Lewis Sumner Southern Nuclear Vice President Operating Company, Inc.
Hatch Project Support 40 Inverness Parkway Post Office Box 1295 Birmingham, Alabama 35201 Tel 205.992.7279 Fax 205.992 0341 SE Energy to Serve Your World" August 6, 2002 Docket Nos. 50-321 50-366 HL-6285 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D. C. 20555 Edwin I. Hatch Nuclear Plant Monthly Operating Reports Ladies and Gentlemen:
Enclosed are the July 2002 Monthly Operating Reports for Edwin I. Hatch Nuclear Plant Unit 1, Docket No. 50-321, and Unit 2, Docket No. 50-366. These reports are submitted in accordance with Technical Specifications 5.6.4.
Respectfully submitted, H. L. Sumner, Jr.
IFL/eb
Enclosures:
- 1. July Monthly Operating Report for Plant Hatch Unit 1
- 2. July Monthly Operating Report for Plant Hatch Unit 2 cc: Southern Nuclear Operating Company Mr. P. H. Wells, Nuclear Plant General Manager SNC Document Management (R-Type A02.001)
U. S. Nuclear Regulatory Commission, Washington D. C.
Mr. L. N. Olshan, Project Manager - Hatch U. S. Nuclear Regulatory Commission, Region II Mr. L. A. Reyes, Regional Administrator Mr. J. T. Munday, Senior Resident Inspector - Hatch Utility Data Institute, Inc.
Ms. Barbara Lewis - McGraw-Hill Companies
Enclosure 1 Plant Hatch Unit 1 Monthly Operating Report July 2002 Table of Contents Page Operating Data Report El-i Unit Shutdowns and Power Reductions El -2
OPERATING DATA REPORT Docket No.: 50-321 Unit Name: E. I. Hatch Unit 1 Date: August 1,2002 Completed By: S. B. Rogers Telephone: (912) 367-7781 x2279 Operating Status
- 1. Reporting Period: JULY 2002
- 2. Design Electrical Rating (Net MWe): 870
- 3. Maximum Dependable Capacity (Net MWe): 856 This Month Year To Date Cumulative 744.0 4,313.8 186,828.2
- 4. Number of Hours Reactor Was Critical:
Hours Generator On Line: 744.0 4,223.6 180,917.2 5.
0.0 0.0 0.0
- 6. Unit Reserve Shutdown Hours:
634,762 3,576,602 131,480,739
- 7. Net Electrical Energy Generated:
CHALLENGES TO MAIN STEAM SAFETY I RELIEF VALVES Date TgN. Event Description No challenges this month.
E1-1
UNIT SHUTDOWNS Docket No.: 50-321 Unit Name: E. I. Hatch Unit 1 Date: August 1, 2002 Completed By: S. B. Rogers Telephone: (912) 367-7781 x2279 Reporting Period: JULY 2002 Type Method of F: Forced Duration Shutting Cause/Corrective Actions No. Date s: Scheduted (Hours) Reason (1) Down (2) Comments No unit shutdowns occurred this month.
(1) Reason: (2) METHOD A-Equipment Failure (Explain) 1-Manual B-Maintenance or Test 2-Manual Trip/Scram C-Refueling 3-Automatic Trip/Scram D-Regulatory Restriction 4-Continuation E-Operator Training/License Examination 5-Other (Explain)
F-Administrative G-Operational Error (Explain)
H-Other (Explain)
CAUSE/CORRECTIVE ACTION/COMMENTS:
NARRATIVE REPORT Unit 1 began the month of July operating at rated thermal power. Shift reduced load to approximately 860 GMWe (-2650 CMWT) on 7/6/02 to perform control rod drive exercises. The unit was returned to rated thermal power later the same day. Shift reduced load to approximately 520 GMWe (-1740 CMWT) on 7/12/02 to perform a control rod sequence exchange. Scram time testing, turbine control valve testing, and turbine stop valve testing were also performed while at reduced load. Shift began power ascension on 7/13/02 and the unit attained rated thermal power on 7/14/02. Shift reduced load to approximately 875 GMWe (-2680 CMWT) on 7/17/02 to perform a rod pattern adjustment. The unit was returned to rated thermal power later the same day. Shift reduced load to approximately 860 GMWe (-2705 CMWT) on 7/18/02 due to elevated condensate temperatures and a decrease in main condenser vacuum. The unit was returned to rated thermal power on 7/19/02. Shift reduced load to approximately 855 GMWe
(-2650 CMWT) on 7/20/02 to perform control rod drive exercises. The unit was returned to rated thermal power on 7/21/02. Shift reduced load to approximately 855 GMWe (-2645 CMWT) on 7/27/02 to perform control rod drive exercises. The unit was returned to rated thermal power later the same day. Shift maintained unit operation at rated thermal power for the remainder of the month.
El -2
Enclosure 2 Plant Hatch Unit 2 Monthly Operating Report July 2002 Table of Contents Page Operating Data Report E2-1 Unit Shutdowns and Power Reductions E2-2
OPERATING DATA REPORT Docket No.: 50-366 Unit Name: E. I. Hatch Unit 2 Date: August 1, 2002 Completed By: S. B. Rogers Telephone: (912) 367-7781 x2279 Operating Status
- 1. Reporting Period: JULY 2002
- 2. Design Electrical Rating (Net MWe): 894
- 3. Maximum Dependable Capacity (Net MWe): 870 This Month Year To Date Cumulative
- 4. Number of Hours Reactor Was Critical: 744.0 4,891.6 162,994.2
- 5. Hours Generator On Line: 744.0 4,871.8 158,646.9
- 6. Unit Reserve Shutdown Hours: 0.0 0.0 0.0
- 7. Net Electrical Energy Generated: 646,387 4,241,676 117,436,292 CHALLENGES TO MAIN STEAM SAFETY I RELIEF VALVES DaeTag No. Event Description No challenges this month.
E2-1
UNIT SHUTDOWNS Docket No.: 50-366 Unit Name: E. I. Hatch Unit 2 Date: August 1, 2002 Completed By: S. B. Rogers Telephone: (912) 367-7781 x2279 Reporting Period: JULY 2002 Type Method of F: Forced Duration Shutting Cause/Corrective Actions No. Date s: scheduled (Hours) Reason (1) Down (2) Comments No unit shutdowns occurred this month.
(1) Reason: (2) METHOD A-Equipment Failure (Explain) 1-Manual B-Maintenance or Test 2-Manual Trip/Scram C-Refueling 3-Automatic Trip/Scram D-Regulatory Restriction 4-Continuation E-Operator Training/License Examination 5-Other (Explain)
F-Administrative G-Operational Error (Explain)
H-Other (Explain)
CAUSE/CORRECTIVE ACTION/COMMENTS:
NARRATIVE REPORT Unit 2 began the month of July operating at rated thermal power. Shift reduced load to approximately 870 GMWe (-2650 CMWT) on 7/7/02 to perform control rod drive exercises. The unit was returned to rated thermal power later the same day. Shift reduced load to approximately 870 GMWe (-2650 CMWT) on 7/14/02 to perform control rod drive exercises. The unit was returned to rated thermal power on 7/15/02.
Shift reduced load to approximately 835 GMWe (-2540 CMWT) on 7/21/02 to perform control rod drive exercises. Shift then increased power to approximately 98% of rated thermal and performed turbine stop valve testing. The unit was returned to rated thermal power later the same day. Shift reduced load to approximately 875 GMWe (-2650 CMWT) on 7/28/02 to perform control rod drive exercises. The unit was returned to rated thermal power on 7/29/02. Shift maintained unit operation at rated thermal power for the remainder of the month.
E2-2