ML020740419

From kanterella
Jump to navigation Jump to search
Part 1 of 3, Revision 0 to TR-151, Report on 2001 Outage 1R14 Eddy Current Examinations of TMI-1 OTSG Tubing
ML020740419
Person / Time
Site: Crane 
Issue date: 02/28/2002
From: Navratil G
AmerGen Energy Co
To:
Office of Nuclear Reactor Regulation
References
TR-151, Rev 0
Download: ML020740419 (159)


Text

0

  • 1 0

-Ti C7 0

(A-

'-I 0

LI

-0

0

'-I m

0"*

0~

(A

-1 C $-a 0

C

-I 0

Elm

CONTENTS Report on 2001 Outage 1R14 Eddy Current Examinations of TMI-1 OTSG Tubing Abstract of Pressure Boundary and Component Support Examinations Abstract of Pressure Tests ENCLOSURE 2 NIS-2 Reports - Documentation of Repairs/Replacements AVERY0 EXECUTIVE READY INDEXO DIVIDERS No. 8

) I S!

I

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisons of the ASME Code Rules I. Owner AmerGen Engerv Comp.LLC (Name and Address of Owner)

2. Plant Three Mile Island Nuclear Generating Station, Rt 441 South, Middletown, Pennsylvania (Name and Address of Plant)
3. Unit Unit 1
4. Owner Certificate of Authoriztion (if required)

N/A Commercial Service Date 09/02/74

6. National Board Number for Unit Reactor Vessel N-109
7. Components Inspected See Table I Manufacturer Component or Manufacturer or Installer State or Appurtenance or Installer Serial No.

Providence No.

',ý oard No.

\\\\\\Jl Note: Supplemental sheets in form of lists, sketches. or drawings may be used provided (1) size is 8 1/2 in. x 11 in.. (2) information in items I through 6 on this data report is included on each sheet, and (3) each sheet is numbered and the number of sheets recorded at the top of this form.

FORM NIS-1 (back)

8. Examination Dates 03-07-00 to 12-06-01 9.1nspection Interval from 1991to 2001, 2ndlnterval*

and, 2001 to 2011, 3rd Interval** and 2001 to 2011 1st Interval *

10. Applicable Editions for Section XI! Addenda
  • Section XI 1986 Addenda None for Subsections IWB, IWC, IWD and IWF
    • Section XI 1995 Addenda 1996 for Subsections IWB, IWC, IWD, and IWF
      • Section XI 1992 Addenda 1992 for Subsections IWE, and IWL
11. Abstract of Examinations. Include a list of examinations and a statement concerning status of work required for current interval. See Table 1, for IWB, IWC, IWD, IWE, and IWF.

See Attachment 1 for Steam Generator Eddy Current.

12. Abstract of Conditions Noted. See Table 2. See Attachment I for Steam Generator Eddy Current.
13. Abstract of Corrective Measures Recommended and Taken. See Table 2. See Attachment 1 for Steam Generator Eddy Current.

Certificate of Authorization No. (if applicable) N/A Expiration Date N/A We certify that the statements made in this report are correct and the examinations and corrective measures taken conform to the rules of the ASME Code,Section XI.

Date

/)

cQ-/Q Signed AmerGen Energy Co, LLC By ISI, Program Engineer CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and/or the State or Province of PENNSYLVANIA and employed by H.S.B 1&I CO. of CT.

have inspected the components described in this Owners' Data Report during the period 03-07-00 to 12-06-01 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners' Data Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Date Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Date pr

~

O?

Commissions N 4S- (0)4).

11 l881 Inspector's S-gnature National Board-State, Province and No.

Report on the 2001 Outage 1R14 Eddy Current Examinations of the TMI-1 OTSG Tubing Topical Report Number:

151 (Rev 0

)

Gene Navratil,1.

Author Richard Freeman Reviewer Design Verification Required?

N/A Design Verification Engineer

/ Datfe 2-?,-I-Z.oo-2 Date D YES N/A Date W-*NO If yes - DV#:

N/A Richard Barley-t 34 --

Z Section Manager (7

'Date

TR-151, Revision 0 Summary of Change 0

Original report issued to document Outage 1R14 eddy current examination results reported LVt L!UC j*KI.,

2

TR-151, Revision 0 TABLE. OF CONTENTS PAGE NO.

1.

INTRODUCTION Ii.

METHODS A.

DATA ACQUISIT TON 5

1.

Tube Bobbin Coil Examinations 8

2.

Sleeve Bobbin Coil Examinations 8

3.

Motorized Rotating Pancake Coil (MRPC) Tube Examinations 8

4.

Plus Point Examination of Sleeves 8

5.

B&W Rolled Plug ECT Examinations 8

6.

Explosively Welded Plug Examinations 9

7.

Westinghouse Rolled Plug ECT Examinations 9

B.

DATA ANALYSIS PROCESS 9

1.

Data Analyst Qualifications 9

2.

Data Analysis Sequence 9

3.

Data Analysis Software 10

4.

Recording of Indications 10

5.

Data Management 11 C.

DISPOSITION OF RESULTS 11

1.

Inside Diameter IGA 11

2.

Kinetic Expansion Region 12

3.

Other Indications 13 D.

IN-SITU PRESSURE TESTING 13

1.

Pressure Test Process 13

2.

Tube Selection 14 III.

OUTAGE 12R EXAMINATION CATEGORIES AND RESULTS 21 A.

SCOPE SELECTION 21 B.

EXAMINATION RESULTS 31

1.

Tube Examinations (unexpanded region) 31

2.

Kinetic Expansion Examinations 39

3.

Lower Tubesheet Examinations 41

4.

Sleeve Examinations 41

5.

Severed Tube B66-130 41

6.

Plug Examinations 43 C.

IN-SITU PRESSURE TESTING RESULTS 43 IV.

REPAIRS PERFORMED 43 A.

TUBES PLUGGED DUE TO EDDY CURRENT RESULTS 43 B.

TUBES PLUGGED TO PREVENT SEVERED TUBE FAILURE 45 C.

PLUGGED TUBE REPAIRS 49 3

TR-151, Revision 0 TABLE OF CONTENTS V.

CONDITION ASSESSMENTS A.

CONDITION MONITORING B

OP~,ERA'TIONAL ASSESSTMEr7Nr-VI.

CONCLUSIONS VII.

REFERENCES Total Pages Main Body = 52 Total Pages = 381 B&W Rolled Sleeve TMI-l OTSG Design Information OTS G-A Kinetic Expansion Locations OTSG-B Kinetic Expansion Locations OTSG-A Sleeve Examination Locations OTSG-B Sleeve Examination Locations OTSG-A Lower Tubesheet Examination Locations OTSG-B Lower Tubesheet Examination Locations Outage 1R14 Technique Qualifications In Situ Test List and Results: OTSG-A In Situ Test List and Results: OTSG-B Laboratory Pressure Test List and Results: OTSG-B Bobbin Coil Tube Examination Scope MRPC Tube Examinations Sleeve Examinations Plug Examinations Summary of ID IGA Growth from 13R to 1R14 Predicted MSLB Leak Rate vs. Axial Extent for Volumetric ID IGA Indications Leakage Results and Inputs for Volumetric ID IGA Indications Growth of Support Plate Wear Indications Dent Voltage and Voltage Growth Statistics for OTSG-A Dent Voltage and Voltage Growth Statistics for OTSG-B Confimled Outside Diameter Indications OTSG-A Kinetic Expansion Examination Results OTSG-B Kinetic Expansion Examination Results Kinetic Expansion Theoretical Leakage Summauy OTSG-A Tubes Removed From Service For Eddy Current Indications OTSG-A Tubes Removed From Service For Eddy Current Indications Tubes Plugged to Capture Adjacent Tubes Appendix I Analysis Codes Appendix II Recordable Indications Number of Pages 4

PAGE NO.

49 49 50 51 51 Figure II-I Figure 11-2 Figure III-I Figure 111-2 Figure Ifl-3 Figure 111-4 Figure 111-5 Figure 111-6 Table II-1 Table 11-2 Table 11-3 Table 11-4 Table III-1 Table 111-2 Table 111-3 Table 111-4 Table 111-5 Table 111-6 Table 111-7 Table 111-8 Table 111-9 Table III-10 Table III-11 Table 111-12 Table 111-13 Table 111-14 Table 111-15 Table 111-16 Table 111-17 19 20 25 26 27 28 29 30 6

16 17 18 21 22 23 24 353 35 35 36 37 37 38 40 40 41 44 45 46 4

325

TR-151, Revision 0

1.

INTRODUCTION On October 9, 2001, TMI-1 was shut down for Refueling Outage 1R14. During this refueling outage, TMI-1 performed Eddy Current (ECT) examinations of the Once Through Steam Generators (OTSGs). The scope of the examinations includdtubig,,l.S d plug.Te exam-inations were required b) 141-Spcciiaton.

fence 1). Technical Specification License Amendment #237 (Reference 2), and TMI-1 engineering requirements.

During Outage lRl4 all. in-service tubes were cxamined with a bobbin coil probe and approximately 39% of the upper tubesheet kinetic expansions were examined with a rotating probe. In OTSG-A, eddy current examinations were performed on 14,195 in-service tubes, 82 sleeves, and 157 installed plugs. In OTSG-B, eddy current examinations were performed on 15,127 in-service tubes, on 85 sleeves, and 88 installed plugs. The examinations determined that previously plugged tube B66-130 became severed and impacted adjacent tubes.

This finding was the subject of Licensee Event Report (LER) Number 2001-003-00 (Reference 14) and NRC Information Notice 2002-02 (Reference 24). As part of the investigation and corrective actions for this finding 647 previously plugged tubes were examined in OTSG-A, and 223 previously plugged tubes were examined in OTSG-B.

IL METHODS A.

DATA ACQUISITION The Eddy Current (ECT) Examinations were performed using the Zetec Miz-30 Digital Multi-Frequency Eddy Current System with Eddynet 98 Software. The data was directly recorded to hard disks located on site and then spooled to the remote analysis locations for primary and secondary analysis.

The ECT raw data and analysis results were then transferred to optical disks for site storage.

Data acquisition was performed remotely using the Framatome "ROGER:' in head manipulators and Zetec Model 1 OD probe pushers. Dual guide tubes were used to the extent practical. Examinations were performed at all four heads in order to support the required examination schedule.

The ECT examinations were performed using a variety of techniques and probes that were tailored to address the specific areas of interest being examined. The teclmiques used for exanmination were based on industry qualified techniques which were site qualified or were plant specific qualified techniques (where industry qualified techniques did not exist or were not applicable). The active and potential damage mechanisms were documented in the "TMI-1 Outage 1R14 Degradation Assessment & Condition Monitoring Checklist, Revision 0". Memorandum TMI-NOB-3, 5973-2001-009 (Reference 16). Table ri-1 provides a listing of the specific Appendix H qualification applicable for each damage mechanism.

Framatome Technologies report 51 5005406-01, "Qualified ET Exam Techniques for Three Mile Island 1R14" (Reference 17) provides further details on site applicability for each examination technique. The examinations were performed under TMI-1 Surveillance Procedure 1300-4B (Reference 4) and Framatome Techmologies Procedure 54-ISI-400-11 (Reference 5) and are further discussed in the following sections.

5

TR-151, Revision 0 TABLE H-1 OUTAGE 1R14 TECHNIQUE QUALIFICATIONS Degradation Basis for Site-Specific Mechanism/

Qualification Data Review Tec,,niue it No..#'s are Performed!

Appendix H Result Documents)

TSP Wear ETSS #96004.1 Yes (Bobbin Probe)

Acceptable (FRA-ANP

()

Document 77 5011531-00)

OD Volumetric IGA Crevice ETSS #96009.1 Yes (LTS Outside Kidney Region)

Acceptable (Bobbin Probe)

ETSS #96011.1 OD Axial IGAJSCC Freespan (Bobbin ETSS #96008.1 Yes Probe)

Acceptable (FRA-ANP Documents 77-5002925-01, 77-1258722-00)

OD Volumetric IGA Freespan ETSS #96008.1 Yes (Bobbin Probe)

Acceptable (FRA-ANP Documents 77-5002925-01, 77-1258722-00)

ID 1GA/SCC Freespan GPU Document Yes And TS Crevice C-1101-224-Acceptable (Bobbin Probe)

E280-072 Impingement ETSS #96002.1 Yes (Bobbin Probe)

Acceptable TSP Wear ETSS #96911.1 Yes

(.115"' MR Pancake Acceptable Rotating Probe)

(1)

PWSCC/ID IGA ETSS #20511.1 Yes (MR Plus Point Acceptable Rotating Probe)

ETSS #20510.1 (2)

ETSS #96703.1 (3)

(FRA-ANP (4)

Document 51-5000345-02)

ODSCC ETSS #20409.1 Yes (MR Plus Point Acceptable Rotating Probe) 6

TR-151, Revision 0 TABLE U-1 OUTAGE 1R14 TECHNIQUE QUALIFICATIONS (Contd)

Degradation Basis for Site-Specific Mechanism]

Qualification Data Review eLIIIIIuuE j

r.., tfUi i e~ti Appendix H Result Documents)

PWSCC ETSS # 96503.1 Yes (115" MR Pancake Acceptable Rotating Probe)

ODSCC ETSS #96401.1 Yes

(.115" MR Pancake Acceptable Rotating Probe)

Explosive Plug PWSCC (.080" MR ETSS #96501 Yes Pancake (5)

Acceptable Rotating Probe)

Sleeve ETSS #96912.2 Yes (LF Plus Point Acceptable Rotating Probe)

(FRA-ANP Document 77-5001580-00)

(FRA-ANP Document 1241690)

Sleeve (Bobbin)

ETSS #96008.1 Yes Acceptable

1.

The EPRI Appendix H bobbin technique is qualified for depth sizing; however, that method is not presently used in OTSG's. TSP wear depth sizing is based on rotating probe data or on the bobbin coil probe data.

Reference 20 provides guidance for each technique when to be used for determining depth measurement. See Reference 21 for additional information on bobbin coil examination for TSP wear.

2.

This technique is qualified for sizing by length or depth percent through-wall of circumferential PWSCC at expansion transitions.

3.

This technique is qualified for sizing by length or depth percent through-wall of axial PWSCC at dents.

4.

This document provides the results of studies performed for TMI-1 to determine the expected depth and length sizing errors expected for various rotating coil eddy current probe examination teclmiques. As a result of this study. TMI has chosen to use the mid-frequency plus point coil for depth sizing ID IGA/SCC and length sizing crack-like indications. The 0.080" high frequency pancake coil was chosen to provide axial and circumferential length dimension for ID IGA volumetric indications. Based on this report., TMVII has chosen to assign a potential 32.6% TW undermeasurement to percent through-wall measurements made on ID indications with the plus point coil in the kinetically expanded region (an indication measured as >67% TW is considered 100% TW for flaw leakage evaluation). The study also concluded that axial and circumferential length measurements are expected to be conservative (i.e.., measured length is greater than actual flaw length) for both crack-like and ID volumetric indications. Pulled tube exams for the 12R outage confirmed that length measurements are conservative for the ID volumetric indications.

5.

This examination technique has been retired by EPRI. It is used for exaunination of the active explosive plugs (85 total remaining at TMI-1). The qualification for this technique is considered valid because the qualification was simply retired by EPRI because of perceived lack of industry use and not because of poor flaw detection capabilirv.

7 Notes:

TR-15 1, Revision 0 A. I Tube Bobbin Coil Examinations The general examination of tubing material was performed from the inside diameter of the tube using a bobbin coil probe. This probe is the most durable and efficient probe available and, when used with tie proper ECT instnrwentation. allows a,--t,,

speeeds v-I 4 inches per second. Exarru en.as--At s inh excess o401 ahsprecn.E minations were performed with a probe speed that did not exceed 40", per second. The data from this probe was used to detect tube wall degradation from such mechanisms as Intergranular Attack (IGA), Intergranular Stress Corrosion Cracking (IGSCC) tube-wto-tube support plate wear, and impingent.

The data acquired was also used to assure all tube support plates were present at their expected locations. All bobbin coil examinations were full length unless otherwise noted. For the purpose of this report, a full-length bobbin coil examination is from the kinetic expansion transition in the upper tubesheet to the roll expansion transition in the lower tubesheet. The 0.540" diameter probe was used to examine tubes with previously identified bobbin coil ID indications while the 0.510" probe was used for initial examination of all other tubes. A 0.480" diameter bobbin coil probe was used to examine the region of three tubes that would not pass a 0.5 10" diameter bobbin coil probe.

Tubes with indications of suspected degradation found during the bobbin coil examinations were re-examined using an MRPC probe.

A.2 Sleeve Bobbin Coil Examinations The unexpanded sections of sleeves were examined with a.400" bobbin coil probe to detect degradation mechanisms such as OD IGA, OD IGSCC, or tube-to-tube support plate wear. This probe was used for these examinations because of its durability and higher examination speed. The examinations were performed at a speed less than 12" per second because of the probe's tight fit in the sleeves.

A.3 Motorized Rotating Pancake Coil (MNRPC) Tube Examinations IMRPC examinations of tubes were performed as diagnostic examinations following bobbin coil examinations or for detection of specific degradation in areas where higher sensitivity and additional information were desired (e.g. kinetic expansions, lower tubesheet crevice, dented regions, and shop re-rolled tubes).

The MRPC probe examinations were typically limited to specific lengths of tubes.

A.4 Plus Point Examination of Sleeves All of the TMI-l sleeves are 80" long Inconel 690 sleeves that are installed at the upper end of the parent tube.

The expansions (including expansion transitions) of sleeves were examined using a Plus Point rotating probe.

The examinations were generally performed from approximately 3 inches below the lower sleeve end to the 15th tube support plate (which includes the two lower expansions) and an area in the upper tubesheet which included the upper expansion. This techmique is required for examination of the parent tube below the lower sleeve end, the lower sleeve end, and roll expansion regions only: however, all acquired data was evaluated by the data analysts. See Figure II-1 for TMI-I's sleeve configuration.

A.5 B&W Rolled Plug ECT Examinations B&W rolled plugs were examined using a rotating pancake coil probe. The examinations were performed on the "'push" or the "pull" and data was recorded as the probe was being inserted or retracted at 0.1 inches per second.

The examinations were performed primarily to detect primary water stress corrosion cracking (PWSCC) in the roll transition regions. This cracking has typically been identified as axially oriented in the toe region, and circunmferentially-oriented or axially-oriented in the heel region.

8

TR-151, Revision 0 A.6 Explosively Welded Plug ECT Examinations B&W explosively welded plugs were also examined using an MIRPC probe. The examinations were performed on the "push" or the "pull" and data was recorded as the probe was being inserted or retracted at 0.1 inches per second. These examinations were performed primarily to detect PWSCC in the expanded regions and tapered portion of the p hased on at oher this crackg is X.pe..e.

,Co axia-lly on A.7 Westinghouse Rolled Plug ECT Examinations Westinghouse rolled plugs were examined using a rotating Plus Point probe. The examinations were performed on the "push" or the "pull" and data was recorded as the probe was being inserted or retracted at 0.1 inches per second. The examinations were performed primarily to detect PWSCC in the roll transition regions.

B.

DATA ANALYSIS PROCESS Eddy current data analysis was performed using Exelon Procedure ER-AP-33 5-040, Revision 0 (Reference 8) and Exelon T&RM ER-TM-335-1005, Revision 0 (Reference 20).

These documents are based on the recommendations of the EPRI PWR Steam Generator Inspection Guidelines (Reference 9) and also meet the requirements of the TMI-1 Technical Specifications (Reference 1) and the ASME Boiler and Pressure Vessel Code (Reference 10).

B. I Data Analyst Qualifications The data analysis process was performed by Framatome ANP (FRA-ANP) and Duke Engineering and Services (DE & S) using personnel quahfied and certified to at least Level IIA in accordance with the employers' approved QAlTraming programs. In addition, these personnel were recognized as Qualified Data Analysts (QDA) as defined in the EPRI PWR Steam Generator Inspection Guidelines, Appendix G. As a supplement to these qualifications, all data analyst personnel received site-specific indoctrination and training. The program included both classroom lectures and "hands on" practice, using eddy current data and experience from TMI and other B&W-designed plants.

The training covered generic OTSG degradation mechanisms and examination methods, and specifically addressed the bobbin coil and rotating probe methods used at TMI.

The total site-specific indoctrination/exanmination process encompassed approximately 36 working hours per analyst and was conducted by a TMI-1 Authorized Level III Analyst. At the completion of the indoctrination each data analyst was required to pass a performance demonstration prior to analyzing bobbin coil or rotating probe data for detection of flaws.

The test was generated by the EPRI Site Specific Performance Demonstration (SSPD) program or, for methods that are not supported by the EPRI SSPD program, a pre designed test.

B.2 Data Analysis Sequence The data analysis process was perfonned in accordance with the same procedures referenced in the above section on data analyst indoctrination and training. The process was performed in four (4) steps with at least two (2) separate data analysts evaluating the data from each examination. The data analysis process included:

1.

Primary Analysis: The primary analysis included an evaluation of the ECT data and the recording of attributes identified in Appendix I over the full length of the exam. As stated previously, for bobbin coil examination of tubes. full length is the unexpanded portion of tube from the lower tubesheet roll expansion transition to the upper tubesheet kinetic expansion transition. For MiRPC examinations of the upper tubesheet expansion transitions and kinetic expansions. full length included the examined region of unexpanded tubing, the expansion transition, and a pre-defined length of expanded tube above the transition. The pre-defined length was displayed to the analyst and was based on required expansion leng-th as defined in the plant's kinetic expansion acceptance criteria. If indications were recorded in the transition or expanded region of the kinetic expansions, an additional 2.0" of expanded 9

TR-151, Revision 0 region was evaluated. Some tubes required evaluation beyond the minimum required length plus 2.0" to determine the acceptabilit, of the expansion for continued service.

In these cases the analyst recorded the actual expanded region examination length as part of the reported results.

For rotating probes. such as MRPC. the analysis included evaluation of the required examination area using strip Chart"t d":--';Z

-us-- d isou a

~ ai ay;, ls dju isplays, *-i*, terrain pluts. The analvsis also included recording the phase angle, percent through wall, voltage, circumferential extent. axial extent, indication code, and/or location of any indications in expanded or unexpanded tubing as required by References 8 and

20.
2.

Secondary Analysis: This analysis was performed in the same manner as the primary analysis described above. The secondary analysis was performed by a different QDA than the QDA that performed the primary analysis.

3.

Resolution Analysis: The results of both the primary and secondary analyses were reviewed by designated resolution analyst(s). This review combined the primary and secondary analyses results, resolved any discrepancies, and assigned final dimensions to any indications requiting length. width, and/or depth sizing. For this outage personnel qualified to Level III QDA performed this function. In the case of indications which were initially reported as exceeding the repair criteria by any analyst, but resolved as not requiring repair, a Level III QDA from both FRA-ANP and DE & S were required to concur that the indication did not exceed the repair criteria.

4.

Designated ODA: A designated QDA reviewed the resolution analysis results. This review included reviewing all repairable indications overruled by resolution analysis, reviewing a sample of indications recorded during the analysis process, and reviewing indications as requested for reconsideration (by any primary or secondary analyst who may have disagreed with, or questioned, a resolution analysis evaluation).

B.3 Data Analysis Software The data for examinations was evaluated using Zetec Eddynet 98 Analysis software, Version 2.20.

B.4 Recording of Indications Eddy current indications were recorded to permit dispositioning the examination results and to facilitate monitoring the tubes during future examinations.

The recorded indications fall into two basic groups, "indications from Tube Wall Degradation" (e.g., indications assigned a "VOL" code or "I" code); and "indications from Possible Damage Precursors" (e.g., indications assigned other three letter codes such as "DNT"). The specific criteria used to record the indications were dependent upon the type of probe being used. A complete list of abbreviations and definitions used to classify, indications is included as Appendix I to this report.

Indications from Tube Wall Degradation Generally indications of tube wall degradation were initially recorded during the primary and secondary analysis of the bobbin coil data. Some indications were assigned a "percent through wall" value based on the phase angle of the indications (if they were ID-initiated by bobbin coil examination) or based on flaw amplitude (if they were unchanged and previously dispositioned as tube-to-tube support plate wear that had not changed).

When the indication could not be accurately assigned a through wall value using bobbin coil examination data, it was assigned a three letter code such as BVC, ADI. or NQI to indicate the presence of a possible flaw. In these cases. the indication's location-amplitude, signal phase angle and three-letter code were recorded to permit further evaluation of the tube.

Once the initial screening of bobbin coil indications was completed, supplemental examninations wxere performed using rotating coil probes (generally 3-coil MNRPC with +Point coil. 0. 115" pancake coil. and 0.080"'

10

TR-151, Revision 0 shielded high frequency pancake coil).

The data from the rotating probe examinations was analyzed and indications were recorded using three letter codes to indicate the morphology of degradation and." in some cases, a percent through wall was assigned. hi general, indications were recorded as SAL, MAI, SCI, MCI, SVI, MVI, or VOL. These codes indicate whether the indication is single (S) or multiple (M), circumferential (C) or axial (A). and whether or not a volumetric (V) condition is present. The "VOL" code signified that -an

.vya....

insiucdujariete u.....

-:*n nature. Like.

the bobb ii..... ii.- lcatiu U

U-were recorded along with the location, amplitude, and phase angle of the signal. Additional line entries were also included for some MRPC indications to record indication circumnferential extent and axial extent.

An exception to the above procedure occurred when an MRPC examination was pre-scheduled for a specific region such as the kinetic expansion region. In this case only the MRPC data was used for dispositioning the tube. (The bobbin coil is not used in the expanded region.) The actual analysis process was performed in the same manner as described above.

Indications from Possible Damage Precursors The analysis of eddy current data may also identify indications that are not specifically attributed to tube wall degradation. These indications may be the result of irregularities in the tube wall profile (IDC), changes in the magnetic permeability (PVN), denting (DNT), or other changes in the electrical impedance of the tube not related to tube wall degradation. All recorded bobbin coil probe "IDC" and "PVN" indications were examined with an MRPC probe.

Approximately 33% of the dent indications located above the lower tubesheet, 100% of the upper tubesheet secondary face dents, and dents >16 volts by bobbin coil probe at the lower tubesheet secondary face or below and not inside the defined kidney region, were examined with an MRPC probe. Dents inside the lower tubesheet defined kidney region were examined with an MRPC probe as part of the kidney region exanmination sample.

Indication Locations The locations of the ECT indications were recorded to identify their "elevation" or "axial location" in the OTSG tubes.

For free span indications, the locations were generally recorded in inches above "+" the tubesheet surfaces or tube support plate centers. For indications located within or adjacent to the tube support plates, the indications are recorded as "+" or "-" from the tube support plate center. The relative location of the tubesheets and tube support plates is shown in Figure 11-2.

B.5 Data Management Two separate data management systems were used to assure indications were documented and dispositioned appropriately. The examination results were obtained from the Eddynet report files and loaded into the data management systems used during the outage. The FTI FDMS and Zetec Data Management Systems were used independently to track eddy current examination results. Final results reports from the two systems were then compared to address any, inconsistencies between the two systems. The overall generator examination was considered completed when both systems produced the same results and indicated that the required examinations were complete. After completion of the lR14 Outage the FDMS System results were used to load data into the TMI-I data management system.

C.

DISPOSITION OF RESULTS C. I Inside Diameter IGA Inside diameter (ID) IGA eddy current indications in unexpanded tubing were dispositioned in accordance with the TMI-1 Tectmical Specifications (License Amendment No. 237). In accordance with the amendment. all ID IGA indications that were detected during the bobbin coil eddy current examinations were subsequently 11

TR-151, Revision 0 examined with MRPC probes. The length and width of the indications (as discerned by MRPC extent calls) were compared to the repair limits stipulated in the Technical Specification.

In addition, the MIPRPC examinations were used to conlirm that the indications were volumetric in morphology (in order to prevent crack-like indications from remaining in service.)

The surface of origin (i.e. inside surface) was also confirmed for all ID IGA indications. ID IGA indications with sufficient bobbin coil signal-to-noise ratio and

bobbin,

.*i"tage were also g-.en a per.cent "u-...

I e

U"- on W -'"V uidniaete bobbia coil piuloc phase angle analysis.

TDlIG* A indctio"nsin un

,expanded tu1bing >4j/ through wall, or of axial and circumferentital extent >0.25" or

>0.52". respectively, were removed from service by plugging in accordance with the Technical Specifications.

In addition, the remaining ID IGA indications were verified for serviceability by in-situ pressure testing selected tubes [See Sections II.D and III.C of this report] and a growth evaluation, in accordance with the Technical Specification. [See Section III.B. 1]

Appendix HI provides a list of tubes, sleeves, and plugs containing indications as a result of eddy current examinations. The 3-letter code "VOL" was used to delineate ID IGA indications in tubing. [Note that some of the indications listed in the Appendix were removed from service as a result of the tube plugging. The data for tubes plugged due to eddy current indications has been identified by use of bold print.] At the end of the 1R14 Outage 992 recorded IM IGA indications in 554 OTSG "A" tubes, and 49 recorded ID IGA indications in 33 OTSG "B" tubes, remain in service in the TMI-1 generators. These indications are located below the kinetically expanded region (below ETL+0.0 inches).

The ETL (Expansion Transition Location) is the location in the upper tubesheet where the tube changes in diameter from fully expanded tubing to the expansion transition).

C.2 Kinetic Expansion Region TMI-I 's OTSG tubes have 17" or 22" long kinetic expansions within the generators' upper tubesheets. During the 1R14 Outage, approximately 38.9% of the unsleeved/unplugged tubes with 17" kinetic expansions and approximately 20.4% of the unsleeved/unplugged tubes with 22" kinetic expansions were inspected with a rotating probe (i.e. MIRPC). The Outage 1R14 samples included all tubes identified as "Potential Leakage Contributors" during Outage 13R.

Analysis Process Each tube examined with the rotating probe in the kinetic expansion region was analyzed to determine if the tube was a structural and/or leakage concern. There are many factors which were used in addressing the structural and leakage issues associated with any indication that was found. These are:

I) the axial and/or circum-ferential extent of the indication.

2) the estimated depth of the indication,
3) the proximity and type of other indications in the expansion,.
4) the radial distance of the tube from the center of the tube bundle.
5) whether the kinetic expansion was 17" or 22" in length. and
6) the nminimum required axial kinetic expansion length (AKELU) to ensure structural integrity in the event of a MSLB.

The mininmumn required axial kinetic expansion length (AKEL1,13 is based on the radial distance of the tube from the center of the tube bundle and also on whether the tube has a 17-inch or a 22-inch expansion.

The determination of the structural adequacy of the tube was based on the measured axial and circumferential extents of the indications.

The volumetric indications had both axial and circumferential measurements 12

TR-151, Revision 0 assigned and were consenratively treated as separate axial and circumferential crack-like indications.

Some tubes had multiple indications in the kinetic expansion region. For tubes with multiple circumferential and/or volumetric indications, the circumferential extents were combined if the indications were located within 1.00" axially of one another. For tubes with multiple axial and/or volumetric indications, the axial extents

-e.c,

=

ibit,

.ad u 0en compard ti?

r l

m the structuial.,

to dter-i-%e....-

0.....,.Woe.

The leakage calculations were based on the estimated depth of the flaws, the axial and circumferential extents of the flaws. and the radial is*t-ncc of t., tUb f ro the center of the bundle. An indication was considered to be a leakage contributor only if its estimated depth was >67 percent through wall, as estimated by a plus point probe, and it was located within a certain distance above the Expansion Transition Location (ETL). This distance was based on the AKEL,,J, value as well as the number of flaws and the axial extent of these flaws in the kinetic expansion. If a flaw between ETL + 0" and ETL + 0.25" was detem~ined to be a leakage contributor, then freespan leakage values were used. For the 17" expansions, if a flaw above ETL + 0.25" was determined to be a leakage contributor, then a leakage reduction factor of 25 was applied to the freespan leakage value, (i.e., the freespan leakage values were divided by 25 to obtain the estimated leak rate.) This leakage reduction factor corrects the leakage to account for the reduction in leak rate provided by the presence of the tubesheet. The axial location at which the leakage reduction factor could be applied to flaws in 22" expansions was a function of the radial location of the tube in the tubesheet and the axial location of the indication within the expansion.

The derivation of this kinetic expansion indication evaluation was provided to the NRC in Reference 13. NRC questions on this submittal were responded to in a GPU Nuclear letter to the NRC (Reference 18).

C.3 Other Indications All crack-like indications detected in the freespan, detected in the expansion transition, detected in the first 0.50" of expanded tubing in the upper tubesheet of the 17" kinetic expansions, or the first 5" of expanded tubing in the upper tubesheet of the 22" kinetic expansions were removed from service.

Tube-to-tube support plate wear indications were dispositioned by evaluating their through-wall extent using an Appendix H-qualified technique. There were no tube-to-tube support plate wear marks >40% through wall detected during Outage 1R14.

All manufacturing/burnish mark (MBM) eddy current calls were reviewed from a historical basis before dispositioning.

TMI-1 did not have qualified techniques for evaluating the through wall extent of OD-surface initiating degradation indications other than tube-to-tube support plate wear. Thus, OD indications resulting from tube wall degradation other than tube-to-tube support plate wear (e.g. OD "groov'e IGA. OD volumetric IGA) were "plugged on detection".

D.

IN-SITU PRESSURE TESTING D. 1 Pressure Test Process In-situ pressure testing was conducted during the 1R14 Outage to assess the ability of the flaws to withstand a postulated main steam line break (MSLB) event on the last day of the just-completed operating cycle. In addition. in situ testing was perfonned on a large sample of voluhmetric ID IGA flaws in order to assess this flaw population in accordance with the Teclmical Specifications. The tubing was subjected to differential pressure equivalent to normal operating, main steam line break, and Regulator. Guide 1.121 (Reference 11) prescribed differential pressures.

13

TR-151, Revision 0 The testing was conducted using localized area hydraulic pressure tooling to pressurize a specific tube region.

The localized testing is performed through a chamber created by two independent probes that lock into the tube and seal from opposite directions.

All tubes that wr hi situ pressure tested were subscquently plugged.

D.2 Candidate Selection The eddy current test results were reviewed to select flaws for in situ pressure testing from a leakage and structural integrity perspective. To avoid complete reliance on depth sizing by bobbin and MRPC eddy current, other parameters such as voltage response and axial and circumferential lengths were also considered to select flaws for in situ testing.

The EPRI In Situ Guidelines (Reference 19) were used to determine which tubes required in situ pressure or leak testing. The EPRI Guidelines use sequential screening criteria. Sequential screening means that only indications which exceed a threshold value for the first screening parameter are evaluated against the second screening parameter threshold, and only indications that exceed the thresholds for the first two screening parameters are evaluated against the third screening parameter, and so on.

Tables 11-2 and 11-3 show the indications that were selected for in situ testing and the results of the tests. There were a total of 21 tubes with flaws that were in situ tested (9 in SGA and 12 in SGB) plus tube B65-130 was pressure tested under laboratory conditions (See Table 11-4) and is further discussed in Section III.B.5. It should be noted that the majority of these tubes did not require testing under the EPRI guidelines and that all tubes screened as requiring pressure testing were pressure tested. Seven of the 21 tubes in situ pressure tested contained indications that exceeded the EPRI screening criteria. The 14 additional tubes were tested to provide a tested population of ID IGA volumetric indications in accordance with the Technical Specifications and its referenced documents (References 1 and 22), or to provide additional assurance that sufficient flaws were tested. The indications that were tested can be divided into five basic categories as follows:

OD Axial Indications Two tubes with axial indications indicative of OD "Groove" IGA were in situ pressure tested (398-1 and B119-2). Both of these tubes had multiple indications located in upper freespan regions. One additional tube (B133-1) had two signals detected at the 12th support plate from the Plus Point inspection. Although the indications in B133-1 were not likely due to tube wall degradation the signals were dispositioned as axial indications as a conservative measure. The +Point coil through wall estimates of tube B133-1 indications were relatively deep, so this tube was pressure tested.Section III.B. 1 provides additional information about tube B133-1.

ID Circumrferential Indications A total of six tubes with ID circumferential indications were in situ pressure tested (3 in SGA and 3 in SGB).

Since all of these flaws were confined within the upper tubesheet. these tests were basically for leakage purposes only.

14

TR-15 1, Revision 0 Mechanical Wear Damage Related to Severed Tube Four tubes were identified in SGB to have wear indications related to severed tube B66-130. Tube B66-130 was severed at the upper tubesheet of the secondary face and had subsequently impacted four adjacent tubes.

Three of these adjacent tubes were in situ pressure tested (B65-129, B66-131, and B67-130). The fourth tube was harvested from theseconda,. side and wa. teted in a laboratory enviroment"(Scc Table 11-4 ad Section III.B.5).

OD Volumetric Indication Tube 59-72 in SGA was in situ pressure tested due to an OD volumetric indication that exceeded the depth threshold for pressure testing.

ID Volumetric Indications Eight tubes were in situ tested due to ID volumetric indications. These tests were performed in accordance with the Management Program for the ID IGA degradation (Reference 22) as referenced in the Technical Specifications. These eight tubes contained 68 volumetric ID IGA indications. One other ID IGA indication was also tested in tube B149-1 although this was not the reason for testing this tube, therefore a total of 69 ID IGA indications were tested. (This tube was tested due to an ID circumferential indication at the kinetic expansion transition.) The main criterion that was used for selecting these tubes was the axial extent of the volumetric indications. The circumferential extents and voltages were also considered in some cases. Two tubes in SGB (B44-75 and B143-43) were selected solely based on the large quantity of indications within the tube. None of the indications in these two tubes required plugging. Based on the large number of indications, however, these two tubes were in situ pressure tested and were subsequently plugged.

15

TR-151, Revision 0 Table H1-2 In Situ Test List and Results: OTSG-A S.

TUBE AND EDDY CURRENT INFORMATION I

IN-SITU TEST RESULTS I

REGION TUBE INURMATION IPLUS POINT DATA BOBBIN DATA GPM G

GPM @

GPM I GPM Q MAXIMUM EXP I ROWI COL LOCATION AX LEN CiLEN VOLTS EST% ORIENTATION IND VOLTS EST%

COMMENTSI NOP MSLE 3NODP 6450psi PRESSURE (Inch)

Fre-pan 59 72 07S

+13.67 0.10 0.10 0.13 156 Nolume ic NI 0.22 58 ODIGA/SCC I 0 0

4 Upper TS 53 485 ETL

-1.43, 0.17 3.14 9 7 0 iCirc.

NDD11 IDGScCC1 0

0 0

0.014 6450 17 Upper TS 121 89 ETL

-0.14 0.60 0.83 86 ID Circ.

NDD ID IGA/SCC 0

0 0

0 6450 17 13S

-18.12 0.14 0.12 0.18 NOD 0

0 0

4394 13S

-16.64 0.19 0.16 0.30 NOD 0

0 0

4394 13S

-15.26 0.13 0.11 0.11 INR 0.44 0

0 0

4394 13S

-8.75 0.24 0.16 0.20 NDD 0

0 0

4394 13S

-7.37 0.19 0.22 0.30 NDO 0

0 0

4394 13S

-4.87 0.39 0.22 0.19 NOD 0

0 0

4394 Freespan 2

25 13S

-1.26 0.29 0.22 0.52 IDVolumetic NDD ID IGAISCC 0

0 0

4394 17 13S

+5.14 0.15 0.16 0.34 NDD 0

0 0

4394 13S

+10.01 0.29 0.22 0.39 IDI 0.47 20 0

0 0

4394 13S

+10.82 0.34 0.22 0.38 IDI 0.47 23 0

0 0

4394 13S

+11.17 0.24 0.22 0.40 NDD 0

0 0

4394 13S

+14.08 0.24 0.16 0.15 INR 0.25 0

0 0

4394 13S

+14.40 0.24 0.16 0.31 NOD 0

0 0

4394 14-S

-2.85 0.18 0.18 0.15 BVC 0.38 0

0 0

4400 14S

-2.20 0.13 0.12 0.14 ID1 0.39 17 0

0 0

4400 14S

-0.24 0.13 0.12 0.10 NOD 0

0 0

4400 14S

+2.42 0.13 0.17 0.23 IDI 0.45 23 0

0 0

4400 15S

+11.89 0.27 0.17 0.31 IDI 0.45 17 0

0 0

4400 ISS

+16.70 0.13 0.12 0.20 INR 0.38 0

0 0

4400 15S

+17.82 0.13 0.17 0.31 INR 0.40 0

0 0

4400 Freespan 135 2

15S

+19.39 0.13 017 0-38 IDVolumetric INR 0.30 ID IGAISCC 0

0 0

4400 17 15S

+21.94 0.13 0.23 0.34 INR 0.51 0

0 0

4400 15S

+24.78 0.09 012 0.35 NOD 0

0 0

4400 UTS

-17.24 009 0.11 0.33 NDD 0

0 0

4400 UTS

-13.39 0.09 0.12 0.23 INR 0.30 0

D 0

4400 UTS

-11.75 0.13 0.12 0.22

_NOD 0

0 0

4400 UTS

-10.63 0.18 017 0.42 0DI 0.58 30 0

0 0

4400 UTS

-9.66 0.09 0.12 0.21 NOD 0

0 0

4400 07S

-9.54 0.40 0.17 0.14 IDI 0.54 17 0

0 0

4403 Freespan 112 85 07S

-7.93 0.27 0.12 0.18 ID Volumetric NOD 10 IGAISCC 0

0 0

4403 17 15S

+16.18 0.13 0.17 0.19 BvC 0.23 0

0 0

4403 12S

+7.70 0.16 0.15 0.22 NOD 0

0 0

4400 12S

+9.92 0.11 0.15 0.25 NOD 0

0 0

4400 12S

+11.56 0.11 0.15 0.43 NOD 0

0 0

4400 Freespan 95 127 12S

+13.19 0.32 0.25 0.36 IDVolumetric BVC 0-26 IDIGAISCC 0

0 0

4400 17 13S

-11.87 011 0.15 0+18 BVC 0.30 0

0 0

4400 13S

-11.41 0.11 0.15 0.37 NDD 0

0 0

4400 15S

+13.52 0.15 0.17 0.40 BVC 0-36 0

0 0

4400 15S

+13.67 0.20 0.17 1.35 NDD 0

0 0

4400 UpperTS 72 124 ETL

-2.46 0.30 0.37 1.48 ID Volumetric NOD IDIGANSCC 0

j!

0 4392 17 Upper TS 6

ETL

-0.06 034 0.75 j 71 ID Circ.

NOD IDIGAI.SCCj 0

0 6450 17 16

TR-15 1, Revision 0 Table 11-3 In Situ Test List and Results: OTSG-B

.If ITU TE:iST RESULTS I

REGON-I ATI.O. N I PLUS POINT DATA 6,,ND.TA I e

G-GPMD A

,,UI fRO~~~~ ~~~

CLLOAON LN C1 LE VOLTS 1 EST %ORIENTATIOrIN I VOTS MSLESTPPRSU nh

-O

-CO LOCATI_

NJA j-- IL

__NOVLSE t

To ANISM NOP

-SB 3N0DPIPRESSURE(nh UeETL

.0.27 0.36 0.24 1.08 NOD 0

0 4400 Upper TS 80 ETL.0.36 0.30 019 0.95 ID Volumetric NDD ID IGAISCC 0

nI 4n iin 17 ETL

-0.51 0.36 0.29 0.83 NDD 0

0 0

4400 06S

+6.04 011 0.10 0.29 INR 0.29 0

0 0

4400 06S +18.77 0.11 0.10 0.16 INR 0.28 0

0 0

4400 06S +21.45 0.16 0.10 1.02 NDr 0

0 0

4400 08S +14.76 0.11 0.15 0.17 INR 0.29 0

0 0

4400 Freespan 143 43 09S -13.23 0.16 0.10 0.13 ID Volumetric BVC 0.25 0

0 0

4400 09S

-7.23 0.16 0.15 0.13 BVC 0.31 0

0 0

4400 09S

+1.74 0.10 0.15 0.20 NDD D

0 0 0 4400 10S

+7.91 0.14 0.12 0.38 BVC 0.39 0

0 0

4400 11S

-11.92 0.10 0.10 0.28 BVC 0.32 0

0 0

4400 I

11S

-6.47 0.16 0,15 0.23 BVC 0.32 0

0 0

4400 UTS

-7.05 0.43 0.10 44 NOI 0.11 0

0 0

4400 UTS

-6.19 0.39 0.09 61 NDD 0

0 0

4400 Freespan 98 1

UTS

-5.73 0.34 0.10 49 OD Axial NOI 024 Groove IGA 0

0 0

4400 17 UTS

-4.82 0.16 0.13 52 NQI

.0 0

10 4400 UTS

-4.68 0.21 0.15 51 NQI 0.17 0

0 0

4400 UTS -4.16 0.32 0.17 36 NOD 0

0 0

4400 Freespan 66 131 15S

+45.55 8.30 043 4.87 62 OD VoluNetric NOI 065 81 MechanicalWea 0

0 3.2 4360 17 67 130 15S

+44.85 6.51 0.38 3.69 41 NQI 063 67 Damage 0

0 0

4350 17 reespan 119 2

14S

-5.37 0.35 0.29 38 NQI 0.44 0

0 0

4400 Fresa 11O2D Axial Groove IGA

-17

_ 14S

-4.55 0.74 0.21 40 NDD 0

0 0

4400 Freespan 80 31 UTS

+0.26 0.26 1250 90 ID Circ.

NOI 1.01 ID IGAISCC 0

0 0

4350 17 15S

+1.32 0.21 0.15 0.32 BVC 0.31 0

0 0

4400 15S

-2.59 0.16 0.15 0.17 BVC 0.35 0

0 0

4400 15S -9.71 0.16 0.15 040 IDI 0.44 20 0

0 0

4400 15S

-14.07 0.16 0.15 0.41 NDD 0

0 0

4400 14S

-8.87 0.16 0.15 0.32 IDI 0.46 23 0

0 0

4400 14S +16.12 0.10 0.14 0.30 BVC 0.36 0

0 0

4400 14S

+9.43 0.16 0.15 0.24 IDI 0.47 27 0

0 0

4400 Freespan 44 75 14S

+5.84 0.16 0.15 0.14 ID Volumetric BVC 0.29 ID IGA/SCC 0

0 0

4400 17 14S

-13.47 0.16 0.15 0.21 BVC 0.37 0

0 0

4400 13S +17.34 0.16 015 0.26 NDD 0

0 0

4400 13S +12.36 0.16 0.15 0.29 BVC 0.37 0

0 0

4400 13S

+9.00 0.16 0.13 0.21 IDI 0.35 30 0

0 0

4400 13S

-18.12 0.16 0.20 0.33 11 0.42 27 0

0 0

4400 12S

+12.45 0.16 0.15 0.24 NDD 0

0 0

4400 09S

+10.591 0.16 0.15 0.15 NDD 0

0 0

4400 UpperTS 149 1

ETL

+0.00 0.28 0.88 81 ID Circ NDD ID IGAISCC 0

0 0

6500 ETL

-1.01 0.17 0.13 0.15 ID Volumetric NDD IDIGAJSCC 0

0 0

6500 Freespan 65 129 UTS

-0.60 2.75 0.33 1.24 38 OD Volumetric NQI 0.55 82 Mechanical Wea 0

Iama-e 0

0 0

4350 17 TSP 133 1

12S

+0.88 044I 0.78 I 8 ODAxia ND ndication 0

0 0

4400 17 12S -0.35 0.37 0,91 88 ODAxial NQI 017 43 0

0 0

4400 UpperTS 148 261ETL _+.00 017 1.757 96 IDCiro ID IGA/SCC 0

0 0

I 6450 1-17 17

  • Tube 66-131 in OTSG-B ruptured at 4360 psig. The 3.2 gpm leak rate occurred with a measured pressure at the pump of approx. 450 psig (and a calculated differential pressure at the defect of less than 100 psig).

I t]l*l" /41MI ] I"l II If

[:111*l*l,-lllT II*lll;;i*ll;IUl$*'l'l/"lkl 1

TR-151, R,'

n 0 K

Table 11-4 Laboratory Pressure Test List and Results: OTSG-B TUBE AND EDDY CURRENT INFORMATION PRESSURE TESTI RESULTS GPM GPM GPM GPM MAXIMUMI EXP REGION

'I'IBI INFORMATION PLUS POINT DATA BOBBIN DATA COMMENTS PRESSURE (Inch)

ROW

COI, LOCATION AX Ci VOiLTS EST%

ORIENTATION IND VOLTS EST NOP MSLB 3NOD 6450 LEN LEN psi Freespan 65 130 15S +45.37 6.34 0.44 5.84 92 OD Volumetric NQI 11.44 99 Mechanical Wear 0

4.88*

2979 17 Damage

  • - This Icakrate was mcasured at with a measured pressure at flhe pump of approx. 900 psig (and a calculated differential pressure at the defect of approximately 100 psig.)

18

TR-151, Revision 0 FIGURE II-I B&W ROLLED SLEEVE Upper Sleeve End (USE)

Upper Sleeve Roll (USR)

Roll (MSR)

Lower Sleeve Roll (LSR)

LOowe Sleeve End (LSE)

LY4.0 1.5 19

TR-151, Revision 0 Figure 11-2 TMI-1 OTSG DESIGN INFORMATION Tube Information Number of Tubes:

Number of Rows:

Max Tubes/Row:

Tube Material:

Nominal OD:

Nominal ID:

Nominal WT:

Minimum WT:

Tube Length:

15,531 132 Inconel 600 0.625 inch 0.551 inch 0.037 inch 0.034 inch 673.375 inch Tube Support Information Number of Tube Support Plates: 15 Tube Support Material:

Carbon Steel Tube Support Thickness:

1.50 inch Tube Supports:

All trefoil broached except the 15"h TSP which is drilled in the periphery Tubesheet Information Tubesheets are carbon steel, 24 inch thick (Primary faces are 5/16" Inconel clad).

Tubes are open crevice with a minimum 1.0 inch long roll in the lower tubesheets. TNI in-service tubes have either 17 inch or 22 inch kinetic expansions in the upper tubesheet.

Sleeve Information Sleeve Material:

Nominal OD:

Nominal ID:

Nominal WT:

Sleeve Length:

Roll Length:

Number of Rolls:

Inconel 690 0.525 inch 0.431 inch 0.047 inch 80 inch 1.50 inch 3 (1 Upper and 2 Lower)

Note-The number between the support plates in the figure at left indicates the distance between tube support plates in inches 20 UTE UTS u1s 08s 07S 06S 05S 04S 03S 02S 01S LTS LTE

TR-151, Revision 0 OUTAGE 1R14 EXAMINATION CATEGORIES AND RESULTS All tubes that were in service during the prior cycle (Cycle 13) were examined with a bobbin coil probe. The kinetic expansion transition and the required length of the kinetically expanded tube above the transition were examined in approximately 39% of the in-service tubes. 870 out of service tubes were examined in order to evaluate the steam generator condition relative Lo failed tube B66-130. Thc cxaminations were performed for three reasons:

S.....~L~a

%,UqUU*A

u. I I ecluinai.SpeciufLation 4.19y
2.

NRC Commitments

3. TMI-1 elective examinations These groups were further divided into specific categories.

This section defines the examination scope, purpose, selection criteria, and examination results by category.

A.

SCOPE SELECTION During Outage 1R14 TMI-1 chose to initially perform bobbin coil examinations on 100% of the in-service tubes in each OTSG. In addition to the bobbin coil examinations, approximately 39% of the tubes in each OTSG were scheduled for MIRPC examination of the kinetic expansion transition and kinetically expanded region. In order to define a kinetic expansion examination results classification, TMI-1 assigned tubes to groups prior to the Outage. Sample expansion, for the kinetic expansion examinations was then based on the results of each examination group. No sample expansion was possible for the bobbin coil examinations since all of the in-service tubes were examined.

Tables III-1 through 111-4 provide the examination categories, quantities, and reasons for examination. Figures III-1 through 111-6 provide tubesheet plots of the kinetic expansion, lower tubesheet., and sleeve examination locations.

TABLE II1-1 BOBBIN COIL TUBE EXAMINATION SCOPE

  • EXAMINATION OTSG-A OTSG-B REASONS FOR SELECTION TECHNIQUE TUBES TUBES EXAMINED EXAMINED 540HF 334 105 These tubes were examined with a 0.540" -- bobbin probe to more accurately evaluate ID-initiated indications observed with bobbin coil probes during Outage 13R. During Outage IR14 tubes with recorded ID indications identified during a 0.510" bobbin examination were also subsequently examined with a 0.540" bobbin probe.

510UL 14530 15272 These are the remaining in-service tubes that were not initially examined with the 0.540" diameter bobbin coil probe. This examination quantity includes examination of 647 previously plugged tubes in OTSG-A and 223 previously plugged tubes in OTSG-B.

48OUL 1

2 These are tubes that would not pass a 0.5 10- bobbin coil probe.

400SB 1

0 This examination was performed on a previously plugged tube to determine the location of an obstruction.

  • Note: Some tubes were examined with more than one bobbin probe examination teclhique. Therefore. the sum of the tubes examined in the above table does not equal the total number of tubes examined.

21 III.

TR-151, Revision 0 TABLE 111-2 MRPC TUBE EXAMINATIONS EXAAvIiNATiION OTSG-A OTSG-B REASONS FOR SELECTION TECHNIQUE TUBES TUBES EXAMINED EXAMINED 520H1F 5157 5981 These are kinetic expansion examinations of unsleeved tubes in (Kinetic service. The examination scope included all in-service un-sleeved Expansions) tubes not examined during Outages 12R or 13RP, tubes with potential leakage contributing flaws identified during Outage 13R, tubes with "crack-like" indications identified during Outage 13R, and all in-service kinetic expansions in 22" expansions that are located at a tube bundle radial location of <47.00" or less 520HF 633 830 Approximately 33% of the tubes in the lower tubesheet "kidney" 460BF region were examined with the MRPC probe. This sample also (Lower exceeded 3% of the total number of tubes in each OTSG. The Tubesheet kidney region generally included areas on the tubesheet array that Examinations) were identified to have lower tubesheet secondary face dents during Outage 13R. Figures 111-5 and 111-6 provide tubesheet maps of Outage 1R14 tubes examined with MRPC probes in the lower tubesheet. The examination in the kidney region included an axial length from 12 inches below the secondary face of the lower tubesheet to 4 inches above the secondary face in 625 tubes in OTSG-A and 827 tubes in OTSG-B. The other tubes were examined because of shop post stress relief roll expansions, minor tube end repairs, or specific dents located outside the defined kidney region.

5201F 1055 727 These examinations were performed on specific areas of a tube to 520MB further evaluate indications identified by bobbin examinations or Special Interest as an Outage 1R14 Technical Specification-required examination due to Outage 13R examination results. The sample included those tubes where ID IGA indications >0.13 inches axial length or

>0.26 inches circumferential length and located below the kinetic expansion were left in service following the 13R Outage. These examinations also included:

all indications of possible tube wall degradation, all PVN indications, and all IDC indications 33% of all bobbin coil dents above the lower tubesheet secondary face all upper tubesheet secondary face dents all bobbin coil dents >16 volts located at the lower tubesheet secondary. face or below and located outside the defined kidney region (approximately 33% of the defined kidney region dents were examined as part of the lower tubesheet examination scope) 52011F 82 86 In-senrice non-sleeved tubes adjacent sleeved tubes were (Sleeve Border) examined at the 15S tube support plate and upper tubesheet secondary face to identify-any possible high cycle fatigue precursors.

520HF 289 129 A sample of tubes deplugged was examined at the 15S tube (Deplugged support plate and upper tubesheet secondary face in order to Tubes) detect possible circunmferential cracking.

22

TR-151, Revision 0 EXAMINATION OTSG-A OTSG-B REASONS FOR SELECTION TECHNIQUE TUBES TUBES EXAMINED EXAMINED 520PI 9

I1 These are tubes that were examined after compiction of in situ (Post In Situ pressure testing. Twelve tubes in OTSG-B were in situ pressure Pressure T esting) tested. Tube B66-131 was not examined after in situ pressure testing because it failed the in situ pressure testing.

TABLE 111-3 SLEEVE EXAMINATIONS DATA SET OTSG-A OTSG-B REASONS FOR SELECTION TUBES TUBES EXAMINED EXAMINED 400SB 83 85 The unexpanded region of sleeves was examined with this probe (Sleeve to detect any general degradation such as OD IGA or wear. This Bobbin) group included approximately 33% of the installed sleeves in each OTSG.

400PP 83 85 Approximately 3 inches of parent tube below the lower sleeve (Sleeve +-

end, the lower sleeve end, and all three roll expansions (including Point) transitions) were examined with this technique because of the higher sensitivity to degradation at these locations. This group included approximately 33% of the installed sleeves in each OTSG.

23

TR-151, Revision 0 TABLE HI-4 PLUG EXAMLNATIONS DATA SET OTSG-A OTSG-B REASONS FOR SELECTION PLUGS PLUGS EXAMINED EXAMINED 525EP 21 8

This examination scope included approximately 33% of the in (Lower service lower tubesheet explosive plugs.

Tubesheet Explosive Plugs) 460PP 134 80 This examination scope included approximately 33% of the (Upper installed upper tubesheet Westinghouse rolled plugs including all Tubesheet in-service upper tubesheet plugs of this design that were not Westinghouse previously examined with eddy current.

Rolled Plugs) 410MB 2

0 This examination scope included two B&W Inconel 600 upper (B&W 1-600 tubesheet rolled plugs that were initially scheduled to remain in Upper service after the 1R14 Outage. All other plugs of this design in Tubesheet OTSG-A were scheduled for replacement during the IR14 Rolled Plugs)

Outage. All plugs of this design in OTSG-B were previously replaced.

Visual 1336 404 This was a visual examination of all upper tubesheet in-service Examination plugs installed prior to Outage 1R14.

Lower Head Visual 1399 404 This was a visual examination of all lower tubesheet in-service Examination plugs installed prior to Outage 1R14. The lower tubesheet of Upper Head OTSG-A has 63 "thimble plugs" installed in row 76. These plugs were installed during steam generator fabrication and account for the disparity in the number of plugs examined in the upper tubesheet versus the lower tubesheet in OTSG-A.

24

TR-151, Revision 0 FIGURE III-I OTSG-A KINETIC EXPANSION EXAMINATION LOCATIONS 44**33 -

  • 3.

..4 3-43

÷..

4-.--*.

4~~~~~~

4*33-

-4443-3.*-

.*.. ÷ *. *

.* : g¢*i

.4*.

..*~..............

  • .i*;....:..:'.

-34434444*4*4.

I...

S343-44344444 4443~ ~~.3.4.....

4 3

~

434444

.444 343;:::;"::

34...3 3..43..

4.*.4*... 34*.4*4*44*

.4*4*.4*34 3

3'"443+44443444*4343 343

-4.*4-

-343

  • 4*

'**¥*:**'*

4...

4v4 :...44 -

343.-:

      • .***.**;*`..`*..`*

3 3---.-.---.. *3.

... :-'34.3:..:'..:....:

... 4.:.:..--.. :..34 -.

3

..- : -.- ;.--.:;.4 4-.:...-..

34....

44.

4.4*

  • 4*4*.3444443434.*
  • 44..?4*.4.43.4..4..4.434.4.

3434

  • 4
  • 4 4.

3 i,4 3z 4* 444

+n i.

3 44

-' 344

-3.3 43 34

-3.3--t***

.t...

.**.*.t.,...

  • ,,:,,, **..*-'*'.*÷.*"

";* :, ;: :+

"3.4"-..

343"".'

434-"'..:'"

.4: *"

-4'--. *:::-

3444*~4 343:--:..'.

'4.3**

34-3-*-:*.--';**.*-

34-.443':.

434:

3-

-3.4:3.-

3*.**i*i

÷*.*'4343 3434. 3

-'34~:*i 343-34343.-

3:*:g*

  • .43444 4.:;::;:
    • :i::

÷*

34J

-3

,%44. 4*4444433444.f44.N -

h4,.4443 i.444.44 4

÷444 4.*43i3444 434444 ii3W444**4s/u4444444*t4.4444:3 44 4 4-

"*;; "344.34**44444*444 3

3 *"'

4 3

a;i *+.'

-4÷,4444'*44 44'44.3

.43 44 34*:

.:..:...3.3

.:.....4.e.... :.:.3-...;..:.

44+...

- 34.3....

÷....

4..

4

  • 3444 4444.4343:-

44-3..4-4343:-4.:.--::

4

.44-34

÷.-3-34:.:--:... :.--4.. -..

-444444.4.4-444444fl434 443..4434434

.44.434i4 3*4344444*4 3-"3',i3*ii#ii::.4 34;-.. 444-444443'::"

""*i*44.43-

-4334 34344 -*

.433:3

-4iig4,;'i;,:': *:::.-gi*.

Examination Location 25

UOptoTIq UOr~nluWmxa 4..

4...u..4 4

.. lIU4£444CA.44..4WC.444..A*1444£

    • te4..4.4444 4444e~e4.4.4............
  • e.44
  1. 4.t l

b 4.

444 S *44.

4 A.

t~4,*'~fl,

f.

I4.4

.4 t.t

e.

e 4r...,

  • e 4

4 4 4 4 4 4 fl 4

4.i ~

  • i e 44~....r r..

444.4.,~~~~~

~

e14£4

1.

4t A

e 41e44444e%4.4444 4,

4

  • 4 4 e*

4 44,4 e~~~

4*£ 4A 44 4C44 4

e 44C

  • 4 e~

44 4 ~ 44~.

~

  • 44.4*U
4. 4

.4 40434.

-04e4.44~4444££4C44.4l f4.4.4SI4444 44

-r

+

SNOLLVJO1I NOIIVNIIW'Xa NOJSNVdX¶ D1iIINJ 9-DS+/-O z-II I MNflIJ 0 UIOESTAOYJ '1s1-}JLI

TR-151, Revision 0 FIGURE 111-3 OTSG-A SLEEVE EXWAINATION LOCATIONS

$5 0

e0 0

..-""1

$5.

+......

..+

Plugged tubes

"* Sleeves not examidned

"* Sleeves examined 27

TR-15 1, Revision 0 FIGURE 111-4 OTSG-B SLEEVE EXAMINATION LOCATIONS 4p 4000

  • 0 40 0, 4

4 04W 0,

0 40 04 0*

4 0a00 4@

0 040 e0 :0 0 0.o0o1W

.04 0

+* -Plugged tubes***44*

4 4 0 +

Sleeves.

0 exa 0*+:-

.4*le 4 exa44 4

0 0 4 4 00::.

i -" :

S

~ i 0 4 0 4 @ 4. *.

4-4 4 0

  • 4 4 4-:-.--.-.......*...:...:-.-:-:............-......-. *...

4 0 *

  • *0"

" " "4 ' :4" " : " -

"4". "

4.
4.

...... " ' - 5 ".. '..

S4*

0 0 4 4

? :"

" "5 :. ' ". ' ".. : : : :. : : i : - ' " : : -

  • 4 4 4*

4 4 0

  • 4
  • :." 2 ":.

....i..

- 4*

  • : >.:: -:~:::":::..':.'::"

-"-- :: -. :.:.-.* :;.:.:::.C

  • =ii: * * =i= :=i- *~ **=: * * * * * * * *
  • 0 0

"2 =;

2: 2 =2 =25

. : =2." 2 : =2 2 :.=. :2

  • * * -": i
  • P lu* a g ed: tu b ess
i:
i:.** @ * * @ 4
  • * *.2

. s.i: ::.2 ": :* : : "" -..

O ~*: @,

S le e v e s-n o t e x a m in e d Sleeves examined 28

TR-15 1, Revision 0 FIGURE 111-5 OTSG-A LOWER TTB]ESHEET EXAMINATION LOCATIONS S.,....... ':*.-i.' '...*. :'i.-......-..

  • ;:- : :: : 2:::::.-

. ::;::::.; " :-- ::;-:;::r- --.::::..

?"?.::: ?.::

.:'.:.:2-i ?.2 :.

" :.2.....':£..

."........::t 1".:

"2

... :-.i

?:: :

.:!i.:: :-

..::?*:-.i:; :.

:.. :,i::
; i,. :: :.::*.:.::: ::!: i --:.:::.. :.:::. :::.i::.: i:.

y.

!::i':

2:::i:: !::::::::::::*: : : : ::;:i'

  • ?) ::
' is :
  • g ',: *.g* 2i:i::i :::g ::2 :i:::::".i:::i:: :::::': ::*: :-;:::::

..::.::..; :***.:**t:*.:

    • .*::;:i.:;....; :*;.*.::::::::::::::::::::::::.:@
.*:--:. :. ; x :.i:.*. ':::: :.. ::::.::;.:;::..:"*.*:;'.::

.o ::;::i::,:{:-;'::-;:*-.;:::...- :.i:::;i :-;:,:*..

  • i*
.i ?..*

'÷-.P ;:::: :*::::::i:: * ::W ::I. : --.::. --...

  • ~ ~~~

4xm naia4oalo 29

TR-] 5 1, Revision 0 FIGURE 111-6 OTSG-B LOWER TUBESHEET EXAMINATION LOCATIONS S..

ii.!zS~!

i :!{

~* i::-..

`.:...

..;.*:. v..:.:...:...:....°.:.

4.3 :......

.:. < : ::, :.:.:. ::. : : -, ;. : ::, * -,..:., : : : 3

.."?:':'-'::?'"'::..

========
"* *..-.".T :Y -. '"=============
==============

., :: :i:':.E ::

> :. "-}..::-2 x :.b " i:'!.5 +

.i.-.:.::;.........

i;.: i

...!::.; :i. -:. ' '....
i-, :? : -::1: :i{:?
  • !:*!*:**::**}!**::*;**i:*}+:.*:*

.:~i }** :i**::*:** }::**g;; `* 'g `:`;*4*' *:...:..:

¢ i:t~*}i~*;i

.- N

':.- ::":-::::.:?:S;" :: -"::.:.": 4 :"7.:.-:":-:: '""..:f."--.:",,,

w 4.* -.4 : ii * * ' : :::. ii :':" i :-* ! : '::':{:" ::z?";i } :

~~~

??: "

": if

" i ;

i, g :
  • g :: :

w::

L i:::...

......... i.-.

!i~!.!.i.. * :"

~~~~~~~~~~~~.

!i
      • :: -: ) ! i: :** :: :i,:

tio o..c.........a.......i....o.n........

30

TR-151, Revision 0 B.

EXAMINATION RESULTS B. I Tube Examinations (unexpanded Region)

Appendix II of this report provides a listing of detected indications in tubes, sleeves, and plugs that were in service during Cycle 13.

The examination results were reviewed to determine Technical Specification classification requireccnts pcr Technical Speclifcatiuon 4.19 and to deternine whether other conditions were present which could be indicators of other damage. Volumetric ID IGA indications were evaluated for signs of growth as required by the Plant Technical Specifications and AmerGen Energy Report TM 01-00328 (Reference 22). No secondary side miscellaneous damage such as missing support plates was observed. It should be noted that previously plugged tube B66-130 failed at the upper tubesheet secondary face and caused significant damage to adjacent in-service tubes. The tube B66-130 condition is discussed later in this report.

Since the bobbin inspection sample included 100% of the in-service tubes in each generator, the category classification is for documentation and notification purposes only and could not affect further bobbin coil inspection sample expansion criteria. The three categories are as follows:

C-1 Less than 5% of tubes inspected are degraded and none are defective C-2 One or more but not greater than 1% of tubes inspected are defective or between 5-10% are degraded C-3 More than 10% of tubes inspected are degraded or more than 1% are defective The results of the 1R14 bobbin inspection at TMI-1 are classified as C-2 for each steam generator based on having one or more but not greater than 1% defective tubes. For purposes of this classification, the following limits applied:

A tube was classified as defective, degraded, or imperfection in accordance with the TMI-1 Technical Specifications. Every tube with indications confirmed by MRPC was reviewed and assigned a classification.

For tubes with multiple indications, the tube was classified based on the most limiting indication detected in that tube.

TRENDING OF ID INDICATIONS During the 1R14 inspection, a new Technical Specification Amendment No. 237 (Reference 2) was implemented to address the volumetric ID IGA indications located in the non-expanded sections of tubing. In accordance with the Teclmical Specification, two different statistical tests must be performed on three different eddy current parameters. If all of these tests are passed, then the assumption of no growth is considered valid and can be used in the performance of the operational assessment. If any of these tests are unsuccessful, then a cycle-specific growth model must be developed and used for the operational assessment.

The three eddy current parameters that must be evaluated are the bobbin coil estimated depths, the bobbin coil voltages, and the circumferential extents from the MRPC inspection. The two tests that must be performed are the Sign Test and the Paired t-Test. For each of these tests, the growth is evaluated against a small positive change for the three eddy current paranmeters. (The use of small positive values reduces the possibility that random process error alone could result in mistakenly concluding that actual physical growth has occurred.)

These small positive reference values are lTW estimated bobbin depth. 0.05 bobbin volts, and 0.01 circumferential extent.

In addition to the Sign Test and the Paired t-Test, the Extreme Value Test was used to help identify outliers in the data. The main purpose of this test is to identify indications that: 1) exhibited abnormal growthi during the previous cycle of operation, or 2) may have been mis-analyzed or mis-characterized in either the current or the previous outage.

The results of the Sign Test and the Paired t-Test are shown in Table 111-5. This table shows the results for both steam generators combined. As shown in the table, the Sign Test and the Paired t-Test were passed for all 31

TR-151,, Revision 0 three of the eddy current parameters.

Per Reference 22, the data from both steam generators should be combined prior to performing the tests.

In summary, the statistical values observed for the bobbin coil voltage and through wall measurements of volumetric ID IGA are very much in line with similar evaluations performed for prcvious outages and continue to suppoft a no growtih concIusioni.

32

(r Table 111-5 Summary of ID IGA Growth from 13R to 1R14 Number Combined Bobbin EAt. Depth*

Combined Bobbin Volts*

Combined Circ Extent N uber o f lData Ponts ~* ****

145 292 828 Ad!justed Average Change **

-1.5 %o'TW

-0.046 V

-O.01g in.

Standard Deviation 7.2 %TW 0.058 V 0,039 in.

Maximum Change (Adjusted) **

19 %TW 0.16 V 0.12 in.

Number of Zero or Negative Values 91 245 621 Sign fest Results Critical Value 62 131 389 Paired I-Test Results ****

Adjusted Average Change **

-1.5 %TW

-0.046 V

-0.018 in.

Critical Value 1.0 %TW 0.006 V 0.002 in.

The bobbin growth tests only include those indications which were confirmed with Plus Point and only includes the data from the 5401IF probes from both outages.

The average change and the maximum change shown in the table have already been adjusted downward by a small reference value as provided in the ID IGA Management Program. These adjustments are I T'W, 0.05 volts, and 0.01" circumferential extent.

The Sign 'est is passed if the number of zero or negative values is greater than the critical value.

'lehe Paired t-Test is passed ifthe adjusted average change is less than the critical value.

Bobbin and MItPC indications were considered to be the same if they were less than I" apart axially during the two outages.

33 I Revision 0 l,

TR-151, Revision 0 LEAKAGE CALCULATION FOR VOLUMETRIC ID IGA Reference 22 describes the method for estimating the postulated primary-to-secondary leakage for the ID IGA indications located in the non-expanded regions of the tubing. This process uses a hypergeometric distribution to determine the number of indications that must be assumed to leak. It is based on the total number of indications detected, the number of indications Lhat have been in situ leak testcd. and the number of leaking flaws wit' Lile tested population.

Pr

....... n,, 212, dnctce-n volumetric t'.1.. hdications had been successfully leak tested prior to the 1R4i outage. However, for this analysis, no credit was taken for these previous leak tests. During 1R14,. a total of 69 volumetric ID IGA indications were leak tested (40 in SGA and 29 in SGB). None of the tested indications showed any signs of leakage. Per Reference 22, the in situ tests performed in one steam generator can also be applied to the other steam generator. This is because both of the steam generators share a common primary coolant system, and they were both damaged simultaneously by the sulfur intrusion into the primary system in 1981. Therefore, 69 successful in situ tests will be credited for both steam generators in the leak rate calculation.

To determine the leakage contribution for the volumetric ID IGA indications, each indication is first assigned a leakage value based on its axial extent as shown in Reference 22. Table 111-6 shows the assumed leakage values as a function of the measured axial extent of the volumetric indication. After determining the leak rate for each indication, the average leak rate per indication was calculated by dividing the total leak rate by the number of detected indications in each steam generator.

Using the number of indications detected and the number of in situ tests performed as inputs to the hypergeometric distribution, the number of assumed leaking indications was adjusted until a minimum confidence level of 95% was obtained. This number of assumed leaking indications in each steam generator was then multiplied by the average leak rate for that steam generator to determine the leak rate due to volumetric ID IGA. Table 111-7 provides a summary of the inputs and results of this calculation. As shown in the table, the calculated leak rates for the as found condition of the tubes were small (<0.047 gpm for SGA; and <0.004 gpm for SGB) due to the extensive in situ leak testing, without leakage, that was performed during the 1R14 outage.

34

TR-151, Revision 0 Table 111-6 Predicted MSLB Leak Rate vs. Axial Extent for Volumetric ID IGA Indications Volumetric ID IGA EC Assumed 100%TW Crack Leak Rate @ 600F Axial Extent (in)

Length (in)

(gpM) 0.09 0.03 0.0002 0.12 0.04 0.0004 0.15 0.05 0,0009 0.18 0.06 0.0013 0.21 0.07 0.0020 0.24 0.08 0.0028 0.27 0.09 0.0040 0.30 0.10 0.0054 0.33 0.11 0.0074 0.36 0.12 0.0102 0.39 0.13 0.0139 0.42 0.14 0.0186 0.45 0.15 0.0246 0.48 0.16 0.0323 0.51 0.17 0.0419 0.54 0.18 0.0539 0.57 0.19 0.0688 0.60 0.20 0.0877 0.63 0.21 0.1094 0.66 0.22 0.1368 0.69 0.23 0.1685 0.72 0.24 0.2069 0.75 0.25 0.2524 Table II-6 is based on AmerGen Energy Document ECR TM 01-00328, Revision 1 (Reference 22).

Table 1I-7 Leakage Results and Inputs for Volumetric ID IGA Indications

  • The assumed number of leaking indications is the maximum number of indications in the untested population that might leak (with >95%, confidence) based on the tested population results.
    • Leak rate is detennined by multiplying the assumed number of leaking indications by the average leak rate per indication.

35 SGA I

SGB Number of Indications Detected 1121 j

103 Average Calculated Leak Rate Per Indication (gpm Oa, 600F) 0.00100 0.00141 Number of Indications In Situ Leak Tested 69 Number of Leaking Indications During In Situ Tests 0

Assumed Number of Leaking Indications in Untested Population

  • 47 3

Confidence Level 95.3%

96.6%

Calculated Leak Rate for ID IGA in Untested Population

<=t0.047

<=0.004 (gpm 0). 600F) **

TR-151, Revision 0 TRENDING OF WEAR INDICATIONS During the 1R14 inspection, a new process was implemented where some of the wear indications were depth-sized with the bobbin coil probe. In accordance with the Analysis Guidelines (Reference 20)., all of the following criteria had to be met in order for a bobbin depth to be assigned. if one or more of these five criteria were not met, thcn the 1

"iW Tr\\-T tn,."l T -r.*

signal was reported as iNQ ad.an.......

eai.iiatiion was performed on that location.

1) the bobbin estimated depth must be less than 3 0TW.
2) the indWcation must bc located at the 01 S through 13 ) SLPPorI plates,
3) the indication must have been reported as wear during the previous inspection,
4) the change in the phase angle from the previous inspection must be less than 10 degrees, and
5) the change in the voltage from the previous inspection must be less than 0.50 volts.

In the previous 13R inspection, wear indications were depth-sized with MRPC.

Table 111-8 provides a summary of the growth of the wear indications based on the voltages and depth estimates from both the bobbin coil and the MRPC probes.

Since bobbin depths were not reported during the 13R examination, the bobbin depths used for this growth analysis were obtained from Reference 23, a study, which looked back at the 13R examination data. As shown in the table, no significant growth of the wear indications has occurred for the operating period listed.

For the bobbin and MRPC depth estimates and the bobbin voltages, no significant differences between the two steam generators were apparent.

Table M11-8 Growth of Support Plate Wear Indications Eddy Current Operating Average Maximum Standard Indication Parameter Period Change Growth Deviation Quantity Bobbin Volts 13R to 1R14

-0.012V

+0.52V 0.11 IV 280 Bobbin % TW 13R to 1R14

-0.5%TW

+6% TW 2.6% TW 162 NRPC Volts 13R to 1R14

-0.018V

+1.25V 0.422V 108 MRPC % TW 3Rto 1R14

-1.2% TW

+9% TW 4.3%TW 108 TUBE DENT SIGNALS The growth of dent signals was calculated based on the bobbin voltages of the dents. Based on the results of this analysis, there was no significant growth of dents during the previous operating cycle.

Tables 111-9 and III-10 show the voltage and voltage growth statistics based on the locations of the dents. As shown in the tables, the average growth was 0.04 volts in OTSG-A and 0.23 volts in OTSG-B. In both steam generators, the largest growth rates occurred in dents at the secondary face of the lower tubesheet. The secondary face of the lower tubesheet, however, is also the location of the largest dents. As a percentage of the dent voltage, the growth of the dents at the lower tubesheet is insignificant.

36

TR-151, Revision 0 Table 111-9 Dent Voltage and Voltage Growth Statistics for OTSG A Number of Voltage Growth Location Dent AgS Signals IAvg Iax Ag S

UTS - Secondary Face 124 3.12 11.31

-0.01

+0.72 0.23 LTS - Secondary Face 287 9.85 91.34

+0,36

+5.27 0.93 LTS - Below Secondary Face 391 5.26 53.9

-0.14

+4.84 0.65 Support Plates 4

[3. 17 4.09

-0.10

+0.35 0.32 Other Locations 51 4.19 11.32_1

-0.34

+1.06 0.66 All 857 6.41 91.34

+0.04

+5.27 0.76 Table IrI-10 Dent Voltage and Voltage Growth Statistics for OTSG B Number of Vol age Growth Location AvDent Avg Max Avg Max Std Dev UTS - Secondary Face 114 3.02 14.91

+0.02

+0.41 0.25 LTS - Secondary Face 1046 10.79 72.96

+0.31

+10.04 0.98 LTS - Below Secondary Face 210 5.44 11.24

-0.04

+1.71 0.53 Support Plates 3

3.72 4.48

-0.19

+0.19 0.31 Other Locations 62 3.65 15.67

+0.01

+1.99 0.55 All

]

1435 (j 9.07 1 72.96

+0.23

[ +10.04 1 0.89 OTHER INDICATIONS Ten tubes were evaluated as having outside diameter initiated wall degradation other than tube to tube support plate wear and were dispositioned as defective tubes. This is the same disposition practice as was implemented during Outages 12R and 13R so all indications in this category are considered newly detected degradation. Table III-11 below details information about these indications:

37

TR-151, Revision 0 Table Il1-11 Confirmed Outside Diameter Indications Tube Location Bobbin Indication MRPC Indication Comments A59-72 U07 +i3.67 0.22 volt NQl SVI 0.10" circ by OD Patch IGA 1

__ _0.10" axial length I B9-62 15S -2.02" 0.97 volt NQI SVI 0.27" circ by OD Patch IGA 0.25" axial length B28-42 LTS +1.62" 0.53 volt NQI SVI 0.23" circ by GD Patch IGA 0.14" axial length B65-129 UTS -0.60" 0.55 volt NQ1 SVI 0.33" circ by Tube-to-tube wear 2.75" axial length due to severed tube B66-130 B65-130 15S +45.38 11.44 volt NQI SVI 0.44" circ by Tube-to-tube wear and 0.56 volt NQI 6.34" axial length due to severed tube B66-130 B66-131 15S +45.55 0.65 volt NQI SVI 0.43" circ by Tube-to-tube wear 8.30" axial length due to severed tube B66-130 B67-130 15S +44.85 0.63 volt NQI SVI 0.38" circ by Tube-to-tube wear 6.51 axial length due to severed tube B66-130 B98-1 UTS -5.73 Multiple NQI Multiple SAI

'Groove" IGA indications from indications from 0.11 volts to 0.24 0.09" axial length volts to 0.43" axial length B 119-2 14S -4.55 0.44 volt NQI Two SAI "Groove" IGA indication indications 0.35" and 0.74" axial length B 133-1 12S +0.88" 0.17 volt NQI Two SAI Likely deposit or indication indications 0.37" shallow tube-to and 0.44" axial tube support plate length wear The above table indicates that there were three distinct types of indications. Three tubes (A59-72. B9-62. and B28

42) had OD volumetric "Patch-Like" IGA typical of OD volumetric IGA found in other OTSG's. Two tubes (B98 1 and BI 19-2) had OD "Groove IGA" typical of other OTSG's and those previously observed at TMI-1. Four tubes (B65-129, B65-130. B66-131, and B67-130) were damaged by previously plugged tube B66-130.

(Conditions surrounding severed plugged tube B66-130 are discussed later in Section III.B.5 of this report.)

Tube B133-1 was plugged for two eddy current indications that were classified as "SAT" at the 12"' tube support plate. The indications were conservatively dispositioned as "'SAI" indications because several of the Resolution Analysts were of the opinion that the ECT signals could be indicative of tube wall degradation. This was an unusual indication that was most likely due to a very shallow tube-to-tube support plate wear indication or a change in secondary side deposit condition. This conclusion is based on the following facts:

At 300 kIIz the +Point coil indication phase angle measurements suggest a high through wall flaw

"* The amnplitude of the indication signals do not suggest a deep flaw

"* The signals observed are in the same relative phase plane as "general" tube noise observed at support plates

"* There is no evidence of phase shifi during entry into and exit away from the signal (commonly referred to as "walking" into and away from the flaw)

"* Phase rotation of the 100 kHz signals suggest shallow through wall or possible debris 38

TR-151, Revision 0 The location of the signals are slightly off the land contacts

"* Confirmation flaw signals are not evident on the 0.80" high frequency or 0. 115" mid frequency pancake coil probes (high through wall flaws should be easily detectable with these probes)

"* Comparison of the historical bobbin signal response indicates that there has been no significant change in the signal Post in situ eddy current examination results indicated no change The Outage 1R14 Condition Monitoring and Operational Assessments considered the impact of the above described degradation (see Section V of this report).

B.2.

Kinetic Expansion Examinations Appendix II includes indications located at ETL (Expansion Transition Location) +0.0" or above as a result of rotating probe examinations.

Structural Integrity The results of the kinetic expansion inspection yielded six tubes that exceeded the conservative criteria for kinetic expansion structural integrity (See Tables 111-15 and lI1-16 that list "Kinetic Expansion Indications" under "Reason For Plugging"). Four of these were in OTSG-A tubes and two of these were in OTSG-B tubes. Thirteen tubes were preventively plugged because they had circumferential indications that were located between ETL +0.0" and ETL +0.50" (ETL is the axial tube location that is identified by the transition from the expansion transition to fully expanded tubing; specifically ETL +0.0" corresponds to that point where the tube is fully in contact with the tubesheet bore.).

Approximately 39% of the in-service kinetic expansions were in the original plan to be inspected. Therefore, there was a possibility of a scope expansion to include the other tubes not examined. The tubes included in the sample were segregated into IS (3%), 2S (6%), and 4S (12%) samples before the outage. In addition, some tubes were scheduled for monitoring of kinetic expansion indications as described in. Tables 111-12 and 111-13, or were required to be examined by the Technical Specifications. These tubes were not part of the iS, 2S, or 4S sample because all tubes meeting the applicable selection criteria were scheduled for examination.

Tables 111-12 and 111-13 show the kinetic expansion examination sanmple results. The "Sanmple Escalation Poinft in the tables is the number of tubes, with defects exceeding the structural criteria, which would have resulted in expanding the inspection to 100% of the in-service tubes. As shown in the tables, six tubes had indications that exceeded the criteria for structural integrity. None of the samples reached the sanmple escalation point. Therefore.,

no increases in examination scope were necessar_,.

Theoretical MSLB Leakage Calculations Based on conservative criteria used to estimate theoretical MSLB leakage, there were a total of 147 leakage contributing indications (92 in SGA; 55 in SGB). Only 9 of these indications (5 in OTSG-A; 4 in OTSG-B) were "full" leakage contributors.

The remaining leakage-contributing indications had the leakage reduction factor applied owing to their locations within the tubeshect expansions. Of the 147 leakage contributors. Il l were in tubes with 17" expansions.

All of the in-service kinetic expansions have now been inspected with Plus Point in one of the last three outages and previous leakage-contributing indications were inspected again in 1R14. In addition, the ID IGAISCC in the kinetic expansions is not growing.

Therefore, the indications from the 12R and 13R inspections that were determined to not be leakage contributors can be assiuned to still be in the same condition. (It should also be noted that the ID IGA indications below the kinetic expansion are also not growing. This is supported by the Sign Test and the Paired t-Test results as discussed in Section II.B. 1.)

39

TR-151, Revision 0 Table 111-14 summarizes the results of the theoretical leakage calculations. This taIble includes an "as-found" leakage value and an "as-left" leakage value for each steam generator. The as-found leakage includes,all lekage contributors before plugging. The as-left leakage includes all leakage contributors that were returned to senrice for Cycle 14.

Table 1[1-12 OTSG-A Kinetic Expansion Examination Results Expansion Type 17" 17" 17" 17"/22" Sample iS (3%)

2S (6%)

4S NA

  • Total Tubes Inspected 475 940 3492 250 5157 Acceptable By Structural479 0

) 892 95 3

Acceptance Criterion47903892953 Unacceptable By Structural Acceptance Criterion Sample Escalation Point (i.e.. 1% of inspected population) 35 NA NA Table 111-13 OTSG-B Kinetic Expansion Examination Results Expansion Type 17" 17" 17" 17"/22" Sample 1S (3%)

2S (6%)

4S NA

  • Total Tubes Inspected 475 940 4460 106 5981 Acceptable By Structural 475 4460 104 5979 Acceptance Criterion Unacceptable By Structural 0

0 0

2 2

Acceptance Criterion Sample Escalation Point (i.e.. 1% of inspected population)

D 10 45 NA NA The "NA" Sample category in the above tables includes tubes with previous indications (including previous leakage contributors), and tubes with 22" kinetic expansions located in the interior of the tube bundle.

40

TR-151, Revision 0 Table III-14 Kinetic Expansion Theoretical Leakage Summary SG A SGB 2 Hour Leak Volume Duration Leak Volume 2 Hour Leak Volume D Tura. ion Leak Volume

l.

i As-Found Leakage *

(gallons @ Taw)

As-Left Leakage **

(gallons @ Tav,)

Leakage Limit (gallons @ Tave) 3228 9960 3228 9960

  • The "as-found" leakage includes all leakage contributors before plugging. All of the kinetic expansions were examined using eddy current over outages 12R, 13R, and 1R14 and all previous leakage contributors were re-inspected during 1R14. Therefore, no projection of the leakage for the un-inspected tubes is required.
    • The 'as-left" leakage includes all leakage contributors that were returned to service for Cycle 14.

B.3 Lower Tubesheet Examinations No service induced degradation was identified during these examinations.

B.4.

Sleeve Examinations No service induced degradation of 1-690 sleeves or of parent tubes with installed sleeves was identified during any of these examinations.

B.5.

Severed Tube B66-130 During the 1R14 inspection, four neighboring tubes of tube B66-130 were found to have indications of wear in the upper span just below the upper tubesheet. The four tubes affected were B65-129, B65-130, B66-13 1, and B67 130. These tubes are all adjacent to plugged tube B66-130. Plus Point inspection of the affected tubes confirmned the presence of long wear indications in the upper span just below the tubesheet. The wear indications ranged from about 2.75" to about 8.3" in length.

In order to evaluate the root cause for the wear on the subject tubes, the upper tubesheet plug of tube B66-130 was removed to facilitate bobbin coil eddy current and video examinations. The bobbin coil inspection of the tube produced very noisy data that was later determined to be due to the fact that the tube was expanded significantly (i.e., -swollen" beyond nominal tube dimensions). The video inspection from the upper tube end confinned that the tube was severed 360 degrees at the secondarv face of the tubesheet. Based on the pattern of the affected tubes and subsequent visual examinations, it was confinred that tube B66-130 was severed and had impacted the adjacent tubes listed above.

41

TR-151, Revision 0 An investigation was performed to determine the root cause of the circumferential failure of tube B66-130. The investigation concluded that the circumferential failure of tube B66-130 was a combined result of the following factors.

"* internal pressurization due to mechanical plug "leak-by" caused the tube to swell during plant heat up(s) and become restrained at both the 15"' tube support plate and the secondary face of the upper tubesheet.

"* The upper span region is located in a high secondary steam velocity flow and velocity profile region (i.e., a periphery tube with higher velocity). When the tube became restrained at its upper span, the tube's damping capability was reduced resulting in susceptibility to flow induced vibration (FIV) fatigue.

"* The presence of existing tube degradation (OD IGA) at the secondary face of the upper tubesheet region became an initiating location for FIV fatigue failure.

Based on the finding of a swollen and severed plugged tube during the course of the inspection, a decision was made to deplug additional tubes in both OTSGs. An extensive inspection of hundreds of deplugged tubes identified a total of 28 other tubes that were swollen as a result of the plugged tube over-pressurization effect. Of these 28 additional swollen tubes, one additional deplugged tube (A2-24), was identified with a circumferential severance that was located at the 15'b TSP. Another swollen deplugged tube, B150-14, was identified with an axial burst between the 15"' TSP and the upper tubesheet. Tube B66-130, however, was the only plugged tube found to have damaged its adjacent tubes.

To address the significance of the wear scars in the four adjacent in-service tubes, in situ pressure testing was performed on three of the tubes (365-129, B66-131, and B67-130). The fourth tube, B65-130, had the deepest measured depth and was tested in a laboratory environment. Tubes B65-129 and B67-130 showed no signs of leakage at in situ test pressures up to 4350 psig (3xNOPD). Tube B66-131, however, failed at the 3xNOPD test pressure. During the final test step for B66-13 1, the tube held pressure at 4360 psig for approximately 1 second with no leakage. After this, the pressure dropped to approximately 450 psig (calculated to be less than 100 psig at the defect) with leakage measured at 3.2 gpm. Video inspection of this location after the test verified that the tube had failed (axial fishmouth) in the area of the wear scar.

In addition to the in situ pressure tests. a secondary-side tube harvest of the severed tube B66-130 as well as two of its neighbors (365-130 and B66-13 1) was performed via the secondary-side manway. As mentioned above, tube B65-130 was pressure tested in the laboratory. As the pressure was being increased to the MSLB test pressure (2900 psig) in tube B65-130, the defect opened and the pressure dropped to zero. The maximum pressure observed in B65-130 was 2979 psig.

Corrective actions were taken during 1R14 to mitigate the occurrence of swollen tubes and the effects of swollen tubes during future operation. The investigative evaluations concluded that this failure is not a likely mechanism in the lower tube span of plugged tubes due to reduced FIV loading.

The corrective actions taken to prevent recurrence of tube severance in a plugged tube and to mitigate the impacts of the plugged tube over-pressurization effect were:

De-watered tubes prior to plugging and re-plugging.

"* Stabilized the upper span region of all tubes that were plugged, or ensured that non-stabilized plugged tubes are surrounded by either stabilized plugged tubes or sleeved tubes.

Tubes that were swollen as a result of the over-pressurization were plugged and stabilized with full-length stabilizers with the following exceptions: Severed tube B66-130 was not required to be stabilized because the upper span region of the tube was removed and all surrounding tubes were either stabilized and plugged or had the upper span removed in order to access tube B66-130 for removal. Swollen tube B150-14 could not be stabilized over its full length because of an obstruction (stuck eddy current probe) near the 7h' TSP.

42

TR-151, Revision 0 B.6.

Plug Examinations The eddy current examinations identified no plug pressure boundary degradation. The eddy current examinations of the upper tubesheet Westinghouse rolled plugs identified 23 plugs in OTSG-A and 19 plugs in OTSG-B that were obstructed at the plug end and would not pass the 0.460" plug probe. Only two of the obstructed plugs

  • ~~1_,-n and B)7-5' reain il seuseid byq1

-LI*1'*'

k. -_

1 1

/_

_) reainl in service fluuowing the iR4 Outage. These obstructions are believed to be caused by repair activities performed in the early 1980's. It is acceptable for these plugs to remain in service because there was no degradation identified from any of the Outage 1R14 plug eddy current examinations and the end damage is very minor in nature.

The scheduled plug visual examinations identified three upper tubesheet Westinghouse plugs (A2-1 I, B78-63, and B77-75) that had identified plug end damage. All three of these plugs were removed during Outage 1R14.

C.

IN-SITU PRESSURE TESTING RESULTS As shown in Tables 11-2 and 11-3, two of the tested locations showed leakage. Tube B66-131 was tested due to wear damage associated with severed tube B66-130. During the final test step for tube B66-131, a pressure of 4360 psig was reached and held for approximately one second with no leakage. After this, the pressure dropped to approximately 450 psig (calculated to be less than 100 psig at the defect) with leakage measured at 3.2 gpm. Video inspection of this location after the test verified that the tube had failed (axial fishmouth) in the area of the wear scar. As a result of this failure, tube B65-129 was added to the test list. Tubes B65-129 and B67-130 were both in situ pressure tested with no leakage detected. Tube B65-130, the tube with the worst mechanical wear damage based on ECT, was harvested from the secondary side and was tested in a laboratory environment. As the pressure was being increased to the MSLB test pressure (2900 psig) in tube B65-130, the defect opened and the pressure dropped to zero. The maximum pressure observed in B65-130 was 2979 psig.

One of the circumferential indications (A53-46) leaked slightly at a very high test pressure. The indication in this tube was an ID circumferential indication located at ETL -1.43".

This tube has a 17 inch kinetic expansion.

Therefore, the circumferential indication is located more than 5 inches into the tubesheet and is not a concern for burst. The leak rate for this tube was measured as 0.014 gpm based on a two minute hold time, but this was at an extremely high pressure of 6450 psig. This tube, as well as 4 other tubes with circumnferential indications, was tested at pressures significantly above 3xNOPD in order to achieve additional axial load. This was done because the axial pull in situ probe got stuck in tube B80-31 (which was the first circumferential indication that was tested).

The test in tube B80-31 was completed successfully with an applied axial load. However, the probe was found to be stuck in the tube upon completion of the test. Due to this probe getting stuck, it was decided that, for the remaining circumferential indications, the additional axial load would be achieved by over-pressurizing the tubes.

There were tlree tubes with circumferential indications on the original in situ test candidate list. Since the leak rate in tube A53-46 was so small, there was no likelihood of violating the NEI 97-06 performance criteria and, therefore, no requirement to test additional circumferential indications per the EPRI Guidelines. However, as a conservative measure, three additional circumferential indications were added to the test list, giving a total number of six circumnferential indications tested.

The in situ pressure test results are provided in Tables 11-2 and 11-3 of this report.

IV.

REPAIRS PERFORMED A.

TUBES PLUGGED DUE TO EDDY CURRENT RESULTS As a result of eddy current indications evaluated during Outage 1R14 examinations twenty-seven (27) tubes in OTSG-A and thirty-one (31) tubes in OTSG-B were plugged. These tubes are listed in Tables 111-15 and 111-16 below:

43

TR-1 5 1, Revision 0 Table IHI-15 OTSG-A Tubes Removed From Service For Eddv Currpnt !ndiratinsel SG Row Tube Reason For Plugging Tb_

Comments Mty Comments SGAI 1

6 SCI ( ETL -0.06 1 1 SGA 2

25 Multiple VOLs 2

SGA 29 100 Kinetic Expansion Indications 3

SGA 33 83 43% ( UTS +1.89 4

SGA 42 89 47% @ UTS +0.69 5

SGA 42 112 Kinetic Expansion Indications 6

SGA 53 46 SCI a ETL -1.43 7

SGA 59 72 SVI c 07S +13.67 8

SGA 72 57 Multiple VOLs (UTS to ETL +3.6) 9 Preventative SGA 72 124 VOL @ ETL -2.46 10 SGA 74 53 SCI @ ETL +0.00 11 Preventative SGA 74 60 SCI @ ETL +0.12 12 Preventative SGA 84 130 SCI @c ETL +0.39 13 Preventative SGA 87 129 40% a UTS +3.54 14 SGA 94 117 VOL 0 UTS -2.31 15 SGA 95 127 VOL ( 12S +13.19 16 SGA 97 33 SCI @ ETL +0.64 17 22" KE; <47" Radius Location SGA 101 51 40% @ UTS +5.83 18 SGA 103 121 VOL (

UTS -0.90 19 SGA 112 85 VOL @ 07S -9.54 20 SGA 116 109 43% @ 15S +36.56 21 SGA 121 89 SCI 0 ETL -0.14 22 SGA 135 2

VOL a15S +11.89 23 SGA 136 69 VOL @ UTS -6.51 24 SGA 146 50 VOL (c 04S -4.94 25 SGA 149 13 Kinetic Expansion Indications 26 SGA 149 31 Kinetic Expansion Indications 27 See Appendix I for indication three letter code definitions and Figure 11-2 for location codes.

44

TR-151, Revision 0 Table 1I1-16 OTSC-B Tubes Removed From Service For Eddy Current Indicautions SG Row Tube Reason For Plugging Tube Comments I

I Qty SGB 9_ I 62 SVI @ 15S -2.02 1

SGB 12 46 40% @ UTS +0.64 2

SGB 21 35 Kinetic Expansion Indications 3

SGB 26 11 SCI @ ETL +0.03 4

SGB 28 42 SVI @ LTS +1.62 5

SGB 28 61 SCI @ ETL +0.44 6

SGB 28 66 Obstructed w/ 540 Bobbin 7

Obstructed wi 540 Bobbin SGB 33 16 SCI @ ETL +0.23 8

Preventative SGB 35 55 SCI @ ETL +0.42 9

Preventative SGB 38 72 40% @ 12S +7.37 10 SGB 44 75 VOL's @ 09S to 15S 11 Preventative / In Situ SGB 55 51 VOL @ 12S -18.4 12 SGB 65 129 SVI @ UTS -0.60 13 SGB 65 130 SVI n 15S +45.38 14 SGB 66 131 SVI @ 15S +45.55 15 SGB 67 130 SVI @ 15S +44.85 16 SGB 73 22 SCI @ ETL +0.00 17 Preventative SGB 78 51 SCI @ ETL +0.01 18 Preventative SGB 78 56 VOL @ ETL -0.40 19 SGB 80 31 SCI @ UTS +0.26 20 SGB 80 58 VOL @ ETL -0.51 21 SGB 83 26 SCI @ ETL +4.92 22 22" KE; <47" Radius Location SGB 84 8

SCI @ ETL +0.31 23 Preventative SGB 95 17 Kinetic Expansion Indications 24 SGB 98 1

SAI @ UTS -5.73 25 SGB 110 12 SCI @ ETL +0.46 26 SGB 119 2

SAI @ 14S-4.55 27 SGB 133 1

SAI @ 12S +0.88 28 SGB 143 43 VOL's @ 06S to 11S 29 Preventative / In Situ SGB 148 26 SCI @ ETL +0.00 30 Preventative SGB 149 1

SCI ft ETL +0.00 31 Preventative B. TUBES PLUGGED TO PREVENT SEVERED TUBE FAILURE Plugged tubes that were not previously stabilized were de-plugged and stabilized in order to prevent re-occurrence of tube-to-tube wear similar to that which occurred in the tubes adjacent to plugged tube B66-130. Plugged tubes that could not be stabilized and had not had upper tube sections removed during a tube pull process were "captured" to prevent damage to adjacent in service tubes should a postulated plugged tube severance occur.

These tubes were "captured" by plugging and stabilizing tubes adjacent to the non-stabilized plugged tubes. In OTSG-A 149 tubes were plugged and stabilized in order to capture tubes that were plugged but not stabilized. In OTSG-B 117 tubes were plugged and stabilized in order to capture tubes that were plugged but not stabilized. Table 111-17 below provides a listing of tubes that were plugged in order to capture adjacent tubes that were plugged but not stabilized.

45

TR-15 1, Revision 0 Table 11-17 Tubes Plugged To Capture Adjacent Tubes Count OTSG Row Tube 1

SGA 2

21 2

SGA 2

22 3

SGA 3

12]

4 SGA 3

13 51 SGA 41 34 6

SGA 4

38 7

SGA 5

37 8

SGA 6

40 9

SGA 6

42 10 SGA 7

42 11 SGA 15 12 SGA 16 2

13 SGA 16 4

14 SGA 17 3

15 SGA 17 4

16 SGA 24 86 17 SGA 24 87 18 SGA 25 87 19 SGA 25 89 20 SGA 26 88 21 SGA 26 89 22 SGA 28 99 23 SGA 39 113 24 SGA 39 114 25 SGA 48 98 26 SGA 48 99 27 SGA 49 98 28 SGA 49 100 29 SGA 50 98 30 SGA 50 99 31 SGA 67 129 32 SGA 72 32 33 SGA 72 33 34 SGA 73 32 35 SGA 73 34 36 SGA 73 129 37 SGA 73 130 38 SGA 74 32 39 SGA 74 33 40 SGA 74 47 41 SGA 74 48 42 SGA 75 47 43 SGA 75 49 44 SGA 75 125 Count OTSG Row Tube 451 SGA 76[

123 461 SGA 771 47 47 SGA 77 48 48 SGA 77 49 49 SGA 79 26 50 SGA 79 27 51 SGA 80 127 52 SGA 80 128 53 SGA 80 130 54 SGA 82 126 55 SGA 82 127 56 SGA 82 128 57 SGA 89 123 58 SGA 89 125 59 SGA 99 124 60 SGA 104 122 61 SGA 105 120 62 SGA 106 118 63 SGA 110 39 64 SGA 110 40 65 SGA 111 38 66 SGA 111 40 67 SGA 112 3

68 SGA 112 39 69 SGA 112 40 70 SGA 113 47 71 SGA 113 48 72 SGA 114 3

73 SGA 114 46 74 SGA 114 48 75 SGA 115 3

76 SGA 115 46 77 SGA 116 1

78 SGA 116 2

79 SGA 116 104 80 SGA 116 105 81 SGA 117 100 82 SGA 117 102 83 SGA 118 100 84 SGA 118 101 85 SGA 119 106 86 SGA 120 104 87 SGA 121 96 88 SGA 121 104 89 SGA 121 105 46 I

TR-151, Revision 0 Table 111-17 Tubes Plugged To Capture Adjacent Tubes (Cont'd)

Count OTSG Row JTube 90 SGA 1221 96 91 SGA 1231 41 92L SGA 123 42 93 SGA 123 95 94 SGA 1241 39 95 SGA 124 41 96 SGA 124 65 97 SGA 124 66 98 SGA 124 97 99 SGA 125 39 100 SGA 125 40 101 SGA 125 64 102 SGA 125 66 103 SGA 125 96 104 SGA 125 97 105 SGA 126 64 106 SGA 126 65 107 SGA 126 95 108 SGA 126 97 109 SGA 127 80 110 SGA 1271 81 111 SGA 128 78 112 SGA 128 80 113 SGA 129 36 114 SGA 129 37 115 SGA 129 78 116 SGA 129 79 117 SGA 130 35 118 SGA 130 37 119 SGA 130 91 120 SGA 131 34 121 SGA 131 35 122 SGA 131 90 123 SGA 132 12 124 SGA 132 13 125 SGA 134 10 126 SGA 134 11 127 SGA 134 74 128 SGA 135 47 129 SGA 135 48 130 SGA 135 71 131 SGA 136 46 132 SGA 136 48 133 SGA 137 45 134 SGA 137 46 Count OTSG Row

[Tube 135 SGA 1401 67 136 SGA 146]

43 1371 SGA 1471 11 138 SGA 147]

17 139 SGA 1471 18 140 SGA 147 38 141 SGA 147 42 142 SGA 148 9

143 SGA 148 10 144 SGA 148 14 145 SGA 148 16 146 SGA 148 36 147 SGA 149 11 148 SGA 149 12 149 SGA 149 32 1

SGB 8

36 2

SGB 8

37 3

SGB 9

38 4

SGB 9

40 5

SGB 10 39 6

SGB 10 40 7

SGB 10 41 8

SGB 10 47 9

SGB 11 40 10 SGB 11 42 11 SGB 11 48 12 SGB 11 50 13 SGB 12 42 14 SGB 12 43 15 SGB

.12 50 16 SGB 17 58 17 SGB 17 59 18 SGB 18 59 19 SGB 18 61 20 SGB 19 60 21 SGB 19 61 22 SGB 28 2

23 SGB 28 3

24 SGB 29 5

25 SGB 29 67 26 SGB 29 68 27 SGB 30 2

28 SGB 30 3

29 SGB 30 4

30 SGB 30 5

47

TR-151, Revision 0 Table 111-17 Tubes Plugged To Capture Adjacent Tubes (Cont'd)

Count OTSG Row Tube 31 SGB 30 67 32 SGB 30 69 331 SGB 311 2

34 SGB 311 4

35 SGB 311 681 36 SGB 31 69 37 SGB 32 3

38 SGB 35 69 39 SGB 35 70 40 SGB 36 71 41 SGB 36 73 42 SGB 37 72 43 SGB 37 73 44 SGB 41 6

45 SGB 42 7

46 SGB 43 6

47 SGB 43 7

48 SGB 43 15 49 SGB 43 16 50 SGB 44 15 51 SGB 44 17 52 SGB 45 16 53 SGB 45 17 54 SGB 66 129 55 SGB 67 79 56 SGB 67 80 57 SGB 67 129 58 SGB 68 79 59 SGB 68 81 60 SGB 69 80 61 SGB 69 81 62 SGB 73 19 63 SGB 75 56 64 SGB 75 57 65 SGB 75 58 66 SGB 77 56 67 SGB 77 58 68 SGB 78 40 69 SGB 78 41 70 SGB 79 40 71 SGB 79 42 72 SGB 79 45 73 SGB 79 46 74 3GB 80 21 Count I OTSG Row Tube 75 SGB 301 67 76 SGB 301 69 77 SGB 311 2

78 SGB 311 4

79 SGB 311 68 80 SGB 31 69 81 SGB 32 3

82 SGB 35 69 83 SGB 35 70 84 SGB 36 71 85 SGB 36 73 86 SGB 37 72 87 SGB 37 73 88 SGB 41 6

89 SGB 42 7

90 SGB 43 6

91 SGB 43 7

92 SGB 43 15 93 SGB 43 16 94 SGB 44 15 95 SGB 44 17 96 SGB 45 16 97 SGB 45 17 98 SGB 66 129 99 SGB 67 79 100 SGB 67 80 101 SGB 67 129 102 SGB 68 79 103 SGB 68 81 104 SGB 69 80 105 SGB 69 81 106 SGB 73 19 107 SGB 75 56 108 SGB 75 57 109 SGB 75 58 110 SGB 77 56 111 SGB 77 58 112 SGB 78 40 113 SGB 78 41 114 SGB 79 40 115 SGB 79 42 116 SGB 79 45 117 SGB 79 46 48

TR-151, Revision 0 The total number of tubes plugged in OTSG-A is 1.512 (9.74% of the 15.531 tubes), and the total number of plugged tubes in OTSG-B is 552 (3.55% of the 15.,531 tubes).

The 80" sleeves installed in the TMI-1 OTSG's affect primary coolant flow and alter the effective plugged percentage of tubes. Per Reference 15, 6.7 tubes with 80" sleeves installed are hydraulicalb, equivalent to I plugged tube:

"° The effective plugging percentage of OTSG-A, considering the 1R14 Outage tube plugging and the effect of its 248 in-service sleeves, is now 9.97%.

[ (1512 + (248/6.7)) / 15531 = 0.0997 ]

"* The effective plugging percentage of OTSG-B, considering the 1R14 Outage tube plugging and the effect of its 253 in-service sleeves, is now 3.80%.

[(552 + (253/6.7)) / 15531 = 0.0380]

C.

PLUGGED TUBE REPAIRS Corrective measures were completed in order to prevent future damage to tubes similar to the damage that occurred as a result of the failure in plugged tube B66-130. These corrective measures are summarized below:

Deplugged tubes were dewatered prior to their re-plugging. This minimized the water remaining within the plugged tubes that could subsequently over-pressurize the tube.

Plugged tubes were stabilized in their upper spans from the upper tubesheet through the 14th tube support plate, or additional tubes were plugged and stabilized to ensure that non-stabilized plugged tubes are surrounded by stabilized, plugged tubes, or sleeved tubes.

27 of 29 swollen tubes were stabilized with full-length stabilizers and plugged. Tube B 150-14 was stabilized only in the upper tube span due to a stuck eddy current probe near the 7h TSP. Severed tube B66-130 was not stabilized because the upper span region of the tube was removed as part of the investigation, and all surrounding tubes were either stabilized and plugged or had the upper span removed in order to access tube B66-130 for removal.

V.

CONDITION ASSESSMENTS A.

CONDITION MONITORING Condition monitoring evaluations consider the "as found" condition of the steam generators, and the ability of the steam generators to withstand hypothetical plant transients over the course of the operating cycle prior to the outage. The 1R14 Outage exanminations determined that swollen, plugged tube B66-130 became circunmferentially severed and impacted four of its adjacent tubes during the prior cycle. The wear damage on these adjacent tubes was of sufficient extent that two tubes did not satisfy the planfs steam generator program requirements for leak/burst integrity at three time the plant's normal operating differential pressure (i.e., 3NODP). Thus, the tubing failed its condition monitoring requirements. A Licensee Event Report (Reference 14) was submitted as a result of this condition.

Aside from the swollen, plugged tube condition described above, the following items are also pertinent to condition monitoring evaluation:

The primary-to-secondary leakrate from the TMI-1 steam generators during the cycle preceding the 1R14 Outage was very low. During the last week of the operating cycle the calculated leakrate was less than 1.5 gallons per day.

During the outage all of the in-service tubes were inspected using eddy current probes. The eddy current test results were screened in accordance with the EPRI Guidelines to select flaws for in situ pressure testing from a leakage and structural integritý perspective. Successful testing of the screened flaws would then provide assurance that the remaining flaws would maintain structural and leakage integrity during a postulated MSLB, In-situ pressure testing was conducted during the 1R14 outage to assess the ability of the flaws found during the eddy current inspections to withstand a postulated Main Steam Line Break (MSLB) event on the last day of the just completed operating cycle. As described in Section 11 the tubing was subjected to pressure loads corresponding to Normal Operating. Main Steam Line Break. and 3NODP. Tables 11-2 and 11-3 of this document provide detailed 49

TR-151, Revision 0 information on the eddy current results for the tubes and indications selected for in-situ pressure testing. Table III 4 provides information on a tube (B65-130) that was pressure tested under laboratory conditions. Seven (7) in situ pressure tested tubes had indications exceeding the EPRI In Situ Testing Guidelines screening criteria, and a total of 21 tubes were in situ pressure tested. Based on the 1R14 in situ pressure testing and examination results. in service tubes (with the exception of B65-130. which is a tube adjacent to tube B66-1130). would have maintained structura-1 aill lc a'Ke interglity, uLrlin a posUbLIatdLU i.vLB a.JUJCIL Oth UISl Ui ty Od ua I ll cyuci plc~dinig tUh outage.

As discussed in Section II.C.2, eddy current indications in the upper tubesheet kinetic expansions were assumed to leak during a postulated MSLB if their through wall extent (as estimated by a Plus-Point coil) was 67% TW or greater. Each of these potential "leakage contributor" indications was conservatively evaluated to determine the volume of primary-to-sccondary lcakage associated with that indication if an MSLB had occurred. These accident induced leakage volumes were summed for each of the indications to predict the hypothetical leakage from all of the expansions. The resulting calculated leakage was considerably less than that allowed by the plant's FSAR.

(See Table 111-14.)

As discussed in Sections II.D and III.C, a large sample of volumetric ID IGA indications was in situ pressure tested, with no leaks, to demonstrate that the remaining population of volumetric ID IGA indications will leak less than a very small amount. This testing was done in accordance with the plant's Technical Specifications to evaluate theoretical leakage of the population of ID IGA indications during accident conditions.

All of the plant's in-service steam generator tubes were inspected. In-situ pressure testing was a primary tool to demonstrate the ability of the freespan tubing to withstand accident-induced loads at the end of the just-completed operating cycle. The kinetically expanded tubing was examined with MIRPC probes and an assessment of the postulated leakage was conservatively developed.

The degradation observed during the 1R14 Outage was evaluated in a manner consistent with NEI 97-06 and the EPRI Guidelines. The evaluations indicated that., with the notable exception of the tubes adjacent to plugged tube B66-130, the observed degradation did not present serious challenges to the structural margin requirements at the end of the last cycle of operation, or challenge the plant's leakage integrity limits. The degraded integrity of the tubes adjacent to plugged tube B66-130 is the subject of LER T2001-003-00 (Reference 14).

B.

OPERATIONAL ASSESSMENT As described in previous sections, in response to the plugged tube B66-130 severance issue, the TMI-l IR14 Outage resulted in 266 tubes (149 in the "A" OTSG; 117 in the "B" OTSG) plugged in order to surround previously plugged tubes with stabilized plugged tubes. In addition, tubes (4 in the "A" OTSG; 9 in the "B" OTSG) were preventively plugged. Forty-five tubes (23 in the "A" OTSG: 22 in the "B" OTSG) were plugged as a result of the eddy current examination results.

ID-initiated indications were the predominant eddy current examination result for which TMI-1 steam generator tubes were plugged. The I.D. indications are believed to be renmants of the thiosulfate damage that occurred to the ID surfaces of the tubes in 1981. As discussed in Section III.B.1, the growth rate for ID IGA indications/flaws is believed to be zero and the ID IGA indications requiring repair were generally the result of N/vRPC examinations in areas not previously examined or were due to variability in the eddy current examination process.

TMI-1 has now examined all of the steam generators' in-service kinetic expansions over the last 3 outages with MIRPC probes. As reported in Section III.B.2. TMI-1 compared the kinetic expansion inspection results of the last three outages and has concluded that the indications within the kinetic expansions are not growing.

An operational assessment of the 1R14 Outage inspection results was successfully performed using methods consistent with NEI 97-06 and the EPRI Guidelines. The corrective actions undertaken in response to the severed.

plugged tube issue should eliminate the possibility of an in-service tube being similarly impacted during forthcomuing cycles. When considering Outage 1R14 corrective actions, indications detected during Outage 1R14.

and indications assumed to remain in service following the 1R14 Outage. the probability of rupture/burst of a tube under postulated TMI-1 MSLB accident loads supports full cycle operation. The operational assessment report is available at the site for NRC staff inspection, if desired.

50

TR-151, Revision 0 VI.

CONCLUSIONS Based on the results of the 2001, Outage 1R14 ECT examinations, tube pulls, in situ pressure testing, and data evaluations, TMI-1 was able to reach the following conclusions:

1.

Evaluation of the ID IGA indications continues to indicate no trend of ongoing degradation.

2.

"Groove iGA" is an active damage mechanism at TMI-1. However. the small number of indications and growth rates continue to support full cycle operation.

3.

Tube-to-tube support plate wear is not an active damage mechanism.

4.

Lower tubesheet OD degradation was not detected during examination of the most susceptible regions with MRPC probes.

5.

The installed Inconel 690 sleeves, and parent tubing, continued to perform without degradation.

6.

OD volumetric IGA (similar to OD volumetric IGA in other OTSGs) continues to be detected at TMI-1 in small numbers and is not a tube integrity issue based on eddy current examination and in situ pressure testing results.

7.

As a result of the plugged tube B66-130 severance, root cause/condition monitoring evaluation determined that OTSG-B did not meet requirements for safety margins against burst during an MSLB during the last several days of Cycle 13. (Refer to Reference 14).

8.

Repairs performed during Outage 1R14 eliminated severed plugged tubes as a potential damage mechanism for adjacent in service tubes during future cycles.

9.

Operational assessment evaluation determined the steam generators are acceptable for full Cycle 14 operation.

Vwi.

REFERENCES

1.

TMI-1 Technical Specification 4.19, "OTSG Tube Inservice Inspection".

2.

TMI-1 Technical Specification License Amendment No. 237., effective October 5. 2001.

3.

Letter from J. Knubel of GPU Nuclear to USNRC. "Cycle 11 Refueling (1 R) Outage Once Through Steam Generator (OTSG) Tube Inspection Report with ASME Form NIS-1 Covering the I IR OTSG Inservice Inspections", 08/01/96.

4.

Three Mile Island Nuclear Station Unit No. I Surveillance Procedure 1300-4B, Rev. 11, "Eddy Current Examination of OTSG". 10/04/01.

Framatome Teclhologies Procedure 54-ISI-400-1l1, "Multi-Frequency Eddy Current Examination of Tubing".

6.

GPU Nuclear Calculation C-1 101-224-E280-072. Revision 1. -ID IGA Flax Detection and Sizing Performance for the Bobbin Coil Eddy Current Examination Tecluique".

7.

Frainatome Technologies Report 51-5000345-01. J. Griffith. --PWSCC and Primary Side IGA Sizing Performance of OTSG Rotating Coil Examinations", 08/04/99.

8.

Exelon Procedure ER-AP-335-040. "'Aal\\ sis of OTSG Eddy Current Data". 08/08/01.

EPPJ Reporl TR-107569-VIR5. 'PWR Steam Gencrator Examnination Guidelines. Revision 5"'. September 1997.

51

TR-151, Revision 0

10.

ASME Boiler and Pressure Vessel Code,Section XI, "Rules for Inservice Inspection of Nuclear Power Plant Components". 1995 Edition With 1996 Addenda.

11.

USNRC Regulatory Guide 1.121, "Bases for Plugging Degraded PWR Steam Generator Tubes". August 1976.

12.

Franmatoirac Tech-nloge Rport 51-5015677-00,

-lu-Situ Pressure Test Summarux foi.. 14U Unit i (October 2001)",

December, 2001.

13.

Letter from j. Langenibach of GPU Nuclear, "Leakage Assessment Methodology for TMI-1 OTSG Kinetic Expansion Examination, Topical Report 116", 11/26/97.

14.

LER Number 2001-003-00, "Degraded OTSG Tube", dated December 14, 2001.

15.

FTI Calculation #32-1234876-00, Rev 0, "TMI-1 Tube Plugging RCS Flow Prediction", July 1995.

16.

"TMI-1 Outage 1R14 Degradation Assessment & Condition Monitoring Checklist,. Revision 0". Memorandum TMI-NOB-3, 5973-2001-009.

17.

Framatome Technologies report 51-5005406-0 1, "Qualified ET Exam Techniques for Three Mile Island 1R14".

18.

Letter from J. Langenbach of GPU Nuclear to USNRC, "GPU Nuclear Response to NRC Requests Regarding the OTSG Kinetic Expansion Region Inspection Acceptance Criteria for 12R Examinations", 07/30/99.

19.

EPRI Report TR-107620-R1., "In-Situ Pressure Test Guidelines: Revision 1"

20.

Exelon T&RM ER-TM-335-1005, "Analysis of OTSG Eddy Current Data At TMI"

21.

Framatome ANP Report 77-5011531-00, "Bobbin Coil OTSG Wear Depth Sizing"

.2.

AmerGen Energy Document ECR TM 01-00328, Revision 1. "Management Program for Volumetric Inside Diameter Intergranular Attack (ID IGA) in Once Through Steam Generators", October 2001

23.

Franmatome ANP Report 51-5011828-00, "TMI - Sizing Wear With Bobbin Data"

24.

NRC Information Notice 2002-02, "Recent Experience With Plugged Steam Generator Tubes".

52

TR-135, Revision 0 Appendix 1 ANALYSIS CHARACTERIZATION AND REPORTING CODES Code Definition Absolute Drift Indication -- reported when the analyst interprets an absolute bobbin signal ADI as anomalous and requiring further disposition that cannot be properly reported with a differential channel.

Axial OD Anomaly -- an axial indication observed during the MIRPC examinations of AOD plugs which is outer diameter initiated and, based on the formation of the signal, does not appear to be degradation of the plug.

ARC Length - signifies a circumferential length measurement has been recorded. Denotes that the measurement in the volt field is the circumferential length measurement of an ARC indication in inches and the measurement in the DEG field is the circunfcrential extent measurement of an indication in degrees. Requires activation of two measurement features in the CScan user selects window.

BLG Bulge -- an indication that the diameter of the tubing has been altered in a bulge-like fashion (increase in tubing diameter).

BNF Bobbin Not Found -- used to disposition a bobbin examination for an indication noted with a rotating exam which is not present (NDD) in the bobbin data.

Bobbin Not Reportable -- used to disposition a bobbin examination for an indication noted BNR with a rotating exam when the indication is present but not reportable in the bobbin data.

Below Voltage Criteria -- an indication evaluated with the bobbin probe to be ID originated BVC and less than 0.4 volt (based on 4 volt normalization) and less than 3:1 signal-to-noise ratio and is therefore not applicable for the assignment of a %TW depth measurement.

Clip Plot Measure -- denotes that the measurement in the UTIL 1 field is the circumferential CLP length measurement of an indication in inches and the measurement in the UTIL2 field is the axial length measurement of an indication in inches.

Circumferential OD Anomaly - a circumferential indication observed during the MRPC COD examinations of plugs which is outer diameter initiated and, based on the formation of the signal, does not appear to be degradation of the plug.

DDI Distorted Dent Indication-A dent indication that displays abnormal formation with possible tube wall degradation present.

Distorted Roll Signal -- a sleeve roll which displays distortion not associated with DRS degradation.

An example of this may be a roll with one transition displaying a sharp entrance or exit similar to probe "snap"., but which cannot be removed through successive examination using push or pull techniques.

Final Calibration -- a code used in a calibration report line entry to signify, that the FC associated data in that entry relates to the final or ending calibration for that particular calibration group of examination data.

Final Calibration Late -- a code used in a calibration report line entry to signift' that the FCL associated data in that entry relates to the final or ending calibration and that the calibration was recorded late (in excess of four hours from the initial calibration time).

Geometric Discontinuity -- an indication which represents a change in material geometry GMD with no associated de-adation.

Historical Review -- a code used in the UTILI field to document compliance with a HR requirement to review historical examination data for a particular indication.

Initial Calibration -- a code used in a calibration report line enti to signify that the IC associated data in that entry relates to the initial or beginning calibration.

ID Chatter - caused by manufacturing process (pilgering). Characterized by long areas of IDC horizontal signal motion.

Tube Identification OK - a code used in the UTILI field to document compliance with a requirement to review current examination data for duplicate tube encodes. In this case. a ID OK duplicate tube encode exists in the saune exainimation tecluiique signifying the tube was examined more than once and it is desired to verifV and document the accuracy of the examinations.

1

TR-135, Revision 0 Appendix I ANALYSIS CI-ARACTERiZATiON AND REPORTING CODES (Cont'd)

Code Definition indication Not Found -- this designator is used onliy if a previously identified indication is INF not recurring.

In this case, a tubing number check shall be performed and tubesheet signature shall be reviewed to verify that the correct tube is being examined.

N indication Not RItportab*le - an iHdicaiun 'uhat has been previously reportLdU.u.t uUh nut meet current reporting criteria.

Irregular Roll - a sleeve roll which displays irregularity not associated with degradation.

IRR An example of this may be a roll with a tapered expansion, a much smaller or larger expansion than normal, a very short expansion, or a case where the two lower expansions overlap resulting in what appears to be one long roll.

LEN Length Measure -- denotes that the measurement in the Volts field is the axial length measurement of an indication in inches.

Loose Part Indication -- used to identify tube wall degradation that is believed to be a LPI result of contact with a loose part. The loose part may or may not be present. Adjacent tubes shall be checked to determine if other tubes have been affected by the loose part.

MAI Multiple Axial Indication -- an MRPC call determiined from indication morphology Machine Burnish Mark (or Manufacturing Buff Mark) -- an indication believed to be MBM produced from a condition resulting from final hand polishing or grinding operations during manufacture to remove imperfections on the tube's outer surface. An indication must have repeatable history to be considered an MBM (MiRPC examinations only).

MCI Multiple Circumferential Indication

-- an MRPC call detenmined from indication morphology Mixed Mode Indication -- an MRPC call determined from indication morphology. This code shall only be used if the indication morphology reflects a situation which would lead the analyst to believe that an axial and circumferential indication have linked in some fashion (for example a T or L shaped crack-like indication).

MVI Multiple Volumetric Indication -- an MRPC call determined from indication morphology No Detectable Degradation -- designator used for an examination that indicates that the NDD region inspected is free of detectable degradation. The actual entry of the code is not required.

No Degradation Found -- designator used for a rotating exanmination to disposition an area of interest that another technique has flagged as needing to be inspected, but when NDF inspected with the rotating technique no degradation was identified. The actual ent.' of the code is required along with the location identified by the implementing examination and the actual extent from the rotating techmique.

NEX No Expansion -- no roll or expansion where one should be.

NFC No Final Calibration -- designator used to identify that the calibration run at the end of a calibration group was not perforned.

Non-Quantifiable Indication -- an ET signal identified by the bobbin analyst as possibly containing an indication: however, due to noise, lack of multi-frequency channel NQI correlation, or other signal peculiarities, the analyst cannot sufficiently interpret the signal to draw any conclusion. This is an interim disposition.

NSY Noisy Tube -- An area of the tube that is too noisy to properly evaluate exanination data (MRPC examinations only).

OBS Obstructed Tube -- used only if the acquisition operator has identified the tube as being unable to pass tie probe due to a restriction or blockage.

Prior Bobbin Analysis -- code assigned to a specific data record to provide a means of PBA clearing the record through data management without re-reporting indications already reported during a previous bobbin coil scan of the satme area.

Plug End Anomaly - indications located completely outside the plug pressure boundanr.

For rolled plugs. this area includes only the heel transition and outboard end of the plug.

2

TR-135, Revision 0 Appendix I ANALYSIS CHARACTERIZATION AND REPORTING CODES (Cont'd)

Code Definition Positive identification -- this designates that at least one confirming ET inspection has been performed on the area of interest with the results indicating that the initial and confirming analysis results are in concurrence.

Analysts will use the exact location from the ind;cation of interest when reporing the PID.

PLG Plugged - permanent plug installed in a tube.

Possible Loose Part -- shall be reported when ET provides evidence of a possible loose PLP part adjacent to or in the vicinity of a tube. Adjacent tubes shall be checked to determine if there is a PLP signal or any indication of wall loss from the loose part.

Prior Rotating Analysis -- code assigned to a specific data record to provide a means of PRA clearing the record through data management without re-reporting indications already reported during a previous rotating probe scan of the same area.

PVN Permeability shall be reported only if suspected of masking an indication or as otherwise required by a specific ETSS requirement Retest Axial Speed -- used to signify that the axial speed for the examination exceeded the ETSS requirements RBD Retest Bad Data -- Self explanatory Retest Clarification - used to signify the result is inconclusive and an additional exam is required.

RDR Retest Digitization Rate - used to signify that the digitization rate for the examination in the area of interest did not comply with the minimum requirements of the applicable ETSS.

REC Retest Encoding Channel -- used to signify that the encoding channel displayed bad data and the encoder was required to be present by the applicable ETSS.

RIC Retest Incomplete -- Data-self explanatory RMB Retest with a magnetically -- biased probe RNC Retest -- tube number check ROB Retest -- obstructed RPC Retest -- MRPC exam required RPD Retest Positive -- Identification-self explanatory RPN Retest Parasitic -- Noise-self explanatory RPP Retest Pancake - Pluspoint Exam Desired-A retest code entered by the lead analyst to signify additional required diagnostic testing.

Retest Presence of Signals -- used to signify that a retest is required because signals were missing from required channels Retest Probe Wear - used to signify that a retest is required because final calibrations for RPW the calibration group indicated the probe wear requirements were exceeded.

RRN Retest Rotational Noise -- self explanatory RRS Retest Rotation Speed -- used to signift a retest is required because the MIRPC examination rotational speed did not comply with applicable ETSS requirements Retest Saturated Channel -- used to signify a retest is required because required analysis channels displayed saturated data in the area of interest.

RSD Retest Signal Dropout -- used to signify a retest is required because required analysis channels displayed data dropout in the area of interest.

Retest Signal-to-Noise -- used to signif. a retest is required because there was insufficient signal to noise in the required analysis channels in the area of interest.

SAI Single A.xial Indication -- an MRPC call detennined from indication morpholog)

SC1 Single Circumnferential Indication

-- an MIRPC call detemlined from indication nmorphology SLG Sludge -- designator used to annotate sludge elevation 3

TR-135, Revision 0 Appendix I ANALYSIS CH,rARAC.,TErRIZATION AND REPORTTNG CODES (Cont'd)

Code Definition SLV Sleeve indication -- all indications observed in the sleeve materiai shall be identified withf this code in UTILl field.

SSA Secondary Side Anomaly - an indication believed to be produced from foreign material on ULth secondary side., w~hich is not a loose part k(MRPC cxamiinat-oiosUuJ S_

Single Volumetric Indication -- an MRPC call determined from indication morphology TSD ITube Support Plate Damaged -- tube support plate appears to be significantly eroded/damaged.

TSM Tube Support Plate Missing -- no tube support plate signal is present at the expected location.

TUB Parent Tubing Indication -- any indication in the parent tube material in the sleeved region shall be identified with this code in UTILl field.

Volumetric Indication

-- an MIRPC indication that is not crack-like yet has some VOL discernible volume to it and displays signals of inside diameter initiation. For example, an ID IGA indication in the tube freespan.

Wear Call -- used in UTIL1 Field for rotating examinations. Indications will be labeled W WAR only after the criteria for disposition of indications at TSPs is met.

4

TR-151, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A Site:

Three Mile Island This appendix contains all recordahle indications for tubes in serice prior to the ]R]4 Outage. Tubes plugged based on eddy current examination results are highlighted by bold print. Indications of voiwnetric ID IGA are recorded with a code of "FOL ". Axial and circumferential length for both ID and OD volumetric indications are recorded with a code of "CLP'". Circumferential length.for circumferential indications are recorded with a code of 'ARC"' and axial length for axial indications are recorded with a code of "LEN'. "Tff"D" highlights a percent through iiall dimension record.

(Note: Three-letter code "AIRB" was truncated to "Al/.B" in printing this table.)

Outage:

1R14 Volt / Origin/

Location Tube#

Cal Probe Degrees Percent Code TSP - Offset Axial Circ Dataset 1

6 55 520HF 0.75 30 ID 71 SCI ETL

-0.06 KEXP +Pt 1

6 55 5201F 0.00 63 0 ARC ETL

-0.06 0.34 KEXP_+Pt 1

6 95 520HF 1.18 30 0

PID ETL

-0.06 KEXP_+Pt 1

6 140 520PI 0.00 102 0 ARC ETL 0.00 0.55 PostIn_+Pt 1

6 140 520PI 1.56 31 ID 76 SCI ETL 0.00 PostIn_+Pt 1

6 29 51OUL 4.25 178 0

DNT LTE 10.99 510_Bobbi 2

5 30 51OUL 2.46 172 0

INR LTE 11.11 510 Bobbi 2

11 8

460PP 0.00 0

0 OBS UTE 0.00 PlugvRP 2

14 113 540HF 0.28 9

0 BVC 15S 40.91 540_Bobbi 2

14 113 540HF 4.26 177 0

DNT LTE 10.22 540_Bobbi 2

14 160 5201-F 0.00 0

0 NDF UTS

-5.46 R13DCLP+

2 14 160 520HF 0.00 0

0 NDF UTS

-5.29 R13DCLP+

2 15 113 540HF 0.31 2

0 INR 15S 37.00 540 Bobbi 2

21 29 510UL 6.12 174 0 DNT LTE 11.08 510 Bobbi 2

22 168 51OUL 0.58 5

HD 17 TWD 14S 22.24 540 Bobbi 2

22 168 51OUL 0.39 5

0 BVC 14S 29.57 540_Bobbi 2

22 117 540-F 0.30 11 0 BVC 14S 33.27 540_Bobbi 2

22 168 51OUL 0.33 6

0 BVC 14S 33.33 540 Bobbi 2

22 160 520HF 0.00 0

0 CLP 15S

-13.84 0.24 0.22 R13DCLP+

2 22 160 520-F 0.23 4

0 VOL 15S

-13.84 R13DCLP+

2 22 160 5201-F 0.00 0

0 NDF 15S

-12.86 R13DCLP+

2 22 160 5201-F 0.30 18 0

VOL 15S

-5.96 R13DCLP+

2 22 160 5201HF 0.00 0

0 CLP 15S

-5.96 0.24 0.22 RI3DCLP+

2 22 160 520HF 0.00 0

0 CLP 15S

-1.85 0.14 0.16 SpecInt 2

22 160 5201-iF 0.31 17 0 VOL 15S

-1.85 SpecInt 2

22 168 510DUL 8.40 176 0

DNT LTE 10.86 540_Bobbi 2

22 117 5401HiF 0.00 0

0 ROB LTS

-6.94 Sludge 2

22 117 540HF 0.00 0

0 ROB LTS

-6.94 540iBobbi 2

25 138 520PI 0.00 0

0 CLP 12S 20.055 0.23 01.14 Postln_+Pt 2

25 138 520PI 0.30 19 0

VOL 12S 20.05 Postln_+Pt 2

25 138 520P1 0.00 0

0 CLP 12S 20.99 0.18 0.18 Postln_+Pt 2

25 138 520PI 0.64 36 0 VOL 12S 20.99 Postln_+Pt 2

25 113 540HF 0.44 359 0

MNR 12S 21.10) 540_Bubbi 2

25 113 540HF 0.24 4

0 INR 12S 22.99 540_Bobbi 2

25 113 540HF 0.33 9

0 INR 12S 25.82 540_Bobbi 2

25 138 520PI 0.30 32 0

VOL 12S 28.72 Postln -+Pt Page 1 of 325

TR-151, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A sifte:

TEree Mile Is-land All Indications, With Length and Width Outage:

1R14 Tube#

Cal Probe 25 138 25 138 25 138 25 138 25 138 25 138 25 138 25 160 25 160 25 160 25 160 25 160 25 160 25 160 25 160 25 160 25 160 25 160 25 160 25 160 25 160 25 138 25 138 25 160 25 160 25 138 25 138 25 113 25 138 25 138 25 160 25 134 25 160 25 160 25 113 25 138 25 138 25 160 25 160 25 160 25 160 25 113 520PI 520PI 520PI 520PI 520PI 520PI 520PI 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520PI 520PI 520HF 520HF 520PI 520PI 540HF 520P1 520P]

520HF 520HF 520HF 520HF 540HF 520P1 520P1 520HF 520HF 520HF 520HF 540HF Volt / Origini Degrees Percent 0.00 0.00 0.36 0.27 0.00 0.48 0.00 0.18 0.00 0.00 0.30 0.11 0.00 0.00 0.20 0.00 0.30 0.00 0.19 0.52 0.00 0.00 0.45 0.34 0.00 0.83 0.00 0.47 0.00 0.34 0.39 0.77 0.00 0.00 0.47 0.84 0.00 0.38 0.00 0.00 0.40 0.25 0

0 9

29 0

19 0

23 0

0 23 22 0

0 20 0

9 0

16 25 0

0 8

21 0

32 0

6 0

22 15 11 0

0 7

32 0

15 0

0 17 14 Location Code TSP - Offset 0

CLP 12S 0 CLP 12S 0 VOL 12S 0

VOL 12S 0 CLP 12S 0

VOL 12S 0

CLP 12S 0

VOL 13S 0

CLP 13S 0

CLP 13S 0

VOL 13S 0 VOL 13S 0

CLP 13S 0

CLP 13S 0

VOL 13S 0

CLP 13S 0

VOL 13S 0

CLP 13S 0

VOL 13S 0 VOL 13S 0 CLP 13S 0 CLP 13S 0

VOL 13S" 0 VOL 13S 0 CLP 13S 0 VOL 13S 0 CLP 13S ID 20 TWD 13S 0

CLP 13S 0 VOL 13S 0 VOL 13S 0

PID 13S 0

RPD 13S 0

CLP 13S ID 23 TWD 13S 0 VOL 13S 0

CLP 13S 0 VOL 13S 0

CLP 13S 0

CLP 13S 0

VOL 13S 0

INR 13S 28.72 29.99 29.99 32.30 32.30 35.72 35.72

-18.12

-18.12

-16.64

-16.64

-15.26

-15.26

-8.75

-8.75

-7.37

-7.37

-4.87

-4.87

-1.26

-1.26 4.73 4.73 5.14 5.14 9.15 9.15 9.18 9.82 9.82 10.01 10.01 10.01 10.01 10.18 10.18 10.18 10.82 10.82 11.17 11.17 12.95 Axial Cire Dataset 0.25 0.17 Postln_+Pt 0.24 0.16 Postln+Pt PostIn_+Pt Postln_+Pt 0.25 0.18 Postln_+Pt Postln +Pt 0.22 0.18 Postln +Pt R13DCLP+

0.14 0.12 RI3DCLP+

0.19 0.16 R13DCLP+

R13DCLP+

R13DCLP+

0.13 0.11 R13DCLP+

0.24 0.16 R13DCLP+

R13DCLP+

0.19 0.22 R13DCLP+

R13DCLP+

0.39 0.22 R13DCLP+

R13DCLP+

R13DCLP+

0.29 0.22 R13DCLP+

0.14 0.12 Postln_+Pt Postln_+Pt R13DCLP+

0.15 0.16 R13DCLP+

PostIn_+Pt 0.18 0.17 Postln_+Pt 540_Bobbi 0.18 0.18 Postln_+Pt PostIn_+Pt R13DCLP+

R13DCLP+

R13DCLP+

0.29 0.22 R13DCLP+

540_Bobbi Postln_+Pt 0.22 0.18 Postln_+Pt R13DCLP+

0.34 0.22 R13DCLP+

0.24 0.22 R13DCLP+

R13DCLP+

540 Bobbi Page 2 of 325

TR-151, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A Siyte:

Three Mile islan.d All Indications, 14'ith Length and WicIth Outage:

1 RI 4 Volt,/ Origin/

Degrees Percent 0.38 24 Tube#

25 138 25 138 25 138 25 138 25 160 25 160 25 160 25 160 27 73 5

67 7

67 13 29 14 30 15 29 16 29 17 113 17 160 17 160 17 113 17 160 17 160 17 160 17 160 27 29 32 8

8 67 14 30 14 160 14 55 14 55 19 29 20 55 Cal Location Code TSP - Offset Probe 520P1 520PI 520PI 520PI 520HF 520HF 520HF 520HF 51OUL 51 OUL 51 OUL 51 OUL 51OUL 51OUL 51 OUL 540HF 520HF 520HF 540HF 520HF 520HF 520HF 520HF 51OUL 460PP 510UL 510UL 520HF 520HF 520HF 51OUL 520HF 0.00 0

0.38 24 0.00 0

0.00 0

0.15 18 0.00 0

0.31 20 5.32 176 6.39 175 4.45 174 0.29 54 1.91 170 3.28 175 2.74 172 0.39 8

0.31 12 0.00 0

0.38 6

0.00 0

0.26 13 0.00 0

0.28 18 2.72 171 0.18 88 0.19 127 0.17 68 0.38 98 0.00 0

0.22 25 0.08 80 0.45 23 OD OD Pane 3 of 325 0

VOL 13S 0

CLP 13S 0 VOL 13S 0

CLP 13S 0

CLP 13S 0 VOL 13S 0

CLP 13S 0 VOL 13S 0

DNT LTE 0

DNT LTE 0

DNT LTE 5

TWD 05S 0

INR LTE 0 DNT LTE 0 DNT LTE 0

BVC 15S 0 VOL UTS 0

CLP UTS 0

BVC UTS 0

CLP UTS 0 VOL UTS 0

CLP UTS 0

VOL UTS 0 DNT LTE 0 AOD UTE 0

INR LTE 0 NQI 08S 6

TWD 08S 0

CLP ETL 0

VOL ETL 1

TWD 13S 0

VOL ETL 13.15 13.15 13.41 13.41 14.08 14.08 14.40 14.40 10.91 10.65 11.10

-0.74 9.00 10.97 10.90 32.64

-14.69

-14.69 0.37 0.42 0.42 0.49 0.49 10.42

-1.84 17.90 0.69 0.83

-2.08

-2.08 0.32

-0.45 Axial Circ Dataset Posthn_+Pt 0.18 0.18 PostIn_+Pt Postln_+Pt 0.22 0.18 Postln_+Pt 0.24 0.16 R13DCLP+

R13DCLP+

0.24 0.16 R13DCLP+

R13DCLP+

510_Bobbi 510 Bobbi 510 Bobbi 510 Bobbi 510 Bobbi 510_Bobbi 510_Bobbi 540_Bobbi SpecInt 0.19 0.16 SpecInt 540_Bobbi 0.14 0.17 RI3DCLP+

R13DCLP+

0.14 0.12 R13DCLP+

R13DCLP+

510_Bobbi Plug_MRP 510_Bobbi 510 Bobbi Spec Int 0.11 0.15 KEXP +Pt KEXP_+Pt 510 Bobbi KEXP +Pt

TR-151, Revision 0 Appendix 1I Recordable Indications Component:

TMI-OTSG-A Site:

Three Mile Island All Indications, With Length and Width Outage:

1R14 Tube#

Cal Probe 4

4 4

4 4

4 4

4 4

4 4

20 55 20 55 20 55 29 113 29 113 29 133 29 133 29 160 29 160 29 160 29 160 32 56 32 56 32 56 32 56 34 133 34 133 34 133 34 133 34 110 34 133 34 133 34 133 34 110 34 110 34 113 34 113 34 113 38 110 38 123 38 123 3 147 3 147 3 133 3 133 3 133 3 133 3 133 Volt / Origin!

Degrees Percent 0.00 0

0.64 25 0.00 0

0.72 0.26 0.76 0.00 0.00 1.80 0.00 0.00 9

11 15 0

0 16 0

0 520HF 520HF 520HF 540HF 540HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 540HF 520HF 520HF 520HF 540HF 540HF 520HF 520HF 520HF 540HF 520HF 520HF 540HF 540HF 520HF 520HF 520HF 520HF 520HF 0.67 1.14 0.29 0.00 0.00 0.33 0.00 6

9 15 0

0 21 0

Location Code TSP - Offset 0

CLP ETL ID 51 VOL ETL 0

CLP ETL ID 30 TWD 15S 0

BVC 15S 0

VOL UTS 0 CLP UTS 0 RIC UTS 0 VOL UTS 0 CLP UTS 0

NDF UTS ID 43 VOL 0

CLP ID 30 VOL 0

CLP ETL ETL ETL ETL 0 VOL 15S 0

CLP 15S 0

CLP 15S 0

VOL 15S 0

BVC 15S 0

CLP 15S 0

VOL 15S 0 NDF 15S ID 17 TWD 15S 0

DNT LTE 0

RIC UTS 0

VOL UTS 0

CLP UTS 0

BVC 12S 0

CLP 12S 0

VOL 12S ID ID 20 TWD 15S 30 TWD 15S 0 VOL UTS 0

CLP UTS 0

CLP UTS 0 VOL UTS 0

CLP UTS

-0.45 0.86 0.86 27.32 35.97

-19.56

-19.56

-19.06

-11.13

-11.13

-10.41 0.02 0.02 1.02 1.02 2.11 2.11 8.05 8.05 10.32 10.45 10.45 11.41 23.52 10.50

-36.06

-22.78

-22.78 11.31 11.41 11.41 44.00 44.55

-45.01

-45.01

-41.57

-41.57

-40.74 Axial Circ Dataset 0.10 0.15 KEXP_+Pt KEXP_+Pt 0.15 0.20 KEXP_+Pt 540_Bobbi 540 Bobbi R13DCLP+

0.25 0.21 R13DCLP+

R13DCLP+

SpecInt 0.14 0.17 SpecInt SpecInt KEXP_+Pt 0.16 0.18 KEXP_+Pt KEXP_+Pt 0.21 0.23 KEXP_+Pt R13DCLP+

0.10 0.11 R13DCLP+

0.15 0.16 R13DCLP+

R13DCLP+

540_Bobbi 0.10 0.16 R13DCLP+

R13DCLP+

R13DCLP+

540_Bobbi 540_Bobbi R13DCLP+

SpecInt 0.14 0.17 SpecInt 540_Bobbi 0.15 0.11 Rt3DCLP+

R13DCLP+

540_Bobbi 540_Bobbi R13DCLP+

0.14 0.16 R13DCLP+

0.15 0.15 RI3DCLP+

R13DCLP+

0.10 0.10 R13DCLP+

Page 4 of 325 0.78 23 0.00 0

0.45 19 0.00 0

0.25 13 0.00 0

0.00 0

0.23 15 0.35 6

0.00 0

0.19 15 0.00 0

0.41 5

2.71 177 0.00 0

0.33 13 0.00 0

0.30 10 0.00 0

0.37 26

TR-151, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A

ýile."

Three Mile Island All. Indications, With Length and Width Outage:

IR14 Volt / Origin/

Location Tube#

Cal Probe Degrees Percent Code TSP - Offset Axial Circ Dataset 5

3 133 520HF 0.26 11 0

VOL UTS

-40.74 R13DCLP+

5 3 133 520HF 0.00 0

0 CLP UTS

-33.04 0.20 0.10 Rl3DCLP+

5 3 133 520HF 0.25 12 0

VOL UTS

-33.04 RI3DCLP+

5 3 133 520HF 0.21 18 0

VOL UTS

-30.41 RI3DCLP+

5 3 133 520HF 0.00 0

0 CLP UTS

-30.41 0.20 0.15 RI3DCLP+

5 3 133 520HF 0.00 0

0 CLP UTS

-27.25 0.20 0.15 R13DCLP+

5 3 133 520HF 0.92 20 0

VOL UTS

-27.25 R13DCLP+

5 3 133 520HF 0.37 26 0

VOL UTS

-27.02 R13DCLP+

5 3 133 520HF 0.00 0

0 CLP UTS

-27.02 0.20 0.20 R13DCLP+

5 3 133 520HF 0.00 0

0 CLP UTS

-2.29 0.15 0.15 R13DCLP+

5 3 133 520HF 0.61 15 0 VOL UTS

-2.29 RI3DCLP+

5 3 133 520HF "0.00 0

0 CLP UTS

-1.74 0.15 0.15 R13DCLP+

5 3 133 520HF 0.76 17 0

VOL UTS

-1.74 R13DCLP+

5 5 113 540HF 0.24 93 0

NQI 12S 27.03 540_Bobbi 5

5 115 520HF 0.00 0

0 NDF 13S

-9.97 SpecInt 5

5 113 540HF 0.48 6

ID 20 TWD 15S 34.23 540_Bobbi 5

5 113 540HF 2.73 176 0

DNT LTE 10.72 540_Bobbi 5

5 115 520HF 0.00 0

0 CLP UTS

-12.12 0.09 0.11 Spec mnt 5

5 115 520HF 0.43 19 0

VOL UTS

-12.12 SpecInt 5

6 67 51OUL 3.11 175 0

DNT LTE 10.78 510_Bobbi 5

22 8

460PP 0.00 0

0 OBS UTE 0.00 PlugMRP 5

35 12 460PP 0.00 0

0 OBS UTE 0.00 PlugMRP 5

42 76 51OUL 0.43 89 0 INR LTE 11.86 510 Bobbi 6

5 68 51OUL 2.74 175 0

DNT LTE 10.72 510 Bobbi 6

12 51 520HF 0.56 19 0

VOL ETL

-1.03 KEXP_+Pt 6

12 51 520HF 0.00 0

0 CLP ETL

-1.03 0.17 0.19 KEXP_+Pt 6

15 115 520HF 0.99 0

ID 14 TWD 08S 0.55 Spec -nt 6

15 67 510UL 0.72 75 0 NQI 08S 0.68 510_Bobbi 6

20 29 51OUL 0.28 118 0

INR 10S 7.42 510_Bobbi 6

30 29 51OUL 0.25 69 0

NQI LTE 9.50 510 Bobbi 6

30 29 51OUL 0.21 82 0

NQI LTE 14.04 510_Bobbi 6

30 160 520HF 0.00 0

0 NDF LTS

-14.50 SpecInt 6

30 160 520HF 0.00 0

0 NDF LTS

-9.96 Spec_lnt 6

32 29 51OUL 2.76 186 0

DNT 03S 16.73 510 Bobbi Page 5 of 325

TR-151, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A Site:"

Three Mile Island

.411 Indications, 11"ith Length and Width Outage:

1R14 Tube#

Cal Probe Volt / Origin/

Degrees Percent Location Code TSP - Offset Axial Circ Dataset 6

6 0.69 0.75 33 30 33 160 510 Bobbi SpecInt 0.28 75 0.53 74 Page 6 of 325 OD 51OUL 520HF 520HF 520HF 520HF 520HF 540HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 540HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 540HF 520HF 520HF 520HF 520HF 51OUL 520HF 520HF 540HF 520HF 520HF 520HF 520HF 540HF 0

33 28 0

7 9

0 3

0 26 0

0 18 6

47 133 6

47 133 6

47 133 6

47 133 6

47 110 6

47 133 6

47 133 6

47 113 6

47 113 6

47 133 6

47 133 6

47 113 6

47 113 6

48 110 6

48 113 6

48 79 6

48 79 6

48 79 6

48 79 6

48 79 6

48 79 6

48 79 6

48 110 6

48 113 6

48 113 6

48 113 6

48 113 7

1 68 0.00 0.18 0.17 0.00 0.31 0.26 0.00 0.38 0.00 0.93 0.00 0.00 0.57 0.30 0.48 0.14 0.00 0.31 0.16 0.00 0.00 0.34 0.67 0.00 1.09 0.29 0.18 0 NQI 05S 8

TWD 05S 0

CLP 15S 0 VOL 15S 0 VOL 15S 0

CLP 15S 0

BVC 15S 0 VOL UTS 0

CLP UTS 0

VOL UTS 0

CLP UTS 0

VOL UTS 0

CLP UTS 0

CLP UTS 0

VOL UTS 0 NQI 14S 9

TWD 14S 0

INR ETL 0

CLP ETL 0

VOL ETL 0

VOL ETL 0

CLP ETL 0

CLP ETL 0

VOL ETL 27 TWD UTS 0

CLP UTS 0

VOL UTS 0

PRA UTS 0

PRA UTS 0

INR LTE 0

VOL 04S 0

CLP 04S 0

BVC 04S 0

CLP 04S 0

VOL 04S 0

CLP 09S 0

VOL 09S 0

BVC 09S 21.28 21.28 24.88 24.88 40.11

-20.57

-20.57

-12.41

-12.41

-8.43

-8.43

-7.00

-7.00

-0.86

-0.81

-4.03

-3.24

-3.24

-2.70

-2.70

-1.73

-1.73 0.35 0.53 0.53 4.45 5.81 9.62 6.08 6.08 6.83 6.97 6.97 9.81 9.81 10.13 0.15 0.22 RI3DCLP+

R13DCLP+

R13DCLP+

0.15 0.16 R13DCLP+

540_Bobbi R13DCLP+

0.14 0.16 R13DCLP+

RI 3DCLP+

0.19 0.17 R13DCLP+

R13DCLP+

0.15 0.16 RI3DCLP+

0.09 0.17 SpecInt SpecInt 540_Bobbi Specmnt KEXP_+Pt 0.06 0.10 KEXP_+Pt KEXP_+Pt KEXP_+Pt 0.17 0.10 KEXP_+Pt 0.15 0.14 KEXP_+Pt KEXP_+Pt 540_Bobbi 0.14 0.17 Spec_]nt Spec Int Spec Int Spec mnt 510 Bobbi SpecInt 0.09 0.11 SpecInt 540_Bobbi 0.09 0.11 SpecInt SpecInt 0.14 0.11 SpecInt SpecInt 540 Bobbi OD ID 67 118 31 0

21 7

0 0

19 8

0 27 15 23 0.98 114 7

7 7

7 7

7 7

7 2 115 2 115 2 113 2 115 2 115 2 115 2 115 2 113 0.34 0.00 0.26 0.00 0.28 0.00 0.50 0.30 20 0

8 0

19 0

14 9

TR-151, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A Sime:

Three Mile Island All Indications, J1'ith Length and Width Outage:

1R14 Volt / Origin!

Location Tube#

Cal Probe Degrees Percent Code TSP - Offset Axial Circ Dataset 7

2 113 540HF 0.18 95 0

INR LTE 19.86 540_Bobbi 7

4 164 520HF 0.20 16 0

VOL UTS

-14.91 R13DCLP+

7 4 164 520HF 0.00 0

0 CLP UTS

-14.91 0.14 0.11 R13DCLP+

7 4 164 520HF 0.00 0

0 CLP UTS

-14.21 0.14 0.16 R13DCLP+

7 4 164 520HF 0.14 14 0

VOL UTS

-14.21 R13DCLP+

7 4 164 520HF 0.38 23 0

VOL UTS

-13.62 R13DCLP+

7 4 164 520HF 0.00 0

0 CLP UTS

-13.62 0.14 0.11 R13DCLP+

7 4 164 520HF 0.18 47 0

INR UTS

-12.81 RI3DCLP+

7 4 164 520HF 0.12 17 0

VOL UTS

-8.08 RI3DCLP+

7 4 164 520HF 0.00 0

0 CLP UTS

-8.08 0.09 0.11 R13DCLP+

7 4 164 520HF 0.22 18 0

VOL UTS

-1.89 R13DCLP+

7 4 164 520HF 0.00 0

0 CLP UTS

-1.89 0.18 0.16 R13DCLP+

7 4 164 520HF 0.00 0

0 CLP UTS

-0.64 0.14 0.16 R13DCLP+

7 4 164 520HF 0.34 14 0

VOL UTS

-0.64 R13DCLP+

7 4 164 520HF 0.00 0

0 CLP UTS 0.27 0.09 0.11 RI3DCLP+

7 4 164 520HF 0.14 25 0

VOL UTS 0.27 R13DCLP+

7 4 164 520HF 0.34 18 0

VOL UTS 0.87 R13DCLP+

7 4 164 520HF 0.00 0

0 CLP UTS 0.87 0.09 0.16 R13DCLP+

7 36 30 51OUL 1.92 183 0

INR 14S 17.71 510_Bobbi 7

44 70 520HF 0.37 29 0 VOL ETL

-0.09 KEXP_+Pt 7

44 70 520HF 0.00 0

0 CLP ETL

-0.09 0.10 0.16 KEXP_+Pt 7

44 123 520HF 0.22 13 0

VOL UTS

-3.11 R13DCLP+

7 44 123 520HF 0.00 0

0 CLP UTS

-3.11 0.10 0.11 R13DCLP+

7 44 123 520HF 0.43 23 0

VOL UTS 1.28 R13DCLP+

7 44 123 520HF 0.00 0

0 CLP UTS 1.28 0.10 0.11 R13DCLP+

7 44 123 520HF 0.38 23 0

VOL UTS 2.07 R13DCLP+

7 44 123 520HF 0.00 0

0 CLP UTS 2.07 0.10 0.16 R13DCLP+

7 44 123 520HF 0.41 18 0

VOL UTS 3.08 R13DCLP+

7 44 123 520HF 0.00 0

0 CLP UTS 3.08 0.15 0.11 R13DCLP+

7 51 73 51OUL 2.86 176 0

DNT LTE 10.30 510_Bobbi 8

2 113 540HF 0.53 3

0 INR 12S 16.11 540_Bobbi 8

2 113 540HF 0.44 3

0 INR 12S 18.96 540_Bobbi 8

2 113 540HF 0.66 7

ID 23 TWD 12S 29.01 540 Bobbi 8

2 113 540HF 0.76 7

ID 23 TWD 12S 33.38 540_Bobbi 8

2 164 520HF 0.00 0

0 RIC 13S

-18.07 R13DCLP+

8 2 133 520HF 0.51 17 0

VOL 13S

-17.07 R13DCLP+

8 2 133 520HF 0.00 0

0 CLP 13S

-17.07 0.14 0.16 RI3DCLP+

8 2 164 520HF 0.64 20 0

VOL 13S

-12.43 R13DCLP+

Page 7 of 325

TR-151, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A S;/e."

Tb1e M1 eIsan All Indications. U ith Length and Width Outage:

IR14 Tube#

Cal Probe 8

2 164 8

2 164 8

2 164 8

2 164 8

2 164 8

15 50 8

15 50 8

20 29 8

24 29 8

25 30 8

44 12 8

54 73 9

3 113 9

6 113 9

25 30 9

26 29 9

26 29 9

57 69 9

57 69 9

57 69 9

57 69 9

57 69 9

57 69 10 22 64 10 28 29 10 63 73 11 1 64 11 1 115 11 5

50 11 5

50 52OHF 520HF 520HF 520HF 520HF 520HF 520HF 51 OUL 51OUL 51OUL 460PP 51 OUL 540HF 540HF 51OUL 51OUL 51OUL 520HF 520HF 520HF 520HF 520HF 520HF 5 1 OUL 51 OUL 51 OUL 510UL 520HF 520HF 520HF Volt0/ 0 Degrees P 0.00 0

0.00 0

0.11 11 0.36 9

0.00 0

0.77 15 0.00 0

2.65 176 2.09 185 0.35 102 0.00 0

3.78 173 0.31 14 0.37 348 2.49 177 0.55 103 3.58 178 0.00 0

0.30 18 0.00 0

0.54 27 0.34 19 0.00 0

3.18 176 3.41 177 4.39 176 0.16 50 0.50 0

0.64 19 0.00 0

?rigin/

ercent Location Code TSP - Offset 0 CLP 13S 0

CLP 13S 0 VOL 13S 0 VOL 13S 0

CLP 13S 0 VOL ETL 0

CLP ETL 0

DNT LTE 0

INR 01S OD 11 TWD 08S 0

OBS UTE 0 DNT LTE 0 INR 14S 0

INR 15S 0

INR LTE 0

INR 03S 0 DNT LTE 0

CLP ETL 0

VOL ETL 0

CLP ETL ID 58 VOL ETL ID 30 VOL ETL 0

CLP ETL 0

DNT LTE 0

DNT LTE 0 DNT LTE 0

NQI OSS ID 7

TWD 08S ID 30 VOL ETL 0

CLP ETL

-12.43

-7.99

-7.99

-3.62

-3.62

-0.78

-0.78 10.41 28.86 0.65 0.00 10.98 2.27 21.55 10.29 11.74 10.39

-1.65

-1.65 1.93 1.93 2.50 2.50 10.18 10.09 10.02 0.64 0.70 2.77 2.77 Axial Circ Dataset 0.18 0.22 R13DCLP+

0.09 0.11 R13DCLP+

R13DCLP+

SpecInt 0.13 0.17 SpecInt KEXP_+Pt 0.17 0.15 KEXP_+Pt 510_Bobbi 510 Bobbi 510_Bobbi PlugMRP 510_Bobbi 540_Bobbi 540_Bobbi 510 Bobbi 510 Bobbi 510 Bobbi 0.11 0.14 KEXP_+Pt KEXP_+Pt 0.22 0.33 KEXP_+Pt KEXP_+Pt KEXP_+Pt 0.11 0.19 KEXP_+Pt 510 Bobbi 510 Bobbi 510_Bobbi 510 Bobbi Spec lnt KEXP_+Pt 0.11 0.15 KEXP -+Pt Page 8 of 325

TR-151, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A Site:

Three Mile Island All Indicatiions. With Length and 14'iidth Outage:

]1R-A Tube#

Cal Probe 11 7

50 11 7

50 11 7

50 11 7 50 11 21 115 11 21 63 11 24 64 11 24 64 11 25 50 11 25 50 11 25 63 11 28 30 11 29 29 11 29 29 11 45 29 11 45 160 11 60 76 11 61 73 12 51 73 12 51 110 12 51 113 12 51 110 12 51 113 12 52 76 12 52 113 12 61 73 12 63 73 12 68 76 12 71 73 12 71 113 13 1 117 520HF 520HF 520HF 520HF 520HF 51 OUL 510UL 51 OUL 520HF 520HF 51OUL 51OUL 51OUL 51OUL 51OUL 520HF 51OUL 51OUL 51OUL 540HF 520HF 540HF 520HF 51OUL 520HF 51OUL 51OUL 51OUL 510UL 520HF 540HF Volt / Origin!

Degrees Percent Location Code TSP - Offset 0.41 17 ID 25 VOL ETL 0.00 0

0.00 0

0.36 16 0.42 0

0.30 59 0.42 91 3.11 171 0.22 17 0.00 0

4.47 178 3.40 171 0.60 56 3.75 174 0.39 96 0.00 0

6.60 175 6.10 178 1.32 5

1.27 4

0.00 0

0.41 8

0.00 0

0.17 87 0.00 0

5.09 177 6.27 178 6.48 174 0.12 97 0.00 0

0.49 4

0 CLP ETL 0

CLP ETL ID 29 VOL ETL ID 5

TWD 08S 0

NQI 08S OD 12 TWD 08S 0

DNT LTE ID 25 VOL ETL 0

CLP ETL 0

DNT LTE 0

DNT LTE 0

INR 12S 0

DNT LTE 0

NQI LTE 0

NDF LTS 0

DNT LTE 0

DNT LTE ID 17 TWD 12S 0

INR 12S 0 RIC 12S ID 27 TWD 12S 0 NDF 13S 0 NQI 03S 0 NDF 04S 0 DNT LTE 0 DNT LTE 0 DNT LTE 0

NQI 01S 0 NDF 01S 0 INR US 1.75 1.75 2.50 2.50 0.61 0.66

-0.84 9.91 2.72 2.72 10.10 10.27 8.78 10.42 13.83

-10.17 8.68 8.18 11.67 11.67 26.69 26.69

-10.31 21.26

-18.74 10.85 8.69 11.06 10.27 10.27 35.68 Axial Circ Dataset KEXP +Pt 0.20 0.17 KEXP_+Pt 0.11 0.15 KEXP_+Pt KEXP_+Pt SpecInt 510 Bobbi 510_Bobbi 510 Bobbi KEXP_+Pt 0.11 0.15 KEXP_+Pt 510_Bobbi 510_Bobbi 510 Bobbi 510_Bobbi 510_Bobbi SpecInt 510 Bobbi 510_Bobbi 510 Bobbi 540_BobEx Spec mnt 540_BobEx Spec5 Bt 510_Bobbi Spec mnt 510 Bobbi 510_Bobbi 510_Bobbi 510 Bobbi SpecInt 540 Bobbi Page 9 of 325

TR-151, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A Site:

Three Mile Island

.ll Indications. 14'ith Length and Width Outage:

IR14 Tube#

Cal Probe 1 117 1 117 1 121 1 121 1 121 1 121 1 121 1 121 1 121 1 121 1 121 1 121 1 121 1 121 13 38 29 13 42 29 13 42 160 13 60 12 13 64 73 13 64 73 13 67 70 13 67 70 13 67 70 14 3

64 14 5

64 14 17 46 14 17 46 14 21 46 14 21 46 14 32 56 14 32 56 14 36 56 14 36 56 13 13 13 13 13 13 13 13 13 13 13 13 13 13 Volt / Origin/

Degrees Percent 0.77 0,52 0.90 0.00 0.91 0.00 0.61 0.00 0.35 0.00 0.00 0.44 0.00 0.19 7

9 28 0

22 0

22 0

25 0

0 16 0

6 540HF 540HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 51OUL 51OUL 520HF 460PP 510UL 51OUL 520HF 520HF 520HF 51OUL 51OUL 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF ID ID Location Code TSP - Offset 23 30 0

0 0

0 0

0 0

0 0

0 0

0 TWD TWD VOL CLP VOL CLP VOL CLP VOL CLP CLP VOL CLP VOL 13S 13S 14S 14S 14S 14S 14S 14S 14S 14S 14S 14S 14S 14S 0 INR LTS 0 NQI 09S OD 4 TWD 09S 22.29 23.19

-13.67

-13.67

-12.75

-12.75

-8.96

-8.96

-5.61

-5.61

-3.08

-3.08

-1.45

-1.45 0.02 0.17 0.29 0

OBS UTE 0.00 0

DNT LTE 0

DNT LTE ID 0

71 0

INR ETL VOL ETL CLP ETL 8.11 10.55

-2.55 2.38 2.38 0

DNT LTE 10.84 0

INR LTS 0

CLP ETL 0 VOL ETL ID 43 VOL ETL 0 CLP ETL ID 36 VOL ETL 0

CLP ETL ID 47 VOL ETL 0

CLP ETL 38.32

-1.84

-1.84 0.60 0.60 0.43 0.43 1.46 1.46 Axial Cire Dataset 540 Bobbi 540 Bobbi R13DCLP+

0.14 0.17 R13DCLP+

R13DCLP+

0.14 0.17 R13DCLP+

R13DCLP+

0.09 0.17 R13DCLP+

R13DCLP+

0.09 0.17 R13DCLP+

0.09 0.11 R13DCLP+

R13DCLP+

0.09 0.11 R13DCLP+

R13DCLP+

510 Bobbi 510 Bobbi SpecInt PlugMRP 510 Bobbi 510 Bobbi KEXP_+Pt KEXP_+Pt 0.12 0.17 KEXP_+Pt 510_Bobbi 510 Bobbi 0.12 0.14 KEXP_+Pt KEXP_+Pt KEXP_+Pt 0.17 0.19 KEXP_+Pt KEXP_+Pt 0.11 0.10 KEXP_+Pt KEXP_+Pt 0.17 0.15 KEXP +Pt Page 10 of 325 0.73 84 0.16 59 0.23 282 0.00 0

6.38 175 5.51 176 0.11 2

1.21 30 0.00 0

4.29 170 2.43 179 0.00 0

0.18 24 0.64 23 0.00 0

0.51 21 0.00 0

0.49 24 0.00 90

TR-151, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A Site:

Three Mile Island 411 Inclications, uith Length and JWidth Owtaze:

1R14 Tube#

Cal Probe 14 37 55 37 55 59 73 59 113 63 73 64 76 25 64 28 63 41 113 51 79 51 79 67 73 67 113 67 73 68 76 77 110 77 113 77 110 77 110 77 110 77 110 77 113 77 113 77 113 77 113 77 113 77 113 2 117 5

42 5

42 17 63 17 115 52011.I7 520HF 510UL 520HF 51OUL 51OUL 51OUL 51OUL 540HF 520HF 520HF 51OUL 520HF 51OUL 51OUL 540HF 520HF 540HF 540HF 540HF 540HF 520HF 520HF 520HF 520HF 520HF 520HF 540HF 520HF 520HF 51OUL 520HF Volt / Origin/

Degrees Percent Location Code TSP - Offset Axial Circ 0.33 18 ID 27 VOL ETL 0.23 0.00 0

0.19 100 0.57 128 5.45 176 6.85 175 0.14 45 0.56 107 0.65 85 0.21 21 0.00 0

0.59 77 0.00 0

6.15 174 6.00 176 0.28 8

0.00 0

0.42 7

0.42 8

0.37 10 0.48 7

0.00 0

0.00 0

0.38 7

0.00 0

0.00 0

0.35 22 0.47 1

0.53 21 0.00 0

0.80 82 0.00 0

0 CLP ETL 0

NQI 05S OD 11 TWD 05S 0 DNT LTE 0 DNT LTE 0

1NR 12S 0

INR LTE OD 13 TWD 05S 0

VOL ETL 0

CLP ETL 0 NQI LTE 0 NDF LTE 0

DNT LTE 0 DNT LTE 0

BVC 12S 0 NDF 12S ID 23 TWD 12S ID 27 TWD 12S 0

BVC 12S ID 23 TWD 12S 0

NDF 13S 0

CLP 13S 0

VOL 13S 0

NDF 13S 0

CLP 13S 0

VOL 13S 0

INR 15S 0

VOL ETL 0

CLP ETL 0

ADI 08S 0

NDF 08S 0.23

-0.77

-0.69 11.05 10.97 13.65 8.31 0.62

-2.60

-2.60 2.90 2.90 10.86 11.10 16.87 16.87 18.57 24.27 27.52 30.53

-18.43

-12.76

-12.76

-9.48

-6.47

-6.47 42.13

-0.20

-0.20 19.28 19.28 Dataset KEXP_+Pt 0.25 0.17 KEXP_+Pt 510_Bobbi Speclnt 510_Bobbi 510_Bobbi 510 Bobbi 510_Bobbi 540_Bobbi R13DCLP+

0.11 0.10 R13DCLP+

510 Bobbi SpecInt 510_Bobbi 510 Bobbi 540_Bobbi SpecInt 540_Bobbi 540_Bobbi 540_Bobbi 540_Bobbi SpecInt 0.09 0.11 Spec lnt SpecInt RI3DCLP+

0.14 0.17 SpecInt SpecInt 540 Bobbi KEXP_+Pt 0.20 0.17 KEXP_+Pt 510_Bobbi Specmt Page 11 of 325

TR-151, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A Si.e:

Three Mile Island

.41 Ihdicwaions, With Length and I'Vidth Outage:

]R14 Volt/ Origin!

Degrees Percent 0.00 0

Tube#

16 19 1.6 16 41 30 16 81 73 17 26 63 17 26 133 17 32 63 17 35 55 17 35 55 17 35 55 17 35 55 17 36 29 17 40 79 17 40 79 17 42 29 17 44 29 17 44 160 17 48 29 17 48 160 17 56 12 17 60 79 17 60 79 17 69 73 17 69 73 17 69 113 17 72 113 17 72 76 17 81 70 17 81 70 17 81 70 17 81 70 17 81 70 Cal Location Code TSP - Offset Probe 510UL 51OUL 51OUL 520HF 51OUL 520HF 520HF 520HF 520HF 510UL 520HF 520HF 51OUL 51OUL 520HF 51OUL 520HF 460PP 520HF 520HF 51OUL 51OUL 520HF 520HF 51 OUL 520HF 520HF 520HF 520HF 520HF 0.15 0.18 0.61 0.00 0.58 0.31 0.00 0.27 0.00 0.23 0.00 0.38 0.19 0.32 0.00 0.54 0.00 0.00 0.41 0.00 0.85 6.44 0.00 0.32 0.21 0.00 0.77 0.73 0.00 1.25 Axial Circ Dataset 64 88 174 0

70 9

0 10 0

106 0

35 106 82 0

92 0

0 2

0 96 176 0

107 75 0

23 21 0

27 Page 12 of 325 0

OBS UTE 0

INR 07S OD 5

TWD 13S 0 INR 08S 0 NDF 09S 0

INR LTE 0

VOL ETL 0

CLP ETL ID 9 VOL ETL 0

CLP ETL OD 4 TWD 09S 0

CLP ETL 0

VOL ETL 0

INR LTE 0

NQI LTE 0

NDF LTS 0

NQI LTE 0

NDF LTS 0

OBS UTE 0

VOL ETL 0

CLP ETL 0

NQI LTE 0

DNT LTE 0

NDF LTS OD 6

TWD 08S 0

NQI 08S 0

CLP ETL 0

VOL ETL ID 36 VOL ETL 0

CLP ETL ID 58 VOL ETL 0.00 16.59 0.13 29.51

-9.33 3.48

-0.79

-0.79 0.77 0.77

-0.76

-1.62

-1.62 20.90 20.97

-3.03 9.94

-14.06 0.00

-1.42

-1.42 3.48 10.80

-20.52 0.67 0.68

-0.50

-0.50 0.18 0.18 3.15 Plug_MRP 510 Bobbi 510_Bobbi 510 Bobbi R 13DCLP+

510_Bobbi KEXP_+Pt 0.11 0.12 KEXP_+Pt KEXP_+Pt 0.17 0.10 KEXP-+Pt 510 Bobbi 0.11 0.09 R13DCLP+

R13DCLP+

510_Bobbi 510_Bobbi SpecInt 510_Bobbi SpecInt PlugMRP RI 3DCLP+

0.17 0.14 R13DCLP+

510 Bobbi 510 Bobbi SpecInt SpecInt 510 Bobbi 0.18 0.18 KEXP_+Pt KEXP +Pt KEXP -- Pt 0.18 0.27 KEXP_+Pt KEXP +Pt

TR-151, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A S'i!."

Three Mile Island All Indicauions, 1'ith Length anld 4'idthI Outage:

1R14 Tube#

Cal Probe 17 81 70 17 81 70 17 81 70 17 82 110 17 82 113 17 82 113 1 110 1 110 1 117 1 110 1 110 18 2

3 3 121 3 121 3 121 3 121 3 121 3 117 3 121 3 121 18 4

42 18 4

42 18 10 63 18 10 115 18 31 45 18 31 45 18 50 55 18 50 55 18 60 70 18 60 70 18 60 70 18 60 70 18 60 70 18 60 70 18 74 113 52 0HF1T" 520HF 520HF 540HF 520HF 520HF 520HF 520HF 540HF 520HF 520HF 51 OUL 520HF 520HF 520HF 520HF 520HF 540HF 520HF 520HF 520HF 520HF 51OUL 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF Volt / Origin/

Degrees Percent 0.0A n

1.00 20 0.00 0

0.35 8

0.22 10 0.00 0

0.00 0.38 0.42 0.00 0.58 0

15 11 0

16 0.20 84 0.19 0.00 0.16 0.00 0.00 0.37 0.00 0.74 12 0

24 0

0 10 0

30 0.41 24 0.00 27 0.19 90 0.42 0

0.49 20 0.00 0

Location Code TSP - Offset 0

CLP ETL ID 20 VOL ETL 0

CLP ETL 0 BVC 15S 0

VOL 15S 0

CLP 15S 0

CLP 04S 0

VOL 04S ID 37 TWD 04S 0

CLP 04S 0

VOL 04S 0

INR 13S 0

VOL 15S 0

CLP 15S 0

VOL 15S 0

CLP 15S 0

NDF 15S ID 33 TWD 15S 0

CLP UTS 0

VOL UTS ID 47 SCI ETL 0

ARC ETL 0

NQI 13S ID 6

TWD 13S 0 VOL ETL 0

CLP ETL 0.00 0

0 CLP ETL 0.58 22 ID 40 VOL ETL 0.28 18 0

VOL ETL 0.00 0

0 CLP ETL 0.52 31 ID 76 VOL ETL 0.00 0

0 CLP ETL 0.80 25 ID 51 VOL ETL 0.00 0

0 CLP ETL 0.61 118 OD 11 TWD 08S 3.15 3.20 3.20 5.49 5.71 5.71 4.72 4.72 5.20 5.34 5.34

-0.80 18.76 18.76 23.57 23.57 24.77 24.77

-21.90

-21.90 0.63 0.63

-0.84

-0.78

-0.16

-0.16 0.30 0.30

-0.42

-0.42 1.45 1.45 3.51 3.51 0.46 Axial Circ Dataset 0.41 0.47 KEXP +Pt KEXP +Pt 0.15 0.16 KEXP-+Pt 540_Bobbi SpecInt 0.14 0.17 SpecInt 0.09 0.11 SpecInt SpecInt 540_Bobbi 0.14 0.17 Spec Int SpecInt 510 Bobbi R13DCLP+

0.09 0.11 R13DCLP+

R13DCLP+

0.09 0.11 R13DCLP+

R 13DCLP+

540_Bobbi 0.14 0.16 RI3DCLP+

R13DCLP+

KEXP_+Pt 0.15 KEXP-+Pt 510 Bobbi SpecInt KEXP-+Pt 0.11 0.12 KEXP_+Pt 0.17 0.20 KEXP_+Pt KEXP_+Pt KEXP-+Pt 0.18 0.14 KEXP-+Pt KEXP +Pt 0.18 0.18 KEXP-+Pt KEXP-+Pt 0.18 0.18 KEXP-+Pt Spec lnt Page 13 of 325 18 18 18 18 18 18 18 18 18 18 18 18 18

TR-151, Revision 0 Appendix II Recordable Indications Component":

TMI-OTSG-A Site:

Three Mile Island All Indications. 117th Length and Width Outage:

I RI 4 Volt / Origin/

Location Tube#

Cal Probe Degrees Percent Code TSP - Offset Axial Circ Dataset 18 74 76 510UL 0.23 59 0

05

.6 510 Bobbi 18 79 73 51OUL 0.39 83 OD 10 TWD 08S 0.59 510 Bobbi 19 1 117 540HF 0.33 10 ID 33 TWD 05S 31.90 540_Bobbi 19 1 121 520HF 0.49 27 0 VOL 06S

-5.05 R13DCLP+

19 1 121 520HF 0.00 0

0 CLP 06S

-5.05 0.14 0.17 RI3DCLP+

19 82 12 460PP 0.60 132 0

COD UTE

-1.76 PlugMRP 19 83 73 51OUL 2.60 173 0

DNT LTE 10.96 510_Bobbi 19 84 113 520HF 0.00 0

0 NDF 10S 0.38 SpecInt 19 84 73 5IOUL 0.14 86 0

NQI 10S 0.38 510_Bobbi 19 85 70 520HF 0.00 0

0 CLP ETL 1.48 0.11 0.14 KEXP_+Pt 19 85 70 520HF 0.69 24 ID 47 VOL ETL 1.48 KEXP_+Pt 19 85 70 520HF 0.00 0

0 CLP ETL 1.88 0.17 0.19 KEXP_+Pt 19 85 70 520HF 0.53 17 ID 25 VOL ETL 1.88 KEXP_+Pt 19 85 70 520HF 5.98 45 OD 96 SCI ETL 2.94 KEXP_+Pt 19 85 70 520HF 0.00 40 0 ARC ETL 2.94 0.22 KEXP_+Pt 20 1 117 540HF 0.41 6

ID 20 TWD 05S 32.05 540_Bobbi 20 1 133 520HF 1.02 19 0 VOL 06S

-5.03 R13DCLP+

20 1 133 520HF 0.00 0

0 CLP 06S

-5.03 0.21 0.16 RI3DCLP+

20 1 121 520HF 0.61 22 0

VOL 08S

-4.84 R13DCLP+

20 1 121 520HF 0.00 0

0 CLP 08S

-4.84 0.14 0.17 R13DCLP+

20 9

42 520HF 0.16 16 0

VOL ETL

-0.73 KEXP_+Pt 20 9

42 520HF 0.00 0

0 CLP ETL

-0.73 0.06 0.10 KEXP_+Pt 20 9

42 520HF 0.00 0

0 CLP ETL 0.10 0.11 0.10 KEXP_+Pt 20 9

42 520HF 0.22 12 ID 13 VOL ETL 0.10 KEXP_+Pt 20 9

42 520HF 0.32 17 ID 25 VOL ETL 2.30 KEXP_+Pt 20 9

42 520HF 0.00 0

0 CLP ETL 2.30 0.11 0.15 KEXP_+Pt 20 9

42 520HF 0.00 0

0 CLP ETL 2.96 0.11 0.15 KEXP_+Pt 20 9

42 520HF 0.38 14 ID 17 VOL ETL 2.96 KEXP_+Pt 20 33 115 520HF 0.00 0

0 NDF 14S 14.18 SpecInt 20 33 113 540HF 0.60 5

ID 17 TWD 14S 14.18 540_Bobbi 20 41 113 540HF 0.24 358 0 INR 09S 12.70 540_Bobbi 20 41 160 520HF 0.00 0

0 NDF 11S 15.30 SpecInt 20 41 113 540HF 0.34 12 0

BVC 11S 15.30 540_Bobbi 20 51 56 520HF 0.00 0

0 CLP ETL 0.05 0.11 0.15 KEXP+ Pt Page 14 of 325

TR-151, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A Site:

Three N4i1. Island

.11 Indications, I'ith Length and 1+7dth Outage:

1R!4 Volt / Origin/

Degrees Percent Tube#

51 56 51 56 51 56 56 110 56 123 56 123 Cal 20 20 20 20 20 20 ID ID ID ID Location Code TSP - Offset 47 22 0

20 0

0 VOL VOL CLP TWD VOL CLP ETL ETL ETL 15S UTS UTS 0

VOL ETL 0

CLP ETL 0

CLP ETL 47 VOL ETL Probe 520HF 520HF 520HF 540HF 520HF 520HF 520HF 520HF 520HF 520HF 51OUL 460PP 51OUL 5201F 520HF 51OUL 520HF 51 0UL 520HF 520HF 540HF 540HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 0.05 0.24 0.24 33.68

-13.21

-13.21

-1.42

-1.42 2.34 2.34 5.93

-0.19

-0.23 2.02 2.02 Axial Circ Dataset KEXP +Pt KEXP +Pt 0.11 0.15 KEXP_+Pt 540 Bobbi R13DCLP+

0.19 0.16 R13DCLP+

KEXP_+Pt 0.17 0.14 KEXP_+Pt 0.11 0.14 KEXP_+Pt KEXP_+Pt 510_Bobbi PlugMRP 510_Bobbi 0.16 0.23 KEXP_+Pt KEXP_+Pt 0.31 24 0.29 16 0.00 0

0.41 6

0.27 15 0.00 0

0.32 23 0.00 0

0.00 0

0.23 24 0.44 98 0.61 128 0.09 134 0.00 0

0.59 22 2.36 173 0.00 0

0.16 69 0.23 19 0.00 0

0 VOL ETL 0

CLP ETL 0

ID 20 0

0 0

0 0

0 0

0 0

0 0

0 INR TWD CLP VOL RIC RIC VOL CLP RIC CLP VOL VOL CLP VOL 14S 15S ETL ETL UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS 20 57 70 20 57 70 20 62 69 20 62 69 20 63 78 20 70 12 20 75 73 20 83 73 20 83 73 22 1

4 22 2 110 22 2

4 22 29 79 22 29 79 510_Bobbi SpecInt 510 Bobbi R13DCLP+

0.12 0.09 R13DCLP+

540_Bobbi 540_Bobbi 0.12 0.14 R13DCLP+

RI3DCLP+

RI 3DCLP+

RI3DCLP+

R13DCLP+

0.10 0.11 R13DCLP+

R13DCLP+

0.15 0.11 R13DCLP+

R13DCLP+

R13DCLP+

0.11 0.09 RI3DCLP+

R13DCLP+

Page 15 of 325 5

6 0

26 0

0 15 0

0 0

22 20 0

16 0

WNR 13S 0

AOD UTE 0

rNR 07S 0

CLP ETL ID 40 VOL ETL 0

INR LTE 11.05 0

NDF 15S 6.78 0

NQI 15S 6.78

-1.10

-1.10 16.62 33.76

-3.50

-3.50

-14.95

-13.66

-12.93

-12.93

-12.86

-5.14

-5.14

-5.02

-5.02 3.99 0.26 0.89 0.00 0.38 0.00 0.00 0.50 0.00 0.00 0.00 0.24 0.12 0.00 0.49 22 22 22 22 22 22 22 22 22 22 22 22 22 22 35 113 35 113 35 79 35 79 35 79 35 79 35 133 35 133 35 79 35 133 35 133 35 79 35 79 35 133

TR-151, Revision 0 Appendix II Recordable Indications Co0ponent":

TMI-OTSG-A Site.

Three Mile Island All Indications, WJith Length and J'cldth Outage:

1R14 V'olt / Origin!

Degrees Percent 0.00 0

Tube#

22 35 133 22 35 113 22 46 35 22 50 55 22 50 55 22 50 55 22 50 55 22 52 35 22 70 78 22 77 12 22 88 78 22 88 78 22 88 113 22 90 105 22 90 156 22 90 105 23 9

4 23 15 45 23 15 45 23 18 64 23 25 63 23 26 113 23 26 133 23 26 133 23 33 45 23 33 45 23 38 46 23 38 46 23 38 46 23 38 46 23 45 55 Cal Probe 420-IF 540HF 51OUL 520HF 520HF 520HF 520HF 510UL 51OUL 460PP 51OUL 51OUL 520HF 51OUL 520HF 51OUL 51OUL 520HF 520HF 51OUL 510UL 540HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF Location Code TSP - Offset 0.42 0.31 0.38 0.00 0.52 0.00 3.33 0.18 0.70 3.41 0.19 0.00 0.19 0.00 2.94 0.15 0.62 0.00 2.46 2.30 0.42 0.42 0.00 0.52 0.00 0.59 0.00 0.00 0.37 0.41 9

56 21 0

26 0

15 100 122 172 91 0

105 0

179 105 23 27 178 185 6

6 0

22 0

26 0

0 18 22 Axial Circ Dataset ID 3

OD ID ID ID ID ID Page 16 of 325 0

CLP UTS 0

TWD UTS 6

TWD 08S 0

VOL ETL 0

CLP ETL 0

VOL ETL 0

CLP ETL 0 INR LTE 0 INR UTS 0 AOD UTE 0

DNT LTE 0 NQI LTE 0 NDF LTS 0 NQI 14S 0 NDF 15S 0

DNT LTE 0

INR LTE 40 SCI ETL 0 ARC ETL 0

INR 07S 0 INR LTS 20 TWD 15S 0

VOL UTS 0

CLP UTS 0

VOL ETL 0

CLP ETL 54 VOL ETL 0

CLP ETL 0

CLP ETL 18 VOL ETL 40 VOL ETL 3.99 4.02 0.70

-1.55

-1.55

-0.09

-0.09 1.77 0.33

-0.26 10.80 15.23

-8.77 33.19

-1.81 11.46 17.00 0.96 0.96 15.14 6.51 32.28

-13.60

-13.60

-1.00

-1.00 2.02 2.02 2.71 2.71 2.55 0.10 0.16 Ri3DCLP+

540_Bobbi 510 Bobbi KEXP-+Pt 0.22 0.18 KEXP-+Pt KEXP_+Pt 0.11 0.24 KEXP_+Pt 510 Bobbi 510 Bobbi PlugMRP 510_Bobbi 510_Bobbi Speclnt 510_Bobbi Spec Int 510 Bobbi 510_Bobbi KEXP_+Pt 0.14 KEXP_+Pt 510_Bobbi 510 Bobbi 540_Bobbi R13DCLP+

0.14 0.16 R13DCLP+

KEXP +Pt 0.11 0.14 KEXP_+Pt KEXP-+Pt 0.11 0.19 KEXP +Pt 0.11 0.14 KEXP +Pt KEXP +Pt KEXP +Pt

TR-151, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A Site:

Three Mile Island All Indicaitions, With Length and JWidth Outage:

!R14 Volt / Origin/

Degrees Percent V.VV 0

0.00 0

0.38 15 0.17 0.00 0.36 0.00 0.40 0.00 5

0 39 0

20 0

Cal Tube#

23 45 55 23 47 55 23 47 55 Probe 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 51OUL 510UL 51OUL 520HF 51OUL 520HF 510UL 520HF 520HF 520HF 520HF 520HF 520HF 520HF 51OUL 510UL 0

ID 20 0

0 0

0 ID 33 0

0 0

Location Code TSP - Offset 0

CLP ETL 2.5 CLP ETL VOL ETL VOL CLP VOL CLP VOL CLP ETL ETL ETL ETL ETL ETL VOL ETL CLP ETL ID 43 VOL ETL 0

CLP ETL ID 47 0

ID 36 0

0 3.59 174 3.07 185 0.00 0

0.47 91 0.00 0

0.37 88 0.00 0

0.41 0.00 0.61 0.00 24 0

15 0

0.52 21 0.00 0

0.20 99 0.14 104 VOL CLP VOL CLP DNT ETL ETL ETL ETL LTE 0

DNT LTE 0

DNT 01S 0

NDF 01S 0

NQI LTE 0

NDF LTS 0

NQI LTE 0 NDF LTS 0

0 ID 20 0

VOL CLP VOL CLP ETL ETL ETL ETL ID 36 VOL ETL 0

CLP ETL 0

INR LTE 0

INR LTE 0.13 0.13

-1.49

-1.49

-0.09

-0.09 0.26 0.26

-0.10

-0.10 1.38 1.38 0.45 0.45 3.41 3.41 12.20 10.76 5.70 5.70 20.63

-3.37 12.91

-11.09

-0.80

-0.80 2.08 2.08 0.01 0.01 10.42 20.11 Axial Circ Dataset 0.1 i 0.15 KEXP_+Pt 0.17 0.15 KEXP +Pt KEXP-+Pt KEXP +Pt 0.17 0.14 KEXP +Pt KEXP +Pt 0.17 0.14 KEXP +Pt KEXP +Pt 0.17 0.14 KEXP-+Pt KEXP-+Pt 0.17 0.26 KEXP_+Pt KEXP_+Pt 0.17 0.19 KEXP_+Pt KEXP_+Pt 0.21 0.18 KEXP_+Pt KEXP_+Pt 0.21 0.18 KEXP_+Pt 510 Bobbi 510 Bobbi 510 Bobbi Specmnt 510 Bobbi SpecInt 510 Bobbi SpecInt KEXP_+Pt 0.17 0.19 KEXP-+Pt KEXP_+Pt 0.17 0.19 KEXP-+Pt KEXP_+Pt 0.11 0.14 KEXP -+Pt 510_Bobbi 510_Bobbi Page 17 of 325 0.34 0.00 0.44 0.00 4.00 24 0

21 0

171 23 23 23 23 23 23 62 62 62 62 62 62 68 68 68 68 68 68 23 63 69 23 63 69 23 68 70 23 68 70 23 23 23 23 23 90 90 90 90 90 73 73 73 73 105 0.31 31 0.00 0

0.52 23 0.00 0

24 2

3 24 11 4

24 11 110 24 50 36 24 50 160 24 52 36 24 52 160 24 24 24 24 56 56 56 56 55 55 55 55 24 63 68 24 63 68 24 66 77 24 66 77

TR-151, Revision 0 Appendix I1 Recordable Indications Component:

TMI-OTSG-A Site:

Three Mile Island All Indications, With Length antd W,"idth Outage:

1R14 Volt / Origin/

Location Tube#

Cal Probe Degrees Percent Code TSP - Offset Axial Circ Dataset 24 76 79 520HF 0.26 14 0

VOL ETL

-3.28 R13DCLP+

24 76 79 520HF 0.00 0

0 CLP ETL

-3.28 0.12 0.14 R13DCLP+

24 76 68 520HF 0.17 31 0

VOL ETL

-0.62 KEXP_+Pt 24 76 68 520HF 0.00 0

0 CLP ETL

-0.62 0.11 0.14 KEXP_+Pt 24 76 79 520HF 0.34 19 0

PRA ETL

-0.57 R13DCLP+

24 76 68 520HF 1.42 30 ID 71 VOL ETL 1.56 KEXP_+Pt 24 76 68 520HF 0.00 0

0 CLP ETL 1.56 0.17 0.19 KEXP_+Pt 24 76 79 520HF 0.00 0

0 CLP ETL 1.79 0.23 0.24 KEXP_+Pt 24 76 79 520HF 1.28 31 ID 76 VOL ETL 1.79 KEXP_+Pt 24 77 79 520HF 0.00 0

0 CLP ETL

-1.24 0.18 0.18 R13DCLP+

24 77 79 520HF 0.28 38 0

VOL ETL

-1.24 RI3DCLP+

24 78 68 520HF 0.41 12 0

VOL ETL

-0.60 KEXP_+Pt 24 78 68 520HF 0.00 0

0 CLP ETL

-0.60 0.17 0.14 KEXP_+Pt 24 78 68 520HF 0.00 0

0 CLP ETL

-0.10 0.17 0.14 KEXP_+Pt 24 78 68 520HF 0.44 35 0

VOL ETL

-0.10 KEXP_+Pt 24 78 68 520HF 0.20 21 ID 36 VOL ETL 1.36 KEXP_+Pt 24 78 68 520HF 0.00 0

0 CLP ETL 1.36 0.11 0.14 KEXP_+Pt 24 89 78 51OUL 3.84 172 0

DNT LTE 10.66 510 Bobbi 24 90 105 51OUL 4.19 173 0

DNT LTE 10.79 510 Bobbi 24 92 105 51OUL 0.28 94 0

NQI 15S 1.10 510_Bobbi 24 92 156 520HF 0.78 69 0 MB 15S 1.21 Specmnt 24 92 105 51OUL 3.66 170 0 DNT LTE 11.60 510_Bobbi 25 1

4 510UL 0.38 5

ID 17 TWD 12S 3.29 510_Bobbi 25 1 117 540HF 0.38 2

0 INR 12S 3.31 540_BobEx 25 1

4 51OUL 1.04 42 0

INR 13S

-0.75 510_Bobbi 25 1 117 540HF 0.27 59 0 NQI 13S

-0.75 540_BobEx 25 1 110 520HF 0.00 0

0 NDF 13S

-0.75 SpecInt 25 3

3 51OUL 0.13 92 0

INR 02S

-0.75 510_Bobbi 25 14 3

510UL 0.42 40 0

INR LTE 19.50 510 Bobbi 25 23 59 51OUL 0.14 36 0

INR 13S 33.66 510_Bobbi 25 41 36 51OUL 0.09 58 0

INR 1OS 19.91 510_Bobbi 25 41 55 520HF 0.00 0

0 CLP ETL

-0.06 0.17 0.19 KEXP_+Pt 25 41 55 520HF 0.26 29 0

VOL ETL

-0.06 KEXP -Pt Page 18 of 325

TR-151, Revision 0 Appendix I1 Recordable Indications Component:

TMI-OTSG-A Site:

Three Mie TcIlnd

.41 Indications, JI ith Length and Icidth Outage:

1R14 Tube#

Cal Probe 25 42 25 42 25 42 25 42 55 55 55 55 25 48 56 25 48 56 25 64 25 64 25 64 25 64 68 68 68 68 25 65 67 25 65 67 25 70 25 70 25 70 25 70 25 70 25 70 25 70 25 70 25 71 25 71 25 71 25 71 68 68 68 68 68 68 68 68 67 67 67 67 25 79 77 25 87 77 25 89 77 25 94 105 26 5

4 26 6

3 26 9

4 26 9 110 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520UL 51OUL 51OUL 51OUL 51OUL 51OUL 51 OUL 510UL 520HF Volt / Origin/

Degrees Percent 0.49 0.00 0.33 0.00 14 0

15 0

0.51 13 0.00 0

0.16 0.00 0.00 0.48 28 0

0 26 0.22 26 0.00 0

0.00 0

0.19 8

0.31 21 0.00 0

1.17 31 0.00 90 0.00 0

1.66 33 0.33 26 0.00 34 1.02 25 0.00 30 0.52 90 0.16 85 0.32 120 4.69 176 0.26 92 0.19 113 0.11 72 0.00 0

ID 17 0

ID 20 0

Location Code TSP - Offset VOL ETL CLP ETL VOL ETL CLP ETL ID 15 VOL ETL 0

CLP ETL ID 63 0

0 ID 54 VOL ETL CLP ETL CLP ETL VOL ETL ID 54 VOL ETL 0 CLP ETL ID 3

ID 7

ID 8

ID 5

ID 5

0 CLP ETL 0

VOL ETL 6 VOL ETL 0

CLP ETL

'6 VOL ETL 0

CLP ETL 0

CLP ETL 6

VOL ETL 4

SCI ETL 0

ARC ETL 1 MCI ETL 0

ARC ETL 0 INR LTE 0 INR 15S 0 INR 10S 0 DNT LTE 0 INR LTE 0 INR 10S 0 NQI 08S 0

NDF 09S 0.39 0.39 1.19 1.19 1.89 1.89 2.85 2.85 4.30 4.30 1.24 1.24

-0.96

-0.96 0.92 0.92 1.81 1.81 2.86 2.86 1.07 1.07 4.28 4.28 11.00 14.24 5.14 11.24 18.95 7.97 36.74

-2.26 Axial Circ Dataset KEXP_+Pt 0.14 0.17 KEXP +Pt KEXP +Pt 0.17 0.20 KEXP_+Pt KEXP_+Pt 0.17 0.15 KEXP_+Pt KEXP_+Pt 0.17 0.18 KEXP_+Pt 0.17 0.18 KEXP_+Pt KEXP_+Pt KEXP_+Pt 0.11 0.12 KEXP_+Pt 0.14 0.21 KEXP_+Pt KEXP_+Pt KEXP_+Pt 0.11 0.14 KEXP_+Pt KEXP_+Pt 0.17 0.18 KEXP_+Pt 0.17 0.18 KEXP_+Pt KEXP_+Pt KEXP_+Pt 0.18 KEXP_+Pt KEXP_+Pt 0.16 KEXP_+Pt 510_Bobbi 510_Bobbi 510 Bobbi 510 Bobbi 510 Bobbi 510_Bobbi 510_Bobbi SpecInt Page 19 of 325

TR-151, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A

.Site:"

Three Mile Island All Indications, Wl'ith Length and WI'Tdth Outage:.

!R14 Tubeg Cal Probe 26 "8 45 26 38 45 26 92 79 26 92 79 26 96 167 26 96 108 26 96 156 26 96 108 26 96 167 26 96 108 26 96 108 26 96 167 27 2

79 27 2

79 27 6 110 27 6

4 27 6

4 27 6 110 27 23 58 27 42 27 42 27 42 27 42 5 T T 520HF 520HF 520HF 540HF 520HF 540HF 520HF 540HF 540HF 520HF 520HF 520HF 520HF 51OUL 51OUL 520HF 51OUL 520HF 520HF 520HF 520HF 460PP 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 55 55 55 55 27 45 8

27 47 27 47 27 47 27 47 27 47 27 47 27 52 27 52 27 52 27 52 27 52 55 55 55 55 55 55 79 79 79 79 79

'oltt/ Origin!

Degrees Percent 0.48 29 0.00 0

0.36 29 0.00 0

0.00 0.18 0.00 0.30 0.00 0.25 5.24 0.00 0

97 0

6 0

11 176 0

Location Code TSP - Offset 0 VOL ETL 0

CLP ETL 0

VOL ETL 0

CLP ETL 0

0 0

0 0

0 0

0 0.38 18 0.00 0

0.00 0.20 0.15 0.00 NDF 15S NQI 15S NDF 15S BVC 15S NDF 15S BVC 15S DNT LTE NDF UTS 0

VOL ETL 0

CLP ETL 0

98 111 0

0 0

0 0

0.63 97 0.00 0.71 0.33 0.00 0

27 26 0

NDF 05S NQI 05S NQI 09S NDF 10S

-0.23

-0.23

-1.12

-1.12 1.28 1.28 1.28 19.40 19.53 35.06 11.12

-10.93

-1.69

-1.69 11.72 11.72 33.13

-6.87 0 INR LTE 8.01 0

0 ID 54 0

0.00 0

0.00 0.61 0.42 0.00 0.00 0.38 0.00 0.10 0.13 0.00 0.19 0

16 16 0

0 12 0

4 19 0

4 CLP ETL VOL ETL VOL ETL CLP ETL

-0.19

-0.19 0.81 0.81 0

OBS UTE 0.00 0

0 ID 22 0

0 ID 13 0

0 0

0 0

CLP ETL VOL ETL VOL ETL CLP ETL CLP ETL VOL ETL CLP ETL VOL ETL VOL ETL CLP ETL VOL ETL

-0.68

-0.68 0.71 0.71 3.88 3.88

-2.82

-2.82

-1.96

-1.96

-1.84 Axial Circ Dataset KEXP +Pt 0.14 0.14 KEXP_+Pt RI 3DCLP+

0.24 0.18 R13DCLP+

Spec Int 540_Bobbi SpecInt 540_Bobbi R13DCLP+

540_Bobbi 540_Bobbi R13DCLP+

R13DCLP+

0.18 0.23 R13DCLP+

SpecInt 510 Bobbi 510_Bobbi SpecInt 510_Bobbi 0.15 0.15 KEXP_+Pt KEXP_+Pt KEXP_+Pt 0.20 0.17 KEXP_+Pt Plug_MRP 0.17 0.19 KEXP_+Pt KEXP_+Pt KEXP_+Pt 0.20 0.12 KEXP_+Pt 0.15 0.15 KEXP_+Pt KEXP +Pt 0.11 0.14 RI3DCLP+

RI 3DCLP+

RI 3DCLP+

0.11 0.14 R13DCLP+

R13DCLP+

Page 20 of 325

TR-151, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A Site.

Three Mile Island All hIdications, I' ith Length and Width Outage:

1R14 Volt / Origin!

Degrees Percent 0.00 0

0 0.53 32 ID 86 0.00 0

0 0.47 174 0

0.26 18 0.00 0

Cal Tube#

52 79 52 79 52 79 52 79 27 27 27 27 Probe 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 540HF 540HF 540HF 520HF 520HF 520HF 520HF 51OUL 51OUL 51 OUL 520HF 520HF 520HF 520HF 520HF 520HF 51 OUL 520HF 520HF 0

0 0

0 0

0 0

0 0

0 ID 17 0

0 0

0 0

0 Code CLP VOL CLP INR Location TSP - Offset TI_..1

-I.84 ETL 0.66 ETL 0.66 ETL 4.40 0

VOL ETL 0

CLP ETL CLP VOL CLP VOL VOL CLP CLP VOL CLP VOL TWD DNT INR CLP VOL VOL CLP ETL ETL ETL ETL ETL ETL ETL ETL UTS UTS 15S LTE LTE UTS UTS UTS UTS 0

1NR 10S 0

DNT LTE 0

NQI 10S 0

NDF 10S 0

CLP ETL 0

VOL ETL ID 54 VOL ETL 0

CLP ETL 0 NDF 06S 0

DNT 06S 0

VOL ETL 0

CLP ETL

-1.93

-1.93

-2.63

-2.63

-2.01

-2.01

-6.50

-6.50

-4.49

-4.49

-0.83

-0.83 37.44 10.66 21.81

-9.73

-9.73

-8.73

-8.73

-0.28 10.57 11.35 11.35

-2.25

-2.25 2.48 2.48 10.76 10.76

-2.57

-2.57 Axial Circ Dataset 0.i7 0.14 R13DCLP+

Rl3DCLP+

0.12 0.18 R13DCLP+

R13DCLP+

R13DCLP+

0.11 0.19 R13DCLP+

0.18 0.18 R13DCLP+

R13DCLP+

0.12 0.18 R13DCLP+

R13DCLP+

R13DCLP+

0.12 0.14 R13DCLP+

0.12 0.14 R13DCLP+

R13DCLP+

0.12 0.14 R13DCLP+

R 13DCLP+

540_Bobbi 540 Bobbi 540 Bobbi 0.15 0.12 Spec Int Spec Int Spec Int 0.10 0.12 SpecInt 510_Bobbi 510_Bobbi 510 Bobbi SpecInt 0.17 0.15 KEXP_+Pt KEXP_+Pt KEXP_+Pt 0.12 0.14 KEXP_+Pt Spec Int 510 Bobbi KEXP-+Pt 0.17 0.15 KEXP -+-Pt Page 21 of 325 0

34 0

23 14 0

0 24 0

20 5

175 63 0

20 7

0 0.21 119 3.82 171 0.15 104 0.00 0

0.00 0

0.25 10 0.32 26 0.00 0

0.00 0

3.42 186 0.26 6

0.00 0

27 55 79 27 55 79 71 71 71 71 79 79 79 79 79 79 79 79 79 79 79 79 79 79 79 79 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 0.00 0.72 0.00 0.15 0.30 0.00 0.00 0.18 0.00 0.37 0.49 3.12 0.92 0.00 0.41 0.13 0.00 96 108 96 108 96 108 96 156 96 156 96 156 96 156 27 97 105 27 97 105 28 6

4 28 6 110 28 32 50 28 32 50 28 33 51 28 33 51 28 52 160 28 52 37 28 55 56 28 55 56

TR-15 1., Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A Site:

Three Mile island All hindications. W'ith Length and 1,'/thb Outage:

1R14 Tube#

Cal Probe 28 55 56 28 55 56 28 55 56 28 55 56 28 55 56 28 55 56 28 55 56 28 55 56 28 73 68 28 73 68 28 77 68 28 77 68 28 80 67 28 80 67 28 81 81 28 92 79 28 92 79 28 93 105 28 97 106 28 99 105 29 8

42 29 36 50 29 36 50 29 36 50 29 36 50 29 38 59 29 38 115 29 64 81 29 80 79 29 80 79 29 80 79 29 80 79 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 51OUL 520HF 520HF 51OUL 51OUL 51OUL 520HF 520HF 520HF 520HF 520HF 51OUL 520HF 51OUL 520HF 520HF 520HF 520HF Volt / Origin!

Degrees Percent 0.30 8

0.00 0.53 0.00 0.35 0.00 0.27 0.00 0.24 0.00 0.00 0.44 0.00 0.25 0.37 0.00 0.37 0.40 0.42 2.92 0.06 0.19 0.00 0.70 0.00 0.40 1.58 0.17 0.29 0.00 0

18 0

24 0

16 0

16 0

0 27 0

14 88 0

25 131 120 174 229 27 0

20 0

64 0

106 26 0

ID ID ID ID ID ID OD ID ID Location Code TSP - Offset 0 VOL ETL 0 CLP ETL 27 VOL ETL 0

CLP ETL 47 VOL ETL 0

CLP ETL 22 VOL ETL 0

CLP ETL 22 VOL ETL 0

CLP ETL 0

CLP ETL 58 VOL ETL 0

CLP ETL 17 VOL ETL 7

TWD 09S 0

CLP ETL 0

VOL ETL 0

INR 10S 0

INR 15S 0

DNT LTE 0

INR ETL 0 VOL ETL 0

CLP ETL 33 VOL ETL 0

CLP ETL 0 NQI 08S 17 TWD 08S 0

INR LTE 0

VOL ETL 0

CLP ETL

-0.06

-0.06 0.82 0.82 3.59 3.59 4.85 4.85 1.41 1.41 0.06 0.06 2.65 2.65

-0.84

-1.25

-1.25 12.03

-0.15 10.60

-0.18

-0.73

-0.73 0.79 0.79 0.66 0.82 11.69

-2.60

-2.60 0.24 23 ID 22 VOL ETL 2.41 0.00 0

0 CLP ETL 2.41 Axial Circ Dataset KEXP +Pt 0.11 0.10 KEXP +Pt KEXP +Pt 0.11 0.15 KEXP +Pt KEXP +Pt 0.11 0.15 KEXP +Pt KEXP +Pt 0.11 0.10 KEXP-+Pt KEXP_+Pt 0.23 0.18 KEXP_+Pt 0.17 0.21 KEXP_+Pt KEXP-+Pt 0.16 0.18 KEXP_+Pt KEXP_+Pt 510 Bobbi 0.05 0.19 RI3DCLP+

R13DCLP+

5 10 Bobbi 510 Bobbi 510 Bobbi KEXP_+Pt KEXP_+Pt 0.11 0.15 KEXP +Pt KEXP +Pt 0.11 0.15 KEXP_+Pt 510_Bobbi SpecInt 510 Bobbi R 13DCLP+

0.18 0.14 R13DCLP+

R13DCLP+

0.12 0.14 R13DCLP+

Page 22 of 325

TR-151., Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A Sie.:

Three Mile Island

.411 indications., Jith Length anld J'idth Outage:

1R14 Volt / Origin!

Location Tube#

Cal Probe Degrees Percent Code TSP - Offset Axial Circ Dataset 29 87 81 lOTUL 0

55 0 )Qi TL

-0.97 510 Bobbi

~~~~~.

v

  • v

,I.:

1,

-v 29 87 113 520HF 0.00 0

0 INDF ETL

-0.97 SpecInt 29 94 81 51OUL 2.23 175 0 INR LTE 9.80 510 Bobbi 29 100 73 520HF 0.38 17 ID 25 VOL ETL 0.57 KEXP-+Pt 29 100 73 520HF 0.00 0

0 CLP ETL 0.57 0.21 0.14 KEXP-+Pt 29 100 73 520HF 2.31 43 OD 97 SCI ETL 0.78 KEXP_+Pt 29 100 73 520HF 0.00 57 0 ARC ETL 0.78 0.31 KEXPF+1t 29 100 130 520HF 3.21 50 0

PID ETL 0.99 KEXP+-Pt 29 100 73 520HF 10.89 41 OD 98 SCI ETL 0.99 KEXP_+Pt 29 100 73 520HF 0.00 48 0 ARC ETL 0.99 0.26 KEXP_+Pt 29 100 73 520HF 0.00 0

0 RPD ETL 0.99 KEXP_+Pt 29 101 105 51OUL 3.09 168 0 DNT LTE 10.88 510_Bobbi 30 6

3 51OUL 0.18 94 0 INR LTE 7.58 510 Bobbi 30 23 113 540HF 0.33 10 0

BVC 15S 13.06 540_Bobbi 30 23 115 520HF 0.15 5

0 VOL 15S 13.12 Spec Int 30 23 115 520HF 0.00 0

0 CLP 15S 13.12 0.09 0.11 SpecInt 30 23 113 540HF 0.31 10 0

BVC 15S 34.54 540_Bobbi 30 23 113 540HF 0.31 11 0

BVC 15S 40.19 540_Bobbi 30 23 115 520HF 0.00 0

0 NDF UTS

-11.84 Spec Int 30 23 115 520HF 0.00 0

0 NDF UTS

-6.19 Spec Int 30 36 115 520HF 0.00 0

0 NDF 03S 8.18 SpecInt 30 36 58 51OUL 2.67 178 0 DNT 03S 8.18 510_Bobbi 30 36 58 51OUL 0.14 119 0

INR 14S 31.98 510 Bobbi 30 49 37 51OUL 1.28 86 0

ADI 15S 28.68 510_Bobbi 30 49 160 520HF 0.00 0

0 NDF UTS

-18.12 SpecInt 30 58 37 51OUL 1.45 85 0 ADI 15S 8.12 510 Bobbi 30 58 160 520HF 0.00 0

0 NDF 15S 8.12 SpecInt 30 94 81 51OUL 3.62 173 0 DNT LTE 10.31 510_Bobbi 30 98 105 51OUL 0.14 78 0 NQI 10S

-0.38 510 Bobbi 30 98 156 520HF 0.30 106 OD 10 TWD 10S

-0.29 SpecInt 30 102 12 460PP 0.38 136 0 COD UTE

-1.84 PlugMRP 31 1 117 540HF 0.27 358 0

1NR 04S 12.49 540 Bobbi 31 1 121 520HF 0.51 13 0 VOL 08S 6.62 R13DCLP-+

Page 23 of 325

TR-151, Revision 0 Appendix II Recordable Indications Component:

TM1-OTSG-A Site.

Three Mile island

.1/1 Indications, With Length and TWidth Outage:

1R14 Tube#

Cal Probe 31

1. 12'.

31 1 117 31 40 58 31 40 115 31 66 31 66 31 66 31 66 31 66 79 79 79 68 68 31 75 79 31 95 95 31 103 73 31 103 73 31 103 73 31 103 73 31 103 73 31 103 73 31 103 106 32 4 42 32 4

42 32 50 56 32 50 56 32 60 56 32 60 56 32 81 110 32 81 110 32 81 123 32 81 123 32 81 123 32 81 123 32 81 123 32 81 123 32 82 67 32 82 67 540HF 51OUL 520HF 520HF 520HF 520HF 520HF 520HF 520HF 51OUL 520HF 520HF 520HF 520HF 520HF 520HF 51OUL 520HF 520HF 520HF 520HF 520HF 520HF 540HF 540HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF IVolt / Origin/

Degrees Percent 0.00 0

0.36 15 0.42 84 0.52 0

0.34 0.00 0.08 0.66 0.00 ID 28 0

24 40 0

0.18 63 3.31 180 0.00 0.71 3.32 0.00 1.56 0.00 3.12 0

20 41 78 23 0

172 0.49 24 0.00 0

0.44 20 0.00 0

0.27 11 0.00 0

0.81 0.60 0.95 0.00 0.00 0.35 0.41 0.00 9

6 22 0

0 16 19 0

0.38 18 0.00 0

Location Code TSP - Offset 0

CLP 08S 0

BVC 08S 0

NQI 08S 6

TWD 08S 0

0 0

0 0

VOL ETL CLP ETL PRA ETL VOL ETL CLP ETL 0

INR ETL 6.62 6.69 0.65 0.69

-3.47

-3.47

-0.21

-0.08

-0.08

-1.28 0

DNT LTE 10.24 0

ID 33 OD 98 0

ID 43 0

0 CLP ETL VOL ETL SCI ETL ARC ETL VOL ETL CLP ETL DNT LTE ID 47 VOL ETL 0

CLP ETL 0 VOL ETL 0 CLP ETL 0 VOL ETL 0

CLP ETL ID ID ID 30 20 0

0 0

0 0

0 TWD 15S TWD 15S VOL UTS CLP UTS CLP UTS VOL UTS VOL UTS CLP UTS 27 VOL ETL 0

CLP ETL 1.78 1.78 2.74 2.74 3.84 3.84 11.80 1.08 1.08

-0.11

-0.11

-1.43

-1.43 35.42 35.77

-11.30

-11.30

-10.48

-10.48

-3.42 42 2.34 2.34 Axial Circ Dataset 0.14 0.11 R13DCLP+

540_Bobbi 510 Bobbi SpecInt R13DCLP+

0.12 0.14 R13DCLP+

R13DCLP+

KEXP_+Pt 0.17 0.19 KEXP_+Pt R13DCLP+

510 Bobbi 0.21 0.14 KEXP_+Pt KEXP_+Pt KEXP_+Pt 0.42 KEXP_+Pt KEXP_+Pt 0.16 0.19 KEXP_+Pt 510 Bobbi KEXP_+Pt 0.12 0.14 KEXP_+Pt KEXP_+Pt 0.11 0.10 KEXP -+Pt KEXP_+Pt 0.11 0.19 KEXP_+Pt 540_Bobbi 540 Bobbi R13DCLP+

0.15 0.16 R13DCLP+

0.15 0.16 R13DCLP+

R 13DCLP+

R13DCLP+

0.19 0.16 RI3DCLP+

KEXP +Pt 0.16 0.18 KEXP +Pt Page 24 of 325

TR-151, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A Site:

Three Mile Island All Indications, With Length and ITlidth Outage:

11R14 Tube#

Cal Probe 32 94 32 94 32 94 32 94 32 95 32 95 32 95 32 95 32 96 32 96 32 96 32 96 68 68 68 68 67 67 67 67 73 73 73 73 32 97 18 32 97 18 32 104 73 32 104 73 32 104 105 33 7

4 9

9 9

9 42 42 42 42 33 20 59 33 52 38 67 67 67 67 67 67 67 67 68 68 68 68 68 68 68 68 33 70 79 33 70 79 1520HIF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 51OUL 51 OUL 520HF 520HF 520HF 520HF 51OUL 51OUL 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF J'olt / Origin/

Degrees Percent U.,/L 0.00 0.40 0.00 Zv 0

20 0

0.25 18 0.00 0

0.33 22 0.00 0

0.31 16 0.00 0

0.00 0

0.29 23 8.39 47 0.00 45 0.97 10 0.00 0

3.91 171 0.49 101 0.44 0.00 0.00 0.56 21 0

0 23 0.17 122 0.26 130 0.47 0.00 0.00 0.19 0.00 0.23 0.85 0.00 18 0

0 9

0 24 25 0

0.00 0

0.34 31 Location Code TSP - Offset 0 VOL ETL 0 CLP ETL 0 VOL ETL 0 CLP ETL 0 VOL ETL 0

CLP ETL ID 40 VOL ETL 0 CLP ETL ID 22 VOL ETL 0

CLP ETL 0

CLP ETL ID 43 VOL ETL OD 96 SCI ETL 0 ARC ETL ID 9 VOL ETL 0

CLP ETL 0

DNT LTE 0

INR LTE 0 VOL ETL 0

CLP ETL 0

CLP ETL ID 43 VOL ETL 0

INR 13S 0

INR 14S ID 27 VOL ETL 0

CLP ETL 0

CLP ETL ID 8

VOL ETL 0

CLP ETL ID 47 VOL ETL ID 51 VOL ETL 0

CLP ETL 0

CLP ETL 0

VOL ETL

-0.09

-0.09

-0.08

-0.08

-1.37

-1.37 3.85 3.85 0.07 0.07 1.97 1.97 4.96 4.96 1.49 1.49 10.97 11.86

-0.17

-0.17 0.88 0.88

-0.03 33.40 0.03 0.03 2.14 2.14 2.93 2.93 3.34 3.34

-2.34

-2.34 Axial Circ Dataset KEXP +Pt 0.17 0.18 KEXP +Pt KEXP +Pt 0,11 0.14 KEXP_+Pt KEXP_+Pt 0.11 0.14 KEXP_+Pt KEXP_+Pt 0.16 0.14 KEXP_+Pt KEXP_+Pt 0.21 0.19 KEXP_+Pt 0.16 0.12 KEXP_+Pt KEXP_+Pt KEXP_+Pt 0.24 KEXP_+Pt KEXP_+Pt 0.27 0.23 KEXP_+Pt 510_Bobbi 510 Bobbi KEXP_+Pt 0.11 0.15 KEXP_+Pt 0.11 0.15 KEXP_+Pt KEXP_+Pt 510 Bobbi 510 Bobbi KEXP_+Pt 0.19 0.18 KEXP_+Pt 0.17 0.14 KEXP_+Pt KEXP_+Pt 0.11 0.14 KEXP_+Pt KEXP +Pt KEXP +Pt 0.17 0.19 KEXP_+Pt 0.12 0.14 R13DCLP+

R13DCLP+

Page 25 of 325 33 33 33 33 33 33 33 33 33 33 33 33

TR-151, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A Site:

Three Mile Island All Indications, J4 Tith Length and Width Outage:

1R14 33 90 33 90 33 90 33 90 33 90 33 92 33 92 33 92 33 92 33 92 33 92 33 92 33 92 33 92 Tube#

Cal Probe 68 68 68 68 68 68 68 68 68 68 68 68 68 68 33 97 108 33 97 108 33 97 108 33 97 156 33 97 156 33 97 156 33 97 156 33 97 156 33 97 156 33 97 156 33 97 156 33 97 156 33 97 156 33 99 73 33 99 73 3-2 02 M) 33 83 123 33 83 123 33 83 123 33 83 123 33 83 110 33 83 123 33 83 123 33 83 123 33 83 123 Volt / Origin/

Degrees Percent 540HF 520HF 520HF 520HF 520HF 540HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 540HF 540HF 540HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 0.37 0.00 0.26 0.16 0.00 0.60 0.46 0.00 0.00 0.12 0.40 0.00 0.00 0.67 0.35 0.21 0.00 0.29 0.24 0.00 0.74 0.00 0.32 0.00 0.31 0.22 0.35 0.11 0.00 0.10 0.00 0.43 0.00 0.25 0.00 0.00 0.17 1.42 30 0.00 0

0 0

0 0

0 ID 43 0

0 0

0 ID 0

0 0

33 0

Location Code TSP - Offset BVC iSS CLP UTS VOL UTS VOL UTS CLP UTS TWD UTS VOL UTS CLP UTS CLP UTS VOL UTS VOL ETL CLP ETL CLP ETL VOL ETL INR ETL 10 0

19 17 0

13 14 0

0 30 34 0

0 20 14 1

90 33 25 0

20 0

31 0

3 10 16 3

0 16 0

20 0

17 0

0 10 45.10

-11.98

-11.98

-1.33

-1.33 1.89 1.96 1.96 3.64 3.64

-1.76

-1.76 1.53 1.53 2.72

-1.16 0.54 0.54 1.30 1.30 3.26 3.26 3.97 3.97 10.28 26.47 36.63

-21.65

-21.65

-20.70

-20.70

-10.61

-10.61

-7.01

-7.01

-6.44

-6.44 2.19 2.19 Axial Circ Dataset 540 Bobbi 0.15 0.16 R13DCLP+

R13DCLP+

R13DCLP+

0.15 0.16 R13DCLP+

540_Bobbi R13DCLP+

0.15 0.16 R13DCLP+

0.15 0.16 R13DCLP+

R13DCLP+

KEXP_+Pt 0.17 0.14 KEXP-+Pt 0.11 0.14 KEXP_+Pt KEXP_+Pt KEXP_+Pt KEXP_+Pt 0.11 0.14 KEXP_+Pt KEXP_+Pt KEXP_+Pt 0.11 0.14 KEXP-+Pt KEXP_+Pt 0.11 0.14 KEXP_+Pt KEXP_+Pt 0.11 0.14 KEXP-+Pt 540_Bobbi 540_Bobbi 540_Bobbi Spec lnt 0.15 0.12 Spec lnt SpecInt 0.10 0.12 SpecInt SpecInt 0.10 0.12 SpecInt SpecInt 0.10 0.12 Specmnt 0.15 0.12 Spec Int Specmln KEXP-+Pt 0.16 0.09 KEXP -+Pt Page 26 of 325 0

INR ETL 0

CLP ETL ID 86 VOL ETL ID 51 VOL ETL 0

CLP ETL ID 33 VOL ETL 0

CLP ETL ID 76 VOL ETL 0 CLP ETL 0

INR 15S 0

BVC 15S 0

BVC 15S 0

VOL UTS 0

CLP UTS 0

VOL UTS 0

CLP UTS 0

VOL UTS 0

CLP UTS 0 VOL UTS 0

CLP UTS 0

CLP UTS 0

VOL UTS ID 71 VOL ETL 0

CLP ETL

TR-151, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A Site:

Three Mille island

.41 Indications. IT'ith Leigth and JI'idth Outage:

1R14 Tube#

Cal Probe V4olt / Origin!

Degrees Percent Location Code TSP - Offset 0

INR 15S 0

NQI 15S 0

NDF 15S 0

0 0

0 0

0 ID 27 0

0 0

0 0

VOL ETL CLP ETL VOL ETL CLP ETL CLP UTS VOL UTS TWD UTS BVC UTS VOL UTS CLP UTS CLP UTS VOL UTS 33 102 108 33 104 106 33 104 156 540HF 51OUL 520HF 520HF 520HF 520HF 520HF 520HF 520HF 540HF 540HF 520HF 520HF 520HF 520HF 51OUL 51OUL 51OUL 520HF 51OUL 51 OUL 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF TWD 06S NQI 06S INR 11S ID 40 VOL ETL 0

CLP ETL ID 47 VOL ETL 0

CLP ETL ID 36 0

ID 67 0

ID 54 0

ID 43 0

VOL ETL CLP ETL VOL ETL CLP ETL VOL ETL CLP ETL VOL ETL CLP ETL 0.50 4

0.31 118 0.00 0

540_Bobbi 510_Bobbi SpecInt R13DCLP+

0.10 0.11 R13DCLP+

R13DCLP+

0.10 0.11 R13DCLP+

0.14 0.16 R13DCLP+

RI3DCLP+

540_Bobbi 540_Bobbi R13DCLP+

0.10 0.11 R13DCLP+

0.14 0.16 R13DCLP+

R13DCLP+

510 Bobbi 5.89 4.80 4.80

-2.52

-2.52

-2.41

-2.41 1.82 1.82 1.89 3.76 3.82 3.82 4.90 4.90 10.92 10.92

-0.38 0.63 0.63 30.95 2.16 2.16 2.93 2.93 0.50 0.50 2.03 2.03 0.54 0.54 0.92 0.92 KEXP_+Pt 0.12 0.14 KEXP_+Pt KEXP_+Pt 0.17 0.25 KEXP_+Pt KEXP-+Pt 0.11 0.15 KEXP_+Pt KEXP-+Pt 0.12 0.14 KEXP_+Pt KEXP_+Pt 0.34 0.18 KEXP +Pt KEXP-+Pt 0.17 0.18 KEXP -+Pt Page 27 of 325 ID 11 0

0 510 Bobbi 510_Bobbi SpecInt 510_Bobbi 510_Bobbi Axial Circ Dataset 34 34 34 34 34 34 34 34 34 34 34 34 3 121 3 121 3 121 3 121 3 121 3 121 3 117 3 117 3 121 3 121 3 121 3 121 0.46 0.00 0.54 0.00 0.00 1.03 0.46 0.35 0.26 0.00 0.00 0.42 21 0

24 0

0 29 8

10 18 0

0 21 0

DNT LTE 0

DNT LTE 0

INR 12S 34 5

3 34 6

4 34 21 58 34 25 115 34 25 58 34 25 58 34 38 51 34 38 51 34 53 55 34 53 55 34 62 56 34 62 56 34 64 56 34 64 56 34 76 68 34 76 68 34 76 68 34 76 68 5.86 176 6.04 174 0.16 39 0.96 0

0.45 43 0.18 155 0.56 22 0.00 0

1.12 24 0.00 0

0.55 21 0.00 0

0.93 29 0.00 0

0.24 26 0.00 0

0.19 23 0.00 0

TR-151, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A Site:

Three Mile Island All ndiccations, `Wit Length and Width Outage:

1R14 T'olt / Origini Degrees Percent Location Code TSP - Offset Tube#

34 103 73 34 103 73 35 5

3 35 7

4 35 26 58 35 27 79 35 27 79 35 27 79 35 27 79 35 27 79 35 27 79 35 27 79 35 27 79 35 27 79 35 27 79 35 32 58 35 42 115 35 42 59 35 48 38 35 55 38 35 55 133 35 104 105 35 104 105 36 7

3 36 8

4 36 27 58 36 88 96 36 96 110 36 96 123 36 96 123 36 103 156 Cal Axial Circ Dataset Probe

'2OHF 520HF 51OUL 51OUL 51OUL 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 51OUL 520HF 51OUL 51OUL 51 OUL 520HF 51 OUL 51OUL 51OUL 51 OUL 51OUL 51OUL 540HF 520HF 520HF 520HF Page 28 of 325 1.21 23 iD 43 VOL ELL 0.00 0

0 CLP ETL 5.78 176 0

DNT LTE 6.60 176 0

DNT LTE 0.19 19 0 INR 14S 0.61 30 0

VOL ETL 0.00 0

0 CLP ETL 0.71 28 ID 63 VOL ETL 0.00 0

0 CLP ETL 0.55 29 ID 67 VOL ETL 0.00 0

0 CLP ETL 0.38 20 ID 33 VOL ETL 0.00 0

0 CLP ETL 0.36 21 ID 36 VOL ETL 0.00 0

0 CLP ETL 0.16 114 0

INR 02S 0.00 0

0 NDF 01S 1.34 23 0

ADI 01S 1.31 88 0

INR 01S 3.29 181 0

DNT 02S 0.00 0

0 NDF 03S 0.52 112 0

INR 11S 2.46 172 0

INR LTE 5.47 177 0 DNT LTE 6.38 174 0

DNT LTE 3.19 182 0

DNT LTS 0.64 110 0

INR LTE 0.43 6

ID 20 TWD 15S 0.09 38 0

VOL UTS 0.00 0

0 CLP UTS 0.00 0

0 NDF 01S 0.52 0.52 10.79 10.70 21.63

-1.38

-1.38 1.37 1.37 3.36 3.36 4.91 4.91 5.00 5.00 19.22 14.65 14.65 30.20 11.52

-27.48 0.16 10.81 11.11 10.75 40.90 4.87 29.79

-16.57

-16.57

-11.02 KEXP +Pt 0.21 0.19 KEXP_+Pt 510_Bobbi 510 Bobbi 510_Bobbi R13DCLP+

0.12 0.18 R13DCLP+

R13DCLP+

0.12 0.18 R13DCLP+

R13DCLP+

0.12 0.09 R13DCLP+

R 1 3DCLP+

0.12 0.09 R13DCLP+

R13DCLP+

0.18 0.18 R13DCLP+

510_Bobbi Speclnt 510_Bobbi 510_Bobbi 510 Bobbi SpecInt 510_Bobbi 510_Bobbi 510_Bobbi 510_Bobbi 510 Bobbi 510 Bobbi 540_Bobbi R13DCLP+

0.14 0.17 R13DCLP+

Spec tnt

TR-151, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A Site:

Three Mile island All Indications, 1'ith Length and Wicdth Outqagze:

1R14 Volt / Origir/

Location Tube#

Cal Probe Degrees Percent Code TSP - Offset Axial Circ Dataset 36 10. 106 j lVUL 0.44 63 0 NQi LTS 34.98 510_Bobbi 36 106 108 540HF 0.55 8

ID 27 TWD 15S 34.41 540 Bobbi 36 106 156 520HF 0.28 8

0 VOL UTS

-12.19 Spec Int 36 106 156 520HF 0.00 0

0 CLP UTS

-12.19 0.15 0.11 Spec Int 36 106 156 520HF 0.00 0

0 CLP UTS

-2.16 0.15 0.17 SpecInt 36 106 156 520HF 0.37 21 0

VOL UTS

-2.16 Spec Int 36 109 105 51OUL 2.84 176 0

DNT LTE 10.47 510 Bobbi 36 110 156 520HF 0.65 79 OD 20 TWD 12S 0.66 Spec Int 36 110 105 51OUL 0.87 99 0

NQI 12S 0.66 510_Bobbi 36111 106 51OUL 3.64 175 0 DNT LTE 11.82 510_Bobbi 37 1

4 51OUL 8.28 176 0 DNT LTE 10.68 510_Bobbi 37 12 3

51OUL 0.19 103 0

NQI 08S

-0.49 510_Bobbi 37 12 110 520HF 0.65 106 OD 7

TWD 08S

-0.47 SpecInt 37 27 113 540HF 0.34 4

0 INR 07S 30.63 540_Bobbi 37 27 113 540HF 0.34 9

0 BVC 13S 20.97 540_Bobbi 37 27 115 520HF 0.00 0

0 NDF 14S

-15.03 SpecInt 37 27 115 520HF 0.29 18 0

VOL 14S

-6.39 SpecInt 37 27 115 520HF 0.00 0

0 CLP 14S

-6.39 0.09 0.11 SpecInt 37 28 50 520HF 0.29 12 0

VOL ETL

-2.00 KEXP-+Pt 37 28 50 520HF 0.00 0

0 CLP ETL

-2.00 0.11 0.15 KEXP_+Pt 37 31 50 520HF 0.00 0

0 CLP ETL 0.02 0.17 0.10 KEXP-+Pt 37 31 50 520HF 0.37 19 ID 30 VOL ETL 0.02 KEXP_+Pt 37 31 50 520HF 0.23 12 ID 13 VOL ETL 0.74 KEXP_+Pt 37 31 50 520HF 0.00 0

0 CLP ETL 0.74 0.11 0.10 KEXP_+Pt 37 40 58 510UL 0.83 83 0

INR 02S 20.99 510 Bobbi 37 40 58 510UL 0.56 77 0

INR 06S 12.86 510 Bobbi 37 40 58 510UL 3.06 81 0

ADI 06S 22.94 510 Bobbi 37 40 115 520HF 0.00 0

0 NDF 07S

-16.06 Spec Int 37 40 51 520HF 0.00 0

0 CLP ETL 0.75 0.12 0.19 KEXP_+Pt 37 40 51 520HF 0.42 16 ID 22 VOL ETL 0.75 KEXP +Pt 37 40 51 520HF 0.24 16 ID 22 VOL ETL 2.59 KEXP-+Pt 37 40 51 520HF 0.00 0

0 CLP ETL 2.59 0.12 0.14 KEXP -+Pt 37 45 50 520HF 0.24 14 0

VOL ETL

-0.74 KEXP_+Pt 37 45 50 520HF 0.00 0

0 CLP ETL

-0.74 0.11 0.15 KEXP +Pt Page 29 of 325

TR-151, Revision 0 Appendix 1I Recordable Indications CoMponent:

TMI-OTSG-A S.I,,:

Three Mile,sland

.41 Indications, With Length and Wi'idth Out age:

1R14 Volt / Origin/

Location Tube#

Cal Probe Degrees Percent Code TSP - Offset Axial Circ Dataset 37 56 56 520HF 1.31 31 0 VOL ETL

-0.71 KEXP_+Pt 37 56 56 520HF 0.00 90 0

CLP ETL

-0.71 0.06 0.20 KEXP_+Pt 37 56 56 520HF 0.70 19 ID 30 VOL ETL 2.78 KEXP +Pt 37 56 56 520HF 0.00 90 0

CLP ETL 2.78 0.06 0.10 KEXP_+Pt 37 67 55 520HF 0.00 0

0 CLP ETL 0.05 0.17 0.15 KEXP-+Pt 37 67 55 520HF 0.44 28 ID 63 VOL ETL 0.05 KEXP_+Pt 37 100 105 51OUL 0.15 79 0 INR LTE 12.65 510_Bobbi 37 107 106 51OUL 0.28 110 OD 5 TWD 11S

-0.59 510_Bobbi 37 109 159 540HF 0.15 89 0 NQI 10S 25.90 540_Bobbi 37 109 135 520HF 0.00 0

0 NDF 11S

-10.10 SpecInt 37 109 159 540HF 0.29 3

0 INR 15S 35.10 540_Bobbi 37 109 159 540HF 0.48 7

0 INR 15S 39.11 540_Bobbi 37 109 73 520HF 0.00 0

0 CLP ETL

-0.63 0.16 0.19 KEXP_+Pt 37 109 73 520HF 0.52 17 0

VOL ETL

-0.63 KEXP_+Pt 37 109 73 520HF 0.52 14 0

VOL ETL

-0.09 KEXP_-+Pt 37 109 73 520HF 0.00 0

0 CLP ETL

-0.09 0.16 0.23 KEXP-+Pt 37 109 73 520HF 0.89 20 ID 33 VOL ETL 0.01 KEXP_+Pt 37 109 73 520HF 0.00 0

0 CLP ETL 0.01 0.11 0.19 KEXP-+Pt 37 109 159 540HF 4.17 173 0

DNT LTE 10.80 540_Bobbi 37 109 167 520HF 0.00 0

0 CLP UTS

-11.64 0.14 0.16 R13DCLP+

37 109 167 520HF 0.24 11 0

VOL UTS

-11.64 R13DCLP+

37 109 167 520HF 0.30 17 0

VOL UTS

-9.00 R13DCLP+

37 109 167 520HF 0.00 0

0 CLP UTS

-9.00 0.14 0.16 R13DCLP+

37 109 167 520HF 0.00 0

0 CLP UTS

-7.45 0.14 0.22 R13DCLP+

37 109 167 520HF 0.76 22 0

VOL UTS

-7.45 R13DCLP+

37 109 167 520HF 0.24 13 0

VOL UTS

-0.37 KEXP_-+Pt 37 109 167 520HF 0.00 0

0 CLP UTS

-0.37 0.18 0.16 KEXP_+Pt 37 110 156 520HF 0.00 0

0 NDF 15S

-0.13 Spec nt 37 110 108 540HF 0.22 101 0 NQI 15S

-0.13 540_Bobbi 37 110 108 540HF 0.42 3

0 INR 15S 32.67 540_Bobbi 37 110 108 540HF 0.24 7

0 BVC 15S 35.26 540_Bobbi 37 110 108 540HF 4.38 174 0

DNT LTE 11.17 540_Bobbi 37 110 156 520HF 0.24 10 0

VOL UTS

-14.77 RI3DCLP+

37 110 156 520HF 0.00 0

0 CLP UTS

-14.77 0.15 0.17 R13DCLP+

37 110 156 520HF 0.17 19 0

VOL UTS

-11.88 SpecInt 37 110 156 520HF 0.00 0

0 CLP UTS

-11.88 0.20 0.11 Spec Int 37 110 156 520HF 0.00 0

0 CLP UTS

-5.07 0.10 0.17 Spec Int 37 110 156 520HF 0.19 22 0

VOL UTS

-5.07 Speclnt Page 30 of 325

TR-151, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A Site.

Th-ree, M1ile Island

.Ill Indications, IHith Length and 14 idth Outage:

1R14 Volt / Originl Degrees Percent 0.00 0

Tube#

37 110-156 37 110 156 37 110 156 37 110 156 37 110 108 37 110 156 37 110 156 38 6

3 38 10 3

38 34 59 38 81 67 38 81 67 38 88 67 38 88 67 38 88 67 38 88 67 38 105 156 38 105 105 38 114 12 39 4

3 39 4 110 39 14 3

39 24 59 39 29 50 39 29 50 39 40 50 39 40 50 39 46 115 39 46 59 39 50 37 39 57 56 Cal Location Code TSP - Offset 0

CLP UTS

-0.88 Probe 520HF 520HF 520HF 520HF 540HF 520HF 520HF 51OUL 51OUL 51OUL 520HF 520HF 520HF 520HF 520HF 520HF 520HF 51OUL 460PP 51OUL 520HF 51OUL 51OUL 520HF 520HF 520HF 520HF 520HF 51OUL 51OUL 520HF 0.10 0.15 0.00 0.24 0.00 0.31 0.21 2.60 0.14 0.00 1.16 0.36 0.00 0.28 0.00 0.64 0.22 1.47 0.25 0.00 0.15 0.56 0.00 0.37 0.50 0.00 0.00 1.13 2.58 0.78 19 22 0

16 0

17 92 186 62 0

20 23 0

13 0

76 83 138 87 0

78 108 0

19 13 0

0 81 181 24 Page 31 of 325 0

VOL UTS 0

VOL UTS 0

CLP UTS 0

BVC UTS 0

CLP UTS 0

VOL UTS OD 4

TWD 09S 0

DNT LTS OD 4 TWD 10S 0

CLP ETL ID 33 VOL ETL 0 VOL ETL 0

CLP ETL ID 15 VOL ETL 0

CLP ETL OD 10 TWD 09S 0 NQI 09S 0

COD UTE 0

NQI 10S 0

NDF 10S 0

INR UTS 0

INR LTE 0

CLP ETL 0

VOL ETL ID 15 VOL ETL 0

CLP ETL 0

NDF OSS 0

ADI 08S 0

DNT 13S ID 47 VOL ETL

-0.88

-0.38

-0.38 2.42 2.64 2.64 0.49 9.56 0.68 0.10 0.10

-0.96

-0.96 0.42 0.42 0.14 0.17

-1.75

-0.75

-0.75 0.66 6.16

-0.40

-0.40 0.01 0.01 5.76 5.76 21.09 1.85 Axial Circ Dataset 0.08 0.10 Spec Int SpecInt SpecInt 0.10 0.12 SpecInt 540_Bobbi 0.15 0.17 Spec.Int SpecInt 510_Bobbi 510_Bobbi 510 Bobbi 0.16 0.14 KEXP_+Pt KEXP_+Pt KEXP_+Pt 0.16 0.14 KEXP_+Pt KEXP_+Pt 0.16 0.19 KEXP_+Pt Spec Int 510 Bobbi PlugMRP 510_Bobbi SpecInt 510 Bobbi 510_Bobbi 0.11 0.15 KEXP_+Pt KEXP_+Pt KEXP_+Pt 0.11 0.12 KEXP_+Pt Spec Int 510 Bobbi 510 Bobbi KEXP +Pt

TR-151, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A

Site, Three Mile Island All Indications., 117ih Length and i'Vidlth Outage:

1R14 Volt / Origin/

Location Tube#

Cal Probe Degrees Percent Code TSP - Offset Axial Cire Dataset 39 57 5..6..

F 0.00 0

0 CLP ETL 1.85 0.11 0.15 KEXP_+Pt 39 68 55 520HF 0.00 0

0 CLP ETL 2.61 0.17 0.20 KEXP +Pt 39 68 55 520HF 0.62 17 ID 25 VOL ETL 2.61 KEXP +Pt 39 68 55 520HF 0.75 24 ID 47 VOL ETL 4.78 KEXP +Pt 39 68 55 520HF 0.00 0

0 CLP ETL 4.78 0.22 0.25 KEXP_+Pt 39 73 67 520HF 0.24 32 ID 81 VOL ETL 2.49 KEXP_+Pt 39 73 67 520HF 0.00 0

0 CLP ETL 2.49 0.16 0.18 KEXP-+Pt 39 73 67 520HF 0.34 19 ID 30 VOL ETL 3.56 KEXP-+Pt 39 73 67 520HF 0.00 0

0 CLP ETL 3.56 0.16 0.14 KEXP_+Pt 39 73 67 520HF 0.64 15 ID 20 VOL ETL 4.53 KEXP_+Pt 39 73 67 520HF 0.00 0

0 CLP ETL 4.53 0.16 0.18 KEXP_+Pt 39 73 67 520HF 0.25 13 ID 15 VOL ETL 5.15 KEXP_+Pt 39 73 67 520HF 0.00 0

0 CLP ETL 5.15 0.14 0.14 KEXP_+Pt 39 89 67 520HF 0.28 22 ID 40 VOL ETL 0.00 KEXP_+Pt 39 89 67 520HF 0.00 0

0 CLP ETL 0.00 0.11 0.12 KEXP-+Pt 39 89 67 520HF 0.31 22 ID 40 VOL ETL 2.50 KEXP_+Pt 39 89 67 520HF 0.00 0

0 CLP ETL 2.50 0.12 0.19 KEXP_+Pt 39 101 108 540HF 0.47 7

ID 23 TWD 15S 34.58 540 Bobbi 39 101 156 520HF 0.00 0

0 CLP UTS

-13.71 0.15 0.11 Spec _nt 39 101 156 520HF 0.19 20 0 VOL UTS

-13.71 Spec Int 39 101 156 520HF 0.28 12 0 VOL UTS

-12.50 Spec Int 39 101 156 520HF 0.00 0

0 CLP UTS

-12.50 0.15 0.11 SpecInt 39 107 156 520HF 0.00 0

0 NDF 10S

-0.17 Spec Int 39 107 106 51OUL 0.08 67 0

NQI 10S

-0.17 510_Bobbi 39 110 108 540HF 0.45 9

ID 30 TWD 15S 39.68 540 Bobbi 39 110 108 540HF 0.23 5

0 BVC 15S 41.74 540 Bobbi 39 110 73 520HF 0.88 26 ID 54 VOL ETL 1.28 KEXP_+Pt 39 110 73 520HF 0.00 0

0 CLP ETL 1.28 0.11 0.19 KEXP +Pt 39 110 73 520HF 0.00 0

0 CLP ETL 4.22 0.16 0.14 KEXP +Pt 39 110 73 520HF 0.40 5

ID 3 VOL ETL 4.22 KEXP +Pt 39 110 108 540HF 3.51 175 0

DNT LTE 10.87 540 Bobbi 39 110 156 520HF 0.00 0

0 CLP UTS

-7.33 0.20 0.17 Spec Int 39 110 156 520HF 0.74 26 0

VOL UTS

-7.33 Spec Int 39 110 156 520HF 0.16 19 0 VOL UTS

-5.19 Spec Int 39 110 156 520HF 0.00 0

0 CLP UTS

-5.19 0.15 0.11 Spec Int 39 110 156 520HF 0.23 38 0 VOL UTS

-4.57 Spec Int 39 110 156 520HF 0.00 0

0 CLP UTS

-4.57 0.10 0.11 Spec mnt Page 32 of 325

TR-151, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A Site:

Three Mile Island All Indications, 11 ith Len-gh and 1`0'id1h Ozftge:

1R14 Volt / Origin/

Degrees Percent 0.00 0

0.19 15 0.18 16 0.00 0

0.00 0

0.39 12 0.26 20 0.00 0

Tube#

39 11 156 39 110 156 39 110 156 39 110 156 39 110 156 39 110 156 39 110 156 39 110 156 39 113 105 39 113 105 39 113 105 39 114 106 40 15 3

40 31 52 40 31 115 40 44 115 40 44 53 40 49 50 40 49 50 40 50 41 40 50 133 40 74 90 40 74 113 40 106 105 41 14 33 41 14 33 41 15 3

41 15 3

41 16 110 41 16 117 41 17 33 41 17 33 0

0 0

0 0

0 0

0 0

0 0

Code

.,P VOL VOL CLP CLP VOL VOL CLP INR INR DNT Location TSP - Offset UTS

-3.56 UTS

-3.56 UTS

-0.75 UTS

-0.75 UTS 0.00 UTS 0.00 UTS 1.36 UTS 1.36 14S 30.87 15S 0.97 LTE 10.70 Cal Probe 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 520HF 520HF 51OUL 520HF 520HF 51OUL 520HF 51OUL 520HF 51OUL 520HF 520HF 51OUL 51OUL 520HF 540HF 520HF 520HF 0.15 60 0.25 89 5.43 175 4.82 174 0.28 94 0.57 86 0.00 0

0.00 0

0.18 90 0.98 23 0.00 0

2.96 185 0.00 0

0.75 85 0.00 0

0.46 99 0.00 0

0.61 22 0.22 104 0.13 87 0.00 0

0.17 92 0.13 67 0.23 359 Axial Circ Dataset 0.15 0.1i Spec int Specmnt R13DCLP+

0.15 0.11 RI3DCLP+

0.15 0.17 RI3DCLP+

RI3DCLP+

R13DCLP+

0.10 0.17 R13DCLP+

510 Bobbi 510_Bobbi 510 Bobbi 51t0Bobbi 510 Bobbi 510 Bobbi SpecInt SpecInt 510 Bobbi KEXP_+Pt 0.11 0.15 KEXP-+Pt 510 Bobbi Spec Int 510_Bobbi SpecInt 510 Bobbi 0.15 0.24 KEXP-+Pt KEXP-+Pt 510 Bobbi 510 Bobbi Spec lnt 540_Bobbi KEXP +Pt KEXP -+Pt Page 33 of 325 11.12 10.07 5.58

-18.42

-22.48 23.89

-0.49

-0.49 16.84

-23.16 29.00

-10.00 20.22

-0.31

-0.31 10.68 14.95 2.87 2.87

-2.06

-0.20 0 DNT LTE 0

INR LTE 0 NQI LTE 0 NDF LTS 0 NDF 01S 0 NQI LTS 0

VOL ETL 0

CLP ETL 0

DNT 03S 0 NDF 04S 0

ADI 08S 0 NDF 09S 0

TNR LTE 0

CLP ETL 0

VOL ETL 0

INR LTE 0

INR LTE 0

NDF 14S 0

NQ]

14S 0

INR ETL 0

INR ETL

TR-151, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A Site:

Three Mile Island

.411 hnliCationlS. With Length and Width Ouaqge:

1R14 Volt,/ Origin/

Location Tube#

Cal Probe Degrees Percent Code TSP - Offset Axial Circ Dataset 41 18 3

,IOMUL 0.18

130, 0

-N, L TE U6.27 510 Bobbi 41 23 33 520HF 0.49 31 0

VOL ETL

-0.27 KEXP_+Pt 41 23 33 520HF 0.00 0

0 CLP ETL

-0.27 0.10 0.15 KEXP_+Pt 41 23 33 520HF 0.46 27 ID 55 VOL ETL 0.20 KEXP-+Pt 41 23 33 520HF 0.00 0

0 CLP ETL 0.20 0.10 0.15 KEXP_+Pt 41 24 50 520HF 0.15 10 0 VOL ETL

-2.85 KEXP_+Pt 41 24 50 520HF 0.00 0

0 CLP ETL

-2.85 0.17 0.10 KEXP_+Pt 41 24 50 520HF 0.27 20 ID 33 VOL ETL 0.49 KEXP_+Pt 41 24 50 520HF 0.00 0

0 CLP ETL 0.49 0.17 0.15 KEXP_+Pt 41 24 50 520HF 0.48 18 ID 27 VOL ETL 2.70 KEXP_+Pt 41 24 50 520HF 0.00 0

0 CLP ETL 2.70 0.17 0.15 KEXP_+Pt 41 24 50 520HF 0.00 0

0 CLP ETL 3.75 0.11 0.15 KEXP_+Pt 41 24 50 520HF 0.19 20 ID 33 VOL ETL 3.75 KEXP_+Pt 41 50 42 51OUL 2.89 184 0

DNT 01S 23.40 510 Bobbi 41 60 55 520HF 0.19 7

0 VOL ETn

-0.84 KEXP_+Pt 41 60 55 520HF 0.00 0

0 CLP ETL

-0.84 0.17 0.15 KEXP_+Pt 41 60 55 520HF 0.54 24 ID 47 VOL ETL 0.72 KEXP_+Pt 41 60 55 520HF 0.00 0

0 CLP ETL 0.72 0.22 0.20 KEXP_+Pt 41 60 55 520HF 0.00 0

0 CLP ETL 4.16 0.17 0.15 KEXP_+Pt 41 60 55 520HF 0.42 24 ID 47 VOL ETL 4.16 KEXP_+Pt 41 67 41 51OUL 2.42 188 0

INR 03S 17.40 510_Bobbi 41 67 41 51OUL 2.57 187 0

DNT 06S 2.90 510_Bobbi 41 67 41 51OUL 3.68 185 0

DNT LTE 9.60 510 Bobbi 41 81 79 520HF 0.16 12 0

VOL ETL

-2.41 R13DCLP+

41 81 79 520HF 0.00 0

0 CLP ETL

-2.41 0.12 0.14 RI3DCLP+

41 94 110 540HF 0.49 5

ID 17 TWD 15S 15.98 540_Bobbi 41 94 123 520HF 0.30 9

0 VOL 15S 16.11 R13DCLP+

41 94 123 520HF 0.00 0

0 CLP 15S 16.11 0.14 0.17 R13DCLP+

41 105 156 520HF 0.00 0

0 NDF 01S

-34.88 10.89 Spec Int 41 105 105 51OUL 6.62 182 0

IDC LTS 11.12 56.89 510 Bobbi 41 106 106 51OUL 0.22 78 0

NQI 08S

-0.82 510_Bobbi 41 106 156 520HF 0.40 63 OD 13 TWD 08S

-0.82 SpecInt 41 109 79 520HF 0.00 0

0 CLP ETL

-3.39 0.12 0.09 RI3DCLP+

41 109 79 520HF 0.18 35 0

VOL ETL

-3.39 R13DCLP+

41 109 79 520HF 0.42 26 ID 54 VOL ETL 1.64 RI3DCLP+

Page 34 of 325

TR-151, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A Site."

Three Mile Island All Indications, With Length and Width Outage:

1R14 Tube#

Cal Probe 411 09 79 41 109 79 41 109 79 41 109 79 41 109 79 41 112 12 42 18 4

42 18 110 42 25 50 42 25 50 42 29 50 42 29 50 42 52 41 42 52 41 42 67 56 42 67 56 42 67 56 42 67 56 42 67 56 42 67 56 42 68 55 42 69 95 42 69 95 42 73 110 42 73 68 42 73 68 42 73 68 42 73 68 42 73 68 42 73 68 42 73 113 42 73 113 42 73 113 42 73 113 42 73 113 520HF 520HF 520HF 520HF 520HF 460PP 51OUL 520HF 520HF 520HF 520HF 520HF 51 OUL 51 OUL 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 540HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 17olt / Origin!

Degrees Percent 0.00 0

0.42 15 0.00 0

1.40 33 0.00 0

0.23 121 0.78 95 0.00 0

0.00 0

0.31 9

0.30 25 0.00 0

1.10 103 2.06 97 0.38 0.00 0.26 0.00 0.28 0.00 18 0

16 0

16 0

0.00 0

0.85 19 0.00 0

0.44 0.00 0.20 0.00 0.34 0.46 0.00 0.44 0.00 0.27 0.00 0.00 10 0

31 0

20 18 0

17 0

17 0

0 ID ID ID Location Code TSP - Offset A

frT P f"rTT "V

.A J,a I I-*

20 VOL ETL 0

CLP ETL 86 VOL ETL 0

CLP ETL 0

COD UTE 0 NQI LTE 0 NDF LTS 0

CLP ETL 8 VOL ETL ID 51 VOL ETL 0

CLP ETL 0

INR 01S 0

INR 02S ID 27 VOL ETL 0

CLP ETL ID 22 VOL ETL 0

CLP ETL ID 22 VOL ETL 0

CLP ETL 0

RIC ETL ID 30 VOL ETL 0

CLP ETL ID 33 TWD 15S 0

CLP ETL 0

VOL ETL 0

CLP ETL ID 33 VOL ETL ID 27 VOL ETL 0

CLP ETL 0

VOL UTS 0

CLP UTS 0

VOL UTS 0

CLP UTS 0 CLP UTS I.,'A 1.99 1.99 2.59 2.59

-0.49 8.11

-15.89 1.34 1.34 0.02 0.02 34.48 35.64 0.25 0.25 0.60 0.60 3.57 3.57 0.56 3.00 3.00 41.44

-0.36

-0.36 1.14 1.14 1.40 1.40

-5.25

-5.25

-0.52

-0.52 3.50 Axial Circ Dataset 0.12 0.14 R13DCLP+

R13DCLP+

0.12 0.14 RI3DCLP+

R13DCLP+

0.18 0.23 R13DCLP+

PlugMRP 510_Bobbi SpecInt 0.11 0.15 KEXP_+Pt KEXP_+Pt KEXP_+Pt 0.17 0.15 KEXP_+Pt 510 Bobbi 510_Bobbi KEXP_+Pt 0.11 0.10 KEXP_+Pt KEXP_+Pt 0.06 0.10 KEXP_+Pt KEXP_+Pt 0.17 0.10 KEXP_+Pt KEXP_+Pt KEXP_+Pt 0.10 0.15 KEXP_+Pt 540_Bobbi 0.11 0.14 KEXP_+Pt KEXP_+Pt 0.17 0.14 KEXP_+Pt KEXP_+Pt KEXP_+Pt 0.11 0.14 KEXP_+Pt Spec Int 0.14 0.17 SpecInt Spec Int 0.09 0.11 Specmnt 0.19 0.11 Spec int Page 35 of 325

TR-151, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A Site:

Three Mile Island All Indications, l4"ith Length and 1'7'"dth Outage:

IR]4 Volt / Origin/

Location Tube#

Cal Probe Degrees Percent Code TSP - Offset Axial Circ Dataset 42 73 113 S,,I11 0.39 15 0

VOL UTS 3.50 Spec int 42 73 113 520HF 0.24 8

0 VOL UTS 4.62 SpecInt 42 73 113 520HF 0.00 0

0 CLP UTS 4.62 0.09 0.06 SpecInt 42 74 67 520HF 0.00 0

0 CLP ETL 1.67 0.16 0.18 KEXP_+Pt 42 74 67 520HF 0.37 16 ID 22 VOL ETL 1.67 KEXP_+Pt 42 74 67 520HF 0.36 13 ID 15 VOL ETL 1.96 KEXP_+Pt 42 74 67 520HF 0.00 0

0 CLP ETL 1.96 0.16 0.16 KEXP_+Pt 42 74 67 520HF 0.51 15 ID 20 VOL ETL 2.67 KEXP_+Pt 42 74 67 520HF 0.00 0

0 CLP ETL 2.67 0.22 0.23 KEXP_+Pt 42 76 89 51OUL 5.42 183 0

IDC LTS 0.00 25.11 510_Bobbi 42 76 113 520HF 0.00 0

0 NDF LTS 0.00 25.11 SpecInt 42 89 68 520HF 0.00 0

0 CLP ETL 2.64 0.11 0.18 KEXP_+Pt 42 89 68 520HF 0.71 28 ID 63 VOL ETL 2.64 KEXP_+Pt 42 89 68 520HF 0.48 27 ID 58 VOL ETL 5.09 KEXP_-+Pt 42 89 68 520HF 0.00 0

0 CLP ETL 5.09 0.17 0.14 KEXP_+Pt 42 89 90 51OUL 0.25 18 ID 60 TWD UTS 0.60 510_Bobbi 42 89 113 520HF 0.00 0

0 CLP UTS 0.69 0.14 0.22 SpecInt 42 89 180 540HF 0.30 14 ID 47 TWD UTS 0.69 540_BobEx 42 89 113 520HF 0.56 21 0 VOL UTS 0.69 SpecInt 42 89 90 51OUL 0.22 91 0 NQI UTS 0.83 510_Bobbi 42 89 113 520HF 0.00 0

0 NDF UTS 0.90 SpecInt 42 89 180 540HF 0.14 77 0

NQI UTS 0.90 540_BobEx 42 101 73 520HF 0.00 0

0 CLP ETL

-1.49 0.16 0.18 KEXP_+Pt 42 101 73 520HF 1.30 28 0

VOL ETL

-1.49 KEXP_+Pt 42 108 108 540HF 0.29 20 0

BVC 15S 19.44 540_Bobbi 42 108 167 520HF 1.60 27 0

VOL 15S 20.04 R13DCLP+

42 108 167 520HF 0.00 0

0 CLP 15S 20.04 0.14 0.22 R13DCLP+

42 108 167 520HF 0.00 0

0 CLP 15S 27.02 0.09 0.16 R13DCLP+

42 108 167 520HF 0.36 22 0

VOL 15S 27.02 R13DCLP+

42 108 167 520HF 0.00 0

0 CLP 15S 30.08 0.14 0.11 R13DCLP+

42 108 167 520HF 0.22 11 0

VOL 15S 30.08 R13DCLP+

42 109 74 520HF 0.35 21 ID 36 VOL ETL 1.32 KEXP_+Pt 42 109 74 520HF 0.00 0

0 CLP ETL 1.32 0.12 0.14 KEXP_-+Pt 42 109 74 520HF 0.56 22 ID 40 VOL ETL 2.72 KEXP_+Pt 42 109 74 520HF 0.00 0

0 CLP ETL 2.72 0.12 0.14 KEXP_-+Pt 42 110 73 520HF 0.36 17 0 VOL ETL

-3.33 KEXP_+Pt 42 110 73 520HF 0.00 0

0 CLP ETL

-3.33 0.16 0.14 KEXP +Pt Page 36 of 325

TR-151, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A

_ie.

Three Mile island

.411 llndicationss, With LenTgth and JJ'id*h Outage:

1R14 Volt / Origin/

Location Tube#

Cal Probe Degrees Percent Code TSP - Offset Axial Circ Dataset 42 111 74 520HF 0.58 21 ID 36 VOL ETL 1.16 KEXP-+Pt 42 111 74 520HF 0.00 0

0 CLP ETL 1.16 0.06 0.09 KEXP_+Pt 42 112 73 520HF 0.00 0

0 CLP ETL

-1.32 0.21 0.19 KEXP_+Pt 42 112 73 520HF 0.41 18 0

VOL ETL

-1.32 KEXP_+Pt 42 112 73 520HF 0.00 0

0 CLP ETL 1.01 0.21 0.19 KEXP_+Pt 42 112 73 520HF 0.44 15 ID 20 VOL ETL 1.01 KEXP_+Pt 42 112 73 520HF 0.00 0

0 CLP ETL 1.38 0.32 0.28 KEXP_+Pt 42 112 73 520HF 2.50 30 ID 71 VOL ETL 1.38 KEXP_+Pt 42 112 73 520HF 0.00 0

0 RPD ETL 1.38 KEXP_+Pt 42 112 130 520HF 2.87 26 0

PID ETL 1.82 KEXP_-+Pt 42 112 73 520HF 0.00 0

0 CLP ETL 1.82 0.16 0.19 KEXP_+Pt 42 112 73 520HF 0.41 19 ID 30 VOL ETL 1.82 KEXP_+Pt 42 112 73 520HF 0.27 22 ID 40 VOL ETL 3.93 KEXP_+Pt 42 112 73 520HF 0.00 0

0 CLP ETL 3.93 0.21 0.14 KEXP_+Pt 42 114 108 540HF 0.28 146 0

INR 13S

-0.79 540_Bobbi 42 114 156 520HF 0.48 105 OD 8

TWD 13S

-0.72 SpecInt 42 114 156 520HF 0.28 99 OD 4 TWD 13S 0.61 SpecInt 42 114 108 540HF 0.43 129 0 NQI 13S 0.67 540_Bobbi 42 114 108 540HF 0.31 140 0

INR 15S 0.64 540_Bobbi 42 114 108 540HF 0.33 14 0

BVC 15S 34.62 540 Bobbi 42 114 108 540HF 4.64 176 0

DNT LTE 11.12 540_Bobbi 42 114 156 520HF 0.00 0

0 RIC UTS

-18.62 R13DCLP+

42 114 167 520HF 0.34 21 0

VOL UTS

-18.62 R13DCLP+

42 114 167 520HF 0.00 0

0 CLP UTS

-18.62 0.14 0.17 R13DCLP+

42 114 156 520HF 0.00 0

0 CLP UTS

-15.25 0.15 0.11 R13DCLP+

42 114 156 520HF 0.20 21 0

VOL UTS

-15.25 R13DCLP+

42 114 156 520HF 0.39 20 0

VOL UTS

-12.57 SpecInt 42 114 156 520HF 0.00 0

0 CLP UTS

-12.57 0.15 0.17 SpecInt 42 114 156 520HF 0.22 15 0

VOL UTS

-3.10 SpecInt 42 114 156 5201-IF 0.00 0

0 CLP UTS

-3.10 0.15 0.17 SpecInt 43 6

4 51OUL 0.16 105 0 NQI 07S 18.24 510_Bobbi 43 6 110 520HF 0.00 0

0 NDF 07S 18.24 SpecInt 43 6

4 51OUL 0.17 80 0

NQI 13S 33.08 510 Bobbi 43 6 110 520HF 0.00 0

0 NDF 14S

-2.92 SpecInt 43 27 53 510UL 1.71 95 0

INR 12S 35.12 510_Bobbi 43 36 52 51OUL 1.44 168 0

INR LTE 2.59 510_Bobbi 43 76 79 520HF 0.12 6

0 VOL ETL

-2.19 R13DCLP+

Page 37 of 325

TR-151, Revision 0 Appendix II Recordable Indications TMI-OTSG-A Three Mile Island Cal Tube#

43 76 79 43 82 110 43 82 113 43 98 89 43 107 108 43 111 156 43 I11 108 43 111 108 43 111 167 43 111 167 43 111 167 43 111 167 43 111 167 43 111 167 43 111 167 43 113 106 43 116 105 44 3

8 44 3 110 44 3

8 44 19 34 44 19 83 44 19 34 44 19 34 44 32 52 44 91 90 44 106 156 44 106 106 44 112 156 44 112 106 44 114 106 44 119 106 Probe 520HF 540HF 520HF 51OUL 540HF 520HF 540HF 540HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 51OUL 51OUL 51OUL 520HF 51OUL 520HF 520HF 520HF 520HF 51OUL 51OUL 520HF 51OUL 520HF 51OUL 51OUL 510UL V 'olt / Origin!

Degrees Percent 0.00 0

0.43 9

ID 30 0.00 0

0 0.34 81 OD 6

0.45 3

0 0.00 0

0 0.41 87 0

0.30 11 0

0.00 0

0 0.31 12 ID 16 0.00 0

0 0.17 12 0

0.00 0

0 0.59 21 0

0.00 0

0 2.68 176 0

4.11 179 0

0.28 93 0

0.00 0

0 0.36 98 0

0.21 35 0

0.19 12 0

0.00 0

0 0.27 22 0

1.12 70 0

0.22 87 0

0.23 96 OD 7

0.20 67 0

0.00 0

0 0.34 115 0

2.95 174 0

3.29 174 0

Page 38 of 325 Component:

All Indications, With Length and Jcidth Outage:

!R14 Code TWD NDF TWD INR NDF ADI BVC CLP VOL NDF VOL CLP VOL CLP DNT DNT NQI NDF INR INR PRA CLP VOL INR INR TWD NQI NDF NQI DNT DNT Location TSP - Offset 1J.

-2. 19 07S 37.61 08S

-2.39 03S 0.63 15S 37.09 lOS 7.40 lOS 7.40 15S 43.95 ETL 1.28 ETL 1.28 UTS

-6.74 UTS

-5.19 UTS

-5.19 UTS

-2.67 UTS

-2.67 LTE 10.81 LTE 10.17 LTE 3.12 LTE 3.12 LTE 8.56 ETL

-1.59 ETL

-1.15 ETL

-1.01 ETL

-1.01 03S 15.74 LTE 4.72 04S 0.70 04S 0.70 lOS 7.89 10S 7.89 LTE 11.03 LTE 11.29 Axial Circ Dataset 0.18 0.14 RI3DCLP+

540_Bobbi SpecInt 510 Bobbi 540_Bobbi SpecInt 540_Bobbi 540_Bobbi 0.09 0.11 R13DCLP+

R13DCLP+

R13DCLP+

R13DCLP+

0.14 0.16 R13DCLP+

R13DCLP+

0.19 0.16 R13DCLP+

510_Bobbi 510_Bobbi 510 Bobbi SpecInt 510 Bobbi KEXP_+Pt KEXP_+Pt 0.17 0.19 KEXP_+Pt KEXP_+Pt 510 Bobbi 510 Bobbi SpecInt 510_Bobbi Spec lnt 510 Bobbi 510 Bobbi 510 Bobbi

TR-151, Revision 0 Appendix I1 Recordable Indications Component:

TMI-OTSG-A Site:

Three Mile Island All Indications, JWith Length and W'lidth Outage:

1R14 Volt / Origin!

Location Tube#

Cal Probe Degrees Percent Code TSP - Offset Axial Circ Dataset 45 2

8 51OUL 0.16 79 0

INR 10S

-0.80 510_Bobbi 45 25 79 520HF 0.15 1

0 VOL ETL

-2.52 R13DCLP+

45 25 79 520HF 0.00 0

0 CLP ETL

-2.52 0.12 0.14 R13DCLP+

45 25 79 520HF 0.21 15 0

INR ETL

-0.52 R13DCLP+

45 28 53 51OUL 4.60 181 0

DNT 12S 28.77 510_Bobbi 45 33 50 520HF 0.14 35 0

VOL ETL

-0.36 KEXP_+Pt 45 33 50 520HF 0.00 0

0 CLP ETL

-0.36 0.11 0.15 KEXP_+Pt 45 81 79 520HF 0.31 18 0

VOL ETL

-0.82 R13DCLP+

45 81 79 520HF 0.00 0

0 CLP ETL

-0.82 0.12 0.14 RI3DCLP+

45 108 73 520HF 0.00 0

0 CLP ETL 0.13 0.16 0.19 KEXP_+Pt 45 108 73 520HF 1.01 27 ID 58 VOL ETL 0.13 KEXP_+Pt 45 108 73 520HF 0.00 0

0 CLP ETL 1.43 0.16 0.19 KEXP_+Pt 45 108 73 520HF 0.82 25 ID 51 VOL ETL 1.43 KEXP_+Pt 45 108 73 520HF 0.51 45 OD 96 VOL ETL 2.63 KEXP_+Pt 45 108 73 520HF 0.00 0

0 CLP ETL 2.63 0.11 0.14 KEXP_+Pt 45 113 108 540HF 0.34 7

0 BVC 15S 36.34 540_Bobbi 45 113 167 520HF 0.00 0

0 CLP UTS

-12.51 0.14 0.16 R13DCLP+

45 113 167 520HF 0.23 12 0

VOL UTS

-12.51 R13DCLP+

45 113 167 520HF 0.42 14 0

VOL UTS

-10.35 R13DCLP+

45 113 167 520HF 0.00 0

0 CLP UTS

-10.35 0.14 0.16 RI3DCLP+

45 117 105 51OUL 4.32 175 0

DNT LTE 10.74 510_Bobbi 46 19 7

51OUL 0.56 102 0

NQI LTE 8.29 510_Bobbi 46 19 110 520HF 0.00 0

0 NDF LTS

-15.71 SpecInt 46 19 110 520HF 0.00 0

0 NDF LTS 15.89 SpecInt 46 19 7

51OUL 0.21 121 0 NQI LTS 15.89 510_Bobbi 46 20 8

51OUL 0.42 107 0

INR LTE 7.53 510_Bobbi 46 20 8

51OUL 0.47 100 0

INR LTE 7.86 510_Bobbi 46 27 50 520HF 0.00 0

0 CLP ETL 0.52 0.11 0.10 KEXP_+Pt 46 27 50 520HF 0.45 15 ID 20 VOL ETL 0.52 KEXP_+Pt 46 27 50 520HF 0.49 19 ID 30 VOL ETL 0.81 KEXP_+Pt 46 27 50 520HF 0.00 0

0 CLP ETL 0.81 0.14 0.17 KEXP_+Pt 46 27 50 520HF 0.29 16 ID 22 VOL ETL 1.20 KEXP_+Pt 46 27 50 5201HIF 0.00 0

0 CLP ETL 1.20 0.11 0.10 KEXP_+Pt 46 27 50 520HF 0.36 24 ID 47 VOL ETL 1.51 KEXP +Pt Page 39 of 325

TR-151, Revision 0 Appendix II Recordable Indications C'ompone7t.:

TMI-OTSG-A Site.:

Three MAie Island All Indications, W-*ith Length and Width Outage.:

1R14 Tube#

Cal Probe 16 27" 50

  • i*

./

.)u 46 52 41 46 59 56 46 59 56 46 61 42 46 61 160 46 71 85 46 72 67 46 72 67 46 72 67 46 72 67 46 72 67 46 72 67 46 72 67 46 72 67 46 80 67 46 80 67 46 80 67 46 80 67 46 87 68 46 87 68 46 87 68 46 87 68 46 88 110 46 88 123 46 88 123 46 89 68 46 89 68 46 104 73 46 104 73 46 104 73 46 104 73 46 106 131 46 106 106 520HF 51OUL 520HF 520HF 51OUL 520HF 51OUL 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 540HF 520HF 520HF 520HF 520HF 520HF 520HF 520BF 520HF 540HF 51OUL Volt / Origin!

Degrees Percent 0.00 0

3.94 185 0.72 24 0.00 0

0.84 86 0.00 0

0.22 105 0.43 28 0.00 30 0.54 15 0.00 0

0.33 11 0.00 0

0.00 0

0.38 17 0.59 23 0.00 34 0.00 0

0.46 15 0.36 20 0.00 0

0.47 30 0.00 0

0.47 10 0.36 13 0.00 0

0.35 17 0.00 0

0.35 0.00 0.33 0.00 19 0

14 0

0.42 4

0.59 6

Location Code TSP - Offset 0

CLP ETL 0

DNT 06S ID 47 VOL ETL 0

CLP ETL 0

ADI 02S 0 NDF 03S 0

INR UTS ID 63 SCI ETL 0

ARC ETL ID 20 VOL ETL 0

CLP ETL ID 11 VOL ETL 0

CLP ETL 0

CLP ETL ID 25 VOL ETL ID 43 SCI ETL 0

ARC ETL 0

CLP ETL ID 20 VOL ETL ID 33 VOL ETL 0

CLP ETL ID 71 VOL ETL 0

CLP ETL ID 33 TWD 15S 0

VOL UTS 0

CLP UTS ID 25 VOL ETL 0

CLP ETL ID 30 VOL ETL 0

CLP ETL ID 17 VOL ETL 0

CLP ETL ID 0

INR 15S 20 TWD 15S 1.51 9.09 0.08 0.08 33.85

-5.15 1.77 2.63 2.63 3.55 3.55 4.39 4.39 4.75 4.75 0.75 0.75 1.91 1.91 2.69 2.69 3.26 3.26 30.21

-16.62

-16.62 2.19 2.19 2.31 2.31 2.97 2.97 33.38 33.76 Axial Circ Dataset 0.17 0.15 KEXP_+Pt 510 Bobbi KEXP_+Pt 0.05 0.20 KEXP-+Pt 510 Bobbi SpecInt 510_Bobbi KEXP_+Pt 0.16 KEXP-+Pt KEXP_+Pt 0.16 0.18 KEXP-+Pt KEXP_+Pt 0.20 0.18 KEXP-+Pt 0.20 0.18 KEXP_+Pt KEXP-+Pt KEXP_+Pt 0.18 KEXP_+Pt 0.16 0.14 KEXP_+Pt KEXP_+Pt KEXP-+Pt 0.12 0.09 KEXP_+Pt KEXP-+Pt 0.12 0.18 KEXP_+Pt 540_Bobbi RI 3DCLP+

0.15 0.22 RI3DCLP+

KEXP-+Pt 0.17 0.14 KEXP-+Pt KEXP-+Pt 0.11 0.14 KEXP-+Pt KEXP_+Pt 0.11 0.14 KEXP +Pt 540_BobEx 510 Bobbi Page 40 of 325

TR-151, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A Site:

Three Mile Island All IndCications, With Length and Wi17drh Out'age:

1R14 Tube#

Cal Probe 46 114 106 47 13 79 47 15 33 47 15 33 47 39 50 47 39 50 47 63 113 47 63 160 47 81 86 47 84 110 47 84 113 47 84 113 47 89 67 47 89 67 47 117 105 47 121 105 48 20 33 48 20 33 48 28 50 48 28 50 48 28 50 48 28 50 48 47 50 48 47 50 48 56 42 48 56 160 48 58 56 48 58 56 48 60 56 48 60 56 51OUL 520HF 520HF 520HF 520HF 520HF 540HF 520HF 51OUL 540HF 520HF 520HF 520HF 520HF 51OUL 510UL 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 51OUL 520HF 520HF 520HF 520HF 520HF V,'olt / Origin/

Degrees Percent 3.77 0.08 0.16 0.00 0.00 0.24 0.79 0.00 6.38 0.41 0.34 0.00 0.00 0.36 3.11 3.31 0.82 0.00 0.20 0.00 0.33 0.00 0.39 0.00 0.57 0.00 0.28 0.00 0.33 0.00 176 146 38 0

0 7

7 0

183 8

14 0

0 13 168 171 25 0

17 0

16 0

13 0

87 0

19 0

21 0

0 0

0 0

0 0

ID 23 0

0 ID 27 0

0 0

ID 15 0

0 0

0 0

0 0

0 0

0 0

0 ID 30 0

0 0

Location Code TSP - Offset DNT LTE 10.91 INR ETL

-1.27 VOL ETL

-0.40 CLP ETL

-0.40 CLP ETL

-0.71 VOL ETL

-0.71 TWD 03S 27.62 NDF 04S

-12.38 DNT 15S 2.76 TWD 15S 39.41 VOL UTS

-6.70 CLP UTS

-6.70 CLP ETL 1.99 VOL ETL 1.99 DNT LTE 10.86 DNT LTE 10.95 VOL ETL

-0.18 CLP ETL

-0.18 VOL ETL

-1.39 CLP ETL

-1.39 VOL ETL

-0.27 CLP ETL

-0.27 VOL ETL

-0.45 CLP ETL

-0.45 ADI 14S 20.02 NDF 15S

-14.98 VOL ETL 0.10 CLP ETL 0.10 VOL ETL

-5.76 CLP ETL

-5.76 Axial Circ Dataset 510_Bobbi R13DCLP+

KEXP_+Pt 0.10 0.15 KEXP-+Pt 0.11 0.10 KEXP-+Pt KEXP_+Pt 540_Bobbi SpecInt 510 Bobbi 540_Bobbi SpecInt 0.09 0.17 SpecInt 0.18 0.16 KEXP-+Pt KEXP_+Pt 510_Bobbi 510_Bobbi KEXP-+Pt 0.10 0.19 KEXP-+Pt KEXP_+Pt 0.11 0.10 KEXP-+Pt KEXP-+Pt 0.11 0.10 KEXP-+Pt KEXP_+Pt 0.11 0.15 KEXP_+Pt 510 Bobbi Spec Int KEXP_+Pt 0.17 0.10 KEXP_+Pt KEXP_+Pt 0.11 0.10 KEXP -+Pt Page 41 of 325

TR-151, Revision 0 Appendix II Recordable Indications C0om7ponent:

TMI-OTSG-A Site:

Three Mile Island All Indications, With Length and Width Outage:

1R14 Tube#

Cal Probe 48 65 55 48 65 55 48 66 42 48 66 133 48 66 160 48 78 67 48 78 67 48 85 134 48 85 86 48 92 67 48 92 67 48 118 108 48 118 108 48 118 156 48 118 167 48 118 167 48 118 156 48 118 156 48 118 156 48 118 156 48 118 156 48 118 156 48 118 156 48 118 156 48 119 106 48 121 106 48 121 156 48 121 106 48 123 14 49 1

8 49 1 110 49 23 117 49 23 121 49 23 121 520HF 520HF 510UL 520HF 520HF 520HF 520HF 520HF 51OUL 520HF 520HF 540HF 540HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 51OUL 51OUL 520HF 51OUL 460PP 51 0UL 520HF 540HF 520HF 520HF Volt / Origin/

Degrees Percent 0.00 0

0.41 18 0.71 92 0.00 0

0.00 0

0.00 0

0.22 14 0.00 0

0.68 67 0.00 0

0.40 16 0.40 0.26 0.00 0.32 0.00 0.38 0.00 0.23 0.00 0.00 0.34 0.00 0.16 6

6 0

11 0

18 0

24 0

0 15 0

10 4.34 174 0.12 90 0.00 0

3.11 173 0.15 136 0.47 96 0.00 0

0.36 7

0.00 0

0.31 10 Location Code TSP - Offset 0

CPI D E'rT ID 27 VOL ETL ID 0

NQI LTE 0 NDF LTE 0 RIC LTS 0

CLP ETL 17 VOL ETL 0 NDF LTS 0 NQI LTS 0

CLP ETL ID 22 VOL ETL ID 20 0

0 0

0 0

0 0

0 0

0 0

0 TWD BVC RIC VOL CLP VOL CLP VOL CLP CLP VOL CLP VOL 14S 14S 15S 15S 15S 15S 15S 15S 15S 15S 15S 15S 15S 0 DNT LTE 0

0 0

NQI 12S NDF 12S DNT LTE 0

AOD UTE 0 NQI LTE 0

NDF LTS 0

0 0

BVC 15S CLP UTS VOL UTS n '70 v. ju 0.78 3.36 3.36

-20.64 3.03 3.03 2.91 2.91 2.82 2.82 29.54 30.46

-12.30

-12.30

-12.30

-5.84

-5.84

-4.98

-4.98

-1.21

-1.21 4.54 4.54 10.83 0.36 0.36 10.22

-0.16 14.17

-9.83 42.55

-3.77

-3.77 Axial Circ Dataset

,i 0.V.

17 KE t

L KEXP_+Pt 510_Bobbi SpecInt SpecInt 0.22 0.18 KEXP_+Pt KEXP_+Pt LTS_+Pt 510_Bobbi 0.16 0.18 KEXP_+Pt KEXP_+Pt 540_Bobbi 540_Bobbi R13DCLP+

R13DCLP+

0.14 0.11 R13DCLP+

SpecInt 0.15 0.11 SpecInt SpecInt 0.10 0.17 SpecInt 0.15 0.11 SpecInt SpecInt 0.15 0.11 SpecInt SpecInt 510 Bobbi 510 Bobbi SpecInt 510_Bobbi Plug_MRP 510 Bobbi SpecInt 540_Bobbi 0.14 0.11 RI 3DCLP+

R13DCLP-+

Page 42 of 325

TR-151, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A Site:

Three Mile Island All Indications, W4ith Length and lU'7dth Outage:

1R14 Volt / Origin/

Degrees Percent 40, 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 Tube#

73 160 73 160 73 113 73 160 73 160 73 160 73 160 82 110 82 110 82 110 82 123 82 123 82 123 82 123 82 123 82 123 1 121 1 121 1 121 1 121 1 121 1 121 1 121 1 121 1 117 1 121 1 121 1 121 1 121 1 121 1 121 15 33 15 33 15 33 15 33 18 79 18 79 18 79 18 79 0

0 ID 37 0

0 0

0 0

0 0

0 0

0 0

0 0

Cal Probe 5n1)n*

52vHF 520HF 540HF 520HF 520HF 520HF 520HF 540HF 540HF 540HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 540HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 0.00 0.26 0.73 0.00 1.49 0.00 0.41 0.24 0.20 0.17 0.00 0.28 0.00 0.04 0.00 0.36 0.00 0.12 0.18 0.00 0.00 0.11 0.36 0.00 0.55 0.00 0.39 0.23 0.00 0.17 0.00 0.28 0.00 0.00 0.22 0.00 0.26 0.44 0.00 Location TSP - Offset UTS 3.66 UTS 3.66 UTS 5.00 UTS 5.65 UTS 5.65 UTS 6.41 UTS 6.41 0

9 11 0

30 0

19 10 7

15 0

10 0

29 0

20 0

7 18 0

0 10 11 0

5 0

15 21 0

12 0

25 0

0 30 0

17 28 0

Code CLP VOL TWD CLP VOL CLP VOL INR INR INR CLP VOL CLP VOL CLP VOL CLP VOL VOL CLP CLP VOL VOL CLP TWD CLP VOL VOL CLP VOL CLP VOL CLP CLP VOL CLP VOL VOL CLP Axial Circ Dataset 0.14 0.17 RI3DCLP+

R13DCLP+

540_Bobbi 0.14 0.22 R13DCLP+

R13DCLP+

0.14 0.22 RI3DCLP+

R13DCLP+

540_Bobbi 540_Bobbi 540_Bobbi 0.19 0.11 R13DCLP+

R13DCLP+

0.10 0.11 R13DCLP+

R13DCLP+

0.19 0.16 R13DCLP+

R13DCLP+

0.09 0.11 R13DCLP+

R13DCLP+

RI3DCLP+

0.14 0.11 R13DCLP+

0.14 0.17 R13DCLP+

R13DCLP+

R13DCLP+

0.09 0.11 R13DCLP+

540 Bobbi 0.09 0.11 R13DCLP+

R13DCLP+

R 13DCLP+

0.14 0.11 R13DCLP+

R13DCLP+

0.19 0.17 R13DCLP+

KEXP_+Pt 0.10 0.19 KEXP_+Pt 0.10 0.14 KEXP_+Pt KEXP_+Pt 0.11 0.18 R13DCLP+

R13DCLP+

RI3DCLP+

0.16 0.18 R13DCLP+

Page 43 of 325 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 ID 17 0

0 0

0 0

0 15S 15S 15S UTS UTS UTS UTS UTS UTS 14S 14S 14S 14S 14S 14S 14S 14S 14S 14S 14S 14S 14S 14S 14S ETL ETL ETL ETL ETL ETL ETL ETL 39.84 41.42 42.33

-6.74

-6.74

-5.15

-5.15

-0.07

-0.07 7.38 7.38 8.98 8.98 9.48 9.48 9.83 9.83 10.12 10.25 10.25 10.56 10.56 15.01 15.01

-0.94

-0.94

-0.10

-0.10

-2.45

-2.45

-1.25

-1.25

TR-151, Revision 0 Appendix II Recordable Indications TMI-OTSG-A Three Mile Island Tube#

Cal Probe 50 21 79 50 21 79 50 21 79 50 21 79 50 21 79 50 21 79 50 25 8

50 36 52 50 36 114 50 36 52 50 41 50 50 41 50 50 60 79 50 60 79 50 75 85 50 75 85 50 76 79 50 76 79 50 101 110 50 101 85 50 102 110 50 102 123 50 102 123 50 119 79 50 119 79 50 119 79 50 119 79 50 119 105 50 123 14 51 2 110 51 2 110 51 2 110 51 2 110 520HF 520HF 520HF 520HF 520HF 520HF 51OUL 51OUL 520HF 51OUL 520HF 520HF 520HF 520HF 51OUL 510UL 520HF 520HF 540HF 51OUL 540HF 520HF 520HF 520HF 520HF 520HF 520HF 51 OUL 460PP 520HF 520HF 520HF 520HF Volt / Origin!

Degrees Percent 0.15 18 0.00 0

0.42 23 0.00 0

0.12 7

0.00 0

4.49 177 0.19 115 0.00 0

0.14 152 0.28 27 0.00 0

0.62 26 0.00 90 10.90 183 11.32 183 0.53 22 0.00 0

0.64 4

0.60 5

0.64 5

0.48 21 0.00 0

0.26 0.00 0.85 0.00 2.96 22 0

27 0

172 0.10 107 1.08 0.00 0.00 0.50 23 0

0 20 ID ID 0

0 43 0

5 0

Location Code TSP - Offset VOL ETL CLP ETL VOL ETL CLP ETL VOL ETL CLP ETL 0

DNT UTS 0

0 0

NQI 04S NDF 05S INR LTE 0

VOL ETL 0

CLP ETL 0

VOL ETL 0

CLP ETL 0 DNT 09S 0 DNT 11S 0

0 VOL ETL CLP ETL 0

INR 15S ID 17 TWD 15S ID 17 0

0 0

0 0

0 0

TWD 15S VOL 15S CLP 15S VOL ETL CLP ETL VOL ETL CLP ETL DNT LTE

-1.88

-1.88 0.98 0.98 3.09 3.09 4.44 22.59

-16.41 2.39

-0.23

-0.23

-1.22

-1.22 7.30 33.21

-2.28

-2.28 15.46 15.46 16.32 16.62 16.62

-1.91

-1.91

-1.58

-1.58 11.03 0

AOD UTE

-0.20 0

0 0

0 VOL 15S CLP 15S CLP 15S VOL 15S

-0.53

-0.53 2.87 2.87 Axial Circ Dataset R13DCLP+

0.11 0.14 R13DCLP+

R13DCLP+

0.11 0.14 R13DCLP+

R13DCLP+

0.11 0.14 R13DCLP+

510_Bobbi 510 Bobbi SpecInt 510_Bobbi KEXP-+Pt 0.15 0.15 KEXP_+Pt R13DCLP+

0.11 0.19 R13DCLP+

510 Bobbi 510_Bobbi R13DCLP+

0.18 0.18 R13DCLP+

540_BobEx 510_Bobbi 540_Bobbi R13DCLP+

0.09 0.17 R13DCLP+

RI3DCLP+

0.24 0.23 R13DCLP+

R13DCLP+

0.18 0.18 R13DCLP+

510 Bobbi PlugMRP R13DCLP+

0.19 0.22 R13DCLP+

0.14 0.17 R13DCLP+

R13DCLP+

Page 44 of 325 Co17])oM1e71:

Site."

All Indications, Wl'ith Length and WJ'idth Outage:

1R14

TR-151, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A Site:

Three Mile Island All Idclications, 1ith Lemgdh and W'idt/h Outage:

1R114 Volt / Origin!

Degrees Percent 0.4A 0.59 0.39 0.00 0.33 0.56 0.00 0.00 0.00 0.38 0.43 0.00 0.00 0.46 10 24 4

0 12 19 0

0 0

3 28 0

0 15 Cal Tube#

2 117 2 110 2 117 2 110 2 117 2 110 2 110 2 110 2 110 2 117 2 121 2 121 2 121 2 121 51 51 51 51 51 51 51 51 51 51 51 51 51 51 ID) 33 0

0 0

0 0

0 0

0 0

0 0

0 0

Location Code TSP - Offset TWD 15S 2.93 VOL 15S 3.13 INR 15S 3.13 CLP 15S 3.13 BVC 15S 20.10 VOL 15S 20.31 CLP 15S 20.31 RIC 15S 29.78 RIC 15S 39.90 INR 15S 39.93 VOL UTS

-17.15 CLP UTS

-17.15 CLP UTS

-6.85 VOL UTS

-6.85 Probe 5 40 -IF 520HF 540HF 520HF 540HF 520HF 520HF 520HF 520HF 540HF 520HF 520HF 520HF 520HF 520HF 520HF 51OUL 51OUL 51OUL 51OUL 540HF 520HF 520HF 520HF 51OUL 51OUL 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 0

0 0

INR LTE INR LTE INR LTE ID 23 TWD 10S 0

INR 10S ID 10 VOL ETL 0

CLP ETL 0

NDF 02S 0 ADI 02S 0

NQI 05S OD 5 TWD 05S 0 VOL ETL 0

CLP ETL ID 40 VOL ETL 0

CLP ETL ID ID 0

30 54 0

CLP ETL VOL ETL VOL ETL CLP ETL

-0.26

-0.26 10.15 13.85 16.22 14.22 14.22 2.65 2.65 8.80 8.80 0.61 0.81

-0.12

-0.12 1.13 1.13 3.04 3.04 3.94 3.94 Axial Circ Dataset 540 Bobbi R133DCLP+

540_Bobbi 0.14 0.17 R13DCLP+

540_Bobbi SpecInt 0.09 0.17 SpecInt R13DCLP+

RI 3DCLP+

540_Bobbi R13DCLP+

0.14 0.11 R113DCLP+

0.10 0.11 R13DCLP+

R1 3DCLP+

KEXP_+Pt 0.12 0.18 KEXP_+Pt 510 Bobbi 510 Bobbi 510_Bobbi 510_Bobbi 540_BobEx KEXP_+Pt 0.11 0.14 KEXP_+Pt Specmnt 510_Bobbi 510 Bobbi SpecInt KEXP_+Pt 0.11 0.15 KEXP_+Pt KEXP_+Pt 0.11 0.15 KEXP_+Pt 0.17 0.15 KEXP +Pt KEXP_-Pt KEXP +Pt 0.22 0.15 KEXP +Pt Page 45 of 325 0.00 0.52 0.36 0.00 0

19 26 0

0 VOL ETL 0

CLP ETL 51 16 34 51 16 34 51 51 51 19 8

19 8

19 8

0.49 24 0.00 0

0.44 97 0.54 104 0.23 119 0.54 7

0.54 2

0.37 10 0.00 0

0.00 0

0.68 88 0.19 57 0.31 75 0.24 40 0.00 0

0.50 22 0.00 0

51 23 8

51 23 117 51 45 51 51 45 51 51 48 114 51 48 53 51 58 42 51 58 160 51 61 56 51 61 56 51 65 56 51 65 56 51 51 51 51 68 55 68 55 68 55 68 55

TR-151, Revision 0 Appendix II Recordable Indications Component":

TMI-OTSG-A Site.

Three Mile Island

.ll Indications, 117ith Length and It idth Ou)age:

1R14 Tube#

Cal Probe C5 71 C

jI/iJu 51 73 56 51 78 68 51 78 68 51 84 68 51 84 68 51 84 68 51 84 68 51 84 68 51 84 68 51 92 110 51 92 110 51 92 113 51 92 113 51 92 113 51 92 110 51 109 74 51 109 74 51 110 12 51 112 12 51 115 106 52 12 8

52 17 33 52 17 33 52 48 52 52 65 79 52 65 55 52 65 55 52 65 55 52 65 55 52 65 55 52 65 55 52 95 59 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 540HF 540HF 520HF 520HF 520HF 540HF 520HF 520HF 460PP 460PP 51OUL 51OUL 520HF 520HF 510UL 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF Volt / Origin!

Degrees Percent 1.06 28 0.00 0

0.41 20 0.00 0

0.44 0.00 0.47 0.00 0.73 0.00 0.26 0.33 0.00 0.00 0.00 0.19 21 0

22 90 33 0

5 7

0 0

0 7

0.74 29 0.00 0

Location Code TSP - Offset ID 63 VOL ETL 0

CLP ETL ID 33 VOL ETL 0

CLP ETL ID 36 0

ID 40 0

ID 86 0

0 0

0 0

0 0

ID 67 0

VOL ETL CLP ETL VOL ETL CLP ETL VOL ETL CLP ETL BVC 13S BVC 13S NDF 14S NDF 14S NDF 14S BVC 14S VOL ETL CLP ETL 0.12 0.12 1.91 1.91 2.69 2.69 3.80 3.80 4.04 4.04 27.20 32.54

-8.80

-3.46 5.68 5.68 2.72 2.72 0.00 0

0 OBS UTE 0.00 0.00 0

0 OBS UTE 0.00 2.33 172 0

INR LTE 10.41 0.24 94 0

INR LTE 9.31 0.21 19 0.00 0

0.86 177 0.79 23 0.88 20 0.00 0

0.00 0

0.48 10 0.45 19 0.00 0

ID 32 VOL ETL 0

CLP ETL 0

INR 08S 0

0 0

0 0

0 0

PID ETL VOL ETL CLP ETL CLP ETL VOL ETL VOL ETL CLP ETL 0.61 21 ID 36 VOL ETL 0.72 0.72 30.82

-2.41

-2.41

-2.41

-1.13

-1.13

-0.54

-0.54 0.00 Axial Circ Dataset KEXP +Pt 0.17 0.19 KEXP-+Pt KEXP-+Pt 0.18 0.14 KEXP_+Pt KEXP_+Pt 0.12 0.18 KEXP-+Pt KEXP_+Pt 0.18 0.18 KEXP_+Pt KEXP_-+Pt 0.18 0.23 KEXP_+Pt 540 Bobbi 540_Bobbi SpecInt Speclnt SpecInt 540_Bobbi KEXP-+Pt 0.12 0.14 KEXP_+Pt PlugMRP PlugMRP 510 Bobbi 510 Bobbi KEXP_+Pt 0.15 0.15 KEXP-+Pt 510 Bobbi KEXP-+Pt KEXP-+Pt 0.22 0.20 KEXP-+Pt 0.17 0.20 KEXP_+Pt KEXP_+Pt KEXP_--Pt 0.17 0.20 KEXP -Pt KEXP +Pt Page 46 of 325

TR-151, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A Site:

Three Mile Island All Indicationss, With Length amn Width C)taage:

IRM4 Tube#

Cal Probe 95 Z5ý9-5201I 52 101 86 52 110 73 52 110 73 52 110 73 52 110 73 52 111 108 52 118 79 52 118 79 52 123 156 52 123 105 53 15 34 53 15 34 53 17 34 53 17 34 53 25 34 53 25 34 53 29 51 53 29 51 53 29 51 53 29 51 53 46 138 53 46 138 53 46 138 53 46 138 53 46 51 53 46 51 53 46 123 53 51 50 53 51 50 53 51 50 53 51 50 53 62 56 51OUL 520HF 520HF 520HF 520HF 540HF 520HF 520HF 520HF 51OUL 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520PI 520PI 520P1 520PI 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF Volt / Origin!

Degrees Percent 0.00 0

2.73 185 1.03 0.00 1.72 0.00 22 0

31 39 0.47 4

0.27 12 0.00 0

0.00 0

0.10 77 0.00 0

0.15 15 0.25 25 0.00 0

0.38 30 0.00 0

0.48 19 0.00 0

0.00 0

0.36 13 0.82 22 0.00 0

3.52 41 0.00 38 0.00 31 3.14 44 2.68 43 0.00 0

0.18 34 0.33 14 0.00 0

0.00 90 0

0 ID 76 0

Location Code TSP - Offset 0 CLP ETL 0 DNT LTE VOL ETL CLP ETL SCI ETL ARC ETL 0

INR 15S 0 VOL ETL 0

CLP ETL ID ID ID ID OD OD ID 0

0 0

20 NDF 12S NQI 12S CLP ETL VOL ETL 51 VOL ETL 0

CLP ETL 0

VOL ETL 0

CLP ETL 30 VOL ETL 0

CLP ETL 0

CLP ETL 15 VOL ETL 0

VOL ETL 0

CLP ETL 98 SCI ETL 0

ARC ETL 0

ARC ETL 97 SCI ETL 0 PID ETL 0

CLP ETL 0 VOL ETL 17 VOL ETL 0

CLP ETL 0

CLP ETL 0.00 16.45

-2.98

-2.98 2.71 2.71 20.71

-1.14

-1.14

-0.19

-0.19 2.63 2.63 2.95 2.95

-0.28

-0.28 2.09 2.09 2.94 2.94

-3.92

-3.92

-1.49

-1.49

-1.43

-1.43

-1.43

-0.30

-0.30 1.89 1.89

-1.02 Axial Circ Dataset 0.22 0.18 KEXP-+Pt 510 Bobbi KEXP-+Pt 0.11 0.19 KEXP_+Pt KEXP-+Pt 0.21 KEXP-+Pt 540_Bobbi R13DCLP+

0.18 0.23 R13DCLP+

SpecInt 510_Bobbi 0.12 0.14 KEXP-+Pt KEXP-+Pt KEXP-+Pt 0.18 0.18 KEXP-+Pt KEXP_+Pt 0.12 0.14 KEXP-+Pt KEXP-+Pt 0.11 0.14 KEXP-+Pt 0.17 0.14 KEXP-+Pt KEXP-+Pt Postln_+Pt 0.14 0.17 Postln_+Pt PostIn_-+Pt 0.20 Postln_+Pt 0.17 KEXP_+Pt KEXP_-+Pt KEXP_+Pt 0.14 0.15 KEXP-+Pt KEXP_+Pt KEXP-+Pt 0.17 0.10 KEXP -+Pt 0.17 0.15 KEXP -+Pt Page 47 of 325

TR-151, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A Site:

Tbree Mile Island All Indications, 14ith Length and Width Outage:

IR14 Tube#

Cal Probe u/_

J6 53 62 56 53 62 56 53 70 41 53 71 42 53 72 41 53 88 85 53 92 59 53 92 59 53 92 59 53 92 59 53 123 108 53 123 167 53 123 167 54 4

7 54 4

7 54 4 110 54 4 121 54 7

8 54 7 110 54 34 50 54 34 50 54 34 50 54 34 50 54 55 41 54 56 42 54 57 41 54 65 41 54 65 41 54 65 144 54 66 42 54 66 144 520HF 520HF 520HF 51OUL 51OUL 51OUL 51OUL 520HF 520HF 520HF 520HF 540HF 520HF 520HF 51OUL 51OUL 520HF 520HF 51OUL 520HF 520HF 520HF 520HF 520HF 51OUL 51OUL 51OUL 51 OUL 51OUL 520HF 51OUL 520HF Volt / Origin/

Degrees Percent 0.40 18 0.31 22 0.00 0

4.95 170 11.20 169 5.70 171 0.10 83 0.19 31 0.00 0

0.19 25 0.00 0

3.24 176 0.17 29 0.00 0

0.29 111 0.38 82 0.00 0

0.00 0

0.22 83 1.25 103 0.38 25 0.00 0

1.10 30 0.00 0

4.06 178 10.56 174 9.15 174 3.21 180 0.79 99 0.00 0

3.70 176 0.00 0

Location Code TSP - Offset 0

V*OLr

,,L ID 40 VOL ETL 0

CLP ETL 0

DNT LTS 0 DNT LTS 0

DNT LTS 0

INR LTS ID 76 VOL ETL 0

CLP ETL ID 51 VOL ETL 0

CLP ETL 0

DNT LTE 0 VOL UTS 0

CLP UTS OD 6

TWD 10S 0

NQI LTE 0 RIC LTE 0

NDF LTE 0

NQI 09S OD 12 TWD 09S 0

VOL ETL 0 CLP ETL ID 71 VOL ETL 0

CLP ETL 0

DNT LTS 0

DNT LTS 0 DNT LTS 0 DNT LTS 0 NQI LTS 0

NDF LTS 0

DNT LTS 0 NDF LTS

-1.02 1.91 1.91

-0.06 0.00

-0.08 3.15 2.12 2.12 3.70 3.70 9.63

-18.25

-18.25

-0.78 8.81 8.81 8.81

-0.45

-0.38

-0.03

-0.03 4.39 4.39

-0.13 0.00

-0.08

-0.10 1.05 1.05 0.00 1.10 Axial Circ Dataset KEXP_+Pt 0.17 0.15 KEXP_+Pt 510_Bobbi 510 Bobbi 510_Bobbi 510 Bobbi KEXP-+Pt 0.16 0.18 KEXP_-+Pt KEXP_+Pt 0.16 0.18 KEXP_+Pt 540_Bobbi RI3DCLP+

0.09 0.16 R13DCLP+

510 Bobbi 510_Bobbi SpecInt SpecInt 510 Bobbi SpecInt KEXP_+Pt 0.11 0.10 KEXP_-+Pt KEXP_-+Pt 0.11 0.15 KEXP_+Pt 510_Bobbi 510 Bobbi 510 Bobbi 510 Bobbi 510 Bobbi LTS- +Pt 510 Bobbi LTS +Pt Page 48 of 325

TR-I 51, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A Site:

Three Mile Island

.411 Indications, 1ith Length and Width Outage:

1R14 Tube#

Cal Probe CA An 54 71 41 54 72 42 54 73 41 54 88 59 54 104 113 54 104 85 55 1

8 55 13 8

55 13 110 55 19 8

55 21 33 55 21 33 55 34 77 55 34 77 55 34 77 55 34 77 55 54 47 55 55 42 55 56 41 55 57 42 55 58 41 55 65 42 55 66 41 55 69 79 55 69 79 55 73 42 Z" 1 A'T TT 51OUL 510UL 51OUL 520HF 520HF 51OUL 51OUL 51OUL 520HF 51OUL 520HF 520HF 520HF 520HF 520HF 520HF 51OUL 510UL 51 OUL 51OUL 51OUL 51OUL 51OUL 520HF 520HF 51OUL V 'olt / Originl' Degrees Percent u.,.*

iz.

4.92 7.18 4.71 0.32 0.76 0.33 0.67 0.25 0.00 2.10 0.00 0.64 0.00 0.30 0.00 0.18 5.87 20.32 25.40 14.11 4.82 3.78 3.35 0.11 0.00 4.67 166 167 170 168 148 68 105 75 0

177 35 20 0

19 0

3 175 172 173 172 175 176 180 9

0 167 OD ID ID Location Code TSP - Offset 0

NQI LTS 0 DNT LTS 0

DNT LTS 0

DNT LTS 0

INR ETL 14 TWD 09S 0 NQI 09S 0

INR LTE 0 NQI LTE 0 NDF LTS 0 INR LTE 0

ARC ETL 35 SCI ETL 0

CLP ETL 30 VOL ETL 0

CLP ETL I

VOL ETL 0

DNT LTS 0

DNT LTS 0

DNT LTS 0 DNT LTS 0

DNT LTS 0

DNT LTS 0

DNT LTS 0

VOL ETL 0

CLP ETL 0

DNT LTS I.I0 0.02 0.00 0.00

-0.42 0.63 0.73 19.79 9.22

-14.78 4.87 1.12 1.12 0.28 0.28 0.67 0.67

-0.08 0.00

-0.02 0.00

-0.06 0.00

-0.15

-1.05

-1.05 0.00 Axial Circ Dataset 510 Bobbi 510 Bobbi 510_Bobbi 510 Bobbi KEXP_+Pt Specmnt 510 Bobbi 510 Bobbi 510 Bobbi SpecInt 510 Bobbi 0.19 KEXP_+Pt KEXP_+Pt 0.05 0.14 KEXP_+Pt KEXP_+Pt 0.13 0.17 KEXP_+Pt KEXP_+Pt 510 Bobbi 510 Bobbi 510 Bobbi 510 Bobbi 510 Bobbi 510 Bobbi 510_Bobbi R13DCLP+

0.11 0.14 R13DCLP+

510 Bobbi Page 49 of 325

TR-151, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A S~ite:

Three Mile Island All Indications, k'ith Length and Jt'idth Outage:

1R14 Tube#

Cal Probe 55 74 41 5iOUL 55 111 104 55 120 55 120 55 120 55 120 55 120 55 120 55 120 55 120 55 120 55 120 55 120 55 120 55 120 55 120 55 120 55 120 55 120 55 120 55 120 108 108 167 167 167 167 156 156 167 167 156 156 156 156 156 167 167 156 156 55 123 106 55 124 55 124 55 124 55 124 55 124 56 56 56 56 56 56 56 56 56 56 56 108 108 156 156 108 117 121 121 117 110 110 121 121 121 121 121 51 OUL 540HF 540HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 51OUL 540HF 540HF 520HF 520HF 540IF 540HF 520HF 520HF 540HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF Volt / Origin/

Degrees Percent 3.75 162 0.22 74 0.24 0.18 0.21 0.00 0.32 0.00 0.00 0.25 0.27 0.00 0.00 0.10 0.00 0.15 0.00 0.00 0.56 0.64 0.00 7

12 30 0

25 0

0 23 6

0 0

23 0

9 0

0 22 23 0

3.64 176 0.26 0.78 0.00 0.53 2.66 0.28 0.70 0.00 0.32 0.00 0.29 0.13 0.00 0.30 0.00 0.24 4

7 0

18 173 6

24 0

6 0

24 28 0

21 0

15 0

0 ID 67 0

ID 50 0

0 0

0 0

0 0

0 0

0 0

0 0

0 Location Code TSP - Offset 0

DNT LTS

-0.02 0

INR LTE 20.24 BVC BVC VOL CLP VOL CLP CLP VOL VOL CLP NDF VOL CLP VOL CLP NDF PRA VOL CLP 15S 15S ETL ETL ETL ETL UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS 0

DNT LTE 0

ID 23 0

0 0

0 0

0 0

0 0

0 0

0 0

0 INR TWD CLP VOL DNT BVC VOL CLP BVC CLP VOL VOL CLP PthA CLP VOL 14S 15S 15S 15S LTE 02S 03S 03S 07S 07S 07S 08S 08S 08S 08S 08S 33.77 39.73 0.50 0.50 1.47 1.47

-12.94

-12.94

-12.39

-12.39

-11.77

-10.53

-10.53

-7.21

-7.21

-6.65 4.37 4.54 4.54 9.46 25.80 14.36 15.34 15.34 10.99 30.42

-8.63

-8.63 24.49 24.59 24.59

-16.12

-16.12

-15.18

-14.51

-14.51 Axial Circ Dataset 51i0Bobbi 510 Bobbi 540_Bobbi 540_Bobbi SpecInt 0.09 0.16 SpecInt SpecInt 0.09 0.17 SpecInt 0.15 0.17 R13DCLP+

R13DCLP+

R13DCLP+

0.09 0.17 R13DCLP+

R13DCLP+

R13DCLP+

0.15 0.17 R13DCLP+

SpecInt 0.10 0.11 Spec _Int SpecInt SpecInt SpecInt 0.15 0.17 SpecInt 510 Bobbi 540_Bobbi 540_Bobbi 0.15 0.17 Spec Int Spec Int 540_Bobbi 540 Bobbi R13DCLP+

0.19 0.22 R13DCLP+

540_Bobbi 0.09 0.11 SpecInt Spec lnt Spec tnt 0.09 0.11 Speclnt SpecInt 0.09 0.11 SpecInt SpecInt Page 50 of 325

TR-151, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A Site:

Three Mile Island All Indications, HWith Length and 1 Vidth Outage:

IR14 Tube#

Cal Probe 1 121 1 121 1 121 1 121 1 121 1 121 1 117 1 117 1 117 1 117 1 121 1 121 1 121 1 117 13 117 13 117 13 117 56 14 33 56 14 33 56 16 7

56 22 33 56 22 33 56 23 34 56 23 34 56 30 50 56 30 50 56 32 50 56 32 50 56 48 51 56 48 51 56 54 47 56 55 41 56 56 42 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 Volt / Origin!

Degrees Percent 0.!9 0.00 0.00 0.21 0.00 0.25 0.39 0.39 0.36 0.16 0.00 0.00 0.36 0.36 29 0

0 23 0

17 1

4 15 16 0

0 25 0

520HF 520HF 520HF 520HF 520HF 520HF 540HF 540HF 540HF 540HF 520HF 520HF 520HF 540HF 540HF 540HF 540HF 520HF 520HF 51 OUL 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 51OUL 510UL 51OUL 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

Location Code TSP - Offset VOL 08S CLP 08S CLP 08S VOL 08S CLP 08S VOL 08S INR 08S INR 08S BVC 08S BVC 08S NDF 09S CLP 09S VOL 09S INR 09S INR 04S INR 04S INR 04S 0

VOL ETL 0 CLP ETL 0

INR 03S ID 40 VOL ETL 0

CLP ETL ID 36 VOL ETL 0

CLP ETL 0

VOL ETL 0 CLP ETL 0

ID 20 ID 58 0

CLP ETL VOL ETL VOL ETL CLP ETL

-14.00

-14.00

-12.25

-12.25

-9.18

-9.18 3.06 14.59 36.18 37.39

-2.82

-1.52

-1.52 7.62 14.50 20.69 26.70

-0.01

-0.01 26.64 2.84 2.84 1.70 1.70

-1.12

-1.12 2.29 2.29 1.14 1.14 0

INR LTS

-0.10 0

DNT LTS

-0.06 0

DNT LTS 0.00 Axial Circ Dataset Spec Int 0.05 0.06 SpecInt 0.09 0.11 R13DCLP+

R1 3DCLP+

0.14 0.17 R13DCLP+

R13DCLP+

540_Bobbi 540_Bobbi 540_Bobbi 540_Bobbi R13DCLP+

0.05 0.05 R13DCLP+

R13DCLP+

540_Bobbi 540_Bobbi 540_Bobbi 540_Bobbi KEXP_+Pt 0.16 0.14 KEXP_+Pt 510 Bobbi KEXP-+Pt 0.15 0.19 KEXP_+Pt KEXP-+Pt 0.12 0.14 KEXP +Pt 0.11 0.10 0.17 0.15 KEXP-+Pt KEXP_+Pt KEXP_+Pt KEXP_+Pt KEXP_+Pt 0.12 0.18 KEXP -+Pt 510 Bobbi 510 Bobbi 510 Bobbi Page 51 of 325 0.48 359 0.50 2

1.24 2

0.65 19 0.00 0

2.08 185 0.40 22 0.00 0

0.39 21 0.00 0

0.30 17 0.00 0

0.00 0

0.25 15 0.96 27 0.00 0

1.28 192 14.20 174 17.08 172

TR-151, Revision 0 Appendix II Recordable Indications Component":

TMI-OTSG-A Site:

Three Mile Island

.-4ll Indications. With Length and Width Outage:

1R14 Tube#

Cal Probe 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 57 41 58 42 59 41 60 160 60 42 62 160 62 42 66 42 66 42 67 55 67 55 67 55 67 55 67 41 68 113 68 113 68 160 68 160 68 160 70 56 70 56 71 55 71 55 71 55 71 55 71 69 72 69 73 69 75 69 76 85 77 59 77 59 Volt / Origin!

Degrees Percent 5i0UL 51OUL 51OUL 520HF 51OUL 520HF 51OUL 51OUL 51OUL 520HF 520HF 520HF 520HF 51OUL 540HF 540HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 51OUL 51OUL 51OUL 51OUL 51OUL 520HF 520HF 18.53 16.30 7.23 0.00 0.68 0.00 0.81 0.13 4.43 0.40 0.00 0.00 0.25 3.35 1.06 2.47 0.00 0.36 0.00 0.23 0.00 0.27 0.00 0.69 0.00 4.53 6.93 3.30 2.93 3.87 0.40 0.00 174 172 175 0

94 0

90 107 175 9

0 0

9 175 5

177 0

19 0

18 0

16 0

24 0

164 166 158 157 166 16 0

0 0

0 0

0 0

0 0

0 ID 8

0 0

ID 8

0 ID 17 0

0 0

0 0

0 0

0 ID 47 0

0 0

0 0

0 ID 22 0

Location Code TSP - Offset DNT LTS 0.00 DNT LTS 0.00 DNT LTS

-0.04 NDF LTS 1.56 NQI LTS 1.56 NDF LTS 1.55 NQI LTS 1.55 INR LTE 19.46 DNT LTS

-0.06 VOL ETL 1.43 CLP ETL 1.43 CLP ETL 2.47 VOL ETL 2.47 DNT LTS

-0.21 TWD 15S 36.51 INR LTS

-0.14 CLP UTS

-10.89 VOL UTS

-10.89 NDF UTS

-9.87 VOL ETL

-0.15 CLP ETL

-0.15 VOL ETL

-1.28 CLP ETL

-1.28 VOL ETL 2.09 CLP ETL 2.09 DNT LTS 0.00 DNT LTS 0.00 DNT LTS

-0.98 DNT LTS 0.02 DNT LTS 0.02 VOL ETL 2.15 CLP ETL 2.15 Page 52 of 325 Axial Circ Dataset 510 Bobbi 510 Bobbi 510_Bobbi SpecInt 510 Bobbi SpecInt 510 Bobbi 510 Bobbi 510 Bobbi KEXP_+Pt 0.17 0.15 KEXP_+Pt 0.22 0.15 KEXP_+Pt KEXP_+Pt 510 Bobbi 540 Bobbi 540_Bobbi 0.24 0.27 RI3DCLP+

RI 3DCLP+

R13DCLP+

KEXP_+Pt 0.11 0.10 KEXP_+Pt KEXP_+Pt 0.17 0.15 KEXP_+Pt KEXP_+Pt 0.17 0.19 KEXP_+Pt 510 Bobbi 510 Bobbi 510 Bobbi 510 Bobbi 510_Bobbi KEXP_ Pt 0.16 0.18 KEXP +Pt

TR-151, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A Siite:

Three Mile Island All Indications. With Length and W.Vidth Outage:

1R14 Tube#

Cal 56 77 59 56 77 59 56 77 59 56 77 59 56 77 59 56 77 59 56 77 86 56 83 59 56 83 59 56 83 59 56 83 59 56 91 86 56 91 113 56 93 110 56 93 123 56 93 123 56 116 73 56 116 73 56 117 74 56 117 74 56 121 108 56 121 102 56 121 102 56 121 74 56 121 108 56 123 74 56 123 74 56 124 73 56 124 73 57 55 47 57 56 42 57 57 41 57 58 42 Probe 520HF 520HF 520HF 520HF 520HF 520HF 51OUL 520HF 520HF 520HF 520HF 51OUL 520HF 540HF 520HF 520HF 520HF 520HF 520HF 520HF 540HF 520HF 520HF 520HF 540HF 520HF 520HF 520HF 520HF 51OUL 51OUL 510UL 51OUL Volt / Origin/

Degrees Percent 0.00 0

0.39 15 0.28 16 0.00 0

0.32 24 0.00 0

6.16 167 0.21 0.00 0.00 0.28 15 0

0 18 0.20 85 0.00 0

0.26 15 0.00 0

0.27 13 0.32 20 0.00 0

0.95 31 0.00 30 0.24 0.00 0.44 0.00 0.36 ID ID ID 0

20 22 0

47 0

0 ID 20 0

0 ID 27 0

0 0

0 0

Location Code TSP - Offset CLP ETL VOL ETL VOL ETL CLP ETL VOL ETL CLP ETL DNT LTS VOL ETL CLP ETL CLP ETL VOL ETL 2.60 2.60 3.08 3.08 3.60 3.60 0.00 1.23 1.23 2.28 2.28 NQI 02S 35.18 NDF 03S

-3.82 BVC 15S CLP UTS VOL UTS 0

VOL ETL 0

CLP ETL ID 76 SCI ETL 0

ARC ETL 4

0 22 0

138 0.00 0

1.32 33 0.00 0

0.55 13 2.37 186 8.13 175 9.97 172 6.28 174 0

0 0

0 0

INR CLP VOL RIC INR 15S ETL ETL ETL UTS 0

CLP ETL ID 86 VOL ETL 0

CLP ETL 0

VOL ETL 0

INR LTS 0

DNT LTS 0 DNT LTS 0

DNT LTS 39.29

-7.51

-7.51

-0.30

-0.30 0.68 0.68 25.36

-5.15

-5.15

-4.56 2.84 2.10 2.10

-0.42

-0.42

-0.19 0.00

-0.06 0.00 Axial Circ Dataset 0.11 0.14 KEX~gP +Pt KEXP_+Pt KEXP_+Pt 0.16 0.14 KEXP_+Pt KEXP._+Pt 0.16 0.14 KEXP_+Pt 510 Bobbi KEXP_+Pt 0.16 0.19 KEXP_-+Pt 0.10 0.19 KEXP_+Pt KEXP_+Pt 510 Bobbi SpecInt 540_Bobbi 0.15 0.16 R13DCLP+

R13DCLP+

KEXP_+Pt 0.17 0.14 KEXP_+Pt KEXP_+Pt 0.16 KEXP_+Pt 540_Bobbi 0.12 0.12 KEXP_+Pt KEXP_+Pt KEXP_+Pt 540_Bobbi 0.12 0.18 KEXP_+Pt KEXP_+Pt 0.16 0.19 KEXP_+Pt KEXP_+Pt 510 Bobbi 510_Bobbi 510 Bobbi 510 Bobbi Page 53 of 325

TR-151, Revision 0 Appendix 11 Recordable Indications Component:

TMI-OTSG-A Site:

Three Mile Island All hIdications. lJith Length and W,7idth Outage:

1R14 Volt / Origin/

Location Tube#

Cal Probe Degrees Percent Code TSP - Offset Axial Circ Dataset 57 59 55 520HF 1.17 28 ID 63 VOL ETL 1.00 KEXP_-+Pt 57 59 55 520HF 0.00 0

0 CLP ETL 1.00 0.22 0.25 KEXP +Pt 57 59 55 520HF 0.22 16 ID 22 VOL ETL 2.14 KEXP-+Pt 57 59 55 520HF 0.00 0

0 CLP ETL 2.14 0.22 0.15 KEXP-+Pt 57 59 55 520HF 0.47 18 ID 27 VOL ETL 5.36 KEXP_+Pt 57 59 55 520HF 0.00 0

0 CLP ETL 5.36 0.15 0.15 KEXP_+Pt 57 59 41 51OUL 8.67 175 0

DNT LTS

-0.34 510_Bobbi 57 60 56 520HF 0.00 0

0 CLP ETL

-0.38 0.17 0.20 KEXP_+Pt 57 60 56 520HF 1.08 23 0

VOL ETL

-0.38 KEXP_+Pt 57 60 42 51OUL 6.33 173 0 DNT LTS 0.00 510_Bobbi 57 63 113 540HF 0.77 9

ID 30 TWD 15S 36.95 540_Bobbi 57 63 160 520HF 0.31 14 0 VOL UTS

-14.18 SpecInt 57 63 160 520HF 0.00 0

0 CLP UTS

-14.18 0.15 0.16 SpecInt 57 63 160 520HF 0.00 0

0 CLP UTS

-10.30 0.19 0.22 SpecInt 57 63 160 520HF 0.70 25 0

VOL UTS

-10.30 SpecInt 57 65 113 540HF 0.47 6

ID 20 TWD 15S 37.63 540_Bobbi 57 65 113 540HF 0.21 9

0 BVC 15S 42.31 540 Bobbi 57 65 113 540HF 0.27 10 0 BVC 15S 43.74 540 Bobbi 57 65 133 520HF 0.68 17 0 VOL UTS

-8.87 R13DCLP+

57 65 133 520HF 0.00 0

0 CLP UTS

-8.87 0.15 0.15 R13DCLP+

57 65 160 520HF 0.00 0

0 RIC UTS

-8.74 R13DCLP+

57 65 160 520HF 0.27 19 0

VOL UTS

-6.49 SpecInt 57 65 160 520HF 0.00 0

0 CLP UTS

-6.49 0.14 0.16 SpecInt 57 65 160 520HF 0.00 0

0 CLP UTS

-4.36 0.14 0.16 Spec Int 57 65 160 520HF 0.22 17 0

VOL UTS

-4.36 SpecInt 57 65 160 520HF 0.00 0

0 CLP UTS

-2.85 0.14 0.16 SpecInt 57 65 160 520HF 0.34 21 0

VOL UTS

-2.85 SpecInt 57 66 42 51OUL 3.40 177 0

DNT LTS 0.00 510_Bobbi 57 67 41 51OUL 0.18 85 0

NQI 05S 29.01 510_Bobbi 57 67 160 520HF 0.00 0

0 NDF 06S

-7.99 SpecInt 57 68 160 520HF 0.00 0

0 NDF 15S 12.94 SpecInt 57 68 41 51OUL 0.17 83 0

NQI 15S 12.94 510 Bobbi 57 70 55 520HF 0.33 19 ID 19 VOL ETL 0.09 KEXP_+Pt 57 70 55 520HF 0.00 0

0 CLP ETL 0.09 0.19 0.17 KEXP_+Pt 57 70 55 520HF 0.00 0

0 CLP ETL 0.67 0.19 0.17 KEXP_-+Pt 57 70 55 520HF 0.76 27 ID 58 VOL ETL 0.67 KEXP +Pt Page 54 of 325

TR-151, Revision 0 Appendix II Recordabl, Indic.ations Component:

TMI-OTSG-A Site:

Three Mile Island All hIdications, With Lenglh and J4'idth Outage:

1R14 Volt / Origint Location Tube#

Cal Probe Degrees Percent Code TSP - Offset Axial Circ Dataset 57 71 56 520HF 0.50 26 0

VOL ETL

-0.02 KEXP_+Pt 57 71 56 520HF 0.00 0

0 CLP ETL

-0.02 0.12 0.18 KEXP_+Pt 57 71 56 520HF 0.42 16 ID 22 VOL ETL 1.69 KEXP_+Pt 57 71 56 520HF 0.00 90 0

CLP ETL 1.69 0.12 0.09 KEXP_-+Pt 57 71 56 520HF 0.31 18 ID 27 VOL ETL 2.42 KEXP_+Pt 57 71 56 520HF 0.00 90 0

CLP ETL 2.42 0.12 0.14 KEXP_+Pt 57 71 56 520HF 0.20 12 ID 13 VOL ETL 3.24 KEXP_-+Pt 57 71 56 520HF 0.00 0

0 CLP ETL 3.24 0.12 0.09 KEXP_+Pt 57 71 56 520HF 0.00 0

0 CLP ETL 4.41 0.12 0.14 KEXP_+Pt 57 71 56 520HF 1.17 26 ID 54 VOL ETL 4.41 KEXP_+Pt 57 71 56 520HF 0.00 90 0

CLP ETL 5.30 0.24 0.18 KEXP_+Pt 57 71 56 520HF 0.43 18 ID 27 VOL ETL 5.30 KEXP_+Pt 57 71 69 51OUL 6.58 165 0

DNT LTS 0.00 510_Bobbi 57 72 69 51OUL 12.31 169 0 DNT LTS 0.00 510 Bobbi 57 73 69 51OUL 7.89 167 0

DNT LTS 0.00 510_Bobbi 57 74 69 51OUL 7.30 165 0 DNT LTS 0.00 510_Bobbi 57 75 69 51OUL 0.25 83 0 NQI 04S 0.71 510_Bobbi 57 75 160 520HF 0.53 109 OD 8

TWD 04S 0.78 SpecInt 57 77 86 51OUL 7.74 167 0

DNT LTS 0.00 510_Bobbi 57 78 113 520HF 0.00 0

0 NDF 02S 4.17 SpecInt 57 78 85 51OUL 1.48 81 0

ADI 02S 4.17 510_Bobbi 57 78 85 51OUL 5.08 167 0 DNT LTS

-0.04 510 Bobbi 57 82 123 520HF 0.21 17 0

VOL 15S 5.28 R13DCLP+

57 82 123 520HF 0.00 0

0 CLP 15S 5.28 0.19 0.17 R13DCLP+

57 92 110 540HF 0.22 7

0 BVC 15S 40.44 540_Bobbi 57 92 113 520HF 0.44 21 0

VOL UTS

-5.87 Spec Int 57 92 113 520HF 0.00 0

0 CLP UTS

-5.87 0.09 0.17 Spec lnt 57 94 79 520HF 0.43 22 0

VOL ETL

-1.02 R13DCLP+

57 94 79 520HF 0.00 0

0 CLP ETL

-1.02 0.18 0.14 R13DCLP+

57 94 79 520HF 0.48 25 ID 27 VOL ETL 3.31 R]3DCLP+

57 94 79 520HF 0.00 0

0 CLP ETL 3.31 0.12 0.14 R13DCLP+

57 94 79 520HF 0.38 14 ID 22 VOL ETL 3.71 R13DCLP+

57 94 79 520HF 0.00 0

0 CLP ETL 3.71 0.18 0.14 R13DCLP+

57 115 73 520HF 0.00 0

0 CLP ETL

-0.42 0.16 0.14 KEXP_+Pt Page 55 of 325

TR-151, Revision 0 Appendix II Recordable indications Component:

TMI-OTSG-A Site Three Mile Island All Indications, With Length and WVidth Outage:

1R14 Tube#

Cal Probe 57 115 73 57 118 104 57 126 104 57 126 104 58 13 15 58 25 117 58 25 110 58 25 110 58 50 50 58 50 50 58 54 114 58 54 48 58 57 4

58 58 3

58 59 4

58 60 3

58 61 4

58 62 3

58 63 4

58 66 3

58 72 3

58 73 4

58 74 3

58 75 4

58 78 81 58 79 59 58 79 59 520HF 51 OUL 51 OUL 51 OUL 51OUL 540HF 520HF 520HF 520HF 520HF 520HF 51 OUL 51OUL 51OUL 51 OUL 51 OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51 OUL 51 OUL 51 OUL 510UL 520HF 520HF Volt/ Origin' Degrees Percent 0.33 2.06 3.90 4.57 2.67 0.41 0.35 0.00 0.00 0.49 0.00 1.21 5.90 4.03 2.35 3.86 4.39 4.60 2.90 3.40 5.87 11.45 10.15 9.52 3.77 0.00 0.23 6

176 174 174 184 5

18 0

0 27 0

88 174 174 186 178 176 174 176 162 166 165 169 162 155 0

9 0

0 0

0 0

ID 17 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

Code VOL INR DNT DNT DNT TWD VOL CLP CLP VOL NDF ADI DNT DNT INR DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT CLP VOL Location TSP - Offset ETL

-0.42 LTE 16.32 LTE 8.61 LTE 10.77 12S 12.89 15S 43.55 UTS

-2.89 UTS

-2.89 ETL

-0.50 ETL

-0.50 01S

-4.16 LTS 41.84 LTS

-0.45 LTS

-0.09 LTS

-0.19 LTS

-0.25 LTS

-0.31 LTS

-0.11 LTS

-0.25 LTS

-0.21 LTS 0.15 LTS 0.09 LTS 0.09 LTS 0.06 LTS 0.04 ETL

-0.16 ETL

-0.16 Axial Circ Dataset KEXP_+Pt 510_Bobbi 510 Bobbi 510 Bobbi 510 Bobbi 540_Bobbi SpecInt 0.09 0.17 Spec Int 0.17 0.17 KEXP_+Pt KEXP_+Pt SpecInt 510_Bobbi 510 Bobbi 510 Bobbi 510_Bobbi 510 Bobbi 510 Bobbi 510 Bobbi 510 Bobbi 510 Bobbi 510 Bobbi 510 Bobbi 510 Bobbi 510 Bobbi 510 Bobbi 0.16 0.19 KEXP +Pt KEXP +Pt Page 56 of 325

TR-151, Revision 0 Appendix II Recordable

'Indictironc, C'omponent:

TMI-OTSG-A Site:

Three Mile Island

.11 Indications., With LeIglh and Width Outage:

1R14 Volt! Origin/

Degrees Percent 3.97 167 0.28 31 0.23 8

0.00 0

0.33 12 0.44 20 0.00 0

2.67 186 1.09 81 0.00 0

Cal Tube#

58 79 81 58 80 81 58 89 79 58 89 79 Probe 51OUL 51OUL 520HF 520HF 540HF 520HF 520HF 51OUL 51OUL 520HF 520HF 520HF 520HF 520HF 540HF 51OUL 540HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 540HF 520HF 520HF 5201-IF 5201-IF 51OUL 520HF 520HF Code 0

DNT Location TSP - Offset LTS 0.00 0

INR 13S 0 VOL ETL 0 CLP ETL 0

0 0

BVC 15S VOL UTS CLP UTS 12.05

-2.65

-2.65 44.00

-2.27

-2.27 0

DNT 1OS 25.51 0

ADI I1S 0 NDF 12S VOL CLP VOL CLP BVC ETL ETL ETL ETL UTS 0.24 85 OD 6

TWD 08S 0.28 0.00 0.16 0.54 0.00 0.00 0.37 0.00 0.00 0.54 0.26 0.20 0.00 0.24 0.00 15 0

8 26 0

0 17 0

0 23 16 8

0 13 0

3.21 173 0.16 18 0.00 0

0 0

0 0

0 0

0 0

0 0

0 ID 14 0

0 0

BVC CLP VOL VOL CLP RIC VOL CLP CLP VOL BVC VOL CLP VOL CLP 15S ETL ETL ETL ETL UTS UTS UTS UTS UTS 15S ETL ETL UTS UTS 28.11

-9.89

-2.81

-2.81 0.44 0.44 3.62

-0.74 40.55

-5.42

-5.42

-4.36

-4.36

-6.19

-6.02

-6.02 3.25 3.25 39.92 1.01 1.01

-6.76

-6.76 0

DNT LTE 10.73 0 VOL ETL 0 CLP ETL

-2.06

-2.06 Axial Circ Dataset 510 Bobbi 510 Bobbi R13DCLP+

0.18 0.14 R13DCLP+

540_Bobbi R13DCLP+

0.14 0.17 R13DCLP+

510 Bobbi 510 Bobbi SpecInt R13DCLP+

0.16 0.15 R13DCLP+

R13DCLP+

0.11 0.15 R13DCLP+

540 Bobbi 510 Bobbi 540_Bobbi 0.12 0.09 R13DCLP+

R13DCLP+

RI3DCLP+

0.12 0.18 R13DCLP+

R13DCLP+

R13DCLP+

0.14 0.17 R13DCLP+

0.14 0.17 R13DCLP+

RI 3DCLP+

540_Bobbi R13DCLP+

0.14 0.11 R13DCLP+

R13DCLP+

0.09 0.16 R13DCLP+

510 Bobbi R13DCLP+

0.11 0.14 R13DCLP+

Page 57 of 325 9

0 18 0

11 0

0 ID 18 0

0 58 94 58 94 58 94 110 123 123 58 97 85 58 99 85 58 99 113 58 105 58 105 58 105 58 105 58 105 133 133 133 133 110 58 113 103 0.24 0.00 0.39 0.00 0.30 58 117 58 117 58 117 58 117 58 117 58 117 58 117 58 117 58 117 58 117 58 120 58 120 58 120 58 120 58 120 108 79 79 79 79 79 167 167 167 167 108 167 167 167 167 58 125 103 59 22 79 59 22 79

TR-151, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A Site:

Three Mile Island

.41/ Indications, lWith Length and Width Outage:

1R14 Tube#

Cal 59 22 79 59 22 79 59 55 3

59 55 25 59 58 4

59 59 3

59 60 4

59 70 4

59 71 3

59 72 138 59 72 138 59 72 25 59 72 25 59 72 3

59 72 3

59 73 3

59 77 12 59 83 113 59 83 81 59 119 103 59 119 156 60 3

20 60 8 33 60 8 33 60 14 33 60 14 33 60 19 33 60 19 33 60 19 33 60 19 33 Probe 520HF 520HF 51OUL 520HF 51OUL 51OUL 51OUL 51OUL 51OUL 520PI 520PI 520HF 520HF 51OUL 51OUL 51OUL 460PP 520HF 51OUL 51OUL 520HF 51OUL 520HF 520HF 520HF 520HF 520HIF 520HF 520HF 520HF J'olt/ Origin/

Degrees Percent Location Code TSP - Offset 0.39 24 ID 47 VOL ETL 0.00 0

0 CLP ETL 0.95 92 0 NQI LTS 0.00 0

0 NDF LTS 2.97 176 0

DNT LTS 3.73 174 0 DNT LTS 4.32 173 0 DNT LTS 5.70 160 0 DNT LTS 13.57 169 0

DNT LTS 0.16 64 OD 69 SVI 07S 0.00 0

0 CLP 07S 0.00 0

0 CLP 07S 0.13 73 OD 56 SVI 07S 0.22 74 0

NQI 07S 18.82 170 0

DNT LTS 8.91 165 0 DNT LTS 0.00 0

0 OBS UTE 0.00 0

0 NDF LTS 8.10 183 0

IDC LTS 0.26 97 0

NQI LTE 0.00 0

0 NDF LTS 0.19 82 0

INR 15S 0.33 19 ID 32 VOL ETL 0.00 0

0 CLP ETL 0.65 9

ID 11 VOL ETL 0.00 0

0 CLP ETL 0.38 21 ID 37 VOL ETL 0.00 0

0 CLP ETL 0.00 0

0 CLP ETL 0.51 23 ID 43 VOL ETL 3.07 3.07 1.11 1.11

-0.51

-0.09

-0.13 0.00 0.31 13.45 13.45 13.67 13.67 13.70 0.11

-0.06 0.00 4.49 4.49 20.77

-3.23

-0.43 0.57 0.57 1.18 1.18 0.64 0.64 4.04 4.04 Axial Circ Dataset R13DCLP+

0.11 0.14 R13DCLP+

510 Bobbi SpecInt 510 Bobbi 510 Bobbi 510 Bobbi 510_Bobbi 510 Bobbi Postln_+Pt 0.13 0.12 Postln_+Pt 0.10 0.10 SpecInt SpecInt 510_Bobbi 510_Bobbi 510 Bobbi PlugMRP 43.96 SpecInt 43.96 510 Bobbi 510 Bobbi SpecInt 510 Bobbi KEXP_+Pt 0.10 0.15 KEXP +Pt KEXP-+Pt 0.10 0.14 KEXP_+Pt KEXP_+Pt 0.16 0.14 KEXP_+Pt 0.10 0.14 KEXP_-Pt KEXP +Pt Page 58 of 325

TR-151, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A Site:

Three Mile Island A./ Idications, S

1hit Length and JVidth Outage:

1R14 Tube#

Cal Probe Volt / Origin/

Degrees Percent Location Code TSP - Offset 60 30 51 60 30 51 60 31 119 60 53 51 60 53 51 60 57 5

60 57 125 60 59 21 60 59 21 60 59 21 60 59 21 60 59 21 60 59 21 60 60 6

60 61 5

60 62 6

60 63 21 60 63 129 60 63 116 60 63 21 60 65 7

60 65 25 60 65 25 60 66 6

60 71 4

60 71 125 60 72 20 60 72 20 60 73 4

60 74 3

60 75 4

520HF 520HF 51OUL 520HF 520HF 51OUL 520HF 520HF 520HF 520HF 520HF 520HF 520HF 51OUL 51OUL 51OUL 520HF 520HF 520HF 520HF 540HF 520HF 520HF 51 OUL 51OUL 520HF 520HF 520HF 51OUL 51OUL 51 OUL 0.30 18 ID 27 VOL ETL 0.00 0

0 CLP ETL 0.30 97 0

INR LTE 0.00 0

0 CLP ETL 0.58 28 0

VOL ETL 0.87 84 0

NQI LTS 0.00 0

0 NDF LTS 0.62 27 ID 58 VOL ETL 0.00 0

0 CLP ETL 0.31 15 ID 20 VOL ETL 0.00 0

0 CLP ETL 0.00 0

0 CLP ETL 0.42 21 ID 36 VOL ETL 2.50 177 0

DNT LTS 2.90 172 0

DNT LTS 2.52 175 0

DNT LTS 0.00 0

0 CLP ETL 0.51 17 0

PID ETL 0.00 0

0 RPD ETL 0.39 26 ID 54 VOL ETL 0.45 6

ID 20 TWD 15S 0.00 0

0 CLP 15S 0.53 21 0

VOL 15S 2.78 177 0

DNT LTS 0.23 88 0

NQI LTS 0.00 0

0 NDF LTS 0.34 25 ID 51 VOL ETL 0.00 0

0 CLP ETL 6.07 158 0

DNT LTS 12.49 169 0

DNT LTS 18.91 169 0

DNT LTS Page 59 of 325 Axial Circ Dataset 1.37 1.37 4.97

-0.12

-0.12 0.66 0.66 0.71 0.71 1.99 1.99 3.72 3.72 0.00 0.09 0.00 0.29 0.29 0.29 0.29 37.28 37.77 37.77 0.04 1.72 1.72 0.56 0.56 0.00 0.00 0.11 KEXP_+Pt 0.11 0.14 KEXP_+Pt 510_Bobbi 0.12 0.19 KEXP_+Pt KEXP_+Pt 510_Bobbi LTS_+Pt KEXP_+Pt 0.11 0.17 KEXP_+Pt KEXP_+Pt 0.11 0.17 KEXP_+Pt 0.11 0.22 KEXP_+Pt KEXP_+Pt 510_Bobbi 510 Bobbi 510 Bobbi 0.16 0.11 KEXP_+Pt KEXP_+Pt KEXP_+Pt KEXP_+Pt 540_Bobbi 0.10 0.19 SpecInt SpecInt 5 10 Bobbi 510 Bobbi LTS_+Pt KEXP_+Pt 0.10 0.11 KEXP_+Pt 510_Bobbi 510 Bobbi 510 Bobbi

TR-151, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A Site:

Three Mile Island

.411 hIdications. Jf'ith Length and ITfidth Outage:

1R14 Volt / Origin!

Location Tube#

Cal Probe Degrees Percent Code TSP - Offset Axial Circ Dataset 60 76 3

510UL 8.85 164 0 DNT LTS 0.20 510_Bobbi 60 78 59 520HF 0.00 0

0 CLP ETL 2.68 0.15 0.19 KEXP_+Pt 60 78 59 520HF 0.42 13 ID 15 VOL ETL 2.68 KEXP_+Pt 60 79 131 540HF 0.27 13 0

BVC 15S 31.08 540_Bobbi 60 79 123 520HF 0.00 0

0 CLP UTS

-15.57 0.14 0.17 R13DCLP+

60 79 123 520HF 0.11 15 0

VOL UTS

-15.57 R13DCLP+

60 80 59 520HF 0.00 0

0 CLP ETL 2.05 0.16 0.19 KEXP_+Pt 60 80 59 520HF 0.47 20 ID 33 VOL ETL 2.05 KEXP_+Pt 60 81 81 51OUL 8.83 173 0

DNT 12S 6.48 510_Bobbi 60 86 81 51OUL 0.70 8

ID 27 TWD 14S 9.64 510_Bobbi 60 86 110 540HF 0.98 1

0 INR 14S 9.64 540_BobEx 60 121 103 51OUL 3.76 161 0 DNT 13S 31.01 510_Bobbi 60 121 156 520HF 0.00 0

0 NDF 14S

-4.99 SpecInt 60 121 73 520HF 0.00 0

0 CLP ETL

-1.36 0.17 0.14 KEXP_+Pt 60 121 73 520HF 0.24 14 0

VOL ETL

-1.36 KEXP_+Pt 60 121 73 520HF 0.50 20 ID 33 VOL ETL 0.48 KEXP_+Pt 60 121 73 520HF 0.00 0

0 CLP ETL 0.48 0.10 0.14 KEXP_+Pt 60 121 73 520HF 0.00 0

0 CLP ETL 2.46 0.16 0.19 KEXP_+Pt 60 121 73 520HF 0.96 21 ID 36 VOL ETL 2.46 KEXP_+Pt 60 123 73 520HF 0.28 19 0

VOL ETL

-4.17 KEXP_+Pt 60 123 73 520HF 0.00 0

0 CLP ETL

-4.17 0.16 0.14 KEXP_+Pt 60 123 73 520HF 0.00 0

0 CLP ETL

-2.97 0.10 0.14 KEXP_+Pt 60 123 73 520HF 0.50 25 0

VOL ETL

-2.97 KEXP_+Pt 60 123 73 520HF 0.48 22 0

VOL ETL

-0.65 KEXP_+Pt 60 123 73 520HF 0.00 0

0 CLP ETL

-0.65 0.16 0.19 KEXP_+Pt 60 123 73 520HF 0.34 3

1 VOL ETL 0.89 KEXP_+Pt 60 123 73 520HF 0.00 0

0 CLP ETL 0.89 0.10 0.14 KEXP_+Pt 60 123 73 520HF 0.00 0

0 CLP ETL 1.14 0.10 0.14 KEXP_+Pt 60 123 73 520HF 0.28 8

ID 6

VOL ETL 1.14 KEXP_+Pt 60 123 73 520HF 0.00 0

0 CLP ETL 1.80 0.16 0.19 KEXP_+Pt 60 123 73 520HF 0.83 25 ID 51 VOL ETL 1.80 KEXP_+Pt 60 123 73 520HF 0.10 25 ID 51 VOL ETL 2.13 KEXP +Pt 60 123 73 520HF 0.00 0

0 CLP ETL 2.13 0.10 0.09 KEXP_+Pt 60 123 73 520HF 0.36 12 ID 13 VOL ETL 3.82 KEXP_+Pt 60 123 73 520HF 0.00 0

0 CLP ETL 3.82 0.10 0.14 KEXP_+Pt Page 60 of 325

TR-151, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A Site:

Three Mile Island All lndication7s, With Lengd? and WVidth Ontage:

1R14 Location TSP - Offset 15S 25.48 15S 26.02 UTS

-20.87 UTS

-20.87 UTS

-20.59 UTS

-20.59 UTS

-19.92 UTS

-19.92 39.92

-0.41

-0.41

-6.81

-6.81 Axial Circ Dataset 540 Bobbi 540 Bobbi 0.14 0.22 RI3DCLP+

RI3DCLP+

0.14 0.16 RI3DCLP+

R13DCLP+

R13DCLP+

0.23 0.16 R13DCLP+

540_Bobbi 0.10 0.10 KEXP_+Pt KEXP_+Pt 0.14 0.17 R13DCLP+

R13DCLP+

Tube#

60 125 108 60 125 108 60 125 167 60 125 167 60 125 167 60 125 167 60 125 167 60 125 167 60 128 108 60 128 73 60 128 73 60 128 167 60 128 167 61 8

20 61 9

20 61 9

20 61 18 33 61 18 33 61 50 119 61 50 114 61 53 119 61 53 114 61 61 20 61 61 20 61 64 5

61 72 5

61 73 6

61 74 5

61 75 81 Cal Probe 540HF 540HF 520HF 520HF 520HF 520HF 520HF 520HF 540HF 520HF 520HF 520HF 520HF 51 OUL 51OUL 51 OUL 520HF 520HF 51OUL 520HF 51OUL 520HF 520HF 520HF 51OUL 51OUL 51OUL 51OUL 51OUL 540HF 520HF 520HF 510_Bobbi 510_Bobbi 510_Bobbi 68.00 KEXP_+Pt 0.11 0.19 KEXP_+Pt 510 Bobbi SpecInt 510 Bobbi SpecInt 0.18 KEXP_+Pt KEXP_+Pt 510_Bobbi 510 Bobbi 510_Bobbi 510_Bobbi 510 Bobbi 540_Bobbi SpecInt 0.14 0.17 Spec mt Page 61 of 325 11.01 19.82 0.57 0.57 35.89

-3.11 35.66

-2.34 3.01 3.01

-0.04 0.00 0.00 0.15 0.00 37.49

-8.98

-8.98 Volt /

Degrees 0.46 7

0.68 6

0.00 0

0.73 24 0.00 0

0.72 24 0.29 16 0.00 0

Origin!

Percent ID 23 ID 20 0

0 0

0 0

0 Code TWD TWD CLP VOL CLP VOL VOL CLP BVC CLP VOL CLP VOL 0.34 0.00 0.32 0.00 0.38 5

0 19 0

15 0

0 0

0 0

15S ETL ETL UTS UTS 0

DNT LTE 11.17 0

0 0

ARC ETL 91 SCI ETL 0

DNT LTS 0 DNT LTS 0

DNT LTS 0

DNT LTS 0

DNT LTS 23 TWD 15S 0

VOL UTS 0

CLP UTS ID 21 0

DNT LTE INR LTE VOL ETL CLP ETL NQI 02S NDF 03S DNT 01S NDF 02S 0

0 0

0 5.92 173 6.11 173 4.68 2

0.50 14 0.00 0

0.22 82 0.00 0

2.62 174 0.00 0

0.00 34 1.65 34 2.87 169 3.21 165 8.94 163 11.31 168 4.58 162 0.40 7

0.25 9

0.00 0

ID ID 61 61 61 79 110 79 113 79 113

TR-151, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A Site.

Three Mile Island All indications, WT'ith Length and W4idth Outage:

1R14 Volt / Origin!

Degrees Percent 0.51 232 Tube#

61 82 79 61 90 79 61 90 79 61 103 96 61 103 113 61 121 103 61 121 156 61 124 73 62 5

8 62 7

21 62 9

21 62 20 22 62 28 33 62 28 33 62 30 119 62 30 169 62 30 51 62 30 51 62 44 51 62 44 51 62 44 51 62 44 51 62 44 51 62 44 51 62 44 51 62 44 51 62 46 119 62 46 114 62 47 50 62 47 50 62 47 50 62 47 50 Cal Location Code TSP - Offset 0

INR ETL Probe 520HF 520HF 520HF 51OUL 520HF 51OUL 520HF 520HF 460PP 51OUL 51OUL 51OUL 520HF 520HF 51 OUL 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 51OUL 520HF 520HF 520HF 520HF 520HF 0.32 11 ID 11 VOL ETL 0.24 0.00 1.07 0.00 0.23 0.00 0.36 0.58 5.74 5.96 3.64 0.00 0.36 3.26 0.00 0.76 0.00 0.74 0.00 0.00 0.31 0.93 0.00 0.00 0.58 0.22 0.83 0.32 0.00 0.00 21 0

89 0

110 0

38 121 177 177 174 0

9 173 0

33 0

25 0

0 16 28 0

0 16 60 109 9

0 0

Page 62 of 325 0

VOL ETL 0

CLP ETL 0 ADI 07S 0 NDF 07S 0 NQI 10S 0 NDF 10S 0 INR ETL 0

AOD UTE 0 DNT LTE 0

DNT LTE 0

DNT 06S 0

CLP ETL 0

VOL ETL 0

DNT 01S 0 NDF 01S ID 86 VOL ETL 0

CLP ETL ID 51 VOL ETL 0

CLP ETL 0

CLP ETL ID 22 VOL ETL ID 63 VOL ETL 0

CLP ETL 0

CLP ETL ID 22 VOL ETL 0

NQI 06S OD 12 TWD 06S ID 8 VOL ETL 0

CLP ETL 0

CLP ETL

-1.06

-2.68

-2.68 3.69 3.69 10.41 10.41

-0.29

-0.56 11.46 11.24 28.48

-1.52

-1.52 14.52 14.52 0.01 0.01 3.09 3.09 3.85 3.85 4.34 4.34 5.06 5.06 0.67 0.84 1.45 1.45 2.04 2.04 Axial Circ Dataset R13DCLP+

R13DCLP+

0.18 0.14 R13DCLP+

510 Bobbi SpecInt 510_Bobbi Spec Int KEXP_+Pt PlugMRP 510 Bobbi 510 Bobbi 510 Bobbi 0.16 0.19 KEXP_+Pt KEXP_+Pt 510 Bobbi SpecInt KEXP_+Pt 0.11 0.19 KEXP_+Pt KEXP_+Pt 0.12 0.14 KEXP_+Pt 0.12 0.14 KEXP_+Pt KEXP_+Pt KEXP_+Pt 0.12 0.14 KEXP_+Pt 0.12 0.14 KEXP_+Pt KEXP_+Pt 510_Bobbi Spec mnt KEXP_ Pt 0.20 0.17 KEXP_+Pt 0.20 0.17 KEXP +Pt KEXP +Pt

TR-151. Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A Site:

Three Mile Island All IlndiCationS, W 'ith Length ancid Width Outage:

IR14 Tube#

Cal Probe 62 52 51 62 52 51 62 53 50 62 53 50 62 53 50 62 53 50 62 53 50 62 53 50 62 53 50 62 53 130 62 53 50 62 53 50 62 53 50 62 53 50 62 53 50 62 53 50 62 53 50 62 53 50 62 53 50 62 53 50 62 53 50 62 53 130 62 53 130 62 59 21 62 59 21 62 59 21 62 59 21 62 64 21 62 64 21 62 64 21 62 64 21 62 65 5

62 69 21 62 69 21 62 69 21 62 69 21 62 69 21 62 69 21 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 510UL 520HF 520HF 520HF 520HF 520HF 520HF Volt / Origin/

Degrees Percent 0.49 23 0.00 0

0.13 16 0.00 0

0.16 29 0.00 0

0.00 0

0.00 0

0.36 26 0.78 29 0.00 0

0.85 21 0.00 0

0.48 16 0.00 0

0.48 21 0.00 0

0.00 0

0.18 23 0.00 0

0.40 21 1.37 31 0.00 0

0.27 17 0.00 0

0.65 25 0.00 0

0.00 0

0.44 26 0.24 19 0.00 0

3.66 174 0.50 0.00 0.14 0.00 0.14 0.00 25 0

18 0

20 0

ID Location Code TSP - Offset 43 VOL ETL 0

CLP ETL 0 VOL ETL 0

CLP ETL 0 VOL ETL 0

CLP ETL 0

RPP ETL 0

CLP ETL ID 54 VOL ETL 0

PID ETL 0

CLP ETL ID 36 VOL ETL 0

RPD ETL ID 22 VOL ETL 0 CLP ETL ID 36 VOL ETL 0

CLP ETL 0

CLP ETL ID 43 VOL ETL 0 CLP ETL ID 36 VOL ETL ID 76 VOL ETL 0

CLP ETL ID 25 VOL ETL 0

CLP ETL ID 51 VOL ETL 0

CLP ETL 0

CLP ETL 0

VOL ETL ID 30 VOL ETL 0

CLP ETL 0

DNT LTS ID 51 VOL ETL 0

CLP ETL ID 27 VOL ETL 0

CLP ETL ID 33 VOL ETL 0

CLP ETL 0.60 0.60

-2.82

-2.82

-2.69

-2.69

-1.00 0.03 0.03 1.22 1.22 1.22 1.22 2.03 2.03 2.79 2.79 3.71 3.71 4.51 4.51 6.64 6.64 0.77 0.77 0.85 0.85

-0.10

-0.10 3.78 3.78

-0.17 0.98 0.98 1.65 1.65 1.68 1.68 Axial Circ Dataset KEXP_+Pt 0.11 0.14 KEXP_+Pt 7.40 KEXP_+Pt 0.11 0.10 KEXP_+Pt KEXP_+Pt 0.17 0.10 KEXP_+Pt SpecInt 0.17 0.15 SpecInt SpecInt KEXP_+Pt 0.11 0.15 SpecInt SpecInt SpecInt SpecInt 0.11 0.15 SpecInt SpecInt 0.17 0.10 SpecInt 0.11 0.10 SpecInt Spec Int 0.11 0.15 SpecInt SpecInt KEXP_+Pt 0.10 0.17 KEXP_+Pt KEXP_+Pt 0.12 0.15 KEXP_+Pt KEXP_+Pt 0.12 0.15 KEXP_+Pt 0.16 0.11 KEXP_+Pt KEXP_+Pt KEXP_+Pt 0.12 0.10 KEXP_+Pt 510 Bobbi KEXP_+Pt 0.12 0.15 KEXP_+Pt KEXP_+Pt 0.12 0.15 KEXP +Pt KEXP_ Pt 0.12 0.10 KEXP -+-Pt Page 63 of 325

TR-151, Revision 0 Appendix II Recordable Indications Component":

TMI-OTSG-A Site:

Three Mile Island All Inclications. With Length and Width Outage:

1R14 Tube#

Cal Probe 62 69 21 62 69 21 62 75 21 62 75 21 62 75 21 62 75 21 62 75 21 62 75 21 62 75 5

62 76 5

62 79 59 62 79 59 62 81 96 62 82 95 62 84 95 62 86 12 62 114 108 62 123 73 62 123 73 63 1

16 63 2 128 63 8 21 63 9

21 63 17 79 63 17 79 63 17 79 63 17 79 63 19 110 63 19 21 63 39 77 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 51OUL 510UL 520HF 520HF 51OUL 51OUL 51OUL 460PP 540HF 520HF 520HF 460PP 51OUL 51OUL 51OUL 520HF 520HF 520HF 520HF 520HF 51OUL 520HF Volt / Origin!

Degrees Percent Location Code TSP - Offset 0.22 20 ID 33 VOL ETL 0.00 0

0 CLP ETL 0.00 0

0 CLP ETL 0.22 17 ID 25 VOL ETL 0.00 0

0 CLP ETL 0.40 19 ID 30 VOL ETL 0.41 21 ID 36 VOL ETL 0.00 0

0 CLP ETL 4.02 165 0 DNT LTS 2.99 165 0

DNT LTS 0.00 0

0 CLP ETL 0.12 30 0

VOL ETL 2.29 182 0

INR LTS 2.34 178 0

INR LTS 0.76 44 0

INR LTS 0.00 0

0 OBS UTE 1.32 2

0 INR 02S 0.36 24 ID 47 VOL ETL 0.00 0

0 CLP ETL 0.00 0

0 OBS UTE 0.64 112 OD 16 TWD 11S 6.63 177 0 DNT LTE 5.89 176 0 DNT LTE 0.28 14 0 VOL ETL 0.00 0

0 CLP ETL 0.31 15 ID 20 VOL ETL 0.00 0

0 CLP ETL 0.00 0

0 NDF 08S 0.16 87 0 NQI 08S 0.40 21 0

VOL ETL 4.01 4.01 0.91 0.91 1.91 1.91 4.14 4.14 0.00

-0.11

-0.05

-0.05 0.00 0.00 2.04 0.00 14.97 0.85 0.85 0.00

-0.28 11.24 11.17

-1.24

-1.24 2.01 2.01 17.29 17.29

-0.37 Axial Circ Dataset KEXP +Pt 0.12 0.10 KEXP_+Pt 0.06 0.10 KEXP_+Pt KEXP_+Pt 0.12 0.15 KEXP_+Pt KEXP_+Pt KEXP_+Pt 0.12 0.20 KEXP_+Pt 510_Bobbi 510 Bobbi 0.16 0.13 KEXP_+Pt KEXP_+Pt 510_Bobbi 510 Bobbi 510 Bobbi PlugMRP 540_Bobbi KEXP_+Pt 0.10 0.14 KEXP_+Pt Plug_MRP 510 Bobbi 510_Bobbi 510 Bobbi R13DCLP+

0.16 0.18 R13DCLP+

R13DCLP+

0.11 0.14 R13DCLP+

SpecInt 510 Bobbi KEXP +Pt Page 64 of 325

TR-151, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A Site:

Three Mile Island A/ll hIdications. 11'ith Length and I"dth Outage:

1R14 Tube#

Cal Probe Volt / Origin/

Degrees Percent Location Code TSP - Offset 0.00 90 63 39 77 63 56 47 63 56 47 63 61 6

63 73 6

63 76 126 63 76 5

63 79 95 63 80 96 63 82 96 63 83 95 63 87 95 63 109 156 63 109 104 63 126 108 63 126 108 63 126 167 63 126 167 64 16 33 64 16 33 64 16 33 64 16 33 64 18 33 64 18 33 64 30 21 64 30 110 64 60 23 64 60 23 64 60 23 64 60 23 520HF 51OUL 51OUL 51OUL 51OUL 520HF 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 520HF 51 OUL 540HF 540HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 510UL 520HF 520HF 520HF 520HF 520HF 0.83 0.92 0.31 1.70 0.00 0.50 0.19 0.32 2.29 2.16 0.00 0.00 5.54 0.55 2.90 0.72 0.00 0.19 0.00 0.19 0.00 0.28 0.00 2.65 0.00 0.22 0.00 1.32 0.00 Page 65 of 325 98 101 93 81 0

92 75 108 179 179 0

0 359 8

171 18 0

8 0

10 0

27 0

174 0

26 0

29 35 Axial Cire Dataset 0

CLP ETL 0

fINR 04S 0

INR 05S OD 7

TWD 08S 0

INR 13S 0

NDF LTS 0

NQI LTS 0

INR LTS 0

INR LTS 0

INR LTS 0

INR LTS 0

INF LTS 0

NDF LTS 0

IDC LTS ID 27 TWD 15S 0

DNT LTE 0

VOL UTS 0

CLP UTS ID 9

VOL ETL 0

CLP ETL ID 13 VOL ETL 0

CLP ETL 0

VOL ETL 0

CLP ETL 0

DNT 09S 0

NDF 09S 0

VOL ETL 0

CLP ETL ID 67 SCI ETL 0

ARC ETL

-0.37 35.64 8.66

-0.70 26.50 2.83 2.83 2.57 2.64

-0.24 0.00 0.04 16.58 16.58 22.99 8.68

-23.01

-23.01 1.76 1.76 3.33 3.33

-0.92

-0.92 8.14 8.14

-1.91

-1.91 1.22 1.22 0.10 0.09 KEXP_+Pt 510_Bobbi 510_Bobbi 510_Bobbi 510 Bobbi LTS_+Pt 510_Bobbi 510 Bobbi 510 Bobbi 510_Bobbi 510 Bobbi 510_Bobbi Spec Int 510_Bobbi 540 Bobbi 540 Bobbi R13DCLP+

0.18 0.22 R13DCLP+

KEXP_+Pt 0.16 0.19 KEXP_+Pt KEXP_+Pt 0.16 0.19 KEXP_+Pt KEXP_+Pt 0.15 0.19 KEXP_+Pt 510 Bobbi Spec Int KEXP_+Pt 0.14 0.16 KEXP_+Pt KEXP_+Pt 0.19 KEXP +Pt 18.47 18.47

TR-151, Revision 0 Appendix II Recordable Indications ComponTent:

TMI-OTSG-A Site."

Three Mile Island All Indications. lWith Length and Width Outage:

IR14 Tube#

Cal Probe 64 62 5

64 62 25 64 66 64 66 64 66 64 66 64 66 64 74 64 74 64 74 64 74 64 74 64 85 64 85 64 85 64 85 64 85 64 85 64 85 64 85 25 25 7

7 25 23 23 57 23 23 60 60 60 60 60 60 60 60 64 96 95 64 96 113 64 123 103 64 127 103 64 127 103 64 129 108 64 129 135 64 129 135 64 129 167 65 2 153 65 2 128 65 3

12 65 20 25 65 24 33 51 OUL 520HF 520HF 520HF 540HF 540HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520H1F 520HF 520HF 510UL 520HF 510UL 51OUL 510UL 540HF 520HF 520HF 520HF 520HF 510UL 460PP 510UL 520HF V'olt / Origin/

Degrees Percent 0.74 50 0.00 0

0.21 0.00 0.37 0.27 0.00 33 0

7 83 0

0.00 0

1.20 29 1.36 14 0.30 9

0.00 0

0.74 30 0.00 0

0.00 0

0.51 16 0.44 13 0.00 0

0.61 28 0.00 0

0.23 94 0.00 0

0.24 82 0.60 123 2.85 172 0.61 0.78 0.00 0.00 7

15 0

0 0.00 0

0.17 79 0.47 143 0.53 37 0.00 0

Location Code TSP - Offset 0

NQI LTS 0

NDF LTS 0

VOL 15S 0

CLP 15S 0

BVC 15S 0

NQI LTS 0 NDF LTS 0

CLP ETL 0

VOL ETL 0

PID ETL ID 8

VOL ETL 0

CLP ETL ID 71 VOL ETL 0

CLP ETL 0

CLP ETL ID 22 VOL ETL ID 15 VOL ETL 0

CLP ETL ID 63 VOL ETL 0

CLP ETL 0

NQI LTE 0 NDF LTS 0

INR lOS 0

INR 15S 0

DNT LTE ID 23 TWD UTS 0

VOL UTS 0

CLP UTS 0

RIC UTS 0

NDF 13S 0

NQI 13S 0

AOD UTE 0

INR LTE 0

CLP ETL

-0.30

-0.30 39.71 39.71 39.73

-0.44

-0.44

-2.80

-2.80

-2.80 0.00 0.00 0.23 0.23 1.75 1.75 2.85 2.85 4.92 4.92 12.31

-11.69

-0.34

-0.51 11.01

-0.48

-0.39

-0.39

-0.38 Axial Circ Dataset 510 Bobbi Spec Int Spec Int 0.15 0.20 SpecInt 540_Bobbi 540_Bobbi SpecInt 0.18 0.27 R13DCLP+

R13DCLP+

R13DCLP+

R13DCLP+

0.06 0.11 R13DCLP+

KEXP_+Pt 0.12 0.14 KEXP_+Pt 0.29 0.19 KEXP_+Pt KEXP_+Pt KEXP_+Pt 0.12 0.14 KEXP-+Pt KEXP-+Pt 0.12 0.14 KEXP_+Pt 510 Bobbi Spec_lnt 510 Bobbi 510 Bobbi 510 Bobbi 540_Bobbi R13DCLP+

0.15 0.16 R13DCLP+

R13DCLP+

0.51 0.51 SpecInt 510 Bobbi PlugMRP 510 Bobbi

-0.58 11.55 0.70 0.15 0.19 KEXP -+Pt Page 66 of 325

TR-151, Revision 0 Appendix 11 Recordable Indications Component:

TMI-OTSG-A Site:

Three Mile Island 41/ Indications, 1471ih Length and JW'idth Ozwage:

!R14 Tube#

Cal Probe 65 24 33 65 49 78 65 49 78 65 64 23 65 64 23 65 64 5

65 65 6

65 67 6

65 68 5

65 69 6

65 70 5

65 81 60 65 81 60 65 82 96 65 83 95 65 86 113 65 86 96 65 93 60 65 93 60 65 93 60 65 93 60 65 94 131 65 94 131 65 94 131 65 94 123 65 94 123 65 94 123 65 94 123 65 94 123 65 94 123 65 94 123 65 94 123 520HF 520HF 520HF 520HF 520HF 510UL 510UL 510UL 510UL 51OUL 51OUL 520HF 520HF 51OUL 51OUL 520HF 51OUL 520HF 520HF 520HF 520HF 540HF 540HF 540HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF Volt / Origin!

Location Degrees Percent Code TSP - Offset 0.36 12 ID 17 VOL ETL 0.47 18 0.00 0

0.23 16 0.00 0

2.52 170 0.32 120 3.03 158 3.38 168 6.68 164 6.44 168 0.00 0

0.34 19 0.64 47 2.16 182 0.00 0

0.44 115 0.47 15 0.00 0

1.06 31 0.00 0

0.39 6

0.19 4

0.16 12 0.25 14 0.00 0

0.20 12 0.00 0

0.00 0

0.13 14 0.30 26 0.00 0

ID 27 VOL ETL 0 CLP ETL 0

VOL ETL 0 CLP ETL 0

DNT LTS 0 INR UTS 0 DNT LTS 0

DNT LTS 0 DNT LTS 0 DNT LTS 0

CLP ETL ID 30 VOL ETL 0

INR LTS 0 INR LTS 0 NDF LTS 0 NQI LTS ID 20 VOL ETL 0

CLP ETL ID 76 VOL ETL 0

CLP ETL 0 BVC 15S 0

INR 15S 0

BVC 15S 0

VOL UTS 0

CLP UTS 0

VOL UTS 0 CLP UTS 0

CLP UTS 0

VOL UTS 0

VOL UTS 0

CLP UTS 0.70 1.70 1.70

-0.52

-0.52 0.02 0.42 0.11

-0.09 0.00

-0.02 2.02 2.02 2.49 0.00 1.96 1.96 0.29 0.29 4.27 4.27 35.79 43.15 44.72

-11.13

-11.13

-9.67

-9.67

-3.49

-3.49

-1.76

-1.76 Axial Circ Dataset KEXP_+Pt KEXP-+Pt 0.12 0.14 KEXP_-i+Pt KEXP +Pt 0.11 0.11 KEXP-+Pt 510_Bobbi 510 Bobbi 510 Bobbi 510_Bobbi 510 Bobbi 510 Bobbi 0.23 0.18 KEXP-+Pt KEXP-+Pt 510 Bobbi 510 Bobbi SpecInt 510_Bobbi KEXP_+Pt 0.18 0.18 KEXP_+Pt KEXP_+Pt 0.12 0.18 KEXP_+Pt 540_Bobbi 540_Bobbi 540_Bobbi R 13DCLP+

0.15 0.16 R13DCLP+

R13DCLP+

0.10 0.16 R13DCLP+

0.10 0.16 R13DCLP+

R13DCLP+

R13DCLP+

0.10 0.16 R13DCLP+

Page 67 of 325

TR-151, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A Site:

Three Mile Island All Indications, WI'ith Lenglh and I+'idth Otage:

1R14 Tube#

Cal Probe 65 100 96 65 104 59 65 104 59 65 123 104 65 127 104 65 130 104 65 130 104 66 12 25 66 16 66 16 66 16 66 16 66 16 66 16 66 16 66 16 66 20 66 20 66 20 66 20 66 20 66 20 66 20 66 20 79 79 79 79 79 79 79 79 79 79 79 79 79 79 79 79 66 26 33 66 26 33 66 61 66 61 66 61 66 61 6

25 25 6

66 64 23 66 64 23 66 66 5

66 66 5

51OUL 520HF 520HF 51OUL 51OUL 51OUL 510UL 510UL 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 51OUL 520HF 520HF 510UL 520HF 520HF 51OUL 51OUL V6olt / Origin/

Degrees Percent 0.18 110 0.13 7

0.00 0

0.09 107 1.35 166 2.66 176 5.49 173 0.34 89 0.00 0.70 0.12 0.00 0.21 0.00 0.00 0.09 0.19 0.00 0.00 0.57 0.00 0.48 1.34 0.00 0

28 11 0

15 0

0 16 21 0

0 27 0

24 34 34 ID ID ID 0.32 39 0.00 0

2.84 0.00 0.00 2.82 185 0

0 184 0.00 0

0.21 22 5.24 180 2.96 178 Location Code TSP - Offset 0

INR LTS 0

VOL ETL 0

CLP ETL 0

INR LTE 0

INR LTE 0

DNT 15S 0 DNT LTE 0

INR LTE 0

0 0

0 0

0 0

0 0

0 0

58 0

47 91 0

0 0

0 0

0 0

CLP ETL VOL ETL VOL ETL CLP ETL VOL ETL CLP ETL CLP UTS VOL UTS VOL ETL CLP ETL CLP ETL VOL ETL CLP ETL VOL ETL SCI ETL ARC ETL VOL ETL CLP ETL DNT 05S NDF 05S NDF 05S DNT 05S 0

CLP ETL 0

VOL ETL 0

DNT LTE 0

DNT LTE 5.80

-1.08

-1.08 14.47 9.13

-0.69 10.78 14.99

-6.41

-6.41

-5.06

-5.06

-1.88

-1.88

-3.32

-3.32

-0.92

-0.92 3.16 3.16 3.46 3.46 4.20 4.20

-0.09

-0.09 24.14 24.14 30.24 30.24

-0.42

-0.42 17.34 18.91 Axial Circ Dataset 510 Bobbi KEXP +Pt 0.16 0.19 KEXP_+Pt 510 Bobbi 510 Bobbi 510 Bobbi 510 Bobbi 510 Bobbi 0.11 0.18 R13DCLP+

R13DCLP+

R13DCLP+

0.11 0.18 RI3DCLP+

R 13DCLP+

0.11 0.18 R13DCLP+

0.11 0.09 R13DCLP+

R1 3DCLP+

R13DCLP+

0.11 0.14 RI3DCLP+

0.16 0.18 RI3DCLP+

RI 3DCLP+

0.16 0.14 R13DCLP+

R13DCLP+

R 13DCLP+

0.18 RI3DCLP+

KEXP_+Pt 0.16 0.19 KEXP_+Pt 510 Bobbi Spec Int SpecInt 510 Bobbi 0.14 0.11 KEXP_+Pt KEXP +Pt 510 Bobbi 510 Bobbi Page 68 of 325

TR-151, Revision 0 Appendix II Recordable Indications CoMponent:

TMI-OTSG-A Site:

Three Mile Island All Indications, 4"ith Length and Width Outage.:

1R14 Cal Tube#

66 67 6

66 68 5

66 69 6

66 70 5

66 71 6

66 72 5

66 73 6

66 82 79 66 82 79 66 83 134 66 83 96 66 83 96 66 84 95 66 85 96 66 86 95 66 86 134 66 86 95 66 98 95 66 126 104 66 127 108 66 127 108 66 127 167 66 127 167 67 2 128 67 2 128 67 7 110 67 7

26 67 26 25 Probe 51OUL 51OUL 51OUL 510UL 51OUL 51OUL 51OUL 520HF 520HF 520HF 51OUL 51OUL 510UL 51OUL 51OUL 520HF 51OUL 51OUL 51OUL 540HF 540HF 520HF 520HF 51OUL 51OUL 520HF 51OUL 51OUL Volt/

Origin/

Degrees Percent 6.31 160 8.41 168 12.09 166 20.07 170 12.25 165 6.07 166 3.32 171 0.00 0

0.18 25 0.00 0

0.65 72 2.33 181 2.93 185 4.15 168 7.37 169 0.00 0

0.59 99 0.20 95 2.59 167 0.52 11 ID 3.56 176 0.00 0

0.82 19 0.08 78 5.50 173 0.00 0

0.33 105 0.39 111 Page 69 of 325 Code DNT DNT DNT DNT DNT DNT DNT CLP VOL NDF NQI INR DNT DNT DNT NDF NQI INR DNT TWD DNT CLP VOL INR DNT NDF NQI INR Location TSP - Offset LTS 0.00 LTS

-0.02 LTS 0.00 LTS 0.09 LTS 0.00 LTS 0.07 LTS 0.00 ETL

-2.91 ETL

-2.91 LTS

-0.39 LTS

-0.39 LTS

-0.16 LTS

-0.17 LTS

-0.06 LTS

-0.04 LTS 2.03 LTS 2.03 LLTE 9.08 LTE 11.06 15S 44.88 LTE 10.75 UTS

-1.52 UTS

-1.52 IlS 0.00 LTE 10.54 15S 16.74 15S 16.74 LTE 15.51 Axial Circ Dataset 510 Bobbi 510 Bobbi 510 Bobbi 510_Bobbi 510_Bobbi 510_Bobbi 510 Bobbi 0.12 0.18 R13DCLP+

R13DCLP+

LTS_+Pt 510_Bobbi 510 Bobbi 510_Bobbi 510 Bobbi 510 Bobbi LTS +Pt 510 Bobbi 510_Bobbi 510 Bobbi 540 Bobbi 540_Bobbi 0.14 0.16 RI3DCLP+

R13DCLP+

510 Bobbi 510 Bobbi SpecInt 510 Bobbi 510 Bobbi

TR-151, Revision 0 Appendix II Recordable Indications Coinpon eet:

TMI-OTSG-A Site:

Three Mile Island

.ll Inclications, II ith Length C1nd Width Outage:

IR14 Tube#

Cal Probe 67 44 77 520HF 67 44 77 520HF 67 50 77 520HF 67 50 77 520HF 67 58 23 520HF 67 58 23 520HF 67 63 21 520HF 67 63 21 520HF 67 67 5

51OUL 67 68 6

51OUL 67 69 5

51OUL 67 69 28 520HF 67 69 5

51OUL 67 71 6

51OUL 67 72 5

51OUL 67 82 96 51OUL 67 84 99 510UL 67 85 98 51OUL 67 86 99 51OUL 67 90 131 540HF 67 90 113 520HF 67 93 131 540HF 67 93 123 520HF 67 93 123 520HF 67 93 123 520HF 67 93 123 520HF 67 93 123 520HF 67 93 123 520HF 67 105 59 520HF 67 105 59 520HF 67 105 59 520HF Volt / Origin" Degrees Percent 0.35 0.00 0.25 0.00 0.00 0.54 0.00 0.32 4.11 4.66 0.24 0.00 15.32 24.71 7.41 0.37 2.50 10.34 5.65 1.02 0.00 0.32 0.16 0.00 0.29 0.00 0.00 0.33 0.11 0.00 0.00 21 0

16 0

0 25 0

17 167 165 92 0

170 167 167 135 171 166 168 6

0 6

6 0

20 0

0 14 34 0

0 ID 36 0

ID 22 0

0 0

0 ID 25 0

0 0

0 0

0 0

0 0

0 0

ID 20 0

0 0

0 0

0 0

0 ID 91 0

0 Code VOL CLP VOL CLP CLP VOL CLP VOL DNT DNT NQI NDF DNT DNT DNT INR DNT DNT DNT TWD NDF BVC VOL CLP VOL CLP CLP VOL VOL CLP CLP Location TSP - Offset ETL 0.72 ETL 0.72 ETL 1.22 ETL 1.22 ETL

-0.41 ETL

-0.41 ETL 1.71 ETL 1.71 LTS 0.00 LTS 0.02 LTE 16.85 LTS

-7.15 LTS 0.00 LTS 0.13 LTS

-0.04 LTS 2.60 LTS

-0.17 LTS

-0.02 LTS

-0.08 11S 14.17 11S 14.17 15S 35.71 UTS

-12.51 UTS

-12.51 UTS

-11.19 UTS

-11.19 UTS

-10.57 UTS

-10.57 ETL 2.23 ETL 2.23 ETL 2.95 Axial Circ Dataset KEXP +Pt 0.11 0.14 KEXP_+Pt KEXP +Pt 0.11 0.14 KEXP-+Pt 0.14 0.16 KEXP -+Pt KEXP_+Pt 0.12 0.10 KEXP +Pt KEXP_+Pt 510 Bobbi 510_Bobbi 510 Bobbi Spec Int 510 Bobbi 510_Bobbi 510_Bobbi 510_Bobbi 510_Bobbi 510_Bobbi 510_Bobbi 540 Bobbi SpecInt 540 Bobbi R13DCLP+

0.15 0.16 R13DCLP+

R13DCLP+

0.10 0.16 R13DCLP+

0.10 0.16 R13DCLP+

R 13DCLP+

KEXP +Pt 0.11 0.17 KEXP_ Pt 0.17 0.17 KEXP -+-Pt Page 70 of 325

TR-151, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A Site."

Three Mile island All Indications. With Length and Width Outage:

1R14 Volt/

Origin!

Degrees Percent Location Code TSP - Offset Tube#

67 105 59 67 126 103 67 129 103 67 129 156 67 129 103 67 130 110 67 130 167 67 130 110 67 130 167 67 130 167 67 130 167 67 130 167 68 1 128 68 2 128 68 11 26 68 11 110 68 21 26 68 64 8

68 66 173 68 66 58 68 66 24 68 66 24 68 66 24 68 71 6

68 72 5

68 72 5

68 73 6

68 80 98 68 81 99 68 81 113 68 85 59 Cal Axial Circ Dataset Probe 520HF 51OUL 51OUL 520HF 51 OUL 540HF 520HF 540HF 520HF 520HF 520HF 520HF 51 OUL 51 OUL 51 OUL 520HF 51OUL 460PP 520HF 520HF 510UL 51OUL 510UL 510UL 510UL 51 OUL 510UL 510UL 510UL 520HF 520HF 0.19 12 ID 13 VOL ETL 5.11 172 0 DNT LTE 2.20 82 0

ADI 14S 0.00 0

0 NDF 15S 3.72 170 0

DNT LTE 4.09 174 0

DNT 15S 0.00 0

0 NDF 15S 0.60 7

ID 23 TWD UTS 0.00 0

0 CLP UTS 0.31 12 0 VOL UTS 0.55 19 0

VOL UTS 0.00 0

0 CLP UTS 8.59 175 0

DNT LTE 6.75 173 0

DNT LTE 0.15 82 0 NQI 15S 0.00 0

0 NDF 15S 0.66 110 0

INR LTE 0.00 0

0 OBS UTE 0.00 0

0 NDF LTE 0.00 0

0 RIC LTE 53.90 181 0 DNT LTE 51.14 178 0 DNT LTS 91.34 177 0 DNT LTS 11.76 166 0 DNT LTS 0.15 107 0

INR 13S 11.08 167 0

DNT LTS 5.79 163 0

DNT LTS 1.29 98 0

INR 13S 0.82 86 0

ADI O0S 0.00 0

0 NDF 02S 1.76 35 NT 96 SCI ETL Page 71 of 325 2.95 11.03 30.92

-4.08 10.71

-0.65

-0.65 0.89 0.91 0.91 4.24 4.24 10.61 11.01 9.75 9.75 18.71 0.00 0.56 0.56 0.56

-0.97 0.59 0.19 8.71 0.11

-0.04 16.30 22.95

-15.05 2.03 KEXP +Pt KEXP-+Pt 510 Bobbi 510 Bobbi SpecInt 510 Bobbi 540_Bobbi SpecInt 540_Bobbi 0.18 0.16 R13DCLP+

R13DCLP+

R13DCLP+

0.14 0.16 R13DCLP+

510_Bobbi 510 Bobbi 510 Bobbi Spec Int 510 Bobbi PlugMRP 20.63 Spec mnt 20.63 Spec Int 20.63 510_Bobbi 510 Bobbi 510 Bobbi 510_Bobbi 510 Bobbi 510 Bobbi 510 Bobbi 510 Bobbi 510 Bobbi SpecInt

TR-151, Revision 0 Appendix II Recordable indications Component:

TMI-OTSG-A Site:

Three Mile Island

.4Al Indications. If'ith Length and H'icdth Outag,4e:

1R14 Volt / Origin/

Location Tube#

Cal Probe Degrees Percent Code TSP - Offset Axial Circ Dataset 68 85 59 520HF 0.00 48 0

ARC ETL 2.03 0.26 KEXP_+Pt 68 85 59 520HF 0.14 33 0

INR ETL 2.68 KEXP_+Pt 68 85 59 520HF 0.00 0

0 CLP ETL 2.74 0.17 0.17 KEXP_+Pt 68 85 59 520HF 0.92 24 ID 47 VOL ETL 2.74 KEXP_+Pt 68 85 59 520HF 1.20 20 ID 33 VOL ETL 3.55 KEXP-+Pt 68 85 59 520HF 0.00 0

0 CLP ETL 3.55 0.17 0.22 KEXP-+Pt 68 85 59 520HF 0.76 7

ID 5

VOL ETL 3.90 KEXP_+Pt 68 85 59 520HF 0.00 0

0 CLP ETL 3.90 0.17 0.17 KEXP_+Pt 68 85 59 520HF 0.45 28 ID 63 VOL ETL 4.82 KEXP_+Pt 68 85 59 520HF 0.00 0

0 CLP ETL 4.82 0.17 0.17 KEXP_+Pt 68 86 98 51OUL 3.98 163 0 DNT LTS

-0.06 510 Bobbi 68 124 104 51OUL 2.67 175 0 DNT LTE 10.18 510 Bobbi 68 127 103 51OUL 5.76 174 0 DNT LTE 10.88 510 Bobbi 69 11 26 51OUL 0.06 85 0 INR 11S

-0.25 510 Bobbi 69 17 26 51OUL 3.15 186 0 DNT LTS 25.41 510 Bobbi 69 20 33 520HF 0.57 35 0 VOL ETL

-0.08 KEXP_+Pt 69 20 33 520HF 0.00 0

0 CLP ETL

-0.08 0.16 0.10 KEXP_+Pt 69 44 79 520HF 0.00 0

0 CLP ETL

-4.72 0.12 0.14 R13DCLP+

69 44 79 520HF 0.38 25 0 VOL ETL

-4.72 R13DCLP+

69 44 79 520HF 0.56 235 0 INR ETL

-2.07 R13DCLP+

69 44 77 520HF 0.20 7

0 VOL ETL

-1.76 R13DCLP+

69 44 77 520HF 0.00 0

0 CLP ETL

-1.76 0.11 0.14 R13DCLP+

69 44 79 520HF 0.09 4

0 PRA ETL

-1.60 R13DCLP+

69 44 77 520HF 0.24 15 0

VOL ETL

-0.10 KEXP_+Pt 69 44 77 520HF 0.00 0

0 CLP ETL

-0.10 0.16 0.19 KEXP -+Pt 69 44 79 520HF 0.23 32 0

PRA ETL

-0.05 R13DCLP+

69 44 77 520HF 0.41 35 0

INR ETL 2.06 KEXP_+Pt 69 53 79 520HF 0.29 10 0 VOL ETL

-2.27 R13DCLP+

69 53 79 520HF 0.00 0

0 CLP ETL

-2.27 0.12 0.19 R13DCLP+

69 68 6

51OUL 0.23 106 0 NQI LTS 6.60 510 Bobbi 69 68 25 520HF 0.00 0

0 NDF LTS 6.60 Spec_Int 69 71 25 520HF 0.00 0

0 NDF 13S 4.73 SpecInt 69 71 5

51OUL 0.20 111 0 NQI 13S 4.73 510_Bobbi 69 73 5

510UL 4.25 170 0 DNT LTS 0.04 510 Bobbi Page 72 of 325

TR-151, Revision 0 Appendix II Recordable Indications Componew:

TMI-OTSG-A Site:

Three Mile Island All Indications. flith Length and JTidth Outatge:

1R14 Volt / Origin!

Location Tube#

Cal Probe Degrees Percent Code TSP - Offset Axial Circ Dataset 69 85 99 51OUL 3.09 177 0 DNT LTS

-0.17 510 Bobbi 69 87 99 51OUL 4.08 164 0 DNT LTS

-0.08 510 Bobbi 69 107 59 520HF 0.26 16 0 VOL En

-0.22 KEXP_+Pt 69 107 59 520HF 0.00 0

0 CLP ETL

-0.22 0.13 0.15 KEXP_+Pt 69 124 12 460PP 0.00 0

0 OBS UTE 0.00 PlugMRP 70 1 128 51OUL 0.72 88 0 NQI 14S

-0.29 510 Bobbi 70 1 153 520HF 0.92 110 OD 19 TWD 14S

-0.24 SpecInt 70 6 128 51OUL 0.10 113 0

INR 11S

-0.11 510 Bobbi 70 8 128 51OUL 0.14 34 0

INR 08S

-0.82 510 Bobbi 70 23 33 520HF 0.43 17 0

VOL ETL

-0.12 KEXP-+Pt 70 23 33 520HF 0.00 0

0 CLP ETL

-0.12 0.10 0.14 KEXP_+Pt 70 25 26 51OUL 2.05 180 0

INR 09S 28.94 510_Bobbi 70 25 33 520HF 0.51 19 ID 32 VOL EU 2.97 KEXP_+Pt 70 25 33 520HF 0.00 0

0 CLP ETL 2.97 0.10 0.15 KEXP_+Pt 70 28 25 51OUL 0.43 73 0

ADI 08S 33.14 510 Bobbi 70 28 110 520HF 0.00 0

0 NDF 09S

-5.86 SpecInt 70 30 33 520HF 0.00 0

0 CLP ETL 0.00 0.15 0.15 KEXP_+Pt 70 30 33 520HF 0.62 22 ID 40 VOL ETL 0.00 KEXP_+Pt 70 34 118 51OUL 0.56 78 OD 17 TWD 09S 0.75 510 Bobbi 70 46 77 520HF 0.00 0

0 CLP ETL 2.02 0.05 0.14 KEXP_+Pt 70 46 77 520HF 0.19 12 ID 13 VOL ETL 2.02 KEXP_+Pt 70 46 77 520HF 0.17 25 ID 51 VOL ETL 3.31 KEXP_+Pt 70 46 77 520HF 0.00 0

0 CLP ETL 3.31 0.10 0.14 KEXP_+Pt 70 48 77 520HF 0.32 4

0 VOL ETL

-1.45 KEXP_+Pt 70 48 77 520HF 0.00 0

0 CLP ETL

-1.45 0.11 0.14 KEXP_+Pt 70 48 77 520HF 0.37 6

0 VOL ETL

-0.94 KEXP +Pt 70 48 77 520HF 0.00 0

0 CLP ETL

-0.94 0.11 0.14 KEXP_+Pt 70 48 77 520HF 0.00 0

0 CLP ETL

-0.33 0.16 0.14 KEXP_+Pt 70 48 77 520HF 0.44 13 0 VOL ETL

-0.33 KEXP_+Pt 70 57 25 520HF 0.00 0

0 NDF UTS 1.06 Spec -nt 70 57 4

51OUL 0.16 81 0

NQI UTS 1.06 510 Bobbi Page 73 of 325

TR-151, Revision 0 Appendix II Recordable indications Component:

TMI-OTSG-A Site.

Three Mile Island All Indications, With Length and Width Outage:

IR14 Volt / Origin" Location Tube#

Cal Probe Degrees Percent Code TSP - Offset Axial Circ Dataset 70 59 23 520HF 0.25 17 ID 25 VOL ETL 1.03 KEXP_+Pt 70 59 23 520HF 0.00 0

0 CLP ETL 1.03 0.11 0.11 KEXP-+Pt 70 59 23 520HF 0.24 21 ID 36 VOL ETL 3.01 KEXP_+Pt 70 59 23 520HF 0.00 0

0 CLP ETL 3.01 0.14 0.16 KEXP_+Pt 70 66 3

510UL 0.35 82 OD 10 TWD 12S

-0.77 510 Bobbi 70 66 23 520HF 0.30 17 ID 25 VOL ETL 1.37 KEXP_+Pt 70 66 23 520HF 0.00 0

0 CLP ETL 1.37 0.09 0.11 KEXP-+Pt 70 70 21 520HF 0.00 0

0 CLP ETL

-0.60 0.12 0.10 KEXP_+Pt 70 70 21 520HF 0.25 17 0 VOL ETL

-0.60 KEXP_+Pt 70 76 21 520HF 0.00 0

0 CLP ETL 0.17 0.12 0.10 KEXP_+Pt 70 76 21 520HF 0.17 28 ID 63 VOL ETL 0.17 KEXP_+Pt 70 76 21 520HF 0.17 10 ID 9 VOL ETL 0.32 KEXP_+Pt 70 76 21 520HF 0.00 0

0 CLP ETL 0.32 0.12 0.10 KEXP_+Pt 70 76 21 520HF 0.21 15 ID 20 VOL ETL 2.77 KEXP_+Pt 70 76 21 520HF 0.00 0

0 CLP ETL 2.77 0.18 0.10 KEXP_+Pt 70 76 21 520HF 0.31 15 ID 20 VOL ETL 4.01 KEXP_+Pt 70 76 21 520HF 0.00 0

0 CLP ETL 4.01 0.12 0.15 KEXP_+Pt 70 78 59 520HF 0.29 9

ID 8 VOL ETL 2.42 KEXP_+Pt 70 78 59 520HF 0.00 0

0 CLP ETL 2.42 0.19 0.22 KEXP-+Pt 70 78 59 520HF 0.34 9

ID 8

VOL ETL 3.60 KEXP_+Pt 70 78 59 520HF 0.00 0

0 CLP ETL 3.60 0.19 0.17 KEXP_+Pt 70 78 59 520HF 0.00 0

0 CLP ETL 4.96 0.25 0.17 KEXP_+Pt 70 78 59 520HF 0.28 20 ID 33 VOL ETL 4.96 KEXP_+Pt 70 79 113 520HF 0.00 0

0 NDF 01S

-2.49 SpecInt 70 79 98 510UL 0.36 107 0 NQI LTS 43.51 510 Bobbi 70 81 59 520HF 0.00 0

0 CLP ETL

-0.75 0.13 0.13 KEXP-+Pt 70 81 59 520HF 0.13 15 0

VOL ETL

-0.75 KEXP_+Pt 70 81 59 520HF 0.00 0

0 CLP ETL 0.16 0.13 0.17 KEXP-+Pt 70 81 59 520HF 0.21 29 ID 67 VOL ETL 0.16 KEXP_+Pt 70 81 59 520HF 0.29 11 ID I1 VOL ETL 4.92 KEXP_+Pt 70 81 59 520HF 0.00 0

0 CLP ETL 4.92 0.13 0.17 KEXP-+Pt 70 81 98 51OUL 0.15 78 0

INR LTS 43.31 510 Bobbi 70 84 98 51OUL 0.65 87 0

NQI LTS 2.77 510 Bobbi 70 84 113 520HF 0.00 0

0 NDF LTS 2.77 Spec lnt 70 85 99 51OUL 2.92 178 0

DNT LTS

-0.10 510 Bobbi Page 74 of 325

TR-151. Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A Sile:

Three Mile Island A/1 Indications. W lith Length and Wlidth Outage:

!R14 Volt / Origin/

Location Tube#

Cal Probe Degrees Percent Code TSP - Offset Axial Circ Dataset 70 86 98 51OUL 3.17 166 0

DNT LTS

-0.10 510 Bobbi 70 87 99 51OUL 4.31 167 0

DNT LTS

-0.02 510 Bobbi 70 88 110 540HF 0.27 10 0

BVC 15S 37.31 540 Bobbi 70 88 110 540HF 0.28 8

0 BVC 15S 39.96 540 Bobbi 70 88 123 520HF 0.16 12 0

VOL UTS

-9.32 R13DCLP+

70 88 123 520HF 0.00 0

0 CLP UTS

-9.32 0.15 0.16 R13DCLP+

70 88 123 520HF 0.21 12 0

VOL UTS

-6.63 R13DCLP+

70 88 123 520HF 0.00 0

0 CLP UTS

-6.63 0.19 0.16 R13DCLP+

70 90 59 520HF 0.22 16 ID 22 VOL ETL 2.00 KEXP_+Pt 70 90 59 520HF 0.00 0

0 CLP ETL 2.00 0.19 0.17 KEXP_+Pt 70 90 59 520HF 0.21 17 ID 25 VOL ETL 5.07 KEXP_+Pt 70 90 59 520HF 0.00 0

0 CLP ETL 5.07 0.19 0.17 KEXP_+Pt 70 96 59 520HF 0.00 0

0 CLP ETL 1.96 0.13 0.17 KEXP_+Pt 70 96 59 520HF 0.21 23 ID 43 VOL ETL 1.96 KEXP_+Pt 70 96 59 520HF 0.00 0

0 CLP ETL 4.54 0.13 0.17 KEXP_+Pt 70 96 59 520HF 0.13 21 ID 36 VOL ETL 4.54 KEXP_+Pt 70 96 59 520HF 0.24 18 ID 27 VOL ETL 4.92 KEXP-+Pt 70 96 59 520HF 0.00 0

0 CLP ETL 4.92 0.19 0.17 KEXP_+Pt 70 105 99 51OUL 0.28 78 0

NQI 06S

-0.74 510 Bobbi 70 105 113 520HF 0.45 51 OD 9

TWD 06S

-0.68 SpecInt 70 106 59 520HF 0.00 0

0 CLP ETL 2.75 0.13 0.17 KEXP-+Pt 70 106 59 520HF 0.23 19 ID 30 VOL ETL 2.75 KEXP +Pt 70 124 73 520HF 0.00 0

0 CLP ETL

-1.98 0.20 0.15 KEXP_+Pt 70 124 73 520HF 0.41 30 0

VOL ETL

-1.98 KEXP-+Pt 70 124 104 51OUL 4.54 171 0

DNT LTE 9.43 510 Bobbi 71 1 128 51OUL 9.65 174 0

DNT LTE 10.24 510 Bobbi 71 2 128 510UL 8.83 173 0

DNT LTE 9.91 510 Bobbi 71 2 128 51OUL 3.36 173 0

DNT LTE 12.11 510 Bobbi 71 7 128 51OUL 0.12 100 0

INR llS 0.39 510 Bobbi 71 8 126 400SB 0.00 0

0 ROB 14S 21.57 SlyBob 71 15 26 51OUL 0.23 75 0

NQI 05S

-0.82 510 Bobbi 71 15 110 520HF 0.43 85 OD 4

TWD 05S

-0.72 SpecInt Pane 75 of 325

TR-151., Revision 0 Appendix I1 Recordable Indications Component:

TMI-OTSG-A Site:

Three Mile Island All Indications. II With Length and W idth Outage:

!1R14 Tube#

Cal Probe 71 27 26 71 28 25 71 44 77 71 44 77 71 44 77 71 44 77 71 44 77 71 44 77 71 48 114 71 48 118 71 70 25 71 70 3

71 78 59 71 78 59 71 79 98 71 80 12 71 81 98 71 82 99 71 84 113 71 84 99 71 84 99 71 84 113 71 86 99 71 108 103 71 123 18 71 123 18 71 123 18 71 123 18 71 125 104 71 125 156 71 125 104 51OUL 51OUL 520HF 520HF 520HF 520HF 520HF 520HF 520HF 51OUL 520HF 51 OUL 520HF 520HF 51OUL 460PP 51OUL 51 OUL 520HF 51 OUL 51OUL 520HF 51OUL 510UL 520HF 520HF 520HF 520HF 51OUL 520HF 51OUL Volt/

Origin!

Degrees Percent 0.23 0.27 0.00 0.22 0.23 0.00 0.00 0.18 0.78 0.29 0.76 0.16 0.23 0.00 0.26 0.00 0.17 0.36 0.00 0.44 0.44 0.00 5.08 2.44 1.02 0.00 6.12 0.00 0.91 0.79 6.67 120 91 0

16 12 0

0 15 108 78 50 70 34 0

100 0

155 80 0

141 92 0

162 185 33 0

53 40 84 104 173 Location Code TSP - Offset OD 5 TWD 10S OD 5 TWD 11S 0 CLP ETL 0

VOL ETL 0

VOL ETL 0

CLP ETL 0

CLP ETL 0

VOL ETL OD 11 TWD 09S 0

NQI 09S OD 10 TWD 15S 0 NQI 15S ID 91 VOL ETL 0

CLP ETL 0

INR LTS 0

OBS UTE 0 INR LTS 0

INR LTS 0

NDF 13S 0

NQI 13S 0

NQI LTS 0

NDF LTS 0

DNT LTS 0

INR LTS 0

VOL ETL 0

CLP ETL OD 93 SCI ETL 0 ARC ETL 0

ADI 13S 0

MB 14S 0

DNT LTE

-0.84 0.70

-1.54

-1.54

-1.02

-1.02

-0.13

-0.13

-0.82

-0.78 0.70 0.73 0.02 0.02 43.34 0.00 42.72 2.85

-0.91

-0.91 2.32 2.32

-0.04 7.61

-0.20

-0.20 5.39 5.39 23.87

-12.46 11.09 Axial Circ Dataset 510 Bobbi 510 Bobbi 0.10 0.24 KEXP +Pt KEXP +Pt KEXP +Pt 0.10 0.14 KEXP +Pt 0.13 0.17 KEXP +Pt KEXP_+Pt SpecInt 510_Bobbi Speclnt 510 Bobbi KEXP +Pt 0.16 0.13 KEXP_+Pt 510 Bobbi PlugMRP 510 Bobbi 510 Bobbi Spec Int 510 Bobbi 510 Bobbi SpecInt 510 Bobbi 510 Bobbi KEXP +Pt 0.11 0.22 KEXP +Pt KEXP +Pt 0.22 KEXP_+Pt 510 Bobbi Spec -nt 510 Bobbi Page 76 of 325

TR-151, Revision 0 Appendix II Recordable indications Component:

TMI-OTSG-A Site:

Three Mile Island A;/ h1icaUlions. 11,ith Length and 1icitcIh Outage:

1R14 V olt / Origin!

Degrees Percent 2.68 173 5.64 173 Location Code TSP - Offset 0

DNT LTE 0

DNT LTE 0.40 92 0

NQI LTE 0.00 0

0 NDF LTS 0.23 110 OD 6

TWD 09S 0.16 85 0

INR UTS 0.51 73 0.46 28 0.00 0

Tube#

72 2 128 72 2 128 72 3 128 72 3 153 72 11 128 72 19 26 72 29 117 72 29 79 72 29 79 72 31 77 72 31 77 72 31 77 72 31 77 72 31 77 72 31 77 72 32 118 72 33 118 72 44 118 72 48 118 Cal 0

0 0

Probe 51OUL 51OUL 51OUL 520HF 510UL 51OUL 540HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 510UL 51OUL 510UL 51OUL 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 5.10 174 7.01 176 2.10 176 2.39 176 0.55 0.00 0.41 0.00 0.65 0.00 0.51 0.39 0.00 0.17 0.00 0.18 0.37 0.00 0.10 27 0

25 0

28 0

32 26 0

26 0

24 25 0

16 0

0 0

43 43 0

INR 11S VOL ETL CLP ETL CLP VOL CLP VOL VOL CLP ETL ETL ETL ETL ETL ETL 9.71 10.50 13.59

-10.41

-0.41 0.63 22.68

-1.10

-1.10

-0.75

-0.75 0.48 0.48 0.87 0.87 0

DNT LTE 10.82 0

DNT LTE 10.76 0

INR UTS 0

INR UTS 0

0 0

0 0

0 0

ID 54 0

0 VOL CLP VOL CLP VOL CLP PRA VOL CLP PRA ETL ETL ETL ETL ETL ETL ETL ETL ETL ETL 0

CLP ETL 0

VOL ETL 0

VOL ETL 0

CLP ETL 0

INR ETL

-0.04 0.00

-6.75

-6.75

-2.30

-2.30

-0.23

-0.23

-0.01 1.31 1.31 1.33

-6.79

-6.79

-6.58

-6.58

-5.73 Axial Circ Dataset 510 Bobbi 510_Bobbi 510 Bobbi SpecInt 510 Bobbi 510 Bobbi 540 Bobbi R13DCLP+

0.05 0.14 R13DCLP+

0.10 0.10 KEXP +Pt KEXP +Pt 0.10 0.10 KEXP_+Pt KEXP +Pt KEXP +Pt 0.10 0.14 KEXP +Pt 51 0_Bobbi 510 Bobbi 510 Bobbi 510 Bobbi R13DCLP+

0.23 0.23 R13DCLP+

KEXP +Pt 0.12 0.14 KEXP +Pt KEXP +Pt 0.11 0.14 KEXP +Pt KEXP +Pt KEXP +Pt 0.11 0.14 KEXP +Pt KEXP -- Pt 0.14 0.11 R13DCLP+

R13DCLP+

R13DCLP+

0.14 0.16 R13DCLP+

R13DCLP+

Page 77 of 325 ID ID 0.00 0.66 0.00 0.24 0.93 0.00 0

24 0

23 23 0

72 54 72 54 72 54 72 54 72 54 72 54 72 54 72 54 72 54 72 54 79 79 79 79 77 77 79 77 77 79 72 57 23 72 57 23 72 57 23 72 57 23 72 57 23

TR-151, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A Site:

Three Mile Island All lndicationvs, With Length and Ii'dtih Outage:

1 R14 Volt / Origin/

Degrees Percent 0.40 15 0

0.00 0

0 0.00 0

0 0.74 21 0

0.25 26 0

0.00 0

0 0.35 16 0

0.00 0

0 0.25 39 0

0.00 0

0 0.00 0

0 0.38 27 0

0.27 18 ID 27 0.00 0

0 0.39 20 ID 33 0.00 0

0 0.00 0

0 0.83 26 ID 54 0.00 0

0 0.44 19 ID 30 0.12 58 0

0.41 7

ID 23 Tube#

72 57 23 72 57 23 72 57 23 72 57 23 72 57 23 72 57 23 72 57 23 72 57 23 72 57 23 72 57 23 72 57 23 72 57 23 72 57 23 72 57 23 72 57 23 72 57 23 72 57 23 72 57 23 72 57 23 72 57 23 72 57 23 72 57 7

72 65 3

72 65 25 72 81 98 72 82 99 72 83 113 72 83 113 72 83 110 72 86 133 72 86 133 72 86 133 72 86 110 72 86 110 72 109 103 72 109 156 72 124 79 Cal Probe 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 540-F 51OUL 520HF 51 OUL 51OUL 520HF 520HF 540HF 520HF 520HF 520HF 540HF 540HF 51OUL 520HF 520HF 0

0 0

0 0

0 0

ID 30 1.04 78 0.00 0

0.00 0

Location Code TSP - Offset VOL ETL

-5.15 CLP ETL

-5.15 CLP ETL

-4.15 VOL ETL

-4.15 VOL ETL

-2.50 CLP ETL

-2.50 VOL ETL

-2.25 CLP ETL

-2.25 VOL ETL

-1.75 CLP ETL

-1.75 CLP ETL

-1.30 VOL ETL

-1.30 VOL ETL 0.69 CLP ETL 0.69 VOL ETL 1.60 CLP ETL 1.60 CLP ETL 3.10 VOL ETL 3.10 CLP ETL 3.60 VOL ETL 3.60 INR UTS

-0.14 TWD UTS 2.97 0 NQI 14S

-0.82 0 NDF 14S

-0.82 0

DNT LTS

-0.06 0

DNT LTS VOL ETL CLP ETL BVC UTS VOL CLP NDF DNT TWD ETL ETL ETL LTS UTS

-0.04

-2.23

-2.23 4.80

-3.27

-3.27

-1.89

-0.08 3.92 0 ADI 02S 24.09 0 NDF 03S

-14.91 0

CLP ETL

-2.46 Axial Circ Dataset R13DCLP+

0.14 0.16 RI3DCLP+

0.14 0.22 R13DCLP+

R13DCLP+

Spec Int 0.09 0.11 Spec _Int Spec Int 0.09 0.16 Spec Int Spec nt 0.14 0.16 Spec Int 0.09 0.16 Spec.Int Spec.Int Spec Int 0.09 0.16 Spec _nt Spec Int 0.14 0.16 Spec Int 0.14 0.22 Spec Int Spec Int 0.14 0.16 Spec Int Spec Int R13DCLP+

540 Bobbi 510 Bobbi SpecInt 510 Bobbi 510_Bobbi SpecInt 0.14 0.17 SpecInt 540 Bobbi R! 3DCLP+

0.16 0.15 R13DCLP+

R13DCLP+

540_Bobbi 540_Bobbi 510 Bobbi Spec_mInt 0.30 0.37 R13DCLP+

Page 78 of 325 24 0

0 170 9

0.20 89 0.00 0

6.65 167 7.29 166 0.20 17 0.00 0

0.23 9

0.54 0.00 0.00 2.99 0.50

TR-151, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A Site:

Three Mile Island A.1 Indications, luith Lenglh andI idth Outage:

1R14 Volt/ Origin' Degrees Percent 0.00 0

1.89 29 1.39 28 1.48 30 4.99 172 0.48 170 6.07 171 5.99 174 2.56 171 Cal Tube#

72 124 138 72 124 138 72 124 128 72 124 79 72 125 103 72 126 104 72 126 104 72 128 103 72 129 104 Probe 520PI 520PI 520HF 520HF 51OUL 51 OUL 51OUL 510UL 51OUL 520HF 520HF 540HF 520HF 520HF 540HF 520HF 520HF 540HF 520HF 520HF 540HF 520HF 540HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 51OUL 51OUL 51OUL 510UL 520HF 0

0 0

0 Code CLP VOL PID VOL Location TSP - Offset ETL

-2.46 ETL

-2.46 ETL

-2.46 ETL

-2.46 0

DNT LTE 0

INR LTE 0

DNT LTE 0

DNT LTE 0 DNT LTE VOL CLP BVC VOL CLP BVC CLP VOL INR VOL CLP BVC RIC BVC RIC CLP VOL RIC NDF VOL CLP 12S 12S 12S 12S 12S 12S 12S 12S 12S 12S 12S 12S 12S 12S 12S 13S 13S 13S 13S 13S 13S 10.47 8.81 10.38 10.47 10.87 9.05 9.05 10.67 10.72 10.72 16.30 16.53 16.53 19.50 19.74 19.74 22.52 22.75 33.77 33.77

-14.28

-14.28

-13.76

-6.91

-3.45

-3.45 Axial Circ Dataset 0.25 0.31 PostIn_+Pt PostIn +Pt R13DCLP+

R13DCLP+

510 Bobbi 510 Bobbi 510 Bobbi 510 Bobbi 510 Bobbi Spec Int 0.15 0.17 Spec Int 540 Bobbi Spec nt 0.10 0.11 Spec Int 540 Bobbi 0.15 0.11 Spec Int Spec Int 540_Bobbi R 13DCLP+

0.15 0.17 R13DCLP+

540 Bobbi R1 3DCLP+

540 Bobbi R13DCLP+

0.10 0.11 R13DCLP+

R13DCLP+

R13DCLP+

R13DCLP+

R13DCLP+

0.14 0.16 RI3DCLP+

0 DNT LTE 10.43 0

DNT LTE 0

INR 09S 0

INR 01S 0

VOL ETL 10.49

-0.39 36.62

-6.86 510 Bobbi 510 Bobbi 510 Bobbi 510 Bobbi SlvBdr +Pt Page 79 of 325 16 0

5 3

0 10 0

15 4

16 0

13 0

7 0

0 13 0

0 22 0

4.26 174 5.10 173 0.11 96 0.26 125 0.61 22 0.21 0.00 0.22 0.19 0.00 0.27 0.00 0.38 0.18 0.19 0.00 0.21 0.00 0.25 0.00 0.00 0.20 0.00 0.00 0.09 0.00 72 130 72 130 72 130 72 130 72 130 72 130 72 130 72 130 72 130 72 130 72 130 72 130 72 130 72 130 72 130 72 130 72 130 72 130 72 130 72 130 72 130 156 156 110 156 156 110 156 156 110 156 156 110 156 110 156 135 135 167 167 167 167 73 1 128 73 2 128 73 11 128 73 18 25 73 19 148

TR-151, Revision 0 Appendix II Recordable indications Component.

TMI-OTSG-A Site" Three Mile Island Alli ndicwuons, 1,1'ith Length andl 11 id/h Outage:

1R14 T oht / Origin/

Degrees Percent 0.00 90 0.00 90 0.56 23 0.30 107 0.33 13 0.00 0

0.13 140 Tube#

73 19 148 73 19 148 73 19 148 73 21 26 73 23 121 73 23 121 73 25 26 73 26 25 73 26 121 73 26 121 73 26 121 73 26 121 73 26 121 73 26 121 73 29 79 73 29 79 73 30 25 73 30 25 73 31 33 73 31 33 73 31 33 73 31 33 73 32 77 73 32 77 73 32 118 73 34 118 73 36 77 73 36 77 73 38 118 73 45 118 73 45 114 73 46 114 Cal Probe 520HF 520HF 520HF 51 OUL 520HF 520HF 51 OUL 51 OUL 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 51OUL 51OUL 520HF 520HF 520HF 520HF 520HF 520HF 51OUL 510UL 520HF 520HF 51 OUL 51OUL 520HF 520HF 1.07 0.00 0.00 1.91 28 0

41 32 0.23 8

0.00 0

4.95 174 6.88 176 0.50 10 0.00 0

0 0

0 Location Code TSP - Offset CLP ETL

-6.86 CLP ETL

-6.62 VOL ETL

-6.62 0

INR UTS 0.36 ID 15 VOL ETL 0

CLP ETL 0

INR 11S 0

INR 11S ID 28 VOL ETL 0

CLP ETL ID 29 VOL ETL 0

CLP ETL ID 30 VOL ETL 0

CLP ETL 0

CLP ETL 0 VOL ETL 0

INR 10S 0

INR

]IS ID 58 0

0 ID 71 ID 6

0 0

VOL CLP ARC SCI ETL ETL ETL ETL VOL ETL CLP ETL DNT LTE 0

DNT LTE 0 VOL ETL 0 CLP ETL 0.31 77 OD 10 TWD 08S 2.73 172 0

DNT UTS 0.00 0

0 NDF UTS 0.00 0

0 NDF UTS 1.90 1.90

-0.79

-0.81 1.12 1.12 2.19 2.19 5.14 5.14

-1.82

-1.82

-0.85

-0.83 2.72 2.72 4.89 4.89 1.26 1.26 10.62 10.54

-0.37

-0.37

-0.76

-0.17

-0.17 0.08 Axial Circ 0.09 0.18 0.09 0.18 Dataset SlvBdr +Pt SlvBdr +Pt SlvBdr_+Pt 510_Bobbi R13DCLP+

0.09 0.11 R13DCLP+

510_Bobbi 510_Bobbi R13DCLP+

0.09 0.11 R13DCLP+

R13DCLP+

0.09 0.11 R13DCLP+

R13DCLP+

0.05 0.06 R13DCLP+

0.16 0.18 SlvBdr +Pt SlvBdr +Pt 510 Bobbi 510 Bobbi KEXP +Pt 0.15 0.19 KEXP +Pt 0.22 KEXP_+Pt KEXP +Pt KEXP +Pt 0.10 0.10 KEXP +Pt 510 Bobbi 510_Bobbi KEXP +Pt 0.10 0.10 KEXP +Pt 510 Bobbi 510 Bobbi Specmt SpecInt Page 80 of 325 0.00 0

0.29 27 0.15 77 0.12 81 0.11 0.28 0.00 0.25 0.00 0.19 0.00 112 16 0

18 0

19 0

TR-151, Revision 0 Appendix II Recordable Indications Componen1t:

TMI-OTSG-A Site:

Three Mile Island A1l Indications, I'Vith Length arna' Width Outage:

1R14 Tube#

Cal Probe 73 46 118 73 51 118 73 53 114 73 53 118 73 55 114 73 55 118 73 57 118 73 57 114 73 59 25 73 59 3

73 64 4

73 64 25 73 66 23 73 66 23 73 66 23 73 66 23 73 76 98 73 79 99 73 80 98 73 81 99 73 82 98 73 82 98 73 85 99 73 89 113 73 89 99 73 116 104 73 121 103 73 128 167 73 128 167 73 128 110 51OUL 51OUL 520HF 51 OUL 520HF 51 OUL 51 OUL 520HF 520HF 51OUL 51OUL 520HF 520HF 520HF 520HF 520HF 510UL 51OUL 51OUL 51OUL 510UL 510UL 51OUL 520HF 510UL 51OUL 51OUL 520HF 520HF 540HF V'oltt/ Origin!

Degrees Percent 2.62 170 0.14 87 0.00 0

2.65 167 0.51 85 0.50 80 2.92 170 0.00 0

0.00 0

2.77 170 0.14 109 0.00 0

0.22 17 0.00 0

0.44 21 0.00 0

2.64 175 2.91 175 10.19 162 18.77 169 6.54 166 0.42 113 5.04 163 0.00 0

0.19 85 4.01 176 4.29 174 0.22 13 0.00 0

0.39 3

OD ID 3

Location Code TSP - Offset 0

DNT UTS 0.09 0

INR 09S

-0.77 0

NDF UTS 0.02 0

DNT UTS 0.02 8 TWD 08S

-0.75 0

NQI 08S

-0.74 0

DNT UTS 0.10 0

NDF UTS 0.10 0

NDF UTS 0.18 0

DNT UTS 0.18 0

NQI 13S 0.15 0

NDF 13S 0.15 0

VOL ETL

-3.59 0

CLP ETL

-3.59 6

VOL ETL 0.69 0

CLP ETL 0.69 0

DNT LTS 0.00 0

DNT LTS

-0.17 0

DNT LTS

-0.04 0

DNT LTS 0.00 0

DNT LTS 0.02 0

INR LTS 2.81 0

DNT LTS

-0.10 0 NDF 08S 12.17 0

NQI 08S 12.17 0

DNT 09S 15.23 0

DNT LTE 11.19 0

VOL 15S 13.56 0

CLP 15S 13.56 0

INR 15S 13.59 Axial Circ Dataset 510 Bobbi 510 Bobbi Spec Int 510_Bobbi Spec Int 510 Bobbi 510 Bobbi SpecInt SpecInt 510_Bobbi 510 Bobbi SpecInt R13DCLP+

0.09 0.11 R13DCLP+

R13DCLP+

0.09 0.12 R13DCLP+

510 Bobbi 510 Bobbi 510_Bobbi 510 Bobbi 510 Bobbi 510_Bobbi 510 Bobbi Spec Int 510 Bobbi 51 0_Bobbi 510 Bobbi R13DCLP+

0.14 0.16 R13DCLP+

540 Bobbi Page 81 of 325

TR-151, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A Site:

Three Mile Island All h7dications, 117th Length wid Jic'idth Outage:

1R14 Tube#

Cal Probe Volt/ Origin/

Degrees Percent Location Code TSP - Offset Axial Circ Dataset 0 DNT LTE 0

NQI 14S 0 NDF 15S 0

DNT LTE 0

DNT LTE 0

DNT LTE 73 129 103 73 130 104 73 130 156 73 130 104 74 1 128 74 32 118 74 33 77 74 33 77 74 33 77 74 33 77 74 33 118 74 33 118 74 33 148 74 34 118 74 34 148 74 35 77 74 35 77 74 35 77 74 35 77 74 35 77 74 35 77 74 35 118 74 36 78 74 36 78 74 36 78 74 36 78 74 36 78 74 36 78 74 36 78 74 36 78 74 36 78 74 36 78 74 36 78 74 36 78 74 36 114 74 36 118 3.37 172 0.44 112 0.00 0

2.79 170 3.75 171 5.39 175 510_Bobbi 510 Bobbi Spec Int 510_Bobbi 510 Bobbi 510 Bobbi 51OUL 51OUL 520HF 510UL 51OUL 51OUL 520HF 520HF 520HF 520HF 51 OUL 51 OUL 520HF 51OUL 520HF 520HF 520HF 520HF 520HF 520HF 520HF 51OUL 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 51OUL Page 82 of 325 11.52 32.17

-2.83 11.15 10.71 10.66

-0.04

-0.04 0.52 0.52 10.32

-0.08

-0.08

-0.06

-0.06

-0.81

-0.81

-0.05

-0.05 4.05 4.05

-0.02

-0.36

-0.36 0.04 0.04 1.80 1.80 2.12 2.12 2.22 2.22 3.53 3.53

-0.04

-0.04 1.08 0.00 0.52 0.00 9.42 2.89 0.00 20 0

20 0

174 169 0

0 VOL ETL 0

CLP ETL ID 33 VOL ETL 0

CLP ETL 0

DNT LTE 0 DNT UTS 0

NDF UTS 0 DNT UTS 0

NDF UTS 0

VOL ETL 0

CLP ETL 0

CLP ETL 0

VOL ETL NT 100 VOL ETL 0

CLP ETL 0 DNT UTS 0 CLP ETL 0

VOL ETL ID 76 VOL ETL 0

CLP ETL ID 76 VOL ETL 0

CLP ETL 0

CLP ETL ID 33 VOL ETL ID 43 VOL ETL 0

CLP ETL ID 86 VOL ETL 0

CLP ETL 0

NDF UTS 0

DNT UTS 2.68 168 0.00 0

KEXP +Pt 0.15 0.24 KEXP +Pt KEXP +Pt 0.15 0.24 KEXP +Pt 510 Bobbi 510_Bobbi SlvBdr +Pt 510 Bobbi SlvBdr_+Pt KEXP +Pt 0.13 0.14 KEXP +Pt 0.10 0.14 KEXP +Pt KEXP +Pt KEXP +Pt 0.10 0.19 KEXP +Pt 510 Bobbi 0.12 0.13 KEXP_+Pt KEXP_+Pt KEXP_+Pt 0.18 0.13 KEXP_+Pt KEXP_+Pt 0.12 0.22 KEXP +Pt 0.12 0.15 KEXP +Pt KEXP +Pt KEXP +Pt 0.18 0.18 KEXP_+Pt KEXP +Pt 0.18 0.27 KEXP +Pt SpecInt 510 Bobbi 0.19 0.00 0.00 0.49 3.10 0.00 3.15 40 0

0 22 36 0

167 0.00 0

0.56 27 1.02 31 0.00 0

0.37 31 0.00 0

0.00 0

0.57 20 0.70 23 0.00 0

1.26 33 0.00 0

0.00 0

3.10 167

TR-151, Revision 0 Appendix II Recordable indications Component:

TMI-OTSG-A Site:

Three Mile Island A11 Inldicalions, fII/th Lengih and Width Outage:

1R14 Volt / Origin/

Location Tube#

Cal Probe Degrees Percent Code TSP - Offset, Axial Circ Dataset 74 37 114 520HF 0.00 0

0 NDF UTS

-0.06 SpecInt 74 37 118 51OUL 3.13 172 0

DNT UTS

-0.06 510 Bobbi 74 38 78 520HF 0.23 15 ID 20 VOL ETL 0.85 KEXP_+Pt 74 38 78 520HF 0.00 0

0 CLP ETL 0.85 0.12 0.14 KEXP_+Pt 74 39 77 520HF 0.00 0

0 CLP ETL 1.77 0.10 0.19 KEXP_+Pt 74 39 77 520HF.

1.48 26 ID 54 VOL ETL 1.77 KEXP_+Pt 74 39 77 520HF 1.20 24 ID 47 VOL ETL 4.79 KEXP_+Pt 74 39 77 520HF 0.00 0

0 CLP ETL 4.79 0.10 0.19 KEXP_+Pt 74 39 114 520HF 0.00 0

0 NDF UTS

-0.06 SpecInt 74 39 118 51OUL 3.00 170 0

DNT UTS

-0.06 510_Bobbi 74 40 118 51OUL 2.74 170 0

DNT UTS

-0.04 510 Bobbi 74 40 114 520HF 0.00 0

0 NDF UTS

-0.04 Spec Int 74 41 114 520HF 0.00 0

0 NDF UTS

-0.02 SpecInt 74 41 118 510UL 2.74 172 0

DNT UTS

-0.02 510 Bobbi 74 42 114 520HF 0.00 0

0 NDF UTS 0.00 SpecInt 74 42 118 51OUL 2.61 176 0

DNT UTS 0.00 510 Bobbi 74 43 118 51OUL 2.79 172 0

DNT UTS

-0.08 510 Bobbi 74 43 114 520HF 0.00 0

0 NDF UTS

-0.08 Spec Int 74 44 78 520HF 0.23 27 0 VOL ETL

-0.44 KEXP_+Pt 74 44 78 520HF 0.00 0

0 CLP ETL

-0.44 0.12 0.14 KEXP_+Pt 74 44 118 510UL 3.21 171 0

DNT UTS 0.00 510 Bobbi 74 44 114 520HF 0.00 0

0 NDF UTS 0.00 SpecInt 74 45 77 520HF 0.00 0

0 CLP ETL

-0.89 0.10 0.10 KEXP_+Pt 74 45 77 520HF 0.20 9

0 VOL ETL

-0.89 KEXP_+Pt 74 45 77 520HF 0.00 0

0 CLP ETL

-0.09 0.13 0.17 KEXP_+Pt 74 45 77 520HF 0.44 21 0

VOL ETL

-0.09 KEXP_+Pt 74 45 77 520HF 0.00 0

0 CLP ETL 0.95 0.10 0.14 KEXP_+Pt 74 45 77 520HF 0.32 10 ID 9

VOL ETL 0.95 KEXP_+Pt 74 45 114 520HF 0.00 0

0 NDF UTS

-0.04 SpecInt 74 45 118 51OUL 2.81 170 0

DNT UTS

-0.04 510 Bobbi 74 46 118 510UL 2.52 173 0

DNT UTS 0.39 510 Bobbi 74 46 114 520HF 0.00 0

0 NDF UTS 0.39 Spec Int 74 47 118 51OUL 5.21 175 0

DNT LTE 10.85 510 Bobbi 74 47 118 51OUL 2.60 175 0

DNT UTS

-0.06 510 Bobbi Page 83 of 325

TR-151, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A Site:

Three Mile Island All Idicuiions, ti'itth Length and ihidth Outage:

1R14 Volt / Origin!

Location Tube#

Cal Probe Degrees Percent Code TSP - Offset Axial Circ Dataset 74 47 114 520HF 0.00 0

0 NDF UTS

-0.06 SpecInt 74 48 118 51OUL 6.15 176 0

DNT LTE 10.94 510 Bobbi 74 48 114 520HF 0.00 0

0 NDF UTS

-0.04 Spec Int 74 48 118 510UL 3.23 172 0

DNT UTS

-0.04 510 Bobbi 74 49 118 51OUL 2.49 177 0

INR UTS 0.00 510_Bobbi 74 50 113 540HF 0.35 357 0

INR 15S 45.51 540 Bobbi 74 50 78 520HF 2.62 41 OD 98 SCI ETL 1.06 KEXP +Pt 74 50 78 520HF 0.00 40 0 ARC ETL 1.06 0.21 KEXP +Pt 74 50 114 520HF 0.00 0

0 CLP UTS

-0.93 0.09 0.17 Spec Int 74 50 114 520HF 0.60 25 0 VOL UTS

-0.93 Spec Int 74 50 113 540HF 2.99 173 0 DNT UTS 0.03 540 Bobbi 74 50 114 520HF 0.00 0

0 NDF UTS 0.03 SpecInt 74 51 77 520HF 0.45 15 ID 20 VOL ETL 0.87 KEXP +Pt 74 51 77 520HF 0.00 90 0

CLP ETL 0.87 0.10 0.19 KEXP +Pt 74 51 77 520HF 0.43 15 ID 20 VOL ETL 1.97 KEXP +Pt 74 51 77 520HF 0.00 90 0

CLP ETL 1.97 0.10 0.09 KEXP +Pt 74 51 114 520HF 0.00 0

0 NDF UTS 0.00 Spec Int 74 51 118 51OUL 3.21 171 0

DNT UTS 0.06 510 Bobbi 74 52 114 520HF 0.00 0

0 NDF UTS 0.00 Spec Int 74 52 118 51OUL 3.42 171 0

DNT UTS 0.00 510 Bobbi 74 53 77 520HF 0.39 18 ID 27 SCI ETL 0.00 KEXP +Pt 74 53 77 520HF 0.00 26 0 ARC ETL 0.00 0.14 KEXP +Pt 74 53 77 520HF 0.00 0

0 RPD ETL 0.00 KEXP +Pt 74 53 130 520HF 0.48 15 0 PID ETL 0.00 KEXP +Pt 74 53 118 51OUL 2.67 173 0 DNT UTS 0.00 510_Bobbi 74 53 114 520HF 0.00 0

0 NDF UTS 0.00 SpecInt 74 54 78 520HF 0.00 0

0 CLP ETL

-4.00 0.12 0.19 R13DCLP+

74 54 78 520HF 1.25 28 0

VOL ETL

-4.00 R13DCLP+

74 54 164 520HF 1.40 32 0

PID ETL

-4.00 RI3DCLP+

74 54 78 520HF 1.09 26 0

VOL ETL

-0.40 KEXP +Pt 74 54 78 520HF 0.00 0

0 CLP ETL

-0.40 0.12 0.24 KEXP +Pt 74 54 78 5201F 0.33 17 ID 25 VOL ETL 1.65 KEXP +Pt 74 54 78 520HF 0.00 0

0 CLP ETL 1.65 0.12 0.19 KEXP +Pt 74 54 78 520HF 0.00 0

0 CLP ETL 2.33 0.12 0.14 KEXP +Pt 74 54 78 520HF 0.30 20 ID 33 VOL ETL 2.33 KEXP +Pt 74 54 78 520HF 0.41 17 ID 25 VOL ETL 3.70 KEXP +Pt 74 54 78 520HF 0.00 0

0 CLP ETL 3.70 0.17 0.19 KEXP -Pt Page 84 of 325

TR-151, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A Site:

Three Mile Island A/I Idclicafions, lf'ith Length and Hicdth Outage:

1R14 Volt Origin!

Location Tube#

Cal Probe Degrees Percent Code TSP - Offset Axial Circ Dataset 74 54 78 520HF 0.56 35 NT 96 VOL ETL 4.90 KEXP +Pt 74 54 78 520HF 0.00 0

0 CLP ETL 4.90 0.12 0.14 KEXP +Pt 74 54 78 520HF 0.00 0

0 CLP ETL 5.36 0.17 0.19 KEXP +Pt 74 54 78 520HF 0.62 21 ID 36 VOL ETL 5.36 KEXP +Pt 74 54 113 540HF 2.99 173 0

DNT UTS 0.00 540 Bobbi 74 54 133 520HF 0.71 10 0

VOL UTS 0.25 R13DCLP+

74 54 133 520HF 0.00 0

0 CLP UTS 0.25 0.25 0.11 R13DCLP+

74 54 113 540HF 0.47 10 0

INR UTS 2.72 540_Bobbi 74 55 113 540HF 2.52 176 0

DNT UTS 0.03 540 Bobbi 74 55 114 520HF 0.00 0

0 RBD UTS 0.05 SpecInt 74 55 177 520HF 0.66 24 0

VOL UTS 0.07 SpecInt 74 55 177 520HF 0.00 0

0 CLP UTS 0.07 0.13 0.11 SpecInt 74 55 114 520HF 0.31 22 0

VOL UTS 1.41 SpecInt 74 55 114 520HF 0.00 0

0 CLP UTS 1.41 0.14 0.17 SpecInt 74 56 118 51OUL 3.26 172 0

DNT UTS 0.04 510 Bobbi 74 56 114 520HF 0.00 0

0 NDF UTS 0.04 SpecInt 74 57 25 520HF 0.00 0

0 NDF UTS 0.04 SpecInt 74 57 4

51OUL 2.84 175 0

DNT UTS 0.04 510 Bobbi 74 58 3

51OUL 2.87 171 0 DNT UTS 0.09 510 Bobbi 74 58 25 520HF 0.00 0

0 NDF UTS 0.09 SpecInt 74 59 23 520HF 0.00 0

0 CLP ETL 0.59 0.13 0.17 KEXP_+Pt 74 59 23 520HF 0.45 17 ID 25 VOL ETL 0.59 KEXP-+Pt 74 59 23 520HF 0.70 23 ID 43 SCI ETL 2.61 KEXP_+Pt 74 59 23 520HF 0.00 36 0

ARC ETL 2.61 0.19 KEXP-+Pt 74 59 23 520HF 0.00 0

0 CLP ETL 3.57 0.09 0.14 KEXP +Pt 74 59 23 520HF 0.35 20 ID 33 VOL ETL 3.57 KEXP +Pt 74 59 23 520HF 0.00 31 0

ARC ETL 3.66 0.17 KEXP +Pt 74 59 23 520HF 0.85 24 ID 47 SCI ETL 3.66 KEXP +Pt 74 59 4

51OUL 2.79 177 0

DNT UTS 0.06 510 Bobbi 74 59 25 520HF 0.00 0

0 NDF UTS 0.06 Specmnt 74 60 23 520HF 0.00 36 0

ARC ETL 0.12 0.19 KEXP_+Pt 74 60 160 520HF 0.00 0

0 RIC ETL 0.12 SpecInt 74 60 173 520HF 0.51 29 0 PID ETL 0.12 KEXP?+Pt 74 60 23 520HF 0.00 0

0 RPD ETL 0.12 KEXP_+Pt 74 60 23 520HF 0.53 36 NT 100 SCI ETL 0.12 KEXP +Pt 74 60 23 520HF 0.00 31 0

ARC ETL 1.07 0.17 KEXP +Pt 74 60 23 520HF 0.56 29 ID 67 SCI ETL 1.07 KEXP-+Pt Page 85 of 325

TR-15 1, Revision 0 Appendix II Recordable indications Componewn:

TMI-OTSG-A Site:

Three Mile Island A411 Indicalions. 1,11i7h Length anci JJ'idth Outage::

1R14 J 'olt / Origin!

Degrees Percent Location Code TSP - Offset Tube#

74 60 23 74 60 23 74 60 23 74 60 23 74 60 25 74 60 3

74 61 4

74 61 25 74 62 23 74 62 23 74 69 3

74 70 4

74 71 3

74 75 101 74 76 101 74 77 102 74 78 59 74 78 59 74 78 59 74 78 59 74 78 101 74 81 102 74 86 59 74 86 59 74 99 59 74 99 59 74 113 103 74 113 156 74 116 104 74 119 103 Cal Probe 520HF 520HF 520HF 520HF 520HF 51OUL 51OUL 520HF 520HF 520HF 51OUL 51OUL 51OUL 51 OUL 51OUL 510UL 520HF 520HF 520HF 520HF 51OUL 51 OUL 520HF 520HF 520HF 520HF 51 OUL 520HF 5 1 OUL 510UL 0.51 27 ID 58 SCI ETL 0.00 31 0 ARC ETL 0.43 29 ID 67 SCI ETL 0.00 26 0

ARC ETL 0.00 0

0 NDF UTS 2.93 173 0 DNT UTS 3.13 174 0

DNT UTS 0.00 0

0 NDF UTS 0.89 29 ID 67 VOL ETL 0.00 0

0 CLP ETL 3.91 162 0

DNT LTS 3.03 170 0

DNT LTS 2.80 172 0 DNT LTS 9.95 168 0 DNT LTS 27.37 170 0

DNT LTS 15.49 167 0

DNT LTS 0.40 18 ID 18 VOL ETL 0.00 0

0 CLP ETL 0.62 23 ID 43 VOL ETL 0.00 0

0 CLP ETL 5.75 165 0

DNT LTS 4.14 165 0

DNT LTS 0.29 20 ID 33 VOL ETL 0.00 0

0 CLP ETL 0.18 12 ID 13 VOL ETL 0.00 0

0 CLP ETL 1.66 77 0

ADI 09S 0.00 0

0 NDF 09S 5.18 173 0

DNT LTE 2.49 2.49 3.12 3.12 0.02 0.02 0.06 0.06 0.33 0.33

-0.38

-0.08

-0.45

-0.02 0.04

-0.02 2.65 2.65 3.01 3.01 0.04

-0.04 0.25 0.25 2.30 2.30 12.04 12.04 10.77 9.48 510 Bobbi Page 86 of 325 0 DNT LTE Axial Circ Dataset KEXP +Pt 0.17 KEXP_+Pt KEXP +Pt 0.14 KEXP +Pt Spec Int 510_Bobbi 510 Bobbi Spec lnt KEXP +Pt 0.10 0.22 KEXP_+Pt 510 Bobbi 510 Bobbi 510 Bobbi 510 Bobbi 510 Bobbi 510 Bobbi KEXP +Pt 0.19 0.21 KEXP +Pt KEXP +Pt 0.19 0.21 KEXP +Pt 5!0_Bobbi 510 Bobbi KEXP +Pt 0.19 0.17 KEXP_+Pt KEXP +Pt 0.13 0.13 KEXP +Pt 510 Bobbi Spec lnt 510_Bobbi 4.89 172

TR-151, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A Site.:

Three Mile Island Al! Indications, With Length uncl W-icdth outage:

1RI14 Cal Tube#

74 123 103 74 123 103 75 18 128 75 18 153 75 20 128 75 33 128 75 33 171 75 34 128 75 36 148 75 36 118 75 37 114 75 37 118 75 38 114 75 38 48 75 38 114 75 38 114 75 39 47 75 39 114 75 40 48 75 40 114 75 41 47 75 41 114 75 41 114 75 41 47 75 42 48 75 42 114 75 43 114 75 43 47 75 44 114 75 44 48 75 45 114 75 45 47 Probe 51OUL 51OUL 51 OUL 520HF 51OUL 51OUL 520HF 51OUL 520HF 51OUL 520HF 51OUL 520HF 51OUL 520HF 520HF 510UL 520HF 51OUL 520HF 51OUL 520HF 520HF 51OUL 51OUL 520HF 520HF 5 !OUL 520HF 51OUL 520HF 51OUL Page 87 of 325 Volt / Origin!

Degrees Percent 2.24 177 0

3.85 173 0

0.12 62 0

0.00 0

0 0.15 156 0

0.13 89 0

1.05 87 OD 20 0.24 129 OD 7

0.00 0

0 2.50 173 0

0.00 0

0 3.15 168 0

0.00 0

0 3.21 176 0

0.20 33 0

0.00 0

0 2.78 175 0

0.00 0

0 3.26 174 0

0.00 0

0 0.29 107 0

0.83 97 OD 12 0.00 0

0 3.07 174 0

2.78 175 0

0.00 0

0 0.00 0

0 3.01 173 0

0.00 0

0 3.04 176 0

0.00 0

0 3.06 176 0

Location Code TSP - Offset INR LTE 9.87 DNT LTE 10.73 NQI 14S

-0.76 NDF 14S

-0.76 INR 14S 12.93 NQI 05S

-0.81 TWD 05S

-0.75 TWD 05S

-0.78 NDF UTS

-0.06 DNT UTS

-0.06 NDF UTS

-0.61 DNT UTS

-0.61 NDF UTS 0.12 DNT UTS 0.12 VOL UTS 3.80 CLP UTS 3.80 DNT UTS 0.00 NDF UTS 0.00 DNT UTS 0.04 NDF UTS 0.04 NQI 05S

-0.78 TWD 05S

-0.72 NDF UTS 0.00 DNT UTS 0.00 DNT UTS 0.00 NDF UTS 0.00 NDF UTS 0.00 DNT UTS 0.00 NDF UTS

-0.02 DNT UTS

-0.02 NDF UTS 0.00 DNT UTS 0.00 Axial Cire Dataset 510 Bobbi 510_Bobbi 510 Bobbi SpecInt 510 Bobbi 510_Bobbi SpecInt 510 Bobbi SlvBdr +Pt 510 Bobbi Spec Int 510 Bobbi Spec Int 510 Bobbi Spec Int 0.13 0.18 SpecInt 510 Bobbi SpecInt 510 Bobbi Spec Int 510 Bobbi Specmnt SpecInt 510 Bobbi 510 Bobbi SpecInt SpecInt 510 Bobbi SpecInt 510 Bobbi Spec nt 510 Bobbi

TR-151, Revision 0 Appendix II Recordable Indications Comlp)onenl:

TMI-OTSG-A Site:

Three Mile Island A4ll IdClicat ions, 1ith Length and 11,cdth Outage:

1R14 Tube#

Cal Probe 75 46 48 75 46 114 75 46 114 75 46 48 75 47 47 75 47 114 75 47 47 75 49 47 75 49 114 75 49 47 75 51 47 75 51 114 75 52 114 75 52 48 75 53 47 75 53 114 75 54 48 75 54 114 75 55 47 75 55 114 75 56 48 75 56 114 75 56 114 75 56 48 75 57 47 75 57 114 75 58 4

75 58 25 75 59 3

75 59 25 75 60 25 75 60 4

51OUL 520HF 520HF 51OUL 51 OUL 520HF 51OUL 51OUL 520HF 51OUL 51OUL 520HF 520HF 51OUL 51OUL 520HF 51OUL 520HF 51OUL 520HF 51OUL 520HF 520HF 51OUL 51OUL 520HF 51OUL 520HF 51OUL 520HF 520HF 51OUL Volt / Origin/

Degrees Percent 0.28 0.98 0.00 2.94 5.23 0.00 2.79 7.08 0.00 3.46 3.92 0.00 0.00 3.77 3.48 0.00 3.35 0.00 3.15 0.00 0.30 1.06 0.00 3.30 3.71 0.00 3.81 0.00 3.07 0.00 0.00 3.62 71 104 0

174 177 0

175 176 0

172 170 0

0 176 174 0

177 0

176 0

58 100 0

177 175 0

173 0

176 0

0 179 0

OD 13 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

OD 14 0

0 0

0 0

0 0

0 0

0 Location Code TSP-Offset NQI 05S

-0.77 TWD 05S

-0.70 NDF UTS 0.02 DNT UTS 0.02 DNT LTE 10.45 NDF UTS 0.00 DNT UTS 0.00 DNT LTE 10.51 NDF UTS 0.00 DNT UTS 0.00 DNT UTS 0.00 NDF UTS 0.00 NDF UTS 0.04 DNT UTS 0.04 DNT UTS 0.00 NDF UTS 0.00 DNT UTS 0.05 NDF UTS 0.05 DNT UTS 0.00 NDF UTS 0.00 NQI 05S

-0.80 TWD 05S

-0.70 NDF UTS

-0.80 DNT UTS 0.00 DNT UTS

-0.02 NDF UTS

-0.02 DNT UTS 0.06 NDF UTS 0.06 DNT UTS 0.09 NDF UTS 0.09 NDF UTS 0.08 DNT UTS 0.08 Page 88 of 325 Axial Circ Dataset 510 Bobbi Spec Int Spec Int 510 Bobbi 510 Bobbi Spec Int 510_Bobbi 510 Bobbi Spec Int 510 Bobbi 510 Bobbi SpecInt Spec Int 510 Bobbi 510 Bobbi SpecInt 510 Bobbi SpecInt 510 Bobbi SpecInt 510_Bobbi Spec Int Spec Int 510 Bobbi 510 Bobbi SpecInt 510 Bobbi SpecInt 510 Bobbi SpecInt Spec Int 510 Bobbi

TR-151, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A Site:

Three Mile Island All Indications, With Length anc0 lWiclth Outage.

1R14 Cal Tube#

75 61 25 75 61 3

75 62 4

75 62 25 75 62 25 75 62 4

75 63 25 75 63 3

75 69 3

75 70 4

75 71 3

75 75 102 75 76 101 75 77 59 75 77 59 75 77 59 75 77 59 75 77 102 75 78 101 75 79 102 75 79 102 75 81 110 75 81 123 75 81 123 75 101 113 75 101 102 75 112 104 75 117 103 75 117 156 75 117 103 75 118 104 Probe 520HF 51OUL 51 OUL 520HF 520HF 510UL 520HF 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 520HF 520HF 520HF 520HF 510UL 51 OUL 51OUL 51OUL 540HF 520HF 520HF 520HF 51 OUL 51OUL 51OUL 520HF 510UL 51OUL olt / Origin!

Degrees Percent 0.00 0

0 3.57 176 0

0.09 80 0

0.00 0

0 0.00 0

0 4.87 174 0

0.00 0

0 3.53 178 0

6.29 170 0

15.89 166 0

3.24 168 0

4.46 171 0

17.15 170 0

0.00 0

0 0.71 25 ID 51 0.36 13 ID 15 0.00 0

0 18.32 169 0

7.10 167 0

0.82 93 0

4.80 164 0

0.57 9

ID 30 0.38 19 0

0.00 0

0 0.00 0

0 5.90 179 0

0.60 94 0

0.31 72 0

0.00 0

0 4.88 175 0

Code NDF DNT NQI NDF NDF DNT NDF DNT DNT DNT DNT DNT DNT CLP VOL VOL CLP DNT DNT INR DNT TWD VOL CLP NDF DNT INR NQI NDF DNT 0

DNT LTE 8.36 510 Bobbi Page 89 of 325 Location TSP - Offset UTS 0.00 UTS 0.00 LTS 2.42 LTS 2.42 UTS

-0.02 UTS

-0.02 UTS 0.00 UTS 0.00 LTS 0.07 LTS 0.00 LTS

-0.28 LTS

-0.08 LTS 0.00 ETL 2.53 ETL 2.53 ETL 2.98 ETL 2.98 LTS 0.04 LTS

-0.04 01S 18.65 LTS

-0.02 15S 35.49 UTS

-11.28 UTS

-11.28 1lS 4.18

!IS 4.18 14S 18.51 10S 0.29 10S 0.29 LTE 11.21 2.74 171 Axial Circ Dataset Spec_Int 510_Bobbi 510 Bobbi Spec Int Spec lnt 510_Bobbi Spec Int 510_Bobbi 510_Bobbi 510_Bobbi 510_Bobbi 510_Bobbi 510_Bobbi 0.20 0.17 KEXP +Pt KEXP +Pt KEXP +Pt 0.13 0.13 KEXP +Pt 510 Bobbi 510_Bobbi 510 Bobbi 510 Bobbi 540 Bobbi R13DCLP+

0.15 0.16 RI3DCLP+

Spec Int 510_Bobbi 510_Bobbi 510 Bobbi Spec Int 510 Bobbi

TR-151, Revision 0 Appendix II Recordable indications Component:

TMI-OTSG-A Site:

Three Mile Island All Indications. Wit]7 Length and W,1'idth Outage."

1R14 volt / Origin/

Location Tube#

Cal Probe Degrees Percent Code TSP - Offset Axial Circ Dataset 75 118 104 51OUL 0.93 176 0

INR LTE 9.48 510 Bobbi 75 118 104 510UL 5.65 172 0

DNT LTE 10.44 510 Bobbi 75 122 110 540HF 0.59 9

ID 30 TWD 15S 44.92 540 Bobbi 75 122 110 540HF 3.01 178 0 DNT LTE 9.82 540 Bobbi 75 122 156 520HF 0.00 0

0 CLP UTS

-1.71 0.15 0.23 Spec Int 75 122 156 520HF 0.60 29 0

VOL UTS

-1.71 Spec Int 75 122 156 520HF 0.63 21 0

VOL UTS

-1.56 Spec Int 75 122 156 520HF 0.00 0

0 CLP UTS

-1.56 0.20 0.17 Spec Int 75 123 110 540HF 0.35 10 0

BVC 15S 20.77 540_Bobbi 75 123 167 520HF 0.29 21 0

VOL 15S 21.23 R13DCLP+

75 123 167 520HF 0.00 0

0 CLP 15S 21.23 0.14 0.11 R13DCLP+

75 123 167 520HF 0.18 9

0 VOL 15S 22.66 RI3DCLP+

75 123 167 520HF 0.00 0

0 CLP 15S 22.66 0.14 0.16 R13DCLP+

75 123 110 540HF 0.79 6

ID 20 TWD 15S 24.25 540 Bobbi 75 123 167 520HF 0.00 0

0 CLP 15S 25.16 0.14 0.16 Spec Int 75 123 167 520HF 0.52 19 0 VOL 15S 25.16 Spec Int 75 123 110 540HF 4.00 174 0

DNT 15S 32.25 540 Bobbi 75 123 156 520HF 0.00 0

0 CLP UTS

-27.16 0.15 0.12 R13DCLP+

75 123 156 520HF 0.35 11 0 VOL UTS

-27.16 R13DCLP+

75 123 156 520HF 0.00 0

0 CLP UTS

-25.63 0.15 0.12 R13DCLP+

75 123 156 520HF 0.28 11 0

VOL UTS

-25.63 RI3DCLP+

75 123 156 520HF 0.00 0

0 NDF UTS

-24.44 R13DCLP+

75 123 156 520HF 0.00 0

0 CLP UTS

-23.16 0.15 0.17 Spec lnt 75 123 156 520HF 0.59 8

0 VOL UTS

-23.16 Spec lnt 75 123 156 520HF 0.00 0

0 NDF UTS

-22.12 Spec Int 75 124 104 51OUL 0.00 0

0 ROB LTE 0.00 510 Bobbi 75 124 84 51OUL 0.00 0

0 ROB LTS

-17.20 Sludge 75 124 84 51OUL 0.00 0

0 ROB LTS

-17.20 510 Bobbi 75 124 94 51OUL 0.00 0

0 ROB LTS

-15.61 510 Bobbi 75 124 94 51OUL 0.00 0

0 ROB LTS

-15.00 Sludge 75 125 104 51OUL 6.09 175 0 DNT LTE 11.11 510_Bobbi 76 68 1

510UL 5.13 163 0

DNT LTS 0.00 510 Bobbi 76 69 2

51OUL 23.45 168 0

DNT LTS

-0.71 510 Bobbi 76 70 1

51OUL 10.93 168 0

DNT LTS 0.00 510_Bobbi 76 76 33 51OUL 6.35 165 0 DNT LTS 0.00 510 Bobbi Page 90 of 325

TR-151, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A Site:

Three Mile Island Al Inhdicaions. With Length and Width Outage.

1R14 Volt / Origin/

Location Tube#

Cal Probe Degrees Percent Code TSP - Offset Axial Circ Dataset 76 77 34 51OUL 3.35 163 0 DNT LTS 0.02 510_Bobbi 76 81 34 51OUL 2.61 160 0

DNT LTS 0.00 510 Bobbi 76 82 33 51OUL 3.04 165 0

DNT LTS 0.00 510_Bobbi 76 90 153 520HF 0.00 0

0 NDF 15S 5.57 Spec -nt 76 90 39 51OUL 0.11 83 0 NQI 15S 5.57 510 Bobbi 76 90 153 520HF 0.00 0

0 NDF 15S 16.80 Spec Int 76 90 39 51OUL 0.21 109 0 NQI 15S 16.80 510_Bobbi 76 100 39 51OUL 0.29 111 0 NQI 08S 22.98 510 Bobbi 76 100 153 520HF 0.00 0

0 NDF 09S

-16.02 SpecInt 76 108 1

51OUL 0.21 84 0 NQI LTE 11.44 510 Bobbi 76 108 154 520HF 0.00 0

0 NDF LTS

-12.66 SpecInt 76 116 1

5101UL 5.16 171 0

DNT LTE 10.66 510_Bobbi 76 123 2

51OUL 4.52 174 0

DNT LTE 11.00 510_Bobbi 77 32 128 51OUL 6.09 174 0

DNT LTE 6.60 510 Bobbi 77 33 128 51OUL 7.03 175 0

DNT LTE 6.28 510 Bobbi 77 37 109 540HF 0.60 106 OD 17 TWD 07S

-0.81 540 Bobbi 77 37 38 520HF 0.00 0

0 CLP ETL 1.16 0.09 0.12 KEXP_+Pt 77 37 38 520HF 0.15 12 ID 13 VOL ETL 1.16 KEXP +Pt 77 37 38 520HF 0.00 0

0 CLP ETL 3.12 0.13 0.18 KEXP +Pt 77 37 38 520HF 0.53 20 ID 33 VOL ETL 3.12 KEXP +Pt 77 37 38 520HF 0.38 15 ID 20 VOL ETL 3.55 KEXP +Pt 77 37 38 520HF 0.00 0

0 CLP ETL 3.55 0.13 0.18 KEXP +Pt 77 37 38 520HF 0.00 0

0 CLP ETL 4.86 0.13 0.18 KEXP +Pt 77 37 38 520HF 0.51 25 ID 51 VOL ETL 4.86 KEXP +Pt 77 37 150 520HF 0.00 0

0 NDF UTS 0.00 Spec Int 77 37 109 540HF 2.75 177 0

DNT UTS 0.00 540_Bobbi 77 38 55 51OUL 2.35 177 0

INR UTS 0.00 510_Bobbi 77 40 122 520HF 0.00 0

0 NDF UTS

-0.04 Spec_ nt 77 40 54 51OUL 2.60 181 0

DNT UTS

-0.04 510_Bobbi 77 41 55 510UL 2.56 176 0 DNT UTS 0.00 510 Bobbi 77 41 122 520HF 0.00 0

0 NDF UTS 0.00 Spec mnt 77 43 55 51OUL 2.64 178 0 DNT UTS 0.04 510 Bobbi Page 91 of 325

TR-151, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A Site:

Three Mile Island A"U/

Indications, With Length and WI'dih Outage:

lR14 T,'olt / Origin!

Location Tube#

Cal Probe Degrees Percent Code TSP - Offset Axial Circ Dataset 77 43 122 520HF 0.00 0

0 NDF UTS 0.04 SpecInt 77 44 86 520HF 0.27 16 0

VOL ETL

-0.90 KEXP +Pt 77 44 86 520HF 0.00 0

0 CLP ETL

-0.90 0.19 0.17 KEXP +Pt 77 44 122 520HF 0.00 0

0 NDF UTS 0.02 Spec Int 77 44 97 51OUL 3.20 175 0 DNT UTS 0.02 510 Bobbi 77 44 122 520HF 0.33 18 0

PRA UTS 6.38 SpecInt 77 45 97 51OUL 3.08 174 0

DNT UTS 0.06 510 Bobbi 77 45 150 520HF 0.00 0

0 NDF UTS 0.06 SpecInt 77 47 90 520HF 0.00 0

0 CLP ETL

-6.88 0.14 0.17 R13DCLP+

77 47 90 520HF 0.58 31 0 VOL ETL

-6.88 R13DCLP+

77 47 90 520HF 0.00 0

0 CLP ETL

-6.51 0.14 0.17 R13DCLP+

77 47 90 520HF 1.07 24 0 VOL ETL

-6.51 R13DCLP+

77 47 90 520HF 0.40 24 0 VOL ETL

-6.06 R13DCLP+

77 47 90 520HF 0.00 0

0 CLP ETL

-6.06 0.14 0.17 R13DCLP+

77 47 97 51OUL 3.34 176 0

DNT UTS 0.06 510 Bobbi 77 48 86 520HF 0.33 28 0

VOL ETL

-0.43 KEXP +Pt 77 48 86 520HF 0.00 0

0 CLP ETL

-0.43 0.10 0.17 KEXP +Pt 77 48 122 520HF 0.00 0

0 NDF UTS 0.04 Spec Int 77 48 97 51OUL 2.61 175 0

DNT UTS 0.04 510 Bobbi 77 49 150 520HF 0.00 0

0 NDF UTS 0.02 SpecInt 77 49 97 51OUL 2.80 175 0

DNT UTS 0.02 510_Bobbi 77 50 86 520HF 0.00 0

0 CLP ETL 0.05 0.14 0.17 KEXP +Pt 77 50 86 520HF 0.54 27 ID 58 VOL ETL 0.05 KEXP +Pt 77 50 97 51OUL 2.99 174 0

DNT UTS 0.02 510 Bobbi 77 50 150 520HF 0.00 0

0 NDF UTS 0.02 Spec Int 77 51 122 520HF 0.00 0

0 NDF UTS 0.06 Spec Int 77 51 97 51OUL 4.24 172 0 DNT UTS 0.06 510_Bobbi 77 53 97 510UL 3.85 174 0

DNT UTS 0.02 510 Bobbi 77 53 122 520HF 0.00 0

0 NDF UTS 0.02 SpecInt 77 54 86 520HF 0.41 24 0

VOL ETL

-0.12 KEXP_+Pt 77 54 86 520HF 0.00 0

0 CLP ETL

-0.12 0.14 0.17 KEXP +Pt 77 54 86 520HF 1.06 31 ID 76 VOL ETL 0.42 KEXP +Pt 77 54 86 520HF 0.00 0

0 CLP ETL 0.42 0.19 0.17 KEXP_+Pt 77 54 86 520HF 0.61 21 ID 36 VOL ETL 1.07 KEXP +Pt 77 54 86 520HF 0.00 0

0 CLP ETL 1.07 0.14 0.17 KEXP +Pt Page 92 of 325

TR-151, Revision 0 Appendix II Recordable Indications Componentf:

TMI-OTSG-A Site:

Three Mile Island All J;Tdicat ions, W' 'ith Length and JJ, lidth Outage:

1R14 1'olt / Origin' Degrees Percent 0.00 0

0 1.76 33 ID 86 4.58 170 0

0.00 0

0 3.40 172 0.00 0

Cal Tube#

77 54 86 77 54 86 77 54 97 77 54 122 77 55 97 77 55 150 Probe 520HF 520HF 51OUL 520HF 51OUL 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 520HF 540HF 540HF 51OUL 520HF 520HF 51 OUL 520HF 51OUL 520HF 510UL 520HF 540HF 51OUL 520HF 520HF 540HF 3.93 173 0.00 0

0.00 0

3.17 179 0.00 0

3.60 179 0.00 0

3.31 178 0.00 0

3.08 180 3.63 177 0.00 0

0.00 0

3.53 176 Code CLP VOL DNT NDF Location TSP - Offset ETL 2.32 ETL 2.32 UTS 0.04 UTS 0.04 0

DNT UTS 0

NDF UTS CLP VOL CLP VOL VOL CLP VOL CLP CLP VOL CLP VOL NDF DNT TWD ETL ETL ETL ETL ETL ETL ETL ETL ETL ETL ETL ETL UTS UTS UTS 0

DNT UTS 0

NDF UTS 0

NDF UTS 0

DNT UTS 0

0 NDF UTS DNT UTS 0

NDF UTS 0

DNT UTS 0 NDF UTS 0

DNT UTS 0

DNT UTS 0 NDF UTS 0

NDF UTS 0

DNT UTS 0.02 0.02

-2.38

-2.38

-1.26

-1.26 0.40 0.40 3.73 3.73 5.00 5.00 5.37 5.37 0.00 0.00 5.99 0.02 0.02 0.08 0.08 0.06 0.06 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Axial Circ Dataset 0.19 0.23 KEXP +Pt KEXP +Pt 510 Bobbi SpecInt 510 Bobbi SpecInt 0.14 0,11 R13DCLP+

R13DCLP+

0.14 0.17 R13DCLP+

R13DCLP+

R13DCLP+

0.14 0.11 R13DCLP+

R13DCLP+

0.14 0.11 R13DCLP+

0.19 0.17 R13DCLP+

R13DCLP+

0.24 0.17 R13DCLP+

R13DCLP+

SpecInt 540 Bobbi 540_Bobbi 510 Bobbi Spec Int Spec mnt 510 Bobbi Specmnt 510 Bobbi Spec int 510_Bobbi SpecInt 540 Bobbi 510 Bobbi SpecInt SpecInt i40 Bobbi Page 93 of 325 0

32 0

20 20 0

11 0

0 20 0

11 0

171 6

0 0

0 0

ID 33 0

ID 11 0

0 ID 33 0

ID 11 0

0 ID 20 77 77 77 77 77 77 77 77 77 77 77 77 77 77 77 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 90 90 90 90 90 90 90 90 90 90 90 90 90 125 125 0.00 0.81 0.00 0.72 0.41 0.00 0.37 0.00 0.00 0.41 0.00 0.52 0.00 3.58 0.41 77 57 97 77 57 122 77 58 28 77 58 1

77 59 28 77 59 1

77 60 28 77 60 2

77 61 28 77 61 7

77 62 1

77 62 28 77 63 28 77 63 7

TR-15 1, Revision 0 Appendix I1 Recordable Indications Comp)o7ent:

TMI-OTSG-A Site:

Three Mile Island

.A11 Indcaiions. With Length and J'Vidth Oulage:

IR14 Volt / Origin!

Location Tube#

Cal Probe Degrees Percent Code TSP - Offset Axial Cire Dataset 77 67 27 520HF 0.23 33 0

VOL ETL

-0.10 KEXP +Pt 77 67 27 520HF 0.00 0

0 CLP ETL

-0.10 0.10 0.17 KEXP_+Pt 77 68 1

51OUL 2.71 164 0

DNT LTS 0.00 510_Bobbi 77 69 2

51OUL 26.56 168 0 DNT LTS 0.06 510_Bobbi 77 70 1

51OUL 21.27 169 0

DNT LTS 0.00 510 Bobbi 77 71 2

51OUL 4.77 170 0 DNT LTS 0.08 510 Bobbi 77 73 61 520HF 0.27 18 ID 27 VOL ETL 0.24 KEXP +Pt 77 73 61 520HF 0.00 0

0 CLP ETL 0.24 0.15 0.12 KEXP +Pt 77 73 61 520HF 0.00 0

0 CLP ETL 0.72 0.10 0.17 KEXP +Pt 77 73 61 520HF 1.55 33 ID 86 VOL ETL 0.72 KEXP +Pt 77 73 61 520HF 0.65 28 ID 63 VOL ETL 1.54 KEXP +Pt 77 73 61 520HF 0.00 0

0 CLP ETL 1.54 0.10 0.17 KEXP +Pt 77 73 61 520HF 0.47 20 ID 33 VOL ETL 4.26 KEXP +Pt 77 73 61 520HF 0.00 0

0 CLP ETL 4.26 0.10 0.12 KEXP_+Pt 77 74 62 520HF 0.00 0

0 CLP ETL

-0.54 0.13 0.18 KEXP_+Pt 77 74 62 520HF 0.26 16 0

VOL ETL

-0.54 KEXP_+Pt 77 74 62 520HF 0.25 16 ID 25 VOL ETL 0.76 KEXP +Pt 77 74 62 520HF 0.00 0

0 CLP ETL 0.76 0.13 0.18 KEXP +Pt 77 74 62 520HF 0.00 0

0 CLP ETL 2.43 0.13 0.18 KEXP +Pt 77 74 62 520HF 0.14 12 ID 17 VOL ETL 2.43 KEXP_+Pt 77 96 61 520HF 0.00 0

0 CLP ETL

-0.85 0.15 0.12 KEXP +Pt 77 96 61 520HF 0.46 19 0

VOL ETL

-0.85 KEXP +Pt 77 96 61 520HF 0.23 19 ID 30 VOL ETL 1.83 KEXP +Pt 77 96 61 520HF 0.00 0

0 CLP ETL 1.83 0.15 0.17 KEXP +Pt 77 96 114 540HF 0.63 10 ID 33 TWD UTS 6.31 540_Bobbi 77117 154 520HF 0.00 0

0 NDF 10S 0.50 Spec Int 77 117 2

51OUL 0.30 108 0 NQI 10S 0.50 510 Bobbi 77 117 2

51OUL 5.19 172 0

DNT LTE 10.51 510_Bobbi 77 119 1

51OUL 7.43 175 0 DNT LTE 10.25 510 Bobbi 77 121 2

51OUL 2.36 168 0

INR LTE 9.60 510 Bobbi 77 121 2

51OUL 0.43 98 0

NQI LTE 14.00 510 Bobbi 77 121 154 520HF 0.00 0

0 NDF LTS

-10.00 SpecInt 77 122 159 540HF 0.65 7

ID 23 TWD 13S 34.59 540_Bobbi 77 122 135 520HF 0.00 0

0 NDF 14S

-1.41 Spec Int Page 94 of 325

TR-151, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A Site:

Three Mile Island All hIndications, W1ith Length and Width Outage:

IR14 Volt / Origin/

Location Tube4 Cal Probe Degrees Percent Code TSP - Offset Axial Circ Dataset 77 122 159 540HF 6.00 176 0

DNT LTE 10.20 540_Bobbi 77 123 1

51OUL 7.33 171 0 DNT LTE 10.73 510 Bobbi 77 124 92 520HF 0.00 0

0 CLP UTS

-0.63 0.22 0.23 R13DCLP+

77 124 92 520HF 2.08 27 0

VOL UTS

-0.63 R13DCLP+

77 126 166 520HF 0.00 0

0 CLP 15S 8.58 0.10 0.15 R13DCLP+

77 126 166 520HF 0.16 9

0 VOL 15S 8.58 R13DCLP+

77 126 166 520HF 0.25 7

0 VOL 15S 10.21 R13DCLP+

77 126 166 520HF 0.00 0

0 CLP 15S 10.21 0.21 0.15 R13DCLP+

77 126 166 520HF 0.11 7

0 VOL 15S 15.50 R13DCLP+

77 126 166 520HF 0.00 0

0 CLP 15S 15.50 0.10 0.10 R13DCLP+

77 126 166 520HF 0.00 0

0 CLP 15S 18.06 0.10 0.15 R13DCLP+

77 126 166 520HF 0.20 12 0 VOL 15S 18.06 R13DCLP+

77 126 166 520HF 0.54 20 0 VOL 15S 18.39 R13DCLP+

77 126 166 520HF 0.00 0

0 CLP 15S 18.39 0.10 0.20 R13DCLP+

77 126 166 520HF 0.13 15 0 VOL 15S 24.01 R13DCLP+

77 126 166 520HF 0.00 0

0 CLP 15S 24.01 0.10 0.15 R13DCLP+

77 126 166 520HF 0.10 21 0

VOL 15S 26.97 R13DCLP+

77 126 166 520HF 0.00 0

0 CLP 15S 26.97 0.10 0.15 R13DCLP+

78 2

91 51OUL 5.01 174 0

DNT LTE 10.44 510 Bobbi 78 4

91 51OUL 0.20 78 0

NQI 11S

-0.82 510 Bobbi 78 4 154 520HF 0.00 0

0 NDF 11S

-0.82 SpecInt 78 30 87 51OUL 3.24 169 0

DNT UTS 0.00 510 Bobbi 78 33 37 520HF 0.00 0

0 CLP ETL 2.88 0.15 0.17 KEXP_+Pt 78 33 37 520HF 0.13 25 ID 49 VOL ETL 2.88 KEXP_+Pt 78 33 37 520HF 0.00 43 0

ARC ETL 3.17 0.23 KEXP +Pt 78 33 37 520HF 1.93 34 ID 78 SCI ETL 3.17 KEXP +Pt 78 33 37 520HF 0.25 19 ID 32 VOL ETL 4.54 KEXP +Pt 78 33 37 520HF 0.00 0

0 CLP ETL 4.54 0.10 0.17 KEXP +Pt 78 33 37 520HF 0.17 20 ID 35 VOL ETL 5.17 KEXP +Pt 78 33 37 520HF 0.00 0

0 CLP ETL 5.17 0.15 0.17 KEXP +Pt 78 33 97 51OUL 7.42 178 0

DNT LTE 6.98 510 Bobbi 78 33 97 51OUL 2.90 173 0

DNT UTS 0.02 510 Bobbi 78 34 97 510UL 0.27 82 OD 6

TWD 10S

-0.84 510 Bobbi 78 34 97 510UL 3.28 167 0

DNT UTS

-0.02 510 Bobbi 78 35 109 540HF 3.25 173 0

DNT UTS 0.02 540 Bobbi Page 95 of 325

TR-151, Revision 0 Appendix II Recordable indications Component:

TMI-OTSG-A Site:

Three Mile Island All ndicutions. Hith Length and 1,i'idth Ottage:

1R14 Volt / Origin/

Location Tube#

Cal Probe Degrees Percent Code TSP - Offset Axial Circ Dataset 78 37 122 520HF 0.00 0

0 NDF UTS 0.00 Spec Int 78 37 97 51OUL 2.88 168 0

DNT UTS 0.00 510 Bobbi 78 39 122 520HF 0.00 0

0 NDF UTS

-0.02 Spec Int 78 39 97 51OUL 2.98 166 0

DNT UTS

-0.02 510 Bobbi 78 40 150 520HF 0.00 0

0 NDF UTS 0.00 Spec -nt 78 40 97 51OUL 2.97 168 0

DNT UTS 0.00 510 Bobbi 78 41 122 520HF 0.00 0

0 NDF UTS

-0.02 SpecInt 78 41 97 51OUL 2.77 168 0

DNT UTS

-0.02 510_Bobbi 78 42 97 51OUL 2.74 169 0

DNT UTS

-0.02 510 Bobbi 78 42 122 520HF 0.00 0

0 NDF UTS

-0.02 SpecInt 78 43 122 51OUL 2.80 174 0 DNT UTS 0.02 510 Bobbi 78 43 122 520HF 0.00 0

0 NDF UTS 0.02 SpecInt 78 44 122 520HF 0.00 0

0 NDF UTS

-0.04 SpecInt 78 44 97 51OUL 2.64 172 0

DNT UTS

-0.04 510_Bobbi 78 45 122 520HF 0.00 0

0 NDF UTS 0.02 SpecInt 78 45 97 51OUL 3.03 173 0

DNT UTS 0.02 510 Bobbi 78 46 122 520HF 0.00 0

0 RPP ETL

-1.00 5.40 SpecInt 78 46 132 520HF 0.00 0

0 RBD ETL

-1.00 5.40 Spec nt 78 46 176 520HF 0.43 21 ID 36 VOL ETL 0.52 Spec Int 78 46 176 520HF 0.00 0

0 CLP ETL 0.52 0.13 0.11 Spec Int 78 46 176 520HF 0.00 0

0 CLP ETL 1.05 0.13 0.17 Spec Int 78 46 176 520HF 0.67 24 ID 47 VOL ETL 1.05 Spec -nt 78 46 176 520HF 0.17 25 ID 89 VOL ETL 1.78 Spec Int 78 46 176 520HF 0.00 0

0 CLP ETL 1.78 0.13 0.11 Spec Int 78 46 176 520HF 0.23 16 ID 22 VOL ETL 3.54 Spec.. Int 78 46 176 520HF 0.00 0

0 CLP ETL 3.54 0.13 0.11 Spec Int 78 46 176 520HF 0.26 22 ID 40 VOL ETL 5.39 Spec.Int 78 46 176 520HF 0.00 0

0 CLP ETL 5.39 0.13 0.17 Spec Int 78 46 97 51OUL 2.95 171 0

DNT UTS 0.00 510 Bobbi 78 46 122 520HF 0.00 0

0 NDF UTS 0.00 SpecInt 78 47 122 520HF 0.00 0

0 NDF UTS 0.00 SpeclInt 78 47 97 51OUL 3.22 170 0

DNT UTS 0.00 510 Bobbi 78 47 122 520HF 0.00 0

0 CLP UTS 3.12 0.09 0.11 Spec mnt 78 47 122 520HF 0.43 20 0

VOL UTS 3.12 Spec jnt 78 47 122 520HF 0.34 30 0

VOL UTS 6.41 Spec lnt Page 96 of 325

TR-151, Revision 0 Appendix 11 Recordable Indications Component:

TMI-OTSG-A Site:

Three Mile Island All Inclications, WIith Length and Width Outage:

!R14 Volt / Origin!

Location Tube#

Cal Probe Degrees Percent Code TSP - Offset Axial Circ Dataset 78 47 122 520HF 0.00 0

0 CLP UTS 6.41 0.09 0.11 SpecInt 78 48 122 520HF 0.00 0

0 NDF UTS 0.00 SpecInt 78 48 97 51OUL 3.05 170 0

DNT UTS 0.00 510_Bobbi 78 51 122 520HF 0.00 0

0 NDF UTS 0.02 SpecInt 78 51 97 51OUL 3.83 167 0

DNT UTS 0.02 510_Bobbi 78 52 97 51OUL 2.56 174 0

DNT UTS

-0.04 510 Bobbi 78 52 122 520HF 0.00 0

0 NDF UTS

-0.04 SpecInt 78 53 150 520HF 0.00 0

0 NDF UTS

-0.02 Spec Int 78 53 97 51OUL 3.47 170 0

DNT UTS

-0.02 510_Bobbi 78 54 97 51OUL 3.39 172 0 DNT UTS

-0.02 510 Bobbi 78 54 150 520HF 0.00 0

0 NDF UTS

-0.02 SpecInt 78 55 122 520HF 0.00 0

0 NDF UTS 0.00 Spec Int 78 55 97 51OUL 3.22 170 0 DNT UTS 0.00 510 Bobbi 78 57 28 520HF 0.00 0

0 NDF UTS 0.00 SpecInt 78 57 1

51OUL 3.20 176 0

DNT UTS 0.00 510 Bobbi 78 58 31 520HF 0.36 33 0

VOL ETL

-1.83 R13DCLP+

78 58 31 520HF 0.00 0

0 CLP ETL

-1.83 0.18 0.19 R13DCLP+

78 58 31 520HF 0.23 23 ID 43 VOL ETL 1.32 R13DCLP+

78 58 31 520HF 0.00 0

0 CLP ETL 1.32 0.18 0.14 R13DCLP+

78 58 31 520HF 0.47 19 0

INR ETL 5.01 RI3DCLP+

78 58 7

540HF 2.65 176 0

DNT UTS 0.00 540 Bobbi 78 58 28 520HF 0.00 0

0 NDF UTS 0.00 SpecInt 78 58 7

540HF 0.48 4

0 INR UTS 5.41 540 Bobbi 78 58 28 520HF 0.00 0

0 RIC UTS 5.58 R13DCLP+

78 60 28 520HF 0.00 0

0 NDF UTS 0.00 Spec -nt 78 60 1

51OUL 2.89 172 0

DNT UTS 0.00 510 Bobbi 78 61 28 520HF 0.00 0

0 NDF UTS 0.06 SpecInt 78 61 2

51OUL 2.70 175 0

DNT UTS 0.06 510 Bobbi 78 64 41 520HF 0.00 0

0 NDF 05S

-0.67 Spec Int 78 64 1

51OUL 0.22 78 0 NQI 05S

-0.67 510 Bobbi 78 64 28 520HF 0.00 0

0 RIC 05S

-0.67 Spec_-it 78 68 7

540HF 0.61 3

0 INR 04S 28.28 540 Bobbi Page 97 of 325

TR-151, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A Site:

Three Mile Island All hIclicaions, H 'ith Length and 'k1idth Outage:

1R!4 Tube#

Cal Probe 78 69 1

78 70 2

78 71 1

78 90 124 78 90 124 78 90 114 78 90 124 78 90 124 78 92 61 78 92 61 78 117 1

78 117 154 78 118 2

78 119 1

" 78 121 1

78 122 2

78 125 1

78 125 1

78 125 1

79 2

91 79 2

91 79 20 30 79 20 30 79 20 30 79 20 30 79 20 107 79 20 155 79 20 155 79 20 155 79 20 107 79 22 87 79 23 152 51OUL 51OUL 51OUL 520HF 520HF 540HF 520HF 520HF 520HF 520HF 51OUL 520HF 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51 OUL 51 OUL 520HF 520HF 520HF 520HF 540HF 520HF 520HF 5201iF 540HF 510UL 520HF Volt/

Origin' Degrees Percent 18.01 16.38 8.71 0.63 0.00 0.45 0.63 0.00 0.00 0.54 0.26 0.00 5.78 7.60 3.12 5.93 0.24 0.33 3.66 6.41 4.07 0.00 0.23 0.00 0.37 0.31 0.00 0.37 0.22 0.32 2.26 0.15 169 168 168 16 0

4 4

0 0

21 96 0

174 174 172 173 137 102 174 173 172 0

17 0

24 16 0

24 21 11 174 18 0

0 0

ID 25 0

0 0

0 0

0 0

0 0

0 0

0 OD 2

0 0

0 0

0 0

0 ID 47 0

0 0

0 0

0 0

Location Code TSP - Offset DNT LTS 0.00 DNT LTS 0.08 DNT LTS 0.00 VOL ETL 0.48 CLP ETL 0.48 INR UTS 5.20 VOL UTS 5.26 CLP UTS 5.26 CLP ETL

-0.21 VOL ETL

-0.21 NQI LTE 7.00 NDF LTS

-17.00 DNT LTE 10.66 DNT LTE 10.29 DNT LTE 8.70 DNT LTE 10.63 TWD 11S 0.57 INR 15S

-0.07 DNT LTE 9.72 DNT LTE 5.40 DNT LTE 10.15 CLP ETL

-0.72 VOL ETL

-0.72 CLP ETL 2.36 VOL ETL 2.36 BVC UTS 5.11 CLP UTS 5.60 VOL UTS 5.60 PRA UTS 6.28 BVC UTS 6.42 INR LTE 10.44 VOL UTS 0.66 Axial Circ Dataset 510 Bobbi 510_Bobbi 510 Bobbi R13DCLP+

0.14 0.17 R13DCLP+

540 Bobbi R13DCLP+

0.18 0.17 R13DCLP+

0.10 0.12 KEXP_+Pt KEXP_+Pt 510 Bobbi SpecInt 510_Bobbi 510_Bobbi 510_Bobbi 510_Bobbi 510 Bobbi 510 Bobbi 510 Bobbi 510 Bobbi 510 Bobbi 0.09 0.18 KEXP +Pt KEXP +Pt 0.09 0.18 KEXP +Pt KEXP +Pt 540 Bobbi 0.14 0.16 SIvBdr +Pt SlvBdr +Pt SlvBdr +Pt 540 Bobbi 510 Bobbi SIvBdr +Pt Page 98 of 325

TR-151, Revision 0 Appendix II Recordable Indications Component:

TMI-OTSG-A Site.

Three Mile Island All Indications. JW'ith Length and Wi"dth Outagze:

!R!4 Volt / Origin/

Location Tube#

Cal Probe Degrees Percent Code TSP - Offset Axial Circ Dataset 79 23 152 520HF 0.00 90 0

CLP UTS 0.66 0.19 0.10 SlvBdr_+Pt 79 24 90 520HF 0.30 20 0

VOL ETL

-5.38 KEXP +Pt 79 24 90 520HF 0.00 0

0 CLP ETL

-5.38 0.19 0.17 KEXP +Pt 79 24 30 520HF 0.00 0

0 CLP ETL 3.18 0.13 0.18 KEXP +Pt 79 24 30 520HF 0.27 15 ID 20 VOL ETL 3.18 KEXP +Pt 79 24 30 520HF 0.00 0

0 CLP ETL 4.53 0.09 0.18 KEXP +Pt 79 24 30 520HF 0.49 15 ID 20 VOL ETL 4.53 KEXP +Pt 79 24 107 540HF 0.36 7

0 BVC UTS 1.97 540 Bobbi 79 24 152 520HF 0.47 19 0

VOL UTS 2.14 SlvBdr_+Pt 79 24 152 520HF 0.00 0

0 CLP UTS 2.14 0.14 0.21 SlvBdr_+Pt 79 25 29 520HF 0.00 0

0 CLP ETL 0.18 0.10 0.17 KEXP_+Pt 79 25 29 520HF 0.36 17 ID 25 VOL ETL 0.18 KEXP +Pt 79 25 29 520HF 0.00 0

0 CLP ETL 3.70 0.10 0.11 KEXP +Pt 79 25 29 520HF 0.19 13 ID 15 VOL ETL 3.70 KEXP +Pt 79 25 29 520HF 0.16 19 ID 30 VOL ETL 5.07 KEXP +Pt 79 25 29 520HF 0.00 0

0 CLP ETL 5.07 0.10 0.11 KEXP +Pt 79 25 87 51OUL 2.68 168 0

DNT UTS 0.00 510_Bobbi 79 26 90 520HF 0.00 0

0 CLP ETL

-2.30 0.14 0.17 SpecInt 79 26 90 520HF 1.15 30 0

VOL ETL

-2.30 SpecInt 79 26 107 540HF 0.41 10 ID 33 TWD UTS 4.85 540 Bobbi 79 26 152 520HF 0.95 22 0

VOL UTS 5.21 SlvBdr_+Pt 79 26 152 520HF 0.00 0

0 CLP UTS 5.21 0.14 0.15 SlvBdr_+Pt 79 27 88 51OUL 2.51 172 0

DNT UTS 0.02 510_Bobbi 79 28 87 51OUL 2.48 169 0

INR UTS 0.00 510 Bobbi 79 29 29 520HF 0.00 0

0 CLP ETL 2.79 0.10 0.17 KEXP +Pt 79 29 29 520HF 0.96 29 ID 67 VOL ETL 2.79 KEXP +Pt 79 29 152 520HF 0.00 0

0 CLP UTS 0.65 0.14 0.15 SlvBdr +Pt 79 29 152 520HF 0.33 10 0

VOL UTS 0.65 SlvBdr +Pt 79 29 152 5201F 0.46 18 0

VOL UTS 3.06 SlvBdr +Pt 79 29 152 520HF 0.00 0

0 CLP UTS 3.06 0.14 0.15 SlvBdr_+Pt 79 30 87 51OUL 2.36 169 0

INR UTS 0.00 510 Bobbi 79 32 150 520HF 0.60 116 OD 7 TWD 13S

-0.72 Spec lnt 79 32 97 51OUL 0.22 80 0 NQI 13S

-0.72 510 Bobbi 79 32 97 51OUL 7.37 177 0

DNT LTE 7.14 510 Bobbi 79 32 97 51OUL 3.28 169 0

DNT UTS 0.00 510 Bobbi 79 32 122 520HF 0.00 0

0 NDF UTS 0.00 SpecInt Page 99 of 325