Text
INSERVICE INSPECTION REPORT UNIT 2 MCGUIRE 2002 OUTAGE 6IEOC-14 Location: Hwy. 73, Cowans Ford, North Carolina 28216 NRC Docket No. 50-370 National Board No. 84 Commercial Service Date: March 1, 1984 Owner: Duke Energy Corporation 526 South Church St.
Charlotte, N.C. 28201-1006 Revision 0 Prepared By:
wviewed By:
Approved By:
kxcc
-I12 Date 51H/lO?
Date 5-O-O).
Date Z/
C)
Pages 187 FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules
- 1.
Owner: Duke Energy Corporation, 526 S. Church St., Charlotte, NC 28201-1006 (Name and Address of Owner)
- 2.
Plant: McGuire Nuclear Station, Highway 73 Cowans Ford, N.C. 28216 (Name and Address of Plant) 3 Plant Unit:
2
- 4. Owner Certificate of Authorization (if required) N/A
- 5.
Commercial Service Date: March 1,1984 6. National Board Number for Unit 84
- 7.
Components Inspected:
Component or Appurtenance Manufacturer or Manufacturer or Installer Installer Serial No.
State or Province No.
See Section 1.1 in the Attached Report Note: Supplemental sheets in form of lists, sketches, or drawings may be used provided (1) size is 81/2 in. x 11 in., (2) information in items 1 through 6 on this data report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
National Board No.
FORM NIS-1 (Back)
- 8.
Examination Dates October 14, 2000 to March 27, 2002 Inspection Period Identification:
- 10.
Inspection Interval Identification:
- 11.
Applicable Edition of Section XI
- 12.
Date/Revision of Inspection Plan:
Third Period Second Interval 1989 Addenda None September 7,1999/Revision 3
- 13.
Abstract of Examinations and Test. Include a list of examinations and tests and a statement concerning status of work required for the Inspection Plan.
See Sections 3.0, 4.0 and 11.0
- 14.
Abstract of Results of Examination and Tests.
- 15.
Abstract of Corrective Measures.
See Section 5.0 and 11.0 See Section 8.0 We certify that a) the statements made in this report are correct b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI, and c) corrective measures taken conform to the rules of the ASME Code,Section XI.
Certificate of Authorization No. (if applicable)
N/A Date Z
ZooZ., Signed Duke Energy Corp.
By Owner Expiration Date
-A CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commissioR issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Province of -
,10,;
employed by
- The HSBCT. of Connecticut have inspected the components described in this Owners' Report during the period
- j AiD.O Q to 5"-;2; - &D
.,, and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in the Owners' Report in accordance with the Inspection Plan and as required by the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, test, and corrective measures described in this Owners' Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection SCommissions zJB) 77&,5
,3*,e"---3 AJ Ir~lectef"Signature National Board, State, Province, 'ind Endorserrients Date I
- The Hartford Steam Boiler Inspection & Insurance Co. of Connecticut 200 Ashford Center North Suite 300 Atlanta, GA. 30338-4860 N/A A -*
- F_-
DISTRIBUTION LIST Duke Energy Corporation Quality Assurance Technical Services (Original Copy)
McGuire Mechanical Maintenance/ QA Technical Support NRC Document Control Hartford Steam Boiler Inspection and Insurance Company of Connecticut (AIA); ANII/McGuire State of North Carolina Department of Labor c/o J. M. Givens, Jr.
Nuclear GO Regulatory &
Industrial Affairs c/o Laura Burba Mail Code/ ECO50
TABLE OF CONTENTS Section Title Revision
- 1.
General Information 0
- 2.
Summary of Inservice Inspections 0
- 3.
Second Ten Year Inspection Status 0
- 4.
Final Inservice Inspection Plan 0
- 5.
Results of Inspections Performed 0
- 6.
Reportable Indications 0
- 7.
Personnel, Equipment, and Material Certifications 0
- 8.
Corrective Action 0
- 9.
Reference Documents 0
- 10.
Class 1 (Tab A) and 2(Tab B) Repairs and Replacements 0
- 11.
Pressure Testing 0
1.0 General Information This report describes the Inservice Inspection of Duke Energy Corporation's McGuire Nuclear Station Unit 2 during Outage 6/EOC-14. This is the First Outage of the Third Inspection Period of the Second Ten Year Interval.
Included in this report are the final Inservice Inspection Plan, the inspection results for each item, a summary for each category of examination and corrective action taken when unacceptable conditions were found. In addition, there is a section included for completed NIS-2 documentation of repairs and replacements.
1.1 Identification Numbers Manufacturer National Manufacturer or Installer State or Board Item or Installer Serial No.
Province No.
No.
Reactor Vessel Rotterdam 30664 NC-201819 Pressurizer Westinghouse 1491 NC-201818 W10285 Steam Generator 2A BWl 7700-02 NC-302674 159 Steam Generator 2B BWl 7700-04 NC-302675 161 Steam Generator 2C BWl 7700-01 NC-302676 158 Steam Generator 2D BWl 7700-03 NC-302677 160 Centrifugal Pacific Pumps 2A - 48584 N/A 25 Charging Pump 2B-48585 28 Containment Spray Heat Delta Southern Co.
2A-35005-73-3 NC-234203 3396 Exchanger 2B-35005-73-4 NC-201822 3397 Outage 6/EOC-14 McGuire Unit 2 Section 1 Page 1 of 4 Revision 0 May 17, 2002
1.1 Identification Numbers Continued Manufacturer National Manufacturer or Installer State or Board Item or Installer Serial No.
Province No.
No.
Excess Letdown Heat Westinghouse 1810 NC-234264 1555 Exchanger Letdown Heat Exchanger Joseph Oat & Sons, Inc.
2049-2B NC-201842 553 Reciprocating Charging Union Pump Co.
N721031 B-604 N/A 80 Pump 2A 5-114E841G02 Reactor Coolant Pump Westinghouse 2B 6-114E841 G02 N/A N/A 2C 7-114E841G02 2D 8-114E841G02 Reciprocating Charging Metal Bellows Company 74730-002 N/A 002 Pump Accumulator Reciprocating Charging Richmond Engineering N-2409.20 N/A 75220 Pump Suction Stabilizer Supply Co.
Residual Heat Joseph Oat & Sons, Inc.
2A 2046-2C NC-1 69800 637 Removal Heat 2B 2046-2D NC-201823 638 Exchanger Safety Injection Pump Pacific Pumps 2A 49357 N/A 130 2B 49358 131 Regenerative Heat Joseph Oat & Sons, Inc.
2047-2B NC-201817 628 Exchanger 629 630 Seal Water Heat Atlas Industrial 1767 NC 201827 1549 Exchanger Manufacturing Company Seal Water AMF Cuno 2A - 20 N/A 4364 Injection Filter 2B - 22 4365 Outage 6/EOC-14 McGuire Unit 2 Section 1 Page 2 of 4 Revision 0 May 17, 2002
S1.1 Identification Numbers Continued Manufacturer Manufacturer or Installer State or National Item or Installer Serial No.
Province No.
Board No.
Main Steam Supply to Duke Power Co.
SA N/A 62 Auxiliary Equipment System Containment Air Duke Power Co.
VQ N/A 56 Release and Addition System Main Steam System Duke Power Co.
SM N/A 70 Main Steam Vent to Duke Power Co.
SV N/A 67 Atmosphere System Reactor Coolant Duke Power Co.
NC N/A 82 System Liquid Waste Recycle Duke Power Co.
WL N/A 76 System Refueling Water Duke Power Co.
FW N/A 54 System Auxiliary Feedwater Duke Power Co.
CA N/A 73 System Residual Heat Duke Power Co.
ND N/A 63 Removal System Nuclear Service Water Duke Power Co.
RN N/A 60 System Chemical & Volume Duke Power Co.
NV N/A 80 Control System Component Cooling Duke Power Co.
KC N/A 78 System Main Feedwater Duke Power Co.
CF N/A 61 System Containment Spray Duke Power Co.
NS N/A 69 System Outage 6/EOC-14 McGuire Unit 2 Section 1 Page 3 of 4 Revision 0 May 17, 2002
1.1 Identification Numbers Continued Manufacturer Manufacturer or Installer State or National Item or Installer Serial No.
Province No.
Board No.
Containment Duke Power Co.
RV N/A 72 Ventilation Cooling Water System Safety Injection System Duke Power Co.
NI N/A 83 Unit 2 Duke Power Co.
N/A N/A 84 1.2 Authorized Name:
Employer:
Business Address:
Nuclear inservice Inspector(s)
R. D. Klein The Hartford Steam Boiler Inspection & Insurance Company of Connecticut The Hartford Steam Boiler Inspection & Insurance Co. of Connecticut 200 Ashford Center North Suite 300 Atlanta, GA 30338-4860 Outage 6/EOC-14 McGuire Unit 2 Section 1 Page 4 of 4 Revision 0 May 17, 2002
2.0 Summary of Inservice Inspections The information shown below provides an abstract of ASME Section XI Class 1, Class 2, and Augmented Items scheduled and examined during Outage 6/EOC-14 at McGuire Nuclear Station Unit 2.
2.1 Class 1 Inspection Examination Category B-A Pressure Retaining Welds in Reactor Vessel Outage 6/EOC-14 McGuire Unit 2 Section 2 Page 1 of 19 Revision 0 May 17, 2002 Item Description Total Examined Number During Outage B01.010 Shell Welds B01.011 Circumferential 0
B01.012 Longitudinal N/A B01.020 Head Welds B01.021 Circumferential 0
B01.022 Meridional 0
B01.030 Shell-to-Flange Welds 0
B01.040 Head-to-Flange Welds 0
B01.050 Repair Welds 801.051 Beltline Region N/A TOTALS 0
Examination Category B-B Pressure Retaining Welds in Vessels Other than Reactor Vessels Item Description Total Examined Number During Outage Pressurizer B02.01 0 Shell-to-Head Welds B02.011 Circumferential 1
B02.012 Longitudinal 1
B02.020 Head Welds B02.021 Circumferential N/A B02.022 Meridional N/A Steam Generators (Primary Side)
B02.030 Head Welds B02.031 Circumferential N/A B02.032 Meridional N/A B02.040 Tubesheet-to-Head Weld 0
N,
,,****Heat Exchangers S(Primary Side) -- Head B02.050 Head Welds B02.051 Circumferential N/A B02.052 Meridional N/A Heat Exchangers (Primary Side) -- Shell B02.060 Tubesheet-to-Head Welds N/A B02.070 Longitudinal Welds N/A B02.080 Tubesheet-to-Shell Welds N/A TOTALS 1
2 Outage 6/EOC-14 McGuire Unit 2 Section 2 Page 2 of 19 Revision 0 May 17, 2002
Examination Category B-D Full Penetration Welds of Nozzles in Vessels Inspection Program B Item Description Total Examined Number During Outage Reactor Vessel B03.090 Nozzle-to-Vessel Welds 0
B03.100 Nozzle Inside Radius Section 0
Pressurizer B03.110 Nozzle-to-Vessel Welds 0
B03.120 Nozzle Inside Radius Section 0
Steam Generators (Primary Side)
B03.130 Nozzle-to-Vessel Welds N/A B03.140 Nozzle Inside Radius Section 2
7.Heat Exchangers (Primary Side)
B03.150 Nozzle-to-Vessel Welds N/A B03.160 Nozzle Inside Radius Section N/A TOTALS 2
Examination Category B-E Pressure Retaining Partial Penetration Welds in Vessels REFERENCE SECTION 11.0 OF THIS REPORT Outage 6/EOC-14 McGuire Unit 2 Section 2 Page 3 of 19 Revision 0 May 17, 2002
Examination Category B-F Pressure Retaining Dissimilar Metal Welds Item Description Total Examined Number During Outage Reactor Vessel B05.010 Nominal Pipe Size 4" or Larger 4
Nozzle-to-Safe End Butt Welds B05.020 Nominal Pipe Size Less Than 4" N/A Nozzle-to-Safe End Butt Welds B05.030 Nozzle-to-Safe End Socket Welds N/A
- Pressurizer B05.040 Nominal Pipe Size 4" or Larger 0
Nozzle-to-Safe End Butt Welds B05.050 Nominal Pipe Size Less Than 4" N/A Nozzle-to-Safe End Butt Welds B05.060 Nozzle-to-Safe End Socket Welds N/A Steam Generator B05.070 Nominal Pipe Size 4" or Larger 4
Nozzle-to-Safe End Butt Welds B05.080 Nominal Pipe Size Less Than 4" N/A Nozzle-to-Safe End Butt Welds B05.090 Nozzle-to-Safe End Socket Welds N/A H-eat Exchangers B05.100 Nominal Pipe Size 4" or Larger N/A Nozzle-to-Safe End Butt Welds B05.1 10 Nominal Pipe Size Less Than 4" N/A Nozzle-to-Safe End Butt Welds B05.120 Nozzle-to-Safe End Socket Welds N/A Outage 6/EOC-14 McGuire Unit 2 Section 2 Page 4 of 19 Revision 0 May 17, 2002
Examination Category B-F (Continued)
B05.130 Pipinq Nominal Pipe Size 4" or Larger Dissimilar Metal Butt Welds 4
B05.140 Nominal Pipe Size Less Than 4" N/A Dissimilar Metal Butt Welds B05.150 Dissimilar Metal Socket Welds N/A TOTALS 12 Examination Category B-G-1 Pressure Retaining Bolting, Greater Than 2" in Diameter Item Description Total Examined Number During Outage Reactor Vessel B06.010 Closure Head Nuts 19 B06.020 Closure Studs (in place) 0 B06.030 Closure Studs (when removed) 19 B06.040 Threads in Flange 0
B06.050 Closure Washers, Bushings 19 Pressurizer B06.060 Bolts and Studs N/A B06.070 Flange Surface (when connection N/A disassembled)
B06.080 Nuts, Bushings, and Washers N/A Steam Generators B06.090 Bolts and Studs 4
B06.100 Flange Surface (when connection 4
disassembled)
B06.110 Nuts, Bushings, and Washers 4
Outage 6/EOC-14 McGuire Unit 2 Section 2 Page 5 of 19 Revision 0 May 17, 2002 I
Examination Category B-G-1 Heat Exchangers l
B06.120 Bolts and Studs N/A B06.130 Flange Surface (when connection N/A disassembled)
B06.140 Nuts, Bushings, and Washers N/A B06.150 Bolts and Studs N/A B06.160 Flange Surface (when connection N/A disassembled)
B06.170 Nuts, Bushings, and Washers N/A Pumps B06.180 Bolts and Studs 1
B06.190 Flange Surface' 0
(when connection disassembled)
B06.200 Nuts, Bushings, and Washers N/A S.
Valves B06.21 0 Bolts and Studs N/A B06.220 Flange Surface' N/A (when connection disassembled)
B06.230 Nuts, Bushings, and Washers N/A TOTALS 70 1 Items disassembled will be examined but will not be counted in the totals or percentages for the B-G-1 category. These items will be listed in sections 4 and 5 of the applicable report.
Outage 6/EOC-14 McGuire Unit 2 Section 2 Page 6 of 19 Revision 0 May 17, 2002 (Continued)
Examination Category B-G-2 Pressure Retaining Bolting, 2" and Less in Diameter Item Description Total Examined Number During Outage
- Ii
!Reactor Vessel B07.010 Bolts, Studs, and Nuts N/A Pressurizer B07.020 Bolts, Studs, and Nuts 0
Steam Generators B07.030 Bolts, Studs, and Nuts 0
Heat Exchangers B07.040 Bolts, Studs, and Nuts N/A Piping B07.050 Bolts, Studs, and Nuts 2
~4
~,Pumps B07.060 Bolts, Studs, and Nuts 0
Valves B07.070 Bolts, Studs, and Nuts 3
B07.080 Bolts, Studs, and Nuts in ORD 0
Housing when disassembled 2 TOTALS 5
2 Items disassembled will be examined but will not be counted in the totals or percentages for the B-G-2 category. These items will be listed in sections 4 and 5 of the applicable report.
Outage 6/EOC-14 McGuire Unit 2 Section 2 Page 7 of 19 Revision 0 May 17, 2002
Integral Attachments for Vessels Examination Category B-J Pressure Retaining Welds in Piping Item Description Total Examined Number During Outage B09.010 Nominal Pipe Size 4" or Larger j
B09.011 Circumferential Welds 23 B09.012 Longitudinal Welds 3 N/A B09.020 Nominal Pipe Size Less than 4" B09.021 Circumferential Welds 5
B09.022 Longitudinal Welds 3 N/A Outage 6/EOC-14 McGuire Unit 2 Section 2 Page 8 of 19 Revision 0 May 17, 2002 Examination Category B-H Item Description Total Examined Number During Outage Reactor Vessel B08.010 Integrally Welded Attachments 0
Pressurizer A:1A B08.020 Integrally Welded Attachments 2
Steam Generators B08.030 Integrally Welded Attachments N/A Heat Exchangers B08.040 Integrally Welded Attachments N/A TOTALS 2
Examination Category B-J B09.030 Rnq 031 Branch Pipe Connection Welds Nominal Pine Size 4" or Laraer 0
B09.032 Less than Nominal Pipe Size 4" 3
B09.040 Socket Welds 13 TOTALS 44 SLongitudinal welds in Exam ination Category B-J that intersect circum ferential welds are exam ined per Code Case N-524.
Examination Category B-K-1 Integral Attachments for Piping, Pumps and Valves Description Total Examined During Outage Piping Integrally Welded Attachments N/A Pumps Integrally Welded Attachments N/A Valves I ntea]rallv Welded Attachments N/A
[
-TOTALS N/A Outage 6/EOC-14 McGuire Unit 2 Section 2 Page 9 of 19 Revision 0 May 17, 2002 Item B10.030 I
(Continued)
Examination Category B-L-l, B-M-1 B-L-2, B-M-2 Pressure Retaining Welds in Pump Casings and Valve Bodies Pump Casings and Valve Bodies Item Description Total Examined Number During Outage Pumps B12.010 Pump Casing Welds (B-L-1)
N/A B12.020 Pump Casing (B-L-2) 0 (when disassembled for Maintenance Repair or Volumetric Examination)
Valves B12.030 Valves, Nominal Pipe Size Less than N/A 4" Valve Body Welds (B-M-1)
B12.040 Valves, Nominal Pipe Size 4" or N/A Larger Valve Body Welds (B-M-1)
B1 2.050 Valve Body, Exceeding 4" Nominal 0
Pipe Size (B-M-2)
TOTALS 0
Examination Category B-N-1 Interior of Reactor Vessel B-N-2 Integrally Welded Core Support Structures and Interior Attachments to Reactor Vessels B-N-3 Removable Core Support Structures Item Description Total Examined Number During Outage Reactor Vessel A
,l B13.010 Vessel Interior (B-N-l) 0 Outage 6/EOC-14 McGuire Unit 2 Section 2 Page 10 of 19 Revision 0 May 17, 2002
Examination Category B-N-i, B-N-2, B-N-3 (Continued)
Reactor Vessel (PWR)
B13.050 Interior Attachments Within the Beitline Reaion (B-N-2)
N/A B13.060 Interior Attachments Beyond Beltline 0
Region (B-N-2)
B13.070 Core Support Structure (B-N-3) 0 TOTALS
_L 0
Examination Category B-O Pressure Retaining Welds in Control Rod Housings Examination Category B-PAll Pressure Retaining Components REFERENCE SECTION 11.0 OF THIS REPORT Outage 6/EOC-14 McGuire Unit 2 Section 2 Page 11 of 19 Revision 0 May 17, 2002 Item Description Total Examined Number During Outage Reactor Vessel B14.010 Welds in CRD Housing 1
TOTALS 1
Examination Category B-Q Note: Steam Generator Tubing is examined and documented by the Steam Generator Maintenance Group of the Station Support Division as required by the Station Technical Specifications and is not included in this report.
Examination Category F-A Class 1 Component Supports Outage 6/EOC-14 McGuire Unit 2 Section 2 Page 12 of 19 Revision 0 May 17, 2002 Item Description Total Examined Number During Outage F01.010 Class 1 Piping Supports (Code Case 17 N-491 applies) Reference Section 4.0 1 of this report TOTALS 1
17 Steam Generator Tubing
2.2 Class 2 Inspections Examination Category C-A Examination Category C-B Pressure Retaining Welds in Pressure Vessels Pressure Retaining Nozzle Welds in Vessels Item Description Total Examined Number During Outage C02.010 Nozzles in Vessels < 1/2" Nominal Thickness C02.011 Nozzle-to-Shell (or Head) Weld 2
C02.020 Nozzles Without Reinforcing Plate in Vessels >1/2" Nominal Thickness C02.021 Nozzle-to-Shell (or Head) Weld 0
C02.022 Nozzle Inside Radius Section 4 0
Outage 6/EOC-14 McGuire Unit 2 Section 2 Page 13 of 19 Revision 0 May 17, 2002 Item Description Total Examined Number During Outage C01.010 Shell Circumferential Welds 1
C01.020 Head Circumferential Welds 2
C01.030 Tubesheet-to-Shell Weld 2
TOTALS 5
Examination Category C-B(
C02.030
.4-C02.031 Nozzles With Reinforcing Plate in Vessels >1/2" Nominal Thickness Reinforcing Plate Welds to Nozzle and Vessel 0
C02.032 Nozzle-to-Shell (or Head) Welds N/A when Inside of Vessel is Accessible C02.033 Nozzle-to-Shell (or Head) Welds
- 0 when Inside of Vessel is Inaccessible TOTALS 2
- Note: This item will be examined lAW Examination Category C-H. For reporting results reference Section 11 of this report.
4 (Item # C02.022) Nozzle Inside Radius Section welds are examined as required by Table IWC 2500-1 Category C-B. However, for reporting purposes, the totals do not reflect the number of Nozzle Inside Radius Section welds examined during this outage. Nozzle Inside Radius Section welds are to be examined in conjunction with C02.021. examinations.
Examination Category C-C Integral Attachments for Vessels, Piping, Pumps, and Valves Description Total Examined Pressure Vessels C03.010 Integral Welded Attachments Piping Intecirallv Welded Attachments Pumps Intearallv Welded Attachments I
n 1
Valves____________
C03.040 Integrally Welded Attachments N/A TOTALS 1
Outage 6/EOC-14 McGuire Unit 2 Section 2 Page 14 of 19 Revision 0 May 17, 2002 Item Number
('..I3R O~
(Continued)
Examination Category C-D Pressure Retaining Bolting Greater Than 2" in Diameter Item Description Total Examined Number During Outage Pressure Vessels C04.010 Bolts and Studs N/A Piping C04.020 Bolts and Studs N/A Pumps 004.030 Bolts and Studs N/A Valves C04.040 Bolts and Studs N/A TOTALS N/A Examination Category C-F-1 Pressure Retaining Welds in Austenitic Stainless Steel or High Alloy Piping Item Description Total Examined Number During Outage C05.010 Piping Welds > 3/8" Nominal Wall Thickness for Piping > Nominal Pipe Size 4" C05.011 Circumferential Weld 14 C05.012 Longitudinal Weld5 See Code Case N-524 Outage 6/EOC-14 McGuire Unit 2 Section 2 Page 15 of 19 Revision 0 May 17, 2002
Examination Category C-F-1 C05.020 Piping Welds > 1/5" Nominal Wall Thickness for Piping _> Nominal Pipe Size 2" and < Nominal Pipe Size 4" fl05_021 Circumferential Weld 12 C05.022 Longitudinal Weld5 N/A C05.030 Socket Welds 9
C05.040 Pipe Branch Connections of Branch Piping > Nominal Pipe Size 2" C05.041 Circumferential Weld 1
C05.042 Longitudinal Weld5 N/A TOTALS 36 5Longitudinal welds in Examination Categories C-F-1 and C-F-2 that intersect circumferential welds are examined per Code Case N-524.
Examination Category C-F-2 Pressure Retaining Welds in Carbon or Low Alloy Steel Piping Item Description Total Examined Number During Outage C05.050 Piping Welds > 3/8" Nominal Wall Thickness for Piping > Nominal Pipe Size 4" C05.051 Circumferential Weld 10 C05.052 Longitudinal Weld5 See Code Case N-524 Outage 6/EOC-14 McGuire Unit 2 Section 2 Page 16 of 19 Revision 0 May 17, 2002 (Continued)
Examination Category C-F-2 C05.060
+/-
r.r ni Piping Welds > 1/5" Nominal Wall Thickness for Piping > Nominal Pipe Size 2" and < Nominal Pipe Size 4" flimiimfprpntiI WId N/A C05.062 Longitudinal Weld5 N/A C05.070 Socket Welds N/A C05.080 Pipe Branch Connections of Branch Piping _> Nominal Pipe Size 2" C05.081 Circumferential Weld N/A C05.082 Longitudinal Weld5 N/A TOTALS 10 5Longitudinal welds in Examination Categories C-F-1 and C-F-2 that intersect circumferential welds are examined per Code Case N-524.
Examination Category C-G Pressure Retaining Welds in Pumps and Valves Item Description Total Examined Number During Outage Pumps C06.010 Pump Casing Welds N/A Valves C06.020 Valve Body Welds TOTALS 1
Examination Category C-H All Pressure Retaining Components REFERENCE SECTION 11.0 OF THIS REPORT Outage 6/EOC-14 McGuire Unit 2 Section 2 Page 17 of 19 Revision 0 May 17, 2002 (Continued)
Examination Category F-AClass 2 Component Supports Item Description Total Examined Number During Outage F01.020 Class 2 Piping Supports (Code Case 40 N-491 applies) Reference Section 4.0 of this report TOTALS 1
40 Examination Category F-ASupports Other than Piping Supports Item Description Total Examined Number During Outage F01.040 Supports other than Piping Supports 10 Class 1, 2, & 3 (Code Case N-491 applies) Reference Section 4.0 of this report TOTALS 10 Examination Category Component Supports Class 1, 2, & 3
- Examinations to be performed per Request for Relief 97-005 Outage 6/EOC-14 McGuire Unit 2 Section 2 Page 18 of 19 Revision 0 May 17, 2002 Item Description Total Examined Number During Outage F01.050 Component supports snubbers Class
- N/A 1,2&3 TOTALS
- N/A
2.3 Augmented Inspection Outage 6/EOC-14 McGuire Unit 2 Section 2 Page 19 of 19 Revision 0 May 17, 2002 Item Total Examined Number Description During Outage GO1.001 RCP Flywheel Exam 0
G03.001 Pipe Rupture Protection 2
TOTALS 2
3.0 Second Ten Year Interval Inspection Status The completion status of inspections required by the 1989 ASME Code Section XI, no Addenda is summarized in this section. The requirements are listed by the ASME Section XI Examination Category as defined in Table IWB-2500-1 for Class 1 Inspections, Table IWC-2500-1 for Class 2 Inspections, and IWF-2500 1 (Code Case N-491 applies) for Class 1, 2 and 3 Component Supports.
Augmented inspections are also included.
Class 1 Inspections Examination Description Inspections Inspections Percentage 6Deferral Category Required Completed Completed Allowed B-A Pressure Retaining Welds 15 3
20.00%
Yes in Reactor Vessel B-B Pressure Retaining Welds 5
5 100%
No in Vessels Other than Reactor Vessels B-D Full Penetration Welds of 36 24 66.66%
Partial Nozzles in Vessels Inspection Program B B-E Pressure Retaining Partial Penetration Welds in Vessels REFERENCE SECTION 11.0 OF THIS REPORT B-F Pressure Retaining 38 28.66 75.42%
No Dissimilar Metal Welds B-G-1 Pressure Retaining Bolting 237 229 96.62%
No Greater than 2" in Diameter B-G-2 Pressure Retaining Bolting 22 19 86.36%
No 2" and Less in Diameter Outage 6/EOC-14 McGuire Unit 2 Section 3 Page 1 of 5 Revision 0 May 17, 2002
Class 1 Inspections (Continued)
Examination Description Inspections Inspections Percentage 6Deferral Category Required Completed Completed Allowed B-H Integral Attachments for 13 9
69.23%
No Vessels B-J Pressure Retaining Welds 197 169 85.78%
No in Piping B-K-1 Integral Attachments for N/A N/A N/A No Piping, Pumps and Valves B-L-1 Pressure Retaining Welds N/A N/A N/A Yes in Pump Casings B-L-2 Pump Casings 1
0 00.00%
Yes B-M-1 Pressure Retaining N/A N/A N/A Yes Welds in Valve Bodies B-M-2 Valve Body > 4 in.
6 3
50.00%
Yes Nominal Pipe Size B-N-1 Interior of Reactor Vessel 3
2 66.66%
No B-N-2 Integrally Welded Core 2
0 00.00%
Yes Support Structures and Interior Attachments to Reactor Vessels B-N-3 Removable Core Support 1
0 00.00%
Yes Structures B-O Pressure Retaining Welds 3
3 100%
Yes in Control Rod Housings Outage 6/EOC-14 McGuire Unit 2 Section 3 Page 2 of 5 Revision 0 May 17, 2002
Class 1 Inspections (Continued)
Examination Description Inspections Inspections Percentage 6Deferral Category Re uired Completed Completed Allowed B-P All Pressure Retaining REFERENCE SECTION 11.0 OF THIS REPORT Components B-Q Steam Generator Tubing See Note below F-A Class 1 Component 49 49 100%
No F01.010 Supports (Code Case N-491)
Note: Steam Generator Tubing is examined and documented by the Steam Generator Maintenance Group of the Station Support Division as required by the Station Technical Specifications and is not included in this report.
6 Deferral of inspection to the end of the interval as allowed by ASME Section XI Tables IWB and IWC 2500-1 Outage 6/EOC-14 McGuire Unit 2 Section 3 Page 3 of 5 Revision 0 May 17, 2002
Class 2 Inspections Examination Description Inspections Inspections Percentage 6Deferral Category Required Completed Completed Allowed C-A Pressure Retaining Welds 25 21 84.00%
No in Pressure Vessels C-B Pressure Retaining Nozzle 22 16 72.72%
No Welds in Vessels C-C Integral Attachments for 6
6 100%
No Vessels, Piping, Pumps, and Valves C-D Pressure Retaining Bolting N/A N/A N/A No Greater Than 2" in Diameter C-F-1 Pressure Retaining Welds 251 196 78.08%
No in Austenitic Stainless Steel or High Alloy Piping C-F-2 Pressure Retaining Welds 51 41 80.39%
No in Carbon or Low Alloy Steel Piping C-G Pressure Retaining Welds 6
5 83.33%
No in Pumps and Valves C-H All Pressure Retaining REFERENCE SECTION 11.0 OF THIS REPORT Components F-A Class 2 Component 181 156 86.18%
No Supports F01.020 (Code Case N-491) 6 Deferral of inspection to the end of the interval as allowed by ASME Section XI Tables IWB and IWC 2500-1 Outage 6/EOC-14 McGuire Unit 2 Section 3 Page 4 of 5 Revision 0 May 17, 2002
Additional Component Support Examinations Class 1, 2 & 3 Examination Description Inspections Inspections Percentage 6Deferral Category Required Completed Completed Allowed F-A Supports other than Piping 36 32 88.88%
No F01.040 Supports Class 1, 2 & 3 (Code Case N-491 applies)
I Examination Description Inspections Inspections Percentage 6Deferral Category Required Completed Completed Allowed F-A Component Supports No F01.050 Snubbers Class 1, 2 & 3 6 Deferral of inspection to the end of the interval as allowed by ASME Section X1 Tables IWB-2500-1 and IWC-2500-1.
- Examinations to be performed per Request for Relief 97-005 Augmented Inspections Description Percentage Complete Reactor Coolant Pump Flywheels (Item No. Series GO1.)
100% of requirements for OUTAGE 6/EOC-14 Pipe Rupture Protection (Item No. Series G03.)
100% of requirements for OUTAGE 6/EOC-14 Outage 6/EOC-14 McGuire Unit 2 Section 3 Page 5 of 5 Revision 0 May 17, 2002
4.0 Final Inservice Inspection Plan The final ISI Plan shown in this section lists all ASME Section Xl Class 1 and Class 2, and Augmented examinations credited for Outage 6/EOC-1 4 at McGuire Nuclear Station Unit 2.
The information shown below is a field description for the reporting format included in this section of the report:
Item Number ID Number Iso / Dwg. Numbers Proc Insp Req.
Mat / Sch.
Diam. / Thick Cal Blocks Comments
=
ASME Section XI Tables IWB-2500-1 (Class 1), IWC-2500-1 (Class 2), IWF-2500-1 (Class 1 and Class 2 ), Augmented Requirements
=
Unique Identification Number
=
Location and/or Detail Drawings
=
Examination Procedures
=
Examination Technique - Magnetic Particle, Dye Penetrant, etc.
=
General Description of Material
=
Diameter/Thickness
=
Calibration Block Number General and/or Detail Description Outage 6/EOC-14 McGuire Unit 2 Section 4 Page 1 of 1 Revision 0 May 17, 2002
EOC 14 CATEGORY B-B, Pressure Reta in Vessels Other Than Reactor' Pressurizer ITEM NUMBER ID NUMBER DUKE ENERGYbdtRPORATION iining Welds INSERVICE INSPECTION PLAN MANAGEMENT Vessels Inservice Inspection Database Management System McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6 SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS Shell-to-Head Welds; Circumferential B02.011.001 2PZR-1 MCM 2201.01-15 NDE-620 UT CS 91.500 50337 Pressurizer Lower Head to Shell (Circumferential Circumferential NC MCM 2201.01-16 See Com 3.750 50236A Weld)
Class A Lower Head to "Depending upon the examiner's qualifications, Shell Procedure PDI-UT-6 may be used in lieu of procedure NDE-620."
Total B02.011 Items:
1
Longitudinal NC MCM 2201.01-16 See Corn 3.750 50236A 1' ADJACENT TO WELD 2PZR-1 Class A Lower Head to "Depending upon the examiner's qualifications, Shell Procedure PDI-UT-6 may be used in lieu of procedure NDE-620."
Total B02.012 Items:
1 Total B02 Items:
2 Plan Report Page 1 05/17/2002
EOC 14 CATEGORY B-D, Full Penetration Welds of Nozzels in Vessels
_Steam Generators (Primary Side)
ITEM NUMBER ID NUMBER DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 Plan Report Page 2 05/17/2002 Inservice Inspection Plan for Interval 2 Outage 6 SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIAiTHK CAL BLOCKS COMMENTS Nozzle Inside Radius Section ****
B03.140.007 2SGD-INLET MCM 2201.01-0216 NDE-680 UT CS 0.000 5131617 STEAM GENERATOR 2D PRIMARY INLET Circumferential NC MCM 2201.01-0207 6.500 NOZZLE RADIUSED SECTION. REFERENCE Class A 2MNS-063 B03.140.008 2SGD-OUTLET MCM 2201.01-0216 NDE-680 UT CS 0.000 5131617 STEAM GENERATOR 2D PRIMARY OUTLET Circumferential NC MCM 2201.01-0207 6.500 NOZZLE RADIUSED SECTION. REFERENCE Class A 2MNS-063 Total B03.140 Items:
Total B03 Items:
2 2
EOC 14 CATEGORY B-F, Pressure Retaining Dissimilar Metal Welds MReactor Vessel ITEM NUMBER ID NUMBER SYS ISO/DWG NUMB DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6 3ERS PROC INSP REQ MAT/SCH DIAITHK CAL BLOCKS NPS 4 or larger; Nozzle-to-Safe End Butt Welds B05.010.001B 2RPV-W11-SE MCM 2201.01-18/3 NDE-35 PT SS-CS 27.500 RV INLET NOZZLE TO SAFE END 67 DEG.
Circumferential NC MCM 2201.01-0009 2.281 TO BE DONE WITH B05.130.004B Class A RV INLET NOZZLE to Dissimilar SAFE END B05.010.002B 2RPV-W12-SE MCM 2201.01-18/6 NDE-35 PT SS-CS 27.500 RV INLET NOZZLE TO SAFE END 113 DEG.
Circumferential NC MCM 2201.01-0009 2.281 TO BE DONE WITH B05.130.008B Class A RV INLET NOZZLE to Dissimilar SAFE END B05.010.003B 2RPV-W1 3-SE MCM 2201.01-18/9 NDE-35 PT SS-CS 27.500 RV INLET NOZZLE TO SAFE END 247 DEG.
Circumferential NC MCM 2201.01-0009 2.281 TO BE DONE WITH B05.130.012B Class A RV INLET NOZZLE to Dissimilar SAFE END B05.010.004B 2RPV-W14-SE MCM 2201.01-18/12 NDE-35 PT SS-CS 27.500 RV INLET NOZZLE TO SAFE END 293 DEG.
Circumferential NC MCM 2201.01-0009 2.281 TO BE DONE WITH B05.130.016B Class A RV INLET NOZZLE to Dissimilar SAFE END Total B05.010 Items:
4 Plan Report Page 3 05/17/2002 COMMENTS
EOC 14 CATEGORY B-F, Pressure Retaining Dissimilar Metal Welds Steam Generator DUKE ENERGY C6RPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIAfTHK CAL BLOCKS
B05.070.001 2SGA-INLET-W5SE NDE-930 UT SS-CS 31.000 5149697 SG2A INLET NOZZLE SAFE END.
Circumferential NC MCM 2201.01-0207 2.500 5158172 TO BE DONE WITH B09.011.043. REFERENCE Class A Term end MCM 2201.01-0194 SG2A Inlet to 2MNS-064 Dissimilar Safe end B05.070.001 A 2SGA-INLET-W5SE NDE-35 PT SS-CS 31.000 SG2A INLET NOZZLE SAFE END Circumferential NC MCM 2201.01-0207 2.500 TO BE DONE WITH B09.011.43A. REFERENCE Class A Term end MCM 2201.01-0194 SG2A Inlet to 2MNS-064 Dissimilar Safe end B05.070.002 2SGA-OUTLET-W6SE NDE-930 UT SS-CS 31.000 5149697 SG2A OUTLET NOZZLE SAFE END.
Circumferential NC MCM 2201.01-0207 2.500 5158172 TO BE DONE WITH B09.011.044. REFERENCE Class A Term end MCM 2201.01-0194 SG2A Outlet to 2MNS-064 Dissimilar Safe end B05.070.002A 2SGA-OUTLET-W6SE NDE-35 PT SS-CS 31.000 SG2A OUTLET NOZZLE SAFE END.
Circumferential NC MCM 2201.01-0207 2.500 TO BE DONE WITH B09.011.44A. REFERENCE Class A Term end MCM 2201.01-0194 SG2A Outlet to 2MNS-064 Dissimilar Safe end B05.070.007 2SGD-INLET-W5SE NDE-930 UT SS-CS 31.000 5149697 SG2D INLET NOZZLE SAFE END Circumferential NC MCM 2201.01-0207 2.500 5158172 TO BE DONE WITH B09.011.049. REFERENCE Class A Term end MCM 2201.01-0194 SG2D Inlet to 2MNS-064 Dissimilar Safe end B05.070.007A 2SGD-INLET-W5SE NDE-35 PT SS-CS 31.000 SG2D INLET NOZZLE SAFE END Circumferential NC MCM 2201.01-0207 2.500 TO BE DONE WITH B09.011.049A. REFERENCE Class A Term end MCM 2201.01-0194 SG2D Inlet to 2MNS-064 Dissimilar Safe end B05.070.008 2SGD-OUTLET-W6SE NDE-930 UT SS-CS 31.000 5149697 SG2D OUTLET NOZZLE SAFE END Circumferential NC MCM 2201.01-0207 2.500 5158172 TO BE DONE WITH B09.011.050. REFERENCE Class A Term end MCM 2201.01-0194 SG2D Outlet to 2MNS-064 Dissimilar Safe end B05.070.008A 2SGD-OUTLET-W6SE NDE-35 PT SS-CS 31.000 SG2D OUTLET NOZZLE SAFE END Circumferential NC MCM 2201.01-0207 2.500 TO BE DONE WITH B09.011.050A. REFERENCE Class A Term end MCM 2201.01-0194 SG2D Outlet to 2MNS-064 Dissimilar Safe end Total B05.070 Items:
8 COMMENTS Plan Report Page 4 05/17/2002
EOC 14 CATEGORY B-F, Pressure Retaininq Dissimilar Metal Welds ITEM NUMBER ID NUMBER SYS I
-DUKE ENERGY 6O6RPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6 SO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS NPS 4 or Larger; Dissimilar Metal Butt Welds B05.130.004B 2NC2F-1-8 NDE-35 PT SS 27.500 TO BE DONE WITH B05.010.001B Circumferential NC MCM 2201.01-18/3 2.281 Class A MCM 2201.01-0009 Elbow to Dissimilar SAFE END B05.130.008B 2NC2F-2-8 NDE-35 PT SS 27.500 TO BE DONE WITH B05.010.002B Circumferential NC MCM 2201.01-18/6 2.300 Class A MCM 2201.01-09 Elbow to Dissimilar SAFE END B05.130.012B 2NC2F-3-8 NDE-35 PT SS 27.500 TO BE DONE WITH B05.010.003B Circumferential NC MCM 2201.01-18/9 2.281 Class A MCM 2201.01-09 Elbow to Dissimilar SAFE END B05.130.016B 2NC2F-4-8 NDE-35 PT SS 27.500 TO BE DONE WITH B05.010.004B Circumferential NC MCM 2201.01-18/12 2.300 Class A MCM 2201.01-09 Elbow to Dissimilar SAFE END Total B05.130 Items:
4 Total B05 Items:
16 Plan Report Page 5 05/1712002 COMMENTS
EOC 14 CATEGORY B-G-1, Pressure Retaining Bolting, Greater than 2" In Diameter WReactor Vessel DUKE ENERGY 66RPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA'THK CAL BLOCKS COMMENTS Closure Head Nuts B06.010.036 2RPV-664-32-36 MCM 2201.01-21 NDE-25 MT CS 10.540 REACTOR VESSEL CLOSURE HEAD NUTS NC RDM 30738-1544 1.770 Class A B06.010.037 2RPV-664-32-37 MCM 2201.01-21 NDE-25 MT CS 10.540 REACTOR VESSEL CLOSURE HEAD NUTS NC RDM 30738-1544 1.770 Class A B06.010.038 2RPV-664-32-38 MCM 2201.01-21 NDE-25 MT CS 10.540 REACTOR VESSEL CLOSURE HEAD NUTS NC RDM 30738-1544 1.770 Class A B06.010.039 2RPV-664-32-39 MCM 2201.01-21 NDE-25 MT CS 10.540 REACTOR VESSEL CLOSURE HEAD NUTS NC RDM 30738-1544 1.770 Class A B06.010.040 2RPV-664-32-40 MCM 2201.01-21 NDE-25 MT CS 10.540 REACTOR VESSEL CLOSURE HEAD NUTS NC RDM 30738-1544 1.770 Class A B06.010.041 2RPV-664-32-41 MCM 2201.01-21 NDE-25 MT CS 10.540 REACTOR VESSEL CLOSURE HEAD NUTS NC RDM 30738-1544 1.770 Class A B06.010.042 2RPV-664-32-42 MCM 2201.01-21 NDE-25 MT CS 10.540 REACTOR VESSEL CLOSURE HEAD NUTS NC RDM 30738-1544 1.770 Class A B06.010.043 2RPV-664-32-43 MCM 2201.01-21 NDE-25 MT CS 10.540 REACTOR VESSEL CLOSURE HEAD NUTS NC RDM 30738-1544 1.770 Class A Plan Report Page 6 05/17/2002
EOC 14 CATEGORY B-G-1, Pressure Retaining Bolting, Greater than 2" In Diameter MReactorVessel DUKE ENERGY C-6RPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS B06.010.044 2RPV-664-32-44 MCM 2201.01-21 NDE-25 MT CS 10.540 REACTOR VESSEL CLOSURE HEAD NUTS NC RDM 30738-1544 1.770 Class A B06.010.045 2RPV-664-32-45 MCM 2201.01-21 NDE-25 MT CS 10.540 REACTOR VESSEL CLOSURE HEAD NUTS NC RDM 30738-1544 1.770 Class A B06.010.046 2RPV-664-32-46 MCM 2201.01-21 NDE-25 MT CS 10.540 REACTOR VESSEL CLOSURE HEAD NUTS NC RDM 30738-1544 1.770 Class A B06.010.047 2RPV-664-32-47 MCM 2201.01-21 NDE-25 MT CS 10.540 REACTOR VESSEL CLOSURE HEAD NUTS NC RDM 30738-1544 1.770 Class A B06.010.048 2RPV-664-32-48 MCM 2201.01-21 NDE-25 MT CS 10.540 REACTOR VESSEL CLOSURE HEAD NUTS NC RDM 30738-1544 1.770 Class A B06.010.049 2RPV-664-32-49 MCM 2201.01-21 NDE-25 MT CS 10.540 REACTOR VESSEL CLOSURE HEAD NUTS NC RDM 30738-1544 1.770 Class A B06.010.050 2RPV-664-32-50 MCM 2201.01-21 NDE-25 MT CS 10.540 REACTOR VESSEL CLOSURE HEAD NUTS NC RDM 30738-1544 1.770 Class A B06.010.051 2RPV-664-32-51 MCM 2201.01-21 NDE-25 MT CS 10.540 REACTOR VESSEL CLOSURE HEAD NUTS NC RDM 30738-1544 1.770 Class A B06.010.052 2RPV-664-32-52 MCM 2201.01-21 NDE-25 MT CS 10.540 RFACTOR1E
\\/SEL Cl l
I ID* I-JAn niN IT-NC RDM 30738-1544 Class A
.in JJL)EL t'..LUOS %.f l..J IL I
L.R JU I Z5 1.770 Plan Report Page 7 05/17/2002
EOC 14 CATEGORY B-G-1, Pressure Re Bolting, Greater than 2" In Diam MReactor Vessel ITEM NUMBER ID NUMBER B06.010.053 2RPV-664-32-53 Class A Btaining neter DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Manaaement System
"....Plan Report McGuire 2 Page 8 Inservice Inspection Plan for Interval 2 Outage 6 05/17/2002 SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA-IHK CAL BLOCKS COMMENTS MCM 2201.01-21 NDE-25 MT CS 10.540 REACTOR VESSEL CLOSURE HEAD NUTS NC RDM 30738-1544 1.770 B06.010.054 2RPV-664-32-54 Class A MCM 2201.01-21 NC RDM 30738-1544 NDE-25 MT CS 10.540 REACTOR VESSEL CLOSURE HEAD NUTS 1.770 Total B06.010 Items:
19
EOC 14 CATEGORY B-G-l. Pressure Retaining Bolting, Greater than 2" In Diameter Reactor Vessel ITEM NUMBER ID NUMBER
- Closure Studs, when removed
- B06.030.036 2RPV-664-31-36 N
Class A SYS ISO/DWG NIIMF MUM 2201-U1-21 C
RDM 30738-1544 DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6 3ERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS See Com UT CS 7.000 64.560 50501 CLOSURE STUD USE PROCEDURE PDI-UT-5 BUO.U,,U.U,00
-0 3
lRPV-664-Ljl J Class A MUM 2201-01-21 NC RDM 30738-1544 NDE-25 MT CS 7.000 64.560 CLOSURE STUD 1306.u03.u*372RPV-6b4-31-3/
Class A MCM 2201-01-21 NC RDM 30738-1544 See Com UT CS 7.000 64.560 50501 CLOSURE STUD USE PROCEDURE PDI-UT-5 B06.030.037A 2RPV-664-31-37 MCM 2201-01-21 NDE-25 MT CS 7.000 CLOSURE STUD NC RDM 30738-1544 64.560 Class A B06.030.038 2RPV-664-31-38 MCM 2201-01-21 See Comr UT CS 7.000 50501 CLOSURE STUD NC RDM 30738-1544 64.560 USE PROCEDURE PDI-UT-5 Class A B06.030.038A 2RPV-664-31-38 MCM 2201-01-21 NDE-25 MT CS 7.000 CLOSURE STUD NC RDM 30738-1544 64.560 Class A B06.030.039 2RPV-664-31-39 MCM 2201-01-21 See Comr UT CS 7.000 50501 CLOSURE STUD NC RDM 30738-1544 64.560 USE PROCEDURE PDI-UT-5 Class A 106.030.039A 2RPV-664-31-39 MCM 2201-01-21 NDE-25 MT CS 7.000 CLOSURE STUD Class A Plan Report Page 9 05/17/2002 COMMENTS NC RDM 30738-1544 64.560 Jýý/
ýVv%.A 111VIVILD RAeKA nn^4
^4
^4
- Pnr, nqf) nl'ýaA ODDX/
aaA 01 13--
RA^RA^^^4
^4 QnA Wlf) M7 f3DD%/
LCA 134 11-7
-1
^1
EOC 14 CATEGORY B-G-1, Pressure Retaining Bolting, Greater than 2" In Diameter OReactor Vessel DUKE ENERGY'-ORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS B06.030.040 2RPV-664-31-40 MCM 2201-01-21 See Corn UT CS 7.000 50501 CLOSURE STUD NC RDM 30738-1544 64.560 USE PROCEDURE PDI-UT-5 Class A B06.030.040A 2RPV-664-31-40 MCM 2201-01-21 NDE-25 MT CS 7.000 CLOSURE STUD NC RDM 30738-1544 64.560 Class A B06.030.041 2RPV-664-31-41 MCM 2201-01-21 See Com UT CS 7.000 50501 CLOSURE STUD NC RDM 30738-1544 64.560 USE PROCEDURE PDI-UT-5 Class A B06.030.041 A 2RPV-664-31-41 MCM 2201-01-21 NDE-25 MT CS 7.000 CLOSURE STUD NC RDM 30738-1544 64.560 Class A B06.030.042 2RPV-664-31-42 MCM 2201-01-21 See Com UT CS 7.000 50501 CLOSURE STUD NC RDM 30738-1544 64.560 USE PROCEDURE PDI-UT-5 Class A B06.030.042A 2RPV-664-31-42 MCM 2201-01-21 NDE-25 MT CS 7.000 CLOSURE STUD NC RDM 30738-1544 64.560 Class A B06.030.043 2RPV-664-31-43 MCM 2201-01-21 See Com UT CS 7.000 50501 CLOSURE STUD NC RDM 30738-1544 64.560 USE PROCEDURE PDI-UT-5 Class A B06.030.043A 2RPV-664-31-43 MCM 2201-01-21 NDE-25 MT CS 7.000 CLOSURE STUD NC RDM 30738-1544 64.560 Class A B06.030.044 2RPV-664-31-44 MCM 2201-01-21 See Com UT CS 7.000 50501 CLOSURE STUD NC RDM 30738-1544 64.560 USE PROCEDURE PDI-UT-5 Class A Plan Report Page 10 05/17/2002
EOC 14 CATEGORY B-G-1, Pressure Retaining Bolting., Greater than 2" In Diameter Reactor Vessel DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS B06.030.044A 2RPV-664-31-44 MCM 2201-01-21 NDE-25 MT CS 7.000 CLOSURE STUD NC RDM 30738-1544 64.560 Class A B06.030.045 2RPV-664-31-45 MCM 2201-01-21 See Com UT CS 7.000 50501 CLOSURE STUD NC RDM 30738-1544 64.560 USE PROCEDURE PDI-UT-5 Class A B06.030.045A 2RPV-664-31-45 MCM 2201-01-21 NDE-25 MT CS 7.000 CLOSURE STUD NC RDM 30738-1544 64.560 Class A B06.030.046 2RPV-664-31-46 MCM 2201-01-21 See Com UT CS 7.000 50501 CLOSURE STUD NC RDM 30738-1544 64.560 USE PROCEDURE PDI-UT-5 Class A B06.030.046A 2RPV-664-31-46 MCM 2201-01-21 NDE-25 MT CS 7.000 CLOSURE STUD NC RDM 30738-1544 64.560 Class A B06.030.047 2RPV-664-31-47 MCM 2201-01-21 See Com UT CS 7.000 50501 CLOSURE STUD NC RDM 30738-1544 64.560 USE PROCEDURE PDI-UT-5 Class A B06.030.047A 2RPV-664-31-47 MCM 2201-01-21 NDE-25 MT CS 7.000 CLOSURE STUD NC RDM 30738-1544 64.560 Class A B06.030.048 2RPV-664-31-48 MCM 2201.01-21 See Com UT CS 7.000 50501 CLOSURE STUD NC RDM 30738-1544 64.560 USE PROCEDURE PDI-UT-5 Class A B06.030.048A 2RPV-664-31-48 MCM 2201.01-21 NDE-25 MT CS 7.000 CLOSURE STUD NC RDM30738-1544 64.560 Class A Plan Report Page 11 05/17/2002
EOC 14 CATEGORY B-G-1. Pressure Retaining Bolting, Greater than 2" In Diameter Reactor Vessel DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS B06.030.049 2RPV-664-31-49 MCM 2201.01-21 See Corn UT CS 7.000 50501 CLOSURE STUD NC RDM 30738-1544 64.560 USE PROCEDURE PDI-UT-5 Class A B06.030.049A 2RPV-664-31-49 MCM 2201.01-21 NDE-25 MT CS 7.000 CLOSURE STUD NC RDM 30738-1544 64.560 Class A B06.030.050 2RPV-664-31-50 MCM 2201.01-21 See Com UT CS 7.000 50501 CLOSURE STUD NC RDM 30738-1544 64.560 USE PROCEDURE PDI-UT-5 Class A B06.030.050A 2RPV-664-31-50 MCM 2201.01-21 NDE-25 MT CS 7.000 CLOSURE STUD NC RDM 30738-1544 64.560 Class A B06.030.051 2RPV-664-31-51 MCM 2201.01-21 See Com UT CS 7.000 50501 CLOSURE STUD NC RDM 30738-1544 64.560 USE PROCEDURE PDI-UT-5 Class A B06.030.051 A 2RPV-664-31-51 MCM 2201.01-21 NDE-25 MT CS 7.000 CLOSURE STUD NC RDM 30738-1544 64.560 Class A B06.030.052 2RPV-664-31-52 MCM 2201.01-21 See Com UT CS 7.000 50501 CLOSURE STUD NC RDM 30738-1544 64.560 USE PROCEDURE PDI-UT-5 Class A B06.030.052A 2RPV-664-31-52 MCM 2201.01-21 NDE-25 MT CS 7.000 CLOSURE STUD NC RDM 30738-1544 64.560 Class A B06.030.053 2RPV-664-31-53 MCM 2201.01-21 See Corn UT CS 7.000 50501 CLOSURE STUD NC RDM 30738-1544 64.560 USE PROCEDURE PDI-UT-5 Class A Plan Report Page 12 05/17/2002
EOC 14 CATEGORY B-G-1, Pressure Re Bolting, Greater than 2" In Diam Neactor Vessel ITEM NUMBER ID NUMBER B06.030.053A 2RPV-664-31-53
.taining ieter DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6 SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS MCM 2201.01-21 NDE-25 MT CS 7.000 CLOSURE STUD NC RDM 30738-1544 64.560 Class A B06.030.054 2RPV-664-31-54 MCM 2201.01-21 See Corn UT CS 7.000 50501 CLOSURE STUD NC RDM 30738-1544 64.560 USE PROCEDURE PDI-UT-5 Class A B06.030.054A 2RPV-664-31-54 MCM 2201.01-21 NDE-25 MT CS 7.000 CLOSURE STUD NC RDM 30738-1544 64.560 Class A Total B06.030 Items:
38 Plan Report Page 13 05/17/2002
EOC 14 CATEGORY B-G-1, Pressure Retaining Bolting, Greater than 2" In Diameter MReactorVessel ITEM NI IMRFR ID NUMBER SYS ISO/DWG NUMBE DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT InserviceInspection Database Management System McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6
-RS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS Closure Washers, Bushings B06.050.036 2RPV-664-33-36 MCM 2201.01-21 QAL-13 VT-1 CS 10.560 CLOSURE WASHERS NC RDM 30738-1544 0.000 Class A B06.050.037 2RPV-664-33-37 MCM 2201.01-21 QAL-13 VT-1 CS 10.560 CLOSURE WASHERS NC RDM 30738-1544 0.000 Class A B06.050.038 2RPV-664-33-38 MCM 2201.01-21 QAL-13 VT-1 CS 10.560 CLOSURE WASHERS NC RDM 30738-1544 0.000 Class A B06.050.039 2RPV-664-33-39 MCM 2201.01-21 QAL-13 VT-1 CS 10.560 CLOSURE WASHERS NC RDM 30738-1544 0.000 Class A B06.050.040 2RPV-664-33-40 MCM 2201.01-21 QAL-13 VT-1 CS 10.560 CLOSURE WASHERS NC RDM 30738-1544 0.000 Class A B06.050.041 2RPV-664-33-41 MCM 2201.01-21 QAL-13 VT-1 CS 10.560 CLOSURE WASHERS NC RDM 30738-1544 0.000 Class A B06.050.042 2RPV-664-33-42 MCM 2201.01-21 QAL-13 VT-1 CS 10.560 CLOSURE WASHERS NC RDM 30738-1544 0.000 Class A B06.050.043 2RPV-664-33-43 MCM 2201.01-21 QAL-13 VT-1 CS 10.560 CLOSURE WASHERS NC RDM 30738-1544 0.000 Class A Plan Report Page 14 05/17/2002 COMMENTS II LI
- vj IM I lV..
EOC 14 CATEGORY B-G-1, Pressure Retaining Bolting, Greater than 2" In Diameter WReactor Vessel DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS B06.050.044 2RPV-664-33-44 MCM 2201.01-21 QAL-13 VT-1 CS 10.560 CLOSURE WASHERS NC RDM 30738-1544 0.000 Class A B06.050.045 2RPV-664-33-45 MCM 2201.01-21 QAL-13 VT-1 CS 10.560 CLOSURE WASHERS NC RDM 30738-1544 0.000 Class A B06.050.046 2RPV-664-33-46 MCM 2201.01-21 QAL-13 VT-1 CS 10.560 CLOSURE WASHERS NC RDM 30738-1544 0.000 Class A B06.050.047 2RPV-664-33-47 MCM 2201.01-21 QAL-13 VT-1 CS 10.560 CLOSURE WASHERS NC RDM 30738-1544 0.000 Class A B06.050.048 2RPV-664-33-48 MCM 2201.01-21 QAL-13 VT-1 CS 10.560 CLOSURE WASHERS NC RDM 30738-1544 0.000 Class A B06.050.049 2RPV-664-33-49 MCM 2201.01-21 QAL-13 VT-1 CS 10.560 CLOSURE WASHERS NC RDM 30738-1544 0.000 Class A B06.050.050 2RPV-664-33-50 MCM 2201.01-21 QAL-13 VT-1 CS 10.560 CLOSURE WASHERS NC RDM 30738-1544 0.000 Class A B06.050.051 2RPV-664-33-51 MCM 2201.01-21 QAL-13 VT-1 CS 10.560 CLOSURE WASHERS NC RDM 30738-1544 0.000 Class A B06.050.052 2RPV-664-33-52 MCM 2201.01-21 QAL-13 VT-1 CS 10.560 CLOSURE WASHERS NC RDM 30738-1544 0.000 Class A Plan Report Page 15 05/17/2002
EOC 14 CATEGORY B-G-1, Pressure Re Bolting, Greater than 2" In Diarn Reactor Vessel ITEM NUMBER ID NUMBER B06.050.053 2RPV-664-33-53 DUKE ENERGY C&RPORATION 3taining INSERVICE INSPECTION PLAN MANAGEMENT ieter Inservice Inspection Database Management System McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6 SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS MCM 2201.01-21 QAL-13 VT-1 CS 10.560 CLOSURE WASHERS NC RDM 30738-1544 0.000 Plan Report Page 16 05/17/2002 Class A B06.050.054 2RPV-664-33-54 MCM 2201.01-21 QAL-13 VT-1 CS 10.560 CLOSURE WASHERS NC RDM 30738-1544 0.000 Class A Total B06.050 Items:
19
EOC 14 CATEGORY B-G-1, Pressure Retaining Bolting, Greater than 2" In Diameter OSteamGenerators ITEM NUMBER ID NUMBER SYS ISO /DWG NUMBE Inservice Inspection Plan for Interval 2 Outage 6
-RS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS Bolts and Studs ****
B06.090.003 2SGB-MW-YI-X2 MCM 2201.01-0127 NDE-947 UT CS 26.625 7C015 2B S/G PRIMARY INLET MANWAY STUDS (20).
NC MCM 2201.01-0172 2.500 Y1-X2 QUADRANT. REFERENCE 2MNS-065 Class A B06.090.004 2SGB-MW-X2-Y2 MCM 2201.01-0127 NDE-947 UT CS 26.625 7C015 2B S/G PRIMARY OUTLET MANWAY STUDS (20).
NC MCM 2201.01-0172 2.500 X2-Y2 QUADRANT. REFERENCE 2MNS-065 Class A B06.090.005 2SGC-MW-Y1-X1 MCM 2201.01-0126 NDE-947 UT CS 26.625 7C015 2C S/G PRIMARY INLET MANWAY STUDS (20).
NC MCM 2201.01-0172 2.500 Y1-X1 QUADRANT. REFERENCE 2MNS-065 Class A B06.090.006 2SGC-MW-X1-Y2 MCM 2201.01-0126 NDE-947 UT CS 26.625 7C015 2C S/G PRIMARY OUTLET MANWAY STUDS (20).
NC MCM 2201.01-0172 2.500 X1-Y2 QUADRANT. REFERENCE 2MNS-065 Class A Total B06.090 Items:
4 DUKE ENERGY CRPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 Plan Report Page 17 05/17/2002 COMMENTS
EOC 14 CATEGORY B-G-1, Pressure Retaining Bolting. Greater than 2" In Diameter Steam Generat ors ITEM NUMBER ID NUMBER SYS ISO DUKE ENERGYOCORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6
/DWG NUMBERS PROC INSP REQ MAT/SCH DIAITHK CAL BLOCKS
- Flange Surface, when connection dissassembled....
B06.100.003 2SGB-MW-Y1-X2 MCM 2201.01-0194 QAL-13 VT-1 CS 0.000 2B S/G PRIMARY INLET MANWAY FLANGE.
NC MCM 2201.01-0127 0.000 Y1-X2 QUADRANT. REFERENCE 2MNS-065 Class A B06.100.004 2SGB-MW-X2-Y2 MCM 2201.01-0194 QAL-13 VT-1 CS 0.000 2B S/G PRIMARY OUTLET MANWAY FLANGE.
NC MCM 2201.01-0127 0.000 X2-Y2 QUADRANT. REFERENCE 2MNS-065 Class A B06.100.005 2SGC-MW-Y1-X1 MCM 2201.01-0194 QAL-13 VT-1 CS 0.000 2C S/G PRIMARY INLET MANWAY FLANGE.
NC MCM 2201.01-0126 0.000 Y1-X1 QUADRANT. REFERENCE 2MNS-065 Class A B06.100.006 2SGC-MW-X1-Y2 MCM 2201.01-0194 QAL-13 VT-1 CS 0.000 2C S/G PRIMARY OUTLET MANWAY FLANGE.
NC MCM 2201.01-0126 0.000 X1-Y2 QUADRANT. REFERENCE 2MNS-065 Class A Total B06.1 00 Items:
4 Plan Report Page 18 05/17/2002 COMMENTS
EOC 14 CATEGORY B-G-1, Pressure Retaining Bolting, Greater than 2" In Diameter Steam Generators ITEM NUMBER ID NUMBER SYS ISOA/DWG NUMBE Inservice Inspection Plan for Interval 2 Outage 6
-RS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS
- Nuts, Bushings, and Washers ****
B06.110.003 2SGB-MW-YI-X2 MCM 2201.01-0127 QAL-13 VT-1 CS 0.000 2B S/G PRIMARY INLET MANWAY NUTS (20).
NC MCM 2201.01-0172 2.500 Y1-X2 QUADRANT. REFERENCE 2MNS-065 Class A B06.110.004 2SGB-MW-X2-Y2 MCM 2201.01-0127 QAL-13 VT-I CS 0.000 2B S/G PRIMARY OUTLET MANWAY NUTS (20).
NC MCM 2201.01-0172 2.500 X2-Y2 QUADRANT. REFERENCE 2MNS-065 Class A B06.110.005 2SGC-MW-Y1-X1 MCM 2201.01-0126 QAL-13 VT-1 CS 0.000 2C S/G PRIMARY INLET MANWAY NUTS (20).
NC MCM 2201.01-0172 2.500 Y1-X1 QUADRANT. REFERENCE 2MNS-065 Class A 806.110.006 2SGC-MW-X1-Y2 MCM 2201.01-0126 QAL-13 VT-1 CS 0.000 2C S/G PRIMARY OUTLET MANWAY NUTS (20).
NC MCM 2201.01-0172 2.500 X1-Y2 QUADRANT. REFERENCE 2MNS-065 Class A Total B06.110 Items:
4 DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 Plan Report Page 19 05/17/2002 COMMENTS
EOC 14 CATEGORY B-G-1, Pressure Retaining Bolting, Greater than 2" In Diameter ITEM NUMBER ID NUMBER SYS DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6 ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS Bolts and Studs ****
B06.180.004 2RCP-2D-F MCM 1201.01-120 See Com UT CS 4.370 50502 24 BOLTS LOCATED IN 2D REACTOR COOLANT NC MC 2553.1.0 30.500 PUMP MAIN FLANGE PC.10, USE PROCEDURE Class A PDI-UT-5 Total B06.180 Items:
1 Total B06 Items:
89 Plan Report Page 20 05/17/2002
EOC 14 CATEGORY B-G-2, Pressure Retaining Bolting, 2" And Less In Diameter ITEM NUMBER ID NUMBER SYS ISOA DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6
/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS Bolts, Studs, and Nuts B07.050.102 2NV275-FL1 MCFI-2NV275 QAL-13 VT-1 SS 1.500 FLANGE BOLTING NV 0.000 Class A B07.050.103 2NV282-FL1 MCFI-2NV282 QAL-13 VT-1 SS 1.500 FLANGE BOLTING NV 0.000 Class A Total B07.050 Items:
2 Plan Report Page 21 05/17/2002
EOC 14 CATEGORY B-G-2, Pressure Retaining Bolting, 2" And Less In Diameter alves ITEM NUMBER ID NUMBER SY DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 Plan Report Page 22 05/17/2002 Inservice Inspection Plan for Interval 2 Outage 6 WS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS
- Bolts, Studs, and Nuts B07.070.001A2NC-1 MCFI-2NC53 QAL-13 VT-1 SS 0.000 6" VALVE, 1" STUDS (8), 1" NUTS (8). INSPECT NC MC 2553-2.0 0.000 ONLY ONE VALVE IN THIS GROUP PER Class A MCM 1205.09-001-01 INTERVAL B07.070.009A2N1-65B MCFI-2NI118 QAL-13 VT-1 SS 0.075 10" VALVE. INSPECT ONLY ONE VALVE IN THIS NI MC 2562-2.0 0.000 GROUP PER INTERVAL Class A MCM 1205.00-0012 B07.070.012A 2NV-21A MCFI-2NV102 QAL-13 VT-1 SS 0.000 2" VALVE. INSPECT ONLY ONE VALVE IN THIS NV MC 2554-1.2 0.000 GROUP PER INTERVAL Class A MCM 1205.06-136/1 Total B07.070 Items:
3 Total B07 Items:
5
EOC 14 CATEGORY B-H, Integral Attachments for Vessels Pressurizer ITEM NUMBER ID NUMBER DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6 SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS
- Integrally Welded Attachments ****
B08.020.001 2PZR-SKIRT MCM 2201.01-16 NDE-25 MT CS 87.000 PZR SUPP. SKIRT TO LOWER HEAD NC EDSK-379441 B 1.500 Class A SKIRT to LOWER HEAD B08.020.001A 2PZR-SKIRT MCM 2201.01-16 NDE-952 UT CS 87.000 50237B PZR SUPP. SKIRT TO LOWER HEAD. AN NC EDSK-379441B 1.500 ULTRASONIC EXAMINATION SHALL BE Class A SKIRT to PERFORMED TO OBTAIN ADDITIONAL LOWER HEAD COVERAGE ON ID. REFERENCE REQUEST FOR RELIEF SERIAL NO.00-001 Total B08.020 Items:
2 Total B08 Items:
2 Plan Report Page 23 05/1712002 I
I
EOC 14 CATEGORY B-J, Pressure Retaining Welds In Piping a
MNPS 4 r Larger ITEM NUIMBER ID NUMBER SYS ISO/DWG NUMB DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6 3ERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS
- Circumferential Welds B09.011.009 2NCW-3673-1 BWNC-2(B LOOP)
NDE-610 UT SS 27.500 50214 Circumferential NC MCM 2201.01-18/6 2.000 Class A Pipe PC.1 Loop 2 to Elbow PC.A Loop 2 B09.011.009A 2NCW-3673-1 BWNC-2(B LOOP)
NDE-35 PT SS 27.500 Circumferential NC MCM 2201.01-18/6 2.000 Class A Pipe PC.1 Loop 2 to Elbow PC.A Loop 2 B09.011.011 2NC2FW2-1 MCFI-2NC2 NDE-600 UT SS 14.000 50207 Circumferential NC MGM 2201.01-118 160 1.406 Class A Stress weld Pipe to Pipe B09.011.011A 2NC2FW2-1 MCFI-2NC2 NDE-35 PT SS 14.000 Circumferential NC MCM 2201.01-118 160 1.406 Class A Stress weld Pipe to Pipe B09.011.012 2NC2FW22-6 MCFI-2NC22 NDE-600 UT SS 10.000 50209 Circumferential NC 140 1.000 Class A Stress weld Elbow to Nozzle B09.011.012A 2NC2FW22-6 MCFI-2NC22 NDE-35 PT SS 10.000 Circumferential NC 140 1.000 Class A Stress weld Elbow to Nozzle B09.011.013 2NC2FW22-9 MCFI-2NC22 NDE-600 UT SS 10.000 50209 Circumferential NC 140 1.000 Class A Stress weld Pipe to Nozzle B09.011.013A 2NC2FW22-9 MCFI-2NC22 NDE-35 PT SS 10.000 Circumferential Class A Stress weld NC 140 Pipe to Nozzle 1.000 Plan Report Page 24 05/17/2002
EOC 14 CATEGORY B-J, Pressure Retai Piping NPS 4 or Larger ITEM NUMBER ID NUMBER B09.011.017 2NC2FW13-8 Circumferential Class A Stress weld ining Welds In DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6 SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS MCFI-2NC13 NDE-600 UT SS 6.000 50211 NC 160 0.719 Elbow to Reducer B09.011.017A 2NC2FW13-8 MCFI-2NC13 NDE-35 PT SS 6.000 Circumferential NC 160 0.719 Class A Stress weld Elbow to Reducer B09.011.018 2NC2FW16-6 MCFI-2NC16 NDE-600 UT SS 6.000 50211 Circumferential NC 160 0.719 Class A Stress weld Elbow to Nozzle B09.011.018A 2NC2FW1 6-6 MCFI-2NC16 NDE-35 PT SS 6.000 Circumferential NC 160 0.719 Class A Stress weld Elbow to Nozzle B09.011.025 2NC2FW53-12 MCFI-2NC53 NDE-600 UT SS 6.000 50211 PRESSURIZER SAFETY LINE SE Circumferential NC 160 0.719 UT FROM ELBOW SIDE Class A Term end Elbow to SAFE END B09.011.025A 2NC2FW53-12 MCFI-2NC53 NDE-35 PT SS 6.000 PRESSURIZER SAFETY LINE SE Circumferential NC 160 0.719 Class A Term end SAFE END to Elbow B09.011.025B 2NC2FW53-12 MCFI-2NC53 NDE-600 UT SS 8.000 50250 PRESSURIZER SAFETY LINE SE Circumferential NC 1.200 UT FROM SE SIDE Class A Term end Elbow B09.011.026 2NC2FW53-13 MCFI-2NC53 NDE-600 UT SS 6.000 50211 PRESSURIZER SAFETY LINE SE Circumferential NC 160 0.719 UT FROM ELBOW SIDE Class A Term end Elbow to SAFE END B09.011.026A 2NC2FW53-13 MCFI-2NC53 NDE-35 PT SS 6.000 PRESSURIZER SAFETY LINE SE Circumferential Class A Term end NC 160 0.719 Elbow SAFE END Plan Report Page 25 05/17/2002
EOC 14 CATEGORY B-J, Pressure Retaining Welds In Piping MNPS 4 or Larger DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 E
Inservice Inspection Plan for Interval 2 Outage 6 U51, 1,2uuL ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS B09.011.026B 2NC2FW53-13 MCFI-2NC53 NDE-600 UT SS 8.000 50250 PRESSURIZER SAFETY LINE SE Circumferential NC 1.200 UT FROM SE SIDE Class A Term end SAFE END to Elbow B09.011.028 2NC2FW53-17 MCFI-2NC53 NDE-600 UT SS 6.000 50211 Circumferential NC 160 0.719 Class A Stress weld Elbow to Pipe B09.011.028A 2NC2FW53-17 MCFI-2NC53 NDE-35 PT SS 6.000 Circumferential NC 160 0.719 Class A Stress weld Elbow to Pipe B09.011.040 2NC2FW61-1 MCFI-2NC61 NDE-600 UT SS 6.000 50211 PRESSURIZER RELIEF LINE SE Circumferential NC 160 0.719 UT FROM ELBOW SIDE Class A Term end Elbow to SAFE END B09.011.040A 2NC2FW61 -1 MCFI-2NC61 NDE-35 PT SS 6.000 PRESURIZER RELIEF LINE SE Circumferential NC 160 0.719 Class A Term end SAFE END to Elbow B09.011.040B 2NC2FW61-1 MCFI-2NC61 NDE-600 UT SS 8.000 50250 PRESSURIZER RELIEF LINE SE Circumferential NC 1.200 UT FROM SE SIDE Class A Term end Elbow B09.011.041 2NC2FW13-19 MCFI-2NC13 NDE-600 UT SS 4.000 50275 Circumferential NC 160 0.531 Class A Stress weld Reducer to Pipe B09.011.041A 2NC2FW13-19 MCFI-2NC13 NDE-35 PT SS 4.000 Circumferential NC 160 0.531 Class A Stress weld Reducer to Pipe B09.011.042 2NC2FW13-1 MCFI-2NC13 NDE-600 UT SS 4.000 50275 PRESSURIZER SPRAY LINE SE Circumferential Class A Term end / Stress weld NC 160 Elbow to Safe end 0.531 UT FROM ELBOW SIDE Plan Report Page 26 nrI 14 o I wt,'
EOC 14 CATEGORY B-J, Pressure Retaining Welds In Piping UNPS 4 r Larger DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS B09.011.042A 2NC2FW13-1 MCFI-2NC13 NDE-35 PT SS 4.000 PRESSURIZER SPRAY LINE SE Circumferential NC 160 0.531 Class A Term end / Stress weld SAFE END to Elbow B09.011.042B 2NC2FW1 3-1 MCFI-2NC13 NDE-600 UT SS 6.000 50340 PRESSURIZER SPRAY LINE SE Circumferential NC 1.250 UT FROM SE SIDE Class A Term end / Stress weld SAFE END to Elbow B09.011.043 2NC2F-1-2 MC 2676-4 NDE-610 UT SS 31.000 50214 UT FROM ELBOW SIDE NDE-610, UT FROM SE Circumferential NC MCM 2201.01-18/1 NDE-600 2.500 NDE-600 Class A MC 1676-01.09 SG2A Inlet Safe-end to TO BE DONE WITH B05.070.001. THIS WELD Dissimilar Elbow WAS LISTED AS B05.130.002 PRIOR TO SGR.
REFERENCE 2MNS-064 B09.011.043A 2NC2F-1 -2 MC 2676-4 NDE-35 PT SS 31.000 TO BE DONE WITH B05.070.001 A. THIS WELD Circumferential NC MCM 2201.01-18/1 2.500 WAS LISTED AS B05.130.002A PRIOR TO SGR.
Class A MC 1676-01.09 SG2A Inlet Safe -end to REFERENCE 2MNS-064 Dissimilar Elbow B09.011.044 2NC2F-1-3 MC 2676-4 NDE-610 UT SS 31.000 50214 UT FROM ELBOW SIDE NDE-610, UT FROM SE Circumferential NC MCM 2201.01-18/2 NDE-600 2.500 NDE-600 Class A MC 1676-01.09 SG2A Outlet Safe-end to TO BE DONE WITH B05.070.002. THIS WELD Dissimilar Elbow WAS LISTED AS B05.130.003 PRIOR TO SGR.
REFERENCE 2MNS-064 809.011.044A 2NC2F-1-3 MC 2676-4 NDE-35 PT SS 31.000 TO BE DONE WITH B05.070.002A. THIS WELD Circumferential NC MCM 2201.01-18/2 2.500 WAS LISTED AS B05.130.003A PRIOR TO SGR.
Class A MC 1676-01.09 SG2A Outlet Safe-end to REFERENCE 2MNS-064 Dissimilar Elbow B09.011.049 2NC2F-4-2 MC 2676-4 NDE-610 UT SS 31.000 50214 UT FROM ELBOW SIDE NDE-610, UT FROM SE Circumferential NC MCM 2201.01-18/10 NDE-600 2.500 NDE-600 Class A MC 1676-01.09 SG2D Inlet Safe-end to TO BE DONE WITH B05.070.007. THIS WELD Dissimilar Elbow WAS LISTED AS B05.130.014 PRIOR TO SGR.
REFERENCE 2MNS-064 B09.011.049A 2NC2F-4-2 MC 2676-4 NDE-35 PT SS 31.000 TO BE DONE WITH B05.070.007A. THIS WELD Circumferential Class A Dissimilar NC MCM 2201.01-18/10 MC 1676-01.09 2.500 SG2D Inlet Safe-end to Elbow WAS LISTED AS B05.130.014A PRIOR TO SGR.
REFERENCE 2MNS-064 Plan Report Page 27 05/17/2002
EOC 14 CATEGORY B-J, Pressure Retaining Welds In Piping MNP 4
r Larger DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS B09.011.050 2NC2F-4-3 MC 2676-4 NDE-610 UT SS 31.000 50214 UT FROM ELBOW SIDE NDE-610, UT FROM SE Circumferential NC MCM 2201.01-18/11 NDE-600 2.500 NDE-600 Class A MC 1676-01.09 SG2D Outlet Safe-end to TO BE DONE WITH B05.070.008. THIS WELD Dissimilar Elbow WAS LISTED AS B05.130.015 PRIOR TO SGR.
REFERENCE 2MNS-064 B09.011.050A 2NC2F-4-3 MC 2676-4 NDE-35 PT SS 31.000 TO BE DONE WITH B05.070.008A. THIS WELD Circumferential NC MCM 2201.01-18/11 2.500 WAS LISTED AS B05.130.015A PRIOR TO SGR.
Class A MC 1676-01.09 SG2D Outlet Safe-end to REFERENCE 2MNS-064 Dissimilar Elbow B09.011.102 2ND2F-4 MCFI-2ND1 NDE-600 UT SS 14.000 50213 Circumferential ND 140 1.250 Class A Elbow to Elbow B09.011.102A 2ND2F-4 MCFI-2ND1 NDE-35 PT SS 14.000 Circumferential ND 140 1.250 Class A Elbow to Elbow B09.011.103 2ND2F-6 MCFI-2ND1 NDE-600 UT SS 14.000 50213 Circumferential ND 140 1.250 Class A Pipe to Elbow B09.011.103A 2ND2F-6 MCFI-2ND1 NDE-35 PT SS 14.000 Circumferential ND 140 1.250 Class A Pipe to Elbow B09.011.169 2NI2F871 MCFI-2NI19 NDE-600 UT SS 6.000 50211 Circumferential NI 160 0.719 Class A Elbow to Pipe B09.011.169A 2NI2F871 MCFI-2NI19 NDE-35 PT SS 6.000 Circumferential Class A NI 160 Elbow to Pipe 0.719 Plan Report Page 28 05/17/2002
EOC 14 CATEGORY B-J, Pressure Retaining Welds In Piping MNPS 4 r Larger DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6 Plan Report Page 29 05/17/2002 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS B09.011.170 2NI2FW85-14 MCFI-2N185 NDE-600 UT SS 8.000 50210 Circumferential NI 160 0.906 Class A Elbow to Pipe B09.011.170A 2NI2FW85-14 MCFI-2N185 NDE-35 PT SS 8.000 Circumferential NI 160 0.906 Class A Elbow to Pipe B09.011.173 2N12FW85-1 MCFI-2NI85 NDE-600 UT SS 8.000 50210 Circumferential NI 160 0.906 Class A Pipe to Elbow B09.011.173A 2Nl2FW85-1 MCFI-2N185 NDE-35 PT SS 8.000 Circumferential NI 160 0.906 Class A Pipe to Elbow B09.011.174 2N12FW85-6 MCFI-2NI85 NDE-600 UT SS 8.000 50210 Circumferential NI 160 0.906 Class A Pipe to Elbow B09.011.174A 2N12FW85-6 MCFI-2NI85 NDE-35 PT SS 8.000 Circumferential NI 160 0.906 Class A Pipe to Elbow B09.011.175 2NI2FW85-13 MCFI-2NI85 NDE-600 UT SS 8.000 50210 Circumferential NI 160 0.906 Class A Pipe to Reducer B09.011.175A 2NI2FW85-13 MCFI-2N185 NDE-35 PT SS 8.000 Circumferential NI 160 0.906 Class A Pipe to Reducer Total B09.011 Items:
50
EOC 14 CATEGORY B-J, Pressure Reta Pipingi ILess Than NPS 4 ITEM NUMBER ID NUMBER DUKE ENERGY CORPORATION ining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6 SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIAITHK CAL BLOCKS COMMENTS Circumferential Welds B09.021.001 2NC2FW62-19 MCFI-2NC62 NDE-35 PT SS 3.000 Circumferential NC XXS 0.600 Class A Pipe to Valve 2NC32B B09.021.013 2NC2FW62-16 MCFI-2NC62 NDE-35 PT SS 3.000 Circumferential NC 160 0.438 Class A Elbow to Pipe B09.021.014 2NC2FW15-26 MCFI-2NC15 NDE-35 PT SS 2.000 Circumferential NC 160 0.344 Class A Pipe to Reducer B09.021.101 2NV2FW229-2 MCFI-2NV229 NDE-35 PT SS 3.000 Circumferential NV 160 0.438 Class A Stress weld Pipe to Valve 2NV18 B09.021.102 2NV2FW229-4 MCFI-2NV229 NDE-35 PT SS 3.000 Circumferential NV 160 0.438 Class A Stress weld Valve 2NV14 to Pipe Total B09.021 Items:
5 Plan Report Page 30 05/17/2002
EOC 14 CATEGORY B-J, Pressure Retaining Welds In Piping Branch Pipe Connection Welds ITEM NUMBER ID NUMBER SYS ISO/DWG NUN DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6 MBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS Less Than NPS 4 ****
B09.032.050 2NIP102-2 MCFI-2N112 NDE-35 PT SS 2.000 Branch NI 160/6000 0.344 Class A Pipe to WB B09.032.051 2NIP1 19-2 MCFI-2N114 NDE-35 PT SS 2.000 Branch NI 160/6000 0.344 Class A WB to Pipe B09.032.052 2NIP132-2 MCFI-2Nl15 NDE-35 PT SS 2.000 Branch NI 160/6000 0.344 Class A Pipe to WB Total B09.032 Items:
3 Plan Report Page 31 05/17/2002
EOC 14 CATEGORY B-J, Pressure Retaining Welds In Pipingi Socket Welds ITEM NUMBER ID NUMBER SYS ISO/DWG NU DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6 MBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS 809.040.001 2NC2FW15-27 MCFI-2NC15 NDE-35 PT SS 2.000 Socket NC 160 0.344 Class A Stress weld Elbow to Pipe B09.040.002 2NC2FW15-28 MCFI-2NC15 NDE-35 PT SS 2.000 Socket NC 160 0.344 Class A Stress weld Pipe to Elbow B09.040.003 2NC2FW15-29 MCFI-2NC15 NDE-35 PT SS 2.000 Socket NC 160 0.344 Class A Stress weld Elbow to Pipe B09.040.004 2NC2FW15-30 MCFI-2NC15 NDE-35 PT SS 2.000 Socket NC 160 0.344 Class A Stress weld Pipe to Elbow B09.040.005 2NC2FW1 5-31 MCFI-2NC15 NDE-35 PT SS 2.000 Socket NC 160 0.344 Class A Stress weld Valve 2NV222 to Pipe B09.040.007 2NC2FW47-12 MCFI-2NC47 NDE-35 PT SS 2.000 Socket NC 160 0.344 Class A Nozzle to Pipe B09.040.015 2NC2FW79-12 MCFI-2NC79 NDE-35 PT SS 2.000 Socket NC 160 0.344 Class A Stress weld Reducer to Full Coupling B09.040.064 2NI2FW116-8 MCFI-2NI116 NDE-35 PT SS 2.000 Socket NI Class A 160/6000 Elbow to Pipe 0.344 Plan Report Page 32 05/17/2002
EOC 14 CATEGORY B-J, Pressure Retaining Welds In Piping e
Esokt Welds DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS B09.040.115 2NV2FW230-5 MCFI-2NV230 NDE-35 PT SS 2.000 Circumferential NV 160/6000 0.344 Class A Stress weld Pipe to Elbow B09.040.116 2NV2FW230-4 MCFI-2NV230 NDE-35 PT SS 2.000 Socket NV 160/6000 0.344 Class A Stress weld Elbow to Pipe B09.040.117 2NV2FW230-3 MCFI-2NV230 NDE-35 PT SS 2.000 Socket NV 160/6000 0.344 Class A Stress weld Pipe to Elbow B09.040.118 2NV2FW230-2 MCFI-2NV230 NDE-35 PT SS 2.000 Socket NV 160/6000 0.344 Class A Stress weld Elbow to Pipe B09.040.119 2NV2FW230-1 MCFI-2NV230 NDE-35 PT SS 2.000 Socket NV 160 0.344 Class A Stress weld Pipe to Valve 2NV22 Total B09.040 Items:
Total B09 Items:
13 71 Plan Report Page 33 05/17/2002
EOC 14 CATEGORY B-O, Pressure Retaining Welds In Control Rod Housings Reactor Vessel ITEM NUMBER ID NUMBER DUKE ENERGY CRPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 Plan Report Page 34 05/17/2002 Inservice Inspection Plan for Interval 2 Outage 6 SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIAiTHK CAL BLOCKS COMMENTS
B14.010.022 2RPV-CRDM-76 MCM 2201.01-21 NDE-35 PT SS-Inconel 4.000 CRD HOUSING WELD (PERIPHERAL)
NC MCM 2201.01-20 0.642 Class A Total B14.010 Items:
1 Total B14 Items:
1
EOC 14 CATEGORY C-A. Pressure Retaining Welds In Pressure Vessels
- Shell Circumferential Welds ITEM NUMBER ID NUMBER SYS ISO/DWG NUMB DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6 3ERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS C01.010.090 2RCPA-8-1 MCM 1201.04-197 NDE-630 UT SS 6.660 50319 RECIPROCATING CHARGING PUMP Circumferential NV 0.495 ACCUMULATOR Class B FLANGE to FLANGE TO SHELL SHELL Total C01.010 Items
1 Plan Report Page 35 05/17/2002
EOC 14 CATEGORY C-A, Pressure Reta In Pressure Vessels
- Head Circumferential Welds ITEM NUMBER ID NUMBER DUKE ENERGY CORPORATION ining Welds INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6 SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS Plan Report Page 36 05/17/2002 C01.020.074 5141-3-HD1 MCM 1201.06-054 NDE-630 UT SS 10.920 50428 REGENERATIVE HEAT EXCH. NOZZLE BELTTO Circumferential NV MC 2554-1.2 1.075 HEAD (SHELL 3)
Class B NOZZLE BELT to TO BE DONE FROM SHELL SIDE HEAD(SHELL 3)
C01.020.075 5141-3-HD2 MCM 1201.06-054 NDE-630 UT SS 10.920 50428 REGENERATIVE HEAT EXCH. SHELLTO HEAD Circumferential NV MC 2554-1.2 1.075 (SHELL 3)
Class B SHELL to TO BE DONE FROM SHELL SIDE HEAD(SHELL 3)
Total C01.020 Items:
2 I
EOC 14 CATEGORY C-A, Pressure Retaining Welds In Pressure Vessels ubesheet-to-Shell Weld ITEM NUMBER ID NUMBER SYS ISO/DWG DUKE ENERGYOCORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6 NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS Plan Report Page 37 05/17/2002 C01.030.024 5141-3-NB-TS MCM 1201.06-054 NDE-630 UT SS-CS 10.920 50428 REGENERATIVE HEAT EXCH.NOZZLE BELTTO Circumferential NV MC 2554.1-2 1.075 TUBESHEET(SHELL 3)
Class B NOZZLE BELT (SHELL2) to TUBESHEET C01.030.025 5141-3-TS-SH MCM 1201.06-054 NDE-630 UT SS-CS 10.920 50428 REGENERATIVE HEAT EXCH. TUBESHEET TO Circumferential NV MC 2554.1-2 1.075 SHELL(SHELL 3)
Class B TUBESHEET to SHELL Total C01.030 Items:
Total 001 Items:
2 5
EOC 14 CATEGORY C-B, Pressure Retaining Nozzle Welds In Vessels
- Nozzles in Vessels <= 1/2 in. Nominal Thickness ITEM NUMBER ID NUMBER SYS ISO/DWG N1 DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6 NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS Plan Report Page 38 05/17/2002 Nozzle-to-Shell (or Head) Weld C02.011.003 2BCSHX-A-INLET MCM 1201.06-090/1 NDE-35 PT SS 10.000 2B CONTAINMENT SPRAY HEAT EXCH. A INLET Circumferential NS MCM 1201.06-094 0.365 NOZZLE Class B HX(2B) to NOZZLE C02.011.004 2BCSHX-B-OUTLET MCM 1201.06-090/1 NDE-35 PT SS 10.000 2BCONTAINMENT SPRAY HEAT EXCH. B Circumferential NS MCM 1201.06-094 0.365 OUTLET NOZZLE Class B HX(2B) to NOZZLE Total C02.011 Items:
2 Total C02 Items:
2
EOC 14 CATEGORY C-C, Integral Attachments For Vessels, Piping, Pumps, And Valves ITEM NUMBER ID NUMBER SYS ISO/DWC DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6 3NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS Integrally Welded Attachments C03.030.001 2CCPUMP-2A-LEG MCM 1201.05-228 NDE-35 PT SS 0.000 CENTRIFUGAL CHARGING PUMP 2A NV 0.000 (4 SUPPORT LEGS)
Class B Total C03.030 Items:
1 Total C03 Items:
1 Plan Report Page 39 05/17/2002
EOC 14 CATEGORY C-F-l, Pressure Retaining Welds In Austenitic SS or High Alloy Piping
- P!oina Welds >= 3/8 in. Nominal Wall Thickness Wor Piping > NPS 4 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6 PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS Circumferential Weld C05.011.020 2NDP11-2 MCFI-2ND10 NDE-600 UT SS 12.000 50313 Circumferential ND STD 0.375 Class B Elbow to Pipe C05.011.02OA2NDP1O1-2 MCFI-2ND10 NDE-35 PT SS 12.000 Circumferential ND STD 0.375 Class B Elbow to Pipe C05.011.022 2ND2F-199 MCFI-2ND10 NDE-600 UT SS 12.000 50313 Circumferential ND STD 0.375 Class B Pipe to Elbow C05.011.022A 2ND2F-199 MCFI-2ND10 NDE-35 PT SS 12.000 Circumferential ND STD 0.375 Class B Pipe to Elbow C05.011.023 2ND2F-215 MCFI-2ND10 NDE-600 UT SS 12.000 50313 Circumferential ND STD 0.375 Class B Elbow to Pipe C05.011.023A2ND2F-215 MCFI-2ND10 NDE-35 PT SS 12.000 Circumferential ND STD 0.375 Class B Elbow to Pipe C05.011.038 2ND2FW16-13 MCFI-2ND16 NDE-600 UT SS 12.000 50313 Circumferential ND STD 0.375 Class B Elbow to Pipe C05.011.038A 2ND2FW16-13 MCFI-2ND16 NDE-35 PT SS 12.000 Circumferential Class B ND STD Elbow to Pipe 0.375 Plan Report Page 40 05/17/2002
EOC 14 CATEGORY C-F-l. Pressure Retaining Welds In Austenitic SS or High Alloy Piping Wiping Welds >= 3/8 in. Nominal Wall Thickness norPiing >NPS 4 DUKE ENERGYCORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS C05.011.045 2NDP101-1 MCFI-2ND10 NDE-600 UT SS 12.000 Circumferential ND STD 0.375 Class B Pipe to Elbow C05.011.045A 2NDP101-1 MCFI-2ND10 NDE-35 PT SS 12.000 Circumferential ND STD 0.375 Class B Pipe to Elbow C05.011.051 2NDP102-1 MCFI-2ND10 NDE-600 UT SS 12.000 Circumferential ND STD 0.375 Class B Pipe to Elbow C05.011.051A 2NDP1 02-1 MCFI-2ND10 NDE-35 PT SS 12.000 Circumferential ND STD 0.375 Class B Pipe to Elbow C05.011.052 2NDP102-2 MCFI-2ND10 NDE-600 UT SS 12.000 Circumferential ND STD 0.375 Class B Elbow to Pipe C05.011.052A 2NDP1 02-2 MCFI-2ND10 NDE-35 PT SS 12.000 Circumferential ND STD 0.375 Class B Elbow to Pipe C05.011.106 2N12F444 MCFI-2NI14 NDE-600 UT SS 6.000 50211 Circumferential NI 160 0.719 Class B Elbow to Pipe C05.011.106A 2N12F444 MCFI-2N114 NDE-35 PT SS 6.000 Circumferential NI 160 0.719 Class B Elbow to Pipe C05.011.108 2NIP118-1 MCFI-2NI14 NDE-600 UT SS 6.000 50211 Circumferential Class B NI 160 Elbow to Pipe 0.719 Plan Report Page 41 05/17/2002
EOC 14 CATEGORY C-F-i, Pressure Retain In Austenitic SS or High Alloy Pipin
- PiDing Welds >= 3/8 in. Nominal Wall Th norPipin >NPS 4 DUKE ENERGY CORPORATION ing Welds INSERVICE INSPECTION PLAN MANAGEMENT
!9 Inservice Inspection Database Management System hickness McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS C05.011.108A2NIP118-1 MCFI-2NI14 NDE-35 PT SS 6.000 Circumferential NI 160 0.719 Class B Elbow to Pipe C05.011.115 2NIP130-1 MCFI-2NI15 NDE-600 UT SS 6.000 50211 Circumferential NI 160 0.719 Class B Elbow to Pipe C05.011.115A2NIP130-1 MCFI-2N115 NDE-35 PT SS 6.000 Circumferential NI 160 0.719 Class B Elbow to Pipe C05.011.121 2NIP140-1 MCFI-2NI16 NDE-600 UT SS 6.000 50211 Circumferential NI 160 0.719 Class B Elbow to Pipe C05.011.121A 2NIP140-1 MCFI-2NI16 NDE-35 PT SS 6.000 Circumferential NI 160 0.719 Class B Elbow to Pipe C05.011.123 2NIP142-1 MCFI-2NI16 NDE-600 UT SS 6.000 50211 Circumferential NI 160 0.719 Class B Elbow to Pipe C05.011.123A2NIP142-1 MCFI-2NI16 NDE-35 PT SS 6.000 Circumferential NI 160 0.719 Class B Elbow to Pipe C05.011.166 2N12FW28-4 MCFI-2NI28 NDE-600 UT SS 12.000 Circumferential NI 140 1.125 Class B Pipe to Elbow C05,011.166A2NI2FW28-4 MCFI-2NI28 NDE-35 PT SS 12.000 Circumferential Class B NI 140 Pipe to Elbow 1.125 Plan Report Page 42 0511712002
EOC 14 CATEGORY C-F-i, Pressure Retaining Welds In Austenitic SS or High Alloy Piping
- PiipingI Welds >= 3/8 in. Nominal Wall Thickness Efor PilinQ> NPS 4 DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEM ENT Inservice Inspection Database Management System McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS C05.011.167 2N12FW28-7 MCFi-2N128 NDE-600 UT SS 12.000 Circumferential NI 140 1.125 Class B Elbow to Pipe C05.011.167A 2N12FW28-7 MCFI-2N128 NDE-35 PT SS 12.000 Circumferential NI 140 1.125 Class B Elbow to Pipe Total C05.011 Items:
28 Plan Report Page 43 05/17/2002
EOC 14 CATEGORY C-F-l, Pressure Retaining Welds In Austenitic SS or High Alloy Piping WPiping Welds > 115 in. Nom Wall For Piping >=
MNPS 2 And <= NPS 4 ITEM NUMBER ID NUMBER SYS ISO/DWG NU DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6 JMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS Circumferential Weld C05.021.009 2NIP161-2 MCFI-2NI17 NDE-600 UT SS 4.000 50275 Circumferential NI 160 0.531 Class B Elbow to Pipe C05.021.009A 2NIP161-2 MCFI-2N117 NDE-35 PT SS 4.000 Circumferential NI 160 0.531 Class B Elbow to Pipe C05.021.015 2NI2FW78-2 MCFI-2NI78 NDE-600 UT SS 4.000 Circumferential NI 160 0.531 Class B Pipe to Elbow C05.021.015A2N12FW78-2 MCFI-2NI78 NDE-35 PT SS 4.000 Circumferential NI 160 0.531 Class B Pipe to Elbow C05.021.021 2NI2F-56 MCFI-2NI2 NDE-600 UT SS 4.000 50436 Circumferential NI 80 0.337 Class B Tee to Pipe C05.021.021A 2Nl2F-56 MCFI-2N12 NDE-35 PT SS 4.000 Circumferential NI 80 0.337 Class B Tee to Pipe C05.021.054 2NV2FW292-15 MCFI-2NV292 NDE-600 UT SS 3.000 Circumferential NV 160 0.438 Class B Elbow to Pipe C05.021.054A 2NV2FW292-15 MCFI-2NV292 NDE-35 PT SS 3.000 Circumferential Class B NV 160 Elbow to Pipe 0.438 Plan Report Page 44 05/17/2002
EOC 14 CATEGORY C-F-l, Pressure Retaining Welds In Austenitic SS or High Alloy Piping OPloina Welds > 1/5 in. Nom Wall For Piping >=
MNPS 2 And <= NPS 4 DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6 Plan Report Page 45 05/17/2002 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS C05.021.055 2NV2FW292-14 MCFI-2NV292 NDE-600 UT SS 3.000 Circumferential NV 160 0.438 Class B Pipe to Elbow C05.021.055A 2NV2FW292-14 MCFI-2NV292 NDE-35 PT SS 3.000 Circumferential NV 160 0.438 Class B Pipe to Elbow C05.021.067 2NV2FW179-19 MCFI-2NV179 NDE-600 UT SS 3.000 50225 Circumferential NV 160 0.438 Class B Tee to Reducer C05.021.067A 2NV2FW1 79-19 MCFI-2NV179 NDE-35 PT SS 3.000 Circumferential NV 160 0.438 Class B Tee to Reducer C05.021.073 2NV2FW292-1 0 MCFI-2NV292 NDE-600 UT SS 3.000 Circumferential NV 160 0.438 Class B Reducer to Tee C05.021.073A 2NV2FW292-10 MCFI-2NV292 NDE-35 PT SS 3.000 Circumferential NV 160 0.438 Class B Reducer to Tee C05.021.079 2NV2FW53-18 MCFI-2NV53 NDE-600 UT SS 3.000 Circumferential NV 160 0.438 Class B Tee to Pipe C05.021.079A 2NV2FW53-18 MCFI-2NV53 NDE-35 PT SS 3.000 Circumferential NV 160 0.438 Class B Tee to Pipe C05.021.085 2RCPSS-OUT-1 MCFI-2NV32 NDE-600 UT SS 4.000 50438 FOR RECIPROCATING CHARGING PUMP Circumferential Class B Term end NV 40 Nozzle to Flange 0.237 SUCTION STABILIZER DWG. SEE MCM1201.04-0272
EOC 14 CATEGORY C-F-i, Pressure Retaining Welds In Austenitic SS or High Alloy Piping Wiping Welds > 1/5 in. Nom Wall For Piping >=
DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 Plan Report Page 46 mNPS 2 And <= NPS 4 Inservice Inspection Plan for Interval 2 Outage 6 u05 /1712uu ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS C05.021.085A 2RCPSS-OUT-1 MCFI-2NV32 NDE-35 PT SS 4.000 FOR RECIPROCATING CHARGING PUMP Circumferential NV 40 0.237 SUCTION STABILIZER DWG. SEE Class B Term end Nozzle to MCM1201.04-0272 Flange C05.021.091 2NV2FW179-32 MCFI-2NV179 NDE-600 UT SS 4.000 50275 Circumferential NV 160 0.531 Class B Reducer to Elbow C05.021.091A 2NV2FW179-32 MCFI-2NV179 NDE-35 PT SS 4.000 Circumferential NV 160 0.531 Class B Reducer to Elbow C05.021.097 2NV2FW35-14 MCFI-2NV35 NDE-600 UT SS 4.000 50275 Circumferential NV 160 0.531 Class B Tee to Pipe C05.021.097A 2NV2FW35-14 MCFI-2NV35 NDE-35 PT SS 4.000 Circumferential NV 160 0.531 Class B Tee to Pipe C05.021.101 2NV2FW99-23 MCFI-2NV99 NDE-600 UT SS 4.000 50275 Circumferential NV 160 0.531 Class B Pipe to Elbow C05.021.101A2NV2FW99-23 MCFI-2NV99 NDE-35 PT SS 4.000 Circumferential NV 160 0.531 Class B Pipe to Elbow Total C05.021 Items:
24
EOC 14 CATEGORY C-F-l, Pressure Ret In Austenitic SS or High Alloy P Socket Welds ITEM NUMBER ID NUMBER DUKE ENERGY CORPORATION taininc Welds INSERVICE INSPECTION PLAN MANAGEMENT lipinq Inservice Inspection Database Management System McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6 SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIAiTHK CAL BLOCKS COMMENTS C05.030.003 2NI2FW108-10 MCFI-2N1108 NDE-35 PT SS 2.000 Socket NI 160 0.344 Class B Elbow to Reducing Insert C05.030.009 2NI2FW52-10 MCFI-2NI52 NDE-35 PT SS 2.000 Socket NI 160 0.344 Class B Reducing Insert to Elbow C05.030.050 2NV2F-13 MCFI-2NV1 NDE-35 PT SS 2.000 Socket NV 160 0.344 Class B Pipe to Valve 2NV234 C05.030.056 2NV2FW112-8 MCFI-2NV112 NDE-35 PT SS 2.000 Socket NV 160 0.344 Class B Pipe to Elbow C05.030.062 2NV2FW194-16 MCFI-2NV194 NDE-35 PT SS 2.000 Socket NV 160 0.344 Class B Elbow to Pipe C05.030.068 2NV2FW22-1 0 MCFI-2NV22 NDE-35 PT SS 2.000 Socket NV 160 0.344 Class B Tee to Pipe C05.030.074 2NV2FW277-2 MCFI-2NV277 NDE-35 PT SS 2.000 Socket NV 160 0.344 Class B Pipe to Valve 2NV31 C05.030.080 2NV2FW141-14 MCFI-2NV141 NDE-35 PT SS 2.000 Socket NV Class B 40 Elbow to Pipe 0.154 Plan Report Page 47 05/1712002 I
I
EOC 14 CATEGORY C-F-l, Pressure Rel In Austenitic SS or High Alloy P
- ocket Welds ITEM NUMBER ID NUMBER DUKE ENERGY CORPORATION
,taining Welds INSERVICE INSPECTION PLAN MANAGEMENT Niping Inservice Inspection Database Management System McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6 SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS C05.030.086 2NV2FW84-5 MCFI-2NV84 NDE-35 PT SS 2.000 Socket NV 40 0.154 Class B Tee to Reducing Insert Total C05.030 Items:
9 Plan Report Page 48 05/1712002
EOC 14 CATEGORY C-F-l, Pressure Retaining Welds In Austenitic SS or High Alloy Piping ipe Branch Connections of Branch Piping >=
- NPS 2
ITEM NUMBER ID NUMBER SYS ISO/DWG NL DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6 JMBERS PROC INSP REQ MAT/SCH DIA!THK CAL BLOCKS COMMENTS Circumferential Weld C05.041.100 2NV2FW27-30 MCFI-2NV27 NDE-35 PT SS 2.000 Branch NV 40 0.154 Class B Pipe to Half Coupling Total C05.041 Items:
1 Plan Report Page 49 05/17/2002
EOC 14 CATEGORY C-F-2, Pressure Retaining Welds In Carbon Or Low Alloy Steel Piping Wiping Welds >= 318 in. Nominal Wall Thickness nor PipingS> NPS 4 ITEM NUMBER ID NUMBER SYS ISO/DWG NI DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6 UMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS
- Circumferential Weld ****
C05.051.007 2CA2FW52-13 MCFI-2CA52 NDE-600 UT CS 6.000 50331 Circumferential CA 80 0.432 Class B Elbow to Pipe C05.051.007A 2CA2FW52-13 MCFI-2CA52 NDE-25 MT CS 6.000 Circumferential CA 80 0.432 Class B Elbow to Pipe C05.051.009 2CA2FW53-23 MCFI-2CA53 NDE-600 UT CS 6.000 50331 Circumferential CA 80 0.432 Class B Elbow to Elbow C05.051.009A 2CA2FW53-23 MCFI-2CA53 NDE-25 MT CS 6.000 Circumferential CA 80 0.432 Class B Elbow to Elbow C05.051.052 2CF2FW16-4 MCFI-2CF16 NDE-600 UT CS 18.000 50330 Circumferential CF 80 0.938 Class B Valve 2CF30 to Tee C05.051.052A2CF2FW16-4 MCFI-2CF16 NDE-25 MT CS 18.000 Circumferential CF 80 0.938 Class B Valve 2CF30 to Tee C05.051.057 2CF2FW46-10 MCFI-2CF46 NDE-600 UT CS 6.000 50331 Circumferential CF 80 0.432 Class B Elbow to Valve 2CF126B C05.051.057A 2CF2 FW46-1 0 Circumferential Class B MCFI-2CF46 NDE-25 CF MT CS 80 Elbow to Valve 2CF126B Plan Report Page 50 05/17/2002 6.000 0.432
EOC 14 CATEGORY C-F-2, Pressure Retaining Welds In Carbon Or Low Alloy Steel Piping
- PIDing Welds >= 3/8 in. Nominal Wall Thickness nor iping > NPS 4 DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS C05.051.058 2CF2FW46-16 MCFI-2CF46 NDE-600 UT CS 6.000 50331 Circumferential CF 80 0.432 Class B Valve 2CF1 63 to Elbow C05.051.058A 2CF2FW46-16 MCFI-2CF46 NDE-25 MT CS 6.000 Circumferential CF 80 0.432 Class B Valve 2CF163 to Elbow C05.051.064 2CF2FW61-31 MCFI-2CF61 NDE-600 UT CS 16.000 Steam Generator 2A Feedwater Nozzle Transition Circumferential CF MCFD-2591-01.01 80 0.844 Ring to Elbow Class B Elbow to Reference General Requirements Section 8.1.10 S/G-A C05.051.064A 2CF2FW61-31 MCFI-2CF61 NDE-25 MT CS 16.000 Steam Generator 2A Feedwater Nozzle Transition Circumferential CF MCFD-2591 -01.01 80 0.844 Ring to Elbow Class B Elbow to S/G-A C05.051.065 2SGA-W260 MCFI-2CF61 NDE-600 UT CS 16.896 Steam Generator 2A Feedwater Nozzle to Transitio Circumferential Class B Term end C05.051.065A 2SGA-W260 Circumferential Class B Term end CF MCFD-2591-01.01 MCM 2201.01-0207 MCFI-2CF61 CF MCFD-2591-01.01 MCM 2201.01-0207 NDE-25 80 Transition Ring to S/G-A Nozzle MT CS 80 Transition Ring to S/G-A Nozzle 1.300 16.896 1.300 Ring Transition Ring added as a resullt of SGRP
- Reference General Requirements Section 8.1.10 n
Steam Generator 2A Feedwater Nozzle to Transition Ring Transition Ring added as a resullt of SGRP C05.051.205 2SM5C-H MCFI-2SM13 NDE-600 UT CS 10.000 50249 Circumferential SM 1.500 Class B Nozzle Forged nozzle to Transition piece C05.051.205A 2SM5C-H MCFI-2SM13 NDE-25 MT CS 10.000 Circumferential SM 1.500 Class B Nozzle Forged nozzle to Transition piece C05.051.208 2SM5D-E MCFI-2SM9 NDE-600 UT CS 10.000 50249 Circumferential Class B SM 1.500 Nozzle Forged nozzle to Transition piece Plan Report Page 51 05/17/2002
EOC 14 CATEGORY C-F-2, Pressure Re In Carbon Or Low Alloy Steel Pi iping Welds >= 3/8 in. Nominal W, nor NUMinE >
DNIPSB4 ITEM NUMBER ID NUMBER DUKE ENERGY CORPORATION
,taining Welds INSERVICE INSPECTION PLAN MANAGEMENT pinq Inservice Inspection Database Management System all Thickness McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6 SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS C05.051.208A2SM5D-E MCFI-2SM9 NDE-25 MT CS 10.000 Circumferential SM 1.500 Class B Nozzle Forged nozzle to Transition piece C05.051.219 2SM2FW9-9 MCFI-2SM9 NDE-600 UT CS 36.000 50385 Circumferential SM 2.437 Class B Pipe to Valve 2SM1AB C05.051.219A 2SM2FW9-9 MCFI-2SM9 NDE-25 MT CS 36.000 Circumferential SM 2.437 Class B Pipe to Valve 2SM1AB Plan Report Page 52 05/17/2002 Total C05.051 Items:
Total C05 Items:
20 82
EOC 14 CATEGORY C-G, Pressure Retaining Welds In Pumps And Valves Valves ITEM NUMBER ID NUMBER SYS ISO/DWG I DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6 NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS Valve Body Welds C06.020.008A 2SV-13AB-1 MCFI-2SV1 NDE-25 MT CS 6.000 INTAKE TO VALVE BODY WELD SV MCM 1205.09-11/1 0.000 Class B C06.020.008B 2SV-1 3AB-2 MCFI-2SV1 NDE-25 MT CS 6.000 VALVE BODY TO BONNET WELD SV MCM 1205.09-11/1 0.000 Class B Total C06.020 Items:
Total C06 Items:
2 2
Plan Report Page 53 05/17/2002
EOC 14 CATEGORY D-B. Systems In Support Of ECC, CHR, Atmos. Cleanup, And Reactor RHR iegral Attachment ITEM NUMBER ID NUMBER SYS ISO/D\\
DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 Plan Report Page 54 05/17/2002 Inservice Inspection Plan for Interval 2 Outage 6 WG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS Component Supports and Restraints D02.020.042 2MCA-RN-3064 2RN-351 QAL-14 VT-3 NA 0.000 RIGID SUPPORT Rigid Support RN (SHT.20F3) 0.322 PIPE ATT.
Class C Total D02.020 Items:
1
EOC 14 DUKE ENERGY C6RPORATION CATEGORY D-B, Systems In Support Of ECC, INSERVICE INSPECTION PLAN MANAGEMENT CHR, Atmos. Cleanup, And Reactor RHR Inservice Inspection Database Management System eingral Attachment McGuire 2 E
Inservice Inspection Plan for Interval 2 Outage 6 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIAiTHK CAL BLOCKS Plan Report Page 55 05/17/2002 COMMENTS Mechanical and Hydraulic Snubbers D02.030.021 2MCR-KC-4557 2KC-201 QAL-14 VT-3 NA 0.000 MECHANICAL SNUBBER Mech Snubber KC (SHT.1OF5) 0.218 PIPE ATT.
Class C Total D02.030 Items:
1 Total D02 Items:
2
EOC 14 CATEGORY F-A. Supports 1 PipingSupports DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS F01.01 0.008C 2MCR-NC-4225 2NC-21 1 (SHT.1OF1)
QAL-14 VT-3 NA 2.000 Spring Hgr NC 0.000 Class A F01.010.009C 2MCR-NC-4224 2NC-21 1 (SHT.1OFR)
QAL-14 VT-3 NA 2.000 Mech Snubber NC 0.000 Class A F01.010.010C 2MCR-NC-4227 2NC-213(SHT.1OF1)
QAL-14 VT-3 NA 2.000 Mec Snb/Spr Hgr NC 0.000 Class A F01.010.015C 2MCR-NC-4001 2NI-203(SHT.20F2)
QAL-14 VT-3 NA 10.000 Spring Hgr NC 0.000 Class A F01.010.018C 2MCR-NC-4163 2NV-202(SHT.2OF2)
QAL-14 VT-3 NA 1.500 Mech Snubber NC 0.000 Class A F01.010.052C 2MCR-ND-4006 2ND-201(SHT.1OF2)
QAL-14 VT-3 NA 14.000 Mech Snubber ND 0.000 Class A F01.010.082C 2MCR-NI-4617 2NI-201(SHT.2OF2)
QAL-14 VT-3 NA 10.000 Mech Snubber NI 0.000 Class A F01.010.083B 2MCR-NI-4008 2NI-203(SHT.1OF2)
QAL-14 VT-3 NA 6.000 Rigid Support Class A NI 0.000 Plan Report Page 56 05/17/2002
EOC 14 CATEGORY F-A, Supports lass 1 PipgSorts DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS F01.010.084C 2MCR-NI-4580 2NI-203(SHT.1OF2)
QAL-14 VT-3 NA 6.000 Mech Snubber NI 0.000 Class A F01.010.085C 2MCR-NI-4549 2NI-203(SHT.2OF2)
QAL-14 VT-3 NA 10.000 Mech Snubber NI 0.000 Class A F01.010.086B 2MCR-NI-4582 2NI-203(SHT.2OF2)
QAL-14 VT-3 NA 6.000 Rigid Restraint NI 0.000 Class A F01.010.091 C 2MCR-NI-4913 2NI-214(SHT.1 OF1)
QAL-14 VT-3 NA 1.500 Spring Hgr NI 0.000 Class A F01.010.104C 2MCR-NV-4401 2NV-204(SHT.3OF3)
QAL-14 VT-3 NA 3.000 Mech Snubber NV 0.000 Class A F01.010.105B 2MCR-NV-4110 2NV-206(SHT.1OF1)
QAL-14 VT-3 NA 1.500 Rigid Support NV 0.000 Class A F01.010.106A 2MCR-NV-4006 2NV-207(SHT.1OF1)
QAL-14 VT-3 NA 2.000 Rigid Support NV 0.000 Class A F01.010.107B 2MCR-NV-4329 2NV-208(SHT.1OF2)
QAL-14 VT-3 NA 2.000 Rigid Support NV 0.000 Class A F01.010.108B 2MCR-NV-4323 2NV-208(SHT.1OF2)
QAL-14 VT-3 NA 2.000 Rigid Restraint Class A NV 0.000 Plan Report Page 57 05/17/2002
EOC 14 CATEGORY F-A, Supports DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6 SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS BER 7
lass 1 PiinSu orts ITEM NUMBER ID NUME Total F01.010 Items:
1' Plan Report Page 58 05/17/2002
EOC 14 CATEGORY F-A, Supports Class 2 Piinor t s ITEM NUMBER ID NUMBER DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6 SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIAI1HK CAL BLOCKS COMMENTS F01.020.007C 2MCR-CA-H100 2CAO (SHT.1 OF 3)
QAL-14 VT-3 NA 6.000 Spring Hgr CA 0.000 Class B F01.020.053C 2MCR-CF-H403 2CFC(SHT.3OF9)
QAL-14 VT-3 NA 16.000 Hyd Snubber CF 0.000 Class B FO1.020.055C 2MCR-CF-H397 2CFC(SHT.7OF9)
QAL-14 VT-3 NA 18.000 Spring Hgr CF 0.000 Class B F01.020.056A 2MCA-CF-H205 2CFC(SHT.5OF9)
QAL-14 VT-3 NA 18.000 Rigid Support CF 0.000 Class B F01.020.081B 2MCA-FW-5014 2NV-356 SHT.3 QAL-14 VT-3 NA 0.000 Rigid Restraint FW 0.000 Class B F01.020.082B 2MCA-FW-5015 2NV-356 SHT.3 QAL-14 VT-3 NA 0.000 Rigid Restraint FW 0.000 Class B F01.020.083A 2MCA-FW-5016 2NV-356 SHT.3 QAL-1 4 VT-3 NA 0.000 Rigid Support FW 0.000 Class B F01.020.084A 2MCA-FW-5020 2NV-356 SHT.3 QAL-14 VT-3 NA 0.000 Rigid Support FW 0.000 Class B Plan Report Page 59 05/1712002
EOC 14 CATEGORY F-A, Supports lass 2 PipinSuorts DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS F01.020.085B 2MCA-FW-7007 2NV-356 SHT.3 OAL-14 VT-3 NA 0.000 Rigid Restraint FW 0.000 Class B F01.020.086A 2MCA-FW-5012 2FW-350 SHT.1 QAL-14 VT-3 NA 0.000 Rigid Support FW 0.000 Class B F01.020.087A 2MCA-FW-7008 2NV-356 SHT.3 QAL-14 VT-3 NA 0.000 Rigid Support FW 0.000 Class B F01.020.156C 2MCR-NI-4556 2NI-203(SHT.1OF2)
QAL-14 VT-3 NA 6.000 Hyd Snubber NI 0.000 Class B F01.020.157C 2MCR:NI4031 2NI-203(SHT.2OF2)
QAL-14 VT-3 NA 6.000 Mech Snubber NI 0.000 Class B F01.020.270C 2MCR-NV-4198 2NV-224(SHT.1OF1)
QAL-14 VT-3 NA 2.000 Mech Snubber NV 0.000 Class B F01.020.271C 2MCR-NV-4304 2NV-225(SHT.1OF1)
QAL-14 VT-3 NA 2.000 Mech Snubber NV 0.000 Class B F01.020.272B 2MCR-NV-4307 2NV-225(SHT.1OF1)
QAL-14 VT-3 NA 2.000 Rigid Support NV 0.000 Class B F01.020.273C 2MCR-NV-4207 2NV-250(SHT.1OF2)
QAL-14 VT-3 NA 4.000 Mech Snubber Class B NV 0.000 Plan Report Page 60 0511712002
EOC 14 CATEGORY F-A, Supports lass 2 Pipiguorts DUKE ENERGY-CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS F01.020.274B 2MCA-NV-5045 2NV-350(SHT.1OF2)
QAL-14 VT-3 NA 2.000 Rigid Restraint NV 0.000 Class B F01.020.275B 2MCA-NV-5050 2NV-350(SHT.1OF2)
QAL-14 VT-3 NA 2.000 Rigid Restraint NV 0.000 Class B F01.020.276A 2MCA-NV-5053 2NV-350(SHT.1OF2)
QAL-14 VT-3 NA 2.000 Rigid Restraint NV 0.000 Class B F01.020.277B 2MCA-NV-5054 2NV-350(SHT.1OF2)
QAL-14 VT-3 NA 2.000 Rigid Restraint NV 0.000 Class B F01.020.278B 2MCA-NV-5040 2NV-350(SHT.1OF2)
QAL-14 VT-3 NA 3.000 Rigid Restraint NV 0.000 Class B F01.020.279B 2MCA-NV-5044 2NV-350(SHT.1OF2)
QAL-14 VT-3 NA 3.000 Rigid Support NV 0.000 Class B F01.020.280B 2MCA-NV-5017 2NV-350(SHT.2OF2)
QAL-14 VT-3 NA 3.000 Rigid Restraint NV 0.000 Class B F01.020.287A 2MCA-NV-5312 2NV-353(SHT.1OF3)
QAL-14 VT-3 NA 6.000 Rigid Support NV 0.000 Class B F01.020.288B 2MCA-NV-5406 Rigid Restraint Class B 2NV-353(SHT.1OF3)
NV Plan Report Page 61 05/17/2002 QAL-14 VT-3 NA 2.000 0.000
EOC 14 CATEGORY F-A, Supports 2PipingSpports DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIAITHK CAL BLOCKS COMMENTS F01.020.289A 2MCA-NV-5314 2NV-353(SHT.2OF3)
QAL-14 VT-3 NA 4.000 Rigid Restraint NV 0.000 Class B F01.020.290A 2MCA-NV-5305 2NV-353(SHT.2OF3)
QAL-14 VT-3 NA 3.000 Rigid Restraint NV 0.000 Class B FO.020.291 C 2MCA-NV-5316 2NV-353(SHT.3OF3)
QAL-14 VT-3 NA 4.000 Rigid Support NV 0.000 Class B F01.020.292A 2MCA-NV-5601 2NV-356(SHT.1OF4)
QAL-14 VT-3 NA 6.000 Rigid Restraint NV 0.000 Class B F01.020.293B 2MCA-NV-5606 2NV-356(SHT.1OF4)
QAL-14 VT-3 NA 8.000 Rigid Support NV 0.000 Class B F01.020.294A 2MCA-NV-5649 2NV-356(SHT.3OF4)
QAL-14 VT-3 NA 8.000 Rigid Restraint NV 0.000 Class B F01.020.295C 2MCA-NV-5660 2NV-356(SHT.4OF4)
QAL-14 VT-3 NA 4.000 Mech Snubber NV 0.000 Class B F01.020.296A 2MCA-NV-5630 2NV-362(SHT.1OF2)
QAL-14 VT-3 NA 6.000 Rigid Restraint NV 0.000 Class B F01.020.297B 2MCA-NV-5627 Rigid Restraint Class B 2NV-362(SHT.1OF2)
NV Plan Report Page 62 05/17/2002 QAL-14 VT-3 NA 6.000 0.000
EOC 14 CATEGORY F-A, Supports Class 2 PipingqSupports DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIAITHK CAL BLOCKS COMMENTS F01.020.298C 2MCA-NV-6527 2NV-365(SHT.1OF1)
QAL-14 VT-3 NA 3.000 Spring Hgr NV 0.000 Class B F01.020.401 C 2MCA-SA-5163 2SA-350(SHT.2OF2)
QAL-14 VT-3 NA 6.000 Mec Snb/Spr Hgr SA 0.000 Class B F01.020.425B 2MCA-SM-H22 2SMA (SHT.20F5)
QAL-14 VT-3 NA 42.000 Rigid Restraint SM 0.000 Class B F01.020.426A 2MCR-SM-H164 2SMA (SHT.20F5)
QAL-14 VT-3 NA 42.000 Rigid Support SM 0.000 Class B F01.020.429B 2MCR-SM-H165 2SMA (SHT.40F5)
QAL-14 VT-3 NA 42.000 Rigid Restraint SM 0.000 Class B Total F01.020 Items:
40 Plan Report Page 63 05/17/2002
EOC 14 CATEGORY F-A. Supports Class 3 Piping Supports ITEM NUMBER ID NUMBER DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6 SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS F01.030.158A 2MCA-RN-3064 2RN-351 (SHT.20F3)
QAL-14 VT-3 NA 20.000 Rigid Restraint RN 0.000 Class C F01.030.159B 2MCA-RN-3101 2RN-356(SHT.2OF2)
QAL-14 VT-3 NA 18.000 Rigid Restraint RN 0.000 Class C F01.030.160C02MCA-RN-3130 2RN-357(SHT.1OF2)
QAL-14 VT-3 NA 20.000 Mech Snubber RN 0.000 Class C F01.030.161 C 2MCA-RN-3124 2RN-357(SHT.2OF2)
QAL-14 VT-3 NA 18.000 Mec Snb/Spr Hgr RN 0.000 Class C F01.030.162B 2MCA-RN-3141 2RN-358(SHT.1OF2)
QAL-14 VT-3 NA 8.000 Rigid Support RN 0.000 Class C F01.030.163A 2MCA-RN-3144 2RN-358(SHT.1OF2)
QAL-14 VT-3 NA 8.000 Rigid Restraint RN 0.000 Class C FO1.030.164B 2MCA-RN-3158 2RN-358(SHT.1OF2)
QAL-14 VT-3 NA 8.000 Rigid Support RN 0.000 Class C F01.030.165B 2MCA-RN-3382 2RN-358(SHT.2OF2)
QAL-14 VT-3 NA 6.000 Rigid Support Class C RN 0.000 Plan Report Page 64 05/17/2002
EOC 14 CATEGORY F-A, Supports Class 3 iing uorts ITEM NUMBER ID NUMBER DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6 SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIAiTHK CAL BLOCKS COMMENTS F01.030.166B 2MCA-RN-3140 2RN-358(SHT.1OF2)
QAL-14 VT-3 NA 8.000 Rigid Restraint RN 0.000 Class C F01.030.167A 2MCA-RN-3211 2RN-359(SHT.1OF1)
QAL-14 VT-3 NA 8.000 Rigid Restraint RN 0.000 Class C F01.030.168A 2MCA-RN-3205 2RN-359(SHT.1OF1)
QAL-14 VT-3 NA 8.000 Rigid Restraint RN 0.000 Class C F01.030.169A 2MCA-RN-3364 2RN-364(SHT.1OF2)
QAL-14 VT-3 NA 6.000 Rigid Support RN 0.000 Class C Total F01.030 Items:
12 Plan Report Page 65 05/17/2002
EOC 14 CATEGORY F-A. Supports LSurpports other than Piping Supports (Class 1. 2.
M3 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMB DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6 3ERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS F01.040.001 2PZR-SKIRT MC 1070-6 QAL-14 VT-3 NA 0.000 PRESSURIZER SKIRT NC MCM 2201.01-15 0.000 HANGER FUNCTION CATEGORIZATION B Class A MCM 2201.01-16 F01.040.003 2PZR-SUPPORT MC 1070-6 QAL-14 VT-3 NA 0.000 PRESSURIZER UPPER and LOWER SUPPORT NC MC 1070-22 0.000 FRAME Class A HANGER FUNCTION CATEGORIZATION B F01.040.004 2SGA-COLUMN MC 1070-4 QAL-14 VT-3 NA 0.000 2A S/G SUPPORT COLUMNS (4 ASSEMBLIES)
NC MC 1070-17 0.000 HANGER FUNCTION CATEGORIZATION B Class A F01.040.024 2KDHX-SUP-2B QAL-14 VT-3 NA 0.000 2B DIESEL GENERATOR COOLING WATER HX KD MCM1201.06-42 SHT5 0.000 SUPPORT Class C MC 1231-18 HANGER FUNCTION CATEGORIZATION B F01.040.025 2KDC-SUP-2B QAL-14 VT-3 NA 0.000 2B LUBE OIL COOLER SUPPORT KD MCM1301.00-50 0.000 HANGER FUNCTION CATEGORIZATION B Class C MC 1231-19 F01.040.026 2KDP-SUP-2A QAL-14 VT-3 NA 0.000 2A JACKET WATER PUMP SUPPORT KD MCM1301.00-45 0.000 HANGER FUNCTION CATEGORIZATION B Class C F01.040.027 2LDT-SUP-2A QAL-14 VT-3 NA 0.000 2A LUBE OIL FILTER SUPPORT LD MCM1218.04-03 0.000 HANGER FUNCTION CATEGORIZATION B Class C REFERENCE MC-1231-10 (DETAIL Z) AND MC-1231-3 F01.040.032 2RV-SUPPORT-C MCM 1201.01-078 QAL-14 VT-3 NA 0.000 HANGER FUNCTION CATEGORIZATION B NC MCM 1201.01-079 MCM 1117.00-010 Class A 0.000 Plan Report Page 66 05/17/2002 COMMENTS
EOC 14 CATEGORY F-A. Supports DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report L Sumports other than Piping Supports (Class 1, 2, McGuire 2 Page 67 3
Inservice Inspection Plan for Interval 2 Outage 6 05/17/2002 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS F01.040.033 2RV-SUPPORT-D MCM 1201.01-078 QAL-14 VT-3 NA 0.000 HANGER FUNCTION CATEGORIZATION B NC MCM 1201.01-079 0.000 Class A MCM 1117.00-010 F01.040.040 2SGA-LATERALS MC 1070-05.02 QAL-14 VT-3 NA 0.000 2A S/G UPPER AND LOWER LATERAL NC MC 1070-09.02 0.000 SUPPORTS AND SNUBBERS HANGER Class A MC 1070-10.01 FUNCTION CATEGORIZATION C Total F01.040 Items:
10 Total F01 Items:
79
EOC 14 CATEGORY AUG, Augmented Inspections AAugmented Exam, Pipe Rupture Protection ITEM NUMBER ID NUMBER SYS ISOA DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System McGuire 2 Inservice Inspection Plan for Interval 2 Outage 6
/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS Plan Report Page 68 05/17/2002 COMMENTS G03.001.003 2NC2FW22-6 MCFI-2NC22 NDE-600 UT SS 10.000 50209 PIPE RUPTURE PROTECTION Circumferential NC MC 2553-1.0 1.000 TO BE DONE WITH B09.011.012. AUGMENTED Class A Elbow to EXAMINATION Nozzle G03.001.003A2NC2FW22-6 MCFI-2NC22 NDE-35 PT SS 10.000 PIPE RUPTURE PROTECTION Circumferential NC MC 2553-1.0 1.000 TO BE DONE WITH B09.011.012A. AUGMENTED Class A Elbow to EXAMINATION Nozzle G03.001.005 2NC2FW22-10 MCFI-2NC22 NDE-600 UT SS 10.000 50209 PIPE RUPTURE PROTECTION Circumferential NC MC 2553-1.0 1.000 AUGMENTED EXAMINATION Class A Elbow to Pipe G03.001.005A2NC2FW22-10 MCFI-2NC22 NDE-35 PT SS 10.000 PIPE RUPTURE PROTECTION Circumferential NC MC 2553-1.0 1.000 AUGMENTED EXAMINATION Class A Elbow to Pipe Total G03.001 Items:
Total G03 Items:
4 4