EOC-19 Refueling Outage, December 2001 Steam Generator Inservice Inspection - Three-Month Report
ML020720661
Person / Time
Site: Oconee 
Issue date: 03/04/2002
From: Mccollum W
Duke Energy Corp
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML020720661 (176)


Text

Duke Duke Energy rM Energyt Oconee Nuclear Station 7800 Rochester Highway Seneca, SC 29672 W R. McCollum, Jr.

(864) 885-3107 OFFICE Vice President (864) 885-3564 FAX March 4, 2002 U. S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555

Subject:

Duke Power Company, Oconee Nuclear Station, Unit 3 Docket Number 50-270 EOC-1 9 Refueling Outage, December 2001 Steam Generator Inservice Inspection - Three-Month Report As required by Technical Specification 5.6.8.b, the results of the Steam Generator Tube Inservice Inspection performed during the Unit 3 End of Cycle 19 refueling outage are submitted as Attachment A for your review.

Enclosure B provides a supplemental Inspection Assessment we believe will be helpful in reviewing the overall results of our steam generator inspections. Enclosure B also provides a summary of estimated primary-to-secondary leakage from the SGs in their as-found condition following a postulated Loss of Coolant Accident. This summary is required by License Condition 6 described in NRC letter to Duke Energy Corporation, dated December 15, 2000.

Enclosure C provides a copy of the steam generator tube inservice inspection summary report provided to the NRC per American Society of Mechanical Engineers Boiler and Pressure Vessel Code, Section Xl, Article IWA-6230 for the subject refueling outage.

If there are any questions you may contact R. C. Douglas at (864) 885-3073.

Very truly yours, W. R. McCollum, Jr. 7 Site Vice President /

Attachments A7~

U. S. Nuclear Regulatory Commission Page 2 March 4, 2002 xc w/attachments:

Mr. Luis A. Reyes Regional Administrator, Region 11 xc w/o attachments:

Mr. M. C. Shannon NRC Senior Resident Inspector Mr. L. E. Qishan ONRR, Senior Project Manager Mr. Virgil R. Autry DHEC

U. S. Nuclear Regulatory Commission Page 1 March 4, 2002 Attachment A Unit 3 End of Cycle 19 Steam Generator Inservice Inspection Steam Generator Three Month Report

1.

The following number of tubes were inspected from the inlet or outlet of the steam generators:

Steam Generator Quantity Inspection Method A

14,854 Bobbin A

14,854 MRPC B

14,845 Bobbin B

14,845 MRPC

2.

The following information is submitted concerning tube indications of imperfections.

(The attached lists identify the tubes with imperfections, their locations, and their size.)

Steam Generator Attachment Inspection Method A

A-1 Bobbin B

A-2 Bobbin A

A-3 MRPC/Plus Point B

A-4 MRPC/Plus Point

3.

The following quantities of tubes were removed from service by plugging. (The tubes are identified in the attachments.)

Number of Tubes Steam Generator Removed from Service Attachment A

165 for Eddy Current indications A-5 62 to capture non-stabilized plugged tube locations A-6 B

81 for Eddy Current indications A-7 48 to capture non-stabilized plugged tube locations A-8

U. S. Nuclear Regulatory Commission Page 2 March 4, 2002

4.

The following number of tubes were repaired in the upper tube sheet by rerolling.

(The tubes are identified in the attachments):

Number of Tubes Steam Generator Repaired by Rerolling Attachment A

  • 12 A-9 B
    • 14 A-10 11 of these remain in service, one was plugged.

13 of these remain in service, one was plugged.

5.

No tubes were repaired by sleeving during this outage.

Summary of Attachments Attachment Number Steam Generator Description A-1 S/G A Bobbin A-2 S/G B Bobbin A-3 S/G A MRPC and Plus Point A-4 S/G B MRPC and Plus Point A-5 S/G A Plugged Tubes A-6 S/G B Plugged Tubes A-7 S/G A Plugged Tubes A-8 S/G B Plugged Tubes A-9 S/G A Rerolled Tubes A-10 S/G B Rerolled Tubes

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:14:54 Component: S/G A Page 1 of 56 ATTACHMENT #1 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW TUBE VOLTS 1

1 24.34 59.81 0.70 1

3 17.46 2.27 1

5 13.06 0.61 8.56 2.33 1

9 0.41 1

13 8.90 1

15 0.31 2

1 1.30 0.84 0.47 0.55 0.50 0.48 0.77 0.65 2

2 0.65 2

3 26.83 21.06 21.56 2

6 0.34 2

7 13.81 24.14 0.31 2

9 0.59 2

11 13.05 2.99 3.82 2

14 0.36 0.37 2

15 0.60 2

17 10.40 2

19 1.20 2

21 0.37 2

24 10.51 2

25 15.33 3

3 6.12 1.37 3

4 25.50 1.33 3

5 33.62 17.42 0.73 0.69 3

6 0.93 0.92 0.35 2.65 3

7 9.21 42.41 17.97 14.74 3

9 0.79 3

10 23.77 5.54 3

13 0.48 3

14 3.01 0.29 3

24 0.56 3

25 0.52 3

27 1.21 3

29 0.82 3

30 0.69 4

4 17.44 13.40 4

8 25.76 0.42 4

10 18.26 7.39 4

16 0.48 4

28 0.45 DEG 189 185 93 180 75 189 99 179 47 114 188 105 117 116 96 93 75 74 92 105 132 180 185 180 112 183 183 100 93 9

59 14 72 122 103 186 99 93 187 191 187 87 183 63 182 183 130 103 64 83 80 129 66 183 177 182 84 179 110 98 103 103 72 91 58 71 101 187 178 182 86 180 194 115 106 CHN P 1 P 1 3

P 1 6

P 1 3

P 1 6

3 P 1 3

3 3

3 3

3 3

3 3

3 P 1 P 1 3

3 P 1 P 1 P 1 6

P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 6

P 1 6

P 1 P 1 3

3 6

6 3

3 6

P 1 P 1 3

P 1 P 1 3

P 1 P 1 P 1 P 1 P 1 3

P 1 P 1 i 1 31 9 1 3

9 1 9 1 3

3 IND DNT DNT NQI DNT ADI DNT NQI DNT ADI NQI DNT NQI NQI TWD NQI NQI NQI NQI NQI NQI NQI DNT DNT DNT NQI DNT DNT NQI NQI DNT ADI NQI NQI NQI NQI DNT NQI NQI DNT DNT DNT ADI DNT ADI DNT DNT NQI NQI ADI ADI NQI NQI ADI DNT DNT DNT NQI DNT NQI NQI NQI NQI NQI NQI NQI NQI NQI DNT DNT DNT NQI DNT DNT NQI NQI

%TW LOCATION 015

-0.29 015

+0.51 013

+4.14 015

-0.44 014

+31.55 UTS

-0.02 015

+1.37 015

+0.73 014

+31.85 010

+4.86 UTS

+0.00 011

+3.62 014

+29.04 6

013

+4.96 011

+18.43 011

+17.89 011

+17.39 012

+8.64 012

+8.13 011

+25.28 013

+5.48 015

+0.40 015

-0.40 LTE

+10.49 007

+14.43 015

+0.51 015

-0.64 014

-0.35 015

-0.40 UTS

-0.15 015

+32.69 015

+0.79 011

+0.55 013

+0.75 010

+0.60 UTS

-0.02 010

+0.44 010

-0.29 UTS

+0.00 UTS

+0.02 015

+0.64 013

+4.56 015

-0.35 014

+30.43 015

+0.53 015

-0.64 011

+5.76 TO+22.08 013

+6.41 014

+31.61 010

+20.47 TO+26.60 003

+15.68 015

-1.13 015

+26.05 TO+35.97 015

-0.51 015

+0.55 LTE

+11.08 015

-1.19 015

-0.58 015

-1.22 013

-0.51 015

+0.71 014

+0.27 010

+0.51 010

+0.38 003

+3.46 011

-0.79 011

-0.80 UTS

+0.07 015

+0.73 015

-0.55 011

+6.49 015

+0.59 015

-0.60 LTS

+9.43 009

+16.76 EXT EXT UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTIL 1 UTIL 2 CAL #

69 69 69 69 69 68 68 68 68 72 72 73 69 69 69 69 69 69 69 69 68 98 98 98 69 68 68 68 68 68 68 68 68 68 72 72 72 72 73 73 69 69 69 69 68 68 68 68 69 69 69 69 68 68 68 68 69 68 68 69 68 68 72 73 73 73 72 69 69 68 68 69 69 69 72 LEG OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET PROBE 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 510UL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 510UL 510UL 51OUL 51OUL 51OUL 51OUL 51OUL S5OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 5lOUL 51OUL 51OUL 51OUL 51OUL 51OUL 510UL 51OUL 510UL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 510UL 51OUL 51OUL 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:14:54 Component: S/G A Page 2 of 56 ATTACHMENT #1 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW TUBE VOLTS 4

31 0.50 4

37 0.41 4

38 13.23 1.30 4

39 12.58 0.71 5

5 0.75 0.56 0.55 5

8 17.19 0.71 0.59 5

9 0.52 0.45 0.34 1.01 5

11 0.54 5

13 0.75 5

32 6.58 5

42 0.40 5

44 0.93 6

4 0.38 6

5 0.61 6

9 0.44 6

10 0.41 6

11 0.46 6

13 0.65 6

14 0.36 0.38 6

22 0.62

0. 65 6

33 0.95 6

35 0.70 6

39 0.45 6

41 0.35 6

49 10.08 6

50 18.23 6.75 6.96 7

7 0.49 7

10 0.99 7

12 0.61 7

13 0.36 7

16 0.41 7

18 22.55 16.65 7

19 0.76 7

20 0.46 7

23 0.52 7

34 0.33 7

45 0.64 7

48 0.55 7

50 0.28 7

51 11.37 7

52 0.56 8

6 0.37 8

7 0.35 8

8 0.80 8

9 0.98 8

11 0.63 0.43 8

12 0.17 8

14 0.67 8

20 0.41 8

27 0.33 8

37 0.26 8

42 0.86 8

49 0.55 0.46 8

50 0.70 9

8 0.58 9

9 0.76 9

10 0.84 9

11 0.66 9

13 0.99 DEG 62 87 190 39 187 74 108 106 67 193 104 99 115 104 71 112 105 128 183 100 90 103 117 71 98 100 107 125 99 92 133 127 103 102 74 187 18 26 195 87 115 55 92 105 176 178 106 109 120 75 111 107 59 185 115 102 118 96 134 91 58 54 115 103 110 87 116 123 105 54 96 113 96 108 98 CH P

3 P

P P

p 3

3 p

P 3

3 3

P P

3 3

3 3

3 P

3 3

P 3

P 3

3 3

P P

P P

3 3

P P

P P

P P

3 3

3 3

3 P

P P

3 P

3 P

P P

p 3

P P

P P

3 3

P 3

3 P

P P

P 3

3 3

3 3

.N IND 1 NQI NQI 1 DNT 1 NQI 1 DNT 2 NQI NQI NQI 1 NQI 1 DNT TWD NQI NQI 1 NQI 1 NQI NQI NQI NQI DNT NQI 1 NQI NQI NQI 1 NQI NQI 1 NQI NQI NQI NQI 1 NQI 1 NQI 1 NQI 1 NQI NQI NQI 1 DNT 1 BLG 1 DWI 1 DNT 1 NQI 1 NQI NQI NQI NQI DNT DNT 1 NQI 1 NQI 1 NQI NQI 1 NQI NQI 1 NQI 1 DNT 1 NQI 1 NQI NQI 1 NQI 1 NQI 1 NQI 1 NQI NQI NQI 1 NQI NQI NQI 1 NQI 1 NQI 1 NQI 1 NQI NQI NQI NQI NQI NQI

%TW LOCATION 009

+0.22 014

+28.45 UTS

-0.02 015

+0.49 UTS

-0.02 015

+0.51 015

+2.45 014

+32.94 015

+0.93 UTS

+0.02 24 015

+13.30 014

+33.03 015

+13.36 015

-0.51 008

-0.73 014

+33.58 005

+34.78 LTS

+21.57 TO+29.69 LTE

+17.63 003

+35.71 011

-0.80 010

+10.24 010

+8.72 008

-0.73 010

+3.48 008

-0.66 009

+23.18 014

+33.61 014

+28.25 009

+0.36 009

-0.60 009

-0.58 009

+0.31 014

+29.02 014

+29.69 UTS

+0.02 UTS

-0.20 015

+0.78 015

+0.38 008

-0.66 008

-0.66 009

+22.74 TO+29.47 013

+22.80 014

+30.22 UTS

+1.36 UTS

+1.11 009

-0.60 009

-0.69 009

-0.64 014

+32.04 009

-0.69 005

+1.10 005

+0.26 UTS

+0.04 010

+0.46 010

-0.07 007

+21.54 008

+0.00 008

-0.68 008

-0.71 015

+0.42 009

+21.89 TO+26.67 009

+25.46 009

-0.77 014

+1.24 LTS

+16.13 009

-0.64 009

-0.86 009

+0.42 007

+0.64 009

+26.28 009

+24.88 009

+24.11 TO+31.36 009

+17.92 TO+31.87 009

+16.17 TO+33.39 EXT UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE EXT UTIL 1 LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTIL 2 CAL #

73 72 73 73 72 72 68 68 68 69 69 69 68 68 68 68 68 68 73 72 73 68 69 69 68 68 69 68 68 69 69 73 72 72 72 72 73 73 73 68 69 69 68 68 69 69 68 69 68 73 72 73 73 72 73 68 69 68 69 69 69 68 69 69 69 77 76 76 76 77 69 68 69 68 68 LEG OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET PROBE 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL SOUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL SlOUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:14:54 Component: S/G A Page 3 of 56 ATTACHMENT #1 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW TUBE VOLTS 9

16 0.30 9

17 0.33 9

21 0.38 9

29 0.67 9

42 0.41 9

43 0.94 9

54 0.51 9

56 0.32 0.35 9

57 0.48 9

59 0.39 10 1

0.49 10 2

0.56 10 4

0.48 10 12 1.07 0.71 0.55 10 18 0.41 10 19 0.54 1.33 10 20 0.33 0.66 10 44 0.69 10 58 0.54 10 59 0.43 10 60 0.83 10 61 0.47 0.30 0.39 11 1

0.37 11 2

0.17 11 4

0.41 11 5

0.35 11 6

0.24 11 13 0.39 11 15 0.48 11 16 0.59 11 22 0.51 11 27 0.47 11 33 0.55 11 56 0.27 11 59 0.58 11 61 0.68 11 68 0.45 1.11 12 5

0.36 12 12 0.32 12 14 0.64 12 42 0.33 12 57 1.06 12 58 0.78 0.48 0.41 12 60 0.55 12 70 0.58 0.33 12 71 9.55 0.23 13 14 0.39 13 31 0.81 13 36 1.01 13 44 0.64 13 47 0.65 13 55 0.23 13 56 0.34 13 63 0.36 0.31 13 64 0.63 13 65 0.59 13 72 10.15 0.40 0.49 13 73 13.34 0.47 0.67 DEG 82 90 106 102 91 91 94 82 72 86 120 72 123 65 105 104 122 140 137 95 90 96 101 83 101 110 99 110 87 72 102 106 113 99 90 105 120 137 84 122 62 98 110 82 110 99 111 87 103 113 102 78 73 101 115 106 191 106 97 83 93 81 108 112 61 49 108 115 104 20 101 77 196 133 117 CHN 3

3 3

P 1 3

P 1 3

3 3

3 3

P 1 P1 3

3 3

P 1 P 1 P 1 P 1 3

3 P 1 3

3 P 1 3

3 3

P 1 P 1 3

3 P 1 3

3 P 1 P 1 3

3 P 1 3

3 3

P 1 3

3 P 1 3

2 1 P 1 P 1 P 1 3

P 1 3

2 1 P 1 3

P 1 3

9 1 3

3 3

3 3

3 3

P 1 P 1 P 1 P 1 3

3 IND %T1 NQI NQI NQI TWD 7 NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI TWD 20 TWD 22 NQI NQI NQI TWD 13 NQI NQI NQI NQI NQI NQI TWD 30 TWD 7 NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI TWD 22 NQI NQI NQI NQI NQI NQI NQI DNT NQI NQI NQI NQI NQI NQI TWD 2 NQI NQI NQI NQI NQI DNT NQI NQI DNT NQI NQI 9 LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG 009 012 002 014 014 014 009 012 004 009 014 007 008 UTS 015 004 015 008 008 009 013 010 009 009 009 010 012 012 012 008 014 014 014 008 009 009 008 007 009 007 015 009 009 015 015 002 005 015 UTS 007 009 008 008 009 008 014 UTS 015 003 011 004 001 014 008 006 009 010 009 009 UTS 010 012 UTS 010 007

+21. 26

+9.51

+22.48

+1.22

+23. 02

+0. 80

+21.39

+25. 98

+28. 94

+32.41

+1. 63

-0.78

-0.71

-0.75

+36. 26

+17.91

+0. 99

-0.74

-0.74

-0.51

+8.04

+1.15

+0.27

+26. 16

+28.62 TO+35.24

+0.53

+30.83

+33.85

+34.14

-0.77

+0.96

+1.26

+20.10

-0.31

+10.95

+8.58 TO+23.14

-0.77

-0.77

+11.27

+8.21

-0.02

+13.90 TO+36.91

+26.61 TO+37.29

+21.59

+0.47

+15.37

+21.30

+0.44

+6.53

-0.80

+0.58

+0.66

+0.40

+12.46 TO+28.45

-0.60

+31.06

+0.00

-0.07

+4.11

-0.78

+12.57

+0.77

+1.13

+35.68

+14.34

+17.16 TO+29.84

+6.46

+22.61 TO+27.29

+21.86 TO+33.63

-0.22

-0.07

+0.69

+0.11

+14.70

+5.61 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET PROBE 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:14:54 Component: S/G A Page 4 of 56 ATTACHMENT #1 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW TUBE VOLTS 13 74 11.59 9.52 16.23 14 9

0.38 14 11 0.59 14 17 0.53 14 19 1.01 14 53 0.53 14 58 0.28 14 66 0.27 0.19 0.32 14 71 0.57 14 74 15.27 0.32 14 75 0.72 15 5

1.10 15 14 0.33 15 61 0.30 0.30 15 70 0.74 15 75 0.39 15 77 0.41 0.50 0.49 16 1

0.37 16 12 0.18 16 28 7.99 16 46 0.40 16 59 10.40 16 74 0.42 0.82 16 78 0.68 17 1

0.57 17 2

0.98 17 5

0.47 17 10 0.86 17 73 0.64 17 74 0.80 0.92 17 75 1.45 17 76 0.90 17 77 0.71 17 78 1.16 17 79 2.01 18 9

0.21 18 10 0.72 18 49 1.25 1.49 18 62 0.27 18 75 0.48 18 76 0.67 18 77 0.46 38.61 0.96 18 79 0.71 18 84 0.84 6.06 18 85 0.39 19 77 0.30 0.58 19 79 0.30 19 80 1.02 20 10 0.23 20 38 0.34 20 55 6.83 20 58 0.31 20 78 0.69 21 5

0.72 21 6

0.91 21 33 0.68 21 46 0.63 21 52 0.81 21 62 0.54 22 26 0.38 DEG 15 192 187 79 84 74 140 110 99 95 86 106 108 12 87 103 98 93 89 118 113 85 92 98 106 108 100 188 73 186 96 102 95 75 103 87 95 112 107 83 104 116 95 123 106 87 98 116 145 97 113 108 113 176 106 103 80 175 95 90 111 70 74 84 84 182 99 49 97 106 103 57 106 104 95 CH P

F P

P 3

P P

3 3

3 P

3 3

F F

3 P

3 3

3 3

P 3

P P

3 3

3 3

3 3

3 P

P P

P P

3 3

P 3

3 3

3 P

3 p

3 3

P 3

P 3

3 P

3 P

3 3

P 3

P P

P P

3 P

F P

P P

3 P

3 3

N IND 1 NQI 1 DNT 1 DNT 1 NQI NQI 1 NQI 1 NQI NQI NQI TWD 1 NQI NQI NQI 1 DNT 1 NQI TWD 1 NQI NQI NQI NQI NQI 1 NQI NQI 1 NQI 1 NQI NQI NQI DNT NQI DNT NQI NQI 1 NQI 1 NQI 1 NQI 1 NQI 1 NQI NQI NQI 1 NQI NQI NQI NQI NQI 1 NQI NQI 1 NQI NQI NQI 1 NQI NQI 1 NQI NQI DNT 1 NQI NQI 1 NQI DNT NQI 1 NQI NQI 1 NQI 1 NQI 1 NQI 1 NQI DNT 1 NQI 1 NQI 1 NQI 1 NQI 1 NQI NQI 1 NQI NQI NQI

%TW LOCATION 015

+0.77 015

+0.60 UTS

-0.02 015

+0.29 014

+7.09 007

+0.71 007

-0.80 003

+22.89 010

+16.97 37 014

+15.85 015

-0.11 009

+19.63 TO+28.77 009

+34.83 UTS

-0.13 010

+0.35 22 014

+32.39 009

+0.45 013

-1.33 014

+19.72 014

+1.11 009

+28.04 014

+0.95 012

+25.83 LTS

+0.60 LTS

-0.52 012

+7.39 012

+25.87 008

+28.65 LTS

+26.02 005

+35.33 011

+19.87 009

+20.43 TO+28.25 014

+0.73 UTS

-0.58 010

+0.47 008

+0.31 009

-0.77 009

+14.49 TO+25.44 009

+8.94 TO+29.78 011

-0.79 009

+15.08 TO+29.98 009

+11.61 TO+29.56 009

+15.78 TO+30.11 009

+17.41 TO+25.85 014

+0.86 013

+24.74 009

-0.80 015

+40.69 015

+40.29 015

+0.20 014

+1.04 014

+0.81 009

+12.90 TO+28.13 LTS

+14.17 014

+0.71 009

+16.55 TO+24.87 LTS

-0.02 LTE

+10.27 003

+33.24 015

+0.46 014

+1.12 014

+1.06 014

+0.70 014

+0.20 014

+0.31 001

+29.08 014

+0.42 007

+0.71 009

-0.51 010

+0.53 015

+0.75 002

+33.09 014

+0.49 014

+27.83 014

+9.83 EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 5lOUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL S5OUL 51OUL 51OUL 51OUL S5OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:14:54 Component: S/G A Page 5 of 56 ATTACHMENT #1 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW TUBE VOLTS 22 41 0.42 22 51 6.86 22 70 0.27 22 73 0.32 22 74 0.34 22 91 0.69 22 93 21.40 13.00 0.56 23 1

1.09 0.70 23 2

0.66 23 3

0.54 23 5

0.32 23 23 6.63 23 43 0.60 23 44 20.44 23 65 0.26 23 80 0.70 23 82 0.31 23 93 17.59 23 94 12.92 0.94 24 4

0.55 24 5

0.51 0.88 24 14 0.52 24 44 0.68 0.37 24 94 12.09 25 15 0.32 25 26 0.30 25 41 0.26 0.28 25 46 0.35 25 83 0.55 25 94 0.92 1.18 25 95 0.90 26 37 0.52 26 54 0.61 26 89 0.26 26 92 0.84 27 41 0.24 27 57 0.55 27 68 0.46 27 72 0.35 27 78 0.38 27 92 0.56 27 98 1.14 0.88 28 1

0.52 28 2

0.42 28 3

0.43 28 6

0.50 28 27 0.58 28 37 0.41 0.52 28 45 0.32 28 55 0.57 28 56 0.41 28 64 0.29 28 79 0.57 28 90 0.43 28 96 0.44 29 2

1.10 29 12 0.39 29 13 0.34 29 25 0.40 29 56 0.47 29 57 0.90 29 59 0.33 29 98 0.32 0.40 29 103 0.31 DEG 68 188 73 113 93 88 191 198 95 66 65 71 127 114 192 129 180 111 77 111 191 193 100 81 80 99 107 101 114 25 76 89 81 104 103 108 100 87 61 80 72 98 95 98 84 73 77 94 109 79 87 83 95 103 106 71 78 64 95 68 96 82 102 99 74 104 88 105 84 93 100 102 95 80 97 CHN 3

3 3

3 3

P 1 P 1 P 1 3

P 1 P1 P 1 3

P 1 3

P 1 3

P 1 3

P 1 P 1 P I P 1 P 1 P 1 P 1 3

P 1 P 1 P 1 3

3 3

3 3

3 P 1 P 1 P 1 3

3 P 1 P 1 3

3 P 1 P1 3

3 P1 3

P 1 P 1 P 1 P 1 P1 3

3 3

3 3

3 3

P 1 3

P1 3

3 3

P 1 P 1 P 1 P 1 P 1 3

IND NQI DNT NQI NQI NQI NQI DNT DNT NQI NQI NQI NQI NQI NQI DNT NQI DNT NQI NQI NQI DNT DNT NQI NQI NQI NQI NQI NQI NQI BLG NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI 6TW LOCATION 015

+32.53 002

+5.94 002

+17.75 001

+30.65 013

+11.81 010

+0.55 UTS

+0.02 015

+0.64 015

+15.93 UTS

+0.61 009

-0.29 010

+0.38 009

+14.39 009

-0.54 LTE

+7.28 014

+0.73 LTS

+18.13 014

+0.24 003

+30.69 009

-0.15 UTS

-0.07 UTS

+0.00 011

-0.82 009

+0.47 009

-0.31 010

+0.45 004

+10.11 014

+0.20 014

+0.73 UTS

-0.13 008

+10.76 013

+31.68 009

+18.73 007

+36.78 015

+17.57 015

+33.94 009

-0.68 009

+0.55 008

+0.51 002

+15.60 010

+16.52 009

-0.42 008

-0.58 015

+8.04 004

+16.85 014

+0.38 015

+0.40 004

+23.65 010

+10.55 011

-0.77 014

+33.31 UTS

+0.64 010

+0.51 010

+0.60 009

-0.64 LTS

-0.29 012

+31.64 TO+35.72 010

+29.38 TO+33.65 009

+21.97 006

+20.70 012

+20.57 011

+20.18 LTS

+40.70 001

+0.33 015

+22.69 010

-0.20 010

+22.12 008

+35.88 011

+3.20 014

+1.00 014

+1.00 014

+0.42 015

-0.18 015

-0.46 014

+11.64 EXT UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE EXT LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTIL 1 UTIL 2 CAL # LEG 61 OUTLET 84 OUTLET 83 OUTLET 84 OUTLET 83 OUTLET 84 OUTLET 84 OUTLET 84 OUTLET 84 OUTLET 61 OUTLET 61 OUTLET 61 OUTLET 60 OUTLET 60 OUTLET 60 OUTLET 60 OUTLET 61 OUTLET 87 OUTLET 84 OUTLET 84 OUTLET 83 OUTLET 84 OUTLET 84 OUTLET 60 OUTLET 61 OUTLET 61 OUTLET 60 OUTLET 60 OUTLET 60 OUTLET 88 OUTLET 60 OUTLET 61 OUTLET 60 OUTLET 60 OUTLET 61 OUTLET 87 OUTLET 88 OUTLET 88 OUTLET 87 OUTLET 61 OUTLET 88 OUTLET 87 OUTLET 88 OUTLET 57 OUTLET 88 OUTLET 87 OUTLET 87 OUTLET 87 OUTLET 88 OUTLET 88 OUTLET 88 OUTLET 57 OUTLET 56 OUTLET 98 OUTLET 56 OUTLET 57 OUTLET 56 OUTLET 56 OUTLET 56 OUTLET 88 OUTLET 87 OUTLET 87 OUTLET 88 OUTLET 87 OUTLET 87 OUTLET 56 OUTLET 56 OUTLET 57 OUTLET 57 OUTLET 88 OUTLET 87 OUTLET 87 OUTLET 88 OUTLET 88 OUTLET 87 OUTLET PROBE 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL S5OUL 51OUL S5OUL 51OUL 51OUL 51OUL S5OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:14:54 Component: S/G A Page 6 of 56 ATTACHMENT #1 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW TUBE VOLTS 29 104 11.96 2.45 30 1

0.93 3.18 30 7

0.45 30 19 0.26 30 32 0.26 0.21 30 50 16.13 30 76 0.28 30 80 0.79 31 1

0.47 31 2

0.54 31 7

0.36 31 8

0.56 0.34 31 48 0.84 31 56 0.72 31 57 0.45 0.18 0.29 31 59 0.29 31 61 0.41 31 71 0.32 31 73 8.13 31 74 0.61 0.39 1.01 31 105 0.33 32 1

0.56 32 3

1.33 32 14 0.57 32 19 0.37 32 57 0.29 32 69 0.30 0.33 0.22 32 88 1.87 33 1

0.40 0.66 33 2

0.25 33 3

0.61

0. 65 33 6

0.59 33 7

0.37 0.51 0.29 33 17 0.58 1.08 33 21 0.74 33 53 0.30 0.23 0.21 0.27 0.42 33 80 0.37 0.27 33 98 0.60 34 6

0.44 34 13 0.59 34 41 0.32 34 45 0.39 34 64 0.83 34 84 0.62 34 86 0.50 34 87 0.63 34 88 0.34 34 89 2.82 35 1

8.90 35 2

1.24 35 41 0.64 35 42 0.49 35 52 7.78 35 64 0.15 35 90 0.79 DEG 23 96 98 127 83 82 90 107 180 72 97 83 86 88 105 82 75 120 85 96 102 95 89 106 180 98 89 99 86 94 115 104 116 101 106 72 78 117 109 61 115 114 100 133 106 128 85 72 172 82 81 104 112 100 124 99 89 65 88 118 89 83 93 84 75 98 84 88 181 106 51 88 184 83 90 CH P

P 3

3 P

3 3

3 3

3 P

P P

P P

3 P

3 3

3 p

3 3

P 3

3 3

3 3

3 P

3 3

3 3

3 3

3 3

P 3

P P

P 3

3 3

3 3

P 3

3 3

3 3

3 3

3 3

P 3

P 3

3 P

P 3

P P

3 P

P 3

P P

N IND 1 BLG 1 NQI NQI NQI 1 NQI NQI NQI NQI DNT NQI 1 NQI 1 NQI 1 NQI 1 NQI 1 NQI NQI 1 NQI NQI NQI NQI 1 NQI NQI NQI 1 NQI DNT NQI NQI NQI NQI NQI 1 NQI NQI NQI NQI NQI NQI NQI NQI NQI 1 NQI NQI 1 NQI 1 NQI 1 NQI NQI NQI NQI DWI DNT 1 TWD NQI NQI NQI NQI NQI NQI NQI NQI NQI 1 NQI NQI 1 NQI NQI NQI 1 NQI 1 NQI NQI 1 NQI 1 DNT TWD 1 NQI 1 NQI DNT 1 NQI 1 NOI

%TW LOCATION UTS

-0.11 015

-0.79 015

+9.53 015

+1.24 014

+0.44 010

+10.30 011

+7.88 014

+18.61 001

+10.82 LTS

+12.22 014

+1.00 007

+0.41 012

+0.69 009

+0.38 010

+0.51 011

+26.48 013

-0.91 015

+39.43 011

+24.14 011

+22.00 014

-0.49 011

+7.03 011

+2.94 015

+0.42 005

+35.31 009

+24.05 008

+7.62 006

+16.66 015

+37.29 015

+18.36 010

+0.67 007

+21.72 010

+30.83 011

+14.93 TO+17.38 014

+5.85 007

+25.16 007

+31.71 LTS

+21.50 TO+29.84 015

+16.27 012

+0.67 014

+5.92 010

-0.36 010

+0.64 010

+0.54 013

+14.36 013

+7.78 013

+7.49 013

+6.46 013

+6.26 39 014

+0.94 010

+23.75 010

+8.93 010

+2.19 009

+27.19 005

+12.09 014

+26.77 014

+17.52 003

+19.04 008

+37.44 008

-0.78 006

+19.87 014

+0.43 004

+9.78 004

+14.46 003

-0.82 015

-0.04 011

+5.32 001

+0.84 015

+0.75 18 015

+35.27 015

+0.62 014

+0.35 LTS

+18.34 014

+0.09 001

+0.91 EXT UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE EXT LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTIL 1 UTIL 2 CAL #

88 88 57 57 56 56 57 57 57 87 87 57 56 56 56 56 53 88 87 87 87 87 87 87 87 88 88 88 87 53 52 52 53 87 87 87 87 96 53 53 53 52 52 53 52 52 52 52 52 53 53 53 53 53 53 95 95 95 53 52 53 53 96 96 96 95 95 96 53 53 53 52 53 95 95 LEG PROBE OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:14:54 Component: S/G A Page 7 of 56 ATTACHMENT #1 LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW 35 35 35 35 36 36 36 36 36 36 36 36 36 37 37 37 37 37 37 38 38 38 38 38 38 39 39 39 39 39 39 40 40 40 40 40 40 40 40 40 41 41 41 41 41 41 41 41 41 41 41 41 42 42 42 42 42 42 42 42 42 42 42 42 TUBE 98 100 101 108 1

4 11 22 44 96 108 111 113 4

13 22 47 51 54 3

4 66 74 99 115 35 44 57 114 115 116 2

12 39 57 59 61 76 114 115 54 55 56 57 60 63 77 87 103 112 113 116 59 60 61 62 63 64 65 66 67 68 96 116 VOLTS 0.49 0.34 0.41 0.38 20.23 0.59 2.87

9. 90 0.38 0.32 0.25
0. 64 0.47 1.01 0.75 0.96 7.44 0.83 0.54 1.04 0.23 0.58 0.42 0.29 14.10 0.83 1.09 0.28 0.32 0.37
0. 95 0.26 0.30 0.24 6.36 1.03
0. 68 1.88 1.49 0.75 0.50 0.56 0.48 0.41 9.21 7.44 6.04 0.24 0.35 0.79 6.17 6.42 6.82 6.77 6.40 6.21 7.06 0.49 0.76 0.94 0.67 10.86 7.93 7.46 6.75 8.36 9.05 10.70 7.50 7.18 7.06 6.55 0.46 8.38 0.72 DEG 82 82 98 101 187 86 45 200 113 94 84 87 88 75 132 90 193 50 112 122 85 106 110 102 180 110 102 79 82 80 109 97 98 86 184 92 115 116 116 109 109 95 89 82 182 182 172 96 74 90 174 181 180 181 172 170 177 111 74 103 108 6

180 176 176 170 172 174 172 172 180 179 81 185 136 CHN 3

3 3

3 P 1 3

6 P 1 3

3 3

P 1 P 1 3

P 1 P 1 P 1 6

3 3

P 1 3

3 3

3 P 1 P 1 3

3 P 1 P 1 3

3 3

P 1 P 1 3

4 4

4 P 1 P 1 P1 3

P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 2 1 P 1 2 1 P1 3

3 3

P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 3

2 1 3

IND %TW LOCATION NQI 013

+28.32 NQI 001

+2.89 NQI 009

+29.12 NQI 003

+35.13 DNT UTS

+0.02 NQI 015

+44.93 ADI 015

+32.27 DNT 015

+0.57 NQI 010

+5.00 NQI 013

+14.47 NQI 004

+29.85 NQI 015

+0.52 NQI 015

+0.38 NQI 010

+29.10 NQI 008

-0.80 NQI 011

-0.82 DNT UTS

-0.02 ADI 015

+26.21 TO+36.95 NQI 015

+35.25 NQI 014

+1.11 NQI 015

+0.25 TWD 18 008

+5.15 NQI 001

+27.95 NQI 015

+13.63 DNT LTS

+18.18 NQI 014

+0.75 TWD 14 014

+1.11 NQI LTS

+24.75 NQI 013

+9.74 NQI 001

-0.80 NQI 007

-0.79 NQI 015

+35.18 NQI 014

+2.43 NQI 014

+7.07 DNT LTS

-0.07 NQI 013

+0.91 NQI 012

+1.25 TWD 12 008

+26.20 TWD 16 007

+24.03 TWD 22 008

+3.07 NQI 013

-0.77 NQI 015

+0.99 NQI 004

-0.75 NQI 014

+7.70 DNT LTS

+0.00 DNT LTS

+0.00 DNT LTS

-0.02 NQI 014

+0.33 NQI 007

-0.80 NQI 012

+0.80 DNT LTS

-0.07 DNT LTS

-0.07 DNT LTS

-0.07 DNT LTS

-0.04 DNT LTS

-0.04 DNT LTS

-0.02 DNT 014

+15.68 NQI 006

+30.07 NQI 006

+25.79 NQI LTE

+21.94 NQI 009

-0.77 BLG UTS

-0.16 DNT LTS

-0.09 DNT LTS

-0.02 DNT LTS

+0.00 DNT LTS

-0.04 DNT LTS

-0.02 DNT LTS

-0.11 DNT LTS

-0.24 DNT LTS

-0.07 DNT LTS

-0.04 DNT LTS

-0.02 NQI 011

+26.22 DNT UTS

+0.00 NQI 014

+1.11 EXT UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE EXT LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTIL 1 UTIL 2 CAL 96 96 96 95 96 96 96 96 48 47 48 48 52 96 131 96 96 96 131 47 48 47 48 53 52 47 47 131 96 95 97 97 48 47 53 97 95 97 97 97 47 47 47 47 52 52 97 98 98 97 45 97 41 97 101 101 101 102 102 101 102 102 41 101 101 102 101 102 101 102 101 102 101 101 101 LEG OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET PROBE 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:14:54 Component: S/G A Page 8 of 56 Component: S/C A Page 8 of 56 ATTACHMENT #1 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW TUBE VOLTS

0. 64 42 117 21.27 30.87 6.09 43 1

0.73 43 7

0.56 43 14 10.82 43 56 6.82 43 57 13.25 43 58 9.40 43 59 9.56 43 60 6.43 43 61 9.62 43 62 9.69 43 63 11.63 43 64 14.03 43 65 14.52 7.53 43 66 11.85 0.28 43 67 10.62 43 68 8.83 43 69 11.99 43 70 7.87 43 71 8.06 43 73 0.30 43 83 0.37 43 116 1.29 43 117 11.75 0.51 44 4

0.59 44 34 0.65 44 38 0.41 44 53 6.10 44 54 6.84 44 56 12.03 44 57 13.54 44 58 13.47 44 61 8.09 44 62 11.83 44 63 11.45 44 64 10.11 44 65 14.58 44 66 0.64 10.11 44 67 8.19 44 68 10.96 44 69 10.29 44 70 7.17 44 71 11.41 44 72 10.63 44 73 10.08 44 115 0.39 44 116 0.67 45 1

0.42 45 32 0.36 45 44 0.30 0.35 0.27 45 46 6.23 45 47 6.70 45 50 0.25 45 54 7.79 45 55 7.61 45 56 8.26 45 57 12.36 45 58 13.87 45 59 0.96 16.61 45 60 9.77 45 61 7.87 45 62 11.34 45 63 11.83 45 64 0.47 0.30 DEG 53 8

183 64 123 87 112 180 185 179 179 170 175 177 177 174 175 189 174 88 173 172 174 178 169 82 86 98 8

42 92 105 105 184 172 177 184 178 177 177 176 175 177 77 185 176 175 176 165 176 171 170 99 91 77 115 88 63 111 185 175 88 174 184 175 184 175 94 184 176 178 173 176 79 95 CHN IND 6

ADI P 1 BLG P 1 DNT 6

ADI P 1 NQI P 1 NQI 3

NQI P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT 3

DNT P 1 DNT P 1 NQI P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT 3

NQI 3

NQI P 1 NQI P 1 BLG 6

ADI P 1 TWD 3

TWD 3

TWD P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT 3

NQI P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 NQI P 1 NQI 3

NQI P 1 NQI 3

TWD 3

NQI 3

TWD P 1 DNT P 1 DNT 3

NQI P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT 3

NQI P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT 3

NQI 3

NQI

%TW LOCATION 015

+35.10 TO+29.77 015

+0.90 UTS

+0.17 015

+29.63 TO+34.46 013

-0.89 008

+0.63 LTS

+22.77 TO+30.36 LTS

-0.11 LTS

-0.04 LTS

-0.04 LTS

-0.02 LTS

-0.02 LTS

-0.07 LTS

+0.02 LTS

+0.00 LTS

+0.04 LTS

+0.00 UTS

+19.57 LTS

+0.02 UTS

+5.95 LTS

-0.11 LTS

-0.04 LTS

+0.00 LTS

-0.15 LTS

+0.02 013

+15.43 011

+17.19 009

-0.55 UTS

-0.18 015

+31.95 39 010

+1.17 20 007

+3.88 22 013

+23.51 LTS

-0.07 LTS

-0.02 LTS

+0.00 LTS

-0.02 LTS

+0.00 LTS

-0.04 LTS

-0.02 LTS

-0.02 LTS

+0.02 LTS

-0.11 006

+25.86 LTS

+0.07 LTS

-0.04 LTS

-0.02 LTS

-0.15 LTS

-0.02 LTS

-0.04 LTS

+0.09 LTS

-0.02 009

+0.20 014

+0.73 015

+23.80 014

-0.13 46 010

+17.13 010

+15.41 12 010

+15.18 LTS

-0.04 LTS

+0.00 011

+18.79 LTS

+0.00 LTS

-0.02 LTS

+0.00 LTS

-0.04 LTS

+0.02 015

+1.38 LTS

-0.04 LTS

-0.02 LTS

+0.04 LTS

+0.00 LTS

+0.02 009

+26.71 007

+4.45 EXT EXT UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTIL 1 UTIL 2 CAL 101 102 102 102 40 40 41 41 40 41 41 101 102 101 102 101 102 102 101 101 102 101 102 101 102 102 102 101 102 102 41 41 40 40 39 39 40 39 101 102 101 102 101 102 102 101 102 101 102 101 102 101 101 102 36 40 40 40 40 40 39 39 39 40 39 40 39 40 40 39 101 102 101 102 102

  • LEG OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET PROBE 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 5lOUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:14:54 Component: S/G A Page 9 of 56 ATTACHMENT #1 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW TUBE VOLTS 10.39 45 65 13.61 45 66 15.85 45 67 12.92 45 68 10.61 45 69 16.58 45 70 13.12 45 72 0.51 8.01 45 73 12.51 0.56 45 74 17.31 45 75 7.56 45 76 6.61 45 112 0.47 45 113 0.77 45 117 0.60 46 3

0.40 46 7

6.59 0.67 46 39 0.30 46 47 6.86 46 54 9.63 46 55 9.11 46 56 12.99 46 57 15.26 46 58 15.38 46 59 1.10 16.34 46 60 12.22 46 61 11.89 46 62 12.38 46 63 14.01 46 65 15.17 46 66 12.39 46 67 17.11 46 68 0.31 0.30 23.51 46 69 16.12 46 70 15.49 46 71 16.94 46 72 26.91 46 73 17.12 46 74 12.64 46 75 9.39 46 77 0.46 6.26 46 78 7.17 46 92 0.30 46 94 0.22 0.21 46 105 0.43 46 116 0.32 46 119 0.96 47 1

0.31 47 7

12.41 47 51 7.06 47 52 6.89 47 53 10.00 47 54 7.79 47 55 9.07 47 56 13.62 47 57 25.43 0.49 47 58 17.46 47 59 30.33 47 60 28.93 47 61 20.44 47 62 12.50 47 63 0.90 17.45 47 64 21.17 47 65 13.26 47 66 8.43 DEG 174 175 180 177 180 177 179 76 174 179 104 178 183 178 111 117 96 103 176 113 121 182 184 181 178 180 181 110 181 181 177 174 177 175 175 180 105 77 176 181 175 179 176 180 176 182 76 182 179 81 102 69 103 90 122 95 177 184 182 184 184 180 180 182 80 180 182 181 180 178 89 181 175 178 174 CHN P 1 P 1 P 1 P 1 P 1 P 1 P1 3

P 1 P 1 P 1 P1I P 1 P 1 3

P 1 P 1 3

3 3

P1 P1 P 1 P 1 P 1 P 1 P 1 3

P 1 P 1 P 1 21I P 1 P 1 P 1 P 1 3

3 P 1 2 1 P 1 P 1 2 1 21 P 1 P 1 P 1 P 1 P1 3

3 3

P 1 3

3 3

P 1 P 1 P 1 2 1 P 1 P 1 P 1 3

2 1 2 1 2 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 IND %TW LOCATION BUT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS NQI 011 DNT LTS DNT LTS NQI 014 DNT LTS DNT LTS DNT LTS NQI 002 NQI 003 NQI 014 NQI 009 DNT LTE NQI 015 NQI 014 DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS TWD 10 015 DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS NQI 015 NQI LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS NQI 014 DNT LTS DNT LTS NQI 001 NQI 014 NQI 014 NQI 015 NQI 006 NQI 010 NQI 015 DNT LTE DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS NQI 015 DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS NQI 015 DNT LTS DNT LTS DNT LTS DNT LTS

+0.09

+0.00

+0.04

-0.02

-0.04

-0.07

+0.00

+19.06

+0.07

-0.11

+0.49

+0.02

+0.04

-0.13

+35.52

+0.69

+0.93

+38.65

+10.98

+1.25

+0.96

+0.00

-0.07

-0.02

-0.02

+0.00

+0.00

+1.78

+0.02

-0.02

+0.02

+0.00

+0.33

+0.09

-0.02

+0.02

+32.77

+39.85

+0.11

+0.07

+0.09

+0.00

+0.00

+0.02

+0. 00

-0.11

+0.36

-0.02

-0.17

+13.83

+11.17

+10.77

+36.49

-0.42

+1.35

+18.91

+10.93

-0.07

-0.04

-0.07

-0.04

+0.02

-0.02

-0.02

+31.21

+0.00

+0.09

+0.09

+0.04

+0.00

+0.82

+0.35

-0.04

+0.40

+0.07 EXT UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE EXT LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTIL 1 UTIL 2

==

CAL #

102 101 102 106 107 106 107 106 106 107 107 106 107 106 107 106 106 35 35 35 35 35 36 35 36 35 36 35 35 97 106 106 107 106 106 107 106 106 106 107 106 107 106 107 106 107 107 107 106 106 106 106 107 106 107 36 36 36 35 36 35 36 35 36 36 35 36 35 35 106 107 107 106 107 106 LEG OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET PROBE 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:14:54 Component: S/G A Page 10 of 56 ATTACHMENT #1 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW 47 47 47 47 47 47 47 47 47 47 47 47 47 47 47 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 49 49 49 49 49 49 49 49 49 49 49 49 49 TUBE 67 68 69 70 71 72 73 74 75 76 78 79 80 81 104 5

15 31 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 84 101 117 122 1

7 17 46 51 52 53 54 55 56 57 58 59 VOLTS 10.04 14.05 12.98 10.08 8.46 12.66 27.66 18.55 48.02 22.01 8.19

8. 92 9.50 7.92 0.41 0.32 0.41 0.48 0.98 8.56
9. 63 12.29 12.02 11.03 13.83 14.85 38.70 35.86 43.39 22.73 18.94
9. 90 11.48 12.87 15.90 9.52 9.27 6.54 0.18
7. 97 6.78
8. 64 14.06 0.41 22. 13 34.45 0.31 54.70 30.79 0.24 29.03 17.33 0.16 17.05 9.92 0.32 8.98 6.55 0.22 0.26 10.72 5.94 0.27 0.58 8.24 0.38 7.88 8.45
9. 02 9.37 9.28 13.51 14.58 42.22 38.20 DEG 176 175 180 175 177 176 181 172 181 176 177 180 180 183 86 99 110 105 109 181 183 179 180 181 180 178 183 178 183 179 179 179 180 174 176 174 180 177 69 168 175 183 174 104 184 176 88 181 177 90 182 178 93 178 178 89 183 175 110 110 189 19 107 88 182 110 186 182 181 179 183 181 180 180 183 CHN P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 21 3

3 3

P 1 3

P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 3

P 1 P 1 3

P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 3

P 1 P 1 P 1 P 1 3

3 3

P 1 P 1 P 1 P 1 P 1 P1 P1 P 1 P 1 IND DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT NQI NQI NQI NQI NQI DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT NQI DNT DNT DNT DNT NQI DNT DNT NQI DNT DNT NQI DNT DNT NQI DNT DNT NQI DNT DNT NQI NQI DNT NQI NQI NQI DNT NQI DNT DNT DNT DNT DNT DNT DNT DNT DNT

%TW LOCATION LTS

-0.07 LTS

+0.02 LTS

-0.07 LTS

+0.02 LTS

+0.00 LTS

+0.07 LTS

+0.13 LTS

+0.09 LTS

+0.00 LTS

+0.00 LTS

-0.11 LTS

-0.09 LTS

-0.20 LTS

-0.02 015

+13.42 014

+14.63 011

+26.18 015

+0.50 012

+17.33 LTS

-0.06 LTS

-0.04 LTS

-0.02 LTS

-0.09 LTS

+0.00 LTS

+0.00 LTS

+0.02 LTS

-0.02 LTS

+0.07 LTS

+0.00 LTS

+0.04 LTS

-0.02 LTS

+0.04 LTS

+0.07 LTS

+0.40 LTS

+0.00 LTS

+0.16 LTS

+0.02 LTS

+0.02 014

+0.34 LTS

+0.00 LTS

+0.20 LTS

+0.16 LTS

+0.00 006

+22.44 LTS

+0.11 LTS

+0.04 011

+11.99 LTS

+0.09 LTS

+0.07 014

+0.27 LTS

+0.02 LTS

-0.07 014

+0.16 LTS

-0.02 LTS

+0.00 015

+0.42 LTS

-0.04 LTS

-0.09 015

+32.94 015

-0.13 UTS

-0.04 UTS

-0.22 015

-0.09 009

+24.76 UTS

+11.81 009

+22.11 LTS

-0.07 LTS

-0.02 LTS

-0.07 LTS

+0.02 LTS

+0.04 LTS

+0.00 LTS

-0.02 LTS

+0.07 LTS

+0.00 EXT UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE EXT LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTIL 1 UTIL 2 CAL #

107 106 107 106 107 106 107 106 107 106 106 107 106 107 106 35 35 35 35 35 36 35 36 35 36 35 44 41 44 41 41 125 126 125 126 125 126 106 106 107 106 107 106 107 107 106 107 107 106 106 107 106 107 107 106 106 107 107 106 106 107 31 31 31 31 35 36 35 36 35 36 35 36 35 44 LEG PROBE OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET SlOUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:14:54 Component: S/G A Page 11 of 56 ATTACHMENT #1 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW 4=9 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 so TUBE 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 83 84 106 118 119 123 23 47 50 51 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 95 106 VOLTS 45.93

29. 64 25.85 12.20 19.06 11.28 17.30 9.58 13.19 13.19 10.62 0.33 6.53 7.56 7.11 6.85 16.05 28.21 43.03 1.26 41.29 34.19 24.69 34.53 15.08 13.26 10.16 0.33 0.54 0.27 0.34 0.58 1.15 11.36 0.42 6.60 8.57 9.52
10. 68 10.39 12.35 12.10 34.79 40.04 54.87 31.25 39.40 32.44 21.69 14.83 20.74 18.76 18.93 15.24 12.76 13.41 13.46 8.24 10.30 16.20
53. 60 40.30 50.04 24.33 28.39 30.51 27.94 0.27 26.54 14.19 12.14 7. 68
0. 64 3.20 0.42 DEG 177 183 178 177 180 176 178 173 179 180 175 90 166 175 180 163 174 179 175 131 183 178 183 178 177 178 178 83 107 76 95 98 40 191 73 179 178 182 178 180 181 175 180 179 183 179 182 180 177 175 178 173 180 174 181 175 175 172 180 177 181 176 180 177 181 177 181 74 177 181 177 179 99 120 97 CHN P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 3

P 1 P 1 P 1 P 1 P 1 P 1 P 1 3

P 1 P 1 P 1 P 1 P 1 P 1 P 1 3

3 P 1 P 1 P 1 6

P 1 3

P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P I P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 3

3 IND DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT NQI DNT DNT DNT DNT DNT DNT DNT NQI DNT DNT DNT DNT DNT DNT DNT NQI NQI NQI NQI NQI ADI DNT NQI DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT NQI DNT DNT DNT DNT NQI NQI NQI 6TW LOCATION LTS LTS H

LTS H

LTS H

LTS LTS H

LTS H

LTS A

LTS A

LTS A

LTS A

015 H

LTS LTS H

LTS H

LTS LTS LTS H

LTS H

011 H

LTS H

LTS H

LTS H

LTS H

LTS H

LTS H

LTS H

009 H

006 H

015 H

010 H

011 H

015 H

UTS 015 H

LTS H

LTS H

LTS H

LTS H

LTS H

LTS H

LTS H

LTS H

LTS H

LTS LTS LTS LTS LTS 2

LTS 2

LTS 2

LTS 2

LTS 2

LTS LTS 2

LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS 014 LTS LTS LTS LTS 014 LTS 011

-0.07

-0.04

-0.00

-0.16

-0.02

-0.22

-0.00

-0.36

-0.11

-0.00

-0.00

-44. 78

-0.04

-0.27

-0.35

-0.02

-0.11

-0.11

-0. 11

-28.09

-0. 11

-0.04

-0.04

-0.00

-0.00 0.00

-0.00

+22.38

+32.44

+0.20 20.38 0.71

+31.81

-0.04

+4. 8 4 0.00

+0.00

+0. 00 0.00

+0. 00 0.00

+0.00

+0. 00

+0.04

+0.00

+0.11

+0.00

+0.04

+0.00

+0.00

+0.04

+0.00

+0.00

+0.27

-0.00

+0.00

-0.18

+0.00

+0.18

-0.00

+0.09

+0.04

+0.09

+0.07

+0.09

-0.17

+0.02

'-0.38

+-0.00

+-0.07

+-0.00

+-0.00

+0.53

+21.14 TO+30.16

+-14.56 EXT EXT UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTIL 1 UTIL 2

==

CAL #

41 44 41 125 126 125 126 125 126 126 106 107 107 106 107 107 106 107 106 106 107 106 107 106 107 106 107 107 107 107 106 107 107 107 30 30 31 30 30 31 30 41 44 41 44 41 44 41 125 125 126 125 126 125 126 106 107 106 107 106 107 106 107 106 107 106 107 107 106 107 106 107 107 107 106 LEG OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET PROBE 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 510UL 51OUL 51OUL 51OUL 51OUL 51OUL S5OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 510UL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:14:55 Component: S/G A Page 12 of 56 ATTACHMENT #1 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW TUBE VOLTS 0.30 0.29 50 123 0.63 51 1

1.05 51 5

0.36 0.45 0.63 51 12 0.34 51 29 0.38 51 48 6.81 51 49 6.96 51 50 9.06 51 51 6.87 51 52 9.95 51 53 14.56 51 54 16.89 51 55 13.57 51 56 0.49 15.18 51 57 26.16 51 58 33.29 51 59 35.22 51 60 36.90 51 61 32.33 51 62 0.35 27.25 51 63 15.68 51 64 15.52 51 65 0.42 20.01 51 66 12.71 51 67 16.29 51 68 20.82 51 69 20.49 51 70 20.01 51 71 17.92 51 72 0.32 18.13 51 73 13.02 51 74 21.00 51 75 0.30 10.44 51 76 56.34 51 77 68.26 51 78 46.28 51 79 24.07 51 80 40.15 51 81 31.05 51 82 26.19 51 83 23.90 51 84 19.07 51 95 0.22 51 98 0.31 51 110 0.39 51 121 0.93 0.45 51 123 0.57 0.51 52 2

0.61 52 16 0.30 52 43 0.21 52 46 6.33 52 48 8.92 52 49 7.68 52 50 11.04 52 51 8.65 52 52 8.12 0.40 52 53 11.04 52 54 23.04 52 55 20.33 52 56 19.85 52 57 14.76 52 58 27.61 52 59 36.11 DEG 106 87 86 64 98 87 110 74 104 180 180 176 177 180 179 179 182 53 177 182 179 183 177 182 85 179 177 181 88 176 179 176 180 176 181 175 77 179 174 180 80 176 182 177 180 177 181 177 181 177 181 62 89 111 117 90 104 72 104 64 61 179 180 179 181 180 178 58 179 178 179 179 177 176 179 CHN 3

3 6

6 3

3 3

3 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 3

P 1 P 1 P 1 P 1 P 1 P 1 3

P 1 P 1 P 1 3

P 1 P 1 P 1 P 1 P1 P1 P 1 3

P 1 P 1 P 1 3

P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P1 P 1 P 1 P1 3

P 1 P 1 P 1 P 1 P 1 P 1 3

P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1

'P 1 iP 1 P 1 IND NQI NQI ADI ADI NQI NQI NQI NQI NQI DNT DNT DNT DNT DNT DNT DNT DNT NQI DNT DNT DNT DNT DNT DNT NQI DNT DNT DNT NQI DNT DNT DNT DNT DNT DNT DNT NQI DNT DNT DNT NQI DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI DNT DNT DNT DNT DNT DNT NQI DNT DNT DNT DNT DNT DNT DNT

%TW LOCATION 011

+12.54 011

+3.62 015

+31.69 014

+32.34 014

+1.72 009

+12.09 009

+16.63 012

+8.24 014

+0.76 LTS

+0.00 LTS

+0.00 LTS

+0.00 LTS

+0.00 LTS

+0.00 LTS

+0.00 LTS

+0.00 LTS

+0.00 001

+22.97 LTS

+0.00 LTS

+0.00 LTS

+0.04 LTS

+0.00 LTS

+0.07 LTS

+0.00 012

+32.17 LTS

+0.04 LTS

+0.02 LTS

+0.07 007

+20.37 LTS

+0.00 LTS

+0.07 LTS

+0.04 LTS

+0.11 LTS

+0.04 LTS

+0.00 LTS

+0.00 013

+24.67 LTS

+0.04 LTS

-0.04 LTS

+0.00 015

+19.79 LTS

+0.07 LTS

+0.00 LTS

+0.04 LTS

+0.02 LTS

+0.07 LTS

+0.09 LTS

+0.00 LTS

+0.07 LTS

+0.00 LTS

+0.00 014

+0.22 001

+0.80 014

+3.85 008

-0.69 010

+0.31 009

-0.73 010

+0.29 011

+0.61 013

+17.04 006

+11.36 LTS

+0.00 LTS

+0.00 LTS

+0.00 LTS

+0.00 LTS

+0.00 LTS

+0.00 015

+13.99 LTS

+0.00 LTS

+0.00 LTS

+0.00 LTS

+0.00 LTS

+0.02 LTS

+0.09 LTS

+0.00 EXT UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE EXT LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTIL 1 UTIL IV 2 CAL #

106 106 107 31 31 31 31 30 31 30 31 30 31 30 31 30 31 30 30 44 41 44 41 44 41 41 125 126 125 125 126 125 126 125 126 106 107 107 106 107 106 106 107 106 107 106 107 106 107 106 107 107 106 106 107 107 107 107 30 30 31 30 30 31 30 31 30 30 31 30 31 30 41 41 41 LEG OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET PROBE 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 510UL 51OUL 5lOUL 51OUL 51OUL 51OUL 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:14:55 Component: S/G A Page 13 of 56 ATTACHMENT #1 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW 52 52 52 52 52 52 52 52 52 52 52 52 52 52 52 52 52 52 52 52 52 52 52 52 52 52 52 52 52 52 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 TUBE 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 77 78 79 80 81 82 83 84 85 86 87 100 119 123 1

2 3

35 46 48 49 50 51 52 54 55 56 57 58 59 60 61 62 63 64 65 66 67 69 71 72 73 74 75 76 77 78 79 80 81 VOLTS 31.91 22.53 19.73 30.85 19.73 21.23 28.87 32.50 25.99 20.41 19.54 0.48 26.76 0.35 14.66 20.76 22.14 20.13

39. 63 0.30
38. 65 40.77 35.88 27.15 39.47 0.34 31.03 17.28 0.56 18.91 15.11 9.82 7.66 0.34 1.01 0.64
0. 91
0. 68 0.53 0.35 6.00 6.47 6.64 0.31 10.69 9.23 10.87 26.36 26.40 0.47 28.53 14.50 15.67 29.15 19.51 22.96 50.13 26.98
34. 65 25.09 30.11 31.09 19.80 19.20 21.05 22.30 18.90 33.51 0.26 27.61 23.59 25.06 38.33
30. 35 29.21 DEG 179 179 179 179 177 181 177 180 177 180 175 94 182 89 175 179 174 176 177 85 180 178 181 177 180 101 177 181 79 177 183 176 178 94 137 78 116 97 95 83 180 181 178 77 180 178 177 179 178 89 179 179 178 179 178 179 180 179 179 182 178 180 180 177 180 174 178 176 87 178 175 178 177 181 177 CHN P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 3

P 1 3

P 1 P 1 P 1 P 1 P 1 P 1 P 1 P1 P 1 P1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 3

P 1 P 1 3

P 1 P 1 P 1 3

P 1 P 1 P 1 3

P1 P1 P 1 P 1 P 1 3

P 1 P 1 P 1 P1 P 1 P 1 P 1 P 1 P 1 P1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P21 P 1 P 1 IND DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT NQI DNT NQI DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT NQI DNT DNT NQI DNT DNT DNT DNT NQI NQI NQI NQI NQI NQI NQI DNT DNT DNT NQI DNT DNT DNT DNT DNT NQI DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT NQI DNT DNT DNT DNT DNT DNT

%TW LOCATION LTS

+0.04 LTS

+0.07 LTS

+0.07 LTS

+0.04 LTS

+0.00 LTS

+0.07 LTS

+0.07 LTS

+0.09 LTS

+0.02 LTS

+0.04 LTS

+0.00 003

+28.26 LTS

+0.00 002

+29.12 LTS

+0.04 LTS

+0.00 LTS

+0.00 LTS

+0.00 LTS

+0.00 005

-0.64 LTS

+0.00 LTS

+0.38 LTS

+0.00 LTS

+0.16 LTS

+0.00 014

+0.02 LTS

+0.00 LTS

+0.00 014

+0.24 LTS

+0.02 LTS

+0.02 LTS

+0.00 002

+35.29 015

+0.22 009

-0.77 014

+5.35 013

-0.65 011

+0.53 011

+0.63 007

+7.13 LTS

-0.06 LTS

-0.15 LTS

-0.02 LTS

+9.55 LTS

+0.00 LTS

+0.00 LTS

+0.00 LTS

-0.02 LTS

+0.00 005

+7.16 LTS

+0.00 LTS

+0.00 LTS

+0.09 LTS

+0.04 LTS

+0.00 LTS

+0.02 LTS

+0.04 LTS

+0.02 LTS

+0.02 LTS

+0.09 LTS

+0.11 LTS

+0.07 LTS

+0.09 LTS

+0.00 LTS

+0.00 LTS

+0.00 LTS

+0.00 LTS

+0.07 003

+0.27 LTS

+0.00 LTS

+0.11 LTS

+0.00 LTS

+0.00 LTS

+0.00 LTS

+0.09 EXT UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE EXT LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTIL 1 UTIL 2 CAL #

41 41 41 41 125 126 125 126 125 126 125 126 126 112 112 113 112 113 112 112 113 112 113 112 113 112 112 113 113 112 113 112 107 106 107 31 31 30 31 30 30 30 31 30 30 30 30 31 30 31 31 30 41 41 41 41 41 41 125 126 125 126 126 125 126 112 113 112 112 113 112 113 112 113 112 LEG OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET PROBE 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:14:55 Component: S/G A Page 14 of 56 ATTACHMENT #1 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW 53 53 53 53 53 53 53 53 53 53 53 53 53 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 55 TUBE 82 83 84 85 86 87 88 105 113 121 122 124 125 1

2 3

4 5

45 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 83 84 85 86 87 88 89 90 91 106 109 121 124 126 1

VOLTS 31.15 42.87 44.80 28.78 24.28 14.30 10.78 0.53 0.38 1.03 0.68 0.59 0.45 0.73

2. 92
1. 19 0.58 0.38 0.60 0.42 6.33 6.26 11.89 10.05 10.85 21.49 21.14 18.81 18.07 17.81 20.71 9.20 19.40 33.45 33.95 46.01 39.57 42.09 38.20 0.31 30.48 28.86 19.21
18. 62 22.25 20.86 0.37 19.34 25.86 19.98
32. 10 44. 34 40.07 47.30 0.61 20.79
18. 68 25.01 20.50 27.81 29.65 29.79 17.79 15.75 7.17 7.29 0.30 0.20
0. 37 0.24 0.75 1.29 0.49 0.57 0.52 DEG 181 177 181 177 180 175 181 89 72 136 73 110 103 77 96 112 74 102 109 92 178 177 177 177 178 180 179 179 179 180 170 174 179 173 182 175 175 178 182 98 177 181 176 181 179 182 63 177 181 175 176 177 176 178 119 177 176 176 176 176 176 177 174 175 170 174 78 78 108 67 102 135 103 122 113 CHN IND P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT 3

NQI 3

NQI P 1 NQI P 1 NQI 3

NQI 3

NQI 3

NQI P 1 NQI P 1 NQI P 1 NQI 3

NQI 3

NQI P 1 NQI P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT 3

DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT 3

NQI P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT 3

NQI P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT 3

NQI P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT 3

NQI 3

NQI 3

NQI 3

NQI P 1 NQI P 1 NQI 3

NQI P 1 NQI P 1 NQI

%TW LOCATION LTS

+0.02 LTS

+0.09 LTS

+0.00 LTS

+0.00 LTS

+0.00 LTS

+0.09 LTS

+0.00 007

+22.26 013

+17.38 008

-0.71 015

+0.29 002

+34.34 010

+14.74 TO+26.11 014

+2.59 TO+8.66 013

-0.81 011

+0.66 LTE

+6.13 015

+35.03 015

+24.11 015

+0.75 LTS

+0.00 LTS

+0.00 LTS

+0.00 LTS

+0.02 LTS

+0.00 LTS

-0.02 LTS

+0.00 LTS

+0.09 LTS

+0.00 LTS

+0.00 LTS

+0.11 LTS

+0.29 LTS

+0.02 LTS

+0.04 LTS

+0.13 LTS

+0.11 LTS

+0.07 LTS

+0.09 LTS

+0.13 013

+11.52 LTS

+0.02 LTS

+0.00 LTS

+0.27 LTS

+0.13 LTS

+0.11 LTS

+0.00 013

+25.83 LTS

+0.09 LTS

+0.00 LTS

+0.00 LTS

+0.09 LTS

+0.13 LTS

+0.16 LTS

+0.13 003

+8.05 LTS

+0.16 LTS

+0.11 LTS

+0.13 LTS

+0.13 LTS

+0.00 LTS

+0.11 LTS

+0.11 LTS

+0.09 LTS

+0.02 LTS

-0.24 LTS

-0.13 012

+25.46 010

+19.49 011

+3.46 LTS

+30.48 009

-0.57 009

-0.73 010

+18.83 013

-0.72 012

-1.00 EXT EXT UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTIL 1 UTIL 2 CAL #

113 112 113 112 113 112 113 112 112 112 113 113 112 31 31 30 31 30 30 30 30 31 30 31 30 31 30 31 30 46 45 46 46 45 46 45 45 125 126 125 125 126 125 126 125 126 125 125 126 112 112 112 112 112 112 112 112 112 112 112 112 112 112 112 112 112 112 112 112 112 113 112 112 31 31 LEG OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET PROBE 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL SlOUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:14:55 Component: S/G A Page 15 of 56 ATTACHMENT #1 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 56 56 56 56 56 56 56 56 56 56 56 TUBE 11 29 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 102 115 121 123 124 125 126 4

6 11 15 18 28 36 48 49 51 52 VOLTS 0.76 0.33 0.43 0.42 6.28 7.36 8.29 11.10 10.66 8.44 16.96 14.86 14.66 21.62 10.25 29.91 22.47 44.93 41.02 37.49 32.32 33.57 33.28 24.43 37.34 22.68 20.06 13.72 26.06 22.57 0.50 0.33 25.61 23.41 21.40 0.35 39.65

33. 63 36.12 43.00 19.35 18.46 26.25 27.10 19.88 37.40 38.64 19.62 19.07 9.41 8.02 0.34 0.55 1.31
1. 01 1.49 0.56 1.00 0.79 0.52 0.54 6.09
0. 90 0.38 0.40 0.64 18.25 0.41 8.21 7.68 1.76 6.46 7.77 12.01 7.26 DEG 99 59 70 60 180 181 178 178 177 178 179 179 179 178 172 180 171 180 174 182 175 178 182 179 181 179 181 179 178 182 87 84 177 175 174 94 177 176 177 178 178 176 175 176 175 178 176 176 171 176 176 112 73 119 121 127 77 133 141 110 110 171 100 102 66 74 89 86 105 87 87 181 181 180 182 CHN 3

3 3

P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P1 P1 P 1 P 1 P 1 P 1 P 1 3

3 P 1 P 1 P 1 3

P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 3

3 P 1 3

P 1 3

P 1 P 1 P 1 P 1 P 1 P 1 3

P 1 3

6 3

6 6

6 P 1 P 1 P 1 P 1 IND %TW LOCATION NQI 011 NQI 008 NQI 007 NQI 013 DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS NQI 010 NQI 011 DNT LTS DNT LTS DNT LTS NQI 006 DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS NQI 012 NQI 009 NQI 008 NQI 009 NQI 009 NQI 009 NQI 009 NQI 009 NQI 010 NQI 011 DNT UTS NQI 011 NQI 014 NQI UTS NQI 005 ADI LTS NQI 001 ADI 002 ADI LTS ADI 001 DNT LTS DNT LTS DNT LTS DNT LTS

  • 32.02
  • 22.80

+34.90

-0.46

-0.20

+0.00

-0.04

+0.00

-0.07

+0. 00

-0.02

+0.00

+0.00

+0.00

+0.00

+0.00

-0.02

+0.00

+0.07

+0.11

+0.13

+0.04

+0.13

+0.07

+0.11

+0.00

+0.09

+0.16

+0.09

+0.00

+10.29

+23.88

+0.11

+0.09

+0.09

+32.16

+0.11

+0.18

+0.18

+0.13

+0.13

+0.07

+0. 11

+0.09

+0.09

+0.09

+0.09

+0.09

+0.04

-0.17

-0.17

+14.81

+24.34

-0.73

+13.88 TO+29.91

-0.73

+29.90

-0.75

-0.58

+0.51

-0.53

-0.04

-0.79

+33.59

+11.04

+12.85

+22.09 TO+30.58

+21.11

+0.63 TO+6.81

+22.43 TO+31.00

+36.74

+0.00

+0.00

+0.00

-0.04 EXT UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE EXT LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTIL 1 UTIL IV CAL # LEG PROBE 30 OUTLET 51OUL 31 OUTLET 51OUL 31 OUTLET 51OUL 30 OUTLET 51OUL 31 OUTLET 51OUL 30 OUTLET 51OUL 31 OUTLET 51OUL 30 OUTLET 51OUL 31 OUTLET 51OUL 30 OUTLET 51OUL 31 OUTLET 51OUL 30 OUTLET 51OUL 31 OUTLET 51OUL 30 OUTLET 51OUL 45 OUTLET 51OUL 46 OUTLET 51OUL 45 OUTLET SlOUL 46 OUTLET 51OUL 45 OUTLET 51OUL 46 OUTLET 51OUL 45 OUTLET 51OUL 125 OUTLET 51OUL 126 OUTLET 51OUL 125 OUTLET 51OUL 126 OUTLET 51OUL 125 OUTLET 51OUL 126 OUTLET 51OUL 125 OUTLET 51OUL 126 OUTLET 51OUL 126 OUTLET 51OUL 126 OUTLET 51OUL 126 OUTLET 51OUL 112 OUTLET 51OUL 112 OUTLET 51OUL 112 OUTLET 51OUL 112 OUTLET 51OUL 112 OUTLET 51OUL 112 OUTLET 51OUL 112 OUTLET 51OUL 112 OUTLET 51OUL 112 OUTLET 51OUL 112 OUTLET 51OUL 112 OUTLET 51OUL 112 OUTLET 51OUL 112 OUTLET 51OUL 112 OUTLET 51OUL 112 OUTLET 51OUL 112 OUTLET 51OUL 112 OUTLET 51OUL 112 OUTLET 51OUL 112 OUTLET 51OUL 112 OUTLET 51OUL 112 OUTLET 51OUL 112 OUTLET 51OUL 112 OUTLET 51OUL 112 OUTLET 51OUL 112 OUTLET 51OUL 112 OUTLET 51OUL 112 OUTLET 51OUL 112 OUTLET 51OUL 112 OUTLET 51OUL 112 OUTLET 51OUL 31 OUTLET 51OUL 31 OUTLET 51OUL 30 OUTLET 51OUL 30 OUTLET 51OUL 31 OUTLET 51OUL 31 OUTLET 51OUL 31 OUTLET 51OUL 31 OUTLET 51OUL 31 OUTLET 51OUL 31 OUTLET 51OUL 30 OUTLET 51OUL 30 OUTLET 51OUL 31 OUTLET 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:14:55 Component: S/G A Page 16 of 56 ATTACHMENT #1 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 57 57 57 57 57 57 57 57 57 57 57 57 57 TUBE 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 121 122 124 126 127 1

2 3

4 7

12 25 32 34 45 50 51 52 VOLTS 11.01 13.50 11.20 25.40 21.24 10.99 0.29 10.32 33.18 37.87 10.89 39.23

9. 32 53.26 7.62 7.37 50.17 25.01 31.08 37.24 38.06 12.15 6.66 24.96 8.74
15. 60 12.74 19.52
20. 02 26.61 0.42 0.32 44.38 35.83 39.02 27.48 27.16 35.87 16.51 7.50 14.93 20.60 18.79 27.82 27.04 22.38 14.02 8.70 7.73 7.07 0.70
0. 61 0.78 1.33 0.63 0.39 0.92 11.84 0.43 0.42 0.32 0.76
1. 63 2.56 0.82 0.39 1.12 0.41 0.20 0.55
0. 62 0.58 7.91 8.12 9.77 DEG 178 180 180 179 179 180 87 173 179 172 176 181 175 174 182 182 174 179 182 178 180 179 181 179 179 182 179 182 176 175 109 100 178 177 177 178 178 177 174 112 176 177 176 176 176 177 177 177 176 175 108 121 105 134 148 98 60 4

82 113 94 106 107 121 102 103 87 79 93 100 92 57 180 181 179 CHN IND P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT 3

NQI P 1 DNT P 1 DNT P 1 DNT 3

DNT P 1 DNT 3

DNT P 1 DNT 3

DNT 3

DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT 3

DNT 3

DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT 3

NQI 3

NQI P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT 3

NQI P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 NQI P 1 NQI P 1 NQI P 1 NQI P 1 NQI 3

NQI 6

ADI P 1 BLG 3

NQI 3

NQI P 1 NQI P 1 NQI P 1 NQI 3

NQI P 1 NQI P 1 NQI 3

NQI 3

NQI P 1 NQI 3

NQI 3

NQI P 1 NQI P 1 DNT P 1 DNT P 1 DNT

%TW LOCATION LTS

+0.00 LTS

+0.00 LTS

+0.00 LTS

+0.20 LTS

+0.00 LTS

+0.04 011

+34.43 LTS

+0.02 LTS

+0.00 LTS

+0.04 LTS

+0.51 LTS

+0.07 LTS

+0.56 LTS

+0.07 LTS

+0.62 LTS

+0.64 LTS

+0.13 LTS

+0.07 LTS

+0.07 LTS

+0.04 LTS

+0.09 LTS

+0.80 LTS

+0.87 LTS

+0.09 LTS

+0.15 LTS

+0.18 LTS

+0.18 LTS

+0.00 LTS

+0.13 LTS

+0.18 006

+28.96 006

+26.85 LTS

+0.20 LTS

+0.18 LTS

+0.00 LTS

+0.18 LTS

+0.13 LTS

+0.04 LTS

+0.04 LTS

+21.51 TO+29.82 LTS

+0.00 LTS

+0.20 LTS

+0.11 LTS

+0.11 LTS

+0.11 LTS

+0.02 LTS

+0.07 LTS

-0.13 LTS

-0.13 LTS

-0.30 009

-0.67 011

-0.80 010

+0.49 009

-0.73 009

-0.69 010

+21.40 015

+32.66 UTS

-0.18 013

+3.01 011

+7.62 015

-0.33 011

-0.75 013

-0.75 014

+1.10 012

+0.68 006

-0.81 004

+26.46 007

+4.07 015

+0.35 004

+23.45 006

+32.72 003

-0.87 LTS

+0.00 LTS

+0.00 LTS

+0.00 EXT UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 014 014 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE EXT LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTIL 1 UTIL 2 CAL 4 30 31 30 31 30 46 45 45 46 45 45 46 46 45 45 45 45 125 126 125 126 126 125 125 126 126 125 126 112 112 112 112 112 112 112 112 112 112 112 112 112 112 112 112 112 112 112 112 112 112 112 112 112 112 112 112 112 112 112 112 112 150 132 27 26 27 26 31 30 30 30 31 30 31 30 LEG OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET PROBE 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 5lOUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 5lOUL 51OUL 5lOUL 5lOUL 51OUL 51OUL SOUL 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:14:55 Component: S/G A Page 17 of 56 ATTACHMENT #1 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW TUBE VOLTS 57 53 10.01 57 54 13.26 57 55 11.67 57 56 19.30 57 57 12.98 57 58 19.17 57 59 22.35 57 60 17.86 57 61 27.88 8.74 57 62 7.64 37.99 57 63 7.82 33.47 57 64 0.25 9.11 34.18 57 65 21.32 57 66 21.22 57 67 21.28 57 68 25.80 57 69 25.68 57 70 19.01 8.02 57 71 11.39 57 72 7.76 57 73 12.84 57 74 9.85 57 75 15.19 57 76 15.21 57 77 22.39 57 78 34.03 57 79 0.40 50.60 57 80 33.44 57 81 23.16 57 82 0.33 26.17 57 83 36.76 57 84 12.50 57 85 0.34 20.07 57 86 15.36 57 87 21.67 57 88 29.06 57 89 21.61 57 90 22.01 57 91 10.92 57 92 11.10 57 93 7.44 57 94 7.52 57 100 0.32 57 103 0.63 57 104 0.33 57 112 0.34 57 124 0.32 1.56 0.62 57 125 0.42 57 128 0.58 58 1

0.81 0.42 0.50 58 2

0.61 1.46 0.78 0.40 58 3

1.22 0.44 58 4

0.45 58 12 0.82 58 20 0.31 58 53 9.68 58 54 8.33 58 55 7.01 DEG CHN IND %TW LOCATION 181 P 1 DNT LTS

-0.09 179 P 1 DNT LTS

+0.00 179 P 1 DNT LTS

+0.00 178 P 1 DNT LTS

+0.00 179 P 1 DNT LTS

+0.00 178 P 1 DNT LTS

+0.02 179 P 1 DNT LTS

-0.02 178 P 1 DNT LTS

+0.02 181 P 1 DNT LTS

+0.27 358 3 DNT LTS

+0.69 180 3 DNT LTS

+0.55 178 P 1 DNT LTS

+0.02 181 3 DNT LTS

+0.67 182 P 1 DNT LTS

+0.09 99 3

NQI 008

+25.41 181 3 DNT LTS

+0.73 174 P 1 DNT LTS

+0.13 179 P 1 DNT LTS

+0.09 181 P 1 DNT LTS

+0.07 177 P 1 DNT LTS

+0.13 182 P 1 DNT LTS

+0.00 177 P 1 DNT LTS

+0.13 181 P 1 DNT LTS

+0.11 181 3 DNT LTS

+0.82 176 P 1 DNT LTS

+0.09 180 P 1 DNT LTS

+0.13 176 P 1 DNT LTS

+0.02 179 P 1 DNT LTS

+0.18 181 P 1 DNT LTS

+0.00 176 P 1 DNT LTS

+0.16 175 P 1 DNT LTS

+0.16 176 P 1 DNT LTS

+0.16 76 3

NQI 008

+2.85 177 P 1 DNT LTS

+0.13 177 P 1 DNT LTS

+0.00 178 P 1 DNT LTS

+0.13 118 3 NQI 006

+21.58 178 P 1 DNT LTS

+0.11 177 P 1 DNT LTS

+0.13 175 P 1 DNT LTS

+0.11 125 3 NQI 014

+32.61 177 P 1 DNT LTS

+0.00 174 P 1 DNT LTS

+0.09 177 P 1 DNT LTS

+0.24 176 P 1 DNT LTS

+0.04 176 P 1 DNT LTS

+0.09 175 P 1 DNT LTS

+0.09 175 P 1 DNT LTS

+0.04 176 P 1 DNT LTS

-0.06 179 P 1 DNT LTS

-0.17 177 P 1 DNT LTS

-0.13 89 P 1 NQI 006

-0.82 62 3

NQI 004

+16.43 82 3

NQI 001

+13.60 76 3

NQI 003

+2.66 107 P 1 NQI 015

+0.20 127 P 1 NQI 009

-0.73 98 3

NQI 009

+16.92 TO+29.49 103 3 NQI 011

+35.27 89 3

NQI 011

+5.80 TO+11.60 118 3 NQI 014

+7.31 108 3 NQI 014

+6.62 113 3 TWD 6 012

+7.31 95 P 1 NQI 010

+0.51 107 P 1 NQI 013

-0.81 115 P 1 NQI 014

-0.83 124 P 1 NQI 012

-0.64 104 P 1 NQI 011

-0.53 94 P 1 NQI 012

+1.06 94 P 1 NQI 011

-0.75 109 3 NQI 015

+2.24 107 3 NQI 010

+28.80 179 P 1 DNT LTS

-0.04 176 P 1 DNT LTS

-0.09 179 P 1 DNT LTS

-0.02 EXT UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE 014 014 014 014 014 014 014 014 014 UTE UTE UTE UTE UTE UTE EXT UTIL LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE IV LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 1 UTIL 2 CAL #

31 30 31 30 30 45 46 45 46 46 45 45 46 46 45 45 45 125 126 125 126 125 126 126 125 126 125 126 126 112 112 112 112 112 112 112 112 112 112 112 112 112 112 112 112 112 112 112 112 112 112 112 112 115 115 115 115 115 115 114 132 132 132 132 132 132 132 132 132 26 26 26 27 26 27 LEG OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET PROBE 51OUL 51OUL SIOUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:14:55 Component: S/G A Page 18 of 56 ATTACHMENT #1 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 59 59 59 59 59 59 59 59 59 59 59 59 59 59 59 TUBE 56 57 58 59 60 61 62 63 64 65 66 68 69 70 71 76 77 78 79 80 81 82 83 84 85 86 87 88 89 91 92 93 94 95 103 109 114 122 125 126 129 9

29 31 51 52 53 54 55 56 57 59 60 61 62 63 VOLTS 8.73 15.48 20.06 14.76 18.53 24.89 8.37 26.78 36.11 16.83 7.60 28.34 10.11 20.29 12.42 8.19 12.10 13.37 12.37 9.09 7.13

7. 68 13.27 22.20 26.78 25.13 21.21 23.09 28.08 26.53 37.45 17.75 17.46 17.26 0.74 25.22 25.26 15.49 13.32 7.27 6.66 0.37 0.20 0.32 0.30 0.39 0.41 0.29
0. 68 0.26 0.77 1.16
1. 0 9 0.81 0.72 0.45 0.44 0.40 7.39 7.31 7.97 11.26 16.05 22.39 22.83 15.30 24.43 10.26 51.38 9.89 27.64 15.17 21.05 13.97 16.35 DEG 175 179 176 179 170 182 183 179 182 179 178 181 181 179 179 184 178 181 176 179 180 171 187 175 189 176 184 177 190 177 183 175 182 175 104 183 173 179 175 181 175 96 58 96 105 85 102 110 135 107 108 109 119 123 106 107 68 77 88 179 181 178 179 174 180 172 172 175 175 177 177 177 178 181 178 CHN P=1 P 1 P 1 P 1 P 1 P 1 3

P 1 P 1 3

3 P 1 3

P 1 P 1 3

P 1 P 1 P 1 P 1 3

P 1 P 1 P 1 P 1 P1 P 1 P 1 P 1 P 1 P 1 P 1 P1 P 1 3

P 1 P1 P1 P 1 P 1 3

3 3

3 3

3 3

3 3

P 1 P 1 P 1 P 1 3

3 3

P 1 6

P 1 P I P 1 P 1 P 1 P 1 P1 P 1 3

P 1 3

P 1 3

P 1 3

P 1 IND DMT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT MQI DNT NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI ADI DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT

%TW LOCATION LTS

+0.04 LTS

+0.00 LTS

+0.15 LTS

+0.04 LTS

+0.09 LTS

+0.20 LTS

+0.49 LTS

+0.02 LTS

+0.27 LTS

+1.11 LTS

+0.69 LTS

+0.07 LTS

+0.69 LTS

+0.13 LTS

+0.20 LTS

+0.73 LTS

+0.13 LTS

+0.09 LTS

+0.07 LTS

+0.09 LTS

+0.89 LTS

+0.04 LTS

+0.00 LTS

+0.13 LTS

+0.00 LTS

+0.00 LTS

+0.00 LTS

+0.13 LTS

+0.00 LTS

+0.20 LTS

+0.00 LTS

+0.20 LTS

+0.00 LTS

+0.02 015

+31.77 LTS

+0.00 LTS

+0.00 LTS

+0.00 LTS

+0.02 LTS

+0.00 LTS

-0.17 011

+26.03 011

+18.33 011

+8.25 008

+7.32 008

+3.59 007

+34.52 007

+16.50 015

+10.33 009

+18.01 009

+0.54 009

-0.58 009

-0.69 011

-0.71 009

+31.07 TO+38.66 011

+11.97 012

+18.29 005

-0.67 LTS

+21.50 TO+30.40 LTS

-0.11 LTS

-0.09 LTS

+0.00 LTS

+0.02 LTS

+0.11 LTS

+0.11 LTS

+0.02 LTS

+0.02 LTS

+0.50 LTS

+0.09 LTS

+0.65 LTS

+0.16 LTS

+0.63 LTS

+0.11 LTS

+0.63 LTS

+0.11 EXT EXT UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE LTE UTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE UTIL 1 UTIL 2 CAL 26 27 26 46 45 46 45 45 46 46 45 45 98 98 125 125 125 126 125 126 126 115 141 115 141 115 116 115 141 115 116 115 116 115 116 116 115 116 115 116 115 115 115 115 115 115 115 115 115 115 115 115 115 115 115 114 26 27 27 26 27 26 27 26 46 4

4 4

4 4

4 4

4 4

4 LEG OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 510UL 510UL 510UL 51OUL 51OUL 51OUL 51OUL 510UL 51OUL 51OUL 51OUL 510UL 51OUL 51OUL 51OUL 51OUL 510UL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 510UL 51OUL 510UL 51OUL 5lOUL 51OUL 510UL 510UL 510UL 51OUL 510UL 510UL 510UL 51DUL 51OUL 51OUL 51OUL 51OUL 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:14:55 Component: S/G A Page 19 of 56 ATTACHMENT #1 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW TUBE VOLTS 10.50 59 64 15.04 14.12 59 65 6.53 59 67 6.61 59 68 32.88 14.96 6.34 59 71 0.38 59 76 7.42 59 77 13.59 59 78 29.11 59 79 18.23 59 80 23.29 59 82 26.79 59 83 15.53 59 84 9.39 59 85 17.43 59 86 28.88 59 87 21.51 59 88 27.03 59 89 14.26 59 90 11.80 59 91 6.17 59 114 0.30 59 117 0.64 59 120 0.93 59 121 0.48 0.60 59 124 0.63 0.38 60 1

0.99 60 3

0.94 60 18 0.50 60 35 0.31 60 43 6.65 60 47 0.72 60 54 6.73 60 55 8.12 60 56 10.12 60 57 31.34 60 58 24.40 60 59 24.68 60 60 21.71 60 61 33.05 60 62 21.87 60 63 9.96 33.55 60 64 25.02 6.42 60 65 12.90 22.97 60 66 6.28 12.09 60 67 9.47 6.19 60 68 6.90 9.32 60 71 0.36 60 80 0.34 9.46 60 81 14.34 60 82 9.95 60 83 20.91 60 84 31.52 60 85 20.79 60 86 23.71 60 87 16.74 60 88 15.65 60 89 11.22 60 90 29.40 60 91 26.92 60 92 26.63 60 93 20.20 60 94 18.15 DEG 182 176 181 160 166 183 181 163 68 189 175 183 177 184 177 189 175 179 177 182 174 180 177 183 72 122 126 102 80 123 104 97 98 115 88 179 82 177 181 177 180 179 173 173 176 175 176 173 176 177 180 176 186 174 175 187 187 193 103 114 189 177 181 178 190 177 182 176 181 174 190 176 180 173 189 CHN 3

P 1 3

P 1 3

3 3

P1 3

P1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 3

P1 P 1 P 1 3

P1 3

P1 P 1 P 1 3

P P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P1 3

P1 P 1 3

3 P1 3

P1 P 1 3

3 3

3 P1 P 1 P1 P1 P1 P1 P1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 IND %TW LOCATIOI DNT LT'S DNT LTS DNT LTS DNT LTS DNT LTS DNT LTE DNT LTE DNT LTS NQI 007 DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS NTI 009 NQI 009 NQI 009 NQI 010 NQI 009 NQI 011 NQI 010 NQI 012 NQI 011 NQI 015 NQI 012 DNT LTS NQI 003 DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT UTS NQI 006 NQI 005 DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS DNT LTS N

EXT

+0.72 LTE

+0.20 LTE

+0.79 LTE

+0.22 LTE

+0.72 LTE

+1.81 LTE

+2.99 LTE

+0.07 LTE

+28.00 UTE

+0.15 UTE

+0.18 UTE

+0.00 UTE

+0.16 UTE

-0.18 UTE

+0.00 UTE

+0.04 UTE

+0.11 UTE

+0.02 UTE

+0.09 UTE

+0.00 UTE

+0.07 UTE

+0.00 UTE

+0.07 UTE

-0.15 UTE

+28.89 UTE

-0.68 UTE

-0.77 UTE

+0.33 UTE

+18.88 TO+29.75 UTE

-0.67 LTE

+17.16 LTE

+0.66 014

-0.75 014

+0.71 UTE

+31.96 UTE

+0.00 UTE

-0.82 UTE

+0.00 UTE

-0.11 UTE

+0.00 UTE

+0.00 UTE

+0.00 UTE

+0.09 LTE

+0.07 LTE

+0.09 LTE

+0.09 LTE

+0.65 LTE

+0.11 LTE

+0.16 LTE

+0.65 LTE

+0.58 LTE

+0.13 LTE

+0.67 LTE

+0.18 LTE

+0.22 LTE

+0.69 LTE

+0.74 LTE

+11.65 LTE

+24.51 LTE

+0.67 UTE

-0.11 UTE

+0.29 UTE

+0.13 UTE

+0.20 UTE

+0.15 UTE

+0.09 UTE

+0.07 UTE

+0.11 UTE

+0.11 UTE

+0.09 UTE

+0.11 UTE

+0.11 UTE

+0.00 UTE

+0.02 UTE

-0.06 UTE EXT UTE UTE UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTIL 1 UTIL 2

= = = =

CAL 4

4 4

4 4

4 4

4 126 141 115 116 115 116 115 141 115 141 15 116 115 116 115 141 116 115 116 115 11s 114 114 132 132 26 21 21 21 21 22 21 22 21 4

4 4

4 4

4 4

4 4

4 4

4 4

4 4

4 4

141 141 115 141 15 141 115 116 15 141 15 141 115 116 115 141 LEG INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET PROBE 510UL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 510UL 510UL 51OUL 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:14:56 Component: S/G A Page 20 of 56 ATTACHMENT #1 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW 60 60 60 60 60 61 61 61 61 61 61 61 61 61 61 61 61 61 61 61 61 61 61 61 61 61 61 61 61 61 61 61 61 61 61 61 61 61 61 61 61 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 TUBE VOLTS 95 6.68 117 8.63 122 10.50 125 0.71 126 0.58 3

0.60 1.65 4

0.46 0.39 32 0.47 54 10.20 55 16.73 56 17.29 57 0.78 25.97 58 22.03 59 49.19 60 35.28 61 36.35 62 28.63 6.63 63 27.84 64 18.41 7.73 65 9.04 7.71 66 8.00 11.14 67 14.90 9.80 68 6.23 70 6.79 71 0.35 7.73 81 12.00 82 13.07 83 25.84 84 26.09 85 27.98 86 13.58 0.67 87 9.91 88 13.09 89 17.94 90 18.97 91 20.17 92 12.90 98 0.85 0.43 102 0.35 116 0.35 121 0.88 8

0.71 20 0.57 0.47 23 0.45 43 0.30 52 0.73 56 10.87 57 40.91 58 23.93 59 27.69 60 25.69 61 52.01 62 31.02 63 34.82 64 33.54 65 32.92 66 14.34 67 14.01 68 7.88 9.74 70 6.68 72 10.30 7.78 DEG 177 180 178 116 72 115 107 92 96 99 178 179 178 60 174 176 176 175 177 176 175 176 177 181 172 183 173 184 185 194 183 179 61 179 176 175 176 176 177 176 130 174 167 172 172 173 170 59 86 95 96 111 86 112 113 94 100 78 179 180 175 176 176 176 177 177 177 177 176 176 168 181 172 178 179 CHN P 1 3

3 21 P 1 P1 P 1 3

P 1 3

P1 P 1 P1 3

2 1 P 1 2 1 P 1 P 1 2 1 3

P 1 P1 3

P 1 3

P 1 3

3 3

3 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 3

P 1 P 1 33 3

3 P 1 3

3 3

2 1 P1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 2 1 P 1 P 1 3

2 1 2 1 3

IND DNT DNT DNT NQI NQI NQI NQI NQI NQI TWD DNT DNT DNT NQI DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT NQI DNT DNT DNT DNT DNT DNT DNT NQI DNT DNT DNT DNT DNT DNT NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT

%TW LOCATIOI LTS 002 004 009 009 011 013 012 010 33 009 LTS LTS LTS 002 LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS UTS LTS LTS 009 LTS LTS LTS LTS LTS LTS LTS 015 LTS LTS LTS LTS LTS LTS 015 014 006 015 014 010 015 015 015 003 011 LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS N

EXT EXT

-0.11 UTE LTE

+35.77 LTE UTE

+33.38 LTE UTE

-0.62 LTE UTE

-0.67 LTE UTE

-0.70 014 LTE

-0.82 014 LTE

+1.18 014 LTE

+0.39 014 LTE

+16.49 UTE LTE

-0.11 UTE LTE

+0.00 UTE LTE

+0.00 UTE LTE

+2.22 LTE UTE

+0.09 LTE UTE

+0.07 LTE UTE

+0.09 LTE UTE

+0.13 LTE UTE

+0.13 LTE UTE

+0.16 LTE UTE

+0.58 LTE UTE

+0.22 LTE UTE

+0.20 LTE UTE

+0.72 LTE UTE

+0.13 LTE UTE

+0.63 LTE UTE

+0.11 LTE UTE

+0.74 LTE UTE

+0.65 LTE UTE

+14.49 LTE UTE

+0.76 LTE UTE

+0.34 LTE UTE

+0.07 LTE UTE

+0.38 LTE UTE

+0.20 UTE LTE

+0.11 UTE LTE

+0.09 UTE LTE

+0.00 UTE LTE

+0.00 UTE LTE

+0.16 UTE LTE

+0.80 UTE LTE

+0.02 UTE LTE

+0.02 UTE LTE

+0.11 UTE LTE

+0.00 UTE LTE

+0.13 UTE LTE

+0.00 UTE LTE

+9.82 UTE LTE

+14.53 UTE LTE

+28.15 UTE LTE

+14.07 LTE UTE

+1.32 LTE UTE

+0.47 UTE LTE

+36.95 UTE LTE

+35.64 UTE LTE

+35.31 UTE LTE

-0.84 UTE LTE

-0.90 UTE LTE

-0.07 UTE LTE

-0.02 UTE LTE

+0.11 LTE UTE

+0.16 LTE UTE

+0.16 LTE UTE

+0.13 LTE UTE

+0.18 LTE UTE

+0.16 LTE UTE

+0.18 LTE UTE

+0.18 LTE UTE

+0.11 LTE UTE

+0.11 LTE UTE

+0.11 LTE UTE

+0.69 LTE UTE

+0.20 LTE UTE

+0.40 LTE UTE

+0.92 LTE UTE UTIL 1 UTIL 2 CAL # LEG 115 OUTLET 114 INLET 114 INLET 114 INLET 114 INLET 132 OUTLET 132 OUTLET 133 OUTLET 133 OUTLET 21 OUTLET 22 OUTLET 21 OUTLET 21 OUTLET 4

INLET 4

INLET 4

INLET 4

INLET 4

INLET 4

INLET 4

INLET 4

INLET 4

INLET 4

INLET 4

INLET 4

INLET 4

INLET 4

INLET 4

INLET 4

INLET 4

INLET 4

INLET 4

INLET 4

INLET 4

INLET 119 OUTLET 119 OUTLET 119 OUTLET 119 OUTLET 119 OUTLET 119 OUTLET 119 OUTLET 119 OUTLET 119 OUTLET 119 OUTLET 119 OUTLET 119 OUTLET 119 OUTLET 119 OUTLET 119 OUTLET 119 OUTLET 114 INLET 114 INLET 21 OUTLET 21 OUTLET 21 OUTLET 22 OUTLET 17 OUTLET 18 OUTLET 18 OUTLET 17 OUTLET 4

INLET 4

INLET 4

INLET 4

INLET 4

INLET 4

INLET 4

INLET 4

INLET 4

INLET 4

INLET 4

INLET 4

INLET 4

INLET 4

INLET 4

INLET PROBE 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 510UL 510UL 510UL 510UL 510UL 510UL

-510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 51OUL 510UL 51OUL 510UL 51OUL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 51OUL 510UL SlOUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 5lOUL 51OUL 51OUL 51OUL 51OUL 51OUL SO1UL 51OUL S5OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 ATTACHMENT #1 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl 12/05/01 14:14:56 Component: S/G A Page 21 of 56 ROW 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 63 63 63 63 63 63 63 63 63 63 63 63 63 63 63 63 63 63 63 63 63 63 63 63 63 63 63 63 63 63 63 63 63 63 63 63 63 63 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 TUBE 75 79 84 85 86 87 88 89 90 91 92 93 94 95 115 125 126 1

2 4

10 21 22 25 34 54 56 57 58 59 60 61 62 63 64 65 66 67 68 69 72 73 74 86 87 88 89 90 91 92 93 94 95 96 122 2

10 12 16 43 48 56 57 58 59 60 61 62 63 64 VOLTS 0.33 0.18 7.51 14.39

32. 06 37.49 24.41 23.29 18.27 20.65 16.80 22.06 13.55 23.02 0.87 0.56 0.53 0.28 0.59 2.27 0.47 0.42 0.50
1. 65 1.23 15.25 0.36 9.04 34.32 35.46 0.42 29.64 39.22 45.82 0.18 38.88 29.39 38.58 37.44 27.49 26.00 14.19 10.30 6.20 8.41 8.09 13.26 28.21 49.66 36.67 0.34 18.33
7. 61 13.70 23.36
32. 64 15.21 12.30 0.48 1.15 0.50 0.31 0.56
0. 60 0.50 0.80 0.37 11.79 37.23 35.26 32.20 32.30 42.02 30.77 38.03 DEG CHN IND %TW LOCATION 96 3

NQI 006

+26.53 99 P 1 NQI 005

-0.58 172 P 1 DNT LTS

+0.07 174 P 1 DNT LTS

+0.00 176 P 1 DNT LTS

+0.04 176 P 1 DNT LTS

+0.00 184 P 1 DNT LTS

+0.11 183 P 1 DNT LTS

+0.09 181 P 1 DNT LTS

+0.14 178 P 1 DNT LTS

+0.09 181 P 1 DNT LTS

+0.14 182 P 1 DNT LTS

+0.20 181 P 1 DNT LTS

+0.11 182 P 1 DNT LTS

+0.09 61 3

NQI 003

+32.65 110 3 NQI 009

+26.84 68 P 1 NQI 009

-0.63 105 P 1 NQI 011

+0.04 82 P 1 NQI 012

+0.66 96 P 1 NQI 012

+0.75 79 P 1 NQI 001

-0.90 97 3

NQI 003

+17.51 85 3

NQI 002

+13.05 52 6

ADI 015

+35.54 56 6

ADI 015

+34.42 88 6

ADI LTS

+21.82 TO+30.24 97 3

NQI 011

+21.63 179 P 1 DNT LTS

+0.07 180 P 1 DNT LTS

+0.04 179 P 1 DNT LTS

+0.13 98 P 1 NQI 002

-0.84 176 P 1 DNT LTS

+0.13 176 P 1 DNT LTS

+0.13 177 P 1 DNT LTS

+0.18 94 P 1 NQI 014

+0.16 177 P 1 DNT LTS

+0.13 175 P 1 DNT LTS

+0.13 176 P 1 DNT LTS

+0.11 177 P 1 DNT LTS

+0.18 176 P 1 DNT LTS

+0.18 176 P 1 DNT LTS

+0.16 174 P 1 DNT LTS

+0.13 172 P 1 DNT LTS

+0.20 176 P 1 DNT LTS

+0.32 182 P 1 DNT LTS

+0.56 181 P 1 DNT LTS

+0.51 183 P 1 DNT LTS

+0.09 179 P 1 DNT LTS

+0.09 183 P 1 DNT LTS

+0.07 183 P 1 DNT LTS

+0.16 72 3

NQI 012

+10.52 181 P 1 DNT LTS

+0.09 178 P 1 DNT LTS

+0.14 177 P 1 DNT LTS

+0.00 181 P 1 DNT LTS

+0.18 183 P 1 DNT LTS

+0.20 182 P 1 DNT LTS

+0.07 180 P 1 DNT LTS

+0.02 82 P 1 NQI 007

+0.72 97 P 1 NQI 011

+0.57 72 P 1 NQI 014

+1.04 102 3 NQI LTS

+8.88 122 3 NQI UTS

-0.49 114 3 NQI 015

+36.39 97 3

NQI 015

+24.33 74 3

NQI 008

+28.52 95 P 1 NQI 004

-0.91 181 P 1 DNT LTS

-0.11 181 P 1 DNT LTS

-0.04 175 P 1 DNT LTS

+0.11 177 P 1 DNT LTS

+0.20 176 P 1 DNT LTS

+0.23 179 P 1 DNT LTS

+0.25 177 P 1 DNT LTS

+0.18 177 P 1 DNT LTS

+0.18 EXT EXT UTIL 1 UTIL 2 CAL # LEG UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 014 014 014 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 014 014 UTE UTE UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE 119 119 119 119 119 119 114 114 114 114 114 114 114 114 114 110 110 132 133 132 18 17 17 18 17 18 17 17 18 17 17 4

4 4

4 4

4 4

4 4

4 4

4 4

4 125 120 119 120 114 114 114 114 114 114 114 114 114 110 132 132 17 17 17 18 17 17 18 17 4

4 4

4 4

4 OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET PROBE 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 5lOUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:14:56 Component: S/G A Page 22 of 56 ATTACHMENT #1 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW TUBE 64 65 64 66 64 67 64 68 64 69 64 70 64 71 64 72 64 73 64 74 64 75 64 78 64 87 64 88 64 89 64 90 64 91 64 92 64 93 64 94 64 95 64 96 64 126 65 3

65 13 65 18 65 23 65 27 65 38 65 40 65 43 65 50 65 58 65 59 65 60 65 61 65 62 65 63 65 64 65 65 65 66 65 67 65 68 65 69 65 71 65 72 65 73 65 85 65 87 65 88 65 89 65 90 65 91 65 92 65 93 65 94 65 95 65 96 65 125 65 126 66 3

66 18 66 26 66 45 66 59 66 60 66 61 66 62 66 63 66 64 66 65 66 66 66 67 VOLTS 47.71 61.71 39.82 39.04 35.91

12. 62 9.12 17.98 16.56 7.55 6.36 1.54 13.66 35.47 36.96 27.09
17. 67 14.07 14.50 31.36 37.34 16.71 0.85 0.29 0.70 0.30
0. 61 0.29 0.29 2.25 0.55
0. 68 0.50 25.28 47.40 32.29 60.25 70.26 26.80 33.06 55.31 35.21 42.00 40.96 27.26 35.89 57.75 29.31 6.80 13.30 29.73 32.01 37.16 19.81
15. 61 17.34 37.41 32.86 8.76 1.00 0.54 0.50 0.44 32.14 0.44 0.37 26.25 45.54 50.30 56.65 36.94 29.04 32.97 37.31 28.46 DEG 177 177 177 176 176 172 168 173 173 177 179 106 185 178 183 177 182 172 181 181 181 178 109 99 105 99 97 90 85 115 136 79 94 181 176 176 178 178 175 176 177 176 176 177 175 176 176 175 184 184 184 182 182 179 173 181 180 181 181 112 111 64 130 109 107 97 175 176 176 177 177 177 176 176 176 CHN P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 3P 1

P 1 3P 1 3

3 3

P 1 3

P 1 P 1 P1I P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P1 3

P1 P 1 P1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 3

P 1 P 1 3

P 1 P 1 P 1 P1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 IND

=NT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT NQT NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT NTI NQI NQI NQI NQI NQI NQI INT DNT DNT DNT DNT DNT DNT DNT DNT

%TW LOCATION LTS LTS A

LTS

+

LTS

+

LTS

+

LTS A

LTS A

LTS A

LTS A

LTS A

LTS

+

UTS A

LTS A

LTS A

LTS A

LTS A

LTS A

LTS A

LTS A

LTS LTS LTS A

009 014 A

013 004 004 LTS A

012 A

LTS 4

007 4

006 A

010 4

LTS 4

LTS 4

LTS 4

LTS 4

LTS

+

LTS 4

LTS 4

LTS

+

LTS 4

LTS

+

LTS

+

LTS

+

LTS

+

LTS

+

LTS

+

LTS 4

LTS

+

LTS

+

LTS

+

LTS 4

LTS 4

LTS

+

LTS

+

LTS

+

LTS LTS 4

008 013 4

010 4

011 LTS 4

010 4

006 4

LTS 4

LTS 4

LTS 4

LTS 4

LTS 4

LTS 4

LTS 4

LTS 4

LTS 4

-0.16

-0.20

-0.18

-0.18

-0.20

-0.16

-0.13

-0.18

-0.29

-0.54

-0.42

-20.04

-0.20

-0.00

-0.09

-0.00

-0.04

-0.09

-0.11

-0.18

-0.09

-0.02

-0.65

-1.20

-0.81

-0.80

-0.79

-30.58

+32.98

+22.00 TO+30.31

-16.21

-0.67

-28.40

+0.00 0.14

+0.16

+0.18

+0.18

+0.16 0.14

+0.14 0.18 0.16 0.16

+0.20

+0.16 0.18 0.20 0.75 0.13

+0.13 0.09 0.07

+0.11 0.11 0.13

+0.15 0.04

+0.04 0.56

+31.22

0. 62 0.75

+22.15 TO+29.89

+0.47

+0.56

+0.07

  • 0.11 0.14
  • 0.

11

  • 0.

11

+0.14 0.14

+0.09

+0.16 EXT EXT LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE LTE UTE LTE UTE LTE UTE LTE UTE 014 LTE 014 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE LTE UTE LTE UTE LTE UTE LTE UTE 014 LTE 014 LTE UTE LTE UTE LTE UTE LTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE UTIL 1 UTIL 2

==

CAL #

4 4

4 4

4 4

4 4

4 4

119 119 120 119 120 119 120 119 120 110 110 110 110 133 133 17 18 17 17 18 18 17 18 17 4

4 4

4 4

4 4

4 4

4 4

4 4

4 120 120 120 120 120 120 120 120 120 110 110 110 110 132 132 17 17 18 4

4 4

4 4

4 4

4 4

LEG PROBE INLET 51OUL INLET 51OUL INLET 51OUL INLET 51OUL INLET 51OUL INLET 51OUL INLET 51OUL INLET 51OUL INLET 51OUL INLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL INLET 51OUL INLET 51OUL INLET 51OUL INLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL INLET 51OUL INLET 51OUL INLET 51OUL INLET 51OUL INLET 51OUL INLET 51OUL INLET 51OUL INLET SlOUL INLET 51OUL INLET 51OUL INLET 51OUL INLET 51OUL INLET 51OUL INLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET SlOUL OUTLET 51OUL OUTLET 51OUL INLET 51OUL INLET 51OUL INLET 51OUL INLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL INLET 51OUL INLET 51OUL INLET 51OUL INLET 51OUL INLET 51OUL INLET 51OUL INLET 51OUL INLET 51OUL INLET 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:14:56 Component: S/G A Page 23 of 56 ATTACHMENT #1 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW 66 66 66 66 66 66 66 66 66 66 66 66 66 66 66 66 66 66 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 68 68 68 68 68 68 68 68 68 68 TUBE VOLTS 68 21.37 69 22.28 70 18.74 71 48.22 72 74.20 74 31.47 88 9.71 89 40.65 90 34.41 91 31.37 92 13.54 93 20.66 94 21.77 95 37.88 96 22.16 97 7.39 103 0.37 126 0.70 0.50 2

0.62 7

0.65 11 0.76 15 0.36 18 0.27 22 0.66 26 0.41 0.55 28 0.31 37 0.53 54 0.50 56 0.52 59 10.05 60 31.76 61 52.20 62 46.98 63 29.96 64 35.45 65 34.47 66 15.45 67 14.60 68 15.75 0.42 69 22.28 70 43.57 71 87.62 72 73.50 73 46.91 74 6.40 88 11.67 89 21.10 90 53.91 91 28.26 92 19.61 93 20.71 94 29.88 95 40.17 96 20.18 97 10.57 105 0.33 124 0.43 129 0.45 130 0.41 2

0.75 1.06

0. 9 1 5

1.36 6

0.62 8

0.59 11 0.40 12 0.71 13 0.62 0.54 17 0.74 20 1.06 23 0.71 DEG 176 173 172 175 176 177 179 182 184 182 177 179 180 182 179 179 129 100 96 118 105 24 97 92 115 109 97 100 73 116 87 176 175 177 176 174 174 177 176 175 175 67 173 176 176 176 176 169 184 178 182 176 180 176 180 182 178 179 73 81 99 53 109 130 103 107 108 106 83 116 78 114 86 115 144 CHN P=1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P1 P 1 P 1 3

P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 3

P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 3

P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 31 P 1 P21 3

P1 3

P 1 3

P 1 P 1 P 1 P 1 P 1 P 1 P 1 31 P 1 3

P21 P 1 IND

=NT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI BNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI

%TW LOCATION LTS

+0.14 LTS

+0.11 LTS

+0.11 LTS

+0.16 LTS

+0.18 LTS

+0.18 LTS

+0.15 LTS

+0.11 LTS

+0.13 LTS

+0.09 LTS

+0.11 LTS

+0.02 LTS

+0.11 LTS

-0.07 LTS

-0.02 LTS

-0.18 015

+32.78 008

+0.74 008

-0.67 011

-0.66 004

-0.79 012

+0.74 011

+0.18 010

+0.73 011

+0.55 006

-0.87 009

+0.54 012

+19.26 009

+0.68 UTS

+18.72 UTS

+15.80 LTS

+0.07 LTS

+0.11 LTS

+0.09 LTS

+0.07 LTS

+0.07 LTS

+0.11 LTS

+0.07 LTS

+0.05 LTS

+0.07 LTS

+0.00 015

+10.30 LTS

+0.04 LTS

-0.24 LTS

+0.13 LTS

+0.18 LTS

+0.18 LTS

+0.29 LTS

+0.22 LTS

+0.07 LTS

+0.11 LTS

+0.00 LTS

+0.07 LTS

+0.00 LTS

+0.09 LTS

+0.18 LTS

-0.24 LTS

+0.18 008

+29.93 007

-0.28 012

+1.43 011

+0.20 013

+14.23 011

-0.68 011

+0.62 010

+0.59 010

+0.51 010

-0.59 010

-0.76 010

-0.73 010

-0.79 011

+0.56 007

+6.34 008

-0.67 010

-0.73 EXT LTE LTE LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE 014 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE 014 014 014 014 014 UTE UTE UTE UTE UTE UTE UTE UTE EXT UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTIL 1 UTIL 2 CAL #

4 4

4 4

4 4

120 120 120 120 120 120 120 110 110 110 110 110 110 133 18 17 18 17 17 17 17 17 18 17 17 4

4 4

4 4

4 4

4 4

4 4

4 4

4 4

4 4

120 122 120 122 120 122 120 110 110 110 110 110 110 110 132 132 132 133 132 18 17 18 17 17 18 17 18 LEG INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET PROBE 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 510UL 51OUL 51OUL 510UL 510UL 51OUL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 51OUL 510UL 510UL 510UL 5lOUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 510UL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:14:56 Component: S/G A Page 24 of 56 ATTACHMENT #1 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 69 69 69 69 69 69 69 69 69 69 69 69 69 69 69 69 69 69 69 69 69 69 69 69 69 69 69 69 69 70 70 70 70 70 TUBE 60 62 63 64 65 66 70 71 72 73 74 89 90 91 92 93 95 96 100 110 117 127 129 130 131 6

8 12 14 15 17 23 37 41 43 44 46 55 57 62 72 73 74 75 78 90 91 92 93 94 95 96 97 118 3

7 8

9 10 VOLTS 6.27 18.26 14.80 9.73 11.46 0.61 0.80 7.06 9.36 42.59 39.50 29.76 10.77 41.83 43.42 27.52 15.90 34.47 37.90 0.57 0.70 1.44 0.59 0.80

0. 67 0.51 0.73 0. 90 0.52
0. 63 0.33 0.50 0.41 1.26 0.54 0.54 0.32 0.46 0.29 0.54 0.57 0.53
0. 64 0.43 0.24 0.41 0.41 15.38
0. 32 29.22 16.33 9.21 8.00 0.45 0.41 0.36 23.88 53.11 44.95 33.51 24.17 24.73 61.51 29.92 0.23 0.43 1.25 0.47 0.53
0. 65 0.30 0.41
0. 65 0.52 0.35 DEG 188 178 179 177 177 91 88 179 179 176 175 175 184 180 182 177 180 177 181 68 96 88 78 114 90 80 94 110 70 114 100 86 117 108 67 108 106 96 91 31 44 75 68 71 89 88 53 178 82 176 172 183 167 76 96 92 184 180 181 180 180 177 182 177 108 92 95 75 108 87 114 115 87 68 48 CHN 3

P 1 P 1 P 1 P 1 3

P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P1 P 1 P 1 P 1 3

P 1 P 1 P 1 P 1 3

P 1 3

P 1 3

P 1 P1 3

3 P1 3

P I P 1 P 1 P 1 P 1 P 1 P 1 3

P 1 P 1 P 1 P 1 P 1 P 1 3

P 1 3

3 3

P 1 P 1 P 1 P 1 P 1 P 1 P 1 P1 3

P 1 P 1 3

3 P 1 P 1 P 1 P 1 3

P 1 IND %TW LOCATION DNT LTE A

DNT LTS A

DNT LTS A

DNT LTS DNT LTS A

NQI 002 A

NQI 004 A

DNT LTS A

DNT LTS A

DNT LTS A

DNT LTS A

DNT LTS A

DNT LTS A

DNT LTS A

DNT LTS A

DNT LTS A

DNT LTS A

DNT LTS A

DNT LTS A

NQI 015 A

NQI 006 A

NQI 014 A

NQI 008 A

NQI 008 NQI 007 A

NQI 012 A

NQI 011 NQI 014

+

NQI 009 NQI 010 A

NQI 011 A

NQI 010 A

TWD 1 UTS TWD 16 015 A

NQI 008 NQI 010 A

TWD 20 001 A

NQI 011 A

NQI 008 A

NQI 008 A

NQI 006 A

NQI 006 A

NQI 009 NQI 006 4

NQI 002 A

NQI UTS A

NQI 006 A

DNT LTS A

NQI 010 A

DNT LTS DNT LTS 4

DNT 009 4

DNT LTS A

NQI 013 A

NQI 014 A

NQI 010 4

DNT LTS A

DNT LTS A

DNT LTS

+

DNT LTS

+

DNT LTS A

DNT LTS

+

DNT LTS A

DNT LTS

+

NQI 015 A

NQI 011

+

NQI 011 NQI 011

+

TWD 16 011 A

NQI 010 A

NQI 013 NQI 011 A

NQI 010 A

NQI 011 A

NQI 009

+

-22.10

-0.09

-0.14

-0.02

-0.00

-25.64

-0.75

-0.11

-0.07

-0.11

-0.13

-0.22

-0.15

-0.00

-0.07

-0.00

-0.11

-0.09

-0.09

-0.68

-11.22

-0.91

-0.77

-0.61

-0.68

-1.35

-0.29

-32.47

-0.61

-33.97

-1.08

-0.61

-0.47

-1.54

-0.74

-10.20

-16.66

-0.42

-0.51

-0.67

-0.

67

-0.

62

-0.80

-0.62

-12.84

-17.28

-0.75

-0.04

-0.52

-0.37

-0.07

-21.97

-0.09

-6.66

-24.24

-14.74

-0.17

-0.00

-0.13

-0.00

-0.15

-0.00

-0.09

-0.04

-2.87

-0.38

-0.26

-11.21

-4.09

-0.38

-0.81

-0.70

-0.51

-7.14

-0.61 EXT LIE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 014 014 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE 014 014 014 014 014 014 014 014 UTE UTE EXT UTIL 1 UTIL 2 DIE UTE UTE iUTE iUTE iUTE iUTE iUTE iUTE iUTE iUTE iUTE LTE LTE LTE LTE LTE LTE LTE iTE iUTE iUTE iUTE iUTE iUTE iUTE iUTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE ITE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE CAL #

2 2

2 2

2 2

2 2

4 4

4 4

120 122 120 122 120 122 120 111 111 110 110 110 110 110 110 110 110 132 132 13 18 17 17 17 17 17 17 17 17 17 17 18 17 17 2

2 2

2 2

2 2

120 120 120 120 122 120 122 120 122 120 122 103 133 133 133 132 132 133 133 132 13 13 LEG INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET PROBE 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL S5OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 510UL 510UL 510UL 51OUL 51OUL 51OUL 51OUL 510UL 51OUL 510UL 510UL 51OUL 51OUL 51OUL 510UL 510UL 51OUL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 51OUL 51OUL 510UL 510UL 51OUL 51OUL 510UL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:14:57 Component: S/G A Page 25 of 56 ATTACHMENT #1 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW TUBE VOLTS 70 11 0.74 0.82 70 12 1.14 70 13 0.47 1.05 70 16 0.32 70 18 0.46 70 22 0.88 70 24 0.32 0.50 70 29 6.58 70 30 0.43 70 32 0.44 70 33 6.11 70 35 8.02 0.44 70 36 7.44 70 40 0.67 70 43 0.54 0.61 70 45 0.64 70 46 0.37 0.46 0.58 70 53 0.47 70 66 0.90 70 67 0.50 70 72 9.62 70 73 12.92 70 75 7.17 70 89 6.36 70 90 28.15 0.36 70 91 51.46 70 92 57.39 70 93 0.40 34.86 70 94 27.17 70 95 26.51 11.20 7.89 16.79 23.81 22.38 11.73 12.32 70 96 41.05 70 97 15.92 70 100 0.28 0.27 70 103 0.25 70 119 0.37 70 124 0.82 0.66 70 128 0.78 71 3

0.43 0.33 71 9

0.71 0.38 0.53 71 12 0.86 0.36 71 13 0.94 0.60 71 14 0.86 0.49 71 15 0.48 71 17 0.63 0.30 71 18 0.36 71 19 0.97 71 21 1.03 0.57 71 23 0.76 71 28 0.75 DEG CHN IND 112 3 NQI 130 3 NQI 104 P 1 NQI 87 P 1 NQI 131 3 NQI 112 P 1 NQI 107 P 1 NQI 95 P 1 NQI 97 P 1 NQI 82 P 1 NQI 182 P 1 DNT 99 P 1 NQI 103 3 NQI 181 P 1 DNT 182 P 1 DNT 91 P 1 NQI 177 P 1 DNT 55 P 1 NQI 91 P 1 NQI 104 P 1 NQI 89 P 1 NQI 97 P 1 NQI 84 P 1 NQI 79 P 1 NQI 78 P 1 NQI 58 P 1 NQI 111 P 1 NQI 178 P 1 DNT 175 P 1 DNT 170 P 1 DNT 182 P 1 DNT 180 P 1 DNT 80 3

NQI 184 P 1 DNT 178 P 1 DNT 76 P 1 NQI 182 P 1 DNT 173 P 1 DNT 180 P 1 DNT 181 3 DNT 182 3 DNT 182 3 DNT 181 3 DNT 178 3 DNT 178 3 DNT 183 3 DNT 177 P 1 DNT 182 P 1 DNT 107 3 TWD 99 3

TWD 88 3

NQI 80 3

NQI 92 3

NQI 95 3

NQI 96 P 1 NQI 88 P 1 NQI 87 P 1 NQI 92 P 1 NQI 79 P 1 NQI 103 3 NQI 112 P 1 NQI 92 P 1 NQI 112 P 1 NQI 89 P 1 NQI 103 P 1 NQI 105 3 NQI 98 P 1 NQI 107 P 1 NQI 83 P 1 NQI 83 P 1 NQI 92 P 1 NQI 112 3 NQI 122 P 1 NQI 103 P 1 NQI 123 P 1 NQI

%TW LOCATION 011

+34.15 012

-1.13 013

-0.74 011

+0.49 012

-1.14 011

+0.36 015

-0.87 011

+0.42 012

-0.11 003

-0.64 UTS

+0.00 011

+0.49 010

+4.17 UTS

+0.04 UTS

+0.00 006

-0.87 UTS

+0.00 009

-0.67 008

+0.69 009

-0.74 009

-0.78 009

+0.67 009

-0.71 008

-0.67 005

+0.50 005

+0.66 005

+0.72 LTS

+0.00 LTS

+0.09 LTS

+0.07 LTS

+0.09 LTS

+0.16 LTS

+24.83 LTS

+0.18 LTS

+0.09 015

-0.87 LTS

+0.09 LTS

+0.09 LTS

+0.18 LTE

+9.83 LTE

+4.56 LTE

+3.88 LTE

+3.11 LTE

+2.74 LTE

+2.47 LTE

+1.84 LTS

+0.02 LTS

+0.00 12 010

+12.16 28 010

+21.77 010

+2.97 008

+30.55 002

+9.88 002

+34.39 008

-0.50 013

-0.55 010

-0.34 011

+0.73 011

+0.40 011

+35.66 014

-0.67 010

+0.25 014

-0.80 010

+0.42 015

-0.77 015

+28.39 014

-0.76 015

-0.76 008

+0.62 008

+0.67 012

-1.00 012

+2.32 010

+0.40 011

+0.53 012

+0.54 EXT UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE 014 014 014 014 014 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE EXT LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTIL 1 UTIL 2 CAL 14 14 13 14 14 14 14 14 14 14 13 14 14 13 13 13 14 14 13 13 13 14 14 14 13 2

2 2

2 2

120 122 122 120 122 120 120 122 120 120 120 120 120 120 120 120 122 120 104 104 103 104 103 103 103 133 133 133 133 133 13 13 14 14 13 13 14 14 14 13 14 14 14 14 13 4 LEG OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET PROBE 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:14:57 Component: S/G A Page 26 of 56 ATTACHMENT #1 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW TUBE VOLTS 0.42 71 29 0.13 71 30 0.51 7.18 71 33 0.76 71 36 0.61 71 40 0.42 71 45 0.52 71 46 0.44 0.92 1.21 71 48 0.56 71 54 0.62 71 60 0.95 0.34 71 71 6.05 0.47 71 72 9.78 71 73 13.54 71 74 8.41 71 75 7.85 71 89 11.30 71 90 36.30 71 91 47.57 71 92 53.61 71 93 40.11 71 94 19.62 71 95 6.33 42.01 71 96 0.41 29.90 71 101 0.65 71 106 26.52 25.20 71 119 0.35 71 128 0.51 0.27 71 130 9.66 71 131 0.46 1.61 13.33 72 9

1.18 72 13 0.42 72 23 1.04 72 24 0.74 72 25 0.97 72 27 0.61 72 28 0.79 72 31 0.62 72 32 6.03 0.64 72 34 0.43 72 35 6.92 0.33 72 39 0.65 72 44 6.20 72 53 0.50 0.30 72 58 0.26 72 64 0.33 72 67 6.30 72 69 9.49 72 70 0.48 72 72 14.07 0.28 0.34 0.44 0.20 0.24 0.38 0.45 0.52 0.67 0.51 0.69 DEG CHN 77 P 1 77 P 1 108 P 1 183 P 1 72 P 1 109 P 1 100 P 1 84 P 1 71 P 1 121 P 1 127 P 1 84 P 1 68 P 1 75 3

99 3

180 P 1 106 3 176 P 1 175 P 1 171 P 1 173 P 1 180 P 1 179 P 1 182 P 1 179 P 1 181 P 1 174 P 1 180 3 180 P 1 113 3 178 P 1 83 3

180 3 177 3 101 3 107 P 1 71 3

13 P 1 86 3

59 6

17 P 1 88 6

56 P 1 106 3 121 P 1 102 P 1 130 3 97 3

107 P 1 178 P 1 83 P 1 97 P 1 177 P 1 102 P 1 115 P 1 180 P 1 114 P 1 58 P 1 108 3 98 P 1 183 P 1 185 3 108 P 1 179 P 1 69 3

55 3

73 3

92 3

84 3

99 3

60 3

85 3

68 3

41 3

77 3

IND %TW LOCATION EXT EXT NOT 013

+0.65 UTE LTE NQI 013

+0.27 UTE LTE NQI 012

+0.47 UTE LTE DNT UTS

+0.00 UTE LTE NQI 012

+0.49 UTE LTE NQI 011

+0.53 UTE LTE NQI 009

+0.43 UTE LTE NQI 008

+0.60 UTE LTE NQI 006

+0.63 UTE LTE NQI 007

-0.67 UTE LTE NQI 008

-0.71 UTE LTE NQI 009

-0.76 UTE LTE NQI 005

+0.58 UTE LTE NQI 001

+33.93 LTE UTE NQI 001

+17.24 LTE UTE DNT LTS

+0.04 LTE UTE TWD 22 010

+24.12 LTE UTE DNT LTS

+0.02 LTE UTE DNT LTS

+0.07 LTE UTE DNT LTS

+0.09 LTE UTE DNT LTS

+0.18 LTE UTE DNT LTS

+0.09 UTE LTE DNT LTS

+0.18 UTE LTE DNT LTS

+0.09 UTE LTE DNT LTS

+0.00 UTE LTE DNT LTS

+0.09 UTE LTE DNT LTS

+0.13 UTE LTE DNT 015

+31.76 UTE LTE DNT LTS

+0.13 UTE LTE NQI 013

+14.58 UTE LTE DNT LTS

-0.02 UTE LTE NQI 010

+31.74 LTE UTE DNT 004

+32.95 LTE UTE DNT 004

+37.28 LTE UTE TWD 24 001

+8.83 LTE UTE NQI 008

-0.53 LTE UTE NQI 013

+26.72 LTE UTE BLG UTS

-0.07 LTE UTE NQI 014

+33.16 LTE UTE ADI 015

+31.27 LTE UTE NQI UTS

+0.00 LTE UTE ADI LTS

+23.85 TO+29.63 014 LTE NQI 014

+0.37 014 LTE NQI 015

+22.64 UTE LTE NQI 015

+0.56 UTE LTE NQI 013

+0.47 UTE LTE NQI 015

+21.44 UTE LTE NQI 012

+8.50 UTE LTE NQI 012

+0.11 UTE LTE DNT UTS

+0.04 UTE LTE NQI 010

+0.36 UTE LTE NQI 015

-0.45 UTE LTE DNT UTS

-0.07 UTE LTE NQI 015

-0.56 UTE LTE NQI 012

+0.51 UTE LTE DNT UTS

+0.00 UTE LTE NQI 007

-0.71 UTE LTE NQI 005

-0.94 UTE LTE NQI 012

+14.74 UTE LTE NQI 003

-0.38 LTE UTE DNT UTS

+0.07 LTE UTE DNT 002

+23.21 LTE UTE NQI 005

+0.61 LTE UTE DNT LTS

+0.02 LTE UTE NQI 009

+9.81 LTE UTE NQI 009

+6.18 LTE UTE NQI 009

+12.06 LTE UTE NQI 009

+24.30 LTE UTE NQI 009

+3.23 LTE UTE NQI 009

+1.29 LTE UTE NQI 008

+29.90 LTE UTE NQI 008

+16.07 LTE UTE NQI 008

+18.06 LTE UTE NQI 008

+32.07 LTE UTE NQI 008

+35.64 LTE UTE UTIL 1 UTIL 2 CAL #

13 14 13 13 14 14 14 14 13 13 13 13 13 2

2 2

2 2

2 2

2 120 122 120 122 120 122 120 120 122 122 104 103 103 104 104 104 104 110 110 110 132 132 14 13 14 14 13 14 13 13 13 14 14 14 13 13 13 14 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 LEG OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 5lOUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 5lOUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:14:57 Component: S/G A Page 27 of 56 ATTACHMENT #1 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW TUBE VOLTS 0.38 0.44 72 73 11.19 72 74 8.78 72 75 7.34 72 79 0.62 72 87 10.78 72 88 6.91 72 89 14.01 72 90 49.48 72 91 53.20 72 92 66.92 72 93 36.61 72 94 24.82 72 95 60.26 72 96 25.61 72 97 8.30 72 123 0.74 72 127 0.53 0.79 72 128 1.52 73 2

0.59 73 4

0.96 73 5

1.57 73 16 0.29 73 46 0.63 73 48 0.57 73 50 0.51 73 65 1.05 73 66 10.21 0.37 73 70 0.27 73 73 11.54 73 74 8.44 73 75 6.69 73 79 0.44 73 88 22.53 73 89 7.75 42.35 73 90 60.41 73 91 55.53 73 92 64.21 73 93 22.44 73 94 44.28 16.34 73 95 27.66 73 96 14.60 73 98 1.06 73 102 0.40 73 120 0.29 73 126 15.51 73 128 0.85 73 129 0.46 74 3

19.98 74 11 0.34 74 19 0.27 74 44 1.00 74 48 6.42 0.78 74 54 2.98 74 59 8.21 14.62 6.77 74 66 0.32 0.41 74 68 19.66 74 69 12.25 74 70 7.81 0.29 74 83 7.18 74 84 15.46 74 85 33.62 74 86 55.49 74 87 69.12 74 88 48.80 DEG CHN IND %TW LOCATION 86 3

NQI 007

+37.77 89 3

NQI 007

+28.36 173 P 1 DNT LTS

+0.07 159 P 1 DNT LTS

+0.18 172 P 1 DNT LTS

+0.25 89 3

NQI 014

+29.64 178 3 DNT LTS

+0.76 179 3 DNT LTS

+0.77 179 P 1 DNT LTS

+0.20 184 P 1 DNT LTS

+0.22 181 P 1 DNT LTS

+0.00 182 P 1 DNT LTS

+0.11 178 P 1 DNT LTS

+0.00 180 P 1 DNT LTS

+0.04 179 P 1 DNT LTS

+0.00 181 P 1 DNT LTS

+0.07 178 P 1 DNT LTS

+0.00 97 P 1 NQI 014

+0.87 91 P 1 NQI 007

-0.53 123 P 1 NQI 008

-0.66 104 P 1 NQI 008

-0.61 111 P 1 NQI 004

+0.78 90 P 1 NQI 013

-0.44 94 P 1 NQI 014

-0.85 84 P 1 NQI 009

+0.31 105 P 1 NQI 010

+0.53 81 P 1 NQI 009

+0.49 107 P 1 NQI 009

+0.54 110 4 TWD 11 014

+5.59 13 P 1 NQI LTE

+4.19 81 3

NQI LTS

+30.89 74 P 1 NQI 009

+0.70 172 P 1 DNT LTS

-0.37 170 P 1 DNT LTS

+0.09 173 P 1 DNT LTS

+0.13 107 3 NQI 006

+23.16 183 P 1 DNT LTS

+0.33 178 3 DNT LTS

+1.08 181 P 1 DNT LTS

+0.04 182 P 1 DNT LTS

+0.20 181 P 1 DNT LTS

+0.11 181 P 1 DNT LTS

+0.11 176 P 1 DNT LTS

+0.00 182 P 1 DNT LTS

+0.15 181 3 DNT LTE

+5.79 177 P 1 DNT LTS

+0.00 178 P 1 DNT LTS

+0.13 71 3

NQI LTS

+38.99 82 3

NQI 013

+20.41 74 3

NQI 014

+21.72 182 3 DNT UTS

+16.75 116 P 1 NQI 008

-0.58 88 P 1 NQI 003

-0.69 181 3 DNT LTE

+11.02 103 3 NQI 007

+24.81 116 P 1 NQI 009

-0.29 34 P 1 NQI UTS

+0.15 181 P 1 DNT UTS

+0.00 97 3

NQI 001

+17.36 116 3 NQI LTS

+21.35 TO+37.92 185 P 1 DNT LTE

+3.13 183 P 1 DNT LTE

+5.63 184 P 1 DNT UTS

+0.05 85 3

NQI UTS

-0.50 82 3

NQI 015

+26.13 176 P 1 DNT LTS

+0.02 173 P 1 DNT LTS

+0.09 172 P 1 DNT LTS

+0.11 99 3

NQI 008

+17.65 175 P 1 DNT LTS

+0.22 183 P 1 DNT LTS

+0.31 182 P 1 DNT LTS

+0.31 182 P 1 DNT LTS

+0.18 179 P 1 DNT LTS

+0.11 181 P 1 DNT LTS

+0.02 EXT LTE LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE LTE 014 014 014 014 UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE 014 014 014 UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTE UTE UTE UTE UTE EXT UTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE UTIL 1 UTIL 2 CAL 2

2 2

2 2

122 122 120 122 120 122 120 122 120 122 120 104 103 103 103 104 132 132 133 133 14 14 14 2

2 2

2 2

2 2

122 120 122 122 120 122 120 122 120 120 122 104 104 104 103 103 103 104 132 132 132 14 13 13 13 2

2 2

2 2

2 2

2 2

122 120 122 120 122 120 LEG PROBE INLET 51OUL INLET 51OUL INLET 51OUL INLET 51OUL INLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL INLET 51OUL INLET 51OUL INLET 51OUL INLET 51OUL INLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL INLET 51OUL INLET 51OUL INLET 51OUL INLET 51OUL INLET 51OUL INLET 51OUL INLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL INLET 51OUL INLET 51OUL INLET 51OUL INLET 51OUL INLET 51OUL INLET 51OUL INLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL INLET 51OUL INLET 51OUL INLET 51OUL INLET 51OUL INLET 51OUL INLET 51OUL INLET 51OUL INLET 51OUL INLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:14:57 Component: S/G A Page 28 of 56 ATTACHMENT #1 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW 7=4 74 74 74 74 74 74 74 75 75 75 75 75 75 75 75 75 75 75 75 75 75 75 75 75 75 75 75 75 75 75 75 75 75 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 77 77 77 77 77 77 77 77 TUBE VOLTS 89 30.11 90 39.18 91 23.07 92 8.80 112 0.36 117 17.75 121 0.33 125 6.34 0.48 4

22.20 7

0.30 46 21.96 9.67 21.50 51 0.49 53 16.79 61 6.08 63 7.74 64 6.09 68 11.33 69 19.60 70 9.61 71 9.27 84 7.52 85 24.66 86 39.00 88 61.65 89 34.83 90 34.78 91 30.78 92 19.75 101 0.38 112 0.27 117 15.59 119 16.41 0.91 123 0.91 126 0.57 0.86 64 17.09 6.26 65 7.22 67 6.37 68 25.63 70 21.11 71 11.35 72 8.18 84 10.29 85 37.50 86 44.75 87 69.66 0.45 88 0.33 67.48 89 29.91 90 48.74 92 13.78 116 14.04 7.80 117 18.24 7.30 123 0.63 1

30.22

9. 62 2

0.51 24.95 7

0.65 0.35 9

10.77 12.40 46 8.71 58 13.24 60 0.52 61 6.75 0.29 DEG 175 181 177 182 52 180 119 174 102 180 97 180 175 184 107 8

185 182 185 177 177 176 174 181 182 182 179 181 178 180 177 107 88 180 180 94 88 106 119 179 184 182 179 178 176 173 169 177 183 180 182 50 99 182 177 179 176 178 182 179 182 112 176 186 91 181 93 103 179 175 183 182 64 186 86 CH-N P 1 21 21 P 1 3

3 3

3 2 1 3

3 3

3 P 1 3

P 1 P 1 P 1 P1I 2 1 P 1 P 1 P 1 P 1 P 1 P1 P1 P 1 2 1 P 1 2 1 3

3 3

3 2 1 P 1 P1 3

2 1 2 1 21I 21I P1I 2 1 P 1 P 1 2 1 21I 2 1 P 1 3

3 2 1 21I 2 1 2 1 3

3 3

3 2 1 3

P1 3

3 3

3 3

3 P1 3

2 1 2 1 2 1 IND DNT DNT DNT DNT NQI DNT NQI DNT NQI DNT NQI DNT DNT DNT NQI BLG DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT TWD NQI DNT DNT TWD NQI NQI NQI DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT NQI NQI DNT DNT DNT DNT DNT DNT DNT DNT NQI DNT DNT NQI DNT NQI NQI DNT DNT DNT DNT NQI DNT NQI

%TW LOCATION LTS A

LTS A

LTS A

LTS A

011 A

LTE A

001 A

LTE A

010 A

LTE A

008 A

LTS A

LTS A

LTS 012 LTE A

UTS A

UTS A

UTS A

LTS A

LTS A

LTS A

LTS A

LTS 4

LTS

+

LTS 4

LTS A

LTS

+

LTS 4

LTS A

LTS 4

19 012 A

010 4

LTE 4

LTE A

24 014 A

009 013 A

015 A

LTS 4

UTS 4

UTS 4

LTS LTS 4

LTS LTS 4

LTS 4

LTS 4

LTS 4

LTS 4

LTS 4

LTS 4

002 4

LTS 4

LTS 4

LTS 4

LTS LTE 4

UTS 4

LTE

+

UTS

+

010

+

LTS

+

LTS LTS

+

LTE

+

LTS A

LTS A

LTS

+

LTS

+

LTS

+

LTE 4

004 UTS

+

LTS 0.16 nO.11

+0O. 131

+0.13 0.00

-29.67

-10.88

-25.78

-10.92

-0.24

-11.05

-19.03

-8.47

-3.61

-0.11

-1.06

-5.47

-0.09

-0.07

-0.09

-0.05

-0.05

-0.05

-0.02

-0.00

-0.29

-0.31

-0.02

-0.04

-0.04

-0.13

-0.11

-3.13

-2.21

-10.68

-10.71

-1.00

-0.76

-0.96

-22.37

-0.54

-0.07

-0.04

-0.02

+0.04

-0.07

-0.09

+0.16

-0.51

+0.24

+0.20

+0.22

  • 39.76

+4.69

+0.25

-0.07

-0.

11

-0.02

-10.68

-12.64

-10.85

-12.84

-0.55

-0.77

-0.07

-26.21

-11.11

-26.44

-26.06

-2.56

-2.16

-0.02

-2

. 15

-0.72

-0.07

-0.32 EXT EXT UTE LTE UTE LTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 014 LTE 014 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 014 LTE 014 LTE 014 LTE 014 LTE 014 LTE 014 LTE 014 LTE 014 LTE UTE LTE LTE UTE LTE UTE LTE UTE LTE UTE UTIL 1 UTIL 2 CAL 122 120 104 103 104 103 104 104 104 150 11 11 11 11 13 13 2

2 2

2 2

2 2

126 125 126 125 126 125 126 104 103 103 103 103 103 103 104 104 2

2 2

2 2

2 2

2 125 126 125 126 126 103 103 103 104 103 104 104 103 103 104 133 133 132 132 133 133 132 132 1350 3

3 3

3 LEG OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET PROBE 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 5lOUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:14:58 Component: S/G A Page 29 of 56 ATTACHMENT #1 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW TUBE VOLTS 77 62 6.02 77 68 6.19 77 70 26.38 77 71 34.83 77 72 9.23 0.50 0.45 77 84 6.35 77 85 17.62 77 86 48.33 77 87 57.40 77 88 67.81 77 89 39.48 77 90 36.39 77 91 53.70 77 92 22.61 77 93 7.65 77 112 0.41 77 115 1.08 77 119 1.17 77 125 0.79 78 2

22.64 78 11 0.41 78 12 8.05 78 15 0.42 78 34 0.55 78 43 6.77 78 46 6.09 78 50 6.30 78 51 6.40 78 52 6.28 78 53 6.05 78 58 6.23 78 60 6.01 78 61 6.69 78 65 6.47 10.11 78 69 12.66 78 71 25.18 78 72 9.99 78 73 7.88 78 85 7.96 78 86 25.55 78 87 47.77 78 88 57.89 78 90 36.16 78 91 0.39 45.89 78 92 33.32 78 93 13.97 78 101 1.41 78 102 6.08 78 105 0.30 78 116 0.74 78 117 0.38 78 120 1.13 78 121 0.74 78 125 6.06 0.34 79 4

7.23 0.47 0.75 0.72 0.42 79 6

9.89 0.82 1.53 2.08 79 8

6.38 79 12 15.09 79 16 23.73 79 44 0.64 79 45 0.39 79 49 0.70 79 62 0.17 DEG 187 179 180 181 176 107 89 176 181 180 181 177 180 178 180 174 182 81 127 94 113 178 93 189 105 89 180 181 179 181 180 179 184 185 185 174 183 181 182 174 171 172 179 180 181 178 92 178 179 171 100 175 97 103 52 59 106 173 117 179 109 134 107 93 178 117 110 105 174 181 182 81 97 87 69 CNN P 1 P 1 P 1 P 1 P 1 3

3 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 3

3 P 1 P 1 3

3 3

3 3

P 1 P 1 P 1 P 1 P 1 P1I P 1 P 1 P 1 P 1 3

P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 3

P 1 P 1 P 1 P 1 3

3 3

P 1 P 1 P 1 P 1 P 1 3

P 1 P1I P 1 P1 3

P1 P 1 3

P 1 P 1 3

3 P 1 1

IND DNT DNT DNT DNT DNT NQI NQI DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT NQI NQI NQI NQI DNT NQI DNT NQI NQI DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT NQI DNT DNT DNT TWD DNT NQI NQI NQI NQI NQI DNT NQI DNT NQI NQI NQI NQI DNT NQI NQI NQI DNT DNT DNT NQI NQI NQI NQI

%TW LOCATION UTS

+0.02 LTS

+0.02 LTS

+0.11 LTS

+0.11 LTS

+0.11 012

+13.76 012

+21.32 LTS

-0.09 LTS

+0.38 LTS

+0.13 LTS

+0.13 LTS

+0.16 LTS

+0.07 LTS

+0.13 LTS

+0.09 LTS

+0.02 LTS

-0.07 012

+30.98 014

+1.18 014

+0.95 009

-0.04 LTE

+10.38 005

+32.67 012

+28.86 LTS

+23.31 014

+18.40 UTS

+0.00 UTS

+0.00 UTS

+0.00 UTS

+0.00 UTS

+0.00 UTS

+0.00 UTS

+0.09 UTS

+0.07 UTS

+0.09 LTS

+0.00 LTE

+3.69 LTS

+0.00 LTS

+0.09 LTS

+0.18 LTS

+0.05 LTS

-0.13 LTS

+0.31 LTS

+0.16 LTS

+0.16 LTS

+0.11 009

+24.92 LTS

+0.09 LTS

+0.09 LTS

-0.04 13 014

+1.23 LTE

+9.63 014

+3.94 014

+1.31 UTS

+0.72 014

+0.89 014

+0.71 009

-0.45 008

-0.49 LTE

+11.08 010

-0.56 012

-0.75 014

-0.66 014

+0.68 LTE

+10.97 012

-0.55 013

-0.82 014

-0.70 LTE

+11.11 014

+0.50 014

+0.00 015

+22.13 015

+17.02 009

-0.71 015

+21.27 TO+44.64 EXT LTE LTE LTE LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 014 014 014 014 014 UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 014 014 014 014 014 014 014 014 014 014 014 014 UTE UTE UTE LTE EXT UTE UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTE UTIL 1 UTIL 2

= = = =

CAL 3

3 3

3 3

3 3

4 3 42 43 42 43 42 43 42 43 42 43 42 42 42 133 133 132 133 132 150 150 150 150 150 150 3

3 3

3 3

3 3

3 3

43 42 43 42 42 43 43 42 43 43 42 43 42 43 42 43 43 43 132 132 132 132 132 132 132 1 32 132 133 133 150 150 150 150 3

  1. LEG INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET PROBE 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:14:58 Component: S/G A Page 30 of 56 ATTACHMENT #1 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW TUBE VOLTS 79 64 0.58 0.64 0.44 79 72 7.42 79 73 11.62 79 74 13.39 79 75 8.87 79 76 6.86 79 82 0.42 79 88 7.75 9.67 7.17 79 89 12.07 13.72 79 90 36.21 79 91 44.79 79 92 56.33 79 93 18.80 79 94 41.35 79 95 55.18 0.21 79 96 23.66 79 97 6.70 79 104 7.68 79 114 0.62 79 117 0.74 79 118 0.42 79 123 0.32 0.39 79 127 0.94 80 1

0.61 0.52 80 2

0.49 80 5

2.82 0.45 0.39 80 8

0.45 80 9

0.78 0.34 0.49 0.30 80 10 0.60 80 12 0.54 0.51 80 13 0.56 1.48 80 16 0.38 80 18 0.56 80 19 1.17 80 21 1.83 80 22 6.06 80 25 2.27 80 26 2.48 80 27 0.85 80 28 1.82 80 29 0.81 0.54 80 32 1.97 80 33 0.33 80 34 0.70 80 36 1.76 80 37 0.39 0.43 80 39 1.33 80 40 0.62 80 41 6.23 80 42 0.68 80 43 6.03 80 44 1.04 80 48 0.43 80 49 0.45 80 50 0.37 80 62 0.42 80 74 9.60 80 75 11.66 DEG 106 103 90 179 180 179 175 169 106 182 176 187 175 166 181 179 181 173 181 179 90 179 177 184 44 78 66 97 96 108 84 103 75 96 78 93 127 103 82 110 81 108 113 51 89 91 66 97 98 103 86 105 117 110 123 121 121 106 105 104 112 92 101 109 112 181 39 180 85 94 94 86 86 181 178 CHN 3

3 3

P 1 P 1 P 1 P1 P1 3

3 3

P 1 3

P 1 P 1 P 1 P 1 P 1 P1 3

P 1 P1 3

3 3

P 1 3

3 P1 3

3 3

P 1 P 1 P 1 P1 2 1 P1 3

3 P 1 P 1 P 1 P 1 P 1 P 1 P 1 3

3 6

3 3

3 3

3 P 1 3

3 3

3 P 1 P 1 3

3 P 1 P1 P 1 3

P 1 P1 P 1 P 1 IND %TW LOCATION NQI 013

+33.26 NQI 014

+33.17 NQI 014

+32.76 DNT LTS

-0.02 DNT LTS

+0.05 DNT LTS

+0.14 DNT LTS

+0.07 DNT LTS

+0.16 TWD 20 009

+36.37 DNT 006

+17.50 DNT LTS

+0.96 DNT LTS

-0.11 DNT LTS

+0.92 DNT LTS

+0.13 DNT LTS

+0.04 DNT LTS

+0.18 DNT LTS

+0.13 DNT LTS

+0.07 DNT LTS

+0.09 DNT LTS

+0.07 NQI 010

+11.07 DNT LTS

+0.02 DNT LTS

+0.02 DNT 002

+34.84 NQI LTS

+32.50 NQI 006

+27.53 NQI 015

+0.38 NQI 014

+28.08 NQI 014

+22.12 NQI 014

+0.40 NQI 013

+17.50 NQI 007

+5.37 NQI 011

+19.87 TO+30.81 NQI 012

-0.79 NQI 013

+0.33 NQI 014

+0.65 NQI 004

-0.77 NQI 014

-0.80 NQI 014

-0.41 NQI 010

+23.29 NQI 001

+3.34 NQI 014

-0.61 NQI 014

-0.62 NQI 014

+0.48 NQI 012

+0.40 NQI 014

-0.44 NQI 014

+0.68 NQI 014

+0.48 NQI 015

+20.83 NQI 015

+20.00 ADI 015

+20.30 NQI 015

+18.01 NQI 015

+17.30 NQI 015

+15.97 TO+19.91 NQI 015

+15.85 TO+18.75 NQI 015

+16.42 NQI 015

+0.64 NQI 015

+16.00 NQI 011

+9.66 TO+23.84 NQI 015

+15.32 NQI 015

+13.69 NQI 014

-0.27 NQI 014

-0.57 NQI 015

+14.39 NQI 015

+15.32 DNT UTS

-0.02 NQI 014

-0.64 DNT UTS

+0.00 NQI 010

+10.09 NQI 009

-0.80 NQI 009

-0.73 NQI 009

-0.77 NQI 015

+44.53 DNT LTS

+0.07 DNT LTS

+0.11 EXT LTE LTE LTE LTE LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 014 014 014 014 014 014 014 014 014 014 014 014 014 014 014 014 014 014 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE LTE LTE EXT UTE UTE UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTE UTE UTE UTIL 1 UTIL 2

==

CAL # LEG 3

TNLET 3

INLET 3

INLET 3

INLET 3

INLET 3

INLET 3

INLET 3

INLET 42 OUTLET 42 OUTLET 42 OUTLET 42 OUTLET 43 OUTLET 43 OUTLET 42 OUTLET 43 OUTLET 42 OUTLET 43 OUTLET 42 OUTLET 43 OUTLET 43 OUTLET 42 OUTLET 43 OUTLET 38 OUTLET 38 OUTLET 37 OUTLET 38 OUTLET 37 OUTLET 37 OUTLET 38 OUTLET 140 OUTLET 140 OUTLET 139 OUTLET 140 OUTLET 140 OUTLET 140 OUTLET 139 OUTLET 140 OUTLET 140 OUTLET 140 OUTLET 140 OUTLET 139 OUTLET 139 OUTLET 139 OUTLET 140 OUTLET 140 OUTLET 132 OUTLET 132 OUTLET 145 OUTLET 144 OUTLET 14S OUTLET 144 OUTLET 145 OUTLET 144 OUTLET 145 OUTLET 144 OUTLET 144 OUTLET 144 OUTLET 145 OUTLET 144 OUTLET 144 OUTLET 145 OUTLET 145 OUTLET 145 OUTLET 144 OUTLET 145 OUTLET 144 OUTLET 145 OUTLET 144 OUTLET 145 OUTLET 144 OUTLET 145 OUTLET 3

INLET 3

INLET 3

INLET PROBE 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 ATTACHMENT #1 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl 12/05/01 14:14:58 Component: S/G A Page 31 of 56 ROW TUBE VOLTS 80 83 0.48 80 85 0.46 80 89 6.94 80 90 17.50 80 91 25.50 80 92 36.59 80 93 63.10 80 94 37.40 80 96 57.19 80 97 43.43 80 98 11.97 0.29 80 130 0.45 81 4

0.72 2.73 81 5

0.49 81 6

0.84 0.83 81 7

0.89 0.42 81 9

1.33 0.43 81 10 1.41 0.28 81 11 1.73 81 13 0.72 0.81 81 14 0.53 81 16 0.50

0. 62 81 27 0.46 81 29 0.51 81 30 0.60 81 34 6.31 81 35 6.22 81 37 0.57 0.39 81 38 0.42 81 39 0.41 81 40 1.39 81 42 0.63 81 45 0.94 81 46 0.65 0.28 81 47 0.73 0.35 81 48 0.56 0.55 81 54 0.53 81 55 0.49 0.29 0.61 0.30 81 56 0.70 0.70 0.76 1.55 0.61 81 57 0.64 81 59 0.79 81 63 0.58 81 73 11.15 81 74 6.65 81 88 6.31 81 89 6.92 81 90 11.99 81 92 51.86 81 93 52.90 0.52 81 94 25.07 81 96 51.94 81 98 7.31 81 103 0.33 0.51 81 110 0.30 DEG CHN IND 87 P 1 NQI 81 P 1 NQI 176 3 DNT 178 3 DNT 181 P 1 DNT 181 P 1 DNT 179 P 1 DNT 180 P 1 DNT 180 P 1 DNT 180 P 1 DNT 174 P 1 DNT 120 3 NQI 109 P 1 NQI 112 P 1 NQI 105 P 1 NQI 115 3 NQI 104 P 1 NQI 51 P 1 NQI 95 P 1 NQI 97 P 1 NQI 103 P 1 NQI 126 P 1 NQI 121 P 1 NQI 96 3

NQI 114 P 1 NQI 107 3 NQI 116 P 1 NQI 98 P 1 NQI 93 3

NQI 88 P 1 DWI 78 P 1 NQI 102 3 NQI 97 P 1 NQI 180 P 1 DNT 187 P 1 DNT 100 P 1 NQI 95 P 1 NQI 115 P 1 NQI 88 3

NQI 99 P 1 NQI 85 P 1 NQI 106 P 1 NQI 97 P 1 NQI 56 P 1 NQI 100 P 1 NQI 55 P 1 NQI 100 P 1 NQI 89 P 1 NQI 108 P 1 NQI 110 P 1 NQI 73 P 1 NQI 87 P 1 NQI 97 P 1 NQI 63 P 1 NQI 90 P 1 NQI 90 P 1 NQI 91 P 1 NQI 103 P 1 NQI 58 P 1 NQI 84 P 1 NQI 97 3

NQI 182 P 1 DNT 178 P 1 DNT 181 3 DNT 174 3 DNT 180 P 1 DNT 180 P 1 DNT 179 P 1 DNT 106 P 1 NQI 180 P 1 DNT 180 P 1 DNT 170 P 1 DNT 87 3

NQI 99 3

NQI 83 3

NQI

%TW LOCATION EXT 004

-0.83 UTE 010

+1.06 UTE LTS

+0.86 UTE LTS

+0.88 UTE LTS

+0.22 UTE LTS

+0.18 UTE LTS

+0.00 UTE LTS

+0.16 UTE LTS

+0.11 UTE LTS

+0.00 UTE LTS

-0.02 UTE 015

+7.29 UTE 010

+0.49 UTE 012

-0.64 014 013

-0.71 014 010

+33.82 014 012

-0.67 014 013

+0.37 014 011

+1.08 014 011

+1.30 014 013

-0.88 014 014

-0.83 014 013

-0.80 014 006

+1.11 014 013

-0.78 014 015

+23.62 UTE 013

-0.77 UTE 013

-0.80 UTE 011

+12.64 UTE UTS

+0.09 UTE 007

-0.82 UTE 015

+19.01 UTE 015

+0.60 UTE UTS

+0.00 UTE UTS

+0.00 UTE 014

+0.33 UTE 014

+0.07 UTE 010

+0.53 UTE 010

+9.12 UTE 010

+0.47 UTE 009

-0.71 UTE 010

+0.51 UTE 009

+0.40 UTE 009

-0.75 UTE 009

-0.75 UTE 008

+0.51 UTE 008

+0.60 UTE 009

-0.73 UTE 008

-0.58 UTE 009

-0.75 UTE 008

+0.53 UTE 008

-0.64 UTE 007

-0.73 UTE 005

+0.60 UTE 007

+0.44 UTE 008

-0.71 UTE 007

-0.71 UTE 009

-0.73 UTE 005

+0.58 UTE 005

+0.68 LTE 015

+19.49 TO+44.83 LTE LTS

+0.14 LTE LTS

+0.05 LTE LTS

+0.81 UTE LTS

+0.92 UTE LTS

+0.00 UTE LTS

+0.00 UTE LTS

+0.11 UTE 014

+1.09 UTE LTS

+0.00 UTE LTS

+0.00 UTE LTS

-0.02 UTE 015

+27.68 UTE 015

+27.37 UTE 010

+12.13 UTE EXT LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTIL 1 UTIL 2

= = = =

CAL 37 37 37 38B 37 38 37 38 37 38 37 37 42 139 139 140 139 139 140 140 140 140 139 139 139 145 145 144 144 144 14S 145 144 144 145 14S 145 144 145 144 144 144 145 145 144 144 145 145 145 144 144 144 144 145 145 145 145 145 144 3

38 37 38 38 37 38 37 37 37 37 37 374 374 374 LEG OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET PROBE 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 5lOUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 ATTACHMENT #1 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl 12/05/01 14:14:58 Component: S/G A Page 32 of 56 ROW TUBE VOLTS 81 120 1.86 81 130 0.40 0.55 81 131 0.39 0.37 82 1

0.61 82 4

0.28 82 6

0.25 1.60 82 9

1.31 0.54 82 26 6.51 82 32 0.61 82 33 0.34 82 34 6.54 82 35 6.66 82 38 1.61 82 40 0.50 82 41 0.55 0.30 0.47 0.59 82 42 0.86 82 43 0.95 0.73

0. 65 82 44 0.37 1.05 0.78 82 45 0.49 82 46 0.59 82 72 12.74 82 73 7.05 82 83 0.29 0.26 82 89 8.32 82 90 25.69 82 91 47.95 82 92 67.42 0.28 82 93 49.54 82 94 24.86 82 95 57.80 82 96 21.58 82 97 8.95 82 109 0.27 82 113 0.21 82 123 0.65 82 125 0.61 83 6

0.98 83 8

0.46 1.04 1.77 0.44 83 15 0.45 83 18 0.29 83 21 0.43 83 23 6.33 83 26 0.68 83 27 0.56 83 28 1.01 83 30 6.05 83 31 0.62 83 32 0.43 83 34 0.63 83 37 0.34 83 43 0.48 0.79 83 72 6.06 83 73 17.83 83 74 12.49 83 75 6.98 83 91 15.02 83 92 37.89 83 93 51.81 DEG 93 114 53 83 94 76 91 99 123 119 81 183 107 76 186 180 86 79 24 77 80 102 104 82 53 112 97 102 108 100 113 179 173 101 89 182 180 180 181 76 180 181 180 176 166 125 99 111 85 108 101 100 97 95 109 88 108 183 82 73 91 182 108 110 100 91 80 103 183 181 176 173 179 180 181 CHN P 1 3

P 1 3

3 P 1 3

P 1 3

P 1 P 1 P1 P 1 P 1 P I P 1 6

P 1 P 1 3

P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 3

3 P 1 P 1 P 1 P 1 3

P 1 P 1 P 1 P 1 P 1 3

3 3

P 1 P 1 P 1 3

P 1 3

P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 Pa1 P 1 P 1 P 1 P 1 P 1 IND NQT NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI DNT NQI NQI DNT DNT ADI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI DNT DNT NQI NQI DNT DNT DNT DNT NQI DNT DNT DNT DNT DNT NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI DNT NQI NQI NQI DNT NQI NQI NQI NQI NQI NQI DNT DNT DNT DNT DNT DNT DNT

%TW LOCATION 014 4

013 013 4

015 015 4

011 011 010 011 011 013 UTS A

010 4

010 A

UTS

+

UTS

+

014 A

010 A

010

+

014 A

008

+

008 009 010

+

009 007 008

+

008 010 4

008 4

009 LTS LTS 4

011 4

LTS 4

LTS LTS 4

LTS 4

LTS

+

007 4

LTS 4

LTS 4

LTS

+

LTS

+

LTS 008

+

015

+

014

+

014

+

010

+

011

+

010

+

010

+

010 012

+

009

+

015

+

UTS

+

010

+

010

+

010

+

UTS

+

009

+

010 010

+

010

+

009 008 LTS

+

LTS

+

LTS

+

LTS

+

LTS

+

LTS

+

LTS

+

+0.65 41.02 FO.69

+29.50

+13.87

+0.53

+1.48

+0.00 F1.19

+0.73

+0.61

+0. 00

+0.58

+0.40

-0.00

-0.00

-18.17

-0.38

-0.47

-25.42

-0.66

-0.71

-0.73

-0.51

-0.80

-0.80

-0.53

-0.71

-0.56

-0.64

-0.77

-0.35

-0.16

-7.

14

-15.06

-0.07

+0.00

+0.18

+0.00

+14.94

+0.13

+0.00 0.04

  • 0.00 0.02

+32.07

  • 33.26 21.69 TO+33.32

+0.74

+33.93

  • 4.98 0.29 0.02 0.51 34.76

+0.58

  • 29.49
  • 0.

00

+0.31 0.45

+0.45 0.00

0. 60

-0.76

+0.56

+0.42

-0.75 0.69 0.07

+0.14 0.09

0. 11 0.00 0.20 0.00 EXT UTE UTE UTE UTE UTE 014 014 014 014 014 014 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE LTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 014 014 014 014 014 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE UTE UTE UTE EXT LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTE UTE UTE UTE LTE LTE LTE UTIL 1 UTIL 2 CAL # LEG PROBE 37 OUTLET 51OUL 42 OUTLET 51OUL 42 OUTLET 51OUL 43 OUTLET 51OUL 43 OUTLET 51OUL 143 OUTLET SlOUL 139 OUTLET 51OUL 139 OUTLET 51OUL 139 OUTLET 51OUL 139 OUTLET 51OUL 139 OUTLET 51OUL 145 OUTLET 51OUL 145 OUTLET 51OUL 144 OUTLET 51OUL 145 OUTLET 51OUL 144 OUTLET 51OUL 145 OUTLET 51OUL 145 OUTLET 51OUL 144 OUTLET 51OUL 144 OUTLET 51OUL 144 OUTLET 51OUL 144 OUTLET 51OUL 145 OUTLET 51OUL 144 OUTLET 51OUL 144 OUTLET 51OUL 144 OUTLET 51OUL 145 OUTLET 51OUL 145 OUTLET 510UL 145 OUTLET 51OUL 144 OUTLET 51OUL 145 OUTLET 51OUL 3

INLET 51OUL 3

INLET 51OUL 37 OUTLET 51OUL 37 OUTLET 51OUL 37 OUTLET 51OUL 38 OUTLET 51OUL 37 OUTLET 51OUL 38 OUTLET 51OUL 38 OUTLET 51OUL 37 OUTLET 51OUL 38 OUTLET 51OUL 37 OUTLET 51OUL 38 OUTLET 51OUL 37 OUTLET 51OUL 37 OUTLET 51OUL 37 OUTLET 51OUL 37 OUTLET 51OUL 37 OUTLET 51OUL 143 OUTLET 51OUL 142 OUTLET 51OUL 142 OUTLET 51OUL 142 OUTLET 51OUL 142 OUTLET 51OUL 144 OUTLET 51OUL 144 OUTLET 51OUL 145 OUTLET 51OUL 145 OUTLET 51OUL 144 OUTLET 51OUL 145 OUTLET 51OUL 144 OUTLET 51OUL 144 OUTLET 51OUL 145 OUTLET 51OUL 144 OUTLET 51OUL 144 OUTLET 51OUL 145 OUTLET 51OUL 145 OUTLET 51OUL 145 OUTLET 51OUL 3

INLET 51OUL 3

INLET 51OUL 3

INLET 51OUL 3

INLET 51OUL 38 OUTLET 51OUL 37 OUTLET 51OUL 38 OUTLET 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:14:59 Component: S/G A Page 33 of 56 ATTACHMENT #1 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW 83 83 83 83 83 83 83 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 TUBE VOLTS 94 73.74 95 23.44 96 38.02 97 30.34 98 0.74 0.29 16.23 104 0.40 132 0.66 1

0.74 2

0.41

0. 60 3

0.96 6

1.01 9

0.83 16 6.77 17 0.30 0.44 0.34

6. 97 19 0.43 26 0.61 28 0.37 29 0.67 30 0.53 32 0.43 55 1.20 63 7.39 64 9.79 65 8.77 66 9.43 67 7.90 69 7.03 71 10.98 72 35.99 73 31.53 74 17.00 91 26.86 92 42.78 93 65.96 96 48.36 97 9.83 98 7.07 103 0.25 118 1.85 0.59 127 19.73 9

0.53 13 0.24 14 0.42 16 6.61 19 6.55 22 0.47 25 0.66 26 0.84 0.52 27 0.49 29 0.58 34 0.41 36 0.59 42 1.59 1.37 0.76 44 0.75 51 0.34 56 0.27 61 20.60 0.32 62 23.53 0.29 63 22.52 64 35.43 65 26.30 66 20.94 67 15.13 DEG 180 177 178 179 98 102 176 108 98 148 100 107 54 111 86 178 104 64 93 183 58 105 92 116 49 92 63 182 183 181 181 180 181 182 182 182 180 180 181 180 178 175 180 92 91 96 178 110 89 106 183 179 94 108 115 121 130 119 108 101 44 88 81 127 107 85 177 95 176 57 179 185 177 177 176 CHN P 1 P 1 P 1 P 1 3

3 P 1 3

3 P1 P 1 P 1 P1 3

P 1 P1 3

3 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 3

P 1 P 1 3

P1 3

P 1 P 1 P 1 3

P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P1 P 1 3

P 1 P 1 3

P 1 3

P 1 P 1 P 1 P 1 P 1 IND DNT DNT DNT DNT NQI NQI DNT NQI NQI NQI NQI NQI NQI NQI NQI DNT TWD NQI NQI DNT NQI NQI NQI NQI NQI NQI NQI DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT NQI TWD TWD DNT NQI NQI NQI DNT DNT NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI DNT NQI DNT NQI DNT DNT DNT DNT DNT

%TW LOCATION LTS

+0.13 LTS

+0.00 LTS

+0.09 LTS

+0.00 008

+17.65 008

+18.61 LTS

+0.00 010

+5.29 015

+12.00 TO+28.00 011

-0.62 010

+0.11 010

-0.27 010

+0.58 010

+3.02 010

+0.51 UTS

+0.00 23 013

+22.37 012

+33.16 010

+0.27 UTS

+0.00 011

+0.60 010

+0.53 010

+0.40 004

-0.75 015

+0.66 010

+0.49 005

+0.64 LTS

+0.05 LTS

+0.02 LTS

+0.02 LTS

+0.05 LTS

+0.07 LTS

-0.36 LTS

+0.05 LTS

+0.07 LTS

+0.16 LTS

+0.16 LTS

+0.09 LTS

+0.13 LTS

+0.11 LTS

+0.13 LTS

-0.04 LTS

+0.00 015

+21.23 40 014

+0.68 29 014

+0.91 015

+40.83 009

-0.79 003

+10.42 010

-0.51 UTS

-0.02 UTS

+0.05 011

+5.73 010

+0.60 010

+0.56 010

-0.76 010

-0.74 010

-0.77 009

-0.73 009

-0.80 009

+0.56 009

-0.71 008

-0.73 008

-0.71 010

+9.35 015

+0.18 LTS

+0.05 015

+25.65 LTS

+0.07 LTS

+19.18 LTS

+0.07 LTS

+0.14 LTS

+0.11 LTS

+0.09 LTS

+0.05 EXT EXT UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE 014 LTE 014 LTE 014 LTE 014 LTE 014 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE UTIL 1 UTIL 2 CAL 37 38 37 38 37 37 37 37 43 143 142 142 143 143 145 144 145 145 145 145 145 144 144 145 144 144 148 3

3 3

3 3

3 3

3 3

3 34 34 37 37 38 37 37 318 318 37 147 147 148 148 147 148 148 147 1 47 148 148 148 147 31 1

14 14 14 14 1

1 1

  1. LEG OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL SlOUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:14:59 Component: S/G A Page 34 of 56 ATTACHMENT #1 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 87 87 87 87 87 87 87 87 TUBE 68 69 70 71 72 73 84 90 91 92 93 94 95 96 97 110 114 118 129 130 1

3 11 14 28 30 32 33 34 51 55 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 90 91 92 93 94 95 96 103 118 129 131 9

13 19 50 57 58 59 60 VOLTS 13.42

14. 97 21.83 56.20 78.59 25.80 0.34 25.75 0.35 41.09 55.38
65. 15 32.64 48.40 0.38
15. 61 11.69 0.22 0.33 0.75 6.96 0.54 0.70 10.09 0.30 7.25 0.96 0.52 0.27 0.37 0.78 0.75 0.50 0.43 0.91 6.18 16.04 33.57 42.16 40.19 31.32 58.58 46.24 29.46 16.92 0.57 11.29 15.51 23.60 31.19 38.74 26.61 0.27
9. 12 14.24 3.51 36.28 59.39 60.11 46.71 51.39 46.83 24.11 0.48 0.26 6.70 0.25 0.43 0.39 0.26 0.42 9.47 25.72
62. 68 70.16 DEG 176 177 175 182 183 180 107 183 71 181 182 180 174 179 85 159 179 94 90 96 184 43 89 175 101 178 104 101 103 70 108 99 98 102 118 181 178 182 183 181 184 183 185 180 184 76 176 184 185 182 182 182 108 160 182 22 179 182 181 176 181 180 176 90 95 179 112 111 79 102 101 173 181 184 183 CE p

p p

P P

P 3

P 3

P P

P P

P 3

P P

3 P

3 P

P P

3 3

P P

P P

P P

P P

3 P

P P

p p

P P

P P

P P

P P

P P

P P

P 3

P P

P P

P P

P P

P P

3 3

P 3

P P

3 P

P P

P P

IN IND

==

===:

1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT NQI 1 DNT NQI 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT NQI 1 DNT 1 DNT NQI 1 NQI NQI 1 DNT 1 NQI 1 NQI DNT NQI 1 DNT 1 NQI 1 NQI 1 NQI 1 NQI 1 NQI 1 NQI 1 NQI NQI 1 NQI 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 NQI 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT TWD 1 DNT 1 DNT 1 DWI 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT NQI NQI 1 DNT NQI 1 NQI 1 NQI NQI 1 NQI 1 DNT 1 DNT 1 DNT 1 DNT

%TW LOCATION LTS

+0.05 LTS

+0.09 LTS

+0.09 LTS

+0.14 LTS

+0.16 LTS

+0.16 010

+21.25 LTS

+0.16 012

+18.44 LTS

+0.16 LTS

+0.11 LTS

+0.07 LTS

+0.07 LTS

+0.09 007

+8.82 LTS

+0.05 LTS

+0.00 014

+1.03 014

+0.92 002

+32.63 008

-0.11 009

-0.06 014

+0.64 LTE

+10.31 012

+32.69 010

-0.36 010

-0.63 011

-0.71 009

-0.44 009

-0.97 009

-0.71 010

+0.63 009

-0.69 008

+35.85 005

-0.80 LTS

-0.81 LTS

-0.64 LTS

+0.05 LTS

+0.11 LTS

+0.11 LTS

+0.14 LTS

+0.18 LTS

+0.16 LTS

+0.11 LTS

+0.11 004

-0.68 LTS

+0.11 LTS

+0.18 LTS

+0.23 LTS

+0.16 LTS

+0.18 LTS

+0.18 L7 006

+33.99 LTS

+0.20 LTS

+0.23 LTS

-0.04 LTS

+0.16 LTS

+0.16 LTS

+0.11 LTS

+0.07 LTS

+0.02 LTS

+0.07 LTS

+0.05 015

+31.29 015

+10.53 008

-0.11 013

+1.42 010

-0.58 010

-0.36 LTS

+26.41 009

-0.82 LTS

+0.02 LTS

+0.07 LTS

+0.14 LTS

+0.16 EXT LTE LTE LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 014 014 014 014 UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE EXT UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTE UTE UTE UTE UTIL 1 UTIL 2

==

=

CAL #

12 1

1 1

1 123 33 34 34 33 34 33 34 34 33 34 33 33 34 33 34 143 143 143 143 148 147 147 147 147 148 147 148 148 1

1 1

1 1

1 1

1 11 1

1 1

1 1

1 1

1 1

33 33 34 33 34 33 123 34 33 34 33 34 34 147 147 147 148 1

1 1

1 LEG INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET PROBE 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 510UL 51OUL 510UL 51OUL 510UL 51OUL 510UL 510UL 51OUL 510UL 51OUL 510UL 51OUL 51OUL 51OUL 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:14:59 Component: S/G A Page 35 of 56 ATTACHMENT #1 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 88 89 89 89 89 89 89 89 89 89 89 89 89 89 TUBE VOLTS 61 45.61 0.27 62 37.93 64 45.04 65 33.05 0.46 66 14.14 67 12.89 68 9.90 69 13.68 71 17.64 72 25.80 8.70 73 9.25 89 9.55 90 27.67 91 35.08 92 71.57 93 53.48 94 47.28 95 27.89 96 9.22 122 0.53 129 8.07 130 2.75 2

1.91 3

0.91 0.77 57 15.88 58 35.04 59 43.92 60 66.76 61 79.15 62 85.05 63 67.31 64 48.47 26.09 0.15 65 30.31 20.20 66 10.66 10.60 67 7.26 68 7.74 70 8.44 72 9.76 73 10.03 80 0.28 90 16.06 91 44.26 92 50.28 93 56.88 94 42.02 95 36.60 96 0.18 8.42 122 0.42 125 0.42 2

1.18 6.90 14 0.52 0.32 16 0.67 17 0.75 37 0.48 55 16.50 56 32.35 57 39.99 58 33.68 59 44.63 0.33 0.25 60 65.03 61 80.15 62 55.17 DEG CHN IND 183 P 1 DNT 108 3 NQI 184 P 1 DNT 179 P 1 DNT 181 P 1 DNT 52 P 1 NQI 183 P 1 DNT 180 P 1 DNT 168 P 1 DNT 183 P 1 DNT 183 P 1 DNT 181 P 1 DNT 353 3 DNT 170 P 1 DNT 181 P 1 DNT 178 P 1 DNT 180 P 1 DNT 181 P 1 DNT 180 P 1 DNT 179 P 1 DNT 178 P 1 DNT 178 P 1 DNT 112 P 1 NQI 180 P 1 DNT 91 6

ADI 126 3 NQI 127 P 1 NQI 93 P 1 NQI 177 P 1 DNT 181 P 1 DNT 184 P 1 DNT 184 P 1 DNT 184 P 1 DNT 183 P 1 DNT 184 P 1 DNT 184 P 1 DNT 177 3 DNT 74 P 1 NQI 182 P 1 DNT 179 3 DNT 176 P 1 DNT 178 3 DNT 169 P 1 DNT 178 P 1 DNT 186 P 1 DNT 183 P 1 DNT 180 P 1 DNT 84 3

NQI 179 P 1 DNT 179 P 1 DNT 179 P 1 DNT 180 P 1 DNT 179 P 1 DNT 178 P 1 DNT 86 3

NQI 181 P 1 DNT 85 P 1 NQI 103 P 1 NQI 114 P 1 NQI 181 P 1 DNT 118 3 NQI 111 3 NQI 90 P 1 NQI 107 P 1 NQI 108 3 NQI 179 P 1 DNT 184 P 1 DNT 181 P 1 DNT 183 P 1 DNT 183 P 1 DNT 105 3 NQI 79 3

NQI 183 P 1 DNT 183 P 1 DNT 184 P 1 DNT

%TW LOCATION LTS

+0.18 015

+22.42 TO+35.40 LTS

+0.18 LTS

+0.27 LTS

+0.16 002

-0.70 LTS

+0.16 LTS

+0.14 LTS

+0.20 LTS

+0.18 LTS

+0.14 LTS

+0.16 LTS

+0.66 LTS

+0.14 LTS

+0.29 LTS

+0.09 LTS

+0.11 LTS

+0.11 LTS

+0.07 LTS

+0.11 LTS

+0.02 LTS

-0.07 002

+0.69 008

+0.25 012

+15.38 010

+5.21 012

-0.79 011

+0.64 LTS

+0.05 LTS

+0.09 LTS

+0.14 LTS

+0.16 LTS

+0.23 LTS

+0.23 LTS

+0.18 LTS

+0.14 LTS

+0.57 014

+0.21 LTS

+0.11 LTS

+0.50 LTS

+0.09 LTS

+0.48 LTS

+0.07 LTS

+0.09 LTS

+0.11 LTS

+0.20 LTS

+0.18 014

+8.87 LTS

+0.09 LTS

+0.11 LTS

+0.07 LTS

+0.05 LTS

+0.07 LTS

+0.00 015

+26.99 LTS

-0.11 015

+0.60 006

-0.58 011

+0.50 010

-0.16 014

+3.04 014

+2.71 010

+0.48 009

-0.75 014

+18.50 LTS

-0.04 LTS

+0.09 LTS

+0.07 LTS

+0.11 LTS

+0.16 015

+31.21 015

+30.09 LTS

+0.18 LTS

+0.18 LTS

+0.25 EXT EXT LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE 014 LTE 014 LTE 014 LTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE 014 LTE 014 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE UTIL 1 UTIL 2 CAL 1

1 1

1 1

34 33 34 33 34 33 34 33 34 33 34 142 142 142 1

1 1

1 1

1 1

1 1

1 34 34 33 34 33 34 33 34 33 34 14 142 142 1

1 1

1 1

1 346 1

1 1

1 14 13 14 13 34 342 342 1336 1346 1336 3 49 3 46 3 46 14 14 13 13 1

LEG INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 5lOUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:15:00 Component: S/G A Page 36 of 56 ATTACHMENT #1 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW 89 89 89 89 89 89 89 89 89 89 89 89 89 89 89 89 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 91 91 91 91 91 91 91 91 91 91 91 91 91 91 91 TUBE VOLTS 63 36.76 9.70 64 27.69 17.10 0.42 65 22.87 15.74 66 14.46 71 9.66 72 7.16 6.00 82 0.28 89 26.06 90 35.18 91 44.43 92 32.52 93 42.85 0.59 94 32.24 105 0.39 118 6.19 130 0.48 2

0.61 6

0.52 0.77 13 0.38 32 0.58 43 1.45 54 19.41 56 32.18 57 28.54 0.33 0.18 0.24 58 31.19 59 59.13 60 58.64 61 45.50 62 37.22 63 15.48 27.25 64 18.42 37.98 65 17.14 70 7.11 71 7.08 88 12.43 89 39.48 90 37.86 91 41.11 92 30.57 93 44.14 94 22.23 107 0.40 115 1.06 126 0.33 0.63 2

2.06 7

0.58 17 1.35 42 0.52 52 14.30 53 33.26 54 41.86 55 33.90 56 23.81 57 33.94 58 54.59 59 0.30 0.32 38.09 60 21.52 0.32 61 45.36 62 6.69 DEG CHN IND 182 P 1 DNT 174 3 DNT 185 P 1 DNT 180 1 DNT 78 P 1 NQI 184 P 1 DNT 179 3 DNT 181 P 1 DNT 179 3 DNT 164 P 1 DNT 177 3 DNT 90 3

NQI 178 P 1 DNT 181 P 1 DNT 180 P 1 DNT 180 P 1 DNT 180 P 1 DNT 101 3 TWD 180 P 1 DNT 87 3

NQI 186 3 DNT 84 P 1 NQI 134 P 1 NQI 70 P 1 NQI 75 P 1 NQI 105 3 NQI 66 3

NQI 96 P 1 NQI 176 P 1 DNT 183 P 1 DNT 184 P 1 DNT 102 3 NQI 74 3

NQI 94 3

NQI 180 P 1 DNT 182 P 1 DNT 183 P 1 DNT 184 P 1 DNT 177 P 1 DNT 180 P 1 DNT 177 3 DNT 180 P 1 DNT 176 3 DNT 179 3 DNT 178 3 DNT 184 3 DNT 176 P 1 DNT 177 P 1 DNT 179 P 1 DNT 178 P 1 DNT 179 P 1 DNT 178 P 1 DNT 179 P 1 DNT 105 P 1 NQI 91 P 1 NQI 83 P 1 NQI 100 P 1 NQI 104 P 1 NQI 75 P 1 NQI 94 P 1 NQI 92 P 1 NQI 174 P 1 DNT 181 P 1 DNT 185 P 1 DNT 183 P 1 DNT 182 P 1 DNT 179 P 1 DNT 181 P 1 DNT 67 3

NQI 82 3

NQI 182 P 1 DNT 181 P 1 DNT 69 3

NQI 179 3 DNT 177 P 1 DNT

%TW LOCATION LTS

+0.14 LTS

+0.57 LTS

+0.11 LTS

+0.57 002

-0.72 LTS

+0.14 LTS

+0.61 LTS

+0.23 LTS

+0.75 LTS

+0.14 LTS

+0.91 010

+15.33 LTS

+0.07 LTS

+0.13 LTS

+0.11 LTS

+0.09 LTS

+0.05 29 010

+22.58 LTS

+0.11 001

+5.23 LTS

+18.42 008

+0.56 012

-0.81 UTS

+0.11 009

-0.68 013

+28.89 006

+15.08 015

+0.78 LTS

+0.00 LTS

+0.23 LTS

+0.20 008

+24.46 008

+24.68 011

+14.93 LTS

+0.16 LTS

+0.18 LTS

+0.23 LTS

+0.25 LTS

+0.32 LTS

+0.11 LTS

+0.61 LTS

+0.11 LTS

+0.61 LTS

+0.59 LTS

+0.75 LTS

+0.77 LTS

+0.16 LTS

+0.11 LTS

+0.07 LTS

+0.07 LTS

+0.09 LTS

+0.11 LTS

+0.00 UTS

+5.04 014

+0.98 006

+0.40 LTS

-0.42 011

+0.48 010

+0.55 015

+0.57 015

+0.45 LTS

+0.00 LTS

+0.00 LTS

+0.20 LTS

+0.27 LTS

+0.23 LTS

+0.14 LTS

+0.16 011

+25.24 011

+28.84 LTS

-0.04 LTS

+0.16 012

+20.90 LTS

+0.54 LTS

-0.02 EXT EXT UTIL 1 UTIL 2 LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 014 UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 014 UTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE CAL 4 LEG PROBE 1

INLET S=OUL 1

INLET 51OUL 1

INLET 51OUL 1

INLET 51OUL 1

INLET 51OUL 1

INLET 51OUL 1

INLET 51OUL 1

INLET 51OUL 1

INLET 51OUL 1

INLET 51OUL 1

INLET 51OUL 34 OUTLET 51OUL 33 OUTLET 51OUL 34 OUTLET 51OUL 33 OUTLET 51OUL 34 OUTLET 51OUL 33 OUTLET 51OUL 33 OUTLET 51OUL 34 OUTLET 51OUL 33 OUTLET 51OUL 33 OUTLET 51OUL 34 OUTLET 51OUL 142 OUTLET 51OUL 136 OUTLET 51OUL 136 OUTLET 51OUL 138 OUTLET 51OUL 136 OUTLET 51OUL 138 OUTLET 51OUL 136 OUTLET 51OUL 1

INLET 51OUL 1

INLET 51OUL 1

INLET 51OUL 1

INLET 51OUL 1

INLET 51OUL 1

INLET 51OUL 1

INLET 51OUL 1

INLET 51OUL 1

INLET 51OUL 1

INLET 51OUL 1

INLET 51OUL 1

INLET 51OUL 1

INLET 51OUL 1

INLET 51OUL 1

INLET 51OUL 1

INLET 51OUL 1

INLET 51OUL 32 OUTLET 51OUL 28 OUTLET 51OUL 32 OUTLET 51OUL 28 OUTLET 51OUL 32 OUTLET 51OUL 28 OUTLET 51OUL 32 OUTLET 51OUL 28 OUTLET 51OUL 28 OUTLET 51OUL 28 OUTLET 51OUL 28 OUTLET 51OUL 142 OUTLET 51OUL 146 OUTLET 51OUL 136 OUTLET 51OUL 136 OUTLET 51OUL 136 OUTLET 51OUL 136 OUTLET 51OUL 1

INLET 51OUL 1

INLET 51OUL 1

INLET 51OUL 1

INLET 51OUL 1

INLET 51OUL 1

INLET 51OUL 1

INLET 51OUL 1

INLET 51OUL 1

INLET 51OUL 1

INLET 51OUL 1

INLET 51OUL 1

INLET 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:15:00 Component: S/G A Page 37 of 56 ATTACHMENT #1 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW TUBE VOLTS 37.02 91 63 17.45 91 65 0.29 91 70 0.22 91 80 0.33 0.25 91 81 9.94 91 82 0.40 91 84 0.39 91 86 31.15 91 88 31.68 91 89 37.56 91 91 14.42 91 99 0.21 91 108 28.88 91 118 0.69 91 119 1.02 91 120 0.29 91 125 1.14 1.72 0.66 92 3

0.51 92 52 6.65 92 53 9.39 92 54 23.74 92 55 27.49 92 56 26.67 0.33 92 57 23.24 92 58 24.92 0.21 0.39 92 59 26.56 11.66 92 60 35.19 92 61 27.24 0.36 92 62 11.19 17.45 92 63 13.39 92 64 11.88 92 65 13.88 92 81 0.21 92 83 0.28 92 87 12.80 92 88 38.42 92 89 0.36 55.81 0.61 0.44 0.55 0.24 92 90 33.25 92 91 35.52 92 92 29.96 92 93 17.86 92 94 10.91 92 96 0.32 0.28 0.52 0.56 0.29 0.39 0.29 92 109 0.54 92 112 0.29 92 115 0.33 92 117 0.23 93 3

0.53 93 11 0.58 93 12 0.64 93 35 0.28 93 49 10.06 93 50 13.23 93 51 14.49 DEG 179 176 88 90 96 95 182 98 94 176 176 177 177 87 180 121 102 76 98 111 100 117 195 173 177 180 183 104 182 180 77 68 179 176 182 182 103 184 180 183 176 182 96 87 181 176 84 180 106 95 76 69 176 178 176 180 180 112 100 106 102 105 93 86 85 72 104 90 108 149 96 96 180 190 181 CHN 3

3 3

3 3

3 3

3 3

P 1 P 1 P 1 31 3

3 3

P 1 9 1 3

3 P 1 P 1 P 1 P 1 P 1 P 1 P 1 3

P 1 P 1 P1 3

P91 3

P1 3

P1 3

P 1 3

3 3

3 P 1 9 1 3

P 1 3

3 3

3 P 1 P1 P1 P 1 31 3

3 3

3 3

3 3

3 3

3 3

P 1 3

3 3

P 1 P 1 9 1 IND DNT DNT NQI NQI NQI NQI DNT NQI TWD DNT DNT DNT DNT NQI DNT NQI NQI NQI NQI NQI NQI NQI DNT DNT DNT DNT DNT NQI DNT DNT NQI NQI DNT DNT DNT DNT NQI DNT DNT DNT DNT DNT NQI NQI DNT DNT NQI DNT NQI NQI NQI NQI DNT DNT DNT DNT DNT NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI DNT DNT DNT

%TW LOCATION LTS

+0.57 LTS

+0.61 014

+17.01 015

+21.31 011

+21.59 010

+27.49 LTE

+5.12 012

+1.72 38 002

+33.22 LTS

+0.05 LTS

+0.14 LTS

+0.11 LTS

-0.02 013

+20.68 LTE

+10.48 014

+1.15 015

-0.67 008

-0.79 014

+2.51 014

+2.28 009

+0.47 010

+0.51 LTS

+0.00 LTS

+0.00 LTS

+0.00 LTS

+0.11 LTS

+0.25 002

+29.69 LTS

+0.27 LTS

+0.07 010

-0.16 012

+7.89 LTS

+0.09 LTS

+0.48 LTS

+0.11 LTS

+0.11 006

+31.63 LTS

+0.11 LTS

+0.61 LTS

+0.57 LTS

+0.64 LTS

+0.64 015

+2.67 011

+12.74 LTS

+0.18 LTS

+0.09 010

+0.00 TO+28.22 LTS

+0.09 009

+2.90 009

+37.82 012

+3.58 011

+22.75 LTS

+0.05 LTS

+0.07 LTS

+0.07 LTS

+0.00 LTS

-0.09 009

+28.33 009

+27.79 009

+27.40 009

+23.05 009

+22.67 009

+22.04 009

+21.66 012

+31.33 008

+32.19 014

+30.88 011

+7.46 010

+0.53 001

+27.47 003

+8.46 011

+28.54 LTS

-0.02 LTS

+0.00 LTS

+0.00 EXT LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 014 UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 014 UTE UTE UTE UTE UTE UTE EXT UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTIL 1 UTIL 2 CAL #

1 32 32 28 32 28 28 28 28 28 28 28 28 32 28 28 28 28 142 137 136 146 149 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 32 32 32 28 32 32 32 32 32 32 28 32 28 32 28 28 28 28 28 28 28 28 32 28 32 32 142 149 130 134 149 137 136 LEG INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET PROBE 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL S5OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:15:00 Component: S/G A Page 38 of 5 9 ATTACHMENT #1 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW 93 93 93 93 93 93 93 93 93 93 93 93 93 93 93 93 93 93 93 93 93 93 93 94 94 94 94 94 94 94 94 94 94 94 94 94 94 94 94 94 94 94 94 94 94 94 94 94 94 94 94 TUBE VOLTS 52 20.80 53 27.37 54 20.72 55 13.26 21.11 56 15.29 13.98 57 29.87 8.17 58 22.89 10.74 59 14.99 10.81 60 9.63 61 12.66 62 7.12 63 7.89 64 6.63 84 39.26 85 33.86 87 31.93 88 0.36 35.07 89 13.01 90 6.96 103 0.27 113 0.68 0.30 122 0.65 123 0.82 1.91 1.13 2

0.51 1.18 26 1.18 50 10.30 51 14.04 52 12.80 53 11.73 54 15.02 55 17.18 56 18.20 57 10.83 18.54 0.31 58 19.81 6.64 59 32.84 10.41 0.44 60 12.70 16.52 61 16.12 7.59 62 6.40 10.01 63 9.41 83 0.22 86 23.23 87 41.05 90 0.48 0.37 0.43 24.81 7.37 91 21.91 92 12.11 93 6.58 95 13.59 11.94 122 0.45 124 0.59 0.30 127 0.40 129 0.23 DEG 180 181 185 172 176 176 177 182 178 182 178 185 178 181 179 187 179 178 180 178 176 103 178 180 179 78 94 97 104 101 108 82 127 92 90 181 181 181 181 179 180 182 170 177 91 176 179 182 175 112 182 176 181 181 181 175 183 110 179 181 108 92 95 176 182 178 181 180 180 180 99 100 78 78 90 CHN P 1 P 1 P 1 P 1 3

P 1 3

P 1 3

P 1 3

P 1 3

3 3

3 3

3 P 1 P 1 P 1 3

P 1 P 1 P 1 3

3 3

3 P 1 3

P 1 P 1 P I P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 3

3 P 1 3

P 1 3

3 P 1 3

P 1 3

P 1 3

3 3

P 1 31 3

3 3

P 1 3

P 1 P 1 P 1 3

3 3

3 3

3 3

IND

=NT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT NQI DNT DNT DNT NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI DNT DNT DNT DNT DNT DNT DNT DNT DNT NQI DNT DNT DNT DNT TWD DNT DNT DNT DNT DNT DNT DNT NQI DNT DNT NQI NQI NQI DNT DNT DNT DNT DNT DNT DNT NQI NQI NQI NQI NQI

%TW LOCATION LTS

+0.00 LTS

+0.11 LTS

+0.23 LTS

+0.05 LTS

+0.39 LTS

+0.05 LTS

+0.41 LTS

+0.11 LTS

+0.57 LTS

+0.14 LTS

+0.61 LTS

+0.09 LTS

+0.61 LTS

+0.57 LTS

+0.61 LTS

+0.66 LTS

+0.68 LTS

+0.77 LTS

+0.16 LTS

+0.09 LTS

+0.07 011

+18.85 TO+26.65 LTS

+0.02 LTS

-0.15 LTS

-0.04 009

+13.57 010

+6.86 003

+26.40 008

+1.52 011

-0.79 009

+1.06 009

+0.61 012

-0.77 011

+0.62 014

+0.74 LTS

-0.09 LTS

+0.02 LTS

+0.00 LTS

+0.02 LTS

+0.07 LTS

-0.02 LTS

+0.18 LTS

-0.02 LTS

+0.34 006

+10.42 LTS

+0.07 LTS

+0.48 LTS

+0.11 LTS

+0.57 7

008

+8.55 LTS

+0.14 LTS

+0.61 LTS

+0.18 LTS

+0.68 LTS

+0.20 LTS

+0.75 LTS

+0.73 014

+17.99 LTS

+0.00 LTS

+0.09 010

+19.37 009

+36.01 009

+37.77 LTS

+0.05 LTE

+10.15 LTS

+0.02 LTS

-0.22 LTS

+0.00 LTE

+13.09 LTE

+12.65 014

+1.23 008

+18.49 001

+10.32 009

+1.35 LTS

+16.11 EXT EXT UTE LTE UTE LTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE 014 LTE 014 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTIL 1 UTIL 2 CAL 136 149 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 28 32 28 32 32 28 32 28 28 28 32 28 28 28 142 142 121 121 121 121 121 121 117 149 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

32 28 32 28 28 28 28 28 32 28 32 28 28 32 32 32 28 32

  1. LEG OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET PROBE 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:15:01 Component: S/G A Page 39 of 56 ATTACHMENT #1 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW TUBE VOLTS 95 49 7.84 95 50 12.96 95 51 11.70 95 52 17.74 95 53 15.61 95 54 22.76 95 55 13.78 95 56 13.65 95 57 18.21 13.83 95 58 22.19 17.04 95 59 20.64 17.60 95 60 14.65 16.26 95 61 10.54 13.85 12.35 95 62 7.96 95 69 0.73 95 78 0.27 95 84 17.65 95 85 30.89 95 86 29.29 95 87 33.90 95 88 23.08 95 89 18.21 95 90 29.43 95 91 9.10 95 112 0.52 0.63 95 115 0.26 95 117 0.54 96 3

0.40 96 4

0.70 96 25 0.35 96 39 0.30 96 48 9.69 96 49 9.08 96 50 11.67 96 51 12.15 96 52 19.69 96 53 13.29 96 54 15.75 96 55 10.36 96 56 15.15 16.99 96 57 7.34 19.98 96 58 25.48

8. 68 96 59 20.44 9.49 96 60 12.72 16.13 96 63 0.55 96 64 6.68 96 82 13.33 96 83 34.46 96 85 0.28 40.56 96 86 23.18 96 87 0.53 16.92 96 88 22.44 96 89 0.82 21.68 96 90 9.50 96 92 0.31 96 95 0.44 0.29 0.31 0.33 96 106 0.31 DEG 180 178 181 177 180 179 179 178 176 176 177 173 182 173 179 182 180 180 179 179 50 106 175 181 178 180 175 177 175 183 89 104 96 63 64 104 111 88 175 181 178 180 179 179 180 175 177 182 178 174 178 181 174 180 182 179 92 184 180 181 80 179 178 100 178 174 111 177 176 98 103 103 94 90 89 CHN P1I P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 3

P 1 3

P1 3

3 P1 P1 3

3 3

3 3

P 1 P 1 P 1 P 1 P 1 P 1 P 1 P1 3

3 3

3 P 1 P 1 3

3 P1 P1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 31 3

P 1 P 1 3

P 1 P1 3

P1 P1 3

P1 1

3 3

3 3

3 3

IND %TW DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT NQI TWD 16 DNT DNT DNT DNT DNT DNT DNT DNT NQI NQI NQI NQI NQI NQI NQI NQI DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT NQI DNT DNT DNT NQI DNT DNT NQI DNT DNT NQI DNT DNT NQI NQI NQI NQI NQI NQI LOCATIOI LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS 014 LTS 014 015 LTS LTS LTS LTS LTS LTS LTS LTS 011 011 001 014 004 004 014 007 LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS 014 LTS LTS LTS 015 LTS LTS 011 LTS LTS 008 LTS LTS 011 012 012 012 009 013 S

-0.07

-0.13

+0.09

+0.00

+0.05

+0.11

+0.18

+0.16

+0.07

+0.48

+0.09

+0.59

+0.07

+0.63

+0.63

+0.07

+0.07

+0.68

+30.51

+0.79

+24.28

+23.04

+0.07

+0.11

+0.11

+0.07

+0.07

+0. 11

+0.05

-0.04

+32.15

+32.14

+30.13

+10.25

-0.79

-0.79

+4.45

+20.71

+0.00

-0.02

-0.13

+0. 09

+0.18

+0.16

+0.13

+0.27

+0.00

+0.45

+0.51

+0.00

+0.00

+0.56

+0.02

+0.62

+0.49

+0.09

+10.40

+0.89

+0.25

+0.13

+29.90

+0.07

+0.00

+5.25 TO+24.32

+0.05

+0.02

+12.03 TO+36.37

+0.00

+0. 00

+10.51

+11.88

+10.69

+10.29

+9.50

+23.31 EXT EXT UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTIL 1 UTIL 2 CAL 121 117 121 117 121 117 117 149 1

1 1

1 1

1 1

1 1

1 1

1 1

28 28 32 28 32 28 32 28 32 28 123 32 32 117 121 121 121 117 121 117 121 117 121 117 146 149 149 146 146 149 149 146 146 149 149 149 146 24 123 24 24 24 24 24 24 24 24 24 24 124 124 124 124 123

  • LEG OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET PROBE 51OUL 51OUL 51OUL 51OUL S5OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 5lOUL 51OUL 51OUL 51OUL 51OUL 51OUL 5lOUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:15:01 Component: S/G A Page 40 of 56 ATTACHMENT #1 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW TUE 96 112 97 2

97 14 97 31 97 32 97 33 97 38 97 47 97 48 97 49 97 50 97 51 97 52 97 53 97 54 97 55 97 56 97 57 IBE 5

97 97 97 97 97 97 97 97 97 97 97 97 97 97 97 97 97 97 97 98 98 98 98 98 98 98 98 98 98 98 98 98 98 98 98 98 98 98 98 58 59 61 64 65 76 77 78 79 80 81 82 83 84 85 86 87 88 126 3

4 34 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 VOLTS 0.41 0.70 0.72 17.30 0.43 0.23 0.40 0.43 6.65 6.87 9.46 20.80 19.05 16.10 16.11 13.89 7.21 12.19 14.93 9.80 9.57 23.81 23.98 7.12 20.41

8. 93 8.50 9.39 8.35 12.56 0.61 16.88 9.51 6.84 6.19 12.51 14.46 24.08 26.66 34.75 24.95 18.19 16.75 23.46 2.27 21.55 21.21 0.38 0.63 0.44 0.29 0.28 8.34 9.71 15.37 14.21
15. 65 10.67 16.39 9.61 10.49 10.11 14.06 6.86 24.95 8.98 31.33 8.81 10.94 31.32 11.82 17.64 8.04 6.87
6. 63 DEG 108 115 97 115 95 78 106 118 179 175 181 178 181 179 176 177 170 181 175 178 182 177 175 180 179 184 176 182 181 179 71 179 184 181 184 179 178 179 181 179 181 177 180 176 10 177 179 99 105 97 98 110 176 180 176 178 179 181 179 175 173 183 176 179 178 183 176 179 183 178 179 176 182 182 183 CHN 3

P 1 P 1 3

3 P 1 3

3 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 3

3 3

3 P 1 3

3 P

3 P

1 P I P 1 P 1 P 1 P 1 P 1 P 1 3

P 1 3

P1 P 1 3

3P1 P 1 P 1 P 1 P 1 P1 P 1 P 1 3 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P I P 1 P 1 IND NQI NQI NQI NQI NQI NQI NQI NQI NNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT NQI DNT DNT NQI NQI NQI NQI NQI DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT

%TW LOCATION EXT 005

+27.35 UTE 010

+0.55 UTE 006

+0.82 UTE 013

+18.83 UTE 014

+10.16 UTE 009

-0.11 UTE 013

+4.65 UTE LTS

+20.05 UTE LTS

+0.00 UTE LTS

+0.00 UTE LTS

+0.05 UTE LTS

+0.09 UTE LTS

+0.16 UTE LTS

+0.11 UTE LTS

+0.11 UTE LTS

+0.22 UTE LTS

+0.07 UTE LTS

+0.38 UTE LTS

+0.00 UTE LTS

+0.46 UTE LTS

+0.53 UTE LTS

+0.02 UTE LTS

+0.02 UTE LTS

+0.56 UTE LTS

-0.24 UTE LTS

+0.43 UTE LTS

+0.16 UTE LTS

+0.76 UTE LTS

+0.83 UTE LTS

+0.74 UTE LTS

+5.87 UTE LTS

+1.02 UTE LTS

+0.91 UTE LTS

+0.20 UTE LTS

+0.95 UTE LTS

+0.23 UTE LTS

+0.34 UTE LTS

+0.14 UTE LTS

+0.14 UTE LTS

-0.13 UTE LTS

+0.14 UTE LTS

+0.00 UTE LTS

+0.14 UTE LTS

-0.07 UTE 008

+20.23 UTE LTS

+0.11 UTE LTE

+17.21 UTE 014

+2.88 UTE 010

+0.59 UTE 009

+11.60 TO+16.85 UTE 010

+4.81 UTE 011

+15.21 UTE LTS

-0.09 UTE LTS

+0.00 UTE LTS

+0.07 UTE LTS

+0.02 UTE LTS

+0.13 UTE LTS

+0.14 UTE LTS

+0.13 UTE LTS

+0.22 UTE LTS

+0.07 UTE LTS

+0.47 UTE LTS

-0.05 UTE LTS

+0.45 UTE LTS

+0.09 UTE LTS

+0.60 UTE LTS

+0.04 UTE LTS

+0.62 UTE LTS

+0.58 UTE LTS

+0.07 UTE LTS

+0.67 UTE LTS

+0.11 UTE LTS

+0.15 UTE LTS

+0.60 UTE LTS

+0.59 UTE EXT LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTIL 1 UTIL 2 CAL #

29 117 117 117 121 117 121 117 121 117 121 117 121 117 146 146 149 149 146 146 149 149 146 146 149 149 146 146 42 42 25 25 24 25 25 24 25 24 25 24 25 24 25 24 24 25 25 24 121 121 117 117 117 121 117 121 117 121 117 146 149 149 146 146 149 149 146 146 149 149 151 151 150 151 150 LEG OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET PROBE 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:15:01 Component: S/G A Page 41 of 56 ATTACHMENT #1 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW 98 98 98 98 98 98 98 98 98 98 98 98 98 98 98 98 98 98 98 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 100 100 100 TUBE 65 66 76 77 78 79 80 81 82 83 84 85 86 87 88 91 102 107 122 3

11 14 44 47 48 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 75 76 77 78 79 80 81 82 83 84 85 86 87 97 124 126 7

47 48 VOLTS 16.67 10.43 13.54 11.24 12.30 20.25 22.01 28.90 28.74 42.70 28.84 26.15 12.05 18.00 31.38 16.80 0.54 0.28 0.16

0. 1 9 0.18
0. 60 0.53 0.73 0.49 1.01 0.30
7. 93 7.92 11.49
15. 64 0.22 15.31 0.58 10.09 10.94 11.73 0.47
13. 60 19.25 11.23 7.81 25.55 14.04 29.30 22.83 12.03 0.61 23.76 11.79 10.23 18.07 14.49 9.57 17.32 9.03 9.35 10.56
35. 63 40.34 36.40 41.70 34.66 30.26 26.25 12.24 23.39 47.18 17.57 0.48
0. 68 0.42 0.40 7.48 10.49 DEG 184 179 185 181 180 182 180 179 178 179 178 179 178 179 178 176 87 79 70 109 103 101 113 111 103 84 104 179 178 177 181 108 178 89 180 177 176 113 178 179 181 177 174 184 183 175 178 84 182 184 177 184 184 185 177 181 181 184 179 179 177 182 179 180 179 181 179 180 175 91 84 111 82 175 180 CHN P 1 P 1 P 1 3

P1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 3

3 3

3 3

3 P 1 3

3 P 1 3

P 1 P1 P 1 P 1 3

P 1 P 1 P1 P 1 P 1 3

P 1 P 1 P 1 P 1 P 1 P1 P 1 P1 3

P 1 P 1 P 1 P 1 P1 P 1 P 1 3

P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P1 3

3 3

3 P 1 P 1 IND DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT NQT NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI BNT DNT DNT DNT DNT NQI DNT BNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT BNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT NQI NQI NQI DNT DNT

%TW LOCATION EXT LTS

+0.60 UTE LTS

+0.70 UTE LTS

+0.86 UTE LTS

+0.93 UTE LTS

+0.25 UTE LTS

+0.22 UTE LTS

+0.23 UTE LTS

+0.23 UTE LTS

+0.27 UTE LTS

+0.18 UTE LTS

+0.23 UTE LTS

+0.11 UTE LTS

+0.07 UTE LTS

+0.14 UTE LTS

+0.13 UTE LTS

+0.07 UTE 013

+24.76 UTE 008

+28.74 UTE 012

+14.99 UTE 012

+19.57 UTE 010

+11.53 UTE 014

+1.21 UTE 010

+0.61 UTE 009

+13.17 UTE LTS

+40.47 UTE 014

+0.76 UTE 014

+17.81 UTE LTS

-0.04 UTE LTS

-0.13 UTE LTS

+0.07 UTE LTS

+0.09 UTE 014

+8.68 UTE LTS

+0.11 UTE 014

-0.20 UTE LTS

+0.07 UTE LTS

+0.11 UTE LTS

+0.22 UTE 010

+32.17 UTE LTS

+0.33 UTE LTS

+0.00 UTE LTS

+0.38 UTE LTS

+0.49 UTE LTS

+0.07 UTE LTS

+0.60 UTE LTS

+0.07 UTE LTS

+0.04 UTE LTS

+0.62 UTE 011

+19.01 UTE LTS

+0.04 UTE LTS

+0.59 UTE LTS

+0.55 UTE LTS

+0.57 UTE LTS

+0.56 UTE LTS

+0.58 UTE LTS

+0.79 UTE LTS

+0.20 UTE LTS

+0.00 UTE LTS

+0.79 UTE LTS

+0.29 UTE LTS

+0.00 UTE LTS

+0.23 UTE LTS

+0.13 UTE LTS

+0.09 UTE LTS

+0.00 UTE LTS

+0.16 UTE LTS

+0.00 UTE LTS

+0.32 UTE LTS

+0.09 UTE LTS

+0.20 UTE LTS

+33.15 UTE 008

+1.36 UTE LTS

+0.82 UTE 010

+4.52 UTE LTS

-0.08 UTE LTS

+0.00 UTE EXT LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTIL 1 UTIL 2 CAL 42 43 23 24 24 123 24 24 24 24 24 24 24 24 123 24 24 24 24 24 24 25 118 118 118 117 117 121 117 117 121 117 117 121 121 117 151 151 151 150 150 151 151 150 150 151 151 151 150 150 151 150 42 42 24 24 23 23 24 23 24 23 24 23 24 23 24 23 24 19 20 20 117 117 118 LEG OUTLE]

OUTLEI OUTLEI OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET PROBE 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL r

51OUL 51OUL r

51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL r

51OUL r

51OUL r

51OUL r

51OUL r

51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL S5OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:15:02 Component: S/G A Page 42 of 56 ATTACHMENT #1 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW TUBE VOLTS 100 49 0.36 13.25 100 50 0.32 0.42 11.68 100 51 10.40 16.20 100 52 14.33 100 53 12.89 100 54 13.65 100 55 15.35 100 56 23.05 100 57 18.65 100 58 8.04 13.69 100 59 18.50 10.72 100 60 17.94 100 61 13.06 100 62 11.91 14.12 100 63 11.30 17.22 100 64 6.22 9.64 100 65 0.53 8.49 100 72 0.49 100 73 6.25 9.53 0.31 100 74 7.72 19.88 0.23 100 75 23.37 100 76 41.02 100 77 49.84 100 78 64.65 100 79 40.38 100 80 45.29 100 81 22.92 100 82 22.05 100 83 22.52 100 84 45.58 100 85 37.72 100 86 14.32 100 87 6.44 100 121 0.32 101 6 0.38 101 16 0.45 101 33 0.36 101 37 0.35 101 48 8.29 101 49 14.64 101 50 17.10 101 51 15.54 101 52 12.26 101 53 13.83 101 54 12.41 101 55 0.25 21.90 101 56 10.71 11.94 101 57 14.12 101 58 24.29 14.96 101 59 13.07 25.94 101 60 23.53 12.84 101 61 6.57 18.73 101 62 17.84 12.59 101 63 23.27 DEG CHN IND 99 3

NQI 176 P 1 DNT 76 3

NQI 108 3 NQI 180 P 1 DNT 86 6

ADI 178 P 1 DNT 179 P 1 DNT 177 P 1 DNT 175 P 1 DNT 182 P 1 DNT 175 P 1 DNT 180 P 1 DNT 180 P 1 DNT 173 P 1 DNT 181 P 1 DNT 184 P 1 DNT 173 P 1 DNT 179 P 1 DNT 178 P 1 DNT 174 P 1 DNT 180 P 1 DNT 182 P 1 DNT 184 P 1 DNT 184 P 1 DNT 79 3

NQI 182 P 1 DNT 68 P 1 NQI 175 3 DNT 183 P 1 DNT 103 3 NQI 176 3 DNT 183 P 1 DNT 80 3

NQI 183 P 1 DNT 182 P 1 DNT 181 P 1 DNT 182 P 1 DNT 181 P 1 DNT 182 P 1 DNT 179 P 1 DNT 179 P 1 DNT 182 P 1 DNT 181 P 1 DNT 182 P 1 DNT 179 P 1 DNT 179 P 1 DNT 83 3

NQI 104 3 NQI 102 3 NQI 101 3 NQI 105 3 NQI 177 P 1 DNT 179 P 1 DNT 180 P 1 DNT 178 P 1 DNT 178 P 1 DNT 179 P 1 DNT 177 P 1 DNT 93 3

NQI 176 P 1 DNT 177 P 1 DNT 181 P 1 DNT 173 P 1 DNT 180 P 1 DNT 183 P 1 DNT 178 P 1 DNT 174 P 1 DNT 178 P 1 DNT 182 P 1 DNT 179 P 1 DNT 173 P 1 DNT 176 P 1 DNT 181 P 1 DNT 180 P 1 DNT

%TW LOCATION EXT 006

+29.48 UTE LTS

-0.17 UTE 011

+22.96 UTE 002

+33.54 UTE LTS

+0.00 UTE LTS

+21.82 TO+29.77 UTE LTS

+0.13 UTE LTS

+0.00 UTE LTS

+0.17 UTE LTS

+0.07 UTE LTS

+0.00 UTE LTS

+0.24 UTE LTS

+0.00 UTE LTS

+0.51 UTE LTS

+0.04 UTE LTS

+0.00 UTE LTS

+0.57 UTE LTS

+0.09 UTE LTS

+0.00 UTE LTS

+0.64 UTE LTS

+0.13 UTE LTS

+0.00 UTE LTS

+0.60 UTE LTS

+0.11 UTE LTS

+0.58 UTE 007

+32.16 UTE LTS

+0.54 UTE 004

-0.31 UTE LTS

+0.72 UTE LTS

+0.18 UTE 002

+31.42 UTE LTS

+0.74 UTE LTS

+0.22 UTE 013

+20.03 UTE LTS

+0.13 UTE LTS

+0.11 UTE LTS

+0.11 UTE LTS

+0.09 UTE LTS

+0.09 UTE LTS

+0.02 UTE LTS

+0.02 UTE LTS

+0.20 UTE LTS

+0.11 UTE LTS

+0.05 UTE LTS

+0.13 UTE LTS

-0.02 UTE LTS

-0.17 UTE 013

+12.29 UTE 008

+22.51 UTE 009

+20.35 UTE 012

+1.39 UTE LTS

+27.74 UTE LTS

+0.00 UTE LTS

+0.02 UTE LTS

+0.00 UTE LTS

+0.09 UTE LTS

+0.00 UTE LTS

+0.11 UTE LTS

+0.09 UTE 015

+5.96 UTE LTS

+0.18 UTE LTS

+0.00 UTE LTS

+0.38 UTE LTS

+0.04 UTE LTS

+0.00 UTE LTS

+0.46 UTE LTS

+0.56 UTE LTS

+0.07 UTE LTS

+0.00 UTE LTS

+0.55 UTE LTS

+0.60 UTE LTS

+0.09 UTE LTS

+0.07 UTE LTS

+0.60 UTE LTS

+0.09 UTE EXT LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTIL 1 UTIL 2 CAL 117 117 118 118 118 117 117 118 117 151 150 151 150 151 151 150 150 151 150 151 151 150 150 42 42 43 43 16 123 123 123 16 16 16 123 16 123 16 123 16 123 16 123 16 123 16 123 20 117 118 117 117 118 117 118 117 118 117 151 151 151 150 150 151 150 150 151 151 150 150 151 151 150 150 42 LEG OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET PROBE 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL SOUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL S5OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:15:02 Component: S/G A Page 43 of 56 ATTACHMENT #1 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW TUBE VOLTS 13.04 101 64 12.41 7.41 101 65 12.52 101 66 0.25 9.46 101 67 6.55 101 70 1.03 101 72 18.86 101 73 40.96 101 75 32.48 101 76 36.15 101 77 42.71 101 78 35.67 101 79 38.63 101 80 31.69 101 81 32.88 101 82 42.60 101 83 36.06 101 84 25.19 101 85 13.09 101 111 0.37 101 123 0.39 101 124 0.57 102 14 0.30 0.22 0.22 102 47 6.35 102 48 10.80 102 49 0.26 14.75 102 50 15.53 102 51 16.28 102 52 11.39 102 53 18.96 102 54 22.50 102 55 23.26 102 56 16.39 102 57 16.83 9.11 102 58 17.72 14.97 102 59 22.48 18.13 102 60 27.93 14.81 102 61 24.71 0.39 102 62 22.00 102 63 25.19 102 64 6.09 16.25 102 65 12.83 102 66 8.80 102 67 12.30 102 68 13.18 6.95 102 69 7.34 102 70 7.73 102 71 12.60 102 72 32.64 102 73 50.26 102 74 36.38 102 75 34.58 102 76 28.98 102 77 31.83 102 78 33.33 102 79 21.45 102 80 36.57 102 81 0.27 0.41 51.66 102 82 37.41 102 83 17.21 102 84 10.42 DEG 183 184 176 183 98 179 185 111 181 183 181 181 181 181 183 182 182 183 182 182 183 60 95 69 94 108 99 178 178 104 176 180 178 177 179 177 183 173 181 182 173 178 181 182 174 178 179 107 176 180 178 182 182 179 182 181 175 181 177 178 182 181 179 179 179 179 180 178 180 95 108 181 180 180 181 CHN IND %TW P 1 DNT P 1 DNT P 1 DNT P 1 DNT 3

NQI P 1 DNT P 1 DNT P 1 NQI P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 NQI P 1 NQI P 1 NQI 3

NQI 3

NQI 3

NQI P 1 DNT P 1 DNT 3

NQI P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT 3

NQI P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT 3

DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT 3

NQI 3

NQI P 1 DNT P 1 DNT P 1 DNT P 1 DNT LOCATION LTS

+0.58 LTS

+0.62 LTS

+0.09 LTS

+0.53 006

+26.01 LTS

+0.54 LTS

+0.56 LTS

-0.04 LTS

+0.11 LTS

+0.17 LTS

+0.11 LTS

+0.00 LTS

-0.07 LTS

+0.00 LTS

+0.09 LTS

+0.00 LTS

+0.14 LTS

+0.00 LTS

+0.14 LTS

+0.00 LTS

-0.02 006

-0.45 010

+0.45 009

-0.33 014

+20.84 014

+8.98 014

+4.88 LTS

-0.04 LTS

+0.00 012

+11.14 LTS

+0.04 LTS

+0.00 LTS

+0.07 LTS

+0.00 LTS

+0.11 LTS

+0.13 LTS

+0.22 LTS

+0.20 LTS

+0.00 LTS

+0.40 LTS

-0.02 LTS

+0.45 LTS

+0.00 LTS

+0.46 LTS

+0.00 LTS

+0.51 LTS

+0.00 015

+29.98 LTS

+0.00 LTS

+0.13 LTS

+0.54 LTS

+0.09 LTS

+0.16 LTS

+0.11 LTS

+0.18 LTS

+0.13 LTS

+0.61 LTS

+0.16 LTS

+0.18 LTS

+0.11 LTS

+0.00 LTS

+0.25 LTS

+0.09 LTS

+0.18 LTS

+0.18 LTS

+0.09 LTS

+0.05 LTS

+0.02 LTS

+0.14 010

+14.27 010

+13.12 LTS

+0.09 LTS

+0.14 LTS

+0.07 LTS

-0.02 EXT EXT UTIL 1 UTIL UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 2 CAL # LEG 42 OUTLET 42 OUTLET 42 OUTLET 42 OUTLET 43 OUTLET 43 OUTLET 42 OUTLET 16 OUTLET 16 OUTLET 99 OUTLET 16 OUTLET 99 OUTLET 16 OUTLET 99 OUTLET 16 OUTLET 99 OUTLET 16 OUTLET 99 OUTLET 16 OUTLET 99 OUTLET 16 OUTLET 16 OUTLET 16 OUTLET 99 OUTLET 118 OUTLET 118 OUTLET 118 OUTLET 117 OUTLET 118 OUTLET 117 OUTLET 117 OUTLET 118 OUTLET 117 OUTLET 118 OUTLET 117 OUTLET 151 OUTLET 150 OUTLET 151 OUTLET 150 OUTLET 150 OUTLET 151 OUTLET 151 OUTLET 150 OUTLET 150 OUTLET 151 OUTLET 151 OUTLET 150 OUTLET 150 OUTLET 150 OUTLET 42 OUTLET 43 OUTLET 43 OUTLET 42 OUTLET 43 OUTLET 42 OUTLET 12 OUTLET 12 OUTLET 15 OUTLET 12 OUTLET 15 OUTLET 12 OUTLET 15 OUTLET 12 OUTLET 15 OUTLET 15 OUTLET 15 OUTLET 15 OUTLET 15 OUTLET 15 OUTLET 15 OUTLET 15 OUTLET 15 OUTLET 15 OUTLET 15 OUTLET 15 OUTLET PROBE 51OUL 51OUL 51OUL 51OUL 510UL 51OUL 51OUL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 51OUL 510UL 51OUL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 51OUL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510UL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:15:03 Component: S/G A Page 44 of 56 ATTACHMENT #1 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW 102 102 102 102 102 102 102 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 103 104 104 104 104 104 104 104 104 104 104 104 104 104 104 TUBE VOLTS 87 0.34 92 0.27 102 0.28 105 0.49 109 0.43 0.42 113 0.25 122 0.54 3

1.73 13 1.52 17 0.43 21 0.17 36 18.22 49 9.69 50 17.38 51 0.28 0.25 20.47 52 14.47 53 15.37 0.36 54 21.75 55 23.23 56 30.43 57 15.57 58 14.89 59 13.05 60 30.00 10.22 61 17.37 62 40.19 63 27.71 64 23.46 65 23.36 66 19.72 67 20.55 68 32.85 69 31.31 10.61 70 7.39 16.88 71 20.53 72 0.49 32.34 73 23.40 74 21.11 75 26.16 76 36.25 77 35.50 78 36.77 79 53.56 80 41.00 81 48.99 82 27.27 83 12.45 84 6.74 104 0.59 111 0.76 123 0.52 124 8.38 3

0.16 12 0.54 14 0.30 49 8.78 50 17.61 52 20.21 53 13.81 54 17.86 55 24.96 56 32.45 57 0.27 20.02 58 17.60 59 13.70 60 17.35 DEG CHN IND 113 3 NQI 84 3

NQI 108 3 NQI 79 3

NQI 100 3 NQI 92 3

NQI 80 3

NQI 96 P 1 NQI 103 P 1 NQI 107 3 NQI 99 P 1 NQI 97 3

NQI 107 3 NQI 181 P 1 DNT 179 P 1 DNT 96 3

NQI 95 3

NQI 180 P 1 DNT 179 P 1 DNT 179 P 1 DNT 104 3 NQI 177 P 1 DNT 178 P 1 DNT 182 P 1 DNT 175 P 1 DNT 178 P 1 DNT 172 P 1 DNT 178 P 1 DNT 183 P 1 DNT 174 P 1 DNT 179 P 1 DNT 180 P 1 DNT 181 P 1 DNT 179 P 1 DNT 178 P 1 DNT 180 P 1 DNT 179 P 1 DNT 181 P 1 DNT 176 3 DNT 184 P 1 DNT 178 P 1 DNT 179 P 1 DNT 107 3 NQI 180 P 1 DNT 180 P 1 DNT 180 P 1 DNT 178 P 1 DNT 179 P 1 DNT 179 P 1 DNT 179 P 1 DNT 181 P 1 DNT 181 P 1 DNT 181 P 1 DNT 181 P 1 DNT 180 P 1 DNT 181 P 1 DNT 104 3 NQI 98 P 1 NQI 115 3 NQI 186 P 1 DNT 85 3

NQI 110 P 1 NQI 110 3 NQI 177 P 1 DNT 180 P 1 DNT 179 P 1 DNT 178 P 1 DNT 180 P 1 DNT 174 P 1 DNT 183 P 1 DNT 74 3

NQI 173 P 1 DNT 179 P 1 DNT 170 P 1 DNT 177 P 1 DNT

%TW LOCATION 004 006 2

014 004 012 H

LTS H

011 H

010 010

+

LTS H

004 011

+

LTS H

LTS LTS H

008 H

008 H

LTS H

LTS H

LTS H

LTS

+

LTS

+

LTS 4

LTS LTS

+

LTS

+

LTS H

LTS H

LTS H

LTS 4

LTS 4

LTS

+

LTS 4

LTS 4

LTS 4

LTS 4

LTS 4

LTS 4

LTS 4

LTS 4

LTS 4

LTS 4

004

+

LTS

+

LTS

+

LTS

+

LTS

+

LTS

+

LTS

+

LTS

+

LTS

+

LTS

+

LTS

+

LTS

+

LTS LTS 002

+

013

+

012

+

UTS

+

010

+

008 014

+

LTS

+

LTS

+

LTS

+

LTS

+

LTS

+

LTS

+

LTS

+

010

+

LTS

+

LTS 4

LTS

+

LTS

+

+13.35

+28.04

+19.97

+26.83

+4.66 r19.93

+29.56

-0.72

-0.59

-20.90 TO+29.58

-0.83

-2.26

-22.22 TO+29.54

-0.16

-0.00

-35.41

-24.15

-0.00

-0.07

-0.00

-10.07

-0.09

-0.13

-0.13

-0.20

-0.00

-0.00

-0.00

-0.42

-0.07

-0.00

-0.07

-0.

11

-0.09

-0.04

-0.16

-0.07

-0.07 0.63

+0.58 0.04

+0.02

+9.54 0.04 0.07 0.11

+0.09 0.16

+0.09

+0.45

+0.07 0.11 0.11 0.09

-0.04 0.13

+34.17 0.74 16.52

+0.00

+13.47 0.81

  • 29.33

+0.00 0.00

+0.00

+0.00 0.00 0.09

  • 0

.00 13.29

  • 0.00

+0.00

+0.02

+0.00 EXT UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE EXT LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTIL 1 UTIL 2 CAL #

15 16 16 15 15 15 99 16 109 109 109 109 117 118 117 118 118 118 117 118 118 117 151 150 151 150 151 150 150 151 150 42 42 42 43 42 43 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 109 109 109 109 109 109 109 109 151 150 151 151 150 151 150 LEG PROBE OUTLET 51lOUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET S5OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:15:03 Component: S/G A Page 45 of 56 ATTACHMENT #1 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW 104 104 104 104 104 104 104 104 104 104 104 104 104 104 104 104 104 104 104 104 104 104 104 104 104 104 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 TUBE VOLTS 61 0.63 23.65 62 39.69 63 24.82 64 25.71 65 24.47 66 27.64 6.46 67 30.11 68 12.29 22.10 69 6.46 15.16 70 6.23 13.99 71 15.09 8.86 72 41.46 73 18.15 75 40.19 76 42.89 77 51.91 78 50.88 79 46.60 80 32.60 81 13.95 82 10.77 102 0.36 112 0.42 0.49 120 1.28 122 0.67 123 7.12 15

0. 19 17 4.61 21 0.56 35 0.29 49 10.75 50 19.77 51 21.42 52 16.44 53 14.95 54 20.34 55 22.26 56 12.75 57 20.02 58 15.45 59 13.48 60 20.21 61 17.69 62 19.31 63 19.28 64 12.68 65 21.40 66 23.01 67 23.15 68 6.33 14.33 69 10.89 7.72 70 10.45 8.20 71 12.05 10.13 72 26.92 73 33.16 74 26.39 75 40.34 76 44.65 78 40.48 79 19.79 7.75 103 0.41 105 0.41 108 0.30 DEG CHN IND 102 3 NQI 172 P 1 DNT 179 P 1 DNT 179 P 1 DNT 178 P 1 DNT 180 P 1 DNT 178 P 1 DNT 177 P 1 DNT 180 P 1 DNT 181 P 1 DNT 179 P 1 DNT 182 P 1 DNT 178 P 1 DNT 182 P 1 DNT 177 P 1 DNT 179 P 1 DNT 181 P 1 DNT 181 P 1 DNT 178 P 1 DNT 180 P 1 DNT 180 P 1 DNT 180 P 1 DNT 181 P 1 DNT 180 P 1 DNT 180 P 1 DNT 179 P 1 DNT 182 P 1 DNT 96 3

NQI 94 P 1 NQI 99 P 1 NQI 97 P 1 NQI 110 P 1 NQI 10 P 1 NQI 90 3

NQI 116 3 NQI 89 P 1 NQI 99 3

NQI 180 P 1 DNT 180 P 1 DNT 179 P 1 DNT 180 P 1 DNT 180 P 1 DNT 179 P 1 DNT 176 P 1 DNT 172 P 1 DNT 183 P 1 DNT 177 P 1 DNT 182 P 1 DNT 172 P 1 DNT 178 P 1 DNT 179 P 1 DNT 180 P 1 DNT 177 P 1 DNT 174 P 1 DNT 178 P 1 DNT 179 P 1 DNT 359 P 1 DNT 178 P 1 DNT 181 P 1 DNT 178 P 1 DNT 182 P 1 DNT 177 P 1 DNT 179 P 1 DNT 172 P 1 DNT 178 P 1 DNT 178 P 1 DNT 180 P 1 DNT 180 P 1 DNT 179 P 1 DNT 181 P 1 DNT 180 P 1 DNT 181 3 DNT 81 3

NQI 78 3

NQI 98 3

NQI

%TW LOCATION EXT 015

+30.35 UTE LTS

+0.04 UTE LTS

+0.00 UTE LTS

+0.00 UTE LTS

+0.04 UTE LTS

+0.07 UTE LTS

+0.07 UTE LTS

+0.47 UTE LTS

+0.00 UTE LTS

+0.45 UTE LTS

+0.07 UTE LTS

+0.38 UTE LTS

-0.02 UTE LTS

+0.36 UTE LTS

-0.07 UTE LTS

-0.02 UTE LTS

+0.38 UTE LTS

-0.02 UTE LTS

+0.13 UTE LTS

+0.16 UTE LTS

+0.11 UTE LTS

+0.09 UTE LTS

+0.00 UTE LTS

+0.11 UTE LTS

+0.00 UTE LTS

-0.04 UTE LTS

-0.22 UTE 012

+20.82 UTE 015

+0.02 UTE 015

+0.40 UTE 009

-0.64 UTE 010

-0.60 UTE UTS

-0.29 UTE 014

+1.19 UTE LTS

+21.58 TO+30.08 UTE LTS

-0.36 UTE 009

+5.72 UTE LTS

+0.00 UTE LTS

+0.00 UTE LTS

+0.00 UTE LTS

+0.00 UTE LTS

+0.00 UTE LTS

+0.00 UTE LTS

+0.09 UTE LTS

+0.13 UTE LTS

+0.00 UTE LTS

+0.11 UTE LTS

+0.00 UTE LTS

+0.09 UTE LTS

+0.00 UTE LTS

+0.00 UTE LTS

-0.02 UTE LTS

+0.02 UTE LTS

+0.00 UTE LTS

-0.05 UTE LTS

+0.04 UTE LTS

+0.36 UTE LTS

+0.02 UTE LTS

+0.38 UTE LTS

+0.02 UTE LTS

+0.40 UTE LTS

-0.02 UTE LTS

+0.34 UTE LTS

+0.02 UTE LTS

+0.18 UTE LTS

+0.13 UTE LTS

+0.04 UTE LTS

+0.11 UTE LTS

+0.13 UTE LTS

+0.02 UTE LTS

-0.28 UTE LTE

+2.26 UTE 015

+37.15 UTE 015

+15.41 UTE 010

+11.83 UTE EXT LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTIL 1 UTIL 2 CAL 4 151 151 150 42 43 42 43 43 42 8

8 8

8 8

8 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 109 109 109 109 109 109 109 109 109 109 151 151 150 151 150 151 150 42 42 42 43 8

8 8

8 8

8 8

8 8

8 8

8 8

8 8

8 8

8 8

8 8

LEG OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET PROBE 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:15:03 Component: S/G A Page 46 of 56 ATTACHMENT #1 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW TUBE VOLTS 14.04 106 49 10.71 106 50 12.12 106 51 24.16 106 52 22.40 106 53 18.54 106 54 13.16 106 55 19.64 106 56 18.71 106 57 32.10 106 58 9.53 106 59 13.65 106 62 10.73 106 63 13.03 106 64 14.85 106 65 17.49 106 66 7.63 106 67 13.23 106 68 14.68 106 69 21.65 106 70 26.84 106 71 22.22 106 72 25.91 106 73 25.19 106 74 22.47 106 75 19.53 106 76 9.62 106 82 0.26 106 84 0.28 106 105 0.37 106 110 0.22 107 45 0.24 107 46 0.30 107 48 0.29 107 50 8.97 107 51 13.53 107 52 15.16 107 53 8.07 107 54 10.91 107 55 14.12 107 56 9.78 107 57 12.58 107 58 0.84 11.08 107 59 15.36 107 60 15.33 107 61 0.44 0.46 0.31 12.17 0.95 107 62 16.35 107 63 17.15 107 65 18.16 107 66 15.90 107 67 20.04 107 68 10.60 107 69 8.56 107 70 14.67 107 71 19.02 107 72 14.83 107 73 12.82 107 74 18.43 107 75 11.45 107 76 6.25 107 78 10.02 107 104 0.29 7.43 107 107 0.26 107 117 0.30 107 118 7.08 8.53 14.40 107 120 1.54 0.47 DEG 179 180 180 179 180 179 177 175 172 182 175 180 169 181 178 180 183 177 168 175 174 181 179 180 174 175 171 101 99 90 84 95 95 95 180 180 180 179 173 177 177 176 102 177 174 180 93 94 95 173 113 178 177 189 184 185 178 183 174 180 181 179 176 172 165 179 83 178 103 112 180 179 180 78 91 CHN IND %TW 3

DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT 3

NQI 3

NQI 3

NQI P 1 NQI P 1 NQI 3

NQI 3

NQI P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT 3

NQI P 1 DNT P 1 DNT P 1 DNT 3

NQI 3

NQI 3

NQI P 1 DNT 3

NQI P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT P 1 DNT 3

DNT 3

NQI 3

DNT 3

NQI P 1 NQI 3

DNT 3

DNT 3

DNT 3

NQI 3

NQI LOCATION LTE

+6.07 LTS

+0.00 LTS

+0.00 LTS

+0.00 LTS

+0.00 LTS

+0.00 LTS

+0.00 LTS

+0.00 LTS

+0.11 LTS

+0.00 LTS

-0.02 LTS

+0.00 LTS

+0.16 LTS

+0.16 LTS

+0.07 LTS

+0.22 LTS

+0.23 LTS

+0.22 LTS

+0.13 LTS

+0.09 LTS

+0.07 LTS

+0.04 LTS

+0.11 LTS

+0.11 LTS

+0.04 LTS

-0.37 LTS

-0.37 015

+20.83 009

+27.49 011

+14.90 015

-0.02 007

-0.47 013

+3.35 007

+3.99 LTS

+0.00 LTS

+0.00 LTS

+0.00 LTS

+0.00 LTS

+0.00 LTS

+0.00 LTS

+0.00 LTS

+0.00 LTS

+4.16 LTS

+0.07 LTS

+0.07 LTS

+0.00 014

+7.05 014

+6.28 012

+31.63 LTS

-0.07 004

+6.27 LTS

+0.00 LTS

+0.04 LTS

+0.11 LTS

+0.11 LTS

+0.16 LTS

+0.13 LTS

+0.18 LTS

+0.11 LTS

+0.07 LTS

+0.09 LTS

+0.07 LTS

+0.00 LTS

+0.02 LTS

+0.05 LTE

+3.73 009

+3.81 LTE

+6.31 011

+22.67 010

-0.11 LTE

+6.03 LTE

+4.62 LTE

+3.52 014

+33.44 014

+33.02 EXT UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE EXT LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTIL 1 UTIL 2 CAL # LEG 8

OUTLET 105 OUTLET 105 OUTLET 105 OUTLET 105 OUTLET 105 OUTLET 105 OUTLET 105 OUTLET 151 OUTLET 150 OUTLET 151 OUTLET 150 OUTLET 8

OUTLET 8

OUTLET 8

OUTLET 8

OUTLET 8

OUTLET 8

OUTLET 8

OUTLET 8

OUTLET 8

OUTLET 8

OUTLET 8

OUTLET 8

OUTLET 8

OUTLET 8

OUTLET 8

OUTLET 8

OUTLET 8

OUTLET 8

OUTLET 8

OUTLET 105 OUTLET 105 OUTLET 105 OUTLET 105 OUTLET 105 OUTLET 105 OUTLET 105 OUTLET 105 OUTLET 105 OUTLET 105 OUTLET 105 OUTLET 105 OUTLET 105 OUTLET 151 OUTLET 150 OUTLET 8

OUTLET 8

OUTLET 8

OUTLET 8

OUTLET 8

OUTLET 8

OUTLET 8

OUTLET 8

OUTLET 8

OUTLET 8

OUTLET 8

OUTLET 8

OUTLET 8

OUTLET 8

OUTLET 8

OUTLET 8

OUTLET 8

OUTLET 8

OUTLET 8

OUTLET 8

OUTLET 8

OUTLET 8

OUTLET 8

OUTLET 8

OUTLET 8

OUTLET 8

OUTLET 8

OUTLET 8

OUTLET 8

OUTLET PROBE 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 5lOUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:15:04 Component: S/G A Page 47 of 56 ATTACHMENT #1 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW TUBE VOLTS 0.57 0.24 0.34 108 4 0.75 108 15 0.36 108 41 0.57 108 50 8.07 108 51 12.92 108 52 11.30 108 53 12.58 108 54 10.14 108 55 12.76 108 56 9.26 108 57 7.41 108 58 11.72 108 59 9.91 108 60 8.70 108 61 8.22 108 62 10.55 108 63 22.98 108 64 21.03 108 65 17.81 108 66 14.34 108 67 10.63 108 68 8.08 108 69 15.06 108 70 18.92 108 71 18.77 108 72 19.26 108 73 17.61 108 74 6.14 108 91 0.54 0.32 0.59 108 100 0.36 108 108 0.31 108 111 13.77 109 4 0.44 109 45 6.03 109 50 7.39 0.24 0.40 0.41 0.19 109 51 10.43 109 52 13.59 109 53 10.75 109 54 8.45 0.55 0.36 109 55 8.95 109 56 9.61 109 57 11.83 109 58 0.54 9.23 109 59 6.92 109 60 7.29 109 61 7.53 109 62 17.40 109 63 10.96 109 64 25.57 109 65 20.39 109 66 23.08 109 67 13.66 109 68 11.99 109 69 15.59 109 70 13.55 109 71 13.19 109 72 9.74 109 78 0.31 109 88 0.60 109 93 6.00 109 107 0.34 109 110 0.22 0.33 DEG 91 85 103 101 99 69 178 180 180 176 172 180 180 183 182 178 181 178 178 179 177 180 179 178 176 177 173 177 175 179 180 99 92 100 64 76 66 59 179 180 88 86 98 100 175 177 172 179 99 90 185 182 180 99 181 170 179 179 178 179 177 179 177 179 178 178 175 180 178 95 88 90 95 112 107 CHN 3

3 3

P 1 3

3 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P I P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 3

3 3

P 1 3

P1 P 1 P 1 P 1 3

3 3

P1 P 1 P 1 P 1 P 1 3

3 P1 P 1 P 1 3

P 1 P 1 P 1 P 1 P 1 P 1 P I P 1 P I P 1 P 1 P I P 1 P 1 P 1 3

3 6

3 3

3 IND NQI NQI NQI NQI NQI NQI DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT NQI NQI NQI NQI NQI TWD NQI DNT DNT NQI NQI NQI NQI DNT DNT DNT DNT NQI NQI DNT DNT DNT NQI DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT NQI NQI ADI NQI NQI NQI

%TW LOCATION 014

+32.35 010

+10.81 002

+10.74 009

-0.59 015

+14.72 012

+8.72 LTS

+0.00 LTS

+0.00 LTS

+0.00 LTS

-0.02 LTS

+0.00 LTS

+0.00 LTS

+0.00 LTS

+0.14 LTS

+0.00 LTS

+0.00 LTS

+0.00 LTS

+0.00 LTS

+0.00 LTS

+0.00 LTS

+0.07 LTS

+0.00 LTS

+0.02 LTS

-0.07 LTS

+0.00 LTS

-0.02 LTS

+0.02 LTS

-0.04 LTS

+0.05 LTS

-0.04 LTS

+0.00 015

+24.93 012

+8.33 009

+7.64 010

-0.20 013

+15.02 75 010

+0.75 015

-0.71 LTS

+0.02 LTS

+0.07 010

+14.41 010

+25.51 TO+32.98 011

+12.14 015

+0.39 LTS

+0.07 LTS

+0.07 LTS

+0.16 LTS

+0.13 012

+33.64 006

+32.43 LTS

+0.16 LTS

+0.13 LTS

+0.07 013

+14.92 LTS

+0.02 LTS

+0.07 LTS

+0.00 LTS

+0.00 LTS

-0.02 LTS

+0.00 LTS

+0.02 LTS

+0.00 LTS

+0.05 LTS

+0.00 LTS

-0.02 LTS

+0.00 LTS

+0.05 LTS

+0.00 LTS

+0.00 008

+12.43 002

+13.73 001

+12.41 TO+20.71 015

+2.61 010

+23.27 010

+21.88 EXT UTE UTE UTE LTE LTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE EXT LTE LTE LTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTIL 1 UTIL 2

==

CAL 8

8 8

79 79 105 105 105 105 105 105 100 99 100 99 100 150 6

7 6

7 6

7 6

7 6

7 6

7 6

99 8

8 8

8 8

9 79 79 79 79 79 79 79 79 79 79 79 79 79 79 79 79 79 79 79 6

6 7

6 7

6 7

6 7

6 7

6 7

7 7

6 6

7 7

LEG OUTLET OUTLET OUTLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET PROBE 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL S5OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 5lOUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 5lOUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:15:04 Component: S/G A Page 48 of 56 ATTACHMENT #1 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW TUBE VOLTS 0.32 0.25 109 112 0.49 0.28 109 113 0.31 0.20 109 117 10.31 110 7 0.34 110 45 6.44 110 51 6.37 110 52 6.42 110 53 7.63 110 54 8.50 110 55 0.27 8.30 110 56 6.60 110 57 8.92 110 58 0.33 0.36 110 62 14.59 7.53 110 63 6.95 110 64 12.87 110 65 17.18 110 66 11.56 110 67 7.89 110 68 7.65 110 69 6.76 110 105 0.79 110 117 18.50 12.99 2.67 111 2 0.24 111 11 0.28 111 53 7.33 111 54 7.10 111 55 6.93 111 58 6.08 0.49 111 59 6.02 111 63 6.24 111 65 6.03 111 85 1.14 111 111 1.52 111 116 10.34 112 2 0.19 7.02 112 16 0.30 112 18 0.33 112 25 0.25 112 49 6.24 112 53 7.47 112 55 6.24 112 60 6.67 112 112 0.38 112 116 0.61 113 2 0.24 13.83 14.27 113 27 0.33 113 34 1.18 113 35 0.31 113 44 0.29 113 53 7.66 113 55 6.02 113 57 6.98 113 59 7.00 113 63 6.28 113 93 0.23 113 95 0.42 113 103 0.53 113 112 0.34 114 1 7.87 114 2 0.31 114 4 0.33 DEG 104 87 103 99 93 97 180 77 180 180 176 178 179 112 180 178 178 108 98 183 180 172 180 176 180 175 178 169 82 186 189 63 83 63 180 181 178 175 70 177 174 178 118 87 11 107 175 92 97 91 179 179 178 178 111 99 109 183 184 96 19 94 84 180 177 179 173 176 105 89 96 85 178 106 104 CHN 3

3 3

P 1 3

3 3

P 1 P 1 P 1 P1 P1 P 1 3

P 1 P 1 P 1 3

3 3

P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 6

3 3

P1 P 1 P 1 P 1 P 1 P 1 P1 P 1 3

P 1 3P1 3

3 3

P 1 P 1 P 1 P 1 P 1 3

P 1 3

3 3

3 P 1 3

3 P 1 P 1 P 1 P 1 P 1 3

3 P 1 P1 3

3 3

IND TWD NQI NQI NQI NQI NQI DNT NQI DNT DNT DNT DNT DNT DNT NNT DNT NQI NQI DNT DNT DNT DNT DNT DNT DNT DNT DNT TWD DNT DNT ADI NQI NQI DNT DNT DNT DNT NQI DNT DNT DNT NQI TWD BLG NQI DNT NQI NQI NQI DNT DNT DNT DNT NQI NQI NQI DNT DNT NQI NQI NQI NQI DNT DNT DNT DNT DNT NQI NQI NQI NQI DNT NQI NQI

%TW LOCATION 24 010

+18.62 011

+3.34 010

+1.19 012

+0.94 002

+27.85 010

+28.49 LTE

+2.64 014

+0.17 LTS

-0.04 LTS

+0.00 LTS

+0.00 LTS

+0.00 LTS

-0.15 008

+4.23 LTS

+0.00 LTS

-0.11 LTS

+0.00 015

+14.53 007

+8.44 007

+18.21 LTS

-0.06 LTS

-0.04 LTS

-0.19 LTS

-0.02 LTS

-0.11 LTS

-0.22 LTS

-0.30 LTS

-0.33 46 014

+1.02 UTS

+0.04 015

+0.36 015

+32.48 011

+10.56 002

+14.07 LTS

+0.02 LTS

-0.20 LTS

+0.00 LTS

+0.00 015

+1.00 LTS

-0.24 LTS

-0.25 LTS

-0.30 UTS

+14.05 34 012

+1.02 UTS

-0.20 002

+33.80 LTE

+10.59 012

+22.72 011

+8.99 015

+0.17 LTS

+0.00 LTS

+0.00 LTS

+0.00 LTS

-0.22 012

+1.05 014

-1.04 012

+24.44 LTE

+5.43 LTE

+3.28 014

+3.88 010

-0.16 011

+4.84 008

+27.82 LTS

+0.00 LTS

+0.00 LTS

+0.00 LTS

-0.02 LTS

-0.28 012

+19.45 009

+2.02 014

+0.71 012

+1.08 LTE

+10.93 015

+39.22 011

+11.18 EXT UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE EXT LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTIL 1 UTIL 2 CAL # LEG PROBE 7

OUTLET 51OUL 7

OUTLET 51OUL 6

OUTLET 51OUL 6

OUTLET 51OUL 6

OUTLET 51OUL 6

OUTLET 51OUL 6

OUTLET 51OUL 93 OUTLET 51OUL 94 OUTLET 51OUL 93 OUTLET 51OUL 94 OUTLET 51OUL 93 OUTLET 51OUL 94 OUTLET 51OUL 93 OUTLET 51OUL 93 OUTLET 51OUL 94 OUTLET 51OUL 93 OUTLET 51OUL 94 OUTLET 51OUL 94 OUTLET 51OUL 62 OUTLET 51OUL 62 OUTLET 51OUL 63 OUTLET 51OUL 62 OUTLET 51OUL 63 OUTLET 51OUL 62 OUTLET 51OUL 63 OUTLET 51OUL 62 OUTLET 51OUL 63 OUTLET 51OUL 62 OUTLET 51OUL 63 OUTLET 51OUL 63 OUTLET 51OUL 63 OUTLET 51OUL 93 OUTLET 51OUL 93 OUTLET 51OUL 93 OUTLET 51OUL 94 OUTLET 51OUL 93 OUTLET 51OUL 93 OUTLET 51OUL 93 OUTLET 51OUL 62 OUTLET 51OUL 62 OUTLET 51OUL 62 OUTLET 51OUL 62 OUTLET 51OUL 62 OUTLET 51OUL 63 OUTLET 51OUL 93 OUTLET 51OUL 93 OUTLET 51OUL 94 OUTLET 51OUL 94 OUTLET 51OUL 93 OUTLET 51OUL 93 OUTLET 51OUL 93 OUTLET 51OUL 93 OUTLET 51OUL 62 OUTLET 51OUL 63 OUTLET 51OUL 62 OUTLET 51OUL 94 OUTLET 51OUL 94 OUTLET 51OUL 94 OUTLET 51OUL 93 OUTLET 51OUL 94 OUTLET 51OUL 93 OUTLET SlOUL 94 OUTLET 51OUL 93 OUTLET 51OUL 93 OUTLET 51OUL 93 OUTLET 51OUL 62 OUTLET 51OUL 62 OUTLET 51OUL 63 OUTLET 51OUL 63 OUTLET 51OUL 63 OUTLET 51OUL 62 OUTLET 51OUL 94 OUTLET 51OUL 93 OUTLET 51OUL 94 OUTLET S5OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3

12/05/01 14:15:05 Component: S/G A Page 49 of 56 ATTACHMENT #1 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW 114 114 114 114 114 114 114 114 114 114 114 114 114 114 114 115 115 115 115 115 115 115 116 116 116 116 116 116 117 117 117 117 117 117 117 118 118 118 118 118 118 118 118 118 119 119 119 119 119 119 119 120 120 120 120 120 121 121 121 121 121 121 121 121 121 121 121 121 TUBE VOLTS 6

0.29 21 0.29 47 0.47 51 8.48 52 0.38 0.37 56 6.47 58 6.64 59 6.07 62 0.44 95 0.33 102 9.55 103 0.66 110 0.48 114 0.60 0.45 115 0.65 13 0.19 0.20 46 19.56 56 6.44 61 0.62 66 0.47 102 0.66 114 6.03 21 0.64 77 0.34 98 0.48 104 0.44 107 0.53 111 9.39 10 0.26 20 0.68 45 0.25 49 0.67 89 0.75 90 1.03 107 0.40 3

0.53 20 0.38 21 0.44 77 0.26 83 0.32 90 0.50 100 0.53 101 0.59 105 0.41 19 0.21 24 0.39 44 0.22 45 0.40 55 0.60 84 0.31 99 0.43 5

0.33 49 0.30 55 0.36 0.57 0.30 58 0.28 0.30 69 0.52 5

0.84 21 0.42 0.27 33 0.26 41 0.70 42 0.36 45 0.24 48 0.98 50 0.40 54 0.52 66 0.29 79 0.40 80 0.20 DEG 102 93 54 183 39 80 179 181 179 104 103 181 95 104 69 85 110 104 68 179 179 93 102 83 172 86 77 110 102 91 195 86 82 84 73 84 79 112 77 87 101 75 91 74 75 80 105 94 96 91 103 75 93 98 101 85 84 62 84 107 82 105 119 87 85 111 66 98 75 83 90 56 91 83 67 CHN IND 3

NQI 3

NQI P 1 NQI 3

DNT P 1 NQI P 1 NQI P 1 DNT P 1 DNT P 1 DNT 3

NQI 3

NQI 3

DNT P 1 NQI P 1 NQI P 1 NQI P 1 NQI 3

NQI 3

NQI P 1 NQI 3

DNT P 1 DNT P 1 NQI 3

NQI 3

NQI 3

DNT P 1 NQI 3

NQI 3

NQI 3

NQI P 1 NQI P 1 DNT 3

NQI P 1 NQI 3

NQI P 1 NQI P 1 NQI P 1 NQI 3

NQI P 1 NQI P 1 NQI 3

NQI 3

NQI 3

NQI 3

NQI 3

NQI P 1 NQI 3

TWD 3

NQI 3

NQI 3

NQI 3

NQI P 1 NQI 3

NQI P 1 NQI 3

NQI 3

NQI 3

NQI 3

NQI 3

NQI 3

NQI 3

NQI 3

NQI P 1 NQI 3

NQI 3

NQI 3

NQI P 1 NQI 3

NQI P 1 NQI P 1 NQI 3

NQI P 1 NQI 3

NQI 3

NQI P 1 NQI

%TW LOCATION 014

+31.44 010

+30.57 004

-0.18 001

+6.34 014

+0.28 014

+0.57 LTS

+0.00 LTS

-0.04 LTS

-0.02 015

+39.67 015

+29.66 LTE

+4.72 014

+0.99 009

-0.62 010

+0.62 014

+0.77 010

+7.84 015

+3.29 014

+0.16 LTE

+4.61 LTS

-0.04 004

-0.70 010

+26.17 002

+10.13 LTS

+0.69 014

+0.45 003

+21.19 007

+34.14 012

+6.12 009

-0.59 UTS

+0.04 010

+4.30 015

+0.46 015

+18.00 015

+0.72 015

+0.40 015

+0.53 010

+19.49 009

-0.70 UTS

+3.09 010

+14.27 015

+30.51 008

+36.70 011

+32.85 010

+14.05 009

-0.74 20 012

+26.43 011

+36.19 008

+6.59 013

+2.65 006

+29.71 003

+0.51 001

+7.04 008

+0.54 014

+33.07 008

+18.56 012

+5.38 011

+2.51 010

+19.41 012

+23.73 012

+23.24 003

+35.98 010

+0.50 010

+8.30 008

+7.02 007

+25.01 UTS

+15.67 007

+34.84 014

+0.20 LTS

-0.33 002

+10.07 003

+1.12 009

+6.26 006

+36.37 014

+1.50 EXT UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE EXT LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTIL 1 UTIL 2 CAL # LEG PROBE 94 OUTLET 51OUL 94 OUTLET 51OUL 94 OUTLET 51OUL 94 OUTLET 51OUL 93 OUTLET 51OUL 93 OUTLET 51OUL 93 OUTLET 51OUL 93 OUTLET 51OUL 62 OUTLET 51OUL 63 OUTLET 51OUL 63 OUTLET 51OUL 62 OUTLET 51OUL 63 OUTLET 51OUL 62 OUTLET 51OUL 58 OUTLET 51OUL 58 OUTLET 51OUL 59 OUTLET 51OUL 94 OUTLET 51OUL 94 OUTLET 51OUL 93 OUTLET 51OUL 93 OUTLET 51OUL 58 OUTLET 51OUL 59 OUTLET 51OUL 58 OUTLET 51OUL 59 OUTLET 51OUL 93 OUTLET 51OUL 59 OUTLET 51OUL 58 OUTLET 51OUL 58 OUTLET 51OUL 58 OUTLET 51OUL 58 OUTLET 51OUL 92 OUTLET 51OUL 123 OUTLET 51OUL 91 OUTLET 51OUL 91 OUTLET 51OUL 58 OUTLET 51OUL 58 OUTLET 51OUL 59 OUTLET 51OUL 92 OUTLET 51OUL 91 OUTLET 51OUL 92 OUTLET 51OUL 59 OUTLET 51OUL 59 OUTLET 51OUL 58 OUTLET 51OUL 58 OUTLET 51OUL 59 OUTLET 51OUL 58 OUTLET 51OUL 90 OUTLET 51OUL 89 OUTLET 51OUL 92 OUTLET 51OUL 91 OUTLET 51OUL 58 OUTLET 51OUL 58 OUTLET 51OUL 59 OUTLET 51OUL 89 OUTLET 51OUL 86 OUTLET 51OUL 58 OUTLET 51OUL 58 OUTLET 51OUL 58 OUTLET 51OUL 59 OUTLET 51OUL 59 OUTLET 51OUL 58 OUTLET 51OUL 85 OUTLET 51OUL 85 OUTLET 51OUL 85 OUTLET 51OUL 85 OUTLET 51OUL 85 OUTLET 51OUL 86 OUTLET 51OUL 85 OUTLET 51OUL 86 OUTLET 51OUL 86 OUTLET 51OUL 58 OUTLET 51OUL 58 OUTLET 51OUL 59 OUTLET 51OUL 58 OUTLET 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:15:05 Component: S/G A Page 50 of 56 ATTACHMENT #1 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW TUBE VOLTS 0.40 121 81 0.39 121 83 8.62 11.97 21.83 15.69 121 85 10.55 18.76 9.53 40.36 121 87 0.25 121 101 0.95 16.71 16.51 122 4 0.84 0.45 122 8 0.28 122 18 0.30 122 37 0.30 122 56 0.28 122 77 0.22 122 79 0.31 122 85 0.48 122 92 0.37 122 93 0.27 122 94 0.32 122 99 0.38 0.36 122 101 0.34 123 1 1.26 123 5 0.34 123 29 0.50 0.35 123 55 0.41 123 86 0.33 123 88 0.38 123 90 0.86 123 95 0.25 123 102 0.72 0.29 123 104 19.21 124 1 0.66 124 4 0.84 0.23 124 45 0.27 0.45 124 58 0.35 124 72 0.29 124 73 3.66 124 76 0.29 124 85 0.69 124 90 0.31 124 93 1.26 124 99 0.26 124 101 12.36 125 4 0.99 125 10 0.42 125 36 0.41 125 45 0.51 125 50 0.57 125 65 0.29 125 75 0.41 125 80 0.26 125 86 0.47 125 95 0.23 125 99 0.42 0.42 0.61 25.49 0.46 9.73 125 100 31.71 126 2 0.40 126 4 0.77 126 5 0.88 DEG 101 85 182 182 184 181 183 182 187 189 96 85 182 182 99 107 90 73 100 95 75 111 89 70 73 79 100 111 48 20 96 71 73 111 106 113 98 68 111 85 180 91 115 91 95 73 69 103 107 108 98 81 108 104 179 93 79 78 44 93 88 79 106 109 96 92 84 97 183 83 181 179 59 121 102 CHN 3

3 3

3 3

3 3

3 3

3 3

P 1 3

3 3

3 3

3 3

3 3

3 P 1 3

3 3

3 3

3 6

3 P1 3

3 3

3 3

3 3

3 3

P 1 P 1 3

3 3

3 3

3 3

P 1 3

3 3

3 P 1 P 1 P 1 3

3 3

3 3

3 P 1 3

3 3

3 P 1 3

3 P 1 P1I 2 1 IND %TW NQI NQI DNT DNT DNT DNT DNT DNT DNT DNT NQI NQI DNT DNT NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI ADI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI DNT NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI DNT NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI DNT NQI DNT DNT NQI NQI NQI LOCATION 011

+20.31 006

+31.82 LTE

+9.90 LTE

+7.76 LTE

+1.89 LTE

+1.33 LTE

+4.02 LTE

+2.94 LTE

+2.32 LTE

+1.59 011

+16.86 013

+0.88 LTE

+3.26 LTE

+1.56 014

+32.96 014

+31.78 LTS

+40.06 007

+24.82 LTS

+36.62 007

+15.54 001

+15.92 015

+19.43 003

-0.81 013

+24.50 011

+9.91 011

+6.12 008

+27.38 008

+25.92 011

+15.82 014

+31.05 002

+22.08 015

+0.56 012

+7.65 006

+12.93 015

+27.44 008

+32.83 UTS

+1.35 014

+30.78 014

+29.54 014

+11.05 LTS

+1.01 015

+0.27 010

+0.59 LTS

+32.78 015

+38.49 015

+39.31 012

+27.67 011

+20.07 LTS

+24.30 005

+21.30 003

-0.76 010

+8.92 LTS

+24.15 011

+9.95 LTS

+1.10 010

+0.54 001

-0.84 015

+0.59 003

+32.84 010

+33.12 013

+28.33 009

+19.69 008

+18.65 001

+10.09 015

+0.15 010

+24.85 010

+23.75 010

+23.44 LTE

+1.88 011

+0.65 LTE

+5.98 LTS

+1.34 UTS

+11.86 010

+0.57 010

+0.56 EXT UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE EXT LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTIL 1 UTIL 2 CAL # LEG 58 OUTLET 59 OUTLET 59 OUTLET 59 OUTLET 59 OUTLET 59 OUTLET 59 OUTLET 59 OUTLET 59 OUTLET 59 OUTLET 59 OUTLET 58 OUTLET 58 OUTLET 58 OUTLET 86 OUTLET 86 OUTLET 86 OUTLET 81 OUTLET 82 OUTLET 58 OUTLET 59 OUTLET 59 OUTLET 59 OUTLET 58 OUTLET 59 OUTLET 58 OUTLET 59 OUTLET 59 OUTLET 59 OUTLET 81 OUTLET 81 OUTLET 81 OUTLET 81 OUTLET 58 OUTLET 58 OUTLET 58 OUTLET 58 OUTLET 59 OUTLET 58 OUTLET 58 OUTLET 59 OUTLET 81 OUTLET 81 OUTLET 81 OUTLET 82 OUTLET 82 OUTLET 59 OUTLET 58 OUTLET 59 OUTLET 58 OUTLET 59 OUTLET 59 OUTLET 59 OUTLET 55 OUTLET 55 OUTLET 81 OUTLET 81 OUTLET 82 OUTLET 81 OUTLET 82 OUTLET 54 OUTLET 54 OUTLET 55 OUTLET 55 OUTLET 54 OUTLET 124 OUTLET 124 OUTLET 124 OUTLET 124 OUTLET 124 OUTLET 124 OUTLET 55 OUTLET 82 OUTLET 82 OUTLET 81 OUTLET PROBE 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL SOUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 5lOUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 5lOUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 5lOUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:15:06 Component: S/G A Page 51 of 56 ATTACHMENT #1 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW 126 126 127 TU 91 97 3

127 5 127 27 127 30 127 35 127 44 127 65 127 75 127 92 128 4 128 9 128 18 128 20 128 36 128 42 128 60 128 70 128 74 128 89 128 93 129 1 129 25 129 27 129 28 129 44 129 54 129 55 129 59 129 63 129 75 129 76 129 86 129 89 129 91 129 92 129 94 BE VOLTS 0.47 0.47 0.33 1.38 1.36 0.23 0.36 6.04 0.54 0.31 0.26 0.23 0.38 0.27 0.44 0.43 65.75 12.47 0.30 0.37 0.56 0.75 1.28 0.33 0.37 8.26 0.30 0.72 0.45 0.37 0.58 0.22 0.26 0.24 0.26 14.49 0.31 0.39 0.31 0.26 0.29 0.48 0.39 0.36 13.29 16.86 0.26 0.36 3.00 0.41 1.27 1.10 0.76 0.70 0.36 0.27 0.40 0.24 0.28 0.40 0.43 0.29 0.31 0.45 1.10 0.58 0.37 0.38 0.48 0.36

0. 67 0.55 0.31 0.37 0.58 DEG 47 43 84 106 100 86 124 180 97 77 62 96 93 69 121 68 176 188 75 80 109 82 53 89 94 181 85 102 98 103 67 93 68 89 75 181 85 63 116 92 112 90 97 100 182 13 102 99 114 102 111 147 146 110 54 105 86 93 60 118 95 102 93 108 102 74 93 87 93 111 128 77 107 104 97 Cl-P P

3 P

P 3

P 3

P 3

3 3

3 3

P P

3 3

3 3

3 P

3 3

3 3

3 P

P 3

3 3

3 P

3 3

3 3

3 3

3 P

3 3

3 P

3 3

3 3

3 P

P 3

P 3

P 3

3 3

P 3

3 3

P P

P 3

3 3

3 3

3 3

3 IN IND 1 NQI 1 NQI NQI 1NQI 1 NQI 1 NQI NQI 1 NQI DNT 1 NQI NQI NQI NQI NQI NQI 1 NQI 1 NQI DNT DNT NQI NQI TWD 1 NQI NQI NQI NQI DNT NQI 1 NQI 1 NQI NQI NQI NQI NQI 1 NQI NQI DNT NQI NQI NQI NQI NQI 1 NQI NQI NQI DNT 1 BLG NQI NQI NQI NQI NQI 1 NQI 1 NQI TWD 1 NQI TWD 1 NQI NQI NQI NQI 1 NQI NQI NQI NQI 1 NQI 1 NQI 1 NQI NQI NQI NQI NQI NQI NQI NQI NQI

%TW LOCATION 013

+0.98 008

+0.61 013

+1.07 015

-0.36 010

+0.59 012

+34.89 014

+0.41 015

+27.76 009

-0.82 001

+14.76 009

+5.05 008

+22.51 002

+33.09 013

+24.33 009

+0.49 010

+0.33 002

+35.29 LTS

+23.95 009

+28.14 015

+21.40 8

015

+40.92 LTS

-0.31 008

+1.09 014

+33.45 012

+27.39 LTE

+2.81 014

+31.05 015

-0.93 003

-0.77 015

+36.08 006

+35.93 013

+14.99 015

+9.14 004

-0.40 012

+16.22 006

+17.08 014

+1.19 015

+25.63 014

+10.17 013

+24.25 013

+4.03 005

-0.81 011

+6.89 010

+30.65 LTE

+3.26 UTS

-0.18 014

+20.51 014

+18.08 013

+3.09 011

+6.48 014

+31.17 010

+0.52 010

+0.57 6

011

+19.24 002

-1.18 24 009

+9.07 014

+0.45 001

+2.51 008

+6.26 003

+36.02 004

+0.78 009

+23.60 002

+26.29 008

+32.63 015

-0.22 009

+0.34 014

+0.93 015

+40.96 015

+14.81 008

+18.40 008

+1.25 011

+35.31 013

+8.91 013

+4.43 012

+9.72 TO+28.42 EXT UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE EXT LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTIL 1 UTIL 2

==

CAL # LEG PROBE 55 OUTLET 51OUL 55 OUTLET 51OUL 75 OUTLET 51OUL 75 OUTLET 51OUL 75 OUTLET 51OUL 75 OUTLET 51OUL 74 OUTLET 51OUL 74 OUTLET 51OUL 75 OUTLET 51OUL 74 OUTLET 51OUL 55 OUTLET 51OUL 55 OUTLET 51OUL 55 OUTLET 51OUL 55 OUTLET 51OUL 54 OUTLET 51OUL 74 OUTLET 51OUL 158 INLET 50OUL 74 OUTLET 51OUL 74 OUTLET 51OUL 74 OUTLET 51OUL 74 OUTLET 51OUL 54 OUTLET 51OUL 54 OUTLET 51OUL 54 OUTLET 51OUL 55 OUTLET 51OUL 55 OUTLET 51OUL 75 OUTLET 51OUL 75 OUTLET 51OUL 75 OUTLET 51OUL 74 OUTLET 51OUL 75 OUTLET 51OUL 54 OUTLET 51OUL 55 OUTLET 51OUL 55 OUTLET 51OUL 55 OUTLET 51OUL 55 OUTLET 51OUL 54 OUTLET 51OUL 54 OUTLET 51OUL 54 OUTLET 51OUL 55 OUTLET 51OUL 55 OUTLET 51OUL 55 OUTLET 51OUL 54 OUTLET 51OUL 54 OUTLET 51OUL 55 OUTLET 51OUL 55 OUTLET 51OUL 55 OUTLET 51OUL 55 OUTLET 51OUL 75 OUTLET 51OUL 74 OUTLET 51OUL 74 OUTLET 51OUL 74 OUTLET 51OUL 74 OUTLET 51OUL 74 OUTLET 51OUL 75 OUTLET 51OUL 75 OUTLET 51OUL 75 OUTLET 51OUL 55 OUTLET 51OUL 54 OUTLET 51OUL 55 OUTLET 51OUL 55 OUTLET 51OUL 54 OUTLET 51OUL 55 OUTLET 51OUL 54 OUTLET 51OUL 70 OUTLET 51OUL 71 OUTLET 51OUL 71 OUTLET 51OUL 70 OUTLET 51OUL 54 OUTLET 51OUL 54 OUTLET 51OUL 55 OUTLET 51OUL 54 OUTLET 51OUL 55 OUTLET 51OUL 55 OUTLET SOUL 55 OUTLET 51OUL 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 131 131 131 131 131 131 131 131 1

2 4

6 11 12 16 26 60 69 78 84 89 90 91 2

5 36 39 68 69 80 83

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:15:06 Component: S/G A Page 52 of 56 ATTACHMENT #1 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW TUBE VOLTS 0.39 0.42 0.25 0.41 131 85 0.23 0.33 0.32 131 86 0.34 8.30 0.21 0.24 131 87 0.36 0.33 0.25 13.08 131 90 0.37 0.43 0.39 132 29 10.30 132 33 0.38 132 75 0.61 132 80 1.30 132 81 11.44 132 82 0.49 0.98 132 83 0.69 133 3 0.81 133 26 0.26 133 57 0.72 133 62 0.23 0.40 133 66 0.27 133 77 0.77 133 82 0.42 0.28 0.37 0.36 0.31 133 83 0.45 0.58 10.62 14.03 133 84 0.19 0.24 0.15 0.19 0.22 0.29 133 85 0.42 0.33 0.37 134 27 16.87 134 29 0.48 0.29 134 32 0.60 0.25 134 33 0.19 134 37 0.45 0.31 0.67 134 38 0.70 0.89 0.39 0.60 134 47 0.49 134 49 0.23 134 69 0.15 134 84 0.29 134 85 0.36 6.23 135 3 0.71 135 22 0.31 135 26 0.31 0.29 135 28 9.12 DEG CHN IND 109 3 NQI 96 3

NQI 100 3 NQI 95 3

NQI 91 3

NQI 84 3

NQI 77 3

NQI 98 3

NQI 180 3 DNT 95 3

NQI 87 3

NQI 106 3 NQI 86 3

NQI 103 3 NQI 181 3 DNT 117 P 1 NQI 122 3 NQI 106 3 NQI 181 3 DNT 64 P 1 NQI 111 3 NQI 90 P 1 NQI 185 3 DNT 110 3 NQI 72 P 1 NQI 111 P 1 NQI 36 P 1 NQI 81 3

NQI 82 P 1 NQI 83 P 1NQI 99 P 1 NQI 86 3

NQI 86 P 1 NQI 109 3 NQI 110 3 NQI 115 3 NQI 101 3 NQI 107 3 NQI 96 3

NQI 111 3 NQI 359 3 DNT 179 3 DNT 102 3 NQI 93 3

NQI 88 3

NQI 92 3

NQI 94 3

NQI 110 3 NQI 100 3 NQI 92 3

NQI 85 3

NQI 178 3 DNT 91 3

NQI 105 3 NQI 106 3 NQI 101 3 NQI 62 P 1 NQI 84 3

NQI 92,3 NQI 66 3

NQI 89 3

NQI 109 3 NQI 98 3

NQI 104 3 NQI 52 3

NQI 103 3 NQI 62 P 1 NQI 93 P 1 NQI 98 P 1 NQI 175 3 DNT 103 3 NQI 110 3 NQI 90 P 1NQI 73 3

NQI 181 3 DNT

%TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 011 010 010 009 010 010 010 012 LTE 011 011 011 011 010 LTE 007 012 011 003 014 008 008 LTE 010 009 010 007 014 LTS 015 015 015 LTS 010 010 010 009 009 014 011 LTE LTE 012 012 011 011 011 011 010 010 010 003 010 011 007 007 004 011 011 010 015 015 015 015 003 008 015 010 007 LTS 004 007 014 012 LTE

+28.21 UTE

+9.19 UTE

+8.22 UTE

+19.39 TO+38.00 UTE

+33.23 UTE

+32.36 UTE

+14.54 UTE

+4.69 TO+24.79 UTE

+3.89 UTE

+20.30 UTE

+10.34 UTE

+13.48 UTE

+4.96 UTE

+7.00 TO+12.33 UTE

+5.30 UTE

-0.63 UTE

+5.99 TO+12.15 UTE

+23.00 TO+35.00 UTE

+2.13 UTE

+0.95 UTE

+11.37 UTE

-0.82 UTE

+2.64 UTE

+9.29 TO+16.70 UTE

+0.69 UTE

+0.69 UTE

-0.75 UTE

+23.46 UTE

-0.38 UTE

-0.20 UTE

-0.61 UTE

+25.64 UTE

-0.46 UTE

+34.40 UTE

+31.28 UTE

+20.22 UTE

+37.11 UTE

+33.66 UTE

+4.16 UTE

+35.45 UTE

+2.77 UTE

+2.00 UTE

+23.05 UTE

+19.71 UTE

+24.61 UTE

+22.32 UTE

+21.11 UTE

+19.88 UTE

+30.65 UTE

+29.43 UTE

+21.67 UTE

+4.47 UTE

+16.17 UTE

+18.93 UTE

+17.45 UTE

+18.38 UTE

-0.50 UTE

+22.41 UTE

+18.64 UTE

+15.03 UTE

+40.26 UTE

+43.54 UTE

+35.32 UTE

+44.10 UTE

+14.64 UTE

+1.28 UTE

+0.27 UTE

+0.58 UTE

+0.18 UTE

+1.12 UTE

+19.29 UTE

+38.58 UTE

+0.42 UTE

+31.36 UTE

+4.95 UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 55 55 55 55 55 55 55 54 54 54 54 55 55 55 55 55 55 55 71 70 55 54 55 54 54 55 71 70 55 55 55 55 54 55 55 55 55 55 54 54 54 54 55 55 55 55 55 55 54 54 54 70 70 70 71 71 70 70 70 70 71 71 71 71 55 55 55 54 55 55 71 70 70 70 71 OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:15:07 Component: S/G A Page 53 of 56 ATTACHMENT #1 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW TUBE VOLTS 18.13 9.06 135 29 0.36 135 45 0.44 135 56 9.14 135 73 9.08 135 75 0.36 0.52 0.78 135 79 15.20 6.47 0.25 0.26 0.23 0.17 0.14 135 80 10.61 8.82 136 3 0.31 136 9 0.51 136 20 0.40 136 24 0.29 136 25 6.28 6.81 8.19 136 29 0.55 136 44 0.21 136 54 0.46 136 61 0.33 136 73 0.25 136 74 12.40 136 76 1.34 136 80 0.48 0.29 137 3 1.16 137 22 7.28 10.57 137 24 7.26 7.20 137 27 0.41 137 60 0.60 137 61 0.16 137 66 11.24 137 70 13.84 0.41 137 71 0.32 137 73 0.29 137 74 0.39 137 77 0.36 40.87 0.38 137 78 0.35 0.39 0.32 17.12 1.02 138 4 0.37 138 11 0.28 138 18 0.35 138 44 0.33 138 49 0.38 138 69 0.22 138 70 13.01 7.72 138 75 0.31 0.28 0.32 0.29 0.32 0.33 0.29 0.28 0.29 0.31 59.87 DEG 181 184 97 113 178 183 113 110 129 182 183 95 100 94 109 83 177 177 87 107 87 101 186 181 182 107 66 68 96 104 179 97 83 110 91 179 179 182 180 82 138 74 178 181 112 111 91 101 111 177 81 85 105 105 178 97 108 87 96 93 82 71 177 182 82 86 115 89 88 106 94 87 112 92 180 CHN IND 3

DUT 3

DNT 3

NQI 3

NQI 3

DNT 3

DNT 3

NQI 3

NQI 3

NQI 3

DNT 3

DNT 3

NQI 3

NQI 3

NQI 3

NQI 3

NQI 3

DNT 3

DNT P 1 NQI 3

NQI P 1 NQI 3

NQI P 1 DNT 3

DNT 3

DNT P 1 NQI 3

NQI 3

NQI 3

TWD 3

NQI 3

DNT P 1 NQI 3

NQI 3

NQI P 1 NQI 3

DNT 3

DNT 3

DNT 3

DNT 3

NQI P 1 NQI P 1 NQI 3

DNT 3

DNT 3

NQI 3

NQI 3

NQI 3

NQI 3

NQI 3

DNT P 1 NQI 3

NQI 3

NQI 3

NQI 3

DNT P 1 NQI 3

NQI 3

NQI 3

NQI P 1 NQI 3

NQI 3

NQI 3

DNT P 1 DNT 3

NQI 3

NQI 3

NQI 3

NQI 3

NQI 3

NQI 3

NQI 3

NQI 3

NQI 3

NQI P 1 DNT

%TW LOCATION LTE

+3.71 LTE

+2.41 013

+16.59 006

+33.47 LTE

+6.88 LTE

+3.33 007

+38.26 007

+25.57 007

+3.30 LTE

+5.70 LTE

+1.88 013

+18.66 013

+2.11 012

+29.00 012

+26.53 012

+25.44 LTE

+4.24 LTE

+2.70 014

-0.74 LTS

+22.90 014

+0.36 011

+33.22 003

+0.22 003

+1.64 003

+36.76 015

+0.52 010

+14.05 006

+7.84 36 009

+2.30 014

+26.35 LTE

+6.82 009

-0.73 012

+21.23 012

+22.29 010

-0.70 003

+2.12 003

+2.56 003

+1.75 003

+4.03 011

+33.18 004

-0.71 015

+0.16 LTE

+3.29 LTE

+3.40 015

+7.77 014

+27.83 014

+29.53 009

+37.66 010

+32.27 LTS

+1.53 010

+0.16 012

+28.57 011

+1.39 TO+31.09 010

+11.61 TO+28.86 LTS

+1.17 010

-0.40 001

+21.43 013

+4.99 LTS

+20.52 008

-0.18 002

+28.18 013

+18.58 009

+31.34 008

-0.27 010

+14.03 010

+31.14 010

+31.11 010

+13.94 010

+14.00 010

+31.07 010

+31.16 010

+14.06 010

+30.97 010

+13.93 LTS

+0.60 EXT UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 001 001 001 001 001 001 001 001 UTE UTE UTE EXT LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE UTE UTE LTE LTE LTE UTIL 1 UTIL 2 CAL # LEG 71 OUTLET 71 OUTLET 70 OUTLET 55 OUTLET 54 OUTLET 55 OUTLET 55 OUTLET 55 OUTLET 55 OUTLET 55 OUTLET 55 OUTLET 55 OUTLET 55 OUTLET 55 OUTLET 55 OUTLET 55 OUTLET 54 OUTLET 54 OUTLET 70 OUTLET 70 OUTLET 71 OUTLET 71 OUTLET 70 OUTLET 70 OUTLET 70 OUTLET 70 OUTLET 49 OUTLET 49 OUTLET 51 OUTLET 51 OUTLET 49 OUTLET 49 OUTLET 49 OUTLET 49 OUTLET 71 OUTLET 70 OUTLET 70 OUTLET 70 OUTLET 70 OUTLET 70 OUTLET 49 OUTLET 51 OUTLET 49 OUTLET 49 OUTLET 49 OUTLET 51 OUTLET 51 OUTLET 49 OUTLET 49 OUTLET 49 OUTLET 49 OUTLET 51 OUTLET 51 OUTLET 51 OUTLET 51 OUTLET 51 OUTLET 70 OUTLET 71 OUTLET 70 OUTLET 51 OUTLET 49 OUTLET 49 OUTLET 51 OUTLET 51 OUTLET 158 INLET 158 INLET 156 INLET 156 INLET 160 INLET 160 INLET 161 INLET 161 INLET 166 OUTLET 166 OUTLET 166 OUTLET PROBE 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 5lOUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 50OUL 50OUL 51OUL 51OUL 48 OUL 480UL 50OUL 50OUL 4800UL 480UL 480UL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:15:07 Component: S/G A Page 54 of 56 ATTACHMENT #1 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW TUBE VOLTS 36.78 13.71 7.23 139 3 0.39 139 5 0.34 139 8 0.39 139 20 0.33 0.34 139 21 0.25 139 24 7.13 12.60 23.32 13.65 84.00 139 43 0.22 139 58 0.33 139 70 0.30 0.27 140 1 0.42 0.28 0.31 140 3 0.74 140 5 0.25 140 13 0.31 140 34 0.31 0.35 140 35 0.53 140 59 0.42 140 69 16.93 140 71 0.32 0.22 15.38 141 1 0.81 141 24 8.52 25.69 9.40 14.64 18.27 10.04 6.99 10.40 12.41 7.96 11.15 16.85 10.32 9.85 6.87 36.47 49.92 31.58 141 29 0.20 141 33 0.98 141 36 0.32 141 46 0.41 141 55 0.28 0.27 141 59 0.95 141 63 1.08 141 66 0.69 141 68 6.78 142 1 0.35 142 8 0.81 142 12 0.29 142 40 0.28 142 41 0.33 142 53 0.56 142 54 0.39 142 57 0.19 142 61 0.29 143 3 0.59 143 8 0.75 143 27 0.54 0.49 143 38 0.67 DEG 177 177 179 88 105 86 80 99 98 180 180 180 170 180 68 111 108 72 115 81 72 109 91 93 96 59 75 118 182 101 86 178 94 186 179 177 179 180 180 176 180 178 178 177 178 179 177 177 179 180 180 72 56 91 83 91 82 94 104 108 181 93 99 72 93 79 51 77 97 67 81 98 77 56 76 CHN 3

3 3

P1 P 1 3

3 3

3 3

3 3

3 3

3 3

3 3

P 1 P 1 P 1 P 1 P 1 P 1 3

P 1 3

P 1 3

3 P 1 3

P 1 P1 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

P 1 P 1 P 1 3

3 P 1 P 1 3

3 3

P 1 P 1 P 1 3

3 P 1 P 1 3

P 1 P 1 P1 3

3 3

IND DNT DNT DNT NQI NQI NQI NQI NQI NQI DNT DNT DNT DNT DNT NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI DNT NQI NQI DNT NQI DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT NQI NQI NQI NQI NQI NQI NQI NQI NQI DNT NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI

%TW LOCATIC LTS LTS LTE 010 008 013 010 011 011 LTE LTE LTE LTE LTE 015 012 015 LTS 011 012 012 010 009 009 008 009 006 015 LTE UTS 014 LTS 014 LTS LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 013 010 015 001 LTS 015 008 007 007 LTE 014 008 014 013 013 008 015 012 014 014 008 013 013 003 ON

+2.81

+3.91

+3.41

+0.54

-0.38

+33.46

+31.31

+35.58

+21.43

+5.01

+3.87

+3.33

+3.08

+2.65

+4.71

+8.75

+9.20

+4.42

-0.83

-0.41

+0.38

-0.37

-0.55

+0.37

+22.28

-0.11

+19.26

+0.49

+1.97

-0.76

-0.42

+1.12

-0.68

-0.39

+22.17

+21.76

+21.50

+21.01

+20.64

+19.26

+17.71

+8.89

+8.42

+7.32

+7.02

+6.61

+5.27

+4.97

+4.15

+3.08

+1.89

+0.00

-0.92

+0.44

+2.01

+8.96

+0.31

-0.71

+9.83

+34.60

+4.43

-0.77

-0.50

+0.26

+1.46

+28.70

-0.83

+0.29

+18.54

+0.31

-0.79

+0.38

+16.96

+12.39

+22.25 EXT UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE EXT UTIL LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 1 UTIL 2 CAL # LEG PROBE 166 OUTLET 480UL 166 OUTLET 480UL 166 OUTLET 480UL 71 OUTLET 51OUL 71 OUTLET 51OUL 70 OUTLET 51OUL 71 OUTLET 51OUL 71 OUTLET 51OUL 70 OUTLET 51OUL 70 OUTLET 51OUL 70 OUTLET 51OUL 70 OUTLET 51OUL 70 OUTLET 51OUL 70 OUTLET 51OUL 51 OUTLET 51OUL 49 OUTLET 51OUL 49 OUTLET 51OUL 49 OUTLET 51OUL 71 OUTLET 51OUL 71 OUTLET 51OUL 71 OUTLET 51OUL 70 OUTLET 51OUL 70 OUTLET 51OUL 70 OUTLET 51OUL 71 OUTLET 51OUL 71 OUTLET 51OUL 70 OUTLET 51OUL 49 OUTLET 51OUL 51 OUTLET 51OUL 51 OUTLET 51OUL 51 OUTLET 51OUL 51 OUTLET 51OUL 71 OUTLET 51OUL 70 OUTLET 51OUL 70 OUTLET 51OUL 70 OUTLET 51OUL 70 OUTLET 51OUL 70 OUTLET 51OUL 70 OUTLET 51OUL 70 OUTLET 51OUL 70 OUTLET 51OUL 70 OUTLET 51OUL 70 OUTLET 51OUL 70 OUTLET 51OUL 70 OUTLET 51OUL 70 OUTLET 51OUL 70 OUTLET 51OUL 70 OUTLET 51OUL 70 OUTLET 51OUL 70 OUTLET 51OUL 70 OUTLET 51OUL 71 OUTLET 51OUL 70 OUTLET 51OUL 51 OUTLET 51OUL 51 OUTLET 51OUL 49 OUTLET 51OUL 49 OUTLET 51OUL 49 OUTLET 51OUL 49 OUTLET 51OUL 49 OUTLET 51OUL 51 OUTLET 51OUL 71 OUTLET 51OUL 70 OUTLET 51OUL 70 OUTLET 51OUL 49 OUTLET 51OUL 51 OUTLET 51OUL 51 OUTLET 51OUL 49 OUTLET 51OUL 51 OUTLET 51OUL 49 OUTLET 51OUL 70 OUTLET 51OUL 71 OUTLET 51OUL 70 OUTLET 51OUL 70 OUTLET 51OUL 49 OUTLET 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:15:08 Component: S/G A Page 55 of 56 ATTACHMENT #1 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW TUBE VOLTS 143 47 0.36 0.39 16.18 0.42 143 49 0.59 21.26 143 60 21.00 143 61 0.32 144 11 6.74 144 13 0.41 144 31 1.86 144 46 0.85 144 48 35.71 144 49 1.04 144 53 0.29 0.23 8.56 12.24 145 1 0.55 145 16 0.51 145 24 0.39 145 25 0.34 0.31 145 36 0.42 145 47 0.58 145 54 0.29 0.32 0.24 146 7 0.47 146 8 6.42 9.52 25.45 7.69 12.54 146 12 0.42 146 13 1.08 146 14 1.08 146 20 0.55 146 21 0.66 146 22 0.42 0.37 146 29 0.71 146 30 0.42 146 32 0.24 146 34 0.26 146 37 0.33 0.24 146 43 13.79 15.82 1.01 0.29 146 45 10.30 31.57 146 46 16.65 147 5 0.26 147 6 0.32 147 11 0.43 147 12 0.65 147 15 0.41 147 17 0.27 147 21 0.44 0.34 147 27 0.39 147 28 0.69 147 34 0.38 147 38 0.25 147 42 0.37 147 44 0.37 0.52 148 10 0.34 148 27 7.21 148 39 0.28 148 40 0.41 0.28 148 41 11.83 DEG 111 81 180 98 110 180 181 105 180 95 89 80 177 99 94 94 180 181 92 120 93 99 92 69 106 98 96 91 79 178 177 179 178 187 72 92 92 91 75 113 96 123 107 108 71 87 96 186 181 92 106 181 179 179 95 73 115 61 68 85 102 71 100 94 74 58 55 101 65 63 183 97 90 76 181 CHN 3

3 3

3 3

3 3

3 3

3 P 1 P1 3

P1 3

P 1 3

3 P 1 P1 P 1 3

3 P 1 P 1 3

3 3

P1 3

3 3

3 P 1 3

P 1 P1 3

P 1 3

3 P 1 3

3 3

3 3

P 1 3

P 1 P 1 3

3 3

3 3

P 1 P 1 P 1 3

3 3

P 1 P 1 3

P1 P 1 3

3 P 1 3

3 3

3 3

IND %TW NQI NQI DNT NQI NQI DNT DNT NQI DNT NQI NQI NQI DNT NQI NQI NQI DNT DNT NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI DNT DNT DNT DNT DNT NQI TWD 25 NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI DNT DNT NQI NQI DNT DNT DNT NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI DNT NQI NQI NQI DNT LOCATION 015

+31.95 013

+12.78 LTE

+3.68 013

+11.03 013

+1.26 002

+37.10 LTE

+2.48 015

+4.31 003

+2.54 011

+18.75 001

+0.75 013

+0.86 003

+2.17 008

-0.53 009

+26.27 008

+0.24 LTE

+6.41 LTE

+4.26 013

-0.78 008

-0.66 UTS

+3.42 010

+21.96 010

+18.86 014

-0.43 008

+0.40 011

+31.33 010

+32.81 TO+11.62 015

+2.59 009

+0.63 003

+3.15 003

+2.76 003

+2.04 003

+1.49 003

+0.44 001

+6.65 008

+0.74 008

-0.57 011

+13.23 008

+0.33 009

+7.91 008

+3.57 008

-0.78 008

+21.71 013

+11.82 012

+35.05 009

+33.82 009

+34.22 003

-0.86 002

+34.71 009

+0.49 009

-0.24 003

+38.59 003

+35.89 003

+3.73 015

+3.92 011

+15.43 008

+0.65 010

-0.81 005

+0.94 014

+27.16 014

+18.92 011

+29.09 009

-0.18 009

+0.47 008

+7.07 012

-0.43 009

+0.18 010

+26.01 TO+28.01 005

+29.98 008

+0.61 LTE

+3.10 010

+7.67 011

+30.64 011

+21.36 003

+4.17 EXT UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE EXT LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTIL 1 UTIL 2 CAL # LEG 49 OUTLET 49 OUTLET 49 OUTLET 49 OUTLET 49 OUTLET 49 OUTLET 51 OUTLET 49 OUTLET 70 OUTLET 70 OUTLET 49 OUTLET 49 OUTLET 49 OUTLET 49 OUTLET 49 OUTLET 49 OUTLET 49 OUTLET 49 OUTLET 71 OUTLET 70 OUTLET 70 OUTLET 71 OUTLET 71 OUTLET 51 OUTLET 49 OUTLET 51 OUTLET 51 OUTLET 51 OUTLET 71 OUTLET 70 OUTLET 70 OUTLET 70 OUTLET 70 OUTLET 70 OUTLET 70 OUTLET 71 OUTLET 70 OUTLET 71 OUTLET 70 OUTLET 66 OUTLET 66 OUTLET 49 OUTLET 49 OUTLET 49 OUTLET 49 OUTLET 49 OUTLET 49 OUTLET 49 OUTLET 49 OUTLET 49 OUTLET 49 OUTLET 49 OUTLET 49 OUTLET 51 OUTLET 67 OUTLET 66 OUTLET 66 OUTLET 66 OUTLET 66 OUTLET 67 OUTLET 67 OUTLET 67 OUTLET 123 OUTLET 49 OUTLET 49 OUTLET 124 OUTLET 51 OUTLET 49 OUTLET 49 OUTLET 67 OUTLET 123 OUTLET 49 OUTLET 49 OUTLET 49 OUTLET 124 OUTLET PROBE 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL S5OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:15:08 Component: S/G A Page 56 of 56 ATTACHMENT #1 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW TUBE VOLTS 0.39 149 1 0.31 149 8 0.54 149 15 0.38 15.09 149 16 0.77 149 25 0.60 0.37 149 30 0.45 150 3 0.53 150 5 0.52 150 8 0.52 0.58 150 9 0.64 150 11 0.58 150 12 1.27 0.72 150 14 0.64 0.39 150 19 0.67 150 20 0.41 0.26 150 22 0.35 150 27 0.53 151 3 0.31 151 4 0.42 151 5 0.84 0.44 151 7 0.46 151 9 0.25 0.46 0.25 151 12 0.36 151 13 0.32 151 14 0.60 151 15 0.47 0.45 151 16 2.44

0. 95 DEG 104 96 117 103 182 50 98 79 111 100 78 71 111 103 116 65 105 64 72 112 109 86 106 115 87 92 93 103 79 83 90 76 97 93 94 105 102 103 102 CHN IND 3

NQI 3

NQI P 1 NQI 3

NQI 3

DNT P 1 NQI P 1 NQI P 1 NQI 3

NQI 3

NQI P 1 NQI P 1 NQI P 1 NQI P 1 NQI P 1 NQI P 1 NQI P 1 NQI P 1 NQI P 1 NQI P 1 NQI 3

NQI 3

NQI 3

NQI 3

NQI P 1 NQI P 1 NQI P 1 NQI P 1 NQI P 1 NQI 3

NQI P 1 NQI 3

NQI 3

NQI 3

NQI P 1 NQI 3

TWDO 3

NQI 3

TWDO 3

TWDO

%TW LOCATION 012

+4.98 LTS

+35.53 009

+0.57 014

+11.88 013

+2.53 010

+0.63 010

+0.38 010

+0.00 013

+1.24 015

+17.76 006

+0.49 010

+0.59 006

+0.58 010

-0.65 010

+0.72 010

+0.70 010

-0.68 010

+0.70 006

+0.66 011

-0.29 011

+5.87 010

+17.90 013

+4.12 013

+3.62 012

-0.72 006

+0.58 013

-0.74 012

-0.74 013

-0.81 014

+24.69 012

+0.64 015

+23.04 011

+7.64 013

+3.37 014

+0.55 20 012

+8.55 013

+5.94 24 013

+4.09 26 012

+4.45 EXT UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE EXT LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTIL 1 UTIL 2 CAL #

124 67 66 66 66 66 50 50 49 67 67 66 66 67 67 66 66 66 66 49 49 49 49 50 67 66 67 67 66 49 49 49 49 50 49 50 50 50 50 LEG OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET PROBE 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL Total Tubes

3287 Total Records: 4164

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:26:27 Component: S/G B Page 1 of 30 ATTACHMENT #2 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW TUBE VOLTS 1

1 0.56 1

4 1.16 1

5 0.51 1

13 11.03 1

14 12.17 9.36 2

8 0.48 2

10 0.54 2

12 0.30 2

20 10.56 2

25 18.91 3

3 12.31 3.43 1.95 3

4 12.67 7.83 3

8 6.30 1.41 2.68 3

9 10.00 13.23 2.10 3

11 0.86 3

15 1.27 3

22 0.36 3

28 0.49 3

29 20.66 1.82 3

30 8.44 1.16 4

2 0.36 4

3 14.83 27.89 4

6 0.61 4

8 1.19 4

9 7.29 4

10 11.03 2.30 4

20 0.43 4

35 0.82 4

39 17.64 9.03 4

40 8.38 20.07 5

1 6.09 13.31 5

2 10.29 5

5 0.42 5

6 13.24 0.24 22.56 5

7 20.36 6.16 5

9 7.19 5

23 0.58 5

31 0.49 5

35 0.32 5

39 0.51 5

41 8.81 5

42 0.47 7.65 18.89 6

5 1.07 0.68 6

6 1.52 6

7 9.38 6

9 6.78 6

10 0.63 6

11 13.13 6

15 0.71 6

19 0.35 6

20 0.42 6

41 0.28 6

45 0.51 6

50 6.51 DEG 113 83 57 16 201 194 97 94 124 19 19 16 123 109 185 185 177 111 122 199 182 53 105 87 84 85 18 76 20 48 74 182 181 84 111 185 178 37 84 56 186 187 190 16 169 5

7 111 180 88 179 180 182 186 123 73 95 66 193 116 189 18 118 131 122 185 176 120 185 91 99 62 95 104 31 CHN P 1 P 1 P 1 P I P 1 P 1 3

3 3

P 1 P 1 P 1 P 1 P 1 3

3 P 1 P 1 P 1 P 1 P 1 P 1 3

P 1 3

P 1 P 1 6

P 1 6

P 1 3

3 3

3 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 3

3 P 1 3

3 3

P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 3

3 P 1 P 1 3

P 1 3

P1 P 1 P 1 P 1 P 1 IND NQI NQI NQI BLG BLG BLG NQI NQI NQI BLG BLG BLG NQI NQI DNT DNT DNT NQI NQI DNT DNT NQI NQI TWD NQI NQI BLG ADI BLG ADI NQI DNT DNT NQI NQI DNT DNT DWI NQI NQI DNT DNT DNT BLG DNT BLG BLG NQI DNT NQI DNT DNT DNT DNT NQI NQI NQI NQI DNT NQI DNT BLG NQI NQI NQI DNT DNT NQI DNT NQI NQI NQI NQI NQI BLG

%TW LOCATION EXT EXT 010

-0.22 UTE LTE 015

-0.43 UTE LTE 010

-0.16 UTE LTE UTS

-0.22 UTE LTE UTS

+0.05 UTE LTE 015

+0.67 UTE LTE 005

+20.01 UTE LTE 009

+12.96 UTE LTE 014

+1.06 UTE LTE UTS

-0.22 UTE LTE UTS

-0.16 UTE LTE UTS

-0.17 UTE LTE 015

+0.78 UTE LTE 015

-0.82 UTE LTE LTE

+14.40 UTE LTE LTE

+14.05 UTE LTE 010

-0.13 UTE LTE 015

-0.82 UTE LTE 015

+0.74 UTE LTE UTS

+0.05 UTE LTE 010

+0.00 UTE LTE 015

-0.86 UTE LTE 009

+37.64 UTE LTE 3

012

+1.13 UTE LTE 015

+18.60 UTE LTE 013

+0.57 UTE LTE UTS

-0.11 UTE LTE 015

+32.58 UTE LTE UTS

-0.15 UTE LTE 015

+32.38 UTE LTE 011

-0.75 UTE LTE UTS

+12.93 UTE LTE LTE

+10.93 UTE LTE 010

+25.00 TO+34.50 UTE LTE 009

+36.86 UTE LTE 010

-0.34 UTE LTE 010

-0.16 UTE LTE 010

-1.11 UTE LTE 009

-0.53 UTE LTE 010

+0.69 UTE LTE UTS

-0.02 UTE LTE 015

+0.67 UTE LTE 015

+0.87 UTE LTE UTS

-0.22 UTE LTE 015

+0.69 UTE LTE UTS

-0.20 UTE LTE UTS

-0.17 UTE LTE 004

+31.96 UTE LTE UTS

+13.00 UTE LTE 014

-0.24 UTE LTE LTE

+11.04 UTE LTE LTE

+10.91 UTE LTE UTS

+12.95 UTE LTE 010

+0.42 UTE LTE 009

+0.48 UTE LTE 008

+0.67 UTE LTE 009

+0.51 UTE LTE 008

+0.61 UTE LTE UTS

+0.00 UTE LTE 010

+0.53 UTE LTE 015

+0.73 UTE LTE UTS

-0.20 UTE LTE 009

+37.68 UTE LTE 010

-1.90 UTE LTE 009

+37.33 UTE LTE 010

-0.14 UTE LTE 010

+0.35 UTE LTE 014

+1.17 UTE LTE 010

-0.07 UTE LTE 009

+37.73 UTE LTE 008

-0.72 UTE LTE 010

-0.25 UTE LTE 008

-0.52 UTE LTE 011

-0.78 UTE LTE UTS

-0.18 UTE LTE UTIL 1 UTIL 2 CAL 58 58 57 62 61 61 57 57 58 61 61 58 58 58 57 57 58 58 58 57 57 57 57 57 62 62 61 61 62 62 57 57 57 57 58 57 58 58 57 61 62 62 61 61 58 58 58 57 58 58 58 57 57 57 57 62 62 62 62 61 61 61 58 58 57 57 58 57 57 58 58 57 62 62 61

  1. LEG OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET PROBE 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 5lOUL 51OUL 51OUL 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:26:27 Component: S/G B Page 2 of 30 ATTACHMENT #2 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW TUBE 7

5 7

8 7

10 7

13 7

14 7

16 7

17 7

19 7

44 7

45 7

46 7

51 7

53 8

1 8

5 8

10 8

13 8

21 8

34 8

42 8

47 8

48 9

5 9

23 9

24 9

56 9

57 9

61 10 2

10 7

10 9

10 13 10 14 10 25 10 51 10 59 10 63 10 65 11 10 11 11 11 19 11 20 11 21 11 64 11 65 11 67 VOLTS DEG 0.34 81 0.36 100 0.46 63 7.41 181 0.54 106 0.44 100 1.11 66 7.42 173 1.04 37 0.64 54 0.18 70 0.47 82 0.59 88 0.61 95 0.28 80 19.04 13 11.27 7

0.53 95 0.37 82 0.56 87 0.30 82 0.50 66 0.29 68 0.39 90 0.48 91 0.53 90 0.34 106 0.72 120 0.47 104 0.71 99 0.52 71 0.55 61 9.16 181 0.42 92 0.45 112 1.08 105 0.36 100 0.34 89 0.54 109 0.71 81 0.74 91 16.12 186 0.59 100 45.20 187 1.82 116 0.46 74 0.19 92 0.39 99 0.67 99 0.48 95 0.60 118 0.45 94 0.67 100 0.54 103 10.54 186 0.63 110 64.97 185 0.84 113 51.73 185 0.38 103 6.48 194 0.58 121 0.63 131 0.22 80 0.39 86 7.63 182 1.04 111 0.65 117 0.55 71 0.45 114 9.18 181 16.53 182 21.39 185 23.43 182 0.47 82 CHI 3

3 P

P 3

3 P

P P

P P

P P

P 3

P P

P P

P P

3 3

P P

P 3

3 P

P P

3 P

P P

P 3

3 P

P 3

P 3

P 3

3 3

3 P

3 3

p 3

3 p

3 P

3 P

3 P

3 P

P P

3 P

P 3

P 3

3 p

3 P

N IND NQI NQI 1 NQI 1 DNT NQI NQI 1 NQI 1 DNT 1 NQI 1 NQI 1 NQI 1 NQI 1 NQI 1 NQI NQI 1 BLG 1 BLG 1 NQI 1 TWD 1 NQI 1 NQI NQI NQI 1 NQI 1 NQI 1 NQI NQI NQI 1 NQI 1 NQI 1 NQI NQI 1 DNT 1 NQI 1 NQI 1 NQI NQI NQI 1 NQI 1 NQI NQI 1 DNT NQI 1 DNT NQI NQI NQI NQI 1 NQI NQI NQI 1 NQI NQI NQI 1 DNT NQI 1 DNT NQI 1 DNT NQI 1 DNT NQI 1 NQI 1 NQI 1 NQI DNT 1 NQI 1 NQI NQI 1 NQI DNT DNT 1 DNT DNT 1 NQI

%TW LOCATION EXT EXT UTIL 012

+28.91 UTE LTE 010

+5.40 UTE LTE 014

-0.11 UTE LTE 010

+0.56 UTE LTE 010

+4.77 UTE LTE 010

+4.13 UTE LTE 008

-0.49 UTE LTE 010

+0.22 UTE LTE 009

-0.09 UTE LTE 009

+0.52 UTE LTE 010

-0.20 UTE LTE 011

-0.81 UTE LTE 011

-0.73 UTE LTE 011

-0.81 UTE LTE LTS

+35.69 UTE LTE UTS

-0.09 UTE LTE UTS

-0.15 UTE LTE 014

+0.80 UTE LTE 23 014

+1.15 UTE LTE 010

-0.78 UTE LTE 014

+0.11 UTE LTE 006

+15.31 UTE LTE 013

+27.90 UTE LTE 007

+0.76 UTE LTE 008

+0.62 UTE LTE 008

+0.63 UTE LTE LTS

+30.25 UTE LTE LTS

+21.86 UTE LTE 009

-0.73 UTE LTE 010

+0.41 UTE LTE 009

+0.40 UTE LTE 002

+23.55 UTE LTE 015

-0.55 UTE LTE 011

-0.78 UTE LTE 009

+0.39 UTE LTE 009

-0.71 UTE LTE 015

+10.20 UTE LTE 011

+15.40 UTE LTE 009

+0.55 UTE LTE 011

-0.73 UTE LTE 009

+24.83 UTE LTE 015

-0.58 UTE LTE 015

+1.55 UTE LTE 015

+0.00 UTE LTE 014

+3.41 UTE LTE 015

+30.96 UTE LTE 015

+30.43 UTE LTE 015

+12.04 UTE LTE 009

-0.76 UTE LTE 014

+31.06 UTE LTE 014

+23.53 UTE LTE 009

+0.41 UTE LTE 008

+5.97 UTE LTE 008

+10.17 UTE LTE 010

-0.46 UTE LTE 010

-1.26 UTE LTE 015

-0.52 UTE LTE 014

+3.25 UTE LTE 015

-0.58 UTE LTE 014

+1.30 UTE LTE UTS

+0.00 UTE LTE 009

+38.52 UTE LTE 007

-0.84 UTE LTE 012

+0.22 UTE LTE 009

+0.45 UTE LTE 004

+14.46 UTE LTE 011

-0.81 UTE LTE 009

-0.59 UTE LTE 009

+23.51 TO+30.49 UTE LTE 010

-1.14 UTE LTE LTE

+8.73 UTE LTE LTE

+9.46 UTE LTE 015

-0.64 UTE LTE LTE

+8.86 UTE LTE 009

-0.60 UTE LTE 1 UTIL 2 CAL #

58 57 57 57 57 57 57 58 58 57 57 62 61 62 61 62 58 57 57 58 57 57 62 62 61 62 58 58 57 58 62 61 61 57 57 57 57 58 57 61 61 61 61 61 61 57 57 57 58 58 58 57 57 58 62 61 62 62 61 58 57 57 57 57 57 57 58 62 62 62 62 62 61 61 61 LEG OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET PROBE 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL SOUL S5OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 11 12 12 12 12 12 12 12 12 12 12 12 68 1

2 14 20 28 33 58 63 65 67 68

Framatome ANP Inc.

12/05/01 14:26:27 Customer Name: Oconee Unit 3 Component: S/G B Page 3 of 30 ATTACHMENT #2 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 12 70 41.83 183 P 1 DNT 015

-0.56 UTE LTE 62 OUTLET 51OUL 12 71 47.64 185 P 1 DNT 015

-0.62 UTE LTE 61 OUTLET 51OUL 0.80 109 3 NQI 011

+12.36 UTE LTE 61 OUTLET 51OUL 0.67 118 3 NQI 012

+1.02 UTE LTE 61 OUTLET 51OUL 13 4

0.46 87 3

NQI 009

+38.08 UTE LTE 58 OUTLET 51OUL 13 5

0.71 105 P 1 NQI 010

-0.64 UTE LTE 57 OUTLET 51OUL 13 6

0.50 81 3

NQI 009

+11.33 TO+21.51 UTE LTE 58 OUTLET 51OUL 13 18 0.95 154 P 1 NQI 007

-0.81 UTE LTE 58 OUTLET 51OUL 13 19 1.12 128 P 1 NQI 007

-0.82 UTE LTE 57 OUTLET 51OUL 13 20 1.01 151 P 1 NQI 007

-0.87 UTE LTE 58 OUTLET 51OUL 13 35 0.68 84 P 1 NQI 011

-0.75 UTE LTE 57 OUTLET 51OUL 13 38 0.23 110 3 NQI 001

+19.22 UTE LTE 62 OUTLET 51OUL 13 65 0.68 110 3 NQI 009

+21.40 TO+31.70 UTE LTE 62 OUTLET 51OUL 13 68 16.75 180 3 DNT LTE

+9.30 UTE LTE 61 OUTLET 51OUL 11.30 184 3 DNT LTE

+8.43 UTE LTE 61 OUTLET 51OUL 13 70 6.96 183 P 1 DNT 015

-0.73 UTE LTE 61 OUTLET 51OUL 19.17 181 3 DNT LTE

+9.21 UTE LTE 61 OUTLET 51OUL 13 71 45.85 185 P 1 DNT 015

-0.63 UTE LTE 62 OUTLET 51OUL 0.89 112 3 NQI 009

+38.41 UTE LTE 62 OUTLET 51OUL 13 72 34.27 184 P 1 DNT 015

-0.67 UTE LTE 61 OUTLET 51OUL 13 73 54.34 184 P 1 DNT 015

-0.54 UTE LTE 62 OUTLET 51OUL 13 74 50.48 186 P 1 DNT 015

-0.47 UTE LTE 61 OUTLET 51OUL 0.73 82 P 1 NQI 010

+0.24 UTE LTE 61 OUTLET 51OUL 14 55 0.65 81 P 1 NQI 011

-0.75 UTE LTE 61 OUTLET 51OUL 14 62 7.42 181 3 DNT LTS

+32.55 UTE LTE 61 OUTLET 51OUL 14 69 21.49 180 3 DNT LTE

+8.86 UTE LTE 61 OUTLET 51OUL 14 70 21.66 184 3 DNT LTE

+9.19 UTE LTE 62 OUTLET 51OUL 9.51 185 P 1 DNT 010

-0.33 UTE LTE 62 OUTLET 51OUL 14 72 12.93 187 P 1 DNT 015

-0.69 UTE LTE 62 OUTLET 51OUL 1.26 113 3 TWD 10 009

+38.50 UTE LTE 62 OUTLET 51OUL 14 73 41.16 187 P 1 DNT 015

-0.58 UTE LTE 61 OUTLET 51OUL 14 74 27.89 185 P 1 DNT 015

-0.63 UTE LTE 62 OUTLET 51OUL 14 75 24.16 185 P 1 DNT 015

-0.51 UTE LTE 61 OUTLET 51OUL 0.49 63 P 1 NQI 010

-0.05 UTE LTE 61 OUTLET 51OUL 1.85 105 3 NQI 014

+30.96 UTE LTE 61 OUTLET 51OUL 15 10 0.28 77 3

NQI 001

+25.45 UTE LTE 57 OUTLET 51OUL 15 18 0.36 78 3

NQI 012

+9.51 UTE LTE 57 OUTLET 51OUL 15 39 9.08 180 3 DNT 006

+17.01 UTE LTE 57 OUTLET 51OUL 6.00 184 3 DNT 009

+5.45 UTE LTE 57 OUTLET 51OUL 15 64 0.56 79 P 1 NQI 009

+0.61 UTE LTE 61 OUTLET 51OUL 15 67 0.67 103 3 NQI 009

+10.15 TO+27.55 UTE LTE 62 OUTLET 51OUL 15 68 0.86 80 3

NQI 009

+23.40 UTE LTE 61 OUTLET 51OUL 15 69 0.59 94 3

NQI 009

+21.75 TO+34.16 UTE LTE 62 OUTLET 51OUL 15 71 0.40 97 3

NQI 009

+38.67 UTE LTE 62 OUTLET 51OUL 15 74 0.65 87 3

NQI 009

+37.46 UTE LTE 61 OUTLET 51OUL 15 76 37.59 186 P 1 DNT 015

-0.60 UTE LTE 61 OUTLET 51OUL 15 77 34.68 184 P 1 DNT 015

-0.56 UTE LTE 62 OUTLET 51OUL 15 78 38.65 184 P 1 DNT 015

-0.55 UTE LTE 61 OUTLET 51OUL 0.54 76 P 1 NQI 010

+0.31 UTE LTE 61 OUTLET 51OUL 16 1

10.17 190 P 1 DNT UTS

+0.02 UTE LTE 56 OUTLET 51OUL 7.95 174 P 1 DNT 015

+0.72 UTE LTE 56 OUTLET S5OUL 16 16 0.33 93 3

NQI 014

+21.77 UTE LTE 57 OUTLET 51OUL 16 21 0.38 82 3

NQI 012

+27.55 UTE LTE 58 OUTLET 51OUL 16 42 0.36 95 3

NQI 014

+23.92 UTE LTE 62 OUTLET 51OUL 16 66 0.33 100 3 NQI 010

+27.64 UTE LTE 62 OUTLET 51OUL 0.60 83 P 1 NQI 009

+0.68 UTE LTE 62 OUTLET 51OUL 16 72 0.79 101 3 NQI 009

+24.00 TO+32.72 UTE LTE 61 OUTLET 51OUL 16 78 32.27 184 P 1 DNT 015

-0.60 UTE LTE 61 OUTLET 51OUL 16 79 26.58 183 P 1 DNT 015

-0.65 UTE LTE 62 OUTLET 51OUL 16 80 34.36 184 P 1 DNT 015

-0.44 UTE LTE 61 OUTLET 51OUL 16 81 27.92 186 P 1 DNT 015

-0.51 UTE LTE 61 OUTLET 51OUL 2.67 119 3 NQI 014

+32.13 UTE LTE 61 OUTLET 51OUL 17 34 0.22 90 P 1 NQI 004

-0.83 UTE LTE 56 OUTLET 51OUL 17 53 0.71 96 P 1 NQI 011

-0.80 UTE LTE 62 OUTLET 51OUL 17 72 1.22 116 3 NQI 009

+20.24 TO+28.11 UTE LTE 61 OUTLET 51OUL 17 74 0.66 67 P 1 NQI 009

+0.63 UTE LTE 61 OUTLET 51OUL 2.05 107 3 NQI 009

+21.21 TO+31.22 UTE LTE 61 OUTLET 51OUL 17 75 1.02 120 P 1 NQI 008

-0.72 UTE LTE 62 OUTLET 51OUL 17 77 0.60 57 P 1 NQI 009

-0.67 UTE LTE 62 OUTLET 51OUL 0.71 37 P 1 NQI 009

+0.70 UTE LTE 62 OUTLET 51OUL 17 79 11.42 188 P 1 DNT 015

-0.78 UTE LTE 62 OUTLET 51OUL 17 80 8.34 179 P 1 DNT 015

-0.75 UTE LTE 61 OUTLET 51OUL 17 81 9.63 191 P 1 DNT 015

-0.65 UTE LTE 62 OUTLET 51OUL 17 82 12.66 182 P 1 DNT 015

-0.51 UTE LTE 61 OUTLET 51OUL 18 2

1.20 104 P 1 NQI 014

+0.60 UTE LTE 51 OUTLET 51OUL

Framatome ANP Inc.

12/05/01 14:26:27 Customer Name: Oconee Unit 3 Component: S/G B Page 4 of 30 ATTACHMENT #2 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL 4 LEG PROBE 18 4

0.69 71 3

NQI 009

+16.72 UTE LTE 52 OUTLET 51OUL 18 5

0.31 63 P 1 NQI 015

-0.40 UTE LTE 51 OUTLET 51OUL 18 16 0.47 73 3

NQI 004

+2.73 UTE LTE 52 OUTLET 51OUL 18 56 0.37 115 3 TWD 6 003

+2.47 UTE LTE 62 OUTLET 51OUL 18 66 0.47 123 3 NQI 013

+24.13 UTE LTE 67 OUTLET 51OUL 18 71 0.66 140 F 1 NQI 008

+0.58 UTE LTE 66 OUTLET 51OUL 18 79 0.54 106 P 1 NQI 010

+0.57 UTE LTE 67 OUTLET 51OUL 0.47 111 P 1 NQI 010

+0.11 UTE LTE 67 OUTLET 51OUL 0.98 106 3 NQI 009

+23.52 TO+28.14 UTE LTE 67 OUTLET 51OUL 18 81 0.56 93 P 1 NQI 009

+0.55 UTE LTE 67 OUTLET 51OUL 0.99 126 P 1 NQI 009

-0.72 UTE LTE 67 OUTLET 51OUL 19 5

0.59 113 P 1 NQI 009

+0.51 UTE LTE 52 OUTLET 51OUL 19 11 0.64 131 P 1 NQI 007

-0.82 UTE LTE 52 OUTLET 51OUL 19 16 0.40 76 P 1 NQI UTS

+13.18 UTE LTE 51 OUTLET 51OUL 19 17 0.31 66 3

NQI 011

+6.87 UTE LTE 52 OUTLET 51OUL 19 19 0.52 86 P 1 NQI 011

-0.83 UTE LTE 52 OUTLET 51OUL 19 55 0.82 88 P 1 NQI 011

-0.78 UTE LTE 67 OUTLET 51OUL 19 67 0.42 99 P 1 NQI 014

+0.48 UTE LTE 67 OUTLET 51OUL 19 71 0.73 87 P 1 NQI 013

+0.80 UTE LTE 67 OUTLET 51OUL 0.21 95 3

NQI 001

+14.48 UTE LTE 67 OUTLET 51OUL 19 78 0.77 99 P 1 NQI 008

-0.70 UTE LTE 66 OUTLET 51OUL 19 79 0.63 109 3 NQI 009

+21.09 TO+26.21 UTE LTE 67 OUTLET 51OUL 0.72 127 P 1 NQI 008

-0.63 UTE LTE 67 OUTLET 51OUL 19 80 0.82 102 3 NQI 009

+23.85 UTE LTE 66 OUTLET 51OUL 19 82 0.67 60 P 1 NQI 009

+0.70 UTE LTE 66 OUTLET 51OUL 1.19 98 P 1 NQI 010

+0.47 UTE LTE 66 OUTLET 51OUL 19 86 4.44 48 P 1 NQI 015

+0.78 UTE LTE 66 OUTLET 51OUL 20 16 0.99 128 3 NQI 010

+28.73 UTE LTE 52 OUTLET 51OUL 20 19 0.55 73 3

NQI 014

+16.34 UTE LTE 51 OUTLET SlOUL 20 30 0.34 84 3

NQI 011

+34.97 UTE LTE 52 OUTLET 51OUL 20 73 0.62 60 P 1 NQI 008

+0.57 UTE LTE 67 OUTLET 51OUL 20 75 0.50 79 P 1 NQI 008

+0.46 UTE LTE 67 OUTLET 51OUL 20 77 0.64 105 P 1 NQI 008

-0.65 UTE LTE 67 OUTLET 51OUL 20 78 1.21 118 P 1 NQI 008

-0.60 UTE LTE 66 OUTLET 51OUL 0.72 103 P 1 NQI 009

+0.63 UTE LTE 66 OUTLET 51OUL 20 79 0.63 45 P 1 NQI 008

+0.71 UTE LTE 67 OUTLET 51OUL 20 80 0.49 109 3 NQI 012

+1.19 UTE LTE 66 OUTLET 51OUL 20 81 0.67 90 P 1 NQI 009

+0.66 UTE LTE 67 OUTLET 51OUL 20 83 0.54 82 3

NQI 014

+31.06 UTE LTE 67 OUTLET 51OUL 21 2

0.21 92 3

NQI 014

+13.59 UTE LTE 52 OUTLET 51OUL 21 6

0.41 97 3

NQI 006

+4.55 UTE LTE 52 OUTLET 51OUL 21 8

0.27 100 3 NQI 012

+31.20 UTE LTE 52 OUTLET 51OUL 21 15 1.10 117 P 1 NQI 007

-0.80 UTE LTE 52 OUTLET 51OUL 21 19 0.21 103 3 TWD 22 LTS

+18.42 UTE LTE 52 OUTLET 51OUL 21 38 0.32 97 3

NQI 014

+10.75 UTE LTE 51 OUTLET 51OUL 21 72 1.49 61 P 1 NQI 011

-0.78 UTE LTE 66 OUTLET 51OUL 21 77 0.56 93 P 1 NQI 011

-0.78 UTE LTE 67 OUTLET 51OUL 21 78 0.84 46 P 1 NQI 009

+0.65 UTE LTE 66 OUTLET 51OUL 21 81 0.27 56 P 1 NQI 012

+0.41 UTE LTE 67 OUTLET 51OUL 21 84 1.03 137 P 1 NQI 008

-0.69 UTE LTE 67 OUTLET 51OUL 21 85 0.60 91 P 1 NQI 009

+0.59 UTE LTE 66 OUTLET 51OUL 21 88 0.59 94 3

NQI 014

+33.23 UTE LTE 67 OUTLET 51OUL 22 20 0.31 85 3

NQI 008

+26.38 UTE LTE 51 OUTLET 51OUL 0.31 72 3

NQI 008

+1.62 UTE LTE 51 OUTLET 51OUL 22 70 1.05 61 P 1 NQI 011

-0.78 UTE LTE 66 OUTLET 51OUL 22 74 0.32 97 3

NQI LTS

+35.48 UTE LTE 66 OUTLET 51OUL 0.82 114 3 NQI LTS

+24.15 UTE LTE 66 OUTLET 51OUL 3.44 112 3 NQI LTS

+23.40 UTE LTE 66 OUTLET 51OUL 22 89 0.66 62 P 1 NQI 009

+0.75 UTE LTE 67 OUTLET 51OUL 22 90 0.94 92 P 1 NQI 009

-0.77 UTE LTE 66 OUTLET 51OUL 0.85 61 P 1 NQI 009

+0.63 UTE LTE 66 OUTLET 51OUL 22 93 10.07 189 P 1 DNT 015

-0.67 UTE LTE 67 OUTLET 51OUL 23 19 0.29 92 3

NQI 003

+24.63 UTE LTE 51 OUTLET 51OUL 23 35 0.32 51 3

NQI 015

+37.18 UTE LTE 51 OUTLET 51OUL 23 48 0.26 107 3 NQI 011

+25.85 UTE LTE 71 OUTLET 51OUL 23 80 0.33 73 P 1 NQI LTE

+18.85 UTE LTE 67 OUTLET 51OUL 23 93 1.07 110 3 NQI 006

+1.54 UTE LTE 66 OUTLET 51OUL 24 7

0.33 92 3

NQI 011

+24.99 UTE LTE 51 OUTLET 51OUL 24 18 0.36 101 3 NQI 006

+23.09 UTE LTE 52 OUTLET 51OUL 0.38 80 3

NQI 006

+22.68 UTE LTE 52 OUTLET 51OUL 24 19 0.48 74 P 1 NQI 007

-0.44 UTE LTE 51 OUTLET 51OUL 24 37 0.78 87 P 1 TWD 3 014

+0.91 UTE LTE 51 OUTLET 51OUL 24 45 0.27 102 3 NQI 009

+18.77 UTE LTE 51 OUTLET 51OUL 24 74 0.39 84 3

NQI 014

+21.85 UTE LTE 72 OUTLET 51OUL 24 80 0.24 99 3

NQI 013

-1.74 UTE LTE 72 OUTLET 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:26:27 Component: S/G B Page 5 of 30 ATTACHMENT #2 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW 24 25 25 25 25 25 25 26 26 26 26 26 26 26 26 26 27 27 27 27 27 27 27 27 27 28 28 28 28 28 29 29 29 29 29 29 29 29 29 29 29 30 30 30 30 30 30 30 30 31 31 31 31 31 31 31 31 31 32 32 TUBE VOLTS 87 0.91 3

0.53 4

0.56 24 0.39 0.26 0.26 0.21 0.26 69 0.60 87 0.33 96 0.45 3

0.39 5

0.42 15 0.43 0.31 17 0.20 0.19 22 11.62 56 0.59 67 0.30 87 0.45 0.47 98 0.59 1

8.43 7.39 28 0.43 41 0.21 47 0.40 78 0.46 81 0.70 90 14.55 91 0.44 100 0.76 1

5.68 5

0.22 43 0.52 64 12.71 10.00 98 0.38 2

13.11 0.61 5

0.51 8

0.36 39 0.13 49 0.19 67 0.31 72 10.79 76 0.51 82 0.94 83 0.90 102 1.01 0.81 0.73 1

0.50 4

0.44 0.41 6

0.67 21 0.60 38 0.53 51 0.33 103 0.51 104 0.55 1

10.95 6

0.57 0.38 8

0.47 26 0.32 44 0.81 52 0.27 76 0.24 0.96 85 0.38 104 0.34 4

0.51 5

0.81 DEG CHN 85 P 1 128 P 1 70 P 1 89 3

105 3 94 3

80 3

86 3

92 3

89 3

72 3

88 P 1 124 P 1 83 3

67 3

105 3 85 3

180 3 80 P 1 85 3

125 3 106 3 105 3 18 P 1 14 P 1 86 3

114 P 1 57 3

97 P 1 80 3

176 3 104 3 104 P 1 31 P 1 82 P 1 103 3 184 3 182 3 87 3

185 P 1 123 P 1 92 P 1 89 3

95 P 1 57 3

99 3

184 3 102 3 122 P 1 76 P 1 103 3 107 3 80 3

91 P 1 121 P 1 68 P 1 75 P 1 127 P 1 58 3

70 P 1 101 P 1 81 P 1 183 P 1 113 3 38 3

73 P 1 70 3

100 P 1 107 3 84 3

124 P 1 96 3

86 P 1 102 3 56 P 1 IND %TW LOCATION EXT NQI LTE

+3.78 UTE NQI 009

+0.64 UTE NQI 009

+0.60 UTE NQI 012

+3.28 UTE NQI 011

+34.85 UTE NQI 011

+33.80 UTE NQI 011

+12.12 UTE NQI 008

+15.43 UTE NQI 004

+8.95 UTE NQI 013

+4.46 UTE NQI 012

+9.03 UTE NQI 009

-0.78 UTE NQI 008

-0.80 UTE NQI 001

+1.72 UTE NQI 001

+1.85 UTE NQI 011

+18.79 UTE NQI 009

+8.30 UTE DNT 010

+8.21 UTE NQI 013

+0.74 UTE NQI 012

+24.10 UTE NQI LTS

+19.07 UTE NQI 013

+1.15 UTE TWD 15 012

+1.47 UTE DNT UTS

-0.22 UTE DNT 015

+0.97 UTE NQI 005

+29.92 UTE NQI 013

+0.04 UTE NQI 010

+9.90 UTE NQI 004

-0.77 UTE NQI 015

+29.71 UTE DNT 011

+13.55 UTE NQI 013

+8.22 UTE NQI 010

+0.78 UTE NQI UTS

-0.28 UTE NQI 008

-0.59 UTE NQI 005

+10.19 UTE DNT 001

+32.25 UTE DNT 001

+25.24 UTE NQI 004

+27.03 UTE DNT 010

+0.35 UTE NQI 011

+0.47 UTE NQI 009

+0.62 UTE NQI 003

+14.75 UTE NQI 014

-0.17 UTE NQI 012

+19.75 UTE NQI 008

+22.85 UTE DNT LTS

+40.40 UTE NQI 013

+6.47 UTE NQI 011

-0.78 UTE NQI 011

-0.73 UTE NQI 008

+6.29 UTE NQI 008

+6.90 UTE NQI 008

+8.84 UTE NQI 015

-0.39 UTE NQI 008

+0.58 UTE NQI 010

-0.54 UTE NQI 008

-0.54 UTE NQI 007

-0.78 UTE NQI 003

+5.03 UTE NQI 004

-1.11 UTE NQI 008

+0.13 UTE NQI 008

-0.51 UTE DNT 010

+0.28 UTE NQI 010

+14.41 UTE NQI 009

+38.07 UTE NQI 009

+0.60 UTE NQI 008

+37.55 UTE NQI LTE

+5.01 UTE NQI 013

+20.88 UTE NQI 011

+2.07 UTE NQI 011

-0.81 UTE TWD 33 014

+11.44 UTE TWD 13 014

+1.20 UTE NQI 005

+1.88 UTE NQI 009

+0.63 UTE EXT LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTIL 1 UTIL 2 CAL #

71 51 52 51 51 51 51 51 71 71 72 48 48 48 48 48 48 47 72 71 72 72 71 48 48 47 48 48 71 72 72 71 72 48 48 48 71 71 72 47 47 48 47 48 48 71 72 72 72 71 72 72 72 48 47 47 47 48 47 48 75 75 48 48 48 48 48 48 48 76 76 75 75 47 47 LEG PROBE OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:26:27 Component: S/G B Page 6 of 30 ATTACHMENT #2 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW 32 32 32 32 32 32 32 32 33 33 33 33 33 33 33 33 33 34 34 34 34 34 34 34 34 34 35 35 35 35 35 36 36 36 36 36 36 36 36 36 37 37 37 37 37 37 37 38 38 38 38 38 38 38 38 38 38 38 39 TUBE 15 53 58 60 61 62 86 106 1

2 4

6 30 39 81 106 107 3

6 20 22 23 57 77 91 107 2

6 73 77 108 5

6 8

9 83 85 109 110 113 20 25 32 59 79 107 114 5

6 8

19 24 34 46 61 100 103 115 6

VOLTS 0.13 0.49 0.30 0.14 0.33

0. 19 0.43 0.26 11.10 9.26 0.31 0.43 0.43 0.83 0.77 0.44 0.90 0.43 0.53 1.22 0.64 0.36 0.81 1.27 0.71 0.59 1.20 0.60 0.66 0.43 6.38 0.52 0.61 8.56 0.46 0.47 0.71 0.67 8.04 0.78 26.86 7.26 16.08
1. 10 0.51 0.30 0.66 0.27 0.53 0.46 0.50 0.33 0.21 0.32 0.24 0.25 6.04 0.27 0.41 0.44 0.53 0.79 0.57 24.11 8.07 0.41 0.47 0.34 0.43 0.25 0.28 0.48 0.28 0.52 0.28 DEG CHN IND 97 P 1 NQI 83 P 1 NQI 93 3

NQI 67 P 1 NQI 93 3

NQI 115 P 1 NQI 103 3 TWD 78 P 1 NQI 15 P 1 BLG 175 P 1 DNT 90 3

NQI 97 P 1 NQI 104 3 NQI 114 P 1 NQI 86 P 1 NQI 112 3 NQI 75 P 1 NQI 76 3

NQI 86 3

NQI 152 P 1 NQI 134 P 1 NQI 123 3 NQI 112 P 1 NQI 91 6

ADI 60 P 1 NQI 43 P 1 NQI 77 P 1 NQI 88 3

NQI 118 P 1 NQI 77 3

NQI 181 3 DNT 110 3 TWD 104 P 1 NQI 183 P 1 DNT 54 P 1 NQI 78 P 1 NQI 116 3 NQI 16 P 1 NQI 185 P 1 DNT 119 6 ADI 182 3 DNT 181 3 DNT 180 3 DNT 83 P 1 NQI 125 P 1 NQI 97 3

NQI 81 3

NQI 79 P 1 NQI 89 P 1 NQI 74 P 1 NQI 104 3 NQI 81 3

NQI 93 3

NQI 112 3 NQI 94 3

NQI 129 3 NQI 184 3 DNT 107 3 NQI 108 3 TWD 66 P 1 NQI 109 3 NQI 60 P 1 NQI 33 P 1 NQI 182 3 DNT 180 3 DNT 122 P 1 NQI 70 3

NQI 92 3

NQI 92 P 1 NQI 75 3

NQI 92 3

NQI 56 3

NQI 88 3

1 NQI 100 P 1 NQI 99 P 1 NQI

%TW LOCATION 007

-0.90 LTE

+4.62 010

+33.59 013

-0.09 007

+6.74 013

+0.00 22 LTS

+41.80 008

-0.68 UTS

+0.00 015

+0.78 002

+25.57 014

+0.24 009

+37.93 010

-0.59 008

-0.39 009

+14.52 013

-0.18 011

+31.88 011

+28.22 011

-0.85 009

+0.49 005

+1.15 008

-0.55 010

+2.65 008

-0.51 009

+0.64 012

+0.89 011

+4.74 007

-0.74 008

+16.13 LTS

+16.44 5

014

+1.37 008

+0.59 010

-0.38 008

-0.52 013

-0.18 015

+42.83 008

+0.46 010

-0.07 010

+1.33 TO+6.80 LTE

+15.99 UTS

+12.14 LTE

+16.31 008

-0.62 008

-0.69 014

+11.56 006

+15.93 009

+0.58 014

+0.98 008

+0.69 LTS

+13.08 010

+30.29 008

+15.03 010

+1.55 008

+27.74 008

+24.97 006

+2.74 015

+32.89 14 001

+6.24 008

-0.18 009

+32.51 TO+38.91 009

+0.62 008

+0.74 LTE

+15.83 UTS

+12.20 008

-0.65 011

+5.14 010

+30.55 013

+0.50 008

+10.59 015

+25.21 012

+33.26 013

+9.82 008

-0.18 010

+0.60 EXT UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE EXT LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTIL 1 UTIL 2 CAL 48 48 84 84 83 84 76 76 48 48 48 48 48 48 48 48 47 48 76 76 76 75 75 48 47 47 47 47 48 83 75 76 76 41 42 75 75 76 42 42 42 41 41 41 41 75 75 75 76 76 41 41 42 42 42 42 83 75 75 76 42 42 42 41 41 42 41 42 42 42 83 76 75 76 41 4 LEG OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET PROBE 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 5lOUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:26:27 Component: S/G B Page 7 of 30 ATTACHMENT #2 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW TUBE VOLTS 39 7

1.12 0.55 0.27 0.27 39 10 0.43 39 17 0.43 39 56 8.02 39 79 0.70 40 2

0.67 40 4

1.02 40 5

0.49 0.42 0.35 40 6

0.52 0.31 40 8

0.78 40 80 2.75 40 110 7.68 6.67 6.63 8.54 40 117 0.30 41 4

0.85 41 5

0.60 0.57 41 26 0.26 41 50 0.25 41 55 0.64 41 62 0.30 41 63 0.36 41 75 0.27 41 113 0.63 41 114 0.40 42 3

1.27 42 4

0.20 0.44 42 5

0.49 0.63 42 14 0.54 42 26 0.50 42 48 0.32 42 52 0.30 42 72 0.33 42 109 0.21 42 112 0.38 42 114 0.62 42 116 0.32 42 117 0.43 43 1

0.25 43 6

0.46 43 7

0.74 43 21 0.28 0.47 43 86 0.42 43 112 0.52 44 3

1.02 1.86 44 4

2.94 44 16 0.34 44 23 0.48 44 65 6.46 44 100 7.35 45 1

0.45 45 3

0.32 45 5

0.46 45 22 0.28 45 42 0.29 0.41 45 62 0.42 45 65 6.78 45 66 6.07 45 88 0.28 45 89 0.30 45 119 0.66 46 4

1.74 DEG 90 113 77 95 63 126 180 97 108 80 103 84 74 60 103 155 112 191 187 187 187 99 66 96 91 95 96 110 127 81 96 86 104 28 87 88 71 139 101 68 92 87 74 85 103 80 110 108 88 121 69 99 102 77 99 43 86 92 117 96 188 182 101 106 89 81 95 120 93 180 189 94 96 127 81 CHN IND 6

ADI 3

NQI 3

NQI P 1 NQI P 1 NQI 3

NQI 3

DNT 3

NQI P 1 NQI P 1 NQI 3

NQI P 1 NQI P 1 NQI P 1 NQI P 1 NQI P 1 NQI 3

NQI 3

DNT 3

DNT 3

DNT 3

DNT 3

NQI P 1 NQI P 1 NQI 3

NQI 3

NQI 3

NQI 3

TWDO 3

NQI 3

NQI 3

NQI P 1 NQI 3

NQI P 1 NQI P 1 NQI P 1 NQI P 1 NQI P 1 NQI 3

NQI P 1 NQI 3

NQI 3

NQI 3

NQI 3

NQI 3

NQI 3

NQI 3

NQI P 1 NQI 3

NQI P 1 NQI P 1 NQI 3

NQI 3

NQI P 1 NQI 3

NQI P 1 NQI P 1 NQI P 1 TWD 3

NQI 3

NQI P 1 DNT 3

DNT P 1 NQI 3

NQI P 1 NQI 3

NQI 3

NQI 3

NQI 3

NQI P 1 DNT P 1 DNT 3

NQI 3

NQI P 1 NQI P 1 NQI

%TW LOCATION 009

+21.49 TO+28.78 013

+22.20 010

+25.99 013

-0.20 008

+0.69 001

+4.03 008

+15.92 006

+11.24 010

+0.52 009

+0.69 010

+2.91 010

+0.13 010

+0.64 009

+0.18 010

+0.39 008

-0.69 015

+8.53 LTS

+13.21 LTE

+16.29 LTE

+2.78 LTE

+23.09 015

+26.53 012

-0.33 010

+0.46 009

+24.75 012

+34.18 009

+20.56 B

003

+22.83 015

+18.85 006

+13.50 009

+4.41 008

+0.62 008

+29.21 009

+0.73 010

+0.38 009

+0.69 009

+0.61 010

+0.56 005

+32.79 UTS

+18.36 005

+20.10 015

+19.14 006

+29.04 011

+22.54 002

+21.92 TO+29.50 011

+25.96 002

+21.91 008

+0.32 012

+19.96 008

+0.54 008

+0.64 010

+17.85 006

+27.86 010

+0.06 012

+18.17 009

+0.73 014

+0.77 36 014

+0.79 005

+25.72 014

+1.15 LTS

-0.09 001

+5.93 014

-0.81 010

+5.10 009

+0.67 001

+3.96 LTS

+42.42 LTS

+41.87 009

+18.12 LTS

-0.09 LTS

+0.00 007

+31.91 013

+13.30 008

-0.57 010

+0.65 EXT UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE EXT LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTIL 1 UTIL 2 CAL 4 42 42 42 42 41 42 41 79 42 42 41 41 41 42 42 42 83 84 84 84 84 84 12 13 13 12 12 13 83 83 84 83 84 20 21 21 20 20 36 13 13 13 83 87 88 88 88 88 21 20 21 21 21 88 88 20 20 21 21 21 87 87 21 21 21 20 21 21 91 92 107 92 91 107 20 LEG OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET PROBE 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:26:27 Component: S/G B Page 8 of 30 ATTACHMENT #2 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW TUBE 46 26 46 50 46 76 46 83 95 99 4

8 46 74 75 83 85 90 93 103 105 114 117 122 3

29 44 61 63 74 75 77 1

48 56 58 59 73 74 75 76 77 82 113 114 121 3

4 11 29 62 70 71 74 75 76 77 107 3

4 6

28 47 VOLTS 2.02 0.25 0.31 0.37 0.42

2. 92 0.48 2.27 0.33 0.51 1.23 1.38 0.35 0.38 6.14 0.27 0.41 0.27 0.30 0.41 0.25 0.47 0.30 0.26 0.31 0.55 0.25
1. 11 0.33 0.57 0.99 0.48 0.22 0.46 10.99 0.26 6.06 8.19 6.77
6. 69 0.40 0.40 6.22 6.30 0.18 7.09 8.91 0.27 6.08 0.32 1.22 2.35 0.32 0.38 0.77 0.39 0.34 0.33 0.28 0.44 0.37 0.36 7.39
7. 67 6.12 8.11 6.39 8.28 0.39
0. 67 0.36 0.49 6.35 6.40 0.32 DEG 35 107 96 85 124 189 40 187 84 104 56 68 76 97 181 93 105 99 80 101 90 92 88 57 107 61 87 40 128 110 107 72 106 91 181 57 191 180 179 180 93 69 189 174 73 187 176 97 181 82 50 105 100 107 76 108 96 99 86 81 67 113 185 184 189 181 191 180 74 90 69 80 187 186 92 CHN P 1 3

3 3

3 3

3 3

3 P I P 1 P 1 3

P 1 P1 3

3 3

3 3

3 3

3 3

3 P 1 3

P1 3

3 3

P1 3

P 1 3

P 1 P 1 P 1 P 1 P

3 3

P 1 P 1 P 1 P 1 P1 P1 21 3

P 1 3

3 3

P 1 3

3 3

3 3

3 P 1 P 1 P 1 P 1 P 1 P 1 P 1 3

P 1 3

3 3

3 3

IND NQI NQI NQI NQI DWI DNT DWI DNT NQI NQI NQI NQI NQI NQI DNT NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI DNT NQI DNT DNT DNT DNT TWD NQI DNT DNT NQI DNT DNT NQI DNT NQI NQI TWD NQI NQI NQI NQI TWD TWD NQI NQI NQI NQI DNT DNT DNT DNT DNT DNT NQI NQI NQI NQI DNT DNT NQI

%TW LOCATION EXT EXT 014

+0.74 UTE LTE 013

+7.26 UTE LTE 008

+22.48 UTE LTE 007

+30.13 UTE LTE 014

+15.37 UTE LTE 014

+15.22 UTE LTE 014

+3.64 UTE LTE 014

+3.64 UTE LTE LTS

+18.32 UTE LTE 014

-0.53 UTE LTE 011

-0.81 UTE LTE 010

+0.63 UTE LTE 014

+5.36 UTE LTE 014

+0.42 UTE LTE LTS

+0.00 UTE LTE 012

+31.92 UTE LTE 012

+8.61 UTE LTE 010

+4.28 UTE LTE 009

+30.72 UTE LTE 008

+26.79 UTE LTE 007

+23.51 UTE LTE 003

+22.13 UTE LTE 014

+22.59 UTE LTE 013

+24.75 UTE LTE 010

+13.42 UTE LTE 012

+0.39 UTE LTE 014

+2.04 UTE LTE UTS

+13.81 UTE LTE 015

+12.50 UTE LTE 010

+1.23 UTE LTE 015

+18.77 UTE LTE 009

+0.64 UTE LTE 008

+22.87 UTE LTE 014

+0.42 UTE LTE 008

+16.82 UTE LTE 014

+0.09 UTE LTE LTS

-0.26 UTE LTE LTS

-0.06 UTE LTE LTS

+0.00 UTE LTE 010

+0.00 UTE LTE 35 013

+25.05 UTE LTE 013

+31.96 UTE LTE LTS

+0.00 UTE LTE LTS

+0.00 UTE LTE 014

-0.37 UTE LTE LTS

+0.00 UTE LTE LTS

+0.00 UTE LTE 014

+0.24 UTE LTE LTS

-0.09 UTE LTE LTS

+18.91 UTE LTE 011

+0.77 UTE LTE 17 011

+1.51 UTE LTE 013

+1.56 UTE LTE 009

+16.15 TO+28.94 UTE LTE 009

+0.66 UTE LTE 009

+17.04 UTE LTE 31 011

+26.43 UTE LTE 26 008

+29.46 UTE LTE 011

+3.47 UTE LTE 008

+7.67 UTE LTE 013

+30.90 UTE LTE 013

+0.31 UTE LTE LTS

+0.00 UTE LTE LTS

+0.00 UTE LTE LTS

-0.07 UTE LTE LTS

+0.00 UTE LTE LTS

+0.00 UTE LTE LTS

-0.04 UTE LTE 014

+6.54 UTE LTE 009

+0.74 UTE LTE 009

+14.82 TO+27.08 UTE LTE 002

+2.59 UTE LTE 001

+5.50 UTE LTE LTE

+11.37 UTE LTE 013

+11.17 UTE LTE UTIL 1 UTIL 2

==

CAL #

20 21 21 92 91 91 91 91 91 91 91 20 20 21 92 91 91 91 91 91 91 91 91 92 91 91 91 92 91 92 92 20 20 20 36 122 93 94 94 36 18 18 33 36 107 107 108 93 94 93 93 93 93 26 26 19 26 26 26 26 19 33 95 96 95 96 95 96 96 19 26 26 126 126 19 LEG OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET PROBE 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 5lOUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:26:27 Component: S/G B Page 9 of 30 ATTACHMENT #2 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW 51 51 51 51 51 51 51 51 51 51 51 51 52 52 52 52 52 52 52 52 52 52 52 52 52 52 52 52 52 52 52 52 52 52 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 54 54 54 54 54 54 54 54 54 TUBE VOLTS 57 8.29 58 6.18 59 8.18 71 7.72 72 8.36 74 0.30 78 6.11 79 8.38 80 7.05 81 6.45 123 8.65 124 10.49 6.56 0.34 26 0.76 29 0.39 35 0.44 54 6.56 56 6.25 57 9.54 58 9.24 59 10.42 60 7.71 61 6.32 71 14.47 72 25.48 73 16.03 74 13.88 75 10.39 0.42 79 0.24 80 8.44 81 7.55 98 0.93 108 1.03 113 0.35 121 0.55 1

0.58 0.90 2

0.31 7

0.20 0.39 17 0.21 21 0.20 28 0.36 30 0.25 54 0.57 56 9.74 57 10.19 58 8.39 59 8.67 60 8.54 68 7.26 69 6.62 70 6.71 71 0.50 14.56 72 9.03 74 10.44 75 20.68 76 16.07 77 6.42 0.54 82 7.71 101 0.36 105 0.27 7

0.81 41 0.40 55 12.33 56 14.15 57 13.65 58 8.65 59 8.69 60 7.10 62 6.33 DEG 177 192 176 187 186 113 192 183 189 181 27 191 178 123 83 86 86 180 188 176 189 177 188 173 185 187 183 187 182 95 108 189 180 50 47 106 101 86 85 99 99 101 109 98 95 98 87 177 187 176 188 175 186 178 184 76 178 182 182 188 181 191 103 178 71 108 58 104 187 188 176 184 175 184 186 CHN P=1 P 1 P 1 P 1 P 1 3

P 1 P 1 P 1 P 1 P 1 P1 P 1 3

3 3

3 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P1 3

3 P1 P 1 P 1 P 1 3

P 1 P 1 3

3 P 1 3

3 3

3 3

3 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 21 3

P 1 P 1 3

P 1 3

P1 P 1 P 1 P 1 P 1 P 1 P 1 IND

=NT DNT DNT DNT DNT NQI DNT DNT DNT DNT BLG DNT DNT NQI NQI NQI NQI DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT NQI TWD DNT DNT NQI NQI TWD NQI NQI NQI NQI NQI NQI NQI NQI NQI TWD NQI DNT DNT DNT DNT DNT DNT DNT DNT NQI DNT DNT DNT DNT DNT DNT NQI DNT NQI NQI NQI NQI DNT DNT DNT DNT DNT DNT DNT

%TW LOCATION EXT EXT LTS

+0.00 UTE LTE LTS

+0.00 UTE LTE LTS

-0.25 UTE LTE LTS

+0.00 UTE LTE LTS

+0.00 UTE LTE 010

+10.51 UTE LTE LTS

-0.07 UTE LTE LTS

-0.04 UTE LTE LTS

+0.00 UTE LTE LTS

-0.04 UTE LTE UTS

-0.17 UTE LTE UTS

+0.02 UTE LTE 015

+0.68 UTE LTE UTS

-0.81 UTE LTE 012

+28.42 UTE LTE 015

+12.69 UTE LTE LTS

+21.83 UTE LTE LTS

+0.00 UTE LTE LTS

+0.00 UTE LTE LTS

+0.00 UTE LTE LTS

+0.07 UTE LTE LTS

+0.00 UTE LTE LTS

+0.02 UTE LTE LTS

+0.00 UTE LTE LTS

+0.09 UTE LTE LTS

+0.00 UTE LTE LTS

+0.04 UTE LTE LTS

+0.00 UTE LTE LTS

-0.02 UTE LTE 011

+22.09 UTE LTE 16 012

+21.99 UTE LTE LTS

-0.02 UTE LTE LTS

-0.02 UTE LTE 014

+0.72 UTE LTE 014

+0.74 UTE LTE 20 015

+44.57 UTE LTE 010

+0.46 UTE LTE 011

+0.46 UTE LTE 011

+4.28 UTE LTE 012

+34.53 UTE LTE 009

-0.79 UTE LTE 013

+25.11 UTE LTE 012

+29.11 UTE LTE 010

+14.08 UTE LTE 015

+32.33 UTE LTE 28 014

+29.49 UTE LTE 014

+17.46 UTE LTE LTS

+0.00 UTE LTE LTS

+0.00 UTE LTE LTS

+0.00 UTE LTE LTS

+0.04 UTE LTE LTS

+0.00 UTE LTE LTS

+0.04 UTE LTE LTS

+0.04 UTE LTE LTS

+0.09 UTE LTE 014

+0.40 UTE LTE LTS

+0.00 UTE LTE LTS

+0.00 UTE LTE LTS

+0.07 UTE LTE LTS

+0.02 UTE LTE LTS

+0.02 UTE LTE LTS

-0.04 UTE LTE 003

+25.92 UTE LTE LTS

+0.04 UTE LTE 013

+0.37 UTE LTE 013

+18.90 UTE LTE 013

+0.72 UTE LTE 009

+5.94 UTE LTE LTS

-0.28 UTE LTE LTS

+0.00 UTE LTE LTS

+0.00 UTE LTE LTS

+0.00 UTE LTE LTS

+0.00 UTE LTE LTS

+0.07 UTE LTE LTS

+0.09 UTE LTE UTIL 1 UTIL 2

==

CAL #

36 33 36 95 95 95 95 96 95 96 95 96 96 96 26 19 19 19 33 36 33 36 33 36 122 95 96 95 96 96 96 95 96 95 95 96 96 19 19 26 19 19 19 19 26 26 26 36 33 36 33 36 126 127 126 127 127 122 100 99 100 99 99 100 95 95 126 19 26 33 36 33 36 33 33 LEG OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET PROBE 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 5lOUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL SlOUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL SOUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL

Framatome ANP Inc.

12/05/01 14:26:27 Customer Name: Oconee Unit 3 Component: S/G B Page 10 of 30 ATTACHMENT #2 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL 4 LEG PROBE 54 63 6.27 172 P 1==NT LTS

+0.00 UTE LTE 36 OUTLET 51OUL 54 65 6.20 184 P 1 DNT LTS

+0.24 UTE LTE 126 OUTLET 51OUL 54 66 6.27 183 P 1 DNT LTS

+0.13 UTE LTE 126 OUTLET 51OUL 54 68 6.11 189 P 1 DNT LTS

+0.13 UTE LTE 126 OUTLET 51OUL 54 69 10.46 177 P 1 DNT LTS

+0.00 UTE LTE 127 OUTLET 51OUL 54 70 11.45 186 P 1 DNT LTS

+0.15 UTE LTE 126 OUTLET 51OUL 54 71 8.83 178 P 1 DNT LTS

+0.00 UTE LTE 127 OUTLET 51OUL 54 75 9.83 180 P 1 DNT LTS

+0.11 UTE LTE 100 OUTLET 51OUL 54 76 27.36 187 P 1 DNT LTS

+0.04 UTE LTE 99 OUTLET 51OUL 54 77 13.44 179 P 1 DNT LTS

+0.00 UTE LTE 100 OUTLET 51OUL 54 78 7.03 192 P 1 DNT LTS

+0.00 UTE LTE 99 OUTLET 51OUL 54 79 7.40 178 P 1 DNT LTS

-0.17 UTE LTE 100 OUTLET 51OUL 54 80 9.16 189 P 1 DNT LTS

-0.06 UTE LTE 99 OUTLET 51OUL 54 93 0.36 103 3 NQI 003

+31.41 UTE LTE 100 OUTLET 51OUL 54 124 1.33 117 3 NQI 013

+1.29 UTE LTE 99 OUTLET 51OUL 55 29 0.23 59 P 1 NQI 009

+0.29 UTE LTE 30 OUTLET 51OUL 55 45 0.40 80 3

NQI 008

+11.12 UTE LTE 30 OUTLET 51OUL 55 48 0.31 66 3

NQI 007

+10.21 UTE LTE 29 OUTLET 51OUL 55 54 7.44 182 P 1 DNT LTS

-0.02 UTE LTE 29 OUTLET 51OUL 55 55 8.51 175 P 1 DNT LTS

+0.00 UTE LTE 36 OUTLET 51OUL 55 56 9.96 186 P 1 DNT LTS

+0.04 UTE LTE 33 OUTLET 51OUL 55 57 12.49 177 P 1 DNT LTS

+0.00 UTE LTE 36 OUTLET 51OUL 55 58 16.08 185 P 1 DNT LTS

+0.07 UTE LTE 33 OUTLET 51OUL 55 59 12.58 175 P 1 DNT LTS

+0.00 UTE LTE 36 OUTLET 51OUL 55 60 6.07 186 P 1 DNT LTS

+0.04 UTE LTE 33 OUTLET 51OUL 55 65 6.74 176 P 1 DNT LTS

+0.00 UTE LTE 127 OUTLET 51OUL 55 66 7.16 182 P 1 DNT LTS

+0.04 UTE LTE 126 OUTLET 51OUL 55 68 9.44 184 P 1 DNT LTS

+0.11 UTE LTE 126 OUTLET 51OUL 55 69 13.26 177 P 1 DNT LTS

+0.00 UTE LTE 127 OUTLET 51OUL 55 70 13.40 184 P 1 DNT LTS

+0.15 UTE LTE 126 OUTLET 51OUL 55 71 9.41 178 P 1 DNT LTS

+0.00 UTE LTE 127 OUTLET 51OUL 55 72 6.28 189 P 1 DNT LTS

+0.04 UTE LTE 126 OUTLET 51OUL 55 73 12.74 179 P 1 DNT LTS

+0.00 UTE LTE 127 OUTLET 51OUL 55 74 10.63 188 P 1 DNT LTS

+0.09 UTE LTE 99 OUTLET 51OUL 55 75 18.50 185 P 1 DNT LTS

+0.04 UTE LTE 114 OUTLET 51OUL 55 76 14.04 187 P 1 DNT LTS

+0.09 UTE LTE 99 OUTLET 51OUL 55 77 20.16 180 P 1 DNT LTS

+0.04 UTE LTE 100 OUTLET 51OUL 55 78 10.08 188 P 1 DNT LTS

+0.02 UTE LTE 99 OUTLET 51OUL 55 79 14.42 180 P 1 DNT LTS

+0.00 UTE LTE 100 OUTLET 51OUL 55 82 0.24 97 3

NQI 008

+9.31 UTE LTE 99 OUTLET 51OUL 55 108 0.22 90 3

NQI 014

+1.37 UTE LTE 99 OUTLET 51OUL 55 120 0.63 117 P 1 NQI 008

-0.59 UTE LTE 99 OUTLET 51OUL 56 9

0.32 52 3

NQI 015

+39.49 UTE LTE 29 OUTLET 51OUL 56 18 0.25 87 3

NQI 009

+33.08 UTE LTE 30 OUTLET 51OUL 56 21 0.26 69 3

NQI 011

+26.31 UTE LTE 29 OUTLET 51OUL 56 32 0.28 90 3

NQI 011

+33.65 UTE LTE 30 OUTLET 51OUL 56 39 0.33 87 3

NQI 012

+10.83 UTE LTE 29 OUTLET 51OUL 56 53 7.78 176 P 1 DNT LTS

-0.02 UTE LTE 30 OUTLET 51OUL 56 54 0.36 63 3

NQI 012

+29.60 UTE LTE 29 OUTLET 51OUL 8.51 183 P 1 DNT LTS

+0.00 UTE LTE 29 OUTLET 51OUL 56 55 6.06 173 P 1 DNT LTS

+0.04 UTE LTE 36 OUTLET 51OUL 56 57 8.23 173 P 1 DNT LTS

+0.00 UTE LTE 36 OUTLET 51OUL 56 58 21.71 186 P 1 DNT LTS

+0.02 UTE LTE 33 OUTLET 51OUL 56 59 16.38 176 P 1 DNT LTS

+0.00 UTE LTE 36 OUTLET 51OUL 56 60 11.85 187 P 1 DNT LTS

+0.07 UTE LTE 33 OUTLET 51OUL 56 61 6.52 172 P 1 DNT LTS

+0.00 UTE LTE 36 OUTLET 51OUL 56 62 10.70 187 P 1 DNT LTS

+0.07 UTE LTE 33 OUTLET 51OUL 56 63 7.18 173 P 1 DNT LTS

+0.00 UTE LTE 36 OUTLET 51OUL 56 64 6.36 186 P 1 DNT LTS

+0.11 UTE LTE 33 OUTLET 51OUL 56 65 7.44 187 P 1 DNT LTS

+0.11 UTE LTE 126 OUTLET 51OUL 56 70 9.79 185 P 1 DNT LTS

+0.15 UTE LTE 126 OUTLET 51OUL 56 71 7.72 177 P 1 DNT LTS

+0.00 UTE LTE 127 OUTLET 51OUL 56 73 9.69 175 P 1 DNT LTS

+0.00 UTE LTE 127 OUTLET 51OUL 56 74 12.98 187 P 1 DNT LTS

+0.02 UTE LTE 126 OUTLET 51OUL 56 75 11.40 188 P 1 DNT LTS

+0.09 UTE LTE 99 OUTLET 51OUL 56 76 12.30 179 P 1 DNT LTS

+0.00 UTE LTE 100 OUTLET 51OUL 56 77 10.18 187 P 1 DNT LTS

+0.07 UTE LTE 99 OUTLET 51OUL 56 78 7.94 183 P 1 DNT LTS

+0.07 UTE LTE 114 OUTLET 51OUL 56 79 17.78 177 P 1 DNT LTS

-0.02 UTE LTE 115 OUTLET 51OUL 56 80 14.67 179 P 1 DNT LTS

-0.06 UTE LTE 100 OUTLET 51OUL 56 82 7.38 177 P 1 DNT LTS

+0.00 UTE LTE 100 OUTLET 51OUL 56 93 7.23 177 3 DNT UTS

+6.60 UTE LTE 101 OUTLET 51OUL 56 110 0.62 104 3 TWD 15 011

+1.27 UTE LTE 114 OUTLET 51OUL 56 126 0.37 90 P 1 NQI 009

-0.62 UTE LTE 102 OUTLET 51OUL 57 1

9.80 180 3 DNT UTS

+12.93 UTE LTE 30 OUTLET 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:26:27 Component: S/G B Page 11 of 30 ATTACHMENT #2 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW TUBE VOLTS 28.08 57 2

12.36 24.88 57 5

0.35 0.17 57 10 0.60 57 27 0.27 57 42 0.41 57 52 6.07 57 53 11.16 57 54 10.51 57 55 0.68 7.32 57 56 7.68 57 57 11.70 57 58 14.14 57 59 12.57 57 60 8.23 0.23 57 61 9.49 57 62 10.48 57 63 13.00 57 64 7.18 57 73 9.83 57 74 28.70 57 75 26.46 57 76 8.18 57 77 8.22 0.25 57 78 6.56 57 79 8.05 57 80 14.19 57 81 12.91 57 82 8.48 57 92 10.12 57 93 0.34 57 114 0.54 57 122 0.64 58 3

8.11 0.32 21.99 13.89 58 4

0.65 58 41 8.60 58 54 7.89 58 55 0.19 12.47 58 56 9.26 58 57 14.07 58 58 6.27 58 59 8.13 58 60 10.71 58 61 21.68 58 62 19.56 58 63 10.83 58 70 6.27 58 73 7.83 58 74 19.00 58 75 16.69 58 76 23.82 58 77 13.04 58 78 6.99 58 79 6.44 58 80 9.13 58 81 8.17 58 82 11.05 58 83 10.47 58 91 11.59 58 92 28.79 58 93 15.81 58 94 0.63 58 124 0.69 58 125 0.54 59 1

26.34 59 5

8.18 DEG CHN 179 3 178 3 178 3 106 3 113 3 103 3 62 3

108 3 174 P 1 184 P 1 183 P 1 69 3

187 P 1 175 P 1 187 P 1 176 P 1 188 P 1 175 P 1 88 3

186 P 1 176 P 1 185 P 1 185 P 1 188 P 1 181 P 1 186 P 1 184 P 1 178 P 1 96 3

183 P 1 179 P 1 185 P 1 177 P 1 187 P 1 195 P 1 90 3

76 3

80 P 1 181 3 87 P 1 179 3 177 3 60 P 1 188 3 182 P 1 99 3

185 P 1 185 P 1 187 P 1 168 P 1 186 P 1 175 P 1 188 P 1 177 P 1 186 P 1 174 P 1 190 P 1 183 P 1 189 P 1 185 P 1 178 P 1 180 P 1 176 P 1 185 P 1 177 P 1 183 P 1 175 P 1 185 P 1 190 P 1 185 P 1 103 3 117 P 1 79 P 1 179 3 178 3 IND %TW LOCATION EXT DNT LTE

+10.97 UTE DNT UTS

+13.05 UTE DNT LTE

+10.94 UTE NQI 001

+3.19 UTE NQI LTS

+24.52 UTE NQI 011

+1.07 UTE NQI 011

+12.99 UTE NQI 007

+15.96 UTE DNT LTS

-0.06 UTE DNT LTS

+0.00 UTE DNT LTS

+0.04 UTE NQI LTS

+3.90 UTE DNT LTS

+0.07 UTE DNT LTS

+0.00 UTE DNT LTS

+0.04 UTE DNT LTS

+0.00 UTE DNT LTS

+0.04 UTE DNT LTS

+0.00 UTE NQI 012

+28.36 UTE DNT LTS

+0.07 UTE DNT LTS

+0.00 UTE DNT LTS

+0.09 UTE DNT LTS

+0.11 UTE DNT LTS

+0.24 UTE DNT LTS

+0.00 UTE DNT LTS

+0.13 UTE DNT LTS

+0.09 UTE DNT LTS

+0.00 UTE NQI 012

+33.57 UTE DNT LTS

+0.11 UTE DNT LTS

+0.00 UTE DNT LTS

+0.26 UTE DNT LTS

+0.00 UTE DNT LTS

+0.22 UTE DNT LTS

-0.19 UTE NQI 008

+16.42 UTE NQI 011

+7.54 UTE NQI 010

+0.48 UTE DNT UTS

+14.29 UTE NQI 010

+0.11 UTE DNT LTE

+11.10 UTE DNT UTS

+13.56 UTE NQI 009

+0.70 UTE DNT UTS

+9.32 UTE DNT LTS

+0.04 UTE NQI 011

+33.27 UTE DNT LTS

+0.07 UTE DNT LTS

+0.07 UTE DNT LTS

+0.09 UTE DNT LTS

+0.00 UTE DNT LTS

+0.04 UTE DNT LTS

+0.00 UTE DNT LTS

+0.09 UTE DNT LTS

+0.00 UTE DNT LTS

+0.09 UTE DNT LTS

+0.00 UTE DNT LTS

+0.35 UTE DNT LTS

+0.00 UTE DNT LTS

-0.04 UTE DNT LTS

+0.11 UTE DNT LTS

+0.07 UTE DNT LTS

+0.13 UTE DNT LTS

+0.09 UTE DNT LTS

-0.09 UTE DNT LTS

+0.02 UTE DNT LTS

+0.07 UTE DNT LTS

+0.02 UTE DNT LTS

-0.20 UTE DNT LTS

-0.17 UTE DNT LTS

-0.13 UTE NQI 002

+23.96 UTE NQI 009

-0.79 UTE NQI 009

+0.66 UTE DNT LTE

+10.89 UTE DNT LTS

+14.65 UTE EXT LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTIL 1 UTIL 2 CAL #

30 30 30 29 29 30 29 29 30 29 29 29 29 36 33 36 33 36 36 33 36 33 33 126 127 126 101 102 102 101 102 101 102 101 101 102 102 102 30 30 30 30 29 29 29 29 29 29 33 36 33 36 33 36 33 127 126 127 126 101 102 101 102 101 102 101 102 102 101 102 101 116 116 30 30 LEG PROBE OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 510UL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET SlOUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:26:27 Component: S/G B Page 12 of 30 ATTACHMENT #2 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW TUBE VOLTS 59 6

0.28 0.21 59 8

0.97 59 17 0.34 0.31 59 20 0.20 59 39 0.52 0.40 59 52 15.47 59 53 11.83 59 54 7.50 59 55 7.81 59 57 6.16 59 58 14.02 59 59 12.10 59 60 8.57 59 64 6.05 59 73 27.23 59 74 36.78 59 75 16.89 59 76 11.05 59 77 7.29 59 78 9.05 59 81 11.36 59 88 12.85 59 89 39.04 0.26 59 90 32.28 59 91 13.64 59 96 0.95 59 101 6.07 59 118 0.65 0.32 59 120 0.73 0.53 0.53 59 121 0.51 0.56 59 122 0.43 1.07 60 17 0.23 60 22 0.28 60 32 0.24 60 54 6.71 60 56 9.26 60 60 7.72 60 61 6.41 60 62 6.59 60 70 9.86 60 72 6.66 60 75 7.99 60 76 14.63 60 77 18.44 60 78 13.94 0.48 60 79 11.40 60 80 8.12 60 81 6.42 60 82 8.41 60 83 7.70 60 84 6.92 60 86 6.03 60 87 6.31 60 92 10.39 60 93 26.39 60 94 33.45 60 95 8.88 60 115 10.05 60 117 8.53 60 118 8.87 60 124 0.82 60 126 0.49 61 1

17.78 61 2

0.92 61 28 0.63 DEG CHN IND 39 3

NQI 122 3 NQI 111 P 1 NQI 90 3

NQI 102 3 NQI 81 3

NQI 82 3

NQI 106 3 NQI 180 P 1 DNT 187 P 1 DNT 175 P 1 DNT 188 P 1 DNT 173 P 1 DNT 175 P 1 DNT 176 P 1 DNT 173 P 1 DNT 172 P 1 DNT 187 P 1 DNT 180 P 1 DNT 186 P 1 DNT 175 P 1 DNT 181 P 1 DNT 176 P 1 DNT 183 P 1 DNT 185 P 1 DNT 189 P 1 DNT 84 3

NQI 182 P 1 DNT 191 P 1 DNT 100 P 1 NQI 183 3 DNT 112 P 1 NQI 111 P 1 NQI 101 3 NQI 85 3

NQI 85 P 1 NQI 84 3

NQI 76 P 1 NQI 112 P 1 NQI 125 P 1 NQI 93 3

NQI 84 3

NQI 97 3

NQI 180 P 1 DNT 187 P 1 DNT 172 P 1 DNT 171 P 1 DNT 174 P 1 DNT 174 P 1 DNT 171 P 1 DNT 185 P 1 DNT 179 P 1 DNT 184 P 1 DNT 175 P 1 DNT 62 P 1 NQI 186 P 1 DNT 174 P 1 DNT 181 P 1 DNT 174 P 1 DNT 181 P 1 DNT 175 P 1 DNT 183 P 1 DNT 188 P 1 DNT 190 P 1 DNT 186 P 1 DNT 183 P 1 DNT 186 P 1 DNT 179 3 DNT 193 3 DNT 174 3 DNT 117 P 1 NQI 100 3 NQI 181 3 DNT 116 3 NQI 61 P 1 NQI

%TW LOCATION EXT EXT 011

+16.02 TO+34.08 UTE LTE 010

+13.27 TO+20.55 UTE LTE 009

-0.63 UTE LTE 010

+30.37 UTE LTE 010

+29.17 UTE LTE 010

+1.38 UTE LTE 015

+14.93 UTE LTE 009

+25.54 UTE LTE LTS

+0.04 UTE LTE LTS

+0.09 UTE LTE LTS

+0.00 UTE LTE LTS

+0.07 UTE LTE LTS

+0.10 LTE UTE LTS

+0.29 LTE UTE LTS

+0.24 LTE UTE LTS

+0.16 LTE UTE LTS

+0.18 LTE UTE LTS

+0.11 UTE LTE LTS

+0.11 UTE LTE LTS

+0.09 UTE LTE LTS

+0.09 UTE LTE LTS

+0.04 UTE LTE LTS

+0.00 UTE LTE LTS

+0.04 UTE LTE LTS

-0.22 UTE LTE LTS

-0.21 UTE LTE 014

+32.88 UTE LTE LTS

+0.00 UTE LTE LTS

-0.15 UTE LTE 013

+0.79 UTE LTE 001

+5.97 UTE LTE 009

-0.55 UTE LTE 008

-0.76 UTE LTE 009

+22.39 UTE LTE 009

+24.39 UTE LTE 009

+0.62 UTE LTE 009

+21.60 TO+30.36 UTE LTE 009

+0.64 UTE LTE 008

-0.62 UTE LTE 009

-0.66 UTE LTE 013

+6.37 UTE LTE 001

+1.47 UTE LTE 012

+26.59 UTE LTE LTS

+0.11 UTE LTE LTS

+0.09 UTE LTE LTS

+0.14 LTE UTE LTS

+0.22 LTE UTE LTS

+0.20 LTE UTE LTS

+0.16 LTE UTE LTS

+0.12 LTE UTE LTS

+0.13 UTE LTE LTS

+0.00 UTE LTE LTS

+0.09 UTE LTE LTS

+0.00 UTE LTE 005

+0.22 UTE LTE LTS

+0.15 UTE LTE LTS

+0.07 UTE LTE LTS

+0.09 UTE LTE LTS

+0.07 UTE LTE LTS

+0.04 UTE LTE LTS

+0.00 UTE LTE LTS

-0.06 UTE LTE LTS

-0.09 UTE LTE LTS

-0.19 UTE LTE LTS

-0.21 UTE LTE LTS

-0.19 UTE LTE LTS

-0.17 UTE LTE 013

+33.50 UTE LTE 015

+12.01 UTE LTE 013

+33.16 UTE LTE 009

-0.78 UTE LTE 009

+24.01 TO+37.58 UTE LTE 001

+4.80 UTE LTE 014

+1.24 UTE LTE UTS

+17.60 UTE LTE UTIL 1 UTIL 2 CAL 29 29 29 30 30 29 29 29 30 29 36 33 1

1 101 102 101 102 101 102 101 102 101 102 101 102 102 101 102 102 102 102 102 102 116 116 116 30 29 29 29 33 1

1 1

1 1

101 102 101 102 102 101 102 101 102 101 102 115 114 115 114 115 114 116 116 116 116 116 32 29 31

  1. LEG PROBE OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL INLET 51OUL INLET 51OUL INLET 51OUL INLET 51OUL INLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL INLET 51OUL INLET 51OUL INLET 51OUL INLET 51OUL INLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL

Framatome ANP Inc.

12/05/01 14:26:27 Customer Name: Oconee Unit 3 Component: S/G B Page 13 of 30 ATTACHMENT #2-LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL#

LEG PROBE 61 53 8.70 180 P 1 OUT LTS

+0.28 UTE LTE 32 OUTLET 51OUL 61 54 0.43 81 3

NQI 011

+22.50 UTE LTE 31 OUTLET 51OUL 22.81 185 P 1 DNT LTS

+0.07 UTE LTE 31 OUTLET 51OUL 61 55 8.22 190 P 1 DNT LTS

+0.04 UTE LTE 31 OUTLET 51OUL 61 58 0.58 107 P 1 NQI 013

+0.04 LTE UTE 1

INLET 51OUL 6.73 172 P 1 OUT LTS

+0.08 LTE UTE 1

INLET 51OUL 61 63 6.88 171 P 1 OUT LTS

+0.22 LTE UTE 1

INLET 51OUL 61 65 6.51 173 P 1 OUT LTS

+0.14 LTE UTE 1

INLET 51OUL 61 66 6.37 167 P 1 OUT LTS

+0.16 LTE UTE 1

INLET 51OUL 61 67 7.70 169 P 1 OUT LTS

+0.18 LTE UTE 1

INLET 51OUL 61 68 7.82 174 P 1 OUT LTS

+0.20 LTE UTE 1

INLET 51OUL 61 69 10.61 174 P 1 OUT LTS

+0.14 LTE UTE 1

INLET 51OUL 651 70 6.11 169 P 1 OUT LTS

+0.10 LTE UTE 1

INLET 51OUL 61 74 8.68 183 P 1 OUT LTS

+0.17 UTE LTE 114 OUTLET 51OUL 61 75 10.57 180 P 1 OUT LTS

+0.09 UTE LTE 115 OUTLET 51OUL 61 76 7.87 184 P 1 OUT LTS

+0.04 UTE LTE 114 OUTLET 51OUL 61 77 12.12 177 P 1 OUT LTS

+0.13 UTE LTE 115 OUTLET 51OUL 61 78 0.24 97 3

UQI 006

+29.41 UTE LTE 114 OUTLET

-S1OUL 10.96 185 P 1 OUT LTS

+0.09 UTE LTE 114 OUTLET 51OUL 61 79 12.01 176 P 1 OUT LTS

+0.00 UTE LTE 115 OUTLET 51OUL 61 80 0.38 79 3

UQI 007

+29.56 UTE LTE 114 OUTLET 51OUL 9.65 183 P 1 OUT LTS

+0.04 UTE LTE 114 OUTLET 51OUL 61 85 8.08 174 3 OUT 015

+40.47 UTE LTE 115 OUTLET 51OUL 0.67 78 P 1 UQI 015

+0.70 UTE LTE 115 OUTLET 51OUL 6.61 176 P 1 OUT LTS

-0.05 UTE LTE 115 OUTLET 51OUL 61 88 0.37 110 3 UQI 012

+34.53 UTE LTE 114 OUTLET 51OUL 61 91 7.99 189 P 1 OUT LTS

-0.17 UTE LTE 115 OUTLET 51OUL 61 92 9.63 188 P 1 OUT LTS

-0.15 UTE LTE 114 OUTLET 51OUL 61 103 9.96 181 3 OUT 001

+6.21 UTE LTE 118 OUTLET 51OUL 61 108 0.31 113 3 TWO 1 013

+23.07 UTE LTE 118 OUTLET 51OUL 61 110 0.31 85 P 1 NQI 008

+0.30 UTE LTE 118 OUTLET 51OUL 22.85 179 3 OUT LTE

+11.29 UTE LTE 118 OUTLET 51OUL 61 111 0.78 98 P 1 NQI 014

+0.75 UTE LTE 116 OUTLET 51OUL 0.37 97 3

NQI LTS

+35.06 UTE LTE 116 OUTLET 51OUL 61 121 0.91 109 P 1 NQI 009

-0.76 UTE LTE 116 OUTLET 51OUL 61 122 0.72 100 3 NQI 009

+19.97 TO+31.19 UTE LTE 116 OUTLET 51OUL 0.88 105 P 1 NQI 009

-0.61 UTE LTE 116 OUTLET 51OUL 0.69 39 P 1 UQI 009

+0.62 UTE LTE 116 OUTLET 51OUL 61 124 0.58 100 P 1 UQI 009

-0.76 UTE LTE 116 OUTLET 51OUL 0.34 108 3 UQI 010

+2.96 UTE LTE 116 OUTLET 51OUL 61 126 14.81 183 P 1 OUT 015

-0.53 UTE LTE 116 OUTLET 51OUL

0. 44 104 3 UQI 011

+7.37 TO+14.79 UTE LTE 116 OUTLET 51OUL 0.59 81 3

UQI 010

+20.29 UTE LTE 116 OUTLET SIOUL 62 4 9 6.02 179 P 1 OUT LTS

-0. 04 UTE LTE 32 OUTLET S1OUL 62 S3 8.16 177 P 1 OUT LTS

-0.04 UTE LTE 32 OUTLET 51OUL 62 54 6.74 185 P 1 OUT LTS

+0.04 UTE LTE 31 OUTLET 51OUL 62 55 10.02 180 P 1 OUT LTS

+0.00 UTE LTE 32 OUTLET 51OUL 62 S6 7.50 1 86 P 1 OUT LTS

+0.04 UTE LTE 31 OUTLET 51OUL 62 S8 8.88 186 P 1 OUT LTS

+0.09 UTE LTE 33 OUTLET 51OUL 62 59 25.89 176 P 1 OUT LTS

+0.24 LTE UTE 1

INLET 51OUL 62 60 13.21 174 P 1 OUT LTS

+0.20 LTE UTE 1

INLET 51OUL 62 63 6.63 171 P 1 OUT LTS

+0.16 LTE UTE 1

INLET 51OUL 62 64 6.11 171 P 1 OUT LTS

+0.22 LTE UTE 1

INLET SlOUL 62 65 6.34 170 P 1 OUT LTS

+0.14 LTE UTE 1

INLET 51OUL 62 66 7.29 173 P 1 OUT LTS

+0.16 LTE UTE 1

INLET 51OUL 62 67 6.73 172 P 1 OUT LTS

+0.20 LTE UTE 1

INLET 51OUL 62 70 10.00 180 P 1 OUT LTS

+0.18 LTE UTE 1

INLET 51OUL 62 71 6.73 172 P 1 OUT LTS

+0.22 LTE UTE 1

INLET SlOUL 62 73 0.28 74 3

UQI 011

+3.44 LTE UTE 1

INLET 51OUL 62 77 9.07 182 P 1 OUT LTS

+0.11 UTE LTE 114 OUTLET 51OUL 62 78 6.51 169 P 1 OUT LTS

+0.04 UTE LTE 115 OUTLET 51OUL 62 80 7.55 174 P 1 OUT LTS

-0.04 UTE LTE 115 OUTLET 51OUL 62 81 13.73 181 P 1 OUT LTS

+0.11 UTE LTE 114 OUTLET 51OUL 62 82 9.36 176 P 1 OUT LTS

+0.06 UTE LTE 115 OUTLET 51OUL 62 83 6.33 183 P 1 OUT LTS

+0.07 UTE LTE 114 OUTLET 51OUL 62 84 8.SO 174 P 1 OUT LTS

+0.04 UTE LTE 115 OUTLET 51OUL 62 85 6.12 187 P 1 OUT LTS

+0.02 UTE LTE 114 OUTLET 51OUL 62 86 7.09 176 P 1 OUT LTS

+0.02 UTE LTE 115 OUTLET SlOUL 62 108 0.26 76 P 1 UQI 014

+0.21 UTE LTE 118 OUTLET 51OUL 62 112 19.87 179 3 OUT LTE

+11.16 UTE LTE 118 OUTLET 51OUL 62 115 1.79 86 P 1 TWO 28 014

+1.30 UTE LTE 115 OUTLET 51OUL 62 129 24.67 183 P 1 OUT 015

-0.45 UTE LTE 116 OUTLET 51OUL 63 38 0.36 74 3

NQI 010

+12.92 UTE LTE 31 OUTLET 51OUL 63 S3 8.32 180 P 1 OUT LTS

-0.06 UTE LTE 32 OUTLET 51OUL 63 54 9.25 187 P 1 OUT LTS

-0.02 UTE LTE 31 OUTLET 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:26:27 Component: S/G B Page 14 of 30 ATTACHMENT #2 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW 63 63 63 63 63 63 63 63 63 63 63 63 63 63 63 63 63 63 63 63 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 66 66 66 66 66 66 66 66 66 66 TUBE VOLTS 56 6.74 57 7.24 58 16.06 59 0.70 39.75 60 39.19 61 24.49 66 0.73 7.13 67 8.33 71 8.69 73 9.14 74 9.33 78 6.08 83 6.07 84 7.96 85 6.88 113 20.79 114 17.48 128 0.88 0.74 129 16.21 130 35.02 48 0.30 0.21 54 9.46 55 6.81 57 6.25 58 6.45 59 27.76 60 24.26 61 32.48 62 13.27 67 6.67 84 6.49 85 7.55 86 6.24 124 0.81 128 47.61 129 40.06 55 6.04 58 11.46 59 19.79 60 21.60 61 12.35 62 9.70 63 10.03 64 6.11 65 7.15 66 6.23 67 10.12 69 0.33 7.47 76 0.35 84 6.20 95 0.40 99 0.57 126 6.95 1.06 127 0.44 1.05 128 1.08 129 28.88 0.72 130 31.83 24 0.27 32 0.28 41 6.08 57 0.48 59 10.00 60 14.03 61 8.28 62 8.54 63 13.28 64 18.79 DEG 187 188 186 133 177 177 179 131 170 171 177 179 189 181 177 183 170 180 180 87 75 184 182 112 106 179 189 190 178 188 177 179 177 174 171 183 168 106 182 183 181 190 175 177 172 174 171 171 172 171 172 96 167 93 179 97 103 177 104 108 143 90 184 109 182 85 53 182 71 192 174 173 173 175 175 CHN P 1 P1I P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 3

3 P1 P 1 P 1 P 1 3

3 P 1 P 1 P 1 P I P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 3

P 1 3

P 1 3

3 3

P 1 P 1 P 1 P 1 P 1 3

P 1 P 1 P 1 3

3 P 1 P 1 P 1 P 1 P 1 P 1 IND %TW LOCATION EXT

=NT LTS

+0.02 UTE DNT LTS

+0.04 UTE DNT LTS

+0.07 UTE NQI 013

+0.84 LTE DNT LTS

+0.16 LTE DNT LTS

+0.22 LTE DNT LTS

+0.26 LTE NQI 014

+0.86 LTE DNT LTS

+0.14 LTE DNT LTS

+0.10 LTE DNT LTS

+0.22 LTE DNT LTS

+0.22 LTE DNT LTS

+0.15 UTE DNT LTS

+0.00 UTE DNT LTS

+0.06 UTE DNT LTS

+0.04 UTE DNT LTS

-0.07 UTE DNT LTE

+10.76 UTE DNT LTE

+10.96 UTE TWD 26 014

+0.83 UTE NQI 009

-0.78 UTE DNT 015

-0.72 UTE DNT 015

-0.48 UTE TWD 8 014

+3.54 UTE TWD 22 013

+27.23 UTE DNT LTS

-0.11 UTE DNT LTS

-0.07 UTE DNT LTS

-0.02 UTE DNT LTS

-0.02 UTE DNT LTS

+0.07 UTE DNT LTS

+0.30 LTE DNT LTS

+0.26 LTE DNT LTS

+0.30 LTE DNT LTS

+0.14 LTE DNT LTS

+0.06 UTE DNT LTS

+0.00 UTE DNT LTS

+0.00 UTE NQI 009

-0.73 UTE DNT 015

-0.56 UTE DNT 015

-0.52 UTE DNT LTS

-0.06 UTE DNT LTS

+0.00 UTE DNT LTS

+0.02 LTE DNT LTS

+0.14 LTE DNT LTS

+0.10 LTE DNT LTS

+0.12 LTE DNT LTS

+0.08 LTE DNT LTS

+0.04 LTE DNT LTS

+0.06 LTE DNT LTS

+0.06 LTE DNT LTS

+0.04 LTE NQI 005

+30.30 LTE DNT LTS

+0.04 LTE NQI 008

+19.67 UTE DNT LTS

+0.07 UTE NQI 003

+29.35 UTE NQI 009

+17.01 UTE DNT UTS

+7.57 UTE NQI 009

-0.78 UTE NQI 008

-0.61 UTE NQI 009

-0.55 UTE NQI 009

-0.75 UTE DNT 015

-0.76 UTE NQI 009

+38.25 UTE DNT 015

-0.59 UTE NQI UTS

+0.99 UTE NQI 013

-0.22 UTE DNT LTE

+22.47 UTE NQI 008

+6.84 UTE DNT LTS

-0.07 UTE DNT LTS

+0.08 LTE DNT LTS

+0.10 LTE DNT LTS

+0.10 LTE DNT LTS

+0.16 LTE DNT LTS

+0.12 LTE EXT LTE LTE LTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTE UTE UTE UTE UTE UTIL 1 UTIL 2 CAL 31 31 31 1

1 1

1 1

1 1

1 1

12 6 114 115 114 115 118 114 115 115 114 115 32 32 32 31 31 32 31 1

1 1

1 115 114 115 115 115 115 32 31 1

1 1

1 1

1 1

1 1

1 1

114 114 115 118 115 115 114 114 115 114 114 115 31 31 32 31 31 1

1 1

1 1

LEG OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET PROBE 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:26:28 Component: S/G B Page 15 of 30 ATTACHMENT #2 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW 66 66 66 66 66 66 66 66 66 66 66 66 66 66 66 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 69 69 69 69 69 69 69 69 69 69 69 69 69 69 69 TUBE VOLTS 66 7.66 67 21.73 68 24.37 69 0.20 29.78 70 24.58 71 13.90 72 13.11 73 6.10 99 0.18 111 0.24 127 1.07 128 0.57 129 0.59 130 31.30 7.96 131 1.21 48.60 1

7.62 59 6.31 60 6.26 61 6.78 63 15.66 64 12.94 65 19.90 66 17.65 0.25 67 32.17 68 33.02 69 30.58 70 35.38 71 14.15 72 8.80 86 7.15 107 0.51 129 0.79 130 42.01 5

0.44 38 0.23 40 0.54 60 6.03 62 6.09 63 6.70 64 6.93 65 9.30 66 6.25 68 9.64 69 16.09 70 34.09 71 30.52 72 23.38 82 0.36 86 9.70 88 8.47 89 7.55 113 0.42 0.36 123 0.45 130 14.62 131 28.99 4

0.36 9

0.28 19 12.83 24 0.38 25 0.52 71 12.53 72 24.32 73 7.13 79 0.31 81 1.08 83 0.23 86 8.56 87 10.54 89 8.89 90 6.45 DEG CHN 170 P 1 176 P 1 176 P 1 105 3 175 P 1 176 P 1 176 P 1 178 P 1 181 P 1 70 P 1 77 3

87 3

152 P 1 95 P 1 185 P 1 20 P 1 113 3 181 P 1 180 3 194 P 1 171 P 1 172 P 1 174 P 1 175 P 1 175 P 1 177 P 1 85 3

175 P 1 176 P 1 176 P 1 177 P 1 176 P 1 170 P 1 181 P 1 108 3 74 P 1 184 P 1 80 P 1 80 3

91 P 1 172 P 1 173 P 1 174 P 1 174 P 1 175 P 1 175 P 1 176 P 1 175 P 1 177 P 1 177 P 1 175 P 1 96 3

188 P 1 186 P 1 177 P 1 66 3

102 3 50 P 1 184 P 1 182 P 1 95 P 1 105 3 176 3 87 3

71 3

178 P 1 176 P 1 168 P 1 100 3 91 P 1 93 3

171 P 1 174 P 1 173 P 1 177 P 1 IND %TW LOCATION DNT LTS

+0.04 DNT LTS

+0.10 DNT LTS

+0.12 NQI 011

+22.95 DNT LTS

+0.10 DNT LTS

+0.14 DNT LTS

+0.22 DNT LTS

+0.18 DNT LTS

+0.36 NQI 014

-0.27 NQI 011

+25.93 NQI 009

+23.03 NQI 009

-0.74 NQI 009

-0.65 DNT 015

-0.53 NQI UTS

-0.09 NQI 015

+5.19 DNT 015

-0.54 DNT 009

+38.55 DNT LTS

-0.09 DNT LTS

+0.08 DNT LTS

+0.08 DNT LTS

+0.02 DNT LTS

+0.06 DNT LTS

+0.08 DNT LTS

+0.06 NQI 012

+8.71 DNT LTS

+0.12 DNT LTS

+0.10 DNT LTS

+0.14 DNT LTS

+0.20 DNT LTS

+0.22 DNT LTS

+0.12 DNT LTS

+0.00 NQI 015

+42.00 TO+45.50 NQI 015

-0.46 DNT 015

-0.46 NQI 011

+0.00 NQI 010

+4.17 NQI 014

-0.17 DNT LTS

+0.00 DNT LTS

+0.04 DNT LTS

+0.02 DNT LTS

+0.02 DNT LTS

+0.02 DNT LTS

+0.08 DNT LTS

+0.06 DNT LTS

+0.10 DNT LTS

+0.10 DNT LTS

+0.14 DNT LTS

+0.08 TWD 38 013

+16.98 DNT LTS

+0.09 DNT LTS

+0.02 DNT LTS

-0.06 NQI LTS

+13.20 NQI 001

+2.47 NQI 009

-0.79 DNT 015

-0.61 DNT 015

-0.55 NQI 009

-0.72 NQI 001

+33.75 DNT 003

+5.05 NQI 012

+24.14 NQI 004

+6.71 DNT LTS

+0.06 DNT LTS

+0.08 DNT LTS

+0.06 NQI 006

+37.40 NQI UTS

+12.58 NQI 008

+28.84 DNT LTS

+0.09 DNT LTS

+0.19 DNT LTS

-0.04 DNT LTS

-0.02 EXT EXT LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE 014 LTE UTE LTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE UTE LTE UTE LTE UTE LTE UTE LTE 014 LTE UTE LTE UTE LTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE 014 LTE 014 LTE UTE LTE UTE LTE UTE LTE LTE UTE LTE UTE LTE UTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTIL 1 UTIL 2 CAL 1

1 1

1 1

1 11 118 118 115 114 115 114 114 115 115 13S 31 1

1 1

1 1

1 1

1 1

1 1

112 135 132 313 32 32 1

1 1

112 112 112 112 112 11 11 112 112 111 311 112 11 11 111 112 112 311 312 112 112 LEG INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET PROBE 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL S5OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:26:28 Component: S/G B Page 16 of 30 ATTACHMENT #2 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW 69 70 70 70 70 70 70 70 70 70 70 71 71 71 71 71 71 71 71 71 71 71 71 71 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 73 TUBE 131 3

71 72 87 88 89 93 111 123 131 5

6 38 68 71 72 86 87 88 89 93 125 131 5

6 12 13 19 41 58 68 71 72 73 83 85 86 87 88 89 92 93 99 129 5

6 9

10 13 29 49 70 71 72 83 84 85 86 87 88 89 91 92 VOLTS 10.32 19.34 0.42 10.06 9.80 7.10 8.53 7.19 6.43 0.91 0.80 14.24 0.75 0.54 0.64 0.85 0.22 0.46 10.49 10.30 9.21 13.88 12.24 10.20 11.07 7.44 0.29 1.29 0.36 0.72 0.28 0.40 0.57 0.58 0.35 1.09 1.08 0.33 0.53 10.11

14. 65 6.13 6.83 0.34
13. 15 19.21 11.76 15.14 7.61
8. 65 7.14 0.29 0.34 0.37 0.52 0.31 0.90 0.77 0.27 0.24 0.33 0.26 6.45 13.74 14.98 10.22 8.54 21.46 16.41
12. 65 6.28 11.08 6.61 7.48 9.16 DEG CHN IND 185 P 1=NT 182 P 1 DNT 71 P 1 NQI 176 P 1 DNT 177 P 1 DNT 171 P 1 DNT 189 P 1 DNT 177 P 1 DNT 174 P 1 DNT 91 P 1 NQI 89 P 1 NQI 191 P 1 DNT 111 P 1 NQI 126 P 1 NQI 74 P 1 NQI 90 3

NQI 102 3 NQI 108 3 NQI 177 P 1 DNT 175 P 1 DNT 176 P 1 DNT 191 P 1 DNT 181 3 DNT 181 P 1 DNT 189 P 1 DNT 192 P 1 DNT 68 P 1 NQI 45 P 1 NQI 96 P 1 NQI 113 3 NQI 77 P 1 NQI 90 3

NQI 98 3

NQI 105 P 1 NQI 97 P 1 NQI 109 P 1 NQI 96 P 1 NQI 83 P 1 NQI 89 3

NQI 178 P 1 DNT 177 P 1 DNT 173 P 1 DNT 177 P 1 DNT 67 3

NQI 179 P 1 DNT 177 P 1 DNT 180 P 1 DNT 179 P 1 DNT 187 P 1 DNT 180 P 1 DNT 182 P 1 DNT 55 P 1 NQI 86 3

NQI 96 3

NQI 89 P 1 NQI 86 P 1 NQI 111 P 1 NQI 109 3 NQI 90 3

NQI 69 P 1 NQI 97 P 1 NQI 85 3

NQI 179 P 1 DNT 177 P 1 DNT 177 P 1 DNT 178 3 DNT 180 P 1 DNT 178 P 1 DNT 182 P 1 DNT 177 P 1 DNT 182 P 1 DNT 177 P 1 DNT 187 P 1 DNT 188 P 1 DNT 177 P 1 DNT

%TW LOCATIC 010 015 014 LTS LTS LTS LTS LTS LTS 006 014 010 009 010 011 006 013 001 LTS LTS LTS LTS 002 LTS LTS LTS 010 015 015 010 011 010 010 012 012 011 010 014 010 LTS LTS LTS LTS 014 LTS LTS LTS LTS LTS LTS LTS 014 004 010 012 011 013 011 011 002 011 005 LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS ON

-0.24

-0.57

-0.04

+0.00

+0.04

+0.00

+0.00

-0.07

+0.00

-0.54

+0.85

+0.00

-0.68

+0.50

+0.39

+7.56

+24.00

+33.85

+0.00

+0.04

+0.09

+0.07

+11.74

+0.00

+0.00

+0.00

+0.22

-0.34

+0.43

+8.23

-0.04

+12.24

+8.63

+0.54

+0.33

+0.51

+0.46

-0.16

+13.85

+0.02

+0.10

+0.20

+0.02

+31.88

+0.04

+0.09

+0.04

+0.00

-0.34

+0.00

-0.06

+1.00

+7.09

+31.90

+0.46

-1.00

+0.42

+5.51

+5.94

-0.26

+0.44

+24.53

+0.02

+0.08

+0.13

+0.46

-0.02

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00 EXT UTE UTE 014 LTE LTE UTE UTE UTE UTE UTE UTE UTE 014 014 014 014 UTE LTE LTE LTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 014 014 014 014 UTE UTE UTE UTE LTE LTE LTE LTE LTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 014 014 014 014 014 014 UTE UTE UTE LTE LTE LTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE EXT LTE LTE LTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTIL 1 UTIL 2 CAL 112 112 134 1

1 112 ill 112 112 111 112 112 135 134 134 134 33 1

1 1

112 ill 112 112 111 111 107 108 108 134 135 135 135 36 33 33 33 4

4 4

4 4

108 108 107 108 107 108 107 108 107 107 107 135 134 134 135 134 134 36 36 36 4

4 4

107 107 108 107 108 107 108 107 107 108

  1. LEG OUTLET OUTLET OUTLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET PROBE 51 OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:26:28 Component: S/G B Page 17 of 30 ATTACHMENT #2 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW 73 73 73 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 74 75 75 75 75 75 75 75 75 75 75 75 75 75 75 75 75 75 75 75 75 75 75 75 75 75 75 75 75 75 75 75 75 76 76 76 76 76 76 TUBE VOLTS 103 0.47 110 0.25 125 0.39 1

24.89 33 0.32 44 6.20 47 0.30 54 6.13 55 6.48 57 6.29 58 0.36 6.51 59 6.38 63 0.51 64 7.46 66 10.85 67 9.25 68 10.79 72 0.30 75 0.21 78 6.01 79 24.94 80 17.58 82 6.17 83 9.67 84 10.41 87 8.40 99 6.38 121 0.38 124 0.49 1

22.34 13 0.37 21 0.22 22 0.19 0.25 34 0.29 42 6.71 48 6.17 49 6.62 54 6.17 56 6.24 58 6.04 59 6.41 61 6.29 63 6.29 67 14.20 68 13.70 69 14.68 71 0.20 79 9.53 80 24.36 81 15.88 82 9.14 84 9.75 87 8.56 88 8.18 99 0.58 111 8.24 0.83 112 0.71 116 0.31 118 0.92 121 0.85 123 0.27 64 7.76 66 7.56 67 15.59 68 19.29 69 19.00 76 0.25 0.21 0.31 0.25 6.33 0.33 DEG 90 86 79 181 99 187 94 182 177 180 92 182 179 80 183 179 177 176 89 69 183 180 183 183 177 185 179 170 77 107 180 103 78 70 64 76 184 184 180 184 186 178 182 186 182 179 178 177 74 181 178 182 175 175 187 180 97 194 136 95 94 48 71 107 182 179 176 176 178 94 103 93 77 169 63 CHN 3

3 P 1 3

3 P 1 3

P 1 P 1 P 1 3

P 1 P 1 P 1 P 1 P 1 P1 P1 3

3 P 1 P 1 P 1 P 1 P 1 P 1 P1 3

3 3

3 3

3 3

3 3

P 1 P 1 P I P 1 P I P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P1I P 1 3

3 P1 P 1 P 1 P 1 3

P 1 P 1 P 1 P 1 P1 3

3 3

3 P 1 P 1 IND NQI NQI NQI DNT NQI DNT NQI DNT DNT DNT NQI DNT DNT NQI DNT NNT DNT DNT NQI NQI DNT DNT DNT DNT DNT DNT DNT DNT NQI NTI DNT NQI NQI NQI DNT DNT DNT NNT DNT NNT NNT NNT NNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT NQI DNT NQI NTI NTI NTI NTI NTI DNT DNT DNT DNT DNT NQI NQI NQI NQI DNT NQI

%TW LOCATION EXT EXT 009

+27.30 UTE LTE 014

+22.87 UTE LTE 010

+0.45 UTE LTE LTE

+10.94 014 LTE 010

+12.11 014 LTE UTS

+0.05 UTE LTE 015

+13.55 UTE LTE UTS

+0.02 UTE LTE UTS

+0.00 UTE LTE UTS

+0.02 LTE UTE 010

+18.13 LTE UTE UTS

+0.04 LTE UTE UTS

+0.10 LTE UTE 006

+0.68 LTE UTE UTS

+0.10 LTE UTE LTS

+0.00 LTE UTE LTS

+0.04 LTE UTE LTS

+0.11 LTE UTE 009

+20.31 UTE LTE 010

+10.05 UTE LTE LTS

+0.13 UTE LTE LTS

+0.04 UTE LTE LTS

+0.00 UTE LTE LTS

+0.00 UTE LTE LTS

+0.00 UTE LTE LTS

+0.00 UTE LTE LTS

+0.04 UTE LTE 013

+31.27 UTE LTE 011

+32.58 UTE LTE 014

+1.18 UTE LTE LTE

+10.76 014 LTE LTS

+33.22 014 LTE 008

+12.77 014 LTE 006

+17.10 014 LTE 006

+15.39 014 LTE 006

+1.38 014 LTE UTS

+0.04 UTE LTE UTS

+0.04 UTE LTE UTS

+0.00 UTE LTE UTS

+0.02 UTE LTE UTS

+0.04 UTE LTE UTS

+0.00 LTE UTE UTS

+0.06 LTE UTE UTS

+0.10 LTE UTE UTS

+0.08 LTE UTE LTS

+0.00 LTE UTE LTS

+0.02 LTE UTE LTS

+0.19 LTE UTE 008

-0.27 LTE UTE LTS

+0.00 UTE LTE LTS

+0.09 UTE LTE LTS

+0.00 UTE LTE LTS

+0.11 UTE LTE LTS

+0.00 UTE LTE LTS

+0.00 UTE LTE LTS

+0.00 UTE LTE 011

+33.39 UTE LTE LTE

+4.51 UTE LTE 014

+1.00 UTE LTE 014

+1.11 UTE LTE 008

+0.99 UTE LTE 008

+0.71 UTE LTE 003

-0.76 UTE LTE 014

+1.26 UTE LTE UTS

+0.10 LTE UTE LTS

-0.04 LTE UTE LTS

-0.04 LTE UTE LTS

+0.13 LTE UTE LTS

+0.17 LTE UTE 006

+15.07 UTE LTE 006

+13.07 UTE LTE 009

+3.05 UTE LTE 009

+2.09 UTE LTE LTS

+0.04 UTE LTE 009

+0.40 UTE LTE UTIL 1 UTIL 2 CAL #

107 108 107 135 134 33 36 33 36 4

4 4

4 4

4 4

4 4

107 108 107 108 107 107 108 107 108 107 107 108 135 134 134 135 135 135 33 33 36 33 33 4

4 4

4 4

4 4

4 107 108 107 108 108 107 108 107 107 107 108 108 108 107 107 4

4 4

4 4

118 118 118 118 118 118 LEG OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET PROBE 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL SlOUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:26:28 Component: SiG B Page 18 of 30 ATTACHMENT #2 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryM1 ROW TUBE VOLTS 76 77 7.83 76 78 9.97 76 79 15.32 76 80 22.21 76 81 10.12 76 82 7.44 76 83 18.12 76 84 8.39 76 87 6.71 76 98 0.47 0.52 0.35 77 3

32.79 77 8

8.74 77 22 26.51 77 25 0.47 77 43 6.42 77 44 0.47 77 50 0.26 77 51 6.17 77 53 6.17 77 54 6.72 77 56 6.44 77 61 8.41 0.55 77 63 8.94 77 64 6.81 77 66 0.37 77 67 6.05 77 68 13.97 77 69 25.79 77 70 18.34 77 77 7.86 77 78 9.74 77 79 10.52 77 80 10.57 77 81 12.04 77 83 8.17 77 84 21.50 77 85 6.12 77 87 7.02 77 108 0.45 78 8

6.80 78 9

19.61 78 10 7.55 17.01 78 11 15.13 15.06 78 12 27.22 78 13 19.74 25.07 78 14 0.37 24.57 20.05 78 15 29.84 78 17 16.02 20.01 78 18 25.84 78 19 8.44 20.56 23.76 78 20 0.64 17.50 17.20 78 21 19.83 78 34 1.03 78 40 6.77 78 42 6.88 0.71 78 44 6.92 0.62 78 45 6.07 78 46 6.45 0.50 78 50 6.85 DEG CHN IND 176 P 1 DNT 178 P 1 DNT 179 P 1 DNT 180 P 1 DNT 179 P 1 DNT 176 P 1 DNT 179 P 1 DNT 180 P 1 DNT 179 P 1 DNT 105 3 NQI 111 3 NQI 86 3

NQI 180 3 DNT 179 3 DNT 181 3 DNT 126 3 NQI 179 P 1 DNT 83 P 1 NQI 90 P 1 NQI 182 P 1 DNT 183 P 1 DNT 183 P 1 DNT 185 P 1 DNT 189 P 1 DNT 82 3

NQI 188 P 1 DNT 188 P 1 DNT 97 3

NQI 182 P 1 DNT 188 P 1 DNT 180 P 1 DNT 185 P 1 DNT 184 P 1 DNT 180 P 1 DNT 186 P 1 DNT 183 P 1 DNT 184 P 1 DNT 186 P 1 DNT 185 P 1 DNT 186 P 1 DNT 185 P 1 DNT 111 3 NQI 179 3 DNT 182 3 DNT 182 3 DNT 179 3 DNT 180 3 DNT 181 3 DNT 179 3 DNT 182 3 DNT 182 3 DNT 79 3

NQI 181 3 DNT 181 3 DNT 182 3 DNT 181 3 DNT 183 3 DNT 180 3 DNT 182 3 DNT 182 3 DNT 182 3 DNT 110 3 NQI 180 3 DNT 182 3 DNT 182 3 DNT 96 P 1 NQI 182 P 1 DNT 180 P 1 DNT 115 P 1 NQI 181 P 1 DNT 110 3 NQI 182 P 1 DNT 179 P 1 DNT 107 3 NQI 181 P 1 DNT

%TW LOCATION EXT LTS

+0.02 UTE LTS

+0.00 UTE LTS

+0.00 UTE LTS

+0.06 UTE LTS

+0.13 UTE LTS

+0.04 UTE LTS

-0.02 UTE LTS

-0.08 UTE LTS

-0.02 UTE 010

+27.94 UTE 010

+27.45 UTE 010

+26.86 UTE LTE

+10.73 014 LTE

+10.97 014 LTE

+11.05 014 011

+7.41 014 UTS

+0.00 UTE 003

-0.69 UTE 007

-0.87 UTE UTS

+0.00 UTE UTS

+0.00 UTE UTS

-0.02 UTE UTS

+0.02 UTE UTS

+0.07 UTE 012

+16.82 UTE UTS

+0.02 UTE UTS

+0.05 UTE 015

+9.27 UTE LTS

-0.07 UTE LTS

-0.04 UTE LTS

+0.04 UTE LTS

+0.13 UTE LTS

+0.00 UTE LTS

+0.04 UTE LTS

+0.04 UTE LTS

+0.07 UTE LTS

+0.09 UTE LTS

+0.04 UTE LTS

+0.04 UTE LTS

-0.18 UTE LTS

-0.07 UTE 009

+25.06 UTE LTE

+10.72 014 LTE

+9.28 014 LTE

+12.66 014 LTE

+8.97 014 LTE

+11.61 014 LTE

+10.60 014 LTE

+10.47 014 LTE

+10.77 015 LTE

+7.74 015 009

+11.47 014 LTE

+10.18 014 LTE

+7.20 014 LTE

+10.66 014 LTE

+11.21 014 LTE

+10.15 014 LTE

+10.85 014 LTE

+12.28 014 LTE

+10.68 014 LTE

+7.80 014 011

+36.32 014 LTE

+11.08 014 LTE

+7.91 014 LTE

+11.10 014 004

-0.77 014 UTS

-0.02 UTE UTS

+0.00 UTE 004

-0.71 UTE UTS

+0.02 UTE 004

+6.13 UTE UTS

+0.00 UTE UTS

+0.00 UTE 011

+14.13 UTE UTS

+0.00 UTE EXT LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTIL 1 UTIL 2 CAL 4 118 118 118 118 118 118 118 118 118 118 118 118 135 134 134 135 120 121 121 120 132 133 133 2

2 2

2 2

3 2

3 2

34 35 34 117 34 34 117 34 34 34 135 134 135 135 134 134 135 134 134 135 135 135 134 134 134 135 134 134 134 135 135 135 134 135 133 133 133 133 133 132 133 133 133 LEG OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET PROBE 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 5lOUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:26:28 Component: S/G B Page 19 of 30 ATTACHMENT #2 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 79 79 79 79 79 79 79 79 79 79 79 79 79 79 79 79 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 81 81 81 81 81 81 81 81 81 81 81 81 81 81 81 81 TUBE 52 55 56 57 58 59 60 64 68 69 70 71 78 80 82 84 85 111 1

2 14 17 23 35 46 52 72 73 74 85 86 87 88 89 7

8 48 62 63 71 72 73 74 86 87 88 89 90 109 123 130 2

18 23 29 36 37 44 62 66 71 72 73 74 86 88 109 VOLTS 7.35 7.37 6.61 6.00 6.26 6.04 7.74 7.96 12.00 12.60 14.76 6.92 8.39 6.88 8.89 8.85 6.92 0.47 21.68 18.64

0. 68 6.49 0.50 0.40 0.24 0.39 4.23 18.29
0. 62 10.33 6.04 18.33 7.11 6.19 12.57 6.99 0.43 0.30 1.78 11.16 6.71 32.26 13.39 29.81 4.08 7.75 10.31 20.79 6.01 9.36 6.54 14.92 6.80 1.36 1.07 0.61 0.48 0.64 0.51 0.68 0.54 0.32 0.51 0.27 29.24 7.04 231.50 102.40 9.01 10.19 6.25 9.01
6. 61 9.15 0.43 DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 182 179 183 185 185 185 186 187 188 181 184 175 187 184 185 184 184 94 181 182 43 180 66 66 104 96 17 188 115 178 177 186 183 186 187 184 98 70 81 181 178 181 182 182 77 192 180 185 185 184 181 187 186 104 104 110 90 76 103 110 111 113 78 80 181 179 19 16 185 187 178 190 183 186 90 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 NQI DNT DNT 1 NQI 1 DNT ADI NQI NQI NQI 1 NQI 1 DNT NQI 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT NQI NQI ADI DNT DNT DNT DNT DNT ADI 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 NQI TWD 22 1 NQI 1 NQI 1 NQI NQI 1 NQI 1 NQI NQI 1 NQI 1 NQI DNT DNT 1 BLG 1 BLG 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 NQI UTS UTS UTS UTS UTS UTS UTS UTS LTS LTS LTS LTS LTS LTS LTS LTS LTS 014 LTE LTE 007 UTS 015 LTS 011 010 UTS LTS 006 LTS LTS LTS LTS LTS LTS LTS 010 013 014 UTS LTE LTE UTS LTE 005 LTS LTS LTS LTS LTS LTS LTS LTS 015 014 008 012 014 010 010 010 010 010 010 LTE UTS UTS LTS LTS LTS LTS LTS LTS LTS 015

+0.00

+0.02

+0.08

+0. 10

+0.04

+0.08

+0.04

+0.05

-0. 09

+0.02

+0.07

+0.14

+0.00

+0.00

+0.04

-0. 11

-0.13

+0.99

+11.59

+10. 30

+0.66

+0.00

+29. 75

+22. 39

+26. 39

+20. 51

+21. 80

+0.00

+35. 06

+0.07

+0. 00

+0. 04

+0. 13

-0.06

-0.02

-0.09

+33. 30

+20.34

+11.11

+16.98

+18. 50

+16.90

+16.32

+16.88

+30.99

-0.04

-0.04

+0.02

+0.07

+0.07

+0.02

+0.00

-0.05

-0.60

+1.74

-0.56

+0.48

-0.93

+16.04

-0.80

-0.72

+19. 58

-0.77

-0.76

+17.00

+17.11

-0.07

-0.02

-0.09

-0.04

+0.07

+0.09

+0.09

+0.00

+0.07 UTE LTE UTE LTE LTE UTE LTE UTE LTE UTE LTE UTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE 014 LTE 014 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE 014 LTE 014 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE 014 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE 133 133 5

5 5

5 2

2 2

3 2

3 34 34 34 34 35 34 135 134 133 133 133 132 132 133 133 2

3 3

3 34 117 34 117 34 134 135 133 2

2 2

3 3

3 2

3 2

27 117 27 117 34 35 35 35 134 132 133 133 132 133 133 132 2

2 2

2 3

2 3

2 27 27 27 OUTLET OUTLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:26:28 Component: S/G B Page 20 of 30 ATTACHMENT #2 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 83 83 83 83 83 83 83 83 83 83 83 83 83 83 83 83 83 83 83 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 TUBE VOLTS 1

0.78 5

7.28 1.61 10 0.41 13 0.46 17 0.60 29 0.62 33 0.42 47 1.11 53 0.58 62 8.93 20.41 63 13.55 21.63 64 0.92 70 14.13 71 7.18 72 6.30 76 0.27 85 8.95 86 6.00 87 6.53 88 8.31 92 6.00 98 0.31 106 7.39 0.88 110 0.30 125 7.99 12.54 0.56 128 0.40 4

0.61 11 0.54 12 0.61 18 0.32 19 0.47 23 0.67 31 0.68 66 7.36 0.65 70 6.22 7.68 71 5.92 10.73 72 14.30 79 0.32 85 7.16 87 8.85 89 10.22 90 10.41 94 11.05 128 0.35 0.42 131 0.38 12 0.25 37 0.41 38 0.28 56 0.48 1.99 66 6.82 68 10.36 69 9.82 70 15.76 71 21.81 72 19.56 0.65 74 0.94 88 9.41 89 9.72 92 7.13 93 9.26 114 0.43 118 8.52 120 0.87 DEG 42 188 122 106 111 90 76 65 83 92 180 182 181 179 97 185 169 180 105 187 183 182 184 191 96 157 89 90 179 185 113 82 94 47 70 78 105 49 121 190 110 189 190 117 184 183 110 184 183 186 184 189 108 105 106 85 101 65 111 81 192 189 183 187 181 183 136 108 187 182 191 189 85 191 69 CHN P=1 P 1 3

3 3

3 P1 P 1 6

3 3

3 3

3 3

P 1 P 1 P 1 3

P 1 P 1 P 1 P 1 P1 3

3 P 1 3

3 3

3 P 1 3

P 1 P 1 P 1 P 1 P 1 P1I 31 3

3 P 1 4

P 1 P 1 3

P1 P 1 P 1 P 1 P 1 3

3 3

3 3

3 3

6 P 1 P 1 P 1 P 1 P 1 P 1 P 1 3

P 1 P 1 P 1 P 1 P 1 3

3 IND %TW LOCATION EXT EXT NQI 004

+0.80 014 LTE DNT 010

-0.51 014 LTE NQI 010

+5.67 TO+7.99 014 LTE NQI 007

+7.57 UTE LTE NQI 002

+20.73 UTE LTE NQI 010

+17.89 UTE LTE NQI 010

-0.84 UTE LTE NQI 010

-0.77 UTE LTE ADI 012

+26.19 UTE LTE NQI 014

+2.16 UTE LTE DNT UTS

+16.45 UTE LTE DNT LTE

+16.92 UTE LTE DNT UTS

+17.03 UTE LTE DNT LTE

+17.28 UTE LTE NQI 001

+1.11 UTE LTE DNT LTS

+0.00 UTE LTE DNT LTS

+0.00 UTE LTE DNT LTS

+0.07 UTE LTE NQI 006

+32.17 UTE LTE DNT LTS

+0.13 UTE LTE DNT LTS

+0.04 UTE LTE DNT LTS

-0.02 UTE LTE DNT LTS

+0.02 UTE LTE DNT LTS

-0.07 UTE LTE NQI 015

+27.32 UTE LTE DNT 013

+33.12 UTE LTE NQI 014

-0.86 UTE LTE NQI 010

+34.37 UTE LTE DNT UTS

+3.51 UTE LTE DNT UTS

+3.25 UTE LTE NQI 014

+1.54 UTE LTE NQI 010

+0.94 UTE LTE NQI 010

-0.82 TO+11.80 014 LTE NQI 010

-0.55 UTE LTE NQI 010

-0.61 UTE LTE NQI 008

+0.45 UTE LTE NQI 010

-0.55 UTE LTE NQI 010

-0.80 UTE LTE NQI 010

+0.53 UTE LTE DNT LTS

-0.04 UTE LTE NQI 001

+1.17 UTE LTE DNT 005

+21.11 UTE LTE DNT LTS

-0.04 UTE LTE TWD 12 008

+23.81 UTE LTE DNT LTS

-0.07 UTE LTE DNT LTS

+0.00 UTE LTE NQI 009

+24.03 UTE LTE DNT LTS

+0.07 UTE LTE DNT LTS

+0.04 UTE LTE DNT LTS

+0.00 UTE LTE DNT LTS

-0.11 UTE LTE DNT LTS

-0.13 UTE LTE NQI 012

+20.71 UTE LTE NQI 012

+18.88 UTE LTE NQI 011

+1.25 UTE LTE NQI 003

+27.54 UTE LTE NQI 011

+36.13 UTE LTE NQI 011

+23.04 UTE LTE NQI 009

+25.42 UTE LTE ADI 004

+17.12 UTE LTE DNT LTS

-0.04 UTE LTE DNT LTS

-0.04 UTE LTE DNT LTS

-0.09 UTE LTE DNT LTS

-0.04 UTE LTE DNT LTS

-0.02 UTE LTE DNT LTS

+0.02 UTE LTE NQI 013

+0.60 UTE LTE NQI 013

+25.46 UTE LTE DNT LTS

+0.00 UTE LTE DNT LTS

-0.09 UTE LTE DNT LTS

-0.11 UTE LTE DNT LTS

-0.15 UTE LTE TWD 23 014

+0.92 UTE LTE DNT LTE

+7.36 UTE LTE NQI LTS

+6.19 UTE LTE UTIL 1 UTIL 2 CAL #

135 134 134 132 133 133 133 133 133 133 3

3 2

2 3

2 3

2 27 117 27 28 27 27 27 27 27 27 27 27 27 28 138 133 132 137 136 136 136 2

2 2

2 3

3 2

27 27 27 27 28 27 27 27 28 137 136 137 136 136 2

2 3

2 3

2 2

2 27 28 27 28 27 27 27 LEG PROBE OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:26:29 Component: S/G B Page 21 of 30 ATTACHMENT #2 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW 84 84 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 86 86 86 86 86 86 86 86 86 86 86 86 86 86 87 87 87 87 87 87 87 87 87 87 87 88 88 88 88 88 88 88 88 88 88 88 88 88 88 89 89 89 89 89 89 89 89 89 89 89 89 89 89 TUBE VOLTS 129 1.75 130 1.76 8

0.39 27 1.03 60 6.35 62 7.51 7.57 63 9.34 64 8.37 65 6.46 66 6.40 67 11.62 68 11.56 69 24.02 70 28.76 71 24.43 88 7.56 102 0.45 109 0.70 117 0.27 2

0.41 3

0.98 63 12.71 64 24.27 65 10.72 66 6.21 68 9.57 69 9.81 70 25.04 71 18.49 87 7.52 102 0.27 120 1.18 128 0.49 3

0.98 40 0.43 57 7.49 60 7.45 61 7.60 62 17.88 63 14.57 64 15.84 70 2.39 84 6.95 86 12.42 24 0.41 27 0.35 58 6.60 59 13.20 60 14.68 61 23.74 62 22.30 63 13.55 64 6.28 71 0.58 84 7.19 86 7.79 95 6.39 96 10.02 3

1.20 0.73 5

0.33 58 8.53 59 21.40 60 22.21 61 8.86 66 235.20 107.30 69 0.34 71 0.47 81 11.32 83 6.42 85 6.54 95 10.67 96 9.73 DEG CHN 89 P 1 81 P 1 104 3 38 P 1 185 P 1 188 P 1 177 P 1 187 P 1 182 P 1 188 P 1 177 P 1 186 P 1 181 P 1 184 P 1 181 P 1 186 P 1 188 P 1 84 3

100 3 109 3 90 3

100 3 186 P 1 184 P 1 179 P 1 183 P 1 183 P 1 176 P 1 185 P 1 180 P 1 183 P 1 87 3

58 P 1 78 P 1 59 P 1 92 3

182 P 1 190 P 1 184 P 1 186 P 1 178 P 1 185 P 1 114 3 182 P 1 185 P 1 114 3 101 3 176 P 1 184 P 1 183 P 1 185 P 1 186 P 1 179 P 1 180 P 1 112 3 183 P 1 185 P 1 184 P 1 189 P 1 159 3 62 3

92 P 1 182 P 1 187 P 1 186 P 1 177 P 1 19 P 1 18 P 1 91 3

84 3

186 3 184 P 1 190 3 187 P 1 193 P 1 IND %TW LOCATION EXT TWD 52 013

+0.60 UTE TWD 35 013

+1.24 UTE NQI 012

+8.77 UTE NQI 010

+0.61 LTE DNT LTS

-0.09 UTE DNT LTS

-0.09 UTS DNT LTS

-0.09 LTE DNT LTS

-0.09 UTE DNT LTS

-0.09 UTE DNT LTS

-0.09 UTE DNT LTS

-0.07 UTE DNT LTS

-0.04 UTE DNT LTS

-0.02 UTE DNT LTS

+0.02 UTE DNT LTS

+0.02 UTE DNT LTS

+0.04 UTE DNT LTS

-0.06 UTE NQI 006

+25.96 UTE NQI 002

+37.28 UTE NQI 014

+1.28 UTE NQI 010

+1.41 TO+17.43 015 NQI 010

+1.88 014 DNT LTS

-0.02 UTE DNT LTS

-0.07 UTE DNT LTS

-0.11 UTE DNT LTS

-0.04 UTE DNT LTS

+0.00 UTE DNT LTS

+0.05 UTE DNT LTS

+0.04 UTE DNT LTS

+0.07 UTE DNT LTS

+0.02 UTE NQI LTS

+34.03 UTE NQI 014

+0.75 UTE NQI 006

+0.69 UTE NQI 012

+0.72 014 NQI 007

+23.97 UTE DNT LTS

-0.13 UTE DNT LTS

+0.00 UTE DNT LTS

-0.04 UTE DNT LTS

+0.00 UTE DNT LTS

+0.05 UTE DNT LTS

+0.00 UTE NQI 012

+11.18 UTE DNT LTS

+0.07 UTE DNT LTS

+0.00 UTE NQI 010

+13.85 UTE NQI 014

+6.72 UTE DNT LTS

+0.00 UTE DNT LTS

+0.00 UTE DNT LTS

+0.00 UTE DNT LTS

-0.55 UTE DNT LTS

-0.55 UTE DNT LTS

+0.09 UTE DNT LTS

+0.00 UTE NQI 010

+19.49 UTE DNT LTS

+0.07 UTE DNT LTS

+0.07 UTE DNT LTS

-0.15 UTE DNT LTS

-0.13 UTE NQI 010

+1.34 014 NQI 009

+37.63 014 NQI 009

+0.60 UTE DNT LTS

+0.07 UTE DNT LTS

+0.13 UTE DNT LTS

+0.00 UTE DNT LTS

+0.07 UTE BLG LTS

-0.35 UTE BLG UTS

-0.04 UTE NQI 007

+14.76 UTE NQI 015

+37.77 UTE DNT 011

+20.55 UTE DNT LTS

+0.07 UTE DNT 002

+3.83 UTE DNT LTS

-0.15 UTE DNT LTS

-0.20 UTE EXT LTE LTE LTE UTE LTE LTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTIL 1 UTIL 2 CAL #

28 27 137 153 2

2 9

2 3

2 3

2 3

2 3

2 27 27 28 27 138 138 2

2 3

2 2

3 2

3 24 25 24 28 138 141 143 143 2

3 2

3 2

3 24 14 1 143 143 14 1 2

2 2

3 2

3 37 37 38 37 138 138 148 141 141 2

3 2

2 3

3 34 34 34 34 117 LEG OUTLET OUTLET OUTLET INLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET PROBE 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 50OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:26:29 Component: S/G B Page 22 of 30 ATTACHMENT #2 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW TUBE VOLTS 89 105 0.67 89 122 8.05 8.87 89 124 7.36 11.59 6.37 13.77 6.25 89 127 0.82 90 3

0.49 90 5

0.41 90 54 7.75 19.81 90 58 21.66 90 59 18.05 90 60 6.04 90 66 6.10 90 67 6.50 90 75 0.45 0.34 0.39 0.32 90 80 6.12 90 82 7.61 90 83 6.14 90 85 0.34 90 91 0.22 0.41 90 94 11.94 0.36 90 95 9.02 90 116 1.00 90 129 0.25 0.27 91 1

0.47 91 3

0.56 91 56 6.04 91 57 8.24 91 58 15.09 91 59 6.57 91 60 11.93 91 64 6.85 91 71 7.26 91 72 7.06 91 73 7.74 91 78 5.05 91 79 6.55 91 81 6.57 91 88 0.41 0.24 91 92 6.66 91 102 0.75 91 108 0.55 91 110 0.93 92 3

0.55 92 17 0.32 92 57 6.38 92 59 19.18 92 60 18.81 92 61 11.95 92 62 13.90 92 63 6.07 92 67 6.18 92 71 7.45 92 75 9.60 92 76 6.58 92 77 13.45 92 78 10.84 92 79 10.78 92 81 7.08 92 82 6.35 92 83 8.64 92 102 8.57 92 124 8.84 93 6

0.28 DEG 102 179 182 185 185 187 184 184 63 86 72 185 183 184 184 176 175 183 96 63 95 67 184 185 178 98 112 113 189 88 190 90 113 108 90 86 185 183 185 176 185 184 182 197 190 175 185 184 74 82 190 95 104 56 44 103 176 185 178 186 179 183 182 189 191 172 187 178 182 180 177 186 195 193 110 CHN 3

3 3

3 3

3 3

3 P 1 P 1 3

3 3

P 1 P 1 P 1 P 1 31 3

3 3

3 P 1 P 1 P1 3

3 3

P 1 3

P 1 P 1 3

3 3

3 P 1 P 1 P1 P 1 P 1 P 1 3

P 1 P 1 P 1 P 1 3

3 P 1 3

P 1 3

P1 P 1 P 1 3

P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 P 1 3

3 IND NQI DNT DNT DNT DNT DNT DNT DNT NQI NQI NQI DNT DNT DNT DNT DNT DNT DNT NQI NQI NQI NQI DNT DNT DNT NQI TWD NQI DNT NQI DNT NQI NQI NQI NQI NQI DNT DNT DNT DNT DNT DNT DNT DNT DNT NQI DNT DNT NQI NQI DNT NQI NQI NQI NQI NQI DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT NQI

%TW LOCATION EXT EXT 013

+4.48 UTE LTE UTS

+11.72 UTE LTE UTS

+10.55 UTE LTE UTS

+15.45 UTE LTE UTS

+21.42 UTE LTE UTS

+21.97 UTE LTE UTS

+22.39 UTE LTE UTS

+19.77 UTE LTE 014

+0.91 UTE LTE 010

+0.26 UTE LTE 009

+37.08 UTE LTE 005

+23.62 UTE LTE 005

+22.57 UTE LTE LTS

+0.04 UTE LTE LTS

+0.00 UTE LTE LTS

+0.14 UTE LTE LTS

+0.09 UTE LTE LTS

+0.07 UTE LTE 006

+16.93 UTE LTE 006

+37.58 UTE LTE 005

+32.45 UTE LTE 005

+31.30 UTE LTE LTS

+0.16 UTE LTE LTS

+0.02 UTE LTE LTS

+0.00 UTE LTE 002

+27.02 UTE LTE 6

015

+19.35 UTE LTE 015

+16.27 UTE LTE LTS

-0.33 UTE LTE 007

+14.74 UTE LTE LTS

-0.24 UTE LTE 014

+0.75 UTE LTE 014

+1.48 UTE LTE 014

+1.24 UTE LTE 010

+8.42 UTE LTE 014

+11.77 UTE LTE LTS

+0.02 UTE LTE LTS

+0.04 UTE LTE LTS

+0.00 UTE LTE LTS

+0.00 UTE LTE LTS

+0.00 UTE LTE LTS

+0.00 UTE LTE LTE

+7.05 UTE LTE LTS

+0.00 UTE LTE LTS

+0.15 UTE LTE LTS

-0.02 UTE LTE LTS

+0.11 UTE LTE LTS

+0.00 UTE LTE 012

+6.35 UTE LTE 009

+35.29 UTE LTE LTS

-0.18 UTE LTE 010

+28.27 UTE LTE 005

+6.83 UTE LTE 015

+0.39 UTE LTE 010

+0.65 UTE LTE 010

+3.16 UTE LTE LTS

+0.02 UTE LTE LTS

+0.00 UTE LTE LTS

+0.07 UTE LTE LTS

+0.00 UTE LTE LTS

+0.05 UTE LTE LTS

+0.07 UTE LTE LTS

+0.13 UTE LTE LTS

+0.00 UTE LTE LTS

+0.24 UTE LTE LTS

+0.07 UTE LTE LTS

+0.11 UTE LTE LTS

+0.11 UTE LTE LTS

+0.07 UTE LTE LTS

+0.04 UTE LTE LTS

+0.00 UTE LTE LTS

+0.02 UTE LTE LTE

+3.69 UTE LTE LTE

+5.68 UTE LTE 014

+1.18 UTE LTE UTIL 1 UTIL 2 CAL #

34 117 117 117 117 117 117 117 34 147 147 141 141 141 2

3 3

2 25 25 25 25 24 24 25 25 25 25 24 24 25 25 24 24 147 147 147 147 2

3 2

2 3

2 37 25 24 24 24 24 24 24 24 24 147 148 148 2

3 2

3 2

2 2

37 38 37 25 24 24 25 24 25 25 147 LEG PROBE OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL OUTLET 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:26:29 Component: S/G B Page 23 of 30 ATTACHMENT #2 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW 93 93 93 93 93 93 93 93 93 93 93 93 93 93 93 93 93 93 93 93 93 94 94 94 94 94 94 94 94 94 94 94 94 94 94 94 94 94 94 94 94 94 94 95 95 95 95 95 95 95 95 95 95 95 95 95 95 95 96 96 96 96 96 96 96 96 TUBE VOLTS 21 0.33 0.37 28 0.25 0.19 48 1.26 54 9.32 55 0.30 0.18 6.19 57 16.62 58 12.84 59 12.95 60 9.53 61 10.41 65 6.04 71 6.10 72 12.92 73 21.88 74 8.96 76 12.17 77 6.89 80 7.76 81 11.38 109 0.85 0.60 118 0.58 2

9.76 3

0.34 19 0.35 54 6.82 58 6.13 60 7.64 61 11.45 62 6.29 66 0.39 71 9.13 73 7.68 74 13.48 75 38.42 76 17.49 0.27 77 12.15 78 7.27 79 9.21 80 9.11 81 10.05 82 11.16 83 17.45 103 0.28 2

0.60 55 6.80 0.30 61 6.13 67 6.89 69 6.63 73 19.77 74 37.12 75 16.42 77 11.06 78 14.98 79 8.65 0.32 80 7.83 81 17.50 82 7.15 128 0.40 2

0.86 44 2.41 60 7.97 62 0.26 7.20 64 8.40 65 9.15 66 7.22 67 9.16 DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 84 87 86 86 17 177 91 100 183 186 179 186 176 183 183 190 190 187 173 178 187 178 186 83 116 99 187 127 73 179 177 188 187 176 80 187 187 179 187 178 71 186 177 189 176 187 180 186 110 133 177 78 181 183 184 186 186 177 190 181 192 83 180 187 178 115 105 26 180 56 174 175 186 173 185 3

3 NQI NQI NQI NQI NQI 1 DNT NQI NQI 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 NQI NQI 1 NQI 1 DNT 1 NQI 1 NQI 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 NQI DNT 1 DNT 1 DNT 1 DNT 1 DNT NQI 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT NQI 1 NQI 1 DNT NQI 1 DNT 1 DNT DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT NQI 1 DNT 1 DNT 1 DNT 1 NQI 1 NQI 1 NQI 1 DNT NQI 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 007 006 013 012 008 LTS 008 008 LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS 014 014 014 010 010 014 LTS LTS LTS LTS LTS UTS 003 LTS LTS LTS LTS 015 LTS LTS LTS LTS LTS LTS LTS 009 010 LTS LTS LTS LTS 013 LTS LTS LTS LTS LTS LTS 013 LTS LTS LTS 008 010 010 LTS 006 LTS LTS LTS LTS LTS

+17.65

+35.47

+17. 85

+8.78

+19. 36

-0.02

+12.45

+32.59

-0.30

+0. 00

+0. 09

+0. 00

+0.05

+0. 00

+0. 00

+0.00

+0.22

+0.07

+0.07

+0.00

+0.09

+0.00

-0.02

+0.78

+1.07

+0.91

-0.11

+0.63

+0.96

-0.17

+0.08

+0.00

+0.00

+0.00

+20. 82

+17. 28

-0.06

-0.35

+0.07

+0.04

+25. 38

+0.13

+0. 09

+0.11

+0.02

+0.15

-0.02

-0.02

+35.04

+0. 54

+0.02

+14.49

-0.02

+0.00

+19.81

+0. 00

+0.07

+0.04

+0.13

+0.07

+0.07

+18.84

+0.07

-0.02

-0.07

-0.46

+0.52

-0.95

+0. 00

+3.46

+0.00

+0.00

+0.04

+0.11

+0.09 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 147 147 148 148 148 148 147 147 147 2

3 2

3 2

2 2

37 37 38 25 24 25 24 23 23 22 147 148 147 148 148 2

2 3

3 2

2 3

37 23 23 22 23 22 23 22 23 22 23 147 148 148 3

2 2

2 37 38 22 23 22 22 23 22 23 22 147 147 148 151 151 151 37 38 37 OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:26:29 Component: S/G B Page 24 of 30 ATTACHMENT #2 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW 96 96 96 96 96 96 96 96 96 96 96 96 96 97 97 97 97 97 97 97 97 97 97 97 97 97 97 97 97 97 97 97 97 97 97 98 98 98 98 98 98 98 98 98 98 98 98 98 98 98 98 98 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 TUBE VOLTS 68 10.09 69 8.36 71 6.31 72 6.86 73 12.29 74 6.58 75 10.66 7.07 76 11.50 78 11.08 79 6.13 80 7.22 122 0.48 127 0.62 2

0.54 25 0.38 56 10.25 57 7.88 61 0.31 65 9.82 66 6.10 67 9.97 68 7.47 69 10.07 71 7.55 72 6.94 73 8.52 74 7.83 75 12.82 76 12.94 77 10.85 78 0.27 10.77 79 6.25 81 0.24 100 0.26 112 0.30 12 0.92 56 7.54 57 10.55 58 8.71 59 9.29 64 7.73 65 8.00 66 0.33 67 9.35 69 6.81 70 6.66 71 7.66 73 11.48 75 7.98 76 17.02 77 11.01 78 8.66 6

0.32 41 0.49 58 13.38 59 6.81 63 7.52 64 10.21 65 6.08 67 0.26 0.48 0.48 0.61 0.34 0.70 68 8.27 69 7.36 71 6.57 72 6.98 73 7.15 75 7.02 77 9.04 83 0.28 DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 175 183 184 175 183 174 184 189 182 182 182 186 104 92 115 98 187 178 103 184 174 185 174 185 186 177 187 180 186 182 182 97 181 186 101 112 84 88 181 180 182 176 176 185 117 183 179 175 185 182 178 189 182 184 99 85 184 178 179 184 182 92 112 106 113 107 110 174 183 184 179 184 187 186 90 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT DNT 1 DNT 1 DNT 1 DNT 1 DNT NQI 1 NQI 1 NQI NQI 1 DNT 1 DNT NQI 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT NQI 1 DNT 1 DNT NQI NQI NQI NQI 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT NQI 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT NQI 1 NQI 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT NQI NQI NQI NQI NQI NQI 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT 1 DNT NQI LTS LTS LTS LTS LTS LTS LTS UTS LTS LTS LTS LTS 015 008 010 008 LTS LTS 014 LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS LTS 013 LTS LTS 001 007 014 014 LTS LTS LTS LTS LTS LTS 011 LTS LTS LTS LTS LTS LTS LTS LTS LTS 012 013 LTS LTS LTS LTS LTS 015 015 015 015 015 015 LTS LTS LTS LTS LTS LTS LTS 009

+0.09

+0. 11

+0.09

+0.04

+0.07

+0.07

+0. 18

+20. 00

+0.07

+0.07

+0.02

+0.00

+31.33

-0.42

+0.59

+11.37

-0. 19

+0.00

+15.84

+0.04

+0.00

+0.09

+0.11

+0.09

+0.07

+0.04

+0.02

+0.02

+0.13

+0.02

+0.04

+11. 37

+0.02

-0.02

+10.46

+18.81

+4.80

+1.28

+0.00

-0.02

-0.39

+0.00

+0.00

+0.00

+17.78

+0.00

+0.00

+0.09

+0.09

+0.00

+0.00

+0.00

+0.00

+0.00

+35.32

+0.18

+0.02

+0.00

+0.00

+0.02

+0.00

+34.70

+34.06

+33.82

+33.49

+29.83

+27.63

+0.04

+0.02

+0.00

+0.04

-0.02

-0.04

+0.00

+2.53 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 38 37 37 38 37 38 37 37 17 17 17 17 22 22 148 148 150 151 151 37 38 37 38 37 37 38 37 38 37 17 17 17 17 17 17 17 16 151 149 149 150 151 151 37 38 37 37 38 37 37 38 16 17 16 151 149 150 151 151 37 37 37 37 37 37 37 37 38 37 37 38 37 16 16 16 OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 5lOUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:26:29 Component: S/G B Page 25 of 30 ATTACHMENT #2 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW TUBE VOLTS 99 86 0.25 99 91 0.14 99 101 6.63 99 126 0.90 100 43 0.55 100 59 6.07 100 60 8.65 100 61 7.03 100 63 7.88 100 64 9.15 100 66 6.06 100 68 6.92 100 69 0.40 100 70 7.55 100 71 8.43 100 72 8.22 100 74 8.42 100 102 6.90 100 120 0.28 0.35 100 125 0.50 101 1 0.42 0.40 101 4 0.79 101 44 0.45 101 60 6.24 101 63 8.24 101 66 0.44 101 69 6.47 101 71 8.83 101 73 6.64 101 120 1.27 101 122 0.65 102 2 0.59 102 20 0.41 102 39 0.38 102 75 7.65 102 103 11.80 102 121 0.73 102 123 0.29 0.41 103 24 0.52 0.57 103 60 0.22 103 75 7.70 104 1 0.28 104 40 0.35 104 57 0.47 104 89 0.49 104 93 3.66 105 53 0.54 105 65 10.94 105 118 0.24 105 121 0.66 3.83 105 122 2.94 10.65 106 4 1.00 106 58 6.19 106 63 0.57 0.53 106 98 0.74 106 119 0.35 107 20 0.45 107 46 0.92 107 84 0.37 107 102 10.93 107 113 0.56 108 85 0.41 108 86 0.49 108 94 0.21 108 115 0.41 1.23 108 116 0.32 108 118 0.39 DEG 75 85 185 122 76 173 181 177 176 183 183 182 82 185 180 183 186 4

88 90 123 107 110 97 82 181 187 104 186 188 182 123 74 119 93 82 184 182 134 111 92 91 90 92 186 112 105 132 107 87 111 192 94 92 17 104 19 102 178 88 88 72 95 102 76 89 184 85 97 141 98 106 57 106 61 CHN 3

3 3

P1I P1I P1 P 1 P 1 P 1 P 1 P 1 P 1 3

P 1 P 1 P1 P 1 3

3 3

3 3

P 1 P 1 P 1 2 1 3

P 1 3

P 1 P1 3

P 1 3

P 1 P1 P 1 3

P1 3

P 1 3

3 3

3 33 1 3

6 P 1 3

3 P1I P1I P1I P1I P 1 P 1 3

3 6

3 3

P1 3

3 3

3 P 1 3

3 P 1 P 1 IND N=I NQI DNT NQI NQI DNT DNT DNT DNT DNT DNT DNT NQI DNT DNT DNT DNT DNT NQI NQI NQI NQI NQI NQI NQI DNT DNT NQI DNT DNT DNT NQI NQI NQI NQI NQI DNT DNT NQI NQI NQI NQI NQI NQI DNT NQI NQI NQI NQI ADI NQI DNT NQI NQI NQI NQI BLG NQI DNT NQI NQI ADI NQI NQI NQI NQI DNT NQI TWD NQI NQI TWD NQI NQI NQI

%TW LOCATION 012

+8.02 008

+19.17 008

+16.05 008

-0.64 013

+0.73 LTS

+0.00 LTS

+0.00 LTS

-0.20 LTS

-0.16 LTS

-0.02 LTS

-0.04 LTS

+0.04 006

+12.37 LTS

+0.11 LTS

+0.04 LTS

-0.02 LTS

+0.00 UTS

+14.38 011

+34.97 010

+5.51 008

-0.70 010

+7.13 010

+6.67 009

-0.23 014

+0.43 LTS

+0.00 LTS

-0.11 013

+15.82 LTS

+0.00 LTS

-0.04 LTS

+0.00 014

+33.62 UTS

+20.31 010

+0.51 013

+21.57 014

-0.38 LTS

+0.00 UTS

+19.67 009

-0.65 012

+5.94 008

-0.70 013

+5.61 012

+15.84 014

+6.71 LTS

-0.13 010

+11.09 009

+20.49 005

+26.27 008

+21.23 LTS

+20.63 TO+29.76 UTS

+19.45 LTS

+1.90 014

+1.44 008

-0.75 015

+0.97 015

-0.78 UTS

-0.20 009

-0.60 LTS

+0.00 009

+9.26 009

+8.24 015

+23.78 003

+24.15 007

+33.46 UTS

+16.14 011

+1.53 013

+13.77 008

+3.75 32 008

+24.35 004

-0.79 010

+5.56 13 001

+9.23 010

+0.81 011

+20.28 010

+0.58 EXT EXT UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE LTE UTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE LTE UTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTIL 1 UTIL 2 CAL 17 16 16 16 149 153 150 151 151 37 37 37 38 37 38 37 14 14 16 16 17 149 149 149 149 151 37 38 37 37 14 15 15 149 146 149 14 14 14 15 15 144 144 151 14 140 146 147 14 14 146 37 15 14 14 15 15 130 153 37 37 15 15 130 130 15 15 14 10 11 11 10 10 11 11 LEG OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET PROBE 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 5lOUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:26:30 Component: S/G B Page 26 of 30 ATTACHMENT #2 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW 109 109 109 109 109 109 109 109 109 109 110 110 110 110 110 110 110 111 111 111 111 111 111 112 112 112 112 112 112 112 113 113 113 113 113 113 114 114 114 114 114 114 114 115 115 115 115 115 115 116 116 116 116 117 117 117 117 117 117 117 117 118 118 TUBE VOLTS 2

0.18 19 0.50 29 0.41 31 0.51 49 0.28 0.42 61 0.39 65 0.30 0.33 69 0.42 99 0.64 106 0.25 29 0.35 0.35 60 6.28 61 14.77 62 9.16 90 21.22 106 0.44 3

0.38 25 0.34 41 0.34 60 8.47 61 6.21 72 6.63 110 0.55 16 0.38 20 5.66 59 0.55 104 0.83 110 0.64 115 1.01 116 0.47 20 0.44 22 16.62 36 0.68 85 0.31 93 0.42 99 0.34 1

1.01 5

0.50 11 0.72 15 0.47 18 0.31 0.91 0.68 0.45 0.38 0.35 67 0.40 114 0.52 65 0.43 97 0.80 98 0.49 107 0.34 110 1.05 111 3.08 0.51 49 0.49 82 0.30 107 0.23 108 0.64 3

0.60 0.30 19 0.65 56 0.57 76 0.28 83 3.84 3.95 90 0.38 106 0.55 108 0.23 3

0.53 0.51 56 0.66 DEG CHN IND %TW LOCATION 86 P 1 NQI 015

-0.40 94 3

NQI 010

+28.30 101 3 NQI 009

+6.33 89 P 1 NQI 014

-0.54 86 3

NQI 011

+17.77 79 3

NQI 007

+18.09 77 3

NQI 009

+17.13 98 3

TWD 30 015

+33.50 69 3

NQI 015

+37.25 107 3 TWD 11 015

+16.89 46 3

NQI 004

+27.27 103 3 NQI 010

+29.50 80 3

NQI 011

+14.92 95 3

NQI 011

+16.75 185 P 1 DNT LTS

-0.22 189 P 1 DNT LTS

-0.15 185 P 1 DNT LTS

-0.22 174 3 DNT 001

+9.79 69 3

NQI 013

+8.83 103 P 1 NQI 008

+0.44 88 3

NQI 011

+34.26 88 3

NQI 015

+31.97 186 P 1 DNT LTS

-0.24 187 P 1 DNT LTS

-0.24 189 3 DNT UTS

+17.33 126 P 1 NQI 009

-0.79 74 3

NQI 003

+8.86 82 6

ADI LTS

+19.71 TO+28.73 81 3

NQI 012

+14.67 83 3

NQI LTE

+16.94 114 P 1 NQI 009

-0.79 72 P 1 NQI 010

+0.66 103 P 1 NQI 008

-0.55 89 3

NQI 010

+24.47 181 3 DNT LTS

+6.58 135 3 NQI LTS

+22.11 TO+29.02 90 3

NQI 008

+18.46 88 3

NQI 009

+11.64 62 P 1 NQI 015

-0.26 42 P 1 NQI 007

-0.80 105 3 NQI 008

+16.84 113 P 1 NQI 014

+0.78 79 3

NQI 015

+20.79 97 3

NQI 005

+12.62 71 3

NQI 006

+19.56 86 3

NQI 007

+26.66 74 3

NQI 008

+4.38 95 3

NQI 008

+24.28 101 3 NQI 009

+7.16 95 3

NQI 007

+13.56 83 P 1 NQI 010

+0.69 73 3

NQI 014

+2.45 93 3

NQI 014

+1.07 88 3

NQI 013

+12.83 108 P 1 NQI 009

-0.69 88 P 1 NQI 009

-0.71 98 P 1 NQI 008

-0.60 118 P 1 NQI 008

+0.39 59 P 1 NQI 012

+0.28 96 3

NQI 008

+34.02 90 P 1 NQI 008

+0.23 100 3 NQI 014

+32.21 93 P 1 NQI 009

+0.47 88 3

NQI 002

+2.50 98 3

NQI 004

+5.04 93 3

NQI 015

+24.85 92 3

NQI 007

+24.47 35 6

ADI 009

+7.76 26 6

ADI 009

+3.47 74 P 1 NQI 014

+0.97 75 P 1 NQI 010

+0.65 103 P 1 NQI 008

+0.30 106 P 1 NQI 009

+0.52 97 P 1 NQI 009

+0.54 130 P 1 NQI 004

-0.82 EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 121 120 120 120 120 120 10 10 10 10 10 11 73 73 43 113 43 43 53 74 74 74 43 43 113 54 74 74 74 54 54 53 54 74 74 74 45 45 54 77 78 78 78 77 77 77 77 77 77 45 54 45 54 53 54 53 54 54 78 49 54 53 78 78 78 49 49 50 50 53 54 54 82 86 50 OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 510UL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL IDOK

Framatome ANP Inc.

12/05/01 14:26:30 Customer Name: Oconee Unit 3 Component: S/G B Page 27 of 30 ATTACHMENT #2 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMi ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL

  • LEG PROBE 118 79 0.32 113 3 NQI 008

+25.97 UTE LTE 49 OUTLET 51OUL 118 86 0.92 105 P 1 NQI 004

-0.76 UTE LTE 50 OUTLET 51OUL 118 99 1.09 114 3 NQI 014

+26.96 UTE LTE 54 OUTLET 51OUL 118 102 0.54 109 3 NQI 015

+44.35 UTE LTE 53 OUTLET 51OUL 0.55 57 P 1 NQI 014

+0.95 UTE LTE 53 OUTLET 51OUL 118 106 0.42 94 3

NQI 014

+16.42 UTE LTE 53 OUTLET 51OUL 0.93 68 P 1 NQI 004

-0.75 UTE LTE 53 OUTLET 51OUL 118 107 0.74 114 3 NQI 010

+5.78 UTE LTE 54 OUTLET 51OUL 119 88 0.30 98 P 1 NQI 014

+0.31 UTE LTE 49 OUTLET 51OUL 119 90 0.44 122 3 NQI 003

+34.15 UTE LTE 49 OUTLET 51OUL 119 98 0.70 88 3

NQI 001

+27.86 UTE LTE 54 OUTLET 51OUL 119 106 1.91 97 P 1 NQI 008

-0.53 UTE LTE 54 OUTLET 51OUL 120 1 1.18 119 3 NQI 015

+18.26 UTE LTE 85 OUTLET 51OUL 120 78 0.54 83 P 1 NQI 013

+0.58 UTE LTE 49 OUTLET 51OUL 120 105 1.81 102 P 1 NQI 008

-0.68 UTE LTE 53 OUTLET 51OUL 0.59 80 P 1 NQI 010

-0.22 UTE LTE 53 OUTLET 51OUL 120 107 0.40 79 3

NQI 008

+3.54 UTE LTE 54 OUTLET 51OUL 0.54 39 P 2 NQI 015

-0.46 UTE LTE 54 OUTLET 51OUL 121 1 0.50 101 3 NQI 013

+2.17 UTE LTE 85 OUTLET 51OUL 121 78 0.28 88 3

NQI 015

+36.78 UTE LTE 50 OUTLET 51OUL 122 3 0.50 90 P 1 NQI 009

-0.79 UTE LTE 86 OUTLET 51OUL 122 7 0.48 78 P 1 NQI 008

+0.00 UTE LTE 86 OUTLET 51OUL 122 47 0.39 66 3

NQI 009

+6.11 UTE LTE 86 OUTLET 51OUL 122 51 0.24 92 3

NQI 011

+19.22 UTE LTE 86 OUTLET 51OUL 122 58 0.82 112 3 NQI 013

+8.87 UTE LTE 49 OUTLET 51OUL 122 82 0.42 90 3

NQI 014

+23.44 UTE LTE 49 OUTLET 51OUL 122 84 0.50 82 3

NQI 011

+29.46 UTE LTE 49 OUTLET 51OUL 0.29 98 3

NQI 009

+21.49 UTE LTE 49 OUTLET 51OUL 0.32 121 3 NQI 008

+16.77 UTE LTE 49 OUTLET 51OUL 0.32 86 3

NQI 008

+18.33 UTE LTE 49 OUTLET 51OUL 0.68 109 3 NQI 007

+10.44 UTE LTE 49 OUTLET 51OUL 0.46 99 3

NQI 005

+18.64 UTE LTE 49 OUTLET 51OUL 0.38 100 3 NQI 005

+8.51 UTE LTE 49 OUTLET 51OUL 122 103 2.07 95 P 1 NQI 008

-0.64 UTE LTE 53 OUTLET 51OUL 122 104 0.70 100 P 1 NQI 010

+0.55 UTE LTE 54 OUTLET 51OUL 122 105 0.75 92 P 1 NQI 015

-0.50 UTE LTE 64 OUTLET 51OUL 0.67 103 3 NQI 014

+31.17 UTE LTE 64 OUTLET 51OUL 123 57 0.66 84 3

NQI 011

+24.60 UTE LTE 49 OUTLET 51OUL 123 71 11.27 184 3 DNT 002

+18.14 UTE LTE 50 OUTLET 51OUL 123 86 0.25 106 3 NQI 014

+16.76 UTE LTE 49 OUTLET 51OUL 123 96 0.34 97 3

NQI 014

+1.57 UTE LTE 53 OUTLET 51OUL 123 98 0.57 91 P 1 NQI 009

-0.49 UTE LTE 53 OUTLET 51OUL 123 100 0.88 120 3 NQI 014

+1.57 UTE LTE 53 OUTLET 51OUL 123 101 0.51 84 P 1 NQI 008

-0.76 UTE LTE 54 OUTLET 51OUL 123 103 0.28 86 P 1 NQI 004

-0.41 UTE LTE 54 OUTLET 51OUL 1.94 116 3 NQI 014

+31.15 UTE LTE 54 OUTLET 51OUL 124 3 0.55 105 P 1 NQI 009

+0.57 UTE LTE 86 OUTLET 51OUL 124 6 0.46 84 3

NQI 012

+10.39 UTE LTE 85 OUTLET 51OUL 124 89 1.84 10 3

NQI 015

+25.13 UTE LTE 50 OUTLET 51OUL 124 94 1.16 111 3 TWD 9 014

+1.51 UTE LTE 59 OUTLET 51OUL 124 95 0.28 95 3

NQI 014

+16.16 UTE LTE 60 OUTLET 51OUL 124 100 0.61 112 3 NQI 007

+16.41 UTE LTE 59 OUTLET 51OUL 125 7 1.03 74 P 1 NQI 009

-0.76 UTE LTE 85 OUTLET 51OUL 125 28 1.22 126 3 NQI LTS

+21.36 TO+29.06 UTE LTE 86 OUTLET 51OUL 125 52 1.40 82 P 1 NQI 004

-0.75 UTE LTE 59 OUTLET 51OUL 125 54 1.12 85 3

NQI 015

+12.25 UTE LTE 49 OUTLET 51OUL 125 60 0.37 96 3

NQI 007

+28.90 UTE LTE 49 OUTLET 51OUL 125 90 0.59 92 3

NQI 009

+29.47 UTE LTE 59 OUTLET 51OUL 125 100 0.95 129 3 NQI 010

+18.46 UTE LTE 60 OUTLET 51OUL 126 3 0.56 92 P 1 NQI 005

-0.21 UTE LTE 90 OUTLET 51OUL 126 4 0.44 111 3 NQI 008

+33.90 UTE LTE 90 OUTLET 51OUL 126 7 0.39 112 P 1 NQI 009

+0.62 UTE LTE 90 OUTLET 51OUL 126 8 0.32 103 3 NQI 009

+8.63 UTE LTE 90 OUTLET 51OUL 126 28 0.88 67 P 1 NQI 004

-0.78 UTE LTE 89 OUTLET 51OUL 126 56 0.95 121 3 NQI 013

+12.10 UTE LTE 53 OUTLET 51OUL 126 74 0.42 95 3

NQI 010

+9.10 UTE LTE 49 OUTLET 51OUL 126 75 0.26 82 3

NQI LTS

+32.25 UTE LTE 50 OUTLET 51OUL 126 84 0.49 71 3

NQI 002

+31.02 UTE LTE 53 OUTLET 51OUL 126 97 0.23 109 P 1 NQI 008

+0.58 UTE LTE 60 OUTLET 51OUL 0.47 99 P 1 NQI 005

+1.03 UTE LTE 60 OUTLET 51OUL 127 1 0.81 63 6

ADI 014

+31.85 UTE LTE 90 OUTLET 51OUL 0.78 64 6

ADI 014

+31.81 UTE LTE 110 OUTLET SlOUL 127 6 0.28 99 P 1 NQI 015

+0.14 UTE LTE 90 OUTLET 51OUL 127 14 0.25 106 3 NQI 008

+4.21 UTE LTE 90 OUTLET 51OUL 127 15 0.27 73 3

NQI 015

+10.42 UTE LTE 90 OUTLET 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3

12/05/01 14:26:30 Component: S/G B Page 28 of 30 ATTACHMENT #2 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW 127 127 127 127 127 128 128 128 128 128 129 129 129 129 129 129 129 129 130 130 130 130 130 130 130 130 130 130 130 131 131 131 131 132 132 132 132 132 132 133 133 133 133 133 133 133 134 134 134 134 134 135 135 135 135 136 136 136 136 136 136 136 136 137 137 137 137 137 TUBE VOLTS 47 0.30 55 1.56 0.70 72 0.41 73 0.41 74 0.35 11 0.45 16 0.40 42 0.26 52 2.86 68 0.92 2

0.49 4

0.88 18 2.65 41 0.37 49 0.65 75 0.32 0.52 90 0.35 94 0.91 3

0.31 5

0.57 0.26 9

0.51 18 0.35 44 0.32 50 0.49 57 0.40 69 1.34 81 0.21 86 0.36 91 0.57 5

0.52 0.67 63 0.35 68 0.34 81 0.46 3

12.07 6

0.42 34 0.84 49 3.76 84 0.47 85 0.44 1

10.48 3

6.16 5

1.08 0.51 9

0.42 14 0.31 57 0.35 86 0.24 1

7.52 2

32.96 0.66 3

14.13 5

6.16 76 0.30 5

0.80 33 0.65 36 0.68 80 0.53 5

0.79 19 0.73 33 6.41 35 0.41 37 0.58 69 0.64 70 0.95 79 0.65 1

0.58 0.69 7

0.55 67 1.97 70 0.39 72 0.35 DEG 102 57 89 60 93 79 104 75 76 101 86 126 51 15 74 72 108 92 85 115 66 124 83 102 92 99 92 87 18 84 85 68 126 65 103 73 66 181 96 33 14 73 102 186 178 92 70 87 95 74 104 184 182 66 180 180 95 127 100 95 94 90 81 182 104 104 96 73 87 97 113 94 44 88 88 CHN 3

3 3

3 3

3 3

P 1 3

3 P 1 P 1 P1 3

3 P 1 3

3 P1 P 1 P 1 P 1 3

P 1 3

3 3

3 3

3 3

P1 P 1 P 1 P1 3

3 3

P 1 3

P 1 P 1 P 1 P 1 P1 P1 P 1 P1 3

3 P 1 P1 3

P 1 P 1 P 1 3

P 1 3

P 1 3

P 1 P 1 3

3 3

P 1 P 1 P1 3

3 3

3 3

3 IND NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI DNT NQI NQI NQI NQI NQI DNT DNT NQI NQI NQI NQI NQI NQI DNT DNT NQI DNT DNT NQI NQI NQI NQI NQI NQI NQI DNT NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI

%TW LOCATION EXT 014

+2.02 UTE 013

+25.69 UTE 013

+20.78 UTE 009

+31.57 UTE 014

+28.08 UTE LTS

+21.47 UTE LTS

+5.63 UTE 014

+0.98 UTE 009

-1.29 UTE 003

+12.66 UTE 004

-0.44 UTE 010

+0.67 UTE 004

-0.80 UTE 011

+13.20 UTE 013

+19.72 UTE 004

-0.82 UTE 008

+22.42 UTE LTS

+24.62 UTE 009

-0.51 UTE 010

-0.82 UTE 003

+0.18 UTE 010

+0.49 UTE 015

+31.26 UTE 004

-0.74 UTE 010

+21.27 UTE LTS

+23.58 UTE 007

+17.58 UTE 011

+29.36 UTE 007

+23.83 UTE 008

+25.85 UTE 009

+34.54 UTE 010

+0.68 UTE 010

+0.53 UTE 009

+0.61 UTE 002

-0.44 UTE 009

+10.68 UTE 002

+16.66 UTE LTS

+34.05 UTE 010

-0.75 UTE 009

+15.49 UTE 015

-0.37 UTE 008

+0.41 UTE 011

+0.25 UTE 015

-0.65 UTE 010

+0.44 UTE 010

-0.81 UTE 010

+0.65 UTE 009

+0.59 UTE 012

+1.56 UTE LTS

+19.88 UTE 010

+0.48 UTE 015

-0.63 UTE LTS

+4.81 UTE 004

-0.76 UTE 010

+0.35 UTE 010

+0.66 UTE 014

+25.96 UTE 010

+0.60 UTE 011

+36.62 UTE 004

-0.76 UTE 014

+16.01 UTE 014

+0.80 UTE 015

-0.80 UTE 015

+27.08 UTE 014

+31.06 UTE 002

+18.53 UTE 003

+0.84 UTE 003

+0.79 UTE 008

-0.64 UTE 011

+24.44 UTE 010

+5.64 UTE 014

+22.24 UTE 001

+4.13 UTE LTS

+36.96 UTE 010

+20.38 UTE EXT LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTIL 1 UTIL 2 CAL # LEG PROBE 103 OUTLET 51OUL 53 OUTLET 51OUL 53 OUTLET 51OUL 54 OUTLET 51OUL 53 OUTLET 51OUL 54 OUTLET 51OUL 110 OUTLET 51OUL 109 OUTLET 51OUL 104 OUTLET 51OUL 60 OUTLET 51OUL 60 OUTLET 51OUL 103 OUTLET 51OUL 103 OUTLET 51OUL 103 OUTLET 51OUL 104 OUTLET 51OUL 59 OUTLET 51OUL 59 OUTLET 51OUL 59 OUTLET 51OUL 60 OUTLET 51OUL 60 OUTLET 51OUL 110 OUTLET 51OUL 110 OUTLET 51OUL 110 OUTLET 51OUL 110 OUTLET 51OUL 110 OUTLET 51OUL 104 OUTLET 51OUL 59 OUTLET 51OUL 60 OUTLET 51OUL 60 OUTLET 51OUL 60 OUTLET 51OUL 60 OUTLET 51OUL 59 OUTLET 51OUL 109 OUTLET 51OUL 109 OUTLET 51OUL 59 OUTLET 51OUL 60 OUTLET 51OUL 59 OUTLET 51OUL 109 OUTLET 51OUL 106 OUTLET 51OUL 106 OUTLET 51OUL 60 OUTLET 51OUL 60 OUTLET 51OUL 64 OUTLET 51OUL 106 OUTLET 51OUL 106 OUTLET 51OUL 105 OUTLET 51OUL 105 OUTLET 51OUL 106 OUTLET 51OUL 105 OUTLET 51OUL 60 OUTLET 51OUL 60 OUTLET 51OUL 106 OUTLET 51OUL 105 OUTLET 51OUL 105 OUTLET 51OUL 106 OUTLET 51OUL 106 OUTLET 51OUL 59 OUTLET 51OUL 105 OUTLET 51OUL 106 OUTLET 51OUL 105 OUTLET 51OUL 60 OUTLET 51OUL 105 OUTLET 51OUL 105 OUTLET 51OUL 105 OUTLET 51OUL 105 OUTLET 51OUL 105 OUTLET 51OUL 60 OUTLET 51OUL 59 OUTLET 51OUL 60 OUTLET 51OUL 106 OUTLET 51OUL 106 OUTLET 51OUL 105 OUTLET 51OUL 60 OUTLET 51OUL 59 OUTLET 51OUL 59 OUTLET 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:26:30 Component: S/G B Page 29 of 30 ATTACHMENT #2 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW 138 138 138 138 138 139 139 140 140 140 141 141 141 141 141 141 142 142 142 142 142 143 143 143 143 143 143 143 144 144 144 144 144 144 145 145 145 145 145 145 145 145 145 145 145 146 146 146 146 146 146 146 146 146 147 147 147 147 147 147 147 147 148 148 148 148 148 TUBE 17 21 30 66 70 2

2 9 27 39 51 8

17 27 40 61 62 5

8 27 62 63 3

6 13 25 29 33 52 14 16 26 39 40 52 16 37 41 42 43 44 46 48 49 51 52 10 11 15 36 40 42 44 45 48 35 36 37 40 41 43 44 45 12 23 25 28 35 VOLTS 0.49 0.33 0.50 0.48 0.26 0.14 11.36 1.14 0.60 0.38 0.69

0. 62 0.42 0.24 0.28 0.44 0.66 3.86 2.32 0.69 0.85 1.98 0.32 0.25 0.61 0.45 0.41 0.62 0.48 0.63 0.38 0.42 0.90 1.75 0.25 0.38 0.22 0.64 0.69 0.26 0.38 0.41 0.71 0.93 0.53 0.58 0.66 0.65 0.36 0.68 0.34 0.45 0.49 0.41 0.52 0.39 0.56 0.37 0.74 0.41 3.65 0.36 0.80 0.43 7.17 0.96 13.11 0.49 13.89 0.60 0.50 0.72 0.34 0.83 31.20 DEG 82 79 90 87 102 107 181 98 69 99 57 95 90 84 63 100 83 59 39 119 129 103 85 92 100 108 76 94 95 91 77 98 80 100 90 43 62 99 110 99 52 116 56 75 42 59 57 71 81 80 76 94 110 95 105 102 50 100 93 115 96 89 34 86 190 139 176 108 182 103 113 75 105 47 185 Cl-P 3

P 3

3 3

P 3

3 3

P 3

P 3

3 3

3 6

6 P

P 3

3 3

3 3

3 3

P P

3 3

P P

3 P

P P

P P

P P

P P

P P

P P

P P

P P

3 P

3 P

P P

P P

P P

P P

P 3

P 3

P 3

P 3

3 P

P IN IND %TW 1=======

1NQI NQI 1NQI NQI NQI NQI 1 DNT NQI NQI NQI 1 NQI NQI 1 NQI NQI NQI NQI NQI ADI ADI 1 NQI 1 NQI NQI NQI NQI NQI NQI NQI NQI 1 NQI 1 NQI NQI NQI 1 NQI 1 NQI NQI 1 NQI 1 NQI 1 NQI 1 NQI 1 NQI 1 NQI 1 NQI 1 NQI 1 NQI 1 NQI 1 NQI 1 NQI 1 NQI 1 NQI 1 NQI 1 NQI 1 NQI NQI 1 NQI NQI 1 NQI 1 NQI 1 NQI 1 NQI 1 NQI 1 NQI 1 NQI 1 NQI 1 NQI 1 DNT NQI 1 DNT NQI 1 DNT NQI 1 NQI NQI NQI 1 NQI 1 DNT LOCATION UTS

+12.79 LTS

+40.43 002

-0.42 013

+12.53 014

+5.31 014

+4.62 010

+0.22 009

+7.67 013

+33.02 009

+38.40 003

-0.80 015

+10.66 010

+0.49 014

+31.48 012

+29.95 013

+6.22 007

+23.95 002

+10.50 LTS

+9.31 009

+0.55 009

-0.56 005

+25.31 012

+13.05 015

+8.34 005

+16.41 009

+29.32 011

+18.75 003

+21.56 006

-0.70 009

-0.69 LTS

+42.55 002

+36.31 UTS

+16.60 009

-0.63 010

+24.75 009

-0.78 015

-0.07 009

+0.63 009

+0.54 009

-0.18 009

-0.83 009

+0.37 009

+0.65 009

+0.61 010

-0.70 009

-0.35 009

+0.72 009

+0.67 010

+0.71 010

+0.66 010

+0.44 008

+0.42 014

+1.27 009

-0.67 014

+33.57 010

-0.58 010

-0.63 010

+0.69 015

-0.51 010

+0.60 015

-0.88 010

-0.56 015

-0.48 015

-0.15 015

-0.66 014

+1.04 015

-0.57 014

+33.05 015

-0.57 014

+30.83 008

+0.45 011

+30.49 013

+5.41 004

-0.84 015

-0.59 EXT UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE EXT LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE UTIL 1 UTIL 2 CAL # LEG 106 OUTLET 106 OUTLET 105 OUTLET 59 OUTLET 60 OUTLET 60 OUTLET 106 OUTLET 106 OUTLET 106 OUTLET 106 OUTLET 63 OUTLET 63 OUTLET 106 OUTLET 105 OUTLET 105 OUTLET 64 OUTLET 63 OUTLET 64 OUTLET 64 OUTLET 105 OUTLET 105 OUTLET 105 OUTLET 105 OUTLET 63 OUTLET 64 OUTLET 64 OUTLET 105 OUTLET 105 OUTLET 106 OUTLET 105 OUTLET 105 OUTLET 63 OUTLET 63 OUTLET 105 OUTLET 106 OUTLET 106 OUTLET 104 OUTLET 64 OUTLET 63 OUTLET 63 OUTLET 104 OUTLET 64 OUTLET 64 OUTLET 63 OUTLET 64 OUTLET 63 OUTLET 63 OUTLET 63 OUTLET 64 OUTLET 63 OUTLET 64 OUTLET 103 OUTLET 104 OUTLET 104 OUTLET 64 OUTLET 64 OUTLET 64 OUTLET 64 OUTLET 63 OUTLET 63 OUTLET 63 OUTLET 64 OUTLET 63 OUTLET 63 OUTLET 63 OUTLET 63 OUTLET 64 OUTLET 64 OUTLET 63 OUTLET 63 OUTLET 104 OUTLET 64 OUTLET 64 OUTLET 63 OUTLET 63 OUTLET PROBE 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 5lOUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 5lOUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 5lOUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 5lOUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:26:31 Component: SIG B Page 30 of 30 ATTACHMENT #2 -

LIST OF IMPERFECTIONS -

BOBBIN QUERY: QueryMl ROW TUBE VOLTS 0.36 148 36 27.92 148 37 23.35 148 38 0.88 148 40 6.07 1.22 148 41 23.97 149 1 0.60 149 16 0.47 149 17 0.91 21.11 0.64 149 24 1.24 149 27 1.13 149 29 17.25 149 30 25.06 0.40 0.46 149 31 18.89 149 32 12.07 2.23 0.89 149 33 0.59 149 34 0.75 0.44 150 17 0.40 0.46 150 23 0.62 0.37 151 3 0.29 151 6 0.50 151 8 28.83 151 9 14.36 26.79 151 16 2.11 0.97 DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 108 176 185 94 180 110 174 122 108 64 182 115 95 57 185 177 75 43 186 177 77 89 108 87 102 70 77 105 102 80 56 179 179 179 109 110 3

P1 P1 3

P1 3

P1 3

3 P1 3

3 P1 P1 P1 P1 21 P1 P1 P1 6

3 3

P1 3

3 31 3

3 21 21 3

3 3

3 3

NQI DNT DNT NQI DNT NQI DNT NQI NQI NQI DNT NQI NQI NQI DNT DNT NQI NQI DNT DNT ADI NQI NQI NQI NQI NQI NQI NQI NQI NQI NQI DNT DNT DNT NQI NQI 010 015 015 014 015 014 015 015 010 010 LTE 010 015 015 015 015 010 011 015 015 013 011 011 015 014 014 010 012 013 013 013 LTE UTS LTE 015 013

+12. 46

-0.57

-0.59

+30. 41

-0.71

+30. 56

-0.62

+14.84

+1.22

+0.73

+10. 81

+1.25

-0.84

-0.84

-0.62

-0.57

-0.66

+0.53

-0. 62

-0. 62

+5.20

+5. 64

+8.85

-0.19

+3.61

+5.73

+0.62

+3.81

+3.71

-0.76

-0.80

+10. 72

+12.75

+11. 07

-1.30

+3. 69 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 63 64 63 64 64 64 64 104 103 103 103 103 63 63 63 64 64 64 63 64 64 64 63 64 64 64 64 64 64 104 103 103 63 63 64 64 OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL Total Tubes

1879 Total Records: 2211

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:29:49 Component: S/G A Page 1 of 31 ATTACHMENT #3 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS 1

1 3.19 3.10 1

3 2.67 1

5 2.19 4.80 2

1 0.19 2

3 5.25 3.83 1.78 2

6 1.43 2

7 0.30 1.72 2

11 2.01 2

15 0.38 2

19 0.48 2

25 7.75 3

3 0.17 3

7 2.03 4.04 5.81 3

10 1.65 3

13 0.69 3

14 0.71 0.38 0.18 0.19 0.20 3

24 0.24 3

27 0.29 3

29 0.30 3

30 0.41 3

34 4.41 4

16 0.05 4

28 0.49 4

37 0.25 0.25 0.50 0.00 0.14 0.15 0.22 0.30 0.34 0.38 0.40 0.33 0.24 0.20 0.00 4

38 1.02 1.02 0.07 0.00 0.14 0.20 0.30 0.39 0.39 0.31 0.00 4.78 4

39 0.25 0.00 0.11 0.20 0.17 0.10 0.07 0.03 0.05 0.00 5.79 5

8 0.12 3.33 5

9 0.14 DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 172 178 181 172 176 101 173 163 172 18 108 178 170 49 73 152 113 23 58 172 97 104 93 58 72 79 60 32 89 132 61 27 89 17 88 88 70 0

38 40 47 53 56 58 60 58 52 41 0

31 31 96 0

72 68 57 58 56 60 0

170 86 0

92 97 103 92 121 121 101 0

179 83 183 60 DNT DNT DNT DNT DNT VOL DNT DNT DNT TEA VOL DNT DNT 3 TWD 5 3 TWD 7 DNT VOL TEA VOL DNT VOL 3 TWD 12 3 TWD 12 VOL VOL TWD 39 TWD 66 3 TWD 3 VOL VOL 3 TWD 5 TEA VOL TEA SAI TWD 75 1 SCI 5 TWD 0 5 TWD 21 5 TWD 22 5 TWD 33 5 TWD 46 5 TWD 52 5 TWD 58 5 TWD 60 5 TWD 50 5 TWD 36 5 TWD 30 5 TWD 0 SAI TWD 89 1 SCI 4 TWD 0 4 TWD 27 4 TWD 39 4 TWD 57 4 TWD 75 4 TWD 74 4 TWD 59 4 TWD 0 DNT 1 SCI 4 TWD 0 4 TWD 7 4 TWD 12 4 TWD 10 4 TWD 6 4 TWD 4 4 TWD 2 4 TWD 3 4 TWD 0 DNT VOL DNT VOL 015 015 015 015 UTS 015 LTS 015 015 UTE 014 015 UTS 010 010 UTS 013 UTE 015 LTE 015 013 014 015 015 015 015 010 003 011 011 UTE LTS UTE 015 015 015 015 015 015 015 015 015 015 015 015 015 015 015 UTE UTE 015 015 015 015 015 015 015 015 015 UTS 015 015 015 015 015 015 015 015 015 015 UTS 015 UTS 015

-0.40

+0.59

-0.24

+0.73

+0.07

-5. 94

-13.51

-0.08

+0.51

-0.18

-0.30

+0.68

-0.15

+0.67

+0.62

+0.01

+4. 61

-0.19

+26.89 TO+36.49

+11.08

-1.27

-0.49

-0.60

+0.70

-0.29

+0.70

-0.29

+0.47

+3.48

-0.49

-0.67

-0.25

+9.43

-0. 19

-6.75

-6.75

+0.82

+0.82 TO+280.0

+0.82 TO+290.0

+0.82 TO+300.0

+0.82 TO+310.0

+0.82 TO+320.0

+0.82 TO+330.0

+0.82 TO+340.0

+0.82 TO+350.0

+0.82 TO+0.0

+0.82 TO+10.0

+0.82 TO+20.0

+0.82 TO+30.0

-1.11

-1.11

+0.52

+0.52 TO+53.7

+0.52 TO+43.0

+0.52 TO+32.2

+0.52 TO+21.5

+0.52 TO+10.7

+0.52 TO+0.0

+0.52 TO+349.3

+0.52 TO+338.5

-0.02

+0.55

+0.55 TO+225.7

+0.55 TO+214.9

+0.55 TO+204.2

+0.55. TO+193.4

+0.55 TO+182.7

+0.55 TO+171.9

+0.55 TO+161.2

+0.55 TO+150.4

+0.55 TO+145.1

+0.02

+14.08

+0.04

+14.10 015 015 015 015 UTS 015 LTS 015 015 UTE 014 015 015 010 010 UTS 013 UTE 015 LTE 014 013 014 015 015 015 015 010 003 011 011 UTE LTS UTE 015 015 015 015 015 015 015 015 015 015 015 015 015 015 015 UTE UTE 015 015 015 015 015 015 015 015 015 UTS 015 015 015 015 015 015 015 015 015 015 UTS 015 UTS 015 015 015 015 015 UTS 015 LTS 015 015 UTE 014 015 UTS 010 010 UTS 013 UTE 015 LTS 015 013 014 015 015 015 015 010 003 011 011 UTE LTS UTE 015 015 015 015 015 015 015 015 015 015 015 015 015 015 015 UTE UTE 015 015 015 015 015 015 015 015 015 UTS 015 015 015 015 015 015 015 015 015 015 UTS 015 UTS 015 WAR WAR WAR WAR WAR WAR 4034 4034 4034 4034 4034 4034 4034 4034 4034 2043 4034 4034 4034 4032 4032 4032 4034 2043 4034 4034 4034 4034 4034 4034 4034 4034 4034 4032 4035 4035 4035 2044 4034 2043 4035 4035 4035 4035 4035 4035 4035 4035 4035 4035 4035 4035 4035 4035 4035 2044 2044 4066 4066 4066 4066 4066 4066 4066 4066 4066 4035 4066 4066 4066 4066 4066 4066 4066 4066 4066 4066 4035 4034 4034 4034 OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET INLET INLET INLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 4 60HR 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 4 60HR 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI TR

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:29:49 Component: S/G A Page 2 of 31 ATTACHMENT #3 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS 0.13 5

32 6.17 5

42 0.07 5

44 0.28 6

10 0.16 6

14 0.09 0.09 0.09 0.09 6

22 0.51 0.50 6

33 0.58 6

35 0.52 6

39 0.15 0.15 6

41 0.19 0.19 6

42 1.87 6

49 0.16 0.09 0.19 0.09 7

10 0.52 7

13 0.06 7

16 0.16 0.16 7

18 15.56 12.75 7

19 0.65 7

20 0.73 7

23 0.30 7

43 1.18 7

45 2.03 0.60 7

48 0.11 7

52 0.41 8

7 0.10 8

9 0.40 8

11 0.50 0.34 8

12 0.28 8

14 0.33 8

20 0.24 8

27 0.04 8

42 0.66 8

44 1.17 8

50 0.77 9

17 0.09 9

19 1.25 9

21 0.07 9

29 0.22 9

42 0.17 9

54 0.25 10 2

0.53 10 12 0.11 0.36 10 18 0.33 10 19 0.40 0.48 10 20 0.17 10 44 0.39 10 49 0.79 10 50 0.77 10 58 0.22 11 1

0.64 11 16 0.40 11 22 2.13 0.36 11 41 1.50 11 59 0.35 12 5

1.47 0.07 12 7

1.49 12 12 0.09 12 14 0.29 DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 75 169 46 66 118 95 95 88 88 118 70 92 37 88 88 73 73 27 50 72 56 74 101 45 67 67 179 180 0

0 125 20 27 88 76 76 31 100 77 93 104 98 70 78 137 19 45 59 28 49 80 60 99 70 77 71 108 143 76 90 149 36 23 49 76 111 26 97 17 111 23 73 18 85 108 TWD 45 DNT VOL VOL VOL SAI TWD 10 SAI TWD 23 3 TWD 9 3 TWD 9 3 TWD 7 3 TWD 7 SAI TWD 75 SAI TWD 83 TEA VOL VOL TWD 64 TWD 34 3 TWD 9 VOL SAI TWD 19 DNT DNT 3 TWD 9 3 TWD 11 VOL TEA TEA 3 TWD 7 VOL 3 TWD 5 VOL VOL 3 TWD 9 3 TWD 6 VOL VOL VOL VOL 3 TWD 8 TEA 3 TWD 9 VOL TEA VOL VOL VOL VOL 3 TWD 9 VOL VOL VOL VOL VOL VOL VOL TEA TEA VOL 3 TWD 9 VOL TEA VOL TEA VOL TEA VOL TEA VOL VOL 015 LTS 004 011 010 015 015 015 015 009 009 009 009 015 015 015 015 UTE UTS UTS UTS UTS 008 014 014 014 UTS UTS 009 009 009 UTE UTE 009 005 010 008 008 008 015 010 010 009 014 009 UTE 007 012 UTE 003 014 015 010 008 015 UTS 008 008 009 010 009 UTE UTE 010 008 008 UTE 007 UTE 010 UTE 002 UTE 006 015

+14.10

-5.22

-4.31

-0.81

+3.20

-7. 09

-7.09

-6.74

-6.74

-0.62

+0.37

-0.54

+0.37

-6.08

-6.08

-5.50

-5.50

-0.23

+0.22

+0.34

+0.22

+0.34

-0.65

-13.52

+30.35

+30. 35

+1.37

+1.15

-0.56

-0.58

-0.55

-0.20

-0.21

-0.63

+1. 10

+0.55

-18.50

-0.65

-0.59

+0.77

-13.32 TO-18.11

-20.50 TO-9.10

-0.69

+1.26

-0.61

-0.18

+0.70

+9.82

-0.17

-16.63

+1.23

-11.80

-20.25 TO-9.28

-0.68

+1.06

-10.39

-0.67

-0.68

-0.41

+1.13

+0.37

-0.19

-0.21

-13.90

-0.76

-0.65

-0.16

-0.74

-0.23

-26.10 TO-3.09

-0.20

+15.39

-0.17

-15.38

+0.44 015 LTS 004 011 010 015 015 015 015 009 009 009 009 015 015 015 015 UTE UTS UTS UTS UTS 008 014 014 014 UTS UTS 009 009 009 UTE UTE 009 005 010 008 008 008 015 010 010 009 014 009 UTE 007 012 UTE 003 014 015 010 008 015 UTS 008 008 009 010 009 UTE UTE 010 008 008 UTE 007 UTE 010 UTE 002 UTE 006 015 015 LTS 004 011 010 015 015 015 015 009 009 009 009 015 015 015 015 UTE UTS UTS UTS UTS 008 014 015 015 UTE UTE 009 009 009 UTE UTE 009 005 010 008 008 008 015 010 010 009 015 009 UTE 007 012 UTE 003 015 015 010 008 015 UTS 008 008 009 010 009 UTE UTE 010 008 008 UTE 007 UTE 010 UTE 002 UTE 006 015 WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR 4034 4035 4035 4035 4034 4034 4034 4034 4034 4031 4031 4035 4035 4035 4035 4035 4035 2044 4035 4035 4035 4035 4034 4034 4031 4031 4031 4031 4031 4031 4031 2040 2039 4035 4035 4035 4034 4034 4034 4034 4034 4034 4031 4031 4035 2039 4035 4031 2043 4031 4031 4035 4035 4031 4031 4031 4031 4031 4031 4031 4038 2040 2039 4038 4031 4031 2043 4031 2040 4038 2043 4031 2043 4031 4031 OUTLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET OUTLET INLET OUTLET OUTLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET OUTLET OUTLET INLET OUTLET INLET INLET INLET OUTLET INLET OUTLET OUTLET 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 4 60HR 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 4 60HR 4 60HR 460SI 460SI 460SI 460HR 460SI 4 60HR 460SI 460HR 460SI 460HR 460SI 460SI

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:29:49 Component: S/G A Page 3 of 31 ATTACHMENT #3 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW 12 12 12 12 12 12 13 13 13 13 13 13 13 13 13 13 14 14 14 14 14 14 14 14 14 15 15 15 15 15 15 16 16 16 16 16 16 16 16 16 16 17 17 17 17 17 17 17 17 TUBE 42 43 57 58 70 71 27 31 36 47 51 55 63 72 73 74 7

9 11 19 53 58 66 74 75 5

14 27 70 75 77 8

21 28 46 57 59 61 74 78 81 2

5 7

8 9

10 16 57 VOLTS 0.16 1.54 0.64

0. 90 0.33 3.37 1.84 0.73 0.18 0.15 2.45 1.91 0.08 2.40 0.22 0.27 5.34 8.59 3.49 1.72 0.57
0. 19
0. 19 2.51 0.92 0.21 0.05 0.40 0.10 0.10 0.64 0.24 0.44 4.11 0.25 0.08 0.08 2.11 0.40 0.08 3.24 0.41 0.12
0. 19 0.13 1.45 0.78 4.44 0.10 1.54 9.35 1.06 0.26 0.18 1.89 0.67 0.55
1. 19 2.51 1.76
0. 67
0. 92 0.45 0.39 0.16
0. 19 0.28 0.45 0.39 0.30 0.27 0.32 0.32 0.32 0.31 DEG 60 24 121 81 76 193 26 61 89 82 17 25 70 177 108 131 169 176 180 30 78 62 62 20 61 88 54 80 71 71 109 92 94 183 64 95 95 35 98 67 31 93 67 67 97 24 21 163 79 32 182 27 110 64 27 59 94 23 22 23 99 18 23 29 51 48 38 29 36 37 36 30 27 21 46 CHN IND %TI 2

VOL 2

TEA 2

VOL P 3 TWD 11 P 3 TWD 7 1

DNT 2

TEA P 3 TWD 11 2

VOL 2

VOL 2

TEA 2

TEA 2

VOL 1

DNT 2

VOL 2

VOL 1

DNT 1

DNT 1

DNT 2

TEA P 3 TWD 8 2

SAI 2

TWD 70 2

TEA P 3 TWD 13 P 1 VOL 2

VOL P 3 TWD 5 2

SAI 2

TWD 49 1

VOL 2

VOL 1

VOL 1

DNT P 3 TWD 4 2

SAI 2

TWD 0 2

TEA P 3 TWD 6 2

VOL 2

TEA 2

VOL P 1 VOL P 1 VOL 2

VOL 2

TEA 2

TEA 1

DNT 2

VOL 2

TEA 1

DNT 2

TEA 2

VOL 2

VOL 2

TEA P 3 TWD 10 P 3 TWD 8 2

TEA 2

TEA 2

TEA P 3 TWD 10 2

TEA P 1 SCI P 1 TWD 99 P 3 TWD 0 P 3 TWD 27 P 3 TWD 43 P 3 TWD 85 P 3 TWD 69 P 3 TWD 48 P 3 TWD 42 P 3 TWD 52 P 3 TWD 53 P 3 TWD 52 P 3 TWD 49

' LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG UTS UTE 007 009 008 UTS UTE 011 004 014 UTE UTE 010 UTS 012 010 UTS UTS 015 UTE 015 014 014 UTE 007 004 010 015 014 014 010 010 010 UTS 010 015 015 UTE 009 013 UTE 010 014 013 LTS UTE UTE 009 001 UTE 006 UTE 010 014 UTE 010 008 UTE UTE UTE 009 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE

+6.39 UTS

-0.20 UTE

-0.63 007

+0.61 009

-0.59 008

+0.01 UTS

-0.18 UTE

-0.76 011

+12.49 004

+1.04 014

-0.17 UTE

-0.24 UTE

+6.46 010

+0.04 UTS

+0.70 012

-0.15 010

+0.05 UTS

+0.04 UTS

+0.60 015

-0.19 UTE

+0.30 015

+7.09 014

+7.09 014

-0.16 UTE

-0.71 007

-16.81 004

+16.62 010

+0.43 015

+15.40 014

+15.40 014

-14.98 010

-16.00 010

-16.90 010

+0.05 UTS

+0.34 010

-2.51 015

-2.51 015

-0.18 UTE

+0.54 009

-1.29 013

-0.16 UTE

-3.33 TO-17.44 010

+0.94 014

-10.71 013

+0.53 LTS

-0.18 UTE

-0.16 UTE

-10.28 009

-19.81 001

-0.21 UTE

-1.48 006

-0.21 UTE

-9.56 TO-20.32 010

+0.75 014

-0.14 UTE

+0.52 010

+0.41 008

-0.20 UTE

-0.15 UTE

-0.18 UTE

-0.79 009

-0.17 UTE

-3.47 UTE

-3.47 TO+120.0 UTE

-3.47 TO+95.2 UTE

-3.47 TO+103.4 UTE

-3.47 TO+111.7 UTE

-3.47 TO+120.0 UTE

-3.47 TO+128.3 UTE

-3.47 TO+136.6 UTE

-3.47 TO+144.8 UTE

-3.47 TO+153.1 UTE

-3.47 TO+161.4 UTE

-3.47 TO+169.7 UTE

-3.47 TO+177.9 UTE UTS UTE 007 009 008 UTS UTE 011 004 014 UTE UTE 010 UTS 012 010 UTS UTS 015 UTE 015 014 014 UTE 007 004 010 015 014 014 010 010 010 UTS 010 015 015 UTE 009 013 UTE 010 014 013 LTS UTE UTE 009 001 UTE 006 UTE 010 014 UTE 010 008 UTE UTE UTE 009 UTE UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR TR 4038 2039 4038 4038 4038 4038 2043 4031 4031 4038 2040 2040 4038 4038 4038 4038 4038 4038 4038 2049 4031 4031 4031 2050 4031 4046 4046 4046 4046 4046 4046 4046 4046 4038 4038 4038 4038 2049 4031 4031 2049 4032 4046 4038 4038 2049 2050 4027 4046 2039 4046 2039 4032 4032 2064 4031 4031 2049 2050 2049 4031 2050 2039 2039 2039 2039 2039 2039 2039 2039 2039 2039 2039 2039 2039 INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET INLET INLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 460SI 460HR 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460HR 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 4 60HR 460SI 460SI 460SI 4 60HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 4 60HR 460SI 460SI 4 60HR 460SI 460SI 460SI 460SI 460HR 460HR 460SI 460SI 460HR 460SI 460HR 460SI 460SI 460HR 460SI 460SI 460HR 460HR 460HR 460SI 460HR 460HR 460HR 460HR 4 60HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:29:49 Component: S/G A Page 4 of 31 Component: S/G A Page 4 of 31 ATTACHMENT #3 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS 0.36 0.45 0.34 0.15 0.14 0.26 0.25 0.22 0.12 0.15 17 58 1.99 17 64 2.51 17 73 0.31 0.30 17 74 0.20 0.19 0.40 0.26 0.26 17 75 0.46 0.44 17 76 0.39 0.54 17 77 0.29 0.28 17 78 0.46 0.45 17 79 0.34 18 10 0.93 18 49 0.35 0.35 0.45 0.45 18 60 2.02 18 62 0.35 18 73 2.31 2.31 18 75 0.13 0.12 18 76 0.18 0.35 18 77 0.56 0.47 18.45 18 79 0.31 18 84 4.93 18 85 0.10 19 16 1.56 19 18 1.79 19 24 1.76 19 32 1.83 19 33 1.67 19 46 0.58 19 60 1.68 19 74 1.73 19 77 0.13 0.13 19 80 0.33 0.52 20 19 2.74 20 38 0.22 20 55 8.09 20 75 0.76 21 5

0.84 21 6

0.34 21 9

1.38 21 11 2.02 21 33 0.22 21 35 1.44 21 52 0.98 0.36 21 62 0.08 21 78 0.73 22 14 1.24 22 26 0.11 DEG 26 22 28 42 41 35 33 31 47 47 23 16 106 106 134 126 91 119 119 92 92 92 87 93 93 88 88 98 88 59 59 53 53 24 52 24 26 58 58 85 55 85 91 183 91 159 72 20 20 22 23 28 23 26 22 66 66 88 97 22 60 168 16 142 132 30 19 87 21 41 90 66 27 35 60 CHN IND %T1 P 3 TWD 0 P 1 SCI P 1 TWD 98 P 3 TWD 0 P 3 TWD 77 P 3 TWD 97 P 3 TWD 97 P 3 TWD 94 P 3 TWD 60 P 3 TWD 0 2

TEA 2

TEA 2

VOL 2

TWD 0 2

VOL 2

TWD 0 2

VOL 2

VOL 2

TWD 0 2

VOL 2

TWD 7 2

VOL 2

TWD 15 2

VOL 2

TWD 5 2

VOL 2

TWD 13 2

VOL P 3 TWD 13 2

SAI 2

TWD 67 2

SAI 2

TWD 76 2

TEA P 3 TWD 4 2

SAI 2

TWD 78 2

VOL 2

TWD 59 2

VOL 2

TWD 63 P 3 TWD 6 2

VOL 1

DNT 2

VOL 1

DNT 2

VOL 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 2

TEA 2

VOL 2

TWD 47 2

VOL 2

TWD 0 2

TEA 2

VOL 1

DNT 2

TEA P 3 TWD 14 2

VOL 2

TEA 2

TEA 2

VOL 2

TEA 2

TEA 2

VOL 2

VOL 2

TEA 2

TEA 2

VOL W LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 009 009 011 011 009 009 009 010 010 010 010 010 010 010 010 014 009 UTS UTS UTS UTS UTE 015 UTE UTE 014 014 014 014 014 010 LTS 010 LTS 004 UTE UTE UTE UTE UTE UTE UTE UTE 014 014 014 014 UTE 014 002 UTE 009 010 UTE UTE 015 UTE UTE 014 015 UTE UTE 014

-3.47 TO+186.2

-3.51

-3.51 TO+322.8

-3.51 TO+297.9

-3.51 TO+306.2

-3.51 TO+314.5

-3.51 TO+322.8

-3.51 TO+331.0

-3.51 TO+339.3

-3.51 TO+347.6

-0.32

-0.32

+18.13 TO+27.91

+18.13 TO+27.91

-0.74

-0.74

+18.86 TO+29.30

+18.86 TO+29.30

+18.86 TO+29.30

-9.69 TO-21.98

-9.69 TO-21.98

-9.04 TO-21.19

-9.04 TO-21.19

-8.52 TO-19.28

-8.52 TO-19.28

-10.72 TO-18.04

-10.72 TO-18.04

+0.93

-0.74

-5.62

-5.62

-6.03

-6.03

-0.23

+0.27

-0.35

-0.35

+1.04

+1.04

+0.84

+0.84

+0.69

-11.87 TO-27.10

+14.24

-12.42 TO-23.20

-14.22

-6.90

-0.34

-0.18

-0.12

-0.31

-0.16

-0.20

-0.21

-0.18

+1.16

+1.16

+0.68

+0.68

-0.20

+0.55

-8.97

-0.21

-0.46

+0.48

-0.20

-0.18

+0.79

-0.11

-0.23

+0.71

-7.47

-0. 19

-0.09

+10.07 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 009 009 011 011 009 009 009 010 010 010 010 010 010 010 010 014 009 UTS UTS UTS UTS UTE 015 UTE UTE 014 014 014 014 014 010 LTS 010 LTS 004 UTE UTE UTE UTE UTE UTE UTE UTE 014 014 014 014 UTE 014 002 UTE 009 010 UTE UTE 015 UTE UTE 014 015 UTE UTE 014 UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS UTE UTE 009 009 011 011 010 009 009 010 010 010 010 010 010 010 010 014 009 UTS UTS UTS UTS UTE 015 UTE UTE 014 014 014 014 014 010 LTS 010 LTS 004 UTE UTE UTE UTE UTE UTE UTE UTE 014 014 014 014 UTE 014 002 UTE 009 010 UTE UTE 015 UTE UTE 014 015 UTE UTE 014 IDOK WAR WAR CL 2039 2039 2039 2039 2039 2039 2039 2039 2039 2039 2040 2040 4032 4032 4059 4059 4059 4032 4032 4032 4032 4032 4032 4032 4032 4032 4032 4032 4031 4046 4046 4046 4046 2039 4046 2040 2040 4032 4032 4032 4032 4046 4046 4046 4032 4059 4059 2050 2050 2050 2050 2049 2039 2039 2039 4032 4032 4032 4032 2050 4027 4059 2039 4029 4029 2049 2049 4027 2049 2039 4032 4032 2039 2049 4029 INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET INLET OUTLET OUTLET INLET INLET OUTLET INLET INLET INLET INLET INLET INLET OUTLET 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460HR 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460HR 4 60HR 460HR 460HR 460HR 4 60HR 4 60HR 460SI 460SI 460SI 460SI 4 60HR 460SI 460SI 4 60HR 460SI 460SI 4 60HR 460HR 460SI 4 60HR 4 60HR 460SI 460SI 4 60HR 4 60HR 460SI WAR WAR

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:29:49 Component: S/G A Page 5 of 31 ATTACHMENT #3 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW 22 22 22 22 23 23 23 23 23 23 23 23 23 23 24 24 24 24 24 25 25 25 25 25 25 25 26 26 26 27 27 27 27 27 28 TUBE VOLTS 51 5.29 64 3.22 91 0.93 93 12.30 8.79 2

0.41 3

0.27 5

0.46 14 1.39 36 0.55 44 14.41 65 0.54 82 0.25 93 5.68 5.80 94 7.33 0.42 4

0.25 5

0.33 0.33 11 2.00 22 2.56 44 0.17 15 0.16 66 1.25 67 1.42 81 0.46 83 0.17 0.12 94 1.20 1.33 95 0.78 23 1.12 54 0.11 92 1.39 24 0.81 68 0.19 72 0.25 92 0.14 98 0.20 0.28 37 0.07 0.07 0.06 0.06 0.09 0.09 0.08 0.08 0.12 0.12 0.11 0.11 0.23 0.23 0.16 0.16 0.18 0.18 0.19 0.19 0.14 0.14 0.13 0.13 0.14 0.14 0.22 0.22 0.17 0.17 0.34 0.31 0.41 0.41 DEG CHN IND 168 1 DNT 25 2

TEA 66 P 3 TWD 179 1 DNT 181 1 DNT 135 2 VOL 56 2

VOL 83 P 3 TWD 20 2

TEA 19 2

TEA 171 1 DNT 21 2

TEA 159 2 VOL 179 1 DNT 170 1 DNT 173 1 DNT 96 P 3 TWD 66 2

VOL 146 2 VOL 121 2 VOL 22 2

TEA 26 2

TEA 61 2

VOL 60 2

VOL 26 2

TEA 28 2

TEA 20 2

TEA 17 2

VOL 67 2

VOL 68 P 3 TWD 70 P 3 TWD 84 P 3 TWD 13 2

TEA 57 2

VOL 63 P 3 TWD 16 2

TEA 73 2

VOL 17 2

VOL 71 2

VOL 63 2

VOL 98 2

VOL 111 2 SAI 111 2 TWD 97 2

SAI 97 2

TWD 75 2

SAI 75 2

TWD 81 2

SAI 81 2

TWD 65 2

SAI 65 2

TWD 110 2 SAI 110 2 TWD 56 2

SAI 56 2

TWD 72 2

SAI 72 2

TWD 70 2

SAI 70 2

TWD 107 2 SAI 107 2 TWD 94 2

SAI 94 2

TWD 77 2

SAI 77 2

TWD 95 2

SAI 95 2

TWD 59 2

SAI 59 2

TWD 46 2

SAI 46 2

TWD 50 2

SAI 50 2

TWD 40 2

SAI 40 2

TWD

%TW LOCATION 002

+6.05 UTE

-0.18 12 010

+0.65 UTS

+0.02 015

+0.66 010

+0.38 009

+14.44 10 009

-0.59 UTE

-0.15 UTE

-0.09 LTS

+17.72 UTE

-0.19 009

-0.18 UTS

+0.09 UTS

-0.07 UTS

+0.03 9

011

-0.71 009

+0.66 009

-0.32 010

+0.53 UTE

-0.13 UTE

-0.27 014

+0.24 008

+10.97 UTE

-0.18 UTE

-0.21 UTE

-0.21 UTS

-12.45 UTS

-12.64 13 009

-0.57 14 009

+0.70 9

008

+0.62 UTE

-0.17 010

+16.79 15 008

-0.46 UTE

-0.22 014

+0.40 015

+0.36 010

+10.99 015

-1.83 011

-0.74 011

-2.60 30 011

-2.60 011

-3.33 34 011

-3.33 011

-3.68 44 011

-3.68 011

-4.01 41 011

-4.01 011

-4.39 50 011

-4.39 011

-4.63 30 011

-4.63 011

-5.19 58 011

-5.19 011

-5.42 46 011

-5.42 011

-5.57 47 011

-5.57 011

-5.68 31 011

-5.68 011

-5.94 35 011

-5.94 011

-6.16 43 011

-6.16 011

-6.49 35 011

-6.49 013

-0.90 TO-1.49 55 013

-0.90 TO-1.49 013

-1.65 69 013

-1.65 013

-2.41 64 013

-2.41 013

-3.92 78 013

-3.92 EXT 002 UTE 010 UTS 015 010 009 009 UTE UTE LTS UTE 009 UTS UTS UTS 011 009 009 010 UTE UTE 014 008 UTE UTE UTE UTS UTS 009 009 008 UTE 010 008 UTE 014 015 010 015 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 013 013 013 013 013 013 013 013 EXT 002 UTE 010 UTS 015 010 009 009 UTE UTE LTS UTE 009 UTS UTS UTS 011 009 009 010 UTE UTE 014 008 UTE UTE UTE UTS UTS 009 009 008 UTE 010 008 UTE 014 015 010 015 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 013 013 013 013 013 013 013 013 UTIL 1 UTIL 2 WAR WAR WAR WAR WAR WAR WAR CAL #

4046 2039 4032 4038 4038 4054 4054 4054 2050 2050 4054 2039 4032 4059 4038 4038 4038 4054 4054 4027 2053 2054 4027 4027 2035 2035 2035 4032 4032 4046 4046 4046 2053 4032 4046 2053 4032 4032 4046 4046 4046 4027 4027 4027 4027 4027 4027 4027 4027 4027 4027 4027 4027 4027 4027 4027 4027 4027 4027 4027 4027 4027 4027 4027 4027 4027 4027 4027 4027 4027 4027 4027 4027 4027 4027 LEG INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET INLET INLET INLET INLET OUTLET INLET INLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET PROBE 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460SI 4 60HR 4 60HR 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 4 60HR 460SI 460SI 460HR 460HR 460HR 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:29:49 Component: S/G A Page 6 of 31 ATTACHMENT #3 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 0.18 0.18 28 56 0.12 28 64 0.08 28 70 2.17 28 84 1.06 28 90 0.42 29 2

0.61 29 56 0.16 29 57 0.29 29 69 1.74 30 1

0.30 0.20 0.23 0.30 30 50 9.97 30 80 0.15 30 88 1.40 31 2

0.31 0.31 31 8

0.51 31 50 2.55 31 53 1.23 31 56 0.13 0.13 31 57 0.14 0.11 0.08 31 59 0.08 31 61 0.19 31 71 0.18 31 73 6.08 31 74 0.14 0.12 0.23 31 105 0.16 32 1

0.32 32 3

0.76 32 14 0.11 32 69 0.09 0.06 0.13 33 1

0.31 33 3

0.35 33 6

0.33 33 7

0.17 0.17 0.08 0.08 0.08 0.08 33 12 0.63 33 17 3.08 33 21 0.20 33 53 0.10 34 6

0.13 34 13 0.25 34 41 0.09 34 45 0.15 34 64 0.19 34 86 0.23 34 87 0.11 34 88 0.10 34 89 0.64

0. 64 35 1

4.93 35 2

0.32 35 41 0.23 35 42 0.21 35 52 4.12 35 90 0.14 35 108 11.11 0.44 10.46 36 1

0.10 107 2 SAI 107 2 TWD 31 37 P 1 VOL 65 2

VOL 24 2

TEA 20 2

TEA 84 P 3 TWD 5 122 2 VOL 82 2

VOL 74 P 1 VOL 31 2

TEA 121 2 VOL 80 2

SAI 78 2

TWD 42 121 2 TWD 0 177 1 DNT 76 2

VOL 15 2

TEA 130 2 VOL 130 2 TWD 0 89 P 3 TWD 7 27 2

TEA 14 2

TEA 72 2

SAI 72 2

TWD 54 114 2 VOL 63 2

VOL 57 2

VOL 57 P 1 VOL 64 2

VOL 97 2

VOL 182 1 DNT 71 2

VOL 62 P I VOL 61 2

VOL 72 2

VOL 40 2

VOL 137 P 3 TWD 17 60 2

VOL 49 2

VOL 52 2

VOL 54 2

VOL 109 2 VOL 73 2

VOL 140 2 VOL 67 2

SAI 67 2

TWD 66 65 2

SAI 65 2

TWD 69 56 2

SAI 66 2

TWD 68 21 2

TEA 169 1 DNT 76 2

VOL 50 2

VOL 62 2

VOL 157 2 VOL 75 2

VOL 106 2 VOL 70 2

VOL 101 2 VOL 75 2

VOL 67 2

VOL 67 2

VOL 66 2

TWD 42 0

1 DNT 75 2

VOL 62 P 3 TWD 4 102 2 VOL 168 1 DNT 122 2 VOL 167 1 DNT 107 2 VOL 161 1 DNT 79 2

VOL 013 013 013 012 UTE UTE 001 010 014 014 UTE 015 015 015 015 001 014 UTE 012 012 010 UTE UTE UTS UTS 014 012 012 011 011 015 006 010 008 006 UTS 015 010 008 008 008 008 012 010 010 013 013 013 013 013 013 UTE 013 014 010 009 008 007 014 004 003 015 011 001 001 015 UTS 015 014 LTS 001 UTS UTS 015 010

-4.51

-4.5 1

-16.24

-17.31

-0.20

-0. 19

-0.34

-0.21

+1.02

+1.00

-0.19

+1.22

+9.54

+9.54

+1.22

+10. 83

+1.01

-0.13

+0.71

+0.71

+0.58

-0.24

-0.22

-5.35

-5.35

-0.53

-13.97

-16.13

+7.10

+2. 95

+0.55

-1.65

-15.95

+7. 64

+17.02

-8.78

+18.65

+0.66

-17.37

-8.31

-10.06

-14.72

+0.76

-0.33

+0.50

+14.31

+14.31

+7.71

+7.71

+7.54

+7.54

-0.15

+6.60

+0.98

-13.21

-1.57

-0.69

-19.25

+0.48

+9.83

-0.77

+0. 19

+5.19

+0.80

+0.80

+0.88

-11.04

+0.72

+0.45

+18.32

+0. 91

+0. 12

-14.24

+0. 70

+4.87 013 013 013 013 013 013 012 012 UTE UTE UTE UTE 001 001 010 010 014 014 014 014 UTE UTE 015 015 015 015 015 015 015 015 001 001 014 014 UTE UTE 012 012 012 012 010 010 UTE UTE UTE UTE UTS UTS UTS UTS 014 014 012 012 012 012 011 011 011 011 015 015 006 006 010 010 008 008 006 006 UTS UTS 015 015 010 010 008 008 008 008 008 008 008 008 012 012 010 010 010 010 013 013 013 013 013 013 013 013 013 013 013 013 UTE UTE 013 013 014 014 010 010 009 009 008 008 007 007 014 014 004 004 003 003 015 015 011 011 001 001 001 001 015 015 UTS UTS 015 015 014 014 LTS LTS 001 001 UTS UTS UTS UTS 015 015 010 010 WAR WAR WAR WAR 4027 OUTLET 4027 OUTLET 4046 INLET 4046 INLET 2035 INLET 2035 INLET 4046 INLET 4027 OUTLET 4046 INLET 4046 INLET 2031 INLET 4027 OUTLET 4027 OUTLET 4027 OUTLET 4027 OUTLET 4034 OUTLET 4046 INLET 2031 INLET 4027 OUTLET 4027 OUTLET 4027 OUTLET 2053 INLET 2053 INLET 4046 INLET 4046 INLET 4046 INLET 4046 INLET 4046 INLET 4046 INLET 4046 INLET 4046 INLET 4046 INLET 4046 INLET 4046 INLET 4046 INLET 4046 INLET 4027 OUTLET 4027 OUTLET 4025 OUTLET 4048 INLET 4048 INLET 4048 INLET 4027 OUTLET 4027 OUTLET 4025 OUTLET 4054 INLET 4054 INLET 4054 INLET 4054 INLET 4054 INLET 4054 INLET 2057 INLET 4029 OUTLET 4029 OUTLET 4034 OUTLET 4027 OUTLET 4025 OUTLET 4022 OUTLET 4022 OUTLET 4048 INLET 4048 INLET 4048 INLET 4048 INLET 4048 INLET 4048 INLET 4022 OUTLET 4027 OUTLET 4022 OUTLET 4022 OUTLET 4034 OUTLET 4046 INLET 4059 OUTLET 4059 OUTLET 4038 INLET 4022 OUTLET 460SI 460SI 460SI 460SI 460HR 460HR 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460HR 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:29:49 Component: SIG A Page 7 of 31 ATTACHMENT #3 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 36 36 36 36 36 36 37 37 37 37 38 38 38 38 39 39 39 40 40 40 40 40 40 41 41 41 42 42 43 43 43 43 43 43 43 44 44 44 45 45 45 45 45 45 45 45 46 46 46 46 46 47 47 47 47 47 22 44 96 108 111 113 4

22 47 54 3

4 74 115 74 114 115 1

2 12 76 114 115 77 103 113 96 116 1

7 63 66 73 83 116 4

34 38 6

29 44 59 64 72 73 117 7

59 68 77 105 7

57 63 83 104 0.22 0.25 0.19 1.45 0.25 0.16 0.14 0.14 0.21 0.14 0.16 10.40 0.16 0.26

0. 11
0. 11 0.42 1.16 0.38 0.14 0.17 1.94 0.96 0.24 0.22 0.20 0.41 4.84 0.19 1.10 0.09 0.52 0.19 0.55 0.30 0.23 0.40 2.89 0.14 0.09 0.13 0.89 0.23 0.23 1.48 1.02
0. 11
0. 11 1.89 1.28 0.21 0.12 0.15 0.15 0.15 0.15 0.17 0.07 0.04 0.23 0.21 1.82 3.41 0.21
0. 10
0. 10 0.24 0.09 1.87 2.61 0.14 0.18 0.18 0.94 0.09 104 2 VOL 48 P 3 TWD 3 57 2

VOL 72 P 3 TWD 16 100 P 1 VOL 69 2

VOL 88 2

VOL 88 2

TWD 21 78 2

VOL 83 2

VOL 39 2

VOL 171 1 DNT 112 2 VOL 77 2

VOL 52 2

SAI 52 2

TWD 92 90 P 3 TWD 7 29 2

TEA 80 2

VOL 84 2

VOL 64 2

VOL 20 2

TEA 150 P 3 TWD 12 97 2

VOL 34 2

VOL 85 2

VOL 60 P 3 TWD 5 175 1 DNT 75 2

VOL 74 P 3 TWD 13 53 2

VOL 20 2

VOL 73 2

TWD 45 69 2

VOL 107 2 TWD 0 122 2 VOL 117 2 VOL 169 1 DNT 76 2

VOL 52 2

VOL 52 2

VOL 83 P 3 TWD 14 015 015 011 008 011 UTS UTS UTS 014 008 002 LTS 014 014 013 013 007 UTE 013 012 012 UTE 013 004 014 007 012 014 007 009 012 014 014 UTS UTS 013 008 LTS UTS 013 011 009 010 010 UTE UTE 014 014 UTE UTE 010 010 010 010 010 010 015 010 012 014 014 UTE LTS 015 UTS UTS 014 UTS UTE LTS UTS 015 015 UTE 015

+0.73

+0.52

-6.99

-0.68

-0.70

-11.29

-11.05

-11.05

+1.08

+5.19

-10.06

+18.37

+0.79

+1.22

+9.82

+9.82

-0.68

-0.14

+0.95

+1.18

+1.44

-0.21

-0. 68

-0.66

+0.38

-0.79

+0.79

+16.46

-13.31

-0.74

-12.08

+1.21

+1.21

-14.37 TO-11.74

-14.37 TO-11.74

-0.77

+0.65

-0.05

+6.11

+15.88

+17.16

-0.50

+1.27

+1.27

-0.17

-0.13

-12.54

-12.54

-0.20

-0.12

+15.76

+15.76

+15.83

+15.83

+18.17

+18.17

+1.75

-13.56

-19.42

+0.52

+1.02

-0.17

-13.43

+1.82

-13.38

-13.38

+0.37

-9.41

-0.17

-13.46

-15.96

+0.89

+0.89

-0.14

+13.35 015 015 015 015 011 011 008 008 011 011 UTS UTS UTS UTS UTS UTS 014 014 008 008 002 002 LTS LTS 014 014 014 014 013 013 013 013 007 007 UTE UTE 013 013 012 012 012 012 UTE UTE 013 013 004 004 014 014 007 007 012 012 014 014 007 007 009 009 012 012 014 014 014 014 UTS UTS UTS UTS 013 013 008 008 LTS LTS UTS UTS 013 013 011 011 009 009 010 010 010 010 UTE UTE UTE UTE 014 014 014 014 UTE UTE UTE UTE 010 010 010 010 010 010 010 010 010 010 010 010 015 015 010 010 012 012 014 014 014 014 UTE UTE LTS LTS 015 015 UTS UTS UTS UTS 014 014 UTS UTS UTE UTE LTS LTS UTS UTS 015 015 015 015 UTE UTE 015 015 WAR WAR IDOK WAR WAR WAR WAR 4027 OUTLET 4022 OUTLET 4044 INLET 4046 INLET 4038 INLET 4059 OUTLET 4038 INLET 4038 INLET 4027 OUTLET 4054 INLET 4022 OUTLET 4034 OUTLET 4022 OUTLET 4022 OUTLET 4048 INLET 4048 INLET 4038 INLET 2031 INLET 4046 INLET 4046 INLET 4046 INLET 2058 INLET 4022 OUTLET 4022 OUTLET 4048 INLET 4046 INLET 4046 INLET 4037 OUTLET 4037 OUTLET 4045 OUTLET 4037 OUTLET 4045 OUTLET 4045 OUTLET 4045 OUTLET 4045 OUTLET 4015 OUTLET 4015 OUTLET 4037 OUTLET 4037 OUTLET 4037 OUTLET 4037 OUTLET 4051 INLET 4015 OUTLET 4015 OUTLET 2088 INLET 2088 INLET 4017 OUTLET 4017 OUTLET 2088 INLET 2089 INLET 4017 OUTLET 4017 OUTLET 4017 OUTLET 4017 OUTLET 4017 OUTLET 4017 OUTLET 4019 OUTLET 4037 OUTLET 4037 OUTLET 4037 OUTLET 4051 INLET 2089 INLET 4015 OUTLET 4019 OUTLET 4037 OUTLET 4037 OUTLET 4037 OUTLET 4037 OUTLET 2088 INLET 4015 OUTLET 4019 OUTLET 4045 OUTLET 4045 OUTLET 2008 INLET 4037 OUTLET 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460SI 4 60HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 4 60HR 460HR 460SI 460SI 460HR 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460SI 4 60HR 460SI WAR 74 2

74 2

18 2

27 2

123 2 114 2 16 2

29 2

29 2

98 2

92 2

92 2

81 2

81 2

104 2 46 2

54 2

139 2 78 2

16 2

189 1 78 2

42 2

42 2

30 2

64 2

16 2

166 1 48 2

92 2

91 2

17 2

47 2

VOL TWD 38 TEA TEA SAI TWD 13 TEA TEA SAI TWD 31 SAI TWD 37 SAI TWD 49 VOL VOL VOL VOL VOL TEA DNT VOL SAI TWD 88 VOL VOL TEA DNT VOL VOL TWD 0 TEA VOL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:29:49 Component: S/G A Page 8 of 31 ATTACHMENT #3 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 48 48 48 48 48 48 48 48 48 48 49 49 49 50 50 50 50 51 51 51 51 51 51 51 52 52 52 52 52 52 52 52 53 53 53 53 53 54 54 54 54 54 54 54 54 55 55 55 55 55 55 55 55 55 56 56 56 5 6 5 6 57 57 57 30 1.22 31 0.52 51 0.37 61 0.58 69 0.19 76 0.08 77 0.18 80 0.19 0.22 81 0.22 117 0.43 17 2.82 76 1.02 0.22 0.18 123 0.87 23 0.19 65 1.98 81 1.89 0.16 95 1.16 0.46 12 0.07 45 0.59 62 0.07 65 0.07 68 1.26 95 0.13 123 0.29 2

0.33 71 0.18 72 0.12 83 0.17 84 0.20 100 4.12 106 1.11 119 0.29 1

0.40 3

0.93 113 0.08 121 0.68 122 0.31 2

1.24 3

0.77 5

0.22 45 0.29 73 0.08 80 0.13 121 0.61 124 0.45 1

0.79 1.16 11 0.16 29 0.18 46 0.20 102 0.15 0.15 0.12 0.12 0.12 0.12 121 0.77 123 0.37 124 0.63 125 0.72 4

0.46 11 0.30 0.29 28 0.29 122 0.23 124 0.45 2

0.48 3

0.70 0.69 4

0.38 19 2

TEA 59 P 3 TWD 6 59 2

VOL 15 2

TEA 102 P 3 TWD 4 42 2

VOL 155 2 VOL 65 2

VOL 28 2

VOL 139 2 VOL 66 P 3 TWD 7 174 1 DNT 13 2

TEA 51 2

SAI 72 2

TWD 44 76 P 3 TWD 14 50 2

VOL 14 2

TEA 174 1 DNT 120 2 VOL 17 2

TEA 66 P 3 TWD 9 66 2

VOL 29 2

TEA 85 2

VOL 42 2

VOL 28 2

TEA 17 P 3 TWD 2 115 P 3 TWD 4 109 2 VOL 41 2

VOL 51 2

VOL 111 2 VOL 119 2 VOL 166 1 DNT 21 2

TEA 67 2

VOL 105 2 VOL 109 P 3 TWD 12 60 2

VOL 77 P 3 TWD 11 92 2

VOL 79 P 3 TWD 15 93 P 3 TWD 10 94 2

VOL 92 P 3 TWD 3 60 2

VOL 18 2

VOL 79 P 3 TWD 10 79 P 3 TWD 7 46 P 3 TWD 8 41 P 3 TWD 12 67 2

VOL 34 2

VOL 66 2

VOL 77 2

SAI 77 2

TWD 30 100 2 SAI 100 2 TWD 0 87 2

SAI 87 2

TWD 0 96 P 3 TWD 12 96 P 3 TWD 8 116 P 3 TWD 14 70 P 3 TWD 11 126 P 3 TWD 7 43 2

VOL 38 2

TWD 78 42 2

VOL 98 2

VOL 113 2 VOL 136 P 3 TWD 9 66 2

VOL 63 2

TWD 49 47 P 3 TWD 6 UTE 015 012 UTE 014 011 014 014 014 015 015 UTS UTE 012 012 011 015 UTE LTS 014 UTE 014 012 UTE 013 008 UTE 014 009 011 004 003 014 014 003 UTE 015 013 011 013 008 015 013 011 UTS 015 014 003 009 009 012 013 012 008 013 012 012 012 012 012 012 008 009 009 011 011 UTS UTS 002 011 010 013 014 014 012

-0.12

+0.47

+17.72

-0.15

+0.12

+12. 23

+0.32

+0.16

+0.65

+0.50

+0.77

+12.33

-0.28

-10.01

-10.01

+0.78

+4.85

-0.27

+0.18

+0.42

-0.24

+0.59

+8.36

-0.15

-4.76

-19.83

-0.28

+0.25

-0.70

+0.69

-11.82

-9.88

+0.11

+0.34

-3.64

-0.27

+0.22

-0. 64

+0.70

+17.82

-0.59

+0.32

-0.71

+0.73

-22.27

+0.73

-10.21

+8.14

-0.53

-0.73

-0.70

-0.61

-6.07

-5.10

-0.37

+13. 80

+13. 80

+15.03

+15.03

+15.95

+15.95

-0.65

-0.71

-0.71

-0.55

-0.72

+11.27

+11.27

-17.28

-0.80

+0.49

-0.75

+1.16

+1.16

+0.78 UTE UTE 015 015 012 012 UTE UTE 014 014 011 011 014 014 014 014 014 014 015 015 015 015 UTS UTS UTE UTE 012 012 012 012 011 011 015 015 UTE UTE LTS LTS 014 014 UTE UTE 014 014 012 012 UTE UTE 013 013 008 008 UTE UTE 014 014 009 009 011 011 004 004 003 003 014 014 014 014 003 003 UTE UTE 015 015 013 013 011 011 013 013 008 008 015 015 013 013 011 011 UTS UTS 015 015 014 014 003 003 009 009 009 009 012 012 013 013 012 012 008 008 013 013 012 012 012 012 012 012 012 012 012 012 012 012 008 008 009 009 009 009 011 011 011 011 UTS UTS UTS UTS 002 002 011 011 010 010 013 013 014 014 014 014 012 012 WAR WAR WAR WAR WAR WAR WAR 2089 INLET 4017 OUTLET 4019 OUTLET 2088 INLET 4045 OUTLET 4037 OUTLET 4037 OUTLET 4037 OUTLET 4037 OUTLET 4037 OUTLET 4051 INLET 4015 OUTLET 2008 INLET 4037 OUTLET 4037 OUTLET 4051 INLET 4017 OUTLET 2008 INLET 4037 OUTLET 4037 OUTLET 2008 INLET 4045 OUTLET 4015 OUTLET 2088 INLET 4019 OUTLET 4045 OUTLET 2008 INLET 4045 OUTLET 4051 INLET 4015 OUTLET 4045 OUTLET 4045 OUTLET 4037 OUTLET 4037 OUTLET 4045 OUTLET 2008 INLET 4051 INLET 4015 OUTLET 4015 OUTLET 4051 INLET 4051 INLET 4051 INLET 4015 OUTLET 4015 OUTLET 4015 OUTLET 4017 OUTLET 4045 OUTLET 4037 OUTLET 4051 INLET 4051 INLET 4015 OUTLET 4015 OUTLET 4015 OUTLET 4017 OUTLET 4017 OUTLET 4045 OUTLET 4045 OUTLET 4045 OUTLET 4045 OUTLET 4045 OUTLET 4045 OUTLET 4051 INLET 4051 INLET 4051 INLET 4051 INLET 4015 OUTLET 4015 OUTLET 4015 OUTLET 4017 OUTLET 4051 INLET 4051 INLET 4064 OUTLET 4015 OUTLET 4015 OUTLET 4015 OUTLET 460HR 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 4 60HR 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460HR 460SI 460SI 460HR 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 4 60HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:29:49 Component: S/G A Page 9 of 31 ATTACHMENT #3 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS 57 12 0.09 57 34 0.33 57 70 1.51 57 78 0.74 57 79 0.09 57 85 0.12 0.13 0.13 0.13 57 124 0.94 58 2

0.54 0.83 0.73 58 3

0.69 0.29 0.29 58 4

0.86 58 9

1.37 58 103 0.20 0.08 0.08 0.06 0.06 0.04 0.04 0.08 0.08 0.05 0.05 0.06 0.06 0.08 0.08 0.06 0.06 0.08 0.08 0.09 0.09 58 109 0.39 58 122 1.14 58 125 0.41 58 126 0.48 59 85 0.90 59 114 0.07 59 117 0.81 59 120 0.48 59 121 0.23 59 124 0.32 60 3

0.45 60 7

0.53 60 68 5.92 60 80 0.22 60 117 4.27 60 122 6.43 60 125 0.76 60 126 0.74 61 3

0.28 0.54 61 86 1.49 0.22 61 98 0.18 61 116 0.06 61 121 0.14 62 1

4.75 62 8

0.53 62 9

1.20 62 54 0.32 0.32 62 115 0.29 62 126 0.77 63 1

1.96 63 4

0.24 0.31 0.24 DEG 33 41 21 17 49 79 79 79 76 72 55 144 120 106 82 82 35 11 49 67 67 44 44 85 85 83 83 90 90 61 61 58 58 47 47 53 53 56 56 90 67 131 87 15 66 77 88 85 118 116 17 174 21 174 166 62 101 83 128 28 95 45 74 85 19 118 13 23 23 58 100 32 86 24 86 CHN 2

2 2

2 2

2 2

2 2

P 3 P 3 P 3 P 3 P 3 2

2 P 3 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

P 3 P 3 P 3 2

2 P 3 P 3 P 3 P 3 P 3 2

1 P 3 1

1 P 3 P 3 P 3 P3 2

2 2

2 2

P 1 P 3 2

2 2

2 P 3 P 1 2

2 2

IND VOL VOL TEA TEA VOL SAI SAI TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TEA VOL SAI TWD SAI TWD SAI TWD SAI TWO SAI TWD SAI TWD SAI TWD SAI TWD SAI TWD SAI TWO VOL TWD TWD TWD TEA VOL TWD TWD TWD TWD TWD TEA DNT TWO DNT DNT TWD TWD TWD TWD TEA VOL VOL VOL VOL DRS TWD TEA SAI TWD VOL TWO DRS VOL VOL TWO

%TW LOCATION EXT EXT UTIL 1 UTIL 2 005

-12.73 005 005 007

-6.28 007 007 UTE

-0.27 UTE UTE UTE

-0.23 UTE UTE 008

+2.88 008 008 015

-2.39 015 015 015

-3.12 015 015 29 015

-3.12 015 015 36 015

-2.39 015 015 15 009

-0.78 009 009 WAR 10 012

-0.72 012 012 WAR 15 013

-0.75 013 013 WAR 13 014

-0.72 014 014 WAR 12 011

-0.50 011 011 WAR 012

+1.01 012 012 18 012

+1.01 012 012 9

011

-0.63 011 011 WAR UTE

-0.17 UTE UTE 008

-5.61 008 008 011

-1.53 011 011 85 011

-1.53 011 011 011

+5.27 011 011 94 011

+5.27 011 011 011

+7.35 011 011 76 011

+7.35 011 011 011

+8.48 011 011 77 011

+8.48 011 011 011

+9.85 011 011 74 011

+9.85 011 011 011

+14.22 011 011 88 011

+14.22 011 011 011

+16.43 011 011 89 011

+16.43 011 011 011

+17.86 011 011 93 011

+17.86 01i 011 011

+18.88 011 011 91 011

+18.88 011 011 011

+21.11 011 011 90 011

+21.11 011 011 015

+10.10 015 015 16 009

-0.62 009 009 WAR 9

009

-0.71 009 009 WAR 8

011

-0.71 011 011 WAR UTE

-0.25 UTE UTE 010

-11.44 010 010 12 009

-0.74 009 009 WAR 11 009

-0.80 009 009 WAR 4

010

+0.42 010 010 WAR 7

011

-0.67 011 011 WAR 8

011

-0.72 011 011 WAR UTE

-0.19 UTE UTE UTS

+11.35 UTE UTS 4

005

+0.61 005 005 WAR 003

-3.12 003 003 005

-4.22 005 005 11 009

-0.60 009 009 WAR 11 009

-0.71 009 009 WAR 5

011

-0.62 011 011 WAR 10 013

-0.76 013 013 WAR UTE

-0.22 UTE UTE 015

+0.93 015 015 015

+9.77 015 015 015

+14.58 015 015 014

+1.30 014 014 UTE

-0.94 UTE UTE SLV 6

010

+0.50 010 010 WAR UTE

-0.18 UTE UTE UTE

-1.19 UTE UTE TR 66 UTE

-1.19 UTE UTE 004

-7.51 004 004 15 009

-0.70 009 009 WAR UTE

-0.84 UTE UTE SLV 012

+0.78 012 012 012

+1.06 012 012 1

012

+0.78 012 012 CAL #

4015 4017 2015 2015 4045 4037 4037 4037 4037 4051 4066 4064 4064 4064 4064 4064 4015 2085 4042 4042 4042 4042 4042 4042 4042 4042 4042 4042 4042 4042 4042 4042 4042 4042 4042 4042 4042 4042 4042 4045 4051 4051 4051 2019 4051 4051 4051 4051 4053 4064 2085 4002 4045 4051 4051 4051 4051 4064 4064 2020 4042 4045 4051 4051 1004 4013 2079 2079 2079 4051 4053 1004 4064 4064 4064 LEG OUTLET OUTLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET INLET OUTLET INLET INLET INLET INLET OUTLET OUTLET INLET OUTLET OUTLET INLET INLET INLET OUTLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET PROBE 460SI 460SI 460HR 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460SI 40OPS 460SI 460HR 460HR 460HR 460SI 460SI 400PS 460SI 460SI 460SI

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:29:49 Component: S/G A Page 10 of 31 ATTACHMENT #3 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS 0.31 63 61 0.08 63 89 0.12 63 94 2.84 63 127 1.88 64 2

0.82 64 3

3.87 64 12 0.93 0.13 64 48 0.24 64 126 0.60 65 3

0.32 65 18 0.31 65 125 0.92 65 126 0.08 0.08 66 3

0.23 66 45 0.33 66 126 0.63 0.78 67 2

8.63 0.26 67 7

0.34 67 11 0.24 67 35 1.29 67 37 0.44 67 68 0.12 67 124 0.76 68 2

4.19 0.37 0.32 68 5

0.54 68 6

0.26 68 11 0.31 68 12 0.31 68 13 0.41 0.23 68 20 0.93 68 23 1.30 68 66 0.60 68 100 0.25 68 110 0.37 0.24 68 117 0.57 0.56 68 127 1.65 0.29 0.97 68 129 0.19 68 130 0.45 69 6

0.34 69 12 0.59 69 14 0.09 69 15 0.37 0.16 69 41 0.81 69 43 0.43 69 44 0.16 0.52 69 46 0.67 69 74 6.72 69 78 0.16 0.16 0.14 0.14 69 83 1.52 69 118 0.07 70 3

0.53 0.29 70 7

3.21 5.77 2.64 0.56 70 8

0.50 0.35 DEG CHN 24 2

27 2

57 2

352 1 26 2

97 P 3 22 P 1 12 2

69 2

75 2

92 P 3 143 P 3 118 2 98 P 3 81 2

81 2

52 2

143 2 86 P 3 98 P 3 26 P 1 78 2

134 2 118 2 19 2

110 P 3 54 2

108 P 3 22 P 1 123 P 3 136 P 3 98 P 3 98 2

14 P 3 65 P 3 22 P 3 57 2

131 P 3 107 P 3 84 P 3 134 P 3 36 2

58 2

52 2

52 2

26 2

117 P 3 59 P 3 132 P 3 92 P 3 90 2

18 P 3 136 2 38 P 3 89 2

70 P 3 141 P 3 192 P 3 40 P 3 24 P 3 150 1 63 2

63 2

65 2

65 2

29 2

21 2

97 P 3 77 P 3 23 P 1 21 P 1 22 P 1 96 P 3 129 P 3 110 P 3 IND TWD VOL VOL DNT TEA TWD DRS TEA VOL VOL TWD TWD VOL TWD SAI TWD VOL VOL TWD TWD DRS VOL VOL VOL TEA TWD VOL TWD DRS TWD TWD TWD VOL TWD TWD TWD VOL TWD TWD TWD TWD VOL TWD VOL TWD TEA TWD TWD TWD TWD VOL TWD VOL TWD VOL TWD TWD TWD TWD TWD DNT SAI TWD SAI TWD TEA VOL TWD TWD DRS DRS DRS TWD TWD TWD

%TW LOCATION EXT EXT UTIL 1 UTIL 2 80 012

+1.06 012 012 014

+0.16 014 014 012

+10.72 012 012 LTS

+0.27 LTS LTS UTE

-0.15 UTE UTE 14 011

+0.58 011 011 WAR UTE

-0.90 UTE UTE SLV UTE

-0.17 UTE UTE UTS

-0.36 UTS UTS 009

-10.72 009 009 14 009

-0.65 009 009 WAR 6

013

-0.71 013 013 WAR 004

-0.67 004 004 13 008

-0.61 008 008 WAR 014

-4.86 014 014 40 014

-4.86 014 014 011

-0.68 011 011 006

+0.68 006 006 10 008

-0.66 008 008 WAR 8

008

+0.64 008 008 WAR UTE

-0.89 UTE UTE SLV 011

-0.72 011 011 004

-0.71 004 004 012

+0.62 012 012 UTE

-0.18 UTE UTE 10 009

+0.68 009 009 WAR 015

+10.30 015 015 14 007

-0.37 007 007 WAR UTE

-0.87 UTE UTE SLV 6

011

+0.57 011 011 WAR 6

011

-0.76 011 011 WAR 10 010

+0.58 010 010 WAR 010

+0.59 010 010 7

010

-0.73 010 010 WAR 7

010

-0.61 010 010 WAR 10 010

-0.60 010 010 WAR 011

+0.62 011 011 10 008

-0.67 008 008 WAR 13 010

-0.71 010 010 WAR 9

004

+0.79 004 004 WAR 5

015

+0.65 015 015 WAR 006

+11.32 006 006 77 006

+11.32 006 006 014

+0.75 014 014 71 014

+0.75 014 014 UTE

-0.17 UTE UTE 6

008

+0.63 008 008 WAR 19 008

-0.66 008 008 WAR 4

007

+0.58 007 007 WAR 9

011

-0.36 011 011 WAR 011

-2.25 TO-1.39 011 011 9

010

-0.54 010 010 WAR UTS

-0.30 UTS UTS 6

008

-0.64 008 008 WAR 015

+1.60 015 015 9

008

+0.73 008 008 WAR 5

006

+0.67 006 006 WAR 2

006

+0.70 006 006 WAR 6

009

-0.71 009 009 WAR 8

006

+0.68 006 006 WAR 009

+21.67 010 009 013

+3.27 013 013 69 013

+3.27 013 013 013

+6.78 013 013 65 013

+6.78 013 013 UTE

-0.17 UTE UTE 015

+3.05 015 015 10 011

-0.26 011 011 WAR 5

011

+0.38 011 011 WAR UTE

-0.90 UTE UTE SLV 015

-5.14 015 015 SLV 015

-7.26 015 015 SLV 10 010

+0.38 010 010 WAR 9

011

+0.60 011 011 WAR 6

013

-0.52 013 013 WAR CAL #

4064 4002 4042 4042 2073 4064 1004 2079 4015 4019 4051 4064 4013 4051 4051 4051 4064 4017 4061 4061 1004 4064 4015 4015 2079 4017 4002 4053 1004 4064 4064 4064 4064 4015 4015 4015 4015 4013 4013 4002 4045 4045 4045 4053 4053 2074 4053 4053 4053 4053 4064 4015 4015 4015 4015 4017 4017 4017 4017 4017 4002 4045 4045 4045 4045 2023 4053 4064 4064 1002 1002 1002 4064 4064 4064 LEG OUTLET INLET OUTLET OUTLET INLET OUTLET INLET INLET OUTLET OUTLET INLET OUTLET OUTLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET INLET OUTLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET INLET INLET OUTLET OUTLET INLET INLET INLET OUTLET OUTLET OUTLET PROBE 460SI 460SI 460SI 460SI 4 60HR 460SI 400PS 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 400PS 460SI 460SI 460SI 460HR 460SI 460SI 460SI 400PS 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460SI 400PS 400PS 400PS 460SI 460SI 460SI

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:29:49 Component: SIG A Page 11 of 31 ATTACHMENT #3 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW 7=0 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 71 71 71 71 71 71 71 71 71 71 71 71 71 71 71 71 71 71 71 71 71 71 71 71 71 71 72 72 72 72 72 72 72 72 TUBE VOLTS 9

0.51 10 0.74 11 0.20 0.15 12 0.94 13 0.30 0.25 18 0.37 0.37 22 0.45 24 1.18 43 1.13 0.51 45 0.84 46 0.93 0.48 0.47 53 0.30 66 0.66 95 2.88 6.40 6.43 3.51 2.16 3.39 6.93 124 0.25 0.08 128 0.73 1

7.84 2.71 3

2.07 9

0.81 12 0.19 13 0.52 0.59 14 1.45 0.70 15 0.54 17 1.31 1.42 18 0.24 21 0.22 23 0.34 28 0.38 0.38 30 0.32 33 0.70 36 0.33 45 0.37 46 0.50 0.43 0.88 48 0.62 54 0.42 71 0.10 95 2.14 96 0.14 0.14 101 0.27 106 11.66 13.67 119 0.07 131 0.33 1

3.22 3.04 3.05 7

3.15 8

2.66 13 0.33 24 0.71 0.66 25 0.98 31 0.40 34 0.41 DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 137 103 125 126 60 97 101 0

40 96 107 47 128 53 97 117 118 27 113 172 176 180 187 179 179 181 72 42 75 25 22 16 119 48 130 60 0

26 24 74 63 10 89 128 129 152 145 88 122 60 59 34 76 82 136 56 188 78 78 62 170 173 44 41 21 24 20 24 21 154 122 121 67 128 0

P 3 TWD 9 P 3 TWD 11 2

VOL 2

VOL P 3 TWD 14 2

VOL 2

VOL P 3 TWD 6 P 3 TWD 6 2

VOL P 3 TWD 12 P 3 TWD 13 P 3 TWD 6 P 3 TWD 10 P 3 TWD 11 P 3 TWD 11 P 3 TWD 11 P 3 TWD 4 P 3 TWD 10 1

DNT 1

DNT 1

DNT 1

DNT 1

DNT 1

DNT 1

DNT 2

VOL 2

VOL P 3 TWD 15 P 1 DRS P 1 DRS P 1 DRS P 3 TWD 14 2

VOL P 3 TWD 8 P 3 TWD 9 P 3 TWD 14 P 3 TWD 11 P 3 TWD 6 P 3 TWD 14 P 3 TWD 14 P 3 TWD 4 2

VOL 2

VOL 2

VOL 2

VOL 2

VOL P 3 TWD 8 2

VOL P 3 TWD 5 P 3 TWD 6 P 3 TWD 5 P 3 TWD 10 P 3 TWD 7 P 3 TWD 5 2

VOL 1

DNT 2

SAI 2

TWD 25 2

VOL 1

DNT 1

DNT 2

VOL 2

VOL P 1 DRS P 1 DRS P 1 DRS P 1 DRS P 1 DRS P 3 TWD 6 P 3 TWD 7 P 3 TWD 4 P 3 TWD 10 2

VOL P 3 TWD 6 010 009 012 012 013 011 011 015 015 011 003 008 009 009 008 009 009 005 005 LTE LTE LTE LTE LTE LTE LTE 003 002 008 UTE 015 UTE 011 014 010 014 015 015 014 015 015 008 012 011 012 013 012 012 011 008 006 007 008 009 005 010 UTS 013 013 011 005 005 001 015 UTE 015 015 UTE UTE 014 015 015 013 012 015

+0.57

+0.66

-1.45

-3.77

-0.70

+36. 89

+0.76

-0.78

-0.74

+0.53

+0.16

+0.69

-0.74

-0.68

-0. 67

+0.62

-0.72

+0.63

+0.50

+1.84

+2.47

+3.11

+3.88

+4.56

+9.83

+2.74

-4.54

+9.77

-0.64

-0.92

-7.08

-0.90

+0.73

-0.64

+0.55

-0. 68

-0.78

-0.68

-0.69

-0.71

-0. 69

+0.71

+2.3 6

+0.59

+0.50

+0. 65

+0.47

+0. 64

+0.54

+0.5 6

+0. 68

-0.64

-0.73

-0.66

+0.57

+24.12

-14.24

+14.73

+14.73

-4.41

-1.83

-5. 99

+8. 68

-1.86

-0.87

-4.80

-7.03

-0.91

-0. 90

+0.66

+0.67

+0.64

+0.64

+0.24

-0.42 010 009 012 012 013 011 011 015 015 011 003 008 009 009 008 009 009 005 005 LTE LTE LTE LTE LTE LTE LTE 003 002 008 UTE 015 UTE 011 014 010 014 015 015 014 015 015 008 012 011 012 013 012 012 011 008 006 007 008 009 005 011 UTS 013 013 011 005 005 001 015 UTE 015 015 UTE UTE 014 015 015 013 012 015 010 009 012 012 013 012 012 015 015 011 003 008 009 009 008 009 009 005 005 LTS LTS LTS LTS LTS LTS LTS 003 002 008 UTE 015 UTE 011 014 010 014 015 015 014 015 015 008 012 011 012 013 012 012 011 008 006 007 008 009 005 010 UTS 013 013 011 005 005 001 015 UTE 015 015 UTE UTE 014 015 015 013 012 015 WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR SLV SLV SLV WAR WAR WAR WAR WAR WAR WAR WAR WAR 4064 4015 4015 4015 4015 4015 4015 906 4015 4013 4013 4017 4017 4017 4017 4017 4017 4019 4002 4042 4042 4042 4042 4042 4042 4042 4053 4053 4053 1004 1004 1003 4064 4015 4015 4015 905 4015 4015 905 4015 4015 4013 4013 4017 4017 4017 4017 4017 4019 4019 4019 4019 4019 4019 4002 4045 4045 4045 4045 4045 4045 4053 4053 1004 1004 1004 1002 1002 4064 4013 903 4013 4017 902 OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET INLET OUTLET OUTLET INLET 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460LW 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 400PS 400PS 40OPS 460SI 460SI 460SI 460SI 46OLW 460SI 460SI 4 6OLW 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 400PS 400PS 400PS 400PS 400PS 460SI 460SI 4 6OLW 460SI 460SI 4 6OLW WAR WAR WAR WAR WAR WAR WAR SLV SLV SLV SLV SLV WAR WAR WAR WAR WAR

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:29:49 Component: S/G A Page 12 of 31 ATTACHMENT #3 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS 0.63 72 35 0.42 0.75 72 39 0.74 72 53 0.38 0.39 72 64 0.41 72 69 2.96 72 72 0.10 0.10 0.04 0.09 0.10 0.04 0.09 0.10 0.13 0.10 0.11 0.12 0.11 0.11 72 79 0.07 72 101 1.10 72 127 0.62 73 2

1.27 73 4

0.88 0.83 73 5

0.67 73 7

1.69 73 8

2.00 2.17 73 35 0.84 73 46 0.30 73 48 0.28 73 65 0.14 73 66 0.15 0.20 73 94 1.49 73 98 0.14 73 120 0.09 73 129 2.52 74 1

8.27 74 3

4.27 4.38 74 5

4.09 74 6

2.25 74 7

2.79 74 11 1.98 74 19 0.20 74 23 4.07 4.07 1.69 1.69 74 29 1.82 74 48 0.17 74 59 3.35 74 91 2.10 74 112 0.06 74 117 5.79 74 125 0.76 4.79 75 1

4.67 75 4

4.77 7.78 75 8

2.07 75 9

3.93 4.13 75 46 5.47 4.75 8.68 75 65 2.34 75 101 0.10 75 112 0.13 75 117 3.83 DEG CHN IND %Tl 108 P 3 TWD 7 0

P 3TWD 6 67 P 3 TWD 9 62 P 3TWD 8 83 P 3 TWD 5 99 P 3 TWD 5 37 P 3 TWD 6 11 1

DNT 70 2

VOL 71 2

TWD 46 79 2

VOL 111 2 VOL 76 2

VOL 79 2

TWD 39 111 2 TWD 13 76 2

TWD 42 65 2

VOL 66 2

VOL 67 2

VOL 67 2

TWD 50 66 2

TWD 51 67 2

TWD 50 36 2

VOL 46 2

TEA 86 P 3 TWD 13 11 P 1 DRS 25 P 1 DRS 101 P 3 TWD 14 68 P 3 TWD 12 21 P 1 DRS 27 P 1 DRS 44 P 1 VOL 18 2

TEA 41 P 3 TWD 4 143 P 3 TWD 3 101 2 VOL 55 2

VOL 60 2

TWD 57 180 1 DNT 53 2

VOL 47 2

VOL 25 2

TEA 27 P 1 DRS 28 P 1 DRS 346 1 DNT 26 P 1 DRS 27 P 1 DRS 25 P 1 DRS 20 P 1 DRS 145 P 3 TWD 3 28 P 1 MAI 28 P 1 TWD 53 29 P 1 SAI 29 P 1 TWD 56 22 P 1 DRS 81 2

VOL 155 1 DNT 179 1 DNT 46 2

VOL 156 1 DNT 130 P 3 TWD 15 340 1 DNT 26 P 1 DRS 21 P 1 DRS 177 1 DNT 25 P 1 DRS 25 P 1 DRS 20 P 1 DRS 168 1 DNT 181 1 DNT 172 1 DNT 23 2

TEA 62 2

VOL 73 2

VOL 161 1 DNT I

LOCATION 015

-0.45 015

-0.57 015

-0.56 012

+0.51 005

-0.64 007

-0.72 003

+0.57 002

+23.21 007

+28.26 007

+28.26 008

+16.07 008

+18.06 008

+35.64 008

+16.07 008

+18.06 008

+35.64 009

+1.29 009

+6.18 009

+12.06 009

+1.29 009

+6.18 009

+12.06 015

-5.43 UTE

-0.28 008

-0.83 UTE

-0.78 UTE

-0.73 013

-0.44 014

-0.85 UTE

-0.91 UTE

-0.86 015

-0.07 UTE

-0.18 010

+0.59 009

+0.52 014

+6.11 LTS

+31.21 LTS

+31.21 LTE

+5.79 001

-6.96 015

-13.24 UTE

-0.21 UTE

-0.91 UTE

-1.01 LTS

-12.41 UTE

-0.87 UTE

-0.91 UTE

-0.88 UTE

-0.87 009

-0.25 015

-3.91 015

-3.91 015

-5.75 015

-5.75 UTE

-0.94 001

+16.84 LTE

+5.63 LTS

+0.20 012

-8.29 LTS

-12.91 010

+0.52 LTS

-12.85 UTE

-0.92 UTE

-0.95 LTS

-13.02 UTE

-0.89 UTE

-0.87 015

-4.93 LTS

-0.13 LTS

+3.71 LTS

+8.62 UTE

-0.23 012

+3.27 010

+2.20 LTS

-13.00 EXT 015 015 015 012 005 007 003 003 008 007 009 009 009 009 009 009 010 010 010 010 010 010 015 UTE 008 UTE UTE 013 014 UTE UTE 015 UTE 010 009 015 001 001 LTE 001 015 UTE UTE UTE LTS UTE UTE UTE UTE 009 015 015 015 015 UTE 001 LTS LTS 012 LTS 010 LTS UTE UTE LTS UTE UTE 015 LTS LTS LTS UTE 012 010 LTS EXT UTIL 1 015 WAR 015 WAR 015 WAR 012 WAR 005 WAR 007 WAR 003 WAR 002 007 007 008 008 008 008 008 008 009 009 009 009 009 009 015 UTE 008 WAR UTE SLV UTE SLV 013 WAR 014 WAR UTE SLV UTE SLV 015 SLV UTE 010 WAR 009 WAR 014 LTS LTS LTS 001 015 UTE UTE SLV UTE SLV LTS UTE SLV UTE SLV UTE SLV UTE SLV 009 WAR 015 SLV 015 015 SLV 015 UTE 001 LTE LTS 012 LTS 010 WAR LTS UTE SLV UTE SLV LTS UTE SLV UTE SLV 015 SLV LTS LTS LTS UTE 012 010 LTS UTIL 2 CAL #

4017 902 4017 4017 4019 4019 4002 4002 4002 4002 4002 4002 4002 4002 4002 4002 4002 4002 4002 4002 4002 4002 4045 2023 4053 1004 1015 4064 4064 1002 1002 1002 2080 4019 4019 4002 4002 4002 4045 4045 4053 2074 1004 1003 4064 1002 1002 1002 1002 4064 1001 1001 1001 1001 1001 4019 4002 4045 4053 4053 4053 4053 1004 1003 4064 1002 1002 1002 4019 4019 4019 2003 4045 4053 4053 LEG PROBE OUTLET 460SI INLET 460LW OUTLET 460SI OUTLET 460SI OUTLET 460SI OUTLET 460SI INLET 460SI INLET 460SI INLET 460SI INLET 460SI INLET 460SI INLET 460SI INLET 460SI INLET 460SI INLET 460SI INLET 460SI INLET 460SI INLET 460SI INLET 460SI INLET 460SI INLET 460SI INLET 460SI OUTLET 460SI INLET 460HR INLET 460SI INLET 400PS INLET 400PS OUTLET 460SI OUTLET 460SI INLET 400PS INLET 400PS INLET 400PS INLET 460HR OUTLET 460SI OUTLET 460SI INLET 460SI INLET 460SI INLET 460SI OUTLET 460SI OUTLET 460SI INLET 460SI INLET 460HR INLET 400PS INLET 400PS OUTLET 460SI INLET 400PS INLET 400PS INLET 400PS INLET 400PS OUTLET 460SI INLET 400PS INLET 400PS INLET 400PS INLET 400PS INLET 400PS OUTLET 460SI INLET 460SI OUTLET 460SI INLET 460SI INLET 460SI INLET 460SI INLET 460SI INLET 400PS INLET 400PS OUTLET 460SI INLET 400PS INLET 400PS INLET 400PS OUTLET 460SI OUTLET 460SI OUTLET 460SI INLET 460HR OUTLET 460SI INLET 460SI INLET 460SI

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:29:49 Component: S/G A Page 13 of 31 ATTACHMENT #3 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS 75 119 0.21 0.18 6.61 75 123 0.31 75 126 0.38 0.16 76 87 0.17 76 116 3.41 5.99 76 117 3.18 5.63 76 123 0.82 77 1

2.38 12.21 77 2

4.37 77 7

1.68 77 8

2.34 77 9

2.27 9.76

8. 65 77 72 0.07 0.07 0.14 0.14 0.10 0.10 0.09 0.09 0.07 0.07 77 112 0.12 77 115 0.07 0.32 77 119 0.20 0.22 77 125 0.78 78 2

5.08 7.67 78 6

3.08 78 9

2.54 78 11 0.11 78 12 4.10 78 15 2.05 78 16 1.44 78 26 4.18 78 28 1.98 1.91 78 29 2.72 78 61 2.25 78 81 0.89 78 91 0.13 0.13 78 101 0.49 78 102 1.38 78 116 0.12 78 117 0.08 78 120 0.18 0.19 78 121 0.13 0.09 78 125 0.50 5.99 79 1

2.52 79 3

2.45 79 4

0.77 0.39 0.17 4.74 79 6

3.70 4.01 0.50 0.78 1.20 79 8

2.45 2.23 DEG 121 78 349 76 70 81 67 339 339 150 163 119 16 180 182 23 20 26 172 172 96 96 75 75 65 65 70 70 61 61 69 98 41 80 94 95 14 182 20 21 55 171 22 25 17 25 23 19 26 22 74 74 89 162 72 129 92 92 110 82 42 195 36 7

102 155 83 169 19 176 64 115 106 19 19 CHN 2

2 1

2 2

2 2

22 1

1 P1 P1 P 1 1

2 2

2 2

2 2

2 2

2 2

2 2

2 2

P1 P1 P1 2

1 1

P 1 P 1 2

1 P 1 P 1 2

2 2

2 2

1 2

2 2

2 2

2 2

P3 1

2 P1 P1 2

2 1

P1 1

2 P1 P1 P1 2

2 1

2 P 3 P 1 P 1 IND VOL VOL DNT VOL VOL VOL VOL DNT DNT DNT DNT TWD DRS DNT DNT DRS DRS DRS DNT DNT SAI TWD SAI TWD SAI TWD SAI TWD SAI TWD VOL VOL TWD VOL TWD TWD DRS DNT DRS DRS VOL DNT DRS DRS DRS DRS DRS DRS TEA TEA SAI TWD VOL DNT VOL VOL VOL TWD VOL TWD TWD DNT PVN DRS VOL VOL VOL DNT DRS DNT VOL TWD TWD DRS DRS

%TW LOCATION EXT EXT 014

+0.93 014 014 014

+0.83 014 014 LTS

-13.48 LTS LTS 009

-0.58 009 009 015

+22.62 015 015 013

+1.12 013 013 001

-6.08 001 001 LTS

-13.25 LTS LTS UTS

+12.43 UTE UTS LTS

-13.19 LTS LTS UTS

+12.35 UTE UTS 15 010

+0.46 010 010 UTE

-0.78 UTE UTE LTS

+0.79 LTS LTS LTS

-13.10 LTS LTS UTE

-0.72 UTE UTE UTE

-0.80 UTE UTE UTE

-0.80 UTE UTE LTS

+2.30 LTS LTS LTS

+2.63 LTS LTS 012

+23.16 013 012 34 012

+23.16 013 012 012

+21.22 013 012 53 012

+21.22 013 012 012

+18.83 013 012 69 012

+18.83 013 012 012

+13.58 013 012 61 012

+13.58 013 012 012

+10.82 013 012 74 012

+10.82 013 012 013

-6.35 013 013 014

+1.36 014 014 81 014

+1.36 014 014 014

+1.06 014 014 14 014

+1.06 014 014 11 009

+0.07 009 009 UTE

-0.85 UTE UTE LTS

-13.35 LTS LTS UTE

-0.82 UTE UTE UTE

-0.81 UTE UTE 006

-4.37 006 006 013

-8.07 013 013 UTE

-0.81 UTE UTE UTE

-0.84 UTE UTE UTE

-0.77 UTE UTE 015

-6.47 015 015 015

-4.37 015 015 015

-4.60 015 015 UTE

-0.19 UTE UTE UTE

-0.29 UTE UTE 010

-15.08 010 010 46 010

-15.08 010 010 014

+1.32 014 014 LTS

-14.51 LTS LTS 014

+1.53 014 014 UTS

+0.69 UTS UTS 014

+1.16 014 014 17 014

+1.16 014 014 014

+0.88 014 014 30 014

+0.88 014 014 7

008

-0.48 008 008 009

-0.26 009 009 UTE

-1.52 UTE UTE UTE

-0.95 UTE UTE UTE

-0.83 UTE UTE 014

+0.81 014 014 014

-0.65 014 014 LTE

+10.54 LTE LTS UTE

-0.72 UTE UTE LTS

-13.10 LTS LTS 012

-0.53 012 012 13 013

-0.75 013 013 19 014

-0.66 014 014 UTE

-0.80 UTE UTE UTE

-0.79 UTE UTE UTIL 1 UTIL 2 WAR SLV SLV SLV SLV WAR SLV SLV SLV SLV SLV SLV SLV SLV SLV WAR SLV SLV SLV WAR WAR SLV IDOK CAL #

4053 4053 4053 4053 4053 4053 4053 4053 4053 4053 4053 1007 4063 4063 1006 1006 1006 4063 4063 4003 4003 4003 4003 4003 4003 4003 4003 4003 4003 4026 4026 4026 4026 4026 4028 1007 4063 1006 1006 4063 4063 1012 1012 1014 1014 1014 1014 2004 2025 4023 4023 4023 4023 4026 4043 4026 4026 4026 4026 4028 4028 1007 1007 1007 4063 4063 4066 1006 4063 4063 4063 4063 1006 1012 LEG INLET INLET INLET INLET INLET INLET OUTLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET INLET INLET INLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET INLET INLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET INLET INLET PROBE 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 400PS 460SI 460SI 400PS 400PS 400PS 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 400PS 460SI 400PS 400PS 460SI 460SI 400PS 400PS 400PS 400PS 400PS 400PS 460HR 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 400PS 40OPS 400PS 460SI 460SI 460SI 400PS 460SI 460SI 460SI 460SI 400PS 400PS

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:29:50 Component: S/G A Page 14 of 31 ATTACHMENT #3 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS 79 9

3.70 79 12 2.56 15.19 79 16 15.33 79 45 0.17 0.17 0.15 0.15 79 49 0.27 79 62 0.95 0.14 0.14 79 82 0.19 0.19 79 88 3.30 79 95 0.04 0.04 79 104 7.04 79 114 0.11 79 117 0.43 79 118 0.29 79 123 0.10 0.10 0.12 0.12 0.10 0.10 79 127 0.59 80 1

5.73 80 2

3.64 0.23 0.23 80 5

1.15 0.55 80 8

3.10 0.38 80 9

0.29 80 10 0.25 80 12 0.69 80 13 0.18 1.19 80 18 0.36 80 26 0.85 80 27 0.38 0.38 80 29 0.40 0.34 0.50 80 36 0.31 80 37 0.43 0.31 0.38 80 39 1.28 80 40 0.21 80 42 0.41 80 48 0.28 80 49 0.33 80 50 0.46 80 85 0.11 0.11 80 97 3.68 80 122 1.17 80 130 0.33 81 4

1.13 0.34 1.68 81 5

1.16 81 6

1.39 1.13 0.57 81 7

3.62 81 9

0.48 0.29 81 10 0.58 81 11 0.48 DEG 23 18 176 10 72 72 61 61 153 23 79 79 81 81 177 111 111 170 72 67 25 77 77 75 75 103 103 106 18 20 35 35 70 133 31 139 57 92 126 77 114 62 126 48 48 116 89 143 87 140 157 154 101 98 146 164 157 131 99 99 173 18 146 30 101 121 105 13 118 123 19 90 54 70 118 CHN P1I P 1 P1 2

2 2

2 P3 2

2 2

2 2

2 2

1 2

2 2

2 2

2 2

22 2

P 1

P 1 2

2 P 3 P 3 P 1 2

P 3 2

P 3 2

P 3 1P 3 1

2 23 2

P 3 2

P 3 P 3 P 3 1

2 P 3 P 3 P 3 P 3 2

2 1

2 P 3 P 1 P 3 P 3 1

P 1 P 3 P 3 P 1 P 3 P 3 P 3 P 3 IND DRS DRS DNT DNT SAI TWD SAI TWD TWD TEA SAI TWD SAI TWD DNT SAI TWD DNT VOL VOL VOL SAI TWD SAI TWD SAI TWD VOL DRS DRS SAI TWD TWD TWD DRS VOL TWD VOL TWD VOL TWD TWD VOL SAI TWD TWD VOL TWD VOL TWD TWD TWD VOL VOL TWD TWD TWD TWD SAI TWD DNT TEA TWD DRS TWD TWD VOL DRS TWD TWD DRS TWD TWD TWD TWD

%TW LOCATION EXT EXT UTIL 1 UTIL 2 UTE

-0.79 UTE UTE SLV UTE

-0.85 UTE UTE SLV 014

+0.35 014 014 014

+0.25 014 014 015

+16.87 015 015 57 015

+16.87 015 015 015

+17.27 015 015 73 015

+17.27 015 015 6

009

-0.71 009 009 WAR UTE

-0.19 UTE UTE 015

+41.06 UTS 015 44 015

+41.06 UTS 015 010

-3.76 010 010 39 010

-3.76 010 010 006

+17.87 006 006 010

+11.07 010 010 12 010

+11.07 010 010 003

-4.22 003 003 001

-13.65 001 001 007

-11.80 007 007 015

+0.50 015 015 015

-14.26 015 015 17 015

-14.26 015 015 015

-7.32 015 015 25 015

-7.32 015 015 015

-4.59 015 015 1

015

-4.59 015 015 014

+0.68 014 014 UTE

-0.81 UTE UTE SLV UTE

-0.86 UTE UTE SLV 012

-7.53 012 012 93 012

-7.53 012 012 19 012

-0.72 012 012 WAR 9

014

+0.59 014 014 WAR UTE

-0.82 UTE UTE SLV 004

-0.69 004 004 5

014

-0.72 014 014 WAR 014

-0.72 014 014 12 014

-0.56 014 014 WAR 012

+0.53 012 012 19 014

-0.47 014 014 WAR 7

014

+0.55 014 014 WAR 015

+17.41 015 015 UTS

-0.05 UTS UTS 93 UTS

-0.05 UTS UTS 10 015

+0.69 015 015 WAR 015

+16.36 015 015 8

015

+0.68 015 015 WAR 015

+13.28 015 015 9

014

+0.71 014 014 WAR 7

014

-0.14 014 014 WAR 9

014

-0.60 014 014 WAR 015

+14.73 015 015 015

+15.32 015 015 9

014

-0.70 014 014 WAR 6

009

-0.69 009 009 WAR 7

009

-0.68 009 009 WAR 10 009

-0.64 009 009 WAR 010

+1.06 010 010 22 010

+1.06 010 010 LTS

+0.04 LTS LTS UTE

-0.17 UTE UTE 5

010

+0.55 010 010 WAR UTE

-0.82 UTE UTE SLV 6

012

-0.55 012 012 WAR 25 013

-0.61 013 013 WAR 011

-1.96 011 011 UTE

-0.84 UTE UTE SLV 18 012

-0.63 012 012 WAR 10 013

+0.55 013 013 WAR UTE

-0.80 UTE UTE SLV 9

013

-0.73 013 013 WAR 5

014

-0.63 014 014 WAR 10 013

-0.77 013 013 WAR 8

013

-0.76 013 013 WAR CAL #

1006 1011 4063 4063 4047 4047 4047 4047 4047 2004 4003 4003 4023 4023 4023 4023 4023 4024 4026 4026 4024 4024 4024 4024 4024 4024 4024 4024 1007 1007 4063 4063 4063 4063 1007 4063 4063 4063 4063 4063 4063 4063 4041 903 903 4041 4041 903 4047 4047 4047 4047 4047 4047 4047 4047 4047 4047 4023 4023 4023 2070 4028 1007 4063 4063 4063 1007 4063 4063 1007 4063 4063 4063 4063 LEG INLET INLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET INLET OUTLET INLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET PROBE 400PS 400PS 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 400PS 400PS 460SI 460SI 460SI 460SI 400PS 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 46OLW 460LW 460SI 460SI 46OLW 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460SI 400PS 460SI 460SI 460SI 400PS 460SI 460SI 400PS 460SI 460SI 460SI 460SI

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:29:50 Component: S/G A Page 15 of 31 ATTACHMENT #3 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS 81 14 0.33 81 16 0.09 81 27 0.42 0.43 0.27 81 30 0.15 81 37 0.34 81 40 0.49 0.43 81 42 0.41 81 45 0.18 81 46 0.36 0.26 81 47 0.39 81 48 0.56 81 54 0.51 81 55 0.38 0.35 0.63 0.29 81 56 0.21 0.42 0.40 0.45 0.42 0.34 81 57 0.45 81 59 1.64 81 93 0.20 81 103 0.17 0.17 81 119 1.57 81 120 0.44 81 130 0.12 0.13 81 131 0.08 0.09 0.08 0.11 82 1

6.07 82 4

1.96 82 5

3.84 82 6

2.19 0.57 0.23 82 9

0.78 0.32 82 32 0.38 82 33 0.37 82 40 0.35 82 41 0.18 0.26 0.18 82 42 0.47 82 43 0.21 0.39 0.12 82 44 0.33 0.29 0.18 82 46 0.80 82 83 0.13 0.09 0.09 82 123 0.11 0.11 0.10 0.10 0.11 0.11 0.09 0.09 0.14 0.14 0.11 DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG 59 2

97 2

36 2

37 2

141 P 3 125 2 139 P 3 138 P 3 123 P 3 135 P 3 167 P 3 164 P 3 151 P 3 159 P 3 141 P 3 109 P 3 141 P 3 117 P 3 147 P 3 137 P 3 153 P 3 23 P 3 156 P 3 81 P 3 105 P 3 161 P 3 151 P 3 55 P 3 85 2

77 2

77 2

17 2

90 P 3 93 2

44 2

68 2

71 2

103 2 68 2

15 P 1 22 P 1 20 P 1 18 P 1 89 P 3 97 2

111 P 3 154 P 3 72 P 3 115 P 3 150 P 3 154 P 3 156 P 3 53 P 3 61 P 3 161 P 3 157 P 3 149 P 3 120 P 3 150 P 3 88 P 3 98 P 3 69 2

105 2 105 2 68 2

68 2

56 2

56 2

70 2

70 2

73 2

73 2

69 2

69 2

101 2 VOL VOL SAI TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL SAI TWD TEA TWD VOL VOL VOL VOL VOL VOL DRS DRS DRS DRS TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL SAI TWD SAI TWD SAI TWD SAI TWD SAI TWD SAI TWD SAI 013

-0.67 UTS

+0.04 UTS

-0.07 99 UTS

-0.07 5

015

-0.85 015

+0.58 8

014

+0.73 11 010

+0.47 8

010

-0.71 9

009

-0.67 4

010

+0.58 8

009

-0.75 6

009

+0.40 9

009

-0.75 12 009

-0.74 11 008

-0.60 8

009

-0.70 8

008

-0.64 13 008

+0.61 7

007

-0.61 5

009

-0.72 8

008

-0.73 9

008

+0.72 9

007

+0.56 9

007

-0.62 8

005

+0.66 10 005

+0.58 16 005

+0.63 014

+1.14 UTS

-19.65 17 UTS

-19.65 UTE

-0.19 7

014

+0.73 013

+1.15 013

+0.87 015

+14.52 015

+10.63 UTS

-17.00 UTS

-17.18 UTE

-0.76 UTE

-0.86 UTE

-0.69 UTE

-0.82 10 010

+0.03 011

+1.17 13 011

+0.63 5

013

+0.69 8

010

+0.67 8

010

+0.40 8

010

+0.33 4

010

+0.60 6

008

+0.71 4

008

-0.71 10 009

-0.64 5

010

+0.77 9

009

-0.63 3

007

-0.72 7

010

+0.68 7

008

-0.65 4

008

+0.65 16 009

-0.67 LTS

+15.16 011

+7.32 17 011

+7.32 015

-6.03 48 015

-6.03 015

-5.04 73 015

-5.04 015

-3.62 42 015

-3.62 015

-2.98 32 015

-2.98 015

-6.58 45 015

-6.58 015

-13.90 013 UTS UTS UTS 015 015 014 010 010 009 010 009 009 009 009 008 009 008 008 007 009 008 008 007 007 005 005 005 014 UTS UTS UTE 014 013 013 015 015 UTS UTS UTE UTE UTE UTE 010 011 011 013 010 010 010 010 008 008 009 010 009 007 010 008 008 009 LTS 011 011 015 015 015 015 015 015 015 015 015 015 015 013 UTS UTS UTS 015 015 014 010 010 009 010 009 009 009 009 008 009 008 008 007 009 008 008 007 007 005 005 005 014 UTS UTS UTE 014 013 013 015 015 UTS UTS UTE UTE UTE UTE 010 011 011 013 010 010 010 010 008 008 009 010 009 007 010 008 008 009 LTS 011 011 015 015 015 015 015 015 015 015 015 015 015 WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR 4041 4041 903 903 903 4041 4047 4047 4047 4047 4047 4047 4047 4047 4047 4047 4047 4047 4047 4047 4047 4047 4047 4047 4047 4047 4047 4003 4023 4024 4024 2070 4024 4028 4028 4028 4028 4028 4028 1007 1006 1007 1007 4063 4063 4063 4063 4047 4047 4047 4047 4047 4047 4047 4047 4047 4047 4047 4047 4047 4047 4023 4023 4023 4024 4024 4024 4024 4024 4024 4024 4024 4024 4024 4024 INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET PROBE 460SI 460SI 4 6OLW 4 6OLW 460LW 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 400PS 400PS 400PS 400PS 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI SLV SLV SLV SLV WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:29:50 Component: S/G A Page 16 of 31 ATTACHMENT #3 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS 0.11 82 125 0.65 83 1

6.71 83 2

4.01 83 8

1.71 83 15 0.82 0.82 83 26 0.56 83 27 0.25 83 28 0.46 83 31 0.33 83 32 0.39 83 34 0.36 83 37 0.36 83 43 0.37 0.45 83 97 2.67 83 98 0.17 0.17 0.09 0.09 83 104 0.21 83 129 2.03 83 132 0.10 0.16 0.08 0.08 0.11 0.19 84 1

4.83 84 2

2.77

0. 64 84 3

2.10 0.38 84 4

5.10 84 16 0.29 0.29 0.89 0.89 84 17 0.06 0.06 0.08 0.08 0.06 0.06 0.08 0.08 0.05 0.05 84 19 0.36 84 26 0.20 84 28 0.38 84 30 0.42 84 55 0.56 84 64 0.99 84 118 0.46 0.14 0.54 0.11 84 127 1.59 1.94 85 9

0.37 85 14 0.39 85 25 0.22 85 26 0.42 0.35 85 27 0.71 85 29 0.67 85 34 0.37 85 36 0.32 85 42 0.70 0.39 0.39 85 44 0.56 85 84 0.12 DEG 101 113 16 27 102 33 33 120 69 125 139 63 128 129 148 54 183 92 92 76 76 39 17 70 81 146 101 90 147 23 8

97 26 115 26 97 94 31 31 79 79 83 83 94 94 87 87 84 84 115 100 135 90 110 24 93 68 93 53 18 193 75 131 110 139 92 125 123 156 165 137 155 98 113 84 CHN 2

P 3 P 1 P I P 3 2

2 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 1

2 2

2 2

2 2

2 2

2 2

2 2

P 1 P 1 P 3 P 1 2

P1 2

2 2

2 2

2 2

2 2

2 2

2 2

2 P 3 P 3 P 3 P 3 P3 2

2 2

2 2

2 1

P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 2

IND TWD TWD DRS DRS TWD SAI TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD DNT SAI TWD SAI TWD VOL TEA VOL VOL VOL VOL VOL VOL DRS DRS TWD DRS VOL DRS VOL VOL SAI TWD SAI TWD SAI TWD SAI TWD SAI TWD SAI TWD TWD TWD TWD TWD TWD TEA VOL VOL TWD TWD TEA DNT TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD SAI

%TW LOCATION 1

015 10 014 UTE UTE 26 010 UTE 100 UTE 13 010 6

010 11 010 7

009 9

010 8

010 8

010 8

009 10 008 LTS 008 H

28 008 H

008 H

44 008 H

010 H

UTE 015 H

015 H

015 H

015 H

015 H

015 H

UTE UTE 11 010 UTE 010 H

UTE UTE UTE UTE 91 UTE 014 27 014 014 11 014 013 0

013 013 0

013 013 24 013 8

011 4

5 010

+

9 010 4

9 015 4

12 005 4

UTE 014 4

014

+

0 014

+

79 014

+

UTE UTS 9

009 10 010 6

010

+

10 010

+

9 010 16 010 14 010 8

009 7

009 15 009

+

9 009 9

008 12 008 011

-13.90

+0.73

-0.82

-0.81

+0.07

-1.17

-1.17

+0.34

+0.47

+0.57 F0.62

-0.67 0.56

+0.36

-0.75

-0.69

+0.14

+17.94

+17.94

-18.99

-18.99

-5.41

-0.15

-13.45

-18.45

-18.98

-19.23

-27.32

-27.55

-0.92

-1.02

-0.28

-0.83

-0.59

-0.76

-3.03

-2.94

-1.22

-1.22

-8.86

-8.86

-9.88

-9.88

-1.74 1.74

-3.81 3.81

  • 2.58
  • 2.58 0.66 0.58 0.52 0.66 0.64 0.18 0.85 1.08 0.85 1.08 0.20 5.78 0.60 0.45 0.66 0.66 0.66 0.70 0.73 0.68 0.85 0.69 0.71 0.73 0.65 14.92 EXT 015 014 UTE UTE 010 UTE UTE 010 010 010 009 010 010 010 009 008 LTS 008 008 008 008 010 UTE 015 015 015 015 015 015 UTE UTE 010 UTE 010 UTE UTE UTE UTE UTE 014 014 014 014 013 013 013 013 013 013 011 010 010 015 005 UTE 014 014 014 014 UTE UTS 009 010 010 010 010 010 010 009 009 009 009 008 008 011 EXT 015 014 UTE UTE 010 UTE UTE 010 010 010 009 010 010 010 009 008 LTS 008 008 008 008 010 UTE 015 015 015 015 015 015 UTE UTE 010 UTE 010 UTE UTE UTE UTE UTE 014 014 014 014 013 013 013 013 013 013 011 010 010 015 005 UTE 014 014 014 014 UTE UTS 009 010 010 010 010 010 010 009 009 009 009 008 008 011 UTIL 1 UTIL 2 CAL #

4024 WAR 4024 SLV 1007 SLV 1007 WAR 4063 TR 2083 2083 WAR 4041 WAR 4041 WAR 4041 WAR 4047 WAR 4047 WAR 4047 WAR 4047 WAR 4047 WAR 4047 4023 4023 4023 4023 4023 4024 2070 4028 4028 4028 4028 4028 4028 SLV 1009 SLV 1009 WAR 4063 SLV 1009 4063 SLV 1006 2096 2097 TR 2083 2083 4041 4041 4041 4041 4041 4041 4041 4041 4041 4041 WAR 4041 WAR 4041 WAR 4041 WAR 4047 WAR 4047 2004 4024 4024 4024 4024 2069 4024 WAR 4041 WAR 4041 WAR 4041 WAR 4041 WAR 4041 WAR 4041 WAR 4047 WAR 4047 WAR 4047 WAR 4047 WAR 4047 WAR 4047 WAR 4047 4023 LEG OUTLET OUTLET INLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET OUTLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET PROBE 460SI 460SI 400PS 400PS 460SI 460HR 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460SI 400PS 400PS 460SI 400PS 460SI 400PS 4 60HR 460HR 4 60HR 4 60HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460SI 4 60HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:29:50 Component: S/G A Page 17 of 31 ATTACHMENT #3 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS 0.12 85 91 0.26 85 118 0.22 85 129 9.43 85 130 0.85 86 1

3.74 4.82 0.48 86 2

4.87 86 11 0.51 86 14 0.39 86 28 0.52 86 30 0.41 86 32 0.52 86 34 0.64 86 55 0.52 86 64 1.00 86 67 0.99 86 96 1.74 86 129 8.40 86 131 0.06 0.21 87 1

4.42 87 9

0.27 87 13 0.16 87 36 0.93 87 50 0.29 87 122 0.26 87 129 8.52 87 130 0.82 88 3

0.68 0.60 88 25 1.18 88 80 0.16 88 122 0.23 89 2

13.37 0.45 89 17 0.35 89 37 0.11 0.11 0.05 0.05 89 82 0.16 89 118 2.60 90 6

0.47 90 13 0.14 0.14 90 43 0.45 90 115 0.33 91 2

0.69 91 7

0.31 91 17 0.32 0.31 91 38 1.21 91 42 0.38 91 80 0.15 0.15 91 81 3.31 91 82 0.11 0.11 91 108 8.11 91 117 0.93 91 118 0.15 91 119 0.69 91 120 0.67 91 125 0.15 0.23 0.34 92 9

0.97 92 83 0.12 0.12 92 89 0.25 0.25 0.15 0.15 DEG CHN IND %T; 84 2

TWD 36 53 2

VOL 72 2

VOL 184 1 DNT 49 P 3 TWD 12 16 P 2 DRS 169 1 DNT 140 P 3 TWD 8 18 P 1 DRS 123 P 3 TWD 12 130 P 3 TWD 8 120 P 3 TWD 12 96 P 3 TWD 9 154 P 3 TWD 11 148 P 3 TWD 13 116 2 VOL 18 2

TEA 43 P 3 TWD 10 325 1 DNT 181 1 DNT 105 2 VOL 70 P 3 TWD 3 16 P 1 DRS 57 2

VOL 86 2

VOL 17 2

TEA 154 2 VOL 57 2

VOL 179 1 DNT 40 1

VOL 116 P 3 TWD 11 114 P 3 TWD 10 20 2

TEA 45 2

VOL 119 2 VOL 171 1 DNT 131 P 3 TWD 8 134 P 3 TWD 7 85 2

SAI 85 2

TWD 15 90 2

SAI 90 2

TWD 1 39 2

VOL 188 1 DNT 85 P 3 TWD 11 79 2

SAI 79 2

TWD 27 102 2 VOL 47 2

VOL 120 P 3 TWD 12 122 P 3 TWD 8 87 2

VOL 84 2

TWD 27 21 2

TEA 70 2

VOL 66 2

SAI 66 2

TWD 55 179 1 DNT 95 2

SAI 95 2

TWD 26 185 1 DNT 13 2

TEA 85 2

VOL 75 P 3 TWD 10 0

P 3TWD 6 81 2

VOL 95 2

VOL 87 2

VOL 17 2

TEA 84 2

SAI 84 2

TWD 36 78 2

SAI 78 2

TWD 42 70 2

SAI 70 2

TWD 51 q LOCATION 011

-14.92 012

+18.84 003

-6.46 008

-0.22 009

+0.01 UTE

-0.87 LTS

-14.02 014

+0.67 UTE

-0.97 010

-0.60 011

-0.68 009

-0.66 009

-0.61 009

-0.80 009

-0.69 005

-0.80 UTE

-0.15 004

-0.78 LTS

+0.05 008

-0.18 013

+1.42 013

-0.70 UTE

-0.92 010

-0.66 010

-0.42 UTE

-0.20 009

-0.82 002

+0.67 008

+0.26 012

+15.35 011

+0.70 012

-0.78 UTE

-0.24 014

+8.95 015

+0.64 010

-0.18 011

+0.48 009

-0.75 015

-16.63 015

-16.63 015

-15.46 015

-15.46 010

+15.62 LTS

+18.67 009

-0.63 014

-7.04 014

-7.04 015

+0.79 014

+1.06 011

+0.54 010

+0.58 015

+0.88 015

+0.88 UTE

-0.20 015

+0.76 012

-16.49 012

-16.49 LTE

+5.66 012

+1.77 012

+1.77 LTS

-13.71 UTE

-0.23 014

+1.10 015

-0.70 008

-0.71 009

+0.56 014

+2.60 014

+2.83 UTE

-0.14 011

+12.95 011

+12.95 009

+2.89 009

+2.89 009

+9.94 009

+9.94 EXT 011 012 003 008 009 UTE LTS 014 UTE 010 011 009 009 009 009 005 UTE 004 LTS 008 013 013 UTE 010 010 UTE 009 002 008 012 011 012 UTE 014 015 010 011 009 015 015 015 015 010 LTS 009 014 014 015 014 011 010 015 015 UTE 015 012 012 LTE 012 012 LTS UTE 014 015 008 009 014 014 UTE 011 011 009 009 009 009 EXT UTIL 1 UTIL 2 011 012 003 008 009 WAR UTE SLV LTS 014 WAR UTE SLV 010 WAR 011 WAR 009 WAR 009 WAR 009 WAR 009 WAR 005 UTE 004 WAR LTS 008 013 013 WAR UTE SLV 010 010 UTE 009 002 008 012 011 WAR 012 WAR UTE 014 015 010 011 WAR 009 WAR 015 015 015 015 010 LTS 009 WAR 014 014 015 014 011 WAR 010 WAR 015 015 UTE 015 012 012 LTS 012 012 LTS UTE 014 015 WAR 008 WAR 009 014 014 UTE 011 011 009 009 009 009 CAL

  • 4023 4023 4024 4028 4028 1009 4063 4063 1009 4041 4041 4047 4047 4047 4047 4047 2004 4003 4023 4024 4028 4028 1009 4041 4041 2084 4047 4024 4024 4028 4063 4063 2084 4023 4024 4063 4063 4041 4047 4047 4047 4047 4023 4024 4041 4041 4041 4047 4024 4063 4041 4041 4041 2082 4047 4023 4023 4023 4023 4023 4024 2066 4024 4024 4024 4024 4024 4024 2082 4023 4023 4023 4023 4023 4023 LEG OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET OUTLET OUTLET INLET INLET INLET INLET OUTLET OUTLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET PROBE 460SI 460SI 460SI 460SI 460SI 400PS 460SI 460SI 400PS 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460SI 400PS 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460SI

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:29:50 Component: S/G A Page 18 of 31 ATTACHMENT #3 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 0.09 0.09 0.12 0.12 0.18 0.18 0.16 0.16

0. 12 0.12 0.18 0.18 0.16 0.16 0.20 0.20 0.16 0.16 0.13 0.13 0.12 0.12 0.07 0.07 0.11 0.11 0.18 0.18 0.06 0.06
0. 10 0.10 0.08 0.08 0.08 0.08 0.07 0.07 92 96 0.35 0.35 0.33 0.33 0.25 0.25 92 109 0.21 92 112 0.38 93 11 0.08 93 12 0.30 93 38 1.28 93 87 2.39 93 88 0.11 0.11 0.12 0.12 0.11 0.11 0.17 0.17 0.10 0.10 0.09 0.09 0.07 0.07 93 113 0.32 0.32 93 123 0.68 0.47 87 2

87 2

75 2

75 2

81 2

81 2

87 2

87 2

93 2

93 2

85 2

85 2

80 2

80 2

74 2

74 2

64 2

64 2

89 2

89 2

80 2

80 2

101 2 101 2 76 2

76 2

64 2

64 2

85 2

85 2

86 2

86 2

87 2

87 2

67 2

67 2

77 2

77 2

72 2

72 2

70 2

70 2

68 2

68 2

47 2

77 2

60 2

56 2

19 2

199 1 86 2

86 2

89 2

89 2

87 2

87 2

88 2

88 2

87 2

87 2

82 2

82 2

95 2

95 2

65 2

65 2

71 2

84 2

SAI TWD 33 SAI TWD 45 SAI TWD 39 SAI TWD 33 SAI TWD 27 SAI TWD 35 SAI TWD 40 MAI TWD 46 SAI TWD 58 SAI TWD 31 SAI TWD 40 SAI TWD 20 SAI TWD 44 SAI TWD 58 SAI TWD 35 SAI TWD 34 SAI TWD 33 SAI TWD 54 SAI TWD 43 SAI TWD 49 SAI TWD 51 SAI TWD 53 VOL VOL VOL VOL TEA DNT SAI TWD 34 SAI TWD 31 SAI TWD 33 SAI TWD 32 SAI TWD 33 SAI TWD 38 SAI TWD 26 SAI TWD 87 VOL VOL 009 009 010 010 010 010 010 010 010 010 010 010 010 010 010 010 010 010 010 010 010 010 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 010 010 010 010 010 010 013 009 002 003 UTE LTS 012 012 012 012 012 012 012 012 012 012 012 012 012 012 010 010 009 009 011 011 012 014 UTE UTE UTE

+8.56

+8.56

-7.45

-7.45

-2.15

-2. 15

+2. 18

+2. 18

+5. 14

+5. 14

+5. 99

+5. 99

+10.51

+10.51

+16. 95

+16.95

+22.30

+22.30

+25.95

+25.95

+28.08

+28.08

+3.57

+3.57

-2.54

-2.54

-5.33

-5.33

-15. 64

-15.64

-17.62

-17.62

-19.46

-19.46

-18.81

-18.81

-18.42

-18.42

-12.62

-12.62

-17.12

-17.12

-18.47

-18.47

-6.29

-6.94

-10.53

+8.48

-0.18

+0.07

-11.48

-11.48

-12.72

-12.72

-14.95

-14.95

-15.92

-15.92

-17.16

-17.16

-18.15

-18.15

-19.44

-19.44

+6.96

+6.96

+0.59

+1.14

-0.74

+0. 64

-0.67

+0. 68

-2.98

-0.17

-0.17 009 009 009 009 010 011 010 011 010 011 010 011 010 011 010 011 010 011 010 011 010 011 010 011 010 011 010 011 010 011 010 011 010 011 010 011 010 011 010 011 010 011 010 011 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 010 010 010 010 010 010 010 010 010 010 010 010 013 013 009 009 002 002 003 003 UTE UTE LTS LTS 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 010 010 010 010 009 009 009 009 011 011 011 011 012 012 014 014 UTE UTE UTE UTE UTE UTE 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4024 OUTLET 4024 OUTLET 4041 INLET 4041 INLET 2082 INLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4024 OUTLET 4024 OUTLET 4024 OUTLET 4024 OUTLET 4024 OUTLET 4063 OUTLET 4063 OUTLET 4041 INLET 2096 INLET 2002 INLET 2002 INLET 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 4 60HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460HR 4 60HR 94 2

94 26 94 55 94 63 94 69 0.72

0. 68 0.14 0.16 0.14
0. 65
0. 61 76 P 3 TWD 11 123 P 3 TWD 12 103 2 VOL 79 2

VOL 98 2

VOL 27 2

TEA 20 2

TEA WAR WAR

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:29:50 Component: SIG A Page 19 of 31 ATTACHMENT #3 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

=

==

==

=

=

=

=

====

==

==

==

=

==

=

94 90 3.81 0.16 0.16 0.23 0.23 0.16 0.16 0.15 0.15 0.13 0.13 0.33 0.33 0.33 0.33 0.28 0.28 94 95 7.06 4.57 94 124 0.25 0.18 95 61 4.82 95 64 1.60 95 69 0.55 95 112 0.18 95 117 0.33 96 4

0.21 96 60 0.98 96 63 0.16 96 89 0.27 0.27 0.23 0.23 0.30 0.30 0.20 0.20 0.23 0.23 0.21 0.21 0.05 0.05 0.05 0.05 0.06 0.06 0.21 0.10 0.10

0. 10
0. 10 0.13 0.13 0.21 96 92 0.09
0. 09 0.11 0.11
0. 07
0. 07 96 115 0.11 97 2

0.24 97 14 1.30 97 31 0.10 97 78 1.84 97 87 0.84 97 88 13.06 98 2

0.20 0.18 98 3

0.26 98 52 1.33 98 91 0.31 98 122 0.16 99 3

0.31 177 1 88 2

88 2

88 2

88 2

92 2

92 2

88 2

88 2

90 2

90 2

65 2

65 2

61 2

61 2

61 2

61 2

167 1 168 1 53 2

66 2

4 1

24 2

62 2

65 2

72 2

142 2 22 2

66 2

82 2

82 2

80 2

80 2

79 2

79 2

79 2

79 2

77 2

77 2

78 2

78 2

83 2

83 2

76 2

76 2

71 2

71 2

80 2

74 2

74 2

71 2

71 2

69 2

69 2

80 2

87 2

87 2

78 2

78 2

63 2

63 2

109 2 97 2

92 1

47 2

18 2

8 2

187 1 72 2

73 2

125 2 12 2

60 2

32 2

DNT SAI TWD 32 SAI TWD 32 SAI TWD 28 SAI TWD 32 SAI TWD 30 SAI TWD 56 SAI TWD 61 SAI TWD 61 DNT DNT VOL VOL DNT TEA VOL VOL VOL VOL TEA VOL SAI TWD 38 SAI TWD 40 SAI TWD 41 SAI TWD 41 SAI TWD 43 MAI TWD 42 SAI TWD 37 SAI TWD 44 SAI TWD 50 SAI SAI TWD 46 SAI TWD 50 SAI TWD 52 TWD 40 SAI TWD 33 SAI TWD 42 SAI TWD 59 VOL VOL VOL VOL TEA VOL DNT SVI TWD 24 VOL TEA VOL VOL LTS 010 010 010 010 010 010 010 010 010 010 011 011 011 011 011 011 LTS LTS 001 008 014 UTE 014 012 014 004 UTE 014 009 009 009 009 009 009 009 009 009 009 009 009 009 009 009 009 009 009 009 009 009 009 009 009 009 009 011 011 011 011 011 011 006 006 014 014 UTE 009 LTS 015 015 010 UTE 014 014 010

-14.12

-2.18

-2.18

-3.99

-3. 99

-6.56

-6.56

-7.85

-7.85

-10.13

-10.13

-8.94

-8.94

-10.18

-10.18

-16.73

-16.73

-11. 02

-11.40

+10. 50

+18.79

+30.51

-0.15

+24.21

-5.97

+10. 55

-0.80

-0.17

+10. 30

-8.62

-8.62

-9.84

-9.84

-11.93

-11.93

-13.10

-13.10

-14.92

-14.92

-15.59

-15.59

-16.54

-16.54

-17.11

-17.11

-23.39

-23.39

-23. 68

-23.90

-23.90

-25.42

-25.42

-26.66

-26.66

-23.68

+9.25

+9.25

+10.45

+10.45

+11.21

+11.21

-9.77

+1. 00

-17.12

+10. 25

-0.20

-19.22

-7.11

+0. 10

+0. 10

+0.55

-0.18

-10.24

+1.21

+0.63 LTS LTS 010 010 010 010 010 010 010 010 010 010 010 010 010 010 010 010 010 010 010 010 011 011 011 011 011 011 011 011 011 011 011 011 LTS LTS LTS LTS 001 001 008 008 015 014 UTE UTE 014 015 012 012 014 014 004 004 UTE UTE 014 014 009 009 009 009 009 009 009 009 009 009 009 009 009 009 009 009 009 009 009 009 009 009 009 009 009 009 009 009 009 009 009 009 009 009 009 009 009 009 009 009 009 009 009 009 009 009 009 009 009 009 009 009 011 011 011 011 011 011 011 011 011 011 011 011 006 006 006 006 014 014 014 014 UTE UTE 009 009 LTS LTS 015 015 015 015 010 010 UTE UTE 014 014 014 014 010 010 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4024 OUTLET 4024 OUTLET 4001 INLET 2002 INLET 4004 OUTLET 4024 OUTLET 4024 OUTLET 4041 INLET 2083 INLET 4052 INLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4023 OUTLET 4024 OUTLET 4041 INLET 4041 INLET 4052 INLET 2011 INLET 4023 OUTLET 4023 OUTLET 904 INLET 904 INLET 4041 INLET 2082 INLET 4021 OUTLET 4021 OUTLET 4041 INLET 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 4 60HR 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 4 60SI 4 60SI 4 60SI 4 60SI 4 60SI 4 60SI 4 60SI 4 60SI 460SI 4 60HR 4 60SI 460SI 4 6OLW 4 60LW 460SI 4 60HR 460SI 460SI 460SI 100 P 3 TWD 8 WAR

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:29:50 Component: S/G A Page 20 of 31 ATTACHMENT #3 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS 0.35 99 11 0.11 99 12 2.97 99 13 0.53 0.53 99 14 0.28 99 53 0.25 99 56 0.10 99 60 0.10 0.10 0.08 0.08 0.08 0.08 99 86 3.19 99 87 3.19 100 7 0.13 100 34 1.03 100 50 0.10 100 65 0.18 100 84 4.44 101 6 0.18 101 16 0.18 102 28 0.93 102 105 0.09 102 109 0.11 0.11 102 122 0.37 102 123 1.81 103 3 0.96 103 51 0.13 103 53 0.11 1.40 103 81 4.83 103 1ll 0.39 103 123 0.12 0.12 0.15 0.15 103 124 1.08 104 11 1.18 104 14 0.07 104 30 2.69 104 34 0.78 104 36 0.68 104 50 1.88 104 61 0.15 0.15 0.12 0.12 104 79 3.05 104 82 3.49 104 112 0.31 104 120 0.61 104 122 0.37 105 6 1.48 105 17 1.14 105 55 0.71 2.00 105 78 3.55 105 79 6.25 105 105 0.16 105 108 4.30 106 51 2.86 106 88 1.20 107 46 0.09 107 48 0.12 107 56 2.29 107 61 0.17 0.19 0.19 0.18 0.18 107 68 2.15 107 69 3.24 DEG 94 55 19 27 27 65 52 70 72 72 84 84 76 76 175 189 40 21 69 45 181 61 65 27 98 43 57 106 21 116 64 64 191 181 134 84 84 74 74 171 17 65 22 22 16 184 82 82 72 72 181 22 0

0 29 15 24 15 175 177 177 52 175 178 16 62 67 174 68 96 96 109 109 176 144 CHN 2

2 2

2 2

2 2

2 2

2 2

2 2

2 1

1 2

2 2

2 1

2 2

2 2

2 2

2 2

P3 2

2 1

1 2

2 2

2 2

1 2

2 2

2 2

1 2

2 2

2 1

2 P3 P3 P3 2

2 2

1 1

1 2

1 1

2 2

2 1

2 2

2 2

2 1

1 IND VOL VOL TEA SAI TWD VOL VOL VOL SAI TWD SAI TWD SAI TWD DNT DNT VOL TEA VOL VOL DNT VOL VOL TEA VOL VOL VOL VOL TEA TWD VOL VOL DNT DNT VOL SAI TWD SAI TWD DNT TEA VOL TEA TEA TEA DNT SAI TWD SAI TWD DNT TEA TWD TWD TWD TEA TEA TEA DNT DNT DNT VOL DNT DNT TEA VOL VOL DNT VOL SAI TWD SAI TWD DNT DNT

%TW LOCATION EXT EXT 009

+12.29 009 009 001

-5.43 001 001 UTE

-0.14 UTE UTE UTE

-2.63 UTE UTS 76 UTE

-2.63 UTE UTS 014

+0.79 014 014 014

-0.15 014 014 011

-3.91 011 011 012

-12.41 012 012 53 012

-12.41 012 012 012

-19.18 012 012 45 012

-19.18 012 012 012

-20.26 012 012 50 012

-20.26 012 012 LTS

+0.08 LTS LTS LTS

+0.14 LTS LTS 010

+4.48 010 010 UTE

-0.15 UTE UTE 003

-5.39 003 003 008

-7.84 008 008 LTS

+0.13 LTS LTS 009

-16.40 009 009 010

-19.66 010 010 UTE

-0.17 UTE UTE 005

-12.11 005 005 LTS

+19.93 LTS LTS 012

+5.16 012 012 010

-0.68 010 010 UTE

-0.22 UTE UTE 21 010

+0.72 010 010 009

-15.03 009 009 LTS

+10.29 LTS LTS LTS

+0.17 LTS LTS LTS

-0.01 LTS LTS 013

+0.75 013 013 012

+19.10 012 012 29 012

+19.10 012 012 012

+17.16 012 012 45 012

+17.16 012 012 UTS

-0.08 UTS UTS UTE

-0.21 UTE UTE 015

-5.31 015 015 UTE

-0.20 UTE UTE UTE

-0.15 UTE UTE UTE

-0.20 UTE UTE LTS

+0.18 LTS LTS UTS

-16.11 UTS UTS 46 UTS

-16.11 UTS UTS UTS

-17.78 UTS UTS 53 UTS

-17.78 UTS UTS LTS

+0.15 LTS LTS UTE

-0.31 UTE UTE 6

015

+0.45 015 015 12 009

-0.69 009 009 8

010

-0.52 010 010 UTE

-0.08 UTE UTE UTE

-0.19 UTE UTE UTE

-0.24 UTE UTE LTS

+0.13 LTS LTS LTS

+0.02 LTS LTS LTE

+2.37 LTE LTS 015

+16.12 015 015 LTE

+6.27 LTE LTE LTS

+0.13 LTS LTS UTE

-0.21 UTE UTE 013

+3.60 013 013 007

+3.99 007 007 LTS

-0.30 LTS LTS 004

+6.42 004 004 014

+6.10 014 014 7

014

+6.10 014 014 014

+6.97 014 014 l

014

+6.97 014 014 LTS

+0.00 LTS LTS LTS

+0.09 LTS LTS UTIL 1 UTIL 2 TR WAR WAR WAR WAR CAL #

4041 4041 2076 2077 2077 4041 4049 4049 4052 4052 4052 4052 4052 4052 4021 4021 4041 2077 4049 4030 4021 4041 4041 2077 4021 4021 4021 4021 2066 4041 4049 4049 4049 4020 4043 4016 4016 4016 4016 4024 2072 4041 2075 2075 2075 4049 4052 4052 4052 4052 4016 2010 4016 4016 4016 2072 2071 2071 4049 4016 4016 4016 4016 4049 2009 4052 4052 4049 4016 4016 4016 4016 4016 4016 4016 LEG INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET INLET INLET INLET OUTLET OUTLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET OUTLET OUTLET OUTLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET PROBE 460SI 460SI 460HR 460HR 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 4 6OHR 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 4 6OHR 460SI 460HR 460HR 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460HR 460HR 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:29:51 Component: S/G A Page 21 of 31 ATTACHMENT #3 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMi ROW TUBE VOLTS 107 70 3.06 107 71 4.59 107 74 4.22 107 75 2.44 107 76 2.80 107 78 3.07 107 104 3.07 107 118 2.67 3.15 3.59 107 120 0.11 0.10 0.10 0.61 0.61 0.41 0.41 0.37 0.37 108 4 0.39 108 8 2.74 108 41 0.31 108 91 0.33 0.33 0.26 0.26 108 111 3.51 2.88 109 4 0.36 109 50 0.14 0.14 0.17 0.17 0. 0 9 0.09 0.10 0.10 0.12 0.12 0.12 0.12 0.11 0.11 0.15 0.15 0.14 0.14 0.16 0.16 0.08 0.08 109 75 1.85 109 78 0.10 109 88 0.29 109 110 0.04 0.08 0.05 0.12 109 112 0.04 0.10 110 55 0.14 110 58 0.13 0.13 110 62 6.83 110 72 2.50 110 105 0.18 0.18 110 107 2.03 110 117 7.41 9.82 111 58 0.11 0.11 111 85 0.15 111 111 0.33 112 2 5.10 DEG CHN IND %TW LOCATION 180 1 DNT LTS

+0.09 176 1 DNT LTS

+0.02 176 1 DNT LTS

+0.17 174 1 DNT LTS

+0.08 177 1 DNT LTS

+0.19 179 1 DNT LTE

+4.64 188 1 DNT LTE

+6.32 161 1 DNT LTE

+3.94 165 1 DNT LTE

+5.10 161 1 DNT LTE

+6.69 48 2

VOL 002

+10.85 98 2

SAI 010

+11.23 98 2

TWD 3 010

+11.23 83 2

SAI 015

-1.55 83 2

TWD 31 015

-1.55 62 2

SAI 015

-2.70 62 2

TWD 62 015

-2.70 80 2

SAI 015

-1.99 80 2

TWD 36 015

-1.99 138 P 3 TWD 10 009

-0.55 23 2

TEA UTE

-0.22 80 2

VOL 012

+8.71 73 2

SAI 009

+7.87 73 2

TWD 46 009

+7.87 71 2

SAI UTS

-21.98 71 2

TWD 49 UTS

-21.98 40 2

SVI 010

+0.83 54 2

TWD 72 010

+0.83 135 P 3 TWD 9 015

-0.66 91 2

SAI 011

-12.16 91 2

TWD 41 011

-12.16 84 2

SAI 011

-11.76 TO-9.58 84 2

TWD 45 011

-11.76 TO-9.58 84 2

SAI 011

-9.55 TO-9.21 84 2

TWD 45 oia

-9.55 TO-9.21 94 2

SAI 011

-9.16 TO-6.95 94 2

TWD 40 011

-9.16 TO-6.95 79 2

SAI 011

-5.28 79 2

TWD 48 011

-5.28 76 2

SAI 011

-4.51 76 2

TWD 50 011

-4.51 88 2

SAI 011

-4.32 88 2

TWD 43 011

-4.32 69 2

SAI 011

-4.17 69 2

TWD 55 011

-4.17 81 2

SAI 011

-3.24 81 2

TWD 47 011

-3.24 62 2

SAI 011

-2.94 62 2

TWD 61 011

-2.94 76 2

SAI 010

+14.71 76 2

TWD 50 010

+14.71 17 2

TEA UTE

-0.20 63 2

VOL 008

+12.68 65 2

VOL 002

+13.91 68 2

VOL 011

+3.50 62 2

VOL 010

+19.27 70 2

VOL 010

+22.63 52 2

VOL 010

+24.11 90 2

VOL 010

+1.24 82 2

VOL 012

+1.04 50 2

VOL 008

+4.27 70 2

SAI 015

+14.52 70 2

TWD 39 015

+14.52 5

1 DNT 007

+18.21 18 2

TEA UTE

-0.15 84 2

VOL 014

+1.06 83 2

TWD 0 014

+1.06 25 2

TEA UTE

-0.31 182 1 DNT 015

+0.40 182 1 DNT UTS

+0.01 129 2 SAI 015

+1.34 129 2 TWD 47 015

+1.34 142 2 VOL UTS

+14.57 74 2

VOL 012

+1.14 178 1 DNT LTS

-13.41 EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE LTS LTS LTS LTS LTS LTE LTE LTE LTE LTE 002 010 010 015 015 015 015 015 015 009 UTE 012 009 009 UTS UTS 010 010 015 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 010 010 UTE 008 002 011 010 010 010 010 012 008 015 015 007 UTE 014 014 UTE 015 UTS 015 015 UTS 012 LTS LTS LTS LTS LTS LTS LTS LTS LTE LTE LTE 002 010 010 015 015 015 015 015 015 009 UTE 012 009 009 UTS UTS 010 010 015 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 010 010 UTE 008 002 011 010 010 010 010 012 008 015 015 007 UTE 014 014 UTE 015 UTS 015 015 UTS 012 LTS WAR WAR 4016 4016 4016 4016 4016 4016 4016 4016 4016 4016 4016 4016 4016 4016 4016 4016 4016 4016 4016 4041 2071 4052 4016 4016 4016 4016 4016 4016 4041 4052 4052 4052 4052 4052 4052 4052 4052 4052 4052 4052 4052 4052 4052 4052 4052 4052 4052 4052 4052 4052 4052 2009 4016 4016 4043 4016 4016 4016 4016 4016 4040 4040 4040 4006 2029 4043 4043 2061 4014 4014 4040 4040 4043 4006 4033 OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI

Framatome ANP Inc.

12/05/01 14:29:51 Customer Name: Oconee Unit 3 Component: S/G A Page 22 of 31 ATTACHMENT #3 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 112 9 1.79 19 2

TEA UTE

-0.22 UTE UTE 2059 INLET 460HR 112 16 0.15 67 2

VOL 013

-14.42 013 013 4040 OUTLET 460SI 112 18 0.10 69 2

VOL 011

+8.99 011 011 4040 OUTLET 460SI 112 25 0.28 165 2 VOL 015

+0.28 015 015 4040 OUTLET 460SI 112 60 0.87 4

2 TEA UTE

-0.15 UTE UTE 2029 INLET 460HR 112 62 2.29 32 2

TEA UTE

-0.17 UTE UTE 2029 INLET 460HR 112 112 0.08 76 2

VOL 012

+1.20 012 012 4007 OUTLET 460SI 112 116 0.13 94 2

VOL 014

-1.00 014 014 4014 OUTLET 460SI 113 2 4.68 189 1 DNT LTE

+3.36 LTE LTS 4033 OUTLET 460SI 2.38 150 1 DNT LTE

+5.45 LTE LTS 4033 OUTLET 460SI 0.09 119 2 TWD 17 013

-21.13 013 013 4033 OUTLET 460SI 0.10 131 2 SAI 013

-21.13 013 013 4033 OUTLET 460SI 0.13 32 2

SAI 013

-12.38 013 013 4033 OUTLET 460SI 0.11 105 2 TWD 26 013

-12.38 013 013 4033 OUTLET 460SI 0.09 110 2 SAI 013

-11.81 013 013 4033 OUTLET 460SI 0.09 110 2 TWD 23 013

-11.81 013 013 4033 OUTLET 460SI 113 7 1.14 27 2

SAI UTE

-1.19 UTE UTE TR 2060 INLET 460HR 1.14 27 2

TWD 87 UTE

-1.19 UTE UTE 2060 INLET 460HR 113 23 0.93 35 P 1 PVN UTE

-0.61 UTE UTE 2056 INLET 460HR 113 49 2.39 21 2

TEA UTE

-0.23 UTE UTE 2056 INLET 460HR 113 95 0.06 67 2

VOL 009

+2.02 009 009 4007 OUTLET 460SI 113 103 0.30 0

P 3 TWD 5 014

+0.71 014 014 WAR 4007 OUTLET 460SI 113 112 0.12 88 2

VOL 012

+1.24 012 012 4007 OUTLET 460SI 114 1 7.50 176 1 DNT LTS

-12.86 LTS LTS 4033 OUTLET 460SI 114 6 2.48 22 2

TEA UTE

-0.20 UTE UTE 2055 INLET 460HR 0.08 111 2 SAI 015

-3.59 015 015 4033 OUTLET 460SI 0.09 114 2 TWD 20 015

-3.59 015 015 4033 OUTLET 460SI 0.08 101 2 SAI 015

-2.58 015 015 4033 OUTLET 460SI 0.08 101 2 TWD 29 015

-2.58 015 015 4033 OUTLET 460SI 114 21 0.13 75 2

VOL 011

-5.37 011 011 4039 OUTLET 460SI 114 47 0.30 32 2

VOL 004

-0.11 004 004 4039 OUTLET 460SI 114 49 0.96 17 2

TEA UTE

-0.21 UTE UTE 2056 INLET 460HR 114 51 2.29 9

1 DNT 001

+6.58 001 001 4039 OUTLET 460SI 114 52 0.42 58 P 3 TWD 8 014

+0.69 014 014 WAR 4039 OUTLET 460SI 0.18 137 2 VOL 014

+0.35 014 014 4039 OUTLET 460SI 114 62 0.25 65 2

SAI UTS

-6.25 UTS UTS 4012 OUTLET 460SI 0.27 65 2

TWD 52 UTS

-6.25 UTS UTS 4012 OUTLET 460SI 114 102 4.22 186 1 DNT LTE

+4.79 LTE LTE 4012 OUTLET 460SI 114 103 0.31 63 2

VOL 014

+0.98 014 014 4012 OUTLET 460SI 0.30 63 2

TWD 57 014

+0.98 014 014 4012 OUTLET 460SI 114 107 1.51 22 2

TEA UTE

-0.17 UTE UTE 2062 INLET 460HR 114 110 0.34 1

2 VOL 009

-0.62 009 009 4007 OUTLET 460SI 114 114 0.50 91 P 3 TWD 7 010

+0.67 010 010 WAR 4043 OUTLET 460SI 0.09 94 2

VOL 014

+0.78 014 014 4007 OUTLET 460SI 115 7 2.62 23 2

TEA UTE

-0.16 UTE UTE 2055 INLET 460HR 115 8 1.06 21 2

TEA UTE

-0.15 UTE UTE 2056 INLET 460HR 115 27 0.78 20 2

TEA UTE

-0.21 UTE UTE 2055 INLET 460HR 115 46 11.97 180 1 DNT LTE

+4.61 LTE LTS 4039 OUTLET 460SI 115 56 1.26 177 1 DNT LTS

+0.15 LTS LTS 4036 OUTLET 460SI 115 61 0.24 33 P 3 TWD 6 004

-0.65 004 004 WAR 4012 OUTLET 460SI 115 102 0.31 55 2

VOL 002

+10.32 002 002 4012 OUTLET 460SI 115 114 6.01 6

1 DNT LTS

+0.69 LTS LTS 4012 OUTLET 460SI 116 2 0.64 18 2

SAI UTE

-1.20 UTE UTE TR 2056 INLET 460HR 0.64 18 2

TWD 52 UTE

-1.20 UTE UTE 2056 INLET 460HR 116 21 0.19 69 2

VOL 014

+0.46 014 014 4036 OUTLET 460SI 116 26 1.14 20 2

TEA UTE

-0.17 UTE UTE 2055 INLET 460HR 116 30 0.67 21 2

TEA UTE

-0.20 UTE UTE 2055 INLET 460HR 116 77 0.14 59 2

VOL 003

+21.23 003 003 4012 OUTLET 460SI 116 98 0.25 56 2

VOL 008

-5.89 008 008 4012 OUTLET 460SI 116 104 0.26 65 2

SAI 012

+6.29 012 012 4012 OUTLET 460SI 0.26 65 2

TWD 52 012

+6.29 012 012 4012 OUTLET 460SI 116 107 0.68 0

P 3 TWD 14 009

-0.51 009 009 WAR 4012 OUTLET 460SI 117 10 0.12 61 2

VOL 010

+4.34 010 010 4036 OUTLET 460SI 117 20 0.33 70 2

VOL 015

+0.84 015 015 4036 OUTLET 460SI 117 49 0.60 92 P 3 TWD 8 015

+0.77 015 015 WAR 4036 OUTLET 460SI 117 89 0.25 0

P 3 TWD 6 015

+0.75 015 015 WAR 4012 OUTLET 460SI 0.54 22 2

SAI UTE

-3.15 UTE UTS TR 2030 INLET 460HR 0.54 22 2

TWD 76 UTE

-3.15 UTE UTS 2030 INLET 460HR 117 90 0.44 111 2 VOL 015

+0.81 015 015 4012 OUTLET 460SI 2.46 23 2

TEA UTE

-0.25 UTE UTE 2029 INLET 460HR 117 102 0.73 23 2

SAI UTE

-1.05 UTE UTE TR 2062 INLET 460HR 0.73 23 2

TWD 77 UTE

-1.05 UTE UTE 2062 INLET 460HR 117 107 0.11 113 2 VOL 010

+20.44 010 010 4012 OUTLET 460SI 118 3 2.25 22 2

TEA UTE

-0.16 UTE UTE 2056 INLET 460HR 118 4 1.98 16 2

TEA UTE

-0.19 UTE UTE 2055 INLET 460HR

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:29:51 Component: S/G A Page 23 of 31 ATTACHMENT #3 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW 118 118 118 118 118 118 118 119 119 119 119 119 120 120 120 120 120 121 121 121 121 121 121 121 121 121 122 122 122 122 122 122 123 123 123 123 123 123 123 123 123 123 124 124 124 124 124 124 124 124 124 124 124 124 125 125 125 125 125 TUBE VOLTS 6

1.19 20 0.16 0.16 21 0.09 90 0.26 100 0.17 1.18 101 0.22 102 1.47 22 2.15 55 0.69 84 0.10 88 1.07 91 2.04 5

1.63 44 2.81 55 0.13 58 0.24 0.24 69 0.17 4

1.83 5

0.30 16 1.00 21 1.33 30 1.21 41 0.85 42 0.13 48 1.11 50 0.11 4

2.90 0.39 0.40 0.09 0.09 8

0.15 12 0.97 0.97 39 0.80 85 0.18 92 0.24 11 1.71 20 1.25 21 1.42 23 1.28 27 0.80 29 0.24 87 2.60 88 1.31 102 0.11 0.31 0.29 104 7.45 0.29 1

0.72 0.72 4

0.86 9

0.65 13 1.34 15 1.52 16 1.59 41 2.26 45 0.12 0.12 0.14 0.14 0.10 58 0.22 85 0.47 93 1.45 101 7.65 4

1.10 36 0.34 41 1.69 50 0.10 99 5.63 DEG 22 67 67 53 62 79 17 0

19 25 42 70 14 21 23 26 65 54 54 66 19 137 18 22 14 75 77 15 71 21 77 75 83 83 49 23 23 14 51 68 27 24 34 14 17 63 30 21 61 57 65 192 103 33 33 88 14 15 17 18 23 58 58 61 61 46 55 147 20 185 68 66 20 42 187 CHN 2

2 2

2 2

2 2

P 3 2

2 P3 2

2 2

2 2

2 2

2 2

2 2

2 2

2 1

2 2

2 2

2 2

2 2

2 2

2 2

P 3 2

2 2

2 2

2 2

2 2

2 2

2 1

2 2

2 P 3 2

2 2

2 2

2 2

2 2

2 2

2 2

1 P23 2

2 2

1 IND %TW LOCATION TEA UTE VOL UTS TWD 47 UTS VOL 010 VOL 012 VOL 010 TEA UTE TWD 5 009 TEA UTE TEA UTE TWD 14 003 VOL 001 TEA UTE TEA UTE TEA UTE TEA UTE VOL 011 SAI 012 TWD 76 012 VOL 003 TEA UTE VOL 010 H

TEA UTE TEA UTE TEA UTE VOL UTS H

VOL 008 TEA UTE VOL 002

+

TEA UTE SAI 015 TWD 50 015 SAI 015 TWD 43 015 VOL 001 SAI UTE TWD 69 UTE TEA UTE TWD 4 003 VOL 014 TEA UTE TEA UTE TEA UTE TEA UTE TEA UTE VOL 015

+

TEA UTE TEA UTE VOL 014

+

SAI 015 TWD 86 015 DNT LTS 4

VOL 011 4

SAI UTE TWD 99 UTE TWD 13 010

+

TEA UTE TEA UTE TEA UTE TEA UTE TEA UTE SAI UTS TWD 65 UTS MAI UTS TWD 60 UTS TWD 83 UTS VOL 013 VOL 003 TEA UTE DNT LTS

+

TWD 16 010

+

VOL 015

+

TEA UTE VOL 011 DNT LTE 4

-0.19

+3.11

+3.11

+14.17

-4.96

+14.28

-0.18

-0.67

-0.17

-0.18

+0.66

+7.07

-0.18

-0.20

-0.18

-0.19

+2.57 F23.93

+23.93

+36.17

-0.21

+0.57

-0.12

-0.19

-0.11

-15.67

-5.18

-0.20

-9.92

-0.17

-2.00

-2.00

-3.45

-3.45

-5.93

-0.33

-0.33

-0.22

-0.73

-11.59

-0.14

-0.17

-0.16

-0.13

-0.16

+0.59

-0.18

-0.28

+11.31

-5.56

-5.56

+1.04

+4.84

-3.73

-3.73

+0.68

-0.25

-0.15

-0.17

-0.16

-0.15

-8.09 8.09 7.13 7.13

-7.13

-9.24

-0.76

-0.14

+1.23

+0.69

+0.75

-0.23

-2.82 1.90 EXT UTE UTS UTS 010 012 010 UTE 009 UTE UTE 003 001 UTE UTE UTE UTE 011 012 012 003 UTE 010 UTE UTE UTE UTE 008 UTE 002 UTE 015 015 015 015 001 UTE UTE UTE 003 014 UTE UTE UTE UTE UTE 015 UTE UTE 014 015 015 LTS 011 UTE UTE 010 UTE UTE UTE UTE UTE UTS UTS UTS UTS UTS 013 003 UTE LTS 010 015 UTE 011 LTE EXT UTE UTS UTS 010 012 010 UTE 009 UTE UTE 003 001 UTE UTE UTE UTE 011 012 012 003 UTE 010 UTE UTE UTE UTS 008 UTE 002 UTE 015 015 015 015 001 UTE UTE UTE 003 014 UTE UTE UTE UTE UTE 015 UTE UTE 014 015 015 LTS 011 UTS UTS 010 UTE UTE UTE UTE UTE UTS UTS UTS UTS UTS 013 003 UTE LTS 010 015 UTE 011 LTE UTIL 1 UTIL 2 CAL #

2055 4036 4036 4036 4012 4012 2062 WAR 4012 2062 2055 WAR 4014 4012 2034 2033 2056 2055 4011 4012 4012 4012 2056 4036 2056 2055 2056 4055 4036 2052 4036 2052 4033 4033 4033 4033 4036 CL/CS 2052 2052 2051 WAR 4011 4011 2052 2051 2052 2052 2052 4036 2034 2033 4043 4043 4043 4043 4011 TR 2052 2052 WAR 4033 2052 2052 2052 2051 2052 4036 4036 4036 4036 4036 4011 4011 2062 4043 WAR 4033 4036 2052 4036 4043 LEG INLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET INLET INLET OUTLET OUTLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET INLET INLET INLET INLET OUTLET INLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET OUTLET OUTLET INLET INLET INLET INLET INLET OUTLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET OUTLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET PROBE 4 60HR 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460HR 460HR 460SI 460SI 4 60HR 460HR 460HR 460HR 460SI 460SI 460SI 460SI 4 60HR 460SI 4 60HR 4 60HR 4 60HR 460SI 460SI 460HR 460SI 460HR 460SI 460SI 460SI 460SI 460SI 4 60HR 460HR 460HR 460SI 460SI 460HR 4 60HR 4 60HR 460HR 4 60HR 460SI 460HR 4 60HR 460SI 460SI 460SI 460SI 460SI 4 60HR 460HR 460SI 460HR 460HR 460HR 460HR 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460HR 460SI 460SI

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:29:51 Component: S/G A Page 24 of 31 ATTACHMENT #3 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS 4.68 0.13 0.12 0.26 125 100 11.58 126 2 0.13 126 4 1.05 126 5 0.67 126 15 1.24 126 22 0.95 126 91 0.15 127 5 0.87 127 7 0.87 127 23 0.90 127 30 0.25 5.81 127 44 1.68 127 65 0.09 0.09 127 75 0.07 127 84 2.60 127 85 2.80 127 92 0.18 0.30 128 4 0.79 128 15 2.27 128 18 5.67 128 36 1.20 128 42 0.08 0.08 0.14 0.14 0.08 0.08 0.06 0.06 0.08 0.08 128 43 0.99 128 54 0.88 128 74 0.11 129 12 2.08 129 25 0.28 129 27 0.24 129 75 10.44 129 83 1.11 129 86 0.11 129 89 0.10 0.10 0.07 0.07 0.09 0.09 129 92 0.20 0.20 129 94 7.41 130 1 0.43 130 2 0.23 130 4 0.45 130 6 0.51 130 11 0.08 130 26 0.20 130 42 0.71 130 82 1.41 131 5 0.45 131 36 0.08 131 39 0.08 0.08 0.87 2.85 131 40 0.67 131 68 0.19 131 80 0.24 131 83 0.14 0.14 DEG 191 41 68 69 186 72 80 65 15 14 75 100 15 15 120 170 20 49 53 55 22 29 59 110 83 16 167 20 75 75 79 79 62 62 76 76 52 52 10 16 53 18 77 125 359 23 81 65 65 129 129 70 70 69 69 3

99 93 147 120 59 127 18 28 71 74 69 69 21 21 23 53 69 70 70 CHN IND 1

DNT 2

VOL 2

VOL P 3 TWD 1

DNT 2

VOL P 3 TWD P 3 TWD 2

TEA 2

TEA 2

VOL P 3 TWD 2

TEA 2

TEA 2

VOL 1

DNT 2

TEA 2

VOL 2

VOL 2

VOL 2

TEA 2

TEA P 3 TWD P 3 TWD P 3 TWD 2

TEA 1

DNT 2

TEA 2

SAI 2

TWD 2

SAI 2

TWD 2

SAI 2

TWD 2

SAI 2

TWD 2

SAI 2

TWD 2

TEA 2

TEA 2

VOL 2

TEA 2

VOL 2

VOL 1

DNT 2

TEA 2

VOL 2

SAI 2

TWD 2

SAI 2

TWD 2

SAI 2

TWD 2

SAI 2

TWD 1

DNT 2

VOL 2

VOL 2

VOL 2

VOL 2

VOL 2

VOL 2

TEA 2

TEA 2

VOL 2

VOL 2

SAI 2

TWD 2

TEA 2

TEA 2

TEA 2

VOL 2

VOL 2

SAI 2

TWD

%TW LOCATION LTE

+6.39 011

-12.66 011

-11.22 6

011

+0.69 LTS

+1.10 UTS

+12.47 16 010

+0.57 10 010

+0.49 UTE

-0.26 UTE

-0.20 013

+1.06 11 010

+0.57 UTE

-0.14 UTE

-0.22 014

+0.48 UTS

-19.35 UTE

-0.22 009

-16.43 009

+5.01 014

-11.80 UTE

-0.18 UTE

-0.17 4

009

+0.60 6

009

-0.71 12 010

+0.33 UTE

-0.20 001

-22.03 UTE

-0.10 UTS

-6.56 26 UTS

-6.56 UTS

-5.66 12 UTS

-5.66 UTS

-5.04 58 UTS

-5.04 UTS

-4.38 23 UTS

-4.38 UTS

-3.98 75 UTS

-3.98 UTE

-0.15 UTE

-0.19 015

-1.53 UTE

-0.17 015

-0.84 003

-0.73 006

+17.08 UTE

-0.19 UTS

-21.03 013

+4.15 60 013

+4.15 014

-11.70 0

014

-11.70 014

-7.75 43 014

-7.75 011

+7.05 39 011

+7.05 LTE

+3.41 013

+3.12 011

+6.11 010

+0.62 010

+0.62 012

-18.50 014

+0.45 UTE

-0.20 UTE

-0.10 009

+0.36 014

+0.96 UTS

-5.52 43 UTS

-5.52 UTE

-0.33 UTE

-0.33 UTE

-0.16 015

+14.67 012

-2.63 010

+9.14 43 010

+9.14 EXT LTE 011 011 011 LTS UTS 010 010 UTE UTE 013 010 UTE UTE 014 UTS UTE 009 009 014 UTE UTE 009 009 010 UTE 001 UTE UTS UTS UTS UTS UTS UT S UT S UTS UT S UT S UTE UTE 015 UTE 015 003 006 UTE UTS 013 013 014 014 014 014 010 010 LTE 013 011 010 010 012 014 UTE UTE 009 014 UTS UTS UTE UTE UTE 015 012 010 010 EXT LTE 011 011 011 LTS UTS 010 010 UTE UTE 013 010 UTE UTE 014 UTS UTE 009 009 014 UTE UTE 009 009 010 UTE 001 UTE UTS UT S UT S UTS UTS UTS UTS UTS UTS UTS UTE UTE 015 UTE 015 003 006 UTE UTS 013 013 014 014 014 014 011 011 LTE 013 011 010 010 012 014 UTE UTE 009 014 UTS UTS UTE UTE UTE 015 012 010 010 UTIL 1 UTIL 2 WAR WAR WAR WAR WAR WAR WAR IDOK CAL #

4043 4010 4010 4010 4014 4033 4033 4033 2051 2051 4014 4036 2051 2051 4036 4036 2052 4010 4010 4010 2034 2033 4014 4014 4033 2052 4036 2051 4036 4036 4036 4036 4036 4036 4036 4036 4036 4036 2051 2034 4010 2051 4036 4036 4010 2034 4010 4010 4010 4010 4010 4010 4010 4012 4012 4012 4055 4033 4036 4036 4036 4036 2051 2037 4036 4036 4036 4036 2047 2090 2048 4010 4010 4010 4010 LEG OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET OUTLET OUTLET INLET INLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET INLET INLET OUTLET OUTLET OUTLET INLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET OUTLET INLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET PROBE 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460HR 460SI 460SI 460HR 4 60HR 460SI 460SI 4 60HR 460SI 460SI 460SI 4 60HR 4 60HR 460SI 460SI 460SI 460HR 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460HR 460SI 460HR 460SI 460SI 460SI 4 60HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 4 60HR 4 60HR 460SI 460SI 460SI 460SI 460HR 460HR 460HR 460SI 460SI 460SI 460SI

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:29:51 Component: S/G A Page 25 of 31 ATTACHMENT #3 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

=

= = =

=

=

=

=

= = = = = = = ==

=

=

= = =

= = = = = = = =

=

0.10 0.10 0.09 0.09 0.10 0.10 0.05 0.05 0.08 0.08 0.08 0.08 0.07 0.07 0.06 0.06 0.06 0.06 0.09 0.09 0.08 0.08 0.12 0.12 0.10 0.10 0.09 0.09 0.09 0.09 O 0 9 O 0 9

0. 07 0.07 0.16 0.16 0.12 0.12 0.12 0.12 0.11 0.11 0.15 0.15 0.13 0.13 0.12 0.12 0.10 0.10 0.08 0.08 0.09 0.09
0. 12
0. 12
0. 12 0.12 0.06 0.06 0.13 0.13 131 85 0.64 0.11 0.11 0.15 0.15 0.12 0.12 0.08 0.08 0.08 0.08
0. 09
0. 09 67 2

67 2

66 2

66 2

103 2 103 2 88 2

88 2

80 2

80 2

98 2

98 2

55 2

55 2

118 2 118 2 104 2 104 2 92 2

92 2

105 2 105 2 70 2

70 2

86 2

86 2

88 2

88 2

100 2 100 2 71 2

71 2

77 2

77 2

70 2

70 2

86 2

86 2

92 2

92 2

66 2

66 2

92 2

92 2

82 2

82 2

89 2

89 2

82 2

82 2

75 2

75 2

89 2

89 2

78 2

78 2

83 2

83 2

121 2 121 2 77 2

77 2

18 2

77 2

77 2

64 2

64 2

65 2

65 2

9.5 2 95 2

94 2

94 2

60 2

60 2

SAI TWD 54 SAI TWD 57 SAI TWD 0 SAI TWD 0 SAI TWD 0 SAI TWD 0 SAI TWD 80 SAI TWD 0 SAI TWD 0 SAI TWD 0 SAI TWD 0 SAI TWD 43 SAI TWD 0 SAI TWD 0 SAI TWD 0 SAI TWD 39 SAI TWD 0 SAI TWD 43 SAI TWD 0 SAI TWD 0 SAI TWD 57 SAI TWD 0 SAI TWD 0 SAI TWD 0 SAI TWD 0 SAI TWD 16 SAI TWD 0 SAI TWD 0 SAI TWD 0 SAI TWD 0 SAI TWD 0 TEA SAI TWD 0 SAI TWD 63 SAI TWD 60 SAI TWD 0 SAI TWD 0 SAI TWD 71 010 010 010 010 010 010 010 010 010 010 010 010 010 010 010 010 010 010 012 012 012 012 012 012 012 012 012 012 012 012 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 UTE 010 010 010 010 010 010 010 010 010 010 010 010

-20.09

-20.09

-19.07

-19.07

-17.73

-17.73

-11. 99

-11. 99

-5.09

-5.09

-4.29

-4.29

-2.68

-2.68

-2.11

-2.11

-1.32

-1.32

-13.22

-13.22

-10. 97

-10.97

-9.64

-9.64

-8.53

-8.53

-7.42

-7.42

-5.52

-5.52

-25.79

-25.79

-25.36

-25.36

-23.45

-23.45

-23.79

-23.79

-21.23

-21.23

-20.26

-20.26

-18. 98

-18. 98

-18.06

-18.06

-14.52

-14.52

-13.50

-13.50

-12.31

-12.31

-11.34

-11.34

-8. 99

-8. 99

+4.54

+4.54

+8.97

+8. 97

-27.22

-27.22

-0.21

+6.13

+6.13

+7.84

+7.84

+8.23

+8.23

+9.41

+9.41

+10. 40

+10. 40

+11.57

+11.57 010 010 010 010 010 010 010 010 010 010 010 010 010 010 010 010 010 010 010 010 010 010 010 010 010 010 010 010 010 010 010 010 010 010 010 010 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 UTE UTE 010 010 010 010 010 010 010 010 010 010 010 010 010 010 010 010 010 010 010 010 010 010 010 010 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 2061 INLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4 60SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 4 60SI 460SI 460SI 460SI 4 60SI 4 60SI 460SI 460SI 460SI 4 60SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 4 60SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 4 60HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:29:52 Component: S/G A Page 26 of 31 ATTACHMENT #3 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS 0.16 0.16 0.11 0.11 0.13 0.13 0.14 0.14 0.09 0.09 0.09 0.09 0.12 0.12 0.09 0.09 0.19 0.19 0.06 0.06 0.12 0.12 0.12 0.12 0.10 0.10 0.13 0.13 131 86 0.31 4.44 0.09 0.09 0.05 0.05 0.05 0.05 0.11 0.11 0.10 0.10 0.12 0.12 0.10 0.10 0.11 0.11 0.09 0.09 0.10 0.10 0.06 0.06 0.13 0.13 0.07 0.07 0.12 0.12 0.16 0.16 0.11 0.11 0.12 0.12 0.11 0.11 131 87 3.30 0.38 0.38 0.34 0.34 0.39 0.39 0.35 0.35 DEG CHN IND %TW LOCATION 64 2

SAI 010

+12.49 64 2

TWD 63 010

+12.49 64 2

SAI 010

+13.73 64 2

TWD 63 010

+13.73 75 2

SAI 010

+14.73 75 2

TWD 16 010

+14.73 41 2

SAI 010

+15.63 41 2

TWD 94 010

+15.63 84 2

SAI 011

-11.26 84 2

TWD 0 011

-11.26 127 2 SAI 011

-9.04 127 2 TWD 0 011

-9.04 90 2

SAI 011

-7.99 90 2

TWD 0 011

-7.99 81 2

SAI 011

-6.82 81 2

TWD 0 011

-6.82 82 2

SAI 011

-5.70 82 2

TWD 0 011

-5.70 86 2

SAI 011

-4.97 86 2

TWD 0 011

-4.97 97 2

SAI 011

-3.61 97 2

TWD 0 011

-3.61 79 2

SAI 011

-2.61 79 2

TWD 0 011

-2.61 63 2

SAI 011

-1.60 63 2

TWD 65 011

-1.60 58 2

SAI 011

+3.11 58 2

TWD 75 011

+3.11 98 2

VOL UTE

-2.45 8

1 DNT LTE

+3.89 90 2

SAI 012

-4.03 90 2

TWD 0 012

-4.03 118 2 SAI 012

+4.69 118 2 TWD 0 012

+4.69 109 2 SAI 012

+5.77 109 2 TWD 0 012

+5.77 76 2

SAI 012

+6.95 76 2

TWD 9 012

+6.95 108 2 SAI 012

+11.48 108 2 TWD 0 012

+11.48 126 2 SAI 012

+12.31 126 2 TWD 0 012

+12.31 77 2

SAI 012

+12.99 77 2

TWD 0 012

+12.99 56 2

SAI 012

+13.82 56 2

TWD 78 012

+13.82 69 2

SAI 012

+14.70 69 2

TWD 47 012

+14.70 104 2 SAI 012

+18.95 104 2 TWD 0 012

+18.95 101 2 SAI 012

+20.04 101 2 TWD 0 012

+20.04 73 2

SAI 012

+22.13 73 2

TWD 29 012

+22.13 75 2

SAI 012

+23.38 75 2

TWD 16 012

+23.38 76 2

SAI 012

+23.86 76 2

TWD 9 012

+23.86 64 2

SAI 012

+24.93 64 2

TWD 63 012

+24.93 47 2

SAI 012

+25.76 47 2

TWD 89 012

+25.76 62 2

SAI 012

+26.47 62 2

TWD 67 012

+26.47 70 2

SAI 012

+28.55 70 2

TWD 43 012

+28.55 8

1 DNT LTE

+5.56 66 2

SAI 010

+8.40 66 2

TWD 49 010

+8.40 68 2

SAI 010

+9.58 68 2

TWD 42 010

+9.58 52 2

SAI 010

+10.93 52 2

TWD 79 010

+10.93 68 2

SAI 010

+11.44 68 2

TWD 42 010

+11.44 EXT 010 010 010 010 010 010 010 010 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 UTE LTE 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 LTE 010 010 010 010 010 010 010 010 EXT 0=10 010 010 010 010 010 010 010 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 UTE LT S 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 013 LTE 010 010 010 010 010 010 010 010 UTIL 1 UTIL 2 CS CAL #

4 010 4010 4010 4010 4010 4010 4010 4010 4010 4010 4010 4010 4010 4010 4010 4010 4010 4010 4010 4010 4010 4010 4010 4010 4010 4010 4010 4010 2061 4010 4010 4010 4010 4010 4010 4010 4010 4010 4010 4010 4010 4010 4010 4010 4010 4010 4010 4010 4010 4010 4010 4010 4010 4010 4010 4010 4010 4010 4010 4010 4010 4010 4010 4010 4010 4010 4012 4012 4012 4012 4012 4012 4012 4012 4012 LEG OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET PROBE 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:29:52 Component: S/G A Page 27 of 31 ATTACHMENT #3 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS 0.40 0.40 0.18 0.18 131 90 0.11 0.11 0.09 0.09 0.11 0.11 0.13 0.13 0.07 0.07 0.11 0.11 0.16 0.16 0.15 0.15 0.18 0.18 0.16 0.16 0.12 0.12 0.12 0.12 0.14 0.14 0.10 0.10 132 12 1.32 132 29 10.40 132 33 0.10 132 75 0.23 132 80 0.21 132 81 5.28 132 82 0.61 0.09 0.09 0.09 0.09 0.13 0.13 0.16 0.16 0.10 0.10 133 26 0.13 0.12 133 39 0.86 133 62 0.24 0.22 133 83 0.13 0.13 0.12 0.12 0.13 0.13 0.18 0.18 133 85 0.12 0.12 0.07 0.07 0.07 0.07 134 9 0.95 134 27 12.64 134 29 0.16 0.16 0.15 0.15 0.08 DEG 66 66 59 59 74 74 89 89 80 80 94 94 89 89 83 83 76 76 66 66 67 67 63 63 58 58 72 72 72 72 76 76 15 180 83 65 87 352 76 68 68 71 71 80 80 80 80 63 63 72 76 24 118 118 102 102 85 85 91 91 65 65 75 75 76 76 56 56 19 182 84 84 70 71 61 CHN 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

1 2

2 2

1 P3 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 1

2 2

2 2

2 IND %TW SAI TWD 49 SAI TWD 67 SAI TWD 16 SAI TWD 0 SAI TWD 0 SAI TWD 0 SAI TWD 0 SAI TWD 0 SAI TWD 3 SAI TWD 49 SAI TWD 46 SAI TWD 57 SAI TWD 69 SAI TWD 26 SAI TWD 26 SAI TWD 3 TEA DNT VOL VOL VOL DNT TWD 13 SAI TWD 51 SAI TWD 39 SAI TWD 0 SAI TWD 0 SAI TWD 65 SAI TWD 23 TEA VOL VOL SAI TWD 0 SAI TWD 0 SAI TWD 0 SAI TWD 67 SAI TWD 34 SAI TWD 29 SAI TWD 82 TEA DNT SAI TWD 0 SAI TWD 37 SAI LOCATION 010

+12.29 010

+12.29 011

-7.45 011

-7.45 012

-18.97 012

-18.97 012

-15.02 012

-15.02 012

-14.56 012

-14.56 012

-13.63 012

-13.63 012

-13.08 012

-13.08 012

-12.25 012

-12.25 012

-11.37 012

-11.37 012

-5.70 012

-5.70 012

-4.65 012

-4.65 012

-3.39 012

-3.39 012

-2.19 012

-2.19 012

+6.13 012

+6.13 012

+7.35 012

+7.35 012

+12.45 012

+12.45 UTE

-0.15 003

+2.32 014

+1.12 008

+11.37 008

-0.65 LTE

+3.01 009

+0.60 010

+16.34 010

+16.34 010

+14.01 010

+14.01 010

+11.85 010

+11.85 010

+9.75 010

+9.75 010

+12.94 010

+12.94 015

-11.55 015

-11.55 UTE

-0.06 015

-0.45 015

-0.11 012

-2.52 012

-2.52 012

-6.01 012

-6.01 012

-8.85 012

-8.85 014

+4.33 014

+4.33 011

-5.33 011

-5.33 011

-6.79 011

-6.79 011

-14.61 011

-14.61 UTE

-0.06 003

+4.54 010

+16.58 010

+16.58 010

-10.10 TO-2.48 010

-10.10 TO-2.48 011

+18.72 TO+20.02 EXT 010 010 011 011 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 UTE 003 014 008 008 LTE 009 010 010 010 010 010 010 010 010 010 010 015 015 UTE 015 015 012 012 012 012 012 012 014 014 011 011 011 011 011 011 UTE 003 010 010 010 010 011 EXT 010 010 011 011 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 012 UTE 003 014 008 008 LTE 009 010 010 010 010 010 010 010 010 010 010 015 015 UTE 015 015 012 012 012 012 012 012 014 014 011 011 011 011 011 011 UTE 003 010 010 010 010 011 UTIL 1 UTIL 2 WAR CAL # LEG 4012 OUTLET 4012 OUTLET 4012 OUTLET 4012 OUTLET 4012 OUTLET 4012 OUTLET 4012 OUTLET 4012 OUTLET 4012 OUTLET 4012 OUTLET 4012 OUTLET 4012 OUTLET 4012 OUTLET 4012 OUTLET 4012 OUTLET 4012 OUTLET 4012 OUTLET 4012 OUTLET 4012 OUTLET 4012 OUTLET 4012 OUTLET 4012 OUTLET 4012 OUTLET 4012 OUTLET 4012 OUTLET 4012 OUTLET 4012 OUTLET 4012 OUTLET 4012 OUTLET 4012 OUTLET 4012 OUTLET 4012 OUTLET 2048 INLET 4036 OUTLET 4036 OUTLET 4010 OUTLET 4010 OUTLET 4043 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4010 OUTLET 4036 OUTLET 4036 OUTLET 2047 INLET 4010 OUTLET 4010 OUTLET 4009 OUTLET 4009 OUTLET 4009 OUTLET 4009 OUTLET 4009 OUTLET 4009 OUTLET 4009 OUTLET 4009 OUTLET 4009 OUTLET 4009 OUTLET 4009 OUTLET 4009 OUTLET 4009 OUTLET 4009 OUTLET 2047 INLET 4036 OUTLET 4036 OUTLET 4036 OUTLET 4036 OUTLET 4036 OUTLET 4036 OUTLET PROBE 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 4 60HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460SI

Framatome ANP Inc.

Customer Name: Oconee Unit 3 ATTACHMENT #3 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl 12/05/01 14:29:52 Component: S/G A Page 28 of 31 ROW TUBE VOLTS 0.08 134 32 0.17 134 37 0.17 0.15 0.14 0.13 0.13 0.16 0.16 134 38 0.22 0.24 0.12 0.12 0.19 0.19 0.26 0.26 0.22 0.22 0.10 0.10 0.22 0.22 134 66 0.98 134 67 1.98 134 84 0.19 134 85 2.55 135 3 0.26 135 22 0.15 0.15 135 26 0.19 0.20 135 28 2.43 2.08 2.88 135 35 1.55 135 56 3.16 135 65 1.82 135 73 3.00 135 75 0.08 0.19 135 79 0.08 0.08 0.10 0.10 135 80 3.85 3.69 136 3 0.75 136 15 2.60 136 20 0.15 136 25 2.91 6.54 7.25 136 29 0.23 136 44 0.19 136 54 0.14 136 61 0.08 136 74 1.95 136 76 0.47 136 80 0.17 0.17 137 3 0.72 137 22 6.21 8.19 137 24 5.45 6.35 137 27 0.14 0.14 0.07 0.07 0.13 0.13 0.14 0.15 0.09 DEG 61 57 48 73 73 81 81 38 38 60 59 69 69 82 82 71 71 74 74 111 111 73 73 17 28 105 0

72 69 66 65 60 188 188 185 21 186 28 196 70 74 62 62 72 72 173 167 73 16 109 184 183 179 71 35 77 117 171 98 72 72 66 181 176 182 181 36 36 75 75 51 51 45 51 40 CHN 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 1

2 2

2 2

2 1

1 1

2 1

2 1

2 2

2 2

2 2

1 1

P3 2

2 P3 1

1 2

2 2

2 1

P3 2

2 P3 1

1 1

1 2

2 2

2 2

2 2

2 2

IND %TW TWD 60 VOL VOL SAI TWD 32 SAI TWD 5 SAI TWD 92 SAI TWD 64 SAI TWD 43 SAI TWD 0 SAI TWD 37 SAI TWD 29 SAI TWD 0 SAI TWD 32 TEA TEA VOL DNT VOL SAI TWD 50 SAI TWD 62 DNT DNT DNT TEA DNT TEA DNT VOL VOL SAI TWD 73 SAI TWD 47 DNT DNT TWD 12 TEA VOL DNT DNT DNT VOL VOL VOL VOL DNT TWD 12 SAI TWD 47 TWD 10 DNT DNT DNT DNT SAI TWD 100 SAI TWD 26 SAI TWD 77 SAI TWD 77 SAI LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG

=

=

==

=

==

=

==

=

==

=

=

==:--

011 007 010 012 012 012 012 012 012 UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS UTE UTE 010 LTS 004 008 008 013 013 LTE LTE LTE UTE LTS UTE LTS 008 008 013 013 014 014 LTE LTE 014 UTE 014 003 003 004 015 010 006 009 LTS 009 013 013 010 003 003 003 003 012 012 012 012 012 012 012 012 012

+18.72 TO+20.02

+17.45

+15.08

-12.85

-12.85

-15.33 TO-18.05

-15.33 TO-18.05

-19.23

-19.23

-13.03

-13.03

-11.23

-11.23

-6.49

-6.49

-2.82

-2.82

-2.32

-2.32

-1.93

-1.93

-1.22

-1.22

-0.19

-0.10

+0.65

+1.30

+18.97

-1.34

-1.34

-5.57

-5.57

+2.07

+3.43

+4.77

-0.30

-17.12

-0.08

-20.67

-1.74

-14.43

+2.21

+2.21

-17.50

-17.50

+2.70

+4.24

-0.72

-0.34

+0.36

+0.27

+1.78

-3.15

+0.50

+14.26

+7.85

+2.38

-17.18

-0.59

-15.94

-15.94

-0.66

+2.23

+2.63

+1.75

+4.01

-12.33

-12.33

-11.28

-11.28

-9.05

-9.05

-4.73

-4.73

-1.84 011 007 010 012 012 012 012 012 012 UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS UTE UTE 010 LTS 004 008 008 013 013 LTE LTE LTE UTE LTS UTE LTS 008 008 013 013 014 014 LTE LTE 014 UTE 014 003 003 004 015 010 006 009 LTS 009 013 013 010 003 003 003 003 012 012 012 012 012 012 012 012 012 011 007 010 012 012 012 012 012 012 UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS UTE UTE 010 LTS 004 008 008 013 013 LTS LTS LTS UTE LTS UTE LTS 008 008 013 013 014 014 LTE LTE 014 UTE 014 003 003 004 015 010 006 009 LTS 009 013 013 010 003 003 003 003 012 012 012 012 012 012 012 012 012 4036 4036 4036 4036 4036 4036 4036 4036 4036 4036 4036 4036 4036 4036 4036 4036 4036 4036 4036 4036 4036 4036 4036 2038 2037 4009 4012 4036 4036 4036 4036 4036 4036 4036 4036 2047 4009 2037 4009 4009 4009 4009 4009 4009 4009 4012 4012 4036 2090 4036 4036 4036 4036 4036 4009 4009 4009 4009 4009 4009 4009 4036 4036 4036 4036 4036 4036 4036 4036 4036 4036 4036 4036 4036 4036 OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET PROBE 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 4 60HR 4 60HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 4 60HR 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 4 60HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI WAR WAR WAR

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:29:52 Component: S/G A Page 29 of 31 ATTACHMENT #3 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS 0.10 137 60 0.57 137 61 0.26 137 66 2.55 137 70 1.25 0.07 0.07 137 77 20.72 0.61 0.15 0.15 19.14 0.36 0.17 0.17 137 78 12.32 0.60 0.30 0.29 138 3 1.75 138 4 0.13 138 11 0.07 138 18 0.18 138 43 1.30 138 44 0.12 138 49 0.16 138 51 2.37 138 62 1.69 138 63 3.17 138 70 10.71 5.47 138 75 0.07 0.07 0.10 0.10 0.06 0.06 0.08 0.08 16.79 139 3 0.51 139 5 0.30 139 20 0.17 139 24 6.29 5.69 4.23 3.52 2.69 139 32 0.74 139 39 1.01 139 43 0.06 139 60 2.45 2.45 139 66 1.58 139 70 0.10 140 1 0.60 0.70 140 3 0.83 140 5 0.24 140 31 1.40 140 42 0.81 140 56 1.10 140 69 2.77 140 71 9.83 141 1 1.13 0.58 141 24 3.02 4.85 4.51 4.96 2.31 2.98 3.63 3.59 3.65 DEG 40 151 21 187 165 69 69 184 131 76 76 2

147 58 58 358 88 65 65 18 27 47 47 24 102 9

24 17 26 171 359 90 90 68 68 84 84 99 99 157 79 120 65 6

7 2

7 14 43 16 47 18 18 17 34 145 124 120 316 15 11 9

145 354 42 91 178 174 177 192 188 185 192 196 192 CHN 2

2 2

1 1

2 2

1 2

2 2

1 2

2 2

1 P3 2

2 2

2 2

2 2

2 2

2 2

2 1

1 2

2 2

2 2

2 2

2 1

P 3 2

2 1

1 1

1 1

2 2

2 2

2 2

2 P 3 P3 P 3 2

2 2

2 1

1 P 3 P 3 1

1 1

1 1

1 1

1 1

IND %TI TWD 90 VOL VOL DNT DNT SAI TWD 57 DNT VOL SAI TWD 3 DNT VOL SAI TWD 69 DNT TWD 13 SAI TWD 52 TEA VOL VOL VOL TEA VOL VOL TEA TEA TEA DNT DNT SAI TWD 74 SAI TWD 85 SAI TWD 77 SAI TWD 69 DNT TWD 8 VOL VOL DNT DNT DNT DNT DNT TEA TEA VOL SAI TWD 62 TEA VOL TWD 18 TWD 20 TWD 13 VOL TEA TEA TEA DNT DNT TWD 17 TWD 9 DNT DNT DNT DNT DNT DNT DNT DNT DNT q LOCATION

=========

012 004 015 LTE LTS 015 015 LTS 010 t

011 011 LTS t

010 t

011 011 LTS 010 013 013 UTE 002 013 t

LTS t

UTE 008 003 UTE UTE UTE 008 010 010

+

010

+

010

+

010

+

010

+

010

+

010

+

010

+

LTS

+

010

+

008 011 LTE 4

LTE

+

LTE 4

LTE 4

LTE 4

UTE UTE 015 4

UTE UTE UTE LTS 4

012 011 010 009 UTE UTE UTE LTE 4

LTS 4

014 014 LTE 4

LTE 4

LTE 4

LTE 4

LTE 4

LTE 4

LTE 4

LTE 4

LTE 4

-1.84

-0.73

+0.18

+3.26

-20.60

+7.89

+7.89

+1.04

+0.23

-3.63

-3.63

+1.07

-0.23

-3.59

-3.59

+1.25

-0.34

-8.41

-8.41

-0.29

-16.57

+5.04

+20.16

-0.08

-0.14

-10.71

-0.16

-0.19

-0.07

-0.20

-8.67

-14.00

-14.00

-14.19

-14.19

-16.81

-16.81

-21.12

-21.12

-0.62

-0.41

-0.28

-4.51

-2.96

-3.17

-3.35

-3.62

-4.58

-0.15

-0.22

-4.74

-0.31

-0.31

-0.23

-4.30

-0.62

-0.79

-0.48

-0.90

-0.29

-0.22

-0.19

-2.18

-1.20

-0.82

-0.51

-23.11

+1.90

+3.07

+4.14

+4.96

+5.23

+6.56

+6.97

+7.23 EXT 012 004 015 LTE LTS 015 015 LTS 010 011 011 LTS 010 011 011 LTS 010 013 013 UTE 002 013 LTS UTE 008 003 UTE UTE UTE 008 010 010 010 010 010 010 010 010 010 LTS 010 008 011 LTE LTE LTE LTE LTE UTE UTE 015 UTE UTE UTE LTS 012 011 010 009 UTE UTE UTE LTE LTS 014 014 LTE LTE LTE LTE LTE LTE LTE LTE LTE EXT 012 004 015 LTE LTS 015 015 LTS 010 011 011 LTS 010 012 012 LTS 010 013 013 UTE 002 013 LTS UTE 008 003 UTE UTE UTE 008 010 010 010 010 010 010 010 010 010 LTS 010 008 011 LTS LTS LTS LTS LTS UTE UTE 015 UTE UTE UTE LTS 012 011 010 009 UTE UTE UTE LTS LTS 014 014 LTS LTS LTS LTS LTS LTS LTS LTS LTS UTIL 1 UTIL 2 CAL #

4036 4009 4009 4043 4009 4009 4009 4012 IDOK 4012 4012 4012 4009 4009 4009 4009 4012 WAR 4012 4012 4012 2046 4033 4036 4036 2037 4009 4009 2037 2038 2037 4009 4009 4043 4043 4043 4043 4043 4043 4043 4043 4062 WAR 4033 4036 4036 4036 4036 4036 4036 4036 2045 2038 4009 CL 2038 2038 2038 4009 WAR 4055 WAR 4055 WAR 4033 4033 2046 2038 2038 4009 4012 WAR 4033 WAR 4033 4030 4030 4030 4030 4030 4030 4030 4030 4030 LEG OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET OUTLET INLET INLET INLET OUTLET INLET INLET OUTLET OUTLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET PROBE 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460SI 4 60HR 460SI 460SI 460HR 4 60HR 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 4 60HR 460HR 460SI 460HR 460HR 4 60HR 460SI 460SI 460SI 460SI 460SI 4 60HR 460HR 4 60HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:29:53 Component: S/G A Page 30 of 31 ATTACHMENT #3 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS 3.70 3.79 1.75 3.56 4.77 1.23 2.65 2.95 2.42 3.26 141 46 0.14 141 55 0.27 141 59 0.45 141 68 2.32 142 1 0.81 142 8 0.77 142 12 0.19 142 41 0.19 142 48 0.52 0.52 142 53 0.21 142 54 0.22 142 61 0.16 143 3 0.88 143 8 0.69 143 27 0.07 0.06 143 38 0.30 143 47 0.17 0.17 0.14 0.14 4.69 0.20 0.20 143 49 9.97 0.09 143 60 6.70 143 61 0.03 0.03 0.07 0.07 144 11 4.14 144 13 0.18 144 31 0.52 0.52 144 46 0.14 144 48 12.26 144 49 0.31 144 53 0.18 145 1 0.64 145 16 0.28 145 23 0.54 145 24 1.24 0.15 145 36 0.31 145 47 0.50 146 8 5.61 6.16 14.05 6.69 6.62 146 13 0.30 146 14 0.75 146 20 0.19 0.19 146 22 0.05 0.05 146 24 1.15 146 29 0.61 146 34 0.10 146 37 0.07 0.05 146 43 13.75 9.87 DEG 188 189 192 185 189 208 193 182 168 186 30 61 103 10 62 20 36 68 19 19 87 103 170 27 25 69 47 44 97 97 80 80 5

44 44 185 88 183 112 112 108 108 353 50 75 88 88 184 29 128 27 58 23 26 101 59 60 187 178 177 177 175 116 34 81 81 102 105 17 28 78 64 73 184 185 CHN 1

1 1

1 1

1 1

1 1

1 2

P 3 P 3 1

P 3 23 2

2 2

2 2

2 2

P 3 P 3 2

2 2

2 2

2 2

1 2

2 1

2 1

2 2

2 2

1 2

2 2

2 1

P 3 2

P 3 P3 2

2 2

2 P 3 1

1 1

1 1

2 P3 2

2 2

2 2

P93 2

2 2

1 1

I ND DNT DNT DNT DNT DNT DNT DNT DNT DNT DNT VOL TWD TWD DNT TWD TWD VOL VOL SAI TWD VOL VOL VOL TWD TWD VOL VOL VOL SAI TWD SAI TWD DNT SAI TWD DNT VOL DNT SAI TWD SAI TWD DNT VOL VOL TWD VOL DNT TWD VOL TWD TWD TEA TEA VOL VOL TWD DNT DNT DNT DNT DNT VOL TWD SAI TWD VOL VOL TEA TWD VOL VOL VOL DNT DNT

%TW LOCATION LTE LTE LTE LTE LTE LTE LTE LTE LTE 001 6

015 9

008 LTE 16 014 15 008 014 014 UTE 58 UTE 008 015 A

014 A

17 014 16 008 A

013 H

013 H

004 013 H

70 013

+

013

+

79 013 H

LTE

+

UTS 84 UTS 003 013 4

LTE 4

015

+

4 015

+

015 H

6 015 H

003 4

011 4

001 4

22 001 4

013 4

003 4

5 008 008 4

13 013 6

008 UTE UTE UTS 4

014 8

008 4

003 4

003 4

003 4

003 4

003 4

008 4

15 008 011 4

28 011 4

008 4

009 4

UTE 9

008 013 010 010 003 003

  • 8.31
  • 8.13

+17.56

+18.70

+19.06

+20.33

+20.64

+21.08

+21.10

+21.39 F2.07

+0.31

-0.71

+4.52

-0.66

-0.42

+0.26

-7.20

-1.18

-1.18

-0.77

+0.28

+0.38

-0.73

+0.49

+12.60

+17.26

-17.57

-11.95

-11.95

-13.17

-13.17

-4.08

-14.43

-14.43

-1.82

-1.26

-2.70

-4.31

-4.31

-4.45

-4.45

-2. 65

-18.75

-0.65

+0.65

-0.84

-2.17

-0.49

+0.28

-0.70

-0.56

-0.23

-0.20

-3.70

-0.38

+0.63

-0.44

-1.49

+2.04

-2.76

-3.15

-0.76

-0.47

-13.23

-13.23

-3.58

-7.78

-0.19

-0.70

-1.94

-6.18

-5.78

-0.85

-4.37 EXT LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 001 015 008 LTE 014 008 014 014 UTE UTE 008 015 014 014 008 013 013 004 013 013 013 013 LTE UTS UTS 003 013 LTE 015 015 015 015 003 011 001 001 013 003 008 008 013 008 UTE UTE UTS 014 008 003 003 003 003 003 008 008 011 011 008 009 UTE 008 013 010 010 003 003 EXT UTIL 1 UTIL 2 CAL # LEG L=S 4030 OUTLET LTS 4030 OUTLET LTS 4030 OUTLET LTS 4030 OUTLET LTS 4030 OUTLET LTS 4030 OUTLET LTS 4030 OUTLET LTS 4030 OUTLET LTS 4030 OUTLET LTS 4030 OUTLET 001 4009 OUTLET 015 WAR 4009 OUTLET 008 WAR 4009 OUTLET LTE 4012 OUTLET 014 WAR 4030 OUTLET 008 WAR 4030 OUTLET 014 4030 OUTLET 014 4009 OUTLET UTE TR 2041 INLET UTE 2041 INLET 008 4009 OUTLET 015 4009 OUTLET 014 4009 OUTLET 014 WAR 4030 OUTLET 008 WAR 4030 OUTLET 013 4030 OUTLET 013 4030 OUTLET 004 4009 OUTLET 013 4043 OUTLET 013 4043 OUTLET 013 4043 OUTLET 013 4043 OUTLET LTS 4009 OUTLET UTS 4009 OUTLET UTS 4009 OUTLET 003 4043 OUTLET 013 4009 OUTLET LTS 4009 OUTLET 015 4008 OUTLET 015 4008 OUTLET 015 4008 OUTLET 015 4008 OUTLET 003 4030 OUTLET 011 4030 OUTLET 001 4008 OUTLET 001 4008 OUTLET 013 4008 OUTLET 003 4008 OUTLET 008 WAR 4008 OUTLET 008 4043 OUTLET 013 WAR 4030 OUTLET 008 WAR 4030 OUTLET UTE 2041 INLET UTE 2042 INLET UTS 4030 OUTLET 014 4043 OUTLET 008 WAR 4008 OUTLET 003 4030 OUTLET 003 4030 OUTLET 003 4030 OUTLET 003 4030 OUTLET 003 4030 OUTLET 008 4030 OUTLET 008 WAR 4030 OUTLET 011 4030 OUTLET 011 4030 OUTLET 008 4030 OUTLET 009 4030 OUTLET UTE 2042 INLET 008 WAR 4043 OUTLET 013 4008 OUTLET 010 4008 OUTLET 010 4008 OUTLET 003 4043 OUTLET 003 4043 OUTLET PROBE 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SR 460HR 460SI 460SI 460SI 460SI 460SI

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:29:53 Component: S/G A Page 31 of 31 ATTACHMENT #3 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS 0.52 146 45 13.09 3.32 146 46 6.90 147 5 0.15 147 11 0.44 147 12 0.30 147 21 0.04 0.05 0.11 0.11 0.11 147 24 1.58 147 27 0.15 147 28 0.30 147 42 0.18 148 10 0.21 148 41 8.85 149 1 0.11 149 8 0.57 149 15 8.26 149 16 0.32 149 25 0.44 0.37 149 30 0.12 150 3 0.21 150 4 1.10 150 8 0.46 150 9 0.30 150 12 0.59 150 14 0.28 0.63 150 19 0.39 151 3 0.59 151 4 0.18 151 5 2.85 0.58 1.21 0.51 151 7 0.26 151 9 0.34 0.85 151 16 0.41 DEG 109 2

177 178 55 115 112 59 86 60 62 62 23 60 164 151 9

188 53 118 182 71 118 115 46 28 15 74 92 39 77 144 118 17 60 23 125 27 29 138 116 21 100 CHN P 3 1

1 1

2 P 3 2

2 2

2 2

2 2

2 2

2 P 3 1

2 P 3 1

P 3 2

2 2

2 2

P 3 P 3 P3 2

P 3 2

P 3 2

2 P 3 P 3 P 3 2

2 2

2 IND TWD DNT DNT DNT VOL TWD VOL SAI TWD MAI TWD TWD TEA VOL VOL VOL TWD DNT VOL TWD DNT TWD VOL VOL VOL VOL TEA TWD TWD TWD VOL TWD VOL TWD VOL TEA TWD TWD TWD VOL VOL TEA VOL

%TW LOCATION 8

009 004 004 003 015 14 008 010 012 20 012 012 57 012 57 012 UTE 009 009 009 6

008 003 H

001 17 009 H

013 d

8 010 A

010

+

010

+

013

+

015

+

UTE 11 010

+

7 010 14 010 006

+

13 010

+

011 12 012 006 4

UTE 14 012 22 013 12 013 4

013 012 4

UTE 013 4

+0.53

-4.11

-1.41

+3.73

+4.26

+0.68

-0.78

-8.91

-8.91

-9.82

-9.82

-9.82

-0.24

-0.13

+0.40

+0.27

+0.69

+4.26

-10.47

+0.55

-2.53

-0.63

-0.34

-0.14

-0.98

-18.11

-0.19

-0.62

-0.65

-0.68

-0.69

-0.59

-0.17

-0.58

-0.57

-0.19

-0.74

-0.49

-0.73

-0.81

+0.63

-0.24

+4.18 EXT 009 004 004 003 015 008 010 012 012 012 012 012 UTE 009 009 009 008 003 001 009 013 010 010 010 013 015 UTE 010 010 010 006 010 011 012 006 UTE 012 013 013 013 012 UTE 013 EXT UTIL 1 009 WAR 004 004 003 015 008 WAR 010 012 012 012 012 012 UTE 009 009 009 008 WAR 003 001 009 WAR 013 010 WAR 010 010 013 015 UTE 010 WAR 010 WAR 010 WAR 006 010 WAR 011 012 WAR 006 UTE 012 WAR 013 WAR 013 WAR 013 012 UTE 014 UTIL 2 CAL # LEG 4008 OUTLET 4008 OUTLET 4008 OUTLET 4008 OUTLET 4030 OUTLET 40S5 INLET 4030 OUTLET 4030 OUTLET 4030 OUTLET 4030 OUTLET 4030 OUTLET 4030 OUTLET 2041 INLET 4007 OUTLET 4007 OUTLET 4007 OUTLET 4030 OUTLET 4043 OUTLET 4030 OUTLET 4055 INLET 4030 OUTLET 4030 OUTLET 4007 OUTLET 4007 OUTLET 4007 OUTLET 4030 OUTLET 2042 INLET 4030 OUTLET 4030 OUTLET 4030 OUTLET 4030 OUTLET 4030 OUTLET 4007 OUTLET 4030 OUTLET 4030 OUTLET 2042 INLET 4030 OUTLET 4030 OUTLET 4030 OUTLET 4030 OUTLET 4043 OUTLET 2041 INLET 4005 OUTLET PROBE 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460SI 4 60SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 4 60SI 4 60SI 460SI 460SI 460SI 460SI 460SI 460SI 4 60HR 460SI 4 60SI 460SI 460SI 460SI 460HR 460SI Total Tubes

1256 Total Records: 2293

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:32:38 Component: S/G B Page 1 of 20 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS 1

1 0.41 1

5 0.31 1

14 0.19 2

8 0.42 2

20 0.10 0.00 0.20 0.20 0.19 0.00 2

22 1.28 0.87 2.02 4.34 5.16 3.47 1.46 1.02 1.70 3

3 0.21 0.21 0.19 0.14 3

4 3.60 1.80 3

8 1.51 10.39 3

9 2.49 11.15 3

11 0.20 3

15 0.39 0.44 3

22 0.12 3

28 0.74 3

29 0.30 4

2 1.03 4

3 8.13 5.98 4

6 0.17 0.17 0.13 0.13 0.11 0.11 0.09 0.09 0.15 0.15 0.11 0.11 0.25 0.24 0.17 0.17 0.12 0.12 0.14 0.14 0.14 0.14 0.12 0.11 4

8 1.62 4

10 0.90 4

17 0.89 4

20 0.33 4

35 0.64 4

39 3.56 5

5 0.10 5

6 0.17 0.15 7.92 6.15 5

7 3.64 5

12 1.74 DEG 152 148 55 57 91 0

55 69 69 0

58 71 48 31 29 37 53 48 45 110 106 111 113 174 169 24 179 185 181 120 46 52 71 54 117 48 155 158 105 105 69 69 78 76 48 48 82 82 77 77 81 76 85 85 54 54 78 78 81 81 70 68 53 21 13 121 128 178 35 135 145 168 168 150 21 CB 2

2 2

2 P

p P

P P

P P

p P

P P

P P

P P

2 2

2 2

1 1

2 1

1 1

2 2

2 2

P 2

P 1

1 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 1

2 2

2 P

1 2

2 2

1 1

1 2

IN IND %Th VOL VOL VOL VOL 1 SCI 4 TWD 0 4 TWD 43 4 TWD 44 4 TWD 41 4 TWD 0 1 SCI 3 TWD 0 3 TWD 49 3 TWD 71 3 TWD 78 3 TWD 64 3 TWD 41 3 TWD 0 1 PID VOL TWD 0 VOL TWD 0 DNT DNT TEA DNT DNT DNT VOL VOL TWD 63 VOL 3 TWD 15 VOL 3 TWD 13 DNT DNT SAI TWD 0 SAI TWD 63 SAI TWD 51 SAI TWD 89 SAI TWD 39 SAI TWD 49 SAI TWD 51 SAI TWD 32 SAI TWD 83 SAI TWD 47 SAI TWD 41 SAI TWD 65 VOL DNT TEA VOL 3 TWD 15 DNT VOL VOL TWD 0 DNT DNT DNT TEA W LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 010 010 015 006 UTS UTS UTS UTS UTS UTS UTE UTE UTE UTE UTE UTE UTE UTE UTE UTS UTS 015 015 LTS LTS UTE 010 UTS 010 010 012 012 015 013 UTS 011 LTE UTS 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 010 010 UTE 009 010 UTS 005 014 014 LTE UTS UTS UTE

-0.24

-0. 10

-0.43

-16.79

-0.01

-0.01 TO+236.6

-0.01 TO+246.9

-0.01 TO+257.1

-0.01 TO+267.4

-0.01 TO+277.7

-0.18

-0.18 TO+130.9

-0.18 TO+122.7

-0.18 TO+114.5

-0.18 TO+106.4

-0.18 TO+98.2

-0.18 TO+90.0

-0.18 TO+81.8

-0.18

+0.44

+0.44

-0.71

-0.71

-9.95

-9.60

-0.20

-0.13

+0.05

-0.01

-2.36

+1.18

+1.18

+18.84

+0.73

-13.80

-0.74

+10. 90

+12.50

-1.26

-1.26

-1.56

-1.56

-2.69

-2.69

-2.81

-2.81

-3.80

-3.80

-4.18

-4.18

-4.97

-4.97

-6.03

-6.03

-6.26

-6.26

-6.92

-6.92

-10.51

-10.51

-11.90

-11.90

-1.81 TO-4.61

-0.16

-0.20

-0.59

+0.72

+0.02

-7.06

-0.25

-0.25

+10.83

+13.00

+12.21

-0.22 010 010 015 006 015 015 015 015 015 015 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTS UTS 015 015 LTS LTS UTE 010 UTS 010 010 012 012 015 013 UTS 011 LTS UTE 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 010 010 UTE 009 010 UTS 005 014 014 LTS UTE UTE UTE 010 010 015 006 UTS UTS UTS UTS UTS UTS UTE UTE UTE UTE UTE UTE UTE UTE UTE UTS UTS 015 015 LTS LTS UTE 010 UTS 010 010 012 012 015 013 UTS 011 LTE UTS 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 011 010 010 UTE 009 010 UTS 005 014 014 LTE UTS UTS UTE WAR WAR WAR 4019 4019 4020 4041 4020 4020 4020 4020 4020 4020 2064 2064 2064 2064 2064 2064 2064 2064 2121 4019 4019 4019 4019 4019 4019 2013 4019 4019 4019 4019 4019 4019 4020 4020 4020 4019 4026 4026 4019 4019 4019 4019 4019 4019 4019 4019 4019 4019 4019 4019 4019 4019 4019 4019 4019 4019 4019 4019 4019 4019 4019 4019 4019 4019 2013 4019 4020 4020 4019 4026 4026 4026 4026 4026 2013 INLET INLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 4 60HR

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:32:38 Component: S/G B Page 2 of 20 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 5

15 1.42 5

23 0.22 5

31 0.31 5

35 0.27 5

39 0.68 5

42 0.80 2.81 0.15 0.00 0.12 0.20 0.13 0.00 6

5 0.12 6

6 0.29 6

15 0.62 6

19 0.29 6

20 0.19 6

45 0.24 7

8 0.14 7

14 6.83 7

15 0.80 7

44 0.22 7

45 0.18 7

46 0.16 7

51 0.07 8

1 3.88 8

2 2.38 8

5 0.14

0. 10 8

10 0.50 8

12 1.22 8

13 0.17 8

21 0.17 8

42 0.34 8

47 0.41 8

48 0.29 9

1 0.80 9

2 0.90 9

5 0.97 9

6 0.80 9

23 0.41 9

24 0.72 9

56 0.36 10 2

0.41 10 4

1.34 10 6

2.22 2.84 2.84 2.61 10 7

1.17 10 9

0.81 10 14 0.27 10 20 1.09 10 25 0.20 10 51 0.17 10 63 3.30 0.15 0.15 10 65 0.13 1.75 0.15 11 6

2.51 11 7

3.29 11 10 0.14 0.04 11 11 0.45 11 12 2.55 11 19 0.21 0.23 11 20 0.51 0.15 11 26 1.36 11 64 8.42 11 65 0.51 15 2

TEA 0

P 3TWD 5 107 2 VOL 143 P 3 TWD 5 75 P 3 TWD 14 70 P 3 TWD 16 182 1 DNT 73 P 1 SCI 0

P 4TWD 0 66 P 4 TWD 37 61 P 4 TWD 64 62 P 4 TWD 40 0

P 4TWD 0 78 2

VOL 98 2

VOL 22 2

TEA 133 2 VOL 0

P 3TWD 4 54 P 3 TWD 5 109 2 VOL 169 1 DNT 20 2

TEA 87 P 3 TWD 6 41 P 3 TWD 5 38 P 3 TWD 4 58 2

VOL 155 1 BLG 201 2 TEA 77 2

VOL 95 2

VOL 68 P 3 TWD 6 204 2 TEA 149 2 VOL 45 2

VOL 88 P 3 TWD 9 121 P 3 TWD 10 122 P 3 TWD 7 28 2

TEA 21 2

TEA 16 2

TEA 7

2 TEA 123 2 VOL 102 P 3 TWD 9 47 P 3 TWD 9 99 P 3 TWD 4 24 2

TEA 22 2

PID 25 2

MAI 25 2

TWD 52 21 2

TWD 58 17 2

TEA 90 P 3 TWD 10 21 2

VOL 23 2

TEA 92 2

VOL 76 P 3 TWD 4 167 1 DNT 87 2

SAI 83 2

TWD 42 64 2

TWD 45 173 1 DNT 61 2

SAI 21 2

TEA 26 2

TEA 20 2

VOL 82 2

VOL 139 2 VOL 17 2

TEA 73 2

SAI 76 2

TWD 51 122 2 VOL 57 2

VOL 23 2

TEA 186 1 DNT 83 2

VOL UTE 009 008 009 008 010 015 UTS UTS UTS UTS UTS UTS 010 010 UTE 008 010 011 010 010 UTE 011 011 011 001 UTS UTE 014 014 010 UTE 014 006 007 008 008 UTE UTE UTE UTE 009 010 009 011 UTE UTE UTE UTE UTE UTE 009 011 UTE 009 011 015 015 015 015 015 015 UTE UTE UTS 015 009 UTE 015 015 009 008 UTE 010 010

-0.26

+0.55

+0.60

+0.51

+0.70

+0.75

+0.81

-0.01

-0.01

-0.01

-0.01

-0.01

-0.01

-1.71

-2.67

-0.21

-0.70

-0.21

-0.68

+5.40

+0.35

-0.21

-0.83

-0.76

-0.83

-10.46

+0.07

-0.26

+0.80

+1.15

-0.78

-0.20

+0.11

+15.59

+0.82

+0.71

+0.63

-0.21

-0.20

-0.28

-0.20

-0.73

+0.40

+0.60

-0.54

-0.21

-0.18

-0.18

-0.18

-0.18

-0.26

-0.62

+15.40

-0.22

+0.55

-0.83

-0.61

+1.70

+1.70

+1.78

-0.72

+1.78

-0. 18

-0.24

-15.00

+11.63

-0.53

-0.15

-11.73

-11.73

+0.41

+5.97

-0.21

-0.52

-1.24 TO+236. 6 TO+24 6.9 TO+257.1 TO+267.4 TO+2 72.6 TO-2.36 UTE UTE 009 009 008 008 009 009 008 008 010 010 015 015 UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS 010 010 010 010 UTE UTE 008 008 010 010 011 011 010 010 010 010 UTE UTE 011 011 011 011 011 011 001 001 UTE UTS UTE UTE 014 014 014 014 010 010 UTE UTE 014 014 006 006 007 007 008 008 008 008 UTE UTE UTE UTE UTE UTE UTE UTE 009 009 010 010 009 009 011 011 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 009 009 011 011 UTE UTE 009 009 011 011 015 015 015 015 015 015 015 015 015 015 015 015 UTE UTE UTE UTE UTS UTS 015 015 009 009 UTE UTE 015 015 015 015 009 009 008 008 UTE UTE 010 010 010 010 WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR CL CL CL WAR WAR 2013 INLET 4019 INLET 4020 OUTLET 4020 OUTLET 4020 OUTLET 4020 OUTLET 4020 OUTLET 4020 OUTLET 4020 OUTLET 4020 OUTLET 4020 OUTLET 4020 OUTLET 4020 OUTLET 4019 INLET 4019 INLET 2013 INLET 4019 INLET 4019 INLET 4020 OUTLET 4019 INLET 4019 INLET 2013 INLET 4020 OUTLET 4020 OUTLET 4020 OUTLET 4020 OUTLET 4026 INLET 2013 INLET 4019 INLET 4019 INLET 4019 INLET 2013 INLET 4019 INLET 4019 INLET 4020 OUTLET 4020 OUTLET 4020 OUTLET 2013 INLET 2013 INLET 2013 INLET 2013 INLET 4019 INLET 4019 INLET 4020 OUTLET 4019 INLET 2016 INLET 2029 INLET 2013 INLET 2013 INLET 2013 INLET 2013 INLET 4019 INLET 4019 INLET 2013 INLET 4019 INLET 4020 OUTLET 4020 OUTLET 4020 OUTLET 4020 OUTLET 4039 INLET 4039 INLET 4039 INLET 2016 INLET 2016 INLET 4019 INLET 4019 INLET 4019 INLET 2016 INLET 4019 INLET 4019 INLET 4019 INLET 4019 INLET 2016 INLET 4020 OUTLET 4020 OUTLET 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460SI 4 60HR 460SI 460SI 460SI 4 60HR 460SI 460SI 460SI 460SI 460SI 460HR 4 60HR 460HR 460HR 460SI 460SI 460SI 460SI 4 60HR 4 60HR 4 60HR 460HR 460HR 460HR 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 4 60HR 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460HR 460SI 460SI

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:32:38 Component: S/G B Page 3 of 20 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS 11 67 0.17 0.18 3.67 12 1

0.17 12 2

0.25 12 6

1.10 12 21 1.16 12 24 1.29 12 26 2.38 12 28 7.54 12 33 0.23 12 65 0.14 12 67 5.40 4.31 12 68 6.66 0.34 2.28 12 70 1.51 12 71 3.32 0.10 13 4

0.27 13 5

0.59 13 6

0.23 13 8

0.86 13 18 0.39 13 19 0.43 13 20 0.28 13 28 1.72 13 29 1.41 13 35 0.25 13 65 0.23 0.23 0.39 13 68 6.33 3.85 13 70 5.43 13 71 0.38 3.44 13 73 3.02 13 74 0.88 14 26 1.84 14 27 0.68 14 55 0.26 0.27 14 62 2.82 14 69 2.31 5.78 14 70 8.29 10.60 14 72 0.34 2.37 14 73 2.80 14 74 2.79 14 75 0.48 0.21 15 10 1.00 15 18 0.26 15 22 0.80 15 28 1.27 15 39 5.80 5.36 15 52 0.38 2.14 0.99 15 64 0.60 15 67 0.37 15 68 0.32 15 69 0.14 15 71 0.16 15 74 0.24 15 76 0.17 0.12 15 78 0.34 16 1

1.43 16 16 0.21 DEG 94 135 179 42 97 15 17 23 23 2

25 57 179 171 181 138 176 173 172 70 37 46 95 18 121 106 135 17 11 148 111 89 81 169 183 172 109 169 178 146 17 21 0

108 183 17 168 185 180 83 156 190 177 131 82 19 26 23 23 182 178 39 35 27 131 85 89 108 98 95 106 116 138 185 85 CHN 2

2 1

2 2

2 2

2 2

1 P3 2

1 1

1 P3 1

1 1

2 2

P3 2

2 P3 2

2 2

2 P3 2

2 2

1 1

1 2

1 1

P3 2

2 P3 P3 1

2 1

1 1

2 1

1 1

2 2

2 2

2 2

1 1

2 2

2 P3 2

2 2

2 2

P1 2

2 1

2 IND VOL VOL DNT VOL VOL TEA TEA TEA TEA DNT TWD VOL DNT DNT DNT TWD DNT DNT DNT VOL VOL TWD VOL TEA TWD VOL VOL TEA TEA TWD VOL VOL VOL DNT DNT DNT VOL DNT DNT TWD TEA TEA TWD TWD DNT TEA DNT DNT DNT VOL DNT DNT DNT VOL VOL TEA VOL TEA TEA DNT DNT MAI TWD PID TWD VOL VOL VOL VOL VOL VOL TWD VOL DNT VOL

%TW LOCATION 014

+3.89 014

+3.49 015

-0.64 014

+1.50 010

-1.15 UTE

-0.22 UTE

-0.27 UTE

-0.24 UTE

-0.21 004

+14.49 4

011

-0.72 010

-1.62 LTS

-15.52 LTS

-14.58 LTS

-15.14 9

009

-0.72 015

-0.58 015

-0.76 015

-0.74 012

+0.85 010

-1.82 11 010

-0.57 009

+11.33 TO+21.51 UTE

-0.21 7

007

-0.68 007

-0.59 007

-0.79 UTE

-0.23 UTE

-0.21 5

011

-0.74 010

-9.29 010

-13.53 010

-15.18 LTS

-15.48 LTS

-14.70 LTS

-14.68 010

-2.54 015

-0.69 015

-0.63 12 010

+0.29 UTE

-0.19 UTE

-0.16 7

011

-0.71 4

011

-0.74 001

-13.64 UTE

-0.21 LTS

-14.79 LTS

-15.26 010

-0.46 010

-1.55 015

-0.48 015

-0.58 015

-0.62 010

+0.00 015

-3.88 UTE

-0.20 012

+9.57 UTE

-0.18 UTE

-0.23 009

+5.42 006

+17.69 UTE

-2.81 100 UTE

-2.81 UTE

-2.81 13 009

+0.71 009

+9.82 TO+27.55 010

-9.21 TO-16.76 010

-5.84 TO-18.25 010

-1.42 010

-1.48 015

+0.89 3

015

+0.89 010

+0.31 015

+0.99 UTE

-2.68 EXT EXT 0 14 014 014 014 015 015 014 014 010 010 UTE UTE UTE UTE UTE UTE UTE UTE 004 004 011 011 010 010 LTS LTS LTS LTS LTS LTS 009 009 015 015 015 015 015 015 012 012 010 010 010 010 009 009 UTE UTE 007 007 007 007 007 007 UTE UTE UTE UTE 011 011 010 010 010 010 010 010 LTS LTS LTS LTS LTS LTS 010 010 015 015 015 015 010 010 UTE UTE UTE UTE 011 011 011 011 001 001 UTE UTE LTS LTS LTS LTS 010 010 010 010 015 015 015 015 015 015 010 010 015 015 UTE UTE 012 012 UTE UTE UTE UTE 009 009 006 006 UTE UTS UTE UTS UTE UTS 009 009 009 009 010 010 010 010 010 010 010 010 015 015 015 015 010 010 015 015 UTE UTE UTIL 1 UTIL 2 WAR WAR WAR WAR WAR WAR WAR WAR TR WAR CAL #

4020 4020 4020 4022 4026 2016 2016 2016 2016 4022 4022 4020 4020 4020 4020 4020 4020 4020 4029 4039 4022 4022 4022 2016 4022 4022 4022 2016 2016 4022 4020 4020 4020 4020 4020 4020 4020 4020 4020 4039 2016 2016 4023 4039 4023 2068 4023 4023 4023 4023 4023 4039 4020 4020 4039 2016 4022 2016 2016 4022 4022 2067 2067 2121 4023 4023 4023 4023 4023 4023 4023 4023 4043 4041 2030 LEG OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET OUTLET INLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET PROBE 460SI 460SI 460SI 460SI 460SI 460HR 4 60HR 460HR 460HR 460SI 460SI 460SI 460SI 460SI 460SI 4 60SI 4 60SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460HR 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 4 60HR 4 60HR 460SI 460SI 460SI 4 60HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 4 60HR 460SI 4 60HR 460HR 460SI 460SI 4 60HR 4 60HR 460HR 460SI 460SI 460SI 460SI 460SI 4 60SI 460SI 460SI 460SI 460SI 460HR

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:32:38 Component: SIG B Page 4 of 20 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS 0.20 0.08 16 21 0.09 16 42 0.06 16 50 1.01 16 66 0.38 0.26 0.07 0.07 16 72 0.27 16 81 0.98 17 11 1.06 17 12 1.18 17 33 1.04 17 53 0.22 17 72 0.59 17 74 0.66 0.25 17 75 0.62 17 77 0.24 18 2

0.65 18 4

0.25 18 13 2.18 18 25 0.70 18 33 1.56 18 44 1.55 18 66 0.31 18 71 0.69 18 77 0.68 18 79 0.36 0.20 18 81 0.42 19 5

0.67 19 11 0.34 19 13 1.14 19 14 1.15 19 16 0.24 19 18 0.76 19 19 0.27 19 55 0.55 19 67 0.62 19 71 0.31 19 78 0.42 19 79 0.57 0.21 19 80 0.22 19 82 0.97 19 86 0.42 20 16 0.28 20 17 1.92 20 28 1.55 20 73 0.84 20 75 0.35 20 77 0.30 20 78 0.35 0.61 20 79 0.44 20 80 0.15 20 81 0.40 21 2

0.08 21 6

0.15 21 15 0.46 21 30 1.66 21 35 2.25 21 72 0.73 21 77 0.34 21 78 0.84 21 84 0.68 21 85 0.37 21 88 0.09 0.09 0.11 0.11 22 18 1.09 22 20 0.11 DEG CHN 92 2

56 2

76 2

63 2

11 2

63 P 3 44 P 3 81 2

81 2

90 2

125 1 15 2

20 2

18 2

0 P 3 99 2

85 P 3 125 2 84 P 3 114 2 67 P 3 86 2

23 2

22 2

31 2

20 2

62 2

59 P 3 11 2

104 2 90 2

106 2 144 P 3 43 2

17 2

20 2

112 2 15 2

155 P 3 0

P 3 0

P 3 101 2 90 P 3 78 P 3 115 2 110 2 113 P 3 0

P 3 98 2

29 2

17 2

100 P 3 94 P 3 91 2

68 2

57 P 3 69 P 3 77 2

125 P 3 78 2

39 2

141 P 3 19 2

21 2

54 P 3 50 P 3 128 P 3 81 P 3 110 2 96 2

96 2

66 2

66 2

27 2

48 2

IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE PID VOL VOL VOL TEA TWD 9 TWD 6 SAI TWD 17 VOL VOL TEA TEA TEA TWD 6 VOL TWD 15 VOL TWD 14 VOL TWD 12 VOL TEA TEA TEA TEA VOL TWD 15 TEA VOL VOL VOL TWD 12 VOL TEA TEA VOL TEA TWD 5 TWD 13 TWD 14 VOL TWD 10 TWD 13 VOL VOL TWD 20 TWD 12 VOL TEA TEA TWD 18 TWD 8 VOL VOL TWD 14 TWD 10 VOL TWD 9 VOL VOL TWD 8 TEA TEA TWD 16 TWD 8 TWD 9 TWD 15 VOL SAI TWD 27 SAI TWD 61 TEA VOL UTE 015 013 015 UTE 009 011 011 011 010 015 UTE UTE UTE 011 010 009 010 008 009 014 009 UTE UTE UTE UTE 014 008 UTE 010 010 009 009 007 UTE UTE UTS UTE 011 011 014 013 008 008 010 010 010 015 011 UTE UTE 008 008 008 008 009 008 012 009 014 006 007 UTE UTE 011 011 009 008 009 015 015 015 015 UTE 008

-2.68 UTE UTE

-13.35 015 015

-9.65 013 013

-11.79 015 015

-0.12 UTE UTE

+0.76 009 009

-0.82 011 011

-8.60 011 011

-8.60 011 011

-7.28 TO-16.00 010 010

-2.62 015 015

-0.16 UTE UTE

-0.16 UTE UTE

-0.15 UTE UTE

-0.78 011 011

-20.11 TO-11.48 010 010

+0.63 009 009

-8.78 TO-18.79 010 010

-0.77 008 008

+0.71 009 009

+0.84 014 014

+16.73 009 009

-0.15 UTE UTE

-0.17 UTE UTE

-0.17 UTE UTE

-0.11 UTE UTE

-11.61 014 014

+0.77 008 008

-0.25 UTE UTE

+0.15 010 010

-11.86 TO-16.48 010 010

-0.73 009 009

+0.53 009 009

-0.82 007 007

-0.11 UTE UTE

-0.12 UTE UTE

+13.31 UTE UTS

-0.15 UTE UTE

-0.79 011 011

-0.76 011 011

+0.55 014 014

+0.87 013 013

-0.79 008 008

-0.70 008 008

-13.79 TO-18.91 010 010

-16.00 010 010

+0.57 010 010

+0.78 015 015

-7.16 011 011

-0.17 UTE UTE

-0.18 UTE UTE

+0.68 008 008

+0.64 008 008

-0.65 008 008

-0.70 008 008

+0.70 009 009

+0.65 008 008

+1.36 012 012

+0.72 009 009

+13.65 014 014

+5.31 006 006

-0.72 007 007

-0.14 UTE UTE

-0.16 UTE UTE

-0.79 011 011

-0.85 011 011

+0.73 009 009

-0.71 008 008

+0.63 009 009

-1.18 015 015

-1.18 015 015

-2.03 015 015

-2.03 015 015

-0.11 UTE UTE

+1.63 008 008 WAR WAR WAR WAR WAR WAR WAR WAR 2037 4022 4022 4023 2072 4023 4023 4023 4023 4023 4039 2019 2019 2019 4023 4023 4023 4023 4023 4023 4022 4022 2019 2019 2019 2071 4023 4023 2071 4023 4023 4023 4022 4022 2019 2019 4041 2019 4022 4023 4023 4023 4023 4023 4023 4023 4023 4029 4022 2019 2029 4023 4023 4023 4023 4023 4023 4023 4023 4022 4022 4022 2019 2019 4023 4023 4023 4023 4023 4023 4023 4023 4023 2022 4022 INLET INLET INLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET 460HR 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460SI 4 60HR 4 60HR 4 60HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460HR 460HR 460HR 460SI 460SI 4 60HR 460SI 460SI 460SI 460SI 460SI 460HR 460HR 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 4 60HR 460SI WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:32:38 Component: S/G B Page 5 of 20 Component: S/G B Page 5 of 20 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW 22 22 22 23 23 24 24 24 24 25 25 25 25 26 26 26 26 26 26 26 26 27 27 27 27 27 27 27 27 28 29 29 29 29 29 29 29 29 30 30 30 30 30 30 30 31 31 31 31 31 31 31 32 32 32 32 32 33 33 33 33 33 TUBE VOLTS 70 0.68 90 1.10 0.44 93 2.44 48 0.08 93 0.43 18 0.13 0.07 0.13 0.10 37 0.18 39 1.27 74 0.13 3

0.59 4

0.34 42 1.46 69 0.13 5

0.25 15 0.25 17 0.11 22 10.07 56 0.36 85 1.26 1.26 1.15 87 0.12 0.15 98 0.15 1

2.02 28 0.20 40 0.52 59 2.50 78 0.35 85 3.05 90 7.67 100 0.52 43 0.12 2

0.51 16.63 11 0.83 39 0.25 72 2.15 76 0.31 82 0.15 83 0.53 102 1.97 1.91 1.41 4

0.45 0.82 6

0.65 21 0.36 38 0.19 51 0.26 103 0.39 104 0.29 1

13.74 6

0.46 0.13 8

0.38 26 0.09 52 0.20 0.20 76 0.55 104 0.14 4

0.22 5

0.93 15 0.40 62 0.16 86 0.13 1

4.68 2

0.70 4

0.71 6

0.67 30 0.44 DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 66 98 142 177 52 85 55 38 55 49 79 23 32 140 156 26 39 70 55 65 183 34 22 22 27 63 66 47 182 79 21 17 65 27 172 31 77 135 178 16 152 162 92 140 75 156 144 134 42 144 106 125 49 42 148 104 173 85 43 87 77 65 65 37 66 44 83 82 71 35 182 143 109 89 80 P=3 P 3 2

1 2

2 2

2 2

2 2

2 2

P 3 P3 2

2 2

2 2

1 2

2 2

2 2

2 2

1 2

2 2

P 3 2

1 2

2 P 3 1

2 2

1 2

P 3 P 3 1

1 1

P 3 P 3 P3 P 3 2

2 2

2 1

2 2

P 3 2

2 2

P 3 2

2 P 3 P 3 2

2 1

P 3 P 3 P 3 2

TWD 15 TWD 22 VOL DNT VOL VOL VOL VOL TWD 61 TWD 69 VOL TEA VOL TWD 11 TWD 6 TEA VOL VOL VOL VOL DNT VOL MAI TWD 65 PID VOL VOL VOL DNT VOL TEA TEA TWD 8 TEA DNT VOL VOL TWD 9 DNT TEA VOL DNT VOL TWD 3 TWD 12 VOL VOL VOL TWD 8 TWD 14 TWD 12 TWD 7 VOL VOL VOL VOL DNT VOL VOL TWD 7 VOL VOL TWD 49 TWD 12 VOL VOL TWD 16 TWD 7 VOL VOL DNT TWD 10 TWD 10 TWD 10 VOL 011 009 009 015 012 006 007 007 007 007 014 UTE 015 009 009 UTE 004 008 001 009 010 013 UTE UTE UTE LTS 013 012 015 006 UTE UTE 004 UTE 011 010 005 011 010 UTE 014 001 013 011 011 008 008 008 010 008 008 007 003 004 008 008 010 010 010 009 009 014 014 011 014 005 009 007 013 001 015 014 010 008 013

-0.81

+0.71

-0.78

-0.78

-12. 65

+1.60

-16.13

-16.65

-16.13

-16.65

+1.05

-0.17

-15.13

+0.65

+0.64

-0.22

+9.18

-0.72

+1.72

+8.35

+8.21

+0.74

-3. 67

-3.67

-3.67

+19.40

+1.19

+1.54

+0.93

-7.51

-0. 19

-0.12

-0.78

-0.20

+15.34

+0.79

+10. 24

+0.44

+0.35

-0.22

-0.13

-5.59

+6.93

-0.79

-0.75

+7.12

+6.44

+5.40

-0.76

+0.64

-0.48

-0.74

+5.17

-0.93

-0.37

-0.54

+0.27

+14.76

-2.02

+0.63

-1.44

-15.49

-15.49

-0.73

+1.34

+1.84

+0.68

-0.84

+0. 00

-4.22

+0.71

+0.28

-0.60

-0.41

-0.07 011 009 009 015 012 006 007 007 007 007 014 UTE 015 009 009 UTE 004 008 001 009 010 013 UTE UTE UTE LTS 013 012 015 006 UTE UTE 004 UTE 011 010 005 011 010 UTE 014 001 013 011 011 008 008 008 010 008 008 007 003 004 008 008 010 010 010 009 009 014 014 011 014 005 009 007 013 001 015 014 010 008 013 011 009 009 015 012 006 007 007 007 007 014 UTE 015 009 009 UTE 004 008 001 009 010 013 UTS UTS UTS LTS 013 012 015 006 UTE UTE 004 UTE 011 010 005 011 010 UTE 014 001 013 011 011 008 008 008 010 008 008 007 003 004 008 008 010 010 010 009 009 014 014 011 014 005 009 007 013 001 015 014 010 008 013 WAR WAR WAR WAR WAR WAR 4023 4023 4023 4029 4023 4023 4022 4022 4022 4022 4022 2022 4023 4022 4022 2022 4027 4022 4022 4022 4022 4027 2080 2080 2121 4023 4023 4029 4041 4022 2023 2079 4023 2079 4023 4029 4022 4022 4022 2025 4041 4027 4027 4027 4027 4029 4029 4029 4022 4022 4022 4022 4022 4022 4029 4029 4022 4022 4022 4022 4022 4022 4022 4027 4029 4022 4022 4022 4027 4027 4022 4025 4025 4025 4025 OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET OUTLET INLET INLET INLET OUTLET INLET INLET INLET INLET OUTLET INLET INLET INLET OUTLET OUTLET OUTLET INLET INLET INLET INLET OUTLET INLET OUTLET OUTLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET INLET INLET INLET OUTLET OUTLET INLET INLET INLET INLET INLET 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460HR 460HR 460SI 460SI 460SI 460SI 460SI 460HR 4 60HR 460SI 4 60HR 460SI 460SI 460SI 460SI 460SI 4 60HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:32:38 Component: S/G B Page 6 of 20 Component: S/G B Page 6 of 20 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS 33 39 0.21 0.20 33 81 0.27 0.14 33 106 0.29 33 107 0.31 34 3

0.22 34 6

0.53 0.38 34 20 0.37 34 22 0.18 34 23 0.48 34 44 1.07 34 57 0.13 0.14 0.09 0.04 34 65 2.21 34 66 2.32 34 77 4.60 34 88 0.73 0.73 0.47 34 107 0.19 0.34 35 2

4.10 35 6

0.23 35 59 0.25 0.28 35 62 1.91 35 68 1.84 35 73 0.32 35 77 0.21 0.21 35 108 0.22 36 5

6.82 11.03 36 6

4.63 5.08 36 8

0.47 36 9

0.10 0.22 36 107 0.22 0.22 36 109 0.57 36 110 0.21 36 113 0.82 37 20 0.17 37 25 0.07 37 32 0.10 37 59 4.46 38 5

0.44 0.34 38 6

7.83 8.52 38 8

0.34 38 19 0.10 38 24 0.07 38 34 0.68 0.71 0.53 0.53 0.76 38 115 0.22 39 6

0.67 39 7

0.10 39 10 0.39 0.29 39 56 3.70 39 79 0.35 40 4

1.44 40 5

0.30 0.26 0.19 40 6

0.19 DEG CHN 99 2

101 2 24 P 3 36 2

0 P 3 0

P 3 92 2

142 P 3 57 P 3 96 2

62 2

149 P 3 17 2

24 2

25 2

42 2

76 2

20 2

21 2

182 1 19 2

19 2

33 2

93 2

125 2 185 1 100 P 3 88 2

106 2 16 2

15 2

46 P 3 64 2

64 2

141 2 169 1 184 1 164 1 168 1 0

P 3 87 2

101 2 97 2

72 2

0 P 3 84 2

155 P 3 38 2

50 2

56 2

182 1 131 2 148 2 179 1 181 1 128 2 34 2

71 2

23 2

23 2

20 2

20 2

29 2

62 2

60 P 3 21 2

128 2 107 2 174 1 69 2

54 P 3 140 2 152 2 101 2 71 2

IND %TW LOCATION EXT SAI 012

-6.00 012 TWD 33 012

-6.00 012 TWD 6 011

-0.74 011 VOL 012

-9.44 012 TWD 9 009

+0.61 009 TWD 9 008

-0.62 008 VOL 010

+2.68 010 TWD 8 009

+0.79 009 TWD 10 008

-0.35 008 VOL 012

+0.91 012 VOL 011

+4.81 011 TWD 7 007

-0.69 007 TEA UTE

-0.11 UTE VOL 008

+16.19 008 VOL 008

+17.44 008 TWD 78 008

+16.19 008 TWD 31 008

+17.44 008 TEA UTE

-0.15 UTE TEA UTE

-0.18 UTE DNT LTS

+16.67 LTS SAI UTE

-3.52 UTE TWD 44 UTE

-3.52 UTE PID UTE

-3.52 UTE VOL 008

+0.62 008 VOL 008

-0.36 008 DNT 010

+0.00 010 TWD 6 008

-0.39 008 VOL UTE

-2.00 UTE PID UTE

-2.00 UTE TEA UTE

-0.14 UTE TEA UTE

-0.14 UTE TWD 7 013

-0.16 013 SAI UTS

-3.74 UTS TWD 87 UTS

-3.74 UTS VOL 008

+0.50 008 DNT LTE

+15.77 LTS DNT 010

+0.01 010 DNT LTE

+16.73 LTS DNT UTS

+13.46 UTE TWD 13 008

-0.55 008 VOL 008

-0.59 008 TWD 0 008

-0.59 008 VOL UTE

-2.05 UTE PID UTE

-2.05 UTE TWD 13 009

+0.77 009 VOL 014

+1.10 014 TWD 13 008

+0.47 008 VOL LTS

+13.08 LTS VOL 011

-5.34 011 VOL 010

+1.54 010 DNT 006

+2.73 006 VOL 009

+0.62 009 VOL 008

+0.66 008 DNT UTS

+12.20 UTS DNT LTE

+15.83 LTE VOL 008

-0.65 008 VOL 011

+5.04 011 VOL 011

-5.44 011 MAI UTE

-3.34 UTE TWD 65 UTE

-3.34 UTE MAI UTE

-3.34 UTE TWD 56 UTE

-3.34 UTE PID UTE

-3.34 UTE VOL 008

+0.11 008 TWD 8 010

+0.60 010 VOL 014

-13.80 014 VOL 008

-0.84 008 VOL 008

+0.55 008 DNT 008

+15.92 008 VOL 006

+11.66 006 TWD 17 009

+0.69 009 VOL 010

+0.13 010 VOL 010

+0.64 010 VOL 010

+2.91 010 VOL 010

+0.36 010 EXT UTIL 1 UTIL 2 012 012 011 WAR 012 009 WAR 008 WAR 010 009 WAR 008 WAR 012 011 007 WAR UTE 008 008 008 008 UTE UTE LTS UTS TR UTS UTS 008 008 010 008 WAR UTE UTE UTE UTE 013 WAR UTS UTS 008 LTE 010 LTE UTS 008 WAR 008 008 UTE UTE 009 WAR 014 008 WAR LTS 011 010 006 009 008 UTS LTE 008 011 011 UTS TR UTS UTS TR UTS UTS 008 010 WAR 014 008 008 008 006 009 WAR 010 010 010 010 CAL #

4025 4025 4027 4027 4029 4029 4025 4025 4041 4025 4041 4025 2030 4027 4027 4027 4027 2090 2089 4027 2121 2121 2123 4029 4029 4041 4041 2089 2121 2090 2090 4027 4029 4029 4029 4026 4041 4026 4026 4041 4041 4041 2089 2121 4029 4029 4039 4012 4012 4012 4027 4012 4012 4012 4012 4012 4012 4012 2032 2032 2032 2032 2122 4043 4012 4012 4012 4012 4026 4027 4012 4012 4012 4012 4012 LEG INLET INLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET INLET INLET OUTLET INLET INLET INLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET INLET INLET INLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET INLET INLET INLET INLET PROBE 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460HR 460HR 460SI 4 6OHR 460HR 460HR 460SI 460SI 460SI 460SI 460HR 460HR 460HR 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 4 60HR 4 60HR 4 60HR 4 60HR 4 60HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:32:38 Component: S/G B Page 7 of 20 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS DEG 0.66 40 8

0.32 40 80 0.61 40 110 4.99 3.87 3.65 2.81 40 117 0.08 41 4

0.34 41 5

0.25 0.33 41 55 0.29 41 62 0.10 41 113 0.46 42 3

0.26 42 4

0.36 0.34 0.44 42 5

0.25 0.37 42 14 0.19 42 26 0.25 0.25 42 48 0.17 42 112 0.53 42 114 0.10 42 117 0.16 43 6

0.33 43 7

0.76 44 1

1.01 1.01 1.01 44 3

0.31 0.51 0.50 44 4

0.88 44 100 3.21 44 106 0.20 0.19 45 1

0.49 0.20 45 5

0.55 45 62 0.12 45 119 0.56 46 4

0.83 46 14 0.93 46 76 0.08 46 83 2.62 4.43 0.17 0.17 46 91 0.24 0.20 46 95 0.23 46 99 0.49 47 3

1.44 47 4

0.58 47 8

0.06 47 46 0.30 47 75 0.09 0.11 47 85 0.08 47 103 0.21 47 114 0.30 47 122 0.26 48 3

0.53 48 44 0.23 48 61 4.94 49 1

7.62 49 3

0.40 0.40 0.41 49 76 0.23 49 82 0.13 49 113 0.28 61 148 88 174 160 167 153 48 121 103 99 81 72 40 131 0

111 0

0 0

35 70 70 55 13 56 135 129 0

28 28 27 120 76 78 0

189 99 120 0

67 106 60 140 71 14 51 330 3

28 28 122 121 91 83 22 106 56 138 56 54 79 136 70 131 126 0

166 175 26 26 32 33 63 109 CI-P 2

2 1

1 1

1 2

2 2

2 2

2 P

P P

2 P

P P

2 2

2 2

2 2

2 2

P 2

2 2

P 2

2 P

1 2

2 P

2 P

2 P

P 2

2 1

1 2

2 2

2 2

2 2

P 2

P 2

2 2

2 2

2 P

P 1

1 2

2 2

2 2

2

[N IND 3 TWD VOL VOL DNT DNT DNT DNT VOL VOL VOL VOL VOL VOL 3 TWD 3 TWD 3 TWD VOL 3 TWD 3 TWD 3 TWD VOL VOL TWD VOL TEA VOL VOL VOL 3 TWD SAI TWD PID 3 TWD SVI TWD 3 TWD DNT VOL PID 3 TWD VOL 3 TWD VOL 3 TWD 3 TWD TEA VOL DNT DNT SAI TWD VOL PID VOL VOL TEA 3 TWD VOL 1 VOL VOL VOL VOL VOL VOL VOL 3 TWD 3 TWD DNT DNT SAI TWD PID VOL VOL VOL

%TW LOCATION 8

009

+0.69 008

-0.69 015

+8.98 LTS

-21.99 LTS

-7.87 LTS

-0.87 LTS

+13.28 UTS

-19.90 012

-0.30 010

+0.46 010

-10.10 TO-15.04 004

-17.00 015

+18.95 8

008

+0.61 5

009

+0.65 7

009

+0.69 009

-0.60 8

010

+0.41 5

009

+0.68 7

010

+0.57 006

-3.49 UTE

-5.46 31 UTE

-5.46 006

-17.18 UTE

-0.28 012

-12.12 008

+0.35 008

+0.62 14 008

+0.74 UTE

-3.34 89 UTE

-3.34 UTE

-3.34 6

009

+0.65 014

+0.99 19 014

+0.99 14 014

+0.80 001

+6.01 UTE

-3.15 UTE

-3.15 8

014

-0.57 014

+1.16 10 009

+0.65 009

+17.33 10 008

-0.58 21 010

+0.74 UTE

-0.25 008

-9.60 014

+15.22 014

+3.49 014

+15.22 82 014

+15.22 UTE

-3.15 UTE

-3.15 014

-0.48 011

-0.72 UTE

-0.25 16 010

+0.65 014

+5.57 014

+0.48 012

+8.67 009

-12.35 015

-12.75 012

+0.43 UTS

+13.50 015

+18.97 15 009

+0.63 10 014

+0.51 008

+16.48 010

-0.08 UTE

-1.14 78 UTE

-1.14 UTE

-1.14 014

+0.26 LTS

+19.13 011

+0.67 EXT 009 008 015 LTE LTE LTE LTE UTS 012 010 010 004 015 008 009 009 009 010 009 010 006 UTE UTE 006 UTE 012 008 008 008 UTE UTE UTE 009 014 014 014 001 UTE UTE 014 014 009 009 008 010 UTE 008 014 014 014 014 UTE UTE 014 011 UTE 010 014 014 012 009 015 012 UTS 015 009 014 008 010 UTE UTE UTE 014 LTS 011 EXT UTIL 1 UTIL 2 009 WAR 008 015 LTS LTS LTS LTS UTS 012 010 010 004 015 008 WAR 009 WAR 009 WAR 009 010 WAR 009 WAR 010 WAR 006 UTE UTE 006 UTE 012 008 008 008 WAR UTS UTS UTS 009 WAR 014 014 014 WAR 001 UTE UTE 014 WAR 014 009 WAR 009 008 WAR 010 WAR UTE 008 014 014 014 014 UTE UTE 014 011 UTE 010 WAR 014 014 012 009 015 012 UTS 015 009 WAR 014 WAR 008 010 UTE UTE UTE 014 LTS 011 CAL #

4012 4012 4029 4029 4029 4029 4029 4039 4031 4007 4007 4007 4031 4035 4007 4007 4007 4007 4007 4007 4007 4007 4007 4011 2092 4035 4035 4007 4007 2056 2056 2122 4007 4007 4007 4007 4035 2110 2123 4007 4007 4007 4033 4035 4009 2055 4031 4031 4031 4031 4031 2099 2123 4033 4043 2052 4009 4009 4011 4031 4031 4031 4035 4035 4037 4009 4011 4014 4009 2046 2046 2059 4031 4031 4035 LEG INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET OUTLET OUTLET OUTLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET OUTLET OUTLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET OUTLET OUTLET OUTLET INLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET PROBE 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460HR 460HR 460HR 460SI 460SI 460SI 460SI 460SI 460HR 460HR 460SI 460SI 460SI 460SI 460SI 460SI 4 60HR 460SI 460SI 460SI 460SI 460SI 4 60HR 4 60HR 460SI 460SI 4 60HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 4 60HR 4 60HR 4 60HR 460SI 460SI 460SI

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:32:38 Component: S/G B Page 8 of 20 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW 49 50 50 50 50 50 50 50 51 51 51 51 51 52 52 52 52 52 52 52 52 52 53 53 53 53 53 53 53 54 54 55 55 55 56 56 56 56 56 56 56 56 57 57 57 57 57 57 57 58 58 58 58 58 59 TUBE 114 3

11 29 62 64 102 107 3

4 6

28 124 26 29 35 75 98 108 113 121 122 1

7 17 21 28 54 71 41 124 45 48 120 9

18 32 39 90 93 110 126 1

2 10 27 93 114 122 3

41 94 124 125 1

VOLTS 0.25 0.47 0.49 0.12 0.06 0.09 0.09 0.29 0.49 1.11

0. 15 0.31 0.37 0.16 2.48 3.97 4.55 1.77 0.21 0.32 0.32 0.40 0.12 0.12 0.12 0.17 0.23 0.22 0.12 0.10 1.25 0.26 2.09 0.33 0.22 0.05 0.06 0.09 0.10 0.10 0.22 0.08 0.23 0.86 0.15
0. 32 0.32 0.67 0.14 0.11 0.10 0.10 0.88 0.88 0.98 8.97 0.11 0.26 6.90 6.56 7.05 4.48 0.15 0.05
0. 11 0.13 0.49 6.04
0. 10 7.86 5.52
0. 11 0.71 0.26 5.98 DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 98 90 131 67 41 64 57 77 28 15 75 102 80 56 183 177 174 184 42 20 20 22 49 44 43 52 63 62 111 57 17 101 22 125 136 62 66 85 50 36 49 66 68 28 43 105 88 80 49 46 58 44 18 18 18 186 76 54 172 180 1

173 61 43 44 76 136 357 127 4

178 39 95 124 168 2

2 P

2 2

2 2

2 2

2 2

P 2

2 1

1 1

1 2

2 2

2 2

2 2

2 2

2 2

2 2

P 2

2 2

2 2

2 2

2 2

2 P

2 2

2 2

P P

2 2

2 2

2 2

1 2

P 1

1 1

1 2

2 2

2 P

1 2

1 1

2 P

2 1

VOL TWD 0 3 TWD 14 VOL VOL VOL VOL VOL TEA TEA VOL 3 TWD 9 VOL VOL DNT DNT DNT DNT VOL SAI TWD 58 PID VOL TWD 65 VOL VOL VOL TWD 58 VOL VOL TEA 3 TWD 5 TEA VOL VOL VOL VOL VOL VOL VOL VOL VOL 3 VOL TWD 76 VOL VOL PID 3 TWD 12 1 VOL VOL VOL VOL SAI TWD 49 PID DNT VOL 3 TWD 5 DNT DNT DNT DNT VOL VOL VOL VOL 3 TWD 9 DNT VOL DNT DNT VOL 3 TWD 13 VOL DNT 011 011 009 008 011 012 014 013 UTE UTE 014 009 010 002 LTS 001 UTS 015 013 UTE UTE UTE 015 015 LTS 012 014 014 014 UTS UTE 010 UTE 011 009 014 013 010 UTS 014 014 009 013 013 008 UTE UTE 008 015 010 012 012 UTE UTE UTE UTS 011 009 LTS UTE LTS UTE 011 011 008 011 010 LTS 010 UTE UTS 003 009 009 LTS

+1.54

+1.54

+0. 66

+7.84

+3.51

-12.09

-5.18

+0.35

-0.21

-0.15

+6.64

+0.78

-23.43

+2.57

-13.11

+5.79

+0. 09

+0.82

-8.96

-3.05

-3.05

-3.05

+13. 42

+13.42

+22.13

-15.88

+0.78

+0.78

+0.71

-1.45

-0.12

+0.54

-0.23

+0.56

-0.69

-10. 91

-8. 10

+14.67

-14.63

+18.54

+0.46

+6.13

+1.31

+1.31

+11.48

-1. 91

-1. 91

-0.59

+40. 69

-6.94

-4.36

+11.24

-0.27

-0.27

-0.27

+6.53

+1.37

-0.65

-13.22

-11.56

-13.36

-11.57

+1.09

+13. 28

+16.33

+7.61

+0.47

-12.92

-0.04

-11.64

+9.15

-15.04

-0.70

+0. 65

-13.44 011 011 009 008 011 012 014 013 UTE UTE 014 009 010 002 LTS 001 UTS 015 013 UTE UTE UTE 015 015 LTS 012 014 014 014 UTS UTE 010 UTE 011 009 014 013 010 UTS 014 014 009 013 013 008 UTE UTE 008 015 010 012 012 UTE UTE UTE UTS 011 009 LTS UTE LTS UTE 011 011 008 011 010 LTS 010 UTE UTS 003 009 009 LTS 011 011 009 008 011 012 014 013 UTE UTE 014 009 010 002 LTS 001 UTS 015 013 UTS UTS UTS 015 015 LTS 012 014 014 014 UTS UTE 010 UTE 011 009 014 013 010 UTS 014 014 009 013 013 008 UTE UTE 008 015 010 012 012 UTE UTE UTE UTS 011 009 LTS UTE LTS UTE 011 011 008 011 010 LTS 010 UTE UTS 003 009 009 LTS WAR WAR TR WAR CS WAR CL WAR WAR WAR 4035 4035 4009 4009 4009 4009 4009 4014 2120 2106 4035 4009 4009 4009 4009 4009 4037 4037 4009 2046 2046 2122 4009 4009 4009 4031 4033 4033 4035 4037 2106 4037 2107 4011 4009 4009 4009 4009 4009 4009 4031 4009 4037 4037 4009 2063 2122 4037 4011 4009 4009 4009 2106 2106 2123 4033 4035 4037 4011 4011 4009 4009 4011 4009 4033 4035 4037 4009 4009 4009 4011 4033 4037 4037 4011 INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET OUTLET INLET INLET INLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET INLET INLET OUTLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET OUTLET 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 4 60HR 4 60HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460HR 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 4 60HR 460SI 4 60HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 4 60HR 4 60HR 460SI 460SI 460SI 460SI 460SI 4 60HR 460HR 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:32:38 Component: S/G B Page 9 of 20 Component: S/G B Page 9 of 20 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS 59 5

5.94 59 8

0.25 59 39 0.15 59 96 0.28 59 101 3.76 59 118 0.24 0.35 59 120 0.22 59 121 0.34 1.38 59 122 0.62 0.69 60 115 6.67 60 118 5.14 60 124 0.35 60 126 0.38 61 1

5.86 0.12 0.13 0.18 0.18 0.13 0.11 61 2

0.20 61 28 0.28 61 58 0.32 61 85 4.36 0.20 61 103 6.40 61 108 0.08 61 110 6.86 61 111 0.09 61 121 1.19 61 122 0.41 0.96 1.39 61 124 0.35 61 126 0.38 0.38 62 112 8.36 62 115 0.29 63 59 0.45 63 66 0.37 63 113 5.78 63 114 6.73 63 128 0.32 0.32 0.46 64 35 0.11 0.12 64 124 0.82 65 60 0.98 65 69 0.17 65 76 0.10 65 99 0.11 65 126 6.43 0.75 65 127 0.66 0.63 65 128 0.42 65 129 0.34 66 41 1.16 66 57 0.15 66 81 0.18 0.16 66 108 1.89 6.53 2.40 2.79 3.26 3.45 4.25 5.98 6.50 5.70 DEG CHN IND %T) 181 1 DNT 0

P 3 TWD 11 56 2

VOL 67 2

VOL 191 1 DNT 137 2 VOL 85 P 3TWD 7 78 2

VOL 97 2

VOL 85 P 3 TWD 13 120 P 3 TWD 11 149 P 3 TWD 12 172 1 DNT 173 1 DNT 123 2 VOL 93 2

VOL 180 1 DNT 94 2

SAI 90 2

TWD 32 100 2 MAI 91 2

TWD 31 79 2

TWD 44 107 2 PID 72 2

VOL 105 2 VOL 134 2 VOL 184 1 DNT 86 2

VOL 350 1 DNT 69 2

VOL 175 1 DNT 88 2

VOL 143 P 3 TWD 12 95 2

VOL 142 P 3 TWD 10 131 P 3 TWD 13 147 2 VOL 45 2

SAI 45 2

TWD 99 169 1 DNT 82 2

VOL 136 P 3 TWD 7 139 P 3 TWD 6 359 1 DNT 0

1 DNT 82 2

VOL 82 2

TWD 73 148 P 3 TWD 9 119 2 VOL 108 2 PID 86 P 3 TWD 15 16 2

TEA 65 2

VOL 55 2

VOL 67 2

VOL 180 1 DNT 88 P 3 TWD 14 63 P 3 TWD 12 70 P 3 TWD 11 108 2 VOL 111 2 VOL 121 1 DNT 46 P 1 VOL 111 2 PID 129 2 VOL 37 P 1 PID 37 P 1 SCI 100 P 1 TWD 0 89 P 1 TWD 29 81 P 1 TWD 37 84 P 1TWD 34 69 P 1 TWD 49 54 P 1 TWD 66 55 P 1 TWD 65 64 P 1 TWD 55

' LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE LTS 009 015 013 001 009 008 010 010 009 009 008 014 014 009 010 001 015 015 015 015 015 015 014 UTE 013 UTS 015 001 014 LTS 014 009 010 009 009 009 011 011 LTS 014 013 014 LTS LTS 014 014 009 UTE UTE 009 UTE 005 009 009 UTS 009 009 008 009 010 LTS 008 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE

+14.79 LTS

-0.64 009

+15.56 015

+0.84 013

+6.31 001

-0.53 009

-0.69 008

-15.29 TO-20.87 010

-12.28 TO-18.43 010

+0.50 009

-0.71 009

-0.59 008

-2.50 014

-2.66 014

-0.78 009

-2.43 TO-15.99 010

+4.72 001

+3.55 TO+4.95 015

+3.55 TO+4.95 015

+5.07 TO+7.26 015

+5.07 TO+7.26 015

+5.07 TO+7.26 015

+5.07 TO+7.26 015

+1.31 014

-7.50 UTE

+0.03 013

-6.06 UTS

+0.81 015

+6.28 001

-13.12 014

-12.71 LTS

+0.86 014

-0.67 009

-7.54 TO-19.85 010

+0.65 009

-0.67 009

-0.64 009

+5.26 011

+5.26 011

-13.16 LTS

+1.43 014

+0.71 013

+0.71 014

-13.23 LTS

-13.09 LTS

+0.94 014

+0.94 014

-0.71 009

-2.98 UTE

-2.98 UTE

-0.62 009

-0.30 UTE

+30.19 005

-19.28 009

+16.67 009

+7.57 UTS

-0.69 009

-0.67 009

-0.68 008

-0.59 009

-1.71 010

-1.49 LTS

+7.05 008

-1.86 UTE

-1.86 UTE

-0.11 UTE

-0.11 UTE

-0.11 TO+80.5 UTE

-0.11 TO+88.9 UTE

-0.11 TO+97.4 UTE

-0.11 TO+105.9 UTE

-0.11 TO+114.4 UTE

-0.11 TO+122.8 UTE

-0.11 TO+131.3 UTE

-0.11 TO+139.8 UTE LTS 009 015 013 001 009 008 010 010 009 009 008 014 014 009 010 001 015 015 015 015 015 015 014 UTE 013 UTS 015 001 014 LTS 014 009 010 009 009 009 011 011 LTS 014 013 014 LTS LTS 014 014 009 UTE UTE 009 UTE 006 009 009 UTS 009 009 008 009 010 LTS 008 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE WAR WAR WAR WAR WAR WAR WAR WAR 4011 4011 4011 4033 4033 4037 4037 4037 4037 4037 4037 4037 4035 4035 4037 4037 4011 903 903 903 903 903 907 4011 4009 4003 4033 4033 4035 4035 4035 4035 4037 4037 4037 4037 4037 4037 4037 4035 4035 4003 4003 4035 4035 4037 4037 4037 2041 2122 4037 2002 4003 4043 4033 4037 4037 4037 4037 4037 4037 4011 4011 2123 2115 2123 2114 2114 2114 2114 2114 2114 2114 2114 2114 OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 4 6OLW 4 6OLW 4 6OLW 4 6OLW 460LW 46OLW 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 4 60HR 4 60HR 460SI 460HR 4 60SI 460SI 460SI 460SI 460SI 460SI 460SI 4 60SI 4 60SI 4 60SI 460SI 4 60HR 4 60HR 4 60HR 4 60HR 4 60HR 460HR 4 60HR 4 60HR 460HR 460HR 4 60HR 4 60HR WAR WAR WAR WAR WAR WAR WAR Cs CL

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:32:38 Component: S/G B Page 10 of 20 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMI ROW TUBE VOLTS 4.41 3.56 3.11 2.49 66 127 0.35 66 128 1.21 66 129 0.43 67 1

7.30 67 69 1.15 0.28 67 86 1.65 67 105 0.23 67 107 0.11 0.10 0.13 0.10 67 122 1.20 67 130 1.97 68 40 0.32 68 84 0.19 0.16 68 86 0.46 68 106 0.77 68 123 0.43 68 130 2.22 68 131 2.09 69 19 5.77 69 25 0.16 69 81 0.38 0.34 0.18 69 131 9.49 70 1

3.81 70 3

0.27 70 111 0.62 70 123 0.18 0.18 70 131 11.60 0.08 71 1

1.81 71 2

3.09 71 3

2.49 71 4

2.52 71 5

0.45 71 6

0.19 0.31 71 68 0.21 71 81 0.22 0.21 71 85 0.45 0.57 0.57 0.15 71 88 8.57 71 131 0.19 0.08 72 3

1.19 72 12 0.23 72 13 0.28 72 14 1.06 72 19 0.30 72 41 0.22 72 58 0.12 72 85 0.89 72 95 0.22 0.19 72 99 0.09 73 1

4.02 73 3

1.65 5.44 1.36 73 6

0.46 73 9

0.67 73 10 0.13 73 14 0.44 DEG CHN IND %TW LOCATION 70 P 1 TWO 48 UTE

-0.11 TO+148.2 70 P 1 TWD 48 UTE

-0.11 TO+156.7 75 P 1 TWD 43 UTE

-0.11 TO+165.2 88 P 1 TWD 0 UTE

-0.11 TO+173.6 127 2 VOL 010

-11.80 TO-19.35 133 P 3 TWD 12 009

-0.65 74 P 3 TWD 8 009

-0.65 176 1 DNT 010

-1.65 100 1 VOL LTS

-17.71 115 2 PID LTS

-17.71 18 2

TEA UTE

-0.17 23 2

TEA UTE

-0.26 86 2

SAI UTS

-0.69 62 2

SAI UTS

-1.09 78 2

TWD 39 UTS

-0.69 64 2

TWD 82 UTS

-1.09 10 2

TEA UTE

-0.21 175 1 DNT 015

-0.19 103 P 1 VOL 014

-0.09 101 2 PID UTE

-1.50 118 2 VOL UTE

-1.50 15 2

TEA UTE

-0.19 20 2

TEA UTE

-0.24 137 P 3 TWD 8 009

-0.76 176 1 DNT 015

-0.42 178 1 DNT 015

-0.10 179 1 DNT 003

+5.00 69 P 1 VOL 004

+6.95 123 2 PID UTE

-2.23 125 2 VOL UTE

-2.23 91 2

VOL UTS

+12.67 174 1 DNT 010

-0.25 20 P 1 DRS UTE

-0.76 122 2 VOL 014

+0.01 124 2 VOL 006

-0.64 88 2

VOL 014

+0.90 88 2

TWD 0 014

+0.90 171 1 DNT 010

-0.00 95 2

VOL 010

+5.58 17 P 1 DRS UTE

-0.82 22 P 1 DRS UTE

-0.77 21 P 1 DRS UTE

-0.76 25 P 1 DRS UTE

-0.83 85 P 3 TWD 11 009

-0.65 76 2

VOL 006

+7.77 125 2 VOL 011

+0.45 62 2

VOL 001

+33.74 122 2 VOL UTE

-1.71 116 2 PID UTE

-1.71 19 4

PID UTE

-3.04 21 2

MAI UTE

-3.04 21 2

TWD 60 UTE

-3.04 28 2

TWD 83 UTE

-3.22 176 1 DNT 002

+11.72 57 2

VOL 015

+0.47 83 2

VOL 015

+0.38 26 P 1 DRS UTE

-0.80 0

P 3 TWD 10 012

+0.50 146 2 VOL 012

+0.37 13 2

TEA UTE

-0.17 156 P 1 VOL 011

+0.56 0

P 3 TWD 9 010

+0.54 91 2

VOL 014

-0.22 22 2

TEA UTE

-0.18 154 2 VOL UTE

-2.32 137 2 PID UTE

-2.32 65 2

VOL 014

+1.08 23 P 1 DRS UTE

-0.80 125 P 3 VOL 015

-10.57 19 P 1 DRS UTE

-0.79 123 P 3 PID 015

-10.57 92 P 3 TWD 11 012

+0.60 42 P 3 TWD 16 013

+0.48 97 2

VOL 011

+5.61 48 P 1 SCI 015

+0.83 EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

=

UTE UTE UTE UTE UTE UTE UTE UTE 010 010 009 009 009 009 010 010 LTS LTS LTS LTS UTE UTE UTE UTE UTS UTS UTS UTS UTS UTS UTS UTS UTE UTE 015 015 013 014 UTE UTE UTE UTE UTE UTE UTE UTE 009 009 015 015 015 015 003 003 004 004 UTE UTE UTE UTE UTS UTS 010 010 UTE UTE 014 014 006 006 014 014 014 014 010 010 010 010 UTE UTE UTE UTE UTE UTE UTE UTE 009 009 006 006 011 011 001 002 UTE UTE UTE UTE UTE UTS UTE UTS UTE UTS UTE UTS 002 002 015 015 015 015 UTE UTE 012 012 012 012 UTE UTE 011 011 010 010 014 014 UTE UTE UTE UTE UTE UTE 014 014 UTE UTE 015 015 UTE UTE 015 015 012 012 013 013 011 011 015 015 WAR WAR TR WAR TR SLV 2114 2114 2114 2114 4037 4037 4037 4016 3001 3007 2115 2114 4033 4033 4033 4033 2115 4037 4011 2123 2114 2114 2123 4035 4037 4037 4011 4011 2123 2114 4033 4037 1010 4016 4033 4035 4035 4037 4037 1010 1010 1010 1011 4016 4016 4016 4003 2123 2124 2123 2117 2117 2117 4033 4037 4037 1011 4011 4011 2035 4011 4011 4003 2117 2118 2123 4033 1010 1007 1007 1011 4016 4016 4016 904 INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET INLET INLET INLET INLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET 460HR 460HR 460HR 4 60HR 460SI 460SI 460SI 460SI 460TS 4 60TS 4 60HR 4 60HR 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460HR 460HR 460HR 4 60HR 460SI 460SI 460SI 460SI 460SI 460HR 460HR 460SI 460SI 400PS 460SI 460SI 460SI 460SI 460SI 460SI 400PS 400PS 400PS 400PS 460SI 460SI 4 60SI 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460SI 460SI 400PS 460SI 460SI 460HR 460SI 460SI 460SI 460HR 460HR 4 60HR 460SI 400PS 400PS 400PS 400PS 460SI 460SI 460SI 4 6OLW SLV SLV SLV SLV WAR CS SLV WAR WAR CS SLV TUB SLV WAR WAR

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:32:38 Component: S/G B Page 11 of 20 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS 0.42 0.23 0.32 0.41 0.49 0.56 0.58 0.62 0.70 0.74 0.64 0.53 0.49 0.45 0.39 0.31 0.23 0.19 0.46 73 29 0.25 73 64 1.08 73 77 1.56 73 103 0.10 73 125 0.18 74 1

2.32 6.41 74 9

3.12 74 25 1.57 1.94 74 30 0.71 0.59 74 63 0.50 74 80 1.80 74 99 6.80 74 124 0.11 74 125 0.64 75 1

6.22 3.56 75 4

4.69 75 13 4.00 75 14 3.22 75 15 2.83 75 21 0.10 5.34 75 29 1.88 1.22 1.80 75 30 2.24 75 37 3.33 3.56 75 40 1.31 75 99 0.15 75 111 0.20 0.34 75 112 0.22 0.22 75 121 0.41 75 123 0.11 76 98 0.18 0.18 77 3

4.53 7.54 77 5

4.81 77 6

4.31 4.44 77 8

2.80 4.80 77 22 5.68 4.18 77 24 2.71 77 25 0.14 4.91 77 26 4.03 77 27 6.38 77 38 7.72 DEG 48 50 49 45 40 38 38 36 32 30 31 35 37 37 36 36 29 24 66 136 16 14 75 137 21 157 15 27 40 49 47 140 21 188 106 11 21 164 21 17 23 23 33 20 118 98 124 34 227 57 47 60 88 69 96 96 153 68 80 76 24 169 20 22 18 178 11 356 22 28 70 26 20 22 68 CHN P 1 P 4 P 4 P 4 P 4 P 4 P 4 P 4 P 4 P 4 P 4 P 4 P 4 P 4 P 4 P 4 P 4 P 4 P 1 P 1 2

2 2

2 P1 1

P1 P 1 P 1 P 1 P 1 P 3 2

1 2

2 P1 1

P1 P 1 P 1 P 1 2

P1 P 3 P 3 P 3 P 1 P 1 P 1 P 1 2

2 2

2 2

P3 2

2 2

P 1 1

P 1 P 1 P 1 1

P 1 1

P1 P 1 2

P 1 P 1 P 1 P 2 IND %T TWD 77 TWD 0 TWD 33 TWD 42 TWD 52 TWD 58 TWD 60 TWD 65 TWD 73 TWD 77 TWD 66 TWD 55 TWD 51 TWD 46 TWD 40 TWD 32 TWD 24 TWD 0 PID VOL TEA TEA VOL VOL DRS DNT DRS PVN PID VOL PID TWD 8 TEA DNT VOL TEA DRS DNT DRS DRS DRS DRS VOL DRS VOL VOL PID DRS PVN PID DRS VOL VOL TWD 48 VOL TWD 89 TWD 8 VOL SAI TWD 51 DRS DNT DRS DRS DRS DNT DRS DNT DRS DRS VOL DRS DRS DRS PID N LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE 015 015 015 015 015 015 015 015 015 015 015 015 015 015 015 015 015 015 015 011 UTE UTE 010 010 UTE LTS UTE 015 015 015 015 006 UTE 014 014 UTE UTE LTS UTE UTE UTE UTE 008 UTE 015 015 015 UTE UTE UTE UTE 012 014 014 014 014 003 014 011 011 UTE LTS UTE UTE UTE LTS UTE LTS UTE UTE 011 UTE UTE UTE UTE

+0.83

+0.83

+0.83

+0.83

+0.83

+0.83

+0.83

+0.83

+0.83

+0.83

+0.83

+0.83

+0.83

+0.83

+0.83

+0.83

+0.83

+0.83

+0.83

+0.57

-0.25

-0.17

-12.19

+0.42

-0.80

-13.32

-0.80

-6.89

-6.89

-7.86

-7.86

+0.69

-0.34

-4. 67

+1.30

-0.32

-0.80

-13.34

-0.69

-0.73

-0.76

-0.76

+13. 03

-0.75

-10.13

-11.69

-11.69

-0.75

-0.42

-0.42

-0.47

-4.12

+1.06

+1.06

+1.12

+1.12

-0.80

+1.30

-8.41

-8.41

-0.71

-13.20

-0.74

-0.94

-0.70

-13.36

-0.69

-13.14

-0.79

-0.79

+7.69

-0.80

-0.83

-0.82

-0.57 TO+293.1 TO+288.0 TO+282.9 TO+2 77.7 TO+272.6 TO+2 67.4 TO+2 62.3 TO+257.1 TO+252.0 TO+246. 9 TO+241. 7 TO+236. 6 TO+231.4 TO+226. 3 TO+221.1 TO+216. 0 TO+210.9 015 015 015 015 015 015 015 015 015 015 015 015 015 015 015 015 015 015 015 011 UTE UTE 010 010 UTE LTS UTE 015 015 015 015 006 UTE 014 014 UTE UTE LTS UTE UTE UTE UTE 008 UTE 015 015 015 UTE UTE UTS UTE 012 014 014 014 014 003 014 011 011 UTE LTS UTE UTE UTE LTS UTE LTS UTE UTE 011 UTE UTE UTE UTS 015 015 015 015 015 015 015 015 015 015 015 015 015 015 015 015 015 015 015 011 UTE UTE 010 010 UTE LTS UTE 015 015 015 015 006 UTE 014 014 UTE UTE LTS UTE UTE UTE UTE 008 UTE 015 015 015 UTE UTS UTE UTS 012 014 014 014 014 003 014 011 011 UTE LTS UTE UTE UTE LTS UTE LTS UTE UTE 011 UTE UTE UTE UTE SLV SLV SLV SLV WAR SLV SLV SLV SLV SLV SLV TUB TUB SLV SLV SLV WAR SLV SLV SLV SLV SLV SLV SLV SLV SLV SLV 904 904 904 904 904 904 904 904 904 904 904 904 904 904 904 904 904 904 908 4011 2002 2118 4033 4035 1010 4018 1007 1007 1013 1006 1011 4003 2120 4033 4037 2120 1010 4018 1005 1005 1005 1005 4016 1006 1006 1006 1011 1006 1006 1013 1006 4033 4033 4033 4037 4037 4037 4037 4033 4033 1005 4018 1005 1005 1005 4016 1005 4016 1005 1005 4016 1005 1005 1005 1013 OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET INLET INLET INLET INLET INLET OUTLET INLET INLET INLET INLET INLET OUTLET INLET INLET INLET INLET INLET OUTLET INLET INLET INLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET INLET INLET INLET OUTLET INLET OUTLET INLET INLET OUTLET INLET INLET INLET INLET 460LW 460LW 46OLW 46OLW 46OLW 46OLW 46OLW 46OLW 46OLW 4 6OLW 46OLW 4 6OLW 46OLW 4 6OLW 460LW 460LW 4 6OLW 460LW 4 6OLW 460SI 4 60HR 4 60HR 4 60SI 460SI 400PS 460SI 40OPS 400PS 400PS 400PS 400PS 460SI 460HR 460SI 460SI 460HR 400PS 460SI 400PS 400PS 400PS 400PS 460SI 400PS 400PS 400PS 400PS 400PS 400PS 400PS 400PS 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 400PS 460SI 400PS 400PS 400PS 4 60SI 400PS 460SI 400PS 400PS 460SI 400PS 400PS 400PS 400PS

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:32:38 Component: S/G B Page 12 of 20 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMi ROW TUBE VOLTS 5.35 77 44 0.36 77 50 0.32 77 66 0.08 78 3

5.56 5.85 78 8

1.47 78 9

4.84 78 10 6.95 3.13 78 11 5.02 2.26 78 12 5.68 2.63 78 13 7.32 3.82 2.69 78 14 6.03 4.42 0.09 78 15 4.79 78 17 4.27 2.54 78 18 5.70 2.93 78 19 5.09 3.88 1.55 78 20 4.93 4.95 78 21 5.13 78 23 1.34 78 24 2.96 1.77 78 34 0.64 78 42 0.45 78 44 0.21 78 111 0.13 79 1

3.16 5.49 79 2

3.01 79 4

3.78 4.03 1.58 79 35 0.08 79 62 2.57 80 7

0.14 80 48 0.26 80 62 2.69 80 63 0.46 80 71 1.54 80 123 0.23 80 130 0.13 81 1

4.52 81 2

0.37 81 18 0.20 0.18 81 29 0.57 81 36 0.75 81 37 0.65 81 44 0.73 81 62 4.21 82 5

5.96 0.12 82 10 0.15 82 13 0.15 82 29 0.74 82 33 0.79 82 47 0.24 82 53 0.18 82 62 2.24 82 63 3.35 82 64 0.15 82 106 0.80 3.86 DEG CHN IND 64 P 2PVN 135 2 VOL 96 2

VOL 51 2

VOL 23 P 1 DRS 21 P 1 DRS 189 1 DNT 350 1 DNT 176 1 DNT 179 1 DNT 347 1 DNT 341 1 DNT 173 1 DNT 21 P 1 DRS 177 1 DNT 177 1 DNT 23 P 1 DRS 350 1 DNT 348 1 DNT 56 2

VOL 344 1 DNT 345 1 DNT 343 1 DNT 354 1 DNT 19 P 1 DRS 350 1 DNT 347 1 DNT 0

1 DNT 355 1 DNT 349 1 DNT 351 1 DNT 26 P 1 DRS 25 P 1 VOL 22 P 3 PID 73 P 3 TWD 0

P 3TWD 43 2

VOL 91 2

VOL 18 P 1 DRS 169 1 DNT 176 1 DNT 18 P 1 PID 14 P 1 SAI 24 P 1 DRS 35 2

VOL 24 2

TEA 105 2 VOL 100 2 VOL 355 1 DNT 170 2 DNT 139 1 VOL 78 2

VOL 0

P 3TWD 22 P 1 DRS 101 2 VOL 92 2

VOL 80 2

TWD 0

P 3TWD 0

P 3TWD 0

P 3TWD 0

P 3TWD 351 1 DNT 171 1 DNT 126 2 VOL 84 2

VOL 68 2

VOL 0

P 3TWD 0

P 3TWD 109 1 VOL 51 2

VOL 153 1 DNT 1

1 DNT 81 2

VOL 29 2

TEA 184 1 DNT

%TW LOCATION UTE

-0.57 003

-0.68 007

-0.75 015

+8.88 UTE

-0.82 UTE

-0.82 LTS

-13.48 LTS

-14.72 LTS

-15.24 LTS

-11.34 LTS

-12.39 LTS

-13.40 LTS

-13.73 UTE

-0.67 LTS

-16.05 LTS

-13.29 UTE

-0.82 LTS

-13.80 LTS

-16.80 009

+11.39 LTS

-13.34 LTS

-13.85 LTS

-12.79 LTS

-13.15 UTE

-0.86 LTS

-16.20 LTS

-13.32 LTS

-12.23 LTS

-16.37 LTS

-12.92 LTS

-12.90 UTE

-0.90 UTE

-0.77 UTE

-0.77 15 004

-0.74 9

004

-0.67 004

+6.25 014

+1.00 UTE

-0.80 LTS

-12.95 LTS

-13.64 015

-9.09 015

-9.09 UTE

-1.03 LTS

+22.36 UTE

-0.31 011

-2.66 014

+10.99 UTS

+16.06 UTS

+16.32 006

-6.01 014

+1.84 4

008

-0.48 UTE

-0.80 012

+0.47 014

-0.82 42 014

-0.82 8

010

-0.76 10 010

-0.74 9

010

-0.73 10 010

-0.75 UTS

+15.66 010

-0.58 010

+5.22 TO+10.72 007

+7.63 003

-18.18 10 010

-0.74 10 010

-0.76 013

-11.00 014

+2.22 UTS

+16.45 UTS

+16.29 001

+1.12 UTE

-0.14 014

-2.82 EXT UTE 003 007 015 UTE UTE LTS LTS LTS LTS LTS LTS LTS UTE LTS LTS UTE LTS LTS 009 LTS LTS LTS LTS UTE LTS LTS LTS LTS LTS LTS UTE UTE UTE 004 004 004 014 UTE LTS LTS 015 015 UTE LTS UTE 011 014 UTE UTE 006 014 008 UTE 012 014 014 010 010 010 010 UTE 010 010 007 003 010 010 013 014 UTS UTE 001 UTE 014 EXT UTIL 1 UTS SLV 003 007 015 UTE SLV UTE SLV LTS LTS LTS LTS LTS LTS LTS UTE SLV LTS LTS UTE SLV LTS LTS 009 LTS LTS LTS LTS UTE SLV LTS LTS LTS LTS LTS LTS UTE SLV UTE SLV UTE 004 WAR 004 WAR 004 014 UTE SLV LTS LTS 015 015 SLV UTE SLV LTS UTE 011 014 UTS UTS 006 014 008 WAR UTE SLV 012 014 014 010 WAR 010 WAR 010 WAR 010 WAR UTS 010 010 007 003 010 WAR 010 WAR 013 014 UTS UTS 001 UTE 014 UTIL 2 CAL 4 1004 4028 4028 4001 1004 1011 4016 4016 4016 4016 4016 4016 4016 1011 4016 4016 1004 4016 4016 4016 4016 4016 4016 4016 1011 4016 4016 4016 4016 4016 4016 1004 1004 1011 4016 4028 4028 4034 1010 4018 4018 1012 1004 1004 4028 2007 4016 4030 4001 4002 4001 4034 4034 1010 4018 4030 4030 4030 4030 4030 4030 4001 4018 4018 4030 4030 4030 4030 4030 4030 4001 4001 4001 2011 4034 LEG INLET OUTLET OUTLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET INLET INLET INLET OUTLET INLET OUTLET OUTLET INLET INLET INLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET OUTLET PROBE 400PS 460SI 460SI 460SI 400PS 400PS 460SI 460SI 460SI 460SI 460SI 460SI 460SI 400PS 460SI 460SI 400PS 460SI 460SI 460SI 460SI 460SI 460SI 460SI 400PS 460SI 460SI 460SI 460SI 460SI 460SI 400PS 400PS 400PS 460SI 460SI 460SI 460SI 400PS 460SI 460SI 400PS 400PS 400PS 460SI 4 60HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 400PS 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460SI

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:32:38 Component: S/G B Page 13 of 20 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW 82 82 83 83 83 83 83 83 83 83 83 83 83 84 84 84 84 84 84 84 84 85 85 85 85 86 86 86 86 86 87 87 87 87 88 88 88 89 89 89 89 89 89 89 89 89 89 89 TUBE VOLTS 125 0.12 5.13 128 0.12 0.17 1

4.50 4

0.27 11 0.43 12 0.29 19 0.58 23 0.50 31 0.44 66 0.08 71 2.43 128 0.09 0.09 0.12 0.12 131 0.13 0.17 37 0.15 56 0.08 0.29 72 0.48 74 0.22 114 0.32 0.66 120 0.20 129 1.03 1.03 130 0.57 0.57 8

0.07 27 0.21 109 0.19 129 0.63 0.63 0.45 0.45 0.55 19 1.04 70 0.40 0.33 120 0.59 126 1.82 131 0.98 0.98 0.70 3

0.33 0.26 40 0.14 70 1.09 129 0.53 0.53 0.54 24 0.11 27 0.10 71 0.12 3

0.10 0.26 5

0.50 66 0.13 0.18 69 0.07 71 0.14 0.14 74 1.32 1.17 81 5.08 98 0.12 0.11 105 0.14 0.14 122 6.73 5.52 127 0.17 DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG 74 183 48 62 23 96 141 133 0

0 0

106 108 79 79 77 77 73 72 60 118 103 67 85 33 177 64 88 88 81 81 53 87 60 26 26 32 32 22 9

135 126 117 18 19 19 19 51 59 46 15 18 18 14 59 51 114 87 120 0

73 39 37 59 59 117 124 171 125 122 73 73 172 183 73 VOL DNT VOL TWD 50 1 DRS VOL VOL 3 TWD 6 3 TWD 8 3 TWD 7 3 TWD 6 VOL VOL SAI TWD 18 SAI TWD 27 VOL TWD 41 VOL VOL VOL 1 VOL VOL VOL TWD 0 VOL SVI TWD 30 SVI TWD 36 VOL 3 TWD 4 VOL MAI TWD 82 MAI TWD 99 PID TEA PID VOL 3 TWD 10 TEA SAI TWD 57 PID VOL TWD 50 VOL VOL SAI TWD 50 PID VOL VOL VOL VOL VOL 3 TWD 7 PID VOL VOL SAI TWD 70 PID VOL DNT VOL PID SAI TWD 47 DNT DNT VOL 014 UTS 010 010 UTE 010 010 010 010 010 010 001 009 013 013 013 013 011 011 012 004 010 013 014 014 014 LTS 013 013 013 013 012 010 003 UTE UTE UTE UTE UTE UTE LTS LTS 014 UTE UTE UTE UTE 012 012 008 012 UTE UTE UTE 010 014 011 010 010 009 LTS LTS 007 UTS UTS LTS LTS 012 UTE UTE 013 013 UTS UTS 014

+1.68

+3.68

+1.13

+1.13

-0.70

-0.82

-0.48

-0.58

-0.73

-0. 74

+0.71

+1. 11

-14.92

-18.34

-18.34

-16.46

-16.46

+1.16

+1.16

-1.88

+16. 85

-14.94

+0.48

-10.13

+0.92

+0.92

+6.31

+0.94

+0.94

+1.52

+1.52

+8.89

+0.53

-1.61

-3.04

-3.04

-3.04

-3.04

-3.04

-0.21

-16.70

-16.70

+0.75

-0.23

-1.27

-1.27

-1.27

+0.66

+0.66

-15.84

+10. 41

-1.20

-1.20

-1.20

+13.75

+6.72

-17.26

+1.20

-2.18

+0.75

-18.29

-18.29

+15.57

-8.57

-8.57

-17.53

-17.53

-18.07

-1.82

-1.82

+4.65

+4.65

+10. 55

+11. 72

+0.83 014 UTS 010 010 UTE TO+11.00 010 010 010 010 010 010 001 009 013 013 013 013 011 011 012 004 010 013 014 014 014 LTS 013 013 013 013 012 010 003 UTE UTE UTE UTE UTE UTE LTS LTS 014 UTE UTE UTE UTE 012 012 008 012 UTE UTE UTE 010 014 011 010 010 009 LTS LTS 007 UTS UTS LTS LTS 012 UTE UTE 013 013 UTS UTS 014 014 UTS 010 010 UTE 010 010 010 010 010 010 001 009 013 013 013 013 012 012 012 004 010 013 014 014 014 LTS 013 013 013 013 012 010 003 UTS UTS UTS UTS UTS UTE LTS LTS 014 UTE UTE UTE UTE 012 012 008 012 UTE UTE UTE 010 014 011 010 010 009 LTS LTS 007 UTS UTS LTS LTS 012 UTE UTE 013 013 UTS UTS 014 SLV WAR WAR WAR WAR WAR WAR CS CS WAR CS 4036 4036 4036 4036 1010 4018 4030 4030 4030 4030 4030 4001 4001 4034 4034 4034 4034 4044 4044 4030 4030 4030 4001 4001 4034 4034 4034 4034 4034 4034 4034 4030 4030 4036 2033 2033 2033 2033 2069 2074 3010 3006 4036 2033 2044 2044 2069 4018 4018 4030 4001 2036 2036 2069 4030 4030 4001 4040 4040 4030 3010 3006 4001 4001 4001 3010 3006 4034 2015 2036 4034 4034 4034 4034 4034 OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET INLET INLET INLET INLET OUTLET OUTLET OUTLET INLET INLET INLET INLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET OUTLET OUTLET OUTLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET PROBE 460SI 460SI 460SI 460SI 400PS 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460HR 4 60HR 4 60HR 460HR 460HR 460TS 460TS 460SI 4 60HR 4 60HR 4 60HR 4 60HR 460SI 460SI 460SI 460SI 460HR 460HR 460HR 460SI 460SI 460SI 460SI 460SI 460SI 4 60TS 4 60TS 460SI 460SI 460SI 4 60TS 4 60TS 460SI 4 60HR 4 60HR 460SI 460SI 460SI 460SI 460SI

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:32:39 Component: S/G B Page 14 of 20 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW 90 90 90 90 91 91 91 91 92 92 93 93 93 93 94 94 94 94 94 95 95 95 95 96 96 96 96 97 98 98 98 99 99 99 99 99 100 100 100 100 101 101 101 101 101 102 102 102 102 102 TUBE VOLTS 3

0.92 54 12.36 4.79 75 0.16 0.18 0.10 0.12 116 0.30 0.37 3

0.05 0.11 71 5.56 102 0.13 0.13 110 0.37 0.41 3

0.39 78 0.14 0.16 48 0.48 55 0.11 109 0.11 0.19 118 0.12 2

10.27 3

0.50 66 0.25 0.30 0.20 71 5.11 103 0.08 55 0.12 69 2.57 89 7.56 1.38 1.18 3.25 4.87 1.85 0.75 8.30 128 0.38 2

0.42 44 0.77 0.71 75 7.22 127 0.21 2

0.43 4

0.94 12 0.25 0.25 66 0.09 6

0.09 41 0.23 56 1.09 0.96 101 0.10 0.10 0.11 0.11 126 0.22 4

0.91 9

1.35 43 0.26 69 0.10 4

0.52 44 0.29 66 0.14 120 0.35 122 0.26 2

0.27 9

1.12 20 0.14 39 0.30 103 3.84 DEG CHN 0

P 3 176 1 181 1 67 2

67 2

62 2

68 2

148 2 45 2

73 2

24 2

5 1

91 2

91 2

144 2 36 2

76 P 3 97 2

98 2

8 2

65 2

106 2 77 2

83 2

180 1 0

P 3 100 2 110 2 108 2 350 1 38 2

68 2

17 1

41 P 1 38 P 3 28 P 3 37 P 3 41 P 3 35 P 3 45 P 3 37 P 1 48 P 3 0

P 3 12 2

17 2

183 1 35 P 3 0

P 3 12 2

99 2

99 2

30 2

47 2

42 2

81 1

108 1 107 2 107 2 95 2

95 2

45 P 3 10 2

16 2

0 P 3 41 2

144 2 27 2

74 2

93 2

80 2

133 2 11 2

38 2

127 2 177 1 IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE TWD 12 DNT DNT VOL VOL VOL VOL VOL TWD 77 VOL TWD 93 DNT SAI TWD 28 VOL TWD 78 TWD 8 VOL PID VOL VOL VOL VOL VOL DNT TWD 7 PID VOL VOL DNT VOL VOL DNT SCI TWD 0 TWD 47 TWD 78 TWD 96 TWD 59 TWD 0 PID TWD 10 TWD 9 VOL TWD 81 DNT TWD 5 TWD 9 TEA VOL TWD 6 VOL VOL VOL VOL PID SAI TWD 0 SAI TWD 8 TWD 6 TEA TEA TWD 5 VOL VOL VOL VOL VOL VOL VOL TEA VOL VOL DNT 010 006 006 005 005 006 006 014 014 014 014 LTS 011 011 015 015 010 UTE UTE 008 008 014 014 014 010 010 UTE UTE UTS 003 010 LTS 014 UTE UTE UTE UTE UTE UTE UTE UTE 008 010 010 010 UTS 008 010 UTE 014 014 011 013 013 LTS LTS 008 008 008 008 008 UTE UTE 013 006 009 014 013 015 UTE 010 UTE 014 014 UTE

+0.37

-14. 62

-13.63

+31. 20

+32.37

+37.63

+16. 95

+0.75

+0.75

+11. 82

+11. 82

-16.00

-7.73

-7.73

+0.76

+0.76

+0.67

-1.30

-1.30

+19.55

+12.88

+1.07

+0.79

+0.97

-0.07

+0.70

-3.82

-3.82

+20.73

+16.87

-4.98

+14. 61

-15.89

-0.16

-0.16 TO+79.5

-0.16 TO+71.2

-0.16 TO+62.8

-0.16 TO+54.4

-0.16 TO+46.0

-0.16 TO+37.7

-0.16

-0.40

+0.57

-0.94

-0.94

+19.77

-0.39

+0.71

-0.20

+1.24

+1.24

+17.70

-1.56

+0. 19

-15.03

-15.03

-3.08

-3.08

-2.80

-2.80

-0.63

-0.18

-0.15

+0.79

+12.36

-0.14

+0.53

+15.59

-1.35

-3.13

+0.65

-0.17

-14.36

-0.32

-4.80 010 006 006 005 005 006 006 014 014 014 014 LTS 011 011 015 015 010 UTE UTE 008 008 014 014 014 010 010 UTE UTE UTE 003 010 LTS 014 UTE UTE UTE UTE UTE UTE UTE UTE 008 010 010 010 UTS 008 010 UTE 014 014 011 013 013 LTS LTS 008 008 008 008 008 UTE UTE 013 006 009 014 013 015 UTE 010 UTE 014 014 UTE 010 006 006 006 006 007 007 014 014 014 014 LTS 011 011 015 015 010 UTE UTE 008 008 014 014 014 010 010 UTE UTE UTS 003 010 LTS 014 UTE UTE UTE UTE UTE UTE UTE UTE 008 010 010 010 UTE 008 010 UTE 014 014 012 013 013 LTS LTS 008 008 008 008 008 UTE UTE 013 007 009 014 014 015 UTE 010 UTE 014 014 UTE WAR WAR TR WAR CS CL WAR WAR WAR WAR WAR WAR 4030 4028 4028 4045 4045 4045 4045 4034 4034 4030 4030 4001 4036 4036 4036 4036 4030 2017 2036 4028 4028 4036 4036 4036 4040 4030 2010 2004 4001 4001 4036 4028 4001 2018 2018 2018 2018 2018 2018 2018 2036 4044 4028 4028 4028 4045 4044 4028 2081 4028 4028 4045 4028 4028 3023 3037 4034 4034 4034 4034 4044 2081 2082 4028 4045 4028 4028 4045 4036 4036 4028 2081 4028 4028 4036 OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 4 60HR 460HR 460SI 460SI 4 60SI 460SI 460SI 460SI 4 60SI 460HR 4 60HR 460SI 460SI 460SI 460SI 460SI 4 60HR 460HR 460HR 460HR 4 60HR 4 60HR 4 60HR 4 60HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 4 60HR 460SI 460SI 460SI 460SI 460SI 460TS 4 60TS 460SI 460SI 460SI 460SI 460SI 4 60HR 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460SI

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:32:39 Component: S/G B Page 15 of 20 Component: S/G B Page 15 of 20 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS 102 121 0.51 103 8 0.98 103 24 0.11 0.11 103 100 0.13 0.13 0.13 104 1 0.22 104 57 0.17 104 89 0.14 105 53 0.22 105 80 0.33 0.29 105 108 0.89 105 121 0.57 106 4 0.64 106 63 0.12 0.13 106 81 0.58 106 100 0.97 106 119 0.12 107 46 0.12 107 98 0.64 0.46 0.46 107 102 5.77 107 114 1.34 108 85 0.10 108 86 0.43 108 115 0.17 0.23 0.35 0.47 108 118 0.32 109 19 0.16 109 31 0.28 109 65 0.08 0.08 0.06 0.06 0.08 0.08 0.04 0.04 109 99 0.20 110 90 10.55 111 72 4.69 111 76 0.66 0.63 0.63 111 98 1.38 112 16 0.10 112 59 0.13 112 104 0.23 112 110 0.32 112 115 0.35 113 20 0.18 113 22 6.38 113 23 1.12 113 36 1.47 113 98 0.60 0.80 0.80 113 99 0.98 0.98 0.58 114 1 0.36 114 11 0.38 114 15 0.15 114 18 0.23 114 34 0.83 114 51 1.31 114 114 0.28 115 33 1.56 115 65 0.10 DEG CHN IND %T; 26 P 3 TWD 13 14 2

TEA 73 2

VOL 66 2

VOL 86 2

SAI 86 2

TWD 4 140 2 PID 97 2

VOL 65 2

VOL 45 2

VOL 134 2 VOL 105 2 VOL 105 2 PID 9

2 TEA 137 P 3 TWD 10 0

P 3 TWD 13 55 2

VOL 53 2

VOL 14 2

TEA 16 2

TEA 56 2

VOL 104 2 VOL 33 2

PID 27 2

SAI 27 2

TWD 87 178 1 DNT 23 2

TEA 57 2

VOL 104 P 3 TWD 7 40 2

VOL 55 2

TWD 56 71 2

VOL 70 2

TWD 43 158 2 VOL 39 2

VOL 132 2 VOL 90 2

SAI 90 2

TWD 29 82 2

SAI 82 2

TWD 38 97 2

SAI 97 2

TWD 21 80 2

SAI 80 2

TWD 40 55 2

VOL 357 1 DNT 359 1 DNT 15 2

PID 14 2

SAI 14 2

TWO 41 23 2

TEA 59 2

VOL 76 P 1 VOL 90 2

VOL 0

P 3 TWD 6 84 2

VOL 45 2

VOL 359 1 DNT 23 2

TEA 14 2

TEA 14 2

PID 18 2

SAI 18 2

TWD 54 24 2

MAI 24 2

TWD 68 28 2

PID 166 2 VOL 0

P 3 TWD 9 44 2

VOL 55 2

VOL 25 2

TEA 11 2

TEA 0

P 3 TWD 6 12 2

TEA 52 2

VOL q LOCATION 009

-0.65 UTE

-0.18 012

+15.88 013

+5.80 UTE

-1.76 UTE

-1.76 UTE

-1.76 010

+11.12 006

-10.68 009

-17.87 UTE

-4.29 UTE

-2.37 UTE

-2.37 UTE

-0.17 008

-0.58 009

-0.54 009

+9.04 009

+8.04 UTE

-0.14 UTE

-0.12 003

+24.10 UTE

-7.86 UTE

-3.25 UTE

-3.25 UTE

-3.25 013

+14.05 UTE

-0.25 009

-15.03 004

-0.70 001

+9.34 001

+9.34 010

+0.80 010

+0.80 010

+0.54 011

-7.82 014

-0.51 UTS

-9.26 UTS

-9.26 UTS

-9.73 UTS

-9.73 UTS

-13.06 UTS

-13.06 UTS

-17.66 UTS

-17.66 005

-11.84 001

+10.00 UTE

-6.67 UTE

-1.11 UTE

-1.11 UTE

-1.11 UTE

-0.20 003

+8.90 012

+15.01 LTS

-7.15 009

-0.66 010

+0.74 011

-11.38 LTS

+6.67 UTE

-0.16 UTE

-0.13 UTE

-2.97 UTE

-2.97 UTE

-2.97 UTE

-2.96 UTE

-2.96 UTE

-2.96 007

-0.75 014

+0.84 015

+20.92 007

+26.80 UTE

-0.24 UTE

-0.27 010

+0.73 UTE

-0.16 014

+2.46 EXT EXT 009 009 UTE UTE 012 012 013 013 UTE UTE UTE UTE UTE UTE 010 010 006 006 009 009 UTE UTE UTE UTE UTE UTE UTE UTE 008 008 009 009 009 010 009 010 UTE UTE UTE UTE 003 004 UTE UTE UTE UTS UTE UTS UTE UTS 013 013 UTE UTE 009 009 004 004 001 001 001 001 010 010 010 010 010 010 011 011 014 014 UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS 005 005 001 001 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 003 003 012 012 LTS LTS 009 009 010 010 011 011 LTS LTS UTE UTE UTE UTE UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS UTE UTS 007 007 014 014 015 015 008 007 UTE UTE UTE UTE 010 010 UTE UTE 014 014 UTIL 1 WAR TR WAR WAR WAR TR WAR TR WAR WAR UTIL 2 CAL #

4046 2086 4028 4028 2021 2021 2043 4028 4028 4036 4028 2036 2069 2036 4036 4028 4045 4045 2036 2036 4045 4028 2116 2069 2069 4036 2040 4036 4036 4036 4036 4036 4036 4036 4028 4028 4036 4036 4036 4036 4036 4036 4036 4036 4036 4024 4021 2116 2048 2048 2048 4008 4008 4024 4024 4024 4008 4008 2094 2093 2116 2048 2048 2047 2047 2116 4042 4008 4008 4042 2095 2095 4024 2096 4021 LEG OUTLET INLET OUTLET OUTLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET INLET INLET OUTLET OUTLET INLET INLET INLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET INLET INLET INLET OUTLET INLET OUTLET PROBE 460SI 460HR 460SI 460SI 4 60HR 4 60HR 460HR 460SI 460SI 460SI 460SI 460HR 460HR 4 60HR 460SI 460SI 460SI 460SI 460HR 4 60HR 460SI 460SI 4 60HR 460HR 460HR 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460HR 460HR 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 4 60HR 460HR 4 60HR 460HR 460HR 460HR 460HR 460HR 460SI 460SI 460SI 460SI 460HR 460HR 460SI 4 60HR 460SI

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:32:39 Component: S/G B Page 16 of 20 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS 115 97 0.21 115 98 0.18 115 110 0.22 115 111 1.46 116 13 0.72 116 24 0.81 116 49 0.12 116 82 0.05 116 94 1.07 1.07 1.00 116 107 0.27 116 108 0.17 0.17 117 3 0.43 117 19 0.15 117 23 1.03 117 37 1.38 117 45 1.65 117 51 1.37 117 56 0.06 117 59 1.39 117 106 0.38 117 108 0.22 118 56 0.84 0.84 0.94 0.67 118 86 0.37 118 99 0.52 118 102 0.12 0.10 0.13 0.13 118 106 0.40 0.38 119 9 1.29 119 16 0.72 119 45 1.38 119 53 2.28 119 88 0.13 119 90 0.12 119 98 0.16 119 106 0.75 120 78 0.30 120 105 0.78 0.47 121 25 0.73 121 54 2.33 122 3 0.26 122 10 1.66 122 22 2.75 122 23 2.46 122 47 0.13 122 56 1.73 122 58 0.11 122 74 1.42 122 82 0.10 122 84 0.13 0.13 0.10 0.10 0.05 0.05 0.11 0.11 122 103 0.58 122 104 0.62 123 57 0.15 123 71 8.44 123 92 1.66 123 98 0.23 123 100 0.09 0.10 123 103 0.21 DEG 79 46 0

0 23 21 77 56 20 20 22 0

77 77 0

51 23 9

16 8

94 16 0

140 15 15 15 0

0 94 80 80 56 56 0

44 15 17 44 6

0 37 47 0

106 0

0 14 20 124 21 25 20 47 13 74 11 48 82 82 69 69 50 50 49 49 0

0 61 167 21 0

109 95 167 CHN 2

2 P3 P 3 2

2 2

2 2

2 2

P3 2

2 P3 2

2 2

2 2

2 2

P3 2

2 2

2 P3 P3 1

2 2

2 2

P3 2

2 2

2 2

P3 2

2 23 2

P3 23 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

P3 P3 2

1 2

P3 2

2 2

IND VOL VOL TWD TWD TEA TEA VOL VOL SAI TWD PID TWD SAI TWD TWD VOL TEA TEA TEA TEA VOL TEA TWD VOL SAI TWD PID TWD TWD VOL VOL TWD SAI TWD TWD VOL TEA TEA TEA TEA TWD VOL VOL TWD VOL TWD TWD TEA TEA VOL TEA TEA TEA VOL TEA VOL TEA VOL VOL TWD VOL TWD VOL TWD VOL TWD TWD TWD VOL DNT TEA TWD VOL VOL VOL

%TW LOCATION EXT EXT 014

+1.15 014 014 013

+12.83 013 013 5

009

-0.63 009 009 25 008

-0.53 008 008 UTE

-0.31 UTE UTE UTE

-0.27 UTE UTE 012

+0.25 012 012 009

-5.03 009 009 UTE

-3.09 UTE UTS 55 UTE

-3.09 UTE UTS UTE

-3.09 UTE UTS 6

008

+0.32 008 008 015

-2.50 015 015 44 015

-2.50 015 015 11 009

+0.63 009 009 004

+5.14 004 004 UTE

-0.20 UTE UTE UTE

-0.17 UTE UTE UTE

-0.27 UTE UTE UTE

-0.20 UTE UTE UTS

-21.95 UTS UTS UTE

-0.19 UTE UTE 8

010

+0.74 010 010 008

+0.33 008 008 UTE

-1.09 UTE UTE 43 UTE

-1.09 UTE UTE UTE

-1.09 UTE UTE 9

004

-0.75 004 004 7

004

-0.71 004 004 015

-8.18 015 015 014

+0.97 014 014 42 014

+0.97 014 014 UTS

-2.02 UTS UTS 64 UTS

-2.02 UTS UTS 8

004

-0.80 004 004 014

+16.77 014 014 UTE

-0.14 UTE UTE UTE

-0.28 UTE UTE UTE

-0.12 UTE UTE UTE

-0.15 UTE UTE 3

014

+0.36 014 014 004

-5.85 004 004 002

-10.14 002 002 14 008

-0.55 008 008 013

+0.60 013 013 15 008

-0.56 008 008 10 010

-0.16 010 010 UTE

-0.21 UTE UTE UTE

-0.16 UTE UTE 009

-0.78 008 009 UTE

-0.18 UTE UTE UTE

-0.19 UTE UTE UTE

-0.20 UTE UTE 009

+5.96 009 009 UTE

-0.15 UTE UTE 013

+8.90 013 013 UTE

-0.21 UTE UTE 015

-11.72 015 015 005

+8.67 005 005 0

005

+8.67 005 005 006

-18.50 006 006 41 006

-18.50 006 006 011

+29.66 012 011 56 011

+30.55 011 011 007

+10.72 010 007 78 007

+10.72 007 007 12 008

-0.61 008 008 13 010

+0.73 010 010 012

-13.43 012 012 002

+18.35 002 002 UTE

-0.25 UTE UTE 5

009

-0.38 009 009 014

+1.55 014 014 014

+0.90 014 014 004

-0.73 004 004 UTIL 1 UTIL 2 WAR WAR WAR WAR WAR TR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR CAL

  • 4024 4024 4024 4024 2095 2095 4013 4021 2049 2049 2116 4024 4024 4024 4008 4013 2096 2096 2096 2096 4021 2050 4024 4024 2050 2050 2116 4021 4024 4024 4024 4024 4024 4024 4024 4024 2096 2095 2096 2096 4024 4024 4024 4024 4021 4024 4024 2100 2053 4010 2101 2101 2100 4013 2053 4021 2053 4021 4021 4021 4021 4021 4042 4042 4042 4042 4024 4024 4021 4021 2054 4024 4024 4024 4024 LEG OUTLET OUTLET OUTLET OUTLET INLET INLET OUTLET OUTLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET OUTLET INLET OUTLET OUTLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET OUTLET INLET INLET INLET OUTLET INLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET PROBE 460SI 460SI 460SI 460SI 4 60HR 4 60HR 460SI 460SI 460HR 460HR 4 60HR 460SI 460SI 460SI 460SI 460SI 460HR 460HR 4 60HR 460HR 460SI 460HR 460SI 460SI 460HR 460HR 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 4 60HR 460HR 460HR 4 60HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460HR 460SI 460HR 460HR 460HR 460SI 4 60HR 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 4 60HR 460SI 460SI 460SI 460SI

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:32:39 Component: S/G B Page 17 of 20 Component: S/G B Page 17 of 20 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW 124 124 124 124 124 124 125 125 125 125 125 125 125 125 125 126 126 126 126 126 126 126 126 127 127 127 127 127 127 127 127 128 128 128 128 128 128 129 129 129 129 129 129 129 129 130 130 TUBE VOLTS 3

0.42 6

0.08 36 1.51 42 2.39 94 0.17 100 0.18 6

0.91 7

0.33 28 0.35 0.35 0.51 0.12 0.11 40 2.35 52 1.02 54 0.32 60 0.11 90 0.21 100 0.31 0.18 0.31 0.18 7

0.34 9

0.87 28 0.26 56 0.12 69 2.07 70 1.78 84 0.07 97 0.14 1

0.10 6

0.14 26 1.54 38 2.97 47 0.12 55 0.16 72 0.09 84 2.56 2

0.67 0.67 0.72 5

1.14 11 0.10 16 0.11 37 1.37 1.37 1.17 52 0.74 2

0.57 4

0.20 18 0.85 38 1.08 1.08 1.16 1.08 40 1.52 49 0.51 75 0.59 94 0.36 5

0.35 0.06 9

0.09 DEG CHN IND %TW LOCATION EXT EXT 46 P 3 TWD 10 009

+0.54 009 009 40 2

VOL 012

+10.43 012 012 11 2

TEA UTE

-0.19 UTE UTE 17 2

TEA UTE

-0.18 UTE UTE 89 2

VOL 014

+1.56 014 014 66 2

VOL 007

+16.42 007 007 8

2 TEA UTE

-0.16 UTE UTE 133 P 3 TWD 8 009

-0.67 009 009 20 2

SAI UTE

-3.44 UTE UTS 20 2

TWD 61 UTE

-3.44 UTE UTS 14 2

PID UTE

-3.44 UTE UTS 120 2 VOL 001

-27.41 TO-26.79 001 001 140 2 TWD 0 001

-27.41 TO-26.79 001 001 15 2

TEA UTE

-0.17 UTE UTE 0

P 3 TWD 13 004

-0.76 004 004 78 2

VOL 015

+12.60 015 015 77 2

VOL 008

-10.10 008 008 48 2

VOL 010

-10.51 010 010 101 2 VOL 011

-17.54 011 011 110 2 VOL 011

-19.34 011 011 101 2 TWD 27 011

-17.54 011 011 110 2 TWD 21 011

-19.34 011 011 149 P 3 TWD 8 009

+0.64 009 009 22 2

TEA UTE

-0.22 UTE UTE 84 2

VOL 004

-0.80 004 004 96 2

VOL 013

+12.18 013 013 25 2

TEA UTE

-0.22 UTE UTE 23 2

TEA UTE

-0.27 UTE UTE 71 2

VOL 003

-7.99 003 003 88 2

VOL 005

+1.14 005 005 125 2 VOL 015

-3.36 015 015 115 2 VOL 015

+0.14 015 015 11 2

TEA UTE

-0.23 UTE UTE 17 2

TEA UTE

-0.15 UTE UTE 54 2

VOL 014

+2.02 014 014 35 2

VOL 014

-15.34 014 014 56 2

VOL 010

-8.42 010 010 23 2

TEA UTE

-0.25 UTE UTE 19 2

SAI UTE

-1.21 UTE UTE 19 2

TWD 55 UTE

-1.21 UTE UTE 15 2

PID UTE

-1.21 UTE UTE 14 2

TEA UTE

-0.18 UTE UTE 54 2

VOL LTS

+6.48 LTS LTS 88 2

VOL 014

+1.04 014 014 22 2

MAI UTE

-3.38 UTE UTS 22 2

TWD 66 UTE

-3.38 UTE UTS 31 2

PID UTE

-3.38 UTE UTS 80 2

VOL 003

+12.55 003 003 82 P 3 TWD 10 010

+0.67 010 010 97 2

VOL 004

-0.74 004 004 8

2 VOL 011

+13.36 011 011 28 2

MAI UTE

-3.58 UTE UTS 28 2

TWD 91 UTE

-3.58 UTE UTS 19 2

TWD 56 UTE

-3.58 UTE UTS 24 2

PID UTE

-3.58 UTE UTS 16 2

TEA UTE

-0.16 UTE UTE 0

P 3 TWD 7 004

-0.67 004 004 88 2

VOL 001

+0.75 001 001 0

P 3 TWD 8 010

-0.62 010 010 36 P 3 TWD 8 010

+0.56 010 010 88 2

VOL UTS

-15.21 UTS UTS 138 P 3 TWD 2 004

-0.76 004 004 UTIL 1 UTIL 2 WAR WAR WAR WAR TR WAR TR WAR WAR WAR CAL #

4010 4010 2100 2100 4024 4024 2100 4010 2100 2100 2125 4013 4013 2100 4021 4021 4021 4024 4024 4024 4024 4024 4010 2104 4013 4021 2053 2054 4021 4024 4010 4010 2104 2105 4013 4021 4021 2054 2104 2104 2125 2105 4013 4013 2104 2104 2125 4021 4008 4010 4013 2105 2105 2105 2125 2105 4021 4021 4024 4010 4010 LEG OUTLET OUTLET INLET INLET OUTLET OUTLET INLET OUTLET INLET INLET INLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET INLET INLET OUTLET OUTLET OUTLET OUTLET INLET INLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET OUTLET OUTLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET PROBE 460SI 460SI 460HR 460HR 460SI 460SI 460HR 460SI 4 60HR 460HR 460HR 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460HR 460HR 460SI 460SI 460SI 460SI 460HR 4 60HR 460SI 460SI 460SI 4 60HR 4 60HR 4 60HR 4 60HR 4 60HR 460SI 460SI 4 60HR 4 60HR 460HR 460SI 460SI 460SI 460SI 4 60HR 4 60HR 4 60HR 460HR 460HR 460SI 460SI 460SI 460SI 460SI WAR 4013 OUTLET 460SI

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:32:39 Component: S/G B Page 18 of 20 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS 0.32 131 11 1.55 131 36 0.55 131 63 0.67 132 3 0.79 132 6 0.26 132 10 0.60 0.60 0.62 132 13 1.03 132 20 1.22 132 33 0.48 0.48 0.58 132 44 1.67 132 49 0.18 0.12 132 85 0.75 133 3 7.85 133 5 0.25 0.23 133 9 0.44 133 40 1.37 133 45 1.65 133 86 0.09 134 2 8.07 0.22 134 3 10.56 134 5 8.18 134 62 1.83 134 76 0.08 135 5 0.27 135 8 1.98 135 14 1.20 135 33 0.12 135 36 0.13 135 80 0.23 0.23 135 82 0.69 0.66 0.66 0.50 0.39 0.27 136 5 0.44 0.44 136 29 1.59 136 33 5.64 136 37 0.13 136 70 0.31 137 1 0.14 0.18 137 7 1.39 0.20 137 13 1.48 137 15 1.98 137 17 2.02 137 58 0.81 138 9 1.45 138 14 1.55 138 15 1.61 138 17 0.30 138 21 0.13 138 31 0.63 138 41 1.66 138 56 1.08 138 70 0.12 0.09 139 2 0.74 6.87 139 4 0.97 139 5 0.80 139 12 0.27 139 29 0.17 139 35 1.20 DEG 134 23 28 0

44 130 26 26 26 14 9

21 21 23 15 107 123 0

358 151 122 106 10 21 24 359 120 177 359 22 39 16 16 16 74 147 64 64 29 26 26 18 23 26 27 27 27 180 54 86 99 54 14 49 11 19 14 11 14 17 11 94 52 16 13 18 49 45 11 13 12 14 9

113 19 CH P

2 2

p 1

2 2

2 2

2 2

2 2

2 2

2 2

P 1

P P

P 2

2 P

1 2

1 1

2 2

P 2

2 2

P 2

2 2

2 2

2 2

2 2

2 2

1 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

1 2

2 2

2 2

IN IND %Th 3 TWD 7 TEA TEA 3 TWD 9 DNT VOL SAI TWD 83 PID TEA TEA SAI TWD 63 PID TEA VOL VOL 3 TWD 15 DNT 3 TWD 5 3 TWD 5 3 TWD 10 TEA TEA 3 TWD 2 DNT VOL DNT DNT TEA VOL 3 TWD 6 TEA TEA VOL 3 TWD 3 SAI TWD 71 PID MAI TWD 84 TWD 54 TWD 72 TWD 84 VOL TWD 89 TEA DNT VOL VOL VOL VOL TEA VOL TEA TEA TEA TEA TEA TEA TEA VOL VOL TEA TEA TEA VOL VOL TEA DNT TEA TEA TEA VOL TEA i

LOCATION EXT EXT 010

+0.71 010 010 UTE

-0.13 UTE UTE UTE

-0.26 UTE UTE 002

-0.38 002 002 LTS

+34.14 LTS LTS 010

-0.66 010 010 UTE

-1.15 UTE UTE UTE

-1.15 UTE UTE UTE

-1.15 UTE UTE UTE

-0.20 UTE UTE UTE

-0.24 UTE UTE UTE

-3.23 UTE UTS UTE

-3.23 UTE UTS UTE

-3.23 UTE UTS UTE

-0.16 UTE UTE 015

+3.16 015 015 015

+5.11 015 015 011

+0.37 011 011 010

+0.43 010 010 010

+0.70 010 010 010

-0.70 010 010 009

+0.67 009 009 UTE

-0.18 UTE UTE UTE

-0.19 UTE UTE 010

+0.55 010 010 LTS

+4.89 LTS LTS 004

-0.64 003 004 010

+0.09 010 010 010

+0.29 010 010 UTE

-0.20 UTE UTE 015

-9.06 015 015 010

+0.66 010 010 UTE

-0.19 UTE UTE UTE

-0.16 UTE UTE 012

-1.44 012 012 004

-0.73 004 004 014

+15.98 014 014 014

+15.98 014 014 UTE

-3.47 UTE UTS UTE

-3.47 UTE UTS UTE

-3.47 UTE UTS UTE

-3.47 UTE UTS UTE

-3.47 UTE UTS UTE

-3.47 UTE UTS 014

+0.98 014 014 014

+0.98 014 014 UTE

-0.15 UTE UTE UTS

-19.82 UTS UTS 002

+18.64 002 002 003

+0.72 003 003 010

+5.84 010 010 012

-13.60 012 012 UTE

-0.31 UTE UTE 015

-12.78 015 015 UTE

-0.28 UTE UTE UTE

-0.31 UTE UTE UTE

-0.29 UTE UTE UTE

-0.15 UTE UTE UTE

-0.24 UTE UTE UTE

-0.15 UTE UTE UTE

-0.16 UTE UTE UTE

-11.98 UTE UTE 001

-5.60 001 001 UTE

-0.22 UTE UTE UTE

-0.14 UTE UTE UTE

-0.21 UTE UTE 014

+4.72 014 014 014

+5.44 014 014 UTE

-0.14 UTE UTE 010

+0.11 010 010 UTE

-0.19 UTE UTE UTE

-0.13 UTE UTE UTE

-0.45 UTE UTE 009

+7.54 009 009 UTE

-0.01 UTE UTE UTIL 1 WAR WAR TR TR WAR WAR WAR WAR WAR WAR WAR UTIL 2 CAL #

4010 2104 2104 4021 4010 4010 2105 2105 2125 2104 2104 2105 2105 2125 2061 4021 4021 4024 4010 4010 4010 4013 2105 2061 4024 4010 4010 4010 4010 2061 4021 4010 2109 2109 4013 4013 4021 4021 2116 2062 2062 2062 2062 2062 4010 4010 2109 4013 4013 4021 4010 4010 2108 4010 2108 2108 2108 2065 2108 2109 2108 4013 4013 2108 2065 2065 4021 4021 2109 4010 2108 2109 2108 4013 2108 LEG OUTLET INLET INLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET INLET INLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET INLET INLET INLET INLET INLET INLET INLET OUTLET OUTLET INLET INLET INLET OUTLET OUTLET INLET OUTLET INLET INLET INLET OUTLET INLET PROBE 460SI 460HR 460HR 460SI 460SI 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460HR 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460HR 460HR 460SI 460SI 460SI 460SI 460HR 460HR 460HR 460HR 460HR 460HR 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460HR 460HR 460HR 460HR 4 60HR 460HR 460HR 460SI 460SI 460HR 460HR 4 60HR 460SI 460SI 4 60HR 460SI 460HR 4 60HR 460HR 460SI 4 60HR

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:32:39 Component: S/G B Page 19 of 20 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryMl ROW TUBE VOLTS 140 9 1.39 140 14 1.92 140 27 2.82 0.16 0.23 140 38 1.22 140 51 0.20 0.25 141 9 1.67 141 13 2.40 141 17 0.11 141 24 1.52 141 27 0.09 141 40 2.28 141 66 0.99 142 5 0.19 142 8 0.23 142 13 1.18 142 24 1.37 142 27 0.40 142 44 0.68 142 52 3.17 142 62 0.11 142 63 0.23 0.10 0.14 143 3 0.13 143 6 2.55 0.17 143 13 0.25 143 25 0.34 143 33 0.15 143 52 0.20 144 14 0.26 144 16 0.10 144 40 0.86 144 50 1.10 144 52 0.20 145 19 1.60 1.60 1.54 145 31 1.14 145 37 0.68 145 41 0.61 145 42 0.50 145 43 0.12 145 44 0.16 145 46 0.15 145 48 0.23 145 49 0.89 145 51 0.66 146 10 0.26 146 11 0.17 146 16 2.13 146 18 1.48 146 40 0.13 146 42 0.22 146 44 0.28 146 48 0.31 147 2 1.32 147 15 0.72 0.72 0.78 147 43 0.14 148 23 0.08 148 25 0.83 0.85 0.75 0.07 0.07 148 28 0.11 148 35 0.17 0.10 148 37 0.13 149 1 0.22 DEG 16 16 18 49 83 19 87 89 20 17 55 17 51 19 27 101 25 9

13 84 25 21 42 80 74 49 38 19 95 46 87 63 98 83 53 0

22 64 26 26 27 21 0

0 0

151 45 54 51 0

84 29 72 24 23 11 70 58 162 20 22 22 30 83 58 20 20 18 78 78 7

49 57 94 95 CHN 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

P 3 P3 2

2 2

2 2

2 2

2 2

2 2

2 P 3 P 3 2

2 P 3 2

P 3 2

2 2

2 2

2 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 P 3 2

2 2

P 3 P 3 P 3 P 3 2

2 2

2 2

2 2

2 2

2 2

P 3 2

2 2

2 IND %TW LOCATION TEA UTE

-0.18 TEA UTE

-0.15 TEA UTE

-0.12 VOL 010

-1.24 VOL 014

-2.90 TEA UTE

-0.10 VOL 015

+9.92 VOL 015

+10.82 TEA UTE

-0.34 TEA UTE

-0.39 VOL 015

-3.68 TEA UTE

-0.15 VOL 013

-7.18 TEA UTE

-0.13 TEA UTE

-0.09 TWD 4 009

+0.63 TWD 6 009

-0.51 TEA UTE

-0.13 TEA UTE

-0.14 VOL 006

-11.68 TEA UTE

-0.24 TEA UTE

-0.33 VOL 015

+8.45 VOL 005

+16.50 VOL 010

-8.73 VOL 010

-10.41 VOL 011

+18.82 TEA UTE

-0.19 VOL 004

-18.35 TWD 6 006

-0.49 TWD 8 009

-0.63 VOL 003

-2.78 VOL UTE

-7.95 TWD 7 009

-0.53 VOL 011

-11.31 TWD 11 009

+0.56 TEA UTE

-0.23 VOL 009

-0.09 SAI UTE

-2.71 TWD 82 UTE

-2.71 PID UTE

-2.71 TEA UTE

-0.08 TWD 9 009

+0.43 TWD 8 009

+0.65 TWD 7 009

+0.68 TWD 3 010

-0.67 TWD 4 009

+0.60 TWD 4 009

+0.76 TWD 6 009

+0.66 TWD 11 010

+0.68 TWD 9 010

+0.66 TWD 6 008

+0.54 VOL 014

+1.38 TEA UTE

-0.18 TEA UTE

-0.21 TWD 3 010

-0.66 TWD 5 010

-0.69 TWD 7 010

+0.76 TWD 8 010

+0.77 TEA UTE

-0.16 SAI UTE

-5.05 TWD 67 UTE

-5.05 PID UTE

-5.05 VOL 014

+1.03 VOL 012

-7.38 SAI UTE

-3.16 TWD 63 UTE

-3.16 PID UTE

-3.16 VOL 013

+5.49 TWD 29 013

+5.49 TWD 3 004

-0.74 VOL 010

+12.52 VOL 010

+14.60 VOL 015

+0.32 VOL 015

+15.09 EXT UTE UTE UTE 010 014 UTE 015 015 UTE UTE 015 UTE 013 UTE UTE 009 009 UTE UTE 006 UTE UTE 015 005 010 010 011 UTE 004 006 009 003 UTE 009 011 009 UTE 009 UTE UTE UTE UTE 009 009 009 010 009 009 009 010 010 008 014 UTE UTE 010 010 010 010 UTE UTE UTE UTE 014 012 UTE UTE UTE 013 013 004 010 010 015 015 EXT UTE UTE UTE 010 014 UTE 015 015 UTE UTE 015 UTE 013 UTE UTE 009 009 UTE UTE 006 UTE UTE 015 005 010 010 011 UTE 004 006 009 003 UTE 009 011 009 UTE 009 UTS UTS UTS UTE 009 009 009 010 009 009 009 010 010 008 014 UTE UTE 010 010 010 010 UTE UTS UTS UTS 014 012 UTS UTS UTS 013 013 004 010 010 015 015 UTIL 1 UTIL 2 WAR WAR WAR WAR WAR WAR TR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR TR CS WAR CAL 4 2108 2109 2109 4013 4013 2066 4021 4021 2108 2108 4013 2109 4013 2066 2061 4010 4013 2109 2109 4013 2065 2065 4021 4021 4021 4021 4010 2108 4010 4013 4013 4017 4021 4013 4013 4017 2065 4021 2112 2112 2125 2066 4017 4017 4017 4017 4017 4017 4017 4017 4017 4013 4013 2112 2112 4017 4017 4017 4017 2113 2112 2112 2125 4017 4017 2116 2116 2125 4017 4017 4017 4017 4017 4017 4010 LEG INLET INLET INLET OUTLET OUTLET INLET OUTLET OUTLET INLET INLET OUTLET INLET OUTLET INLET INLET OUTLET OUTLET INLET INLET OUTLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET INLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET INLET OUTLET OUTLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET PROBE 460HR 460HR 460HR 460SI 460SI 460HR 460SI 460SI 460HR 460HR 460SI 460HR 460SI 460HR 460HR 460SI 460SI 460HR 460HR 460SI 460HR 460HR 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460HR 460HR 460HR 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460HR 460SI 460SI 460SI 460SI 460HR 460HR 4 60HR 460HR 460SI 460SI 460HR 4 60HR 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI

Framatome ANP Inc.

Customer Name: Oconee Unit 3 12/05/01 14:32:39 Component: S/G B Page 20 of 20 ATTACHMENT #4 -

LIST OF IMPERFECTIONS -

MRPC/PLUS POINT QUERY: QueryM1 ROW TUBE VOLTS 149 9 0.90 0.90 0.83 149 16 0.14 149 17 5.72 149 29 0.11 149 30 0.36 0.44 0.44 150 5 0.90 150 17 0.41 0.16 151 3 0.25 151 8 9.21 151 9 7.66 8.12 151 16 0.38 DEG 25 25 23 41 183 103 49 0

0 13 87 81 153 2

357 5

102 CHN 2

2 2

2 1

2 P 3 P 3 P 3 2

P 3 2

P 3 1

1 1

2 IND %TW LOCATION EXT EXT SAI UTE

-3.42 UTE UTS TWD 78 UTE

-3.42 UTE UTS PID UTE

-3.42 UTE UTS VOL 010

+1.23 010 010 DNT LTS

-13.31 LTS LTS VOL 015

+0.50 015 015 TWD 9 010

-0.66 010 010 TWD 6 010

+0.52 010 010 TWD 6 011

+0.59 011 011 TEA UTE

-0.14 UTE UTE TWD 10 010

+0.65 010 010 VOL 014

+5.79 014 014 TWD 6 013

-0.66 012 013 DNT LTS

-13.29 LTS LTS DNT UTS

+12.98 UTS UTS DNT LTE

+10.25 LTE LTE VOL 015

-1.22 015 015 UTIL 1 TR WAR WAR WAR WAR WAR UTIL 2 CAL #

2112 2112 2125 4013 4013 4017 4017 4017 4017 2113 4017 4017 4010 4010 4017 4042 4017 LEG INLET INLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET OUTLET OUTLET OUTLET OUTLET INLET OUTLET PROBE 4=60HR 460HR 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460HR 460SI 460SI 460SI 460SI 460SI 460SI 460SI Total Tubes

1009 Total Records: 1442

Steam Generator A Page l of 5 ATTACHMENT #5 - TUBES PLUGGED FOR EDDY CURRENT INDICATIONS ROW TUBE 32 1

79 1

124 1

30 1

80 2

98 2

113 2

57 3

58 3

44 4

63 4

122 4

79 4

114 6

33 7

73 8

5 9

14 11 56 11 90 13 99 13 3

14 6

14 7

16 81 16 84 17 91 17 118 20 146 20 147 21 135 22 74 23 72 24 133 26 135 26 80 27

Steam Generator A Page 2 Of 5 ATTACHMENT #5 - TUBES PLUGGED FOR EDDY CURRENT INDICATIONS ROW TUBE 81 27 137 27 134 29 144 31 4

37 28 37 89 37 134 37 146 37 4

38 44 38 134 38 4

39 6

39 131 39 6

41 128 42 45 44 79 45 124 45 143 47 6

49 18 49 10 9 50 31 56 17 57 110 58 111 58 120 58 45 59 106 59 99 60 104 61 107 61 143 61 79 62 114 62

Steam Generator A Page 3 Of 5 ATTACHMENT #5 - TUBES PLUGGED FOR EDDY CURRENT INDICATIONS ROW TUBE 47 63 14 66 73 66 80 66 46 68 67 68 137 70 72 72 77 72 17 73 17 74 38 74 14 75 17 75 18 75 138 75 17 76 18 76 49 76 17 77 19 77 137 77 17 78 69 78 137 78 135 79 1 9 80 91 80 136 80 79 82 91 82 132 82 25 83 92 83 131 83 133 83 82 83

Steam Generator A Page 4 Of 5 ATTACHMENT #5 - TUBES PLUGGED FOR EDDY CURRENT INDICATIONS ROW TUBE 85 84 57 85 80 85 131 85 133 85 131 86 131 87 93 88 34 89 92 89 96 89 117 89 129 89 94 90 131 90 78 91 108 91 96 92 129 92 129 94 79 95 71 96 92 96 83 98 55 102 123 102 58 103 81 103 114 103 116 104 110 1 05 35 108 68 110 107 111 108 111 108 112 53 113

Steam Generator A Page 5 of 5 ATTACHMENT #5 - TUBES PLUGGED FOR EDDY CURRENT INDICATIONS ROW TUBE 93 113 77 115 42 116 42 117 43 117 68 117 69 118 84 118 77 119 107 120 78 120 78 121 79 123 82 123 103 123 65 126 81 131 83 132

Steam Generator A Page I of 2 ATTACHMENT #6 - TUBES PLUGGED TO CAPTURE NON-STABILIZED PLUGGED TUBE LOCATIONS ROW TUBE 29 2

30 2

31 2

29 3

32 3

117 3

31 4

33 4

116 4

117 4

118 4

115 5

118 5

88 6

111 12 110 13 112 13 113 13 113 14 142 57 143 57 143 58 142 60 141 61 53 81 54 81 55 81 53 82 55 82 54 83 122 102 122 103 120 104 122 104 120 105 93 110 94 113 92 114 94 114 74 119 75 119

Steam Generator A Page 2 of 2 ATTACHMENT #6 - TUBES PLUGGED TO CAPTURE NON-STABILIZED PLUGGED TUBE LOCATIONS ROW TUBE 106 119 105 121 73 122 72 123 61 124 73 124 74 125 79 125 82 125 85 125 61 126 79 126 84 127 60 128 63 128 81 128 82 128 83 128 60 129 73 129 83 129

Steam Generator B Page I of 2 ATTACHMENT #7 - TUBES PLUGGED FOR EDDY CURRENT INDICATIONS ROW TUBE 61 1

44 1

3 3

44 3

73 3

87 3

91 3

79 4

136 5

4 6

149 9

98 12 73 14 3

15 147 15 24 18 81 18 11 19 145 19 2

20 148 25 42 26 125 28 75 29 52 29 74 30 132 33 38 34 128 37 129 38 130 38 33 39 5

42 96 44 31 52 15 52 34 57 10 63 10 65 109 65 16 66

Steam Generator B Page 2 of 2 ATTACHMENT #7 - TUBES PLUGGED FOR EDDY CURRENT INDICATIONS ROW TUBE 89 71 15 76 35 77 135 80 135 82 46 83 122 84 26 85 71 85 21 88 34 88 116 94 76 98 107 98 113 98 113 99 125 100 99 101 91 102 118 102 89 105 67 107 116 108 91 110 75 111 75 112 49 114 84 114 108 115 90 116 70 123 54 124 61 126 63 128 82 128 83 128 84 129 85 129 84 130 83 131

Steam Generator B Page 1 of 2 ATTACHMENT #8 - TUBES PLUGGED TO CAPTURE NON-STABILIZED PLUGGED TUBE LOCATIONS ROW TUBE 8

1 8

2 4

3 10 4

63 4

9 5

5 6

10 6

11 6

5 7

151 7

35 8

151 8

35 9

36 9

151 9

37 10 99 10 100 10 101 10 98 11 101 11 150 16 80 62 81 62 82 62 80 63

~82 63 50 95 49 96 49 97 52 98 53 98 122 100 122 101 119 103 120 103 61 115 61 116 62 120 64 120

Steam Generator B Page 2 of 2 ATTACHMENT #8 - TUBES PLUGGED TO CAPTURE NON-STABILIZED PLUGGED TUBE LOCATIONS ROW TUBE 59 122 52 124 56 124 53 125 56 125 56 126 57 127

Steam Generator A Page I of I ATTACHMENT #9 - TUBES REPAIRED BY REROLLING IN THE HOTLEG ROW TUBE 116 2

113 7

122 12 83 15 84 16 113 23 4

38 142 48 62 54 139 60 18 73 117 102

Steam Generator B Page I of I ATTACHMENT #10 - TUBES REPAIRED BY REROLLING IN THE HOTLEG ROW TUBE 128 2

49 3

10 6

132 10 2

22 118 56 111 76 92 78 95 89 56 90 103 100 66 108 87 129 86 131

U. S. Nuclear Regulatory Commission Page 1 March 4, 2002 Attachment B Unit 3 End of Cycle 19 Steam Generator Inservice Inspection Steam Generator Three-Month Report INSPECTION ASSESSMENT The following summarizes the Once-Through Steam Generator (OTSG) Eddy Current Testing (ECT) inspection scope during the Oconee Unit 3 EOC 19 Refueling Outage:

Bobbin Coil (0.510 dia. MF)

Lane and Wedge:

(0.460 dia. Plus-point)

MRPC Upper Tubesheet Roll (0.460 dia. Plus-point)

MRPC Re-rolls Upper Tubesheet (0.460 dia. Plus-point)

MRPC Lower Tubesheet Roll (0.460 dia. Plus-point)

Bobbin Sleeve Exam (0.410 dia.)

Sleeve Upper and Lower Rolls (0.400 dia Plus-point)

Kidney Region (Sludge Pile)

(0.460 dia. Plus-point) 100% A-OTSG 100% B-OTSG Two Rows Around Sleeved Tubes A and B OTSG 100% A-OTSG 100% B-OTSG 100% A-OTSG 100% B-OTSG 100% Original Re-expansion 100% Sleeves A-OTSG 100% Sleeves B-OTSG 100% Sleeve Rolls A-OTSG 100% Sleeve Rolls B-OTSG 100% A-OTSG 100% B-OTSG The inspection covers at least 10 inches into the tubesheet RPC Special Interest (0.460 dia. Plus-point) 1)

2) 100% Bobbin indications regardless of location 100% Dents The primary to secondary leak rate was less than 2.0 gpd at shutdown.

Disposition of the above inspection data identified 246 tubes (165 in the A-OTSG and 81 in the B-OTSG) that required removal from service. Active damage mechanisms identified during this inspection include Intergranular Stress Corrosion Cracking (IGSCC), Intergranular Attack (IGA), impingement, wear, and upper tubesheet roll

U. S. Nuclear Regulatory Commission Page 2 March 4, 2002 Attachment B Primary Water SCC (PWSCC). Tubes were removed from service by installing alloy-690 rolled plugs.

In-situ testing was performed to confirm structural and leakage integrity at the end of the current operating cycle. The tubes were selected consistent with EPRI guidelines. The indications were sized and compared to the condition monitoring structural limit that considers the uncertainties associated with material properties, non-destructive examination (NDE), and the burst correlation. All tubes that exceed the limit were in-situ pressure tested. The screening includes voltage, depth, length, circumferential extent measurements as well as review of the indication eddy current signal, past tube pull results, and past experience with in-situ testing at the Oconee units. As a result of this screening, 13 indications were in-situ pressure tested and no leakage was observed.

Hence, structural and leakage integrity was demonstrated.

The observed degradation was analyzed consistent with NEI 97-06 and EPRI guidelines to justify full cycle operation. All inputs were considered at 95th percentile bounding values. The projected deterministic worst-case end of cycle structural and leakage integrity margins satisfy the criteria in NEI 97-06 and full cycle operation is warranted.

IGSCC The limiting degradation of concern is axial IGSCC in the freespan. A total of 132 tubes were removed from service due to axially oriented freespan IGSCC. Based on previous tube pull examination, these indications are associated with grooves on the OD surface of the tubes. These indications are removed from service on detection.

All of these tubes provided adequate margin against rupture. This determination is based on previous tube pull data, structural calculations, and in-situ pressure tests.

Extensive growth rate studies have been performed for past inspections at Oconee with similar results. The analysis of the Oconee Unit 3 EOC 19 data is bounded by the Oconee Unit 1 data. The Oconee Unit 1 EOC 18 analysis indicates a best estimate upper 95th percentile growth rate of 15.6% Through Wall (TW) per EFPY. Assuming a flaw is 40% TW at the Beginning of Cycle (BOC), a growth rate of 15.6% TW per EFPY for the next cycle, and at the 95 percentile flaw length of 1.0 inches, full cycle operation is justified. The predicted burst pressure of the assumed flaw at the end of the next cycle is above three times normal operating differential pressure considering uncertainties in the material properties and the burst pressure relationship.

Wear No tubes were removed from service due to wear. Wear is removed from service based on sizing with a rotating coil. The plugging limit is 2 40% TW. Using the analysis described above and including sizing uncertainties, the predicted burst pressure of the assumed flaw at the end of the next cycle is above three times normal operating differential pressure (assuming 61% TW, 1.5 inches long, and less than 1350 circumferential extent).

U. S. Nuclear Regulatory Commission Page 3 March 4, 2002 Attachment B IGA A total of 22 tubes were removed from service due to IGA. These indications are volumetric in nature with limited circumferential extent. The Plus-point probe was used in the sludge pile region of the lower tubesheet to provide enhanced detection versus the bobbin probe. The circumferential extent of IGA is typically below 70 degrees. IGA is removed from service based on detection by Plus-point.

Based on the structural limit and the limited circumferential extent of IGA, all of these tubes provided adequate margin against rupture. The conclusion is supported by tube pull data, analysis, and in-situ pressure testing with no observed leakage. The growth rate of volumetric IGA is extremely low. Assuming an initial flaw size of 25% TW, full cycle operation is justified based on the wear analysis described above is bounding.

Impingement A total of 42 tubes were removed from service due to impingement. Impingement indications are volumetric in nature with limited axial and circumferential extent similar to IGA. Based on the broached opening width, the maximum possible circumferential extent is estimated to be 98 degrees. The structural limits are equivalent to IGA or wear.

These tubes provided adequate margin against rupture. This determination is based on previous tube pull data, analysis, in-situ test data, and eddy current sizing abilities.

Typically, the maximum observed depth is 60% TW. The average growth rate of impingement is approximately 10% TW per cycle. Previous pulled tube specimens at 60% TW burst at greater than 9000 psi, which is typical for impingement defects.

Analysis of impingement is bounded by IGA and wear. Therefore, full cycle operation is justified.

Impingement is removed from service based on bobbin sizing (2 40% TW). Additionally, impingement defects < 40% TW are removed from service preventatively based on previous data and defect location.

Sleeve Indications No tubes were removed from service due to an axial indication in the sleeve roll. The sleeves contain three rolls. Roll one is at the upper tubesheet primary face and rolls two and three are in the freespan on the opposite end of the sleeve below the 15th TSP.

Tubes with degradation in the sleeves are removed from service.

Dents A total of 6 tubes with indications in dents were removed from service due to short axial or volumetric indications. All of these tubes provided adequate margin against rupture.

The indications were axial or volumetric in nature and bounded by the IGSCC analysis.

U. S. Nuclear Regulatory Commission Page 4 March 4, 2002 Attachment B This conclusion is supported by analysis and in-situ pressure testing with no observed leakage. Therefore, full cycle operation is justified.

Indications in dents are removed from service based on detection with a Plus-point probe.

Miscellaneous A total of 18 tubes were preventatively removed from service due to miscellaneous reasons. These are typically obstructed tubes, permeability, volumetric indications near the lane and wedge region, or other ambiguous eddy current indications that may mask degradation.

Upper Roll PWSCC A total of 52 tubes were identified with indications of PWSCC in the upper tubesheet roll area. Twenty-six tubes were repaired by installing a new roll in the upper tubesheet.

Two of these tubes were then removed from service with alloy-690 rolled plugs.

Twenty-six tubes were removed from service due to indications in previously installed rerolls. Tubes are repaired based on Plus-point detection.

All of these indications are captured in the tubesheet. The indications will not burst due to tubesheet constraint and do not present a structural concern. Laboratory helium leak tests did not identify leakage in tubes pulled in the past from Oconee Unit 1 and Oconee Unit 3. During a previous Oconee Unit 1 outage, in-situ pressure testing was performed on twelve tubes representing the deepest degradation: No tube leakage was identified.

LBLOCA Evaluation The as-found condition of the steam generators was evaluated to determine the best estimate primary to secondary leakage following a LBLOCA as described in Appendix A to BAW-23741. For the purpose of this evaluation, volumetric indications were conservatively analyzed as circumferential indications with the maximum depth applied to the full circumferential extent of the indication. Circumferential indications were also considered in this analysis. The best estimate primary to secondary leakage is 1.3 gpm.

This estimated leakage would maintain offsite dose well below the limits of 10 CFR 100.

Swollen Plugged Tube Inspection As a result of issues raised by the occurrence of a plugged tube becoming severed at another nuclear plant, inspections were performed to detect the possibility of occurrence at Oconee. This event consisted of finding wear scars in four steam generator tubes adjacent to the severed plugged tube. The wear scars were caused by a plugged tube that had become severed at the bottom of the upper tubesheet (UTS) and vibrated

' Framatome Technologies Inc. Topical Report, BAW-2374, "Justification for Not Including Postulated Breaks in Large-Bore Reactor Coolant Piping in the Licensing Basis for Existing and Replacement Once-Through Steam Generators," July 2000.

U. S. Nuclear Regulatory Commission Page 5 March 4, 2002 Attachment B against the neighboring tubes downstream of the direction of the flow of steam from the tube bundle. The root cause of the severing of the plugged tube was identified by the utility as consisting of initial swelling of the SG tube due to internal pressure, resulting in significant axial stresses and a reduction in structural damping in the presence of a flow field sufficient to cause flow induced vibration (FIV) fatigue of the tube at the bottom of the UTS location. The essential features of the failure are swelling of the tube due to a flow diode effect and the severity of the flow field. In other words, the event would not have happened if swelling of the tube had not taken place.

The inspection at Oconee did not indicate any wear on the tubes adjacent to plugged tubes or any tube severance. A total of 22 plugged tubes inspected contained water and no tubes were swollen. This condition did not exist during the recent inspection and is not expected to occur during the next operating cycle.

U. S. Nuclear Regulatory Commission March 4, 2002 Attachment C Unit 3 End of Cycle 19 Steam Generator Inservice Inspection Steam Generator Three-Month ASME Xl Report Page 1

Steam Generator Outage Summary Report Oconee Unit 3 2001 EOC 19 Refueling Outage Location: 7800 Rochester Highway, Seneca, South Carolina 29672 NRC Docket No. 50-287 National Board No. N/A Commercial Service Date: December 16, 1974 Owner: Duke Energy Corporation 526 South Church St.

Charlotte, N.C. 28201-1006 Revision 0 Prepared By:

Reviewed By:

Approved By:

4/.

Date:

1/24 /0Z Date:I q2I) 02.

Date: I9 I-z 4

V1 Copy No.

1 Assigned To:

NRC Docurnen' Cirol Controlled:

Uncontrolled:

Controlled Distribution Copy No.

Assigned To Original Oconee Nuclear Station Document Control Master File OS-208.20 1

NRC Document Control Uncontrolled Distribution 2

Hartford Steam Boiler Inspection and Insurance Corporation (AIA)

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules

1. Owner: Duke Energy Corporation. 526 S. Church St. Charlotte, NC 28201-1006-(Name and Address of Owner)
2.

Plant:

Oconee Nuclear Station, 7800 Rochester Highway, Seneca, SC 29672 (Name and Address of Plant) 3.

4.

5.

6.

7.

Plant Unit:

3 Owner Certificate of Authorization (if required)

N/A Commercial Service Date:

December 16. 1974 National Board Number for Unit N/A Components Inspected:

Component Steam Generator A Steam Generator B Manufacturer Babcock & Wilcox Babcock & Wilcox Manufacturer Serial No.

620-0009-55-1 620-0009-55-2 State or National Province No. Board No.

N/A N-127 N/A N-128 Note:

Supplemental sheets in form of lists, sketches, or drawings may be used provided (1) size is 81/2 in. x 11 in., (2) information in items 1 through 6 on this data report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. -

FORM NIS-1 (Back)

8.

Examination Dates:

May 20, 2000 TO December 14, 2001

9.

Inspection Period Identification:

10.

Inspection Interval Identification:

11.

Applicable Edition of Section XI:

12.

Date/Revision of Inspection Plan:

Second Period (3d outage of second period)

Third Interval 1989 Addenda None Tech Spec 5.5.10 Steam Generator, 12/15/00 Revision

13. Abstract of Examinations and Test. Reference attached Steam Generator In-service Inspection Summary Report.
14. Abstract of Results of Examination and Tests. Reference attached Steam Generator In-service Inspection Summarv ReDort.
15. Abstract of Corrective Measures. Reference attached Steam Generator In-service Inspection Summary Report.

We certify that a) the statements made in this report are correct b) the examinations and tests meet the Inspection Plan as required by the ASME Code, Section Xl, and c) corrective measures taken conform to the rules of the ASME Code,Section XI.

Certificate of Authorization No. (if applicable)

Date

//o2 9 20 02 Signed N/A Expiration Date N/A Duke Energy Corp.

By LW 44 Owner U

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Province of South Carolina employed by *The HSBI&I Co. of Ha.4ktfOCT. have inspected the components described in this Owner's Report during the period S -

- a-Or' 0

to a - a b - a 0 2.

zi

, and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in the Owner's Report in accordance with the Inspection Plan and as required by the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, test, and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection 2

7.

4 Commissions 6,A 3 So AlI C

Inspector's Signature National Board, State, Province, and Endorsements Date a -

a L3 20 02

  • The Hartford Steam Boiler Inspection & Insurance Co.

200 Ashford Center North Suite 300 Atlanta, GA. 30338

Attachment to Form NIS-1 Steam Generator In-service Inspection Summary Report Oconee Nuclear Station Unit 3 - 2001 Outage EOC-19 Steam Generator Tubing Surveillance 1.0 Introduction Eddy current examinations were performed on the 0.625" OD x 0.037" wall Inconel 600 tubing, Inconel 600 plugs and the sleeved portion of the tubes in steam generators "A" and "B" at the Oconee Nuclear Station Unit 3 during the November 2001 refueling outage ONS 3 EOC19.

This report is a summary of the eddy current results.

2.0 Technical Summary This section provides a technical summary of the eddy current examinations performed at Duke Energy's, Oconee Nuclear Station, Unit 3 EOC19.

The Inconel 600 tubing in the two Babcock and Wilcox once through steam generators (OTSG's) "A" and "B" were examined by various eddy current techniques. The tubing in the generators measures 0.625 inch nominal outside diameter with a 0.037 inch nominal wall thickness.

Personnel from Duke Engineering & Services, Framatome ANP (FRA-ANP), Zetec, MoreTech, and ANATEC performed the examinations during the 19th refueling outage.

A magnetic-bias bobbin coil examination was performed on 14,521 tubes in steam generator "A" and 14,845 tubes in steam generator "B". All in-service sleeves were examined with a bobbin coil probe. A single coil "plus-point" motorized rotating coil MRPC probe was used to examine sleeve upper and lower rolls. A single coil motorized rotating coil MRPC probe was used to perform the plug examination. Special Interest locations, upper tubesheet rolls and lower tubesheets were examined with two-coil MRPC8 probe.

A total of 108 tubes were de-plugged and examined in OTSG "A" and OTSG "B", 55 tubes in OTSG "A" and 53 tubes in OTSG "B". The 1-600 plugs were tested with a single coil motorized rotating coil MRPC5 probe prior to removal. A magnetic-bias bobbin coil examination was performed SG In-service Inspection Page I of 12 ONS 3 EOC-19 Summary Report

after the plug removal. Special interest locations were examined with two-coil MRPC probe.

2.1 Summary The following is summary of the results of the eddy current examinations for each generator.

OTSG A:

Eddy current examinations began on 11/13/01 @ 0400 and were completed on 11/26/01 @ 0600.

281 tubes were removed from service by plugging.

12 tubes were repaired using FRA-ANP "Re-rolling" process 14521 tubes were examined with a bobbin coil probe, does not include de-plugged tubes.

4 tubes were reported to have indications of 40% through-wall, (TW) or greater with the bobbin coil probe examination.

30 tubes were reported to have indications of 20-39% TW with the bobbin coil probe examination.

275 sleeves were examined with a bobbin coil probe.

275 sleeves were examined with the plus point coil MRPC probe at the upper and lower rolls.

230 tubes in the lane/wedge region were examined at the 015-tube support plate (TSP) and upper tubesheet secondary face (UTS) intersections with a 2-coil MRPC probe.

14276 Hot Leg Roll Transition (HLRT) rolls were examined with the plus point 2-coil MRPC probe.

2103 Lower Tube Sheets (LTS) were examined with the plus point 2-coil MRPCO probe.

2 Lower Tubesheet Manufacture Re-rolls were examined.

2116 tubes were examined for special interest (SI) using the 2-coil MRPC probe.

55 de-plugged tubes were examined with a bobbin coil probe.

47 de-plugged tubes were examined for special interest, (SI) using the 2-coil MRPC5 probe.

SG In-service Inspection Summary Report Page 2 of 12 ONS 3 EOC-19

OTSG B:

Eddy current examinations began on 11/13/01 @ 0900 and were completed on 11/26/01 @ 0900.

14 tubes were repaired using FRA-ANP "Re-rolling" process 182 tubes were removed from service by plugging.

14845 tubes were examined with a bobbin coil probe, does not include de-plugged tubes.

1 tube was reported to have indications of 40% or greater with the bobbin coil probe examination.

18 tubes were reported to have indications of 20-39% TW with the bobbin coil probe examination.

246 tubes with sleeves were examined with a bobbin coil probe.

246 tubes with sleeves were examined with the plus-point coil MRPCO probe at the upper and lower rolls.

226 tubes in the lane/wedge region were examined at the 015 TSP and UTS intersections with the 2-coil MRPC probe.

14599 HLRT rolls were examined with the plus point 2-coil MRPC probe.

2139 LTS were examined with the plus point 2-coil MRPC probe.

3 Lower Tubesheet Manufacture Re-rolls were examined.

1238 tubes were examined for special interest using the 2-coil MRPC probe.

53 de-plugged tubes were examined with a bobbin coil probe.

52 de-plugged tubes were examined for special interest (SI) using the 2-coil MRPCO probe.

2.2 Examinations The examination, equipment and personnel were in compliance with the requirements of the Duke Engineering & Services NDE Program Manual for In-service Inspection, the applicable Duke Power Co.

Technical Specifications, the ASME Boiler and Pressure Vessel Code Section Xl, 1989 Edition and industry standards. Analysis of the eddy current data was performed in accordance with the "Eddy Current Analysis Guidelines for Oconee Nuclear Station Unit 3, EOC-19.

The steam generator tubing examinations were performed by technicians qualified to Level II, or Level I under direct supervision of personnel qualified to Level II in accordance with Duke Engineering &

Services procedure NDE-B.

The data was evaluated by personnel qualified to a minimum of Level IIA in accordance with Duke Engineering & Services procedure NDE-B.

The examination and evaluation procedures used during the eddy current examinations SG In-service inspection Page 3 of 12 ONS 3 EOC-19 Summary Report

were approved by personnel qualified to Level IlIl in accordance with Duke Engineering & Services procedure NDE-B.

All inspection frequencies were generated using a Zetec MIZ-30 remote data acquisition unit.

The bobbin coil examinations were performed with.510 inch,.500 inch, and.480 inch diameter probes. The inspection frequencies used were 600, 400, 200 and 35 kHz operating in both differential and absolute modes.

A 400/200 kHz differential tube support plate suppression mix was used to enhance the detection of indications occurring at TSP intersections.

The sleeve examinations were performed with a.400 inch diameter bobbin coil probe. The inspection frequencies used were 400, 250, 150 and 75 kHz operating in the differential and absolute mode. A 400/150 kHz differential tube support plate suppression mix was used to enhance the detection of indications occurring at TSP intersections.

Sleeve roll expansions were inspected using a.400 inch diameter plus-point coil MRPC8 probe. The inspection frequencies used were 200, 120, 75 and 50 kHz operating in the differential mode.

The lane & wedge and special interest examinations were performed with.460 inch diameter 2-coil MRPC8 probes.

The inspection frequencies used were 300, 200, 100 and 15 kHz. A 300/100 kHz TSP suppression mix on the pancake coil was used to enhance the detection of indications occurring at TSP intersections.

Official results of the data analysis were recorded on optical disks and verified by two Eddy Current Data Management systems, Framatome Data Management System, (FDMS) and EddyNete Inspection Management System, (EIMS). These systems are used to check the data for invalid analysis entries, perform data sorting routines, ensure all the proper tubes were examined and to printout final data sheets.

Note: Attachment 1 contains a list of all three-letter codes and acronyms used throughout this report.

SG In-service Inspection Page 4 of 12 ONS 3 EOC-19 Summary Report

2.3 Areas of Concern In OTSG's, certain modes of degradation have been identified in specific regions of the generator.

Eddy current examinations cannot, in all cases, determine the actual cause of damage.

The signal recorded during the eddy current examination can be used to estimate the physical size of any tube damage detected (i.e., penetration into the wall, axial extent), however, the actual type of degradation and its cause can only be determined by tube removal and metallurgical studies.

a) Impingement Erosion - An erosion/corrosion type of discontinuity occurring form the flow of secondary side water with contaminants or debris entrapped in the secondary side fluid stream.

b) High Cycle Fatigue - OD circumferential cracking normally occurring in the vicinity of the 15th TSP or upper tubesheet secondary face UTS in the open lane & wedge region.

The initiating mechanism for high-cycle fatigue is believed to be a combination of surface damage from corrosion, fretting and high crossflow velocities.

c) Wear - Wear fretting occurs at TSP intersections in tubes near the periphery or outermost rows in the generator.

This damage mechanism is caused by flow-induced mechanical vibrations, which are influenced by design parameters, environmental and operating conditions.

d) Inter-granular Stress Corrosion Cracking (IGSCC) - Tube pull results have confirmed the presence of axially oriented inter-granular stress corrosion cracking. IGSCC has been primarily confirmed at locations from the 007TSP and higher. This problem is not associated with a particular region of the steam generator. Indications are characterized as axial and may display a multiple intermittent response over several inches. IGSCC has been confirmed in the sludge pile on the lower tubesheet and noted at the upper tubesheet and dented TSP locations.

e) Inside Diameter Inter-granular Attack (ID IGA) - Numerous indications indicative of ID IGA have been reported in the upper tubesheet of Oconee Unit 1, SG B. This mechanism is not believed to be active and is believed to have been initiated as a result of the manufacturing process and unique to SG B of Unit 1.

SG In-service Inspection Page 5 of 12 ONS 3 EOC-19 Summary Report

f) Primary Water Stress Corrosion Cracking (PWSCC) - PWSCC has been confirmed through tube pulls in the upper tube end (Hot Leg) roll expansion. Indications are generally axially oriented and located in the transition or the expanded region.

Plugs and sleeves are also susceptible to this type of damage mechanism.

g) Inter-granular Attack (IGA) - OD initiated IGA has been detected at the upper spans and within the upper tubesheet crevice, lower tubesheet crevice and first span pit-like IGA.

2.4 Results A number of indications within both generators were given a non-quantifiable (NQI) code in the percent through-wall column. This code was used during the bobbin examinations for indications where an accurate depth determination could not be made.

Additionally, a number of indications within both generators were reported as an Absolute Drift Indication (ADI) in the percent through-wall column. These are indications of degradation that could not be accurately quantified on differential channels.

2.5 OTSG A and B results: details the results of the various eddy current examinations performed in OTSG A and OTSG B. A total of two hundred and eighty-one (281) tubes were removed from service in OTSG A and one hundred fifty four (154) tubes in OTSG B. These tubes were removed from service based on the results of the following eddy current examinations.

Refer to Data Management Report for results and specific tube numbers for tubes plugged during the outage.

SG In-service Inspection Summary Report Page 6 of 12 ONS 3 EOC-19 DESCRI PTION CODE DESCRIPTION ADI Absolute Drift Indication AXI Axial Indication FTI Framatome Technologies DRS Distorted Roll Signal DWI Dent With Indication HLRT Hot Leg Roll Transition IDI Inside Diameter Indication LTP Lower Tubesheet Primary face LTS Lower Tubesheet Secondary face MAI Multiple Axial Indication MCI Multiple Circumferential Indication MMI Mix Mode Indication MVI Multiple Volumetric Indication MRPC Motorized Rotating Pancake Coil NDD No Degradation Detected NQI Non-Quantifiable Indication OD Outside Diameter ODI Outside Diameter Indication OTSG Once-Through Steam Generator PVN Permeability PWSCC Primary Water Stress-Corrosion Cracking QA Quality Assurance RBD Retest - Bad Data RIC Retest - Incomplete RNC Retest - Number Check SAI Single Axial Indication SCI Single Circumferential Indication SVI Single Volumetric Indication TEA Tube End Anomalies TSP Tube Support Plate TW Through Wall TWD Through Wall Depth UTP Upper Tubesheet Primary face UTS Upper Tubesheet Secondary face VOL Volumetric indication SG In-service Inspection Page 7 of 12 ONS 3 EOC-19 Summary Report ONS 3 EOC 19 OTSG A and B Eddy Current Results.

Bobbin Examinations Steam Generator "A"

. Steam Generator "B" Tubes Tested: 14,521 Tubes Tested: 14,845 Tubes With Indications Number of Indications II Tubes With Indications Number of Indications TWD > 40%

4 4

1 1

TWD 20-39%

30 32 18 19 TWD < 20%

24 25 19 19 ADI's 31 34 17 20 NQI,s 1493 1901 972 1138 DWI's 4

4 2

3 Bobbin Examinations on de-plugged tubes Steam Generator "A" Steam Generator "B" Tubes Tested: 55 Tubes Tested: 53 Tubes With Number of Tubes With Number of Indications Indications Indications Indications TWD > 40%

20 22 14 16 TWD 20-39%

12 14 10 11 TWD < 20%

4 4

2 2

ADI's 0

0 2

2 NQI,s 37 60 34 58 DWI's 0

0 0

0 Plug Examinations Inconel 600 Steam Generator "A" Steam Generator "B" H/L Plugs Tested: 34 HIL Plugs Tested: 29 C/L Plugs Tested: 67 CJL Plugs Tested: 44 H/L C/L H/L C/L Plugs/Indications Plugs/Indications Plugs/Indications Plugs/Indications SAI's 8/8 0

4/6 0

MAI's 5/5 1/1 3/3 0

SCI,s 0

0 0

0 MCI'S 0

0 0

0 PVN's 0

0 0

0 SVI'S 0

0 0

0 MVI's 0

0

.0 0

SG In-service Inspection Summary Report Page 8 of 12 ONS 3 EOC-19

Lane and Wedge Examinations Steam Generator "A" Tubes Tested: 230 Steam Generator "B" Tubes Tested: 226 U

Tubes With Indications Number of Indications Tubes With Indications Number of Indications Wear 8

8 0

0 VOL's 0

0 0

0 NQI's 0

0 0

0 SAI's 2

2 1

1 MAI's 0

0 1

1 SCI's 0

0 1

1 MCI's 0

0 0

0 MMI's 0

0 0

0 SVI's 11 0

0 MVI's 0

0 0

0 Sleeve Roll Examinations Steam Generator "A" Steam Generator "B" Tubes Tested: 275 Tubes Tested: 246 Sleeves Number of Sleeves With Number of With Indications Indications Indications Indications DRS's 62 70 36 38 VOL's 2

2 4

5 NQI's 0

0 0

0 SAI's 1

1 1

1 MAI's 1

1 0

0 SCI's 0

0 0

0 MCI's 0

0 0

0 MMI's 0

0 0

0 SVI's 0

0 0

0 MVI's 0

0 0

0 PVN's 1

1 3

3 SG In-service Inspection Summary Report Page 9 of 12 ONS 3 EOC-19

UTS Roll Examinations Steam Generator "A" Steam Generator "B" Tubes Tested: 14,246 Tubes Tested: 14,599 1II r..,.......

Rolls With Indications Number of Indications Rolls With Indications Number of Indications VOL's 3

4 16 16 NQI's 0

0 0

0 SAI's 14 14 22 22 MAI's 0

0 10 12 SCI's 1

2 3

3 MCI's 0

0 0

0 MMI's 0

0 0

0 SVI's 0

0 0

0 MVI's 0

0 0

0 TEA's 228 229 180 180 UTS Re-Roll Examinations Steam Generator "A" Steam Generator "B" Tubes Re-Rolled: 12 Tubes Re-Rolled: 14 Re-Rolls With Number of Re-Rolls With Number of Indications Indications Indications Indications VOL's 0

0 0

0 NQI's 0

0 0

0 SAI's 0

0 0

0 MAI's 0

0 0

0 SCI's 0

0 0

0 MCI's 0

0 0

0 MMI's 0

0 0

0 SVI's 0

0 0

0 MVI's 0

0 0

0 SG In-service Inspection Summary Report Page 10 of 12 ONS 3 EOC-19

Special Interest Examinations Steam Generator "A" Tubes Tested: 2116 Locations Tested 2701 Steam Generator "B" Tubes Tested: 1238 Locations Tested 1508

-II Tubes With Indications Number of Indications Tubes With Indications Number of Indications Wear > 40%

0 0

0 0

Wear 20-39%

5 5

4 4

Wear < 20%

302 353 211 225 VOL's 479 544 420 469 NQI's 0

0 0

0 SAI's 97 343 21 39 MAI's 4

4 0

0 SCI's 3

3 2

2 MCI's 0

0 0

0 MMI's 0

0 0

0 SVI's 1

1 3

3 MVI's 0

0 0

0 Special Interest Examinations, de-plugged tubes..

Steam Generator "A" Steam Generator "B" Tubes Tested: 47 Tubes Tested: 52 Locations Tested 84 Locations Tested 83 Tubes With Number of Tubes With Number of Indications Indications Indications Indications Wear > 40%

0 0

1 1

Wear 20-39%

5 5

4 5

Wear < 20%

17 24 9

9 VOL's 20 36 10 13 NQI's 0

0 0

0 SAI's 3

13 3

3 MAI's 0

0 1

1 SCI's 0

0 0

0 MCI's 0

0 0

0 MMI's 0

0 0

0 SVI's 20 27 38 50 MVI's 0

0 0

0 SG In-service Inspection Summary Report Page I I of 12 ONS 3 EOC-19

Lower Tubesheet Kidney Region Examinations Steam Generator "A" Steam Generator "B" Tubes Tested: 2103 Tubes Tested: 2139 Tubes With Number of Tubes With Number of Indications Indications Indications Indications 0

0 5

5 o

0 0

0 o

0 0

0 o

0 0

0 o

0 0

0 o

0 0

0 o

0 0

0 O

O 0

0 O

0 0

O Lower Tubesheet Re-Roll Examinations Steam Generator "A" Steam Generator "B" Re-Rolls Tested: 2 Re-Rolls Tested: 3

_I Tubes With Indications Number of Indications Tubes With Indications Number of Indications VOL's 0

0 0

0 NQI's 0

0 0

0 SAI's 0

0 0

0 MAI's 0

0 0

0 SCI's 0

0 0

0 MCI's 0

0 0

0 MMI's 0

0 0

0 SVI's 0

0 0

0 MVI's 0

0 O

0 SG In-service Inspection Summary Report Page 12 of 12 ONS 3 EOC-19