Peter E. Katz 1650 Calvert Cliffs Parkway Vice President Lusby, Maryland 20657 Calvert Cliffs Nuclear Power Plant 410 495-4455 Constellation Generation Group, LLC 410 495-3500 Fax Energy Group Constellation September 17, 2002 U. S. Nuclear Regulatory Commission Washington, DC 20555 ATTENTION: Document Control Desk

SUBJECT:

Calvert Cliffs Nuclear Power Plant Unit No. 1; Docket No. 50-317 Inservice Inspection Report Please find enclosed the Inservice Inspection Report for the Calvert Cliffs Nuclear Power Plant Unit 1.

This inspection fulfilled the intentions and requirements stated in our program plan and our commitment to comply with American Society of Mechanical Engineers Code Section XI Inservice Inspection Requirements.

Should you have questions regarding this matter, we will be pleased to discuss them with you.

Very truly yours, PEK/TWG/bjd

Enclosures:

(1) ASME Boiler & Pressure Vessel Code Section XI, Form NIS-1 (2) ASME Boiler & Pressure Vessel Code Section XI, Form NIS-2 cc: Mr. Craig Lowry (Without Enclosures)

R. S. Fleishman, Esquire H. J. Miller, NRC J. E. Silberg, Esquire Resident Inspector, NRC Director, Project Directorate I-1, NRC R. I. McLean, DNR D. M. Skay, NRC IN

ENCLOSURE (1)

ASME BOILER & PRESSURE VESSEL CODE SECTION XI, FORM NIS-1 Calvert Cliffs Nuclear Power Plant September 17, 2002

Page 1 of 2 NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS (As required by the Provisions of the ASME Code Rules)

1. Owner Constellation Energy, P.O. Box 1475, Baltimore, MD 21203 (Name and Address of Owner)
2. Plant Calvert Cliffs Nuclear Power Plant, 1650 Calvert Cliffs Pk, Lusby, MD 20657 (Name and Address of Plant)
3. Plant Unit I 4 Owner Certificate of Authorization (if required) N/A
5. Commercial Service Date 5/08/1975 6 National Board Number for Unit 20911
7. Components Inspected Component or Manufacturer or Manufacturer or Installer State or National Board No Appurtenance Installer Serial No Province No Reactor Pressure Vessel Combustion Engineering CE-67107 14000NV 20911 Pressurizer Combustion Engineering CE-67602 14000NV 20915 Steam Generator #11 Combustion Engineering CE-67504 14000NV 20922 Steam Generator #12 Combustion Engineering CE-67505 14000NV 20923 Reactor Coolant Pipe Combustion Engineering N/A N/A N/A Safety Injection Bechtel N/A N/A NIA Pioin/Sunoorts Pressurizer Spray Bechtel N/A N/A N/A Pioine/Sunoorts Shutdown Cooling Bechtel N/A N/A N/A PioinO/SuDoorts Main Steam Bechtel N/A N/A N/A Pinin*/Sunnorts Charging Piping/Supports Bechtel N/A N/A N/A Letdown Piping/Supports Bechtel N/A N/A N/A Pressurizer Safety & Relief Bechtel N/A N/A NIA Pioing/Sunoorts Feedwater Piping/Supports Bechtel N/A N/A N/A
8. Examination Dates 4/28/2000 to 6/19/2002
9. Inspection Period Identification: 1999 to 2002
10. Inspection Interval Identification: 1999 to 2009
11. Applicable Edition of Section XI 1998 Addenda None
12. Date/Revision of Inspection Plan: CCNPP Units I & 2 Third Interval ISI Plan, Revision 0
13. Abstract of Examinations and Tests Include a list of examinations and tests and a statement concerning status of work required for the Inspection Plan.

NIS-1 Page 2 of 2 The examinations reported herein constitute the fifteenth report of Inservice Inspections performed at Calvert Cliffs Unit 1, and the second report within the first period of the third interval of commercial operation. The examinations for this inspection period, as required by the Third Interval Plan for Calvert Cliffs Units 1 & 2, were performed in accordance with the 1998 Edition of ASME Code Section XA with No Addenda. Nondestructive examination data and procedures are available at the site for review.

14. Abstract of Results of Examinations and Tests A visual inspection of component 6-SI-1214-R-1 revealed a loose bolt at the pipe clamp on snubber 1-52-60.
15. Abstract of Corrective Measures The deficiency found on 6-S1-1214-R-1 was corrected, and four additional inspections were performed; no other problems were identified.

Steam Generators # 11 and #12 lower assemblies were replaced with new units manufactured by B&W Canada.

We certify that a) the statements made in this report are correct, b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI, and c) corrective measures taken conform to the rules of the ASME Code,Section XI.

Certificate of Authorization No (if applicable) N/A Expiration Date Signed Constellation Energy By Keith M. Hoffman Date 9/3/2002 Owner CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectores and the State or provinces of MARYLAND and employed by FACTORY MUTUAL INSURANCE COMPANY of JOHNSTON, RI have inspected the components described in this Owner's Report during the peroid 4/28/2000 to 6/1912002 , and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in this Owner's Report in accordance with the inspection plan and as required by the ASME Code,Section XI By signing this certificate neither the Inspector nor his employer makes and any warranty, expressed or implied, concerning the examinations, tests, and corrective measures described in this Owner's Report Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection R. W. Lawrence / Commissions s(ja 67ZX_. Mb.-lb6 Inspector's Signature National Board, State, Province, and Endorsements Date . Zoo Z-.

ATTACHMENT 1 Page 1 of 19 Inservice Inspection Report 3-1-2

1. Owner: Constellation Ener-gy, P 0. Box 1475, Baltimore, MD 21203
2. Plant: Calv ert Cliffs Nuclear Power Plant, 1650 Calvert Cliffs Pk, Lusby, MD 20657 3 Plant Unit 1
4. Owner Certificate of Authorization( If Req.) N/A 5 Commercial Service Date: 5/08 /1975
6. National Board Number for Unit: 209111 EXAM CATEGORY I ITEM NUMBER: --I Reactor Coolant System I Reactor Vessel Head Summary/ID No Component ID Component Description Comments 140000 Head Penetrations 1-74 Reactor Vessel Head CRDM, ICI & Vent This examination was performed in response to NRC Line Penetrations Bulletin 2002-01. The exam was performed by Framatome ANP personnel with CCNPP Level IIand Level III oversight. Pictures are located at CCNPP for review Exam Results-2002VE002 Accept VARIOUS Summary/ID No Component ID Component Descnption Comments 170000 BACI CNTMT Mode 3 PS MODE 3 POST SHUTDOWN WALKDOWN Exams performed per NRC Generic Letter 88-05 & MN 3-301 (Boric Acid Program); all components with boric acid build-up listed in IR3-076-465, IR3-076-466, and IR3-076-467. No active leakage was noted Exam Results, 2002BV134 Accept 170200 BACI AUX BLDG Mode 5/6 MODE 5/6 AUXILLARY BUILDING Exams per NRC GL 88-05 & MN-3-301 (Boric Acid WALKDOWN Program) IR3-080-634 written due to active leakage on 1-cvc-210q in the 5' VCT Rm IR3-080-635 wntten for various components with boric acid build-up No active leakage seen under this MO.

Exam Results 2002BV145 Accept 170100 BACI CNTMT Mode 5/6 MODE 5/6 CONTAINMENT WALKDOWN Exams per NRC GL 88-05 & MN-3-301(Boric Acid Program). Lower RPV head examined remotely.

Videotape with report. Htr pen. examined with insulation removed lAW requ for a VT-1 exam. New S/G manway studs with new S/G. No Boric Acid seen in these areas.

Exam Results-2002BV139 Accept

ATTACHMENT I Page 2 of 19 Inservice Inspection Report 3-1-2

1. Owner: Constellati on Energy, P 0 Box 1475, Baltimore, MD 21203
2. Plant. Calvert Cliffs Nuclear Power Plant, 1650 Calvert Cliffs Pk, Lusby, MD 20657
3. Plant Unit: 1 4 Owner Certificate of Authorization( If Req) N/_A
5. Commercial Service Date: 510811975
6. National Board Number for Unit: 20911 EXAM CATEGORY I ITEM NUMBER: AUGMT I ..---

MAIN STEAM Summary/ID No Component ID Component Description Comments 422000 36-MS-1201-3LU LONGITUDINAL SEAM Allocated in accordance with CCNPP Augmented Inservice Examination Program.

Exam Results' 2002BU034 Accept 2002BM052 Accept 427600 34-MS-1202-13LU LONGITUDINAL SEAM Allocated in accordance with CCNPP Augmented Inservice Examination Program.

Exam Results 2002BU036 Accept 2002BM062 Accept 427700 34-MS-1202-13LD LONGITUDINAL SEAM Allocated in accordance with CCNPP Augmented Inservice Examination Program Exam Results:

2002BM036 Accept 2002BU037 Accept 427650 34-MS-1202-13 PIPE TO PIPE Allocated in accordance with CCNPP Augmented Inservice Examination Program Exam Results, 2002BM034 Accept 2002BU035 Accept 431750 6-MS-1208-1 ON PIPE TO PIPE Allocated in accordance with CCNPP Augmented Inservice Examination Program Exam Results*

2002BU027 Accept 2002BM038 Accept 431900 6-MS-1208-11N PIPE TO VALVE 1-CV-4071 Allocated in accordance with CCNPP Augmented Inservice Examination Program. Single side access due to configuration. Weld preparation prevented complete coverage of far side. This item may be considered for relief.

Exam Results*

2002BU028 Accept 2002BM039 Accept

ATTACHMENT 1 Page 3 of 19 Inservice Inspection Report 3-1-2

1. Owner. Constellation EEnerp.qy P 0 Box 1475, Baltimore, MD 21203
2. Plant. Juclear Power Plant, 1650 Calvert Cliffs Pk. Lusby, MD 20657 Calvert Cliffs IN 3 Plant Unit 1 4 Owner Certificate of Authorization( If Req) N/A
5. Commercial Service Date. 5108/1975
6. National Board Number for Unit. 20911 EXAM CATEGORY I ITEM NUMBER: B-A l B1.40 REACTOR PRESSURE VESSEL Summary/ID No. Component ID Component Description Comments
  • Weld metal examined 100%; base metal exam limited 002350 6-209A HEAD TO FLANGE WELD due to support lugs. "Flange configuration, welded lugs, insulation support nng, and weld transition area prevented full exam coverage This item may be considered for relief.

Exam Results' 2002BU025 Accept 2002BM071 Accept EXAM CATEGORY / ITEM NUMBER: B-G-1 I B6.10 REACTOR PRESSURE VESSEL Summary/ID No Component ID Component Description Comments 003550 1-54 RPV NUTS 1- 54 VT of Rx Head Nuts 1 thru 18, minor mechanical damage, surface nicks, hammer marks. Nuts #1, 4, 15, and 16 showing a higher degree of mechanical damage.

Areas of mechanical damage of the 18 nuts showed no degradation.

Exam Results 2002BV022 Accept EXAM CATEGORY I ITEM NUMBER: B-G-1 I B6.30 REACTOR PRESSURE VESSEL Summary/ID No Component ID Component Description Comments STUD NUMBERS 1 THROU RPV STUDS Examined RPV Stud numbers 1 through 18 003500 Exam Results 2002BM068 Accept 2002BM056 Accept 2002BU038 Accept 2002BU039 Accept 2002BM067 Accept EXAM CATEGORY I ITEM NUMBER: B-G-1 I B6.50 REACTOR PRESSURE VESSEL Summary/ID No Component ID Component Description Comments 003600 WASHER NUMBERS I THR RPV WASHERS 1-54 Washers 1 thru 18 examined, the inner diameter face area of all 18 washers showed minor (small) pitting with no degradiation Exam Results' 2002BV023 Accept

ATTACHMENT 1 Page 4 of 19 Inservice Inspection Report 3-1-2

1. Owner: Constellati on Ener-gy, P.O. Box 1475, Baltimore, MD 21203
2. Plant: Calvert Cli ffs Nuclear Power Plant, 1650 Calvert Cliffs Pk, Lusby, MD 20657
3. Plant Unit 1 4 Owner Certificate of Authonzation( If Req) N/A
5. Commercial Service Date: 5108/1975
6. National Board Number for Unit 20911 EXAM CATEGORY I ITEM NUMBER: B-J I B9.11 PRESSURIZER SPRAY Summary/ID No Component ID Component Description Comments 118150 4-PS-i 003M-6 ELBOW TO PIPE Exam Results' 2002BP067 Accept 2002BU032 Accept 118100 4-PS-1003M-5 PIPE TO ELBOW Exam Results:

2002BU031 Accept 2002BP061 Accept SAFETY INJECTION Summary/ID No Component ID Component Descnrption Comments 117200 6-SI-1002-29 ELBOW TO PIPE Exam Results.

2002BU066 Accept 2002BP257 Accept 117300 6-SI-1002-31 ELBOW TO PIPE Exam Results' 2002BP157 Accept 2002BU068 Accept 117550 6-S I-1003-23 ELBOW TO PIPE Exam Results' 2002BU070 Accept 2002BP256 Accept 114350 12-SI-1009-16 NOZZLE TO SAFE END Exam Results' 2002BU077 'Accept 2002BP296 Accept 117350 6-SI-1002-32 PIPE TO BRANCH CONNECTION

  • The PDI austenitic UT procedure not qualified to detect flaws on far side of single side access welds; 50% coverage is max credit allowed Far side of weld examined to max extent possible by approved PDI techniques Item may be considered for relief.

Exam Results' 2002BU069 Accept 2002BP259 Accept 117150 6-SI-1002-28 PIPE TO ELBOW Exam Results' 2002BP158 Accept 2002BU065 Accept 117250 6-S1-1002-30 PIPE TO ELBOW Exam Results' 2002BU067 Accept

ATTACHMENT 1 Page 5 of 19 Inservice Inspection Report 3-1-2

1. Owner: Con*stellation Energy. P.O Box 1475, Baltimore, MD 21203
2. Plant: Calv ert Cliffs Nuclear Power Plant, 1650 Calvert Cliffs Pk. Lusby, MD 20657
3. Plant Unit 1
4. Owner Certificate of Authonzation( If Req) NIA
5. Commercial Service Date: 5/0811975
6. National Board Number for Unit 20911 2002BP258 Accept SHUTDOWN COOLING Summary/ID No Component ID Component Description Comments 111350 14-SC-1004-5 ELBOW TO PIPE Exam Results' 2002BU062 Accept 2002BP154 Accept 113000 14-SC-1 004-29 ELBOW TO PIPE Exam Results:

2002BU029 Accept 2002BP060 Accept 111750 14-SC-1004-10 PIPE TO ELBOW Exam Results' 2002BU063 Accept 2002BP156 Accept 112500 14-SC-1004-20 PIPE TO ELBOW Exam Results' 2002BP155 Accept 2002BU064 Accept

ATTACHMENT 1 Page 6 of 19 Inservice Inspection Report 3-1-2

1. Owner: Constellation Energy, P 0 Box 1475, Baltimore, MD 21203
2. Plant: Calvert Cliffs Nuclear Power Plant, 1650 Calvert Cliffs Pk. Lusby, MD 20657
3. Plant Unit: 1
4. Owner Certificate of Authorization( If Req) N/A 5 Commercial Service Date: 5/0811975 6 National Board Number for Unit: 20911 EXAM CATEGORYI ITEM NUMBER: B-J I B9.21 CHARGING (CVCS)

Summary/ID No Component ID Component Description Comments 128250 2-CV-1004-6B ELBOW TO PIPE Exam Results:

2002BP247 Accept 128350 2-CV-1004-6D ELBOW TO PIPE Exam Results*

2002BP249 Accept 131050 2-CV-1006-14N ELBOW TO PIPE Exam Results, 2002BP244 Accept 130450 2-CV-1005-29 NOZZLE TO SAFE END Exam Results 2002BP304 Accept 128300 2-CV-1004-6C PIPE TO ELBOW Exam Results*

2002BP248 Accept 131000 2-CV-1006-13N PIPE TO ELBOW Exam Results*

2002BP243 Accept 131150 2-CV-1006-15N PIPE TO TEE Exam Results 2002BP240 Accept 128100 2-CV-1004-5N TEE TO PIPE Exam Results*

2002BP246 Accept 129100 2-CV-1 005-9N TEE TO PIPE Exam Results, 2002BP241 Accept 129250 2-CV-1005-10B TEE TO PIPE Exam Results*

2002BP242 Accept PRESSURIZER SPRAY Summary/ID No. Component ID Component Description Comments 118550 3-PS-1001-1 NOZZLE TO SAFE END Exam Results' 2002BP303 Accept 120350 3-PS-1002-1 NOZZLE TO SAFE END Exam Results" 2002BP300 Accept REACTOR COOLANT DRAINS Summary/ID No Component ID Component Description Comments

ATTACHMENT 1 Page 7of 19 Inservice Inspection Report 3-1-2

1. Owner. Constellation Energy, P 0 Box 1475, Baltimore, MD 21203
2. Plant: Calvert Cliffs Nuclear Power Plant. 1650 Calvert Cliffs Pk. Lusbv. MD 20657
3. Plant Unit 1
4. Owner Certificate of Authonzation( If Req) NIA
5. Commercial Service Date, 5/08/1975
6. National Board Number for Unit. 20911 131500 2-DR-1004-1 NOZZLE TO SAFE END Exam Results*

2002BP301 Accept EXAM CATEGORY I ITEM NUMBER: B-J I B9.32 REACTOR COOLANT Summary/ID No Component ID Component Description Comments 101900 30-RC-1 1A-5/2-DR-1 003 2-IN BRANCH CONNEC TION Exam Results 2002BM445 Accept 102600 30-RC-11A-10/2-CV-1005 2-IN. BRANCH CONNEC TION Exam Results, 2002BM448 Accept 104150 30-RC- IB-5/2-DR-1004 2-IN BRANCH CONNEC TION Exam Results 2002BM446 Accept 104850 30-RC-1IB-10/3-PS-1002 2-IN. BRANCH CONNEC TION Exam Results 2002BM450 Accept 107050 30-RC-12A-5/2-LD-1004 2-IN. BRANCH CONNEC TION Exam Results 2002BM447 Accept 102700 30-RC-11A-1013-PS-1001 3-IN. BRANCH CONNEC TION Exam Results 2002BM449 Accept

ATTACHMENT I Page 8 of 19 Inservice Inspection Report 3-1-2

1. Owner: Constellation Ener.qy, P 0 Box 1475, Baltimore, MD 21203
2. Plant Calvert Cliffs r, Nuclear Power Plant, 1650 Calvert Cliffs Pk, Lusby, MD 20657 3 Plant Unit: 1
4. Owner Certificate of Authonzation( If Req) NI._A
5. Commercial Service Date: 5/08/1975
6. National Board Number for Unit: 20911 EXAM CATEGORY I ITEM NUMBER: B-J / B9.40 CHARGING (CVCS)

Summary/ID No Component ID Component Descr1ption Comments 127300 2-CV-1003-33 COUPLING-TO-P IPE Exam Results, 2002BP293 Accept 126100 2-CV-1003-8D PIPE TO VALVE 1-CVC-185 Exam Results' 2002BP254 Accept 126000 2-CV-1003-8B PIPE TO VALVE 1-CVC-389 Exam Results 2002BP252 Accept 125950 2-CV-1003-8A TEE TO PIPE Exam Results:

2002BP251 Accept 125800 2-CV-1003-5 VALVE 1-CV-517 TO PIPE Exam Results 2002BP294 Accept 126050 2-CV-1003-8C VALVE 1-CVC-38 9 TO PIPE Exam Results 2002BP253 Accept LETDOWN LINES (CVCS)

Summary/ID No Component ID Component Desci iption Comments 125550 2-LD-1004-8C PIPE TO TEE Exam Results 2002BP308 Accept 125450 2-LD-1004-8A PIPE TO VALVE 1-CVC-397 Exam Results:

2002BP306 Accept 125500 2-LD-1004-8B VALVE 1-CVC-39 7 TO PIPE Exam Results*

2002BP307 Accept REACTOR COOLANT DRAINS Summary/ID No. Component ID Component DescinptEon Comments 131550 2-DR-1004-1A SAFE END TO PIIPE Exam Results 2002BP302 Accept

ATTACHMENT 1 Page 9 of 19 Inservice Inspection Report 3-1-2

1. Owner: Constellation Energy, P 0. Box 1475, Baltimore, MD 21203
2. Plant Calvert Cliffs Nuclear Power Plant. 1650 Calvert Cliffs Pk. Lusbv. MD 20657 3 Plant Unit. 1 4 Owner Certificate of Authorization( If Req.) NIA
5. Commercial Service Date. 5/08/1975
6. National Board Number for Unit: 20911 EXAM CATEGORY I ITEM NUMBER: B-M-2 I B12.50 SAFETY INJECTION Summary/ID No Component ID Component Descnption Comments 135650 1-SI-217 VALVE BODIES GROUP 5 Exam Results:

2002BV112 Accept EXAM CATEGORY I ITEM NUMBER: B-P I B15.10 REACTOR COOLANT Summary/ID No Component ID Component Description Comments 138650 PRESSURE RETAINING C REACTOR PRESSURE VESSEL Exam Results" 2002BV178 Accept EXAM CATEGORY IITEM NUMBER: B-P I B15.20 PRESSURIZER Summary/ID No Component ID Component Description Comments 138750 PRESSURE RETAINING C PRESSURIZER Exam Results 2002BV179 Accept EXAM CATEGORY I ITEM NUMBER: B-P / B15.30 STEAM GENERATOR Summary/ID No Component ID Component Description Comments 138850 PRESSURE RETAINING C STEAM GENERATORS Exam Results, 2002BV180 Accept EXAM CATEGORY I ITEM NUMBER: B-P I B15.50 RCS SI CVCS Summary/ID No Component ID Component Description Comments 139050 PRESSURE RETAINING C PIPING Exam Results:

2002BV182 Accept EXAM CATEGORY I ITEM NUMBER: B-P I B15.60 REACTOR COOLANT Summary/ID No Component ID Component Description Comments 139150 PRESSURE RETAINING C PUMPS Exam Results 2002BV183 Accept

ATTACHMENT 1 Page 10 of 19 Inservice Inspection Report 3-1-2

1. Owner. Constellation Energy, P 0 Box 1475, Baltimore, MD 21203
2. Plant: Calvert Cliffs Nuclear Power Plant. 1650 Calvert Cliffs Pk. Lusbv. MD 20657
3. Plant Unit 1
4. Owner Certificate of Authorization( If Req.) NIA
5. Commercial Service Date: 5/08/1975
6. National Board Number for Unit: 20911 EXAM CATEGORY I ITEM NUMBER: B-P I B15.70 SI CVCS Summary/ID No Component ID Component Descnption Comments 139250 PRESSURE RETAINING C VALVES Exam Results' 2002BV184 Accept EXAM CATEGORY I ITEM NUMBER: C-C I C3.20 SAFETY INJECTION Summary/ID No Component ID Component Description Comments 302750 18-SI-1203-H-2, R-1 INTEGRAL ATTACHMENT Exam Results' 2002BP071 Accept 304950 18-S1-1204-H-10, R-6 INTEGRAL ATTACHMENT Exam Results*

2002BP073 Accept 309300 14-SI-1211-H-9 INTEGRAL ATTACHMENT

  • Pipe attachment in way of examination area.

Exam Results, 2002BP035 Accept 310800 12-SI-1214-H-8 INTEGRAL ATTACHMENT Exam Results, 2002BP019 Accept 315500 10-SI-1206-R-4 INTEGRAL ATTACHMENT TWO STANCHIONS ATTACHED TO 10" HC-3-1006 180 DEGREES FROM EACH OTHER Exam Results' 2002BP059 Accept 316050 10-S1-1207-R-18 INTEGRAL ATTACHMENT Exam Results:

2002BP292 Accept 319150 8-SI-1221-H-4 INTEGRAL ATTACHMENT Exam Results' 2002BP025 Accept 331150 6-SI-1213-A-1 INTEGRAL ATTACHMENT Exam Results:

2002BP234 Accept 332650 6-S1-1214-R-1 INTEGRAL ATTACHMENT Exam Results' 2002BP318 Accept

ATTACHMENT I Page 11 of 19 Inservice Inspection Report 3-1-2

1. Owner: Constellation En er.y, P 0 Box 1475, Baltimore, MD 21203
2. Plant: Calvert Cliffs Nucclear Power Plant, 1650 Calvert Cliffs Pk. Lusby, MD 20657
3. Plant Unit: 1
4. Owner Certificate of Authoonzation( If Req.) N/._A 5 Commercial Service Date* 5/08/1975
6. National Board Number for Unit 20911 EXAM CATEGORY I ITEM NUMBER: C-F-1 I C5.11 SAFETY INJECTION Summary/ID No Component ID Component Descript ion Comments
  • The PD1 procedure Is not qualified to detect defects on 310650 12-S1-1214-12 ELBOW TO VALVE 1-SI-306 the far side of single side access Austenitic welds The inaccessable side has been examined with approved PDI techniques. **This item may be considered for relief.

Exam Results 20021BU002 Accept 2002BP018 Accept

ATTACHMENT 1 Page 12 of 19 Inservice Inspection Report 3-1-2

1. Owner. Constellation Energy, P.O. Box 1475, Baltimore, MD 21203
2. Plant. Calvert Clr ffs Nuclear Power Plant, 1650 Calvert Cliffs Pk, Lusby, MD 20657
3. Plant Unit. 1
4. Owner Certificate of Authorization( If Req.) N/A
5. Commercial Service Date: 5/0811975
6. National Board Number for Unit: 20911 EXAM CATEGORY I ITEM NUMBER: C-F-1 I Exempt SAFETY INJECTION Summary/ID No Component ID Component Description Comments 307500 14-SI-1201-3 ELBOW TO FLANGE
  • Exam elbow side only due to configuration The PDI procedure not qualified to detect defects on far side of single side access welds. The far side has been examined to max extent achievable by approved PDI techniques May be considered for relief.

Exam Results, 20021BU011 Accept 2002BP030 Accept 304750 18-SI-1204-2 ELBOW TO PIPE Exam Results, 2002BU060 Accept 2002BP076 Accept 316000 10-S I-1207-3 ELBOW TO PIPE Exam Results 20021BU019 Accept 2002BP036 Accept 317350 8-SI-1220-6 ELBOW TO PIPE Exam Results 20021BU005 Accept 2002BP021 Accept 319100 8-S1-1221-3 ELBOW TO PIPE Exam Results 20021 BU008 Accept 2002BP024 Accept 321200 6-SI-1203-11 ELBOW TO REDUCER Exam Results, 2002BU024 Accept 2002BP053 Accept 328700 6-SI-1211-14 ELBOW TO REDUCER Exam Results*

2002BP034 Accept 20021BU018 Accept 310850 12-SI-1214-15 ELBOW TO TEE Exam Results 2002BP020 Accept 20021BU004 Accept 321150 6-SI-1003-10 FLANGE TO ELBOW

  • PDI procedure not qualified to detect defects on the far side of single side access welds; far side examined to maximum extent achievable by approved PDI techniques. This item may be considered for relief.

Exam Results 2002BP052 Accept 2002BU023 Accept

ATTACHMENT I Page 13 of 19 Inservice Inspection Report 3-1-2

1. Owner: Constellation Energy. P.O. Box 1475, Baltimore, MD 21203
2. Plant: Calvert Cliffs Nuclear Power Plant, 1650 Calvert Cliffs Pk, Lusby, MD 20657
3. Plant Unit' 1
4. Owner Certificate of Authorization( If Req) N!A
5. Commercial Service Date* 5/08/1975
6. National Board Number for Unit 20911 324050 6-SI-1206-11 FLANGE TO ELBOW
  • PDI procedure not qualified to detect defects on the far side of single side access welds; far side examined to maximum extent achievable by approved PDI techniques This item may be considered for relief.

Exam Results' 2002BP032 Accept 20021BU016 Accept 313450 10-SI-1203-5 FLANGE TO PIPE

  • Examined Pipe side only due to configuration. The exam volume on opposite side examined by PDI techniques, but credit cannot be taken for this exam since PDI procedure is not qualified for this volume.

This item may be considered for relief Exam Results' 2002BU026 Accept 2002BP047 Accept 302200 18-S1-1203-1 PIPE TO ELBOW Exam Results:

2002BU059 Accept 2002BP075 Accept 302800 18-S I-1203-7 PIPE TO ELBOW Exam Results' 2002BP135 Accept 20021BU013 Accept 309750 12-SI-1213-6 PIPE TO ELBOW Exam Results' 20021BU010 Accept 2002BP029 Accept 318150 8-SI-1220-16 PIPE TO ELBOW Exam Results' 2002BP022 Accept 20021BU006 Accept 318250 8-SI-1220-18 PIPE TO ELBOW Exam Results' 2002BP023 Accept 20021BU007 Accept 328000 6-SI-1211-2 PIPE TO ELBOW Exam Results' 2002BP044 Accept 2002BU021 Accept 312850 10-SI-1202-3 PIPE TO FLANGE *Since PDI Aust Pipe Procd not qual'd to detect defects on far side of single sided welds, max coverage claimed can be 50%. Additional constraint of branch connection lowers coverage to 47%. Far side examined to max extent possible with PDI techniques.

Exam Results' 20021BU015 Accept 2002BP026 Accept

ATTACHMENT I Page 14 of 19 Inservice Inspection Report 3-1-2

1. Owner. Constellaticon Energy. P.O Box 1475, Baltimore, MD 21203
2. Plant: Calvert Clifffs Nuclear Power Plant, 1650 Calvert Cliffs Pk. Lusby, MD 20657
3. Plant Unit 1
4. Owner Certificate of Authorization( If Req) N/A
5. Commercial Service Date: 5108/1975 6 National Board Number for Unit. 20911 315650 10-SI-1206-10 PIPE TO FLANGE Exam Results:

2002BP048 Accept 328500 6-S1-1211-10 PIPE TO FLANGE

  • PDI procedure not qualified to detect defects on the far side of single side access welds, far side examined to maximum extent achievable by approved PDI techniques. This item may be considered for relief.

Exam Results' 2002BP033 Accept 20021BU017 Accept 312700 12-SI-1216-7 PIPE TO REDUCER Exam Results' 20021BU003 Accept 2002BP017 Accept 315750 10-SI-1206-12 PIPE TO REDUCER Exam Results' 2002BU022 Accept 2002BP045 Accept 305000 18-SI-1204-6 PIPE TO VALVE 1-SI-4146 Exam Results' 2002BP074 Accept 2002BU061 Accept 302550 18-SI-1203-3 PIPE TO VALVE MOV-4143 The PDI procedure not qualified to detect defects on far side of single side access welds. The far side has been examined to max extent achievable by approved PDI techniques May be considered for relief.

Exam Results 2002BP072 Accept 2002BU051 Accept 312800 10-S1-1202-2 REDUCER TO PIPE Exam Results 2002BP027 Accept 20021BU014 Accept 323300 6-SI-1206-1 TEE TO PIPE

  • PDI procedure not qualified to detect defects on the far side of single side access welds; far side examined to maximum extent achievable by approved PDI techniques This Item may be considered for relief.

Exam Results*

2002BP043 Accept 2002BU020 Accept 320650 6-SI-1203-1 VALVE 1-SI-401 TO PIPE

  • The PDI austenibc UT procedure not qualified to detect flaws on far side of single side access welds; 50% coverage is max credit allowed Far side of weld examined to max extent possible by approved PDI techniques Item may be considered for relief.

Exam Results' 2002BP058 Accept 2002BU071 Accept

ATTACHMENT 1 Page 15 of 19 Inservice Inspection Report 3-1-2

1. Owner: Constellation Energy. P 0 Box 1475, Baltimore, MD 21203
2. Plant: Calvert Cliffs Nuclear Power Plant, 1650 Calvert Cliffs Pk, Lusby, MD 20657 3 Plant Unit: 1
4. Owner Certificate of Authorization( IfReq.) N/A
5. Commercial Service Date: 5/08/1975
6. National Board Number for Unit. 20911 2002BU030 Accept 323850 6-SI-1206-7 VALVE 1-SI-411 TO PIPE
  • PDI procedure not qualified to detect defects on the far side of single side access welds: far side examined to maximum extent achievable by approved PDI techniques This item may be considered for relief.

Exam Results:

2002BP031 Accept 20021BU012 Accept 307400 14-S1-1201-1 VALVE SI-441 TO TEE

  • The PDI austenitic UT procedure not qualified to detect flaws on far side of single side access welds; 50% coverage is max credit allowed. Far side of weld examined to max extent possible by approved PDI techniques. Item may be considered for relief Exam Results' 20021BU009 Accept 2002BP028 Accept 2002BU073 Accept EXAM CATEGORY / ITEM NUMBER: C-F-2 / C5.51 MAIN STEAM Summary/ID No Component ID Component Description Comments 422050 36-MS-1201-3 PIPE TO VALVE 1-CV-4043 Exam Results' 2002BM032 Accept 2002BU033 Accept EXAM CATEGORY I ITEM NUMBER: C-F-2 / C5.81 MAIN STEAM Summary/ID No Component ID Component Description Comments 422300 36-MS-1202-1/6-RV-4000 6-IN. BRANCH CONNECTION Exam Results' 2002BP264 Accept 421350 36-MS-1 201-1/6-RV-3992 BRANCH CONNECTION Exam Results' 2002BM033 Accept EXAM CATEGORY I ITEM NUMBER: E-A I E1.11 Containmen t Structures Summary/ID No Component ID Component Description Comments A10000 Liner All accessible areas Overall Gen Visual Exam of Liner shows no evidence of damage or degradation. Areas identified are from mechanical means which have chipped/peeled coating not exposing the substrate.

Exam Results' 2002VE001

ATTACHMENT 1 Page 16 of 19 Inservice Inspection Report 3-1-2

1. Owner: Constellati on Energy, P.O Box 1475, Baltimore, MD 21203
2. Plant: Calvert Chf fs Nuclear Power Plant, 1650 Calvert Cliffs Pk, Lusby, MD 20657
3. Plant Unit: 1
4. Owner Certificate of Authonzation( If Req.) N/A
5. Commercial Service Date: 5/08/1975
6. National Board Number for Unit. 20911 EXAM CATEGORY / ITEM NUMBER: F-A / Fl. 10 SAFETY INJECTION Summarn/ID No Component ID Component Description Comments 602500 12-SI-1011-R-8 COMPONENT SUPPORT-SNUBBER THIS EXAM WAS DONE AS AN ADDITIONAL EXAM DUE THE FAILURE OF LTP# 710200 (REF. REPORT NO 2002BV118)

Exam Results' 2002BV128 Accept 601600 12-SI-1009-R-4 COMPONENT SUPPORT-SNUBBER- C THIS EXAM WAS DONE AS AN ADDITIONAL EXAM THERMAL DUE TO THE FAILURE OF LTP# 710200 (REF.

REPORT NO.2002BV1 18)

Exam Results*

2002BV129 Accept

ATTACHMENT 1 Page 17of 19 Inservice Inspection Report 3-1-2

1. Owner. Constellation Energ.q, P 0 Box 1475. Baltimore, MD 21203
2. Plant: Calvert Cliffs Nuclear Power Plant, 1650 Calvert Cliffs Pk, Lusby, MD 20657
3. Plant Unit: 1 4 Owner Certificate of Authorizabon( If Req) N/._A
5. Commercial Service Date: 5/0811975
6. National Board Number for Unit. 20911 EXAM CATEGORY I ITEM NUMBER: F-A I F1.20 SAFETY INJECTION Summary/ID No Component ID Component Description Comments 710150 6-SI-1214-H-1 COMPONENT SUPPORT THIS EXAM WAS DONE AS AN ADDITIONAL EXAM DUE TO THE FAILURE OF LTP# 710200.

(REF. REPORT NO. 2002BV118)

Exam Results*

2002BV126 Accept 710250 6-SI-1214-R-2 COMPONENT SUPPORT-SNUBBER THIS EXAM WAS DONE AS AN ADDITIONAL EXAM DUE TO THE FAILURE OF LTP# 710200 (REF.

REPORT NO.2002BV1 18)

Exam Results 2002BV127 Accept 709550 6-SI-1212 -R-9 COMPONENT SUPPORT-SNUBBER; C THERMAL Exam Results*

2002BV117 Accept 710200 6-SI-1214-R-1 COMPONENT SUPPORT-SNUBBER;C Snubber 1-52-60 has loose bolt at the pipe clamp. IR3 THERMAL 071-565 was written to address the problem; the loose bolt was corrected on the spot by snubber mechanic Additional exams were performed on LTP #s 601600, 602500, 710150, 710250.

Exam Results, 2002BV1 18 Reject 705550 10-SI-1206-H-6 COMPONENT SUPPORT-SPRING; C BOTH SPRING CANS (COMPONENT SUPPORT)

THERMAL SHOW 825# IN THE AS FOUND CONDITION THE +I 5% OF THE 825# IS WITHIN THE REFERENCE VALUE OF 800#.

Exam Results:

2002BV020 Accept 703750 14-SI-1211-H-9 COMPONENT SUPPORT-SPRING;C Northeast side of component support shows THERMAL misalignment; was measured with angle finder & found to be 40 off center. LEVEL II NOTE- Per engineenng the misalignment is acceptable.

Exam Results-2002BV013 Accept 713350 3-SI-1201-H-12 COMPONENT SUPPORT-SPRING,C THERMAL Exam Results 2002BV133 Accept 701800 18-SI-1203-H-2, R-1 COMPONENT SUPPORT; A-ONE DIR Exam Results 2002BV100 Accept 703325 14-SI-1204-R-1 COMPONENT SUPPORT; A-ONE DIR Spacers on bottom section of restraint found to be installed on outside of clevis. IR3-076-471 written to address problem. Problem corrected under MO #

1200200946. Reinspected restraint after corrective action - Satisfactory Exam Results

ATTACHMENT I Page 18 of 19 Inservice Inspection Report 3-1-2

1. Owner. Constellation Energy. P.O Box 1475, Baltimore, MD 21203 2 Plant: Calvert Cliffs Nuclear Power Plant, 1650 Calvert Cliffs Pk. Lusby, MD 20657
3. Plant Unit. 1
4. Owner Certificate of Authionzation( If Req) N/A 5 Commercial Service Date: 5/08/1975
6. National Board Number for Unit 20911 2002BV017 Reject 704100 12-SI-1214-H-8 COMPONENT SUPPORT; A-ONE DIR Spring can setting is not within 5% of reference setting IR3-070-374 written. Spring can setting adjusted under MO#11200201709 and verified setting at 4250# on 5/21/2002.

Exam Results:

2002BV135 Accept 705700 10-SI-1207-R-18 COMPONENT SUPPORT; A-ONE DIR OBSERVED CONCRETE SPALLING ON CEILING NEAR ATTACHMENT PLATE EAST SIDE, APPEARED TO BE PREVIOUS EXISTING CONDITION AS IT WAS PAINTED.

Exam Results' 2002BV005 Accept 706400 8-SI-1220-H-13 COMPONENT SUPPORT, A-ONE DIR Exam Results 2002BV146 Accept 703800 14-Sl-1211-R-7 COMPONENT SUPPORT; B-MULTI DIR Exam Results*

2002BV012 Accept 705600 10-SI-1206-R-4 COMPONENT SUPPORT; B-MULTI DIR Exam Results*

2002BV021 Accept 706700 8-SI-1221-H-4 COMPONENT SUPPORT; B-MULTI DIR Exam Results*

2002BV147 Accept 708450 6-SI-1210-A-1 COMPONENT SUPPORT; B-MULTI DIR Exam Results 2002BV116 Accept 716100 2-SI-1212-S-1 COMPONENT SUPPORT, B-MULTI DIR Exam Results, 2002BV007 Accept 716150 2-SI-1212-S-2 COMPONENT SUPPORT; B-MULTI DIR Exam Results*

2002BV008 Accept 716200 2-SI-1212-S-3 COMPONENT SUPPORT; B-MULTI DIR Exam Results, 2002BV010 Accept 716250 2-SI-1212-S-4 COMPONENT SUPPORT; B-MULTI DIR Exam Results*

2002BV009 Accept 716350 2-SI-1215-S-1 COMPONENT SUPPORT; B-MULTI DIR Exam Results*

2002BV003 Accept 716500 2-SI-1215-S-4 COMPONENT SUPPORT; B-MULTI DIR Exam Results, 2002BV006 Accept

ATTACHMENT 1 Page 19 of 19 Inservice Inspection Report 3-1-2

1. Owner: Constellation Enermy, P.O Box 1475, Baltimore, MD 21203
2. Plant: Calvert Cliffs Nuclear Power Plant, 1650 Calvert Cliffs Pk, Lusby, MD 20657
3. Plant Unit: 1
4. Owner Certificate of Authonzation( If Req) N/A
5. Commercial Service Date. 5/0811975
6. National Board Number for Unit. 20911 702600 18-SI-1204-R-6, H-10 COMPONENT SUPPORT;A-ONE DIR Exam Results*

2002BV099 Accept 708700 6-SI-1211-H-17 COMPONENT SUPPORT;A-ONE DIR Exam Results 2002BV011 Accept 709700 6-SI-1213-A-1 COMPONENT SUPPORT;A-ONE DIR Exam Results 2002BV113 Accept 708800 6-SI-1211-R-13 COMPONENT SUPPORT;B-MULTI DIR Exam Results 2002BV014 Accept 710450 6-SI-1217-R-9 COMPONENT SUPPORT;B-MULTI DIR Exam Results*

2002BV131 Accept 713400 3-SI-1201-R-10 COMPONENT SUPPORT;B-MULTI DIR Exam Results 2002BV132 Accept 716400 2-SI-1215-S-2 COMPONENT SUPPORT,B-MULTI DIR Exam Results 2002BV004 Accept

ENCLOSURE (2)

ASME BOILER & PRESSURE VESSEL CODE SECTION XI, FORM NIS-2 Calvert Cliffs Nuclear Power Plant September 17,2002

2002-1 Class 1 and 2 NIS-2's Completed I MWO No. R&R Number - " UEI',,- * -' ;Class,". Review Date 1199701954 98-1-186 lCKVSI-217 One 7/12/2002 1200001584 2000-1-077a 1CKVCVC-185 One 8/12/2002 1200001460 2000-1-104 1CV100E One 8/8/2002 1200005063 2001-1-010 1CV618 One 7/19/2002 1200005064 2001-1-011 1CV628 One 7/19/2002 1200004019 2001-1-012 1iCV638 One 7/19/2002 1200005065 2001-1-013 1CV648 One 7/19/2002 1200101169 2001-1-017 1RV469 One 7/17/2002 0199902341 2001-1-027 1#EB6-1008,R5 & H30 Two 7/15/2002 1200002465 2001-1-028 1HVMS-101 Two 7/1912002 1199900767 2001-1-031a 1HVSI-425 Two 8/8/2002 1199900767 2001-1-031b 1#DC2-1003 Two 8/8/2002 1200103259 2001-1-042 1PUMPRC11A(s) One 7/31/2002 1200002904 2001-1-047 1#GC5-1008 Two 7/17/2002 1200003521 2001-1-049 1 PUMPRC1 1B(s) One 8/15/2002 1200003048 2001-1-054 1 HVRC-1 180 One 7/19/2002 1200104120 2001-1-056 1#GC7-1003 Two 6/26/2002 1200001173 2001-1-059a 1#EB-12 Two 8/9/2002 1200001173 2001-1-059b 1#EB-12 Two 8/8/2002 1200103157 2001-1-060 1#CC5-1003,A7 One 7/16/2002 1200003361 2001-1-064a 1HVSI-709 One 8/9/2002 1200003361 2001-1-064b 1HVSI-710 One 8/9/2002 1200003361 2001-1-064c 1#CC14-1004 One 7/19/2002 1200100808 2001-1-069 1CV3938 Two 7/15/2002 1200100809 2001-1-070 1CV3939 Two 7/12/2002 1200103303 2001-1-072 1CKVFW-130 Two 7/18/2002 1200101396 2001-1-075 1RV200 One 7/18/2002 1200101398 2001-1-076 1RV201 One 7/18/2002 1200101781 2001-1-077 1PZVRX11 One 7118/2002 1200000999 2001-1-079 lCKVSI-114 Two 7/31/2002 1200000998 2001-1-080 1CKVSI-124 Two 7/12/2002 1200000997 2001-1-081 1CKVSI-144 Two 7/17/2002 1199802485 2001-1-082 lCKVSI-227 One 7/17/2002 1200103149 2001-1-083 1CKVSI-237 One 7/17/2002 1200103150 2001-1-084 lCKVSI-247 One 7/15/2002 1200002340 2002-1-002a 1CKVCVC-186 One 7/25/2002 1200002340 2002-1-002b 1#CC5-1004 One 7/19/2002 1200200048 2002-1-003 1#EB6-1007 Two 7/16/2002 1199804734 2002-1-009 1CKVFW-133 Two 8/8/2002 1200201261 2002-1-017 1SYS083 Two .7/19/2002 1200001375 2002-1-019a 1MOV4145 Two 8/8/2002 1200001375 2002-1-019c 1#HC3-1001,H13/RI2 Two 8/8/2002 1200201762 2002-1-024 1CV4150 Two 7/18/2002 S199601526 SG-1-001a 1HXRC1I1 One & Two 8/5/2002 S199601526 SG-1-001b 1#CC-1 One 811/2002 S199601526 SG-1-001c 1#DB-1/EB-1, -5 & -6 Two 8/1/2002 S199601526 SG-1-001d 1#CC-9, 1"& under One 8/1/2002 S199601526 SG-1-001e 1HXRC11SUP One & Two 8/1/2002 3199601526 SG-1-002a 1HXRC12 One & Two 8/1/2002 S199601526 SG-1-002b 1#CC-1 One 8/112002 S199601526 SG-1-002c 1#DB-1/EB-1, -5 & -6 Two 8/2/2002 S199601526 SG-1-002d 1#CC-9, 1"& under One 8/1/2002 S199601526 SG-1-002e IHXRC12SUP One & Two 8/1/2002 S199601526 SG-1-003 1#CC-9. 1"& under One 8/1/2002 SNUB POOL SNUB-0-002 *Snubber Pool 1, 2, & 3 6/21/2002 EPU Reference No. 2002-47-22-3292

FORM NIS-2 OWNER'S REPORT FOR REPAIR I REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASIME Code Section Xl

1. Owner: Calvert Cliffs Nuclear Power Plant, inc. - Date: -7115/2002-(name) 1650 Calvert Cliffs Parkway; Lusby,-MD 20657 Sheet I of 2 (address) . .. - ..--
2. Plant: '- -- C caIvert Cliffs-Nuclear-Power P]ant' __Uni (name)

R&R No. 98-1-186, MWO No. 1199701954 1650 Calvert Cliffs Parkway; Lusby, MD 20657 (address) - .- (P.O. no ,job noetc.) ,

D~it* Tye Code Symbol Stamp: N/A -.

-Calvert Cliffs Nuclear Power,Plant Dept.:- Tuth-oraioib*oa.r-P' N/A

3. Work Performed by: -Clet(ae (name) Author-izationtNoý.: N/A Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 SectionXI Class: One
  • - .=

(address)

4. Identification of System: SystemNumber 052 System Name: Safety Injection 5.(a) Applicable Construction Code and Class: ASME B16".5, 1968 Edition, Steel Pipe Flanges and Flanged Fittings NPS 1/2"-t 24"& Case N-10 (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition
6. Identification of Components Repaired or Replaced and Replacement Components: ASME Repaired, Code National Other (ear Replaced, or Stamped Name of Name of Manufacturers Iluilt Replacement Serial Number Board No. Identification (Yes or No)

Componet Manufacturer 1975 Repalred/Repi_ No Valve Velan Enginnering SN: 0039 NIA #1IA Reactor Coolant Loop Safety Injection Inlet Check Valve aced Co.

C 2002 Replacement No Velan Valve 404387 SN: 7557 N/A Disc, Velan, 12 In. 1500 lb. Check Disc Corporatlon Valve, ASME SA-182,Tp. F316, Drwg. 12124-0001, Item H3

7. Description of Work:

This plan was for rebuilding 1-CKVSI-217, and replacing valve disc.

8. Tests Conducted: Hydrostatice[] PneumaticZ Nominal Operating Pressure. Inservice' 0 Leakage: D Functional:[]

Pressure: N/.IA psi. Test Temperature: N/_.A Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

No Section XI Pre-Service NDE was performed in support of this activity. The replacement valve wedcqe/pluql/disc/trim received a Construction Code Surface Examination at the request of the resident ANII.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this RepalrlReplacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp. N/A Certificate of Authorization No.: N/A Expiration Date N/A Charles H Ballard Signed: Engineering Technician Date: 7/15/2002 S- Title

  • "Owned/oi*wn-er'sDesignee, Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components described in this Owner's Report during the period '- / - to , , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report m accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

1J3d2, Stat,7.'.En NatonlComissions: me Inspeco'/intr National Board, State~and Endorsements Date _ 200Z_

  • FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section XI 8 /1 2 /2. 0 0 2

-bL" ier- .~--Calvert Cliffs Nuclear Power Plant,-Inc.?, "-... b S. ~ ~(name) "", . .. . ,. . ',"

1650 Calvert Cliffs Parkway;m LusbyMD 20657 Sheet 1 of-2 (address)

Calvert Cliffs Nuclear Power Plant Unit: One

2. Plant:

(name)

R&R No. 2000-1-077a, MWO No. 1200001584 1650 Calvert Cliffs Parkway; Lusby, MD 20657 (address) (P.O no ,job no, etc.)

Type Code Symbol Stamp: .N/A

3. Work Performed by: Calvert Cliffs Nuclear Power-Plant Dept. -Authorization No.:- N/A

- (name)

Exp Date: N/A Section XI Class: One 1650 Calvert Cliffs Parkway, Lusby, MD 20657 (address) -

-4. Identification of System:" SystemNumber " 041 Sys'temName:

Name ystem Chemical Volume Conitrol -.

5. (a) Applicable Construction Code and Class: ASME Draft Code for Pumps & Valves, 1968 Edition, March 1970 Add; Class One- ._ ,.

(b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition

6. Identification of Components Repaired or Replaced and Replacement Components: ASME Repaired, Code Year: Replaced, oi Stamped Name bf Name of Manufacturers National , Other Serial Number Board No. Identification Built- Replacemen (Yes or No)

Componet Manufacturer JYi" epairewepi x es Valve Bechtel 2091-NI NIA N11 Regen. Heat Exch. Check Jyja .I RepaireduRepi Nes Valve to #11 Pressurizer Aux. ,aced Spray Valve, Check, 2 in. SA-182, Tp 1994 Replacement No 90585-GX SN: N/A Valve Velan Engineering Co. 951037-2 F1316, 2680 Ib.,Socketweld, Velan Dwg 12968-0138

7. Description of Work:

This plan was for the work that replaced 1-CKVCVC-1 85, #11 Regenerative Heat Exchanger Check Valve to

  1. 11 Pressurizer Auxiliary Spray.
8. Tests Conducted: Hydrostatic.r"] PneumaticcI Nominal Operating Pressure- Inservice" E] Leakage. RJ Functional E]

Pressure: 2250 psi. Test Temperature: 530 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 -(Back)

9. Remarks:

A Section Xl System Leakage Test of the affected component was performed during the system conditions listed in section 8. of this report. Code Case N-416-1 was invoked to satisfy Section Xl'required pressure tests. Addtional Section III Examinations were performed (as applicable) to satisfy Code Case N-416-1 and Recq.Guide 1.147.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this RepairlReplacement conforns to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H. Ballard Signed: Engineehiig Technician Date: 8/12/2002 Owner orOwner` ' Ttle Certificate of Iniservice Ins pection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components described in this Owner's Report during the period Z-- /3- _.Z-to d-- o - , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

S By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

_,26 4 -L n t g rt /1 3 8Z2 , AAJZ BCommissions:

S a E ld 9do eme InspNational Board, State, a~d Endorsements Da ,200-Z..

- C

  • DATA PACKAGE NO. 951037 P.6 FORM NPV-I.CER-I ICATE HOLDERS' DATA -REPO UCLEAR-PUMPS OR VALVES ,
1. Manufactured and certified by- VELAN INC. 2125 WARD AVE, MTL. CANAA -A (name and address of N Certficate Holder) . * .-
2. Manufactured for -',BALTIMORE GAS & ELECTRIC 'P.O. BOX 1472 BALTIMOREyMD. -21203 .

(name and address of purchaser) .

3.--Locati-on of-nstaliio-n CALVERT CLIFFSNUJCLEAR PLANT NORTH OF LUSBY, MD. 20657 S.. ...... .. ~~~~~(name and address). .. . . ... . . . ...

4. Model No., Series No., or Type: PS.CHECK Drawing P1-76800-N28 Rev D CRN N/A S.-ASME Code, Section III, Division 1: . 1989 ------- NONE 1 N/A (edition) (addenda date) (class) (Code Case no
6. Pump or valve VALVE Nominal inlet size 2" Outlet size 2"
7. Material:-Body--SA-182,F316- Bonnet SA-182;*F316"-Disk- COLMONOY 4 Bolting-_NA..

- (a) -... . (b) - (c) (d) - (e)

Cert. Nat'l -. Body *' Bonnet Disk Holder's Board - - -Serial ;Seri al. .- -Serial

-Serial No.- ,No -.- - No. No.- - No. -

-1 1 - I I 951037-1 N/A H/C: CH H/C: 1lARA ". 'H/C: 2072 951037-2 It - _ t 951037-3 '7 It

= =-~=====- .

- It I F -* ,

Supple-menal information in form of listsa,-sketche~s, or drawings rra*, be used provided (1) size is 8 112 x 11., (2) inform'ation in item's I thruough 4 on this-Data Report is included on each sheet, (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12188) This form (E00037) may be obtained from the Order Dept., ASME, 22 LAW DRIVE< BOX 2300 Fairfield, NJ 07007-2300.

FORM NPV-1 (Back-- Pg. 2 of 2 ) 7 - -. P.7-,

8. Design- conditions 6430 psi 100 OF or valve pressure class 2680 (1)

(pressure) (temperatuire 9.-Cold working pressure --- -- 6430- psir at 100*F.

10. Hydrostatic test 10050 psi. Disk differential test pressure 7375 psi
11. Remarks: MATERIALS MEET ASME SECTION II EDITION: 1989 ADDENDA: NONE CERTIFICATE OF DESIGN Design Specification certified by J.M. FARREL P'.E. State QUE Reg. no. 30039 Design report certified by S. ISBITSKY P.E. State CUE Reg. no. 22115 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this piump or "

valve conforms to the rules for construction of the ASMECode,Section III, Division 1.

N Certificate of Authorization-No. N-2797-1 M 2,98 Date MAY 2 6 1995 Name VELAN INC. Signed

-. ~(N Certificate Holder) (aubo resematve)

"CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of QUEBEC and employed by PROVINCE of QUEBEC have-inspected the pump, or valve, described in this Data Report on Y,(-e-l/- , and state that-to the best of my knowledge and belief, the Certificate Holder has constructed this pump, or valve, in accordance with the ASME Code, Section-III, Division 1.

By signing this certificate, neither the inspector nor his employer makes any warrenty, expressed or implied, concerning the component described in this Data Report.

Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Date 9S- O.- signed7s S(Nat'l. --< omisn state or Bd.

prov.(inc.

and endorsments) no.) and (1) For manually operated valves only. PAYMON. LAUZON

  • G'. -U EATJ]YENT Du OUt1EC

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section XI

1. Owner: -Calvet Cliffs-Nuclear-Power Plant, Inc.' Date:- 81812002. " "

(name)

Q:h~a t ,*f 0 IrJU %AjIVtIL a-1I11I r CalIFVV43, - "

- ,.: , ": " .'-(address)s ., -- -.

-, -- , . -,Calvert Cliffs -NucledrPd*er Plant .... .t-. -One 0 '  ;-e.

--II'59 iClvertcliffs Pa.rkway-; Lusby,-MD 20657 R&R No. 200b:1'l-d4,;'MWO No:,1200O01460 -:--,

(address) - (P.O. no ;job no, etc.)

3. -Work Performe-* by: -Calvert- ~~(name) Cliffs Nuclear-Power Plant Dept Type.Code Synb Stamp: N/A -

-Wr Proreib.thorizationiNo6:: (nme _ N/AK-Exp Date: N/A 1R165 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class: One

,- . .. (address)

-4. Identification of System: System Number 064 SystemName: Re actor-Coolant Systemi . .

5.(a) Applicable Construction Codeand Class: ASME B31.1.0 1967.Editioni CCases N-2,-N-1 0 -"_..'- - - ,

1998 Edition -- , -

--(b) Applicable Sect XI Ed. for Repairs/Replacement

6. Identification of Components Repaired or Replaced and Replacement Components: ASME Repaired, Code National "Other Year -Replaced, o0'Stamped Name of Name of Manufacturers Serial Number Board No. Identification Built "Replacemen (Yes or No)

Componet Manufacturer -

RepaIred/Rep! No 69-4126-001 N/A # IA Pressurizer Spray Control 1975 Repaired/Repl No Valve ITT Hammel Dahl - aced Valve 2000 Replacement Flowserve 400322 SN; D909A NIA Bonnet, Bellows, 3 In. 1500 lb. No Bonnet Corporation 1-2 ITT Hammel-Dahl Angle Valve, Drwg. #12121-0006, Item #2 1996 Replacement 10486-GX Heat - N/A Cap, Pipe, 112 in., 3000 lb. SW, No Pipe Cap DuBose National Code: HTK ASME SA-182, Tp. 316 Energy Services Inc.

1993 Replacement No Plug Neles Jamesbury 82350-GX Ht. N/A Plug for 3 in. 1500 lb. ITT

  1. B7722H Hammel-Dahl Angle Valve, Drwg.
  1. 12121-0006, Item #6
7. Description of Work:

This plan was for the rebuilding and replacement of the Bonnet and Plug on 1-CV-1ODE, which is #11A Pressurizer Spray Control Valve.

Pneumatic Nominal Operating Pressure- Inservice. 0 Leakage: R Functional:[]

8. Tests Conducted: Hydrostatic:"]

psi. Test Temperature: 530 Deg. F Pressure: 2250 NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in Items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

I Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section XI System Leakage Test of the affected component was performed during the system conditions listed in section 8. of this report. A Section XI Surface Examination of the affected component was performed to satisy SectioriXI Pre-Service Requirements.

Applicable Manufacturer's Data Reports to be Attached

-- -. . .. "- .... ert ate ofComphance .... "

We certify that the statements made in this report are correct and that this RepiirIReplacement conforms to the rules ofthe ASME Code, SectionXI ..... ,....

- Type Code Symbol Stamp:- -N/A.. .

Certificate of Authorization No.: N/A Expiration late: N/A Charles H. Ballard Signed: Engineering Technician Date: 8/8/2002 Oner's Designee, Title Certificate'of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components descnbed in this Owner's Report during the period iZ-/7-t0/ to 7-/1 1*,i02- , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described m this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

Commissions: -- l Inspector'Signature National Board, State, and Endorsements Dat x 1 . 200 _-

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions o'f the ASME Code Section XI Calvert Cliffs Nuclear Power Plant, Inc. Date:- .719/2002

1. Owner:

(name) 1650 Calvert Cliffs Parkway;, Lusby, MD, 20657 Sheet 1 of 2

.(address).. -

2. Plant: Calvert Cliffs Nuclear Power Plant. Unit: . One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2001-1-010, MWO No. 1200005063 (address) (P.O. no ,job no., etc.)

Type Code Symbol Stamp: N/A

3. Work Performedby: Calvert Cliffs Nuclear Power Plant Dept. Authorization No.: N/A (name)

Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657, Section XI Class: One (address)  ;: - I

4. Identification of System: System Number 052 SystemName: Safety Injection
5. (a) Applicable Construction Code and Class: ASME B31.1.0 1967 Edition, CCases N-2, N-10 (b) Applicable Sect XI Ed. for Repairs/Replacement .1998 Edition
6. Identification of Components Repaired or Replacediand Repla~cement Components: "- . . ASME Repaired, Code I Name of Name of. Manufacturers, National - ... Other Year Replaced, oi :Stamped' Componet Manufacturer Serial Number Board No. Ideritification . Built Replacemen (Yes or No)

Valve ITT Hammel-Dahl H5624 N/A #11A Safety Injection Tank, - 1974 Repaired/RepI No Reactor Safeguards Check Valve acedmen leakage drain CV to R.W.T.

N/A Plug & Stem Ass. 1 In. 1500 lb. 2000 Replacement No Plug Assembly Flowserve 400322 Ht.#: 724770 Corporation ITT Hammel-Dahl Unbalanced Globe Valve, Drwg. #12121-0013, ,

Item #6

7. Description of Work: ....... .... .

This plan was for the rebuilding of 1-CV-618, #11A Safety Injection Tank, Reactor Safeguards Check-Valve leakage drain to R.W.T.

Pneumaticl] Nominal Operating Pressure: Inservice: M Leakage. E] Functional E]

8. Tests Conducted: Hydrostatic.[]

Pressure: N/A psi. Test Temperature: N/A Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in Items 1through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

No Section Xl Pre-Service NDE was performed in support of this activity. The replacement valve wedge/plug/disc/trim received a Construction Code Surface Examination at the request of the resident ANII.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Repalr/Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A SCharles H. Ballard Signed: _Engineering Technician Date: 7/19/2002

¢"'Owner or Owner's Disifne, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components described in this Owner's Report during the period /.-/O-'/ to G--2.) -Q') .. and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

XCommiissions:

Im~pbs-SignaureNational /23 e8Z2-rfBoard, State,)and fndorsements

-AJ AI1 W-67 Date:*:LZ_ 2002_

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section XI

1. Ownr:
  • Calvert Cliffs Nuclear Power Plant, Inc. "Date: -"7/19/2002 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 - Sheet 1 of 2 S..(address)

.'2.-Plant' ',Calvert Cliffs Nuclear Power Plant Unit: One ,. _ -,u-;-- -

(name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2001-1-011, MWO No. 1200005064 (address) (P.O no ,job no, etc)

Type Code Symbol Stamp: N/A

3. WorkPerformedby. Calvert Cliffs Nuclear Power Plant Dept. Authorization No.: N/A (name)

Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class: One (address)

4. Identification of System: System Number 052 .,SystemName: Safety Injection 5.(a) Applicable Construction Code and Class: ASME B31.1.0 1967 Edition, CCases N-2, N-10 (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition
6. Identification of Components R6epaired or Replaced an'd Replacement Components: ASME "Repaired, Code Name of Name of, Manufacturers National Year Replaced, oi Stamped Componet Manufacturer Serial Number,' Board No. "Identification Built Replacemen (Yes or No)

Valve ITT Hammel-Dahl SN: 83839D1A004 N/A #11B Safety Injection Tank, 1974 Repalred/Repl No Reactor Safeguards Check Valve aced leakage drain CV to R.W.T..

Plug Assembly Flowserve 400322 H1.#: 724770 N/A Plug & Stem Ass. 1 In. 1500 lb. 2000 Replacement No Corporation , - ý I ITT Hammel-Dahl Unbalanced Globe Valve, Drwg. #12121-0013, Item #6

7. Description of Work:

This plan was for the rebuilding of 1-CV-628, #11 B Safety Injection Tank, Reactor Safeguards'Check Valve leakage drain to R.W.T.

8. Tests Conducted- Hydrostatic--] Pneumaticl" Nominal Operating Pressure. Inservice: [J Leakage: E] Functional: E]

Pressure: N/A psi. Test Temperature: N/A Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

X-Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

No Section XI Pre-Service NDE was performed in support of this activity. The replacement valve wedcqe/pluqldiscltrim received a Construction Code Surface Examination at the request of the resident ANII.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance.

We certify that the statementf made in this report are correct and that this RepalrlReplacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: NIA Certificate of Authorization No.: N/A Expiration Date: N/A

        • S*/Charles H. Ballard Signed: Engineering Technician Date: 7/19/2002 Owner or Owner's Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components described in this Owner's Report during the period /.-/d -0/ to S-e..7-O7_ , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

(i Inspector's Signature

~ ~~~Commissions: Atý'822c6,+A 1 'z ,,1~~*

National Board, State, and Endorsements DteS 200 -..

I/

FORM NIS-2 OWNER'S REPORT FOR REPAIR I REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xl

1. Owner: "--Calvert Cliffs Nuclear Power Plant, Inc. --Date: -711912002 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 "SheetI of 2

........... - (address)-- -. . .. .

2. Plant: ----Calvert Cliffs Nuclear PowerPlant: -- Unit: - One *- , -

(name) -

1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2001-1-012, MWO No. 1200004019 (address) -, (P.O no., job no., etc )

Cliffs Nuclear Power Plant Dept.

Calvert (Authorization -Type Code Symbol Stamp: N/A

3. Work Performed by: No.: N/A (m-- , , -ExpDate:'N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 \SectionXI Class: One (address)
4. Identification of System: System Number 052 System Name: Safety Injection 5.(a) Applicable Construction Code and Class: ASME B31.1.0 1967 Edition, CCases N-2, N-10 (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition
6. Identification'of Components Repaired or Replaced ard Replacernent Components: -f -

S" ASME Repaired, , Code Manutacturers INational u.ner Siear "Replaced, oi Stamped Name of I Name of .Built Replacemen (Yes or No)

Componet 'Manufacturer Serial Number Board No. Identification Valve ITT Hammel-Dahl SN: 83839-005 N/A t#12A Safety Injection Tank, 1974 Repalred/Repi 'No Reactor Safeguards Check Valve acedc leakage drain CV to R.W.T.

400322 Ht.#: 724770 N/A Plug & Stem Ass. 1 In. 1500 lb. 2000 Replacement No Plug Assembly Flowserve Corporation ITT Hammel-Dahl Unbalanced Globe Valve, Drwg. #12121-0013, Item #6

7. Descnption of Work:

This plan was for the rebuilding of the #12A Safety Injection Tank, Reactor Safeguards Check Valve leakage drain 1-CV-638 to R.W.T.

8. Tests Conducted: Hydrostatic:[] Pneumatic'] Nominal Operating Pressure: Inservice- ] Leakage:E] Functional LI Pressure: N/.._A psi. Test Temperature: N/A Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

No Section Xl Pre-Service NDE was performed in support of this activity. The replacement valve wedqe/pluQfdisc/trim received a Construction Code Surface Examination at the request of the resident ANII.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance _

We certify that the statements made in this report are correct and that this -Repair/Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H. Ballard Signed: N Engineering Technician Date: 7/19/2002 Owner or Owneres De'indr Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components described mnthis Owner's Report during the period /2-10 -6/ to S--_.)- . , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

Ieos SinaueNtoaBarComEissions: AAor>

Inspe ~or's Signature National Board, State, and Endorsements Date Z5 200.Z-

/6/

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of tIhe-ASME Code Section XI

1. Owner: CalVert Cliffs-N'uclear Power Plant, Inc.

§'- -.Date: -, 711912002 (name)

,- Sheet 1 of 2 1650 Calvert Cliffs Parkway; Lusby, MD 20657.

(address)

,,L. r,=.:'  :-- Calvert Cliffs Nuclear Power Plant --_Unit: "* One ri .L" (name) ...

R&FZ No. 2001-1-013, MWO No. 1200005065 1650 Calvert Cliffs Parkway; Lusby, MD 20657 (P 0. no ,job no, etc.)

(address)

Type Code Symbol Stamp: N/A

3. WorkPerformedby: Calvert Cliffs Nuclear Power Plant Dept. Authorization No.: N/A (name)

"1Exp Date: N/AA Section XI Class: One 1650 Calvert Cliffs Parkway, Lusby, MD 20657 (address)

System Number 052 SystemName: Safety Injection

4. Identification of System:
5. (a) Applicable Construction Code and Class: ASME B331.1.0 1967 Edition, CCases N-2, N-1 0 1998-Edition (b) Applicable Sect XI Ed. for Repairs/Replacement
6. Identification of Components Repaired or Replaced and Replacement Components:! Yer

- Repaired, ASME Code

-National 'Other --yer -Replaced,ol "Stamped Name of _Name of Manufacturers Serial Number Board No. Identification "Built Replacemen (Yes or No)

Componet Manufacturer Valve ITT Hammel-Dahl 1-CV-648 N/A '112B Safety Injection Tank, - 1974 Repalredr*ep,

-aced ' 'N, Reactor Safeguards Check Valve leakage drain CV to R.W.T.

Replacement No N/A Plug & Stem Ass. 1 In. 1500 lb. __ 2000 Plug Assembly Flowserve 400322 Ht.#: 724770 ITT Hammel-Dahl Unbalanced Corporation Globe Valve, Drwg. #12121-0013, Item #16

7. Description of Work:

Valve This plan was for the rebuilding of 1-CV-648, #12B Safety Injection Tank, Reactor Safeguards Check leakage drain to R.W.T.

Pneumatic] Nominal Operating Pressure. Inservice" I] Leakage: El Functional: El

8. Tests Conducted: Hydrostatic']

Test Temperature: N/_A Deg. F Pressure: N/_A psi.

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

is numbered and the (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

No Section X1 Pre-Service NDE was performed in support of this activity. The replacement valve wedge/plug/disc/trim received a Construction Code Surface Examination at the request of the resident ANJI.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Repalr/Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A Signed:

7/JI Charles H.Ballard Engineering Technician Date: 7/19/2002 Owner or Ownirs Lresignee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components described in this Owner's Report during the period / 2--/A -0) / to --0 2 , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

s S o ssiont Naýonal oaZr, 4xa-:r and*do4re Inspecto/s Signature National Board, State, and Endorsements Date: L4,+.ZS- 200 Z.

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section XI

1. Owner: Calvert Cliffs Nuclear Power Plant, Inc.- Date: 711712002 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet I of 2

. .. (address)

2. Plant: Calvert Cliffs Nuclear Power Plant- unit: -One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2001-1-017, MWO No. 1200101169 (address) (P.O. no ,job no., etc)

Calvert Cliffs Nuclear Power Plant Dept. Type Code Symbol Stamp: N/A

3. Work Performed by:

(name) Authorization No.: N/A Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 . Section XIClass:_ - One (address)

4. Identification of System: SystemNumber 052 SystemName: Safety Injection
5. (a) Applicable Construction Code and Class: ASME B&PV Code Sect. Iii, 1971 Edition, Class One (b)Applicable Sect XU Ed. for Repairs/Replacement " ,1998 Edition
6. Identification of Components Repaired or Replaced and Replacement Components: ASME

'Repaired, -Code Name of Name of Manufacturers National Other Year 'Replaiced, oi Stamped Componet' Manufacturer, Serial Number- B6oad No.' Identification Built Replacemen (Yes or No)

Valve Crosby Valve & SN: N55296-01-0032 N/A:' Shutdown'Cooling Containment - - 1973 Repaired/Repl Yes Gage Co. Side Return Header Relief Valve aced+

Valve, Relief BGE CCNPP Shops 1199804699 SN: N/A Valve, Relief, Nozzle Type, 3/4 In. 2000 Replacement Yes N55296-01-0009 X I In., Style JR-WR-S Type B,-- -

Item on Drwg.#12791-0007.

"Unlt#1

7. Description of Work:

This plan was for-the replacement of 1-RV-469 which is the Shutdown Cooling Containment Side-Return i Header Relief Valve.

8. 'Tests Conducted: Hydrostatic-[] PneumaticOl Nominal Operating Pressure: Inservice: El Leakage: 2 Functional:E]

Pressure: 4 psi. Test Temperature: 83- Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

I-Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section Xl System Leakage Test of the affected component was performed during the system conditlons listed in section 8. of this report.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this RepairlReplacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H. Ballard Signed: Engineenng Technician Date: 7/17/2002 Owner or Owner's'Desgn ee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components described in this Owner's Report during the period 6,- /-OL to ,-.ZS-CZ..- , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

)t aNtnoCommissions: A/-3 aAZ E1ren4 St ae' '

Inspector Srigature National Board, State, adtd Endorsements Date:G " I 200 Z.

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section XI

1. Owner:

Calvert Cliffs Nuclear Power Plant, Inc. Date: 711512002 (name),

1650 Calvert Cliffs Parkway; Lusby, MD 20657 -- . Sheet I of 2 .

- - - - (address)

2. Plantm SCalvert Cliffs Nuclear Power Plant Unit: . One I (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2001-1-027, MWO No. 0199902341 (address) i I (P.O no job no, etc)
3. Work Wr Performed efre by:Calvert y Cliffs Nuclear Power Plant D ept. Type Code Symbol Stamp: N/A Authorization No.: N/A (name)

"EcpDite: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XIClass: Two (address) .~ _ ,

4. Identification of System: SystemNumber 083 -System Name: Main Steam & SG Blowdown I I -

5.(a) Applicable Construction Code and Class: ASME B31.1.0 '1967 Edition, 1972 Add (b) Applicable Sect XI Ed. for Repairs/Replacement *. 998 Edition

6. Identification -fComporiehts Repaired or Re'placed and Replacement Cornponents-: ASME

-. Repaired, Code Year Replaced, or Stamped Name of Name of - - - Manufacturers - National -

  • Other.

Built Replacement (Yes or No)

Componet - Mafiufacturer -. Serial Number Board No. - Identification Pipe Support Bechtel 1#EB-6-1008,RS & N/A #12 Steam Generator Bottom 1975 Repaired/Repl No H30 Blowdown Piping I aced

7. Description of Work:

This Repair Plan was for the work that was required to correct a problem that was dicovered between an as built and an as analyzed state of 2"EB-6-1008, which isthe #12 Steam Generator Bottom Blowdogvh Piping:

Because of these findings, it was necessary for the supports at location 30 and location 5 be corrected to match design doc.FSK-MP-0655 REV. 10.

8. Tests Conducted: Hydrostatic:[-] PneumaticS] Nominal Operating Pressure: Inservice [] Leakage: [] Functional LI Pressure: N/.A psi. Test Temperature: N/A Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

No Section XI Pre-Service NDE was Performed in support of this activity.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Repair/Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H. Ballard Signed: Engineering Technician Date: 7/15/2002 Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components descnbed in this Owner's Report during the period &-/1 -01 to S,--"Z.- , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described m this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

A 4&aCommissions: Boar, SteJ, a P*nr 92e7t sp~tes e ýNational iv~treý Board, State, and t~ndorsements; S~200 Z..

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xl

1. Owner: - Calvert Cliffs Nuclear Power Plant, Inc., -Date. 7/19/2002 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet 1 of 2 (address)
2. Plant: Calvert Cliffs Nuclear Power Plant Unit: One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 "RFi&R No. 2001-1-0228, MWO No. 1200002465 (address) (P.O. no ,job no, etc)

Dept. Type Code Symbol Stamp: N/A

3. Work Performed by: Calvert Cliffs Nuclear Powerr Plant Auth6rization No." N/A (name)

Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class: Two (address)

4. Identification of System:' SystemNumber 083,- SystemName:' Main Steam & SG Blowdown 5.(a) Applicable Construction Code and Class: ASME Draft Code for Pumps & Valves, 1968 Edition, March 1970

-Add; Class Two, CCase 1427 A,

4 -1998 Edition (b) Applicable Sect XI Ed. ,for Re'pairs/Replacement

6. Identification of Components Repaired or Replaced and Replacement Components: ASME Repaired, Code Name'of Name of Manufacturers National - . th er "Year Replaced, oi, Stamped Manufacturer Serial Number Board No. Identification Built -ReplacemenT (Yes or No)

Componet 1268 N/A' - #11 Steam Generator - - - -.- " 1975 Repaired/Repi No Valve Velan Englnnering

.-Atmospheric Dump Manual aced Co.

Isolation Valve

7. D'escription 6fWork: - .. ,, .... "

This plan was for the replair work to the steam cUtsthatManual were on the sealing surfaces Iof the bonnet of 1 Isolation Valve'. -

HVMS-101, #11 Steam Generator Atmospheric Dump

8. Tests Conducted: Hydrostatic-- Pneumati- l Nominal Operating Pressure: - iseirvieI l Leakage: Funtional ..

Pressure: 880 psi. Test Temperature: 530 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in Items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section XI System Leakage Test of the affected component was performed during the system conditions listed in section 8. of this report. Code Case N-416-1 was invoked to satisfy Section XI required pressure tests. Addtional Section III Examinations were performed (as applicable) to satisfy Code Case N-416-1 and Re-g.Guide 1.147.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Repair/Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A SACharles H. Ballard Signed: Engineenng Technician Date: 7/19/2002

'~Owner or Ow-niers Dfi-inee, titl Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components described in this Owner's Report during the period 6-/0-0/2 to 7-/17-0 Z. , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section X.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

nspectors S/naurNtn Commissions: /, St and EdrZ ments Inspector's Signature National Board, State, and 6dorsemnents Date2 200 Z-

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section XI

.-Calrert Cliffs Nuclear-P6wer P lant, Inc. - -- Date' -- 8/812002 -

"(name) . ...-- -  :  :- -. -

1650 Caliv'ert Cliffs Parkway; Lusby, MD 20657: . Sheet I f2 - -6 (address)

2. ;Pan"" -Calvert-Cliffs Nuclear Power Plaht OUnitn:.One -

(name)~---------------

1650 Calvert'Cliffs Parkway; Lusby, MD 20657 R&R No. 2001-1-031a. MWO No. 1199900767

""-(address) (P.O. no ,job no, etc)

Calvert Cliffs Nuclear Power Plant Dept.-- Type Code Symbol Stamp: N/A
3. Work Performedb PefrmAuthorization

'," - - ~ (n~~~(name) ame) " , -- , No.: --N/A - ,

Exp Date" N/A:

1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class: Two

-(address) .. .. . . "

4. Identification of System: SystemNumber 052 - SystemName: Safety_ ectin"

5.(a) Applicable Construction Code and Class: ASME B&PV Code Sect. III, 1989 Edition, Class One (b) Applicable Sect XI Ed. for Repairs/Replacement °1998 - Edition

6. Identification of Components Repaired or Replaced and Replacement Components: -. ASME Repaired, Code National "Other Y'ear Replaced, oi Stamped Name of N Name of Manufacturers -"

Board No. -Identification "' 'Built Replacemen (Yes or No)

Comnponet Manufacturer Serial Number N/A #13 TIPSI Pumlp Mini Flow 1991 Repaired/Repl Yes Valve Velan Englnnering 1568 -.... aced - -

Isolation Valve Co.'

1994 Replacement - Yes 90585-GX SN: N/A ,Valve, Globe, 2 In, 1690 lb.,

Globe valve ' Velan Engineering ASME SA-182 Tp. F316, per Co. 941143-2 Drawing 12968-0134, Item 129.

7. Description of Work: .

This plan is for the replacement of I-HVSI 425, #13 HPSI Pump Mini Flow Isolation Valve.

8. Tests Conducted: Hydrostatic E] PneumaticZi] Nominal Operating Pressure: Inservice. ED Leakage. R Functional LI --

Pressure: 1300 psi. Test Temperature: 8.2 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section Xl System Leakage Test of the affected component was performed during the system conditions listed in section 8. of this report. Code Case N-416-1 was invoked to satisfy Section XI required pressure tests. Addtional Section III Examinations were performed (as applicable) to satisfy Code Case N-416-1 and Reg.Guide 1.147.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Repalr/Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H. Ballard Signed: Engineering Technician Date: 8/8/2002 Owner or Ownrs Dsgnee,Tie Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components described in this Owner's Report during the period ,/6-ZV- to 7- / 7-d Z.- , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

&Commissions: A1 LA 2Z ,&4 4/A.'- A6 K4ý'

Inspector's Signature National Board, State, Snd Endorsements Da2e 2O0

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section XI

. Owner:: .. . Caliert -. CliffsNuclar Pcwe-r P , ---

-lantnc.

.-- Date .81812002

-- - . ,* '-"  :,-- - .` (name) - - - -- -. . . . . " - .t-. .. - .4,

-i . - .- -

1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet I of 2

. . . P aalvt e - rt .CCh ff s uce a r P ow e-r-P la n t . .. . . . n - .. . .

-- "-2. Plant:Z~ C. v  ;-- nt..-ne< 17:

-.... .. . . --.. (name) .- -

1650Calvert Cliffs Parkway;-Lusby, MD 20657 R&R No2001--31b MWO No. 1199900767 -

(address) _ - (P.O. no., job no, etc)

"-"Calvert Cliffs Nuclear Power Plant Dept. -e .. .b

-Type- Stamp: NIA

3. Work Performed by. Authorization No.: N/A

- (name) -

Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class: Two

-- L. . . (address) -.. . ,

4.' Identification of System: SystemNumber. 052 - :SystemNaie": -"-'Safety Ifijection 5.(a) Applicable'Construction Code and Class: ASME B331.7- 1969 Edition; Summer 1971 Add; Class Two, - -.

(b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition ASME

6. Identification of Components Repaired or Replaced and Replacement Components: -

Repaired, Code Manufacturers National Other 'Year Replaced, ot Stamped Name of Name of Built "Replacemen (Yes or No)

Serial Number Board No. Identification Componet Mamifacturer No 2"DC-2-1003 - N/A #13 HPSI Pump Mini Flow'piping " 1975 Repaired/Repl No Piping System Bechtel aced Pipe Sa'ndvik Steel Inc. F-5630 Heat#496481 N/A -Pipe, 2 in. Sch. 80, Stainless Steel, 1977 Replacement No SA-376, TP-304 54906-GX Heat Reducer Insert, 2 in. X 1 in., 1992 Replacement No Reducing Insert DuBose National Code: FTY 30001b, Socketweld, SA-182, F304 Energy Services Inc.-

Coupling, 2 in., 3000 lb.,ASME 1992 Replacement No Coupling DuBose National 54906-GX Heat Code: FUY SA-182, Tp. F304, Socketweld Energy Services Inc.

7. D eiscript-ion of Work:

This plan was for the support work and material needed to replace I-HVSI 425, #13 HPSI Pump Mini Flow Isolation Valve.

Pneumatics] Nominal Operating Pressure: Inservice" [] Leakage:2] Functional:f]

8. Tests Conducted: Hydrostatic [

Pressure: 1300 psi. Test Temperature: L2 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section Xl System Leakage Test of the affected component was performed during the system conditions listed in section 8. of this report. Code Case N-416-1 was invoked to satisfy Section XI required pressure tests. Addtional Section III Examinations were performed (as applicable) to satisfy Code Case N-416-1 and Re-q.Guide 1.147.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Repalr/Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A

~ Charles H. Ballard Signed: ~ 4JEngineering Technician Date: 8/8/2002 Owner or Owner's 1-*eignee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components described in this Owner's Report during the period /- - to 7-/ 7-0 Z- , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

"k ý In to'sgt Commissions- AIR ona aAS.Z, nd Edrmn6 Inspectlor's Signature National Board, State, and Endorsements Date 200 7-

FORM NIS-2 OWNER'S REPORT FOR REPAIR I REPLACEMENT ACTIVITY As Required Required by the Provisions of the ,ASME Code Section XI Calvdrt'Cliffs Nucilear'Power Plant, Inc. "Date: 7/3112002. ""

".-Ow"er:'

"(name)

Sheet1 lof 2 "1650Calvert Cliffs Parkway; -Lusby, MD- 20657:

- Calvert Cliffs Nuclear Power Plant - Unit:" One"

2. Plant: .

(name) 1650'Calvert Cl'iffs Parkvv`y; Lusby, MD -20657 R&R No. 2001-1-042, MWO No. 1200103259 (address) _, (P.O. no ,job no , etc.)

Type Code Symbol Stamp: N/A

3. Work Performed by: Calvert Cliffs Nuclear Power Plant Dept. Authorization No.: N/A (name)

Exp Date: N/A Section XI Cla ss: One 1650 Calvert Cliffs Parkway, Lusby, MD 20657 (address) . -. .

-4.-Identifiition'ofSystem:. SystemNumber 064 .SystemName: Reactor Coolant System 5.(a) Applicable Construction Code and Class: ASME B&PV Code Sect. III, 1983 Edition, Summer 1983 Add; Adc e" 1998 Edition (b) Applicable Sect XI Ed. for Repairs/Replacement 199....io

6. Identification 6f Components Repaired or Replaced and Replacement Components: ASME Code

'Repaired, Year Replaced, oi Stamped

-Name of Name of Manufacturers. National , Other Board No. Identification Built Replacemen (Yes or No)

Componet Manufacturer Serial Number Repaired/RepI Yes RCP Seal Sulzer Bingham IC866 NB 1238 #11AReactor Coolant Pump 1988 "Repaired/Repi aced Yes Inc. Mechanical Seal.

2000 Replacement Yes

_BGE CCNPP Shops 1199700104 SN: NB 1239 Seal, Cartridge Assembly (RCP)

Seal

-" 1C872 "875B-3VComplete Sulzer Blngham per FCR87-0074

7. Description of Work:

This- plah Was for the-replacementof the mechanical seal on #11 A ReactorCoolant Pump.-

8. Tests Conducted: Hydrostatic'- Pneumatic[ Nominal Operating Pressure: Inservice: [] Leakage:&] Functional:E]

Pressure: 2250 psi. Test Temperature: 530 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

_______________________ - I Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section Xl System Leakage Test of the affected component was performed during the system conditions listed in section 8. of this report.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this RepalrlReplacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A

    • 'e I Charles H. Ballard Signed: c Engineenng Technician Date: 7/31/2002 ner or Owner's Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components described in this Owner's Report during the period c5-/ 4/-dl to 7-/1-O2- , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures descnbed in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

" -- t - inaCommissions: Natna Bard . ,n Edrm

ýn~s~to~s SgnaureNational Board, State, 'and Endorsements S y 7 200 Z.

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xl

1. Owner: Calvert Cliffs Nuclear Power Plant, Inc. Date: 711712002 '

- -(name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet I of 2 (address)

2. Plant: Calvert Cliffs Nuclear Power Plant Unit: One (name) ,

R&RNo. 2001-1-047, MWO No. 1200002904 1650 Calvert Cliffs Parkway; Lusby, MD 20657 (address) (P.O no ,job no, etc)

3. Work Performed by: Calvert Cliffs Nuclear Power Plant Dept. Type Code Symbol Stamp: N/A Authorization No.: -N/A (name)

"ExpDate: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class: Two (address) '

4. Identification of System: System Number 052-1 SystemiName: -.SafetyI njection 5.(a) Applicable Construction Code and Class: ASME B31.7 1969 Edition, Summer 1971 Add; Class Two (b) Applicable Sect XI Ed. for Repairs/Replacement '1998 Edition
6. Identification of Components Repaired or Replaced and Replacement Components: I -- A SM E Repaired, Code

-Manufacturers' -'National Other Year Replaced, oi Stamped Name of Name'of Serial Number Board No. Identification 'Built Replacemen (Yes or No)

Componet ' Manufacturer No Piping System ' Bechtel 2"GC5-1008 N/A Shutdown Cooling Header Vent 1975 Repaired/Repl No Assembly aced Energy & Process 99 883-GX Ht# N/A Pipe, 2 ln. Sch.40, ASME SA- .1995' Replacement No Pipe Corporation 438523 376, TP-304 549006-GX Ht# FNJ N/A Reducer, Insert, 2" X 3/4", ASME 1992 Replacement No Reducer, 2" X DuBose National SA-182, F304, Socket Weld,  %--

3/4" Energy Services Inc. #3000, Class 1,ANSI B16.11, .

- 11992 -Replacement " No Tee, 2", SA-182 'DuBose National 549 06-GX Ht# NN NIA Tee, 2", ASME SA-182, F304, Energy Services Socket Weld, #3000, Class 1, Inc. ANSI B16.11

7. Description ofWork:---

This plan was for the installation of a new Shutdown Cooling Header Vent/Valve Assembly on the'2" GC-5 1008.

8. Tests Conducted: Hydrostatic.] Pneumatic] Nominal Operating Pressure Inservice: E] Leakage W Functional: L Pressure: 102 psi. Test Temperature: .8 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section Xl System Leakage Test of the affected component was performed during the system conditions listed in section 8. of this report. Code Case N-416-1 was invoked to satisfy Section Xl required pressure tests. Addtional Section III Examinations were performed (as applicable) to satisfy Code Case N-416-1 and Req.Guide 1.147.

Applicable Manufacturer's Data Reports to be Attached We certify that the statements made inCertificate of Compliance this report are correct and that this Repair/Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H. Ballard Signed: Fe- Engineenng Technician Date. 7/17/2002 Owner or Owners Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components described m this Owner's Report during the period Z6 - / - Q / to ' -- '- 0?- , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report m accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, conceming the examinations and corrective measures described m this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

Commissions: , AA21A.)

t "

ns ure National Board, Statt, and Endorsements S200 L.

FORM NIS-2 OWNER'S REPORT-FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the AS ME Code Section XI

1. Owner:

Calvert Cliffs Nuclear Power Plant, Inc. Dat: 8/1512002 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 - Sheet I of 2 (address) .. . .

2. Plant: "CalvertCliffs Nuclear Power Plant Unit: One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2001-1-049, MWO No. 1200003521 (address) (P.O. no.,job no,etc.)

"-Type Code Symbol Stamp: N/A

3. Work Performed by: Calvert Cliffs Nuclear Power Plant Dept. Authorization No.: N/A (name)

,Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class: - One (address) - -

4. Identification of System: _System Number - 064 SystemName: Reactor Coolant System 5.(a) Applicable Construction Code and Class: ASME B&PV Code Sect. III, 1983 Edition, Summer 1983 Add;

-.Class One -.....

(b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition

6. Identification of Components Repaired or Replaced and Replacement Components: "-ASME "Repaired, Code Name of -.Manufacturers' National Other Year 'Replaced, 01' Stamped Name of Manufacturer Serial Number Board No. Identification' Built . Replacemen (Yes or No)

Componet 1988 Repaired/RepI Yes RCP Seal Sulzer Blngham 1C863 NB 1249 11B Reactor Coolant Pump 1988 Repaired/Repl Yes Mechanical Seal. aced Inc.

N/A Seal, Cartridge Assembly (RCP) -- 2001 , ReplaCement Yes Seal BGE CCNPPI,I- Shops 0199602107 SN:

1C870 - '- 875B-3V Complete Sulzer Bingham per FCR 87-0074

7. Description of Work: ,

This plan was for the replacement of the mechanical seal on #11 B Reactor Coolant Pump.`_

Pneumatic{Zl Nominal Operating Pressure Inservice: [] Leakage R Functional [

8. Tests Conducted: Hydrostatic:[:]

Pressure: 2250 psi. Test Temperature: 53. Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

9I Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section XI System Leakage Test of the affected component was performed during the system conditions listed in section 8. of this report.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliancee We certify that the statements made in this report are correct and that this RepairlReplacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: NIA Certificate of Authorization No.: N/A Expiration Date: N/A Signed:* Charles H. Ballard Signed: Engineering Technician Date: 8/15/2002 Owner or Ow~ner's De'i-grie, Tit e Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components described in this Owner's Report during the period  ?- zo - O ( to 7_-,__-o_ _ -- , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described m this Owner's Report in accordance with the requhiements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

Inspet/or's Signature National Board, Stat,* and Endorsements Date "11.12, -200Z-

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section XI

1. Owner: Calvert Cliffs Nucle-arPPower Plant, Inc. Date: --7/19/2002-1650 Calvert Cliffs Parkway; -Lusby, MD -20657 . Sheet I of -2

- (address) - ,

2. Plant: Calvert Cliffs Nuclear Power Plant unit: '--One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2001-1-054, MWO No. 1200003048 (address) I", - - (P.O. no., job no ,etc.)

Type Code Symbol Stamp: N/A

3. WorkPerformedby: Calvert Cliffs Nuclear Power Plant Dept. Authorization No.: N/A (name)

Exp Date: N/A 1650 Calvert Cliffs Parkway,- Lusby, MD 20657 " Section XI Class: One

.. . (address)

4. Identification of System: System Number 064 , System Name: , Reactor Coolant System 5.(a) Applicable Construction Code and Class: Bechtel Spec 6750-M-285A Small Stainless Steel Instrument Gate, Globe & Check Valves "1998Edition (b)i *Applicable Sect XI Ed. fýorRepairs/Replacement
6. Identification of Components Repaired or Replaced and Replacement Compoinent-s: - ASME

_Repaired, Code Name of Manufacturers National Other Year Replaced, oi Stamped Name of .

Serial Number Board No. Identification Built Replacemen (Yes or No)

Componet Manufacturer 1975 Repaired/Repl No Valve Whitey Research 1-HVRC-1180 & 1181 N/A First DralnValve ofofol-LT- No 110X, wetsideof#11 Pressurizer aced Tool Co.

N/A -Valve, Globe',3/4 in. Whitey MlK '2001 Replacement -No Whitey Globe Baltimore Valve & 400172 Valve Fitting Co. 2100, ASTM A479 Tp 316, P/N:

12NBS12GLESHW2OW22, Swagelok Comp. Ends

7. Description of Work:

This plan was for the replacement of 1-HVRC-1 180 and 1-HVRC-1 181, drain valves off of the wet side of #11 Pressurizer Instrument 1-LT-1I OX.

Pneumatic] Nominal Operating Pressure. Inservice. L] Leakage: LI Functional: L]

8. Tests Conducted: Hydrostatic'-]

N/...A psi. Test Temperature: N/.A Deg. F Pressure:

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

No Section XI Pre-Service NDE was performed in support of this activity.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Repalr/Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: NIA Expiration Date: N/A W Charles H. Ballard Signed: Engineering Technician Date: 7/19/2002 Owner or Owner's fesignmeeTile Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components described in this Owner's Report during the period 19 "-3-01 to 6 -1'*--? 2 , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind ansing from or connected with this inspection.

aNCommissions: c -a' 2aZd d ate L ad .

Inspector's Signature National Board, State, and Endorsements Date:** 200 1-

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of'the ASME Code Section XI

1. Owner: Calvert Cliffs Nuclear Power Plant, Inc. Date: 612612002 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657, - - Sheet Iof 2 (address)
2. Plant: Calvert Cliffs Nuclear Power Plant Unit: One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2001-1-056, MWO No. 1200104120 (address) (P.O. no.,job no, etc.)

Type Code Symbol Stamp: N/A

3. Work Performed by: Calvert Cliffs Nuclear Power Plant Dept. Authorization No.: N/A (name)

Exp'Date: N/A; 1650 Calvert Cliffs Parkway, -Lusby, MD 20657' -Section XI Class: Two (address)

4. Identification of System: System Numnber 052 SystemN e- Safety Injection 5.(a) Applicable Construction Code and Class: ASME B31.7 1969 Edition, Summer 1971 Add; Class Two (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition
6. Identification of Components Repaired or Replaced and Replacement Components: ASME Repaired, Code Name of Name of Manufacturers National Other Year Replaced, or Stamped Componet - Manufacturer Serial Number Board No. Identification Built Replacement (Yes or No)

Piping System Bechtel 2" GC-7-1003 N/A #I1 Containment Spray Pump 1975 Repaired/Repl No Recirc. to refueling water tank aced 404338 N/A Nut, Heavy Hex, 5/8 In. X 11 TPI, 2001 Replacement No Nut DuBose National Energy Services SA-194 Gr. 2H Inc.

Rod Cardinal Ind. 88627-GX N/A Rod, Alithread, 5/8 In. X 11 TPI, 1994 Replacement No Products SA-193 Gr. B7

7. Description of Work:

This plan was for the replacement of fastener material for 1-FO-4146, which is the mini flow for #11 Containment Spray Pump.

8. Tests Conducted: Hydrostatic E] Pneumatic*] Nominal Operating Pressure: Inservice: LI Leakage:[] Functional E]

Pressure: NIA psi. Test Temperature: N/A Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

No Section Xl Pre-Service NDE was performed in support of this activity.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Repair/Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A 7

,-Charles H. Ballard Signed: /- niern Technician Date: 6/26/2002

- Z wner or Owners Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components described in this Owner's Report during the period /0 - t j* to 6, - ,-OaZ- , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

_____ _'__gnaureNatonlardSCommissions: kat5ZZe AaZ n En09!5C7 insp~eo'sSignature National Board, State, and Endorsements Date: e:-1A LS 2002-.

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section XI

1. Owner:- Calvert Cliffs Nuclear Power Plant, Inc.* Date: 8912002 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet I of (address)
2. Plant: -.Calvert Cliffs Nuclear Power Plant .. Unit: One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2001-1-059a, MWO No. 1200001173 (address) (P.O. no ,job no , etc)
3. W*ork Performed by: Cliffs Nuclear Calvert (name) (nam) Power Plant Dept.

-Authorization Type Code SymbolNo.:

I.+

N/A* N/A Stamp:

Exp Date: N/A 1650 Calvert Cliffs Parkway. Lusbv. MD 20657 Section XI Class: Two frn44r aJ

4. Identification of System:- System Number 083 SýstemName: Main Steam &SG Blowdown 5.(a) Applicable Construction Code and Class: ASME B31.7 1969 Edition, Summer 1971 Add; Class Two (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition
6. Identification of Components Repaired or Replaced and Replacement Components: - ASME Repaired, Code
Name of Name of - Manufacturers National Other Year Replaced, oi Stamped Componet Manufacturer Serial Number Board No. Identification Built Replacemen (Yes or No)

Piping System Bechtel 1-DR-5 N/A Main Steam Piping and Drains 1975 Repaired/Repi No between liner plate and MSIV's aced

'400430 Ht. Code: "N/A Elbow, Pipe, 2 In.'90 deg. 3000 lb. 2001 Replacement No Elbow DuBose National Energy Services 75187 ASME SA-105 Inc.

99883-GX Ht. #: N/A Pipe, 2 in. Sch. 80, ASME SA-106 1995 Rellacement No Pipe Energy & Process Corporation 40007, Gr.B' 54906-GX Ht Code: N/A Coupling, 1-1/2 in., 3000 Lb., 1992 Replacement No Coupling DuBose National

  • Energy Services 026D & 073C ASME SA-105, Socket Weld Inc.

87523-GX Ht. Code: __-N/A -- Coupling Hair, 2 In, 3000 lb., -1994 ,Replacement -- No Half Coupling -- Consolidated Power Supply 088F ASME SA-105, Socket Weld 404716 Ht.#: N/A Pipe, 4 In. Sch. 40, Carbon Steel, 2001 Replacement No Pipe Tioga Pipe Supply Co. Inc. A02824 ASME SA-106 Grade B 404716 Ht#: LS4HA N/A Cap, Pipe, 4 In., Sch. 40, 2001 Replacement No Pipe Cap Tioga Pipe Supply Co. Inc. Buttweld, ASME SA-234, Gr.

NNPB

7. Description of Work:

This plan was for the replacement of 1-DR-5, which is the last drain pot that comes off upstream of #12 MSIV. The drain pot UEI is 4"EB-12-1023 and the piping to 1-MOV-6611 is 2"EB-12-1024.

8. Tests Conducted: Hydrostatic:[] PneumaticCl Nominal Operating Pressure Inservice: ED Leakage R] Functional [

Pressure: 886 psi. Test Temperature: 529 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet J.of 2-FORM NIS-2 (Back)

9. Remarks:

A Section X1 System Leakaqe Test of the affected component was performed during the system conditions listed in section 8. of this report. Code Case N-416-1 was invoked to satisfy Section XI required pressure tests. Addtional Section III Examinations were performed (as applicable) to satisfy Code Case N-416-1 and Req.Guide 1.147.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance _

We certify that the statements made in this report are correct and that this Repair/Replacement conforms to the rules of the ASME Code, Section XU.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: NIA Expiration Date: N/A Charles H..Ballard Signed: /EngJineenng

'dZ4 Technician Date: 8/9/2002 "Ownieror Owner's Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components described in this Owner's Report during the period //- 8-6>/ to 7-/7-0 Z-. , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures descnbed in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

-A44Z I iaN X&,Lge Z*arCommissions:

Ar. tizIaee I~k~ S-ignaureNational Board, State', and Endorsements D* /. 200L

FORM NIS-2 OWNER'S REPORT FOR REPAIR I REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section XI

1. Owner':- , Calver't Cliffs Nuclear Power Plant, Inc. - Date: '8/8/2002

.. .. (name) - .

1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet I of 2-(address)

Calvert Cliffs Nuclear Power Plant ... Unit: -One

2. Plant:-

-. - (name)

R&R No. 2001-1-059b, MWO No. 1200001173 1650 Calvert Cliffs Parkway; Lusby, MD 20657 (P.O no.,job no, etc.)

(address) ept. T>ype Code Syrmbol Stamp: N/A

3. Work Performed by: Calvert Cliffs Nuclear Power Plant DE Authorization No.: N/A (name) I "- i Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class: Two

-(address)_

4. Identification of System: SystemNumber -- 083 System Name: Main Steam & SG Blowdown 5.(a) Applicable Con-stiuctioinC6odeanid Class:, ASME B3317 1969 Edition, Summer 1971 Add; Class Two 1998 Edition (b) Applicable Sect XI Ed. for Repairs/Replacement
6. Identification of Components Repaired or Replaced and Replacement Components: Code Repaired,

,Other Year, Replaced, oi Stamped Name of -- Name of manufacturers National Serial Number - Board No., Identification Built Replacemen (Yes or No)

Componet Manufacturer I97, Repatred/Kepi No Piping System .Bechtel 1-DR-6 -N/A Main Steam Piping and Drains- , 1975 'Rep alredfRepi aced between liner plate and MSIV's Replacement No 400430 Ht. Code: N/A Elbow, Pipe, 2 in. 90 deg. 3000 lb. -2001 Elbow DuBose National ASME SA-105 Energy Services 75187 Inc. No 99883-GX Ht. #: N/A Pipe, 2 In. Sch. 80, ASME SA-106 1995 Replacement Pipe Energy & Process .

, '-40007 Gr.B Corporation 1992 Replacement No 54906-GX Ht Code: N/A Coupling, 1-1/2 In., 3000 Lb.,

Coupling DuBose National 026D & 073C ASME SA-105, Socket Weld Energy Services Inc.

1994 Replacement "No 87523-GX -Ht. Code: --- N/A - Coupling Half, 2 in., 3000 lb.,

Half Coupling Consolidated 088F ASME SA-105, Socket Weld Power Supply No Pipe, 4 In. Sch. 40, Carbon Steel, 2001 Replacement Tioga Pipe Supply 404716 Ht.#: N/A Pipe ASME SA-106 Grade B Co. Inc. A02824 2001 Replacement No 404716 Ht#: LS4HA N/A Cap, Pipe, 4 In., Sch. 40, Pipe Cap Tioga Pipe Supply Buttweld, ASME SA-234, Gr.

Co. Inc.

WPB

7. Description of Work:

This plan was for the replacement of 1-DR-6, which is the last drain pot that comes off upstream of #11 MSIV. The drain pot UEI is 4"EB-12-1029 and the piping to 1-MOV-6612 is 2"EB-12-1030.

8. Tests Conducted: Hydrostatic.[ PneumaticG Nominal Operating Pressure. Inservice E] Leakage. ] Functional E3 Test Temperature: 529 Deg. F Pressure: 886 psi.

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheettof 0.

FORM NIS-2 (Back)

9. Remarks:

A Section XI System Leakage Test of the affected component was performed during the system conditions listed in section 8. of this report. Code Case N-416-1 was invoked to satisfy Section XI required pressure tests. Addtional Section III Examinations were performed (as applicable) to satisfy Code Case N-416-1 and Reg.Guide 1.147.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this RepalrlReplacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: NIA Certificate ofAuthorizationNo.: N/A Expiration Date: N/A Charles H..Ballard Signed: Engineering Technician Date: 8/8/2002 Owner or Ownr's-Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components descnbed in this Owner's Report during the period //-8-o/ to 7-17-0 7... , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

-t -gnatureCommissions: EZ2Bo atoa Ar,1i Sta), A'70 Inspecdors Signature National Board, State, and Endorsemen'ts 200

ACTIVITY FORM NIS-2 OWNER'S REPORT FOR REPAIR I REPLACEMENT X1 As Required Required by the Provisions of the ASME Code Section Calvert Cliffs Nuclear Power Plant, Inc. Date: 7116/2002

1. Owner: (ae (name)  :

Sheet I of ,.

1650 Calvert Cliffs Parkway; Lusby, MD 20657 (address) -

Calvert Cliffs Nuclear Power Plant Uni t:- -One

2. Plant:

(name)

R&R No. 2001-1-060, MWO No. 1200103157 1650 Calvert Cliffs Parkway; Lusby, MD 20657 . (P.O. no., job no , etc.)

(address) *e Code Symbol Stamp: N/A Ty Power Plant Dept. horization No.: N/A

3. Work Performed by: Calvert Cliffs Nuclear Aul (name)

ExIpDate: N/A

tion XI Class: One Sec 1650 Calvert Cliffs Parkway, Lusby, MD 20657 (address) S.. . . . i SystemNumber 041 SystemName: Chemical Volume Control
4. Identificatibn of System:

One 5.(a) Applicable Construction Code and Class: ASME B31.7 1969 Edition, Summer 1971 Add; Class (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 EdiSMo and Replacement Components: Repaired, ASIME Code

6. Identification of Components Repaired or Replaced Other Replaced, oi Stamped Name of Manufacturers National Identification Built Replacemen (Yes or No)

Year Name of Board No.

Componet Manufacturer - Serial Number N/A 'Anchor separating the Main and 1975 Repaired/Repl No 2"CC-5-1003,A7 aced Pipe Support Bechtel Aux. Spray piping systems for H11 "Pressurizer Plate,-Steel 318 in. ASME SA-36 2001 Replaci'erent -No 400428 Ht. #: N/A Plate DuBose National Energy Services J1008823 "Inc. '-2001 Replacement 406428 Hft.: N/A - Plate, Steel, 3/4 In. ASME SA_-36 .

No Plate DuBose National D04009 Energy Services Inc. ' 1996 426-GX Ht. Code NIA, Nut, Heavy Hex, 1/2 In. X 13 TPI, Replacement No Nut Allied Nut & Bolt 184 SA-194Gr. 2H

- Co. Inc. - - -- 214 Replacement 14557 Ht. Code. N/A Tube Steel, Square, 4 In. X 4 In.X '1999 DuBose National 3 Tube Steel B37679 1/4 In.; ASTM A-500 Grade B Energy Services No Inc. N/A Clamp, Pipe Anchor, 2 in. for PG- 1993 Replacement 411 PG.43,perDrwg.# FSK-MP- -

Pipe Clamp Grinnell 79546-GX Ht. #

K5105 "Corporation 0571SH0003 & 0005, Part# 1.

1994 Replacement No 47477LNP N/A Clamp, Pipe Anchor Base, 2 In.

Pipe Clamp Grinnell for PG-41 / PG-43 per Drwg.#

Base Corporation . FSK-MP-0571SH0003 & 0005, Part# 5.

1994 Replacement N/A Bolt, Heavy Hex. Head, 1/2 In. X 2 No Bolt Cardinal Ind. 88627-GX In. X 13 TPI, ASME SA-1 93, Gr.

Products B7 2001 Replacement No NIA Plate, Steel, I In. ASME SA-36 Plate DuBose National 400428 Ht.# M06240 Energy Services Inc.

7. Description of Work:

is strong enough to accommodate the new design This plan was to modify anchor 2"CC-5-1003,A7 so that it

Sheet 1. of I-FORM NIS-2 (Back)

8. Tests Conducted: Hydrostatic'"] PneurnaticS] Nominal Operating Pressure: Inservice: [I Leakage: El Functional: El Pressure: N/A psi. Test Temperature: N/A Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

9. Remarks:

A Section Xl VT-3 Visual Examination of the affected component support was performed prior to the system beinq returned to service.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this RepalrlReplacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authonzation No.: N/A ExpirationDate: N/A ec?~/~~ 4 Charles H. Ballard Signed: z yz LsEnginerin Technician _Date: 7/16/2002 F

SOwner or Owner's Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components described in this Owner's Report during the period //-...--O to 4-ý -,1- ) 2, and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the AS1v2 Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

~ Commissions: 4j,3gZ_ý7 . I~E Ik/flj_

Inspeceaor'sSignature National Board, State, and Endorsements Date:9-Z,, .- 71 200 Z.-

V/

SFORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xl

1. Owner:

Calvert Cliffs Nuclear Power Plant, Inc. Date: 81912002 knam¶),

1650 Calvert Cliffs Parkway; -Lusby, MD 20657 -.-. Sheet I of 2 (address)- "

"2.Plant:' Calvert Cliffs Nuclear Power Plant Unit: One -

(name)

R&R No. 2001-1-064a, MWO No.-1200003361 1650 Calvert Cliffs Parkway; Lusby, MD 20657 (address) - .. . - ' ' (PO.no;jobno,Cetc.)

-* " 3Typ-eCode Symbol Stamp: N/A" Plant Dept.'T

3. Work Performed by: Calvert Cliffs Nuclear Power --Authorization No.: N/A

-- (name)

Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 'SectionXI Class: 'One (address)

4. Identification of System: System Number .052 SystemName: Safetylrijection -

5.(a) Applicable Construction Code and Class:- ASME B&PV Codeý Sect.'lll, 1989 Edition, Class One -

(b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition

6. Identification' of Components Repaired or Replaced and Replacement Components: .ASME

"' -" . Repaired, Code "National ' Other "Year -'Replaced, oi Stamped Name of Name of- Manufacturers "Built- Replacemen (Yes or No)

Manufacturer Serial Number Board No. 7 Iidentification Componet Repaired/Repi Yes N/A Shutdown Cooling Header First 2001 Repaired/Repl Yes

, Valve BG&E 1-HVSI-709 Isolation Drain Valve r Reedle 2001 -Riplaeement. Yes 400425 SN:001024 N/A Valve, Gate, 314 in, 1690 lb.,

Gate Valve - Framatome ANP ASME SA-182 Tp. F316, per Inc. 19 -

Drawing 12968-0132, Item 116.

7. Description of Work:

Thisplan was for the modification to install a new drain valve, 1-HVSI-7090on the Shutdown Cooling piping, 14"CC-14-1004.

8. Tests Conducted: Hydrostatic.I-- PneumaticOd Nominal Operating Pressure: lnservice" E] Leakage: E] Functional El Test Temperature: N/..A Deg. F Pressure: N/A psi.

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

and the (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

No Section Xl Pre-Service NDE was performed in support of this activity.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Repair/Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H Ballard Signed: X Engineenng Technician Date: 8/9/2002 "Owne"-'r or Owner's Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components described in this Owner's Report during the period /--/O-01 to 8 - 'Y -02__ , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

+/-Commissions: 1J86 8 Z M06- 7 Inspectors Signature National Board, State, and Endorsements Data_.¢/Z"-ý C3 200 2..

DATA PACKAGE NO. 00O1024 FORMf NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUJMPS OR VALVES*

As Required by the Provisions of the ASME Code, Section 111, Division I

- ~Pg. 1 of

1. Manufactur~ed and .certified by' VRr1 AN INC. 2125 WARD AVXZMON'~rRAL.0UEM2C CANADlA H4N2Z6 (name and address of N Certificate Holder)
2. Manufactnxred for 17RAMATO~ TZCM;OLCGIRS *3315- -O;LD -FORNST- RD.-LYNCH~tTRG.,VA.UrSA 24501
3. fLoction izisallio. - -- (name and address of purchaser).

(name and address)

4. Model No., Series No. i or_ Type: -GTý Drawing PI-76 00-X22 Rev- xH r.

_5. As2ma code, Secto -_111, 19i~o 8~-

9 - NONE W S-~~e~tfn) (addendadate) (Class) (CO&cue tso.)

6. 7ump or valve VALV9 Ncominal inlet size ... XLOutlet size M 00.
7. Malterial.>Body, SA-182,17316 DozmetSA-182F316 'Dink SA-351,CPSBM Bolting §A-l94.aM

- SA-7564,630E1100 (a) (ci (d) . I, -_) - (e)-"

cert.

  • Nat?1 -. Body - Bonat-- - Disk Holder' a- -Board Serial Serial Serial
  • Serial No. NO. No. ITO. ITO.
  • 00L024 - NJA - H/C.:A-SV x . Y7H/C: Tr 001024-2 ________ A-SV FL? _________

Q01024-3 -V________ HBX______ TT 003.024-4 __________ .. .. HE

.. TT 001-024-5 - ________A-TV F TT 001024-6 _________A-TV -M _________ TT 001024-7 ________A-TV PLY TT 001024-B - ________A-TV

-EEO =_________

001024-9 -A-TV FL

- 'TT 001024-10,

-- _______ J7AI ESE TT 001024-11 ________ 7AX HEX T 003,024-12 AI L________ HEM 003.024-13 - -JI-ZE24 TT 001024-14 ________IA EXO __________

001024-15 ________ TiFLF __________

001024-16 ________JAI REM_____ _________

001024-18__ JAI la' T7_____

001024-19 - '-.JZ PYT

_001(124-20 - ________? ~ __ _________

Supp~eteata1 infoxv~don Info= qf sWsketches, or drawings may be used provided (1) siz4 L7 lIx 11, (2) information Enitems 1 through 4 on thIs Data Report is~ aiued 'n each heet,(3) e -itIsnumbered and the number of sheets is recorded at the top of this form. **

(12/88) Thts form (ED0037) inai' be obtained from the Order DepL, ASNIE, 22 LAW DRZVE< BOX 2300 FAirfieldNJ 07007.2300.

A UP 5UP

- \y~..GEA

FORM NPV-1 (Back - Pg. 2 of 2 )

Certificate -Holder' s Serial No. 001024 S. Design conditions 4055 psi 100 OF or valve pressure class 1690 (1)

(pressur)e (te=peratuxe)

9. Cold working pressure 4055 psi at 100"F
10. Hydrostatic test 6350 psi. Disk differential test pressure __4650 psi
11. Re=arks: MAT3RIALS M3M ASMM SECTIO -I RDITI0N- 1989 ADDENDA- NONM CERTIPICATS OF DESIGN Design Specification certified by .TLav' ne P.X. State _7 Reg.

Design report certified by no.

S. ITSBTSXY P.Z. State Reg. \no.

.Q _22315 CERTIXICATE OF COMPLZANCE We certify that the statements made in this report valve conforms to the rules for construction of are correct and that this pump or the ASMH Code,. Section lIZ, Division 1.

N Certificate of Authorization No. IT-2797-1 V 2,2001 Date SEP 26 20 Name y " =C. siigned (N CertlEicte Holder) (uh CERT7ZCAZH OF INSPECTIONT 1, the undersigned, holding a valid commissibn issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of OB'MRC '_ and employed by MllI D]J 3ATflK1q ofg in t*is have inspected the and state that to the best or valve, desc=ibed.'

Data Report on pump, belief, the Cert*ficate Hol er has consnrucEed this of my knowledges id pump, or valve, in-accordance with--Mi ASX3 Code,. Section XIl, .Di'ision 1.

By signing thi.* certificati, neiter the *inspector nor his employer makes any warrenty, expressed or implied, concerning the component described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable or propert in any manner for any personal injury ge or a loss f any kind arising from or connected with this inspection.

Datep o signee d Comissions _tMB=

J.MARCHAND QC8T4 torized Inspector) (N21'L Bd. CmLUMt AJ"TmDu OutBEC sute or pray. and no.1 (1) ?r manually operated valves only.M

'oiL732S3AGE ==9

° FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Requiredi by the Prrovisions of th'eA'SMiE Code Section XI Date: 8/912002

1. Owner: Calvert Cliffs Nuclear Power Plant, Inc.

(name) 1650 Calvert Cliffs Parkway; Lusby, MD,20657 ......... Sheet I of.2.

(address). - ,

2. Plant:" :---..Calvert Cliffs Nuclear_Power Plant. . - Unt: . One .. , - _.-

(name) .

" -1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&RNo. 2001-1-064b, MWO-No. 1200003361-

- .' '" :4"

- (address) , - .. - (P.O no,jobno,etc) -- " .. -

Calvert Cliffs Nuclear Power Plant Dept. Type-Code Symbol Stamp: N/A

3. Work Performed by: - Authorization No..-NiA

-(name) - * . PDe Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657' Section XI Class: --One (address)

4. Identification of System: System Number _052 System Name:, Safety Injection
5. (a) ,Applicable Construction Code and Class: -ASME B&PV Code Sect. Ill, 1989 Edition', Class One (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition
6. Identification of Components Repaired or Replaced and Replacement Components: -ASME

- - " Repaired, 'Code Name of Name of Manufacturers National Other . Year, Replaced, o Stamped Componet Manufacturer

  • Serial Number.- Board No. Identification -_ Built Replacemen (Yes or No)

N/A Shutdown Cooling Header Second 2001 Repaired/Repl " Yes 1 Valve BG & E 1-HVSI-710 Isolation Drain Valve aced NIA Valve, Gate, 314 in, 1690 lb., 2001 Replacement Yes Gate Valve -Framatome ANP 400425 SN: 001024- * -

Inc. 20 ASME SA-182 Tp. F316, per Drawing 12968-0132, item 116.

7. Description of Work:

piping, This'plan was for the modification to install a new drain valve- 1-HVSl-710, on the Shutdown Cooling 14"CC-14-1004.

Pneumaticd Nominal Operating Pressure: Inservice [] Leakage: [] Functional'[]

8. Tests Conducted: Hydrostatic []

Pressure: N/_A psi. Test Temperature: NI/A Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

is numbered and the (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet number of sheets is recorded at the top of this form.

_________ L____ -______

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

No Section XI Pre-Service NDE was performed in support of this activity.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Repalr/Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No: N/A Expiration Date" N/A P// Charles H Ballard Signed. _ ' Engineering Technician Date: 8/9/2002 Ow~ner orOwmner's [ ine.-Ti Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components described in this Owner's Report during the period / Z-/d-d/ to 6-7-6-7-. , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

/nd NaonloadSa,,Commissions:Endrsement Inspect s Signature National Board, State, frid Endorsements at - 200 el

DATA PACKAGE NO. 0010O24 FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES*

As Required by the Provisions of the ASME Code, Section 111, Division 1

  • .Pg~of -2
1. Xanufactu~red and certified by -VLAfýZ,-22 WflAHMONTREAL. OUEBSCCANADA 1H4X1%6_

(name and addrms of NZCertificatte Holder) . - ~ :- *~

-- 2.- Manufac tured for PR MTOMETECE1OLOGZB.ý *3315-A ODD FORE T RD. LY ýUIG. VA.MA7 24 501

3. ~- istallien- - - -(namie and address ofpurcbaser) - . .

(name and address)

4. MXodel No.1, Series Noz' -or-Type:'Gz -D;Zia -P76aba-N22 3tev- ___N pj
5. 2SXH Code,--Section~Z II; Div~ision 1.: JIML~----NN

- - -~~ -. (edition) - ~~... (added date) _____

- ( s) - (Cd Cae o.

6. Pump or vatlve VALVZ NmiL~ail, izilet size ...XLOutlet size X....~L....

-7. Hat:erial:tBodyl, SA-1 2,F316 BonnetSA-182,F316 Diskc SA-251,CPSM - BoltIng 6L-194.8M SA-5 64, 630E1100 Cert.> H at-1 -. Body! Bonnet Ds


Holderla 'Board Serial Serial serial

  • Seirial No. NO. N.- O. o W/C: FLY H/C: TT

-.- 001024-2 A-,SV 001024-3 rEM A-S 601024-4 B-MB HEM 001-024-5 A-TV TT 001024-6 A-TV HEBX TT A-TV TT 001024-7 TT 0010 24-8 A-TV 001024-90 001024-10 J7AI EBM

'ATI 001024-11 33MX 001024-12 JAI TI' 001024-31S4 HEM1 00 024-14 JAI

'ml TI' 001024-15 FLF

¶ 001021-16 * 'm MEN OAT EMN Trr 001024-17 TI'

- JAI

  • 061024-20 tu=== =n Supplepenala hinorzndon in foam 9f Yits, sketches, or drawings may be used provided (1)siz*44 ý U/2x 21, (2) Information InItems 1-through4 ou Wii Data *eort.

is iud'ue~t~nech iheeQ.3) eiath-i'bett Is numbered and the number of'shietts is recorded at the top of thls form.

(12/88) 'Tlds form (ED00037) =2y be obtained from the Order Dept., ASMI, 22 LAW DRIVE< BOX 2300 FafrfieldTrU 07007-2300. TI

I FORM NPV-1 (Back - Pg. 2 of 2 )

Certificate'Holder.s Serial No. O9L1_24

8. Design conditions 4055 psi I00 *P or valve pressure class_1690 (1)

(pressturo (temperatue)

9. Cold working pressure 4055 psi at 1000F
10. Hydrostatic test 6350 psi. Disk differential test pressure 4650 psi
11. Remarks: MATEXRXALS M .*M SECTION I EDITZO- 1989 ADDENDA. NONE CERTI-ICAT3 OF DESIGN Desig Specification

~

Deslg* etie ~ certified

~ ~ ML.L, by S aeSX*SY rpr P.-.

P.N. State -- UE_ Reg.

.* Reg- \no.

no: _21 40052 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report valve conforms to the rules for construction are correct and that this pmp or of the ASME Code,.Section III, Division 1.

H Certificate of Authorization No.

M-2797-1 RY 2200l Data' SEP 26 MOMO Name V". C.

=C, Sig=ed (N Cerdtkate Holder) (Sutbl*t CXRTF'*CATZ OF XNSPRCTION I, the undersigned, holding'a va-lid co=minsibn Pressure Vessel Inspectors and the State or Province issued by the National Board of Boiler and "MiE D3ATWMot MI of 2 QUEBEC and employed by of - ha-e inspected the p.....

in thi. Data Report on or v7alve, described.

  • d an state that to the best of my knowledge aznd belief, t~he Certificate Nolmer bas ccnstrucEfd this pump, or valve, in-accordance withL-Ue ASNI Code, Section III, Division 1.

By signing thi.i certificati, .neiter the 'inspector nor bis employer makes any warrenty, expressed or implied, concerning the component described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or propert damage or a loss I any kind arising Date4 Dt I 'LZ from or connected with this inspection.

J.MARCHAND QC #87* 4 signed. Cormissions OUEBEC thorized Inspertor) (Nat'L Bd. CaocLAV~i2T0U QUtBEC state or pra. amd no.)

(1) For manually operated valves only.

. P.PAGE

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of th6 ASME Code Section XI

1. Owner: Calvert Cliffs Nuclear.Power Plant,- Inc. ,Date: ' 7119/2002 -

(name) 1650 Calvert Cliffs Parkway; Lusby, MD -20657 Sheet of :.

2- - -t: .. a.. e_. Cliff Nuclear.P.,

ess er Plant- - 1-addr ni One 2."ln:-Calvert ant.~Cliffs -Uni .Nuclear.P~oWer Plant-..... ,- -- OUeit: e -. -- . -.

-. .... (name) .

,R&R No. 2001-1-064c, MWO No. 1200003361 1650 Calvert Cliffs Parkway; Lusby,- MD 20657

-. (addreis) . -z7.: .....-. . - (P.O no ,job no;etc.) . "

3." Work Performedb Calvert .Cliffs Nuclear Pdwer Plat Dept. p Code..Sybol Stamp: N/A --

Tye

. Wk P e b- 'Authorization No.: -N/A

.-Exp Date: N/A, 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class: One.

(address)

4. Identification of System: System Number -064 SystemName:- Reactor Coolant System 5.(a) Applicable Construction Codeand Class: ASME B31:7 1969 Edition6, Summer*1971'Add; Class One 1998 Edition (b) Applicable Sect XI Ed. for Repairs/Replacement
6. Identification of Compofients Repaired or Replaced and Replacement Components: - ASME Repaired, Code Year Replaced, oi - Stamped Name of Name of -..---- Manufacturers --National . ... Other -..

Board No. ' Identification Built Replacemen (Yes or No)

Componet Manufacturer Serial Number 1975 Repalred/Repi No CC14-1004 N/A Shutdown Cooling Piping 1975 Repalired/Repi No Piping System Bechtel "ThroughContainment to Isolation -" aced -

Valves Pipe Tioga Pipe Supply 404796 Ht.#A30014" ",N/A Pipe, 3/4 In. Sch 80, ASME SA- 2001 Replacement No Co. Inc. S..... 376,TP-316.

Replacement No Nut, Heavy Hex, 3/8 in. X 16 TPI, ,1998 23106 Trace Code: N/A Nut Allied Group S -- , ASME SA-194 Gr. 2H1

. " Q58 1991 Replacement No Tioga Pipe Supply % 20441-GX Heat SN/A'

Half Coupling "ASMESA-182,Tp. F316, Socket

-Co. Inc.Z Code: EEH

85611-GX Heat N/A Clamp, Anchor, 314 in. Part# 1 of 1993 Replacement Anchor Clamp Grinnell Corporation Code: PL084 PG-41142/43 on Drwg.# FSK-MP 0571SH0003, 0005 & 0006 No 54500-GX Heit N/A--  ! Clamp, Restraint Base, 3/4,in. - 1991 Replacement

,Base, Clamp 'Grinnell

- C orporatio n_ Code: PL-097 Part# 5 of PG-41/43 on Drwg.#

FSK-MP-0571SH 0005 Bolt Allied Group 41695 Ht. #: 63888 N/A Bolt, Hex. Head, 3/8 in. X 1 114 In.,- 2001 - Replacement No

- . X 16 TPI, ASME SA-193, Gr. B7 . .

N/A Tube, Steel, 2 In. X 2 In. X 1/4 In., 2001 Replacement No Tube Steel DuBose National 400428 Hr.#:

ASTM A-500 Gr. B Energy Services 843D68110 Inc.

404967 N/A Clamp, Pipe, 14 in., Medium, 2001 Replacement No Pipe Clamp Anvil International Grinnell Fig. 212N, with Bolting Inc.

N/A Tube, Steel, 3 In. X 3 in. X 1/4 in., 2001 Replacement No Tube Steel DuBose National 400428 HtJ# GF0413 ASTM A-500 Gr. B Energy Services Inc.

7. Description of Work:

This plan was for the new piping, fittings and hanger support material to be used on the modification to install a new set of drain valves, 1-HVSI-709 and 710, on the Shutdown Cooling piping, 14"CC-14-1004.

Sheet X-of X*

FORM NIS-2 (Back)

8. Tests Conducted: Hydrostatic El PneumaticC] Nominal Operating Pressure: Inservice" E3 Leakage, [I Functional Ej Pressure: N/A psi. Test Temperature: NLA Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

9. Remarks:

No Section X! Pre-Service NDE was performed in support of this activity.

Applicable Manufacturer's Data Reports to be Attached We certify that the statements made inCertificate of Compliance this report are correct and that thisS Repair/Rep

_Rp__________

acement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A Signed:

Charles H.Ballard gneenng Technician Date: 7/19/2002 Owner or Owner's Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components descnbed in this Owner's Report during the period /Z-16.-'O( to 8-C--OZ. ,.and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

L Commissions: AJ* o & 2e AAJj *w--l.

Inspector's Signature National Board, State, and Endorsements Date 2007._

6'

FORM NIS-2 OWNER'S REPORT FOR REPAIR I REPLACEMENT ACTIVITY As Required Required by the Provisions of the AS M-E Code Section Xl

1. Owner:

Calvert Cliffs Nuclear Power Plant, Inc. "Date: 711512002 Sheet I of 2 1650 Calvert Cliffs Parkway; Lusby, MD .20657 --

(address)

( - 1 Calvert Cliffs Nuclear Power Plant Unit: I One

2. Plant:

(name)

R&R No. 2001-1-069, MWO No. 1200'100808 1650 Calvert Cliffs Parkway; Lusby, MD 20657

_. *. ; * - - - .- (P.O no ,job no , etc.)

(address)

3. Work Performed by: Calvert Cliffs Nuclear Powerr Plant Dept. Type Code Symbol Stamp: N/A Authorization No.: N/A (name)

Exp Date:. N/A Section XI Class: Two 1650 Calvert Cliffs Parkway, Lusby, MD 20657 (address)

4. Identification of System: System Number 083 SystemName: . Main Steam & SG Blowdown  !

5.(a) Applicable Construction Code and Class: ASME B16.5, 1968 Editini, Steel Pipe Flanges and Flanged F'inihgs NPS 1/2" thru 24" & CCase N-10 . ,

1998 Edition -

(b) Applicable Sect XI Ed. for Repairs/Replacement

6. Identification of Components Repaired or Replaced and Replacement Components: ASME

. Repaired, Code Stamped National Other Year -Replaced, or Narme of Comnonet Name of*' Manufacturers Serial Number Board No. Identification Built Replacement .(Yes or No)

Manufacturer C. ... ,i t

Valve Copes Vulcan Inc. 7010-95030-1-1 N/A #11 Main Steam Header I 75b Repairewm~epi Atmospheric Dump Valve aced  ?-

No 402259 SN:01-1 N/A Trim, Plug Ass., Valve, 5 Inch, 2002 -. Replacement Plug Assembly Copes-Vulcar Inc.

6001b., press. retaining parts; Plug, #145380, Inner Plug #145381

7. Description of Work: ... ',..

This plan was for rebuilding 1-CV-3938, Atmospheric dump Valve.

8. Tests Conducted: Hydrostatic fl Pneumatici] Nominal Operating Pressure: Inservice: L] Leakage. E] Functional: LI Test Temperature: N/..A Deg. F Pressure: N/A psi.

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

the (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

No Section X1 Pre-Service NDE was performed in Support of this activity.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Reparr/Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H. Ballard Signed: Engineering Techncian Date: 7/15/2002 Owner or OCwner's fesignee, title '

Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components described in this Owner's Report during the period Z--oZ.._. to 6-' -/69 -0Z_- , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described m this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

,// /3'z - C-

- omniissions: 112,g-, Z_ , A l/, n,2 7 "Inspector'sSignature National Board, State, andEndorsements D* 200

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Prdisi-ons of thle ASME Code Section XI

.._ Oer: .. Calvert Cliffs Nuclear Power Plant, Inc. bate: 7/1212002.

1n. mOnr e 1650 Calvert Cliffs Parkway; Lusby, MD 20657.- - -.- Sheet'1 of 2'

_ (address)

2. Plant: Calvert Cliffs Nuclear Power Plant Unit: --One, (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2001-1-070, MWO No. 1200100809 (address) -, - -(P.O. no,job no, etc.)

Type Code Symbol.Stamp: N/A

3. Work Performed by: Calvert Cliffs Nuclear Power Plant Dept. Authorization No.: N/A (name) "Thrn Dante: NIA "'

1650 Calvert Cliffs Parkway, Lusby,'MD 20657 Section XI Class: Two (address)

_4. Identification of System: SystemNumber 083 - systemName: K Main-ste-i-&SG BloidownV

5. (a) Applicable Construction Code and Class: ASME B16.5,'1968 Edition, Steel Pipe Flanges and Flanged

" -- Fittings NPS 112" thru 24" & CCase N -

(b) Applicable Sect XI Ed.-for Repairs/Replacement . . 1998 Edition

6. Identification of Components Repaired or Replaced and Replacement Components: ASME Repaired, Code Year Replaced, or Stamped Name of Name of : : Manufacturers .National Other (Yes or No)

Serial Number Board No. Identification Built Replacement Componet Manufacturer Valve Copes Vulcan Inc. 7010-95030-1-2 N/A #12 Main Steam Header I 975 Repaired/Repl No Atmospheric Dump Valve aced N/A Trim, Plug Ass., Valve, 5 Inch, 2002 Replacement No Plug Assembly Copes-Vulcan Inc. - 402259- SN: 01-2 6001b., press. retaining parts; Plug, #145380, Inner Plug #145381

7. Description of Work: .

This plan was for the rebuilding of 1-CV-3939, Atmospheric dump Valve.

8. Tests Conducted: Hydrostatlc:r-I Pneumatic] Nominal Operating Pressure: Inservice- [] Leakage. E Functional E]

Pressure: N/.A psi. Test Temperature: N!/A Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

No Section X! Pre-Service NDE was performed in support of this activity.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in tius report are correct and that this Reopair/Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H. Ballard Signed: Engineenng Technician Date: 7/12/2002 Owner or Owner's Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components described in this Owner's Report during the period Z-- )

O to ',-/,9-C'Z._ , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

Commissions: NIation BoarJ AIte and E em

ý/sopc esX~gau'reNational Board, State,'and Endorsements Dat . -200 Z...

6/

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section XI

1. Owner: Calvert Cliffs Nuclear Power Plant, Inc. Date: 7/18/2002 (name) 1650 Calvert Cliffs Parkway; Lusby, MD ,20657 Sheet I of 2"

. (address) .. .

2. Plant: Calvert Cliffs Nuclear Power Plant "Unit: One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2001-1-072, MWO No. 1200103303 (address) .(PO.no,jobno,etc)

ýType Code Symbol Stamp: N/A

3. WorkPerformedby: Calvert Cliffs Nuclear Power Plant Dept. Authorization No.: N/A (name)

Exp Date: N/A 1650 Calvert Cliffs Parkway, Lu-sby, MD 20657- Section XI Class: Two

- (address)

4. Identification of System: - SystemNumber 045 System Name: .. Feedwater 5.(a) Applicable Construction Code and Class: ASME B31.1.0 1967 Edition, 1972 Add 1998 Edition' (b) Applicable Sect XI Ed. for Repairs/Replacement
6. Identification of Components Repaired or Replaced and Replacement Components: ASME Repaired, Code Manufactureis National Oth er Built Replaced, 01 Year Stamped Name of Name of Replacemen (Yes or No)!

Componet Manufacturer Serial Number' Board No. Identifi,cation Valve Rockwell SN: E5711-28 NIA #12 Steam Generator Feedwater 1975 Repalred/Repl No International Supply Check Valve aced N/A Screw, Hvy Hex Hd,16 in. Check 2000 Replacement No Screw Edward Valves Inc. 400813 Heat Code:

1031 Valve, Edwards Fig. 970Y, A-193 CGr. B7,Drwg.12399-0002/0022 Item #12 N/A Retainer, Hinge Pin,16 In. Check 1997 Replacement No {

Retainer Edward Valves Inc. 12001 SN: 26970-3 l Valve, Edwards Fig. 970Y, SA

.. .182, Gr. FI1, Drwg.12399-0022 .

Item #13 Cover, Pressure Seal, 16 In. Check 2002 Replacement No Cover Edward Vogt Valve 405740 Heat Code: NIA Co. 72355 Valve, A-216, Gr .WCB or SA 182, Gr. FIl, Drvg.12399-0022 Item #3

7. Description of Work:

This plan was for the work that was performed to 1-CKVFW-130, #12 Steam Generator Feedwater Check Valve.

8. Tests Conducted: Hydrostatic:[] PneumaticO] Nominal Operating Pressure. Inservice [I Leakage" ] Functional E]

Pressure: N/.A psi. Test Temperature: N/.A Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section XI System Leakage Test of the affected component was performed during the system conditions listed in section 8. of this report.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this RePair/Rep lacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H. Ballard Signed: Technician Date: 7/18/2002 0we's U esi e, -Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components described in this Owner's Report during the period Z--' Q Z... to 6-z/--/ . , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described m this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

-" ) -~2.'to Sn Cmmsio*Nationa oar Satoai n ptor's signature National Board, State, and Endorsements Date AJI ý,Td200 Z k¢l V

"FORM NIS-2 OWNER'S REPORT FOR REPAIR I REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section XI Calvert Cliffs Nuclear Power Plant, Inc. Date: 7/1812002

1. Owner:

(name)

Sheet 1 of 2 1650 Calvert Cliffs Parkway; Lusby, MD 20657' S .. . . . . . . (address) ...

Calvert Cliffs Nuclear Power Plant Unit: - One

2. Plant:

(name)

R&R No. 2001-1-075, MWO No. 1200101396 1650 Calvert Cliffs Parkway; Lusby, MD 20657 (address) (P.O no, job no, etc.) -

Calvert Cliffs Nuclear Power Plant Dept.' Type Code Symbol Stamp: N/A

3. WorkPerformedby: Authorization No.: N/A (name) Exp Date: N/A "SectionXI Class: O0le 1650 Calvert Cliffs Parkway, Lusby, MD 20657, S(address)

System Number 064 System Name: Reactor Coolant System

4. Identification of System:

5.(a) Applicable Construction Code and Class:, ASME B&PV Code Sect. i11,1968 Edition, Winter 1968 Add; Class A, CCases N-2, N-10 .

(b)'Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition

6. Identification of Components Repaired or Replaced and Replacement Components: ASME Repaired,' Code Year Replaced, oi Stamped Name of Manufacturers National Other Name of 'Identification Built Replacemen (Yes or No)

Componet Manufacturer - Serial Number "Board No.

,1977 Repalred/Repl - Yes Valve Dresser Industrial SN: BM-07953 N/A Unit One Pressurizer Safety aced Valve Co. Relief Valve Relief Valve Dresser Industries 400078 SN:BN NIA Valve, Consolidated Closed S2001 Replacement-"'.. Yes 04373 Bonnet Maxlflow Safety; 2-1/2 in.

- Inc.

Model 31739A, only for RV 200 location.

7. Description of Work: .. . .... . .. . .

This plan was for the replacement of Unit-1 Pressurizer Safety Valve, 1-RV-200.

Hydrostatic [- Pneumatic"] Nominal Operating Pressure. Inservice: ] Leakage* R Functional [1

8. Tests Conducted:

Test Temperature: 53. Deg. F Pressure: 2250 psi.

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

the (2) information in Items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section Xl System Leakaqe Test of the affected component was performed durinq the system conditions listed in section 8. of this report.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this RepalrlReplacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A S/75 Charles H. Ballard Signed: g Technician Date: 7/18/2002 Ovwner r**rwneurs es'inee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid conmmission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components described in this Owner's Report during the period Z,.-6 to

. 7-1(  ?-O. , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examnations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

/ýýksi naturmmissions- 4jý Z 1A11D126 56i Intpe ' National Board, State, and Endorsements Date: 200Z _

FORM NVR-1 REPORT OF REPAIR [ MODIFICATION D- OR REPLACEMENT Z OF NUCLEAR PRESSURE RELIEF DEVICES

1. Work performed by Dresser Valve Divisioh; Dresser Equipment Group, Inc. 400078 01-27420-0

( name of organizaton ) (P.O. no., job no., etc)

Intersection Hwy. 167 @ 3225 North, Alexandria, Louisiana 71309

( address )

2. Work performed for Baltimore Gas & Electric Co. 1650 Calvert Cliffs Parkway Lusby, Maryland 20657 (name and address)
3. Owner Baltimore Gas & Electric Co. 1650 Calvert Cliffs Parkway Lusby, Maryland 20657 (name)

(address)

(Baddress Baltimore ) Gas & Electric Co. Calvert Cliffs Nuclear Station

4. Name, address and identification of nuclear power plant 1650 Calvert Cliffs Parkway Lusby, Maryland 20657
5. a: Repaired pressure relief device: Safety Valve b: Name of manufacturer Same as item 1 above c: Identifying'nos. 31739A BN-04373 N/A STEAM 2-1/2" 1977

( type) ( mf's senal no.) (Natl. Bd. No.) ( service ) (size) (yearbuilt) d: Construction Code ASME Section I11 1971 Summer 1972 NIA 1 (namelsection/divwslon ) (edition) (addenda) (Code case(s)) (Code Class)

6. ASME Code Section XI applicable for in service inspection: 1983 SLimmer 1983 N/A (code Case(s) )

(addenda)

(edition) N/A Summer 19133

7. ASME Code Section XI used for repairs, modifications, or replacements: 1983 (addenda) (Code Case(s))

(edition)

Summer 1972 N/A

8. Construction Code used for repairs, modifications, or replacements: 1971 (addenda) (Code Case(s))

( edition)

9. Design responsibility Same as item 1 above
10. Opening pressure: 2485 PSIG Blowdown (if applicable) N/A  %. Set pressure and blowdown adjustment made at: Wyle Laboratories, Huntsville, Alabama Using Steam

"(location) (test medium)

11. Description of work: (include name and identifying number of replacement parts) Valve Was Disassembled, Nozzle Torqued, Seat Lapped, Assembled, & Tested. Parts Replaced: Guide/Support Plate Gaskets PIN 3831018N, Cotter Pins PIN 2220219, &

Adj. Ring Pin Gaskets PIN 3610508.

12. Remarks:

CERTIFICATE OF INSPECTION I, /erY"'/ VI,, - , certify that to the best of my knowledge and belief the statements made In this report are Correct and'the repair, modification or replacement of the pressure relief devices described above conforms to Section XI of the ASME Code and the National Board Inspection Code "VR" and "NR" rules.

VR-70,95,97-118 & 120-124 to use the "VR" stamp expires 6-29-2001 National Board Certificate of Authorization No.

6-30-2002 National Board Certificate of Authorization No. NR-45 to use the "NR' stamp expires Quality Engineer Date 1/- ,- 00 Same as Item 1 above. Signed

  • 4 __-'.

(name of certificate holder) 1poo -representative) (Uile)

CERTIFICATE OF INSPECTION

!*, 5/'* * ,,*. , holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors and certificate of competency issued by the jurisdiction of Louisiana and employed by Hartford Steam Boiler Inspection and Insurance Co. of Hartford, CT have inspected the repair, modification or replacement described In this report on 4,6 and state that to the best of my knowledge and belief, this repair, modification or replacement has been completed in ac ordance with Section XI of the ASME Code and the National Board Inspection Code "VR" and "NR" rules.

By signing this certificate, neither the undersigned nor my employer makes any warranty, expressed or implied, concerning the repair modification or replacement described in this report. Furthermore, neither the undersigned nor my employer shall be liable in any manner for any personal injury, property damagrlsso k ing from or connected with this inspection.

Date Signed " C s Naional Board (Cinc. eden-Jurisdiction, and no.)

"-FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASýME Code Section XI Calvert Cliffs Nuclear Power Plant,']nc. Date: - 711812002.

1. Owner:

(name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 -Sheet Iof 2  :

... ... ... . (address) -

Calvert Cliffs Nuclear Power Plant Unit: One

2. Plant:

(name)

R&R No. 2001-1-076, MWO No. 1200101398 1650 Calvert Cliffs Parkway; Lusby, MD 20657 (address) (P.O no.,job no., etc.)

Tp CodeSyblSapN/

Symbol Stamp: N/A

3. Work Performed by. Calvert Cliffs Nuclear Power Plant Dept.

Perfre bAuthorization No.: N/A (name)

Exp Date: N/A 1650 CalvertCliffs Parkway, Lusby, MD 20657 SectionXI Class: One (address)

4. Identification of System: -.System Number 064 System Name: Reactor Coolant System 5.(a) Applicable Construction Code and Class: ASME B&PV Code Sect. Il, 1968 Edition, Winter 1968 Add; Class A, CCases N-2, N-10 (b) Applicable Sect XI Ed. for Repairs/Replacement -. 1998 Edition 1998 Edition
6. Identification of Components Repaired or Replaced and Replacement Components: - ASME "Repaired, Code National" Other Year Replaced, oi Stamped Name of' Name of Manufacturers Built Replacemen (Yes or No)

Manufacturer Serial Number Board No. Identification Componet 77 Repaired/RepI Yes Valve Dresser Industrial SN: BM-07948 N/A Unit One Pressurizer Safety 19 77, RepairedfRepl Yes aced Relief Valve Valve Co.

"2000 Replacement Yes Dresser Industries 400743 SN: BM N/A Valve, Consolidated Closed

'Relief Valve I Inc. S07952 Bonnet Maxiflow Safety; 2-1/2 In.

Model 31739A, only for RV 201 location.

7. Description of Work: . . . .

This plan was for the replacement of Unit-1 Pressurizer Safety Valve, 1-RV-201.

8. Tests Conducted: Hydrostatic.[-] PneumaticSi Nominal Operating Pressure Inservice: El Leakage.l-] Functional: []

Test Temperature: 5 3_0 Deg. F Pressure: 2250 psi.

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 -

FORM NIS-2 (Back)

9. Remarks:

A Section Xl System Leakage Test of the affected component was performed during the system conditions listed in section 8. of this report.

Applicable Manufacturer's Data Reports to be Attached Certificate of Com pliance Repar/R plac men We certify that the statements made in this report are correct and that this RearRelacement forms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate ofAuthonzationNo.: N/A Expiration Date: N/A

/ Charles H. Ballard Signed: Engineering Technician Date: 7/18/2002 Owner or Owner's Ddsignee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components described in this Owner's Report during the period /-5 8-0 _.. to //- 0 2.- , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

- " nns sg r "Commossions: B2 rS A znJ dA10m 6n Crnp/o's` S ign ature National Board, State, and-Endorsements Date: Q4 ,30 E200.,

OR REPLACEMENT Z s--- FORM IMVL*- RFPORT OF REPAIR {

f MODIFICATION NJUCLEAR PRESSURE RELIEF DEVICE El 400743 U1-t3-1

1. Work performed by Dresser Valve Division; Dresser Equipment Group, Inc. 400743 01-27388-1 (P.O. no, job no.*etc)

( name of organization)

I,4,-m Wv 1R7 ny 3225 North. Alexandria. Louisiana 71309 (address )

2. Work performed for Baltimore Gas & Electric Co. 1650 Calvert Cliffs Parkway Lusby, Maryland 20657

( name and address )

3. Owner Baltimore Gas & Electric Co. 1650 Calvert Cliffs Parkway Lusby, Maryland 20657 (name)

(address )

4. Name, address and identification of nuclear power plant Baltimore Gas & Electric Co. Calvert Cliffs Nuclear Station 1650 Calvert Cliffs Parkway Lusby, Maryland 20657
5. a: Repaired pressure relief device: Safety Valve b: Name of manufacturer Same as item 1 above 31739A BM-07952. NIA STEAM 2-1/2" 1977 c: Identifying nos. (saze) (year buitt)

( typem) (m senal no ) ( Natl Bd. No ) ( service )

ASME Section II! 1971 Summer 1972 NIA 1 d: Construction Code (Code Class)

(namelsection/dMvislon) (edition) (addenda) (Code case(s))

1983 Summer 1983 N/A

6. ASME Code Section XI applicable for in service inspection: (addenda )

(Code Case(s))

(edition) N/A 1983 Summer 1983

7. ASME Code Section XI used for repairs, modifications, or replacements: (edition) ( addenda )

(Code Case(s))

N/A 1971 Summer 1972

8. Construction Code used for repairs, modifications, or replacements: (edition) (addenda)

(Code Case(s))

9. Design responsibility Same as item I above Blowdown (if applicable) N/A  %. Set pressure and blowdown adjustment
10. Opening pressure: 2550 PSIG Using Steam m d iocaon ) (test medium)
11. Description of work: (include name and identifying number of replacement parts) Valve Was Disassembled, Nozzle Torqued, 2220219, &

Seat Lapped, Assembled, &Tested. Parts Replaced : Guide/Support Plate Gaskets PIN 3831018N, Cotter Pins P/N Adj Ring Pin Gaskets P/N 3610508.

12. Remarks:

CERTIFICATE OF INSPECTION 1, rv-V 1/. ,-_ , certify that to the best of my knowledge and belief the statements made in this report are Xl of the ASME Correct andi{he repair, modification or replacement of the pressure relief devices described above conforms to Section Code and the National Board Inspection Code "VR" and "NR" rules.

VR-70,95,97-118 & 120-124 to use the "VR" stamp expires 6-29-2001 National Board Certificate of Authorization No.

NR-45 to use the 'NR" stamp expires 6-30-2002 National Board Certificate of Authorization No.

Quality Engineer Same as Item 1 above. Signed_*

  • z/..

.k) (title)

Date //_ to . go (name of certificate holder ) iAuthorped representative J e holder)

  • /*,, , / CERTIFICATE OF INSPECTION I, holding a valid commission issued by The National Board of Boiler and Pressure Vessel Louisiana and employed by Inspectbrs and certificate of competency issued by the jurisdiction of of Hartford, CT have inspected the repair, modification or replacement Hrtford Steam Boiler Inspection ane Insurance Co.

AT and state that to the best of my knowledge and belief, this repair, modification or descnbed in this report on . 4a6 and the National Board Inspection Code "VR" and replacement has been compl&te in- accordance with Section Xl of the ASME Code "NR" rules.

the repair By signing this certificate, neither the undersigned nor my employer makes any warranty, expressed or implied, concerning shall be liable in any modification or replacement described in this report. Furthermore, neither the undersigned nor my employer or Ioss ny kin0rising from or connected with this inspection.

manner for an personal injury, property dama Date J4L Signed 4 ~ L~ Commissions_

(National Board (ncl endorsements), aYd Iunsdiction, and no)

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section XI 1 Owrer: Calvert Cliffs Nuclear Powv Praitl'Inc.Date: /1812-02 (name) .

1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet 1of 2

.............. (address)

SCalvert Cliffs Nuclear Power Plant'--, " . "'Unit: 0 One ....

2. Plant: _ -,

(name)' -

R&R No. 2001-1-077,-MWO No. 1200101781 1650 Calvert Cliffs Parkway;' Lusby, MD 20657 (P.O. no ,job no., etc)

(address)

Type Code Symbol Stamp: N/A

3. Work Performedby: Calvert Cliffs Nuclear Power Plant Authorizaiion No.: N/A (name) Exp Date: N/A Qýpt;nn Y T Class: nn a

~j~m~z~ ~I k "ri ')flr.7 1iooU CalVerL tIlllb roll hWczy, wyi- LULaii, us. ,

(address) - ,

4. Identifictilon of Sytem: SystemNumber 064 'S"ystemName: _,Reactor Coolant System
5. (a) Applicable Construction Code and Class: ASME B&PV Code Sect. I11,1965 Edition, Winter 1967 Add; Class

()- e l Appi-bCCases: 1335-2, 1336, R p,. . .

1359-1

. ;A plcable Sect XI Ed. forRej is/Rpacem~nt (b -Q ......... 1998 Edition iL.

6. Identification of Components Repaired or Replaced and Replacement Co nponents: ASME Repaired, -Code Manufacturers National Other Year Replaced,'of Stamped Name of Name of -Built 'Replacemen (Yes or No)

Serial Number' Board No.' Identificatioii Componet Manufactudrer Repaired/Repi Yes Unit One Reactor Vessel and Head 1971 Repalred/Repl Yes Pressure Vessel "Combustlon " Vessel SN: 67107 20911 -1 aced Engineering Head SN: 67207 2001 Replacement No 0200101511 405132/ N/A Plug, Incore Detection Seal, Dwg.

Plug BGE CCNPP Shops 001 thru 009 12148-03,ASTM-A276, Ty316 SS

7. Description of Worlc This plan was for the installation of dummy stainless steel ICI plug(s) into Unit #1 Reactor Vessel In Core Instrumentation Flanges.
8. Tests Conducted: Hydrostatic:[] PneumaticOl Nominal Operating Pressure: Inservice: fl Leakage RJ Functional. El Test Temperature: 530 Deg. F Pressure: 2250 psi.

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

numbered and the (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section Xl VT-1 Visual Examination of the replacement threaded fasteners was performed to satisfy Section XI Pre-Service NDE Requirements. A Section XI System Leakaqe Test of the affected component was performed durinq the system conditions listed in section 8. of this report.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Repair/Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H. Ballard

-.... . ... ... .Ce~tifi-c-atf -of Iniw'ice-Inspe ction ... . .. - .... ... . .

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components described in this Owner's Report during the period /- 4"-0d ..- to 7-2'--0. Z , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

Commissions: ns g2tuNn &or, /tt ,MdE Ing't/spe igatr National Board, State, and Endorsements 9ýE 1 200oZ_

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section XI

1. Ownfer: .... Calvert Cliffs Nuclear Power Plant, Inc. te - 7/2002 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet1 of'2 '

. .. .. -- (address) . " . . . . . . .. . - . . . . .

2. Plant: Calvert Cliffs Nuclear Power'Plant' nit: One (name) -71 R&R No. 2001-1-079, MWO No.' 1200000999 1650 Calvert Cliffs Parkway; Lusby, MD 20657 (address) *"(P.O. no., job no, etc.)

Type Code Symbol Stamp: N/A

3. Work Performed by( Calvert Cliffs Nuclear Power Plant Dept. Authorization No.: N/A
  • (name)

Exp Date: 'N/A "Section XI Class:' Two 1650 Calvert Cliffs Parkway, Lusby, MD 20657 (address)

4. Identificaition of System: SystemNumber 052 .SystemName: Safety Injection-".

5.(a) Applicable Construction Code and Class: ASME B16.5, 1968 Edition, Steel Pipe Flanges and Flanged

-Fittings NPS--7 thru 24"&-CCase N-10 -* :."

(b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition,

6. Identification of Componefits Repaired or Replaced and Replacement Components: ASME Repaired, Code Manufacturers National S-Other Year "Replaced, oi Stamped Name of Name of Serial Number Board No. Identification Built "Replacemen (Yes or No)

Componet Manufacturer i- 0 SN: P34753-2 N/A #IIA Low Pressure Safety 1975 epaarewepi Repaired/Repl INo Valve Velan Enginnering aced Co. Injection to Reactor Coolant Loop 1999 Replacement Nut Nova Machine 38612 Heat Code: NIA Nut, Heavy Hex, 1114 In.X 8 No Products Corp. FSD' TPI, ASME SA-194 Gr. 7' Disc, Velan, Item No. 3 Dwg. 2001 Replacement No Disc Velan Valve 405030 SN: 7569 N/A Corporation 12124-0002, SA-182 F-316 S.S. for Velan 6"/15001b. Check Valve -

7. Description of Work:

This plan was for the maintenance work on I-CKVSI-1 14, #1 1A Low Pressure Safety Injection to Reactor Coolant Loop, replace valve disc and nuts.

8. Tests Conducted: Hydrostatic [] PneumaticC] Nominal Operating Pressure: Inservice:I] Leakage. E] Functional E]

Pressure: N/__.A psi. Test Temperature: N/..A Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

I -______

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

No Section XI Pre-Service NDE was performed in support of this activity. The replacement valve wedqe/plup/disc/trim received a Construction Code Surface Examination at the request of the resident ANII.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this RepairlReplacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date- N/A Charles H Ballard Signed: Engineering Technician Date: 7/31/2002 Owner or Owner's besignee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components described in this Owner's Report during the period Z-ZI -o . to 7-19--0 Z- , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures descnbed in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

LAIns tosSgaueNational NatiaCommissions:

oa&dZ-2

,SA anJ d *ndors Board, State, an~d Endorsements 96aý5 200.

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section XI

1. Ow*ner: ' Calvert Cliffs Nuclear Power Plant, Inc. "* Date:, -711212002 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657- SSheet I of 2

. . . (ad dress) ... S..

Calvert Cliffs Nuclear Power Plant Unit: One

2. Plant:

(name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2001-1-080, MWO No. 1200000998 (address) (P.O. no, jobno., etc.)

Type Code Symbol Stamp: N/A

3. Work Performed by. Calvert Cliffs Nuclear Power Plant Dept. Authorization No.: N/A (name)

Exp Date: N/A Section XI Class: Two 1650 Calvert Cliffs Parkway, Lusby, MD 20657 (address)

4. Identification of System: , System Number 052 SystemName: Safety Injection 5.(a) Applicable Construction Code and Class: ASME B16.5, 1968 Edition, Steel Pipe Flanges and Flanged Fittings NPS 1/2" thru 24" & CCase N-10 (b) Applicable Sect XI Ed. for Repairs/Replacement 'I19 Edition
6. Identification of Components Repaired or Replaced and Replacement Components: ASME "Repaired, 'Code

. ,. Other -Year Replaced, or Stamped Name of -- Name of " Manufacturers 'National Board No. Identification Built Replacement ' (Yes or No)

Componet . Manufacturer Serial Number tepaired/Repi Yes Valve Velan Enginnering SN: 0627 N/A #1iB Low Pressure Safety 1975 - I epared/Repl Yes Injection to Reactor Coolant Loop need Co.

In. X 8 1999 Replacement 38612 Heat Code: N/A Nut, Heavy Hex, 11/4 No Nut Nova Machine Products Corp.. - FSD "-, "TPI, ASME SA-194 Gr. 7 - ---

1999 -Replacement Rod Nova Machine 38454 Heat Code: N/A Rod, Allthread, 11/4 In. X 8 TPI, No NBW ASME SA-193 Gr. B7 Products Corp.

1998 Replacement Rod Allied Group 27260 Heat Code: N/A Rod, Allthread, 11/4 In. X 8 TPI, No

- P35 - -- ASME SA-193 Gr. B7 2001 Replacement No Disc Velan Valve 405030 SN:7570 N/A Disc, Velan, Item No. 3 Dwg.

Corporation 12124-0002, SA-182 F-316 S.S. for Velan 6"11500[b. Check Valve

7. Description of Work:

This plan was for rebuilding 1-CKVSI-124, #11B Low Pressure Safety Injection to Reactor Coolant Loop, and replacing valve disc and fasteners.

8. Tests Conducted: Hydrostatic:[-- Pneumatict] Nominal Operating Pressure: Inservice: I] Leakage:E] Functional [L Pressure: N/.A psi. Test Temperature: N/A Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

-_____I-- -______

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

No Section XI Pre-Service NDE was performed in support of this activity. The replacement valve wedqe/lplu/qdisc/trim received a Construction Code Surface Examination at the request of the resident ANII.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this RepairlReoplacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H. Ballard Signed: Engineenng Technician Date: 7/12/2002 Owner or Owner's Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components described in this Owner's Report during the period : 7--/ /- '.. to a-/?--OZ_. , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described m this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

Commissions: ,2) /

Inspu National Board, State, and Endorsements Dat /4, 200 Z..-

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section XI

1. Owner:Mae 1Calvert Cliffs Nuclear Power Plant, Inc.-  ;-Dt: 711712002 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 ,-Sheet 1 of 2

. (address) .

2. Plant: Calvert Cliffs Nuclear Power Plant Unit: One (name) t, 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2001-1-081, MWO No. 1200000997 (address) - (P.O. no job no., etc.)

SType Code Symbol Stamp: N/A

3. Work Performed by: Calvert Cliffs Nuclear Power Plant Dept. Authorization No.: N/A (name)

Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 SSection XI Class: Two (address)

4. Identification of System: System Number 052 SystemNName: Safety Injection 5.(a) Applicable Construction Code and Class: ASME B16. 5, 1968 Edition-, Steel Pipe Flanges and Flanged Fittings NPS 11/2" thru 24" & CCase N-I0 (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition
6. Identification of Components Repaired or Replaced and Replacement Components: I- ... -_ ASME

"- Repaired, Code Manufacturers National Other Year Replaced, oi -Stamped Name of -Name of Componet Manufacturer Serial Number Boar'd No. Identification "-Built Replacemen (Yes or No)

Repaired/Repi No Valve Velan Enginnering UEI: 1-CKVSI-144 N/A #12B Low Pressure Safety 1975 No Injection to Reactor Coolant Loop - aced Co.

2001' Replacement No Disc Velan Valve 405030 SN:7568 N/A Disc, Velan, Item No. 3 Dwg.

Corporation 12124-0002, SA-182 F-316 S.S. for Velan 6"/15001b. Check Valve

7. Description of Work:

This plan was for the maintenance work on 1-CKVSI-144, #12B Low PressureSafety Injection to Reactor Coolant Loop, replace valve disc.

8. Tests Conducted: Hydrostatic-[:] Pneumatic-] Nominal Operating Pressure: Inservice E] Leakage:E] Functional:[D Pressure: N/A psi. Test Temperature: N/.AM Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x I1 in.,

(2) inf6iiiiio hrough 6 on this report is included on each-she-et, an-d-(3)-each-l-et-inmb-e-red-an-th-e t-i-niFerns number of sheets is recorded at the top of this form.

I Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

No Section Xl Pre-Service NDE was performed in support of this activity. The replacement valve wedge/plug/disc/trim received a Construction Code Surface Examination at the request of the resident ANII.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Repair/Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A

    • /'* *"/'* **
  • _L_*'/

J/ECharles H. Ballard Signed: Engineering Technician Date:

r 7/17/2002 or Owners Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components described in this Owner's Report during the period -Z- Z 1 --0 Z to & -Z.* -o K.. , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

Inspecto__SgnaturCommi-ssions: A NatZZio -oard . E ec,)

em Inspector's Signature National Board, Stateý' and Endorsements Date / 200 Z.

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section XI

1. Owner: ' ' Calvert Cliffs NuclearPower Plant, Inc. -Date: 7117/2002 .

(name) 1650 Calvert Cliffs-Parkway; -Lusby, MD-20657--.-, - -- -  :- -Sheet-I of-2 -  :- - - - - - - - - - - - - - -

S. . . .. .(address)

Calvert Cliffs Nuclear PowerPlant unit: . One

2. Plant:

(name)

R&R No. 2001-1-082, MWO No. 1199802485 1650 Calvert Cliffs Parkway; Lusby, MD 20657 (address) (P.O. no. job no , etc.)

3. Work Performed by: Calvert Cliffs Nuclear Power Plant Dept.' Tye Code Symbol Stamp: N/A (nme WrPAuthorization No.: N/A

( Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Glass: - One (address)

4. Identification of System: System Number 052 SystemName: Safety Injection 5.(a) Applicable Construction Code and Class: ASME B16.5, 1968 Edition, Steel Pipe Flanges and Flanged Fittings NPS 1/2" thru 24" & CCase N-10 (b) Applicable Sect.XI Ed. for Repairs/Replacement, 998 Edition
6. Identification of Components Repaired or Replaced and Replacement Components: ASME Repaired, -Code 998 Edition oi' Stamped National Replaced, Name of "Nameof Manufacturers Otiiear ' YearBuilt Serial Number Board No. "Identification Replacemen (Yes or No)

Componet Manufacturer 1975 RepaIred/Rep! No Valve Velan Enginnering SN: 903234 N/A #11B Reactor Coolant Loop 1975 -Repalred/Repl No Sarety Injection Inlet Check Valve aced Co.

N/A Disc, Velan, 12 In. 1500 lb. Check -2002 Replacement *No Disc Velan Valve 404387 SN: 7560 SCorporatlon "Valve,ASME SA-1 82, Tp. F316, Drwg. 12124-0001, Item #3 i

7. Description of Work:

This plan was for the maintenance work on 1-CKVSI-227; replace valve disc.

8. Tests Conducted: Hydrostatic:[] Pneumatic]" Nominal Operating Pressure: Inservice: E] Leakage [] Functional: E]

Pressure: N/A psi. Test Temperature: N/._AA Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the numiber of sheets is recorded-aft e to-p- orthisform.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

No Section Xl Pre-Service NDE was performed in support of this activity. The replacement valve wedge/plug/disc/trim received a Construction Code Surface Examination at the request of the resident ANII.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Repair/Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A ExpirationDate: N/A Charles H. Ballard Signed: *

  • Engineering Technician Date: 7/17/2002 Owner or Ownees Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components described in this Owner's Report during the period - to , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

SCommissions: e/?.2_e Ad, -. / 6/ /7 Inspector's Signature National Board, State, and Endorsements Date:`Q4u L 200Q

FORM NIS-2 OWNER'S REPORT FOR REPAIR I REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xl calvert Cliffs Nuclear Power Plant, lnc.

C- Date: 7117/2002

1. Owner:

(name) 1650-Calvert Cliffs Parkway; Lusby, MD 20657 Sheet I of 2 (address)

. .Unit: --- One

2. Plant: - Calvert Cliffs Nuclear Power Plant (name) .

R&R No. 2001-1-083, MWO No. 1200103149 1650 Calvert Cliffs Parkway; Lusby, MD 20657 (P.O no.,job no, etc)

(address)

Type Code Symbol Stamp: N/A

3. 3WorkPerformedby:.Calvert Wr efre y Cliffs Nuclear Power Plant Dept. Authorization No.: N/A (name) Exp Date: N/A Section XI Class: One 1650 Calvert Cliffs Parkway, Lusby, MD 20657 (address)

SystemNumber 052 - SystemName: Safety Injection

4. Identification of System:

5.(a) Applicable Construction Code and Class: ASME B16.5, 1968.Edition,-Steel Pipe Flanges and Flanged Fittings NPS 1/2" thru 24" & CCase N-a (b) Applicable Sect XI Ed. for Repairs/Replacement S. ,- 1998 Edition

6. Identification of Components Repaired or Replaced and Replacement Components:
  • Repaired,
ASME Code Year Replaced, ol Stamped Name of Name of Manufacturers, Nationl-" Other Built Replacemen (Yes or No)

Componet Manufacturer Serial Number Board No. -, Identification RepaIred/Rep! No SN: 9903234 N/A . #12A Reactor Coolant Loop. 1975 .Repaired/Repi aced.

Valve Velan Enginnering Safety Injection Inlet Check Valve Co. "Replacement No 404 387 SN: 7561 N/A Disc, Velan, 12 In. 1500 lb. Check 2002 Disc Velan Valve Valve, ASME SA-182, Tp. F316, -.

Corporation Drwg. 12124-0001, Item #3 No 105 -Replacement 523-GX Heat N/A Stud, Cover, 17/81n.XSTPI, - 1995 Stud Velan Engineering Co. Code: F3 ASME SA-193 Gr.B7, 12 In. 1500 lb. Check, Drwg. 12124-0001, item

  1. 18 -t

-No-...

90247-GX Heat N/A "'Nut, Hex, Cover, 17/8 In. X 8 - - 1994 Replacement Nut Velan Engineering -

TPI, SA-194 Gr7, 12 in, 1500 lb.

Co. Code: VS0 Check, Drwg. 12124-0001, Item

  1. 17
7. Description of Work:

This plan was to cover maintenance work on 1-CKVSI-237; replace valve disc and bolting.

Pneumatic{j Nominal Operating Pressure. Inservice" [] Leakage:E] Functional: E

8. Tests Conducted: Hydrostatic

N/..A psi. Test Temperature: N/.A Deg. F Pressure:

in. x 11 in.,

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 is numbered and the (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section Xl VT-1 Visual Examination of the "NEW" threaded fasteners was performed prior to installation to satisfy Section Xl Pre-Service NDE Requirements. (LTP: 137800) The replacement valve wedqe/pluq/disc/trim received a Construction Code Surface Examination at the request of the resident ANII.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this RepalrlReplacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A S/ Charles H. Ballard Signed: Engineering Technician Date: 7/17/2002 6w-r or Owneers Designe&e, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components described in this Owner's Report during the period 2-- //-- --- to 4. "-Zý-- 2. , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

gntrCommissions: NatiZ4al, ArdL S ata Edrmn lnspeto s-Signature National Board, State, and Endorsements Date: 200 Z-..

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions ofthe ASME Code Section XI

1. Owner: ' Calvert Cliffs Nuclear Power Plant, Inc. Date: 711512002 - --

(name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheetlof 2 (address)

2. Plant: Calvert Cliffs Nuclear Power Plant Unit: One ,

(name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2001-1-084, MWO No. 1200103150 (address) " (P.O. no ,job no , etc.)

"TypeCode Symbol Stamp: N/A

3. Work Performed by: Calvert Cliffs Nuclear Power Plant Dept. Authorization No.: N/A (name)
  • Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class: One (address)
4. Identification of System: System Number 052 SystemName: Safety Injection 5.(a) Applicable Construction Code and Class: ASME B16.5, 1968 Edition, Steel Pipe Flanges and Flanged Fittings NPS l/2"-thru 24" & CCase N-10 (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition
6. Identification of Components Repaired or Replaced and Replacement Components: ASME' Repaired, Code' Other Year Replaced, or Stamped Name of I Name of "Manufacturers National. (Yes or No)

Board No. Identification - Built Replacement Componet Manufacturexr Serial Number No Valve Velan Enginnering 1-CKVSI-247 N/A #12B Reactor Coolant Loop 1975 Repaired/Repi Safety Injection Inlet CheckValve aced Co.

Disc, Velan, 12 In. 1500 lb. Check 2002 Replacemer nt No Disc , - Velan Valve 404387 SN: 7558 N/A Valve, ASME SA-182, Tp. F316, Corporation Drwg. 12124-0001, Item #3

7. Description of Work:

This plan was'for the replacement of the disc on 1-CKVSI-247, #12B Reactor Coolant Loop Safety Injection Inlet Check Valve.

8. Tests Conducted: Hydrostatic E] PneumatieO Nominal Operating Pressure: Inservice" I] Leakage: E] Functional. []

Pressure: N/.A psi. Test Temperature: NIA Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (I) size is 8-1/2 in. x 11 in.,

(2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

No Section XI Pre-Service NDE was oerformed in suVoort of this activity. The reolacement valve wedae/olua/disc/trim received a Construction Code Surface Examination at the reauest of the resident ANII.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Repair/Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A j Charles H. Ballard Signed: Engineering Technician Date: 7/15/2002 Owýner orOwner's Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components described in this Owner's Report during the period Z - /, 1-0. to ,- , -- , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report m accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

I&4f*--I?- Commissions: 4~/~eA/Mr A-iZ A17 National Board, State, and Endorsements I&ipcto' Signature' Date:rstgatr 2oardZtt5adEnosmns Naioa

' JFORM

_ NIS-2 OWNER'S REPORT FOR REPAIR I REPLACEMENT ACTIVITY As Required Required by the Provisions'of the ASM4E Code Section XI S. . Calvert Cliffs Nuclear Power Plant, Inc. Date: -. 712512002

1. Owner: (name) . ,

Sheet I of 2 1650 Calvert Cliffs Parkway; Lusby, MD 20657 (address)

"---Calvert Cliffs Nuclear Power Plant " Unit:- -one - -

2. Plant:

. . . . (name)

R&R No. 2002-1-002a, MWO No. 1200002340 1650 Calvert Cliffs Parkway; Lusby, MD 20657" (address) (P.O. no job no, etc.)

Calvert Cliffs Nuclear Power Plant Dept. Type Code Symbol Stamp: N/A

3. Work Performed by:

(name) " Exp Date: N/A Authorization No.:-, N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class: One 041 System Name: Chemical Volume Control

4. Identification of System: "System Number 1970 5 .(a) Applicable Construction Code and Class:.. ASME Draft Code for Pumps & Valves, 1968 Edition, March SAdd; Class -One -

1998 Edition (b) Applicable Sect XI Ed. for Repairs/Replacement

6. Identification of Components Repaired or Replaced and Replacement Components: ASME

-Repaired, -- ,Code I er Year ,Replaced, oi Stamped Name of - Manufacturers National -0t Name of cation' z Built Replacemefn (Yes or No)

Componet Manufacturer Serial Number Board No. Identifi RepaIred/Rep! aes Valve Bechtel SN: 2093 "N/A #11 Regen .Heat Exch. Check ' . 1975 Repaired/Repl aced L P

Xes Valve to #12B RCS Cold Leg Loop 1996 Replacement Yes L10041NP SN: N/A Valve, Check, 2 in. 2680 lb.,Butt Check Valve Velan Engineering T 961027-1 Weld, ASME SA-182, p F316, Co. Velan Dwg 12968-0138

7. Description ofWork:

Valve to This plan was for the replacement of 1-CKVCVC-1 86, #11 Regenerative Heat Exchanger Check

  1. 121 Reactor Coolant Loop.

Inservnce" [] Leakage:R] Functional'[

8. Tests Conducted: Hydrostatic L- Pneumatic-] Nominal Operating Pressure 2250 psi. Test Temperature: 530 Deg. F Pressure:

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

and the (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section XI System Leakage Test of the affected component was performed during the system conditions listed in section 8. of this report. Code Case N-416-1 was invoked to satisfy Section XI required pressure tests. Addtional Section III Examinations were performed (as applicable) to satisfy Code Case N-416-1 and Reg.Guide 1.147.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Repair/Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H. Ballard Signed:

  • Engineenng Technician Date: 7/25/2002 Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components described in this Owner's Report during the period Z - _i - 0 Z, to 7-/ 7- , _2 , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures descnbed in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind ansing from or connected with this inspection.

National Board, State, an8 Endorsements Date:G _ iS 200Z__

DATA PACKAGE NO. 961027 P.6 PUMPS OR VALVES

  • FOI4RM IPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR III, Division I Code, Section

'As Required by the Provisions of the ASME

-Pa:o3. 'of I. Manufactured and certified by-- VELAN INC. 2125 WARD AVE-MONTREAL CANADA H4MIT6 (name and address of N Certificate Holder) MD. 21203

2. Manufactured for BALTIMORE-GAS-& ELECTRIC' P.O. -BOX -1472 BALTIM0RE, .

2 (name and address of purebaser) - -

MD, 20657

3. Location of installion IVERT CLIFFS NUCLEAR PLANT-NORTH OF LUSBY.

(name and address)

Drawing -PI-76800-N28 Rev D CRXý N/A

4. Model No., Series No., or Type: PS-CHEC 199 NONE 1 N/A 5, ASHE 'Code,Section III, Division 1: -,-(addenda date) - (class)_, (Code Case no.)

- (edition) 2" Outlet size 2"

6. Pump or valve VALVE -Nominal-inlet size (in .) .-.. . .- 1 (in .)

SA-182,F316 Disk SFA 5.13 RNiCr-A Bolting N/A 7*. Material: Body SA-182,F316 Bonnet (c) (d) (COL*4

"__ (b) (C)(d(e Bonnt LJ.bJ Cert. ..-N at 'lý ', Body . . "*- Bonnet Serial . -- UISK Serial

- - Board Serial -F

- No. ",

Holder's No.S No'.

Serial- No. -

H/C:26A ...

H/C: lARA '

N/A H/C: B16 961027-1 I

may be used provided (1) size is 8 top 112 x 11, (2) inforaton in itm I thouh 4 on ths Dat Report

Supplemental information in form of lists, sketches, or drawings number of sheets is recorded at the of this form.

"Isincluded on each sheet, (3) each sheet is numbered and the LAW DRIVE< BOX 2300 Fairfield, NJ 07007-2300.

1(12188) This form (E00037) may be obtained from the Order Dept., ASME, 22 NOTE. DWG-Pl-76800-NS0REV.0

2 of 2 ) P.7 FORM NPV-1 (Back - Pg.

Certificate Holder's Serial No. 961027 6430 psi 100 OF or valve pressure class 2680 (1)

8. Design conditions (pressure) (temperature)
9. Cold working pressure 6430 psi at 100OF
10. Hydrostatic test 10050 psi. Disk differential test pressure 7375 psi
11. Remarks: MATERIALS MEET ASME SECTION II EDITION: 1989 ADDENDA: NONE CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this pump or valve conforms to the rules for construction of the ASME Code, Section III, Division 1.

N-2797-1 Expires MAY 2,98 N Certificate of Authorization No.

Date 41 a Name VELAN INC. Signed f*

(NCertificate Holder) aprestntative)

(authorized CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler QUEBEC and and Pressure Vessel Inspectors and the State or Province of the pump, or employed by PROVINCE of OUEBEC have inspected valve, described in this Data Report on qf'(ot5/o 5 , and state that to the or best of my knowledge and belief, the Certificate Holder has constructed this pump, valve, in accordance with the ASME Code, Section III, Division 1.

By signing this certificate, neither the inspector nor his employer makes Data any warrenty, implied, concerning the component described in this Report.

expressed or any manner for Furthermore, neither the inspector nor his employer shall be liable in any personal injury or property damage or a loss of any kind arising from or connected with this inspection. BEN01-1 FF,,A ATTE Date%* 0),3 signesC41,.1 W.JV.4 Commi sionL,, ..

iT P1 A*#-hBN ETT EjnkLI k^UUW PýLr tate or prov. and no.)

(1) For manually operated valves only.

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Require'd by the'Provisions of the AS-ME Code Section XI

1. Owvner: Calvert Cliffs Nuclear Power Plant, Inc.-,- - Date 7/19/2002

-- (name) , .

1650 Calvert Cliifs Parkway; Lusby, MD 20657 Sheet I of 2 (address)

2. Plant: Cal~vert li I..DIII I'UIdc u 0Vw1IjIcIL -unit: -Une -

- ~~~(name) - . .

1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No':2002-1-002b, MWO_ No.- 1200002340 (address) (P.O. no., job no , etc.)

)ept. Type Code Symbol Stamp: N/A erfrmeby:Calvert Cliffs Nuclear Power Plant 1

3. Wrk -Authorization No.: N/A I (name)

Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section )G Class: One (address)

4. Identification of System: -,SystemNumber 041 System Name Chemical Volume Control 5.(a) Applicable Construction Code and Class: _ASME 1331.7 1969 Edition, Summier 1971 Add; Class One (b)Applicable Sect XI Ed. for Repairs/Replacemc t ý-._, t_ ; - -:ý -1998 Edition
6. Identification of Components Repaired or Replaced and Replacement Components: ' ASME Repaired, Code Name of Name of -Manufacturers Nationa-Other `Year- Replaced, oi Stamped Componet Manufactuýre Serial Number' Boaýrd No:- Idirtification Built Replacemen EYe's -orNo)

Piping System Bechtel 2"1CC-5-1004 N/A From #11 Regen. Heat Exch. to 1975 RepairedfRepi No

  1. 12B RCS Cold Leg Loop -aced Pipe Consolidated 20439 Heatff4471 N/A .Pipe, 2 In.Schedule 160, ASME 1998 Replacement .No Power Supply XBJ SA-376 Tp. 316
7. Description of Work:

This plan was for the replacemnemt of piping durning the replacement of 1-CKVCVC-186:

8. T~sts Conducted: Hydrostatic-[ Pneumatics Nominal Operating Pressure- Inservice E] Leakage:~ Functional. El Pressure: -- 250 psi. .- Test Temperature: __53 __Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

I-Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section Xl System Leakage Test of the affected component was performed during the system conditions listed in section 8. of this report. Code Case N-416-1 was invoked to satisfy Section Xl required pressure tests. Addtional Section III Examinations were performed (as applicable) to satisfy Code Case N-416-1 and Req.Guide 1.147.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Repair/Roplacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A SCharles H. Ballard Signed. Engineering Technician Date: 7/19/2002

--DCwnero0 ý .&s Designe-e.Title i Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston. RI have inspected the components described in this Owner's Report during the period Z-Z-( -O Z*. to 7- / 7--o 7. , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection "L Us-oo trCommissions: 1 at13 Boar, Stat Edrm '

Inspector's Signature National Board, State, land Endorsements Date ý 200 2_

6'/

ACTIVITY FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT XI As Required Required by the Provisions of the ASME Code Section Calvert Cliffs Nuclear Power Plant, Inc. -Date: 7116/2002.

1. Owner:

(name) 1650 Calve-t Cliffs Parkway; Lusby, MD 20657 SSheet I of 0 (address)

Calvert Cliffs Nuclear Power Plant Unit: One

2. Plant:

(name)

R&R No. 2002-1-003, MWO No. 1200200048 1650 Calvert Cliffs Parkway; Lusby, MD 20657 (P.O no.,job no, etc.)

auurcj Type Code Symbol Stamp: N/A Calvert Cliffs Nuclear Power Plant Dept. Authorization No.: N/A

3. Work Performed by:

(name)bx I/ t" A Secxp ate:

"-Section XII Class:

/.ClA- Tw Two 1650 Calvert Cliffs Parkway, Lusby, MD 20657 SystemNumber 041 System Name: Chemical Volume Control

4. Identification of System:

5 .(a) Applicable Construction Code and Class: ASME B31.1.0' 1967 Edition, 1972 Add 1998 Edition (b) Applicable Sect XI Ed. for Repairs/Replacement

6. Identification of Components Repaired or Replaced anid Replacement Components: ASME

-Code "Repaired, Stamped Year. Replaced, or or No)

Manufacturers "National S" 'Other (Yes Name of Nar~e of ~.qria1 Number "- "Identification Built Replacement Alfsmir~pr Board No.-

Compoet Srial um/e No

  1. 11 Steam Generator Bottom 1975 Repaired/Repl No Bechtel 2"EB-6-1007 N/A aced Piping System Blowdown to #11 Blowdown Tank Nut, Heavy Hex, 1/2 In. X 13 TPI, _2002 Replacement -No Mackson Inc. 406241 HL #Y67408 N/A -

Nut SA-194 Gr. 2H -

Grinnell 79546-GX Ht.# 5105 N/A Clamp, Pipe Anchor, 2 in. for PG- 1993 "Replacement Pipe Clamp 41 1 PG-43, per Drwg.# FSK-MP No Corporation 05715H0003 & 0005, Part# 1.

N/A Ciamp, Pipe An*chor Base, 2 In. .... 1994 -Replacement No Pipe Clamp Grinnell 47477LNP for PG-41 I PG-43 per3 Drwg.#

Base Corporation FSK-MP-0571SH000 & 0005, Part# 5.

N/A Bolt, Heavy Hex. Head, 1/2 in. X 2 1994 Replacement No Bolt Cardinal Ind. 88627-GX Heat In. X 13 TPI, ASME SA-193, Gr.

Products Code:L7 A4 B7 NIA Tube, Steel, 2 in. X 2 in. X 1/4 in., 2001 Replacement No DuBose National 400428 Heat Code:

Tube Steel 13594 ASTM A-500 Gr. B No Energy Services Inc.

402888 Ht.#642767 N/A Bar, Flat, 4 In. X 1/2 In., ASME 2001 Replacement Fiat Bar Energy Steel & SA-36 Supply Co.

7. Description of Work:

on line 1#EB-6-1007.

This plan was needed to correct the Design deficiencies on Anchor #10 Nominal Operating Pressure' Inservice: [] Leakage:E] Functional:E]

8. Tests Conducted: Hydrostatic'l PneumaticO]

Test Temperature: N/._AJ Deg. F Pressure: N/..A psi.

size is 8-1/2 in. x 11 in.,

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)

(3) each sheet is numbered and the (2) information in Items 1 through 6 on this report is included on each sheet, and number of sheets is recorded at the top of this form.

l Sheet.of 1L FORM NIS-2 (Back)

9. Remarks:

No Section XI Pre-Service NDE was performed in support of this activity.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Repair/Replacement conforns to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A I Charles H. Ballard Signed: Engineering Technician Date: 7/16/2002 er's oesine! W/ ngnerngTchica Ownr;&or Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components described in this Owner's Report during the period Z-lO - CZ, to . -f3--o Z.. , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

-Commissions: "J a' -24'*:

oard. SnD "Ins~or'sSigntureNational Board, State, arnd Endorsements Date-:(%Le.4 /el_ 200 .-

FORM NIS-2 OWNER'S REPORT FOR REPAIR I REPLACEMENT ACTIVITY As Required Required by the'provisions of the ASME Code Section Xl

1. Ower: Calvert Cliffs Nuclear Power Plant, Inc.- Date-: 81812002 (name) - . -

1650 Ca-lVert Cliffs Parkway; Lusby, MD 20657 . .Sheet " Io." -2

'*'- ., . -(address) - - " "  :; - " - "

_2..Pla-fl . Calvert Cliffs Nuclear.Power Plant - , -. Unit:, One,%i- A J-. , _ .

_- (name)

"1650 Calvert Cliffs Parkway; Lusby, MD -20657 '.R&R No. 0

-T

- -" (address) - .. . "(P.O. no.,job no, itc.)

Calvert Cliffs Nuclear Power Plant De0t.;T- yinI-aip /

S-3. Work Performed by: C AuthorifftNonlNo.- N/A (name) . r

,- .ExpDate: N/A ,

1650 Calvert Cliffs Parkway, Lusby, MD 20657 - - [Section XI Glass: TWo i (address)

4. Identification of System:" "Sse ~ mbr -45  : . .S tri a , e dwater....

e'-. . .... . . ..

4. ystm:_SystemNumber 045Feewtr 5.(a) Applicable Construction Code and Class: 'ASMEB31.I;0 :1967 Edition,-1972 Add"; -- .--

(b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition

6. Identification of Components Repaired or Replaced and Replacement Components: ASME "Year Repaired, Code Replaced, o1 Stamped Name of Manufacturers National 'Other' Name of "- Built Replacemen (Yes or No)

Manufacturer Serial Number Board No. Identification Componet 1975 - RepairedlRepl No Valve Rockwell 025 N/A #11 Steam Generator Feedwater 1975 , Repaired/Repl No Supply Check Valve -- , aced "

International NIA Screw, Hvy Hex Hd,16 In. Check 2000 -Replacement No Screw Edward Valves Inc. 400813 Heat Code:

- Valve, Edwards Fig. 970Y, A-193 So1031 Gr. B7,Drwg.12399-0002/0022 Item #12

7. Description of Work: ...

This plan was to allow the use of the part listed herein to assist in the rebuilding of 1-CKVFW-1 33, #11 Steam Generator Feedwater Check Valve.

8. Tests Conducted: Hydrostatic ] PneumaticG] Nominal Operating Pressure: Inservice" L] Leakage: E] Functional: E]

Pressure: N/A psi. Test Temperature: N/.A Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

No Section Xl Pre-Service NDE was performed in support of this activity.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Repair/Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A ExpirationDate: N/A Charles H.Ballard Signed: Engineenng Technician Date: 8/8/2002 Owner or Owner's Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components described in this Owner's Report during the period 3 - ZC-,o 0Z. to &--/7-/ *. , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report m accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

Zn Natioia AAJLrta4ed Inspecto s Wiatur-e National Board, State'and Endorsements Dat w* -.q 200 Z_.

61

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the' Provisions-of the ASME Code Section XI

1. Owner:

Calvert Cliffs Nuclear Power Plant, Inc. Date: 711912002 (name) ...... .

1650 Calvert Cliffs Parkway; Lusby, MD 20657 . Sheet I of 2 .

(address)

2. Plant: Calvert Cliffs Nuclear Power Plant Unit: >,One (name) 1650 t Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2002-1-017, MWONo. 1200201261 (address) (P.O. no ,job no , etc.)

Type Code Symbol Stamp: N/A SW Performed 3.Work oCalvert by: Cliffs Nuclear Power Plant Dept. Authorization No.: N/A (name)

Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 - SectiohnXI Class: Two (address)

4. Identification of System: SystemNumber .083 System Name: Main Steam & SG Blowdown 5.(a) Applicable Construction Code and Class: 'ASME'B31.7 1969 Editionl, Summer 1971 Add; Class Two.

(b) Applicable Sect XI Ed. for Repairs/Replacement -mia coition ASME i

6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired, Code Name of Name of Manufacturers - National Other, Year Replaced, oi Stamped 1 Serial Number Board No. Identific~ation Built. Replacemen (Yes or No)

Componet Manufacturer-BG & E NA N/A Steam generator bottom/surface 1975 Repaired/Repl No No Pipe Support aced blowdown gang support Replacement SPlate DuBose National, 400428 Ht.#: N/A Plate, Steel 1/4 In. ASME SA-36 -2001 Energy Services 1106933 No Inc.

Plate DuBose National 400428 Ht.#: N/A Plate, Steel 1/2 In. ASME SA-36 2001 Replacement No Energy Services 2107091 Inc. -

DuBose National 400428 Ht.#: D04009 N/A Plate, Steel, 3/4 In. ASME SA-36 2001 Replacement No Plate Energy Services Inc.

N/A Tube Steel, Square, 4 In. X 4 In. X 1999 Replacement No Tube Steel DuBose National 34557 Ht.#: B37679 Energy Services 114 In.; ASTM A-500 Grade B Inc.

7. Description of Work:

This plan was to add structural steel to modify existing multiple support in accordance with ES199601526 110, ECR 384.

8. Tests Conducted: Hydrostatic:-] PneumaticO" Nominal Operating Pressure: Inservice' El Leakage E] Functional [I Pressure: NIA psi. Test Temperature: NI..A Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

No Section XI Pre-Service NDE was performed in support of this activity.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Repalr/Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A

-,/ -7,A R.E. Cantrell Signed: . { Sr. Engineer Date 7/19/2002 Owner or Owner's Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components described in this Owner's Report during the period Z- .9-02_. to ,-IS-C Z- , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described m this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

" %U n t Sa-tu-No Commissions: Aa NaIr, St1ate, a /n ndo 6 "

Inspelctor's Signature National Board, State, and Endorsements Date: 0200 2-

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xl

1. Owner: -

Calvert Cliffs Nuclear Power Plant, Inc. Date: 818/2002 (name) -

1650 Calvert Cliffs Parkway; Lusby, MD 20657 ....... Sheet 1 of 2

.... . . (address) -

2. Plant: Calvert Cliffs Nuclear Power Plant Unit: 'One "

(name)

R&R No. 2002-1-019a, MWO No. 1200001375 1650 Calvert Cliffs Parkway; Lusby, MD 20657 (address) -. (P.O. no ,jobno., etc.)

Type Code Symbol Stamp: N/A

3. WorkPerformedby: Calvert Cliffs Nuclear Power Plant Dept. Authorization No.: N/A (name)

,ExpDate: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 SSectior XI Class: Two (address)

4. Identification of System: SystemNumber 052 _SystemName:_ýSafety Injection March 1970 5.(a) Applicable Construction Code and Class:" ASME Draft Code'for Pumps & Valves,'1968 -Edition, "Add;Class Two I - -

(b) Applicable Sect XI Ed. for Repairs/Replacement - 1998 Edition -

ASME

6. Identification of Components Repaired or Replaced and Replacement Components:

"Repaired, Code Manufacturers Other Year Replaced, oi Stamped

,Nameof Nameeof National _

Serial Number BoardNo. Identificatic n Built Replacemen (Yes or No)

Componet Manufacturer Yes N/A Unit #1 Containment Sump WVest 1975 Repaired/Rep Yes Valve Velan Engineering aced Co. ... . Recirculation Header Isolation Valve No 407499 Heat Code: N/A Rod, Allthread, 11/4 In. X 8 TPI, 2002 Replacement Rod Mackson Inc."

ATX ASME SA-193 Gr. B8M, Cis. 2, Strain Hardened

- No Nut Mackson Inc. - -407499 Heat Code: "N/A- Nut, Heavy Hex;1 1/4 In. X 8 2002 Replacement ATY TPI, ASME SA-194 Gr. 8M, Strain Hardened

7. Description of Work:

This plan was to allow for all work, including fastener replacement, to rebuild 1-MOV-4145, Unit #1 Containment Sump West Recirculation Header Isolation Valve.

8. Tests Conducted: Hydrostatic El Pneumaticd Nominal Operating Pressure: Inservice" E] Leakage:E] Functional El psi. Test Temperature: N/A Deg. F Pressure: N/_.A NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

No Section Xi Pre-Service NDE was performed in support of this activity.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Repalr/Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H. Ballard Signed: Engineering Technician Date: 8/8/2002 neror Owner's signee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components descnbed in this Owner's Report during the period /--30-0'2.. to - and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

Commissions: Ie SBBZZneo Boar, te aE em tnspecA'intr National Board, State, and Endorsements Date: j-200 Z

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section XI

1. Owner:-` "--Calvert Cliffs Nuclear Power Plant, Inc. Date: "818/2002 - - - -:

(name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657-- - . 1 Sheetlof 2 - "

(address) .

Calvert Cliffs Nuclear Power Plant Unit:, One

2. Plant:

(name) 20657 R&R No. 2002-1-019c, MWO No. 1200001375 1650 Calvert Cliffs Parkway; Lusby, MD (address)  : - (P.O. no ,job no, etc.)

Type Code Symbol Starnp:, .N/A

3. Work Performed by: Calvert Cliffs Nuclear Power Plant Dept. Authorization No.: N/A (name)

\ E-.

xp Datý:,_ N/A"

\ - Section XI Class:" ,Two 1650 Calvert Cliffs Parkway, Lusby, MD 20657 (address)

4. Identification of System: S'stiffmNumber 052 System Name: Safety Injection 5.(a) Applicable Construction Code and Class: ASME B31.7 1969 Edition, Summer 1971 Add; Class Two

".1998Edition (b) Applicable Sect XI Ed. for Repairs/Replacement

6. Identification of Components Repaired or Replaced ahd Replacement Components: ASME Code Yea Repaired, Other Year- Replaced, oi - Stamped Name of Name of Manufacturers National Serial Number "BoardNo.' Identification Built Replacemen (Yes or No)

Componet Manufacturer L RepairecllKepl iNo }

Pipe Support Bechtel ' 24"HC-3 N/A Unit #1 Containment Sump West 1975 Repalred[Repl No Recirculation Header Support. aced 1001,H131R12

7. Description of Work: - - -- -:- I, This plan was for the work on 24"HC-3-1001; H13 / R12, Unit #1 Containment Sump West'Recirculation Header Support. A portion of the support was removed to allow for X-rays of the Encapsulation then reinstalled.
8. Tests Conducted: Hydrostatic ] PneumaticO] Nominal Operating Pressure Inservice.[] Leakage E] FunctionalElI Pressure: N/.A psi. Test Temperature: N/._A Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in Items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section XI VT-3 Visual Examination of the affected component support was performed prior to the system being returned to service.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance Repar/Rplacmen We certify that the statements made in this report are correct and that this RepairReplacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H. Ballard Signed: Engineering Technician Date: 8/8/2002

-owneror Owner's Designeetttle" A' Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components described m this Owner's Report during the period S-7-0 -... to Z-,--o

_- , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

/z!I Za-/ . tn' - Commissions: /UB  ? - 2 a AIJ*r A-l,) 6 117 Inspectbs Signature National Board, State, and Endorsements Dat 200 2.

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the 1Provisions of the ASME Code Section XI Calvert Cliffs Nuclear Power Plant, Inc. Date: 7118/2002

1. Owner:

1nay

. L..

1650 Calvert Cliffs Parkway; .Lusby, MD ,20657 Sheet I of-2 (address)

2. Plant: Calvert Cliffs Nuclear Power Plant Unit: ýOne, ,-

(name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. 2002-1-024, MWO No. 1200201762 (address) . P.O. no., job no., etc.)

Type Code Symbol Stamp: N/A

3. Work Performed by: Calvert Cliffs Nuclear Power Plant Di Authorization No.: N/A (name) [+_ Exp Date: N/._AA 1650 Calvert Cliffs Parkway, Lusby, MD 20657 SectionXI Class: - Two (address)
4. Identification of System: System Number 061 System Name: C6ntainmeiit Spray
5. (a) Applicable' Construction Code and Class: ASME Draft Code for Pumps & Valves, 1968 Edition, March'1970 Add; Class Two (b) tApplicable Sect XI Ed. for Rep'airs/Replacement " .. 9* )8 Edition
6. Identification of Components Repaired or Replaced and Replacement Components: " Repaired, ASME Code Name of Name of Manufacturers National Other "Year .Replaced, oi Stamped Componet Manufacturer Serial Number Board No. Identification' Built Replacemen (Yes or No) 1975 RepalredfRepl No Valve Masoneilan H-59104-5 N/A #11 Containment Spray Header-. 1995 Repaired/Rep] No Isolation Valve aced International Inc. 1990 'No 41449.GX SN: N/A Plug, 8 in. Masoneilan"Valve," Replacement

'Valve Plug Masonellan Dresser C/O A12421-6 ASTM A-479, Tp. 316, P/N:

Eastern Controls 013439-010-1N3

7. DescriptionofW ork: .. . . . . . . . . .

This plan was for rebuilding 1-CV-4150, #11 Containment Spray Header Isolation Valve.

8. Tests Conducted: Hydrostatic-f] Pneumatic3 Nominal Operating Pressure- Inservice" D] Leakage El Functional El Pressure: N/A psi. Test Temperature: N/.A Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

No Section XI Pre-Service NDE was performed in support of this activity.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance __Rpar/eplceen We certify that the statements made in this report are correct and that this Repair/Replaement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H. Ballard Signed: I IneenTechncian Date: 7/18/2002 Owner or Owner's Designee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components described in this Owner's Report during the period S- 21 -) 7-_. to 4,-24-01, .,and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures descnbed in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

spc) ors Snu"aa-rCommissions: ALE AJý- St2atr, Ano0e4t In'spector's s-ignature National Board, State, A~d Endorsements Date:*) ,ek  :?0. 200O.

FORM NIS-2 OWNER'S REPORT FOR REPAIR ! REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section XI 1.

I '.JwuuL. Calvert Cliffs Nuclear Power Plant, Inc." Date: .81512002 (name) 1650 Calvert Cliffs Parkway;. Lusby, MD: 20657 - - Sheet'I of 2 (address) Pl -- "

unt*.0 'ne

2. Plant: ~Cilve-rt Cliffs Nuclear Power Plant (name) 20657! " R&R No. SG-1-001a, ESP No. ES199601526 1650 Calvert Cliffs Parkway;: Lusby, MD (address) - - (P.O. no,job no., etc)

Calvert Cliffs Nuclear Power Plant Dept. Type Cod6 Symbol Stamp: N/A

3. Work"Performedby Authorization No.: N/A (name) " Exp Date: N/A 1650'Calvert Cliffs Parkway,- Lusby, MD 20657 --,Section XI Class: -One & Two .... ..

"(address) .- , -

4. Identification of System: System Number 64183 SystemName: Steam Generator Replacement 5.(a) Applicable Construction Code and Class: ASME B&PV Code Sect. 11l, 1965 Edition, Winter 1967 Add; Class A CCases: 1332-2, 13324359-1 -. -

1998 Edition (b) Applicable Sect XI Ed. for Repairs/Replacement

6. Identification of Components Repaired or Replaced and Replacement Components:. Repaired, ASME Code' Year Replaced, ot Stamped Name of Name of Manufacturers National Other Built Replacemen (Yes or No) on -.....

Conrionet "Manufacturer' -- SerialNumber BoardNo.-, -Identificati I Yes 1970 1970 Repaired/Rep' Repaired/Repl I

Pressure Vessel , Combustion CE 67504 20922 #11 Steam Generator Ipacedmn Engineering Replacement SYes Steam Babcock& 4621CCNP-21-9000 " 196 Steam Generator Lower 2001.,

SN: 7811-01 Assembly, Primary Side Head, Generator Wilcock Canad: Tubes and Secondary Shell up to Transition

7. Description of Worc ..

This plan was for the replacement of the primary side head, tubes; and secondary side shell u1 to'the and transition area of #11 Steam Generator. This also documents the reconfiguration ofithe Feed Nozzle Surface Blowdown Nozzle.

El Pneumatic-- Nominal Operating Pressure: Inservice: 0l °,Leakage: R] Functional: E]

8. Tests Conducted: Hydrostatic TestTemperature:--53 - F.:53

. Pres'suire: *890- .psi.-.:-

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

sheet, and (3) eachsheet is numbered and the (2) information in Items 1 through 6 on this report is in6luded on 6achi number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section X1 VT-1 Visual Examination of the replacement threaded fasteners was performed to satisfy Section XI Pre-Service NDE Requirements. A Section X1 System Leakage Test of the affected component was performed during the system conditions listed in section 8. of this report. Code Case N-416-1 was invoked to satisfy Section Xl required pressure tests. Addtional Section III Exarrminations were perforrmed (as applicable) to satisfy Code Case N-416-1 and Reg.Guide 1.147. A Section -XI Surface Examination, Eddy Currefit Examination and Ultrasonic Examination of the affected component was performed to satisfy Section Xl Pre-Service NDE Requirements. With an approved Relief Request from NRC, we were allowed to use the 1993 Addenda of the 1992 Edition of Section III. This addenda permits the use of wire type IQO's (image Quality Indicators) as an altemative to plaque type IQO's for radiographic examinations. Plaque type IQO's are required by Section III, 1992 Edition which is referenced by Code Case N-416-1 and by the installation code which is Section Ill, 1989 Edition.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Repair/Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A S7Charles H. Ballard Signed: Engineering Technician Date: 8/5/2002 OwnLer or Owner's Designee, tie Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components described in this Owner's Report during the penod Z-- //-) Z- to -7'- /0-0 Z7_ , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in thi Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

'Ž .d U,5"= Commissions: /J38* zZ,. A,&f /22) 61- 7 "nspec-rs Signature National Board, State, a'nd Endorsements D200 1--

,PG;Ft16ý2 CCIVI-- I FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES As Required by the Provisions of the ASME Code,Section III

. . Not to Exceed One Day'sProduction Pg. I of -4 P*.

anufactured and certified by Babcock & Wilcox Canada, 581 Coronation Boulevard, Cambridge, Ontario NIR 5V3 (name and addrsss of NPT Certicate Holder) ,

2. Manufactured for- SGT Ltd. P.O. Box 1219, Lusby, Maryland 20657 . " .

(nameand ad=3re*oPurchiser)

3. Location of Instarlation Calvert Cliffs Nuclear Power Plant (CCNPP) Units 1&2, .LusbV, Mailand 20657-4702 (name wd address),)
4. Type* 7811 001 Rev.6 -" See-attached List #1 -See List #1 -__ .__ ...... .. ... 2001

( whrg no.) (mnl. spme no.) -( 6 S.Irn't?*) (CRN) "yearbuilt)

5. ASME Code,Section II, DMslvo 1989: No Addenda 1 attachedno.)List #2 See(Code (editon) - (addeda date) e(class) Case
6. Fabricated In accordance with Const. Spec. (Div. 2 only) - Revislon -- " Date (no.)
7. Remarks: Secondary side hydrotest has not been performed. Post-hydrotest final NDE has hot been performed on" s econdary side. Previous N-2 form for primary head (National Board No. 402) attached.
8. Nom. thtckneis (in.) See List #3 Min. design thl*clness (in.) See List #3 D0a. ID(ft &Vn.)Sea List #3 Length (ft &in.) 39'-8 7/16" 1vrll
9. When eaplicable. Certificate Holders' Data Reports are attached for each Item of this report:

National

- Part orAppurtenance Board No. § Serial Number In Numerical Order (26)

(27)

(28)

(29)

(30) -_- __ __-" _-

(31)

(32) -- .. __ ___ ___ ,.._

(33)

(34)~

(35)

(36)

(37)

(38)

(39)

(40)__ _ _ _ _ _

(41)

(42)

(43)

(44)

(45)

(46)

(47)

(48)

(49)

(50)

F. Hydro. test pressure See LUst #4 at  !,Ir

  • applicable)

(when "

FORM N-2 (Back- Pg. 2 of 4j Certificate Holder's Serial Nos. 7811-01 through CERTIFICATION OF DESIGN Design spedfications certified by E.S. Broczkowski Jr. P.E. State MD Reg. no. 12424 "ien appkable)

DesIgn report* certified by L. VIzi P.E. Prov. Ont. Reg. no. 48244206

  • when 2;nobll]

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this (these) Steam Generator Sub-Assembly (See FiQ. 1) conforms to the rules of construction of the ASME Code,Section III, Division 1.

NPT Certificate of Authorization No. N-2791 Expires January.23, 2004-Date .A" Name Babcock Wicox Canada Signed CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Ontario and employed by Technical Standards and Safety Authority of Ontario. have Inspected these Items described in this Data Report o , and state that to the best of my knowledge and belief, the Crtificate Holder has fabricated these parts or appurtenances in accordance with the ASME Code, Section Ill, Division 1. Each part listed has been authorized for stamping on the date shown above.

By signing this certificate, neitherthe Inspector nor his employer makes any warranty, expressed or Implied, concerning the equipment Iscribed in this Data Report. Furthermore,'neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property mage or loss of any kind aq om r nected with this Inspection.

Date/ " Signed ions ____-,or) S____,,__W.____________________n__________,______,

t mtoftad.~spddpo q (Nan Scl. (ncL enoorerrna,,ts) andsute orprov. andno.]

Attachment to FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES Page S of 4 Cer*tcate Holder's'Serial N.os 7811-01 through "

National Board Nos. 196 through -

1. Manufactured and certified by Babcock &Wilcox Canada,.581 Coronation Boulevard, Cambrddae, Ontario d lari e-- ........
2. Manufactured for SGT Ltd. P.O. Sox 1219. Lusby, Maryland 20657
3. Locaeon of installation CCNPP Units 1&2, Lusby, Maryland 20657.4702
4. Type:

5.ASME Code:

List #1: .

Material Specification Tensile Strength

- -PrimaryHead . SA-508C.3a . go ksi Primary Head Inlet Nozzle SA-508 Cl. 3a go ksl Primary Head Outlet Nozzle SA-508 Cl. 3a *90 ksl Base Support Stool SA-533 Type B Cl. 1 80 ksn Tubesheet SA-508 Cl. 3a So ksi Tubes SB-163 N-20-4 (Alloy 690) 80 ksi Secondary Side Shell Cans SA-508 0l. 3a o0ksi Secondary Side Shell Cone SA-503 Cl. 3a 90 ksl Primary Manway Covers SA-533 Type B Cl. 1 . 80 ksi Secondary Handhole Covers SA-533 Type B Cl. 1 80 kst Secondary Inspection Port Covers SA-533 Type B Cl. 1 80 ksi Small Nozzles - Primary Side SB-166 N06690 69.9 ksi Small Nozzles- Secondary Side SA-350 LF2 70 ksi Blowdown Nozzles SFA 5.5 E7018-Al Buildup 70 ksi Recirculation Nozzle SFA 5.5 E7018-Al Buildup 70 ksi List #2:

Code Cases: N-20-4 N-41'1-1 N-474-1 2142-1 2143-1

"__ _N-_4:0-1 4'-11 I N-416-1 List #3:

Nominal Thickness Min. Design Thickness Inner Diameter Primary Head 7" -7.000" Tubesheet 21.875" 21.500" Secondary Side Shell Cans -.

1) Shell above Tube-sheet 4.375" 4.25"' - 13"3 3116n
2) Remainder of Shell 2.a75" 2.77" .13'-3 3/16" Secondary Shell Cone
1) Above Secondary Shell Can 5.125" 5.000".
2) Conical Portion 4.625" 4.500" Tubes 0.042" 0.038" 0.666" Norm.

Attachrn ntto FORM N.2 CERTIFICATE HOLDERS' DATA REPORT iOR IDENTICAL

Attachment to FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES Page 4 of 4 Cert[ficate Holder's Serial Nos. 7811 -01 through National Board Nos. 196 through

1. Manufactured and certified by Babcock & Wilcox Canada, 581 Coronation Boulevard, Cambridge, Ontarlo iler) 4"ime aM swr.,4a(NPTCM9UftWtS
2. Manufactured for SGT Ltd. P.O.-Box 1219,.Lusby, Maryland 20657,
3. Location of Installation CCNPP Units 1&2, Lusby, Mavalnd. 2O657-4702'
4. Type:

5.ASME Code:

List #4:

Secondar Side Primar Side Design Pressure 1015°sa 2500 psia Desi n Temperature 550°F 650TF Hydrotest Pressure -- 3125 psia Hydrotest Temperature - 70 'F FIGURE 1 GENERAL ARRANGEMENT

JQA-9 9-13 4 ý FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND .APPURTENANCES*

-As Required by the Provisions of the ASME Code, Section lit Not to Exceed One Day's PicodwitIon- - -- pg. iof ... 2 Japan Steel Worlcs, Ltd. ,Hr+/-rcran PLant/4-bat.sU-c'achi, Muroan, Hoklaido,0Sl-8505

1. Manufacwred and certified by Emma andeddress et NPTrConificasa Xaldtrl
2. Manufactured for Elbc G WTi1cox,981 Coronation 11lvd. n~~,1 XCnrdea Vanaf LU riw N WWI 01oflM=1111d,1, Calvert Cliffs Kuclear Poweri Pla'nt unit. 1. - ,2 calvirt.Ccunt3:y;Marylafld
3. Locationi __- Czimawand add?.si _ _

2 91.-SOS. Cl. Se. 2.999

¶L71e 4., N17917Re.

Tvna: - - If SA-508Cl. itn. Osi rero 3 -

Idrawirig uoJ CME'L sped. M.id Itanilla siremach) ICFWI 1you .

A1AO tA. .I4 IlL 2V'.AT 1, 1989 Ngo ddendaI

6. Fabricated Inaccardan~ce with Const. Spec. (Div. 2 onlyl Revision -Data

- I , lydrcstatia'test is rat perforaid in The Japan Steel Work~s, Ltd.

1.

eadng thi~ckness is min. 0.20" from bae.emetal.

- Cladding materials are SPA-5.4, 1.11 Cl.. 30L 16+ Z3fl- an SEr. 304aýIE0L

- P.O. Nol.a CHf3302064 --JSf Job No. - Fi-NB-43OS 1Eeat No. a985159-21-2 JSW 11C. NO.:1 S . Nom.thickness (in.) Min. design -hlaknass rin. "' - Dla.10(frit & . eghvrf~f&i. '~

a. When applcable, Certificate Holders' Data Reaports are attached for each Item of this report:

-pert or Appurtenance National Part or Appurtenance -National Serial Numbar Board No. Saris! Number Board No.

In Numerical Order -in Nurnaricsl Order

() 1046 402 (21 (27)

(31 (26)

(14)

(301 t7)

(32)

(33]

(341 I (15) (3511)mo lr u rT0.

(74)

(37)

(161 -U1 (381 (20)

(101 (411 ____

(22) __ __ __ __ __ __ __ __

(43)

(.231 (43)

(24) (441 (15) 148)1 (471 (48)

(451 IA pal. Temp. GF. Hydra. test pressure. wi pAcbi at tamnp.

10. Deslginpressure

'Supplemental Informitimi In the form of lists, skatchas, or drawings may be ulad'provided (11) #i.@I SK~ x 11. (2)informattctIon intois 2 snd 3 en this Ortilapr IsIncluded an each sheet. (21each sheatth numbared and %henumber of 3ha~ts Isrcotrded at the ftbof this farm.

(121=81 This lorm (E=01O may be obtained fromn the Order Dept.. ASME, 22 Law Drive, Box 2300, Fairfield, NJ!07007-2300.

4.

JOA 1 34 2 FORM N-2 (Back-Pg. 2of- 2 }

Cartificate Holder's Serial Nos. 1046 through CER71FICATION OF DESIGN DesTgn specifications certified by - iwhan lUplI=blOl FP.E.

r State N/A Reg. no, IVA Oeslgn'report' cartifled by * ~ ~~(Whin N/A Applic-,tl[]- . FP.E. State NIL Reg. no. -

CERTIFICATE OF COMPLIANCE We ceify that the statements made In this report are correct and that this (these) Part conforms to the rules of construction of the ASME Code,Section III, Division 1.

NFT Certificate of Authcrization No. N-2725 Expires J01 21 7001

- ~The J7apan Steel Wo-rks, Ltd Date JuTe 25, 1999 Name- Muroran Plant IflPT C=,"fl:al.ecd-(ela\ Signed

+C"(-u I~a

  • nnm"tad<rff
  • ft $.vs)
  • J. TAI1RA" CERTIFItATE OF INSPECTION ...

Ithe undersigned, holding a valid conrmi'ssion Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ZLLLNIO£S and employed by ,H*LS.I. & I. Co.

of M TFOfD. CT. have Inspected these Items described In thrs Dat Report on ,a'. -. Y , and =tae that to the best of my knowledge and belief, the Certificate Holder has fabricated these part4 or appurtenances in accordance with the ASMIS Code,Section III. Divislon 1. Each part Ulsted has been authorized for stamping on the date shown above.

By slgning this certificate. neither the Inspector nor his employer makes any Warranty, expressed or implied, concerning the equipment described In this Data Report. Furthermore, neither the Inspector nor his employer shall be liable in any mariner forany personal Tnlury or property damage or loss of any kind arising from or connected with thl spaction.

Date. ,Z Signed * .'...Commissions i'#L0145A.LS.

a/*r+*lp'cll lNn 84. Ibn'c audorem*rul ad*s taie r oV.; rQo.I

- *- "+A W RAROATA

.1*

~ BWC

/ ~ ~ /7' 4 ~INCOMING INSPECTION AUG 1999

  • ~ ~~ ~ AAPPROVED
  • 1 4.
  • Ag 4

4.-.44.

  • ** '4.

It

  • V

\*. I %L I

l.).

4.-

a 4.4

'7

°.4 5I? '3

  • ° 4 --..

.. t4..  !

  • 4.......

August 15, 2001 The Steam Gene0ra6tfTeam LetterNo. 01-0013-BWC Action.Require&d No A Washington rtoup lfematNonal, Inc. /Dke Engineeing&Servlces, Inc. Company Babcock & Wilcox, Canada 581 Coronation Boulevard' Cambridge, Ontario Canada, NIR 5V3 Attention: Mr. Ganry Astles, Project Manager

Reference:

CCNPP Steam Generator Procurement Purchase Order No. 4621-CCNP-21-9000

Subject:

CCNPP Unit 1 ASME Design Report

Dear Mr. Astles:

CCNPP and SGT have reviewed ASME Diesign ReportNos. 222-781 1-SR-8.1, Rev. I in accordance with the ASME Boiler and Pressure Vesiel Code Section III, NCA-3260, Division 1, and have determined the report rfieets the owner's requirements per Code.

If you have any questions, please contact me at (704) 382-7148 or David Keen (704) 382 0096.

Action Required:

None Respectfully yours, Kevin J. Connell Rep laIekd&ffS f- -iiGiifd*-Eg-ih -gM -ae .

SGT Ltd.

Attachment:

Calculation Cover Sheet for 222-781 1-SR-8.1 Rev. 1 cc w/ attach: B.R. Rudell D.D. Crawford M.S. Sills K. Wolfcale T. L. Konerth i. B. Wheeler D. S. Keen A.M. Wolfe B. Broczkowski M. C. Scott T. Helms (File)

File 13.021.3.

P.O. Box 1219 .Lusby, MD USA 20657 Phone: (416) 495-8102 Fax: (410) 495-8106

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xl Calvert Cliffs Nuclear Power Plant, Inc.' Date: 81112002

1. Owner: -

(name)

Sheet I of 2 1650 Calvert Cliffs Parkway; Lusby, MD 20657

- - (address) - -

Calvert Cliffs Nuclear Power Plant Unit: One

2. Plant:

(name) -

R&R No. SG-1-001b,' ESP No. ES199601526 1650 Calvert Cliffs Parkway; Lusby, MD 20657 (P.O. no ,job no , etc.)

(address) apt. Type Code Symbol Stamp: N/A

3. Work Performed by. - Calvert Cliffs Nuclear Power Plant Di Authorization No.: N/A (name) Exp Date: N/A Section7XI Class: One 1650 Calvert Cliffs Parkway, Lusby, MD 20657 (address)

System Number 064 System Name: Reactor Coolant System

4. Identification of System:

5.(a) Applicable Construction Code and Class: ASME B31.7 1969 Edition, Summer 1971 Add; Class One 1998 Edition (b) Applicable Sect XI Ed. for Repairs/Replacement

6. Identification of Components Repaired or Replaced and Replacement Components: Repaired, ASME Code National Year Replaced, oi 'Stamped Name of Name of Manufacturers Othe Built Replacemen (Yes or No)

Serial Number Board No. Identification Componet Manufacturer

- 4nn T tI...

N/A Reactor Coolant Piping IYV Rtep alre*uaed egC Piping System Combustion 30" & 42" CC-1 N/A Reactor Coolant Piping aced Engineering Piping

7. Description of Work:

the replacement of #11 This plan was for the Reactor Coolant Hot Leg and Cold Leg Pipe welding to support Steam-Generator; -... .. ... . .. .. .. . ......-

PneumaticS] Nominal Operating -Pressure- Inservice:. Leakage': - Functional" E

8. Tests Conducted: Hydrostatic.E-l Pressure: 2273 psi. Test Temperature: 0_2 Deg. F I

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be uSed, provided (i) gize is 8-1/2 in. x- 1 in.,

each sheet is numbered and the (2) information in Items 1 through 6 on this report is included on each sheet, and (3) number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section XI System Leakage Test of the affected component was performed during the system conditions listed in section 8. of this report. Code Case N-416-1 was invoked to satisfy Section XI required pressure-.

tests. Addtional Section III Examinations were performed (as applicable) to satisfy Code Case N-416-1 and Req.Guide 1.147. A Section Xl Surface Examination and Ultrasonic Examination of the affected component was performed to satisfy Section X1 Pre-Service NDE Requirements. With an approved Relief Request from NRC, we were allowed to meet the 1993 Addenda of the 1992 Edition of Section II1. This addenda permits the use of wire type IQO's (Image Quality Indicators) as an alternative to plaque type IQl's for radiographic examinations. Plaque type IQI's are required by Section III, 1992 Edition which is referenced by Code Case N-416-1 and by the installation code which is Section II1i 1989 Edition.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this RepalrlReplacernent conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A

- 00,Charles "-Or ~~#Ž~7 H.Ballard Signed: ~t~j(

  • Engineering Technician Date: 8/1/2002

'Owner oiorhO'eees designee'. Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components described in this Owner's Report during the period 2-(i"-6 ?.. to 6- 28-0)7%. , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor hiý employer makes any warrant, expressed or implied, concirnifig' the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his

-- employer-shall he l1ihlc in any rnnerb._an.personalinjury.or property damage of a loss of any kind arising from or connected with this inspection.

~~~~

~ý Commnissions: /e8ZZt- ,'2 4l Inspector's Signature National Board, State, and Endorsements Date(ý2* , 200 Z..

6'

FORM NIS-2 OWNER'S REPORT FOR REPAIR I REPLACEMENT, ACTIVITY As Required Required by the Provisions of the ASME Code Section X1-

1. Owner: Calvert Cliffs Nuclear Power Plant, Inc. Date: - 8/1/2002 (name).

Sheet I of 3 1650 Calvert Cliffs Parkway; Lusby, MD 20657 (address)

2. Plant: 'Calvert Cliffs Nuclear Power Plant 'Unit: -One (name) 1650 CalvertCliffs Parkway; Lusby, MD 20657 R&F No. SG-1-001c, ESP No. ES199601526 (P.O. no ,job no., etc.)

(address)

Type Code Symbol Stamp: N/A

3. Work Performed by: Calvert Cliffs Nuclear Power Plant Dept._ Authorization No.: N/A (name)

Exp Date: N/A Section XI Class:- Two 1650 Calvert Cliffs Parkway, Lusby, MD 20657, (address)

4. Identification of System: System Number Var. -System Name: Ma in Steam, BID, FMV, Aux/Feed,'& Recir 5.(a) Applicable Construction Code and Class: ASME B31.1.0 1967 Edition, 1972 Add (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition
6. Identification of Components Repaired or Replaced and Replacement Components: ASME Repaired, Code National Other Year Replaced, or Stamped Name of Name of Manufacturers Serial Number Board No. Identification Built 'Replacemen (Ye's or No)

Componet Manufacturer 1975 - Repaired/RepI No Piping System Bechtel DB-1,"EB-1,-5,& 6 N/A Main Steam, Feedwater, - -.

Blowdown, Wet-Layup Recirc. & aced Aux. Feedwater Sys.

ES199601526-118 N/A Elbow, Pipe, 4 in. 90 deg. Long "2001 Replacement No Elbow SGT-Aux.

Feedwater Rad, Sch.80, Btt Wid, SA-234 Gr.

WPB SGT-Wet-Layup ES199601526-111 NIA Valve, 2 in., gate, 800#, ASME 2001 Replacement No valve

'Recirc. SA-105, Mark #19 2001 Replacement No Pipe SGT-Wet-Layup ES199601526-111 N/A Pipe, 2 in. Sch. 80, ASME SA-106 Recirc. Gr.B 2001 Replacement No SGT-Wet-Layup ES199601526-111 N/A Flange, 2 in., 150 lb., Raised Face, Flange Recirc. Sch.40, Socketweld, ASME SA105 2001 Replacement No SGT-Blowdown ES199601526-110 N/A Clamp, Pipe Anchor Base, 2 In.

Pipe Clamp for PG-41 / PG-43 per Drwg.#

Base FSK-MP-0571SH0003 & 0005, Part# 5.

2001 Replacement No SGT-Aux. ES199601526-118 NIA Pipe, 4 In. Sch. 80, Carbon Steel, Pipe Feedwater ASTM A-106 Grade B 2001 Replacement No Pipe SGT-Blowdown ES199601526-110 N/A Pipe, 2 In. Sch. 80, ASTM A-335 Gr. P22 SGT-Blowdown 2001 Replacement No ES199601526-110 N/A Pipe, 2 In. Sch. 80, ASTM A-335 Pipe Gr. P22 SGT-Blowdown 2001 Replacement No Elbow ES199601526-110 N/A Elbow, Pipe, 2 In. 90 deg. 3000 lb.,

Socketweld; ASTM A-182 Gr. F 22 SGT-Blowdown 2001 Replacement No ES199601526-110 N/A Coupling, 2 in., 3000 lb.,

Coupling Socketweld, ASTM A-182, Tp. F22 SGT-Blowdown 2001 Replacement No Angle ES199601526-110 NIA Angle, 4 In.X 4 in. X 114 In.,

ASTM A-36 No SGT-Blowdown ES199601526-110 N/A Nut, Hex. Head, 1/2 In. X 13 TPI, 2001 Replacement Nut SA-194 Gr. 2H

Eye Nut SGT-Blowdown ES199601526-110 N/A Eye Nut, Weldless, 1/2 In., 2001 Replacement .-.

Grinnell, Fig. 290N ES199601526-110 No Plate, C.S. SGT-Blowdowwn N/A Plate, Steel, 1/2 In. X 48 In. X 96 2001 Replacement ES199601526-110 In., ASTM-A36 No Angle SGT-Blowdown N/A Angle, 1 In. X I In. X 1/4 In., 2001 Replacement No ES199601526-110 ATSM A-36 SGT-Blowdown N/A Clamp, Pipe, 2 In., for use on 2001 Replacement No Pipe Clamp ES199601526-1 10 Grinnell Fig. 295N, with Hardware No Spring Can SGT-Blowdown N/A Support, Variable Spring Can, 2001 Replacement ES199601526-110 Grinnell Figure # B-268N, Tp. A, Size 000 No Fitting SGT-Blowdown N/A Lateral, 2 In., 3000 lb., 2001 Replacement ES199601526-1 10 Socketweld, ASTM A-182 Gr. F22 NIA Elbow, Pipe, 2 In. 45 deg. 3000 lb., 2001 Replacement No Elbow SGT-Blowdown ES199601526-11O Socketweld; ASTM A-182 Gr. F 22 No Elbow SGT-Blowdown N/A Elbow, Pipe, 2 In. 90 deg. Long 2001 Replacement Rad, Sch.80, Butt Weld, ASTM A 234 Gr. WP22 ES199601526-110 No Angle SGT-Blowdown N/A Angle, 3 In. X 3 In. X 114 in., 2001 Replacement ASTM A-36 ES199601526-110 No Tube Steel SGT-Blowdown N/A Tube Steel, 3 In. X 3 In. X 1/4 In., 2001 Replacement ASTM A-500 Gr. B ES199601526-109 No Radiographic SGT-Maln Steam N/A Plug, Radiographic, 1 114 In. 2001 Replacement Plug ASTM A675, Gr. 80 ES199601526-109 No Pipe SGT-Feedwater ES199601526-110 N/A Pipe, 16 In. Sch. 80, ASME SA 2001 Replacement 335 Gr. P22 ES199601526-109 No Elbow SGT-Feedwater N/A Elbow, Pipe, 16 In. 90 deg. Long 2001 Replacement Rad, Sch.80, Butt Weld, ASME SA-234 Gr. WP22 ES199601526-110 No Radiographic SGT-Feedwater N/A Plug, Radiographic, 1 1/4 In. 2001 Replacement Plug ASTM A739, Gr. B22 ,

No Concentric SGT-Wet-Layup N/A Reducer, Pipe, Concentric, 3 In. X 2001 Replacement Reducer Recirc. 2 In., Sch. 80 ASTM A-234, Gr.

WPB

7. Description of Work: -.-..

This plan was for the work to be done to the Main Steam, Blowdown, Feedwater, Aux. Feedwater and the Wet-Layup Recirc. lines that are associated with the replacement of #1 1 Steam Generator.

8. Tests Conducted: Hydrostatic:[] PneumaticG] Nominal Operating Pressure: Inservice: ] Leakage: 2 Functional: []

Pressure: 890 psi. Test Temperature: 3.22 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in Items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 3 of 3 FORM NIS-2 (Back)

9. Remarks:

A .qr.inna Yl .qv.*l~r Leakaae Test of the affected component was performed durnn the system conditions listed in section 8. of this report. Code Case N-416-1 was invoked to satisfy Section Xl required pressure tests. Addtional Section III Examinations were performed (as applicable) to satisfy Code Case N-416-1 and of the affected component Req.Guide 1.147. A Section Xl Surface Examination and Ultrasonic Examination was performed to satisfy Section XI Pre-Service NDE Requirements. With an approved Relief Request from NRC, we were allowed to meet the 1993 Addenda of the 1992 Edition of Section II1.This addenda nermits the use of wire type IQI's (Image Quality Indicators) as an alternative to Plaque type IQI's for ra-diographic examinations. Plaque type IQ's are required by Section III, 1992 Edition which is referenced by Code Case N-416-1 and by the installation code which is Section I1l, 1989 Edition.

Applicable Manufacturer's Data Reports to be Attached

" Certificate of Compliance Repair/Replacement conforrns to the We certify that the statements made in this report are correct and that this rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H. Ballard Signed: /ýý-,&-'/Engineering Technician Date: 8/1/2002 I

¢L. Owner or Owner's Drsignee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components described in this Owner's Report during the period 'Z-//- 0 Z to Gz- Z's -1=- , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his or employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from connected with this inspection.

200Z.. Commissions: IJ1 &6 2-.26- G?A1lJ-" ,v1".D '/"7/

5*( National Board, State, and Endorsements nfsp ctor's Signature Date'(*z*f Datedf,4y. 2002.=

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section XI

1. Owner: Calvert Cliffs Nuclear Power'Plant, Inc.- Date:--'- 81112002 (name) 1650 Calvert Cliffs Parkway; -Lusby, MD 20657 S- - Sheet I of 3.

(address)

2. Plant: Calvert Cliffs Nuclear Power Plant Unit: - One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. SG-1-001d, ESP No. ES199601526 (address) (P.O no ,job no., etc) 3 .Work Performd by: Cliffs Nuclear Power Plant Dept.

Calvert(Authorization Type Code Symbol Stamp: N/A No.: N/A (name) "Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 SectionXI Class: One (address)

4. Identification of System: System Number 064 System Name: Reactor Coolant Systrm...

5.(a) Applicable Construction Code and Class: ASME B31.7 1969 Edition, Summer 1971 Add;Class One (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition 6 Identification of Components Repaired or Replaced and Replacemeht Components: S....ASME Repaired, Code Name of "Nameof, Manufacturers ,National Other "Year R"eplaced, oi Stamped Componet Manufacturer Serial Number Board No. Identificktionf Built Replacemen (Yes or No)

Piping System Bechtel 1" & under CC-9 N/A Reactor Cooling Sys. 1970 Repaired/Repl No Instrumentation aced ES199601526-112 N/A Tubing, 314 In. X .065 Wall, 2001 Replacementt No, Tubing SGT-Reactor Coolant Flow ASME SA 213, Tp. 316 Indication ES199601526-112 N/A Clamp, Tube, 3/4 In., 2 2001 Replacement No 2D Tubing SGT-Reactor Clamp Coolant Flow Directional, Mark#400, Girard Indication P/N 3/4T-SS-2D, A/SA 276 or 479, Tp. 304/316 SGT-Reactor ES199601526-112 N/A Union, Tubing, 3/4 In. Swagelok, 2001 Replacement No Tubing Union Coolant Flow P/N SS-12-TSV-6, ASTM/ASME Indication A/SA182 or A/SA479, Tp. 316 ES199601526-112 N/A Pipe, lin. Sch 80, ASME SA-376, 2001 Replacement No Pipe SGT-Reactor Coolant Flow TP-316 Indication ES199601526-112 NIA Fitting, 1 In. X 314 in. Pipe/Tubing 2001 Replacement No Fitting SGT-Reactor Coolant Flow Connector, Parker, PIN 12-1-ANV Indication

7. Description of Work:

This plan was for the Reactor Coolant System Instrumentation Piping/Tubing and supports, one inch and under, work to support the replacement of #11 Steam Generator.

8. Tests Conducted: Hydrostatic [] Pneumatic-] Nominal Operating Pressure- Inservice: ] Leakage: ] Functional: L]

Pressure: N/_A psi. Test Temperature: N/A Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet Lof t;,

FORM NIS-2 (Back)

.9. Remarks:

No Section X1 Pre-Service NDE was performed in support of this activity.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct aid that this RepalrlReplacement conforms to the rules of the ASME Code,Section XI.

Type Code Syinbol Stamp. N-/A Certificate of Authorization No.: N/A ExpirationDate: N/A S/.Charles H. Ballard Signed: On o/,ie./, Desnee,., Engineering Technician Date: 8/1/2002 SOwner or-Owner's De~igee, Tit*e IV "

Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components described in this Owner's Report during the period Z..-/f-Cl to &,- Z8 0?. -and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the, Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damag6 of a loss of any kind arising from or connected with this inspection.

nsp-t-sgnCotmmissions: d NAto 77 AAJ Z t re, E deeI Inspect r's Signature National Board, State', and Endorsements Da20-a/

FORM NIS-2 OWNER'S REPORT FOR REPAIR I REPLACEMENT ACTIVITY As Required Required by the'Provisions of the ASME Code Section Xl

1. Owner: Calvert Cliffs Nuclear Power Plant, Inc. Date: 8/1/2002 "

(name) 1650 Calvert Cliffs Parkway; Lusby, MD' 20657 Sheet 1 of,"

(address)

Calvert Cliffs Nuclear Power Plant Unit: One

2. Plant:

(name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. SG-1-001e, ESP No. ES199601526 (address) -- (P.O. no.job no., etc)

3. Work Performed by: Calvert Cliffs Nuclear Power Plant Dept. Type Code Syr*bol Stamp: N/A Authorization No.: N/A (name)- Exp Date: N/A 1650 Calvert'Cliffs Parkway,- Lusby, MD 20657 - Section XI Class: One & Two (address)
4. Identification 6f System- SystemNumber -64/83 System Name: Steam Generator Replacement 5.(a) Applicable Construction Code and Class: A1SC, Manual of Steel Construction, 6th Ed..1963 (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition
6. Identification of Components Repaired or Replaced and Replacement Coffiponents: ASME Repaired, Code

,-_ Other Year -Replaced, oi Stamped rame of -Namne of Manufacturers National Serial Number Board No. Identification Built, Replacemen (Yes or No)

Ci omponet ' Manufacturer Cc

'N Cotr N/A #11 Steam Generator Snubber 1970 Repaired/Repl No Combustion N/A Conrip. Support and Sliding Base 'aced Engineering N/A Plate, Steel 1/4 In. ASME SA-36 2001 Replacement No Plate SGT-Steam ES199601526-107

-Generator Supports 2001 Replacement No ES199601526-107 N/A Stud, 2 1/4 In. X 14 in. X 4 1/2 Stud SGT-Steam TPI, ASTM A-193, Gr. B7 Generator Supports 2001 Replacement No ES199601526-107 N/A Nut, Heavy Hex, 2 114 in. X 4 1/2 Nut SGT-Steam TPI, ASTM A-194 Gr. 7

-.... Generator Supports 2001 Replacement No ES199601526-107 N/A Washer, 2 1/4 In., Circular Nut SGT-Steam Hardened, ASME SA-193 Gr. B7 Generator Supports 2001 Replacement No ES199601526-107 N/A Plate, 1/2 In., ASTM B-22, Tp. E Plate SGT-Steam Generator Supports 2001 Replacement No ES199601526-107 N/A Plate, Shim, AISI 4140, 125 RIMS Plate SGT-Steam Finish, Heat-Treat to RC-40 Generator Supports 2001 Replacement No ES199601526-107 N/A Capserew, 1/2 in. X 13 TPI, UNC Capscrew SGT-Steam 3A, Socket-Head, Countersunk Generator Supports per ASTM F-835

7. Description of Work:

This plan was for the work on the Sliding base and the brackets that hold #11 Steam Generator in place.

Pneumatic-] Nominal Operating Pressure: Inservice: ] Leakage. [] Functional: ]

8. Tests Conducted: Hydrostatic []

N.A psi. Test Temperature: N/.AŽ Deg. F Pressure:

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet A.of L FORM NIS-2 (Back)

.9. Remarks:

A Section Xl VT-3 Visual Examination of the affected component support was performed prior to the system" being returned to service. - ,

- Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this Repair/Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H. Ballard Signed: Engineering Technician Date: 8/1/2002 Owner or Owner's Designee, Tte Certificate of Inservice Inspection I, the undersigned, holding a'valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components described in this Owner's Report during the period Z-/1-O . to 6-Zd- r" . , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any, warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

-Commissions: AJS - Z ZCA i.4~ A-7. e InspectorSignature National Board, State, and Endorsements Dat~eýqjkt 82001.

ACTIVITY

-FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT As Required Requied by the Provisions of the ASME Code Section XI

1. On ,r:Calvert Cliffs Nuclear Power Plant, Inc.'! .Date: 81112002 '

811/2002

1. Owner:

(name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657... Sheet I of 2

"(address) ...

Calvert Cliffs Nuclear Power Plant unit: one

2. Plant:

(name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. SG-1-002a, ESP No. ES199601526

-2 . (address) - (P.O. no.,job no., etc.).

Dept. Type Code Symbol Stamhp: N/A

3. WorkPerformedby: -Calvert Cliffs Nuclear Power Plant Authorization No.: N/A Exp Date: N/A 1650-Calvert Cliffs Parkway, Lusby, MD 20657 - Section XI Class: One & Two (address)

SystemNumber 64183 SystemName: Steam Generator Replacement

4. Identification of System:

Class 5.(a) Applicable Construction Code and Class: ASME B&PV Code Sect. III, 1965 Edition, Winter 1967 Add;

-C-Cases: 1332,332-4, 1359-f 1 .-

1998 Edition (b) Applicable Sect XI Ed. for Repairs/Replacement

6. Identification of Components Repaired or Replaced and Replacement Components: ASME Code Repaired,'

Other Year Replaced, oi Stamped Name of Name of Manufacturers National - Built -Replacemen (Yes or No)

Board No. Identification --

Componet Manufactire Serial Number IWIIp IPnflirPEIfI{flI res 20923 #12 Steam Generator I10M R alen-red/Rurn ves Pressure Vessel Combustion CE 67505 2 needm

.Engineering 197 Steam Generator Lower 2001 ' Replacement *. Yes Babcock &

4621CCNP-21-9000 Steam SN: 7811-02 Assembly, Primary Side Head, Generator Wilcock Canada - Tubes and Secondary Shell up to Transition

7. ýDescription of Work:-,

side shell up to the This plan was for the replacement of the primary'side head, tubes, and secondary, of the Feed Nozzle and transition area-of #12 Steam Generator. This also documents the reconfiguration Surface Blowdown Nozzle.

Inservice: El Leakage: 2 Functional. El

8. Tests Conducted: Hydrostatic:E- PneumaticS[ Nominal Operating Pressure:

532" -Deg.F

'Pressure: 890 psi. Test Temperature:

(1) size is 8-1/2 in. x,11 in.,

NOTE: -Supplemental sheets in form of lists, sketches, or drawings may be used, provided sli-et is numbered and the (2) information in Items 1 through 6 on this report is included on each sheet, and (3)-ch number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back),

9. Remarks:

A Section Xl VT-1 Visual Examination of the replacement threaded fasteners was performed to satisfy Section X1 Pre-Service NDE Requirements. A Section Xl System Leakaqe-Test of the affected component was performed durinq the system conditions listed in section 8. of this report. Code Case N-416-1 was invoked to satisfy Section XI required pressure tests. Addtional Section III Examinations were performed (as applicable) to satisfy Code Case N-416-1 and Reg.Guide 1.147. A Section Xl Surface Examination, Eddy Current Examination and Ultrasonic Examination of the affected component was performed to satisfy Section Xl Pre-Service NDE Requirements. With an approved Relief Request from NRC, we were allowed to meet "

the 1993 Addenda of the 1992 Edition of Section III. This addenda permits the use of wire type IQO's (Image Quality Indicators) as an alternative to plaque type IQI's for radiographic examinations. Plaque type IQI's are.

required by Section III, 1992 Edition which is referenced by Code Case N-416-1 and by the installation code which isSection III, 1989 Edition.

Applicable Manufacturer's Data Reports to be Attached "Certificateof Compliance R We certify that the statements made in this report are correct and that this RepairlReplacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A

  • __.. 7 , 6 Charles H. Ballard Signed: Engineering Technician Date: 8/1/2002 Owner or Owner's ferignee, Titte Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have 'nspected the components described in this Owrner's Report during the period Z.-//- d 2 to '7'- / 1- 0 Z.. , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirerients of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermiore, neither the Inspector nor his employer shall be liable in any manner for afiy personal injury or property damage of a loss of any kind arising from or connected with this inspection.

Commissions: 4 AJIe.IX~ /"Z

,* 74 InspcdLs Signature National Board, State, and Endorsements DatLe'.. 99,f 200 -0

('

FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*

As Required by the Provisions of the ASME Code,Section III Not to Exceed One Day's Production Pn. 1 ni dl Pei I of 4

1. Manufactured and certified by Babcock & Wilcox Canada, 581 Coronation Boulevard.I Cambridge.I Ontario NIR 5V3 (name and address of NPT Cartifate Holder)
2. Manufactured for SGT Ltd. P.O. Box 1219, Lusby, Maryland 20657 (name and adresas of Purchaser)
3. Location of Installation Calvert Cliffs Nuclear Powver Plant (CCNPP) Units 1 &2, Lusby, Maryland 20657-4702 (name and address)
4. Type! 7811 E001 Rev. 6 - See attached List #1*- See LIst #1 ....... -........ 2001..

(draw- g no) (marl sper. no.) (tenlme strength) . (CRN) (year buft)

5. ASME Code, Section Ill, Division 1: 1989 No Addenda 1 See attached [ist#2 I (edftmon) - (aIddenda , ate) (cass) . (Code Case no.)
6. Fabricated In accordance with Const. Spec. (Div. 2 only) - Revision - - Date
7. Remarks: Secondary side hydrotest has not been performed. Post-hydrotest final NDE hias'not been perforrhed on secondary side. Previous N-2 form for primary head (National Board No. 403) attached.
8. Noam. thickness (in.) See List #3 Min. design thickness (in.) See List #3 DIa. ID(ft &In.) See List #3 Length overall (ft &In.) -39'-8 7/16" 9 When apolicable. Certificate Holders' Data Recorts are attached foreach item of this reoort Nardonal National or Appurtenance PartSeial Seril Number NuberBoard
  • In Numerical No.Order Part orAppurtenance Board No.

Serial Number in Numerical Order (1) 7811-02 197" (26)

(2) (27)

(3) (28)

(4) (29)

(30) ...

(6) (31)

(7) (32)

(33) ___ __ _ _

(9) _______________

(34)

(10) ____________ _

(35)

(11) __________________

(36)

(12) (37)

(13) (38)

(14) (39)

(15) _ _ _ _ _ _ _ _ _ (40)

(18) ____________ _ (41)

(17) (42)

(18) (43)

(44)

(20) (45)

(21) (46)

(22) (47)

(23) (48)

(24) (49)

(25) (50)

10. Design pressure See List #4 psI. Temp. See List #4 °F, Hydro. test pressure See List #4 at temp. °F (when applicable)

"FORM N-2 (Back- Pg. 2 of.)

Certificate Holder's Serial NoS. 7811-02 through

- CERTIFICATION OF DESIGN Design speclfications certified by E.S. Broczkowski Jr. P.F_ State MD _'Reg. no. 12424

-tMena~ppkeabe)

Deslgn report. certified by L Vzi P.E. Prov. Ont Reg. no. 48244208

- - bthenap~kabe). - - . .. ... .

- C(1ERTIFICATE OF COMPLIANCE We certify that the statements made In this report are correct and that this (these) Steam Generator Sub-Assembly (See Fig. 1) conforms to the rules of construction of the ASME Code, Section ill, Divsiron 1.

NPT Certificate of Authorization No.. N-2791, Expires Januar y23, 2004 Date &iLZ9AI Name Babcock &Wilcox Canada - Signed

'4 NT Ce"Ctle~ .J14arn&'JUR CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or ProvInce of Ontario and employed by Technical Standards and Safety Authority of Ontario have Inspected these items described In this Data Report on4 , and state that to the best of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances in accordance with the ASME Code,Section III, Divislo-n 1. Each part listed has been authorized for stamping on the date shown above.

By slgnirng this certificate, neither the inspector nor his employer makes any warranty, expressed or Implied; conceming the equipment described in this Data Report.- Furthermorea neither the Inspectornorhis employershall be liable In any mannerforany personal Injury or property damage or loss of any kind arising from or connected with this Inspection.

Date S"gd$eLig " Commissions)- ialn

.1 (Auftftedrser LNarLB.Jndtenoomrneant.s) andstate 0: ploY,andno4

Attachment to FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES Page 3 of 4 Certificate Holders Serlal Nos. 7811-02 through National Board Nos. 197 - through -

1. Manufactured and certified by Babcock &Wilcox Canada, 581 Coronatio-nBoulevard, Cambrld-goe Ontario
2. Manufactured for SGT Ltd. P.O. Box 1219, Lusby, Ma1ryland 20657. -,:" .
3. Location of Instalation CCNPP Units 1&2, Lusby, Maryland 20657-4702 ..
4. Type:

5ASME Code:

List #1:

. . . Material Specification - Tensile Strength Primary Head SA-508 CI. 3a so ksi PdmaryHead Inlet Nozzle .. SA-508 Ci. 3a . . . . 90 ksi Primary Head Outlet Nozzle SA-508 CL 3a 90 ksi Base Support Stool SA-533 Type B Cl. 1 80 ksl Tubesheet SA-508 Cl. 3a 90 ksl Tubes SB-163 N (Alloy 690) 80 ksl Secondary Side Shell Cans SA-508 Cl. 3a 90 ksi Secondary Side Shell Cone SA-508 Cl. 3a ,- 90 ksi Primary Manway Covers SA-533 Type B CI. 1 80 ksi Secondary Handhole Covers SA-533 Type B Cl. 1 -80 ksi

-Secondary-Inspection Port Covers.. - SA-533 Type B C1___-80 ksi .-..

Small Nozzles - Pdmary Side SB-166 N06690 69.9 ksl Small Nozzles- Secondary Side SA-350 LF2 70 ksi Blowdown Nozzles SFA 5.5 E7018-Al Buildup 70 ksi Recirculation Nozzle SFA 5.5 E7018-AI Buildup 70 ksl List #2:

Code Cases: N-20-4 N-71-15 N-41 1-1 N-474-1 2142-1 2143-1 N-401-1

________"N-416-1 List #3:

Primary Head 7" 7.000" Tubesheet 21.875" 21.500" _

Secondary Side Shell Cans

1) Shell above Tubesheet 4.375" . 4.25" 13'-3 3/16"
2) Remainder of Shell 2.875" - 2.77" - - - 13'-3 3/16" Secondary Shell Cone
1) Above Secondary Shell Can 5.125" 5.000"
2) Conical Portion 4.625" 4.500" Tubes 0.042" 0.038" - . . 0.666" Nom.

Attachment to FORM -2 CERTIFZ TE HOLDERS DATA REPORT FOR IDENTICAL

1 NUCLEAR PARTS AND APPURTENANCES Certificate Holder's Serial Nos. 7811-02 Page4of4 through.

National Board Nos. 197 through -

1. Manufactured and certified by Babcock & Wilcox Canada, 581 CoroatILon Boulevard, Cambridge, Ontario
2. Manufactured for SGT Ltd. P.O. Box 1219, Lusby, Maryland 20657
3. Location of Installation - CCNPP Units 1&2, Lusy. Maryland',* 2067470'2
4. Type:

N SASME Code:

LUst #4:

Secondary Side Primary Side Desin Pressure ... 1015 sla 2500 a Design Temperature 550"F; 6509F Hydrotest Pressure - - 3125 psia Hydrotest Temperature - 70i'F FIGURE 1 GENERAL ARRANGEMENT ..r;

JQA-9 9-16 1 a2-FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*

As Required by thte Provisions of the ASME Code, Section [if

___-__Not to Exceed One Day's Production -Pg. Iof- 2

1. Manufactured and certified by The Japan Steel Works, Ltd. Muroran Plant/4-Chatsu-machi, Muroran, Hokkaido, 051-8so 5 Imam*. Weraddoress of NPT Csrrtdcr1=a I1oIder ,7aoa,,
2. Maj'ulactured for S1CrnioBvd, Cambridge, Ontario, I5V Coda
3. Lorationotinstallatlon* Calvert, Cliffs Nuclear Pow~er Plant Unit I ry 2 ddrettUIA Calvprt Contrmy, M;R t

[amevW

-4. Type; 11147951ff, lýeV. 2 -SA-SOS8, Cl. 3a -Min. S0ksi ls fdeawrg no.) . (zmatl. Spec.nl - floie tde t S~a tfWthl ic~N1 (year bIRF S SICoeSetoIlivso1: 1989 No addenda I1

5. SMSCod.

II.Divalo Sctin 1:* dde~adate) (081:.) Icade case RajI G. Fabricated in accordance with Conat. Spec. jDIv. I. only) 0-. Revision - Data 7 ~Aernae.! IfYdrostzkUic test is not performed in The Japan Steel Works, Ltd. _

Cladding .thickness is mint. 0.2011 from base metal.

Cladding materials are SFA-5.4, AWS Cl. E3OSL-l6 + E308L-16 and SFA-5.9 ER309L +* E)R30BL.

P.O. No. :C153302064 JSW Job No.. :FRE-4305 treat No. -:9SW61-1-1 JSI4 PC. -No.

83.Nom. thic~tness (in.- 7-1/4" Mint. design thick~is s fin.) 7-W" .. OLID.(ft&in.1) 5 '470..1!. Length overill If%& in.) S-ieZ.72"j S. When applicable, Certificate H~olders' Data Reports are attached for each Item of %W1s report:

Partor Appurtenance National Part or'Appurtoenace 14alional Social Numbir Board No.' Serile Number Board No.

In Numerical Order* In Numericalt Order 1047 403 (281 (2) (27)_

(3) (28) 14) i5)

(6) (311 (7) 132) 133)

(34)

(101 (35) till (35)

(371 (38)

(391 (401)v (14) (41) NUVIN ~8 (42) rn 4n (19) (44) 1201 145)__ __ Q.G. 16 (221) (471- __________ A (48) 1241 (49)

(251 (501

10. Design pressure - /IA - psi Temp. VA OF. H.ydra. test pressure N/&A ittemp. *F wSuppleinental informaiotti n the fonm of lists. skatchas. ot drewtings may be used provided III stza Is SY xA 11I.121ftnlornrecon hr Items 2 and 2 on this Oars 114P~rt Is Imcludue en each sheet. (3)acccl sheet is numbered end ml. numbe of aheats Isrecardedatithe top of this form.

112/81 Thli form tE200040) marybe obtalned from thle Wree Oept:. ASME, 22 Law Ctive. Box 2300. FaIrfield. NJ 07007-2300.

JQA-99-16 i FORM N-2 (Back - Pg.2 of2__.},

Certificate Holder's Serial Nos. 07 through CERTIFICATION OF DESIGN Design specifIcailons certified by _N/A 4whin appacaea~la "P.S. Scale /A. Reg. no. /

Design report certified by." " F/eg. no. X/A P.E. State NIA, (Whi'n lpplkawal CERTIFICATS OF COMPLIANCE "We certify that the statements made In thisreport are corrc and that thi (these) Yart conforms to the rules of construction of the ASME Code, Section Ill, Divisk NPT Certificate of Authorization No 1(-2725 Expires CECJ1E I21,N2001N - -

The Japan Steel Works, Ltd Data ZuIT 28, 1999 Muroran Plant Namea. (

IN PrCa rd hc lt :x et e I - 7*Sg n e o

(\ uthedzd 'SW*stItvtI CERTIFICATE OF INSPECTION.

1, the undersIgned, holding a vaflid commission Issued by the National Board of Boifer and Pressure Vessel inspectors and the State or Province of ILLINOIS - and employed by ----. S-... a .Co.

  • of H'.FOD CT. have Inspected these Items described In thi Data Report a and state tha tothe best of myknowledge and bellef, the CerritIcEae Holder has fabricated these parts or aPPurtenances/n accordaAce wfti th'e ASMwCoh,Section III, Division 1. Each part listed has been authorlzedc for stamping on the date shown above.

By signing this certificate, neithir the lnspecto'r nor his employer makes any warranty, expressed or Implied, concerning the equipment described In this Data Report. Furthermore, neither the Inspectot nor his employer shadlb a liable In any manner for any personal injury or propery damage or loss of any kind arising from or'connected with this inspectlon.

DaZL gne !2 - "-=I Commissions Na # 10104 N, B'_ A

/ .nrnz4g H. KISHIDA KISHIDA 5Z9SC!OSJ It~%ad-)

94, liic. fioACM6"t' amtd Xtatt w3PCOY.

W~4M041 "A" /./,44 "

16' - ..

7/:

BWc INCOMING INSPECTION SEP S-1999 QC. 16

  • APPROVED

,)IIEWED AUG-.1 20M

-set 14 1*5y

2

. i

.1

FORM NIS-2 OWNER'S REPORT FOR REPAIR I REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section XI

1. Owner: -,Calvert Cliffs Nuclear Power Plant, Inc. Date::- 81112002

"(name)'

1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheetlof 2

((address)

2. Plant: . 'Calvert Cliffs Nuclear Power Plant rUnit: One' I .. I (name) 1650 Calvert Cliffs Parkway; Lusby, MD '20657- SR&R No. SG-1-002b, ESR No. ES199601526 (address) (P.O. no ,job no., etc.)
3. WorkPerformedby: -Calvert 3b(name) Cliffs Nuclear Power Plant Dept. TyeCode Symbol

. Auth6rizati6n N6.: N/A. .

Exp Date: N/A "

iRA C0alv.ert Cliffs Parkway. Lusbv. MD 20657 Section XI Class: Ore' (address)

4. IdentificationofSystem: SystemNumber 064 System Name: Reactor Coolant System.

5.(a) Applicable Construction Code and Class: ASME B31.7 1969 Edition, Summer 1971 Add; Class One 1998 Edition (b) Applicable Sect XI Ed. for Repairs/Replacement

6. Identification of Components Repaired or Replaced and Replacement Components: ASME Repaired, Code Name of Manufacturers 'National Other Year Replaced, oi -Staa*id

'Name of Manufacturer Serial Number Board No. Identification Built Replacemen (Yes or No)

Componet 1970 Repaired/Repi Yes Piping System Combustion 30" & 42" CC-1 N/A , Reactor Coolant Piping 1970 -1 Repaired/Rept Yes' Piping seed Engineering

7. Description of Work:

This plan was for the Reactor Coolant Hot Leg and Cold Leg Pipe 'welding to supp6rt the replacement of #12 Steam Generator.'

8. Tests Conducted: Hydrostatic:f-l Pneumatic] Nominal Operating Pressure. Inservice. EL Leakage: ] Functional E]

Pressure: 2273. psi. Test Temperature: L3.2 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size is 8-1/2 in. x 1I in.,

(2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

I-Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

A Section XI System Leakage Test of the affected component was performed dudnq the system conditions listed in section 8. of this report. Code Case N-416-1 was invoked to satisfy Section X1 required pressure tests. Addtional Section III Examinations were performed (as applicable) to satisfy Code Case N-416-1 and Rea.Guide 1.147. A Section Xl Surface Examination and Ultrasohic Examination of the affected component was performed to satisfy Section Xl Pre-Service NDE Requirements. With an approved Relief Request from NRC, we were allowed to meet the 1993 Addenda of the 1992 Edition of Section II1. This addenda permits the use of wire type IQO's (Image Quality Indicators) as an alternative to plaque type IQI's for radiographic examinations. Plaque type IQI's are required by Section III, 1992 Edition which is referenced by Code Case N-416-1 and by the installation code which is Section 111,.1989 Edition.

Applicable Manufacturer's Data Reports to be Attached "Certificateof Compliance We certi* that the statements nmade-in this report are correct and that this Reoair/ReoIacemnent conforms to the rules of the ASM-E Code,Section XI.

Type Code Symbol Stamp: N/A N

Certificate of Authorization No.: N/A Expiration Date: N/A Charles Hl. Ballard Signed: ,_Engineering Technician Date: 8/1/2002 Owner or Owner's gnee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components described in this Owner's Report during the period Z-//-O Z to 6 - Z8-0 Z?., and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures descibed in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer inakes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspect6r i6dt hbi' employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

AfrpK,/ LI or,s~i6nure - "NtCommissions:iol oaj, ,,knor National Board, Statefand Endorsements Ap-e or's Signature Date 200 20

FORM NIS-2 OWNER'S REPORT FOR REPAIR I REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xl

1. Owner: Calvert CliffsNuclear Power Plant, Inc. Date: 8/2/2002 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet 1 of 3
2. Plant: Calvert Cliffs Nuclear Power Plant Unit: -One (name) 1650 Calvert Cliffs Parkway; Lusby, MD '20657 R&R No. SG-1-002c, 'ESP No. ES199601526 (address) (P.O. no., job no., etc.)

I 1 1 ,, I ,Type Code Symbol Stamp: N/A

3. Work Performed by: Calvert Cliffs'Nuce'ar Power Plant Dept. Authorization No.: N/A (name) I Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class: Two (address)
4. Identification of System: System Number Var.'*- SystemName: Main Stearmi, B/D, FIW, Aux/Feed, & Recir 5.(a) Applicable Construction Code and Class: ASMME B31.1.0 1967 Edition, 1972 Add (b) Applicable Sect XI Ed. for Repairs/Replacement .. 1998 Editionh
6. Identification of Compbnents Repaired or Replaced and Replacemeint Components: ASME Repaired, Code Name of Name of Manufacturers National Other Year Replaced, oi Stamped Componet Manufacturer Serial Number Board No. Identification Built Replacemen (Yes or No)

Bechtel DB13, EB-I,-5,& -6 N/A Main Steam, Feedwater, 1975 Repaired/Rep] -No Piping System -

Blowdown, Wet-Layup Recire. & aced Aux. Feedwater Sys.

Elbow SGT-Aux. ES199601526-118 N/A Elbow, Pipe, 4 in. 90 deg. Long 2001 Replicement No Feedwater 1Rad, Sch.80, Btt Wld, SA-234 Gr.

WPB valve . SGT-Wet-Layup ES199601526411 N/A Valve, 2 In., gate, 800#, ASME 2001 Replacement No Reclrc. SA-105, Mark#19 -_

-Pipe SGT-Wet-Layup ES199601526-I1l N/A *Pipe, 2In. Sch. 80, ASMESA-106 ,2001 Replacement, No Recirc. Gr.B_,

SGT-Wet-Layup ES199601526-111 N/A Flange, 2 In., 150 lb., Raised Face, 200f Replacement No Flange Recirc. Sch.40, Socketweld, ASME SA105 SGT-Blowdown ES199601526-110 N/A Clamp, Pipe Anchor Base, 2 In. 2001 Replacement No Pipe Clamp Base for PG-41 / PG-43 per Drwg.#

FSK-MP-0571SH0003 & 0005, Part# 5.

Pipe SGT-Aux. ES199601526-118 N/A Pipe, 4 In. Sch. 80, Carbon Steel, 2001 Replacement No Feedwater ASTM A-106 Grade B Pipe SGT-Blowdown ES199601526-110 N/A Pipe, 2 In. Sch. 80, ASTM A-335 2001 Replacement No Gr. P22 Pipe SGT-Blowdown ES199601526-110 NIA Pipe, 2 In. Sch. 80, ASTM A-335 2001 Replacement No Gr. P22 Elbow SGT-Blowdown ES199601526-110 N/A Elbow, Pipe, 2 In. 90 deg. 3000 lb., 2001 Replacement No Socketweld; ASTM A-182 Gr. F 22 Coupling SGT-Blowdown ES199601526-110 N/A Coupling, 2 In., 3000 lb., 2001 Replacement No Socketweld, ASTM A-182, Tp. F22 Angle SGT-Blowdown ES199601526-110 N/A Angle, 4 In. X 4 In. X 114 In., 2001 Replacement No ASTM A-36 SGT-Blowdown ES199601526-110 N/A Nut, Hex. Head, 112 In. X 13 TPI, 2001 Replacement No Nut C2A InA 9--* -1W

Eye Nut SGT-Blowdown ES199601526-110 N/A Eye Nut, Weldless, 1/2 In., 2001 Replacement No Grinnell, Fig. 290N SGT-Blowdown ES199601526-110 N/A Plate, Steel, 1/2 In. X 48 In. X 96 2001 Replacement No Plate, C.S.

In., ASTM-A36 SGT-Blowdown ES199601526-110 N/A Angle, 1 In. X I In. X 114 In., 2001 Replacement No Angle ATSM A-36 SGT-Blowdown ES199601526-110 N/A"-- Clamp, Pipe, 2 In., for use on 2001 Replacement" No Pipe Clamp Grinnell Fig. 295N, with Hardware Spring Can SGT-Blowdown ES199601526-110 N/A Support, Variable Spring Can, 2001 Replacement No Grinnell Figure # B-268N, Tp. A, Size 000 SGT-Blowdown ES199601526-110 N/A Lateral, 2 In., 3000 lb., 2001 Replacement No Fitting Socketweld, ASTM A-182 Gr. F22 SGT-Blowdown "ES199601526-110 N/A Elbow, Pipe, 2 In. 45 deg. 3000 lb., 2001 Replacement No Elbow Socketweld; ASTM A-182 Gr. F 22 SGT-Blowdown ES 199601526-110 N/A Elbow, Pipe, 2 In. 90 deg. Long 2001 Replacement, No Elbow Rad, Sch.80, Butt Weld, ASTM A 234 Gr. WP22 SGT-Blowdown ES199601526-110 NIA Angle, 3 In. X 3 In. X 1/4 In, 2001 Replacement No Angle

-' ASTMA.-36 SGT-Blowdown "ES199601526-110 N/A Tube Steel, 3 In. X 3 In. X 1/4 In., 2001 Replacement No Tube Steel ASTM A-500 Gr. B SGT-Main Steam' ES199601526-108 N/A Plug, Radlogral'hic, 11/4 In. 2001 Replacement,, No Radiographic Plug ASTM A675, Gr. 80 Pipe, SGT-Feedwater ES199601526-109 N/A Pipe, 16 in. Sch. 80, ASME SA 2001 Replacement No 335 Gr. P22 - 1 SGT-Feedwater ES199601526-109 NIA Elbow, Pipe, 16 In. 90 deg. Long 2001 Replacement No Elbow Rad, Sch.80i Butt Weld, ASME SA-234 GC.WP22 SGT-Feedwater, ES199601526-109 N/A Plug, Radiographic, 11/4 In. 2001 Replacement No Radiographic Plug ASTM A739, Gr. B22 SGT-Wet-Layup ES199601526-111 NIA Reducer, Pipe, Concentric, 3 In. X 2001 Replacement No Concentric Reducer Recire. 2 In., Sch. 80 ASTM A-234, Gr.

WPB 7: Description ofWork:

This plan was for the work to be done to the Main Steam, Blowdown, Feedwater, Aux. Feedwater and the Wet-Layup Recirc. lines that were associated with the replacement of #12 Steam Generator.

8. Tests Conducted: Hydrostatic ,lPneumaticdj Nominal Operating Pressure: Inservice:EL Leakage.2- Functional:EL-]

Pressure: 890 "psi. Test Temperature: Q_2 Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in Items 1through 6 on this re15ort is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 3 of 3 FORM NIS-2 (Back)

9. Remarks:

A Section Xl System Leakage Test of the affected component was performed during the system conditions listed in section 8. of this report. Code Case N-416-1 was invoked to satisfy Section XI required pressure tests. Addtional Section III Examinations were performed (as applicable) to satisfy Code Case N-416-1 and Req.Guide 1.147. A Section X1 Surface Examination and Ultrasonic Examination of the affected component was performed to satisfy Section X1 Pre-Service NDE Requirements. With an approved Relief Request from NRC, we were allowed to meet the 1993 Addenda of the 1992 Edition of Section Ill. This addenda permits the use of wire type IQI's (lmage Quality Indicators) as an alternative to plaque type IQI's for radiographic examinations. Plaque type IQO's are required by Section III, 1992 Edition which is referenced by Code Case N-416-1 and by the installation code which isSection III, 1989 Edition.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that tUis Repair/Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H.Ballard Signed: , Engineering Technician Date: 8/2/2002 CCA---

O nrdor~iw~nte'ssngznee, Ti ti e Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components descnrbed in this Owner's Report during the period 2-/(-02.- to r,--.-) Z-. , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

)seComissions: /-48 ' Z a B"4t17e an Eorseent InspectoT/s Signature National Board, Stater, and Endorsements Date* _* . 200_Z_*

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xl

1. Owner:

Calvert Cliffs Nuclear Powe# Plant, Inc. Date: 81112002 (name) 1650 Calvert Cliffs Parkway; Lusby, MD .20657 Sheet I of A-.

-- (address)

Calvert Cliffs Nuclear Power Plant Unit: One

2. Plant:

(name) -

R&R No. SG-1-002d,.ESP No. ES199601526 1650 Calvert Cliffs Parkway; Lusby, MD 20657 (address) S(P.O. no, Job no., etc.).

Type Code Symbol Stamp: N/A

3. Work Performed by: Calvert Cliffs Nuclear Power Plant Dept. Authorization No.: N/A (name) Exp Date: N/A Section XI Class: One 1650 Calvert Cliffs Parkway, Lusby, MD 20657 (address)
4. Identification of System: SystemNumber, 064 _System Name:, Reactor Coolant System Add; Class One' 5 .(a) Applicable Construction Code and Class: . ASME B31.7 1969 Editibn,Summer 1971 for Repairs/Replacement 1998 Edition (b) Applicable Sect XU Ed.
6. identification of Components Repaired or Replaced and Replacement Components: -:ASME Code "Repaired, Manufacturers National Year Replaced, oe Stamped Name of - Name of Board No.. Identification, Built Replacemen (Yes or No)

I Componet --Manufacturer Serial Number Repalred/RepI No 1" & under CC-9 N/A Reactor Cooling Sys. 1970 Repalred/Repl aced No Piping System Bechtel Instrumentation 2001 Replacement ES 199601526-112 N/A Tubing, 3/4 in. X .065 Wall, -

No Tubing SGT-Rcactor ASMESA213, Tp. 316 Coolant Flow Indication Replacement ES199601526-112 N/A Clamp, Tube, 314 In., 2 2001 No 2D Tubing SGT-Reactor Directional, Mark#400, Girard Clamp Coolant Flow . P/N 3/4T-SS-2D, A/SA 276 or479,

-

  • Indication Tp. 3041316 2001 Replacement ES199601526-112 NIA Union, Tubing, 3/4 in. Swagelok, No Tubing Union SGT-Reactor PIN SS-12-TSW-6, ASTM/ASME Coolant Flow A/SA182 or A/SA479, Tp. 316 Indication Replacement N/A Pipe, 1In. Sch 80, ASME SA-376, 2001 No Pipe SGT-Reactor ES199601526-112 Coolant Flow TP-316 Indication Replacement NIA Fitting, 1 in. X 3/4 in. Pipe/iubIng 2001 No Fitting SGT-Reactor ES199601526-112 Connector, Parker, PIN 12-1-AW Coolant Flow Indication
7. Description of Work:

and This plan was for the Reactor Coolant System Instrumentation Piping/Tubing and supports, one inch under, work to support the replacement of #12 Steam Generator.

Pneumaticf] Nominal Operating Pressure: Inservice: [3 Leakage E] Functional El

8. Tests Conducted: Hydrostattc:-

Pressure: N/A psi. Test Temperature: N/A Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

and the (2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered

.. ,,,,,hp- ,'F-,-'pt: i-cre-rorded at the tot of this form.

I-Sheet &of ;L FORM NIS-2o (Back)

-9. Remarks:

No Section Xl Pre-Service NDE was performed in support of this activity.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this RepalrlReplacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/KA Certificate of Authorization No.: N/A Expiration Date: NI/A

,L~ Q /~ 2 //Charles H.Ballard Signed: Engineering Technician Date: 8/1/2002 Owner or Owner's Designee, Title ICertificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston; RI have inspected the components described in this Owner's Report during the period '2 - ) Z__" to - (0 _._ , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspectionx

-- I J sJ/, g-atr Commissions: tatI an Edr Board8,Z( ) t Inspector's Signature National Board, Stat;. and Endorsements Datea-mz4L4-.. 200 Z- I

FORM NIS-2 OWNER'S REPORT FOR REPAIR I REPLACEMENT ACTIVITY As Required Required by the Provisions of the ASME Code Section Xl

1. Owner: Calvert Cliffs Nuclear Power Plant, Inc. Date: -8/1/2002 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 -_-. . Sheet 1 6f  ;.t

-- - (address) ...

2. Plant: Calvert Cliffs Nuclear Power Plant 'unit: One (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. SG-1-002e, ESP No. ES199601526 (address) (P.O.no.,jobno,etc) --

Type Code Syinbol Stamp: N/A

3. WorkPerformedby: Calvert Cliffs Nuclear Power Plan-t Dept. Authorization No.: N/A (name)

Exp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XIClass: One &Two (address)

4. Identification of System: SystemNumber 64/83 .. SystemName:., Steam Generator Replacement 5.(a) Applicable Construction Code and Class: AISC, Manual of Steel Construction, 6th Ed. 1963 (b) Applicable Sect XI Ed. for Repairs/Replacement . 1998 Edition
6. Identification of Components Repaired or Replaced and Replacement Components: Y ASME "RRepaired, Code' Name of Name of Manufacturers' National Other , Year Repl-aced, ox Starnpee Componet Manufacturer Serial Number Board No. Identification Built Replacemen (Yes or No)

Comp. Support Combustion' N/A N/A 012 Steam Generator Snubber '1970 Repaired/Repi - No Engineering and Sliding Base aced Plate SGT-Steam ES199601526-107 N/A Plate, Steel 114 in. ASME SA-36 2001 Replacement No SGenerator Supports Stud, 2 1/4 In. X 14 In. X 4 1/2 2001 Repiacement No Stud *SGT-Steam* ='° ES199601526-107 NIA Generator Supports - TPI, ASTM A-193, Gr. B7 Nut SGT-Steam ES199601526-107 N/A Nut, Heavy Hex, 2 1/4 in. X 4 1/2 2001 Replacement No Generator Supports TPI, ASTM A-194 Gr. 7 .

Nut SGT-Steam ES199601526-107 N/A -Washer, 2 114 In., Circular --- 2001 Replacement - No Generator Supports Hardened, ASME SA-193 Gr. B7 Plate SGT-Steam ES199601526-107 N/A Plate, 1/2 in., ASTM B-22, Tp. E 2001 Replacement No Generator Supports Plate SGT-Steam ES199601526-107 N/A Plate, Shim, AISI 4140, 125 RMS 2001 Replacement No Generator Supports Finish, Heat-Treat to RC-40 Capscrew SGT-Steam ES199601526-107 NIA Capscrew, 1/2 In. X 13 TPI, UNC 2001 Replacement No Generator Supports 3A, Socket-Head, Countersunk per ASTM F-835

7. Description of Work:

This plan was for the work on the Sliding base and the brackets that hold #12 Steam Generator in place.

8. Tests Conducted: Hydrostatic-[] Pneumatic'l Nominal Operating Pressure. Inservice. El Leakage El Functional.E]

Pressure: NIA psi. Test Temperature: N/A Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 3.of 0-FORM NIS-2 (Back)

9. Renar's" "

A Section XA VT-3 Visual Examination of the affected component support was performed prior to the system being returned to service.

Applicable Manufacturer's Data Reports to be Attached

" - Certificate-of Compliance We certify that the statements made in this report are correct and that this Repair/Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A ExpirationDate: N/A Charles H. Ballard Signed: Engineering Technician-' Date: 8/1/2002

""wneror Owner's ~esignee, Tare Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components described in this Owner's Report during the period 2-//-4O 7_-. to ,-Z -0Z ,and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinatioiis and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his "employershall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

Commissions: ,t{*C'22- A/J . ,flA<4/7

" Signature

" 6rrspegor's National Board, Stateland Endorsements Date 2002 -

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the Provisl6ns of the ASME Code Section XI

1. Owner: Calvert Cliffs Nuclear Power Plant, Inc. Date: 81112002 (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 Sheet i of 2

- (address)

2. Plant: Calvert Cliffs Nuclear Power Plant Unit: One, (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. SG-1-003, ESP No. ES199601526 (address) (P.O. no job no, etc )

Type Code Symbol Stamp: N/A

3. Work Performed by: Calvert Cliffs Nuclear Power Plant Dept. Authorization No.: N/A (name)

Exp Date: N/A "

1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class: One (address)

4. Identification of System: System Number 064 System Name: Reactor Coolant System 5.(a) Applicable Construction Code and Class: ASME B31.7 1969 Edition, Summer 1971 Add; Class One:

(b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition

6. Identification of Components Repaired or Replaced and Replacement Components: ASME Repaired, Code Name of Name of Manufacturers National Other Year Replaced, o0 Stamped

,Componet Manufacturer Serial Number Board No. Identification "Built Replacemen (Yes or No) 1970- Repaired/Repi No Piping System Bechtel 1" & under CC-9 N/A Reactor Cooling Sys.

Instrumentation aced

7. Description of W6rk:

This plan was for the Reactor Head Vent Piping/Tubing and supports, one inch and under, work to support the replacement of the Steam Generators.

8. Tests Conducted: Hydrostatic:E] Pneumatic[] Nominal Operating Pressure: Inservice: [:) Leakage: [] Functional: El Pressure: N/._A psi. Test Temperature: N/_AA Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks:

No Section XI Pre-Service NDE was performed in support of this activity.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance Rpropeet on msoh We certify that the statements made in this report are correct and that this Repair/RepIacement conforms to the rules of the ASME Code, Sectioii XI.

"Type Code Symbol Stamp: N/A Certificate of Authorization No.: N/A Expiration Date: N/A Charles H.Ballard Signed: - /, Engineering Technician Date: 8/1/2002 Owner or Owner's Designee, Title I Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maryland and employed by Factory Mutual Insurance Co. of Johnston, RI have inspected the components described in this Owner's Report during the period Z-/(-I Z.. to 6-2 0?... , and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

Commissions: Anseersgau ted-AlBar, os n lnspe sSintr National Board, State, anid Endorsements Dae J 200 Z

FORM NIS-2 OWNER'S REPORT FOR REPAIR / REPLACEMENT ACTIVITY As Required Required by the'Provisions of the ASiME Code Section X1

1. Owner: Calvert Cliffs Nuclear Power Plant,-Inc. Date: 6121/2002 (name) 1650 Calvert Cliffs Parkway;, Lusby, MD. 20657 Sheet 1 of 2 S(address) . ..

t ' "

2. Plant:' Calvert Cliffs Nuclear Power Plant Unit: Common (name) 1650 Calvert Cliffs Parkway; Lusby, MD 20657 R&R No. SNUB-0-002, MWO No. SNUB POOL (address) (P.O. no,job no., etc.)
3. WorkPerformed by: Cliffs Nuclear Power Plant Depti.

Calvert (name) Ccie Authorization No.: N/A I IExp Date: N/A 1650 Calvert Cliffs Parkway, Lusby, MD 20657 Section XI Class: 1, 2, & 3 (address)

4. Identification of System: - System Number 065B System Name: Seismic Snubbers 5.(a) Applicable Construction Code and Class: ASME B31.1.0 1967 Ed, 1972 Add, B31.7 1969 Ed, Sum. 1971 Add. or Combustion Eng. Spec 8067-487-503 (b) Applicable Sect XI Ed. for Repairs/Replacement 1998 Edition
6. Identification of Components Repaired or Replaced and Replacement Components: .ASME

- Repaired, Code Name of Name of Manufacturers National Other Year Replaced, or Stamped Componet Manufacturer Serial Number Board No. Identification Built Replacement (Yes or No)

Snubber Pool Grinnell Snubber Pool N/A Hydraulic Shock and Sway 1975 Repaired/Repi No Corporation Suppressor aced SSnubber Grinnell 59013-GX SN: 32307 N/A Hydraulic Shock and Sway 1991 - Replacement No Corporation Suppressor, 2-1/2" Bore by 5" Stroke, Fig. 200

7. Description of Work:

This plan was for the continued control of the Snubber Pool and documentation of new components/parts added to the Snubber Pool per Section Xl 1998, IWA-4132, Items Rotated From Stock. This Plan was for all Snubber work from the end of Unit #2, 2001 outage through to the end of Unit #1, 2002 outage.

8. Tests Conducted: Hydrostatic F1 Pneumaticf' Nominal Operating Pressure. Inservice: ] Leakage: [] Functional" ]

Pressure: N/A psi. Test Temperature: N/A Deg. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2, FORM NIS-2 (Back)

9. Remarks:*

A Section Xl VT-3 Visual Examination of the affected component support was performed prior to the system being returned to service.

Applicable Manufacturer's Data Reports to be Attached Certificate of Compliance We certify that the statements made in this report are correct and that this' Repalr/Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp: N/A Certificate of Authorization No.: NIA Expiration Date: N/A Signed: Charles H. Ballard Signed: /..................... VEngineering Technician Date: 6/21/2(002 OwneroOwnes fesignee, Title Certificate of Inservice Inspection I, the undersigned, holding a valid comrmission issued by the National Board of Boiler and Pressure Vessel InspeIctors and the State of Maryland and employed by Factory Mutual Insurarnce Co'. of Johnston, RI have inspected the components described in this Owner's Report during the period S--Z3-O to 2 ., and state to the 1

best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warrant, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or propetty damage of a loi* of any kind arising from or "connected with this inspection. .

~ i ~Commissions:

Inspectojs Signature

/d2 89 CT2 s?-6,1'Z,.

National Board, State, and Endorsements Date: 'ý.20 2002_ _