ML020990567

From kanterella
Jump to navigation Jump to search
Part 1 of 2, Shearon Harris Nuclear Power Plant, Inservice Inspection Summary Report
ML020990567
Person / Time
Site: Harris Duke Energy icon.png
Issue date: 04/01/2002
From: Field R
Carolina Power & Light Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
HNP-02-051
Download: ML020990567 (173)


Text

SCP&L A Progress Energy Company APR 0 1 200?

SERIAL:

HNP-02-051 10CFR50.55a United States Nuclear Regulatory Commission ATTENTION: Document Control Desk Washington, DC 20555 SHEARON HARRIS NUCLEAR POWER PLANT DOCKET NO. 50-400/LICENSE NO. NPF-63 INSERVICE INSPECTION

SUMMARY

REPORT

Dear Sir or Madam:

In accordance with the reporting requirements of the ASME Boiler and Pressure Vessel Code, 1989 edition,Section XI, Article IWA-6220(c), this letter submits the Inservice Inspection Summary Report for Carolina Power and Light Company's Harris Nuclear Plant (HNP). The enclosed report covers the inspections performed at HNP during Cycle 10 operations, including the Refueling Outage No. 10 in the second 10-year inservice inspection interval.

Questions regarding this matter may be referred to Mr. J. R. Caves at (919) 362-3137.

Sincerely, T A 4J4 Riahard J. Field Manager-Regulatory Affairs Harris Nuclear Plant MSE/mse Enclosure c:

Mr. J. B. Brady, NRC Sr. Resident Inspector Mr. J. M. Givens, Jr. North Carolina Department of Labor Mr. J. M. Goshen, NRC Project Manager Mr. L. A. Reyes, NRC Regional Administrator Harris Nuclear Plant 5413 Shearon Harris Road New Hill, NC 27562 A0 L+7

bc:

Mr. R. H. Bazemore Mr. W. F. Conway Mr. G. W. Davis Mr. R. J. Duncan II Mr. K. N. Harris Ms. L. N. Hartz Mr. C. S. Hinnant Mr. Wayne Gurganis Ms. Terry Hardy Mr. R. D. Martin Mr. J. M. Taylor Mr. John Yadusky Mr. W. G. Wendland Licensing File(s) (2 copies)

Nuclear Records

SERIAL:

HNP-02-051 10CFR50.55a SHEARON HARRIS NUCLEAR POWER PLANT DOCKET NO. 50-400/LICENSE NO. NPF-63 INSERVICE INSPECTION

SUMMARY

REPORT ENCLOSURE

ARTICLE IWA-6000 RECORDS AND REPORTS IWA-6100 SCOPE The requirements for retention of records and re ports (IWA-6300) also apply to those records and re ports of Section III, Divisions 1 and 2 as identified by IWA-6310.

IWA-6200 REQUIREMENTS IWA-6210 OWNER'S RESPONSIBILITY (a) The Owner shall prepare plans and schedules for preservice and inservice examinations and tests to meet the requirements of this Division.

(b) The Owner shall prepare records of the exami nations, tests, replacements, and repairs.

(c) The Owner shall prepare preservice and inservice inspection summary reports for Class I and 2 pressure retaining components and their supports.

IWA-6220 PREPARATION (a) Examination, test, replacement, and repair rec ords shall be prepared in accordance with the require ments of respective Articles of this Division.

(b) A preservice inspection summary report shall be prepared prior to commercial service.

(c) Inservice inspection summary reports shall be prepared at the completion of each inspection con ducted during a refueling outage. Examinations, tests, replacements, and repairs conducted since the preced ing summary report shall be included.

(d) Each summary report required by (b) and (c) above shall contain the following information:

(1) refueling outage number (when applicable);

(2) Owner's Report for Inservice Inspections, Form NIS-1, as shown in Appendix II; and (3) Owner's Report for Repair or Replacements, Form NIS-2, as shown in Appendix II.

(e) Plans, schedules, records, and summary reports shall have a cover sheet providing the following in formation:

(1) date of document completion (2) name and address of Owner (3) name and address of generating plant (4) name or number designation of the unit (5) commercial service date for the unit IWA-6230

SUMMARY

REPORT SUBMITTAL Prior to commercial service, the Owner shall file a preservice inspection summary report, and within 90 days of the completion of the inservice inspection con ducted during each refueling outage, the Owner shall file inservice inspection summary reports with the en forcement and regulatory authorities having jurisdic tion at the plant site.

IWA-6300 RETENTION IWA-6310 MAINTENANCE OF RECORDS The Owner shall retain records and reports identified in IWA-6330 and IWA-6340 as a minimum. The rec ords and reports shall be filed and maintained in a manner which will allow access by the Inspector. The Owner shall provide suitable protection from deteri oration and damage for all records and reports, in accordance with the Owner's Quality Assurance Pro gram, for the service lifetime of the component or system. Storage shall be either at the plant site or at another location that will meet the access and Quality Assurance Program requirements.

IWA-6320 REPRODUCTION AND MICROFILMING Records and reports shall be either the original or a reproduced, legible copy. Radiographs may be micro-45

ATTACHMENT 2 Sheet 1 of 1 Outgoing Regulatory Correspondence Validation Package Cover Sheet

Subject:

+

Agency Due Date:

/-

-0 El Internal El Cornmi-ed Correspondence #: i/P-0 2 -or/

Commitments The following table lists commitments in this correspondence.

Commitment Committed Commitment #

Commitment Date or (Action Request #)

Flagged In Outage Database FSAR Change Determination In accordance with 1 OCFR50.71 (e)(1), this correspondence (check one):

El Requires an FSAR change and (check one):

El RAF #

has been completed, or El Action Request #

has been issued to develop an RAF.

E] Does NOT require an FSAR change El Action Request #

has been issued to determine FSAR impact.

Reviews/Approvals Responsible Individual:

LaA Print Name Responsible Manager:

F&r(c.-k c.

Print Name" Supv.-Lic./Reg. Prog.:

(or designee)

ýA ý - )k t I /k Print Name Signature A--Iv O--,,.

Signature 6 W~ /AAV,

/

Signature

/I /? A7/o1, 1

,Zate I*3/Z8/2.7 Date

/

3

-)I Date AP 611 Rev. 6 Page 13 of 15 4

.4-4

ATTACHMENT 1 Sheet 1 of 1 Outgoing Regulatory Correspondence Review & Approval Cover Sheet

Subject:

, o A

/

_Agency Due Date:

4*t- 0

_z D] Internal 0] Cormmitted Correspondence #:

4,h1-i*/*,ý -eS:E EJ-RC LI INPO/WANO El State of NC

[I Insurance EL Other:

(specify)

Reviewers Each Reviewer by his initials attests that to the best of his knowledge the input provided is accurate and free from Material False Statement.

Reviewers Date Routed Initials/Date Comments

(-/ if yes)

____~j4.-

i-Correspondence to be approved/signed by:

Ihz'c.L--

"V-eiTeX Special Instructions Notary Required:

El Yes

[E'No Special Handling/Overnight Delivery:

EL Yes

[3ao Other:

Return To:

lY*1O&IL-

, \\A

/

xD:S(?

Licensing Lead Extension AP611 Rev. 6 Page 12 of 15 I

I ___

I ___

4-4 4

4-4 4

i 4

4

+

4 4

4-4 4

+

4 4

4 4

4

ACP&L Aherm~

rEmWGWV"er Harris Nuclear Power Plant ISI

SUMMARY

REPORT RFO10 2-2-10

CAROLINA POWER AND LIGHT COMPANY SHEARON HARRIS NUCLEAR POWER PLANT Unit One Inservice Inspection (ISI)

Summary Report For RFO-10 Carolina Power and Light PO Box 1551 Raleigh, NC 27602-1551 Shearon Harris Nuclear Power Plant 5413 Shearon Harris Road New Hill, NC 27562 Date Of Commercial Service May 2, 1987 Document Completion Date March 18, 2002

INDEX SU M M A R Y............................................................................. Section 1 NIS-1 FORM, REPORT OF INSERVICE INSPECTIONS...................... Section 2 WELD EXAMINATION RESULTS................................................ Section 3 ISI Weld Examination Summary Replacement Steam Generator Preservice Exam Summary Preservice NDE Summary of New Piping Components COMPONENT SUPPORTS.......................................................... Section 4 NIS-2 FORMS, REPORT OF REPAIRS AND REPLACEMENTS............ Section 5

SECTION 1

SUMMARY

Summary The Harris Nuclear Power Plant, Unit 1, Ten Year Inservice Inspection Plan was developed to 10CFR50.55 a (g) which implemented, by reference, the ASME Boiler and Pressure Vessel Code,Section XI, 1989 Edition with no Addenda.

The following Summary Report is being submitted pursuant to the reporting requirements of Section XI, Article IWA-6220 (c).

This Summary Report contains the results of the Inservice Inspection (ISI) and Preservice (PSI) examinations performed on selected Class 1 and 2 pressure retaining components and their supports at Harris Nuclear Plant from 5/02/01 to 12/30/01. The RFO-10 examinations were performed during the second period in the second inspection interval.

The typical designation for this duration is 2-2-10, (Second Interval, Second Period, Tenth Refueling Outage). The PSI examinations document the baseline examinations associated with the Steam Generator replacements and Power Uprate modifications.

The components selected for weld examination were from the Second Interval Ten Year Inservice Inspection Plan. The components selected for examination consisted of piping welds, vessel welds, component welds, component supports and integral attachments.

Nondestructive examinations were performed using Magnetic Particle (MT), Liquid Penetrant (PT), Ultrasonic (UT), and Visual (VT) methods. Performance Demonstration Initiative (PDI) ultrasonic techniques were utilized where required. No rejectable indications were noted. Any indications identified during examinations were evaluated and documented as applicable on each weld examination data report. Code Case N-460 was invoked where components achieved greater than 90%, but less than 100% code coverage.

Visual examinations were performed in response to the issues regarding inconel weld cracking identified at V.C. Summer. A bare metal examination was performed on the RPV nozzle to elbow weld on Loops B and C cold legs and on the RPV nozzle to pipe weld on Loop B hot leg. The purpose of the exam was to detect any evidence of cracking or leaking. These particular welds were selected based on the repair history documented during the construction welding process. No evidence of cracking or leaking was observed. The remaining nozzles and surrounding areas were examined with the insulation in place for any signs of leakage. None was detected.

Personnel performing the ISI examinations used CP&L isometrics in conjunction with tagged valves, component supports, points of connection, vessels, wall/floor penetrations, and floor elevations to locate and identify components subject to examination. Permanent component identification reference points were established and marked on the component in accordance with ASME Section XI, Article 111-4000 during PSI. The NDE examination reports, personnel certifications, examination equipment, procedures, calibration standards and the ISI isometrics are listed in the Post Outage Examination Results Report.

The Post Outage Examination Results Report is available upon request.

Due to the replacement of the steam generators, no inservice Eddy Current inspections were performed this outage. Baseline/preservice examinations on the replacement generators were performed prior to RFO-10 in June 2001. All tubes received the required ASME Code examinations. Supplemental examinations were also performed to provide additional information for future examinations. The following describes the examinations performed:

1) 100% of all open tubes with bobbin coil eddy current testing
2) 100% of all open tubes with plus point rotating coil (RC) and pancake coil at the hot leg top-of-tube sheet transitions +/- 2".
3) 100% of all manufacturing dents Ž 2.0 volts with RC probe.
4) 100% of all potential manufacturing lap indications with ultrasonic testing.
5) A sample of benign manufacturing buff marks and other benign indications with RC probe.
6) 100% of the Row 1 U-bend region from the upper hot leg to cold leg support with rotating plus point coil.

Class 1 and 2 Pressure Tests were performed during RFO-10 in accordance with ASME Section XI, IWB-5000 and IWC-5000.

Code Case N-416-1 was invoked to allow use of a System Leakage Test in lieu of a system hydrostatic test for replaced piping components. Code Case N-533 was invoked to allow insulation removal at bolted connections while the system was not at operating pressure. Code Case N-522 was invoked to allow use of Appendix J Testing in lieu of ASME Pressure Tests for selected penetration piping. Code Case N-566, as modified by Relief Request 2RG-009, was invoked to allow evaluation of leakage at bolted connections in lieu of removing one bolt.

All points of leakage were identified and corrective measures were taken to achieve an acceptable condition in each case. The Pressure Test records and supporting documentation are on file at the site and can be made available for review if requested.

No IWE/IWL Inservice Inspections were required this outage. However, a preservice/baseline examination of the Equipment Hatch weld was performed. The results were acceptable.

The repair and replacement summary and the attached ASMIE Section XI, NIS-2 forms detail the component, system, Work Order document, component description and the description of the Work Order activity. Complete repair and replacement documentation for the specific component is maintained on site as a permanent record and is retrievable through the WR (Work Request) [WO (Work Order) document package, which is identified on the NIS-2 form.

SECTION 2 NIS-1 FORM

FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules

1. Owner Carolina Power & Light Company, P.O. Box 1551, Raleigh, N.C. 27602 (Name and Address of Owner)
2. Plant Harris Nuclear Plant, 5413 Shearon Harris Rd.. New Hill, N.C. 27562 (Name and Address of Plant)
3. Plant Unit One (1)
4. Owner Certificate of Authorization (if required) N/A
5. Commercial Service Date 5/2/87
6. National Board Number for Unit 65
7. Systems/Components Inspected (See Systems listed below and Section 3, 4, 5, and 6)

Manufacturer State or Component or Manufacturer or Installer Province National Appurtenance or Installer Serial No.

No.

Board No.

Reactor Vessel Chicago Bridge &

T40 NC212410 4

Auxiliary Feedwater CP&L AF N/A 49 Blowdown CP&L BD N/A 44 Chemical & Volume Control CP&L CS N/A 48 Containment Spray CP&L CT N/A 63 Feedwater CP&L FW N/A 54 Excess Letdown Heat Exchanger Atlas NA NC203942 1999 Main Steam CP&L MS N/A 59 Reactor Coolant CP&L RC N/A 55 Residual Heat Removal CP&L RHR N/A 38 Steam Generator - A Westinghouse 1631 NC203033 Wi 1304 Steam Generator - B Westinghouse 1632 NC203044 Wi 1309 Steam Generator - C Westinghouse 1633 NC203055 Wi 1307 Pressurizer Westinghouse 1641 NC212409 Wi 1306 Safety Injection CP&L SI N/A 46 Service Water CP&L SW N/A 64 RHR Heat Exchanger - 1 A-SA Joseph Oat Corp.

2168-1 B7 NC203028 740 Nitrogen CP&L NI N/A 32 Cont. Spray Pump 1A-SA IRC 107821 N/A 491 Page 1 of 4

FORM NIS-1 (Back)

8. Examination Dates 5/02101 to 12/30/01
9. Inspection Period Identification: Second Inspection Period.
10. Inspection Interval Identification: Second Inspection Interval.
11. Applicable Edition of Section XI:

1989 Edition Addenda: None

12. Date/Revision of Inspection Plan: January 26, 1998/Revision 0.
13. Abstract of Examinations. Include a list of examinations and a statement concerning status of work required for current interval. (See Sections 3 & 4)
14. Abstract of Conditions Noted (See Sections 3 & 4)
15. Abstract of Corrective Measures Recommended and Taken. (See Sections 3 & 4)

We certify that the statements made in this report are correct and the examinations and corrective measures taken conform to the rules of the ASME Code,Section XI.

Certificate of Authorization No. (if applicable)

N/A Expiration Date N/A Date I1t/*1L/O 2002 Signed CP&L By Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB of CT of Hartford, CT.

have inspected the components described in this Owner's Report during the period 5/02/01 to 12/30/01

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property d a loss of any kind arising from or connected with this inspection.

-Commissions NC1444 NIAB Inspector's Signature National Board, State, Province, and Endorsements Date

  • '?

2002 Page 2 of 4

FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules

1. Owner Carolina Power & Light Company, P.O. Box 1551, Raleigh. N.C. 27602 (Name and Address of Owner)
2. Plant Harris Nuclear Plant, 5413 Shearon Harris Rd.. New Hill, N.C. 27562 (Name and Address of Plant)
3. Plant Unit One (1)
4. Owner Certificate of Authorization (if required) N/A
5. Commercial Service Date 5/2187
6. National Board Number for Unit 65
7. Systems/Components Inspected (See Systems listed below and Section 3 & 4)

Manufacturer State or Component or Manufacturer or Installer Province National Appurtenance or Installer Serial No.

No.

Board No.

Steam Generator - A (new)

Westinghouse 12243 NC301552 63 Steam Generator - B (new)

Westinghouse 12244 NC301553 64 Steam Generator - C (new)

Westinghouse 12245 NC301554 65 Reactor Coolant Pump A Westinghouse 1-115E1 11 G01 N/A 16 Reactor Coolant Pump B Westinghouse 2-115E1 11 G01 N/A 17 Reactor Coolant Pump C Westinghouse 3-115E1 11 G01 N/A 18 Page 3 of 4

V-FORM NIS-1 (Back)

8. Examination Dates 5/02/01 to 12/30/01
9. Inspection Period Identification: Second Inspection Period.
10. Inspection Interval Identification: Second Inspection Interval.
11. Applicable Edition of Section XI:

1989 Edition Addenda: None

12. Date/Revision of Inspection Plan: January 26. 1998/Revision 0.
13. Abstract of Examinations. Include a list of examinations and a statement concerning status of work required for current interval. (See Sections 3 & 4)
14. Abstract of Conditions Noted (See Sections 3 & 4)
15. Abstract of Corrective Measures Recommended and Taken. (See Sections 3 & 4)

We certify that the statements made in this report are correct and the examinations and corrective measures taken conform to the rules of the ASME Code,Section XI.

Certificate of Authorization No. (if applicable)

N/A Expiration Date N/A Date --

-Z1.,

2002 Signed CP&L B.

Certificate of Inservice Inspection I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB of CT of Hartford, CT.

have inspected the components described in this Owner's Report during the period 5/02/01 to 12/30/01

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property or a loss of any kind arising from or connected with this inspection.

Commissions NC1444 NIAB Inspector's Signature National Board, State, Province, and Endorsements Date 2002 Page 4 of 4

SECTION 3 WELD EXAMINATION RESULTS ISI Weld Examination Summary Replacement Steam Generator Preservice Exam Summary Preservice NDE Summary of New Piping Components

ISI Weld Examination Summary RFO-1 0 Component ID Exam Requirement Exam Type Exam Date Results iI-AF-005AF-FW-249 B04-02 UT 9/27/01 PASS l1-AF-005AF-FW-250 B04-02 UT 9/27/01 PASS II-AF-005AF-FW-251 B04-02 UT 9/27/01 PASS II-AF-005AF-FW-252 B04-02 UT 9/27/01 PASS II-AF-005AF-SW-A3 B04-02 UT 9/27/01 PASS II-AF-005AF-SW-B3 B04-02 UT 9/27/01 PASS II-AF-005AF-SW-B4 B04-02 UT 9/27/01 PASS II-AF-005AF-SW-B5 B04-02 UT 9/27/01 PASS II-AF-005AF-SW-B6 B04-02 UT 9/27/01 PASS II-AF-005AF-SW-C3 B04-02 UT 9/27/01 PASS II-AF-005AF-SW-C4 B04-02 UT 9/27/01 PASS II-BD-001BD-FW-1 B07-02 MT 10/1/01 PASS II-BD-001BD-FW-2 B07-02 MT 10/1/01 PASS I1-BD-001 BD-SW-A8 B07-02 MT 10/1/01 PASS II-BIT-01 STHW-01 89-02 UT 10/4/01 PASS II-CS-001CS-128-1-SW-2 B03-02 PT 9/20/01 PASS II-CS-001 CS-SW-C8 B03-02 PT 9/20/01 PASS Il-CS-001 CS-SW-G6 B03-02 PT 10/15/01 PASS II-CS-002CS-SW-19 B03-02 PT 9/17/01 PASS I1-CS-021 RH-SW-B7 B03-02 PT 10/15/01 PASS 11-CS-021 RH-SW-B7A B03-02 PT 10/15/01 PASS II-CS-022CS-FW-561 B04-02 UT 10/16/01 PASS II-CS-022CS-FW-562 B04-02 UT 10/16/01 PASS II-CS-089CS-FW-1998 B07-02 PT 10/8/01 PASS Il-CS-089CS-FW-1999 B07-02 PT 10/6/01 PASS II-CS-089CS-SW-B9 B07-02 PT 10/6/01 PASS II-CS-092CS-FW-3028 B04-02 UT 10/12/01 PASS II-CS-092CS-FW-3029 B04-02 UT 10/12/01 PASS II-CS-103CS-496-1-SW-1 B07-02 PT 10/4/01 PASS II-CS-103CS-496-1-SW-2 B07-02 PT 10/4/01 PASS II-CS-103CS-FW-2097 B07-02 PT 10/4/01 PASS Il-CS-103CS-FW-2098 B07-02 PT 10/4/01 PASS I1-CT-007CT-1 1 -FW-33A 89-02 PT 9/24/01 PASS II-CT-007CT-FW-36 89-02 PT 10/3/01 PASS ll-CT-007CT-FW-36 89-02 UT 10/5/01 PASS II-CT-007CT-SW-F3 89-02 PT 10/3/01 PASS I -CT-007CT-SW-F3 89-02 UT 10/3/01 PASS II-CT-007CT-SW-F3A 89-02 PT 10/3/01 PASS II-CT-007CT-SW-F3A 89-02 UT 10/3/01 PASS II-CT-007CT-SW-L3 89-02 PT 10/3/01 PASS II-CT-007CT-SW-L3 89-02 UT 10/3/01 PASS II-CT-007CT-SW-L3A 89-02 PT 10/3/01 PASS II-CT-007CT-SW-L3A 89-02 UT 10/3/01 PASS II-CT-007CT-SW-L3B 89-02 PT 10/3/01 PASS Il-CT-007CT-SW-L3B 89-02 UT 10/3/01 PASS II-CT-007CT-SW-L3C 89-02 PT 10/3/01 PASS II-CT-007CT-SW-L3C 89-02 UT 10/3/01 PASS II-CT-007CT-SW-Q12 89-02 PT 10/3/01 PASS II-CT-007CT-SW-Q12 89-02 UT 10/3/01 PASS II-CT-007CT-SW-Q12A 89-02 PT 10/3/01 PASS II-CT-007CT-SW-Q12A 89-02 UT 10/3/01 PASS

ISI Weld Examination Summary RFO-10 II-CT-007CT-SW-Q12B 89-02 PT 10/3/01 PASS II-CT-007CT-SW-Q12B 89-02 UT 10/3/01 PASS II-CT-008CT-1 2-5-SW-1 89-02 PT 10/4/01 PASS II-CT-008CT-1 2-5-SW-1 89-02 UT 10/4/01 PASS I I-CT-008CT-12-FW-48A 89-02 PT 9/25/01 PASS II-CT-008CT-SW-E8 89-02 PT 10/4/01 PASS II-CT-008CT-SW-E8 89-02 UT 10/4/01 PASS II-CT-008CT-SW-E8A 89-02 PT 10/4/01 PASS II-CT-008CT-SW-E8A 89-02 UT 10/4/01 PASS II-CT-014CT-FW-175 B03-02 UT 10/4/01 PASS II-CT-014CT-FW-175 B03-02 PT 10/4/01 PASS Il-CT-014CT-SW-B3 B03-02 UT 10/4/01 PASS II-CT-014CT-SW-B3 B03-02 PT 10/4/01 PASS II-CT-014CT-SW-B4 B03-02 UT 10/4/01 PASS Il-CT-014CT-SW-B4 B03-02 PT 10/4/01 PASS II-CT-016CT-FW-145 B03-02 PT 9/26/01 PASS Il-CT-016CT-FW-145 B03-02 UT 9/26/01 PASS I I-CT-016CT-H-00951(8) 89-02 PT 9/26/01 PASS II-EL-001 STHW-01 89-02 UT 10/6/01 PASS II-EL-001 STHW-03 89-02 UT 10/6/01 PASS II-FMR-02MS-H-00181(8) 89-02 MT 10/2/01 PASS Il-FMR-02MS-H-00201(5) 89-02 MT 10/2/01 PASS II-FMR-02RC-10-18-FW-1 NA VISUAL 9/24/01 PASS 1I-FMR-02RC-10-18-FW-4 NA VISUAL 9/24/01 PASS II-FMR-03FW-SW-G2 89-02 MT 10/27/01 PASS II-FMR-03FW-SW-G2 89-02 UT 10/27/01 PASS II-FMR-03RC-10-19-FW-4 NA VISUAL 9/24/01 PASS I1-FW-001 FW-36-2-SW-6 B05-02 UT 10/10/01 PASS II-FW-001 FW-FW-469 B05-02 UT 10/9/01 PASS II-FW-001 FW-FW-473 B05-02 UT 10/9/01 PASS II-FW-001 FW-FW-476 B05-02 UT 10/9/01 PASS 1I-FW-001 FW-FW-499 B05-02 UT 10/9/01 PASS Il-FW-001 FW-FW-499 89-02 UT 10/9/01 PASS TI-FW-001 FW-FW-499 89-02 MT 10/6/01 PASS II-FW-001 FW-FW-501 89-02 UT 10/9/01 PASS II-FW-001 FW-FW-501 B05-02 UT 10/9/01 PASS II-FW-001 FW-FW-501 89-02 MT 10/6/01 PASS 11-FW-001 FW-FW-502 B05-02 UT 10/9/01 PASS II-FW-001 FW-FW-502 89-02 MT 10/6/01 PASS I I-FW-001 FW-FW-502 89-02 UT 10/9/01 PASS II-FW-001 FW-FW-503 B05-02 UT 10/9/01 PASS II-FW-001 FW-FW-503 89-02 UT 10/9/01 PASS II-FW-001 FW-FW-503 89-02 MT 10/6/01 PASS I I-FW-001 FW-FW-504 B05-02 UT 10/10/01 PASS I I-FW-001 FW-FW-505 89-02 MT 10/10/01 PASS I I-FW-001 FW-FW-505 B05-02 UT 10/10/01 PASS II-FW-001 FW-FW-505 89-02 UT 10/10/01 PASS II-FW-001 FW-FW-506 89-02 UT 10/10/01 PASS II-FW-001 FW-FW-506 89-02 MT 10/10/01 PASS II-FW-001 FW-FW-506 B05-02 UT 10/10/01 PASS I I-FW-001 FW-FW-507 B05-02 UT 10/9/01 PASS I I-FW-001 FW-FW-507 89-02 MT 10/6/01 PASS

ISI Weld Examination Summary RFO-10 Il-FW-001 FW-FW-507 89-02 UT 10/9/01 PASS II-FW-0O0 FW-FW-508 B05-02 UT 10/10/01 PASS II-FW-001 FW-FW-509 89-02 UT 10/9/01 PASS II-FW-001 FW-FW-509 89-02 MT 10/6/01 PASS II-FW-001 FW-FW-509 B05-02 UT 10/9/01 PASS II-FW-001 FW-FW-510 89-02 UT 10/6/01 PASS II-FW-OO1FW-FW-510 89-02 MT 10/6/01 PASS Il-FW-001 FW-FW-510 B05-02 UT 10/9/01 PASS Il-FW-0O0 FW-SW-A3 B06-02 MT 10/6/01 PASS Il-FW-001 FW-SW-A4 89-02 MT 10/6/01 PASS II-FW-001 FW-SW-A4 B05-02 UT 10/9/01 PASS I 1-FW-O00 FW-SW-A4 89-02 UT 10/9/01 PASS 11-FW-001 FW-SW-B3 B06-02 MT 10/6/01 PASS 11-FW-001 FW-SW-B4 89-02 MT 10/6/01 PASS II-FW-001 FW-SW-B4 B05-02 UT 10/9/01 PASS 11-FW-001 FW-SW-B4 89-02 UT 10/9/01 PASS I1-FW-001 FW-SW-C3 B06-02 MT 10/10/01 PASS 11-FW-001 FW-SW-C4 89-02 UT 10/10/01 PASS 1I-FW-001 FW-SW-C4 B05-02 UT 10/10/01 PASS 1I-FW-001 FW-SW-C4 89-02 MT 10/10/01 PASS II-FW-001 FW-SW-D3 B05-02 UT 10/10/01 PASS I1-FW-001 FW-SW-E3 B05-02 UT 10/10/01 PASS II-FW-001 FW-SW-E4 B05-02 UT 10/10/01 PASS II-FW-001 FW-SW-F3 B05-02 UT 10/10/01 PASS II-FW-0O0 FW-SW-K8 B05-02 UT 10/10/01 PASS II-FW-003AF-FW-267 89-02 MT 10/10/01 PASS II-FW-003AF-FW-267 B04-02 UT 10/15/01 PASS II-FW-003AF-FW-267 89-02 UT 10/15/01 PASS ll-FW-003FW-36-3-SW-1 0 B05-02 UT 9/29/01 PASS lI-FW-003FW-36-3-SW-1 1 B05-02 UT 9/29/01 PASS ll-FW-003FW-36-3-SW-1 2 B05-02 UT 9/29/01 PASS II-FW-003FW-36-3-SW-1 3 B05-02 UT 9/29/01 PASS II-FW-003FW-36-3-SW-2 B05-02 UT 9/29/01 PASS Il-FW-003FW-36-3-SW-3 B05-02 UT 9/29/01 PASS II-FW-003FW-36-3-SW-4 B05-02 UT 9/29/01 PASS II-FW-003FW-36-3-SW-5 B05-02 UT 9/29/01 PASS II-FW-003FW-36-3-SW-6 B05-02 UT 9/29/01 PASS ll-FW-003FW-36-3-SW-7 B05-02 UT 9/29/01 PASS Il-FW-003FW-36-3-SW-8 B05-02 UT 9/29/01 PASS Il-FW-003FW-36-3-SW-9 B05-02 UT 9/29/01 PASS Il-MS-001 MS-FW-286 B05-02 UT 10/15/01 PASS II-MS-0ol MS-FW-286 89-02 UT 10/15/01 PASS Il-MS-OO1MS-FW-286 89-02 MT 10/13/01 PASS I I-MS-001 MS-FW-286A 89-02 UT 10/15/01 PASS I I-MS-001 MS-FW-286A 89-02 MT 10/13/01 PASS II-MS-0Ol MS-FW-286A B05-02 UT 10/15/01 PASS II-MS-OO1MS-SW-B11 B05-02 UT 10/15/01 PASS II-MS-OO1MS-SW-B11 89-02 UT 10/15/01 PASS II-MS-0Ol MS-SW-B11 89-02 MT 10/11/01 PASS II-MS-OO1MS-SW-B12 89-02 UT 10/15/01 PASS Il-MS-0Ol MS-SW-B12 B05-02 UT 10/15/01 PASS I I-MS-OO1MS-SW-B12 89-02 MT 10/11/01 PASS

ISI Weld Examination Summary RFO-10 II-MS-001MS-SW-B13 89-02 UT 10/15/01 PASS II-MS-OO1MS-SW-B13 89-02 MT 10/11/01 PASS II-MS-001MS-SW-B13 B05-02 UT 10/15/01 PASS II-MS-001MS-SW-B14 89-02 MT 10/11/01 PASS II-MS-001MS-SW-B14 B05-02 UT 10/15/01 PASS II-MS-001MS-SW-B14 89-02 UT 10/15/01 PASS II-MS-001MS-SW-B15 89-02 UT 10/15/01 PASS II-MS-OO1MS-SW-B15 89-02 MT 10/11/01 PASS II-MS-001 MS-SW-B15 B05-02 UT 10/15/01 PASS II-MS-OO1MS-SW-B20 B06-02 MT 10/11/01 PASS II-MS-OO1MS-SW-B3 89-02 UT 10/15/01 PASS II-MS-OO1MS-SW-B3 89-02 MT 10/13/01 PASS II-MS-OO1MS-SW-B3 B05-02 UT 10/15/01 PASS II-MS-OO1MS-SW-B30 89-02 MT 10/11/01 PASS I I-MS-001 MS-SW-B30 B05-02 UT 10/15/01 PASS II-MS-001 MS-SW-B30 89-02 UT 10/15/01 PASS Il-MS-0O0 MS-SW-B34 B05-02 UT 10/15/01 PASS II-MS-OO1MS-SW-B34 89-02 UT 10/15/01 PASS lI-MS-OO1MS-SW-B34 89-02 MT 10/11/01 PASS II-MS-001 MS-SW-B35 89-02 MT 10/13/01 PASS II-MS-OO1MS-SW-B35 89-02 UT 10/15/01 PASS I I-MS-O01 MS-SW-B35 B05-02 UT 10/15/01 PASS II-MS-001 MS-SW-B3A 89-02 UT 10/15/01 PASS Il-MS-0O0 MS-SW-B3A 89-02 MT 10/13/01 PASS I I-MS-001 MS-SW-B3A B05-02 UT 10/15/01 PASS II-MS-OO1MS-SW-B4 B05-02 UT 10/15/01 PASS II-MS-OO1MS-SW-B4 89-02 UT 10/15/01 PASS II-MS-OO1MS-SW-B4 89-02 MT 10/13/01 PASS Il-MS-0O0 MS-SW-B5 B05-02 UT 10/15/01 PASS II-MS-OO1MS-SW-B5 89-02 MT 10/13/01 PASS II-MS-OO1MS-SW-B5 89-02 UT 10/15/01 PASS II-MS-001MS-S W-B6 B06-02 MT 10/11/01 PASS II-MS-002MS-FW-565 B05-02 UT 10/9/01 PASS II-MS-002MS-FW-565 89-02 MT 10/8/01 PASS IfI-MS-002MS-FW-565 89-02 UT 10/9/01 PASS II-MS-002MS-FW-566 B05-02 UT 10/9/01 PASS II-MS-002MS-FW-566 89-02 MT 10/8/01 PASS II-MS-002MS-FW-566 89-02 UT 10/9/01 PASS II-MS-002MS-FW-567 B05-02 UT 10/9/01 PASS II-MS-002MS-FW-567 89-02 MT 10/8/01 PASS II-MS-002MS-FW-567 89-02 UT 10/9/01 PASS II-MS-002MS-FW-568 B05-02 UT 10/9/01 PASS II-MS-002MS-FW-568 89-02 MT 10/8/01 PASS II-MS-002MS-FW-568 89-02 UT 10/9/01 PASS II-MS-002MS-FW-691 89-02 MT 10/8/01 PASS II-MS-002MS-FW-691 89-02 UT 10/8/01 PASS II-MS-002MS-FW-692 89-02 MT 10/8/01 PASS II-MS-002MS-FW-692 89-02 UT 10/8/01 PASS I I-MS-002MS-SW-C3 B05-02 UT 10/9/01 PASS II-MS-002MS-SW-C3 89-02 MT 10/8/01 PASS II-MS-002MS-SW-C3 89-02 UT 10/9/01 PASS lII-MS-009MS-44-2-SW-1 B06-02 MT 10/9/01 PASS

ISI Weld Examination Summary RFO-10 II-MS-009MS-44-2-SW-2 B06-02 MT 10/9/01 PASS II-MS-009MS-44-2-SW-3 B06-02 MT 10/9/01 PASS II-MS-009MS-FW-585 B06-02 MT 10/8/01 PASS II-MS-009MS-FW-586 B06-02 MT 10/13/01 PASS II-RC-027RC-1 14-F-01 (1-12) 89-02 VT-1 10/2/01 PASS II-RCP-01 RCPB-SBOLT(1-12) 89-02 VT-1 9/27/01 PASS Il-RCP-01 RCPC-CSBOLT(1-8) 89-02 VT-1 9/26/01 PASS I-RCP-01 RCPC-SBOLT(1 -12) 89-02 VT-1 9/26/01 PASS II-RH-001SI-1-FW-4A 89-02 PT 10/2/01 PASS II-RH-001SI-FW-12 89-02 PT 9/18/01 PASS II-RH-001SI-FW-12 89-02 UT 9/19/01 PASS II-RH-001SI-FW-12A 89-02 PT 9/18/01 PASS II-RH-001SI-FW-12A 89-02 UT 9/19/01 PASS II-RH-001SI-SW-F4 89-02 PT 9/18/01 PASS II-RH-001SI-SW-F4 89-02 UT 9/19/01 PASS II-RH-001SI-SW-F4A 89-02 PT 9/18/01 PASS ll-RH-001SI-SW-F4A 89-02 UT 9/19/01 PASS I1-RH-001SI-SW-F4B 89-02 PT 9/18/01 PASS Il-RH-001 SI-SW-F4B 89-02 UT 9/19/01 PASS II-RH-001 SI-SW-F4C 89-02 PT 9/18/01 PASS ll-RH-001SI-SW-F4C 89-02 UT 9/19/01 PASS II-RH-002RH-SW-E3 89-02 UT 9/19/01 PASS II-RH-002RH-SW-E3 89-02 PT 9/18/01 PASS II-RH-002RH-SW-E3A 89-02 UT 9/19/01 PASS Il-RH-002RH-SW-E3A 89-02 PT 9/18/01 PASS ll-RH-002RH-SW-E3B 89-02 UT 9/19/01 PASS Il-RH-002RH-SW-E3B 89-02 PT 9/18/01 PASS II-RH-002RH-SW-E3C 89-02 UT 9/18/01 PASS Il-RH-002RH-SW-E3C 89-02 PT 9/18/01 PASS Il-RH-002SI-2-FW-16A 89-02 PT 10/3/01 PASS lI-RH-002SI-FW-14 89-02 PT 10/3/01 PASS II-RH-002SI-FW-14 89-02 UT 10/3/01 PASS II-RH-002SI-FW-14A 89-02 PT 10/3/01 PASS II-RH-002SI-FW-14A 89-02 UT 10/3/01 PASS II-RH-002SI-FW-21 89-02 UT 9/19/01 PASS II-RH-002SI-FW-21 89-02 PT 9/18/01 PASS II-RH-002SI-FW-21A 89-02 PT 9/18/01 PASS II-RH-002SI-FW-21A 89-02 UT 9/19/01 PASS II-RH-002SI-FW-23 89-02 PT 10/12/01 PASS II-RH-002SI-FW-23 89-02 UT 10/12/01 PASS II-RH-002SI-FW-23A 89-02 PT 10/12/01 PASS II-RH-002SI-FW-23A 89-02 UT 10/12/01 PASS I I-RH-004RH-1 2-1 -SW-1 B03-02 PT 9/20/01 PASS II-RH-004RH-FW-75 B03-02 PT 9/20/01 PASS 11-RH-004RH-FW-77 B03-02 PT 9/20/01 PASS II-RH-009RH-FW-14 B03-02 UT 10/6/01 PASS ll-RH-009RH-FW-14 B03-02 PT 10/6/01 PASS II-RH-009RH-FW-15 B03-02 PT 10/6/01 PASS II-RH-009RH-FW-15 B03-02 UT 10/6/01 PASS II-RH-009RH-FW-15A B03-02 PT 10/6/01 PASS

  • I-RH-009RH-FW-15A B03-02 UT 10/6/01 PASS Il-RH-009RH-SW-F3 B03-02 PT 10/6/01 PASS

ISI Weld Examination Summary RFO-10 II-RH-009RH-SW-F3 B03-02 UT 10/6/01 PASS I I-RH-009RH-SW-F3A B03-02 PT 10/6/01 PASS II-RH-009RH-SW-F3A B03-02 UT 10/6/01 PASS II-RH-010RH-FW-193 B03-02 PT 10/6/01 PASS II-RH-010RH-FW-193 B03-02 UT 10/6/01 PASS II-RH-010RH-FW-2 B03-02 PT 10/8/01 PASS II-RH-010RH-FW-2 B03-02 UT 10/8/01 PASS II-RH-010RH-FW-2A B03-02 PT 10/8/01 PASS

!I-RH-010RH-FW-2A B03-02 UT 10/8/01 PASS 1I-RHR-01 RHRA-STHW-01A,B,C 89-02 UT 9/17/01 PASS I1-RHR-01 RHRA-STVW-06A,B,C 89-02 PT 9/17/01 PASS II-RHRP-1 RHRP-A-WA1 89-02 PT 9/20/01 PASS II-RHRP-1 RHRP-A-WA2 89-02 PT 9/20/01 PASS II-RHRP-1 RHRP-A-WA3 89-02 PT 9/20/01 PASS II-RV-001 BCONO-B(1-3) 89-02 VT-1 10/12/01 PASS II-RV-001 RVNUT(20-38) 89-02 MT 11/7/01 PASS II-RV-001 RVSTUD(20-38) 89-02 UT 11/7/01 PASS 11-RV-001 RVSTUD(20-38) 89-02 MT 11/7/01 PASS II-RV-001 RVWSH(20-38) 89-02 VT-1 11/6/01 PASS II-SI-004SI-FW-27 89-02 UT 10/3/01 PASS II-SI-004SI-FW-27 89-02 PT 10/3/01 PASS II-SI-004SI-FW-28 89-02 UT 10/3/01 PASS II-SI-004SI-FW-28 89-02 PT 10/3/01 PASS II-SI-004SI-FW-29 89-02 PT 10/2/01 PASS II-SI-004SI-FW-29 89-02 UT 10/3/01 PASS II-SI-004SI-FW-34 89-02 UT 10/3/01 PASS II-SI-004SI-FW-34 89-02 PT 10/2/01 PASS II-SI-004SI-SW-D3 89-02 UT 10/3/01 PASS II-SI-004SI-SW-D3 89-02 PT 10/2/01 PASS II-SI-004SI-SW-E4 89-02 UT 10/3/01 PASS II-SI-004SI-SW-E4 89-02 PT 10/3/01 PASS II-SI-009SI-FW-280 89-02 PT 10/8/01 PASS II-SI-009SI-FW-280 89-02 UT 10/8/01 PASS II-SI-01OSI-99-FW-272 89-02 UT 10/3/01 PASS II-SI-01O0SI-99-FW-272 89-02 PT 10/2/01 PASS II-SI-010SI-SW-B6 89-02 UT 10/3/01 PASS II-SI-010SI-SW-B6 89-02 PT 10/2/01 PASS II-SI-011 SI-FW-474 89-02 UT 10/3/01 PASS II-SI-011SI-FW-474 89-02 PT 10/2/01 PASS II-SI-011SI-FW-477 89-02 UT 10/3/01 PASS II-SI-011SI-FW-477 89-02 PT 10/2/01 PASS II-SI-011SI-SW-F3 89-02 UT 10/3/01 PASS II-SI-011SI-SW-F3 89-02 PT 10/2/01 PASS II-SI-016SI-FW-36 89-02 UT 10/12/01 PASS II-SI-016SI-FW-36 89-02 PT 10/1/01 PASS II-SI-016SI-FW-395 89-02 PT 10/1/01 PASS II-SI-016SI-FW-396 89-02 PT 10/9/01 PASS II-SI-016SI-SW-D9 89-02 PT 10/1/01 PASS II-SI-016SI-SW-E3 89-02 PT 10/1/01 PASS II-SI-017S I-140-3-SW-1 89-02 PT 10/1/01 PASS II-SI-017SI-FW-405 89-02 PT 10/1/01 PASS II-SI-018SI-FW-383 89-02 PT 10/1/01 PASS

ISI Weld Examination Summary RFO-10 II-SI-019SI-FW-277 89-02 UT 10/12/01 PASS II-SI-019SI-FW-277 89-02 PT 10/1/01 PASS II-SI-019SI-FW-351 89-02 PT 10/9/01 PASS II-SI-019SI-FW-352 89-02 PT 10/1/01 PASS II-SI-019SI-SW-N3 89-02 PT 10/1/01 PASS II-SI-022SI-FW-566 89-02 PT 10/9/01 PASS II-SI-022SI-FW-566 89-02 UT 10/10/01 PASS II-SI-022SI-FW-566A 89-02 PT 10/9/01 PASS II-SI-022SI-FW-566A 89-02 UT 10/10/01 PASS II-SI-022SI-SW-A6 89-02 PT 10/9/01 PASS 11-SI-022SI-SW-A6 89-02 UT 10/10/01 PASS II-SI-022SI-SW-B3 89-02 PT 10/9/01 PASS Il-SI-022SI-SW-B3 89-02 UT 10/10/01 PASS II-SI-023S1-1 70-1 -SW-1 89-02 PT 10/2/01 PASS 11-SI-023S1-170-1 -SW-1 89-02 UT 10/2/01 PASS II-SI-023SI-FW-561 89-02 PT 10/2/01 PASS II-SI-023SI-FW-561 89-02 UT 10/11/01 PASS II-SI-023SI-SW-A4 89-02 PT 10/2/01 PASS II-SI-023SI-SW-A4 89-02 UT 10/2/01 PASS 11-SI-0241 SI-356 INT 89-02 VT-3 10/9/01 PASS II-SI-024SI-356 VBB(1 -16) 89-02 VT-1 10/9/01 PASS II-SI-024SI-FW-572 89-02 PT 10/15/01 PASS II-SI-024SI-FW-572 89-02 UT 10/15/01 PASS II-SI-025SI-H-02541(8) 89-02 PT 10/5/01 PASS II-SI-025SI-SW-F5 89-02 UT 10/5/01 PASS lI-SI-025SI-SW-F5 89-02 PT 10/5/01 PASS lI-SI-026SI-FW-592 89-02 UT 10/15/01 PASS II-S I-026SI-FW-592 89-02 PT 10/15/01 PASS II-SI-026SI-SW-F3 89-02 PT 10/5/01 PASS II-S1-026SI-SW-F3 89-02 UT 10/5/01 PASS II-Sl-026SI-SW-H8 89-02 PT 10/5/01 PASS II-SI-026SI-SW-H8 89-02 UT 10/5/01 PASS II-SI-028SI-FW-610 89-02 PT 10/11/01 PASS II-S1-028SI-FW-610 89-02 UT 10/11/01 PASS II-SI-028SI-SW-B3 89-02 UT 10/11/01 PASS 11-SI-028SI-SW-B3 89-02 PT 10/11/01 PASS

Replacement Steam Generator Preservice Exam Summary Component ID Exam Requirement Exam Type Exam Dates Results A Generator (SN 12243) 6/11-23/98 Channel Head to Tubesheet Girth Weld 89-02 UT Pass Primary Nozzle Inside Radius (Cold Leg) 89-02 UT Pass Primary Nozzle Inside Radius (Hot Leg) 89-02 UT Pass Primary Nozzle to Safe End (Cold Leg) 89-02 PT/UT Pass Primary Nozzle to Safe End (Hot Leg) 89-02 PT/UT Pass Tube Sheet to Stub Barrel Weld 89-02 UT Pass Upper Barrel to Eliptical Head Weld 89-02 UT Pass Feedwater Nozzle to Shell Weld 89-02 UT Pass Auxiliary Feedwater Nozzle to Shell Weld 89-02 UT Pass Feedwater Nozzle Inner Radius 89-02 UT Pass B Generator (SN 12244) 7/15-20/98 Channel Head to Tubesheet Girth Weld 89-02 UT Pass Primary Nozzle Inside Radius (Cold Leg) 89-02 UT Pass Primary Nozzle Inside Radius (Hot Leg) 89-02 UT Pass Primary Nozzle to Safe End (Cold Leg) 89-02 PT/UT Pass Primary Nozzle to Safe End (Hot Leg) 89-02 PT/UT Pass Tube Sheet to Stub Barrel Weld 89-02 UT Pass Upper Barrel to Eliptical Head Weld 89-02 UT Pass Feedwater Nozzle to Shell Weld 89-02 UT Pass Auxiliary Feedwater Nozzle to Shell Weld 89-02 UT Pass Feedwater Nozzle Inner Radius 89-02 UT Pass C Generator (SN 12245) 6/9-23/98 Channel Head to Tubesheet Girth Weld 89-02 UT Pass Primary Nozzle Inside Radius (Cold Leg) 89-02 UT Pass Primary Nozzle Inside Radius (Hot Leg) 89-02 UT Pass Primary Nozzle to Safe End (Cold Leg) 89-02 PT/UT Pass Primary Nozzle to Safe End (Hot Leg) 89-02 PT/UT Pass Tube Sheet to Stub Barrel Weld 89-02 UT Pass Upper Barrel to Eliptical Head Weld 89-02 UT Pass Feedwater Nozzle to Shell Weld 89-02 UT Pass Auxiliary Feedwater Nozzle to Shell Weld 89-02 UT Pass Feedwater Nozzle Inner Radius 89-02 UT Pass

Preservice NDE Summary of Piping Components Preservice Examination Summary of Piping Components WP&IR # P-MSA-0001 MAINSTEAM "A" ASME III NC (CLASS 2)

Pipe RT Final FSK# 9700807 Weld #

Size Wall Thick.

Date UT & MT - XI RT-418 Final "A" MS M-2041 1 -MS-77-FW-293 32" Min. 1.051 11/27/01 UT & MT Accept RT-375 Final "A" MS M-2041 1-MS-77-FW-310 32" Min. 1.051 11/24/01 UT & MT Accept WP&IR # P-MSB-0001 MAINSTEAM "B" ASME III NC (CLASS 2 Pipe RT Final FSK# 9700807 Weld #

Size Wall Thick.

Date UT & MT - XI RT-428 Final "B" MS M-2040 1-MS-72-FW-294 32" Min. 1.051 11/28/01 UT & MT Accept RT-405 "B" MS M-2040 1 -MS-72-FW-330 32" Min. 1.051 11/25/01 UT & MT Accept WP&IR # P-MSC-0001 MAINSTEAM "C" ASME III NC (CLASS 2)

Pipe RT Final FSK# 9700807 Weld #

Size Wall Thick.

Date UT & MT - XI RT-421 Final "C" MS M-2042 1 -MS-80-288 32" Min. 1.051 11/28/01 UT & MT Accept RT-378 Final "C" MS M-2042 1-MS-80-310 32" Min. 1.051 11/25/01 UT & MT Accept

~~~~ ~ ~~I_

_I_

I__ I__

_I

Preservice NDE Summary of New Piping Components Preservice Examination Summary of Piping Components WP&IR # P-MSA-0001 MAINSTEAM "A" ASME III NC (CLASS 2)

Pipe RT Final FSK# 9700807 Weld #

Size Wall Thick.

Date UT & MT - XI RT-418 Final "A" MS M-2041 1 -MS-77-FW-293 32" Min. 1.051 11/27/01 UT & MT Accept RT-375 Final "A" MS M-2041 1-MS-77-FW-310 32' Min. 1.051 11/24/01 UT & MT Accept WP&IR # P-MSB-0001 MAINSTEAM "B" ASME IlI NC (CLASS 2,

Pipe RT Final FSK# 9700807 Weld #

Size Wall Thick.

Date UT & MT - Xl RT-428 Final "B" MS M-2040 1 -MS-72-FW-294 32" Min. 1.051 11/28/01 UT & MT Accept RT-405 "B" MS M-2040 1 -MS-72-FW-330 32" Min. 1.051 11/25/01 UT & MT Accept WP&IR # P-MSC-0001 MAINSTEAM "C" ASME Ill NC (CLASS 2)

Pipe RT Final FSK# 9700807 Weld #

Size Wall Thick.

Date UT & MT - XI RT-421 Final "C" MS M-2042 1-MS-80-288 32" Min. 1.051 11/28/01 UT & MT Accept RT-378 Final "C" MS M-2042 1-MS-80-310 32" Min. 1.051 11/25/01 UT & MT Accept

Preservice NDE Summary of New Piping Components WP&IR # P-FWA-0003 FEEDWATER "A" ASME III NC (CLASS 2)

Pipe RT Final FSK# 9700807 M-2000 Weld #

Size Wall Thick.

Date UT & MT - XI RT-452 Final "A"FW M-2000 1 -FW-FW-1 16" 0.688 12/02/01 UT & MT Accept RT-453 Final "A"FW M-2000 1-FW-FW-2 16" 0.844 12/01/01 UT & MT Accept RT-454 Final "A"FW M-2000 1 -FW-FW-3 16" 0.844 12/01/01 UT & MT Accept El..844 RT-455 Final "A"FW M-2000 1 -FW-FW-4 C/1 16" Pipe 1.129 12/01/01 UT & MT Accept El..844 RT-456 Final "A"FW M-2000 1-FW-FW-7 16" Pipe 1.129 12/01/01 UT & MT Accept WP&IR # P-FWA-0004 FEEDWATER "A" ASME III NC (CLASS 2) & B31.1 Pipe RT Final FSK# 9700807 M-2301 Weld #

Size Wall Thick.

Date UT & MT - XI Final RT-226 "A"FW M-2031 1 -FW-32-FW-494 16" 1.219 11/02/01 UT & MT Accept Final RT-225 "A"FW M-2031 1-FW-32-FW-493 16" 1.219 11/02/01 UT & MT Accept WP&IR # P-FWB-0003 FEEDWATER "B" ASME III NC (CLASS 2)

Pipe RT Final FSK# 9700807-M-2001 Weld #

Size Wall Thick.

Date UT & MT - XI RT-402 Final "B" FW M-2001 1-FW-FW-1 16" 0.688 11/25/01 UT & MT Accept RT-403 Final "B" FW M-2001 1-FW-FW-3 16" 0.844 11/25/01 UT & MT Accept RT-459 Final "B" FW M-2001 1-FW-FW-5 R/1 16" 0.844 12/01/01 UT & MT Accept RT-429 Final "B" FW M-2001 1-FW-FW-7 16" 0.844 11/28/01 UT & MT Accept RT-427 Final "B" FW M-2001 1-FW-FW-10 16" 0.844 11/2/01 UT & MT Accept WP&IR # P-FWB-0004 FEEDWATER "B" ASME III NC (CLASS 2) & B31.1 Pipe RT Final FSK# 9700807-M-2032 Weld #

Size Wall Thick.

Date UT & MT - Xl RT-321 Final "B" FW M-2032 1 -FW-36-FW-490 6"

0.432 11/16/01 UT & MT Accept Final RT-271 "B" FW M-2032 1 -FW-36-FW-488 16" 1.219 11/10/01 UT & MT Accept RT-255 Final "B" FW M-2032 1 -FW-36-FW-489 16" 1.219 11/08/01 UT & MT Accept 1 -FW-36-FW-499 C1-RT-354 Final "B" FW M-2032 R1 6"

0.562 11/21/01 UT & MT Accept

Preservice NDE Summary of New Piping Components S I RT-335 Final "B" FW M-2032 1 -FW-36-FW-500 C1 6"

10.562 11/18/01 UT & MT Accept WP&IR # P-FWC-0003 FEEDWATER "C" ASME III NC (CLASS 2)

Pipe RT Final FSK# 9700807-M-2002 Weld #

Size Wall Thick.

Date UT & MT - XI RT-443 Final "C" FW M-2002 1 -FW-FW-1 16' 0.668 11/30/01 UT & MT Accept RT-444 Final "C" FW M-2002 1 -FW-FW-2 16' 0.844 11/30/01 UT & MT Accept RT-445 Final "C" FW M-2002 1-FW-FW-3 16" 0.844 11/30/01 UT & MT Accept RT-446 Final "C" FW M-2002 1 -FW-FW-5 16' 0.844 11/30/01 UT & MT Accept RT-447 Final "C" FW M-2002 1 -FW-FW-7 16' 0.844 11/30/01 UT & MT Accept WP&IR # P-FWC-0004 FEEDWATER "C" ASME III NC (CLASS 2) & B31.1 Pipe RT Final FSK# 9700807-M-2033 Weld #

Size Wall Thick.

Date UT & MT - X1 Final RT-227 "C" FW M-2033 1-FW-39-4-FW-496 16" 1.219 11/03/01 Acc UT & MT Accept Final RT-228 "C" FW M-2033 1 -FW-39-4-FW-497 16" 1.219 11/03/01 Acc UT & MT Accept WP&IR # P-AFWA-0003 AUX - FEEDWATER "A" ASME III NC (CLASS 2)

Pipe RT Final FSK# 9700807-M-2006 Weld #

Size Wall Thick.

Date UT & MT - XI RT-457 Final "A" / M-2006 1 -AF-FW-1 6"

0.432 11/30/01 UT & MT Accept RT-458 Final "A" / M-2006 1 -AF-FW-2 6"

0.432 12/01/01 UT & MT Accept RT-462 Final "A" / M-2006 1 -AF-FW-5 6"

0.432 12/3/01 UT & MT Accept RT-284 Final "A" / M-2006 1 -AF-FW-6 6"

0.432 11/11/01 UT & MT Accept RT-464 Final "A" / M-2006 1 -AF-FW-8 Ri 6"

0.562 12/3/01 UT & MT Accept RT-463 Final "A" / M-2006 1 -AF-FW-9 6"

0.432 12/3/01 UT & MT Accept WP&IR # P-AFWA-0004 AUX - FEEDWATER "A" ASME III NC (CLASS 2)

Pipe RT Final FSK# 9700807-M-2006 Weld #

Size Wall Thick.

Date UT & MT - X1 Final RT-322 "A" / M-2030 1AF-18-2-FW-280 6"

0.432 11/16/01 UT & MT Accept

Preservice NDE Summary of New Piping Components WP&IR # P-AFWB-0003 AUX - FEEDWATER "B" ASME III NC (CLASS 2)

Pipe RT Final FSK# 9700807 M-2007 Weld #

Size Wall Thick.

Date UT & MT - XI RT-437 Final "B" / M-2007 1 -AF-FW-1 6"

0.432 11/29/01 UT & MT Accept RT-434 Final "B" / M-2007 1-AF-FW-3 6"

0.562 11/29/01 UT & MT Accept WP&IR # P-AFWB-0003 AUX - FEEDWATER "B" ASME III NC (CLASS 2)

Pipe RT Final FSK# 9700807 M-2007 Weld #

Size Wall Thick.

Date UT & MT - XI RT-431 Final "B" f M-2007 1 -AF-FW-5 6"

0.562 11/28/01 UT & MT Accept RT-285 Final "B" / M-2007 1 -AF-FW-6 6"

0.562 11/11/01 UT & MT Accept RT-470 Final "B" / M-2007 1 -AF-FW-8 6"

0.719 12/03/01 UT & MT Accept WP&IR # AFWB-0004 AUX - FEEDWATER "B" ASME III NC (CLASS 2)

Pipe RT Final FSK# 9700807 M-2007 Weld #

Size Wall Thick.

Date UT & MT - XI RT-270 Final "B"/ M-2029 1 -AF-1 4-FW 270 6"

0.432 11/10/01 UT & MT Accept WP&IR # P-AFWC-0003 AUX - FEEDWATER "C" ASME III NC (CLASS 2)

Pipe RT Final FSK# 9700807-M-2008 Weld #

Size Wall Thick.

Date UT & MT - XI RT-474 Final "C" / M-2008 1-AF-FW-1 -R1 6"

0.432 12/6/01 UT & MT Accept RT-475 Final "C" / M-2008 1 -AF-FW-2-R2 6"

0.432 12/6/01 UT & MT Accept RT-467 Final "C" / M-2008 1 -AF-FW-5 6"

0.432 12/3/01 UT & MT Accept RT-286 Final "C" I M-2008 1-AF-FW-6 6"

0.432 11/11/01 UT & MT Accept RT-473 Final "C" / M-2008 1-AF-FW-8 6"

0.562 12/05/01 UT & MT Accept WP&IR # AFWC-0004 AUX - FEEDWATER "C" ASME III NC (CLASS 2)

Preservice NDE Summary of New Piping Components Pipe RT Final FSK# 9700807-M-01 5 Weld #

Size Wall Thick.

Date UT & MT - XI RT-272/291 "C"/M-2028 FW-261 -R1 6"

0.432 11/11/01 Final LUT & MT Accept EQUIPMENT HATCH WP&IR

  1. C-EHX-0002 EQUIPMENT HATCH ASME III (CLASS NE)

Pipe RT Final FSK#

Weld #

Size Wall Thick.

Date UT & MT - ASME XI 24' 2 1.250 to RT-417 Final BKC-086 FW-1 1/2" 1.500 11/28/01 MT 11/29/01 Accept WP&IR # P-RCA-0001 RCS "A" ASME III NB (CLASS 1)

Pipe RT Final FSK# M-199 Weld #

Size Wall Thick.

Date UT & PT ASME XI 1 -RC-1 -FW-9 "A"

RT-297 Final "A" RCS-C/L M-199 HOT LEG 31" ID 2.48 11/13/01 UT & PT Accept 1-RC-1 -FW-10 "A"

RT-298 Final "A" RCS-H/L M-199 COLD LEG 31" ID 2.48 11/13/01 UT & PT Accept WP&IR # P-RCB-O001 RCS "B" ASME III NB (CLASS 1)

Pipe FRT Final FSK# M-200 Weld #

Size Wall Thick.

Date UT & PT ASME XI 1 -RC-2-FW-9 "B"

RT-306 Final "B" RCS-C/L M-200 HOT LEG 31" ID 2.48 11/14/01 UT & PT Accept 1 -RC-2-FW-10 "B"

RT-307 Final "B" RCS-H/L M-200 COLD LEG 31" ID 2.48 11/14/01 UT & PT Accept WP&IR # P-RCC-0001 RCS "C" ASME III NB (CLASS 1)

Pipe RT Final FSK# M-201 Weld #

Size Wall Thick.

Date UT & PT ASME XI 1 -RC-3-FW-9 "C"

RT-313 Final "C" RCS-C/L M-201 HOT LEG 31" ID 2.48 11/14/01 UT & PT Accept 1-RC-3-FW-10 "C"

RT-314 Final "C" RCS-C/L M-201 COLD LEG 31" ID 2.48 11/14/01 UT & PT Accept

SECTION 4 COMPONENT SUPPORTS

HNP RFO10 Report for ASME Section XI Component Supports and Snubbers Prepared by: Roger M. Winton Date: 1/17/02 In RFO10, the following activities were completed to satisfy ASME Code and Technical Specification requirements for component supports and snubbers. Certified VT Level II CP&L QC, VT Level II contractor QC and ISI VT Level III personnel performed the examinations.

Fifty-four scheduled ASME Section XI Component Support visual examinations were performed in RFO10. The examination results were all satisfactory except for one case of a displaced spherical bearing on hanger RH-H-159. The support remained operable with this discrepancy and the condition was corrected. The examination scope was expanded as a result of the visual failure to the adjacent supports and the similar supports on the opposite piping train. No other adverse conditions were observed.

Technical Specification 3/4.7.8, as implemented by procedures PLP-106 Attachment 4 and ISI-202, requires snubbers to be functional tested each outage. Mechanical snubbers are tested in the representative sample "37 Plan" and a separate harsh environment test group. In the representative sample, 37 snubbers were tested and no failures were observed. In the harsh environment test group, 36 snubbers were tested and there were 2 failures. The failures were a result of high drag (internal friction), but had freedom of motion. Test scope expansion is not required for these failures.

Hydraulic snubbers are tested by the "10% Plan". In addition, to comply with OM-4 requirements, the Steam Generator snubbers are a separate "10% Plan" test group. A total of 5 large bore hydraulic snubbers were tested. These tests all had satisfactory results.

Technical Specifications require 100% visual inspection of snubbers on a 36 month interval. During RFO 10, snubber inspections included those outside the Containment Bioshield wall and inside the Pressurizer cubicle. The SGR project limited access inside the S/G cubicles and the Bioshield wall. Of approximately 1400 mechanical snubbers and 39 hydraulic snubbers, 1057 were inspected. The remaining snubbers are to be inspected in RFOl.

HNP RFO10 Report for ASME Section XI Component Supports and Snubbers The snubber inspections resulted in the following observations:

- One loose cap screw on the attachment to a transition tube. The other 2 screws were tight and the loose screw was tightened.

- One spherical beating was displaced in its paddle. The bearing remained engaged in the paddle and was operable. The bearing was pressed back into position and staked per POM procedure MMP-004, Installation of Pipe Supports.

- One loose pipe clamp. The snubber functions in tension so the support was considered operable. The condition was corrected by tightening the pipe clamp.

- One snubber appeared to be discolored, possibly from heat. The snubber was tested and found satisfactory. A replacement snubber was installed.

- Two S/G hydraulic snubbers were observed with minor fluid leaks. The snubbers remained operable and were repaired by replacing the reservoir to body seals.

(

RFO10 ISI Exam List - ASME Section Xl Component Supports for Outage 2-2-10 Category F-A Item Fl.IOB Class 1 Hanger - Box Type Support Hanger Location Exam Type Exam Date Exam Results Examiner RH-H-1 51 Cont 234' R-35' Az-339 VT-3 9/25/01 PASS SAB Category F-A Item Fl. 1 OR Class 1 Hanger - Rigid Support Hanger Location Exam Type Exam Date Exam Results Examiner CS-H-2870 Cont 255' R-40' Az-130 VT-3 9/24/01 PASS SAB RH-H-149 Cont 234' R-22' Az-1 39 VT-3 9/24/01 PASS SAB RH-H-1 53 Cont 230' R-48' Az-339 VT-3 9/24/01 PASS SAB SI-H-433 Cont 250' R-41' Az-7 VT-3 9/24/01 PASS SAB SI-H-941 Cont 254' R-47' Az-21 0 VT-3 9/24/01 PASS SAB Category F-A Item Fl.1OV Class 1 Hanger - Variable (Spring Can) Support Hanger Location Exam Type Exam Date Exam Results Examiner SI-H-427 Cont 258' R-33' Az-5 VT-3 9/24/01 PASS SAB Category F-A Item F1.20A Class 2 Hanger - Anchor Hanger Location Exam Type Exam Date Exam Results Examiner CS-H-18 RAB 249' COL 29 4'E/E VT-3 9/29/01 PASS JS/LM Category F-A Item F1.20R Class 2 Hanger - Rigid Support Hanger Location Exam Type Exam Date Exam Results Examiner CS-H-24 RAB 254' 2'S/26 11 'E/E VT-3 9/28/01 PASS JS/LM CS-H-29 RAB 248' 11 'S/36 3'W/D VT-3 9/28/01 PASS JS/LM CT-H-219 RAB 221' 9'N/20 4'E/E VT-3 9/28/01 PASS PP Page 1

(

C Category F-A Item F1.20R Class 2 Hanger - Rigid Support - continued Hanger Location Exam Type Exam Date Exam Results Examiner CT-H-819 RAB 207' 1'S/20 4'W/FV VT-3 10/13/01 PASS HAG RH-H-59 RAB 195'1 'S/34 8'E/FV VT-3 9/29/01 PASS SHS RH-H-1 59 RAB 223' 2'S/36 4'W/E W/R 28863 VT-3 9/28/01 FAIL SAB Category F-A Item F1.20V Class 2 Hanger - Variable (Spring Can) Support Hanger Location Exam Type Exam Date Exam Results Examiner CT-H-293 RAB 193' 2'N/34 10'W/FV VT-3 9/28/01 PASS SHS Category F-A Item F1.30A Class 3 Hanger - Anchor Hanger Location Exam Type Exam Date Exam Results Examiner CE-H-25 RAB 252' 3'N/1 3 18'W/B VT-3 9/28/01 PASS JS/LM CH-H-1467 RAB 272' 11 'S/23 4'W/E VT-3 7/17/01 PASS JS CX-H-361 RAB 263' 3'N/36 3'W/C VT-3 7/16/01 PASS JS SW-H-1227 RAB 238' 5'N/26 12'W/B VT-3 9/28/01 PASS JS/LM SW-H-1289 RAB 237' 8'S/39 3'W/D VT-3 9/28/01 PASS JS/LM Category F-A Item F1.30B Class 3 Hanger - Box Type Support Hanger Location Exam Type Exam Date Exam Results Examiner AF-H-30 RAB 274' 4'S/27 2'W/D VT-3 7/18/01 PASS JS CH-H-284 RAB 253' 3'N/36 5'W/C VT-3 10/12/01 PASS HAG SW-H-56 RAB 228' COL 27 9'E/FZ VT-3 9/28/01 PASS SHS SW-H-547 RAB 227' 9'N/41 5'W/D VT-3 10/5/01 PASS JS/KH SW-H-1607 RAB 237' 5'S/39 3'W/D VT-3 10/15/01 PASS HAG Page 2

(.

Category F-A Item F1.30R Class 3 Hanger - Rigid Support Hanger Location Exam Type Exam Date Exam Results Examiner AF-H-1 60 RAB 250' 2'N/28 4'W/B VT-3 9/28/01 PASS JS/LM AF-H-261 RAB 269' COL 28 16'W/B VT-3 7/16/01 PASS JS CC-H-90 RAB 250' 7'N/1 8 3'E/C VT-3 9/28/01 PASS JS/LM CC-H-309 RAB 230' 7'S/32 COL FX VT-3 9/28/01 PASS SHS CC-H-877 RAB 250' 1'S/i 8 9'W/C VT-3 10/16/01 PASS HAG SF-H-435 FHB 247' 9'N/36 13'W/L VT-3 10/12/01 PASS JS/KH SF-H-486 FHB 243' 12'N/41 6'E/N VT-3 10/12/01 PASS JS/KH SW-H-68 RAB 228' COL 29 8'E/FZ VT-3 9/28/01 PASS SAB SW-H-114 RAB 223' 8'N/32 COL FX VT-3 9/28/01 PASS PP SW-H-509 RAB 248' 6'N/1 5 COL D VT-3 9/28/01 PASS JS/LM SW-H-612 RAB 230'1 'S/20 8'E/FV VT-3 9/28/01 PASS SAB SW-H-1 297 RAB 251' 5'S/31 3'E/D VT-3 9/28/01 PASS JS/LM SW-H-1 310 RAB 237' 5'S/28 9'W/B VT-3 9/28/01 PASS JS/LM SW-H-2598 RAB 227' 1 4'S/73 5'W/D VT-3 10/5/01 PASS JS/KH SW-H-2686 RAB 250' 20'N/74Y 1 0'W/CZ VT-3 10/5/01 PASS JS/KH Category F-A Item F1.30V Class 3 Hanger - Variable (Spring Can) Support Hanger Location Exam Type Exam Date Exam Results Examiner CC-H-904 RAB 238' 8'S/1 8 6'W/B VT-3 9/28/01 PASS JS/LM CE-H-9 RAB 249' 5'N/27 15'W/B VT-3 9/28/01 PASS JS/LM SF-H-1308 FHB 239' 4'S/42 14'E/N VT-3 10/12/01 PASS JS/KH Page 3

K

(

Category F-A Item F1.40 Class 1, 2 and 3 Equipment Supports Component Location Exam Type Exam Date Exam Results Examiner Cont Fan Cooler AH-2 Cont 236' R-58' Az-120 VT-3 9/24/01 PASS SAB II-AH-002A-H-001-031 31 examination points CSIP B Oil Cooler RAB 236' 5'S/31 10'E/E VT-3 10/12/01 PASS HAG lI-CPOC-1B-H-001-002 2 examination points Pressurizer 1X-SN Cont 261' R-35' Az-310 VT-3 9/27/01 PASS DM II-PZR-01H-001-032 32 examination points Volume Control Tank 1X-SN RAB 261' 10'S/31 9'E/E VT-3 10/15/01 PASS HAG lI-VCT-01 H-001-010 10 examination points Category D-A Item D1.20 Class 3 Welded Pipe Attachments Hanger Location Exam Type Exam Date Exam Results Examiner CC-H-8771(1)

RAB 250' 15'S/18 9'W/C VT-1 10/16/01 PASS HAG CC-H-8921(2)

RAB 250' 15'S/18 1 'E/C VT-1 10/20/01 PASS HAG CC-H-9061(4)

RAB 248' 2'S/1 8 7'W/D VT-1 10/15/01 PASS HAG CH-H-1 4671(2)

RAB 272' 11 'S/23 4'W/E VT-1 7/17/01 PASS JS CX-H-3611(2)

RAB 263' 3'N/36 3'W/C VT-1 7/17/01 PASS JS SW-H-561(4)

RAB 227' 3'N/43 5'W/D VT-1 9/28/01 PASS SHS SW-H-12271(1)

RAB 238' 5'N/26 12'W/B VT-1 9/28/01 PASS JS/LM Page 4

SECTION 5 NIS-2 FORMS

Class 1 WR/JO NUMBER TAG ESR NUMBER ASME CODE CLASS REPAIR OR REPLACEMENT 88074 1SI-356 NA 1

REPLACEMENT 88293 RC-H-59A NA 1

REPLACEMENT 88294 RC-H-59B NA 1

REPLACEMENT 88298 RC-H-920 NA 1

REPLACEMENT 88620 1 RC-125 NA 1

REPLACEMENT 88662 1 RC-RCPC NA 1

REPLACEMENT 89751 1 RC-RCPB NA 1

REPLACEMENT 104657-03 1 RC-H-236 NA 1

REPLACEMENT Page 1

WO# 88074 R/R# 01-01-005 ASME Xl, CLASS 1 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Carolina Power & Ligqht Company P.O. Box 1551. Raleiah. N.C. 27602-1551 Address
2. Plant Shearon Harris Nuclear Power Plant Name P.O. Box 165. New Hill. N.C. 27562-0165 Date 10/29/01 Sheet 1 of 2 Unit 1 W0# 88074 Address
3. Work Performed By Carolina Power & Light Company Name Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp N/A Authorization No. N/A

4. Identification of System SI - Safety Injection 5

(a) Applicable Construction Code ASME Section III 1974 Edition, Winter 74 Addenda, See Ni Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacement 1989-

, Addenda N/A

6. Identification of Components Repaired or Replaced and Replacement Components
Repaired, ASME Code Name of Name of Manufacture National Other Year
Replaced, Stamped Component Manufacture Serial No.

Board No.

Identification Built Or Replacement (Yes or No)

Stud Unknown NA NA Part# 763-315-74 Unknown Replaced Yes Stud REC Corp.

NA NA HT# 6L4612 Unknown Replacement Yes

7.

8.

Description of Work: Replaced stud on valve 1SI-356.

Tests Conducted: Hyrostatic El Pneumatic E] Nominal Operation Pressure El Other E] Pressure _

psi Test Temp.

-°F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2 in. X 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet in numbered and the number of sheet is recorded at the top of this form.

WO# 88074 R/R#.01-01 -005 ASME XI, CLASS 1 FORM NIS-2 (Back)

9. Remarks VT-1 pre-service exam performed on replacement stud. VT-3 inservice inspection performed on Applicable Manufacturer's Data Reports to be attached.

valve internals. Replacement stud was removed from indentical new valve from stock.

N 1 - See N-5 Data Report for Code Cases.

CERTICATION OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code,Section XI.

repair or replacement Type Code System Stamp N/A Certificate of Authorizati No. N/A Expiration Date N/A Signed

  • er e

e iui ment Performance Sulervisor Date../{oLL nbwneres esigne, itle CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of One State Street, Hartford, Connecticut 06102 have inspected the components described in this Owner's Report during the period of 05-13-00 to 12-14-01

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certification neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or Ororierty damage or a loss of and kind arising from or connected with this inspection.

________________________Commissions

-t/e711*K.,

i

  • "pector's Signature National Board, State, Province, and Endorsements Date______________

(12/82)

WO# 88293 R/R# 01-01-042 ASME XI, CLASS 1 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner Carolina Power & Light Company P.O-Box 1551. Raleiah. N.C. 27602-1551 2.

Address Plant Shearon Harris Nuclear Power.Plant Name P.O. Box 165, New Hill, N.C. 27562-0165 Address

3. Work Performed By Carolina Power & Light Company Name Date 10/15/01 Sheet 1 of 2 Unit 1 We# 88293 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp N/A Authorization No. N/A'

4. Identification of System RC - Reactor Coolant 5

(a) Applicable Construction Code ASME Section III 1974 Edition, Winter '76 Addenda, See N1 Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacement 1989 Addenda N/A

6. Identification of Components Repaired or Replaced and Replacement Components
Repaired, ASME Code Name of Name of Manufacture National Other Year
Replaced, Stamped Component Manufacture Serial No.

Board No.

Identification Built Or Replacement (Yes or No)

Snubber Pacific Scientific 37358 NA RC-H-59A 1985 Replaced No Snubber Pacific Scientific 15172 NA RC-H-59A 1980 Replacement No

7. Description of Work: Repalced snubber on hanger RC-H-59A.
8. Tests Conducted: Hyrostatic E] Pneumatic E] Nominal Operation Pressure E]

Other E] Pressure ___psi Test Temp. _____F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2/2 in. X 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet in numbered and the number of sheet is recorded at the top of this form.

WO# 88293 R/R#

1-01_-042 ASME XI, CLASS'1 FORM NIS-2 (Back)

9. Remarks VT-3 performed on hanger after snubber replacement.

Applicable Manufacturer's Data Reports to be attached.

N1 - See N-5 Data Report for Code Cases CERTICATION OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the repair or replacement ASME Code,Section XI.

Type Code System Stamp N/A Certificpte.of Authorization A. N/A Expiration Date N/A Signed

}-),,,*,w A~4--Equigment Performance Sulervisor Date J9!/5/-!O /

-Zw~ne5 b.mer's -Designee,*/l CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of One State Street. Hartford, Connecticut 06102 have inspected the components described in this Owner's Report during the period of 05-13-00 to 12-14-01

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certification neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of and kind from or connected with this inspection.

Commissions S rfrspector's Signature National Board, State, Province, and Endorsements Date _

_'0_____

(12/82)

FOR~M NF-I NPT CERTIFICATE HOLDERS* DATA REPOPT F A-, Rquire~d by the Provisions of the ASME Code Rules

'77 Grinnell C6rtiz,'21 Danz~ Street11 44(NO*"'Mu

  • ¶O 0,010 of

.cts 1'~ ~

3 Locat-on of 11'stIi3lf 4

(W.nl.ficstl'

4) ci-Cd svol R~pgqTfl'on D's-ngs -. M cc Lzoaa Caoa-Corml 1 N
o.

Lii: Reý~ & Z:e4-CSv ;arm Sh~eer Svc

__)

cýe]dlS4-'12 C.

L NETSUPPORTS*'"

Division I

__92e03 seOhio 448 19) sc Veaf audtf L

i930

0) te I (5;-
101 cEP'flFiCA TE CF CQ'SPUANCE

&IV.e Ey 0,a :e

!or t

a3c

$a, ar~

'a-

~~.

'4 v

Ale
-.P Zqa~l a

I,.

CERT'F)CATION OF DESIGN

~ L..Z Cd ~'t S ____________________DESIGN___

a:S

t.

or.

2za

-~~ac r

o a y

'ý a 7

,sY LS6ý Ca*4..

P1Y I

C.

J I

y~)~a'.'*"G 7ha fa-mn iZVC-- ýA t.. zt;.ACf-e Nr,- 1e CrAeZe (Corel

.e:~

s fr:

nc c.s)SOR.:acý a~~-s-i-~

(71-45 ---. 47:ý S, N.Y.

-Cl; 6-s-it

.-ýr J-z %SO r C 4% JAAZtC-1 S-W jOw JC&;40%-

&%4. jaý1!44 a,*

S LCC4--

T.If:

A-.;w t2jr,;.;

2,kC:0-a 9,.

10 l3acsV1.2q. ;au:,aý It C'. Stý d-. J,%. ;J-K

ýT a50#!-'Jw% L-ic ;saq xý;
-t A-C ID a*;l V.

LOU SLL;ajt e;re:: Se :%,7-ajQj SLj2C z6_

-A4

aAD)C-2 PUr owe.*;.02 ý0 P.O.1ct. 3-,4*. Ný vo-ss-ý-C
p P-ýV-r NOUD3eSNI 0-13IN 30 N0I.IVDti!IV3:)

.ýv

$t.

A.v 3ý0.S-0-.C3 a,;.

-Z.C-ýw.

-ý.r

'ass A _r::

43, pajDauuC3 Ja 4.uo.,; 501slie PJ!ý Aut jib not r ;6. a5e--;e,- ý,L,,ýrjox to Ainfu

.Ui j

aW. ;41;114L:

'LAOC;ld ?,rc SIL;*. U, ýaqljnap S114 '0ý '6' ads

`6.a--ALSt,)t-Avt SaIrU, jaAOICJUja VI OU 00040SUI aul aw-au 'alt.:1-joloaý1 S.t4j tju4uO0UP0: lucid Jamcd J!ZID^N oOi 0::'0:) BINS V lsw03 Igr4j ýaDjom N)r:p.#rIj4D !dN 0-4: Jý60ýq Pur aap.Niýow% Aw to ISO-C ý,..

m It,43 airls O.'s F &to sm I W.

a r. % WC-0 0 -% Iw-.00 W" aw. pa otac so k b. t 4 Aq PbAO10U..# Put t oa.1.09 ;0 proq jtw0qVpj 3,,41 Aq C.Onjjý_UOJ911WU;Cý PIIA I 'ý,OfOj NOIJZ)3dSNI dDHS ýO 3-!V:)HIIkI33 ON OwV '

'O'd

'31 Aae jr,; jajue-j.; Aue ur alQPq M Pa. 11 jo &gifts ai: I>Vr L

01DWO) L-.iN WHO:1

4 FORM NP.1 IJPT CERtTIFICATE HOLDEflC OATA atpORTF OR~ COMPONENT SUPPORTS' As Rilquired by ti. Provihions of the ASME Cod* Rul", Soction 1t1, D1vislson 1

1. Monufamufe1 3y2e 14,6 S. Stato-Cj.13m0yd. Anhim,_Ca_9. 03 I. Mnuf~lufd b,.Jft~i+/-C~~A~8l~Uf4Q(Nam; anýd aiddtets; oif NPT Cietfllflal. H

. Anoo SoUthWoadt 1Abrlcat~tifg=ýfit 71

2. MN~lfff Wolding Co.# Inc. r'.O. fox -9449 llouat.ot-n, Taxc

~ 771 M~asciu lyi'~Videe, Inc.

IN aitag.. fl~

f1W I~clear Plants Agents for Carolina' Power & Light iwiJ~Wk. qnyN.a9.il

3. Locationt of Installation fl..l

-ak QUnt

,_j_,

A. Identificationi Cof"Pelonnt Canadian Applicable Strait Repolt Typo of Supipof k A09111tition Diawvingi-with Or tjad Capa-Compnflatnt N~itt' fi~rtt 1 1) No.

No L*4t Rev & Ovta c'ity Data Shoot Supportt

.i Ni year Omtit m82O849--V 1801101-ýS-J DR-1351-Linaar I

N~one 1979 (21 Rev. A (4)~

CET(CT F

OPLAC Wecriyta(6 ttm nsm1s nti w

t r

orc n

ta hs o pnnsspot onomt h

ue fcntuto ofte(7 oefrN cetPo" lin

m oet.Scin[t iiio

.Clto 7

1v(j s m e 7

CoeCs(o._8 4-G.__1._

Out teASME Codifae tr N(if a l'oth tp.iltat Cwopf~

i SNoti I

ll iis*"

tile (iiiiAditl

~ a'~

r 7

CodX~fe xpiresN..,.1644E.

4 931 oaT/~~~(

~

ureacific Scientific-L A/';

Deuir ASMI Cattione it Aet.,fth~uztivy VI, State il hr (nl I

.8~j 1

O RAug No 13531 Symb iis nlit feot.

,L a

aoiyD l

Soi;tv(

e A

CETIIATO 04,l OESol Stre. 4g eoi rtthis Data Reriaiii is Data Sht et o ur va I shqur an 3

-ci h e sfu betdnl utt r(fslvi sf(Cretfttl thcisform i~liIi Filed form iCO0A5 3m5y leo owan. fro thei Ore ow Sf-35E hS..NwYok

.Y 01 I I - I I I

FORM NF-1 (Back)

CERTIFICATE OF SHOP INSPECTION I. file undei'igned. holding 9 valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or ProvincrOf T

dWYork and employed by HSBI& I Co.

of Hartfr 9d4 CT have nspected Ihe component supports described in this Data Report on 19 **--

1d stAle Mrat to !he best of my knowledge and belief the NPT Certificate Holder has constructed these cutriunent Supporfts n ac.ordance with the ASME Code for Nuclear Power Plant Components.

By signing thi-certificate, neither the Inspector nor his employer makes any warranty, expressed or implied. concerning the component supports described in this Data Report. Furthermorc. neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Date-Signed

~

Commissions (Nal d State. P1o`

. and No)

CERTIFICATION OF FIELD INSPECTION I. the undersigned, holding a valid commission issued by the Nalional Board ol 8oiler and Pressure Vessel Inspectors and the State or Province of__

and employed by_

of._

S.....

have compared the statements in this Data Report with the described component supports and state that the parts referred to as data items not included in the.erlificate of shop inspeclion, have been....

inspected by me and that to the best of my kno-ie0dge and tw*ei ihi NPT Certtiiat, Hid,-r ha% c*,nstru,.td Ihtu.in.i....*onent suoports in Accord.

ance with the ASME Code for Nuclear Power Plant Components.

By signing this certificate neither the Inspector nor his employer makes any warranty. expressed or implied, concerning the component supports desFribid in this Ota Report Fu-thermure. neither tre ins0ceC(,r nA. hS em0Irye'r small be liable,n.Ceemal

~

ails O4ir*)tlJ injury or property damage or a loss of iin kind arising from or ccnnecteo rth

!his insoeLtlson Date-.

Signed -

Com miss,o

-s-..........

cNat'" 1O Stale. Pov and No.t

WO# 88294 R/R# 01-01-081 ASME XI, CLASS 1 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Carolina Power & Light Company P.O. Box 1551, Raleigh, N.C. 27602-1551 Address
2. Plant Shearon Harris Nuclear Power Plant Name P.O. Box 165, New Hill, N.C. 27562-0165 Address
3. Work Performed By Carolina Power & Light Company Name Date 11/06/01 Sheet 1 of 2 Unit 1 WO# 88294 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp N/A Authorization No. N/A

4. Identification of System RC - Reactor Coolant 5

(a) Applicable Construction Code ASME Section !11 1974 Edition, Winter '76 Addenda, See N1 Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacement 1989

, Addenda N/A

6. Identification of Components Repaired or Replaced and Replacement Components
Repaired, ASME Code Name of Name of Manufacture National Other Year
Replaced, Stamped Component Manufacture Serial No.

Board No.

Identification Built Or Replacement (Yes or No)

Snubber Pacific Scientific 37230 NA RC-H-59B 1985 Replaced No Snubber Pacific Scientific 14678 NA RC-H-59B 1980 Replacement No

7. Description of Work: Replaced snubber on hanger RC-H-59B.
8. Tests Conducted: Hyrostatic El Pneumatic El Nominal Operation Pressure El Other E] Pressure __psi Test Temp.

!?F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2 in. X 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet in numbered and the number of sheet is recorded at the top of this form.

WO# 88294 R/R# 01-01-081 ASME Xl, CLASS 1 FORM NIS-2 (Back)

9. Remarks VT-3 performed on hanger after snubber replacement.

Applicable Manufacturer's Data Reports to be attached.

N1 - See N-5 Data Report for Code Cases CERTICATION OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the repair or replacement ASME Code,Section XI.

Type Code System Stamp N/A Certificate of Auth orizatio No. N/A Expiration Date N/A Signie d 7T'i'111 7, Fuipment Performance Supervisor Date 0

Owner r Owners esign Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of One State Street. Hartford, Connecticut 06102 have inspected the components described in this Owner's Report during the period of 05-13-00 to 12-14-01 and state that to the best of my knowledge and belief, the Owner has performed examinationsand taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certification neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of and kind arising from or connected with this inspection.

Signature Commissions

.--) C

,2..

d ispector's Signature National Board, State, Province, and Endorsements Date,-,e/

(12/82)

FORM NF-1 NPT CERTIFICATE HOLDERS' DATA REPORT FOR COMPONENT SUPPORTS' As Requlred by the Provisions of the ASME Code Rules. Section lU. Division I 1

f+

  • . M*u*,

Pacific Scintfic 1346 S. State.Col1eqe Blvd...t udai~m, California 92803 "mt.ulacturor for, I

T G nel.o Cooratinn

+621 Dna Street N.E. Wur-en, Cbio 44481

3. Location of Installation TInkrJY'-

4, Identification C an (b!

Canidan Rernatratlon (D,9 Orawinas eSw it"I (d)

Stress Report or Load Cava-(e)

Type of Compnonent (f)

Bga Nat'i 8oard (h)

1

.6

.1

'I.

CERTIFICATE OF COMPLIANCE We certify that the statements ma*a in this report aWe correct and that trheo cornoonents supports Conform to the rules of construction

.. of tiie ASME Code for Nuclear Pow*r P.ant Components. Section II1, Division 1, Edition, 197

. Addenda Wintp' 177 Code Case No.

W4-

_____________lf~Y oatel a is q I Isigned Pacific Scientific

-~~(P cetiict a.+i.,,

e..,,o+

Our ASME Cftificate of Authorization No.

1198 to use INPTI Symwo eapires -.

uq.

4, 1981 (Oats?

CERTIFICATION OF DESIGN Design Information on File at Pacific Sciemtific Stress Report or Load Capacity Data Sheets on File at' Filed Per,A 3256

.Desgn SoecitAfcaons Certified t, (1I Leo E. AV PS State Ca3ifcrý-ia Reg. No.

13533 Stress Analysis Report or Load Capacity Data Sheet$ Certified by (1 Te.Ay PE State-cai 5r~ia A49. No r-11

".Suplemental sneets in form of lsts. sketc.ies or drawings may be used orovideJ Mti sizes 8a in. (2) information in,erns 1 2.

/

4.c. 4g on this Oats Reoo*,s included on eacr sneet. and 13) each sheet is numbered and nurnoer of sheets is recorded at tQP o0'*.

"!1s43 form (1077 This form I E000751 mav be obtaited from the Order Neot.. ASME, 345 E. 47th St.. New York. N.Y. 10017 V-I

1. 0. No.

No.

Last Rev. & Oatt City Oats Sheet Support Clau No.

Year Built S14582-14681 No 1801104-05-J DR-1348-Rev. B Linear 1

e 1980 q2)

(3) 441

15) l6)

(7)

(81 (91 (10)

5. Remarks:

2.

t echesof of a-A44I

(-&Me and a-t"s 0

ou

S S-i

-I

  • 1 Cl ji..

1?

-I o *2

  • i FORM NF-1 (Back)

CERTIFICATE OF SHOP INSPECTION i,

1. the underignead, holding a valid comm'isOn isaued blV the National 9oar 4 of Boder and Pres1ure Vessell Insoector, and the State or P.ovinCe Of a1f~f.~

and empoloved bpy.........--FB&

of.

'?

/A

=

have inSoectid the componenlt suoorsll described in Itis$ Oats Regal'S oran

,7 "and..

sVale that to the best ol my knawledlo and bflief the NFT Celllflcale Moldier #iSA constructed these comoonent luooorts In accordance iwith the ASME Code f' Nuclear Power Plant Components.

By Signing this certificate, neither the inspc*co' nori his cmioloVer make5 any warranty, exOressed or imolied. concefning the componiint

%uppOrtS described in this Data Report. Furthermore, neither the Inspector nor his employer s,="all be liable in any manner for any personal inlury or property damage or a loss of any kind arising from or connece.ed with this inspection.

S ig n e d

~

itiq/..S-'.

P~jC C o m m is s io n s 7'

(Nati, ad.. St~ate. Pr 0,,. and No I

CERTIFICATION OF FIELD INSPECTION

i. the undersigned. holding a vahid cor mition issued by the National Soard of Boiler and Pressure Vessel Inspectors and :he State or Novqnca of and erno'oiv.d by df have compared the statements in this Data Report with the described component suporos and state I that the parts re ferred to as data items not included in the certificate of shop insoection. have been Insoeclttd by me and Mnat to the best of my sntowiedge and belief the,apy Certificate moOer has constructed these comoonent suotoOts in accord arce With the ASME Code for Nuclear Power Plant Components.

By signing this certificate neither the Inspector nor his emoloyEr makes any wartranty. expresued or implied, concerning the cornoonent sueorls described in tins Dita Aego't. FurthermOre. neither the ns$OectOr nor his eomnoret shall be ciaote in any manner #or any

-efsonai injury or erooeftl damage or a loss of any kiind arising from or Connected with t.iS.$SoeCtioii.

Date Signed Commissions Iii V

liii.

WO# 88298 R/R# 01-01-039 ASME XI, CLASS 1 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner Carolina Power & Light Company 2.

P.O. Box 1551, Raleigh, N.C. 27602-1551 Address Plant Shearon Harris Nuclear Power.Plant Name P.O. Box 165, New Hill, N.C. 27562-0165 Address

3. Work Performed By Carolina Power & Light Company Name Date 10/16/01 Sheet 1 of 2 Unit 1 WO# 88293 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp N/A Authorization No. N/A

4. Identification of System RC - Reactor Coolant 5

(a) Applicable Construction Code ASME Section III 1974 Edition, Winter '76 Addenda, See N1 Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacement 1989

, Addenda N/A

6. Identification of Components Repaired or Replaced and Replacement Components
7. Description of Work. Replaced snubber on hanger RC-H-920.
8. Tests Conducted: Hyrostatic [] Pneumatic L] Nominal Operation Pressure 5 Other E] Pressure ___psi Test Temp. _

-F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 811/2 in. X 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet in numbered and the number of sheet is recorded at the top of this form.

Repaired, ASME Code Name of Name of Manufacture National Other Year
Replaced, Stamped Component Manufacture Serial No.

Board No.

Identification Built Or Replacement (Yes or No)

Snubber Pacific Scientific 15649 NA RC-H-920 1981 Replaced No Snubber Pacific Scientific 8775 NA RC-H-920 1979 Replacement No

_ I _

_ I _

_ I _

1

_ 1 4-4 4

4 4

4-4-

4-4 4

4 4

+

4 4-4 4

4 4

+

4 4-4 4

4 4

+

4

WO# 88298 R/R# Q1-01-039 ASME Xl, CLASS 1 FORM NIS-2 (Back)

9. Remarks VT-3 performed on hanger after snubber replacement.

Applicable Manufacturer's Data Reports to be attached.

N 1 - See N-5 Data Report for Code Cases CERTICATION OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the repair or replacement ASME Code,Section XI.

Type Code System Stamp Expiration Date N/A Date 101,l CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of One State Street, Hartford, Connecticut 06102 have inspected the components described in this Owner's Report during the period of 05-13-00 to 12-14-01

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certification neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or prop3erty damage or a loss of and kind arising from or connected with this inspection.

_ C om m issions,/,

,,I

  • Inspector's Signature National Board, State, Province, and Endorsements Date (12/82) tt',Fn,.inrnont Davfnn,,onnn 0.

N/A

WO# 88620 R/R# 01-01-065 ASME XI, CLASS 1 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner Carolina Power & Lioht Comnanv 2.

p fl R'w 11 P,lLehI, M C' G7A)AJL1 e*

v

  • ..I

/

  • '.'JlI I UifL.lIt.4I** I****U.

t-FUf-J..'

LL Address Plant Shearon Harris Nuclear Power Plant Name P.O. Box 165, New Hill, N.C. 27562-0165 Address

3. Work Performed By Carolina Power & Light Company Name Date 01/04/02 Sheet 1 of 2 Unit 1 WO# 88620 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp N/A Authorization No. N/A

4. Identification of System RC - Reactor Coolant 5

(a) Applicable Construction Code ASME Section Iii 1974 Edition, Winter '76 Addenda, See N1 Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacement 1989

, Addenda N/A

6. Identification of Components Repaired or Replaced and Replacement Components
Repaired, ASME Code Name of Name of Manufacture National Other Year
Replaced, Stamped Component Manufacture Serial No.

Board No.

Identification Built Or Replacement (Yes or No)

PZR Safety Valve Crosby Valve & Gage N56964-00-0050 222 PN# 728-527-67 Unknown Replaced Yes Company PZR Safety Valve Crosby Valve & Gage N56964-00-0088 374 PN# 728-527-67 Unknown Replacement Yes Company

7. Description of Work: Replaced PZR Safety valve 1 RC-1 25.
8. Tests Conducted: Hyrostatic El Pneumatic E] Nominal Operation Pressure [

Other E] Pressure

__psi Test Temp.

-2F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2 in. X 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (8) each sheet in numbered and the number of sheet is recorded at the top of this form.

WO# 88620 R/R# 01-01 -065 ASME XI, CLASS 1 FORM NIS-2 (Back)

9. Remarks VT-2 performed after valve replacement.

Applicable Manufacturer's Data Reports to be attached.

N1 - See N-5 Data Report for Code Cases CERTICATION OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the repair or replacement ASME Code,Section XI.

Type Code System Stamp N/A Certificate of Authoriz No.

Signed nedý,-,

,&wne rOwner' Deys!

N/A Expiration Date N/A

.r1.-Eauipment Performance Supervisor Date 1/4/02 b, Title (12/82)

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of One State Street, Hartford, Connecticut 06102 have inspected the components described in this Owner's Report during the period of 05/13/00 to 12/14/01

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certification neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of and kind arising from or connected with this inspection.

Commissions NC 1444 NIAB Inspector's Signature National Board, State, Province, and Endorsements Date C> 72

CROSBY S91, :V-ANLV AM,

-A It ENTH AM, M ASS FORM NV-I FOR SAFETY AND SAFETY RELIEF VALVES Q.C.-44C As required by the Provisions of the ASME Code Rules DATA REPORT Safety and Safety Relief Vslves

1.

Manufactured By Crosby Valve & Gage Co.,

43 Kendrick St., Wrentham, MA 02093 Name and Address Model No..

LBBP 8 ýrder No t3017 Contract Date ational Board No 374 astinghouse Electri Corp., Nuclear Energy Systems

2. Manufactured For P.-O Box 355, Pittsburgh, PA 15230 Order No.

546-CCK-178367-BN Name and Address

3. Owner Carolina Power jJ, tt o...S*

on Harrih Not.

har__.1,zr__pE sqt #-I Name and Addiess

4. Location of Plant
5. Valve Identification 6RV8_MSB Serial No.IN56964-00-0088 Drawing No

.Rev.

Type Safety Orifice Size ______

Pipe Size Inlet 6,_* Outlet 6

Safety.Safety Relief. Pilot. Power Actuated Inch Incb Inch Inch

6. Set Pressure (PsIG) 2485 650 F

Ra, V Temperature Stamped Capacity 420006 LBS./HR. SAT.

3

__6. Overpes sure __

Blowdown (PSIG)

Hydrostatic Test (PSIG) Inlet __

4 5

Complete Valve 750 PSIG

7. The material, design, construction and workmanship comply with ASME Code. Section I11.

Class 1

Edition.

1971 _Addenda Date Winter 1972

,Case No.

Pressure Containing or Pressure Retaining Components Serial No.

Material Specification

a. Castings Identification Including Type or Grade 43ody N90490-44-0100 ASME SA182 Gr. F316 Bonnet N90353-44-0115 ASME SA105
b. Bar Stock and Forgings Holder K57220-42-0098 Nozzle Disc K57220-42-0098 Spring Washers Adjusting Bolt Spindle K56381-44-0138 N90553-47-0112 N90555-45-0102 N90349-47-0131 N90350-42-0255 N90350-40-0238 N90351-43-0132 N90354-46-0 1 32 ASTM A637-70 Gr. 718 ASME SA637 Gr.

718 ASME SA182 Gr. FnI6 Haynes Stellite Alloy #6B

-IFA 70 Gr.

B6 ASME SA193 Gr.

B6 kýMfq 7 'Gr B

Tvp 0

3 ýA 7 34,? -/_3

Serial No. or Identification NIX2761-0147 Vatterial S3pecificstion Including Type or Grade ASTH AIQ4 5IR60fH

d. Bolting
e. Other Parts such as Pilot Components STUD N90488-1232 thru 1243 ASME SA453 Gr.660 NUT

.NO04Q-127_. bru 1 18 ASTM A193-70 Gr. B6 We certify that the statements made in this report are correct.

Date 2"-6__ 19 7 2 Signed Crosby Valve & Gage Co. By Manufacturer 926 October 28, 1977 Certificate of Authorization No.

___________expires CERTIFICATE GF SHOP ENSPECTION I1 the undersigned, holding a valid commission issued by the tauonal Board of Boiler and Pressure Vessel Inspectors and the State or Province of kass.

and employed by Fact-nry Mutl-i,;1 qSv*-pmq*,

Norwnnid.. Mass.

.have inspected the equipment described in this Data R'i"'rt on and state that to the best of my knowledge and belief. !he Manufacturer *has constructed this equip ment in accordance with the aeplicable Subsections of ASME Section III.

By signing this certificate, neither the Inspector nor his employer makes any warranty, ex pressed or implied. corcerning the equipment described in this Data Report.Furttwermore.. neither the Inspector nor his eripl!over shall be liable in any manner for any personal injury Gr propcrty damage or a loss of any kind arising from or connected with this inspection.

Commissions

.a 23 d S I~ln~p ctori

'Na u ri il Ra rd. State. prov ilneo aind o

c. Spring
  • Arkwright-Boston Manufacturers Mutual Insurance Company - Mutual Boiler & Machinery Division.

I JLýýz i !

WO# 88662 R/R# 01-01-126 ASME Xl, CLASS 1 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section X1

1. Owner Carolina Power & Light Company P.O. Box 1551, Raleiah, N.C. 27602-1551 Address Plant Shearon Harris Nuclear Power Plant Name P.O. Box 165, New Hill, N.C. 27562-0165 Address
3. Work Performed By Carolina Power & Light Company Name Date 03/11/02 Sheet 1 of 2 Unit 1 WO# 88662 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp N/A Authorization No. N/A

4. Identification of System RC - Reactor Coolant 5

(a) Applicable Construction Code ASME Section III 1974 Edition, Winter '76 Addenda, See NI Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacement 1989

, Addenda N/A

6. Identification of Components Repaired or Replaced and Replacement Components
Repaired, ASME Code Name of Name of Manufacture National Other Year
Replaced, Stamped Component Manufacture Serial No.

Board No.

Identification Built Or Replacement (Yes or No)

Cartridge Seal Westinghouse Unknown N/A PN# 726-146-05 Unknown Replaced No Capscrews Cartridge Seal Westinghouse Unknown N/A W PN# 4936A901-120 Unknown Replacement No Capscrews PO# W 164608

7. Description of Work: Repalced three Cartridge Seal Socket Head Capscrews on "C" RCP.
8. Tests Conducted: Hyrostatic E] Pneumatic E] Nominal Operation Pressure E]

Other E] Pressure __

psi Test Temp. __

-F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2 in. X 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet in numbered and the number of sheet is recorded at the top of this form.

2.

WO# 88662 R/R# Q01-01-126 ASME Xl, CLASS 1 FORM NIS-2 (Back)

9. Remarks VT-1 performed on replacement cartridge seal capscrews.

Applicable Manufacturer's Data Reports to be attached.

N1 - See N-5 Data Report for Code Cases CERTICATION OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the repair or replacement ASME Code,Section XI.

Type Code System Stamp N/A Certific of Authoripation X N/A Expiration Date N/A

-e er-s Desgnee

,m Performnance Suoervisor Date 3/11/02 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of One State Street, Hartford, Connecticut 06102 have inspected the components described in this Owner's Report during the period of 05/13/00 to 12/14/01

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certification neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of and kind arising from or connected with this inspection.

SCommissions NC 1444 NIAB

  • pector's Signature National Board, State, Province, and Endorsements Date_______

(12/82)

WO# 88751 R/R# 01-01-127 ASME Xl, CLASS 1 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Carolina Power & Light Company P.O. Box 1551, Raleigh, N.C. 27602-1551 Address
2. Plant Shearon Harris Nuclear Power Plant Name P.O. Box 165, New Hill, N.C. 27562-0165 Address
3. Work Performed By Carolina Power & Light Company Name Date 03/11/02 Sheet 1 of 2 Unit 1 WO# 89751 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp N/A Authorization No. N/A

4. Identification of System RC - Reactor Coolant 5

(a) Applicable Construction Code ASME Section III 1974 Edition, Winter '76 Addenda, See Ni Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacement 1989

, Addenda N/A

6. Identification of Components Repaired or Replaced and Replacement Components
Repaired, ASME Code Name of Name of Manufacture National Other Year
Replaced, Stamped Component Manufacture Serial No.

Board No.

Identification Built Or Replacement (Yes or No)

  1. 1 Seal Housing Westinghouse 5828, 5823, 5785 N/A PN# 725-750-46 Unknown Replaced No Capscrews
  1. 1 Seal Housing Westinghouse 3996, 3975,3962 N/A W PN# 4934A79H16 Unknown Replacement No Capscrews PO# W195964
7. Description of Work: Repalced three #1 Seal Housing Capscrews on "B" RCP.
8. Tests Conducted: Hyrostatic E] Pneumatic [l Nominal Operation Pressure El Other El Pressure __

psi Test Temp.

-9F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2 in. X 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet in numbered and the number of sheet is recorded at the top of this form.

WO# 89751 R/R# 01-01-127 ASME Xl, CLASS 1 FORM NIS-2 (Back)

9. Remarks VT-1 performed on replacement #1 seal housing capscrews.

Applicable Manufacturer's Data Reports to be attached.

N1 - See N-5 Data Report for Code Cases CERTICATION OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the repair or replacement ASME Code, Section Xl.

Type Code System Stamp N/A Certifica, of Authorizati

o. N/A Signedn ed"/Y%-,

bwn'er Owner's dgigpýefitle Expiration Date N/A JV1 Equipment Performance Supervisor Date 3/11/02 A'rorac CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of One State Street, Hartford, Connecticut 06102 have inspected the components described in this Owner's Report during the period of 05/13/00 to 12/14/01

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certification neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of and kind a*

with this inspection.

Commissions NC 1444 NIAB Inspector's Signature National Board, State, Province, and Endorsements Date C

(12/82)

WO# 104667-03 R/R# 01-01-129 ASME Xl, CLASS 1 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Carolina Power & Liciht Company P.O. Box 1551. Raleiah. N.C. 27602-1551 Address
2. Plant Shearon Harris Nuclear Power Plant Name P.O. Box 165. New Hill. N.C. 27562-0165 Address
3. Work Performed By Carolina Power & Light Company Name Date 11/13/01 Sheet 1 of 2 Unit 1 WO# 104657-03 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp N/A Authorization No. N/A

4. Identification of System RC - Reactor Coolant 5

(a) Applicable Construction Code ASME Section III 1974 Edition, Winter 76 Addenda, See N1 Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacement 1989

, Addenda N/A

6. Identification of Components Repaired or Replaced and Replacement Components
Repaired, ASME Code Name of Name of Manufacture National Other Year
Replaced, Stamped Component Manufacture Serial No.

Board No.

Identification Built Or Replacement (Yes or No)

Coloc Nut Coloc Industries NA N/A Part# 514-108-01 Unknown Replacement No PO# 1047001

7. Description of Work: Replaced coloc nut on hanger RC-H-236.
8. Tests Conducted: Hyrostatic [l Pneumatic El Nominal Operation Pressure []

Other L] Pressure __psi Test Temp.

°-F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2 in. X 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (63) each sheet in numbered and the number of sheet is recorded at the top of this form.

WO# 104657-03 R/R# 01-01-129 ASME XI, CLASS 1 FORM NIS-2 (Back)

9. Remarks V--3 performed after coloc nut was replaced.

Applicable Manufacturer's Data Reports to be attached.

N1 - See N-5 Data Report for Code Cases CERTICATION OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the repair or replacement ASME Code, Section Xl.

Type Code System Stamp N/A Certificat of Authoriz n No.

Signed nm I* -,

ýXf'I Owner*I Owner D-esir6el N/A Expiration Date N/A Eaipment Performance Supervisor Datet 11/13/0

~,Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of One State Street. Hartford, Connecticut 06102 have inspected the components described in this Owner's Report during the period of 05/13/00 to 12/14/01

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certification neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of and kind arising from or connected with this inspection.

Commissions Inspectors Signature Date_________________

NC 1444 NIAB National Board, State, Province, and Endorsements (1 2J82)

K SGRP WR/JO NUMBER TAG ESR NUMBER ASME CODE CLASS REPAIR OR REPLACEMENT 88568 RCS PIPE 97-00810 1

REPLACEMENT 88568 TIE RODS 97-00810 1

REPLACEMENT 88568 SG 97-00810 1

REPLACEMENT 90104 AFW SUP 97-00807 2

REPLACEMENT 90104 AFW PIPE 97-00807 2

REPLACEMENT 90104 MS PIPE 97-00807 2

REPLACEMENT 90208 BD PIPE 97-00808 2

REPLACEMENT 90208 BD PIPE 97-00808 2

REPLACEMENT 90208 BD PIPE 97-00808 2

REPLACEMENT 90208 BD PIPE 97-00808 2

REPLACEMENT 90208 BD PIPE 97-00808 2

REPLACEMENT 90208 BD PIPE 97-00808 2

REPLACEMENT 90208 BD PIPE 97-00808 2

REPLACEMENT 90208 BD PIPE 97-00808 2

REPLACEMENT 90208 BD PIPE 97-00808 2

REPLACEMENT 90208 BD PIPE 97-00808 2

REPLACEMENT 90208 BD PIPE 97-00808 2

REPLACEMENT 90208 BD PIPE 97-00808 2

REPLACEMENT 90208 BD SUP 97-00808 2

REPLACEMENT 90208 BD SUP 97-00808 2

REPLACEMENT 88568 SG ULS 97-00810 2

REPLACEMENT 90104 FW PIPE 97-00807 2

REPLACEMENT 90104 FW SUP 97-00807 2

REPLACEMENT 88568 SG LLS 97-00810 2

REPLACEMENT Page 1

/

R/R# 01-01-200 ASME Xl, CLASS 1 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions for the ASME Code Section Xl

1.

Owner:

Carolina Power & Light Name P.O. Box 1551, Raleigh, N.C. 27602-1551 Address

2.

Plant:

Shearon Harris Nuclear Power Plant Name P.O. Box 165. New Hill-NC. 27562-0165 Address

3.

Work Performed by:

Becon Construction Name P.O. Box 9, New Hill, N.C. 27562 Address

4.

Identification of System:

RCS CROSSOVER LEG SUPPORT Date:

12/24/01 Sheet 1

of 4

Unit 1 23R3R Repair Organization P.O. No., Job No., etc Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A

5.

(a) Applicable Construction Code: ASME Sec Ill Edition 1974 Addend (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements: 1989

6.

Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Component Manufacturer Serial No.

Board Identification:

No.

See attached a Winter 76 Code case N/A Addenda N/A Year Repaired ASME Built Replaced Code Or Stamped Replacement Yes/No

7.

Description of Work: The existing RCS Crossover Leg Supports were modified during Steam Generator replacement by cutting out the existing welded shims. Following shim removal from the support structures, the supports were drilled and tapped to receive angle steel at each horizontal and vertical location. The angles provided a base for the two bolted shims which were installed across the supports at each horizontal and vertical location. One shim in each stack was tapered to provide a flat surface and additional shims of various sizes were then installed to provide the desired gap at cold conditions. Hot Gap Testing was performed at approximately 195°F, 3451F, 450°F and 5571F to ensure that the desired gaps were achieved at normal operating temperatures.

8.

Tests Conducted:

Hydrostatic El Pneumatic []

Nominal Operating Pressure E]

Other 0l Pressure__ psi Test Temp.

-F NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 % in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12/82)

Form NIS-2

9.

Remarks Reference lipe 6 for code d-at-r-port Applicable Manufacturer's Data Reports to be attached VT-3 was performed after the RCS crossover leg restraints were modified.

R/R# 01-01-200 ASME XI, CLASS 1 Sheet 2 of 4

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this rep.lcement conforms to the rules of the repair or replacement ASME Code,Section XI.

Type Code Symbol Stamp MIA Certificate of Authorizaion No.

INA Expiration Date N/A Signed

,.-Equipment Performance Supervisor Date

/

f

, 20 0 2,

,'Pneri-W Ot r's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carnlina and employed by Hartford Steam Boiler Inspection and Insurance Comoanv of One State Street.

Hartford-Connecticut 06102 have inspected the components described in this Owner's Report during the period 05-13-00 to 12-14-01

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

C n

_____________________________Commissions NC 1444NIAB Inspector's Signature National Board, State, Province, and Endorsements Date z- "

?

20 1

I

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet Sheet 3

of 4

Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board No.

Identification:

Built Replaced Code Or Stamped Replacement Yes/No Angle 6" x 4" Nucor steel N/A N/A HT# 606651 Unk Replacement No ASTM A36 5/8"-11 UNC-2A X Unytite, inc.

N/A N/A HT# L02260 Unk Replacement No 1 1/2" LG. Heavy Hex Structural Bolt ASTM A326 5/8-11UNC-2A X 3 T & T N/A N/A HT# 8990617 Unk Replacement NO Heavy Hex Enterprises Structural Bolt With ASTM 325 2 1/2" Thread Length TYPE 1 5/8-11 UNC-2B, Unytite, Inc.

N/A N/A LOT#

Unk Replacement No Heavy Hex Nut 0040036825 HT# S28833 ASTM A-563 GR DH 5/8" Standard Prestige N/A N/A HT# 187534 Unk Replacement No Flat Circular

Stamping, Washer Inc.

ASTM F436 Plate 1 1/4" CitiSteel N/A N/A HT# 10469 Unk Replacement No USA Incorp.

ASTM A36 Plate 1" Kenilworth N/A N/A HT# Y08953 Unk Replacement No Steel Co.

ASTM A36 5/8"-1 1 UNC 2B Nova N/A N/A HT# B87035 Unk Replacement No Heavy Hex Nut Machine Products ASTM-194 Corporation Gr. 2H 5/8" x 3 1/2" Provided by N/A N/A Lot 73652752 Unk Replacement No Structural Bolt CP&L ASTM A-325 Plate 3/4" Kenilworth N/A N/A HT # D02407 Unk Replacement No Steel Co.

ASTM-A36 Plate 1/2 x 6 Roanoke N/A N/A HT# JC3653 Unk Replacement No Electric ASTM A-36 Steel Corp..

Plate 1/4" Bethlehem N/A N/A HT# T0286 Unk Replacement No Steel ASTM-A36

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet Sheet 4

of 4

Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board No.

Identification:

Built Replaced Code Or Stamped Replacement Yes/No Plate 1/16" Precision N/A N/A HT# T4364 Unk Replacement No Steel Warehouse, ASTM-A109 Inc.

Plate 3/8" Bethlehem N/A N/A HT# T2128 Unk Replacement No Steel ASTM A572 GR50TYPE2 5/8" Harden Flat Nova N/A N/A LOT #

Unk Replacement No Washer Machine Products 0040036362 Corp.

HT # 210857 ASTM F-436 PLATE 1/32" Bethlehem N/A N/A HT # 411 K3141 Unk Replacement No Steel Corp.

ASTM A366-97 5/8" x 3 1/2" Provided by N/A N/A Ht # 11557 Unk Replacement No Structural Bolt CP&L ASTM SA1 93

R/R# 01-01-202 ASME X1, CLASS 1 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions for the ASME Code Section XI

1.

Owner:

Carolina Power & Light Name P.O. Box 1551, Raleigh, N.C. 27602-1551 Address

2.

Plant:

Shearon Harris Nuclear Power Plant Name P 0 Rny 165. New Hill N (

27flM2-O16 Address

3.

Work Performed by:

Becon Construction Name P.O. Box 9. New Hill. N.C. 27562 Address

4.

Identification of System:

RCP Tie Rod, Loops "A", "B", 'C" Date:

12/24/01 Sheet 1 of

- 2 Unit 1 Repair Organization P.O. No., Job No., etc Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A

5.

(a) Applicable Construction Code: ASME Sec. III Edition 1974 Addenda Winter 1976 Code Case N/A (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements: 1989 Addenda N/A

6.

Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board Identification:

Built Replaced Code No.

Or Stamped Replacement Yes/No 8" 0 Sch. 80 PROVIDED BY P/N N/A HT# C04644 UNK Replacement No Pipe CP&L

51414555, REQ 334
7.

Description of Work: The TRB-1 and TRB-2 RCP Tie Rod Ends were modified during the Steam Generator Replacement. The TRB-1 tie rods were modified by machining the pins which connect the tie rods to the end brackets. This established the desired cold gap measurement at the loops "A" and "C". Loop "B" required installation of a crescent shaped shim to achieve the desired gap at the top of the pin in addition to the machining of the pin. The TRB-2 Tie Rods Ends on each loop received crescent shaped shims at the top and bottom of the bracket at each loop. VT and MT inspections were oerformed on each modified comrcno.ntn TRB-3 Tie Rod Ends received no modifications, however, Hot Gap Testing was performed at approximately 195°F, 345°F, 450*F and 557°F to ensure that the desired gaps were achieved at normal operating temperatures.

8.

Tests Conducted:

Hydrostatic El Other []

Pneumatic 0l Pressure __

psi Nominal Operating Pressure [I Test Temp.

oF NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 Y2 in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12/82)

R/R# 01-01-202 ASME Xl, CLASS 1 Form NIS-2 Sheet 2 of 2

9.

Remarks Reference line 6 for code data reports.

Applicable Manufacturers Data Reports to be attached VT-3 performed after RCP Tie Rod modification.

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replnrcgment conforms to the rules of the repair or replacement ASME Code,Section XI.

Type Code Symbol Stamp NIA Certificate of Authorizatio 0o.

NIA Expiration Date N/A Signe

)

ner-ner'esig.ee T*it Equipment Performance Supervisor Date

/

-,20 0

" 4*

n*wre r br'-Owne e esig *ee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carnlina and employed by Hartford Steam Boiler Inspection and Insurance Company of One State Street.

Hartford-Connecticut 06102 have inspected the components described in this Owners Report during the period 05-13-00 to 12-14-01

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NC 1444NIAB

-- Inspector's Signature National Board, State, Province, and Endorsements Date 20

REPAIR/REPLACEMENT SYNOPSIS DATE 02/13/02, REV. 0 Repair [

Replacement R Suitability Evaluation Required ELYes [INo

1. SYSTEM NAME RC - Reactor Coolant CONSTRUCTION CODE ASME Section III CODE CASE See N-5 Data Report
2. COMPONENT NAME Steam Generator OLD COMPONENT P.O. No./Catalog ID.

Year Built 1976 Code Stamp Yes Const. Code ASME III Edition 1971 Addenda S72 Code Class 1 Code Cases See #3 NB No. "A" - W11304, "B" - 11309, "C" - 11307 Manufacture Name Westinghouse Manufacture Serial No. 1631. 1632. and 1633 R/R No. 01-01-203 ESR No. 97-00810 W/O No. 88568 NB No. 55 Edition 1974 Addenda W76 Code Class 1 Tag No. 1SG-E001, E002, E003 NEW COMPONENT P.O. No/Catalog ID.

Year Built 1998 Code Stamp Yes Const. Code ASME III Edition 1986 Addenda N/A Code Class 1 Code Cases See #3 NB No. "A" - 63, "B" - 64, "C" - 65 Manufacture Name Westinghouse Manufacture Serial No. 12243, 12244, and 12245

3. DESCRIPTION OF WORK Replaced A. B and C steam generators. The new generators were recociled Der ESR 97 00810. Threfore. suitable for replacement. Code Cases used for replaced generators are NB4642, NB4643, 1484, 1493-1. and 1355. Code Cases used for replacement generators are N-20-3. N474-1, N2142, and N-2143.
4. PRESERVICE INSPECTION REQUIREMENT MT - Mag. Part.

Complete [

El PT - Penetrant Complete El EL RT - Radiography Complete EL

[

UT - Ultrasonics Complete 0

[

VT-2 Visual Complete El

6. SYSTEM PRESSURE TEST REQUIREMENT 0

Leakage El Functional El Inservice El Hydrostatic nl Pneumatic

5. PROGRAM UPDATES REQUIRED IS1I Supports [

IST E]

ILRT/LLRT [I FAC [U Other Check Valve El Nominal Operating Pressure Z Yes El No Elevated Pressure N/A psi Test Temperature N/A OF Applic. Code Ref. (or Code Case) N/A

7. ANI/ANII Review

_/__//__

Pre Work Status 06/28/01

8. NIS-2 Prepared 02/13/02 ANI/ANII 11111 0"I2-Work Complete 11/16/01 In Package 312 4o0-1 Note: Upon completion of the document, it is a completed QA record and is to be transmitted in accordance with RDC-NGGC-0001.

Page 17 of 30 Sheet 1 of 1 PLP-605 Rev. 22

WO# 88568 R/R# 01-01-203 ASME Xl, CLASS 1 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner Carolina Power & Light Company 2.

P.O. Box 1551, Raleigh, N.C. 27602-1551 Address Plant Shearon Harris Nuclear Power Plant Name P.O. Box 165, New Hill, N.C. 27562-0165 Address

3. Work Performed By Carolina Power & Light Company Name Date 02/13/02 Sheet 1 of 2 Unit 1 WO# 88568 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp N/A Authorization No. N/A

4. Identification of System RC - Reactor Coolant 5 (a) Applicable Construction Code ASME Section III 1974 Edition, Winter'76 Addenda, See N1 Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacement 1989

, Addenda N/A

6. Identification of Components Repaired or Replaced and Replacement Components
Repaired, ASME Code Name of Name of Manufacture National Other Year
Replaced, Stamped Component Manufacture Serial No.

Board No.

Identification Built Or Replacement (Yes or No)

Steam Generator Westinghouse 1631 W11304 SG-A 1976 Replaced Yes Steam Generator Westinghouse 1632 W11309 SG-B 1976 Replaced Yes Steam Generator Westinghouse 1633 W11307 SG-C 1976 Replaced Yes Steam Generator Westinghouse 12243 63 SG-A 1998 Replacement Yes Steam Generator Westinghouse 12244 64 SG-B 1998 Replacement Yes Steam Generator Westinghouse 12245 65 SG-C 1998 Replacement Yes

7. Description of Work: Replaced A, B and C Steam Generators.
8. Tests Conducted: Hyrostatic E] Pneumatic F] Nominal Operation Pressure [

Other El Pressure ____psi Test Temp.

°F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2 in. X 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet in numbered and the number of sheet is recorded at the top of this form.

WO# 88568 R/R#.01-01 -203 ASME Xl, CLASS 1 FORM NIS-2 (Back)

9. Remarks Performed ASME XI preservice examination on new steam generators including VT-2.

Applicable Manufacturer's Data Reports to be attached.

N1 - See N-5 Data Report for Code Cases CERTICATION OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the repair or replacement ASME Code, Section Xl.

Type Code System Stamp N/A Certificate of Authorizatticn No. N/A Expiration Date N/A Signed,)

F

'A

,f--

,-Eauipment Performance Supervisor Date 2/13/02 16"wn el r"Own e l'U-'es`t e, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Comoany of One State Street, Hartford, Connecticut 06102 have inspected the components described in this Owners Report during the period of 05/13/00 to 12/14/01

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certification neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of and kind arising r orconnected with this inspection.

Commissions NC 1444 NIAB Inspector's Signature National Board, State, Province, and Endorsements Date z

'*"Z-e Z--

(12/82)

SFORM N-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR VESSELS As Required by the Provisions of the ASME Code.Section III. Division 1 Ps. 1 of 4

Westinghouse Electric Company, Pensacola Plant No. 5

1. Manutacluredand.cerafied by 8301 Scenic Highway, Route 90, Pensacola, Florida 32514-7810 ditrra &-a bac,.ss of '11 coencale '..oaerl
2. Manufacwuredfor Carolina Power and Light Company, Shearon Harris Unit-i, Raleigh, Nor-h Oa" "Gross""f Pturnse'l" Carolina 29-06
3. Locationofinstallation Shearon Harris Nuclear Power Plant, P.O. Box 165 State Road 1134 Steam If" *"e "
Newhill, NC 27562-01625*
4. Tyoe:

Vertical Generator SG3L-122t3 6119gE35 Rev.2 63 8198 the... a..04?.)

Ii~ta4* Iat¢etea. netl.al.

(Can. MO'Waefs so.

no I

CANI tarw~n'g nob.1 uhltia ta.

Ia

o.
5. ASME Code. Section Ill. Division 1:

1986 None 1

N-20-3, N-2142 4 00. 110o 1

la ao S n a i sa,ela 4 0 s 22 lC a e C as e n o.j Items 5-10 inclusive to be completed lot single wall vessels, jackets of jacketed vessels, or shells of hear exchaagers.

6. Shell:
  • 1 "1

"1 "1

"1 67' 7/8" Total imati'. s0*o. neo.

itenslr strongin, I4cm. ntnc.ness Ir4.11 lman. cosen macanes in.1l Ialo. I0 Ill & n.JI gm 4

nooraaa lit &

4&

7. Seams:

doub*eiutt Full Full 5

["e s.I iNT's ItA) toll. %l f1gmrf fl' IRT) fn** C l

8. Heads:SA-508 Cl3a 90 ksi N/A N/A l 1141SmI. 11o1C.000.1 1ten9le 2t thOlin.

l1l5 Ma2l. sieee. no.1 ionsaie stwengins Loctio crown,.n JKnuckle GWW"a J cortical

)S"Misoneu'tcal Flat S-00 Io Pressure I

food. bottom. wt Thr s

Radius Radius

Ratio,

&Amu Ate Radius 0.ownto,.

aCon Or cn-a*-"

l(a I TOP I 3.85 1 N/Al NIA 1 2:1 1 N/A I

N/A I

N/A I Concave I

Lb I I

I I

I I

I I

If removable, bolts used N / A Other fastening N IA Imat'I. sec. no.. 2026. Gluanblyl Wescb.O a.t tocn skilc"l

9. Jacketclosure: Girth Weld -

DBL Butt, Full P.W.H.T.; Full R.T.

iex sen o

a.

& wow. bar. eia. II bar.

Owe di.me.-.on.. oesastre or sketCOr

10. Design pressure21,85 at max. temp. 600

. Min. pressure-test temp.

70

  • Pneu. h or comb. test pressure1 182 PSI Items I I and 12 to be completed for tube sections.
11. Tubesheets:

SA-508 Cl 3a 129.38" 22.70" Welded Illsanonary. m*sl, so"t. no.3 Id.an.m. Isubsoct to aress..s Itfuckesks tin.)l la::ac1,mant Iweloed. ballea llielaing. metN'I. go". no.)

Idia. Ion.))

ltniknoss lwnI tallllac*l mentl

12. Tuoes:SB-163UNS06690 11/16"

.040" Nom.

6307 U

Amotvi. soot. no.

100 in.11 Iltli*mkneS 4i*n.. OF "964ll 1n1.1 hvas listraigttt or Ull Items J 3 to 16 inclusive ro be completed for inner chambers of jackered vessels. or channels of hear exchangers.

13. Shell:

IimSat. 3o0t. n0.1 tio34le amregltn Inom.

  • h*cknoss 4in.1l Iman. aosign struckoess lin.ll Icsa. to lit. & in.

ll longin eii rUlll lit & -lnL)

14. Seams:

Girth Full Full Ilang. Iwesloc. d*o.. sngljll INT' Iles or noil lAT) left. %I Ii.nn1 IHNT'I IRTA

[.o. at ¢o.,sefl

15. Heads:

SA-508 Cl3a 90 ksi lial 2tD..

r".eI o

$"e Sreongithf Ross not'. $oot. 0o.1 llsl.o steonotg l lIc) mall. 2s11. A0.1 11434-S rOengtlh Crown Knuekle Eletm¢al Conical asneionontfh n'm Sac ao POr=:oSS CaLocoen Thcanoss Radius Radi o A*.

j it ICS lI I

i I

I e

I I

1IblChannel 1 5.26" I

I I

1 62.81" I

I Concave I Id Foatng I

I I

I I

I I

I It removable, bolts used

__Other fastening Ices'l. s24C, no.. 3-20. Quanbt'orl ao.oe00 a, etttlieh sikttN

16. Design pressure 2 4 8 5 PSI 6at 50 Min. pressure-test temp.

70 Pneu.

r comb. test pressure

-PSIG

""Il

  • stwaid m1`l 1r1atea.

I of?.

ot.her 0"lot*#

oeef porssure -o m o3mn*cncwao ne beroetor me won 6 8*aDa¢*t

  • Si00olemental,nfoemation mn form of lists. saietches. or Drawings may bo used Providead Ill size is 8W X 11. 121 information in items I ftrough 4 on triiS

?;i ta

.! fcliu¢ee on 0e4c.- sneet. (31 each sneet,s numoered and numOer of Sheets as recorded at too of this form.

32.

a

"'-%s !orm !E0O (381 may oe detainee from ine Order Deat.. ASME. 22 Law Drive. Box 2300. Fa,rfiei..NJ Z7Y C -23CO

FORM N-1 (Back -

Pg. 2 of

, )

Certificate Holcer's Serial No. SG3 L-722 t Nozzles. inspection and safety valve openings:

outlet, ouan. a te.)

i Qantv Oia. or Siet Tyoe Attacned jA. Th.ckats s hnateea.

Lac~

S

  • 1 I

1*1 "1 *1 I *1 1 1

  • 1 I"

i i

i I

18.

19.

I I

I I

I I

I I

I I

!I I

I I

I I

I I

I I

I I

II I

Supoorts: Skirt Lugs Legs Other Attached Integral with tube olate (yes a 't n ap (oIuanti yI I

_a4 1tly p Il eoscn Oel lw ns.. uio w Remarks:

None sion 1

CF.R I ;CTN

).O.IGN Design specification certified by G. V. Smith P.E. State FL Reg. no. 0045390 Design report certified by C.

A.

Lockhart P.E. State FL Reg. no. 0044043 CERTIFICATE OF SHOP COMPLIANCE We certify that the statements made in this report are correct and that this nuclear vessel conforms to the rules for construction of the ASME Code. Section Ill. Division 1.

N Certificate of Authorization No. N-1669 Expires I 4March 11-2001 Date q________"

Name Westinghouse Electric Co.

Signed R (60e, IN C.IIII4I.

141e.,lR.

HUAndT'11AUV 'oarse@ftit-a).

CERTIFICATE OF SHOP INSPECTION I. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Florida and employed by Arkwright Mutual Ins; Co.

of

Waltham, MA have inspected the component described in this Data Report on

'/* ý

. and state that to the best of my knowledge and belief, the Certificate Holder has constructed this component in ac cordance with the ASME Code. Section I1I. Division 1.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the component described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from r o with this inspection.

DateW*YL're Signed

-fti'frA1&'

Commissions NB7245 N FL 328 W. Y or~es 4Authud Insipector

[Nst'l. ad. (inc. andorsmental and state or peow. and no.]

N/A CERTIFICATE OF FIELD ASSEMBLY COMPLIANCE We certify that the statements on this report are correct and that the field assembly construction of all parts of this nuclear vessel conforms to the rules of construction of the ASME Code. Section II1. Division 1.

N Certificate of Authorization No.

Expires Date Name Signed IN Cortiieue MidonI8u~tOtkoiZe

?roesentatsl"4 N/A CERTIFICATE OF FIELD ASSEMBLY INSPECTION I. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of and employed by of have compared the statements in this Data Reportwith the described component and state that parts referred to as data items

. not included in the certifkcate of shop insoection. have been inspected by me on and that to the best of my knowledge and belief the Certificate Holder has ponstructed and assembled this component in accordance with the ASME Code. Section Ill, Division 1.

i By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the component described in this Data Report. Furthermore. neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or I a loss of any kind arising from or connected with this inspection.

I Date Signed Commissions(

[AAuh...z~d Il*D.eC~tOe (Nat]l. k(. lind:..'tdcot$frs qln,ntsi andO sawi or prov. and] no.j r

7.

FORM N-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR VESSELS' As Required by the Provisions of the ASME Code. Section Ill. Division 1 Pg. 3 of Westinghouse Electric Company, Pensacola Plant No. 5

1. Manufacturedandcertifiedby 8301 Scenic Highway, Route 90, Pensacola, Florida 32514-7810 iname and addless of N
  • 4 neilcjte moodr)
2. Manufacmuredfor Carolina Power and Light Company. Shearonl Harris Unit-i Raleigh, North inrtand address of Purcmaear, aoin 96 S'

... '= '="" ° P='"'"Ca rolina 2-9 0 6 5ý

3. Location of installation Shearon Harris Nuclear Power Plant. P.O. Box 165 State Rond 1134 Steam (name and "cress)
Newhill, NC 27562-01625
4. Type.

Vertical Generator SG3L-12243 6149E35 Rev.2 63 1998 IMona:. of verl.

1flank. lCketed. host ex.]

iCon. HOwder's snal no.i ICANI (ra.wmg no.-

mNatol. So. no.i r

N-20-3, N-2142

5. ASME Code. Section 1II.

Division 1:

1986 None 1

N-47T-i, N-421t.3 IedlitonJ adden9da data)

(las$1 ICO4: case no.)

  • 1 Component A' Barrel 8' Barrel

'H' Barrel J Barrel Stub Barrel Transition Cone Drawing #

6148E99 6148E99 6148E99 6148E99 6148E99 6144E63 IT.

H02 H03 H04 H05 H01 H03 Rev.

03 03 03 03 03 03 Madl Spec. #

SA-533 Type B CL.2 SA-533 Type B CL2 SA-533 Type B CL2 SA-533 Type B CL2 SA-533 Type 8 CL2 SA-508 CL3a Tensile Strength (Min.)

90 ksi 90 ksi 90 ksi 90 ksi 90 ksi 90 ksi Thickness Nom.

Min.

3.74' 3.24" 3.74' 3.24' 4.38' 3.88' 4.38' 3.88" 5.20' 4.70' 3.35" 3.31' Dia.

Overall Length 111' 1/3" 10, 1/3" 11' 1/3" 10' 103 14'/4" 9' 7116" 14 Y4" 9'$3/8' 11 '

T 7' 13/16" 14' 11/16" 7 5/8'

  • 1 Nozzles. Inspection and Safety Valve Openings Purpose Feedwater Nozzle Primary Nozzle Steam Outlet Auxiliary Feedwater Secondary Blowdown Secondary Shell Drain Sampling Tap Water Level Tap Primary Manway Secondary Manway Inspection Port Inspection Port Handhole Sludge Collector Weld Overlay:

QTY.

1 2

1 2

1 1

8 2

2 2

16 6

2 Dia. (In) 16' 31*

32' 7"

2" NPS 1" NPS 2T NPS Y/4NPS 16' 16' 4!

2' 6"

2' Type Weld End Forged Weld End Weld End Weld End Weld End Weld End Weld End How Attached Welded Integral Welded Welded Welded Welded Welded Welded Marl Sf4 a hrl"Q SA-508 CL3a SA-508 CL3a SA-508 CL.3a SA-508 CL3a SA-508 CL3a SA-508 CL3a SA-508 CL3a SA-508 CL3a SA-508 CL3a SA-508 CL.3a 0.79" 5.17" 1.31' 0.75" 0.79' 0.45" 0.54" 0.46" 5.94" 5.62" Reinforcement Mat'l SA-508 CL3 SA-508 CL3 SA-508 CL.3 SA-508 CL.3 Location Secondary Primary Secondary Secondary Secondary Secondary Secondary Secondary Primary Secondary Secondary Secondary Secondary Secondary Primary side surface of the tube plate is overlaid with weld-deposited nickel-chromium-iron alloy. The Channel Head interior surfaces, including nozzles and manways, is overlaid with stainless steel weld deposit Primary Nozzles include safe-ends of SA-336, CL.F 316LN material.

MnYI Rr*

FORM N-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR VESSELS As Required by the Provisions of the ASME Code. Section iII. Division 1 Pg. 4 of Westinghouse Electric Company, Pensacola Plant No. 5

1. Manufactured and certified by 8301 Scenic High.ay, Route 90, Pensacola, Florida 32514-7810 Inam. and addresS at N Cdrwficate Maolawi
2. Manufactured for Carolina Power and Light Company. Shearon Harri Unft-,

Raleigh, Noorth

'ama nd address Pa Carolina 2906-5sa

3. Location of installation Shearon Harris Nuclear Power Plant. P.O. Box 165 State Ronad 113 Steam

,name and,=o,,2

Newhill, NC 27562-01625
4. Type:

Vertical Generator SG3L-12243 6149E35 Rev.2 63 1998 IhOan. or art.l (tank. jacketed. heat ex.j lCan. Holder's 3enal nao.J ICRN) ldva.w g no.j Nil. o. "oi Lyear Ow

5. ASME Code, Section 111, Division 1:

1986 None 1

N-20-3 N-2142

5.

ASE Coe.

Sctio III Divsion1:-186 Nne,1N-2143 Idito!

(addenda datD (cl~ass)

ICode Case nO.

Notes:

1)

Unit received a full post weld heat treatment.

2)

Unit received a full R.T. examination.

3)

Post-hydro M.TJP.T. examination of Steam Generator performed.

4)

Nozzle shipping caps are not part of this manufacturer's data report.

FORM N-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR VESSELS' As Required by the Provisions of the ASME Code.Section III, Division 1 Pg. 1 of 4

Westinghouse Electric Company, Pensacola Plant No. 5

1. Manufacturedandcertifiedby 8301 Scenic Highway, Route 90, Pensacola, Florida 32514-7810 fname and address of N Certificate Holder)
2. Manufactured for Carolina Power and Light Company, Shearon Harris Unit-i, Raleigh, North

,name and address of Purchaser)

Carolina 29065

3. Location of installation Shearon Harris Nuclear Power Plant, P.O. Box 165 State Road 1134 Steam (nameandaddress)
Newhill, NC 27562-01625
4. Type:

Vertical Generator SG3L-12244 6149E35 Rev.2 64 1998 Ihoriz. or vent.)

(tank. jacketed. heat ex.I ICelt. Holder's serial no.)

[CRNI Ifdrawng no.)

Nar'l. ad. no.)

[year bail)I N-20-3, N-2142

5. ASME Code.Section III, Division 1:

1986 None 1

N-274-13 N-2143 (edition)

(addenda date)

[class)

(Code Case no.)

items 6-10 inclusive to be completed for single wall vessels, jackets of jacketed vessels, or shells 07 heat exchangers.

6. Shell:

1 "I

"I

  • 1 67' 7/8" Total Imat'l. soec. no.)

(tensile strength)

(nom. thickness (inIl Imin. design thickness lin.)I Idia. 10 fIt & in.)

Ilength [overall) It & in.11

7. Seams:

ou JB t Full Full5 (long.I (HTVI (RT) left. %)

Igirthl

)HT')

IRT)

Ino. of courses)

8. Heads:SA-5 0 8 Cl3a 90 ksi N/A N/A Ila) mat'l, soec. no.

(tensile strength) l(bi mat'l, spec. no.)

(tenslle strength)

Location fCrown Knuckle Elliptical Conical Hemispherical Flattr Side to Pressure ttop. bottom, ends]

Thickness Radius Radius Ratio Apex Angle Radius Diameter (convex or concavel (a) 1 TOP I 3.85 I N/A N/A I 2:1 N/A N/A I N/A I Concave (b )

I I If removable, bolts used NIA Other fastening N/A imat'l. spec. no.. size. quantity)

(describe or attach sketch)

9. Jacketclosure: Girth Weld -

DBL Butt, Full P.W.H.T.; Full R.T.

(Describe as ogee & weld. bar. etc. If bar. give dimensions. describe or sketch)

10. Design pressure 21185 atmax.temp.

600o Min. pressure-test temp.

70

  • Pneu.

d or comb. test pressure 1 482 PS IG Items 11 and 12 to be completed for tube sections.

11.

Tubesheets:

SA-508 Cl 3a 129.38" 22.70" Welded (stationary. matrl, spec. no.)

Idia. in. (subject to press.!)

(thickness [in.!l (attachment (welded. bolted))

(floating. mar'l, Spec. no.)

Idia. (in.)l)

Ithickness (in.)I (attachment)

12. Tubes:SB-163UNS06690 11/16"

.0400" Nom.

6307 U

Imat'l. spec. no.!

IO0 (in.!)

lthickness (inches or gagell (no.)

Itype (straight or ul)

Items 13 to 16 inclusive to be completed for inner chambers of jacketed vessels, or channels of heat exchangers.

13. Shell:

(mat'l. Spec. no.!

(tensile strength!

Inom. thickness (in.))

(win. design thickness (in.)l (dia. ID (ft. & in.11 (length loverall Ift & in.)l

14. Seams:

Girth Full Full (long. (weloed. dbl.. single!l (HTV (yes or noJl (RTI (elf. %)

(g~rth)

(HT 1 '

IRT)

(no. of courses)

15. Heads:

SA-508 Cl3a 90 ksi ila) nat'l. soec. no.1 Itensile strengthl I(bl mat'l. soec. no.!

(tensile strengthl tic] mat'l, soec. no.]

(tensile strengthl Crown Knuckle Elliptical Conical Hewsoherlcal Flat Side to Pressure Location Thickness Radius Radius Ratio Apex Angle Radius diameter (convex or concavel (a) Top, bottom, ends I

I-!

(b) Channel 15.26" I....

I ---

I 62.81" Concave (c) Floating i

i I

If removable, bolts used Other fastening Imat',. spec. no., size. quantityl (describe or attach sketcnh

16. Designpressure, at _2485PSIG Min. pressure-test temp.

70

.Pneu., h r comb. test pressure 3107 PSIC

/Dsi)

(iF

[F)*

E c`lsID It oostwela "eat treated.

'List other internal or external pressure with coincident temperature when aoolicaole.

"Suoplemental information in form of lists. sketches, or drawings may be used provided (It size is 81/a x 11. (2) information in items 1 through 4 on this Data Reciort is included on each sheet. i3) each sheet is numbered and number of sreets is recorded at too of this form.

i1 Z88)

This form (EO0038) may be obtained from the Order Deot.. ASME. 22 Law Drive. Box 2300. Fairfield. NJ 07007-2300.

FORM N-1 (Back -

Pg. 2 of 4

)

Certificate Holder's Serial No. SG3L-- 2244

17. Nozzles, inspection and safety valve openings:

Puroose ranlet. -

IrTt outlet. drain. evc.)

L uan~ttv J Oa. or Size A

ye t~taoched "I

1 1

"I*1 I

  • 1 i

Reinforcement Mat'.

Thickness Material Location I

i

.1.

I I

I I

a

.1.

I I

I I

j I

I I

18. Supports: Skirt Lugs.-

Legs Other Attached integral with ti~hp nfp (yes or noi iduantltyi (Quantrtyl O

(descrbe)

Atwaere woihi

19. Remarks:

None CE*TJF)CA *N SIGN Design specification certified by G.

V.

Smith CE. F P.E. State FL Reg. no. 0045390 Design report certified by C.

A.

Lockhart P.E. State FL Reg. no. 0044043 CERTIFICATE OF SHOP COMPUANCE We certify that the statements made in this report are correct and that this nuclear vessel conforms to the rules for construction of the ASME Code,Section III, Division 1.

N Certificate of Authorization No.

N-1669 Expires M1rch 11 2001 Date Name Westinqhouse Electric Compan'ligned 1

IN Certificate Holder)

R.

H'.(JAnr`ri`

ze-rePr-ent CERTIFICATE OF SHOP INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Florida and employed by Arkwriaht Mutual Ins. Co.

of Waltham.

MA have inspected the component described in this Data Report on

/*

. and state that to the best of my knowledge and belief, the Certificate Holder has constructed this component in ac cordance with the ASME Code,Section III, Division 1.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the component described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or prope.'ty damage or a loss of any kind arising from 0o with this inspection.

Date4* q4 Signed

/weJ/t*

Commissions NB7245 N FL 328 W-. y././5 5sAuthoried,.,°cttor)

IN,'l. 8d. )inci. endorsements) and state or p.o.. and no.,

N/A CERTIFICATE OF FIELD ASSEMBLY COMPLIANCE We certify that the statements on this report are correct and that the field assembly construction of all parts of this nuclear vessel conforms to the rules of construction of the ASME Code,Section III, Division 1.

N Certificate of Authorization No.

Expires Date Name Signed (N Certificate Holderi lauthornzed representatime)

N/A CERTIFICATE OF FIELD ASSEMBLY INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of and employed by of have compared the statements in this Data Report with the described component and state that parts referred to as data items not included in the certificate of shop inspection, have been inspected by me on and that to the best of my knowledge and belief the Certificate Holder has co~istructed and assembled this component in accordance with the ASME Code.Section III, Division 1.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the component described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Date Signed Commissions I

I i

I II 19.I Re ai:N n

(Author, Zed InsoeclOt]

[Nat'l. ad. iincl. endorsements) and state or Drov, andi no. ý

FORM N-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR VESSELS*

As Required by the Provisions of the ASME Code, Section Ill. Division 1 P

Westinghouse Electric Company, Pensacola Plant No.

5

1. Manufactured and certified by 8301 Scenic Highway, Route 90, Pensacola, Florida 32514 (name and address of N Cetltfcat, HmOieri
g. 3 o 4

-7810

2. Manufac~uredfor Carolina Power and Light Company. Shearon Harris Unit-I Raleigh., North 2name and address of Pureha..e.

Carolina 29065

3. Location of installation Shearon Harris Nuclear Power Plant. P.O.

Box 165 State Road 1134 Steam name and"address Newhill, NC 27562-01625

4. Type:

Vertical Generator SG3L-12244 6149E35 Rev.2 64 1998 lho4z. or aert.l Itank. jaCkeled. heal x.)

(Car%. HlOIdr's serial no.)

(CRNI Idrawing no.)

MNaIl. 88. no.)

(veal bfrltl N-20-3 N-21.42

5. ASME Code.Section III, Division 1:

1986 None 1

N-L70-3I N-2143 (edmtionl (addenda dutel Wclass)

ICode Case no.1

"*I Component

'A' Barrel

'8' Barrel

'H' Barrel

'J' Barrel Stub Barrel Transition Cone Drawing #

IT.

Rev.

Mat'l Spec. #

6148E99 H02 03 SA-533 Type B CL2 6148E99 H03 03 SA-533 Type 8 CL2 6148E99 H04 03 SA-533 Type B CL2 6148E99 H05 03 SA-533 Type B CL.2 6148E99 H01 03 SA-533 Type B CL.2 6144E63 H03 03 SA-508 CL.3a Tensile Strength (Min.)

Nom Min*

1 tlll II I U 90 ksi 90 ksi 90 ksi Thickness 3.74" 3.74" 4.38' 3.24" 3.24!

3.88' 90 ksi 4.38" 3.88" 90 ksi 5.20' 4.700 90 ksi 3.350 3.31" 11' 1/3' 11' 1/3" 14'-3/4 14'Y.4 14' 11/16' 10' 1/3" 10' 1/30 9' 7/16" 9' 3/8' 7' 13/16" 7' 5/8'

  • 1 Nozzles, Inspection and Safety Valve Openings Purpose QTY.

Dia. (In)

Feedwater Nozzle Primary Nozzle Steam Outlet Auxiliary Feedwater Secondary Blowdown Secondary Shell Drain Sampling Tap Water Level Tap Primary Manway Secondary Manway Inspection Port Inspection Port Handhole Sludge Collector Weld Overlay:

Prir He*

No2 1

2 1

1 2

2 2

16 6

2 16' 31' 320 70 2" NPS 2' NPS 2" NPS 3/4"NPS 16' 16' 4'

How Reinforcement Type Attached Mat'[ Spec. #

Thickness Mat'l Weld End Forged Weld End Weld End Weld End Weld End Weld End Weld End Welded Integral Welded Welded Welded Welded Welded Welded SA-508 CL3a SA-508 CL3a SA-508 CL3a SA-508 CL.3a SA-508 CL.3a SA-508 CL.3a SA-508 CL.3a SA-508 CL3a

_SA-508 CL.3a SA-508 CL.3a 0.79' 5.17" 1-.31' 0.75' 0.79' 0.45' 0.54" 0.46' 5.94' 5.62' SA-508 CL.3 SA-508 CL.3 SA-508 CL.3 SA-508 CL.3 Location Secondary Primary Secondary Secondary Secondary Secondary Secondary Secondary Primary Secondary Secondary Secondary Secondary Secondary "nary side surface of the tube plate is overlaid with weld-deposited nickel-chromium-iron alloy. The Channel ad interior surfaces, including nozzles and manways, is overlaid with stainless steel weld deposit Primary zles include safe-ends of SA-336, CL.F 316LN material.

FORM N-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR VESSELS' As Required by the Provisions of the ASME Code,Section III. Division 1 Pg. 4 of 4

Westinghouse Electric Company, Pensacola Plant No. 5

1. Manufactured and certified by 8301 Scenic Highway, Route 90, Pensacola, Florida 32514-7810 (name and 4401113%

of N Certificate Motaeri

2. Manufacturedfor Carolina Power and Light Company. Shearon Harris Unit-l, RaleigRh.North

.name. and address of u,,°ch.ser.

Carolina 29065

3. Location of installation Shearon Harris Nuclear Power Plant. P.O. Box 165 State Road 1134 Steam

.na.e.and add*"S

Newhill, NC 27562-01625
4. Type:

Vertical Generator SG3L-12244 6149E35 Rev.2 64 1998 (hort.

or vert.)

(tank. jacketed. heat ex.)

[Cart. Holder's Sorti&l nO.)

CRNJ itawing no.i INhiI. SO. no.)

(yW*r b"- it1 N-20-3 N-2142

5. ASME Code,Section III, Division 1:

1986 None 1

N-474-i N-2143

[ed.1hon) laddenda dotea 4class.

Icooce Case

-a.)

Notes:

1)
2)
3)
4)
5) 6)

Unit received a full post weld heat treatment Unit received a full R.T. examination.

Post-hydro M.TJP.T. examination of Steam Generator performed.

Nozzle shipping caps are not part of this manufacturers data report One tube plugged at Row 114, Column 73, Side A & B.

"Temper Bead' weld repair after P.W.H.T. was performed to the flat surface/knuckle radius 90 degrees from stub runner near Column 70, Row 115 - to - Column 66, Row 115.

FORM N-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR VESSELS' As Required by the Provisions of the ASME Code. Section Ill, Division 1 Pg. 1 of 4

Westinghouse Electric Company, Pensacola Plant No.

5

1. Manufactured and certified by 8301 Scenic Highway, Route 90, Pensacola, Florida 32514-7810 fname and address of N Certificate Holder;
2. Manufactured for Carolina Power and Light Company, Shearon Harris Unit-i, Raleigh, North

]

and address 0o Purchaseri Carolina

3. Location of installation Shearon Harris Nuclear Power Plant, P.O.

Box 165 State Road 1134 Steam (name andaddress,

Newhill, NC 27562-01625
4. Type:

Vertical Generator SG3L-12245 6149E35 Rev.2 65

_ _1998 Ihomia. or sen.)

(tank. jacketed, heat ex.)

(Cen. Holder's serial no.1 (CRN) tdrawing no.1 INat'l. So. no.1

-1eai tidltj

5. ASME Code,Section III, Division 1:

1986 None 1

N-20-3 N-2142 leditioni (addenda datel (classi (Code Case no.)

Items 6-10 inclusive to be completed for single wall vessels, jackets of jacketed vessels, or shells of heat exchangers.

6. Shell:
  • 1
  • 1
  • 1
  • 1
  • 1 67' 7/8" Total Imat'l. Spec. no.J itensile strength) lont. thickness (in.)l Imm. design thickness fin.))

(dia. 30 Ili & n.il (length loveraill lIt & in.)l

7. Seams:

Molb Full Full5 (Iong.I (HT'l (AT) left. %)

(9gtrh)

(HT'I (RT)

InD. of courses)

8. Heads:SA-5 0 8 Cl3a 90 ksi N/A N/A hlal matl, Spec. no.)

Itensile strengthi i(bi iatTl. sOcc. no.)

tensile strengthi Location Crown Knuckle Elliptical Conical Hemispherical Flat Side to Pressure (top. bottom, ends)

Thickness Radius Radius Ratio Apex Angle Radius Diameter (convex or concave)

(a) I TOP I 3.85 N/Al N/A I 2:1 I

N/A N/A N/A I Concave

[ b, I fIi I

If removable, bolts used N /A Other fastening N /A (nat'l. spec. no.. size. quantity) odescribe or attach sketch)

9. Jacket closure: Girth Weld -

DBL Butt, Full P.W.H.T.; Full R.T.

(Oescribe as ogee & weld. bar. etc. If bar. give dimensions, describe or sketch)

10. Design pressure2 at max. temp. 600

. Min. pressure-test temp.

70

. Pneu.

h or comb. test pressure1482 PS_.

""psi)

(IF) 1F]

(psi]

Items 11 and 12 to be completed for tube sections.

11. Tubesheets:

SA-508 Cl 3a 129.38" 22.70" Welded (stationary. mat'l. Spec. no.)

Idia. in. (subject to press.)l ithickness (in.))

lattachment (welded. boltedil (floating. mat'I. Spec. no.)

Idia. (in.))

(thickness (in.))

(attachment)

12. Tubes:SB-163UNS06690 11/16"

.040" Nom.

6307 U

(mat'l. sec.

no.)

(00 (in.)l (thickness linches or gagell 1no..1 type Istraight or U)]

Items 13 to 16 inclusive to be completed for inner chambers of jacketed vessels, or channels of heat exchangers.

13. Shell:

(mat'l. Spec. no.)

(tensile strengthl

[nom. thickness (in.))

Imm. design thickness (in.))

(dii. 10 lIt. & in.ll (length loveraill ift & in.1l

14. Seams:

Girth Full Full (long. (welded. dbl., single)]

IHT (yes or nolI (RT)

(elf. %l Igirth)

(HT'i IRT)

(no. of courses)

15. Heads:

-S A -508 C l3a 90 k si (hI mat8:. spec. no.)

(tensile strengthl

[(b) mat'l. spec. no.1 (tensile strength(

](c) mat)l, spec. no.1 Itensile strengthl Crown Knuckle Elliptical Coia Nemisonencal Flat Side to Pressure Location Thickness Radius Radius Ratio Apex Angle Radius biameter (convex or concavel lal Top, bottom, ends I

i I

I I

lbblChannel I 5.26" I

I 1 62.81" I

Concave (c) Floating

.I If removable, bolts used Other fastening imat'l. spec, no.. Side. quantity)

Idescribe or attach sketchl 2 2485 PSIG 65 70 X

3107 PSIG

16. Design pressure 50

.. Min. pressure-test temp.

7 Pneu., y r comb. test pressure _

IDsisl IF)

(pFs u

(psi)

'If OOStweld heat treated.

"Lst other internal or external pressure with coincident temperature when applicable.

" Suoolemental information in form of lists. sketches, or drawings may be used provided (1) size is 8 Va x 11. 12) information in items 1 through 4 on this Data Report, is included ron each sneet. (3) each sheet is numoered and number of sneets is recorded at top of this form.

112/88)

This form 1E00038) may be obtained from Mhe Order Dept.. ASME. 22 Law Drive. Box 2300. Fairfield. NJ 07007-2300-

FORM N-1 (Back -

Pg. 2 of 4

)

Certificate Holder's Serial No.SG3 L-1 2245

17. Nozzles, inspection and safety valve openings:

Purpose Iiclel. %aHow Re~rinorcemnent outier. drain. etc.)

uantity Oia. or Size TvAe tached M

i.

Thocxness Marer.al Locat,,n

"*1 1

"1 1

I "1 1

  • 1

"*1

" 1

" 1 "1

I I

I I

I I I M I

I I

G I

I I

I ii I

I

[-

I I

I I

I

18. Supports: Skirt Lugs Legs_

Other.

Attached/integqral with tube plate (yes or no?

Iquanuity) lquiantityl Idescr~be)

Iwtnere & howl

19. Remarks: None Design specification certified by G.hV. Smith av.e.

c b

P.E. State Fc L d

Reg. no. 0045390 D e i g r e p o r c e rt f ie b yCF.L o k a tL R e g. n o. 0 0 4 4 0 4* 3 CERfTIFICATE OF SHOP COMPLIANCE We certify that the statements made in this report are correct this nuclear vessel conforms to the rules for construction of the ASME Code,Section III, Division 1.

Certificate of Authorization No.

N-1669 Expiress o rch i

c I, 2001 Date _

-__O__

-Name Westinqhouse Electric Co.

Sign__l WIN c.,tBfie, Ho(]lden m

R A n d L,

edorerseme ntatne r,

CERTIFICATE OF SHOP INSPECTION

1. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of SFlorida and employed by Arkwright Mutual Ins. Co.

of -WalItha m.

MA have inspected the component described in this Data Report on Wecertify that the statte that to the best of my knowledge and belief, the Certificate Holder has constructed this s component in ac cordance with the ASME Code,Section I II, Division 1.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied. concerning the component ýescribed in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injur~y or property damage or a loss of any kind arising from o canr

-*with this inspection.

cDateen-joaýt/folrSignned Commgned on oNBr"m ss 7245 N FL 328 W.- Y."

n* s lAutnoruzo i-,pectori (Nat'l. So. anc,.. a ooroe,,s, and stat or *oro. and no.n1 N/A CERTIFICATE OF FIELD ASSEMBLY COMPLIANCE We certify that the statements on this report are correct and that the field assembly construction of all parts of this nuclear vessel conforms to the rules of construction of the ASME Code, Section DtRo Division 1.

N Certificate of Authorization No.

Expires Date c Name bNaned Certificate HolderaSig ad acertficathe Aoldolol(authMCrizedS ren esenIDtivso N/Ak CERTIFICATE OF FIELD ASSEMBLY INSPECTION

1. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors an~d the State or Provirice of and employed by of have compared the statements in this Data Report with the described component and state that parts referred to as data items.,

not included in the certificate of ýhop inspection, have been inspected by me on and that to the best of my knowledge and belief the Certificate Holder has construe~ted and assembled this component in accordance with the ASME Code, Section Ill, Division 1.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the component described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any.kind arising from or connected with this inspection.

Date Signed Commissions SIAutnotized] Insoactorl INa'IL 8d. ihncl. endorsementsi and state or orov. and no.1

FORM N-1 CERTIFiCATE HOLDERS' DATA REPORT FOR NUCLEAR VESSELS As Required by the Provisions of the ASME Code.Section III, Division 1 Pa Westinghouse Electric Company, Pensacola Plant No.

5

1. Manufactured and certified by '8301 Scenic Highway, Route 90, Pensacola, Florida 32514-7810 (namn and address Of N Cartfl*late Holdowl
2. Manufacturedfor Carolina Power and Light Company. Shearon Harris Unit-1 Raleiqh. North inamne and address of Purenaser, Carolina 29065h

[....

f.......

Ca rolina 29 065

3. Location of installation Shearon Harris Nuclear Power Plant. P.O. Box 165 State Road 1134 Steam iname, ndad,,,es
Newhill, NC 27562-01625
4. Type:

Vertical Generator SG3L-12245 6149E35 Rev.2 65 1998

.tIhOz. o0 Gern.I ttank. aikated. heat e..l (Con. Holder's serial no.j ICRN) ldrawing no.j Nat'l.

  • d. no., )year l

N-20-3 N-2142

5. ASME Code, Section I11. Division 1:

1986 None 1

N-474-i 1,N-2143 (edition)

(addenda dotal (class)

(Coe Case no.;

Drawing #

IT.

Rev.

6148E99 6148E99 6148E99 H02 H03 H04 03 03 03 6148E99 H05 03 6148E99 H01 03 Transition Cone 6144E63 H03 03 Mar M....

Mi I SA-533 Type B CL.2 SA-533 Type B CL2 SA-533 Type B CL.2 SA-533 Type B CL2 SA-533 Type B CL2 SA-508 CL3a Tensile Strength 90 ksi 90 ksi 90 ksi Thickness Nom Min 3.74" 3.74' 4.38' 3.24' 3.24" 3.88' 90 ksi 4.38' 3.88' 90 ksi 5.20" 4.70" 90 ksi 3.35' 3.31' 1

11 14"

114,'/.

14' 11/16' Dia.

Overall Length 1' 1/3" 10' 1/3*

1' 1/3" 10' 1/3' 4' Y" 9' 7/16" 9' 3/8' 7' 13/16' 7' 5/8'

  • 1 Nozzles, Inspection and Safety Valve Openings Purpose How Zr-V as a Spe*. i I nlCKness QTY.

fia (ln*

Feedwater Nozzle Primary Nozzle Steam Outlet Auxiliary Feedwater Secondary Blowdown Secondary Shell Drain Sampling Tap Water Level Tap Primary Manway Secondary Manway Inspection Port Inspection Port Handhole Sludge Collector 1

2 1

8 2

2 2

16 6

2 16' 31' 32" 7'

2' NPS 1' NPS 2' NPS 34NPS 16' 16' 4"

2' Weld End Forged Weld End Weld End Weld End Weld End Weld End Weld End Reinforcement Welded SA-508 CL3a 0.79' Integral SA-508 CL3a 5.17' Welded SA-508 CL.3a 1.31' Welded SA-508 CL3a 0.75' Welded SA-508 CL3a 0.79' Welded SA-508 CL.3a 0,45" Welded SA-508 CL3a 0.54' Welded SA-508 CL3a 0.46' SA-508 CL.3a 5.94" SA-508 CL3a 5.62' S

S S.

S Mat'l Location A-508 CL3 Secondary A-508 CL.3 Primary A-508 CL.3 Secondary A-508 CL3 Secondary Secondary Secondary Secondary Secondary Primary Secondary Secondary Secondary Secondary Secondary Weld Overlay:

Primary side surface of the tube plate is overlaid with weld-deposited nickel-chromium-iron alloy. The Channel Head interior surfaces, including nozzles and manways, is overlaid with stainless steel weld deposit Primary Nozzles include safe-ends of SA-336, CL.F 316LN material.

  • 1 Component

'A' Barrel

'B' Barrel

'H' Barrel VJ Barrel Stub Barrel PC -.!of -

Mat'l Spe=c. #

Ik*l*+=l (* ^^ 44t "I"*:*1.....

FORM N-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR VESSELS*

As Required by the Provisions of the ASME Code.Section III. Division 1 Po. 4

4)

Nozzle shipping caps are not part of this manufacturer's data report.

.of 4

Westinghouse Electric Company, Pensacola Plant No. 5 8301 Scenic Highway, Route 90, Pensacola, Florida 32514-7810

1. Manulac~ured and certified by (rnt andO elss of N Ceonlhcate MlalI0.
2. Manufacturedfor Carolina Power and Light Company. Shearon Harris Unit-,

Raleigh. North n.m...

dr.., 01 P..

,i

"*'"Carolina 29065

3. Location of installation Shearon Harris Nuclear Power Plant, P.O. Box 165 State Road 1134 Steam ina.... ano.o..si
Newhill, NC 27562-01625 Vertical Generator SG3L-12245 6149E35 Rev.2 65 1998 IhOr.Z. or,erA.

tiank. ilCkoted. n*st ex.)

ICin. HIolder'3 $rlil no.1 ICRNI "lOwing no.0.1 MNi.

ld. no.)

yI..,l N:20:2, N-2142

5. ASME Code. Section IIl. Division 1:

1986 None I

N-2470-.

N-2143 Ieditioni laodenas il ell IC8.3so

[Code Ca.* no.

Notes:

1)

Unit received a full post weld heat treatment.

2)

Unit received a full R.T. examination.

3)

Post-hydro M.TAP.T. examination of Steam Generator was performed.

Pa_ /4

R/R# 01-02-200 ASME XI, CLASS 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions for the ASME Code Section XI

1.

Owner:

Carolina Power& Light Name P.O. Box 1551, Raleigh, N.C. 27602-1551 Address

2.

Plant:

Shearon Harris Nuclear Power Plant Name P.O. Box 165. New Hill. N.C. 27562-0165 Address

3.

Work Performed by:

Becon Construction Name P.O. Box 9, New Hill, N.C. 27562 Address

4.

Identification of System:

AUX-FEED WATER (SUPPORTS)

Date:

12/24/01 Sheet 1

of 8

IUnit 1 Repair Organization P.O. No., Job No., etc Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A

5.

(a) Applicable Construction Code: ASME SEC III Edition 1974 Addenda WINTER 76 Code Case N/A (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements: 1989

6.

Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Component Manufacturer Serial No.

Board Identification:

No.

See attached Addenda N/A Year Repaired ASME Built Replaced Code Or Stamped Replacement Yes/No

7.

Description of Work The existing Aux-feed water pipe and supports inside Bio-shield wall was removed and rerouted to the new location of the Aux-feed water nozzle on the new steam generator. New hangers were installed and some old hangers outside of the bio-shield wall were modified or parts replaced to accommodate the stress analayis on the pipe.

8.

Tests Conducted:

Hydrostatic El Pneumatic El Nominal Operating Pressure [E Other El Pressure psi Test Temp. -

  • F NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 % in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12/82)

Form NIS-2 rIeI ei I,.,e II se U IUi .vuv UOLO C.,,.,, La.

Applicable Manufacturer's Data Reports to be attached VT-3 was performed after the hanger modifications/installations.

R/R# 01-02-200 ASME X1, CLASS 2 Sheet 2 of 8

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the repair or replacement ASME Code, Section Xl.

Type Code Symbol Stamp NIA Certifi of Authorizati No. N/A Expiration Date NIA Signed -,i:ý,k--

Equipment Performance Supervisor Date 20 2

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Nnrth Cr*mlina and employed by Hartford Steam Boiler Inspection and Insurance Company of One State Street, Hartford, Connecticut 06102 have inspected the components described in this Owner's Report during the period 05-13-00 to 12-14-01

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. --

Commissions NC 1444NIAB Inspector's Signature National Board, State, Province, and Endorsements Date

-'" A6' 20 02--

Z1.

RemarKs

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet Sheet 3

of 8 Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board No.

Identification:

Built Replaced Code Or Stamped Replacement Yes/No AF-H-331 STRUT BERGEN NA NA B.P. 2100-12 UNK REPLACEMENT NO POWER CLAMP BERGEN NA NA B.P. 2600-12 UNK REPLACEMENT NO POWER AF-H-332 STRUT BERGEN NA NA B.P. 2100-12 UNK REPLACEMENT NO POWER CLAMP BERGEN NA NA B.P. 2600-12 UNK REPLACEMENT NO POWER AF-H-355 STUDS CSC NA NA HT. 15192 UNK REPLACEMENT NO 7/8" -9 x 5.75" HEAVY HEX Republic NA NA HT. 8994826 UNK REPLACEMENT NO NUT 7/8"-9 Technologies Int.

AF-H-336 SNUBBER BERGEN NA NA B.P. 2410-6 UNK REPLACEMENT NO POWER END BERGEN NA NA BP. 2003-3 UNK REPLACEMENT NO ATTACHMENT POWER U-BOLT BERGEN NA NA B.P. 6504-6 UNK REPLACEMENT NO POWER TS Leavitt Tube Co.

NA NA A-500 GR. B UNK REPLACEMENT NO 3" x 3" x 1/4" Inc.

HT. W07274 1/2" PLATE Corus NA NA UNK REPLACEMENT NO SA-36 HT. B1 P5527 1" PLATE Gulf States NA NA UNK REPLACEMENT NO SA-36 Steel, Inc.

HT. 7473991 AF-H-366 SNUBBER BERGEN NA NA B.P. 2540-15 UNK REPLACEMENT NO POWER CLAMP BERGEN NA NA BP. 2640-15 UNK REPLACEMENT NO POWER 3/4" PLATE Corus NA NA SA-36 UNK REPLACEMENT NO HT. BOX 7262 AF-H-367 STRUT BERGEN NA NA B.P. 2540-6 UNK REPLACEMENT NO POWER CLAMP BERGEN NA NA B.P. 2640-6 UNK REPLACEMENT NO POWER AF-H-678 SNUBBER BERGEN NA NA B.P. 2410-6 UNK REPLACEMENT NO POWER CLAMP BERGEN NA NA B.P. 2640-6 UNK REPLACEMENT NO POWER TS /" x 4" x 4" Bethlehem Steel NA NA A500 Gr. B UNK REPLACEMENT NO A500 Gr. B Corp.

HT. 841 N06520 1" PLATE Gulf States NA NA SA-36 UNK REPLACEMENT NO SA-36 Steel, Inc.

HT. 7473991 1/4" PLATE Corus NA NA HT. AOR0914 UNK REPLACEMENT NO SA-36 TS 1/2" x 6" x 6" Independence NA NA HT. D00659 UNK REPLACEMENT NO A500 Gr. B

. Tube Corp,

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet Sheet 4

of 8 Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board No.

Identification:

Built Replaced Code Or Stamped Replacement Yes/No 1"

PLATE Corus NA NA HT. B1P5527 UNK REPLACEMENT NO SA-36 1/2" PLATE US Steel Group NA NA HT. E04583 UNK REPLACEMENT NO SA-36 TS 1/4" x 3" x 3" PROVIDED BY NA NA HT.GF0413 UNK REPLACEMENT NO A500 Gr. B CP&L MRR #

YVR-3086 3/8" PLATE Bethlehem NA NA HT. T2128 UNK REPLACEMENT NO A572 Gr. 50 AF-H-679 STRUT BERGEN NA NA B.P. 2100-12 UNK REPLACEMENT NO POWER CLAMP BERGEN NA NA B.P. 2600-12 UNK REPLACEMENT NO POWER TS 1" x 4" x 4" Leavitt Tube Co.

NA NA HT.

UNK REPLACEMENT NO A500 Gr. B Inc 833L65720 AF-H-680 BEAM BERGEN NA NA B.P. 1047 UNK REPLACEMENT NO ATTACHMENT POWER SPRING CAN BERGEN NA NA B.P. 3400 UNK REPLACEMENT NO POWER HEX NUT BERGEN NA NA B.P. 5400 UNK REPLACEMENT NO POWER WELDLESS BERGEN NA NA B.P. 5130 UNK REPLACEMENT NO EYE NUT POWER CLAMP BERGEN NA NA B.P. 6150 UNK REPLACEMENT NO POWER THREADED BERGEN NA NA B.P. 5006 UNK REPLACEMENT NO ROD POWER 3/4" PLATE Corus NA NA HT. BOX UNK REPLACEMENT NO SA-36 7262 AF-H-681 SNUBBER BERGEN NA NA B.P. 2410-6 UNK REPLACEMENT NO POWER END ATTACH.

BERGEN NA NA B.P. 2003-3 UNK REPLACEMENT NO POWER END ATTACH.

BERGEN NA NA B.P. 1001 UNK REPLACEMENT NO POWER U-BOLT BERGEN NA NA B.P. 6504 UNK REPLACEMENT NO POWER 3/4" PLATE Corus NA NA HT. BOX UNK REPLACEMENT NO SA-36 7262 1" PLATE Gulf States NA NA HT. 7472446 UNK REPLACEMENT NO SA-36 Steel, Inc.

1-1/2" PLATE Gulf States NA NA HT. 7459350 UNK REPLACEMENT NO SA-36 Steel, Inc AF-H-292 RIGID STRUT BERGEN N/A N/A B.P. 2100-12 UNK REPLACEMENT NO POWER 6" PIPE BERGEN N/A N/A B.P. 2600-12 UNK REPLACEMENT NO CLAMP POWER AF-H-294 I

I RIGID STRUT BERGEN N/A N/A B.P. 2100-7 UNK REPLACEMENT NO POWER

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet Sheet 5

of 8 Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board No.

Identification:

Built Replaced Code Or Stamped Replacement Yes/No 6" PIPE BERGEN N/A N/A B.P. 2600-7 UNK REPLACEMENT NO CLAMP POWER AF-H-295 RIGID STRUT BERGEN N/A N/A B.P. 2100-7 UNK REPLACEMENT NO POWER 6" PIPE BERGEN N/A N/A B.P. 2600-7 UNK REPLACEMENT NO CLAMP POWER PL 1" GULF STATES N/A N/A 7472446 UNK REPLACEMENT NO STEEL AF-H-297 TS 8 X 3 X 1/2 LTV N/A N/A FF49404 UNK REPLACEMENT NO COPPERWELD PL 3/4" CORUS N/A N/A BOX7262 UNK REPLACEMENT NO AF-H-390 SWAY BERGEN N/A N/A B.P. 2100-7 UNK REPLACEMENT NO ARRESTOR POWER AF-H-391 3" PIPE BERGEN N/A N/A B.P. 2640-6 UNK REPLACEMENT NO CLAMP.

POWER 3" PIPE BERGEN N/A N/A B.P. 2640-6 UNK REPLACEMENT NO CLAMP.

POWER SNUBBER BERGEN/BASIC 41753 N/A B.P. 2540-6 UNK REPLACEMENT NO PSA SNUBBER BERGEN/BASIC 41754 N/A B.P. 2540-6 UNK REPLACEMENT NO PSA AF-H-392 SNUBBER BERGEN 41464 N/A B.P. 2540-6 UNK REPLACEMENT NO POWER 6" PIPE BERGEN N/A N/A B.P. 2640-6 UNK REPLACEMENT NO CLAMP POWER AF-H-670 1/4" PL CORUS N/A N/A AOR0914 UNK REPLACEMENT NO 1/2" PL CORUS N/A N/A B1 P5527 UNK REPLACEMENT NO 1/2" PL U.S. STEEL N/A N/A E04583 UNK REPLACEMENT NO 3/4" PL CORUS N/A N/A AOX2054 UNK REPLACEMENT NO 1" PL U.S. STEEL N/A N/A Y08953 UNK REPLACEMENT NO 1" PL GULF STATES N/A N/A 7472446 UNK REPLACEMENT NO STEEL TS 1/4X4X4 LEAVITT N/A N/A 841 N06520 UNK REPLACEMENT NO TS 1/4X4X4 LEAVIlTT N/A NIA 85919K UNK REPLACEMENT NO TS 1/2X6X6 IND. TUBE N/A N/A D00659 UNK REPLACEMENT NO CORP.

SNUBBER BERGEN/

41153 N/A B.P. 2410-6 UNK REPLACEMENT NO BASIC PSA

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet Sheet 6

of 8 Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board No.

Identification:

Built Replaced Code Or Stamped Replacement Yes/No 6" PIPE BERGEN N/A N/A B.P. 2640-6 UNK REPLACEMENT NO CLAMP POWER AF-H-671 6" PIPE BERGEN N/A N/A B.P. 2600-12 UNK REPLACEMENT NO CLAMP POWER RIGID STRUT BERGEN N/A N/A B.P. 2100-12 UNK REPLACEMENT NO POWER TS 1/4X4X4 LEAVIFT N/A N/A 832N34280 UNK REPLACEMENT NO TS 1/4X4X4 LEAVI'T N/A N/A 833L65720 UNK REPLACEMENT NO PL 1" GULF STATES N/A N/A 7472446 UNK REPLACEMENT NO STEEL.

AF-H-672 6" PIPE BERGEN N/A N/A B.P. 6150 UNK REPLACEMENT NO CLAMP POWER 1" EYE NUT BERGEN N/A N/A B.P. 5130 UNK REPLACEMENT NO POWER 1" ROD BERGEN N/A N/A B.P. 5006 UNK REPLACEMENT NO POWER TYPE B BERGEN N/A N/A B.P. 3400-12 UNK REPLACEMENT NO SPRING POWER 1" BEAM ATT.

BERGEN N/A N/A B.P. 1047 UNK REPLACEMENT NO POWER W4 X 13 BAYOU STEEL N/A N/A 71190 UNK REPLACEMENT NO 1" HEX NUT BERGEN N/A N/A B.P. 5400 UNK REPLACEMENT NO POWER AF-H-309 6" U-BOLT BERGEN N/A N/A B.P. 86210 UNK REPLACEMENT NO POWER 6" U-BOLT BERGEN N/A N/A B.P. 86210 UNK REPLACEMENT NO POWER PL 1" GULF STATES N/A N/A 7472446 UNK REPLACEMENT NO STEEL SNUBBER BERGEN 41387 N/A B.P. 2410-15 UNK REPLACEMENT NO POWER SNUBBER BERGEN 41399 N/A B.P. 2410-15 UNK REPLACEMENT NO POWER REAR BERGEN N/A N/A B.P. 2003-10 UNK REPLACEMENT NO BRACKET POWER TS 5 X 3 X 1/4 SOUTHLAND N/A N/A S10152 UNK REPLACEMENT NO TUBE INC.

PL 1/4" CORUS N/A N/A AOR0914 UNK REPLACEMENT NO 1-1/2" PIPE CP&L PN.

N/A N/A 294072 UNK REPLACEMENT NO 51414480 AF-H-311 SNUBBER BERGEN 40257 N/A B.P. 2540-6 UNK REPLACEMENT NO POWER TS 4 X 4 X 3/8 UNITED N/A N/A Y05656 UNK REPLACEMENT NO STATES STEEL,_II__

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet Sheet 7

of 8 Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board No.

Identification:

Built Replaced Code Or Stamped Replacement Yes/No PL 1/4" CORUS N/A N/A AOR0914 UNK REPLACEMENT NO END ATTACH.

BERGEN N/A N/A B.P. 2003-3 UNK REPLACEMENT NO POWER AF-H-362 SNUBBER BERGEN/BASIC 41390 N/A B.P. 2410-15 UNK REPLACEMENT NO

-PSA 6" PIPE BERGEN N/A N/A B.P. 2600-10 UNK REPLACEMENT NO CLAMP POWER W4 X 13 BAYOU STEEL N/A N/A 71190 UNK REPLACEMENT NO CORP.

PL 1/2" CORUS N/A N/A B1P5527 UNK REPLACEMENT NO PL 1/4" CORUS N/A N/A AOR0914 UNK REPLACEMENT NO AF-H-492 7/8" NUT CP&L YVR-3062 N/A N/A 73286296 UNK REPLACEMENT NO 7/8" ROD CP&L YVR-3069 N/A N/A NAN UNK REPLACEMENT NO AF-H-673 SNUBBER BERGEN 40260 N/A B.P. 2410-6 UNK REPLACEMENT NO POWER 6" PIPE BERGEN N/A N/A B.P. 2600-7 UNK REPLACEMENT NO CLAMP POWER TS 6 X 6 X INDEPENDENCE N/A N/A D00659 UNK REPLACEMENT NO 1/2" TUBE TS 6 X 4 X LTV N/A N/A Y88651 UNK REPLACEMENT NO 1/2" COPPERWELD TS 4 X 4 X 1/2 LEAVITT N/A NIA 833L65720 UNK REPLACEMENT NO TS 4 X 4 X BETHLEHEM N/A NIA 841N06520 UNK REPLACEMENT NO 1/4" STEEL PL 1/4" FERALLOY N/A N/A 1106933 UNK REPLACEMENT NO PL 1/4" CORUS N/A N/A AOR0914 UNK REPLACEMENT NO PL 1/2" CORUS N/A N/A B1 P5527 UNK REPLACEMENT NO PL 1" GULF STATES N/A NIA 7473991 UNK REPLACEMENT NO STEEL PL 1-1/2" CORUS N/A N/A AIN0480 UNK REPLACEMENT NO AF-H-674 6" PIPE BERGEN N/A N/A B.P. 2600-12 UNK REPLACEMENT NO CLAMP POWER RIGID STRUT BERGEN N/A N/A B.P. 2100-12 UNK REPLACEMENT NO POWER PL 1/2" GARY WORKS N/A N/A E04583 UNK REPLACEMENT NO PL 1" GULF STATES N/A N/A 7472446 UNK REPLACEMENT NO STEEL

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet Sheet 8

of 8 Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board No.

Identification:

Built Replaced Code Or Stamped Replacement Yes/No TS 4 X 4 X LEAVITT N/A N/A 832N34280 UNK REPLACEMENT NO 1/4" TS 4 X 4 X LEAVITT N/A N/A 833L65720 UNK REPLACEMENT NO 1/2" AF-H-675 SNUBBER BERGEN 40261 N/A B.P. 2410-6 UNK REPLACEMENT NO POWER 6" PIPE BERGEN N/A N/A B.P. 2640-6 UNK REPLACEMENT NO CLAMP POWER PL 1" GULF STATES N/A N/A 7472446 UNK REPLACEMENT NO STEEL 3/4" HILTI HILTI N/A N/A PN 00045382 UNK REPLACEMENT NO HILTI GROUT HILTI REQ. 146 N/A LOT UNK REPLACEMENT NO (CPL) 4209261461 AF-H-676 SNUBBER BERGEN 41393 N/A B.P. 2540-15 UNK REPLACEMENT NO POWER 6" PIPE BERGEN N/A N/A B.P. 2640-15 UNK REPLACEMENT NO CLAMP POWER TS 6 X 6 X INDEPENDENCE N/A N/A D00659 UNK REPLACEMENT NO 1/2" TUBE TS 6 X 3 X INDEPENDENCE N/A N/A 116425 UNK REPLACEMENT NO 3/8" TUBE PL 1/2" CORUS N/A N/A B1P5527 UNK REPLACEMENT NO PL 1-1/2" CORUS N/A N/A AIN0480 UNK REPLACEMENT NO AF-H-677 6"PIPE BERGEN N/A N/A B.P. 2640-15 UNK REPLACEMENT NO CLAMP POWER SNUBBER BERGEN 41391 N/A B.P. 2540-15 UNK REPLACEMENT NO POWER TS 6 X 6 X 1/2 LTV N/A N/A 57789 UNK REPLACEMENT NO COPPERWELD PL 1/4" CORUS N/A N/A AOR0914 UNK REPLACEMENT NO PL 1/2" CORUS N/A N/A BIP5527 UNK REPLACEMENT NO i

i i

f i

i i

4-4 4

4

+

4-4-

+/-

+

4 1

1

+/-

+

+

4 4

+

1

+

+

4 4

4

+

+

R/R# 01-02-201 ASME Xl, CLASS 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions for the ASME Code Section XI

1.

Owner:

Carolina Power & Light Name P.O. Box 1551, Raleigh, N.C. 27602-1551 Address

2.

Plant:

Shearon Harris Nuclear Power Plant Name P 0 Rny 1 6A New Hill N C 27562-0165 Date: 12/24/01 Sheet 1 of 3

Unit 1 Address Repair Organization P.O. No., Job No., etc

3.

Work Performed by:

Becon Construction Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. Box 9, New Hill, N.C. 27562 Address Expiration Date N/A

4.

Identification of System AUXILIARY FEEDWATER, (AFW) PIPING

5.

(a) Applicable Construction Code: ASME Sec.lll Cl. 2 Edition 1974 Addenda Winter 76 Code Case N/A (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements: 19 89 Addenda NIA

6.

Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board Identification:

Built Replaced Code No.

Or Stamped Replacement Yes/No 6" SCH. 80, SA B.F. SHAW 2AF6-93SAB-N/A ISO. SK-2001 REPLACEMENT YES 106 GR.B PIPE 1

SPOOL 9700807-M-2006 6' SCH. 80, SA B.F. SHAW 2AF6-59SAB-N/A ISO. SK-2001 REPLACEMENT YES 106 GR.B PIPE 1-A SPOOL 9700807-M-2006 6" SCH. 80, B.F. SHAW 2AF6-59SAB-N/A ISO. SK-2001 REPLACEMENT NO SA234 WPB-S, 1-B 450 ELL 9700807-M-2006 6" SCH.120, B.F. SHAW 2AF6-92SAB-N/A ISO. SK-2001 REPLACEMENT YES SA106 GR. C 1-9700807-M-2007 PIPE SPOOL 6" SCH.120, B.F. SHAW 2AF6-07SAB-N/A ISO. SK-2001 REPLACEMENT YES SA106 GR. C 1-A 9700807-M-2007 PIPE SPOOL 6" SCH.120, B.F. SHAW 2AF-07SAB N/A ISO. SK-2001 REPLACEMENT YES SA106 GR. C B

9700807-M-2007 PIPE SPOOL

R/R# 01-02-201 ASME XI, CLASS 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet Sheet 2 of 3 Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board No.

Identification:

Built Replaced Code Or Stamped Replacement Yes/No 6" SCH.80, B.F. SHAW 2AF6-91SAB-N/A ISO. SK-2001 REPLACEMENT YES SA106 GR. B 1

9700807-M PIPE SPOOL 2008 6" SCH.80, B.F. SHAW 2AF6-60SAB-NA ISO. SK-2001 REPLACEMENT YES SA106 GR. B PIPE SPOOL 1-A 9700807-M 2008 6" SCH. 80, B.F. SHAW 2AF6-60SAB-N/A ISO. SK-2001 REPLACEMENT NO SA234 WPB-S, 1-B 450 ELL 9700807-M 2008 6" SCH.80, B.F. SHAW 97807-M-N/A ISO. SK-2001 REPLACEMENT YES SA106 GR. B 2025-SOI PIPE SPOOL 9700807-M 2025 6" SCH.80, B.F. SHAW 97807-M-N/A ISO. SK-2001 REPLACEMENT YES SA106 GR. B 2026-S01 PIPE SPOOL 9700807-M 2026 6" SCH.80, B.F. SHAW 97807-M-N/A ISO. SK-2001 REPLACEMENT YES SA106 GR. B 2027-S01 PIPE SPOOL 9700807-M 2027 Description of 4

L 4

4 4 4 4

4 4

4

+ REMOVE AND REPLACE AFW PIPING IN MST AND RCB.

8.

Tests Conducted:

Hydrostatic [E Other 0l Pneumatic Dl Nominal Operating Pressure 0 Pressure psi Test Temp._

_F NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 / in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12/82) 7.

R/R# 01-02-201 ASME XI, CLASS 2 Form NIS-2 Sheet 3

of 3

9.

Remarks Reference line 6 for code data reports.

Applicable Manufacturer's Data Reports to be attached VT-2 performed per requirements of Code Case N-416-1 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repkIc.i;mPnt conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorizat n No. N/A Expiration Date N/A Signe dcn I __-

//KEquipment Performance Supervisor Date

_,20 07-

__TOwný' Owirý Desifnee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Companv of One State Street.

Hartford, Connecticut 06102 have inspected the components described in this Owner's Report during the period 05-13-00 to 12-14-01

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NC 1444NIAB Inspector's Signature National Board, State, Province, and Endorsements Date 2'

20

R/R# 01-02-202 ASME Xi, CLASS 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions for the ASME Code Section XI

1.

Owner:

Carolina Power& Light Name P.O. Box 1551, Raleigh, N.C. 27602-1551 Address

2.

Plant:

Shearon Harris Nuclear Power Plant Name P-.p Box 165. New Hill-N.C. 27562-0165 Address

3.

Work Performed by:

Becon Construction Name P.O. Box 9, New Hill, N.C. 27562 Date:

12.04.01 Sheet 1

of 2 Unit 1 Repair Organization P.O. No., Job No., etc Type Code Symbol Stamp N/A Authorization No. N/A Address Expiration Date N/A

4.

Identification of System:

MAIN STEAM ASME III, CLASS 2

5.

(a) Applicable Construction Code: ASME Sec.lll Edition 1974 Addenda Winter 76 Code Case N/A (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements: 19 89 Addenda NIA

6.

Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board Identification:

Built Replaced Code No.

Or Stamped Replacement Yes/No 2" Sch 80 Pipe Gulf States Tube N/A N/A Ht# 710144 Unk REPLACEMENT NO SA-106 Gr.B

7.

Description of Work 2" pipe 7 1/?" Iq replaced damaged spool on "C" loop vent pipe between tee & weld-o-let.

8.

Tests Conducted:

Hydrostatic El Pneumatic El Nominal Operating Pressure 0 SOther []

Pressure psi Test Temp.

OF NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1% in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12/82)

R/R# 01-02-202 ASME XI, CLASS 2 Sheet 2 of 2

Applicable Manufacturer's Data Reports to be attached VT-2 Derformed oer reauirements of Code Case N-416-1 Form NIS-2 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp MIA Certificate of Authorization

o.

N/A Expiration Date N/A Signed

=

44LEuipment Performance Supervisor Date i,

20 0-2 r *ner or b*'wner/esighlee, Title Dae I*,

0L)2 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Insoection and Insurance Comoanv of One State Street, Hartford-Connecticut 06102 have inspected the components described in this Owner's Report during the period 05-13-00 to 12-14-01

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Commissions NC 1444NIAR Inspectors Signature National Board, State, Province, and Endorsements Date 20.

n

.0l All D

1.

AIII1 1 4

l l

+*l/

l 4~IIIIl~lLl I-

_Vy

R/R# 01-02-203 ASME XI, CLASS 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions for the ASME Code Section XI

1.

Owner:

Carolina Power & Light Date:

12/24/01 Name P.O. Box 1551, Raleigh, N.C. 27602-1551 Sheet 1

of 3

Address

2.

Plant:

Shearon Harris Nuclear Power Plant Unit 1 Name P.O Box 165. New Hill, N.C 27562-0165

.3R.11 Address Repair Organization P.O. No., Job No., etc

3.

Work Performed by:

Becon Construction Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. Box 9, New Hill, N.C. 27562 Address Expiration Date N/A

4.

Identification of System: STEAM GENERATOR BLOWDOWN (LINE # 2BD3-218SN-1)

5.

(a) Applicable Construction Code ASME III Edition 1974 Addenda Winter 1976 Code Case N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:

1989 Addenda N/A

6.

Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board Identification:

Built Replaced Code No.

Or Stamped Replacement Yes/No PIPE 3" VALLOUREC &

N/A N/A HT # 344533 UNK.

REPLACEMENT NO MANNESMANN SA 335 GR P22 TUBES 3" ELBOW 90 TAILOR FORGE N/A N/A HT# LWKQ-1 UNK.

REPLACEMENT NO DEGREE STAINLESS LWKQ-2 SA 234 WP22 SMLS.

7.

Description ofWork steam GP-nratnr Rlowdown linp # 9RI3-21RSN-1 was partially removed rnd then reinstsIIed/modified

8.

Tests Conducted:

Hydrostatic El Pneumatic El Nominal Operating Pressure 0 Other El Pressure __

psi Test Temp. OF, NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12/82)

RIR# 01-02-203 ASME XI, CLASS 2 Sheet 2 of 3

Applicable Manufacturer's Data Reports to be attached VT-2 performed Der reauirements of Code Case N-416-1 Form NIS-2 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPLAC*M*NT conforms to the rules of the repair or replacement ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A I

/Art Equipment Performance Supervisor Date

'//(

,20 0w1ef-t'*

Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North.aralinn and employed by Hartford Steam Boiler Insoection and Insurance Comoanv of One State Street.

Hartford Connecticut 06102 have inspected the components described in this Owner's Report during the period 05-13-00 to 12-14-01

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this r'_tureNationaBoardCommissions NC 1444NIAE Inspector's Signature National Board, State, Province, and Endorsements Date

-,ý 20 0 0

.4, 0

f-I; r_ f^

A A f 14 U.

ema s

R/R# 01-02-203 ASME Xl, CLASS 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet Sheet 3

of 3

Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board No.

Identification:

Built Replaced Code Or Stamped Replacement Yes/No 3" ELBOW 45 TAILOR FORGE N/A N/A HT# LWKQ-2 UNK.

REPLACEMENT NO DEGREE STAINLESS SA 234 WP22 SMLS.

3" X 3 4" SW WFI N/A N/A HT# 2050ANC UNK.

REPLACEMENT NO PIPET SA-182 GR.F22 4" x 3" RED TAILOR FORGE N/A N/A HT# LVNU-1 UNK.

REPLACEMENT NO STAINLESS SA 234 WP22 SMLS.

4" 90 DEGREE TUBE N/A N/A HT# 676L UNK.

REPLACEMENT NO ELBOW FORGINGS OF SA-234 GR AMERICA WPB 2" PIPE GULF N/A N/A HT#7526379 UNK REPLACEME NO STATES TUBE SA-335 NT GR.P22 3" X 2" TAILOR FORGE N/A N/A HT# LWKQ-2 UNK.

REPLACEMENT NO REDUCER STAINLESS SA 234 WP22 SMLS.

R/R# 01-02-204 ASME Xl, CLASS 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions for the ASME Code Section Xl

1.

Owner:

Carolina Power & Light Date:

12/24/01 Name P.O. Box 1551, Raleigh, N.C. 27602-1551 Sheet 1

of 2

Address

2.

Plant:

Shearon Harris Nuclear Power Plant Unit 1 Name P.O-Box 165_ New Hill. NC_ 27562-0165 Address Repair Organization P.O. No., Job No., etc

3.

Work Performed by:

Becon Construction Type Code Symbol Stamp N/A Name Authorization No.

N/A P.O. Box 9, New Hill, N.C. 27562 Address Expiration Date N/A

4.

Identification of System: STEAM GENERATOR BLOWDOWN (LINE # 2BD4-2SN-1)

5.

(a) Applicable Construction Code ASME Ill Edition 1974 Addenda Winter 1976 Code Case N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:

1989 Addenda NIA

6.

Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board Identification:

Built Replaced Code No.

Or Stamped Replacement Yes/No PIPE 4" US STEEL N/A N/A HT# B86365 UNK.

REPLACEMENT NO GROUP SA 106 GR. B 4" X 2" BW LADISH N/A N/A HT# JL6SH1 UNK.

REPLACEMENT NO REDUCER

7.

Description of Work Stearm Gn.nprntor Rlnwdnwn linp # 2RIl4-25'N-1 was partially removed and then reinstalled/modified

8.

Tests Conducted:

Hydrostatic [I Pneumatic 5 Nominal Operating Pressure 0 Other [I Pressure_

psi Test Temp. °F NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1 in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12/82)

R/R# 01-02-204 ASME XI, CLASS 2 Form NIS-2 Sheet 2 of 2

9.

Remarks Reference line 6 for code data reports.

Applicable Manufacturer's Data Reports to be attached VT-2 performed per requirements of Code Case N-416-1.

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the repair or replacement ASME Code,Section XI.

Type Code Symbol Stamp NIA Certificate of Authorizatio No.

N/A Expiration Date N/A Signed nuiment Performance Supervisor Date

_ige20 6Tt CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North rarnlina and employed by Hartford Steam Boiler Inspection and Insurance Company of One State Street.

Hartford-Connecticut 06102 have inspected the components described in this Owner's Report during the period 05-13-00 to 12-14-01

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection Commissions NC 1444NIAR Inspectors Signature National Board, State, Province, and Endorsements Date 20 :;' 2---

R/R# 01-02-205 ASME XI, CLASS 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions for the ASME Code Section XI

1.

Owner:

Carolina Power & Light Date: 12/24/01 Name P.O. Box 1551, Raleigh, N.C. 27602-1551 Sheet 1 of 2

Address

2.

Plant:

Shearon Harris Nuclear Power Plant Unit 1 Name P.O. Box 165. New Hill, N.C. 27562-0165 91638 Address Repair Organization P.O. No., Job No., etc

3.

Work Performed by:

Becon Construction Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. Box 9, New Hill, N.C. 27562 Address Expiration Date N/A

4.

Identification of System: STEAM GENERATOR BLOWDOWN (LINE # 2BD4-3SN-1)

5.

(a) Applicable Construction Code ASME III Edition 1974 Addenda Winter 1976 Code Case N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Addenda N/A

6.

Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board Identification:

Built Replaced Code No.

Or Stamped Replacement Yes/No VALVE 4" BORG WARNER 58784 or N/A 435JAB2-006 1980 REPLACEMENT YES GATE 900#

69697 or 1981 69698 SA 105 1981 4" PIPE US STEEL N/A HT# B86365 REPLACEMENT NO GROUP SA-106 GR.B 36-3X1 3000#

WFI N/A N/A HT# 468 UNK.

REPLACEMENT NO SW PIPET SA 105

7.

Description of Work Ste*m G neiratnr RInwdown lint- # 2RI')4-ISN-1 wa pnrtinfly rpmovv*d qnd then reinstalled/modified

8.

Tests Conducted:

Hydrostatic El Pneumatic El Nominal Operating Pressure [

Other E0 Pressure__ psi Test Temp. IF NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 % in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12/82)

R/R# 01-02-205 ASME XI, CLASS 2 Sheet 2 of 2

Form NIS-2

9.

Remarks Reference line 6 for code data reports Applicable Manufacturer's Data Reports to be attached VT-2 performed per requirements of Code Case N-416-1.

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this RFPLA(FMFNT conforms to the rules of the repair or replacement ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorizatio N/A Expiration Date N/A Signed *'Equipment Performance Supervisor Date

_,20 2,

ner o ne esig hee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Qarnlina and employed by Hartford Steam Boiler Inspection and Insurance Company of One State Street.

Hartford, Connecticut 06102 have inspected the components described in this Owner's Report during the period 05-13-00 to 12-14-01

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NC 1444NIAR Inspector's Signature National Board, State, Province, and Endorsements

Date,

'/'-

s' 20

BOOK#O G1OQ FORM NFV-1 N CEIMmRCATE HOLDERS DATA REPORT FOR NUCLEAR PUMPS OR VALVES' As Required by this Provisions of this ASME Code. Siection Ill. Div. I

1. manufactuired by !Ih=l*Z V&lV* Div.,Borg-WArns r, 7500 Tyrc~w A-Va.,

Van Nqyz, Citlif.

(Name and Madress of N Certificate molder) 2-.Manufacturad forWashilngtot Public Power SuI~nv System. Richiand. Washinirto 99352 iNme and Addes of PUrcWfiee rOWner Washington Publtic Power S upplys

3. Location of Installation Svstem. Near SATSOP. Southesatern Grays F~rbor Count-.- WOa9hincton as) Mode No..

Series No.

or Type (b) 14 Certificate Hoidef'S Serial 140.

Nommnal Inlet Size 4______

Outlet Size 4______

(inchl 4,ncn (c) Canadian Registration No.

(d) Drawiing No.

(f) Nat).

(of Cats 8d. No.

1q) Year Built

./)

900#~

69697 & 69698 N/A 435JAB2-006 2

N/A 1981 (2)

(3)

(41 (51 (9)

Tha 'valves axe das~igned to andiAs a fluid meda which inludes steam, water 5

i~eAn~ta nr~euiA

-tt, Pnte I azinoelzta with at -RadB1 h

6i~ret oesrivoton 91 seorvie far iwhich ?quacmer we$~a~pd tempSZjtur 1Irhs~su rating of _tbL*

mkili is stated=n.ow 2000 475

6. Oesign Conditions 2160 psa 100

'F or Valve Pressure Class (Pramuiel lTe,nPemaures

7. Cold Working Pressure...

21J60D.... -pea 00'F.

8-. Pressure Retaining Paca NIA 1

Mart No.

I Merenat Soec. No.

I Manufacturer I

F-to) Castings Gate-Code IT27 SA 351 CF8M Vulcan Steel._

1T60 1 (bl Forgings

,B-ody-Code 4J09

.,- Boannet-Code 4F47 SA 10 5

4.

5 Jorgensen Steel

4.

9 SA 105 Coxu~ton Forge ck-Code 4A29 jSA 105 Shultz Steel

., Ne I Weld Can-Code IX7C SA 105 Compton Forge Retainer-Code 2PO31SA 105

=

orgensen Steel I_______

41108 Couumton Forge i

(I IFor manually opeated valives only.

Supplemental steets in form of lists. sketches or drammings may b* used.provided (11 siz is 8-ii& x 11-. t2) information in items i. z and S an twt~4 Oate Report it inctuded an each shoeet and (31 eaceM nbrdad ubro t.t is recorded at tog at this IforM fv1r i av eog~

3 (1om7 Th~e form (E00037) may be ebtifldd fron T"a Order OeP t.L 47t lffN.Y IMame end A~dresal

4. Pump or Val" Gzitp Valve I

--



wy.1 

CAMLI

-o~a Sw Drainl pipe-Code 3L89 SA 106 GR B Kilqby rubs "9.

MA ow auk5 ow-.t "a 2200 am.

C11RTMAT CP CAMPIUAMC1 Weowtily tha Via gastoWne nude fIn this i~wpo

&V 00fft Md VitMU

-u%3 orIP 01voue. cw~hmw to Vi Ano 0ongwycon of me AS~*! Cade for Nucear Poww Plant Carntimum~

Secdon M. 06W. 1 5 Ai Ift Wnter

'76 Sigedlielm= Valve Dir..Jarz Uaxusr b

CM OCA11OU OP DISS al M to m ofXY Bor Ia~x Vat 7500 TTM kyT., *j fte

~

.ca.

91409 Su w~is 46"t~ (Cau 04 afyt VA at~

N/IA assig spedflooadoii cordfled by III Alvin C. CINg KSm-Wash.

Re. 14 156109NI sh mulr mqtlsed bw 41) 1/

(1) sanu0ns " ft*ifd. lide Aws

06.

~1CE~ATE OF P b48 PGCT10N

1. th. wavidon"wd h*WkV1 a vead aswoW imei IaW by Me. Naleftel 26.

UOFh "WSd Pnisun Vese bvscmr W4d L'. ibmf or Pmwoviraw of CallforMA

,.w 811P bLmbigu' S tgual Cainl.

of djraLsZUU~SL=....he"

' no thei punp, at valve. deeabed in Uih.-0.W 111pot an gruotd thiswm. or~o valveA.

In osofflnc wi61 a" ABSd! Coad Sectin gL.

By din~g fails worflbm.e netide' Un I iv not Ws wtiavwmaes i~

any wwuwitvy tpri~ or i ipli oind.

amnk U'. sqglpla donin~db eUt this 0eM lo.

Fwdiermomp 46wlhr On. Inpevem nrw hio ampieday shed be U&Woi I* ally rnn'www r anporumn iLaw a pfosatl dw'ww ow sam tofseq kind arime, berni or 00M'.ld umittfi WVioma*L

~~Ax

/7fr-t A.

MRWRR yvlz - oo ?

YK.~.**PAG E

.. of

  • ~.m

~~'~ird cERT11ICATE HOLDERS-DATA REPORT FOR NUCLEAR PUFMP OR VALVES As Req~uired bry the PrOwisons of the ASME Code. Section Ifll DPiv I P-iF'

,:ee rema

!uc1Azr Valve D iyorg Waz-nax, 7500 Tyrw Ave., Van Thy, Ca2.if.

(Nam~e anld Address of h Certificate Holder)

.Wasbinirton Public Power Supnly System. Ri~chland. washinton 99352 Utwne endAdorema at w%,osa..f or Washi~ngt on Publtic Power Sup iv D eation* of Instalflation System, Near SATSOP, Southeastr C&=

-Er~

tv -

afthing on (ftm4 and Addrvew Crate Valve (b)MNCertificate Holder's Serial No0.

(cl Reg Nomninal Inlet Site 14 ixtration (d) rMkrl

)Ya No DawN~ DATE ff a'

i)Ya N.No.

(.tfta-c SCd. No.

Suitt 5S783-513764 435JAB2--;006 2

Thgt valvas axe a4esimed to b-d1z a fIlszU nedia which. ixcluds£tA, aa S.

1850

.4 C. Design Conditions 2160 1___

P.eerol PS Tern

7. Cold Working Pressure 216

-pit io00F.

& Pressujre Retaining Pieces Mark 11o.

1 Material Spar-N40.

{____________

Rana t

¶ 4

9 4

SA 351 F8M Waukesha Frdv. / Vilcan Steel

- D~esignl cona i: i.ons

¶ I2000 psi 4745

___________i________________

______________~2160 100 (b) Forging*

Bod-Corde 4A59

!nornet-Code _2P03 Nsa-cl-Code 4A29 I-1eld-Can-Code ITC SA 105 I

I I

4 5A 1t

Jorzensen Steel Jorensen Steel SA 10----------

_____________Steel_

.RA 1O5S

A



I b

Shultz Steel

.Tni-'enen Steel IJort'eflsef Steel (i

o aulyopersatd vehivet only.

K QLI ve

,~toos-(

Suoeotlshoots in forn of ties.x sketches of drawiiings may b~e used 4provided (I)

~

11 2

iofnatli itemsa 1, 2 and 5 an this Data Report is included m% each sheet. and 43) *ach shoot ifA t

and pgap Y~et o

is recorded at too of this form.I A

d This fwmj 46-000371 n

1. Manufactured, by 0

4.. Pump or Volvo (a) ModelNo..

Saries No.

or Typo (2)

(3)

(6)

(7)

(8)

(a) Castings 0 rM -

V=1"r Valve Div. Jýorg 'Wzmnar, 7500 Tyrame Ave., VAm Nuys, calif

._ 3FC32 e

SA 351 CTBM

-Cde 1U43 A

25 Jor,-ensen Steel S

IL t Z:

3 I N- /A G t 2

UX..

CD.,-

fr tA ý 0

R/R# 01-02-206 ASME X1, CLASS 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions for the ASME Code Section XI

1.

Owner:

Carolina Power & Light Name P.O. Box 1551, Raleigh, N.C. 27602-1551 Address

2.

Plant:

Shearon Harris Nuclear Power Plant Name P 0 Rny 1AS Mlw Hill N r*. ?7r75-n1R.r, Date:

12/24/01 Sheet 1

of 3

Unit 1 Address Repair Organization P.O. No., Job No., etc

3.

Work Performed by:

Becon Construction Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. Box 9, New Hill, N.C. 27562 Address Expiration Date N/A

4.

Identification of System: STEAM GENERATOR BLOWDOWN (LINE # 2BD2-67SN-1)

5.

(a) Applicable Construction Code ASME III Edition 1974 Addenda Winter 1976 Code Case N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:

1989 Addenda N/A

6.

Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board Identification:

Built Replaced Code No.

Or Stamped Replacement Yes/No PIPE 2'"

GULF STATES N/A N/A HT # 710144 UNK.

REPLACEMENT NO VISION METALS SA 106 GR B 2" SW BONNEY FORGE N/A N/A HT# 9182 UNK.

REPLACEMENT NO COUPLING SA 105

7.

Description of Work Ste.am Generator Rlnwdown linep f 9Rn?2-675N-1 was partially rmno_*vtd and then reinstalled/modified

8.

Tests Conducted:

Hydrostatic El Pneumatic El Nominal Operating Pressure [

Other El Pressure__ psi Test Temp. IF NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 % in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12/82)

R/R# 01-02-206 ASME X1, CLASS 2 Sheet 2 of 3

n fl....,....4...



Una £t mt ratio rioto ronarte Applicable Manufacturer's Data Reports to be attached VT-2 performed per requirements of Code Case N-416-1.

Form NIS-2 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this RPI ACG:MENT r.onforms to the rules of the repair or replacement ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization

o.

NIA Expiration Date N/A Signed A

/!- iEquipment Performance Supervisor Date 20 0 ner or 0ner' sig ee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Nnrth Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of One State Street.

Hartford, Connecticut 06102 have inspected the components described in this Owner's Report during the period 05-13-00 to 12-14-01

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NC 1444NIAR


I-spector's Signature Date

/

20 0 U.

Remaims National Board, State, Province, and Endorsements

R/R# 01-02-206 ASME XI, CLASS 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet Sheet 3

of 3 Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board No.

Identification:

Built Replaced Code Or Stamped Replacement Yes/No 2" X 2" X 3/4" BONNEY N/A N/A HT# 75509 UNK.

REPLACEMENT NO RED. TEE FORGE SA 105 4" X 2" LADISH CO.

N/A N/A HT# JL6SH1 UNK.

REPLACEMENT NO REDUCER SA 234 WPB I

I 1

1

__.1.

1 t

t I

t

-t t

I I

1 1

1 r

I 1-1 1

1 1

r I

t 1

1 I

1

+

I 1-1 1

1 1

R/R# 01-02-207 ASME X1, CLASS 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions for the ASME Code Section Xl

1.

Owner.

Carolina Power & Light Name P.O. Box 1551, Raleigh, N.C. 27602-1551 Address

2.

Plant:

Shearon Harris Nuclear Power Plant Name P.O. Box 165. New Hill, N.C. 27562-0165 Address

3.

Work Performed by:

Becon Construction Name P.O. Box 9. New Hill. N.C. 27562 Date:

12/24/01 Sheet 1

of 3

Unit 1 Repair Organization P.O. No., Job No., etc Type Code Symbol Stamp N/A Authorization No.

N/A Address Expiration Date NIA

4.

Identification of System: STEAM GENERATOR BLOWDOWN (LINE # 2BD3-220SN-1)

5.

(a) Applicable Construction Code ASME III Edition 1974 Addenda Winter 1976 Code Case N/A (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements:

1989 Addenda NIA

6.

Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board Identification:

Built Replaced Code No.

Or Stamped Replacement Yes/No PIPE 3" VALLOUREC &

N/A N/A HT # 344533 UNK.

REPLACEMENT NO MANNESMANN SA 335 GR P22 TUBES 3" ELBOW 90 TAILOR FORGE N/A N/A HT# LWKQ-1 UNK.

REPLACEMENT NO DEGREE STAINLESS LWKQ-2 SA 234 WP22 SMLS.

7.

Description of Work.Stem G n.tonr Rlnwrlown line # 2R1-3-920SN-1 was partially remnved and then reinstalled/modified

8.

Tests Conducted:

Hydrostatic [I Pneumatic El Nominal Operating Pressure M Other El Pressure_

psi Test Temp. IF NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 % in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12/82)

R/R# 01-02-207 ASME XI, CLASS 2 Sheet 2 of 3

0 D

re rno lnn t "r

A.,rl D

sf, r Cnf-.#-e Applicable Manufacturer's Data Reports to be attached VT-2 performed per requirements of Code Case N-416-1.

Form NIS-2 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the repair or replacement ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed Equipment Performance Supervisor Date

,20 ner or byner, sigr ee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Nnrth Carnlina and employed by Hartford Steam Boiler Insoection and Insurance Company of One State Street.

Hartford, Connecticut 06102 have inspected the components described in this Owner's Report during the period 05-13-00 to 12-14-01

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NQ144A4NIlAS Inspector's Signature National Board, State, Province, and Endorsements Date,d

__20_-

R/R# 01-02-207 ASME XI, CLASS 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet Sheet 3

of 3 Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board No.

Identification:

Built Replaced Code Or Stamped Replacement Yes/No 3" ELBOW 45 TAILOR FORGE N/A N/A HT# LWKQ-2 UNK.

REPLACEMENT NO DEGREE STAINLESS SA 234 WP22 SMLS.

3" X /" SW WFI N/A N/A HT# 697ZNC UNK.

REPLACEMENT NO PIPET SA-182 GR.F22 4" x 3" RED TAILOR FORGE N/A N/A HT# LVNU-1 UNK.

REPLACEMENT NO STAINLESS SA 234 WP22 SMLS.

4" 90 DEGREE TUBE N/A N/A HT# 676L UNK.

REPLACEMENT NO ELBOW FORGINGS OF SA-234 GR AMERICA WPB 2" PIPE GULF N/A N/A HT#7526379 UNK REPLACEME NO STATES TUBE SA-335 NT GR.P22 3" X 2" TAILOR FORGE N/A N/A HT# LWKQ-2 UNK.

REPLACEMENT NO REDUCER STAINLESS SA234WP22 SMLS.

R/R# 01-02-208 ASME XI, CLASS 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions for the ASME Code Section XI

1.

Owner.

Carolina Power & Light Name P.O. Box 1551, Raleigh, N.C. 27602-1551 Address

2.

Plant:

Shearon Harris Nuclear Power Plant Name PO Box 16-5 New Hill N r 27562-nl 1' Date:

12/24/01 Sheet 1 of 2

Unit 1 Address Repair Organization P.O. No., Job No., etc

3.

Work Performed by:

Becon Construction Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. Box 9, New Hill, N.C. 27562 Address Expiration Date N/A

4.

Identification of System: STEAM GENERATOR BLOWDOWN (LINE # 2BD4-10SN-1)

5.

(a) Applicable Construction Code ASME III Edition 1974 Addenda Winter 1976 Code Case N/A (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements:

1989 Addenda N/A

6.

Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board Identification:

Built Replaced Code No.

Or Stamped Replacement Yes/No PIPE 4" US STEEL N/A N/A HT# B86365 UNK.

REPLACEMENT NO GROUP SA 106 GR. B 4" X 2" BW LADISH N/A N/A HT# JL6SH1 UNK.

REPLACEMENT NO REDUCER

7.

Description of Work Steamm reinstalled/modified hn,

  • 2IflA1 A'.KL1

,

8.

Tests Conducted:

Hydrostatic El Pneumatic E]

Nominal Operating Pressure Z Other El Pressure__ psi Test Temp. *F NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 11/2 in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12/82) k'Rnp-ralor was ma a

  • mwuxe an i en P1 14 1;

4f')DnA 4f)QK1

R/R# 01-02-208 ASME XI, CLASS 2 Form NIS-2 Sheet 2 of 2

9.

Remarks Reference line 6 for code data reports.

Applicable Manufacturer's Data Reports to be attached VT-2 performed per requirements of Code Case N-416-1 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the repair or replacement ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authoridatio No.

NIA Expiration Date NlA Signed

,Equipment Performance Supervisor Date

/I/L ner or 0ývnelr esig ee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North rnrnlina and employed by Hartford Steam Boiler Inspection and Insurance Comoany of One State Street.

Hartford. Connecticut 06102 have inspected the components described in this Owner's Report during the period 05-13-00 to 12-14-01

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, conceming the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NC 1444NIAR Inspector's Signature National Board, State, Province, and Endorsements Date*

20 f

R/R# 01-02-209 ASME Xl, CLASS 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions for the ASME Code Section XI

1.

Owner:

Carolina Power & Light Date:

12/24101 Name P.O. Box 1551, Raleigh, N.C. 27602-1551 Sheet 1 of 2

Address

2.

Plant:

Shearon Harris Nuclear Power Plant Unit 1 Name P.O-Box 165. New Hill NC. 27562-0165 9363FR Address Repair Organization P.O. No., Job No., etc

3.

Work Performed by:

Becon Construction Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. Box 9, New Hill, N.C. 27562 Address Expiration Date N/A

4.

Identification of System: STEAM GENERATOR BLOWDOWN (LINE # 2BD4-1ISN-1)

5.

(a) Applicable Construction Code ASME III Edition 1974 Addenda Winter 1976 Code Case N/A (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements:

1989 Addenda N/A

6.

Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board Identification:

Built Replaced Code No.

Or Stamped

_Replacement Yes/No VALVE 4" BORG WARNER 58784 or N/A 435JAB2-006 1980 REPLACED YES GATE 900#

69697 or 1981 69698 SA 105 1981 36-3X1 3000#

WFI N/A NIA HT# 468 UNK.

REPLACED NO SW PIPET SA 105

7.

Description of Work Steam G enpemtor Rlowdown line

  • 2R#-4-1 1,N-1 was pn*rtially removed and then reinstalled/modified
8.

Tests Conducted:

Hydrostatic El Pneumatic El Nominal Operating Pressure 0 Other El Pressure __

psi Test Temp..F NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 '/1/2 in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12/82)

R/R# 01-02-209 ASME Xl, CLASS 2 Form NIS-2 Sheet 2 of 2

9.

Remarks Reference line 6 for code data reports.

Applicable Manufacturer's Data Reports to be attached VT-2 performed per requirements of Code Case N-416-1 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this R*P*ACEMENT conforms to the rules of the repair or replacement ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authoriat' n No.

N/A Expiration Date N/A Signed I Equipment Performance Supervisor Date it/

,20

  • )2.

Z n e 6-r Ow r s"

" De signee, Titlef CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of One State Street.

Hartford, Connecticut 06102 have inspected the components described in this Owner's Report during the period 05-13-00 to 12-14-01

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.min N.

4ANIAR Inspectors Signature National Board, State, Province, and Endorsements Date 20 z-

800K#O0 G1O FORM NPVJ.1 N CEFMIRCATE HOLDERS DATA REPORT FOR NUCLEAR PUMPS OR VALVES An RqWir'ad by the Provisions of the ASME Cade. Section 111. Div. I

1. Manufamtred by 3=LIA2r Valve Div..EorgwIarmn-r, 7500 Tyrotta Ava.,

W at Nays, calif.

(N-ame ana Aaaressato N certificate Holder)

Z. manufactured f 0,Washinrtan Public Power Suunlv System. 1Richland.- Washin~tOn 99352 4Nhem. nd Adareasoftuf"wCnWa' rwner Waahingtorl Public Power Supply

3. Location ofinstallation System.- Near IA4TSOP._ Southeastern Grals Harbor CouNt._. Washingtoni (Name Arid Aadr"M)
4. Pump or valt" arp_ Valvp Ia) Model No-.

Series No.

or Tywe (b) H Certificate Holder's Serial No0.

Nominal Inlet Sine 4

Outlet Size_______

1c)

Canadian Regisetration No.

IdI Draw-oing No.

(f) Natl.

W. CIaS" Bd. No.

1g) Year Built 900#k 69697 & 69698 N/A 435JAB2-006 2

N/A 1981 (2)

(4)

(Si

&VXAOdXf=dtohnl lre sj hJI

~XdS tm aa (61 wlA-br P--afae4=Z~~

AWM fow00m~ fSrm o hcV~m Mr (a)

Xte Md&I Sa~~

2000 475

6. Design Conditions 2160 Psi 100 Tor Valte Pressure Class N/A
7. Cold Working Pressure

.2 160..

-psiat i0OaF.

&Pressure Retaining Pieces Mart No.

Matena~l Saew. No.

Manufacturet Remarks fal Castings l

Gate-Code IT27 SA 351. CF84 Vulcan Steer (bi Forgings Body-Code 4J09 SA 105 Jorgensen Steel Bonnet-Code 4F47 SA 105 Conmton Forge IR2 5

Neck-Code 4A29 SA 105 Shultz Steel_________

Weld Cap-Code IX70 SA 105 Compton Forge_________

Retainer-Code 2P03 SA 105 Jorgensen Steel 4H081 I Comvton Forge I

I ____________________

(I)I For manually operaitd valves only.

Supplamental sheets in form of hats.

sketcnes or drawings may be used ýprovided (1) asi is $-I t2 x Ir 1. 21 information in itemsa 1, 2 and 5oan itti Oats Report is included an each sheet, and (Z1 each fy,,K e9Nbared adnumber ofjboam isncre tto attlsformf v 1hV

~ -g 9

(lam)

Thise fom M000=

maw be obtained frarn the Order Oept.

47t JB

i.

N.Y. 100 I/

S.

'I, V

m.-Ai N

I Ii

'Ii

'III lii 11!

itI I

I I

I I I

I

.1 p

/

Ii ii ii

{od i.-ied FOM NPV-1 N CERTIFICATE HOLDERV DATA REPORT FOR NUCLEAR PuMPSm OR VALVES*

F0v-FrM.

As Required by th~e Provisons of dt SECd.,Scin I.Dv

1. Manufactured by~ l.clair val've Div. S3org Warne~r, 7500 Tyram~e-Ava.,

Van Mars, caji.:f 2-Manufactured torWashInL-tan Public Power Sutrmlv SySt tN&neandi.' Addrm of rv~ro*4-or

3. L.ocationi of Instadatjon System, Near SATSOP,.

A.L Pump or Valve (a) Model No.. (b) N C~ertificate Holder's Icl Canadian Series No.

Serial Registration or Type No.

NO.

(1)

(2)

(3)

(41 (5)

(6)

(7)

(81 ThAL valvs &=~ daesigziad to bzmdAla a fl~uid meia vwhich izzltz1,Aa Staw., Wata~r

.A..,* Mo#-"

~

4"t-vby Pr-aannrc{AtIR wiith x WR Anrt Tt9 (raiet o~f owIm 1850 4 5

6. Design Conditions 2160 1

(

P~swumuti (T

L-rr~

7. Cold Working Pressure 91s0 A 0'-/V)

IL Pressure Retaining Pice Mak14.Mtet pc o-Mnfcue Ma~t~ M pc N.Miict7tRmae 4

4.
4.

Wakesha Frdv./ V*lcari Steel 54 351 CFBM D~esign conailtions werE 2000 psi 475 2160 100

___________________________-J

4.

4.

n-ly.-Crv 4A59 SA 105 T

  • 1' Jorer.se

Steel 4

1' 4.

.nn t

w --

I t Nac1-:--Code 4A29 I

SA 105 ShlzSteel_________

-Wld Ca-Coje -:X7C SA 10 I o-ene Steel Ret? iner-Code 3An9 I

SA 105 Jorzeflsefl Steel

A 1(

4.

4 Jorensen Steel SuO00m'ec'tal Shasta in form of lisMs skAtdhes or dnrw'ings may be used 4prinded V1 ISAISM M-x1 11 CZ im i

in tarnn 1. 2 and S on this 04ata Report is incduded 04% each sheet and (3) eac~ he i ~

and. j r IYE~mt 30c>

is recorded at too of t~t forrm (1/7)This jog., (E00a0271 1-1 (a) ciastings

- - 4-B IU4 3~ H32 (b I Forgings (10jr77)

SA 351 r-mm Wwakesha Frdv./

V*lcan Steel Jorzer--sen Steel

Me* Ma.

So" W Goidmo MIA (d) 0ow POW Dwm Pime-Code SA Gm B Ze 4ABI 2200 wV-1 meow MUMATE CW =MPUAMM wt owtft vw WWWAMvbovto-em ft-mo dad thathle gum& or volvei QWWWI MOW-owkwol 4

1ý vommwuodoo of M* ASM Cod4o to-fta~

P*-mW'FI&M C4m4p*nwvl&- Socie" IL CW.

1-9,74 Addwutl Cockp C.ý f4m _

N/A cow Cur AIPA4 C&nWMmw4fAm&."WdGR #ft if 1012-TISI.

CATWW OF DISIG*

gm tnftmwdm an ow of son !tam 73CO TZEMI Avg.,

Tsm NKTW. Ca. 9140 Sugm &"ova$ reowtoom I avvi oft OW 44 0~

qwdftgdamawwbft w (1)

AlwAx C.

Gbou ptowft Week.

1661%

="a maymis mufad br. il I Sbow P46W CMTTMCAIIý Cw SOW. Woracrim ow UfAeraGA64 hawing & Von* Sonwedomi4m ;OVA" by ttm Modwed gowt of S*Uw aid Pnmmim Ve=W Insomme Anti OW SWW4W PrOWWAV 40 ULUMSA&

a" a tpl"ed by LomboxwzO 4 ftawl t r of.

T-ema r.=mo, nu&pi&-

ftoo. -

W*

ow"m gr vWw% 4*wibwO im Wm 0*0 P*o*M an wu=W fts oumm ar '".

in ammtaws wiM UWASMIE CW& SmWW OL By ft*i We owdftmm wMem to W"womr mr We mi 96"m mahm ww vowrmw. ww==W or In c===.*

as OW*Wwm dome"" I* a" cow howw"wr% "

be am ý me= mr We wnokrmw vkM bw %*We !A a" "W~ for ww Woo" or ommnw dwý of a Sý of mw d" Ad" eft" or deftmame imam V" wwooc"%

Is Mom SA. Saft PFRM am Mai MRR YVA

-.'GE

R/R# 01-02-210 ASME X1, CLASS 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions for the ASME Code Section XI

1.

Owner:

Carolina Power & Light Name P.O. Box 1551, Raleigh, N.C. 27602-1551 Address

2.

Plant:

Shearon Harris Nuclear Power Plant Name P.O. Box 165. New Hill-NC. 27562-0165 Date:

12/24/01 Sheet 1

of 3

Unit. 1 Address Repair Organization P.O. No., Job No., etc

3.

Work Performed by:

Becon Construction Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. Box 9, New Hill, N.C. 27562 Address Expiration Date N/A

4.

Identification of System: STEAM GENERATOR BLOWDOWN (LINE # 2BD2-66SN-1)

5.

(a) Applicable Construction Code ASME III Edition 1974 Addenda Winter 1976 (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements:

1989

6.

Identification of Components Repaired or Replaced and Replacement Components Code Case N/A Addenda N/A Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board Identification:

Built Replaced Code No.

Or Stamped Replacement Yes/No PIPE 2""

GULF STATES N/A N/A HT # 710144 UNK.

REPLACEMENT NO VISION METALS SA 106 GR B 2" SW BONNEY FORGE N/A N/A HT# 9182 UNK.

REPLACEMENT NO COUPLING SA 105

7.

Description of Work ste.am Gepnerator Rlowdown line # 2RI-2-61R3SN-1 was partially removed and then reinstalled/modified

8.

Tests Conducted:

Hydrostatic El Pneumatic Dl Nominal Operating Pressure E Other El Pressure

.psi Test Temp. 'F NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/ in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12/82)

R/R# 01-02-210 ASME XI, CLASS 2 Form NIS-2 Sheet 2 of 3

9.

Remarks Reference line 6 for code data reports.

Applicable Manufacturer's Data Reports to be attached VT-2 performed per requirements of Code Case N-416-1 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPI ACFMINT conforms to the rules of the repair or replacement ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorizatio

o.

N/A Expiration Date N/A Signed Y

1-I

W*/',

Equipment Performance Supervisor Date

, 20 _

Z_

' ner or b"wner' 6si nee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North rwrnlina and employed by Hartford Steam Boiler Inspection and Insurance Company of One State Street.

Hartford, Connecticut 06102 have inspected the components described in this Owner's Report during the period 05-13-00 to 12-14-01

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspectin Commissions NC 1444NIA2 "National Board, State, Province, and Endorsements Date

-J' 20O'--

R/R# 01-02-210 ASME XI, CLASS 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet Sheet 3

of 3 Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board No.

Identification:

Built Replaced Code Or Stamped Replacement Yes/No 2" X 2" X 3" BONNEY N/A N/A HT# 75509 UNK.

REPLACEMENT NO RED. TEE

-FORGE SA 105 4" X 2" LADISH CO.

N/A N/A HT# JL6SH1 UNK.

REPLACEMENT NO REDUCER SA 234 WPB

R/R# 01-02-211 ASME XI, CLASS 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions for the ASME Code Section XI

1.

Owner:

Carolina Power & Light Name P.O. Box 1551, Raleigh, N.C. 27602-1551 Address

2.

Plant:

Shearon Harris Nuclear Power Plant Name P.O. Box 165. New Hill. NC. 27562-0165 Date:

12/24/01 Sheet 1

of 3

Unit 1 231R68 Address Repair Organization P.O. No., Job No., etc

3.

Work Performed by:

Becon Construction Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. Box 9, New Hill, N.C. 27562A Address Expiration Date N/A

4.

Identification of System: STEAM GENERATOR BLOWDOWN (LINE # 2BD3-219SN-1)

5.

(a) Applicable Construction Code ASME III Edition 1974 Addenda Winter 1976 Code Case N/A (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements:

1989 Addenda N/A

6.

Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board Identification:

Built Replaced Code No.

Or Stamped Replacement Yes/No PIPE 3" VALLOUREC &

N/A N/A HT # 344533 UNK.

REPLACEMENT NO MANNESMANN SA 335 GR P22 TUBES 3" ELBOW 90 TAILOR FORGE N/A N/A HT# LWKQ-1 UNK.

REPLACEMENT NO DEGREE STAINLESS LWKQ-2 SA 234 WP22 SMLS.

7.

Description of Work Rteim Cnerntnr Rlowdnwn line # 2Rf-3-219SN-1 w.

.nrti~llv removed ind then reinstalled/modified

8.

Tests Conducted:

Hydrostatic El Pneumatic El Nominal Operating Pressure E Other El Pressure__ psi Test Temp. °F NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12/82)

RIR# 01-02-211 ASME XI, CLASS 2 Form NIS-2 Sheet 2 of 3

9.

Remarks Reference line 6 for code data reports.

Applicable Manufacturer's Data Reports to be attached VT-2 performed per requirements of Code Case N-416-1.

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the repair or replacement ASME Code,Section XI.

Type Code Symbol Stamp NIA Certificate of Authoplzat n No.

N/A Expiration Date N/A Signed f

Equipment Performance Supervisor Date I/

, 20. 1 2 P

river 0*o wn l DesYgnee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North CrCrolina and employed by Hartford Steam Boiler Inspection and Insurance Company of One State Street, Hartford, Connecticut 06102 have inspected the components described in this Owner's Report during the period 05-13-00 to 12-14-01

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NC 1444NIAB Inspector's Signature National Board, State, Province, and Endorsements

Date, 20°0-

R/R# 01-02-211 ASME Xl, CLASS 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet Sheet 3 of 3 Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board No.

Identification:

Built Replaced Code Or Stamped Replacement Yes/No 3" ELBOW 45 TAILOR FORGE N/A N/A HT# LWKQ-2 UNK.

REPLACEMENT NO DEGREE STAINLESS SA 234 WP22 SMLS.

3" X 3/4" SW WFI N/A N/A HT# 697ZNC UNK.

REPLACEMENT NO PIPET SA-182 GR.F22 4" x 3" RED TAILOR FORGE N/A N/A HT# LVNU-1 UNK.

REPLACEMENT NO STAINLESS SA 234 WP22 SMLS.

4" 90 DEGREE TUBE N/A N/A HT# 676L UNK.

REPLACEMENT NO ELBOW FORGINGS OF SA-234 GR AMERICA WPB 2" PIPE GULF N/A N/A HT#7526379 UNK REPLACEMENT NO STATES TUBE SA-335 GR.P22 3" X 2" TAILOR FORGE N/A N/A HT# LWKQ-2 UNK.

REPLACEMENT NO REDUCER STAINLESS SA 234 WP22 SMLS.

R/R# 01-02-212 ASME Xl, CLASS 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions for the ASME Code Section XI

1.

Owner:

Carolina Power & Light Name P.O. Box 1551, Raleigh, N.C. 27602-1551 Address

2.

Plant:

Shearon Harris Nuclear Power Plant Name P.O. Box 165. New Hill. N.C. 27562-0165 Date:

12/24101 Sheet 1

of IUnit 1 3

Address Repair Organization P.O. No., Job No., etc

3.

Work Performed by:

Becon Construction Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. Box 9. New Hill, N.C. 27562 Address Expiration Date N/A

4.

Identification of System: STEAM GENERATOR BLOWDOWN (LINE # 2BD4-65SN-1)

5.

(a) Applicable Construction Code ASME III Edition 1974 Addenda Winter 1976 Code Case N/A (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements: 1989 Addenda NIA

6.

Identification of Components Repaired or Replaced and Replacement Components

7.

Description of Work 5<t~m (_n.r~tor Rlow-own lin_ i 9Rfl4-RSN-I w.

.nrti~lly rnmov~d Rnthen reinstalled/modified

8.

Tests Conducted:

Hydrostatic 0 Pneumatic D Nominal Operating Pressure [

Other E' Pressure __ psi Test Temp. °F NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 /2 in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12/82)

Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board Identification:

Built Replaced Code No.

Or Stamped Replacement Yes/No PIPE 4" US STEEL N/A N/A HT# B86365 UNK.

REPLACEMENT NO GROUP SA 106 GR. B Unit 1

Form NIS-2

eII

a tC III,c '.1 H.* 

.JOtO Applicable Manufacturers Data Reports to be attached VT-2 performed per requirements of Code Case N-416-1.

R/R# 01-02-212 ASME Xl, CLASS 2 Sheet 2 of 3

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPI ACFMFNT conforms to the rules of the repair or replacement ASME Code, Section Xl.

Type Code Symbol Stamp

/IA Certificate of Authorization No.

NIA Expiration Date NWA Signed i

W-4 Equipment Performance Supervisor Date I/f=I

,2007.

Sine -- '-Yner or n*'e~ sig~ee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Nnrth (arlina and employed by Hartford Steam Boiler Inspection and Insurance Company of One State Street, Hartford. Connecticut 06102 have inspected the components described in this Owner's Report during the period 05-13-00 to 12-14-01

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NC. 1444NIAR

---tnspector's Signature National Board, State, Province, and Endorsements Date 2 0 c?--

I il.

RemamS

R/R# 01-02-212 ASME X1, CLASS 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet Sheet 3 -of 3 Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board No.

Identification:

Built Replaced Code Or Stamped Replacement Yes/No 2" X 2" X W" BONNEY N/A N/A HT# 75509 UNK.

REPLACEMENT NO RED. TEE FORGE SA 105 4" X 2" LADISH CO.

N/A N/A HT# JL6SH1 UNK.

REPLACEMENT NO REDUCER SA 234 WPB

RIR# 01-02-213 ASME Xl, CLASS 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions for the ASME Code Section XI

1.

Owner:

Carolina Power & Light Name P.O. Box 1551, Raleigh, N.C. 27602-1551 Address

2.

Plant Shearon Harris Nuclear Power Plant Name P.O. Box 165. New Hill-N.C. 27562-0165 Address

3.

Work Performed by:

Becon Construction Name P.O. Box 9. New Hill. N.C. 27562

4.

5.

6.

Date:

12/24/01 Sheet 1

of 2

u nit 1 Repair Organization P.O. No., Job No., etc Type Code Symbol Stamp NIA Au~thorization No_

N/A Address Expiration Date N/A Identification of System: STEAM GENERATOR BLOWDOWN (LINE # 2BD4-7SN-1)

(a) Applicable Construction Code ASME III Edition 1974 Addenda Winter 1976 Code Case N/A (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements: 1989 Addenda N/A Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board Identification:

Built Replaced Code No.

Or Stamped Replacement Yes/No VALVE 4" BORG WARNER 58754 or N/A 435JAB2-006 1980 REPLACEMENT YES GATE 900#

69697 or 1981 69698 SA 105 1981

7.

Description ofWork t C.pfmtnr Rlowdown linmp f 9Rr)4-7SN-1 wa-; mndifite-d with thp in.itallation of q niw gate valve

8.

Tests Conducted:

Hydrostatic El Pneumatic 0l Nominal Operating Pressure 0 Other Dl Pressure__ psi Test Temp. OF NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 % in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12/82)

Authorization No N

P.O.

Bo lfN.C....

R/R# 01-02-213 ASME X1, CLASS 2 Form NIS-2 Sheet 2 of 2

9.

Remarks Reference line 6 for code data reports.

Applicable Manufacturer's Data Reports to be attached VT-2 performed per requirements of Code Case N-416-1 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this RFPI AGFMENT onforms to the rules of the repair or replacement ASME Code, Section Xl.

Type Code Symbol Stamp MIA Certificate of Authonzation5o.

N/A Expiration Date NWA Signed q" quipment Performance Supervisor Date

/

,20 f

e*'*r o-r i ve r'V,;es [*ee, T itle CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North -Crolina and employed by Hartford Steam Boiler Insoection and Insurance Comoany of One State Street.

Hartford, Connecticut 06102 have inspected the components described in this Owner's Report during the period 05-13-00 to 12-14-01

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

O

__Commissions NC 1444NIAB Inspector's Signature National Board, State, Province, and Endorsements Date ---- f---'

20

BOOK# 0 G10 0 FORM NFV-1 N CERTICATE HOLDERX DATA REPORT FOR NUCLEAR PUMPS OR VALVES*

Ae Required by the Provisions of the ASME Cod*. Section Ill, Div.y 1

1 Manufactured bwlv ueIaar Va1-fDiy. 3orn WArnar, 7500 TyjaIS Ava., Van Naya, Calif.

(Name and Address of N cartificate Haoadri

2. Manufactured forWashiny-tcfl PUblic Power SuR121y System-Richlazd Was hinrton 99352 4Nan Ma anddrumg of Purcfieew or Owneri Waghinton Public Power SPPl I Location of installation Systezm Near SATSOP, Souteaster Gra HaborCon WaSh z to~n Ihame amd AodrdsI A. pump of Valve frarp V 1IVP

. Nominal (a) Model N&c. (b), N Cortificate Hoider's (c) Canadian swime No.

Serial Registration or Typo No.

No.

69697 & 69698 NIA Inle Size 4______

Outlet Size 4_____

(inch) l(anln Id) Drawving No.

Ili Nat').

to) Year Ma Cleass 8d. No.

Built 435JAB2-006 2 N/A 1981 Tha valves ame dasignd to lbanla a fluid linda vhicbh iZlLdS st~ats, vatar

~.iuAanu er 1nAfed Mtr.. P-te -

affageisa

-.2t I=

Tha~

Ifief dacnotiofl pt sefti, kwr WhidIh 1.

4pqpn teaeratn vreasse racinx ox the-:ssia Jta.

2000 475

6. Desgn Conditions 2160 Ps 100
  • F or Valve Pressure Clams N/A (F;ZW;(TwmOeretawgi
7. Cold Working Premu~rv psi at 100T.

IL Pressure Retaining P1ecr Mark No.

Material Spec. No.

Manufacturerm Gate-Code LT27 SA 351 CF814 Vulcan Steel._________

(bE Forging.

,,'Rd g-Code Q309 SA 1.05 Joraensen Steel SA 10- 5 -oene Steel

-~

i Comotan Forae SA 1.05

-S-105-

-opo o

lR2 5

k-Code 4A29 IS 15IShultz Steel SA 1.05 SA 1.05 Comoton Forae SA 105-

-otno Fa Jorgensen Steel t

I Co lton Forxe Weld Cap-Code-1170

,Retainer-Code 2P03 4H108 I

I I ________________

ill For manually operated Waive. ontf.

Suomental shemt in formi of Geats, o~.sches or draw-ings may be used provided (I) s ýie s 8-tir at 117 (2) information in ite-m 1. 2 and 5 on this Data Report is included on eachi sheet. and (3) ecah' (~~J bered arnd number of-dwmbet is recorded at Mop at dii font's L~e-o 04Z9 3

(lam)

'ini bm i 6000571 may tw a&-11We f-u the Ondu 471hIQN N.Y. 10 900#

(2)

(31 (4)

(71 (9)

(101 S.

.-2 --- etg-Codri 4F*47

.- Ne~

WRshInaton 99352 900#

1981

PO Lw"Jr~

OL MwSJ4.

~MwnWt

$wc.

No.Raad Draia.Z&B=eCode 3i891 SA 106 GR B

ý4Ubtl Tube

.. ~o~

i~vawi~-

.2200 G11RCATE I COM aLIAIct We mdfy J thm o

otaftw'im o we in Mis.we~

Mersa saed aim V"M pm6 or woe miowmw 0 Mwe "A"ON

    • t~wycwn0 co me ASME C&M fartaw mo Pawns Plonw Canxxnomm& 3acun M. ti.. 1 1

AdouaViziter

'76 CoeCw#&-/

f%

31, Nuelmr Vaiwe Div..BOTZ wma~r Ow ASME Cedflcms 0 AadioimdbiMo NO LM--

to. um.. ow o P oni Inr~o an fM Y

ofC Do=u Vazar ftQTv~Aw Y

x CA.

914Ot 6Vaaium ailoan e (Cjama I ontol 444e

/ A lealm cp~ao,~

buea y II Alwin C. Cl~n Fr gl-Wah.

PAW"&

F1A sm

-uyw ON~e by 411 (1) SgnUe uwed.U nal"AO Lew A&M*PO

~TCgRATE OF SNOP MMWMM~fO L lh* unt~d"Wn.ho"~d 6~Ii 0 We mp too"~e laved by am. M~ade goos d34f M W Sa Puir Vowe IlpiM of T;Vm amm a

wo te

puam, or vow.

6"uibih dii m Rue port on spumW Oft puxqLp or vokwe in assmEemnin ws meA AMM Coa.L 3Sean IlL By d"" tis omewasom.

amome umO ia fvurm arnaempo memo owy %swoNov agvnmpld fo onmming-w dow saqulpoini dommobud in Ok OeM Roomt Pw~diwmwnw nehdis' On Imp1a so ON't enpsy OR4heN9W be gdebis aySO ffwPuw fo m ay Pooem iU~vi' of ploo" 4enm" of *e isms ot euny knd arisig 6"r 4W ieminmd AIA V"i Iinsmci.

MRR

Mod if ied

\\V-P1-For=.

FORM NpV-I N CE"lFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS Oft VAILs' A& Required by the Provisions of the ASME Cod.. Section fit. Div. I

'ee rema- --r

  • .,Au.qgr.a4 Ii., 1w=1A~ar Va lve Div. &Mor Warner, --7500 Tyr ia Aw., Van~ UNys Calif.

(Name and Address of N Certificate Holder)

2. Manufactured fo~sintr Public Power Supmly' System.. Richland, Wa hr=nMton 99352 VNam. and Adarus ofPuracwr or Owner) Washingt on Public Power supply.

Loato of intalao System. Near -RATSOP, Southeastern C

y.

A. Pump or Valve (a) model No..

Serie* No.

or Type lsd45' ond More Gate Valve (b) N Certificate Holder's Serial NO.

Idl C Reg Nominal Inlet Site4

anadian M7 istration (d) Drwp
01) Narl.

gqi Year No.

No.

BN.

Built RR79-1 98764 X/A 435JAE2--006 2

NA 18 Th~a V&aiwS AMz dAsigned to 'handle & fI-4ind& iaWhiIgh JIyzAla steas, Tatar

~ent~ h~tM waer-Artc-. asocIA,!ad iwithAWt 1and E.T tenparattrre

~

u~pressuza rac~gofi state CI.OW.

185045

&Oesign Conditions 2160 psi I

-/

(10

7. Cold Working Pressure 91 psi at IOTF.

/VI 8.Presgsure Retaining T 7o2o M*C* Noc.

Material Spec. No.

ManufacturerRoret fat castings

______________I_____________________

G.ate-Code 113433 2

.33 SA 351 CFSM Wmikesha Frdy./ V*lcan Steel a

L51gn CODU1TLfl1



_ I2000 psi 47-5 216 0

_________________________0 thbI Forgings

4.

4.

A I-1

A A O

A 1fl

.Tnrmensern Stne-ol d 4A59 105 4

1 SA 10F, Jorr-ensexn Steel onrie o

-%3 h

¶ f'J AAfIO ci 1fl

ecp.-Code SA 105 Shultz Steel 2

-N-

-'Ve in r

C d

I9 SA 105

.Jrn-'ensen Steel Ijorrensefi Steel

~.(1) For nieE'kiy opeet~ded iws only.

M f

SupookeTnntat sheens in form' of [isma sketches or dawrings may be used provided (Ii 4LSP1Xar.

as kformadnpn in itenw 1. 2 and S on t~w Dana Report is included 0"s eachi sheet. and (3) each~ she n

Y1f t

0l is recorded at top of giis fonT'.U (10177)This form (9000E371 C)Afl.

(Z)

(3' (61 (71 (10f771 S)00,g "K7C' Jorrensen Steel

-C d e lc! Qp o

Design cond!

ns wer Sod n

mallwid So" NIL ids cow ft'*

Pizo-Cods Aml IL if me aL vom wv-l glow*

AW CM619CATE Cr caimuAtow wt o"OfIf rm vw MWIWIP, to.

,jgdidpoy, -

1-974 a* of 9W. AAkW COW P mW M&W C4oWnwftý Sooien IL Div. L calp cmw f, cow V

stow ytielsav Valve b*17ý134!1 va=ar Ow ASMI CwMwft of AMP.Modait ha CM I NWATKW. OF ONSIG*

Co.

9,140 swomwWovais -own ICU*& I arao ame*m W/A OWW vq@dftCxdGMCWdftd W (11 AIWAM C, ChOu PE&M Wash.

leats SbVft wwmyuiLcwofl" br-fl)

VA ftstow AM III&

cmyfvqc#*Tlý cw SHOW. *404MINM 7_

swiftow4w p OWUM w mvtpkp"d of cammiat r r-kmrs I =Ila aw owam or w0wo. dowpillood In wao Ova fteawr o"

mmd a" pump. ar In ao=fdmMn VAM UWASM COft SeedW dL By loo, 0 WAS owdoow% no~

we mm"Gw fmr We "llaimm mobw &W VVWTU"W&

0 1 or b;oio.L cm am aw OOLOWNM degava" 10 We cow PuMPAnTWW% Asilftel On blowmW MW We an"Mw4ve ~

be-GoOde i'm SMY mamw Im ww WwwW &,"m or ampum I or 0 km of aw d" &A" tram w Gonamcme vom mm wagoo"amm Imam ad. 311MIL PPRM am Nei MRR YVA_

R/R# 01-02-214 ASME X1, CLASS 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions for the ASME Code Section XI

1.

Owner:

Carolina Power & Light Name P.O. Box 1551, Raleigh, N.C. 27602-1551

2.

Plant Address Shearon Harris Nuclear Power Plant Name P.O Box 165. New Hill. NC. 27562-0165 Date:

12124101 Sheet 1

of 2

I nit I Address Repair Organization P.O. No., Job No., etc

3.

Work Performed by:

Becon Construction Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. Box 9, New Hill, N.C. 27562 Address Expiration Date N/A

4.

Identification of System: STEAM GENERATOR BLOWDOWN (LINE # 2BD4-6SN-1)

5.

(a) Applicable Construction Code ASME III Edition 1974 Addenda Winter 1976 Code Case N/A (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements:

1989 Addenda NIA

6.

Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board Identification:

Built Replaced Code No.

Or Stamped Replacement Yes/No PIPE 4" US STEEL N/A N/A HT # B86365 UNK.

REPLACEMENT NO GROUP SA 106 GR B

7.

Description of Work Stearm ('_nt-tnr Rlowdown linep It 2RI4-65SN-1 was partially remnved ind the~n reinstalled/modified

8.

Tests Conducted:

Hydrostatic Li Pneumatic 0 Nominal Operating Pressure 10 Other D Pressure psi Test Temp. OF NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12/82)

Unit I

R/R# 01-02-214 ASME Xl, CLASS 2 Form NIS-2 Sheet 2 of 2

9.

Remarks Reference line 6 for code data reports.

Applicable Manufacturer's Data Reports to be attached VT-2 performed per requirements of Code Case N-416-1 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this RFPI ACFMFNT conforms to the rules of the repair or replacement ASME Code, Section Xl.

Type Code Symbol Stamp WIJA Certificate of AuthorizationU.

N/A Expiration Date N/A Signed quipment Performance Supervisor Date li20 0-7, O)ner or Oere'sign e, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carlina and employed by Hartford Steam Boiler Insoection and Insurance Comoanv of One State Street, Hartford-Connecticut 06102 have inspected the components described in this Owners Report during the period 05-13-00 to 12-14-01

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NC-1444NIAB I-nspector's Signature National Board, State, Province, and Endorsements Date

-' ?Z 20

R/R# 01-02-215 ASME Xl, CLASS 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions for the ASME Code Section XI

1.

Owner:

Carolina Power & Light Name P.O. Box 1551, Raleigh, N.C. 27602-1551 Address

2.

Plant:

Shearon Harris Nuclear Power Plant Name P 0 Rnx 165 New Hill NCr 27562-0165 Address

3.

Work Performed by:

Becon Construction Name P.O. Box 9. New Hill. N.C. 27562 Address Date: 12/24/01 Sheet 1 of 4

Unit 1 7.3R.3R Repair Organization P.O. No., Job No., etc Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A

4.

Identification of System: STEAM GENERATOR BLOWDOWN (SUPPORT STEEL)

5.

(a) Applicable Construction Code ASME III Edition 1974 Addenda Winter 1976 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:

1989

6.

Identification of Components Repaired or Replaced and Replacement Components Code Case N/A Addenda N/A Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board Identification:

Built Replaced Code No.

Or Stamped Replacement Yes/No ANGLE 2 X 2 X ROANOK N/A N/A HT# JB9473 UNK.

REPLACEMENT NO 1/4" ELECTRIC SA 36 PLATE,114" ROANOK N/A N/A HT# JC5987 UNK.

REPLACEMENT NO ELECTRIC SA 36 ANGLE 2 X 2 X ROANOK N/A NIA HT# JC3100 UNK.

REPLACEMENT NO 3/8" ELECTRIC SA 36 PLATE %"

ROANOK N/A N/A HT# JC6116 UNK.

REPLACEMENT NO ELECTRIC SA 36 ANGLE 3 X 3 X ROANOK N/A NIA HT# JC3349 UNK.

REPLACEMENT NO 1/4" ELECTRIC SA 36

7.

Description of Work INSTALLED NEW SUPPORTS ON BLOWDOWN SYSTEM AND MODIFIED EXISTING SUPPORTS

8.

Tests Conducted:

Hydrostatic [-

Pneumatic [l Nominal Operating Pressure [I Other El NDE Pressure __psi Test Temp.

OF NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2/2 in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12/82)

Code Case N/A

R/R# 01-02-215 ASME XI, CLASS 2 Sheet 2 of 4

Form NIS-2 a

Oa 4-&

0-farn-a 1in af

-^A A~

d+n rn+c Applicable Manufacturer's Data Reports to be attached VT-3 performed on hangers after modification/installation CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REP[ ACFMFNT conforms to the rules of the repair or replacement ASME Code,Section XI.

Type Code Symbol Stamp MIA Certificate of Authorizatio

0.

N/A Expiration Date N/A Signed E* uipment Performance Supervisor Date 1

,20 62 O-Over or'OwnefDedignee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Nnrth 'arnlinc and employed by Hartford Steam Boiler Insoection and Insurance Companv of One State Street.

Hartford. Connecticut 06102 have inspected the components described in this Owner's Report during the period 05-13-00 to 12-14-01

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Commissions NC 1444NIAR Inspector's Signature National Board, State, Province, and Endorsements Date,

20

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet Sheet 3

of 4 Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board No.

Identification:

Built Replaced Code Or Stamped Replacement Yes/No PLATE I/"

ROANOK N/A NIA HT# JC2016 UNK.

REPLACEMENT NO ELECTRIC SA 36 PLATE, 1" DUBOSE N/A N/A HT# Y08953 UNK.

REPLACEMENT NO SA 36 TUBE STEEL LEAVITT TUBE NIA N/A HT#

UNK.

REPLACEMENT NO CO.INC.

4 X 4 X 1/4 832N34280 A500 GR.B PLATE 3/4" CORUS N/A N/A HT# AOX2054 UNK.

REPLACEMENT NO SA 36 C4 X7.25 SMI STEEL N/A N/A HT#J12131 UNK.

REPLACEMENT NO SA 36 C4 X7.25 SMI STEEL N/A N/A HT#J12131 UNK.

REPLACEMENT NO SA 36 TUBE STEEL SOUTHLAND N/A N/A HT# B10847 UNK REPLACEME NO 2 X 2 X 3/16" TUBE INC.

A-500 GR B NT PLATE 1 GULF STATES N/A N/A HT# 7472446 UNK.

REPLACEMENT NO STEEL INC.

SA 36 W4 X 13 NUCORE N/A N/A HT# 1104440 UNK.

REPLACEMENT NO STEEL SA 36 W6 X 20 NUCORE NIA N/A HT# 1104104 UNK.

REPLACEMENT NO STEEL SA 36 TUBE STEEL INDEPENDEN N/A N/A HT# GF0413 UNK.

REPLACEMENT NO CE TUBE 3 X 3 X 1/4" CORP.

A 500 GR B TUBE STEEL LEAVIT TUBE N/A N/A HT#

UNK REPLACEMENT NO CO.

4 X 4 X 1/2" 833L65720 A 500 GR B PLATE 1-1/2" BONNEY N/A NIA HT#

UNK.

REPLACEMENT NO FORGE SA 36 C3 X 6 SMI STEEL N/A N/A HT# J12184 UNK.

REPLACEMENT NO SA 36

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet Sheet 4

of 4 Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board No.

Identification:

Built Replaced Code Or Stamped Replacement Yes/No PLATE 1/2" FERALLOY N/A N/A HT# 1106933 UNK.

REPLACEMENT NO CORP.

SA 36 PLATE 3/4" US STEEL N/A N/A HT# D04009 UNK.

REPLACEMENT NO GROUP SA 36 PLATE 1/2" US STEEL N/A N/A HT# E04583 UNK.

REPLACEMENT NO GROUP SA 36 TS 4 X 4 X /"

LEAVIT TUBE N/A N/A HT# 85919 UNK.

REPLACEMENT NO CO.

A 500 GR B TS 2 X 2 X1/2" LEAVIT TUBE N/A N/A HT# T86478 UNK.

REPLACEMENT NO CO.

A 500 GR B TS 4 X 4 X LEAVIT TUBE N/A N/A HT# Y05656 UNK.

REPLACEMENT NO 3/8" CO.

A 500 GR B TS 2 X 2 X1/2" LEAVIT TUBE N/A N/A HT# Y07274 UNK.

REPLACEMENT NO CO.

A 500 GR B PLATE 1-1/2" GULF N/A N/A HT# 7549350 UNK.

REPLACEMENT NO STATES STEEL SA 36

R/R# 01-02-216 ASME Xl, CLASS 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions for the ASME Code Section Xl

1.

Owner Carolina Power & Light Name P.O. Box 1551, Raleigh, N.C. 27602-1551 Address

2.

Plant:

Shearon Harris Nuclear Power Plant Name P.0 Box 165. New Hill N.C. 27562-0165 Date: 12/24/2001 Sheet 1

of 7

Unit 1

3.

Work Pe Address Repair Organization P.O. No., Job No., etc rformed by:

Becon Construction Type Code Symbol Stamp NIA Name Authorization No.

N/A P.O. Box 9, New Hill, N.C. 27562 Address Expiration Date N/A

4.

Identification of System:

STEAM GENERATOR BLOWDOWN (SUPPORT COMPONENTS)

5.

(a) Applicable Construction Code: ASME SEC III 1974 Edition N/A Addenda WINTER 76 Code Case N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989

__ Addenda N/A

6.

Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board No.

Identification:

Built Replaced Code Or Stamped Replacement YesINo Blowdown Hanger BD-H 0071 1.5 STRUT Bergen Power 2420 N/A S/N 41700 UNK Replacement N/A AAS'Y WITH MSA BY PS S/N 41699 CO. (2EA) 1.5 Bergen Power 1001 N/A Heat UNK Replacement N/A RESTRAINT END no.BPIOOIRI ATIACHMEN T

1.5 Bergen Power 1001 N/A Heat UNK Replacement N/A RESTRAINT END no.BPI001RI ATTACHMEN T

3" PIPE SIZE Bergen Power 283 N/A MRR YVR UNK Replacement N/A U-BOLT 01035 7.

Description of Work BLOWDOWN HANGERS INSTALLATION

8.

Tests Conducted:

Hydrostatic El Pneumatic El Nominal Operating Pressure El Other [I Pressure__ psi Test Temp. _

F NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12/82) 9'W.IR

R/R# 01-02-216 ASME XI, CLASS 2 Sheet 2 of 7

Form NIS-2

9.

Remarks REFERENCE LINE 6 FOR CODE DATA REPORTS Applicable Manufacturer's Data Reports to be attached VT-3 performed on hangers after modification/installation CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the repair or replacement ASME Code,Section XI.

Type Code Symbol Stamp NWA Certificate of Authorization No.

N/A Expiration Date N/A Signed quipment Performance Supervisor Date

./,/20 Signed " -ovr or O-n-er's 5tsigUee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Caromlina and employed by Hartford Steam Boiler Insoection and Insurance Company of One State Street, Hartford, Connecticut 06102 have inspected the components described in this Owner's Report during the period 05-13-00 to 12-14-01

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NC 1444NIAB

  • -"fispector's Signature National Board, State, Province, and Endorsements Date

'-_e' 2 0 0 o

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet Sheet 3

of 7

Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board No.

Identification:

Built Replaced Code Or Stamped Replacement Yes/No Blowdown Hanger BD-H 00499 1.5 PIPE Bergen Power 2600 N/A MRR YVR-UNK Replacement N/A CLAMP FOR 3"

01035 Blowdown Hanger BD-H 00506 1.5 SHORT Bergen Power 2420 N/A MRR YVR-UNK Replacement N/A STRUT ASSY.

W/MSA BY 01035 PSA 1.5 PIPE Bergen Power 6202 N/A MRR YVR-UNK Replacement N/A CLAMP 01035 Blowdown Hanger BD-H 00507 1.5 Bergen Power 2540 N/A MRR YVR-UNK Replacement N/A MECHANICAL SNUBBER 01035 1.5,3" PIPE Bergen Power 2640 N/A MRR YVR-UNK Replacement N/A CLAMP 01035 Blowdown Hanger BD-H 00510 1.5 RIDGED Bergen Power 2200 N/A MRR YVR-UNK Replacement N/A STRUT 01035 1.5 PIPE Bergen Power 2600 N/A MRR YVR-UNK Replacement N/A CLAMP FOR 2" PIPE 01035 Blowdown Hanger BD-H 00356 1.5 RIGID Bergen Power 2200 N/A MRR YVR-N/A Replacement N/A STRUT 01035 1.5 2" PIPE Bergen Power 2600 N/A MRR YVR-UNK Replacement N/A CLAMP 01035

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet Sheet 4

of 7

Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board No.

Identification:

Built Replaced Code Or Stamped Replacement Yes/No Blowdown Hanger BD-H 00357

.35 Bergen.Power 2540 N/A S/N # 41665 UNK Replacement N/A MECHANICAL SNUBBER

.35 PIPE Bergen Power 2640 N/A MRR YVR-UNK Replacement N/A CLAMP 2" 01035 Blowdown Hanger BD-H 00361 2.5 3" PIPE Bergen Power 2600 N/A MRR YVR-UNK Replacement N/A CLAMP 01035 Blowdown Hanger BD-H 00362 1.5 PIPE Bergen Power 2640 N/A MRR YVR-UNK Replacement N/A CLAMP 3" 01035 Blowdown Hanger BD-H 00363 3" PIPE Bergen Power 6101 N/A MRR YVR-LINK Replacement N/A CLAMP 01035 Blowdown Hanger BD-H 00364 1.5 PIPE Bergen Power 2640 N/A MRR YVR-LINK Replacement N/A CLAMP 3" 01035 Blowdown Hanger BD-H 00374 1.5, 1" PIPE Bergen Power 2600 N/A MRR YVR-UNK Replacement N/A CLAMP 01035 1.5 STRUT Bergen Power 2000 N/A MRR YVR-LINK Replacement N/A 01035 Blowdown Hanger BD-H 00585

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet Sheet 5

of 7

Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board No.

Identification:

Built Replaced Code Or Stamped Replacement Yes/No 3" PIPE Bergen Power 6101 N/A MRR YVR-UNK Replacement N/A CLAMP 01035 Blowdown Hanger BD-H 00589 1.5 PIPE Bergen Power 2640 N/A MRR YVR-UNK Replacement N/A CLAMP 2" 01035 1.5 STRUT Bergen Power 2420 N/A MRR YVR-UNK Replacement N/A ASSY W/MSA BY P.S. CO.

01035 Blowdown Hanger BD-H 00604 1.5 Bergen Power 2540 N/A S/N # 41697 UNK Replacement N/A MECHANICAL SNUBBER 1.5 PIPE Bergen Power 2640 N/A MRR YVR-UNK Replacement N/A CLAMP 2" 01035 Blowdown Hanger BD-H 00613 1.5 PIPE Bergen Power 2640 N/A MRR YVR-UNK Replacement N/A CLAMP 2" 01035 1.5 STRUT Bergen Power 2540 N/A MRR YVR-UNK Replacement N/A ASSY W/MSA BY P.S. CO.

01035 Blowdown Hanger BD-H 03228 2.5 STRUT Bergen Power 2100 N/A MRR YVR-UNK Replacement N/A 01035 2.5,4" PIPE Bergen Power 2600 N/A MRR YVR-UNK Replacement N/A CLAMP 01035 Blowdown Hanger BD-H 03229

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet Sheet 6

of 7

Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board No.

Identification:

Built Replaced Code Or Stamped Replacement YesINo 1.5 Bergen Power 2540 N/A MRR YVR-UNK Replacement N/A MECHANICAL SNUBBER 01035 1.5 PIPE Bergen Power 2640 N/A MRR YVR-UNK Replacement N/A CLAMP 4" 01035 Blowdown Hanger BD-H 00036 1.5 PIPE Bergen Power 2640 N/A MRR YVR-UNK Replacement N/A CLAMP 01035 1.5 Bergen Power 2540 N/A S/N 41694 UNK Replacement N/A MECHANICAL SNUBBER Blowdown Hanger BD-H 00049 1.5 Bergen Power 2540 N/A MRR YVR-UNK Replacement N/A MECHANICAL SNUBBER 01035 1.5 PIPE Bergen Power 2640 N/A MRR YVR-UNK Replacement N/A CLAMP 01035 Blowdown Hanger BD-H 00050 2.5 PIPE Bergen Power 2600 N/A MRR YVR-UNK Replacement N/A CLAMP 01035 Blowdown Hanger BD-H 00051 Bergen Power 2003 N/A MRR YVR-UNK Replacement N/A END ATTACHMEN 01035 T (TOP)

Bergen Power 2003 N/A MRR YVR-UNK Replacement N/A END ATTACHMEN 01035 T (BOTTOM)

ITEM 4 FOR Bergen Power 1001 N/A MRR YVR-UNK Replacement N/A 1.5 SNUBBER END 01035 ATTACHMEN T (TOP)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet Sheet 7

of 7

Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board No.

Identification:

Built Replaced Code Or Stamped Replacement Yes/No ITEM 4 FOR Bergen Power 1001 N/A MRR YVR-UNK Replacement N/A 1.5 SNUBBER END 01035 ATTACHMEN T (BOTTOM) 3" U-BOLT Bergen Power 6502 N/A MRR YVR-UNK Replacement N/A 01035 Blowdown Hanger BD-H 00610 1.5 Bergen Power 2540 N/A S/N 41698 UNK Replacement N/A MECHANICAL SNUBBER 1.5 PIPE Bergen Power 2640 N/A MRR YVR-UNK Replacement N/A CLAMP 3" 01035 Blowdown Hanger BD-H 00455 3" PIPE SIZE Bergen Power 6502 N/A MRR YVR-UNK Replacement N/A U-BOLT 1/2" DIA.

01035 3/4" PIPE SIZE Bergen Power 6502 N/A MRR YVR-UNK Replacement N/A U-BOLT /21" DIA.

03082

R/R# 01-02-217 ASME Xl, CLASS 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions for the ASME Code Section XI

1.

Owner:

Carolina Power & Light Date: 12/24/01 Name P.O. Box 1551, Raleigh, N.C. 27602-1551 Sheet 1

of 5

Address

2.

Plant:

Shearon Harris Nuclear Power Plant Unit 1 Name P0. Box 165. New Hill-N.C. 27562-0165 2'16.18 Address Repair Organization P.O. No., Job No., etc

3.

Work Performed by:

Becon Construction Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. Box 9, New Hill, N.C. 27562 Address Expiration Date N/A

4.

Identification of System:

UPPER LATERAL SUPPORT ON "A", "B", & "C" STEAM GENERATORS

5.

(a) Applicable Construction Code: ASME SEC III Edition 1974 Addenda Winter 76 Code Case N/A (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements: 1989 Addenda N/A

6.

Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board Identification:

Built Replaced Code No.

Or Stamped Replacement Yes/No See attached

7.

Description of Work: The existing Upper Lateral Support was removed during Steam Generator removal by separating the ring into two sections. This was accomplished by first removing the welded shim plates attached to the ULS bumpers and then removing the eight (8) splice joint bolts holding the ring halves together. The ring halves were then ridged out separately. The existing 140 rinqband shims were removed followed by VT and MT inspections. The splice goint bumper plates were drilled to receive the new bolted shim plate design and the kevways were drilled and tapped to accommodate the alternate bolted shim design. New adiustable deadweight trunnion supports were fabricated and installed on each ringband half. The rings were then rigged into place after the new steam generator was in place. A W finger shim plate was installed in each splice ioint to ensure the 1" gaap above the feedwater nozzle was achieved. Four (4) new 2 ?" x 12 W. bolts were installed in each splice ioint. Longer bolts were used because of the added shim thickness. Each ringband was adjusted to ensure proper elevation, 1" gap at the feedwater nozzle and snubber pin-to-pin dimensions and sway angles. Snubbers were re-attached and finger shims were installed-to achieve the proper cold gaps. New shim plates (56 per generator) were installed between the ringband and the steam gqenerator.

8.

Tests Conducted:

Hydrostatic [I Pneumatic 0 Nominal Operating Pressure [I Other 0 Pressure psi Test Temp.

-F NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 % in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12/82)

R/R# 01-02-217 ASME Xl, CLASS 2 Form NIS-2 Sheet 2 of 5

9.

Remarks Reference line 6 for code data reports.

Applicable Manufacturers Data Reports to be attached VT-3 was performed on the Upper Lateral Support after modification/installaiton CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repIcemPent conforms to the rules of the repair or replacement ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorizatio No.

NIA Expiration Date N/A Signed 441,Equipment Performance Supervisor Date

/

.20 jL Ofn-er of OK~ner'pesigffee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Nnrth PCaraina and employed by Hartford Steam Boiler Insoection and Insurance Comoany of One State Street.

Hartford-Connecticut 06102 have inspected the components described in this Owner's Report during the period 05-13-00 to 12-14-01

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

NC 1444NIAB Inspector's Signature National Board, State, Province, and Endorsements Date 20

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet Sheet 3

of 5

Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board Identification Built Replaced Code No.

Or Stamped Replacement Yes/No 2 /2"-4 UNC-2A CSC NA NA SA-540 UNK REPLACEMENT NO x 12-1/4" long heavy hex head GR. B23 bolt with 5 '2" thread length, CLASS 4 ASME SA-540 Gr. B23 HT. 10560 Class 4 conforming to ASME Section III, Subsection NF, 1974 Edition 2 2" - 4 UNC-2B T & T NA NA A-1 94 UNK REPLACEMENT NO Hex Nut, A194 Enterprises Gr. 2H GR.2H HT. 356 2 /" Standard A&G NA NA F-436 UNK REPLACEMENT NO Flat Circular Engineering II Washer, F436, INC.

HT. 146852 Type 1 1-8 UNC-2A T & T NA NA A-193 B7 UNK REPLACEMENT NO continuous Enterprises thread stud x 5 HT. 19639 Y2" long, A193 Gr. B7 1-8 UNC-2B Jam Korea Bolt IND NA NA A-194 GR.2H UNK REPLACEMENT NO Nut, A194 Gr. 2H Company HT.127789 1" Standard Flat Heidtman NA NA F-436 UNK REPLACEMENT NO Circular Washer, Steel Products F436 HT. 206518 Face Plate 3/4" x Corus NA NA A/SA-36 UNK REPLACEMENT NO 1'-9" x 11", A36 HT. ADX2054 Finger Shim Gulf States NA NA A/SA-36 UNK REPLACEMENT NO Plate 1" x 1'-8" x Steel, INC 11"', A36 HT. 7468855 Finger Shim Corus NA NA A/SA-36 UNK REPLACEMENT NO Plate V" x 1'-8" x 11", A36 HT. B1 P5527 Finger Shim Corus NA NA AISA-36 UNK REPLACEMENT NO Plate 1/414" x 1'-8" x 11", A36 HT. AOR0914

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet Sheet 4

of 5

Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board Identification Built Replaced Code No.

Or Stamped Replacement Yes/No Finger Shim Precision Steel NA NA A-109 UNK REPLACEMENT NO Plate 1/8" x 1'-8" Warehouse x 11", A109 HT. 65120PO COIL NO.

2652502 Finger Shim Gibraltar Strip NA NA A-109 UNK REPLACEMENT NO Plate 1/16" x 1'-

Steel, Inc.

8" x 11", A109 HT. 4126615 Finger Shim Nucor Steel NA NA A-366 UNK REPLACEMENT NO Plate 1/32" x 1' 8" x 11", A109 HT. 2007518 Finger Shim US Steel NA NA A/SA-36 UNK REPLACEMENT NO Plate 3/4" x 15" x Group 30", A36 HT. D04009 2 1"-4 1/" UNC-T & T NA NA A-193 GR B7 UNK REPLACEMENT NO 2A Heavy Hex Enterprises HT. 10199 Bolt x 4 /" long, threaded full HT. CODE length, A193 Gr.

B7, quenched ARV and tempered Plate 1 1/2/" x 4" x IPSCO Steel NA NA HT. B9B009 UNK REPLACEMENT NO 15" with slotted Inc.

hole, A572 Gr.

50 Plate 2 Y2" x 2 3/4/4" ATI Steel USA NA NA A-572 GR. 50 UNK REPLACEMENT NO xi5", A572 Gr.

Incorporated TYPE 2 50 HT. 1A747 Plate 1 /" x 2 /"

ATI Steel USA NA NA A-572 GR. 50 UNK REPLACEMENT NO x 9 3/44" end Incorporated TYPE 2 prepped, A572 Gr. 50 HT. 1A747 Shim Plate 1/8" x Greer Steel NA NA A-109 UNK REPLACEMENT NO 4" x 15", A109 Company HT. A11698 Shim Plate 1116" Gibraltar Strip NA NA A-109 UNK REPLACEMENT NO x 4" x 15", A109 Steel, Inc.

HT. 4158825 Plate 3/16" x 1 Bethlehem NA NA A/SA-36 UNK REPLACEMENT NO 1" x 3", A36 HT. R2097

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet Sheet 5

of 5

Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board Identification Built Replaced Code No.

Or Stamped Replacement Yes/No Plate 3/16" x 1 Bethlehem NA NA A-36 UNK REPLACEMENT NO 1" x 3", A36 HT. 421 S9471 Plate 5/16" x 4" x Benxi Iron NA NA A-36 UNK REPLACEMENT NO 7 3/4" w/ 2 3/8" 0 Hole, A36 HT. D9935897 Plate 3/32" x 4" x Gibraltar Strip NA NA A-109 UNK REPLACEMENT NO 5 Y" w/ 2 3/8" 0 Steel, Inc.

Hole, A109 HT. W06426 1/22-13 UNC-2A x T & T NA NA A-325 Type 1 UNK REPLACEMENT NO 3" long Heavy Enterprises Let #

Hex Bolt, A325 Type 1 911540-05 1/-13 UNC-2B Telefast NA NA A-194 GR. 2H UNK REPLACEMENT NO Heavy Hex Nut, Industries Inc.

A194 Gr. 2h HT. Y67408

/" Standard Flat Nova Machine NA NA F-436 TYPE 1 UNK REPLACEMENT NO Circular Washer, Products F436 Type I HT. A89192 LOT #

40029927 Plate 1" x 2" x Roanoke NA NA A-36 UNK REPLACEMENT NO 24", ASTM A36 Electric Steel Corporation HT. JB9175 Plate 3/4" x 2" x Roanoke NA NA A-36 UNK REPLACEMENT NO 24", ASTM A36 Electric Steel Corporation HT. JC6116 Plate 1/2" x 2" x Roanoke NA NA A-36 UNK REPLACEMENT NO 24", ASTM A36 Electric Steel Corporation HT. JC2016 Plate 1/4" x 2" x Roanoke NA NA A-36 UNK REPLACEMENT NO 24", ASTM A36 Electric Steel Corporation HT. JC5987 Angle 2-1/2" X 2-Roanoke NA NA A-36 UNK REPLACEMENT NO 1/2" X 1" Electric Steel Corporation HT. JC6341 Snubber Shim US Steel NA NA SA-36 UNK REPLACEMENT NO

/" x 6" x 16" Group HT. E04583 Snubber Shim US Steel NA NA SA-36 UNK REPLACEMENT NO 1" x 6" x 16" Group HT. Y08953

R/R# 01-02-218 ASME X1, CLASS 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions for the ASME Code Section XI

1.

Owner Carolina Power & Light Name P.O. Box 1551, Raleigh, N.C. 27602-1551 Address

2.

Plant:

Shearon Harris Nuclear Power Plant Name P-.. Box 165. New Hill-N.C. 27562-0165 Address

3.

Work Performed by:

Becon Construction Name P.O. Box 9, New Hill, N.C. 27562 Address

4.

Identification of System FEEDWATER (PIPING)

Date:

12/24/01 Sheet I of 3 Unit I Repair Organization P.O. No., Job No., etc Type Code Symbol Stamp N/A Authorization No.

N/A Expiration Date N/A

5.

(a) Applicable Construction Code: ASME Sec.lll Cl. 2 Edition 1974 Addenda Winter 76 Code Case N/A (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements: 19 89 Addenda NIA

6.

Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board Identification:

Built Replaced Code No.

Or Stamped Replacement Yes/No 16" SCH. 120 B.F. SHAW 97807-M-N/A PC. MK 97807-2001 REPLACEMENT YES PIPE 2031-S01 SA-106 Gr.B M-2031-SOI 16" SCH. 120 B.F. SHAW N/A N/A 97807-M-2032-2001 REPLACEMENT NO PIPE SA-106 Gr.B S01 16" SCH. 120 B.F. SHAW N/A N/A 9700807-M-2001 REPLACEMENT NO PIPE SA-106 Gr.B 2033-SOI 6", SCH.80, B.F. SHAW 97807-MI-N/A PC.MK. 97807-2001 REPLACEMENT YES SA-106 GR. B, 2029-S01 M-2029-S01 PIPE SPOOL 16", SCH. 120, B.F. SHAW 2FW16-67SN-NIA ISO. SK-2001 REPLACEMENT YES SA-335 P11, 1-A PIPE SPOOL 9700807-M-2000 16", SCH.80, B.F. SHAW 2FW16-67SN-N/A ISO. SK-2001 REPLACEMENT YES SA335 Pll 1-B 9700807-M-2000 PIPE SPOOL

R/R# 01-02-218 ASME XI, CLASS 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet Sheet 2 of 3 Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board No.

Identification:

Built Replaced Code Or Stamped Replacement Yes/No 16" SCH. 80, B.F. SHAW N/A NA PC.MK. 2FW16 2001 REPLACEMENT NO SA-234 WP1 1, 450 ELL

-67SN-1-C 16" SCH. 80, B.F. SHAW N/A N/A PC.MK. 2FW16 2001 REPLACEMENT NO SA234 WP11-S, S/R 900 ELL

-67SN-1-D 16", SCH. 120, B.F. SHAW 2FW16-68SN-N/A PC.MK.2FW16-2001 REPLACEMENT YES SA-335 P11, 1-A PIPE SPOOL 68SN-1-A 16", SCH. 80, B.F. SHAW 2FW16-68SN-N/A PC.MK.2FW16-2001 REPLACEMENT YES SA-335 P11, 1-B 68SN-1-B PIPE SPOOL 16", SCH. 80, B.F. SHAW 2FW16-68SN-N/A PC.MK.2FW16-2001 REPLACEMENT YES SA-335 P11, 1-C 68SN-1-C PIPE SPOOL 16", SCH. 80, B.F. SHAW 2FW16-68SN-N/A 2FW16-68SN-2001 REPLACEMENT YES SA-335 P11, PIPE SPOOL 1-D 1-D 16", SCH. 120, B.F. SHAW 2FW16-69SN-N/A 2FW16-69SN-2001 REPLACEMENT YES A-335 P11, PIPE 1-A 1-A SPOOL 16", SCH. 80, B.F. SHAW 2FW16-69SN-N/A 2FW16-69SN-2001 REPLACEMENT YES SA-335 P11, PIPE SPOOL 1-B 1-B 16" SCH. 80, B.F. SHAW 2FW16-69SN-N/A 2FW16-69SN-2001 REPLACEMENT NO SA-234 WP11, 1-C 1-C 450 ELL 16" SCH. 80, B.F. SHAW 2FW16-69SN-N/A 2FW16-69SN-2001 REPLACEMENT NO SA234 WP11-S, 1-D 1-D S/R 90" ELL

7.

Description of REMOVE AND REPLACE I-W PIPING IN MSTI ANU -CB.

8.

Tests Conducted:

Hydrostatic [I Pneumatic 0l Nominal Operating Pressure 0 Other E]

Pressure psi Test Temp.

-F NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 % in. x 11 in., (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12/82)

R/R# 01-02-218 ASME Xl, CLASS 2 Form NIS-2 Sheet 3

of 3

9.

Remarks Reference line 6 for code data reports.

Applicable Manufacturer's Data Reports to be attached VT-2 performed per requirements of Code Case N-416-1.

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this rnlac.ment conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A CertificaofAuthorizatio

o.

N/A Expiration Date N/A Signed Equipment Performance Supervisor Date

/

-20 j

  • t~er or i*,ne

_Migee, Ttl CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Nnrth (hrnlina and employed by Hartford Steam Boiler Inspection and Insurance Comoanv of One State Street.

Hartford. Connecticut 06102 have inspected the components described in this Owner's Report during the period 05-13-00 to 12-14-01

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspectin Commissions NC 1444NIAR Inspector's Signature National Board, State, Province, and Endorsements Date.

  • "--L-

' 20 OE..-

R/R# 01-02-219 ASME XI, CLASS 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions for the ASME Code Section Xl

1.

Owner:

Carolina Power & Light Date: 12/24/01 Name P.O. Box 1551, Raleigh, N.C. 27602-1551 Sheet 1

of 6

Address

2.

Plant:

Shearon Harris Nuclear Power Plant Unit 1 Name P.O-Box 165. New Hill. N.C. 27562-0165 5-161 Address Repair Organization P.O. No., Job No., etc

3.

Work Performed by:

Becon Construction Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. Box 9, New Hill, N.C. 27562 Address Expiration Date N/A

4.

Identification of System:

FEEDWATER (HANGERS)

5.

(a) Applicable Construction Code: ASME Sec III Edition 1974 Addenda Winter 76 Code Case N/A (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements: 1989

" Addenda N/A

6.

Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board Identification:

Built Replaced Code No.

Or Stamped Replacement Yes/No See attached

7.

Description of Work: The existing Feedwater pipe and supports inside the Bio-wall were removed and rerouted to the new location of the Feedwater nozzle no the new steam generators. New hangers were installed and some old hangers outside the bio wall were modified. Supports in the steam tunnel were also modified.

8.

Tests Conducted:

Hydrostatic 0]

Pneumatic El Nominal Operating Pressure [I Other 0l Pressure psi Test Temp.

OF NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12/82)

R/R# 01-02-219 ASME X1, CLASS 2 Form NIS-2 Sheet 2 of 6

9.

Remarks Reference line 6 for code data reports.

Applicable Manufacturer's Data Reports to be attached VT-3 was performed after the hanger modifications/installations.

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the repair or replacement ASME Code,Section XI.

Type Code Symbol Stamp NIIA Certificate of Authorization No.

N/A Expiration Date N/A Signed 4-

/

quipment Performance Supervisor Date -/

/

20

'2 S(er or COwne14 Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Comoanv of One State Street.

Hartford, Connecticut 06102 have inspected the components described in this Owner's Report during the period 05-13-00 to 12-24-01

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's ReporL Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

"___

Commissions NC 1444NI AB

~"~-In-spector's Signature National Board, State, Province, and Endorsements Date

- c-'

20

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet Sheet 3

of 6

Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board No.

Identification:

Built Replaced Code Or Stamped Replacement Yes/No Plate 1" x 12" x CitiSteel USA N/A N/A HT# 1B090 Unk Replacement No 1'-6 1/2" ASME SA-36 Plate 1" x 10 1/2" x USS Group N/A N/A HT# Y08953 Unk Replacement No 1'-6 1/2" ASME SA-36 Plate 1/2" x 6 1/2" Nucor Steel N/A NIA HT# 1011493 Unk Replacement No x 6 1/2" Plate 5 7/8" x 10" x USS Group N/A N/A HT# Y08953 Unk Replacement No 7/8" x 5/8" ASME SA-36 Crushable Material Provided by N/A N/A P/N 76325405 Unk Replacement No CP&L P.O. # 24842 16" riser clamp Bergen-Power N/A N/A B.P. # 86207 Unk Replacement No Tube Steel 1/2" x Leavitt Tube N/A N/A HT#

Unk Replacement No 8"x 6"x 2'-2" Ig.

Co.

813P66080 ASTM A500, Gr. B Plate 1/2"x 10"x Feralloy Corp.

N/A N/A HT# 2104415 Unk Replacement No 10" Ig.

1 1/4" x 11 1/2" 1g.

Provided by N/A N/A CP&L P/N Unk Replacement No stud CP&L 72853112 1 1/4" Heavy Hex Provided by NIA N/A CP&L P/O #

Unk Replacement No Nuts CP&L REQ 165 Short Strut Bergen-Power N/A N/A B.P. # 2411-50 Unk Replacement No Assembly Tube Steel 1/2" x Independence N/A N/A HT# T21326 Unk Replacement No 8" x 6" x 10W-"

Ig.

Tube Corp.

ASTM A-500, Gr. B Plate 3/4" x 10" x Corus N/A N/A HT# BOX7262 Unk Replacement No 1-2" ASME SA-36 Tube Steel 1/2" x Independence N/A N/A HT# D00659 Unk Replacement No 6" x 6" x 8'-0" Ig.

Tube Corp.

ASTM A-500, Gr. B Plate 1" x 9 114" x CitiSteel USA N/A N/A HT# N460 Unk Replacement No 1-6 1/2" ASME SA-36 Plate 1/2" Ferralloy N/A N/A HT# 2104415 Unk Replacement No Corp.

Shim Plate 1 1/2" x Gulf States N/A N/A HT# 7459350 Unk Replacement No 7"x 10" Steel ASME SA-36 Rigid Strut Bergen-Power N/A N/A B.P. # 2200-50 Unk Replacement No 16" Pipe Clamp Bergen-Power N/A N/A B.P. # 2600-50 Unk Replacement No Plate 1 1/4" x 9" x Gulf States N/A N/A HT# 7464918 Unk Replacement No 11" Steel ASME SA-36 Plate 1" x 1 '-0" x Gulf States N/A N/A HT# 7473991 Unk Replacement No 1 '-0" Steel ASME SA-36 Rigid Telescoping Bergen-Power NIA N/A B.P. # 2100-50 Unk Replacement No Strut Tube Steel 3/8" x LTV N/A N/A HT# U01 166 Unk Replacement No 6" x 6" Copperweld ASTM A500, Gr. B 16" Pipe Clamp Bergen-Power N/A N/A B.P. # 2640-50 Unk Replacement No Plate 1/2" x 6" x 6" Corus N/A N/A HT# BIP5527 Unk Replacement No ASME SA-36

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet Sheet 4

of 6

Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board No.

Identification:

Built Replaced Code Or Stamped Replacement Yes/No Tube Steel 1/2" x LTV N/A N/A HT# FF934249 Unk Replacement No 5" x 5" Copperweld ASTM A500, Gr. B Plate 1/4" x 4 3/4" x Corus NIA N/A HT# AOR-0914 Unk Replacement No 4 3/4" ASME SA-36 Weld Attachment Bergen-Power N/A N/A B.P. # 1001-50 Unk Replacement -

No 8" Sch, 80 Pipe, USS Group N/A N/A HT# C66845 Unk Replacement No 8" Ig.

SA-106, Gr. B Rigid Strut Bergen-Power N/A N/A B.P. # 2250-60 Unk Replacement No FW-H-800 Structural Bergen-Power N/A NIA B.P. # 1000-60 Unk Replacement No Attachment Tube Steel 1/2" x LTV NIA NIA HT# 57789 Unk Replacement No 6" x 6" x 1V-9" Ig Copperweld ASTM A500, Gr. B Plate 2" x 2'-2 3/4" Gulf States N/A N/A HT# 7467493 Unk Replacement No x 5-6 1/4" Ig Steel ASME SA-36 W12 x 79 x 1'-6" 1g. Nucor-Yamato N/A N/A HT# 170918 Unk Replacement No 5" Sch, 80 Pipe Dubose N/A N/A HT#

Unk Replacement No National SLNN80007 Energy Mech. Snubber Bergen-Power N/A N/A B.P. # 2540 Unk Replacement No Tube Steel 1/2" x Atlas Tube N/A NIA HT# 864280 Unk Replacement No 6" x 10" x 1'-6" Ig ASTM A500, GR. B End Attachment Bergen-Power N/A N/A B.P. # 2003 Unk Replacement No Tube Steel 1/2" x LTV N/A NIA HT# Y88651 Unk Replacement No 6" x 4" Copperweld ASTM A500, GR. B Tube Steel 1/2" x Bethlehem N/A N/A HT#

Unk Replacement No 4" x 4" Steel Corp.

833L65720 Plate 1/2" x 6" x Roanoke N/A N/A HT# JC3653 Unk Replacement No 3'-5" Ig.

Electric Steel ASTM SA-36 Plate 3/4" x 6" x USS Group N/A N/A HT# D02407 Unk Replacement No 3'-3" Ig.

ASM SA-36 Plate 1" x 16" x Gulf States N/A N/A HT# 7472446 Unk Replacement No 3'-0" Ig.

Steel ASME SA-36 Tube Steel 1/2" x Independence N/A N/A HT# S07944 Unk Replacement No 6" x 4" Tube Corp.

ASTM A-500, Gr. B Plate 3/4" x 7 1/2" x Corus N/A N/A HT# AOX2054 Unk Replacement No 8" Ig.

ASME SA-36 Tube Steel 1/2" x Independence N/A N/A HT# D00659 Unk Replacement No 6" x 6" Tube Corp.

ASTM A-500, Gr. B Tube Steel 1/2" x Hanna Steel N/A N/A HT# B9S5827 Unk Replacement No 8" x 8" Corp.

ASTM A500, Gr. B Welded Beam Bergen-Power N/A N/A B.P. # 1047 Unk Replacement No Attachment Variable Spring Bergen-Power N/A N/A B.P. # 3200 Unk Replacement No Heavy Hex Nut, Bergen-Power N/A N/A B.P. # 5400 Unk Replacement No 1-1/4"

_j

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet Sheet 5

of 6

Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board No.

Identification:

Built Replaced Code Or Stamped Replacement Yes/No Continuous Th'd Bergen-Power N/A N/A B.P. # 5006 Unk Replacement No

Rod, 1-1/4" Weldless Eye Nut, Bergen-Power N/A N/A B.P. # 5130 Unk Replacement No 1-1/4" Tube Steel 5/16" x L'V N/A N/A HT# D0001 1 Unk Replacement No 4" x 2" x V-10" Ig -

Copperweld ASTM A500, Gr. B 16" Long Tangent Bergen-Power N/A N/A B.P. # 6504 Unk Replacement No U-Bolts, w/ nuts Mech. Snubber Bergen-Power N/A N/A B.P. # 2411 Unk Replacement No 16" Pipe Clamp Bergen-Power N/A N/A B.P. # 2640-50 Unk Replacement No Plate 3/4" x 6 1/2" x CitiSteel USA N/A N/A HT# 1 C636 Unk Replacement No 10" Ig.

ASME SA-36 Rigid Strut Bergen-Power N/A N/A B.P. # 2100-28 Unk Replacement No 16" Pipe Clamp Bergen-Power N/A N/A B.P. # 2600-28 Unk Replacement No 16" Pipe Clamp Bergen-Power NIA N/A B.P. # 86208 Unk Replacement No Strut & Snubber Bergen-Power N/A N/A B.P. # 2540-50 Unk Replacement No Shim-21 gage Ameristeel, N/A N/A HT# 14361 Unk Replacement No Inc.

ASTM A-570 Shim - 10 gage Lone Star N/A N/A HT# 77503 Unk Replacement No Steel Company ASTM A-570 16" Pipe Clamp Bergen-Power N/A N/A B.P. # 2600-30 Unk Replacement No Rigid Strut Bergen-Power N/A N/A B.P. # 2200-30 Unk Replacement No Plate 1 1/2" x 2'-4" Gulf States N/A N/A HT# 7459350 Unk Replacement No x 2'-4" Ig.

Steel ASME SA-36 Maxi Bolt 1 1/4" Drillco N/A N/A Unk Replacement No Dia. x 22" 1g.

Tube Steel 1/4" x Leavitt Tube N/A N/A HT# 8591 9K Unk Replacement No 4" x 4" Company ASTM A-500, Gr. B Snubber Bergen-Power N/A NIA B.P. # 2411-50 Unk Replacement No W8 x 31 Nucor Steel N/A N/A HT# 1103333 Unk Replacement No W8 x 31 Northwestern N/A N/A HT# 81627 Unk Replacement No Steel ASME SA-36 End Attachment Bergen-Power N/A N/A B.P. # 2003-50 Unk Replacement No Plate 2" x 2'-4 3/4" Gulf States N/A N/A HT# 7455148 Unk Replacement No x 3'-9 1/2" Steel ASME SA-36 3" Sch, 80 Pipe USS Group N/A N/A HT# L40039 Unk Replacement No SA-106, Gr. B 16" Pipe Clamp Bergen-Power N/A N/A B.P. # 6150 Unk Replacement No Weldless Eye Nut, Bergen-Power N/A N/A B.P. # 5130 Unk Replacement No 1"

Continuous Th'd Bergen-Power N/A N/A B.P. # 5006 Unk Replacement No Rod, 1"x2'-3"lg

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet Sheet 6

of 6

Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board No.

Identification:

Built Replaced Code Or Stamped Replacement Yes/No Tube Steel 3/8" x USS Group N/A N/A HT# Y05656 Unk Replacement No 4 x 4"xx 1'Ig Heavy Hex Nut, Bergen-Power N/A N/A B.P. # 5400-1 Unk Replacement No 1"

Heavy Hex Nut, Korea Bolt N/A N/A HT# IR ASTM Unk Replacement No 1"

Ind.

A194, GR. 2H Restraint Yoke Bergen-Power N/A N/A B.P. # 6175-25 Unk Replacement No Clamp FW-H-807 Rigid Strut Bergen-Power N/A N/A B.P. # 2250-25 Unk Replacement No Rigid Strut, Size 10 Bergen-Power N/A N/A B.P. # 2200 Unk Replacement No 16" Pipe Clamp, Bergen-Power N/A N/A B.P. # 2600 Unk Replacement No Size 10 Tube Steel 1/2" x LTV N/A N/A HT# E06300 Unk Replacement No 12" x 8" x 3'-6" Ig.

Copperweld ASTM A500, Gr. B Maxi Bolt 1 1/4" Drillco N/A N/A Unk Replacement No Dia. x 23" Ig.

R/R# 01-02-220 ASME XI, Class 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions for the ASME Code Section Xl

1.

Owner:

Carolina Power & Light Date:

12/24101 Name P.O. Box 1551, Raleigh, N.C. 27602-1551 Sheet 1

of 3

Address

2.

Plant Shearon Harris Nuclear Power Plant Unit 1 Name P-.o Box 165. New Hill-N.C. 27562-0165 2316R1 Address Repair Organization P.O. No., Job No., etc 1

3.

Work Performed by:

Becon Construction Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. Box 9, New Hill, N.C. 27562 Address Expiration Date NIA

4.

Identification of System:

LOWER LATERAL SUPPORT ON "A", "B", & "C" STEAM GENERATOR

5.

(a) Applicable Construction Code: ASME Sec III Edition 1974 Addenda Winter 76 Code Case N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 198L Addenda N/A

6.

Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board Identification:

Built Replaced Code No.

Or Stamped Replacement Yes/No See attached

7.

Description of Work: The existing Lower Lateral Supports were modified during Steam Generator repacement by cutting out the existing welded shims. Following shim removal from the support structures, the supports were subiected to VT and MT inspections. The structures were then drilled to receive the new bolted shim plate design. New face plates were installed using 5/8*

studs attached to the face plates at drilled and tapped holes. One shim was tapered to provide a flat surface and finger shims of various sizes were then installed to provide the desired -gap at cold conditions. Hot Gap Testing was performed at approximately 1950F. 3450F. 4501F and 557°F to ensure that the desired gaps were achieved at normal operating temperatures.

8.

Tests Conducted:

Hydrostatic [I Pneumatic [I Nominal Operating Pressure [I Other E]

Pressure-psi Test Temp.

-F NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 / in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12/82)

R/R# 01-02-220 ASME Xl, Class 2 Form NIS-2 Sheet 2 of "3

9.

Remarks Reference line 6 for code data reports.

Applicable Manufacturer's Data Reports to be attached VT-3 performed after Lower Lateral Support modification CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacemPnt conforms to the rules of the repair or replacement ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No.

NIA Expiration Date NIA F

Signed D g--v, -

o-*-

1Equipment Performance Supervisor Date Ii0 0

fr~ner or Ownr Desigl*ee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Nnrth C'nrnlina and employed by Hartford Steam Boiler Inspection and Insurance Comoanv of One State Street, Hartford, Connecticut 06102 have inspected the components described in this Owner's Report during the period 05-13-00 to 12-24-01

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Commissions NC 1444NI AB Inspector's Signature National Board, State, Province, and Endorsements Date Z--'

20

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet Sheet 3

of 3

Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board No.

Identification:

Built Replaced Code Or Stamped Replacement Yes/No Plate 314" xl'-7 1/2" Corus N/A N/A HT# AOX2054 Unk Replacement No x 1'-2-1/8" with (6) holes drilled and ASME SA-36 tapped 1-8 UNC-2A T & T N/A N/A HT# 19639 Unk Replacement No continuous thread Enterprises ASME SA1 93 stud x 8" long B7 1-8 UNC-2A Texas Bolt N/A N/A HT# 61606 Unk Replacement No continuous thread Co.

ASME SA1 93 stud x 7" long B7 1" 0 Standard Flat Prestige N/A N/A HT # 206518 Unk Replacement No Circular Washer Stamping, Inc.

ASTM F-436 1-8 UNC-2B Hex Unityte, Inc.

N/A N/A HT # S41165 Unk Replacement No Nut SA-194, Gr. 2H 1-8 UNC-2B Jam T & T N/A N/A HT # 127789 Unk Replacement No Nut Enterprises SA-1 94, Gr. 2H Finger Shim Plate, Corws N/A N/A HT # BIP 5527 Unk Replacement No 1/2"x 1'-2 1/8"x ASME SA-36 1'-7 1/2" Finger Shim Plate, Corus N/A N/A HT # BIQ 5806 Unk Replacement No 3/8"x 1-2 1/8"x ASME SA-36 1'-7 1/2" Finger Shim Plate, Corus N/A N/A HT # AOR0914 Unk Replacement No 1/4"x V-2 1/8"x ASME SA-36 1'-7 1/2" Finger Shim Plate, Consolidated N/A N/A HT # 65120PO Unk Replacement No 1/8" x 1'-2 1/8" x Power Supply ASTM A-109, 1V-7 1/2" Gr. 1010 Finger Shim Plate, Consolidated N/A N/A HT # 4126615 Unk Replacement No 1/16" x 1-2 1/8" x Power Supply ASTM A-109, 1'-7 1/2" Gr. 1010 Finger Shim Plate, Consolidated N/A N/A HT # 64001 Unk Replacement No 1/32" x 1'-2 118" x Power Supply ASTM A-109, 1'-7 1/2" Gr. 1010