 (as well as the other intact main steam lines) remains at or near its initial value. The other three main steam lines cannot feed the break because the check valve in main steam line #1 prevents backflow.
- 5.
Tvg decreases due to the cooldown of the reactor coolant caused by the additional steaming through the break.
- 6.
Charging flow decreases to 0 very rapidly with the LOOP; the CCP which has been operating is now unpowered.
- 7.
The reactor trip (indicated by the step drop in bank D rod position) is caused by the LOOP, which interrupts nonvital power to the rod drive coils. All stationary grippers "let go," and all control rods fall into the core.
- 8.
Charging flow returns after the emergency diesel generators have started and attained rated speed, the EDG output breakers have closed, and the CCPs have restarted. The CCPs are the first pieces of emergency equipment to be started by the DBA sequencer, which is initiated by a high steam line AP ESF actuation. (The AP between steam line #1 and at least two of the other steam lines reaches the 100 psi setpoint about 3 sec after the start of the accident.) The CCPs are now operating in the HPI mode; the plotted charging flow reflects seal injection to the RCPs (normal charging is isolated) and a constant charging flow control valve position (see the note below).
TRANSIENT 5.72 (CONT'D)
USNRC Technical Training Center Westinghouse Technoloev Advanced Course 5.72-1 Rev 0102
Point Explanation
- 9.
Feed flow to SG #1 increases with actuation of the AFW system (the AFW system is actuated by the ESF actuation). The flow to that SG is initially higher than that to the other three SGs because of its lower pressure. The AFW flow to SG #1 then decreases when each AFW flow control valve to that SG closes in response to the high flow (> 500 gpm) sensed in its supply line. The train B flow control valve closes before the train A valve does, hence the "step-down" nature of the AFW flow reduction.
- 10.
The decrease in steam flow in main steam line #1 reflects the decrease in driving force for steam flow with the reduction in steam pressure in that steam line and the increase in containment pressure.
- 11.
The decrease in steam generator level in SG #1 reflects the rapid dissipation of that SG's inventory through the steam break.
- 12.
Containment pressure increases as steam is discharged from main steam line #1 to the containment atmosphere. The pressure increase is tempered by containment fan cooler operation.
Note : The slowly increasing post-ESF charging flow illustrates the reaction of many plant controllers to a loss of power. These controllers revert to manual and maintain the last auto demands called for when non-vital power is lost. Thus, the controller for the charging flow control valve (FCV-121) holds the valve at the last automatically demanded position; the slowly increasing charging flow reflects the slowly decreasing RCS pressure. With power available, the FCV-121 controller responds to pressurizer level errors, and sharply increasing charging flow would be expected in this case. (Info provided in case students ask.)
What this transient illustrates:
- 2. The isolation of the steam break from the other 3 SGs by the faulted SG's check valve.
- 3. A steam-break-induced cooldown of the RCS.
- 5. LOOP-induced effects: the delay in starting the charging pumps after the ESF actuation and the controller responses.
- 6. The "feed-only-good-generator" feature of the AFW flow control valves.
USNRC Technical Training Center 5.72-2 Rev 0102 Rev 0102 Westingyhouse Technoloffv Advanced Course USNRC Technical Training Center 5.72-2
TRANSIENT 5.73 LARGE STEAM BREAK INSIDE CONTAINMENT, 100% POWER Initial Conditions:
BOL Bank D Rod Position: 219 steps Tavg: 558.2'F Charging flow provided by one centrifugal charging pump Pressurizer Pressure: 2230 psig All control systems in automatic Nuclear Power: 100%
Initiating Event: Large break on main steam line #1 (8.72 X 106 lbm/hr) inside containment Point Explanation
- 1.
Steam flow in main steam line #1 increases off-scale high with the steam break.
- 2.
Steam generator level in SG #1 swells with the surge in steam demand associated with the steam break.
- 3.
Steam pressure in main steam line #1 decreases as steam is discharged to the containment atmosphere.
- 4.
The removal of flow resistance associated with the isolation of the #1 main steam line (because of closure of its check valve) causes steam flow from the #4 SG (as well as from the #2 and
- 3 SGs) to increase.
- 5.
The reactor trip (indicated by the step drop in bank D rod position) and ESF actuation (indicated by the characteristic perturbation in charging flow) is caused by high steam flow plus low steam pressure. The high steam flow setpoint is exceeded with the break in steam line
- 1 and the increased flow in the other 3 steam lines (see the explanation for point 4 above), and the low steam pressure setpoint is reached as the steam pressure decreases in all steam lines.
Note that the ESF actuation takes place when the steam pressure is - 750 psig in the intact steam lines* the input to the low steam pressure bistable reaches the low steam pressure setpoint before actual pressure does because of the lead-lag circuit through which the steam pressure signal is processed. Note also that the other ESF actuation signals are not possible:
pressurizer pressure and Tag are not low enough yet, and steam line AP and containment pressure are not large enough yet. However, one other reactor trip signal is possible: a turbine trip + P-7, with the turbine tripping on high SG level.
- 6.
The closure of the steam line check valves and MSIVs allows steam pressure in main steam line #4 (as well as in steam lines #2 and #3) to recover following the reactor trip and ESF actuation.
- 7.
Tvg decreases due to the cooldown of the reactor coolant caused by the steam release through the break. Note that the cooldown in RCS loop #1 (which contains the SG which is feeding the break) leads the cooldowns in the other loops.
TRANSIENT 5.73 (CONT'D)
Westinahouse Technoloay Advanced Course Transient 5.73 Guide Rev 0102 USNRC Technical Training Center 5.73-1
Westinf~house Technology Advanced Course Taset57 ud Point Explanation
- 8.
Feed flow to SG #1 increases with actuation of the AFW system (the AFW system is actuated by the ESF actuation). The flow to that SG is initially higher than that to the other three SGs because of its lower pressure. The AFW flow to SG #1 decreases to 0 in two steps when each AFW flow control valve to that SG closes in response to the high flow (>
500 gpm) sensed in its supply line to that SG. The two steps are due to the train A and train B valves closing at different times.
- 9.
The decrease in steam flow in main steam line #1 and in steam break flow reflects the decrease in driving force for steam flow with the reduction in steam pressure in that steam line and the increase in containment pressure.
- 10.
The decrease in steam generator level in SG #1 reflects the rapid dissipation of that SG's inventory through the steam break.
- 11.
Containment pressure increases as steam is discharged from main steam line #1 to the containment atmosphere. The pressure increase is tempered by containment fan cooler operation.
Note: The "blip" in generator load at - 50 sec reflects the voltage/current spike accompanying the opening of the output breakers.
What this transient illustrates:
- 2. The isolation of the steam break from the other 3 SGs by the faulted SG's check valve and by MSIV closure.
- 3. A steam-break-induced cooldown of the RCS.
- 4. A high steam flow + low steam pressure ESF actuation and the characteristic response of charging flow.
- 5. The "feed-only-good-generator" feature of the AFW flow control valves.
USNRC Technical Training Center 5.73-2 Rev 1)11)1 USNRC Technical Training Center Transient 5.73 Guide 5.73 -2 Rey 010L
Westinl1house Tftchnnolow Advanced Course Transient 5.74 Guide TRANSIENT 5.74 LARGE STEAM BREAK DOWNSTREAM OF MSIVs, 10"8 AMPS IN I.R.
Initial Conditions:
BOL Bank D Rod Position: 103 steps Tayg: 558.27F Charging flow provided by one centrifugal charging pump Pressurizer Pressure: 2232 psig Normal plant configuration for startup Nuclear Power: 8 amps in I.R.
Initiating Event: Large break (8.72 X 106 ibm/hr) downstream of the MSIVs Point Explanation
- 1.
Steam flow (all main steam lines) increases rapidly with the steam break.
- 2.
Steam pressure decreases with the unrestricted steam flow through the break.
- 3.
The reactor trip (indicated by the step drop in bank D rod position) is caused by an ESF actuation on high steam flow plus low steam pressure. The high steam flow setpoint is reached with the increase in steam flow through the break (the high steam flow setpoint is at its minimum value with no turbine load), and the low steam pressure setpoint is reached as the steam pressure constantly decreases. Note that the ESF actuation takes place when the steam pressure is - 980 psig; the input to the low steam pressure bistable reaches the low steam pressure setpoint before actual pressure does because of the lead-lag circuit through which the steam pressure signal is processed. Note also that the other ESF actuation signals are not possible: pressurizer pressure and Tavg are not low enough yet, and, because the break is downstream of the MSIVs, there is no steam line AP, and it does not cause containment pressure to increase.
- 4.
The charging flow perturbation reflects the ESF actuation (isolation of normal charging and diversion of some HPI flow through the seal injection lines).
- 5.
The additional steam flow through the break cools the reactor coolant; the pressurizer level decrease reflects the reduction in reactor coolant volume caused by the decrease in coolant temperature.
- 6.
Steam flow decreases to 0, reflecting the MSIV closure associated with the high steam flow ESF actuation.
- 7.
Source range power comes on scale when both source range detectors are energized by both I.R. channels reaching the P-6 setpoint (10-l0 amps) following the trip.
- 8.
Pressurizer level increases with injection from the CCPs and letdown isolated following the ESF actuation.
TRANSIENT 5.74 (CONT'D)
USNRC Technical Training Center 5.74-1 Rev 0102 USNRC Technical Training Center 5.74-1 Rev 0102
Westnghuse echoloa Adance CorseTransient 5.74 Guide What this transient illustrates:
- 2. A high steam flow + low steam pressure ESF actuation and the isolation of all main steam lines.
- 3. A steam-break-induced cooldown of the RCS.
- 4. The energizing of the source range detectors when intermediate range power reaches the P-6 setpoint.
USNRC Technical Training Center 5.74-2 Rev 0102 Rev 0102 USNRC Technical Training Center Westin~house Technolo*v Advanced Course 5.74-2
Westingyhouse Technolozv Advanced Course Taset57 ud TRANSIENT 5.75 SGTR IN SG #1 Initial Conditions:
BOL Charging flow provided by one centrifugal charging pump Tavg: 585.3 *F All control systems in automatic Pressurizer Pressure: 2230 psig Initiating Event: 700-gpm tube rupture in SG #1 (-1.75 times Nuclear Power: 100%
the leak flow through 1 tube, per the Bank D Rod Position: 219 steps simulator malfunction)
Point Explanation
- 1.
Pressurizer level drops with the loss of coolant inventory from the RCS.
- 2.
Pressurizer pressure decreases with the expansion of the pressurizer steam bubble associated with the inventory loss.
- 3.
Charging flow increases to a very high value as the pressurizer level control system opens charging flow control valve FCV-121 in response to the low level, and the discharge flow from the operating CCP is enhanced by the low RCS pressure.
- 4.
Steam generator level in SG #1 increases by a few percent with the leakage of reactor coolant into that SG. The level is brought back to setpoint as the level error input to the SG water level control system reduces feed flow to SG #1 (see point 5 below).
- 5.
Feed flow to SG #1 decreases in response to the level error input to the SG water level control system.
- 6.
Generator load decreases in response to OTAT runbacks. The OTAT runback sepoint is greatly reduced by the decrease in pressurizer pressure. A close inspection of the plot reveals 3 separate runbacks.
In the turbine EHC system each runback is accomplished by the reduction of the load demand by - 5% in a 2.3-sec interval; runbacks continue every 30 sec as long as the runback condition persists.
- 7.
The reactor trips (indicated by the step drop in bank D rod position) on low pressurizer pressure (the setpoint is 1865 psig).
- 8.
The low pressurizer pressure (1 807-psig setpoint) ESF actuation (as indicated by the perturbation in charging flow) occurs a few seconds after the reactor trip. The shift in the charging flow value is exaggerated because the beginning and ending charging flows are so high due to the large charging demand (FCV-121 is wide open) and low RCS pressure.
TRANSIENT 5.75 (CONT'D)
Rev 0102 Transient 5.75 Guide USNRC Technical Training Center 5.75-1
Mestinghouse Technologv Advanced Course Taset57 ud Point Explanation
- 9.
Pressurizer pressure decreases even faster after the pressurizer empties. With the steam bubble/coolant interface now in the surge line, the surface area available for evaporation is greatly reduced, and the rate of pressure decrease is now hardly affected by evaporation at the interface. Also contributing to the pressure drop at this point are the continued inventory loss and coolant volume contraction as T.,g is brought to the no-load value. The minimum pressure reached is - 1090 psig.
- 10.
Pressurizer pressure recovers after about 10 min as total ECCS flow from the CCPs and the safety injection pumps exceeds the flow through the tube rupture. The decrease in RCS pressure has both increased injection flow and reduced the driving force for tube leakage.
Existing steam bubbles in the RCS are being squeezed.
- 11.
The increase in pressurizer level reflects the recovery of coolant inventory with ECCS flow > tube leakage.
- 12.
Steam generator level in SG #1 comes back on scale first because it is filling with AFW flow and reactor coolant leakage, while the other 3 SGs are filling with AFW flow alone.
(All SG level indications had gone off-scale low due to post-trip shrinks.)
What this transient illustrates:
- 1. The loss of inventory from the RCS and the reduction in RCS pressure associated with an SGTR, and the resulting protection system responses.
- 2. A low pressurizer pressure ESF actuation and the characteristic response of charging flow.
- 3. OTAT runbacks.
- 4. The development of saturated conditions in the RCS.
USNRC Technical Training Center 5.75-2 Rev O1UZ Rev 0102 Transient 5.75 Guide S.....
h v USNRC Technical Training Center 5.75-2
Westin ihouse Technolofv Advanced Course Taset57 ud TRANSIENT 5.76 6-IN. COLD-LEG BREAK Initial Conditions:
BOL Bank D Rod Position: 219 steps Tayg: 585.2°F Charging flow provided by one centrifugal charging pump Pressurizer Pressure: 2232 psig All control systems in automatic Nuclear Power: 100%
Initiating Event: 40,000-gpm (-6-in. diameter) break in cold leg of loop #1 Point Explanation
- 1.
Pressurizer level drops rapidly with the loss of coolant inventory from the RCS.
- 2.
Pressurizer pressure decreases rapidly with the expansion ofthe pressurizer steam bubble and then complete emptying of the pressurizer.
- 3.
The reactor trips (indicated by the step drop in bank D rod position) on low pressurizer pressure (the setpoint is 1865 psig).
- 4.
The low pressurizer pressure (the setpoint is 1807 psig) ESF actuation (as indicated by the perturbation in charging flow) occurs immediately after the reactor trip. The shift in the charging flow value is exaggerated because the beginning and ending charging flows are so high due to the large charging demand (FCV-121 is wide open) and low RCS pressure.
- 5.
Pressurizer pressure "hangs up" at - 940 psig. The saturation temperature for this pressure is-540'F; a great deal, if not all, of the reactor coolant has reached saturation. This means that flashing is occurring at many locations in the RCS, and the formation of steam bubbles holds up the pressure decrease.
- 6.
Containment pressure increases rapidly as the hot coolant is released into the containment volume. The maximum pressure reached is -35 psia.
- 7.
The large value of cold-leg break flow illustrates the rapid rate of inventory loss at the outset of the accident.
- 8.
The rapid increase in BIT flow reflects the initiation of high pressure injection; the CCPs are the first pieces of emergency equipment started by the DBA sequencer following an ESF actuation (one CCP is already running at the start of the transient).
TRANSIENT 5.76 (CONT'D)
USNRC Technical Training Center 5.76-1 Rev O1UZ USNRC Technical Training Center 5.76-1 I................
I /t.........
Transient 5.76 Guide Rev 0102
Point Explanation
- 9.
Safety injection system flow at first increases rapidly with the initiation of intermediate head injection (the safety injection pumps are started by the DBA sequencer a few seconds after the CCPs). This illustrates that the RCS depressurizes quickly to below the shutoff head of the pumps. SI system flow then gradually increases as the pump discharge pressure decreases (characteristic of centrifugal pumps).
- 10.
The drop in cold-leg accumulator level reflects the emptying of the accumulators when the RCS pressure falls below the accumulator nitrogen cover pressure (600 psig).
- 11.
RRIR flow remains at 0 over the time span of the transient as the reactor coolant pressure stays above the shutoff head of the RHR pumps. The RHR pumps were started by the DBA sequencer shortly after the start of the accident and are recirculating to their suctions.
- 12.
Containment pressure decreases as the containment fan coolers remove heat from and condense steam in the containment volume. The highest pressure reached in containment
(-20 psig) does not exceed the containment spray initiation setpoint.
What this transient illustrates:
- 1. The loss of inventory from the RCS and the reduction in RCS pressure associated with a LOCA, and the resulting protection system responses.
- 2. A low pressurizer pressure ESF actuation and the characteristic response of charging flow.
- 3. The development of saturated conditions in the RCS.
- 4. The responses of the ECCSs and the different pressures at which they inject.
- 5. The reduction in containment pressure due to containment fan cooler operation.
USNRC Technical Training Center 5.76-2 Rev 0102 Westinghouse Technology Advanced Course Transient 5.76 Guide Rev 0102 USNRC Technical Training Center 5.76-2
TRANSIENT 5.77 LOSS-OF-FEEDWATER ATWS Initial Conditions:
BOL Bank D Rod Position: 219 steps T.rg: 585.3 'F Charging flow provided by one centrifugal charging pump Pressurizer Pressure: 2230 psig All control systems in automatic Nuclear Power: 100%
Reactor trip breakers are failed in the closed position Initiating Event: Simultaneous trip of both main feed pumps Point Explanation
- 1.
Feed flow drops to 0 rapidly with the loss of both main feed pumps.
- 2.
Generator load decreases rapidly with the turbine setback (acts through the load limit circuit) initiated by the feed pump trips.
- 3.
Steam generator level rapidly decreases out of the narrow-range level indicating range as a result of (1) shrink and (2) the stoppage of feed flow and continued steaming.
- 4.
Feed flow comes back on scale with the initiation of AFW on low-low SG level.
- 5.
Generator load drops to 0 when the turbine is tripped by the ATWS mitigation system actuation circuit (AMSAC). In accordance with the design of the Trojan AMSAC, the trip occurs 25 sec after 3 of the SG levels reach the low-low level setpoint.
- 6.
T,,g increases with the power mismatch resulting from continued nuclear power generation and the loss of the turbine load. Even the development of full-blast steam dump flow within the first minute cannot halt the increasing trend.
- 7.
Bank D rod position decreases as the rod control system inserts the rods at the maximum rate (72 steps/min) in response to large inputs from the power mismatch circuit (setback and turbine trip) and from the temperature mismatch circuit (Tvg >> Tref).
- 8.
Nuclear power decreases rapidly due to the negative reactivity associated with the rod insertion and the coolant temperature increase.
- 9.
Steam dump demand rapidly increases to maximum with the large T,,,g - Tef difference. The steam flow graph indicates that the dumps are first armed by a loss-of-load arming signal and then remain armed by a turbine trip arming signal following the turbine trip.
- 10.
Steam flow and steam pressure decrease as the SG inventories are boiled off to near empty.
- 11.
The increase in T,,g accelerates as the SG heat sink is almost completely gone.
TRANSIENT 5.77 (CONT'D)
Westingyhouse Technoloev3 Advanced Course Transient 5.77 Guide USNRC Technical Training Center 5.77-1 Rev 0102
Westinohouse Technolofyv Advanced Course Taset57 ud Point Explanation
- 12.
Pressurizer pressure reflects PORV and safety valve lifts as the pressurizer is solid and coolant temperature is still increasing. At least some of the valve lifts probably result in water release.
- 13.
Feed flow increases when the SG pressure has dropped below the condensate pump discharge pressure.
- 14.
T., decreases rapidly with the abrupt increase in SG heat transfer associated with the introduction of condensate flow. At this point the core heat ouput has been reduced to decay heat levels by the rod insertion.
- 15.
Pressurizer level drops rapidly with the rapid contraction of the reactor coolant associated with the coolant temperature decrease.
- 16.
Pressurizer pressure rapidly drops to below the low pressure ESF actuation setpoint (1807 psig) with the expansion of the steam bubble accompanying the coolant contraction.
- 17.
The rapid increase in BIT flow (followed closely by the rapid increase in safety injection system flow) reflects the ESF actuation and the low RCS pressure.
- 18.
Pressurizer level increases as ECCS flow (with letdown isolated) fills the pressurizer.
- 19.
Pressurizer pressure increases to the PORV lift setpoint as the pressurizer goes solid again. Note that the solid plant conditons are attained - 5 min after the indicated pressurizer level reaches 100%. At the very low pressure experienced throughout much of this transient (- 900 psig), the indicated level greatly overstates the actual level. See the attached figures for a more detailed explanation of this phenomenon. In addition, the pressurizer is not completely filled when the level reaches the upper taps of the level detectors.
- 20.
Pressurizer pressure "squiggles" reflect PORV lifts after the pressurizer goes solid.
Instrument air to containment has been isolated on the ESF actuation, but the pressurizer PORVs are equipped with air accumulators.
What this transient illustrates:
- 1. The large reduction in heat removal capability with the loss of main feedwater, and the inability of AFW alone to hold Tayg at normal operating values at high reactor powers.
- 3. The development of solid plant conditions due to overheating and overfilling of the RCS.
- 4. A turbine setback caused by the loss of a main feed pump.
USNRC Technical Training Center 5.77-2 Rev U1UZ 5.77-2 Transient 5.77 Guide Rev 0102 USNRC Technical Training Center