ML020300534
| ML020300534 | |
| Person / Time | |
|---|---|
| Site: | Oyster Creek (DPR-016) |
| Issue date: | 01/23/2002 |
| From: | Office of Nuclear Reactor Regulation |
| To: | |
| References | |
| Download: ML020300534 (2) | |
Text
5.3 AUXILIARY EOUIPMENT 5.3.1 Fuel Storage A.
The fuel storage facilities are designed and shall be maintained with a K-effective equivalent to less than or equal to 0.95 including all calculational uncertainties.
B.
Deleted C.
Deleted D.
The temperature of the water in the spent fuel storage pool, measured at or near the surface, shall not exceed 125°F.
E.
The maximum amount of spent fuel assemblies stored in the spent fuel storage pool shall be 3035.
OYSTER CREEK 5.3-1 Amendment No.: 22, 76, 77, 121, 179, 187, 215, 223
BASIS The specification of a K-effective less than or equal to 0.95 in fuel storage facilities assures an ample margin from criticality. This limit applies to unirradiated fuel in both the dry storage vault and the spent fuel racks as well as irradiated fuel in the spent fuel racks. Criticality analyses were performed on the poison racks to ensure that a K-effective of 0.95 would not be exceeded. The analyses took credit for burnable poisons in the fuel and included manufacturing tolerances and uncertainties as described in Section 9.1 of the FSAR. Calculational uncertainties described in 5.3.1.A are explicitly defined in FSAR Section 9.1.2.3.9. Any fuel stored in the fuel storage facilities shall be bounded by the analyses in these reference documents.
The effects of a dropped fuel bundle onto stored fuel in the spent fuel storage facility have been analyzed.
This analysis shows that the fuel bundle drop would not cause doses resulting from ruptured fuel pins that exceed 10 CFR 100 limits (1,2,3).
Detailed structural analysis of the spent fuel pool was performed using loads resulting from the dead weight of the structural elements, the building loads, hydrostatic loads from the pool water, the weight of fuel and racks stored in the pool, seismic loads, and loads due to thermal gradients in the pool floor and the walls. Thermal gradients result in two loading conditions: normal operating and the accident conditions with the loss of spent fuel pool cooling. For the normal condition, the reactor building air temperature was assumed to vary between 65°F and 1 10°F while the pool water temperature varied between 85°F and 1250F. The most severe loading from the normal operating thermal gradient results with reactor building air temperatures at 65°F and the water temperature at 125°F. Air temperature measurements made during all phases of plant operation in the shutdown heat exchanger room, which is directly beneath part of the spent fuel pool floor slab, show that 650F is the appropriate minimum air temperature. The spent fuel pool water temperature will alarm control room before the water temperature reaches 120°F.
Results of the structural analysis show that the pool structure is structurally adequate for the loadings associated with normal operation and postulated accidents (5) (6). The floor framing was also found to be capable of withstanding the steady state thermal gradient conditions with the pool water temperature at
-150°F without exceeding ACI Code requirements.' The walls are also capable of operation at a steady state condition with the pool water temperature at 140'F (5).
Since the cooled fuel pool water returns at the bottdm of the pool and the heated water is removed from the surface, the average of the surfa :e temperature and the fuel pool cooling return water is an appropriate estimate of the average bulk temperature; alternately t~.e pool surface temperature could be conservatively used.
References I.
Amendment No. 78 to FDSAR (Section 7)
- 2.
Supplement No. I to Amendment No. 78 to the FDSAR (Question 12)
- 3.
Supplement No. 1 to Amendment 78 of the FDSAR (Question 40)
- 4.
Deleted
- 5.
Revision No. 1 to Addendum 2 to Supplement No. 1 to Amendment No. 78 of FDSAR (Questions 5 and 10)
- 6.
FDSAR Amendment No. 79
- 7.
Deleted
- 8.
Holtec Report HI-981983, Revision 4 Amendment No.: 121, 179, 187, 215, 223 OYSTER CREEK 5.3-2