March 27, 2002 Mr. L. W. Myers Senior Vice President FirstEnergy Nuclear Operating Company Beaver Valley Power Station Post Office Box 4 Shippingport, PA 15077

SUBJECT:

BEAVER VALLEY POWER STATION, UNIT 1 (BVPS-1) - NUCLEAR REGULATORY COMMISSION (NRC) STAFF REVIEW OF LICENSE AMENDMENT REQUEST REGARDING THE USE OF THE WESTINGHOUSE MASTER CURVE METHODOLOGY (TAC NO. MB3902)

Dear Mr. Myers:

By letter dated January 25, 2002, FirstEnergy Nuclear Operating Company (FENOC) requested a license amendment involving Technical Specification changes associated with the BVPS-1 heatup/cooldown curves, the power-operated relief valve setpoint, and overpressure protection system enable temperature. The proposed changes are based on the Westinghouse Master Curve Methodology.

The NRC Materials and Chemical Engineering Branch technical staff has completed an acceptance review of your submittal and has determined that your proposal with regard to the treatment of unirradiated sample data is not technically justified. Specifically, when compared to test results of irradiated material samples, the manner in which you have treated the unirradiated sample data does not accurately characterize initial material properties of the BVPS-1 reactor pressure vessel, or the changes to those material properties that result from irradiation. When both of these factors are considered, applying the Master Curve Methodology would yield non-conservative results for the end of license reference temperature, RTPTS, and adjusted reference temperatures necessary for the determination of BVPS-1 pressure-temperature limits.

In a telephone conference with your staff on February 22, 2002, the NRC technical staff provided its preliminary assessment of the January 25, 2002, submittal and requested that your staff consider revising the manner in which unirradiated sample data is used to establish the technical basis for the proposed changes. FENOC staff stated that they understood the nature of the NRC staffs concerns and that they would evaluate supplementing or revising the subject submittal.

Subsequent to the February 22, 2002, conference call, FENOC staff communicated to the NRC project manager for Beaver Valley that FENOC is working on a submittal to revise, in part, the January 25, 2002, application. Your staff stated that April 15, 2002, was the target date for submission of that supplemental submittal. In a later communication, on or about March 19, 2002, FENOC staff requested a meeting with the NRC technical staff, to be held on or about April 23, 2002, to discuss the NRC staffs concerns. FENOC staff indicated that the supplement to the application will be submitted after the proposed meeting.

L.W. Myers Pending the receipt of this expected supplemental submittal, the NRC staffs review of your January 25, 2002, application has been temporarily discontinued. The review will be resumed once your supplemental submittal is received. For planning purposes, the date of receipt of the supplemental submittal will be considered to be the initiation date of the NRC staff review.

Please be advised that our planning horizon for review of licensing actions such as this is typically 1 year.

Should you be unable to provide a supplemental submittal to the January 25, 2002, application in a timely manner following a meeting with the NRC technical staff, you will need to discuss the review schedule with the NRC staff. It may be appropriate for you to withdraw the application and resubmit once you have been able to reevaluate the technical basis for the proposed amendment.

Sincerely,

/RA/

Elinor G. Adensam, Director Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-412 cc: See next page

L.W. Myers Pending the receipt of this expected supplemental submittal, the NRC staffs review of your January 25, 2002, application has been temporarily discontinued. The review will be resumed once your supplemental submittal is received. For planning purposes, the date of receipt of the supplemental submittal will be considered to be the initiation date of the NRC staff review.

Please be advised that our planning horizon for review of licensing actions such as this is typically 1 year.

Should you be unable to provide a supplemental submittal to the January 25, 2002, application in a timely manner following a meeting with the NRC technical staff, you will need to discuss the review schedule with the NRC staff. It may be appropriate for you to withdraw the application and resubmit once you have been able to reevaluate the technical basis for the proposed amendment.

Sincerely,

/RA/

Elinor G. Adensam, Director Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-412 cc: See next page DISTRIBUTION:

PUBLIC MO'Brien ACRS EAdensam JZwolinski PDI-1 Reading DCollins JMunday MOprendek, RGN-I WBateman MMitchell OGC AHiser LLois FAkstulewicz Accession Number: ML020860505

  • See previous concurrence OFFICE PDI-1/PM PDI-1/LA EMCB/BC PDI-1/(A)SC PDI-1/D DLPM/D NAME DCollins MOBrien WBateman*

JMunday EAdensam JZwolinski DATE 03/21/02 03/22/02 03/13/02 03/23/02 03/25/02 03/25/02 OFFICIAL RECORD COPY

Beaver Valley Power Station, Units 1 and 2 Mary OReilly, Attorney FirstEnergy Nuclear Operating Company FirstEnergy Corporation 76 South Main Street Akron, OH 44308 FirstEnergy Nuclear Operating Company Regulatory Affairs/Corrective Action Section Larry R. Freeland, Manager Beaver Valley Power Station Post Office Box 4, BV-A Shippingport, PA 15077 Commissioner James R. Lewis West Virginia Division of Labor 749-B, Building No. 6 Capitol Complex Charleston, WV 25305 Director, Utilities Department Public Utilities Commission 180 East Broad Street Columbus, OH 43266-0573 Director, Pennsylvania Emergency Management Agency 2605 Interstate Dr.

Harrisburg, PA 17110-9364 Ohio EPA-DERR ATTN: Zack A. Clayton Post Office Box 1049 Columbus, OH 43266-0149 Dr. Judith Johnsrud National Energy Committee Sierra Club 433 Orlando Avenue State College, PA 16803 L. W. Pearce, Plant Manager (BV-IPAB)

FirstEnergy Nuclear Operating Company Beaver Valley Power Station Post Office Box 4 Shippingport, PA 15077 Bureau of Radiation Protection ATTN: Larry Ryan P O Box 2063 Harrisburg, PA 17120 Mayor of the Borough of Shippingport P O Box 3 Shippingport, PA 15077 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Resident Inspector U.S. Nuclear Regulatory Commission Post Office Box 298 Shippingport, PA 15077 FirstEnergy Nuclear Operating Company Beaver Valley Power Station ATTN: M. P. Pearson, Director Services and Projects (BV-IPAB)

Post Office Box 4 Shippingport, PA 15077 FirstEnergy Nuclear Operating Company Beaver Valley Power Station Mr. B. F. Sepelak Post Office Box 4, BV-A Shippingport, PA 15077